librenms/mibs/raisecom/ROSMGMT-OPTICAL-TRANSCEIVER-MIB
Vitali Kari 9126e0f00a
new device os Raisecom Router OS (ROAP) (#12361)
* new device os Raisecom Router OS (ROAP)
tried to add that as existing raisecom os but ended in new os, because they use a
new MIB base for Router OS and newer devices.

* add sensors
2021-01-04 00:39:35 +01:00

2252 lines
82 KiB
Plaintext

--MibName=ROSMGMT-OPTICAL-TRANSCEIVER-MIB.mib
-- *****************************************************************
-- ROSMGMT-OPTICAL-TRANSCEIVER-MIB.mib
--
-- Copyright(c) 2003-2005 by RAISECOM TECH, Ltd.
-- All rights reserved.
-- *****************************************************************
-- *****************************************************************
-- Modi Report£ºFormat: <number>, <time>, <author>, <desc>
-- 01, 20110623, yangzhognhong, change the value of the node raisecomOpticalTransceiverMediaType
-- for SFP+ development
--
-- *****************************************************************
ROSMGMT-OPTICAL-TRANSCEIVER-MIB DEFINITIONS ::= BEGIN
IMPORTS
Integer32, Unsigned32,
MODULE-IDENTITY,
NOTIFICATION-TYPE,
OBJECT-TYPE,TimeTicks FROM SNMPv2-SMI
rosMgmt FROM RAISECOM-BASE-MIB
TEXTUAL-CONVENTION,
TruthValue FROM SNMPv2-TC
-- OBJECT-GROUP FROM SNMPv2-CONF
ifIndex FROM IF-MIB;
-- raisecomNotificationLocation FROM RAISECOM-COMMON-MANAGEMENT-MIB
-- ClearVar FROM SWITCH-TC;
rosMgmtOpticalTransceiver MODULE-IDENTITY
LAST-UPDATED "202004160000Z"
ORGANIZATION "Raisecom, Inc."
CONTACT-INFO
" Raise Systems
Postal: Beijing,
China
Tel: 86-010-82884499
E-mail: chenyu@raisecom.com"
DESCRIPTION
"This MIB module defines objects to monitor optical
characteristics on the optical interfaces in a network element. "
REVISION "202004160000Z"
DESCRIPTION
"The initial revision of this MIB."
::={ rosMgmt 18 }
rosMgmtOpticalTransceiverNotifications OBJECT IDENTIFIER ::= { rosMgmtOpticalTransceiver 0 }
rosMgmtOpticalTransceiverObjects OBJECT IDENTIFIER ::= { rosMgmtOpticalTransceiver 1 }
rosMgmtOpticalTransceiverConformance OBJECT IDENTIFIER ::= { rosMgmtOpticalTransceiver 2 }
rosMgmtOpticalTransceiverAbsentTrap NOTIFICATION-TYPE
OBJECTS { rosMgmtOpticalTransceiverHwInfoAbsStatus,
rosMgmtOpticalTransceiverSpecificationCheckStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module is removed from the device.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ rosMgmtOpticalTransceiverNotifications 1 }
rosMgmtOpticalTransceiverPresentTrap NOTIFICATION-TYPE
OBJECTS { rosMgmtOpticalTransceiverHwInfoAbsStatus,
rosMgmtOpticalTransceiverSpecificationCheckStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module is plugged into the device.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ rosMgmtOpticalTransceiverNotifications 2 }
rosMgmtOpticalTransceiverNRAlarmTrap NOTIFICATION-TYPE
OBJECTS { rosMgmtOpticalTransceiverHwInfoNRStatus }
STATUS current
DESCRIPTION
"This notification is sent when the transmitted or received data of optical module is invalid.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ rosMgmtOpticalTransceiverNotifications 3 }
rosMgmtOpticalTransceiverNRNormalTrap NOTIFICATION-TYPE
OBJECTS { rosMgmtOpticalTransceiverHwInfoNRStatus }
STATUS current
DESCRIPTION
"This notification is sent when the transmitted or received data of optical module is valid.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ rosMgmtOpticalTransceiverNotifications 4 }
rosMgmtOpticalTransceiverRxLosAlarmTrap NOTIFICATION-TYPE
OBJECTS { rosMgmtOpticalTransceiverHwInfoRxLosStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module receiving signal is lost.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ rosMgmtOpticalTransceiverNotifications 5 }
rosMgmtOpticalTransceiverRxLosNormaTrap NOTIFICATION-TYPE
OBJECTS {rosMgmtOpticalTransceiverHwInfoRxLosStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module receiving signal is back to normal.
This notification may be suppressed under the following
conditions:
- depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
"
::={ rosMgmtOpticalTransceiverNotifications 6 }
--raisecomOpticalTransceiverCheckPwdFailureTrap NOTIFICATION-TYPE
-- STATUS current
-- DESCRIPTION
-- "This notification is sent when the optical module password checking is failed.
-- This notification may be suppressed under the following
-- conditions:
-- - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
-- "
-- ::={ rosMgmtOpticalTransceiverNotifications 7 }
--raisecomOpticalTransceiverCheckPwdSucceedTrap NOTIFICATION-TYPE
-- STATUS current
-- DESCRIPTION
-- "This notification is sent when the optical module password cheching is successful.
-- This notification may be suppressed under the following
-- conditions:
-- - depending on the value of the raisecomOpticalNotifyEnable and raisecomOpticalPortNotifyEnable objects.
-- "
-- ::={ rosMgmtOpticalTransceiverNotifications 8 }
rosMgmtOpticalTransceiverParamAlarmTrap NOTIFICATION-TYPE
OBJECTS { rosMgmtOpticalTransceiverParameterValue,
rosMgmtOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module parameter value increase to above
the high alarm threshold or dicrease to under the low alarm threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the rosMgmtOpticalNotifyEnable and rosMgmtOpticalPortNotifyEnable objects.
"
::={ rosMgmtOpticalTransceiverNotifications 7 }
rosMgmtOpticalTransceiverParamAlarmNormalTrap NOTIFICATION-TYPE
OBJECTS { rosMgmtOpticalTransceiverParameterValue,
rosMgmtOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module parameter value dicrease to
under the high alarm threshold or increase to above the low alarm threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the rosMgmtOpticalNotifyEnable and rosMgmtOpticalPortNotifyEnable objects.
"
::={ rosMgmtOpticalTransceiverNotifications 8 }
rosMgmtOpticalTransceiverParamWarningTrap NOTIFICATION-TYPE
OBJECTS { rosMgmtOpticalTransceiverParameterValue,
rosMgmtOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module parameter value increase to above
the high warning threshold or dicrease to under the low warning threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the rosMgmtOpticalNotifyEnable and rosMgmtOpticalPortNotifyEnable objects.
"
::={ rosMgmtOpticalTransceiverNotifications 9 }
rosMgmtOpticalTransceiverParamWarningNormalTrap NOTIFICATION-TYPE
OBJECTS { rosMgmtOpticalTransceiverParameterValue,
rosMgmtOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module parameter value dicrease to
under the high warning threshold or increase to above the low warning threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the rosMgmtOpticalNotifyEnable and rosMgmtOpticalPortNotifyEnable objects.
"
::={ rosMgmtOpticalTransceiverNotifications 10 }
rosMgmtOpticalTransceiverLaserBackLightAlarmTrap NOTIFICATION-TYPE
OBJECTS { rosMgmtOpticalTransceiverParameterValue,
rosMgmtOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module password cheching is successful.
This notification may be suppressed under the following
conditions:
- depending on the value of the rosMgmtOpticalNotifyEnable and rosMgmtOpticalPortNotifyEnable objects.
"
::={ rosMgmtOpticalTransceiverNotifications 11 }
rosMgmtOpticalTransceiverLaserBackLightAlarmNormalTrap NOTIFICATION-TYPE
OBJECTS { rosMgmtOpticalTransceiverParameterValue,
rosMgmtOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module password cheching is successful.
This notification may be suppressed under the following
conditions:
- depending on the value of the rosMgmtOpticalNotifyEnable and rosMgmtOpticalPortNotifyEnable objects.
"
::={ rosMgmtOpticalTransceiverNotifications 12 }
rosMgmtOpticalTransceiverLaserLifeAlarmTrap NOTIFICATION-TYPE
OBJECTS { rosMgmtOpticalTransceiverParameterValue,
rosMgmtOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module password cheching is successful.
This notification may be suppressed under the following
conditions:
- depending on the value of the rosMgmtOpticalNotifyEnable and rosMgmtOpticalPortNotifyEnable objects.
"
::={ rosMgmtOpticalTransceiverNotifications 13 }
rosMgmtOpticalTransceiverLaserLifeAlarmNormalTrap NOTIFICATION-TYPE
OBJECTS { rosMgmtOpticalTransceiverParameterValue,
rosMgmtOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module password cheching is successful.
This notification may be suppressed under the following
conditions:
- depending on the value of the rosMgmtOpticalNotifyEnable and rosMgmtOpticalPortNotifyEnable objects.
"
::={ rosMgmtOpticalTransceiverNotifications 14 }
rosMgmtOpticalTransceiverParamLowAlarmTrap NOTIFICATION-TYPE
OBJECTS { rosMgmtOpticalTransceiverParameterValue,
rosMgmtOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module parameter value increase to above
the high alarm threshold or dicrease to under the low alarm threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the rosMgmtOpticalNotifyEnable and rosMgmtOpticalPortNotifyEnable objects.
"
::={ rosMgmtOpticalTransceiverNotifications 15 }
rosMgmtOpticalTransceiverParamLowAlarmNormalTrap NOTIFICATION-TYPE
OBJECTS { rosMgmtOpticalTransceiverParameterValue,
rosMgmtOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module parameter value increase to above
the high alarm threshold or dicrease to under the low alarm threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the rosMgmtOpticalNotifyEnable and rosMgmtOpticalPortNotifyEnable objects.
"
::={ rosMgmtOpticalTransceiverNotifications 16 }
rosMgmtOpticalTransceiverParamLowWarningTrap NOTIFICATION-TYPE
OBJECTS { rosMgmtOpticalTransceiverParameterValue,
rosMgmtOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module parameter value increase to above
the high alarm threshold or dicrease to under the low alarm threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the rosMgmtOpticalNotifyEnable and rosMgmtOpticalPortNotifyEnable objects.
"
::={ rosMgmtOpticalTransceiverNotifications 17 }
rosMgmtOpticalTransceiverParamLowWarningNormalTrap NOTIFICATION-TYPE
OBJECTS { rosMgmtOpticalTransceiverParameterValue,
rosMgmtOpticalTransceiverParamAlarmStatus }
STATUS current
DESCRIPTION
"This notification is sent when the optical module parameter value increase to above
the high alarm threshold or dicrease to under the low alarm threshold.
This notification may be suppressed under the following
conditions:
- depending on the value of the rosMgmtOpticalNotifyEnable and rosMgmtOpticalPortNotifyEnable objects.
"
::={ rosMgmtOpticalTransceiverNotifications 18 }
rosMgmtOpticalTransceiverTxFaultTrap NOTIFICATION-TYPE
OBJECTS { rosMgmtOpticalTransceiverTxFaultStatus }
STATUS current
DESCRIPTION
"This notification is sent when the SFP optical module occures Tx-fault signal.
This notification may be suppressed under the following
conditions:
- depending on the value of the rosMgmtOpticalNotifyEnable and rosMgmtOpticalPortNotifyEnable objects.
"
::={ rosMgmtOpticalTransceiverNotifications 19 }
rosMgmtOpticalTransceiverTxNormalTrap NOTIFICATION-TYPE
OBJECTS { rosMgmtOpticalTransceiverTxFaultStatus }
STATUS current
DESCRIPTION
"This notification is sent when the SFP optical module cancels the Tx-fault signal.
This notification may be suppressed under the following
conditions:
- depending on the value of the rosMgmtOpticalNotifyEnable and rosMgmtOpticalPortNotifyEnable objects.
"
::={ rosMgmtOpticalTransceiverNotifications 20 }
-- Textual Conventions
EnableVar ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"enable or disable a function."
SYNTAX INTEGER {
enable(1),
disable(2)
}
OpticalParameterType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This value indicates the optical parameter that is
being monitored. Valid values are -OpticalParameterType
transceiverTemperature(1) :transceiver temperature
txbiasCurrent(2) :TX bias current
txPower(3) :TX output power
rxPower(4) :RX received optical power
laserTemperature(5) :laser temperature
p5V0supplyVoltage(6) :+5V supply voltage
p3V3supplyVoltage(7) :+3.3V supply voltage
p1V8supplyVoltage(8) :+1.8V supply voltage
n5V2supplyVoltage(9) :-5.2V supply voltage
apdBiasVoltage(10) :APD bias voltage
p5V0supplyCurrent(11) :+5V supply currnet
p3V3supplyCurrent(12) :+3.3V supply currnet
p1V8supplyCurrent(13) :+1.8V supply currnet
n5V2supplyCurrent(14) :-5.2V supply currnet
tecCurrent(15) :TEC currnet
laserWavelength(16) :laser wavelength
"
SYNTAX INTEGER {
transceiverTemperature (1),
txbiasCurrent (2),
txPower (3),
rxPower (4),
laserTemperature(5),
p5V0supplyVoltage(6),
p3V3supplyVoltage(7),
p1V8supplyVoltage(8),
n5V2supplyVoltage(9),
apdBiasVoltage(10),
p5V0supplyCurrent(11),
p3V3supplyCurrent(12),
p1V8supplyCurrent(13),
n5V2supplyCurrent(14),
tecCurrent(15),
laserWavelength(16)
}
OpticalParameterValue ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d-2"
STATUS current
DESCRIPTION
"The value of the optical parameter that is being monitored.
The range of values varies depending on the type of optical parameter being monitored,
as identified by a corresponding object with syntax OpticalParameterType.
When the optical parameter being monitored is 'XXTemperature',the supported range
is from -40000 to 125000, in units of 1/1000 degrees centigrade.
Example: A value of 23500 represents a temperature reading of 23.5 degrees C.
The temperature is shown in unit of degrees centigrade, and the precision is 0.1.
When the optical parameter being monitored is 'txbiasCurrent',the supported range
is from 0 to 131000, in units of 1/1000 mA.
Example: A value of 1000 represents a TX bias current reading of 1.0mA.
The 'txbiasCurrent'is shown in unit of mA, and the precision is 0.1.
When the optical parameter being monitored is 'txPower',the supported range
is from -40000 to 8200, in units of 1/1000 dbm.
Example: A value of 77800 represents a TX output power reading of 7.78 dBm.
The 'txPower' is shown in unit of dBm, and the precision is 0.1.
When the optical parameter being monitored is 'rxPower',the supported range
is from -40000 to 8200, in units of 1/1000 dbm.
Example: A value of 7780 represents a RX received optical power reading of 7.78 dBm.
The 'rxPower' is shown in unit of dBm, and the precision is 0.1.
When the optical parameter being monitored is 'XXsupplyVoltage',the supported range
is from 0 to 6550, in units of 1/1000 V.
Example: A value of 6000 represents a XX supply Voltage eading of 6.00V.
The 'XXsupplyVoltage'is shown in unit of V, and the precision is 0.01.
When the optical parameter being monitored is 'apdBiasVoltage,the supported range
is from 0 to 655300 , in units of 1/1000 V .
Example: A value of 600000 represents a APD BiasVoltage reading of 600.0V.
The 'apdBiasVoltage' is shown in unit of V, and the precision is 0.1.
When the optical parameter being monitored is 'XXsupplyCurrent',the supported range
is from 0 to 6553600, in units of 1/1000 mA .
Example: A value of 6000000 represents a XX supply current reading of 6000.0mA.
The 'XXsupplyCurrent' is shown in unit of mA, and the precision is 0.1.
When the optical parameter being monitored is 'tecCurrent',the supported range
is from 0 to 6553600, in units of 1/1000 mA .
Example: A value of 6000000 represents a TEC Current reading of 6000.0mA.
The 'tecCurrent' is shown in unit of mA, and the precision is 0.1.
When the optical parameter being monitored is 'laserWavelength,the supported range
is from 0 to 3276750, in units of 1/1000 nm .
Example: A value of 3000000 represents a laser wavelength reading of 3000.0nm.
The 'laserWavelength'is shown in unit of nm, and the precision is 0.01.
"
SYNTAX Integer32 (-1000000 | -40000..6553600)
OpticalPMPeriod ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This value indicates the time period over which performance
monitoring data has been collected."
SYNTAX INTEGER {
fifteenMin(1),
twentyFourHour(2)
}
-- MIB Scalar Group Definitions
rosMgmtOpticalTransceiverScalarGroup OBJECT IDENTIFIER ::=
{rosMgmtOpticalTransceiverObjects 1 }
rosMgmtOpticalTransceiverNotifyEnable OBJECT-TYPE
SYNTAX EnableVar
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the generation of device notifications,
enable or disable.
this object belongs to xfp and sfp.
"
DEFVAL { disable }
::={ rosMgmtOpticalTransceiverScalarGroup 1 }
rosMgmtOpticalTransceiverDDMEnable OBJECT-TYPE
SYNTAX EnableVar
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable or disable digitaldiagnotic on the device.
this object belongs to xfp and sfp.
"
DEFVAL { disable}
::={ rosMgmtOpticalTransceiverScalarGroup 2 }
rosMgmtOpticalTransceiverCheckPwdEnable OBJECT-TYPE
SYNTAX EnableVar
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the status of password checking on the device,
enable or disable.
this object belongs to xfp.
"
DEFVAL { disable}
::={ rosMgmtOpticalTransceiverScalarGroup 3 }
rosMgmtOpticalTransceiverPollInterval OBJECT-TYPE
SYNTAX Integer32 (5..15)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the value of poll-interval on the device.
this object belongs to xfp and sfp.
"
::={ rosMgmtOpticalTransceiverScalarGroup 4 }
rosMgmtOpticalTransceiverCRCCheckEnable OBJECT-TYPE
SYNTAX EnableVar
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the status of crc checking on the device,
enable or disable.
this object belongs to sfp and xfp.
"
DEFVAL { disable}
::={ rosMgmtOpticalTransceiverScalarGroup 5 }
-- MIB Object Definitions
rosMgmtOpticalTransceiverCfgObjects OBJECT IDENTIFIER ::=
{rosMgmtOpticalTransceiverObjects 2 }
-- groups in this MIB module
rosMgmtOpticalTransceiverInfoGroup OBJECT IDENTIFIER ::=
{rosMgmtOpticalTransceiverCfgObjects 1 }
rosMgmtOpticalTransceiverDDMGroup OBJECT IDENTIFIER ::=
{rosMgmtOpticalTransceiverCfgObjects 2 }
rosMgmtOpticalTransceiverPMGroup OBJECT IDENTIFIER ::=
{rosMgmtOpticalTransceiverCfgObjects 3 }
rosMgmtOpticalTransceiverStatusGroup OBJECT IDENTIFIER ::=
{rosMgmtOpticalTransceiverCfgObjects 4 }
-- rosMgmtOpticalTransceiverInfoTable
rosMgmtOpticalTransceiverInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF RosMgmtOpticalTransceiverInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Trancetver information Table."
::= { rosMgmtOpticalTransceiverInfoGroup 1 }
rosMgmtOpticalTransceiverInfoEntry OBJECT-TYPE
SYNTAX RosMgmtOpticalTransceiverInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the rosMgmtOpticalTransceiverInfoTable."
INDEX { ifIndex }
::={ rosMgmtOpticalTransceiverInfoTable 1 }
RosMgmtOpticalTransceiverInfoEntry ::= SEQUENCE {
rosMgmtOpticalTransceiverType INTEGER,
rosMgmtOpticalTransceiverConnectorType INTEGER,
rosMgmtOpticalTransceiverVendorName OCTET STRING,
rosMgmtOpticalTransceiverVendorPN OCTET STRING,
rosMgmtOpticalTransceiverVendorSN OCTET STRING,
rosMgmtOpticalTransceiverMediaType INTEGER,
rosMgmtOpticalTransceiverTransmissionDistance Integer32,
rosMgmtOpticalTransceiverAbility Unsigned32,
rosMgmtOpticalTransceiverDDM INTEGER,
rosMgmtOpticalTransceiverCalibrationType INTEGER,
rosMgmtOpticalTransceiverRSSI INTEGER,
rosMgmtOpticalTransceiverVendorRev OCTET STRING,
rosMgmtOpticalTransceiverBRMax Integer32,
rosMgmtOpticalTransceiverBRMin Integer32,
rosMgmtOpticalTransceiverWavelengthContrl INTEGER,
rosMgmtOpticalTransceiverWavelength Integer32,
rosMgmtOpticalTransceiverWaveTolerance Integer32,
rosMgmtOpticalTransceiverCompatibility OCTET STRING,
rosMgmtOpticalTransceiverPowerDissipation INTEGER,
rosMgmtOpticalTransceiverCDR INTEGER,
rosMgmtOpticalTransceiverRefClock INTEGER,
rosMgmtOpticalTransceiverTransmitterType INTEGER,
rosMgmtOpticalTransceiverCooled INTEGER,
rosMgmtOpticalTransceiverTunalbe INTEGER,
rosMgmtOpticalTransceiverDetectorType INTEGER,
rosMgmtOpticalTransceiverLineLoopBack INTEGER,
rosMgmtOpticalTransceiverXFILoopBack INTEGER,
rosMgmtOpticalTransceiverVps INTEGER,
rosMgmtOpticalTransceiverTxDis INTEGER,
rosMgmtOpticalTransceiverStandby INTEGER,
rosMgmtOpticalTransceiverInVpsLowPower INTEGER,
rosMgmtOpticalTransceiverOutVpsLowPower INTEGER,
rosMgmtOpticalTransceiverFEC INTEGER,
rosMgmtOpticalTransceiverCMU INTEGER,
rosMgmtOpticalTransceiverBR INTEGER
}
rosMgmtOpticalTransceiverType OBJECT-TYPE
SYNTAX INTEGER{
unknown(1),
gbic(2),
soldered(3),
sfp(4),
xbi(5),
xenpak(6),
xfp(7),
xff(8),
xfpe(9),
xpak(10),
x2(11),
sfpj(12),
qsfp(14),
qsfp28(18)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the physical type of the transceiver,
such as xfp or sfp , and so on.
this object belongs to xfp and sfp.
"
::= { rosMgmtOpticalTransceiverInfoEntry 1 }
rosMgmtOpticalTransceiverConnectorType OBJECT-TYPE
SYNTAX INTEGER
{
unknown(1),
sc (2),
db9(3),
hssdc(4),
bnctnc(5),
fibercoaxialhead(6),
fiberjack(7),
lc(8),
mtrj(9),
mu(10),
sg(11),
fiberpigtail(12),
mpoparalleloptic(13),
hssdcII (14),
copper (15),
rj45 (16)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the connector type of the transceiver,
unknown, sc, db9, hssdc, bnc_tnc, fiber_coaxial_head, fiber_outlet,
lc, mt_rj, mu, sg, fiber_pigtail, mpo_parallel_optic , hssdcII,
copper, rj45.
this object belongs to xfp and sfp.
"
::= { rosMgmtOpticalTransceiverInfoEntry 2 }
rosMgmtOpticalTransceiverVendorName OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Vendor name of the interface.
this object belongs to xfp and sfp.
"
::= { rosMgmtOpticalTransceiverInfoEntry 3 }
rosMgmtOpticalTransceiverVendorPN OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Vendor part number of the interface.
this object belongs to xfp and sfp.
"
::= { rosMgmtOpticalTransceiverInfoEntry 4 }
rosMgmtOpticalTransceiverVendorSN OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Vendor serial number of the interface.
this object belongs to xfp and sfp.
"
::= { rosMgmtOpticalTransceiverInfoEntry 5 }
rosMgmtOpticalTransceiverMediaType OBJECT-TYPE
SYNTAX INTEGER
{
singlemode(1),
multimodeE50(2),
multimode50(3),
multimode625(4),
copper(5),
singlemodeKm(6),
multimodeOM3(7),
multimodeOM3Qsfp(8),
multimodeOM2Qsfp(9),
multimodeOM1Qsfp(10),
multimodeOM4Qsfp(11)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Types of the fiber,
single_mode, multi_modeE50, multi_mode50,multi_mode625,copper,
single_modeKm,multi_modeOM3,multi_modeOM3Qsfp,multi_modeOM2Qsfp,
multi_modeOM1Qsfp,multi_modeOM4Qsfp.
this object belongs to xfp, sfp and qsfp.
"
::= { rosMgmtOpticalTransceiverInfoEntry 6 }
rosMgmtOpticalTransceiverTransmissionDistance OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The max distance which the interface could transmit,
measured in meter.
The object will be shown in unit of Km, and the precision is 0.001.
this object belongs to xfp and sfp.
"
::= { rosMgmtOpticalTransceiverInfoEntry 7 }
rosMgmtOpticalTransceiverAbility OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the ability of optical module digitaldiagnotic
funtion. Currently, the digitaldiagnotic objects of our optical module
inculde 16 parameters.
this object has 32 bits, each bit represents a digital diagnotic parameter.
if the bit value is 0, it means that the optical module does not provide
digital diagnotic funtion for relative parameter.if the bit value is 1,it
means that the optical module provides digital diagnotic funtion for
relative parameter.
this object belongs to xfp and sfp.
The relation between parameters and bits is following:
32...16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1:
The relation between parameters and bits is following:
32...16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1:
| 1bit | 2bit | 3bit | 4bit
| APD Bias voltage | 0(reserve) | TEC Current | Laser temperature
| 5bit | 6bit |7bit | 8bit
| Laser wavelength | +5V Supply voltage | +3.3V Supply voltage | +1.8V Supply voltage
| 9bit | 10bit |11bit | 12bit
| -5.2V Supply voltage | +5V Supply current | 0(None) | 0(None)
| 13bit | 14bit | 15bit | 16bit
| +3.3V Supply current | +1.8V Supply current | -5.2V Supply current | temperature
| 17bit | 18bit | 19bit | 20bit ~ 32bit
| Laser bias current | Rx power |Tx power | 0
But when the optical module is sfp, the 6 bit will represents
the supplyVoltage of sfp.
"
::= { rosMgmtOpticalTransceiverInfoEntry 8 }
rosMgmtOpticalTransceiverDDM OBJECT-TYPE
SYNTAX INTEGER{
support(1),
notsupport(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies if the transceiver supports on digital diagnostic function,
support or not support.To the xfp, the default value of this object is support.
this object belongs to xfp and sfp.
"
::= { rosMgmtOpticalTransceiverInfoEntry 9 }
rosMgmtOpticalTransceiverCalibrationType OBJECT-TYPE
SYNTAX INTEGER{
unknown(1),
internal(2),
external(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the calibration type of the transceiver,
internal, external, unknown.
this object belongs to xfp and sfp.
"
::= { rosMgmtOpticalTransceiverInfoEntry 10 }
rosMgmtOpticalTransceiverRSSI OBJECT-TYPE
SYNTAX INTEGER{
support(1),
notsupport(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the calibration type of the transceiver,
support or not support.
this object belongs to xfp and sfp.
"
::= { rosMgmtOpticalTransceiverInfoEntry 11 }
rosMgmtOpticalTransceiverVendorRev OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" the version number of the transceiver.
this object belongs to xfp and sfp.
"
::= { rosMgmtOpticalTransceiverInfoEntry 12 }
rosMgmtOpticalTransceiverBRMax OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" the min data rate of the transceiver,mesured in Mbps .
this object belongs to xfp and sfp.
The object will be shown in unit of Gbps, and the precision is 0.1.
"
::= { rosMgmtOpticalTransceiverInfoEntry 13 }
rosMgmtOpticalTransceiverBRMin OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" the min data rate of the transceiver,mesured in Mbps.
this object belongs to xfp and sfp.To the sfp,
the min data rate value is equal to the max data rate value.
The object will be shown in unit of Gbps, and the precision is 0.1.
"
::= { rosMgmtOpticalTransceiverInfoEntry 14 }
rosMgmtOpticalTransceiverWavelengthContrl OBJECT-TYPE
SYNTAX INTEGER
{
support(1),
notsupport (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"if the transceiver supports on wavelength control
support,notsupport.
this object belongs to xfp.
"
::= { rosMgmtOpticalTransceiverInfoEntry 15 }
rosMgmtOpticalTransceiverWavelength OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Wavelength of the interface, measured in pm(0.001nm).
this object belongs to xfp.
The object will be shown in unit of nm, and the precision is 0.01.
"
::= { rosMgmtOpticalTransceiverInfoEntry 16 }
rosMgmtOpticalTransceiverWaveTolerance OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"the range of laser wavelength from nominal wavelength,mesured in pm(0.001*nm).
this object belongs to xfp.
The object will be shown in unit of nm, and the precision is 0.01.
"
::= { rosMgmtOpticalTransceiverInfoEntry 17 }
rosMgmtOpticalTransceiverCompatibility OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"the compatibility type that the transceiver supports,such as 10GBASE-SR.
this object belongs to xfp.
"
::= { rosMgmtOpticalTransceiverInfoEntry 18 }
rosMgmtOpticalTransceiverPowerDissipation OBJECT-TYPE
SYNTAX INTEGER
{
p1W5(1),
p2W5(2),
p3W5(3),
exceed(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"the max power dissipation of the transceiver,
p1W5,p2W5,p3W5,exceed3W5.
this object belongs to xfp.
"
::= { rosMgmtOpticalTransceiverInfoEntry 19 }
rosMgmtOpticalTransceiverCDR OBJECT-TYPE
SYNTAX INTEGER
{
support(1),
notsupport(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"the optical module supports on CDR fundtion.
support,notsupport.
this object belongs to xfp.
"
::= { rosMgmtOpticalTransceiverInfoEntry 20 }
rosMgmtOpticalTransceiverRefClock OBJECT-TYPE
SYNTAX INTEGER
{
required(1),
notrequired (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" if the transceiver requires outside reference clock
required,notrequired.
this object belongs to xfp.
"
::= { rosMgmtOpticalTransceiverInfoEntry 21 }
rosMgmtOpticalTransceiverTransmitterType OBJECT-TYPE
SYNTAX INTEGER
{
vcsel850nm(1),
vcsel1310nm(2),
vcsel1550nm(3),
fp1310nm(4),
dfb1310nm(5),
dfb1550nm(6),
eml1310nm(7),
eml1550nm(8),
copperothers(9)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The transmitter type of the transceiver,such as 850 nm VCSEL.
this object belongs to xfp.
"
::= { rosMgmtOpticalTransceiverInfoEntry 22 }
rosMgmtOpticalTransceiverCooled OBJECT-TYPE
SYNTAX INTEGER
{
cooled(1),
uncooled (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The transmitter cooled type of the transceiver
cooled,uncooled.
this object belongs to xfp.
"
::= { rosMgmtOpticalTransceiverInfoEntry 24 }
rosMgmtOpticalTransceiverTunalbe OBJECT-TYPE
SYNTAX INTEGER
{
tunable (1),
untunable (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The transmitter tunable type of the transceiver
tunable,untunable.
this object belongs to xfp.
"
::= { rosMgmtOpticalTransceiverInfoEntry 25 }
rosMgmtOpticalTransceiverDetectorType OBJECT-TYPE
SYNTAX INTEGER
{
pin(1),
apd(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The detector type of the transceiver
pin, apd.
this object belongs to xfp.
"
::= { rosMgmtOpticalTransceiverInfoEntry 26 }
rosMgmtOpticalTransceiverLineLoopBack OBJECT-TYPE
SYNTAX INTEGER
{
support(1),
notsupport(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The transceiver support status of sideline loop-back control
support,notsupport.
this object belongs to xfp.
"
::= { rosMgmtOpticalTransceiverInfoEntry 27 }
rosMgmtOpticalTransceiverXFILoopBack OBJECT-TYPE
SYNTAX INTEGER
{
support(1),
notsupport(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The transceiver support status of XFI loop-back control
support,notsupport.
this object belongs to xfp.
"
::= { rosMgmtOpticalTransceiverInfoEntry 28 }
rosMgmtOpticalTransceiverVps OBJECT-TYPE
SYNTAX INTEGER
{
support(1),
notsupport(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies if the optical module supports on VPS
support,notsupport.
this object belongs to xfp.
"
::= { rosMgmtOpticalTransceiverInfoEntry 29 }
rosMgmtOpticalTransceiverTxDis OBJECT-TYPE
SYNTAX INTEGER
{
support(1),
notsupport(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The transceiver support status of software control the transmitter status
support,notsupport.
this object belongs to xfp.
"
::= { rosMgmtOpticalTransceiverInfoEntry 30 }
rosMgmtOpticalTransceiverStandby OBJECT-TYPE
SYNTAX INTEGER
{
support(1),
notsupport(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The transceiver support status of software control the standby mode.
support,notsupport.
this object belongs to xfp.
"
::= { rosMgmtOpticalTransceiverInfoEntry 31 }
rosMgmtOpticalTransceiverInVpsLowPower OBJECT-TYPE
SYNTAX INTEGER
{
support(1),
notsupport(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VPS in low power support status of the transceiver
support,notsupport.
this object belongs to xfp.
"
::= { rosMgmtOpticalTransceiverInfoEntry 32 }
rosMgmtOpticalTransceiverOutVpsLowPower OBJECT-TYPE
SYNTAX INTEGER
{
support(1),
notsupport(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VPS out low power support status of the transceiver
support,notsupport.
this object belongs to xfp.
"
::= { rosMgmtOpticalTransceiverInfoEntry 33 }
rosMgmtOpticalTransceiverFEC OBJECT-TYPE
SYNTAX INTEGER
{
support(1),
notsupport(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The FEC support status of transceiver
support,notsupport.
this object belongs to xfp.
"
::= { rosMgmtOpticalTransceiverInfoEntry 34 }
rosMgmtOpticalTransceiverCMU OBJECT-TYPE
SYNTAX INTEGER
{
support(1),
notsupport(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The CMU support status of transceiver
support,notsupport.
this object belongs to xfp.
"
::= { rosMgmtOpticalTransceiverInfoEntry 35 }
rosMgmtOpticalTransceiverBR OBJECT-TYPE
SYNTAX INTEGER
{
unknown(0),
bitrate125Mbps(1),
bitrate155Mbps (2),
bitrate622Mbps(6),
bitrate1250Mbps(12),
bitrate1DOT25Gbps(13),
bitrate2DOT5Gbps(19),
bitrate10GbpsOr100Gbps1(103),
bitrate100Gbps2(114),
bitrate25Gbps(255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the Nominal bitrate of the transceiver,
125Mbps, 155Mbps, 622Mbps, 1.25Gbps, 2.5Gbps, 10Gbps, 100Gbps, 25Gbps.
this object belongs to xfp and sfp and qsfp and qsfp28.
"
::= { rosMgmtOpticalTransceiverInfoEntry 36 }
-- rosMgmtOpticalDDMTable
rosMgmtOpticalTransceiverDDMTable OBJECT-TYPE
SYNTAX SEQUENCE OF RosMgmtOpticalTransceiverDDMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table provides objects to monitor optical
parameters in a network element. "
::={ rosMgmtOpticalTransceiverDDMGroup 1 }
rosMgmtOpticalTransceiverDDMEntry OBJECT-TYPE
SYNTAX RosMgmtOpticalTransceiverDDMEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the rosMgmtOpticalTransceiverMonTable provides objects to
monitor an optical parameter at an optical interface.
"
INDEX { ifIndex,
rosMgmtOpticalTransceiverParameterType
}
::={ rosMgmtOpticalTransceiverDDMTable 1 }
RosMgmtOpticalTransceiverDDMEntry ::= SEQUENCE {
rosMgmtOpticalTransceiverParameterType OpticalParameterType,
-- rosMgmtOpticalTransceiverOPType INTEGER,
rosMgmtOpticalTransceiverParameterValue OpticalParameterValue,
rosMgmtOpticalTransceiverParamHighAlarmThresh OpticalParameterValue,
rosMgmtOpticalTransceiverParamHighWarningThresh OpticalParameterValue,
rosMgmtOpticalTransceiverParamLowAlarmThresh OpticalParameterValue,
rosMgmtOpticalTransceiverParamLowWarningThresh OpticalParameterValue,
rosMgmtOpticalTransceiverParamAlarmStatus INTEGER,
rosMgmtOpticalTransceiverParamAlarmLastValue OpticalParameterValue,
rosMgmtOpticalTransceiverParamAlarmLastChange TimeTicks,
rosMgmtOpticalTransceiverDDM15MinValidIntervals Unsigned32,
rosMgmtOpticalTransceiverDDM24HrValidIntervals Unsigned32,
rosMgmtOpticalTransceiverDDMValidStatus INTEGER,
rosMgmtOpticalTransceiverQsfpParameterValue OCTET STRING,
rosMgmtOpticalTransceiverQsfpParamHighAlarmThresh OCTET STRING,
rosMgmtOpticalTransceiverQsfpParamHighWarningThresh OCTET STRING,
rosMgmtOpticalTransceiverQsfpParamLowAlarmThresh OCTET STRING,
rosMgmtOpticalTransceiverQsfpParamLowWarningThresh OCTET STRING,
rosMgmtOpticalTransceiverQsfpParamAlarmStatus OCTET STRING,
rosMgmtOpticalTransceiverQsfpParamAlarmLastValue OCTET STRING,
rosMgmtOpticalTransceiverQsfpParamAlarmLastChange OCTET STRING,
rosMgmtOpticalTransceiverQsfpDDM15MinValidIntervals OCTET STRING,
rosMgmtOpticalTransceiverQsfpDDM24HrValidIntervals OCTET STRING,
rosMgmtOpticalTransceiverQsfpDDMValidStatus OCTET STRING
}
rosMgmtOpticalTransceiverParameterType OBJECT-TYPE
SYNTAX OpticalParameterType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object specifies the optical parameter that is being
monitored in this entry.
This object belongs to xfp/sfp.
"
::={ rosMgmtOpticalTransceiverDDMEntry 1 }
--rosMgmtOpticalTransceiverOPType OBJECT-TYPE
-- SYNTAX INTEGER
-- {
-- others(1),
-- sfp(2),
-- xfp(3),
-- sfpj(4),
-- qsfp(5)
-- }
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "This object specifies the optical type "
-- ::={ rosMgmtOpticalTransceiverDDMEntry 2 }
rosMgmtOpticalTransceiverParameterValue OBJECT-TYPE
SYNTAX OpticalParameterValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object gives the value measured for the particular
optical parameter specified by the rosMgmtOpticalMonParameterType
object.
This object belongs to xfp/sfp.
"
::={ rosMgmtOpticalTransceiverDDMEntry 2 }
rosMgmtOpticalTransceiverParamHighAlarmThresh OBJECT-TYPE
SYNTAX OpticalParameterValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object gives the high alarm threshold on the
optical parameter being monitored.
An alarm condition will be raised if the value given by
rosMgmtOpticalParameterValue goes from below the value of
this object to above the value of this object, or if
the initial value of rosMgmtOpticalParameterValue exceeds the value
of this object. This alarm will be indicated in the
rosMgmtOpticalParamAlarmStatus object.
This object belongs to xfp/sfp.
"
::={ rosMgmtOpticalTransceiverDDMEntry 3 }
rosMgmtOpticalTransceiverParamHighWarningThresh OBJECT-TYPE
SYNTAX OpticalParameterValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to set a high warning threshold on
the optical parameter being monitored.
A threshold crossing condition will be indicated if the value
given by rosMgmtOpticalParameterValue goes from below the value
of this object to above the value of this
object, or if the initial value of rosMgmtOpticalParameterValue
exceeds the value of this object. This alarm will be indicated in the
rosMgmtOpticalParamAlarmStatus object.
This object belongs to xfp/sfp.
"
::={ rosMgmtOpticalTransceiverDDMEntry 4 }
rosMgmtOpticalTransceiverParamLowAlarmThresh OBJECT-TYPE
SYNTAX OpticalParameterValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to set a low alarm threshold on the
optical parameter being monitored.
An alarm condition will be raised if the value given by
rosMgmtOpticalParameterValue goes from above the value of
this object to below the value of this object, or if
the initial value of rosMgmtOpticalParameterValue is lower than the
value of this object. This alarm
will be indicated in the rosMgmtOpticalParamAlarmStatus object ..
This object belongs to xfp/sfp.
"
::={ rosMgmtOpticalTransceiverDDMEntry 5 }
rosMgmtOpticalTransceiverParamLowWarningThresh OBJECT-TYPE
SYNTAX OpticalParameterValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to set a low warning threshold on
the optical parameter being monitored.
A threshold crossing condition will be indicated if the value
given by rosMgmtOpticalParameterValue goes from above the value
of this object to below the value of this
object, or if the initial value of rosMgmtOpticalParameterValue
object is lower than the value of this object. For
network elements in the status
indications, this threshold violation will be indicated in the
rosMgmtOpticalParamAlarmStatus object .
This object belongs to xfp/sfp.
"
::={ rosMgmtOpticalTransceiverDDMEntry 6 }
rosMgmtOpticalTransceiverParamAlarmStatus OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
highalarm(2),
highwarning(3),
lowalarm(4),
lowwarning(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to indicate the current status of
the thresholds for the monitored optical parameter
on the interface.
If a threshold is currently being exceeded on the
interface, the object will be set. Otherwise,
the object will be set to 1.
This object belongs to xfp/sfp.
"
::={ rosMgmtOpticalTransceiverDDMEntry 7 }
rosMgmtOpticalTransceiverParamAlarmLastValue OBJECT-TYPE
SYNTAX OpticalParameterValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the optical parameter value at the last time
a threshold related to a particular optical parameter was
exceeded on the interface.
If no threshold value is currently being
exceeded, then the value '-1000000' is returned.
This object belongs to xfp/sfp.
"
::={ rosMgmtOpticalTransceiverDDMEntry 8 }
rosMgmtOpticalTransceiverParamAlarmLastChange OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the value of sysUpTime at the last time
a threshold related to a particular optical parameter was
exceeded on the interface.
This object belongs to xfp/sfp.
"
::={ rosMgmtOpticalTransceiverDDMEntry 9 }
rosMgmtOpticalTransceiverDDM15MinValidIntervals OBJECT-TYPE
SYNTAX Unsigned32 (0..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object gives the number of previous 15 minute
intervals for which valid performance monitoring data
has been stored on the interface.
The value of this object will be n (where n is the maximum
number of 15 minute intervals supported at this interface),
unless the measurement was (re-)started within the last
(nx15) minutes, in which case the value will be the
number of previous 15 minute intervals for which the agent
has some data.
This object belongs to xfp/sfp.
"
::={ rosMgmtOpticalTransceiverDDMEntry 10 }
rosMgmtOpticalTransceiverDDM24HrValidIntervals OBJECT-TYPE
SYNTAX Unsigned32 (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object gives the number of previous 24 hour intervals
for which valid performance monitoring data has been stored
on the interface. The max value of this object is 7, it
means that the user can look up 7days history information.
This object belongs to xfp/sfp.
"
::={ rosMgmtOpticalTransceiverDDMEntry 11 }
rosMgmtOpticalTransceiverDDMValidStatus OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
invalid(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the parameter row is valid or invalid.
The object value is 'valide' when the module is present and
supporting digitaldiagnotic. The object value is 'invalid'
when the module is absent, or when the module is present and
not supporting digitaldiagnotic.
This object belongs to xfp/sfp.
"
::={ rosMgmtOpticalTransceiverDDMEntry 12 }
rosMgmtOpticalTransceiverQsfpParameterValue OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object gives the value measured for the particular
optical parameter specified by the rosMgmtOpticalMonParameterType
object.
This object belongs to Qsfp.
"
::={ rosMgmtOpticalTransceiverDDMEntry 13 }
rosMgmtOpticalTransceiverQsfpParamHighAlarmThresh OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object gives the high alarm threshold on the
optical parameter being monitored.
An alarm condition will be raised if the value given by
rosMgmtOpticalParameterValue goes from below the value of
this object to above the value of this object, or if
the initial value of rosMgmtOpticalParameterValue exceeds the value
of this object. This alarm will be indicated in the
rosMgmtOpticalParamAlarmStatus object.
This object belongs to Qsfp.
"
::={ rosMgmtOpticalTransceiverDDMEntry 14 }
rosMgmtOpticalTransceiverQsfpParamHighWarningThresh OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to set a high warning threshold on
the optical parameter being monitored.
A threshold crossing condition will be indicated if the value
given by rosMgmtOpticalParameterValue goes from below the value
of this object to above the value of this
object, or if the initial value of rosMgmtOpticalParameterValue
exceeds the value of this object. This alarm will be indicated in the
rosMgmtOpticalParamAlarmStatus object.
This object belongs to Qsfp.
"
::={ rosMgmtOpticalTransceiverDDMEntry 15 }
rosMgmtOpticalTransceiverQsfpParamLowAlarmThresh OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to set a low alarm threshold on the
optical parameter being monitored.
An alarm condition will be raised if the value given by
rosMgmtOpticalParameterValue goes from above the value of
this object to below the value of this object, or if
the initial value of rosMgmtOpticalParameterValue is lower than the
value of this object. This alarm
will be indicated in the rosMgmtOpticalParamAlarmStatus object ..
This object belongs to Qsfp.
"
::={ rosMgmtOpticalTransceiverDDMEntry 16 }
rosMgmtOpticalTransceiverQsfpParamLowWarningThresh OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to set a low warning threshold on
the optical parameter being monitored.
A threshold crossing condition will be indicated if the value
given by rosMgmtOpticalParameterValue goes from above the value
of this object to below the value of this
object, or if the initial value of rosMgmtOpticalParameterValue
object is lower than the value of this object. For
network elements in the status
indications, this threshold violation will be indicated in the
rosMgmtOpticalParamAlarmStatus object .
This object belongs to Qsfp.
"
::={ rosMgmtOpticalTransceiverDDMEntry 17 }
rosMgmtOpticalTransceiverQsfpParamAlarmStatus OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is used to indicate the current status of
the thresholds for the monitored optical parameter
on the interface.
If a threshold is currently being exceeded on the
interface, the object will be set. Otherwise,
the object will be set to 1.
This object belongs to Qsfp.
"
::={ rosMgmtOpticalTransceiverDDMEntry 18 }
rosMgmtOpticalTransceiverQsfpParamAlarmLastValue OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the optical parameter value at the last time
a threshold related to a particular optical parameter was
exceeded on the interface.
If no threshold value is currently being
exceeded, then the value '-1000000' is returned.
This object belongs to Qsfp.
"
::={ rosMgmtOpticalTransceiverDDMEntry 19 }
rosMgmtOpticalTransceiverQsfpParamAlarmLastChange OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the value of sysUpTime at the last time
a threshold related to a particular optical parameter was
exceeded on the interface.
This object belongs to Qsfp.
"
::={ rosMgmtOpticalTransceiverDDMEntry 20 }
rosMgmtOpticalTransceiverQsfpDDM15MinValidIntervals OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object gives the number of previous 15 minute
intervals for which valid performance monitoring data
has been stored on the interface.
The value of this object will be n (where n is the maximum
number of 15 minute intervals supported at this interface),
unless the measurement was (re-)started within the last
(nx15) minutes, in which case the value will be the
number of previous 15 minute intervals for which the agent
has some data.
This object belongs to Qsfp.
"
::={ rosMgmtOpticalTransceiverDDMEntry 21 }
rosMgmtOpticalTransceiverQsfpDDM24HrValidIntervals OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object gives the number of previous 24 hour intervals
for which valid performance monitoring data has been stored
on the interface. The max value of this object is 7, it
means that the user can look up 7days history information.
This object belongs to Qsfp.
"
::={ rosMgmtOpticalTransceiverDDMEntry 22 }
rosMgmtOpticalTransceiverQsfpDDMValidStatus OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the parameter row is valid or invalid.
The object value is 'valide' when the module is present and
supporting digitaldiagnotic. The object value is 'invalid'
when the module is absent, or when the module is present and
not supporting digitaldiagnotic.
This object belongs to Qsfp.
"
::={ rosMgmtOpticalTransceiverDDMEntry 23 }
-- rosMgmtOpticalTransceiverPMCurrent Table
rosMgmtOpticalTransceiverPMCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF RosMgmtOpticalTransceiverPMCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains performance monitoring data for the
various optical parameters, collected over the current 15
minute or the current 24 hour interval."
::={ rosMgmtOpticalTransceiverPMGroup 1 }
rosMgmtOpticalTransceiverPMCurrentEntry OBJECT-TYPE
SYNTAX RosMgmtOpticalTransceiverPMCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the rosMgmtOpticalTransceiverPMCurrentTable. It contains
performance monitoring data for a monitored optical
parameter at an interface, collected over the current 15
minute or the current 24 hour interval.
"
INDEX { ifIndex,
rosMgmtOpticalTransceiverPMCurrentPeriod,
rosMgmtOpticalTransceiverPMCurrentParamType }
::={ rosMgmtOpticalTransceiverPMCurrentTable 1 }
RosMgmtOpticalTransceiverPMCurrentEntry ::= SEQUENCE {
rosMgmtOpticalTransceiverPMCurrentPeriod OpticalPMPeriod,
rosMgmtOpticalTransceiverPMCurrentParamType OpticalParameterType,
-- rosMgmtOpticalTransceiverPMType INTEGER,
rosMgmtOpticalTransceiverPMCurrentMaxParam OpticalParameterValue,
rosMgmtOpticalTransceiverPMCurrentMinParam OpticalParameterValue,
rosMgmtOpticalTransceiverPMCurrentMeanParam OpticalParameterValue,
rosMgmtOpticalTransceiverQsfpPMCurrentMaxParam OCTET STRING,
rosMgmtOpticalTransceiverQsfpPMCurrentMinParam OCTET STRING,
rosMgmtOpticalTransceiverQsfpPMCurrentMeanParam OCTET STRING
}
rosMgmtOpticalTransceiverPMCurrentPeriod OBJECT-TYPE
SYNTAX OpticalPMPeriod
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates whether the optical parameter values
given in this entry are collected over the current 15 minute or
the current 24 hour interval.
This object belongs to xfp/sfp.
"
::={ rosMgmtOpticalTransceiverPMCurrentEntry 1 }
rosMgmtOpticalTransceiverPMCurrentParamType OBJECT-TYPE
SYNTAX OpticalParameterType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object specifies the optical parameter that is being
monitored, in this entry.
This object belongs to xfp/sfp.
"
::={ rosMgmtOpticalTransceiverPMCurrentEntry 2 }
-- rosMgmtOpticalTransceiverPMType OBJECT-TYPE
-- SYNTAX INTEGER
-- {
-- others(1),
-- sfp(2),
-- xfp(3),
-- sfpj(4),
-- qsfp(5)
-- }
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "This object specifies the optical type "
-- ::={ rosMgmtOpticalTransceiverPMCurrentEntry 3 }
rosMgmtOpticalTransceiverPMCurrentMaxParam OBJECT-TYPE
SYNTAX OpticalParameterValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object gives the maximum value measured for the monitored
optical parameter, in the current 15 minute or the current
24 hour interval.
This object belongs to xfp/sfp.
"
::={ rosMgmtOpticalTransceiverPMCurrentEntry 3 }
rosMgmtOpticalTransceiverPMCurrentMinParam OBJECT-TYPE
SYNTAX OpticalParameterValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object gives the minimum value measured for the monitored
optical parameter, in the current 15 minute or the current
24 hour interval.
This object belongs to xfp/sfp.
"
::={ rosMgmtOpticalTransceiverPMCurrentEntry 4 }
rosMgmtOpticalTransceiverPMCurrentMeanParam OBJECT-TYPE
SYNTAX OpticalParameterValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object gives the average value of the monitored
optical parameter, in the current 15 minute or the current
24 hour interval.
This object belongs to xfp/sfp.
"
::={ rosMgmtOpticalTransceiverPMCurrentEntry 5 }
rosMgmtOpticalTransceiverQsfpPMCurrentMaxParam OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object gives the maximum value measured for the monitored
optical parameter, in the current 15 minute or the current
24 hour interval.
This object belongs to Qsfp
"
::={ rosMgmtOpticalTransceiverPMCurrentEntry 6 }
rosMgmtOpticalTransceiverQsfpPMCurrentMinParam OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object gives the minimum value measured for the monitored
optical parameter, in the current 15 minute or the current
24 hour interval.
This object belongs to Qsfp.
"
::={ rosMgmtOpticalTransceiverPMCurrentEntry 7 }
rosMgmtOpticalTransceiverQsfpPMCurrentMeanParam OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object gives the average value of the monitored
optical parameter, in the current 15 minute or the current
24 hour interval.
This object belongs to Qsfp.
"
::={ rosMgmtOpticalTransceiverPMCurrentEntry 8 }
-- rosMgmtOpticalTransceiverPMInterval Table
rosMgmtOpticalTransceiverPMIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF RosMgmtOpticalTransceiverPMIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table stores performance monitoring data for the
various optical parameters, collected over previous
intervals.
This table can have entries for one complete 24 hour
interval and up to 96 complete 15 minute
intervals. A system is required to store at least
4 completed 15 minute intervals. The number of valid
15 minute intervals in this table is indicated by the
rosMgmtOpticalTransceiverDDM15MinValidIntervals object
and the number of valid 24 hour intervals is indicated by the
rosMgmtOpticalTransceiverDDM24HrValidIntervals object.
when the optical module is removed from the device, the relative
history records will be cleaned.
"
::={ rosMgmtOpticalTransceiverPMGroup 2 }
rosMgmtOpticalTransceiverPMIntervalEntry OBJECT-TYPE
SYNTAX RosMgmtOpticalTransceiverPMIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the rosMgmtOpticalTransceiverPMIntervalTable. It contains
performance monitoring data for an optical parameter,
collected over a previous interval.
"
INDEX { ifIndex,
rosMgmtOpticalTransceiverPMIntervalPeriod,
rosMgmtOpticalTransceiverPMIntervalNumber,
rosMgmtOpticalTransceiverPMIntervalParamType }
::={ rosMgmtOpticalTransceiverPMIntervalTable 1 }
RosMgmtOpticalTransceiverPMIntervalEntry ::= SEQUENCE {
rosMgmtOpticalTransceiverPMIntervalPeriod OpticalPMPeriod,
rosMgmtOpticalTransceiverPMIntervalNumber Integer32,
rosMgmtOpticalTransceiverPMIntervalParamType OpticalParameterType,
-- rosMgmtOpticalTransceiverPMIntervalType INTEGER,
rosMgmtOpticalTransceiverPMIntervalMaxParam OpticalParameterValue,
rosMgmtOpticalTransceiverPMIntervalMinParam OpticalParameterValue,
rosMgmtOpticalTransceiverPMIntervalMeanParam OpticalParameterValue,
rosMgmtOpticalTransceiverQsfpPMIntervalMaxParam OCTET STRING,
rosMgmtOpticalTransceiverQsfpPMIntervalMinParam OCTET STRING,
rosMgmtOpticalTransceiverQsfpPMIntervalMeanParam OCTET STRING
}
rosMgmtOpticalTransceiverPMIntervalPeriod OBJECT-TYPE
SYNTAX OpticalPMPeriod
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates whether the optical parameter values,
given in this entry, are collected over a period of 15 minutes
or 24 hours.
This object belongs to xfp/sfp.
"
::={ rosMgmtOpticalTransceiverPMIntervalEntry 1 }
rosMgmtOpticalTransceiverPMIntervalNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the
interval for which the set of optical parameter values is
available. The interval identified by 1 is the most recently
completed 15 minute or 24 hour interval, and the interval
identified by N is the interval immediately preceding the one
identified by N-1.
This object belongs to xfp/sfp.
"
::={ rosMgmtOpticalTransceiverPMIntervalEntry 2 }
rosMgmtOpticalTransceiverPMIntervalParamType OBJECT-TYPE
SYNTAX OpticalParameterType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object specifies the optical parameter that is being
monitored, in this entry.
This object belongs to xfp/sfp.
"
::={ rosMgmtOpticalTransceiverPMIntervalEntry 3 }
--rosMgmtOpticalTransceiverPMIntervalType OBJECT-TYPE
-- SYNTAX INTEGER
-- {
-- others(1),
-- sfp(2),
-- xfp(3),
-- sfpj(4),
-- qsfp(5)
-- }
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "This object specifies the optical type "
-- ::={ rosMgmtOpticalTransceiverPMIntervalEntry 4 }
rosMgmtOpticalTransceiverPMIntervalMaxParam OBJECT-TYPE
SYNTAX OpticalParameterValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object gives the maximum value measured for the optical
parameter, in a particular 15 minute or 24 hour interval.
This object belongs to xfp/sfp.
"
::={ rosMgmtOpticalTransceiverPMIntervalEntry 4 }
rosMgmtOpticalTransceiverPMIntervalMinParam OBJECT-TYPE
SYNTAX OpticalParameterValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object gives the minimum value measured for the optical
parameter, in a particular 15 minute or 24 hour interval.
This object belongs to xfp/sfp.
"
::={ rosMgmtOpticalTransceiverPMIntervalEntry 5 }
rosMgmtOpticalTransceiverPMIntervalMeanParam OBJECT-TYPE
SYNTAX OpticalParameterValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object gives the average value of the measured optical
parameter, in a particular 15 minute or 24 hour interval.
This object belongs to xfp/sfp.
"
::={ rosMgmtOpticalTransceiverPMIntervalEntry 6 }
rosMgmtOpticalTransceiverQsfpPMIntervalMaxParam OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object gives the maximum value measured for the optical
parameter, in a particular 15 minute or 24 hour interval.
This object belongs to Qsfp.
"
::={ rosMgmtOpticalTransceiverPMIntervalEntry 7 }
rosMgmtOpticalTransceiverQsfpPMIntervalMinParam OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object gives the minimum value measured for the optical
parameter, in a particular 15 minute or 24 hour interval.
This object belongs to Qsfp.
"
::={ rosMgmtOpticalTransceiverPMIntervalEntry 8 }
rosMgmtOpticalTransceiverQsfpPMIntervalMeanParam OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object gives the average value of the measured optical
parameter, in a particular 15 minute or 24 hour interval.
This object belongs to Qsfp.
"
::={ rosMgmtOpticalTransceiverPMIntervalEntry 9 }
-- rosMgmtOpticalTransceiverCurrentStatus Table
rosMgmtOpticalTransceiverCurrentStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF RosMgmtOpticalTransceiverCurrentStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table stores the hard ware information and the information
set by user of the transceiver.
This object belongs to xfp/sfp.
"
::={ rosMgmtOpticalTransceiverStatusGroup 1 }
rosMgmtOpticalTransceiverCurrentStatusEntry OBJECT-TYPE
SYNTAX RosMgmtOpticalTransceiverCurrentStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the rosMgmtOpticalTransceiverCurrentStatusTable. It contains
performance monitoring data for an optical parameter,
collected over a previous interval.
This object belongs to xfp/sfp.
"
INDEX { ifIndex }
::={ rosMgmtOpticalTransceiverCurrentStatusTable 1 }
RosMgmtOpticalTransceiverCurrentStatusEntry ::= SEQUENCE {
rosMgmtOpticalTransceiverHwInfoAbsStatus INTEGER,
rosMgmtOpticalTransceiverHwInfoNRStatus INTEGER,
rosMgmtOpticalTransceiverHwInfoRxLosStatus INTEGER,
rosMgmtOpticalTransceiverHwInfoStandby INTEGER,
rosMgmtOpticalTransceiverHwInfoLaser INTEGER,
rosMgmtOpticalTransceiverWaveLengthError Integer32,
rosMgmtOpticalTransceiverUserWaveLength Integer32,
rosMgmtOpticalTransceiverUserDataRate Integer32,
rosMgmtOpticalTransceiverUserLineLoopBack INTEGER,
rosMgmtOpticalTransceiverUserXFILoopBack INTEGER,
rosMgmtOpticalTransceiverPortNotifyEnable EnableVar,
rosMgmtOpticalTransceiverPortDDMEnable EnableVar,
rosMgmtOpticalTransceiverPortCheckPwdEnable EnableVar,
rosMgmtOpticalTransceiverTxFaultCount Integer32,
rosMgmtOpticalTransceiverTxFaultCountClear TruthValue,
rosMgmtOpticalTransceiverSpecificationCheckStatus INTEGER,
rosMgmtOpticalTransceiverTxFaultStatus INTEGER,
rosMgmtOpticalTransceiverPortCRCCheckEnable EnableVar,
rosMgmtOpticalTransceiverBaseCRCCheckStatus INTEGER,
rosMgmtOpticalTransceiverStaticDdmCRCCheckStatus INTEGER,
rosMgmtOpticalTransceiverDynamicDdmCRCCheckStatus INTEGER
}
rosMgmtOpticalTransceiverHwInfoAbsStatus OBJECT-TYPE
SYNTAX INTEGER
{
absent(1),
present(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies if the optical module is absent
present,absent.
This object belongs to xfp and sfp."
::={ rosMgmtOpticalTransceiverCurrentStatusEntry 1 }
rosMgmtOpticalTransceiverHwInfoNRStatus OBJECT-TYPE
SYNTAX INTEGER
{
ready(1),
notready(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies if the optical module is ready for operation.
ready,notready.
This object belongs to xfp.
"
::={ rosMgmtOpticalTransceiverCurrentStatusEntry 2 }
rosMgmtOpticalTransceiverHwInfoRxLosStatus OBJECT-TYPE
SYNTAX INTEGER
{
normal(1),
loss(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies if the optical module operation losses the receiving signal
normal,loss.
This object belongs to xfp.
"
::={ rosMgmtOpticalTransceiverCurrentStatusEntry 3 }
rosMgmtOpticalTransceiverHwInfoStandby OBJECT-TYPE
SYNTAX INTEGER
{
normal(1),
standby(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies if the optical module works under standby mode.
normal,standby.
This object belongs to xfp.
"
::={ rosMgmtOpticalTransceiverCurrentStatusEntry 4 }
rosMgmtOpticalTransceiverHwInfoLaser OBJECT-TYPE
SYNTAX INTEGER
{
on(1),
off(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies if the optical module laser is turned on
on,off.
This object belongs to xfp.
"
::={ rosMgmtOpticalTransceiverCurrentStatusEntry 5 }
rosMgmtOpticalTransceiverWaveLengthError OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies error between the actual wavelength
and the wavelength set by the user,measured in pm.
This object belongs to xfp.
The object will be shown in unit of nm, and the precision is 0.001.
"
::={ rosMgmtOpticalTransceiverCurrentStatusEntry 6 }
rosMgmtOpticalTransceiverUserWaveLength OBJECT-TYPE
SYNTAX Integer32(0..3276800)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the wavelength value of the optical module set by user,measured in pm.
This object belongs to xfp.
The object will be shown in unit of nm, and the precision is 0.01.
"
::={ rosMgmtOpticalTransceiverCurrentStatusEntry 7 }
rosMgmtOpticalTransceiverUserDataRate OBJECT-TYPE
SYNTAX Integer32(9500..12500)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the data rate of the optical module set by user,measured in Mbps.
This object belongs to xfp.
The object will be shown in unit of Gbps, and the precision is 0.1.
"
::={ rosMgmtOpticalTransceiverCurrentStatusEntry 8 }
rosMgmtOpticalTransceiverUserLineLoopBack OBJECT-TYPE
SYNTAX INTEGER
{
normal(1),
lineLoopback(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies if the sideline loop-back is tuned on ,
user can change the loop back mode through the object.
normal,lineLoopback.
This object belongs to xfp.
"
::={ rosMgmtOpticalTransceiverCurrentStatusEntry 9 }
rosMgmtOpticalTransceiverUserXFILoopBack OBJECT-TYPE
SYNTAX INTEGER
{
normal(1),
xfiLoopback(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies if the XFI loop-back is tuned on
user can change the loop back mode through the object.
normal,xfiLoopback.
This object belongs to xfp.
"
::={ rosMgmtOpticalTransceiverCurrentStatusEntry 10 }
rosMgmtOpticalTransceiverPortNotifyEnable OBJECT-TYPE
SYNTAX EnableVar
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the generation of a port notifications,
enable or disable.
This object belongs to xfp and sfp.
"
DEFVAL { enable}
::={ rosMgmtOpticalTransceiverCurrentStatusEntry 11 }
rosMgmtOpticalTransceiverPortDDMEnable OBJECT-TYPE
SYNTAX EnableVar
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the status of digitaldiagnotic on a port,
enable or disable.
This object belongs to xfp and sfp.
"
DEFVAL { enable}
::={ rosMgmtOpticalTransceiverCurrentStatusEntry 12 }
rosMgmtOpticalTransceiverPortCheckPwdEnable OBJECT-TYPE
SYNTAX EnableVar
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the status of password checking on a port,
enable or disable.
This object belongs to xfp.
"
DEFVAL { enable}
::={ rosMgmtOpticalTransceiverCurrentStatusEntry 13 }
rosMgmtOpticalTransceiverTxFaultCount OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the number of tx-fault signals."
::={ rosMgmtOpticalTransceiverCurrentStatusEntry 14 }
rosMgmtOpticalTransceiverTxFaultCountClear OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies clear the statistcs of tx-fault signals."
::={ rosMgmtOpticalTransceiverCurrentStatusEntry 15 }
rosMgmtOpticalTransceiverSpecificationCheckStatus OBJECT-TYPE
SYNTAX INTEGER{none(0),accord(1),notaccord(2)}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the check status, accord(0)specifies
the optical module accord with industrial. not-accord(2)
specifies the optical module not accord with industrial."
::={ rosMgmtOpticalTransceiverCurrentStatusEntry 16 }
rosMgmtOpticalTransceiverTxFaultStatus OBJECT-TYPE
SYNTAX INTEGER{normal(1),txfault(2)}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the tx-fault status."
::={ rosMgmtOpticalTransceiverCurrentStatusEntry 17 }
rosMgmtOpticalTransceiverPortCRCCheckEnable OBJECT-TYPE
SYNTAX EnableVar
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the status of CRC checking on a port, enable or disable.
This object belongs to sfp and xfp"
::={ rosMgmtOpticalTransceiverCurrentStatusEntry 18 }
rosMgmtOpticalTransceiverBaseCRCCheckStatus OBJECT-TYPE
SYNTAX INTEGER
{
none(0),
pass(1),
notpass(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the result of base information crc checking."
::={ rosMgmtOpticalTransceiverCurrentStatusEntry 19 }
rosMgmtOpticalTransceiverStaticDdmCRCCheckStatus OBJECT-TYPE
SYNTAX INTEGER
{
none(0),
pass(1),
notpass(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the result of static ddm crc checking."
::={ rosMgmtOpticalTransceiverCurrentStatusEntry 20 }
rosMgmtOpticalTransceiverDynamicDdmCRCCheckStatus OBJECT-TYPE
SYNTAX INTEGER
{
none(0),
pass(1),
notpass(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the result of Dynamic ddm crc checking."
::={ rosMgmtOpticalTransceiverCurrentStatusEntry 21 }
END