mirror of
https://github.com/librenms/librenms.git
synced 2024-09-21 10:28:13 +00:00
new device os Raisecom Router OS (ROAP) (#12361)
* new device os Raisecom Router OS (ROAP) tried to add that as existing raisecom os but ended in new os, because they use a new MIB base for Router OS and newer devices. * add sensors
This commit is contained in:
parent
10eb7b2c2a
commit
9126e0f00a
45
includes/definitions/discovery/raisecom-ros.yaml
Normal file
45
includes/definitions/discovery/raisecom-ros.yaml
Normal file
@ -0,0 +1,45 @@
|
||||
mib: ROSMGMT-ALARM-MGMT-MIB:ROSMGMT-COMMON-MANAGEMENT-MIB:ROSMGMT-SYSTEM-MIB:ROSMGMT-VERSION-MIB:ROSMGMT-MEMORY-MIB
|
||||
modules:
|
||||
mempools:
|
||||
data:
|
||||
-
|
||||
total: ROSMGMT-MEMORY-MIB::rosMgmtMemoryTotal
|
||||
free: ROSMGMT-MEMORY-MIB::rosMgmtMemoryAvailable
|
||||
os:
|
||||
hardware: ROSMGMT-VERSION-MIB::rosMgmtProductVersion.0
|
||||
serial: ROSMGMT-VERSION-MIB::rosMgmtSerialNumber.0
|
||||
version: ROSMGMT-VERSION-MIB::rosMgmtRosVersion.0
|
||||
processors:
|
||||
data:
|
||||
-
|
||||
oid: rosMgmtCpuUtilizationTable
|
||||
value: rosMgmtCpuUtilization.oneMin
|
||||
num_oid: '.1.3.6.1.4.1.8886.60.1.1.1.2.1.1.1.3.{{ $index }}'
|
||||
snmp_flags: ['-OeQUsb'] # workaround for one Min index
|
||||
descr: 'Processor'
|
||||
index: 3
|
||||
sensors:
|
||||
state:
|
||||
data:
|
||||
-
|
||||
oid: rosMgmtConfigLoadState
|
||||
value: rosMgmtConfigLoadState
|
||||
num_oid: '.1.3.6.1.4.1.8886.1.2.1.3.{{ $index }}'
|
||||
descr: 'Config {{ $index }} Load State'
|
||||
states:
|
||||
- { graph: 0, value: 1, generic: 1, descr: ready }
|
||||
- { graph: 0, value: 2, generic: 1, descr: running }
|
||||
- { graph: 0, value: 3, generic: 0, descr: successful }
|
||||
- { graph: 0, value: 4, generic: 2, descr: failed }
|
||||
-
|
||||
oid: rosMgmtAlarmMgmtMonitorLevel
|
||||
value: rosMgmtAlarmMgmtMonitorLevel
|
||||
num_oid: '.1.3.6.1.4.1.8886.60.34.1.1.7.{{ $index }}'
|
||||
descr: 'The level of Alarm Monitor'
|
||||
states:
|
||||
- { graph: 0, value: 1, generic: 0, descr: clear }
|
||||
- { graph: 0, value: 2, generic: 0, descr: indeterminate }
|
||||
- { graph: 0, value: 3, generic: 2, descr: critical }
|
||||
- { graph: 0, value: 4, generic: 2, descr: major }
|
||||
- { graph: 0, value: 5, generic: 1, descr: minor }
|
||||
- { graph: 0, value: 6, generic: 1, descr: warning }
|
17
includes/definitions/raisecom-ros.yaml
Normal file
17
includes/definitions/raisecom-ros.yaml
Normal file
@ -0,0 +1,17 @@
|
||||
os: raisecom-ros
|
||||
text: 'Raisecom ROS'
|
||||
type: network
|
||||
bad_snmpEngineTime: true
|
||||
mib_dir: raisecom
|
||||
over:
|
||||
- { graph: device_bits, text: 'Device Traffic' }
|
||||
- { graph: device_processor, text: 'CPU Usage' }
|
||||
- { graph: device_mempool, text: 'Memory Usage' }
|
||||
icon: raisecom
|
||||
discovery:
|
||||
-
|
||||
sysObjectID: .1.3.6.1.4.1.8886
|
||||
snmpget:
|
||||
oid: ROSMGMT-VERSION-MIB::rosMgmtRosVersion.0
|
||||
op: '!='
|
||||
value: false
|
@ -2,6 +2,7 @@ os: raisecom
|
||||
text: 'Raisecom ROAP'
|
||||
type: network
|
||||
bad_snmpEngineTime: true
|
||||
mib_dir: raisecom
|
||||
over:
|
||||
- { graph: device_bits, text: 'Device Traffic' }
|
||||
- { graph: device_processor, text: 'CPU Usage' }
|
||||
@ -9,5 +10,8 @@ over:
|
||||
icon: raisecom
|
||||
discovery:
|
||||
-
|
||||
sysObjectID:
|
||||
- .1.3.6.1.4.1.8886
|
||||
sysObjectID: .1.3.6.1.4.1.8886
|
||||
snmpget:
|
||||
oid: ROSMGMT-VERSION-MIB::rosMgmtRosVersion.0
|
||||
op: '='
|
||||
value: false
|
||||
|
42
includes/discovery/sensors/dbm/raisecom-ros.inc.php
Normal file
42
includes/discovery/sensors/dbm/raisecom-ros.inc.php
Normal file
@ -0,0 +1,42 @@
|
||||
<?php
|
||||
|
||||
echo 'Raisecom';
|
||||
|
||||
$multiplier = 1;
|
||||
$divisor = 1000;
|
||||
foreach ($pre_cache['rosMgmtOpticalTransceiverDDMTable'] as $index => $data) {
|
||||
foreach ($data as $key => $value) {
|
||||
if (($key == 'txPower') && is_numeric($value['rosMgmtOpticalTransceiverParameterValue']) && ($value['rosMgmtOpticalTransceiverDDMValidStatus'] == 1)) {
|
||||
$oid = '.1.3.6.1.4.1.8886.1.18.2.2.1.1.2.' . $index . '.3';
|
||||
$sensor_type = 'rosMgmtOpticalTransceiverTxPower';
|
||||
$port = get_port_by_index_cache($device['device_id'], str_replace('1.', '', $index));
|
||||
$descr = $port['ifDescr'] . ' Transmit Power';
|
||||
$low_limit = $value['rosMgmtOpticalTransceiverParamLowAlarmThresh'] / $divisor;
|
||||
$low_warn_limit = $value['rosMgmtOpticalTransceiverParamLowWarningThresh'] / $divisor;
|
||||
$warn_limit = $value['rosMgmtOpticalTransceiverParamHighWarningThresh'] / $divisor;
|
||||
$high_limit = $value['rosMgmtOpticalTransceiverParamHighAlarmThresh'] / $divisor;
|
||||
$current = $value['rosMgmtOpticalTransceiverParameterValue'] / $divisor;
|
||||
$entPhysicalIndex = $index;
|
||||
$entPhysicalIndex_measured = 'ports';
|
||||
if ($port['ifAdminStatus'] == 'up') {
|
||||
discover_sensor($valid['sensor'], 'dbm', $device, $oid, 'tx-' . $index, $sensor_type, $descr, $divisor, $multiplier, $low_limit, $low_warn_limit, $warn_limit, $high_limit, $current, 'snmp', $entPhysicalIndex, $entPhysicalIndex_measured);
|
||||
}
|
||||
}
|
||||
if (($key == 'rxPower') && is_numeric($value['rosMgmtOpticalTransceiverParameterValue']) && ($value['rosMgmtOpticalTransceiverDDMValidStatus'] != 0)) {
|
||||
$oid = '.1.3.6.1.4.1.8886.1.18.2.2.1.1.2.' . $index . '.4';
|
||||
$sensor_type = 'rosMgmtOpticalTransceiverRxPower';
|
||||
$port = get_port_by_index_cache($device['device_id'], str_replace('1.', '', $index));
|
||||
$descr = $port['ifDescr'] . ' Receive Power';
|
||||
$low_limit = $value['rosMgmtOpticalTransceiverParamLowAlarmThresh'] / $divisor;
|
||||
$low_warn_limit = $value['rosMgmtOpticalTransceiverParamLowWarningThresh'] / $divisor;
|
||||
$warn_limit = $value['rosMgmtOpticalTransceiverParamHighWarningThresh'] / $divisor;
|
||||
$high_limit = $value['rosMgmtOpticalTransceiverParamHighAlarmThresh'] / $divisor;
|
||||
$current = $value['rosMgmtOpticalTransceiverParameterValue'] / $divisor;
|
||||
$entPhysicalIndex = $index;
|
||||
$entPhysicalIndex_measured = 'ports';
|
||||
if ($port['ifAdminStatus'] == 'up') {
|
||||
discover_sensor($valid['sensor'], 'dbm', $device, $oid, 'rx-' . $index, $sensor_type, $descr, $divisor, $multiplier, $low_limit, $low_warn_limit, $warn_limit, $high_limit, $current, 'snmp', $entPhysicalIndex, $entPhysicalIndex_measured);
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
@ -0,0 +1,4 @@
|
||||
<?php
|
||||
|
||||
echo 'rosMgmtOpticalTransceiverDDMTable ';
|
||||
$pre_cache['rosMgmtOpticalTransceiverDDMTable'] = snmpwalk_cache_twopart_oid($device, 'rosMgmtOpticalTransceiverDDMTable', [], 'ROSMGMT-OPTICAL-TRANSCEIVER-MIB', 'raisecom', ['-OeQUs', '-Ih']);
|
24
includes/discovery/sensors/temperature/raisecom-ros.inc.php
Normal file
24
includes/discovery/sensors/temperature/raisecom-ros.inc.php
Normal file
@ -0,0 +1,24 @@
|
||||
<?php
|
||||
|
||||
echo 'Raisecom';
|
||||
|
||||
$multiplier = 1;
|
||||
$divisor = 1000;
|
||||
foreach ($pre_cache['rosMgmtOpticalTransceiverDDMTable'] as $index => $data) {
|
||||
foreach ($data as $key => $value) {
|
||||
if (($key == 'transceiverTemperature') && is_numeric($value['rosMgmtOpticalTransceiverParameterValue']) && ($value['rosMgmtOpticalTransceiverDDMValidStatus'] == 1)) {
|
||||
$oid = '.1.3.6.1.4.1.8886.60.18.1.2.2.1.1.2.' . $index . '.1';
|
||||
$sensor_type = 'rosMgmtOpticalTransceiverTemperature';
|
||||
$port_descr = get_port_by_index_cache($device['device_id'], str_replace('1.', '', $index));
|
||||
$descr = $port_descr['ifDescr'] . ' Transceiver Temperature';
|
||||
$low_limit = $value['rosMgmtOpticalTransceiverParamLowAlarmThresh'] / $divisor;
|
||||
$low_warn_limit = $value['rosMgmtOpticalTransceiverParamLowWarningThresh'] / $divisor;
|
||||
$warn_limit = $value['rosMgmtOpticalTransceiverParamHighWarningThresh'] / $divisor;
|
||||
$high_limit = $value['rosMgmtOpticalTransceiverParamHighAlarmThresh'] / $divisor;
|
||||
$current = $value['rosMgmtOpticalTransceiverParameterValue'] / $divisor;
|
||||
$entPhysicalIndex = $index;
|
||||
$entPhysicalIndex_measured = 'ports';
|
||||
discover_sensor($valid['sensor'], 'temperature', $device, $oid, 'tx-' . $index, $sensor_type, $descr, $divisor, $multiplier, $low_limit, $low_warn_limit, $warn_limit, $high_limit, $current, 'snmp', $entPhysicalIndex, $entPhysicalIndex_measured);
|
||||
}
|
||||
}
|
||||
}
|
137
mibs/IANA-PWE3-MIB
Normal file
137
mibs/IANA-PWE3-MIB
Normal file
@ -0,0 +1,137 @@
|
||||
IANA-PWE3-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY, mib-2
|
||||
FROM SNMPv2-SMI -- [RFC2578]
|
||||
|
||||
TEXTUAL-CONVENTION
|
||||
FROM SNMPv2-TC; -- [RFC2579]
|
||||
|
||||
ianaPwe3MIB MODULE-IDENTITY
|
||||
LAST-UPDATED "200906110000Z" -- 11 June 2009 00:00:00 GMT
|
||||
ORGANIZATION "IANA"
|
||||
CONTACT-INFO
|
||||
"Internet Assigned Numbers Authority
|
||||
Internet Corporation for Assigned Names and Numbers
|
||||
4676 Admiralty Way, Suite 330
|
||||
Marina del Rey, CA 90292-6601
|
||||
|
||||
Phone: +1 310 823 9358
|
||||
EMail: iana@iana.org"
|
||||
DESCRIPTION
|
||||
"This MIB module defines the IANAPwTypeTC and
|
||||
IANAPwPsnTypeTC textual conventions for use in PWE3
|
||||
MIB modules.
|
||||
|
||||
Any additions or changes to the contents of this MIB
|
||||
module require either publication of an RFC, Designated
|
||||
Expert Review as defined in RFC 5226, Guidelines for
|
||||
Writing an IANA Considerations Section in RFCs, and should
|
||||
be based on the procedures defined in [RFC4446]. The
|
||||
Designated Expert will be selected by the IESG Area
|
||||
Director(s) of the internet Area.
|
||||
|
||||
Copyright (c) 2009 IETF Trust and the persons identified as
|
||||
authors of the code. All rights reserved.
|
||||
|
||||
Redistribution and use in source and binary forms, with or
|
||||
without modification, are permitted provided that the
|
||||
|
||||
following conditions are met:
|
||||
|
||||
- Redistributions of source code must retain the above
|
||||
copyright notice, this list of conditions and the
|
||||
following disclaimer.
|
||||
|
||||
- Redistributions in binary form must reproduce the above
|
||||
copyright notice, this list of conditions and the
|
||||
following disclaimer in the documentation and/or other
|
||||
materials provided with the distribution.
|
||||
|
||||
- Neither the name of Internet Society, IETF or IETF Trust,
|
||||
nor the names of specific contributors, may be used to
|
||||
endorse or promote products derived from this software
|
||||
without specific prior written permission.
|
||||
|
||||
THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND
|
||||
CONTRIBUTORS 'AS IS' AND ANY EXPRESS OR IMPLIED WARRANTIES,
|
||||
INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
|
||||
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE
|
||||
DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR
|
||||
CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT,
|
||||
INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES
|
||||
(INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE
|
||||
GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR
|
||||
BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF
|
||||
LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
|
||||
(INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT
|
||||
OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
|
||||
POSSIBILITY OF SUCH DAMAGE. "
|
||||
|
||||
REVISION "200906110000Z" -- 11 June 2009 00:00:00 GMT
|
||||
DESCRIPTION "Original version, published as part of RFC 5601."
|
||||
::= { mib-2 174 }
|
||||
|
||||
IANAPwTypeTC ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates the PW type (i.e., the carried service). "
|
||||
SYNTAX INTEGER {
|
||||
other(0),
|
||||
frameRelayDlciMartiniMode(1),
|
||||
atmAal5SduVcc(2),
|
||||
atmTransparent(3),
|
||||
ethernetTagged(4),
|
||||
ethernet(5),
|
||||
hdlc(6),
|
||||
ppp(7),
|
||||
cem(8), -- Historic type
|
||||
atmCellNto1Vcc(9),
|
||||
atmCellNto1Vpc(10),
|
||||
ipLayer2Transport(11),
|
||||
atmCell1to1Vcc(12),
|
||||
atmCell1to1Vpc(13),
|
||||
atmAal5PduVcc(14),
|
||||
frameRelayPortMode(15),
|
||||
cep(16),
|
||||
e1Satop(17),
|
||||
t1Satop(18),
|
||||
e3Satop(19),
|
||||
t3Satop(20),
|
||||
basicCesPsn(21),
|
||||
basicTdmIp(22),
|
||||
tdmCasCesPsn(23),
|
||||
tdmCasTdmIp(24),
|
||||
frDlci(25),
|
||||
wildcard (32767)
|
||||
}
|
||||
|
||||
IANAPwPsnTypeTC ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Identifies the PSN type that the PW will use over the
|
||||
network."
|
||||
SYNTAX INTEGER {
|
||||
mpls (1),
|
||||
l2tp (2),
|
||||
udpOverIp (3),
|
||||
mplsOverIp (4),
|
||||
mplsOverGre (5),
|
||||
other (6)
|
||||
}
|
||||
|
||||
IANAPwCapabilities ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This TC describes a collection of capabilities related to
|
||||
a specific PW.
|
||||
Values may be added in the future based on new capabilities
|
||||
introduced in IETF documents.
|
||||
"
|
||||
SYNTAX BITS {
|
||||
pwStatusIndication (0), -- Applicable only if maintenance
|
||||
-- protocol is in use.
|
||||
pwVCCV (1)
|
||||
}
|
||||
|
||||
END
|
2438
mibs/PW-STD-MIB
Normal file
2438
mibs/PW-STD-MIB
Normal file
File diff suppressed because it is too large
Load Diff
288
mibs/PW-TC-STD-MIB
Normal file
288
mibs/PW-TC-STD-MIB
Normal file
@ -0,0 +1,288 @@
|
||||
PW-TC-STD-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY, Unsigned32, mib-2
|
||||
FROM SNMPv2-SMI -- [RFC2578]
|
||||
|
||||
TEXTUAL-CONVENTION
|
||||
FROM SNMPv2-TC; -- [RFC2579]
|
||||
|
||||
pwTcStdMIB MODULE-IDENTITY
|
||||
LAST-UPDATED "200904210000Z" -- 21 April 2009 00:00:00 GMT
|
||||
ORGANIZATION "Pseudowire Edge-to-Edge Emulation (PWE3) Working
|
||||
Group"
|
||||
CONTACT-INFO
|
||||
" Thomas D. Nadeau
|
||||
Email: tom.nadeau@bt.com
|
||||
|
||||
David Zelig
|
||||
Email: davidz@oversi.com
|
||||
|
||||
Orly Nicklass
|
||||
Email: orlyn@radvision.com
|
||||
|
||||
The PWE3 Working Group (email distribution pwe3@ietf.org,
|
||||
http://www.ietf.org/html.charters/pwe3-charter.html)
|
||||
"
|
||||
DESCRIPTION
|
||||
"This MIB module defines TEXTUAL-CONVENTIONS
|
||||
for concepts used in pseudowire edge-to-edge
|
||||
networks.
|
||||
|
||||
Copyright (c) 2009 IETF Trust and the persons identified
|
||||
as authors of the code. All rights reserved.
|
||||
|
||||
Redistribution and use in source and binary forms, with or
|
||||
without modification, are permitted provided that the following
|
||||
conditions are met:
|
||||
|
||||
- Redistributions of source code must retain the above
|
||||
copyright notice, this list of conditions and the following
|
||||
disclaimer.
|
||||
|
||||
- Redistributions in binary form must reproduce the above
|
||||
copyright notice, this list of conditions and the following
|
||||
disclaimer in the documentation and/or other materials
|
||||
provided with the distribution.
|
||||
|
||||
- Neither the name of Internet Society, IETF or IETF Trust, nor
|
||||
the names of specific contributors, may be used to endorse or
|
||||
promote products derived from this software without specific
|
||||
prior written permission.
|
||||
|
||||
THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND
|
||||
CONTRIBUTORS 'AS IS' AND ANY EXPRESS OR IMPLIED WARRANTIES,
|
||||
INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
|
||||
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE
|
||||
DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR
|
||||
CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
|
||||
SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT
|
||||
NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;
|
||||
LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
|
||||
HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN
|
||||
CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR
|
||||
OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE,
|
||||
EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
|
||||
|
||||
This version of this MIB module is part of RFC 5542;
|
||||
see the RFC itself for full legal notices."
|
||||
|
||||
-- Revision history.
|
||||
|
||||
REVISION "200904210000Z" -- 21 April 2009 00:00:00 GMT
|
||||
DESCRIPTION
|
||||
"Original Version"
|
||||
::= { mib-2 188 }
|
||||
|
||||
PwGroupID ::= TEXTUAL-CONVENTION
|
||||
DISPLAY-HINT "d"
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An administrative identification for grouping a
|
||||
set of service-specific pseudowire services."
|
||||
SYNTAX Unsigned32
|
||||
|
||||
PwIDType ::= TEXTUAL-CONVENTION
|
||||
DISPLAY-HINT "d"
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Pseudowire Identifier. Used to identify the PW
|
||||
(together with some other fields) in the signaling
|
||||
session."
|
||||
SYNTAX Unsigned32
|
||||
|
||||
PwIndexType ::= TEXTUAL-CONVENTION
|
||||
DISPLAY-HINT "d"
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Pseudowire Index. A unique value, greater than zero,
|
||||
for each locally defined PW. Used for indexing
|
||||
several MIB tables associated with the particular PW.
|
||||
It is recommended that values are assigned contiguously
|
||||
starting from 1. The value for each PW MUST remain
|
||||
constant at least from one re-initialization
|
||||
to the next re-initialization."
|
||||
SYNTAX Unsigned32 (1..4294967295)
|
||||
|
||||
PwIndexOrZeroType ::= TEXTUAL-CONVENTION
|
||||
DISPLAY-HINT "d"
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This TEXTUAL-CONVENTION is an extension of the
|
||||
PwIndexType convention. The latter defines a greater-
|
||||
than-zero value used to identify a pseudowire
|
||||
in the managed system. This extension permits the
|
||||
additional value of zero. The zero value is object-specific
|
||||
and MUST therefore be defined as part of the description of
|
||||
any object that uses this syntax. Examples of the usage of
|
||||
zero might include situations where pseudowire was unknown,
|
||||
or where none or all pseudowires need to be referenced."
|
||||
SYNTAX Unsigned32 (0..4294967295)
|
||||
|
||||
PwOperStatusTC ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates the operational status of the PW.
|
||||
|
||||
- up(1): Ready to pass packets.
|
||||
- down(2): PW signaling is not yet finished, or
|
||||
indications available at the service
|
||||
level indicate that the PW is not
|
||||
passing packets.
|
||||
- testing(3): AdminStatus at the PW level is set to
|
||||
test.
|
||||
|
||||
- dormant(4): The PW is not in a condition to pass
|
||||
packets but is in a 'pending' state,
|
||||
waiting for some external event.
|
||||
- notPresent(5): Some component is missing to accomplish
|
||||
the setup of the PW. It can be
|
||||
configuration error, incomplete
|
||||
configuration, or a missing H/W component.
|
||||
- lowerLayerDown(6): One or more of the lower-layer interfaces
|
||||
responsible for running the underlying PSN
|
||||
is not in OperStatus 'up' state."
|
||||
SYNTAX INTEGER {
|
||||
up(1),
|
||||
down(2),
|
||||
testing(3),
|
||||
dormant(4),
|
||||
notPresent(5),
|
||||
lowerLayerDown(6)
|
||||
}
|
||||
|
||||
PwAttachmentIdentifierType ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An octet string used in the generalized Forward Error
|
||||
Correction (FEC) element for identifying attachment forwarder
|
||||
and groups. A NULL identifier is of zero length.
|
||||
"
|
||||
SYNTAX OCTET STRING (SIZE (0..255))
|
||||
|
||||
PwGenIdType ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Represents the Attachment Group Identifier (AGI) Type and
|
||||
Attachment Individual Identifier (AII) Type in generalized FEC
|
||||
signaling and configuration.
|
||||
"
|
||||
SYNTAX Unsigned32( 0..254 )
|
||||
|
||||
PwCwStatusTC ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates the status of the control word (CW) negotiation
|
||||
based on the local configuration and the indications received
|
||||
from the peer node.
|
||||
|
||||
waitingForNextMsg(1) indicates that the node is waiting for
|
||||
another label mapping from the peer.
|
||||
|
||||
sentWrongBitErrorCode(2) indicates that the local node has
|
||||
notified the peer about a mismatch in the C-bit.
|
||||
|
||||
rxWithdrawWithWrongBitErrorCode(3) indicates that a withdraw
|
||||
message has been received with the wrong C-bit error code.
|
||||
|
||||
illegalReceivedBit(4) indicates a C-bit configuration with
|
||||
the peer that is not compatible with the PW type.
|
||||
|
||||
cwPresent(5) indicates that the CW is present for this PW.
|
||||
If signaling is used, the C-bit is set and agreed upon between
|
||||
the nodes. For manually configured PW, the local
|
||||
configuration requires the use of the CW.
|
||||
|
||||
cwNotPresent(6) indicates that the CW is not present for this
|
||||
PW. If signaling is used, the C-bit is reset and agreed upon
|
||||
between the nodes. For manually configured PW, the local
|
||||
configuration requires that the CW not be used.
|
||||
|
||||
notYetKnown(7) indicates that a label mapping has not yet
|
||||
been received from the peer.
|
||||
"
|
||||
REFERENCE
|
||||
"Martini, et al., 'Pseudowire Setup and Maintenance Using
|
||||
the Label Distribution Protocol', [RFC4447]."
|
||||
SYNTAX INTEGER {
|
||||
waitingForNextMsg(1),
|
||||
sentWrongBitErrorCode(2),
|
||||
rxWithdrawWithWrongBitErrorCode(3),
|
||||
illegalReceivedBit(4),
|
||||
cwPresent(5),
|
||||
cwNotPresent(6),
|
||||
notYetKnown(7)
|
||||
}
|
||||
|
||||
PwStatus ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates the status of the PW and the interfaces affecting
|
||||
this PW. If none of the bits are set, it indicates no faults
|
||||
are reported.
|
||||
"
|
||||
SYNTAX BITS {
|
||||
pwNotForwarding(0),
|
||||
servicePwRxFault(1),
|
||||
servicePwTxFault(2),
|
||||
psnPwRxFault(3),
|
||||
psnPwTxFault(4)
|
||||
}
|
||||
|
||||
PwFragSize ::= TEXTUAL-CONVENTION
|
||||
DISPLAY-HINT "d"
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"If set to a value other than zero, it indicates the desired
|
||||
fragmentation length in bytes. If set to zero,
|
||||
fragmentation is not desired for PSN bound packets.
|
||||
"
|
||||
SYNTAX Unsigned32
|
||||
|
||||
PwFragStatus ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates the status of the fragmentation/reassembly process
|
||||
based on local configuration and peer capability.
|
||||
|
||||
noFrag(0) bit indicates that local configuration is for no
|
||||
fragmentation.
|
||||
|
||||
cfgFragGreaterThanPsnMtu(1) bit indicates that the local node
|
||||
is set to fragment, but the fragmentation size is greater
|
||||
than the MTU available at the PSN between the nodes.
|
||||
Fragmentation is not done in this case.
|
||||
|
||||
cfgFragButRemoteIncapable(2) bit indicates that the local
|
||||
configuration conveys the desire for fragmentation but
|
||||
the peer is not capable of reassembly.
|
||||
|
||||
remoteFragCapable(3) bit indicates that the remote node
|
||||
is capable to accept fragmented PDUs.
|
||||
|
||||
fragEnabled(4) bit indicates that fragmentation will be used
|
||||
on this PW. Fragmentation can be used if the local node was
|
||||
configured for fragmentation, the peer has the capability
|
||||
to accept fragmented packets, and the CW is in use for this
|
||||
PW."
|
||||
REFERENCE
|
||||
"Malis, A. and M. Townsley, 'Pseudowire Emulation Edge-to-
|
||||
Edge (PWE3) Fragmentation and Reassembly', [RFC4623]."
|
||||
SYNTAX BITS {
|
||||
noFrag(0),
|
||||
cfgFragGreaterThanPsnMtu(1),
|
||||
cfgFragButRemoteIncapable(2),
|
||||
remoteFragCapable(3),
|
||||
fragEnabled(4)
|
||||
}
|
||||
|
||||
PwCfgIndexOrzero ::= TEXTUAL-CONVENTION
|
||||
DISPLAY-HINT "d"
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Index in any of the relevant configuration tables for
|
||||
supplement information regarding configuration of the
|
||||
specific technology. Value zero implies no additional
|
||||
configuration information is applicable."
|
||||
SYNTAX Unsigned32 (0..4294967295)
|
||||
END
|
@ -2,6 +2,7 @@
|
||||
-- =======================================================================
|
||||
-- Version info
|
||||
--
|
||||
-- Version 1.0 modified 2020.4.17 by QiYianqin, add ROS Mgmt
|
||||
-- Version 1.0 modified 2012.4.18 by WangMingjuan, add gazelle series
|
||||
-- Version 1.0 modified 2011.12.14 by WangMingjuan
|
||||
-- Version 0.1 Created 2003.5.24 by GONGGUIDONG
|
||||
@ -13,7 +14,8 @@ RAISECOM-BASE-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
enterprises FROM RFC1155-SMI;
|
||||
|
||||
|
||||
|
||||
-- =======================================================================
|
||||
--
|
||||
-- Organization branches
|
||||
@ -98,14 +100,15 @@ IMPORTS
|
||||
gazelleRouterSeries OBJECT IDENTIFIER ::= { raisecom 28 }
|
||||
|
||||
-- SHENLANXUNTONG Series
|
||||
shenlanxuntongSeries OBJECT IDENTIFIER ::= { raisecom 29 }
|
||||
|
||||
shenlanxuntongSeries OBJECT IDENTIFIER ::= { raisecom 29 }
|
||||
-- SHENLANXUNTONG Transmit Series
|
||||
sltSeries OBJECT IDENTIFIER ::= { shenlanxuntongSeries 1 }
|
||||
|
||||
sltSeries OBJECT IDENTIFIER ::= { shenlanxuntongSeries 1 }
|
||||
|
||||
-- OTN Product Series
|
||||
otnSeries OBJECT IDENTIFIER ::= { raisecom 30 }
|
||||
OTNSeries OBJECT IDENTIFIER ::= { raisecom 30 }
|
||||
|
||||
--ROS Mgmt
|
||||
rosMgmt OBJECT IDENTIFIER ::= { raisecom 60 }
|
||||
|
||||
-- =======================================================================
|
||||
--
|
||||
|
495
mibs/raisecom/ROSMGMT-ALARM-MGMT-MIB
Normal file
495
mibs/raisecom/ROSMGMT-ALARM-MGMT-MIB
Normal file
@ -0,0 +1,495 @@
|
||||
--MibName=rosMgmtAlarm
|
||||
-- *****************************************************************
|
||||
-- ROSMGMT-ALARM-MGMT-MIB.mib: ROSMGMT ALARM MIB
|
||||
--
|
||||
-- April 2011, yangguodong
|
||||
--
|
||||
-- Copyright (c) 1996-2011 by Raisecom Technology Co., Ltd.
|
||||
-- All rights reserved.
|
||||
--
|
||||
-- *****************************************************************
|
||||
--
|
||||
|
||||
ROSMGMT-ALARM-MGMT-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY,OBJECT-TYPE,
|
||||
Unsigned32,Integer32
|
||||
FROM SNMPv2-SMI -- [RFC2578]
|
||||
TEXTUAL-CONVENTION,TruthValue
|
||||
FROM SNMPv2-TC -- [RFC2579]
|
||||
|
||||
SnmpAdminString
|
||||
FROM SNMP-FRAMEWORK-MIB -- [RFC3411]
|
||||
ifIndex FROM IF-MIB
|
||||
rosMgmt
|
||||
FROM RAISECOM-BASE-MIB;
|
||||
|
||||
rosMgmtAlarmMgmt MODULE-IDENTITY
|
||||
LAST-UPDATED "202006180000Z" -- 18 June 2020 00:00:00 GMT
|
||||
ORGANIZATION "Raisecom Technology Co., Ltd."
|
||||
CONTACT-INFO
|
||||
"Raisecom Science & Technology Co., ltd.
|
||||
E-mail: support@rosMgmt.com ."
|
||||
DESCRIPTION
|
||||
"This MIB module contains managed object definitions for
|
||||
MPLS. "
|
||||
REVISION "202006180000Z" -- 18 June 2020 00:00:00 GMT
|
||||
DESCRIPTION
|
||||
"Add alarm reversal mode to automatically flip state."
|
||||
REVISION "201103120000Z" -- 12 March 2011 00:00:00 GMT
|
||||
DESCRIPTION
|
||||
"ROSMGMT ALARM MIB initial version."
|
||||
::= { rosMgmt 34 }
|
||||
--rosMgmtAlarmMgmt 0 notification
|
||||
rosMgmtAlarmMgmtObejcts OBJECT IDENTIFIER ::= { rosMgmtAlarmMgmt 1 }
|
||||
--rosMgmtAlarmMgmt 2 conformance group
|
||||
-- User-defined types
|
||||
AlarmStorageMode ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Describes how to store alarm active table when the alarm
|
||||
table was full.When the storage mode is stop,the new raised
|
||||
alarm will be discarded.It will not insert to alarm active table.
|
||||
If the storage mode is loop,the oldest row in alarm active table
|
||||
will be deleted and the the newly raiseco alarm will be inserted
|
||||
to the alarm active table."
|
||||
|
||||
SYNTAX INTEGER {
|
||||
stop(1), -- eh?
|
||||
loop(2) -- e.g., in RAM
|
||||
}
|
||||
|
||||
AlarmInverseMode ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Describes the mode of alarm inverse "
|
||||
|
||||
SYNTAX INTEGER {
|
||||
none(1), -- inverse mode is non
|
||||
auto(2), -- inverse mode is auto
|
||||
manual(3), -- inverse mode is manual
|
||||
autofinish(4) -- inverse mode is auto finish
|
||||
}
|
||||
--end user defined type
|
||||
|
||||
--start of alarm config
|
||||
rosMgmtAlarmMgmtScalarGroup OBJECT IDENTIFIER ::= { rosMgmtAlarmMgmtObejcts 1 }
|
||||
rosMgmtAlarmMgmtRaiseDelay OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..600)
|
||||
UNITS "seconds"
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The approximate period from the time a alarm was
|
||||
raised to a time this alarm was reported."
|
||||
DEFVAL { 0 }
|
||||
::= { rosMgmtAlarmMgmtScalarGroup 1}
|
||||
|
||||
rosMgmtAlarmMgmtClearDelay OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..600)
|
||||
UNITS "seconds"
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The approximate period from the time a alarm was
|
||||
cleared to a time this alarm report."
|
||||
DEFVAL { 0 }
|
||||
::= { rosMgmtAlarmMgmtScalarGroup 2 }
|
||||
|
||||
rosMgmtAlarmMgmtActiveStoreMode OBJECT-TYPE
|
||||
SYNTAX AlarmStorageMode
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The storage mode of the alarm active table"
|
||||
::= { rosMgmtAlarmMgmtScalarGroup 3 }
|
||||
|
||||
rosMgmtAlarmMgmtInhibitEnable OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Enable or Disable Alarm Inhibit"
|
||||
DEFVAL { true }
|
||||
::= { rosMgmtAlarmMgmtScalarGroup 4 }
|
||||
|
||||
rosMgmtAlarmMgmtSyslogEnable OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Enable or Disable write syslog when an alarm raise"
|
||||
DEFVAL { true }
|
||||
::= { rosMgmtAlarmMgmtScalarGroup 5 }
|
||||
|
||||
rosMgmtAlarmMgmtActiveClear OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"clear active alarm according to the active table third index"
|
||||
::= { rosMgmtAlarmMgmtScalarGroup 6 }
|
||||
|
||||
|
||||
rosMgmtAlarmMgmtConfigTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RosMgmtAlarmMgmtConfigEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table specifies the information of alarm configuration."
|
||||
::= { rosMgmtAlarmMgmtObejcts 2 }
|
||||
|
||||
rosMgmtAlarmMgmtConfigEntry OBJECT-TYPE
|
||||
SYNTAX RosMgmtAlarmMgmtConfigEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A row in this table represents the configuration of specified alarm."
|
||||
INDEX { rosMgmtAlarmMgmtId,ifIndex }
|
||||
::= { rosMgmtAlarmMgmtConfigTable 1 }
|
||||
|
||||
RosMgmtAlarmMgmtConfigEntry ::= SEQUENCE {
|
||||
rosMgmtAlarmMgmtId Unsigned32,
|
||||
rosMgmtAlarmMgmtClear TruthValue,
|
||||
rosMgmtAlarmMgmtReportEnable TruthValue,
|
||||
rosMgmtAlarmMgmtMonitorEnable TruthValue,
|
||||
rosMgmtAlarmMgmtInverseMode AlarmInverseMode,
|
||||
rosMgmtAlarmMgmtModuleName SnmpAdminString,
|
||||
rosMgmtAlarmMgmtGroupName SnmpAdminString
|
||||
}
|
||||
|
||||
rosMgmtAlarmMgmtId OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"First index of alarm config table which is equal to alarm group Id"
|
||||
::= { rosMgmtAlarmMgmtConfigEntry 1 }
|
||||
|
||||
rosMgmtAlarmMgmtClear OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The swith of alarm clear,when open the swith the related
|
||||
active alarm entry will be deleted from alarm active table"
|
||||
DEFVAL { false }
|
||||
::= { rosMgmtAlarmMgmtConfigEntry 2 }
|
||||
|
||||
rosMgmtAlarmMgmtReportEnable OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Enable or disable Alarm Report"
|
||||
DEFVAL { true }
|
||||
::= { rosMgmtAlarmMgmtConfigEntry 3 }
|
||||
|
||||
rosMgmtAlarmMgmtMonitorEnable OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Enable or disable alarm monitor"
|
||||
DEFVAL { true }
|
||||
::= { rosMgmtAlarmMgmtConfigEntry 4 }
|
||||
|
||||
rosMgmtAlarmMgmtInverseMode OBJECT-TYPE
|
||||
SYNTAX AlarmInverseMode
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The mode of alarm inverse"
|
||||
DEFVAL { none }
|
||||
::= { rosMgmtAlarmMgmtConfigEntry 5 }
|
||||
|
||||
rosMgmtAlarmMgmtModuleName OBJECT-TYPE
|
||||
SYNTAX SnmpAdminString (SIZE(0..32))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The module name which this alarm belongs to."
|
||||
::= { rosMgmtAlarmMgmtConfigEntry 6 }
|
||||
|
||||
rosMgmtAlarmMgmtGroupName OBJECT-TYPE
|
||||
SYNTAX SnmpAdminString (SIZE(0..32))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The name of alarm group."
|
||||
::= { rosMgmtAlarmMgmtConfigEntry 7 }
|
||||
|
||||
rosMgmtAlarmMgmtCfgTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RosMgmtAlarmMgmtCfgEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table specifies the information of alarm configuration."
|
||||
::= { rosMgmtAlarmMgmtObejcts 3 }
|
||||
|
||||
rosMgmtAlarmMgmtCfgEntry OBJECT-TYPE
|
||||
SYNTAX RosMgmtAlarmMgmtCfgEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A row in this table represents the configuration of specified alarm."
|
||||
INDEX { rosMgmtAlarmMgmtCfgAlarmType,rosMgmtAlarmMgmtCfgAlarmResType,rosMgmtAlarmMgmtCfgAlarmRes}
|
||||
::= { rosMgmtAlarmMgmtCfgTable 1 }
|
||||
|
||||
RosMgmtAlarmMgmtCfgEntry ::= SEQUENCE {
|
||||
rosMgmtAlarmMgmtCfgAlarmType Unsigned32,
|
||||
rosMgmtAlarmMgmtCfgAlarmResType INTEGER,
|
||||
rosMgmtAlarmMgmtCfgAlarmRes Unsigned32,
|
||||
rosMgmtAlarmMgmtCfgClear TruthValue,
|
||||
rosMgmtAlarmMgmtCfgMonitorEnable TruthValue,
|
||||
rosMgmtAlarmMgmtCfgReportEnable TruthValue,
|
||||
rosMgmtAlarmMgmtCfgInverseMode AlarmInverseMode
|
||||
}
|
||||
|
||||
rosMgmtAlarmMgmtCfgAlarmType OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Third index of alarm Mgmt config table.The type of Alarm."
|
||||
::= { rosMgmtAlarmMgmtCfgEntry 1 }
|
||||
|
||||
rosMgmtAlarmMgmtCfgAlarmResType OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
slotindex(1), --告警源:板卡
|
||||
pwindex(2), --告警源:PW
|
||||
lspindex(3), --告警源:LSP
|
||||
loifindex(4), --告警源:LOOPBACK口
|
||||
agifindex(5), --告警源:AG口
|
||||
apifindex(6), --告警源:AP口
|
||||
obifindex(7), --告警源:OUTBAND口
|
||||
tdmifindex(8), --告警源:TDM口
|
||||
tunnelifindex(9), --告警源:TRUNK口
|
||||
vlanifindex(10), --告警源:VLAN口
|
||||
subifindex(11), --告警源:SUBIF口
|
||||
portindex(12), --告警源:端口
|
||||
apagsubifindex(13), --告警源:AP,AG,子接口
|
||||
powerindex(14), --告警源:电源
|
||||
fanindex(15), --告警源:风扇
|
||||
boardindex(16), --告警源:板卡,电源,风扇
|
||||
cfmindex(17),
|
||||
erpsindex(18),
|
||||
apsindex(19),
|
||||
bfdindex(20),
|
||||
ldpindex(21),
|
||||
lsaindex(22),
|
||||
ifindex(23),
|
||||
cpuindex(24),
|
||||
tdmsubifindex(25),
|
||||
tdmtdmsubifindex(26),
|
||||
stmifindex(27),
|
||||
stmsubifindex(28),
|
||||
stmsubtdmtdmsubindex(29),
|
||||
stmvcindex(30),
|
||||
eponifindex(31),
|
||||
eonuifindex(32),
|
||||
eonusubifindex(33),
|
||||
apeponifindex(34),
|
||||
apagvlansubifindex(35)
|
||||
}
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"First index of alarm Mgmt config table.The type of Alarm Resoure."
|
||||
::= { rosMgmtAlarmMgmtCfgEntry 2 }
|
||||
|
||||
rosMgmtAlarmMgmtCfgAlarmRes OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Second index of alarm Mgmt config table.The value of Alarm Resoure."
|
||||
::= { rosMgmtAlarmMgmtCfgEntry 3 }
|
||||
|
||||
rosMgmtAlarmMgmtCfgClear OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The swith of alarm clear,when open the swith, the related active alarm entry will be deleted from alarm active table."
|
||||
DEFVAL { false }
|
||||
::= { rosMgmtAlarmMgmtCfgEntry 4 }
|
||||
|
||||
rosMgmtAlarmMgmtCfgMonitorEnable OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Enable or disable alarm Monitor."
|
||||
DEFVAL { true }
|
||||
::= { rosMgmtAlarmMgmtCfgEntry 5 }
|
||||
|
||||
rosMgmtAlarmMgmtCfgReportEnable OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Enable or disable alarm Report."
|
||||
DEFVAL { true }
|
||||
::= { rosMgmtAlarmMgmtCfgEntry 6 }
|
||||
|
||||
rosMgmtAlarmMgmtCfgInverseMode OBJECT-TYPE
|
||||
SYNTAX AlarmInverseMode
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Alarm Inverse Mode."
|
||||
DEFVAL { none }
|
||||
::= { rosMgmtAlarmMgmtCfgEntry 7 }
|
||||
|
||||
--end of alarm config
|
||||
|
||||
rosMgmtAlarmMgmtMonitorLevel OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
clear(1),
|
||||
indeterminate(2),
|
||||
critical(3),
|
||||
major(4),
|
||||
minor(5),
|
||||
warning(6)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The level of Alarm Monitor."
|
||||
DEFVAL { minor }
|
||||
::= { rosMgmtAlarmMgmtScalarGroup 7}
|
||||
|
||||
rosMgmtAlarmMgmtClearLevel OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
clear(1),
|
||||
indeterminate(2),
|
||||
critical(3),
|
||||
major(4),
|
||||
minor(5),
|
||||
warning(6)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The level of Alarm Monitor."
|
||||
::= { rosMgmtAlarmMgmtScalarGroup 8}
|
||||
|
||||
rosMgmtAlarmMgmtMonitor OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Enable or Disable Alarm Monitor."
|
||||
DEFVAL { true }
|
||||
::= { rosMgmtAlarmMgmtScalarGroup 9 }
|
||||
|
||||
|
||||
rosMgmtAlarmMgmtCorrelationInhibit OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Enable or Disable Alarm CorrelationInhibit."
|
||||
DEFVAL { true }
|
||||
::= { rosMgmtAlarmMgmtScalarGroup 10 }
|
||||
|
||||
rosMgmtAlarmMgmtReport OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Enable or Disable Alarm Report."
|
||||
DEFVAL { true }
|
||||
::= { rosMgmtAlarmMgmtScalarGroup 11 }
|
||||
|
||||
-- rosMgmtAlarmMgmtCfgOutPutTable OBJECT-TYPE
|
||||
-- SYNTAX SEQUENCE OF RaisecomAlarmMgmtCfgOutPutEntry
|
||||
-- MAX-ACCESS not-accessible
|
||||
-- STATUS current
|
||||
-- DESCRIPTION
|
||||
-- "This table specifies the information of alarm configuration."
|
||||
-- ::= { rosMgmtAlarmMgmtObejcts 14 }
|
||||
--
|
||||
-- rosMgmtAlarmMgmtCfgOutPutEntry OBJECT-TYPE
|
||||
-- SYNTAX RaisecomAlarmMgmtCfgOutPutEntry
|
||||
-- MAX-ACCESS not-accessible
|
||||
-- STATUS current
|
||||
-- DESCRIPTION
|
||||
-- "A row in this table represents the configuration of specified alarm."
|
||||
-- INDEX { rosMgmtAlarmMgmtAlarmOutputGroupIndex, rosMgmtAlarmMgmtAlarmOutputType}
|
||||
-- ::= { rosMgmtAlarmMgmtCfgOutPutTable 1 }
|
||||
--
|
||||
-- RaisecomAlarmMgmtCfgOutPutEntry ::= SEQUENCE {
|
||||
-- rosMgmtAlarmMgmtAlarmOutputGroupIndex INTEGER,
|
||||
-- rosMgmtAlarmMgmtAlarmOutputType Unsigned32,
|
||||
-- rosMgmtAlarmMgmtAlarmOutputRowStatus TruthValue
|
||||
-- }
|
||||
--
|
||||
-- rosMgmtAlarmMgmtAlarmOutputGroupIndex OBJECT-TYPE
|
||||
-- SYNTAX INTEGER (1..2)
|
||||
-- MAX-ACCESS not-accessible
|
||||
-- STATUS current
|
||||
-- DESCRIPTION
|
||||
-- "The index of alarm Mgmt OutputGroup table."
|
||||
-- ::= { rosMgmtAlarmMgmtCfgOutPutEntry 1}
|
||||
--
|
||||
-- rosMgmtAlarmMgmtAlarmOutputType OBJECT-TYPE
|
||||
-- SYNTAX Unsigned32
|
||||
-- MAX-ACCESS not-accessible
|
||||
-- STATUS current
|
||||
-- DESCRIPTION
|
||||
-- "Third index of alarm Mgmt config table.The type of Alarm."
|
||||
-- ::= { rosMgmtAlarmMgmtCfgOutPutEntry 2 }
|
||||
--
|
||||
-- rosMgmtAlarmMgmtAlarmOutputRowStatus OBJECT-TYPE
|
||||
-- SYNTAX TruthValue
|
||||
-- MAX-ACCESS read-write
|
||||
-- STATUS current
|
||||
-- DESCRIPTION
|
||||
-- "Enable or disable Alarm Output"
|
||||
-- DEFVAL { true }
|
||||
-- ::= { rosMgmtAlarmMgmtCfgOutPutEntry 3}
|
||||
--
|
||||
--
|
||||
-- rosMgmtAlarmMgmtCfgOutPutGroupTable OBJECT-TYPE
|
||||
-- SYNTAX SEQUENCE OF RaisecomAlarmMgmtCfgOutPutGroupEntry
|
||||
-- MAX-ACCESS not-accessible
|
||||
-- STATUS current
|
||||
-- DESCRIPTION
|
||||
-- "This table specifies the information of alarm configuration."
|
||||
-- ::= { rosMgmtAlarmMgmtObejcts 15 }
|
||||
--
|
||||
-- rosMgmtAlarmMgmtCfgOutPutGroupEntry OBJECT-TYPE
|
||||
-- SYNTAX RaisecomAlarmMgmtCfgOutPutGroupEntry
|
||||
-- MAX-ACCESS not-accessible
|
||||
-- STATUS current
|
||||
-- DESCRIPTION
|
||||
-- "A row in this table represents the configuration of specified alarm."
|
||||
-- INDEX { rosMgmtAlarmMgmtAlarmOutputgrpIndex}
|
||||
-- ::= { rosMgmtAlarmMgmtCfgOutPutGroupTable 1 }
|
||||
--
|
||||
-- RaisecomAlarmMgmtCfgOutPutGroupEntry ::= SEQUENCE {
|
||||
-- rosMgmtAlarmMgmtAlarmOutputgrpIndex INTEGER,
|
||||
-- rosMgmtAlarmMgmtAlarmOutputEnable EnableVar
|
||||
-- }
|
||||
--
|
||||
-- rosMgmtAlarmMgmtAlarmOutputgrpIndex OBJECT-TYPE
|
||||
-- SYNTAX INTEGER (1..2)
|
||||
-- MAX-ACCESS not-accessible
|
||||
-- STATUS current
|
||||
-- DESCRIPTION
|
||||
-- "The index of alarm Mgmt OutputGroup table."
|
||||
-- ::= { rosMgmtAlarmMgmtCfgOutPutGroupEntry 1}
|
||||
--
|
||||
-- rosMgmtAlarmMgmtAlarmOutputEnable OBJECT-TYPE
|
||||
-- SYNTAX EnableVar
|
||||
-- MAX-ACCESS read-write
|
||||
-- STATUS current
|
||||
-- DESCRIPTION
|
||||
-- "Third index of alarm Mgmt config table.The type of Alarm."
|
||||
-- ::= { rosMgmtAlarmMgmtCfgOutPutGroupEntry 2 }
|
||||
|
||||
|
||||
END
|
141
mibs/raisecom/ROSMGMT-COMMON-MANAGEMENT-MIB
Normal file
141
mibs/raisecom/ROSMGMT-COMMON-MANAGEMENT-MIB
Normal file
@ -0,0 +1,141 @@
|
||||
--MibName=raisecomCommonManagement
|
||||
-- =======================================================================
|
||||
-- Version info
|
||||
--
|
||||
-- Version 0.1 Created 2002.5.24 by GONGGUIDONG
|
||||
-- This version of MIB is created just for management of base and user.
|
||||
-- Added raisecomClockGroup.raisecomClockMode sub-node by XueChaomin 20081220
|
||||
-- remove UserManage and OnlineUpgrade group by guoxiaodan 20070716
|
||||
-- removed keepalve group by LIAOBIN 20070709
|
||||
-- raisecomEnableLogMethod add localradius radiuslocal by yjg 20070112
|
||||
-- modify RaisecomUserEntry by cjy 20060616
|
||||
-- add raisecomEnableLogPassword¡¢raisecomEnableLogOldPassword by cjy 20060616
|
||||
-- add rcNotificationGroup by gongguidong 20041208
|
||||
-- add raisecomUserStatus by gongguidong 20040205
|
||||
-- add online Upgrade group by gongguidong 20040205
|
||||
-- Copyright(c) 2003-2005 by RAISECOM TECH, Ltd.
|
||||
-- =======================================================================
|
||||
|
||||
-- ===========================================================================
|
||||
|
||||
--
|
||||
-- RAISECOM base management objects
|
||||
--
|
||||
|
||||
ROSMGMT-COMMON-MANAGEMENT-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY,
|
||||
OBJECT-TYPE,
|
||||
NOTIFICATION-TYPE ,
|
||||
Integer32
|
||||
FROM SNMPv2-SMI
|
||||
TruthValue
|
||||
FROM SNMPv2-TC
|
||||
EnableVar
|
||||
FROM SWITCH-TC
|
||||
rosMgmt
|
||||
FROM RAISECOM-BASE-MIB;
|
||||
|
||||
rosMgmtCommonManagement MODULE-IDENTITY
|
||||
LAST-UPDATED "202004120000Z"
|
||||
ORGANIZATION "RAISECOM TECH, Ltd."
|
||||
CONTACT-INFO "www.raisecom.com"
|
||||
DESCRIPTION
|
||||
"The MIB module defining objects for common management"
|
||||
REVISION "202004120000Z"
|
||||
DESCRIPTION "MIB file check and modification"
|
||||
::= { rosMgmt 2}
|
||||
|
||||
rosMgmtCommonFunctionGroup OBJECT IDENTIFIER ::= {rosMgmtCommonManagement 1}
|
||||
|
||||
rosMgmtCommonNotifications OBJECT IDENTIFIER ::= { rosMgmtCommonFunctionGroup 0 }
|
||||
rosMgmtCommonObjects OBJECT IDENTIFIER ::= { rosMgmtCommonFunctionGroup 1 }
|
||||
rosMgmtCommonConformance OBJECT IDENTIFIER ::= { rosMgmtCommonFunctionGroup 2 }
|
||||
|
||||
rosMgmtLoadcfg OBJECT IDENTIFIER ::= { rosMgmtCommonObjects 1 }
|
||||
rosMgmtAutoWrite OBJECT IDENTIFIER ::= { rosMgmtCommonObjects 2 }
|
||||
|
||||
|
||||
rosMgmtLoadcfgScalar OBJECT IDENTIFIER ::= { rosMgmtLoadcfg 1 }
|
||||
|
||||
rosMgmtConfigLoadOperation OBJECT-TYPE
|
||||
SYNTAX INTEGER{
|
||||
ready(1),
|
||||
saving(2),
|
||||
erasing(3),
|
||||
reboot(4),
|
||||
restore(5),
|
||||
reload(6),
|
||||
backupsaving(7),
|
||||
cpoyStaConf2BackConf(8),
|
||||
cpoyBackConf2StaConf(9),
|
||||
switStaConfBackConf(10),
|
||||
backuperasing(11),
|
||||
eraseStartupconfig(12),
|
||||
eraseStartupconfigAll(13),
|
||||
savingall(14)}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "Syetem Load Configuration .Includes to erase the start-up config,
|
||||
or to save the running config."
|
||||
::= { rosMgmtLoadcfgScalar 1 }
|
||||
|
||||
rosMgmtConfigLoadNotificationOnCompletion OBJECT-TYPE
|
||||
SYNTAX TruthValue
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Specifies whether or not a raisecomConfigLoadOnCompletion
|
||||
notification should be issued on completion of some
|
||||
operation . If such a notification is desired, it is the
|
||||
responsibility of the management entity to ensure that the
|
||||
SNMP administrative model is configured in such a way as to
|
||||
allow the notification to be delivered."
|
||||
DEFVAL { false }
|
||||
::= { rosMgmtLoadcfgScalar 2 }
|
||||
|
||||
rosMgmtConfigLoadState OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
ready(1),
|
||||
running(2),
|
||||
successful(3),
|
||||
failed(4)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Specifies the state of this load configuration."
|
||||
::= { rosMgmtLoadcfgScalar 3 }
|
||||
|
||||
|
||||
|
||||
rosMgmtAutoWritecfgEnable OBJECT-TYPE
|
||||
SYNTAX EnableVar
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION "Set/get auto writing configuration status."
|
||||
DEFVAL { enable }
|
||||
::= { rosMgmtAutoWrite 1 }
|
||||
|
||||
rosMgmtAutoWritecfgInterval OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
" Interval time of auto save module."
|
||||
::= { rosMgmtAutoWrite 2 }
|
||||
|
||||
rosMgmtConfigLoadCompletion NOTIFICATION-TYPE
|
||||
OBJECTS {
|
||||
rosMgmtConfigLoadOperation,
|
||||
rosMgmtConfigLoadState }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A raisecomConfigLoadeCompletion trap is sent when saving
|
||||
or erasing the configuration file. "
|
||||
::= { rosMgmtCommonNotifications 1}
|
||||
|
||||
END
|
||||
|
||||
|
142
mibs/raisecom/ROSMGMT-MEMORY-MIB
Normal file
142
mibs/raisecom/ROSMGMT-MEMORY-MIB
Normal file
@ -0,0 +1,142 @@
|
||||
--MibName=rosMgmtMemory
|
||||
-- =======================================================================
|
||||
-- Version info
|
||||
--
|
||||
-- Version 0.1 Created 2003.12.17 by GONGGUIDONG
|
||||
-- This version of MIB is created just for the use of Network Management Systems
|
||||
-- display the memory and cpu.
|
||||
--
|
||||
-- Copyright(c) 2002-2005 by RAISECOM TECH, Ltd.
|
||||
--
|
||||
-- =======================================================================
|
||||
|
||||
ROSMGMT-MEMORY-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY,
|
||||
NOTIFICATION-TYPE,
|
||||
OBJECT-TYPE,
|
||||
Integer32
|
||||
FROM SNMPv2-SMI
|
||||
EnableVar
|
||||
FROM SWITCH-TC
|
||||
rosMgmtSystem
|
||||
FROM ROSMGMT-SYSTEM-MIB;
|
||||
|
||||
rosMgmtMemory MODULE-IDENTITY
|
||||
LAST-UPDATED "202004120000Z"
|
||||
ORGANIZATION "RAISECOM TECH, Ltd."
|
||||
CONTACT-INFO "www.raisecom.com"
|
||||
DESCRIPTION
|
||||
"raisecom System objects: memory objects."
|
||||
REVISION "202004120000Z"
|
||||
DESCRIPTION "MIB file check and modification"
|
||||
::= { rosMgmtSystem 3 }
|
||||
|
||||
|
||||
rosMgmtMemoryNotifications OBJECT IDENTIFIER ::= { rosMgmtMemory 0 }
|
||||
rosMgmtMemoryObjects OBJECT IDENTIFIER ::= { rosMgmtMemory 1 }
|
||||
rosMgmtMemoryConformance OBJECT IDENTIFIER ::= { rosMgmtMemory 2 }
|
||||
|
||||
-- 1.3.6.1.4.1.8886.60.1.3.0.1
|
||||
rosMgmtMemoryTrap NOTIFICATION-TYPE
|
||||
OBJECTS { rosMgmtMemoryTotal, rosMgmtMemoryUtil, rosMgmtMemoryThrshd }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Trap transfer when memory utilization upon threshold."
|
||||
::= { rosMgmtMemoryNotifications 1 }
|
||||
|
||||
|
||||
-- 1.3.6.1.4.1.8886.60.1.3.0.2
|
||||
rosMgmtMemoryTrapRecover NOTIFICATION-TYPE
|
||||
OBJECTS { rosMgmtMemoryTotal, rosMgmtMemoryUtil,rosMgmtMemoryThrshdRecover }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Trap transfer when memory utilization upon thresholdrecover."
|
||||
::= { rosMgmtMemoryNotifications 2 }
|
||||
|
||||
|
||||
--
|
||||
-- rosMgmtMemoryScalarGroup
|
||||
--
|
||||
-- 1.3.6.1.4.1.8886.60.1.3.1.1
|
||||
rosMgmtMemoryScalarGroup OBJECT IDENTIFIER ::= { rosMgmtMemoryObjects 1 }
|
||||
|
||||
|
||||
-- 1.3.6.1.4.1.8886.60.1.3.1.1.1
|
||||
rosMgmtMemoryTotal OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "KB"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The total memory of the system for this duration."
|
||||
::= { rosMgmtMemoryScalarGroup 1 }
|
||||
|
||||
|
||||
-- 1.3.6.1.4.1.8886.60.1.3.1.1.2
|
||||
rosMgmtMemoryAvailable OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "KB"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The available memory of the system for this duration."
|
||||
::= { rosMgmtMemoryScalarGroup 2 }
|
||||
|
||||
|
||||
-- 1.3.6.1.4.1.8886.60.1.3.1.1.3
|
||||
rosMgmtMemoryUtil OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE (1..8))
|
||||
UNITS "percent"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The current value of memory utilization for this duration."
|
||||
::= { rosMgmtMemoryScalarGroup 3 }
|
||||
|
||||
|
||||
-- 1.3.6.1.4.1.8886.60.1.3.1.1.4
|
||||
rosMgmtMemoryTrapEnable OBJECT-TYPE
|
||||
SYNTAX EnableVar
|
||||
MAX-ACCESS read-write
|
||||
STATUS deprecated
|
||||
DESCRIPTION
|
||||
"The switch of memory trap."
|
||||
::= { rosMgmtMemoryScalarGroup 4 }
|
||||
|
||||
|
||||
-- 1.3.6.1.4.1.8886.60.1.3.1.1.5
|
||||
rosMgmtMemoryThrshd OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "percent"
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The threshold of memory monitor."
|
||||
::= { rosMgmtMemoryScalarGroup 5 }
|
||||
|
||||
|
||||
-- 1.3.6.1.4.1.8886.60.1.3.1.1.6
|
||||
rosMgmtMemoryThrshdRecover OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "percent"
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The recover threshold of memory monitor."
|
||||
::= { rosMgmtMemoryScalarGroup 6 }
|
||||
|
||||
|
||||
-- 1.3.6.1.4.1.8886.60.1.3.1.1.7
|
||||
rosMgmtMemoryMonInterval OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "second"
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The timer interval of memory monitor."
|
||||
::= { rosMgmtMemoryScalarGroup 7 }
|
||||
|
||||
|
||||
END
|
2251
mibs/raisecom/ROSMGMT-OPTICAL-TRANSCEIVER-MIB
Normal file
2251
mibs/raisecom/ROSMGMT-OPTICAL-TRANSCEIVER-MIB
Normal file
File diff suppressed because it is too large
Load Diff
4683
mibs/raisecom/ROSMGMT-OSPFv2-MIB
Normal file
4683
mibs/raisecom/ROSMGMT-OSPFv2-MIB
Normal file
File diff suppressed because it is too large
Load Diff
675
mibs/raisecom/ROSMGMT-SYSTEM-MIB
Normal file
675
mibs/raisecom/ROSMGMT-SYSTEM-MIB
Normal file
@ -0,0 +1,675 @@
|
||||
--MibName=raisecomSystem
|
||||
-- =======================================================================
|
||||
-- Version info
|
||||
--
|
||||
-- Version 0.1 Created 2003.12.17 by GONGGUIDONG
|
||||
-- This version of MIB is created just for the use of Network Management Systems
|
||||
-- display the memory and cpu.
|
||||
--
|
||||
-- Copyright(c) 2002-2005 by RAISECOM TECH, Ltd.
|
||||
-- modify history
|
||||
-- 01, 20131012, huxiangfeng, Add two traps.
|
||||
-- 01, 20090915, qiyun, Add CPU monitor MIBs.
|
||||
--
|
||||
-- =======================================================================
|
||||
|
||||
|
||||
|
||||
ROSMGMT-SYSTEM-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY ,
|
||||
NOTIFICATION-TYPE,
|
||||
Integer32,
|
||||
OBJECT-TYPE
|
||||
FROM SNMPv2-SMI
|
||||
rosMgmt
|
||||
FROM RAISECOM-BASE-MIB
|
||||
|
||||
EnableVar
|
||||
FROM SWITCH-TC
|
||||
TimeStamp,TEXTUAL-CONVENTION
|
||||
FROM SNMPv2-TC;
|
||||
|
||||
rosMgmtSystem MODULE-IDENTITY
|
||||
LAST-UPDATED "202004120000Z"
|
||||
ORGANIZATION "RAISECOM TECH, Ltd."
|
||||
CONTACT-INFO "www.raisecom.com"
|
||||
DESCRIPTION
|
||||
"raisecom System objects: objects common to all platforms."
|
||||
REVISION "202004120000Z"
|
||||
DESCRIPTION "MIB file check and modification"
|
||||
::= { rosMgmt 1 }
|
||||
--
|
||||
-- Textual Conventions
|
||||
--
|
||||
|
||||
ProcessStatus ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Status of the process."
|
||||
SYNTAX INTEGER
|
||||
{
|
||||
rrunning(1),
|
||||
dinterruptiblesleep(2),
|
||||
suninterruptiblesleep(3),
|
||||
tstopped(4),
|
||||
zzombie(5),
|
||||
xdead(6),
|
||||
wpaging(7)
|
||||
}
|
||||
|
||||
CPUTimeStamp ::= TEXTUAL-CONVENTION
|
||||
DISPLAY-HINT "4d.4d.4d.4d"
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The time in seconds that could represent signed
|
||||
quantities like time delay with respect to some
|
||||
source. The signed integer part is in the first
|
||||
32 bits and the fraction part is in the last 32 bits."
|
||||
REFERENCE
|
||||
"D.L. Mills, 'Network Time Protocol (Version 3)',
|
||||
RFC-1305, March 1992, Sections 2, 3.2.1"
|
||||
SYNTAX OCTET STRING (SIZE (16))
|
||||
|
||||
|
||||
--
|
||||
-- RAISECOM CPU objects
|
||||
--
|
||||
|
||||
|
||||
rosMgmtCpu OBJECT IDENTIFIER ::= { rosMgmtSystem 1 }
|
||||
|
||||
--rosMgmtCpuTrapGroup
|
||||
|
||||
rosMgmtCpuNotifications OBJECT IDENTIFIER ::= { rosMgmtCpu 0 }
|
||||
rosMgmtCpuObjects OBJECT IDENTIFIER ::= { rosMgmtCpu 1 }
|
||||
rosMgmtCpuConformance OBJECT IDENTIFIER ::= { rosMgmtCpu 2 }
|
||||
|
||||
--rosMgmtCpuNotifications
|
||||
rosMgmtCpuRisingThreshold NOTIFICATION-TYPE
|
||||
OBJECTS { rosMgmtProcessIndex, rosMgmtProcessUtilization,rosMgmtCpuUtilizationCpuIdx, rosMgmtCpuUtilization }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"CPU utilization rising threshold trap transfer."
|
||||
::= { rosMgmtCpuNotifications 1 }
|
||||
|
||||
rosMgmtCpuRisingThresholdRecover NOTIFICATION-TYPE
|
||||
OBJECTS {rosMgmtCpuUtilizationCpuIdx, rosMgmtCpuUtilization }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"CPU utilization rising threshold return to normal trap transfer."
|
||||
::= { rosMgmtCpuNotifications 2 }
|
||||
|
||||
|
||||
--rosMgmtCpuScalarGroup
|
||||
|
||||
|
||||
rosMgmtCpuScalarGroup OBJECT IDENTIFIER
|
||||
::= { rosMgmtCpuObjects 1}
|
||||
|
||||
rosMgmtCpuTotalProcNum OBJECT-TYPE
|
||||
SYNTAX Integer32 (1..2000)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Total number of processes."
|
||||
::= { rosMgmtCpuScalarGroup 1}
|
||||
|
||||
|
||||
rosMgmtCpuHistoryTableSize OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A value configured by the user which specifies
|
||||
the number of reports in the history table."
|
||||
DEFVAL { 60 }
|
||||
::= { rosMgmtCpuScalarGroup 2}
|
||||
|
||||
rosMgmtCpuThresholdTrapEnable OBJECT-TYPE
|
||||
SYNTAX EnableVar
|
||||
MAX-ACCESS read-write
|
||||
STATUS deprecated
|
||||
DESCRIPTION
|
||||
"The administration status of the CPU utilization threshold trap."
|
||||
::= { rosMgmtCpuScalarGroup 3}
|
||||
|
||||
rosMgmtCpuRisingThresholdValue OBJECT-TYPE
|
||||
SYNTAX Integer32 (2..99)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The percentage rising threshold value configured by the user.
|
||||
The value indicates, if the CPU utilization which rise from
|
||||
rosMgmtCpuFallingThresholdValue is equal to or above this value
|
||||
for rosMgmtCpuThresholdInterval duration then send
|
||||
a rosMgmtCpuRisingThreshold notification to the NMS."
|
||||
DEFVAL { 99 }
|
||||
::= { rosMgmtCpuScalarGroup 4}
|
||||
|
||||
rosMgmtCpuRecoverThresholdValue OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..98)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The percentage falling threshold value configured by the user.
|
||||
The value indicates, if the CPU utilization which fell from
|
||||
rosMgmtCpuRecoverThresholdValue is equal to or below this value
|
||||
for rosMgmtCpuThresholdInterval duration then send
|
||||
a rosMgmtCpuFallingThreshold notification to the NMS."
|
||||
DEFVAL { 79 }
|
||||
::= { rosMgmtCpuScalarGroup 5}
|
||||
|
||||
rosMgmtCpuThresholdInterval OBJECT-TYPE
|
||||
SYNTAX Integer32 (5..36000)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This is an observation interval.
|
||||
The value of this object indicates that the CPU utilization
|
||||
should be above rosMgmtCpuRisingThresholdValue for this
|
||||
duration to send a rosMgmtCpuRisingThreshold notification
|
||||
to the NMS or below rosMgmtCpuFallingThresholdValue for
|
||||
this duration to send a rosMgmtCpuFallingThreshold."
|
||||
DEFVAL { 60 }
|
||||
::= { rosMgmtCpuScalarGroup 6}
|
||||
|
||||
rosMgmtCpuNum OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Total number of cpu."
|
||||
::= { rosMgmtCpuScalarGroup 7}
|
||||
|
||||
|
||||
|
||||
--rosMgmtCpuTableGroup
|
||||
|
||||
|
||||
rosMgmtCpuTableGroup OBJECT IDENTIFIER
|
||||
::= { rosMgmtCpuObjects 2}
|
||||
|
||||
|
||||
--rosMgmtCpuUtilizationGroup
|
||||
|
||||
|
||||
rosMgmtCpuUtilizationGroup OBJECT IDENTIFIER
|
||||
::= { rosMgmtCpuTableGroup 1 }
|
||||
|
||||
|
||||
--rosMgmtCpuUtilizationTable
|
||||
|
||||
rosMgmtCpuUtilizationTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RosMgmtCpuUtilizationEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table contains information about multi-core CPU utilization."
|
||||
::= { rosMgmtCpuUtilizationGroup 1 }
|
||||
|
||||
rosMgmtCpuUtilizationEntry OBJECT-TYPE
|
||||
SYNTAX RosMgmtCpuUtilizationEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Information about the CPU utilization."
|
||||
INDEX { rosMgmtCpuUtilizationPeriod,rosMgmtCpuUtilizationCpuIdx }
|
||||
::= { rosMgmtCpuUtilizationTable 1 }
|
||||
|
||||
RosMgmtCpuUtilizationEntry ::= SEQUENCE {
|
||||
rosMgmtCpuUtilizationPeriod INTEGER,
|
||||
rosMgmtCpuUtilizationCpuIdx Integer32,
|
||||
rosMgmtCpuUtilization Integer32
|
||||
}
|
||||
|
||||
rosMgmtCpuUtilizationPeriod OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
oneSec(1),
|
||||
fiveSec(2),
|
||||
oneMin(3),
|
||||
tenMin(4),
|
||||
twoHour(5)
|
||||
}
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Periods for computing CPU utilization."
|
||||
::= { rosMgmtCpuUtilizationEntry 1 }
|
||||
|
||||
rosMgmtCpuUtilizationCpuIdx OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..16)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The cpu core index"
|
||||
::= { rosMgmtCpuUtilizationEntry 2 }
|
||||
|
||||
|
||||
rosMgmtCpuUtilization OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "percent"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"CPU busy percentage in the last specified period."
|
||||
::= { rosMgmtCpuUtilizationEntry 3 }
|
||||
|
||||
--rosMgmtTotalCPUUtilizationTable
|
||||
|
||||
|
||||
rosMgmtTotalCPUUtilizationTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RosMgmtTotalCPUUtilizationEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table contains information about total CPU utilization."
|
||||
::= { rosMgmtCpuUtilizationGroup 2 }
|
||||
|
||||
rosMgmtTotalCPUUtilizationEntry OBJECT-TYPE
|
||||
SYNTAX RosMgmtTotalCPUUtilizationEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Description."
|
||||
INDEX { rosMgmtTotalCPUPeriod }
|
||||
::= { rosMgmtTotalCPUUtilizationTable 1 }
|
||||
|
||||
RosMgmtTotalCPUUtilizationEntry ::= SEQUENCE {
|
||||
rosMgmtTotalCPUPeriod INTEGER,
|
||||
rosMgmtTotalCPUUtilization Integer32
|
||||
}
|
||||
|
||||
rosMgmtTotalCPUPeriod OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
oneSec(1),
|
||||
fiveSec(2),
|
||||
oneMin(3),
|
||||
tenMin(4),
|
||||
twoHour(5)
|
||||
}
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Periods for computing CPU utilization."
|
||||
::= { rosMgmtTotalCPUUtilizationEntry 1 }
|
||||
|
||||
|
||||
rosMgmtTotalCPUUtilization OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..10000)
|
||||
UNITS "percent"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"CPU busy percentage in the last specified period."
|
||||
::= { rosMgmtTotalCPUUtilizationEntry 2 }
|
||||
|
||||
|
||||
|
||||
|
||||
--rosMgmtCpuHistoryTable
|
||||
|
||||
rosMgmtCpuHistoryTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RosMgmtCpuHistoryEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table contains CPU hsitory utilization records."
|
||||
::= { rosMgmtCpuUtilizationGroup 3}
|
||||
|
||||
rosMgmtCpuHistoryEntry OBJECT-TYPE
|
||||
SYNTAX RosMgmtCpuHistoryEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"CPU history utilization record."
|
||||
INDEX { rosMgmtCpuHistoryPeriod, rosMgmtCpuHistoryIndex,rosMgmtCpuHistoryCpuIdx }
|
||||
::= { rosMgmtCpuHistoryTable 1 }
|
||||
|
||||
RosMgmtCpuHistoryEntry ::= SEQUENCE {
|
||||
rosMgmtCpuHistoryPeriod INTEGER,
|
||||
rosMgmtCpuHistoryIndex Integer32,
|
||||
rosMgmtCpuHistoryCpuIdx Integer32,
|
||||
rosMgmtCpuHistoryUtil Integer32
|
||||
}
|
||||
|
||||
rosMgmtCpuHistoryPeriod OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
fiveSec(1),
|
||||
oneMin(2),
|
||||
tenMin(3),
|
||||
twoHour(4)
|
||||
}
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Periods for computing CPU history utilization, the first index of CPU history utilization table."
|
||||
::= { rosMgmtCpuHistoryEntry 1 }
|
||||
|
||||
rosMgmtCpuHistoryIndex OBJECT-TYPE
|
||||
SYNTAX Integer32 (1..60)
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Process sequence number,the second index of CPU history utilization table."
|
||||
::= { rosMgmtCpuHistoryEntry 2 }
|
||||
|
||||
rosMgmtCpuHistoryCpuIdx OBJECT-TYPE
|
||||
SYNTAX Integer32 (0..16)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The cpu core index"
|
||||
::= { rosMgmtCpuHistoryEntry 3 }
|
||||
|
||||
rosMgmtCpuHistoryUtil OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "percent"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"History record of CPU utilization in the specified period. "
|
||||
::= { rosMgmtCpuHistoryEntry 4 }
|
||||
|
||||
--rosMgmtTotalCPUHistoryTable
|
||||
|
||||
rosMgmtTotalCPUHistoryTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RosMgmtTotalCPUHistoryEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table contains CPU hsitory utilization records."
|
||||
::= { rosMgmtCpuUtilizationGroup 4}
|
||||
|
||||
rosMgmtTotalCPUHistoryEntry OBJECT-TYPE
|
||||
SYNTAX RosMgmtTotalCPUHistoryEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"CPU history utilization record."
|
||||
INDEX { rosMgmtTotalCPUHistoryPeriod, rosMgmtTotalCPUHistoryIndex }
|
||||
::= { rosMgmtTotalCPUHistoryTable 1 }
|
||||
|
||||
RosMgmtTotalCPUHistoryEntry ::= SEQUENCE {
|
||||
rosMgmtTotalCPUHistoryPeriod INTEGER,
|
||||
rosMgmtTotalCPUHistoryIndex Integer32,
|
||||
rosMgmtTotalCPUHistoryUtil Integer32
|
||||
}
|
||||
|
||||
rosMgmtTotalCPUHistoryPeriod OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
fiveSec(1),
|
||||
oneMin(2),
|
||||
tenMin(3),
|
||||
twoHour(4)
|
||||
}
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Periods for computing CPU history utilization, the first index of CPU history utilization table."
|
||||
::= { rosMgmtTotalCPUHistoryEntry 1 }
|
||||
|
||||
rosMgmtTotalCPUHistoryIndex OBJECT-TYPE
|
||||
SYNTAX Integer32 (1..60)
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Process sequence number,the second index of CPU history utilization table."
|
||||
::= { rosMgmtTotalCPUHistoryEntry 2 }
|
||||
|
||||
rosMgmtTotalCPUHistoryUtil OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "percent"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"History record of CPU utilization in the specified period. "
|
||||
::= { rosMgmtTotalCPUHistoryEntry 3 }
|
||||
|
||||
|
||||
--rosMgmtCpuProcessesGroup
|
||||
|
||||
|
||||
rosMgmtCpuProcessesGroup OBJECT IDENTIFIER
|
||||
::= { rosMgmtCpuTableGroup 2 }
|
||||
|
||||
|
||||
--rosMgmtProcessesTable
|
||||
|
||||
rosMgmtProcessesTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RosMgmtProcessesEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table contains information about processes."
|
||||
::= { rosMgmtCpuProcessesGroup 1 }
|
||||
|
||||
rosMgmtProcessesEntry OBJECT-TYPE
|
||||
SYNTAX RosMgmtProcessesEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Information about processes."
|
||||
INDEX { rosMgmtProcessIndex }
|
||||
::= { rosMgmtProcessesTable 1 }
|
||||
|
||||
RosMgmtProcessesEntry ::= SEQUENCE {
|
||||
rosMgmtProcessIndex Integer32,
|
||||
rosMgmtProcessPID Integer32,
|
||||
rosMgmtProcessName OCTET STRING,
|
||||
rosMgmtProcessRunTimeTotal CPUTimeStamp,
|
||||
rosMgmtProcessInvokedTotal Integer32,
|
||||
rosMgmtProcessTimeCreated TimeStamp,
|
||||
rosMgmtProcessCurrentPriority Integer32,
|
||||
rosMgmtProcessStatus ProcessStatus
|
||||
}
|
||||
|
||||
rosMgmtProcessIndex OBJECT-TYPE
|
||||
SYNTAX Integer32 (1..2147483647)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object index of processes table. This index is PID."
|
||||
::= { rosMgmtProcessesEntry 1 }
|
||||
|
||||
rosMgmtProcessPID OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object contains the process ID."
|
||||
::= { rosMgmtProcessesEntry 2 }
|
||||
|
||||
rosMgmtProcessName OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(1..32))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The name associated with this process."
|
||||
::= { rosMgmtProcessesEntry 3 }
|
||||
|
||||
rosMgmtProcessRunTimeTotal OBJECT-TYPE
|
||||
SYNTAX CPUTimeStamp
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The amount of time the process occupied, in microseconds."
|
||||
::= { rosMgmtProcessesEntry 4 }
|
||||
|
||||
rosMgmtProcessInvokedTotal OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The number of times since rosMgmtProcessTimeCreated
|
||||
that the process has been invoked."
|
||||
::= { rosMgmtProcessesEntry 5 }
|
||||
|
||||
rosMgmtProcessTimeCreated OBJECT-TYPE
|
||||
SYNTAX TimeStamp
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The time when the process was created.
|
||||
The process sequence number and the time
|
||||
when the process was created, uniquely identifies a process."
|
||||
::= { rosMgmtProcessesEntry 6 }
|
||||
|
||||
rosMgmtProcessCurrentPriority OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The current priority at which the process is running."
|
||||
::= { rosMgmtProcessesEntry 7 }
|
||||
|
||||
rosMgmtProcessStatus OBJECT-TYPE
|
||||
SYNTAX ProcessStatus
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The current status of the process."
|
||||
::= { rosMgmtProcessesEntry 8 }
|
||||
|
||||
|
||||
|
||||
--rosMgmtProcessStatisticsTable
|
||||
|
||||
rosMgmtProcessStatisticsTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RosMgmtProcessStatisticsEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table contains statistics information for processes.
|
||||
The first index is rosMgmtProcessIndex,
|
||||
the second index is rosMgmtProcessStatisticsPeriod"
|
||||
::= { rosMgmtCpuProcessesGroup 2 }
|
||||
|
||||
rosMgmtProcessStatisticsEntry OBJECT-TYPE
|
||||
SYNTAX RosMgmtProcessStatisticsEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Statistics information for processes."
|
||||
INDEX { rosMgmtProcessIndex, rosMgmtProcessStatisticsPeriod }
|
||||
::= { rosMgmtProcessStatisticsTable 1 }
|
||||
|
||||
RosMgmtProcessStatisticsEntry ::= SEQUENCE {
|
||||
rosMgmtProcessStatisticsPeriod INTEGER,
|
||||
rosMgmtProcessRunTime CPUTimeStamp,
|
||||
rosMgmtProcessUtilization Integer32
|
||||
}
|
||||
|
||||
rosMgmtProcessStatisticsPeriod OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
fiveSec(1),
|
||||
oneMin(2),
|
||||
tenMin(3)
|
||||
}
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Periods for process statistics,
|
||||
the second index of process statistics table."
|
||||
::= { rosMgmtProcessStatisticsEntry 1 }
|
||||
|
||||
rosMgmtProcessRunTime OBJECT-TYPE
|
||||
SYNTAX CPUTimeStamp
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Time of the process occupied in the specified period."
|
||||
::= { rosMgmtProcessStatisticsEntry 2 }
|
||||
|
||||
rosMgmtProcessUtilization OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
UNITS "percent"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This object provides a general idea of how busy
|
||||
a process caused the processor to be over a specified period."
|
||||
::= { rosMgmtProcessStatisticsEntry 3 }
|
||||
|
||||
|
||||
--rosMgmtDeadProcessesTable
|
||||
|
||||
rosMgmtDeadProcessesTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF RosMgmtDeadProcessesEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table contains dead processes information."
|
||||
::= { rosMgmtCpuProcessesGroup 3 }
|
||||
|
||||
rosMgmtDeadProcessesEntry OBJECT-TYPE
|
||||
SYNTAX RosMgmtDeadProcessesEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Dead processes information."
|
||||
INDEX { rosMgmtDeadProcessIndex }
|
||||
::= { rosMgmtDeadProcessesTable 1 }
|
||||
|
||||
RosMgmtDeadProcessesEntry ::= SEQUENCE {
|
||||
rosMgmtDeadProcessIndex Integer32 ,
|
||||
rosMgmtDeadProcessName OCTET STRING,
|
||||
rosMgmtDeadProcessPriority Integer32,
|
||||
rosMgmtDeadProcessTimeDelete TimeStamp,
|
||||
rosMgmtDeadProcessDeadTimes Integer32,
|
||||
rosMgmtDeadProcessStatus ProcessStatus
|
||||
}
|
||||
|
||||
rosMgmtDeadProcessIndex OBJECT-TYPE
|
||||
SYNTAX Integer32 (1..2147483647)
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Process sequence number,the index of dead processes table. The index is PID."
|
||||
::= { rosMgmtDeadProcessesEntry 1 }
|
||||
|
||||
rosMgmtDeadProcessName OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(1..32))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The name associated with this dead process."
|
||||
::= { rosMgmtDeadProcessesEntry 2 }
|
||||
|
||||
rosMgmtDeadProcessPriority OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The priority at which the dead process."
|
||||
::= { rosMgmtDeadProcessesEntry 3 }
|
||||
|
||||
|
||||
rosMgmtDeadProcessTimeDelete OBJECT-TYPE
|
||||
SYNTAX TimeStamp
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The time when the process was deleted."
|
||||
::= { rosMgmtDeadProcessesEntry 4}
|
||||
|
||||
rosMgmtDeadProcessDeadTimes OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Times of the process dead."
|
||||
::= { rosMgmtDeadProcessesEntry 5 }
|
||||
|
||||
rosMgmtDeadProcessStatus OBJECT-TYPE
|
||||
SYNTAX ProcessStatus
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The status of the dead process."
|
||||
::= { rosMgmtDeadProcessesEntry 6}
|
||||
|
||||
|
||||
|
||||
END
|
127
mibs/raisecom/ROSMGMT-VERSION-MIB
Normal file
127
mibs/raisecom/ROSMGMT-VERSION-MIB
Normal file
@ -0,0 +1,127 @@
|
||||
--MibName=rosMgmtVersion
|
||||
-- =======================================================================
|
||||
-- Version info
|
||||
--
|
||||
-- Version 0.1 Created 2019.09.10 by wanghaisheng
|
||||
-- This version of MIB is created just for the use of Network Management Systems
|
||||
-- display the version info of the device.
|
||||
--
|
||||
-- Copyright(c) 2002-2019 by RAISECOM TECH, Ltd.
|
||||
-- modify history
|
||||
-- 02, 20200407, wanghaisheng, add rosMgmtSoftVersion.
|
||||
-- 01, 20190915, wanghaisheng, Created.
|
||||
--
|
||||
-- =======================================================================
|
||||
|
||||
ROSMGMT-VERSION-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY, OBJECT-TYPE FROM SNMPv2-SMI
|
||||
MacAddress FROM SNMPv2-TC
|
||||
rosMgmt FROM RAISECOM-BASE-MIB
|
||||
;
|
||||
rosMgmtVersion MODULE-IDENTITY
|
||||
LAST-UPDATED "201909100000Z"
|
||||
ORGANIZATION "Raisecom Science & Technology Co., ltd"
|
||||
CONTACT-INFO "www.rosMgmt.com"
|
||||
DESCRIPTION
|
||||
"The device version info Enterprise MIB definition."
|
||||
REVISION "201909100000Z" -- 10 September 2019
|
||||
DESCRIPTION
|
||||
"RAISECOM ALARM MIB initial version."
|
||||
::= { rosMgmt 131 }
|
||||
|
||||
--rosMgmtVersionNotifications OBJECT IDENTIFIER ::= { rosMgmtVersion 0 }
|
||||
rosMgmtVersionObjects OBJECT IDENTIFIER ::= { rosMgmtVersion 1 }
|
||||
|
||||
rosMgmtVersionScalarGroup OBJECT IDENTIFIER ::= { rosMgmtVersionObjects 1 }
|
||||
|
||||
rosMgmtRosVersion OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"ros software version."
|
||||
::= { rosMgmtVersionScalarGroup 1 }
|
||||
|
||||
rosMgmtHardwareVersion OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"ros hardware version."
|
||||
::= { rosMgmtVersionScalarGroup 2 }
|
||||
|
||||
rosMgmtBootstrapVersion OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"ros bootstrap version."
|
||||
::= { rosMgmtVersionScalarGroup 3 }
|
||||
|
||||
rosMgmtSerialNumber OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The serial number of the motherboard."
|
||||
::= { rosMgmtVersionScalarGroup 4 }
|
||||
|
||||
rosMgmtFpgaVersion OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"ros fpga version."
|
||||
::= { rosMgmtVersionScalarGroup 5 }
|
||||
|
||||
rosMgmtProductVersion OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"product version"
|
||||
::= { rosMgmtVersionScalarGroup 6 }
|
||||
|
||||
rosMgmtCmpAbName OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"manufacturer abbreviated name"
|
||||
::= { rosMgmtVersionScalarGroup 7 }
|
||||
|
||||
rosMgmtCmpFullName OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"manufacturer full name"
|
||||
::= { rosMgmtVersionScalarGroup 8 }
|
||||
|
||||
rosMgmtDeviceName OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"device name"
|
||||
::= { rosMgmtVersionScalarGroup 9 }
|
||||
|
||||
rosMgmtMacAddress OBJECT-TYPE
|
||||
SYNTAX MacAddress
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"MAC address."
|
||||
::= { rosMgmtVersionScalarGroup 10}
|
||||
|
||||
rosMgmtSoftVersion OBJECT-TYPE
|
||||
SYNTAX OCTET STRING
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Software version of the devcie."
|
||||
::= { rosMgmtVersionScalarGroup 11}
|
||||
|
||||
END
|
4093
tests/data/raisecom-ros.json
Normal file
4093
tests/data/raisecom-ros.json
Normal file
File diff suppressed because it is too large
Load Diff
504
tests/snmpsim/raisecom-ros.snmprec
Normal file
504
tests/snmpsim/raisecom-ros.snmprec
Normal file
@ -0,0 +1,504 @@
|
||||
1.0.8802.1.1.2.1.3.7.1.3.272637955|4x|74656E6769676162697465746865726E0a363520373420333120324620333120324620333120303020
|
||||
1.0.8802.1.1.2.1.3.7.1.3.272637959|4x|74656E6769676162697465746865726E0a363520373420333120324620333120324620333220303020
|
||||
1.0.8802.1.1.2.1.3.7.1.3.272637963|4x|74656E6769676162697465746865726E0a363520373420333120324620333120324620333320303020
|
||||
1.0.8802.1.1.2.1.3.7.1.3.272637967|4x|74656E6769676162697465746865726E0a363520373420333120324620333120324620333420303020
|
||||
1.0.8802.1.1.2.1.3.7.1.3.272646147|4x|6769676165746865726E6574312F322F0a333120303020
|
||||
1.0.8802.1.1.2.1.3.7.1.3.272646151|4x|6769676165746865726E6574312F322F0a333220303020
|
||||
1.0.8802.1.1.2.1.3.7.1.3.272646155|4x|6769676165746865726E6574312F322F0a333320303020
|
||||
1.0.8802.1.1.2.1.3.7.1.3.272646159|4x|6769676165746865726E6574312F322F0a333420303020
|
||||
1.0.8802.1.1.2.1.3.7.1.3.272646163|4x|6769676165746865726E6574312F322F0a333520303020
|
||||
1.0.8802.1.1.2.1.3.7.1.3.272646167|4x|6769676165746865726E6574312F322F0a333620303020
|
||||
1.0.8802.1.1.2.1.3.7.1.3.272646171|4x|6769676165746865726E6574312F322F0a333720303020
|
||||
1.0.8802.1.1.2.1.3.7.1.3.272646175|4x|6769676165746865726E6574312F322F0a333820303020
|
||||
1.0.8802.1.1.2.1.3.7.1.3.272646179|4x|6769676165746865726E6574312F322F0a333920303020
|
||||
1.0.8802.1.1.2.1.3.7.1.3.272646183|4x|6769676165746865726E6574312F322F0a333120333020303020
|
||||
1.0.8802.1.1.2.1.3.7.1.3.272646187|4x|6769676165746865726E6574312F322F0a333120333120303020
|
||||
1.0.8802.1.1.2.1.3.7.1.3.272646191|4x|6769676165746865726E6574312F322F0a3331203332203030
|
||||
1.0.8802.1.1.2.1.4.1.1.4.0.272637955.1|2|4
|
||||
1.0.8802.1.1.2.1.4.1.1.4.0.272637959.1|2|4
|
||||
1.0.8802.1.1.2.1.4.1.1.5.0.272637955.1|4x|F8130852E465
|
||||
1.0.8802.1.1.2.1.4.1.1.5.0.272637959.1|4x|F813084BC465
|
||||
1.0.8802.1.1.2.1.4.1.1.6.0.272637955.1|2|7
|
||||
1.0.8802.1.1.2.1.4.1.1.6.0.272637959.1|2|7
|
||||
1.0.8802.1.1.2.1.4.1.1.7.0.272637955.1|4|1292566538
|
||||
1.0.8802.1.1.2.1.4.1.1.7.0.272637959.1|4|1292566538
|
||||
1.0.8802.1.1.2.1.4.1.1.8.0.272637955.1|4|1/6/10, 1-Gig/10-Gig Ethernet, \to_goe-lab-rax-a\
|
||||
1.0.8802.1.1.2.1.4.1.1.8.0.272637959.1|4|1/6/10, 1-Gig/10-Gig Ethernet, \to_goe-lab-rax-a:TGE1/1/2\
|
||||
1.0.8802.1.1.2.1.4.1.1.9.0.272637955.1|4|goe-0-service-rt-a
|
||||
1.0.8802.1.1.2.1.4.1.1.9.0.272637959.1|4|goe-0-service-rt-b
|
||||
1.0.8802.1.1.2.1.4.1.1.10.0.272637955.1|4x|54694d4f532d422d32302e322e523120626f74682f686f70733634204e6f6b696120373235302049585220436f707972696768742028632920323030302d32303230204e6f6b69612e0a416c6c207269676874732072657365727665642e20416c6c20757365207375626a65637420746f206170706c696361626c65206c6963656e73652061677265656d656e74732e0d0a4275696c74206f6e20536174204665622032392031303a33393a3332205053542032303230206279206275696c64657220696e202f6275696c64732f632f323032422f52312f70616e6f732f6d61696e2f73726f730d
|
||||
1.0.8802.1.1.2.1.4.1.1.10.0.272637959.1|4x|54694d4f532d422d32302e322e523120626f74682f686f70733634204e6f6b696120373235302049585220436f707972696768742028632920323030302d32303230204e6f6b69612e0a416c6c207269676874732072657365727665642e20416c6c20757365207375626a65637420746f206170706c696361626c65206c6963656e73652061677265656d656e74732e0d0a4275696c74206f6e20536174204665622032392031303a33393a3332205053542032303230206279206275696c64657220696e202f6275696c64732f632f323032422f52312f70616e6f732f6d61696e2f73726f730d
|
||||
1.0.8802.1.1.2.1.4.1.1.11.0.272637955.1|4|00
|
||||
1.0.8802.1.1.2.1.4.1.1.11.0.272637959.1|4|00
|
||||
1.0.8802.1.1.2.1.4.1.1.12.0.272637955.1|4|00
|
||||
1.0.8802.1.1.2.1.4.1.1.12.0.272637959.1|4|00
|
||||
1.0.8802.1.1.2.1.4.2.1.3.0.272637955.1.1.10.49.55.50.46.49.55.46.48.46.56|2|2
|
||||
1.0.8802.1.1.2.1.4.2.1.3.0.272637959.1.1.10.49.55.50.46.49.55.46.48.46.57|2|2
|
||||
1.3.6.1.2.1.1.1.0|4|ROS_.RAX711-C-R.2020614.(null)
|
||||
1.3.6.1.2.1.1.2.0|6|1.3.6.1.4.1.8886.23.191
|
||||
1.3.6.1.2.1.1.3.0|67|62100100
|
||||
1.3.6.1.2.1.1.4.0|4|<private>
|
||||
1.3.6.1.2.1.1.5.0|4|<private>
|
||||
1.3.6.1.2.1.1.6.0|4|<private>
|
||||
1.3.6.1.2.1.2.2.1.2.268435456|4|fastethernet1/0/1
|
||||
1.3.6.1.2.1.2.2.1.2.272637955|4|tengigabitethernet1/1/1
|
||||
1.3.6.1.2.1.2.2.1.2.272637959|4|tengigabitethernet1/1/2
|
||||
1.3.6.1.2.1.2.2.1.2.272637963|4|tengigabitethernet1/1/3
|
||||
1.3.6.1.2.1.2.2.1.2.272637967|4|tengigabitethernet1/1/4
|
||||
1.3.6.1.2.1.2.2.1.2.272646147|4|gigaethernet1/2/1
|
||||
1.3.6.1.2.1.2.2.1.2.272646151|4|gigaethernet1/2/2
|
||||
1.3.6.1.2.1.2.2.1.2.272646155|4|gigaethernet1/2/3
|
||||
1.3.6.1.2.1.2.2.1.2.272646159|4|gigaethernet1/2/4
|
||||
1.3.6.1.2.1.2.2.1.2.272646163|4|gigaethernet1/2/5
|
||||
1.3.6.1.2.1.2.2.1.2.272646167|4|gigaethernet1/2/6
|
||||
1.3.6.1.2.1.2.2.1.2.272646171|4|gigaethernet1/2/7
|
||||
1.3.6.1.2.1.2.2.1.2.272646175|4|gigaethernet1/2/8
|
||||
1.3.6.1.2.1.2.2.1.2.272646179|4|gigaethernet1/2/9
|
||||
1.3.6.1.2.1.2.2.1.2.272646183|4|gigaethernet1/2/10
|
||||
1.3.6.1.2.1.2.2.1.2.272646187|4|gigaethernet1/2/11
|
||||
1.3.6.1.2.1.2.2.1.2.272646191|4|gigaethernet1/2/12
|
||||
1.3.6.1.2.1.2.2.1.3.268435456|2|6
|
||||
1.3.6.1.2.1.2.2.1.3.272637955|2|6
|
||||
1.3.6.1.2.1.2.2.1.3.272637959|2|6
|
||||
1.3.6.1.2.1.2.2.1.3.272637963|2|6
|
||||
1.3.6.1.2.1.2.2.1.3.272637967|2|6
|
||||
1.3.6.1.2.1.2.2.1.3.272646147|2|6
|
||||
1.3.6.1.2.1.2.2.1.3.272646151|2|6
|
||||
1.3.6.1.2.1.2.2.1.3.272646155|2|6
|
||||
1.3.6.1.2.1.2.2.1.3.272646159|2|6
|
||||
1.3.6.1.2.1.2.2.1.3.272646163|2|6
|
||||
1.3.6.1.2.1.2.2.1.3.272646167|2|6
|
||||
1.3.6.1.2.1.2.2.1.3.272646171|2|6
|
||||
1.3.6.1.2.1.2.2.1.3.272646175|2|6
|
||||
1.3.6.1.2.1.2.2.1.3.272646179|2|6
|
||||
1.3.6.1.2.1.2.2.1.3.272646183|2|6
|
||||
1.3.6.1.2.1.2.2.1.3.272646187|2|6
|
||||
1.3.6.1.2.1.2.2.1.3.272646191|2|6
|
||||
1.3.6.1.2.1.2.2.1.4.268435456|2|1500
|
||||
1.3.6.1.2.1.2.2.1.4.272637955|2|9198
|
||||
1.3.6.1.2.1.2.2.1.4.272637959|2|9198
|
||||
1.3.6.1.2.1.2.2.1.5.268435456|66|0
|
||||
1.3.6.1.2.1.2.2.1.6.268435456|4x|A86D5F0B884D
|
||||
1.3.6.1.2.1.2.2.1.6.272637955|4x|A86D5F0B884E
|
||||
1.3.6.1.2.1.2.2.1.6.272637959|4x|A86D5F0B884F
|
||||
1.3.6.1.2.1.2.2.1.7.268435456|2|1
|
||||
1.3.6.1.2.1.2.2.1.7.272637955|2|1
|
||||
1.3.6.1.2.1.2.2.1.7.272637959|2|1
|
||||
1.3.6.1.2.1.2.2.1.7.272637963|2|1
|
||||
1.3.6.1.2.1.2.2.1.7.272637967|2|1
|
||||
1.3.6.1.2.1.2.2.1.7.272646147|2|1
|
||||
1.3.6.1.2.1.2.2.1.7.272646151|2|1
|
||||
1.3.6.1.2.1.2.2.1.7.272646155|2|1
|
||||
1.3.6.1.2.1.2.2.1.7.272646159|2|1
|
||||
1.3.6.1.2.1.2.2.1.7.272646163|2|1
|
||||
1.3.6.1.2.1.2.2.1.7.272646167|2|1
|
||||
1.3.6.1.2.1.2.2.1.7.272646171|2|1
|
||||
1.3.6.1.2.1.2.2.1.7.272646175|2|1
|
||||
1.3.6.1.2.1.2.2.1.7.272646179|2|1
|
||||
1.3.6.1.2.1.2.2.1.7.272646183|2|1
|
||||
1.3.6.1.2.1.2.2.1.7.272646187|2|1
|
||||
1.3.6.1.2.1.2.2.1.7.272646191|2|1
|
||||
1.3.6.1.2.1.2.2.1.8.268435456|2|1
|
||||
1.3.6.1.2.1.2.2.1.8.272637955|2|1
|
||||
1.3.6.1.2.1.2.2.1.8.272637959|2|1
|
||||
1.3.6.1.2.1.2.2.1.8.272637963|2|2
|
||||
1.3.6.1.2.1.2.2.1.8.272637967|2|2
|
||||
1.3.6.1.2.1.2.2.1.8.272646147|2|2
|
||||
1.3.6.1.2.1.2.2.1.8.272646151|2|2
|
||||
1.3.6.1.2.1.2.2.1.8.272646155|2|2
|
||||
1.3.6.1.2.1.2.2.1.8.272646159|2|2
|
||||
1.3.6.1.2.1.2.2.1.8.272646163|2|2
|
||||
1.3.6.1.2.1.2.2.1.8.272646167|2|2
|
||||
1.3.6.1.2.1.2.2.1.8.272646171|2|2
|
||||
1.3.6.1.2.1.2.2.1.8.272646175|2|2
|
||||
1.3.6.1.2.1.2.2.1.8.272646179|2|2
|
||||
1.3.6.1.2.1.2.2.1.8.272646183|2|2
|
||||
1.3.6.1.2.1.2.2.1.8.272646187|2|2
|
||||
1.3.6.1.2.1.2.2.1.8.272646191|2|2
|
||||
1.3.6.1.2.1.2.2.1.9.268435456|67|5776
|
||||
1.3.6.1.2.1.2.2.1.9.272637955|67|5781
|
||||
1.3.6.1.2.1.2.2.1.9.272637959|67|5783
|
||||
1.3.6.1.2.1.2.2.1.10.268435456|65|0
|
||||
1.3.6.1.2.1.2.2.1.11.268435456|65|0
|
||||
1.3.6.1.2.1.2.2.1.12.268435456|65|0
|
||||
1.3.6.1.2.1.2.2.1.12.272637955|65|278974
|
||||
1.3.6.1.2.1.2.2.1.12.272637959|65|278961
|
||||
1.3.6.1.2.1.2.2.1.13.268435456|65|0
|
||||
1.3.6.1.2.1.2.2.1.13.272637955|65|1781
|
||||
1.3.6.1.2.1.2.2.1.13.272637959|65|17
|
||||
1.3.6.1.2.1.2.2.1.14.268435456|65|0
|
||||
1.3.6.1.2.1.2.2.1.14.272637955|65|0
|
||||
1.3.6.1.2.1.2.2.1.14.272637959|65|0
|
||||
1.3.6.1.2.1.2.2.1.15.268435456|65|0
|
||||
1.3.6.1.2.1.2.2.1.16.268435456|65|0
|
||||
1.3.6.1.2.1.2.2.1.17.268435456|65|0
|
||||
1.3.6.1.2.1.2.2.1.18.268435456|65|0
|
||||
1.3.6.1.2.1.2.2.1.18.272637955|65|1397318
|
||||
1.3.6.1.2.1.2.2.1.18.272637959|65|1383326
|
||||
1.3.6.1.2.1.2.2.1.19.268435456|65|0
|
||||
1.3.6.1.2.1.2.2.1.19.272637955|65|0
|
||||
1.3.6.1.2.1.2.2.1.19.272637959|65|0
|
||||
1.3.6.1.2.1.2.2.1.20.268435456|65|0
|
||||
1.3.6.1.2.1.2.2.1.20.272637955|65|0
|
||||
1.3.6.1.2.1.2.2.1.20.272637959|65|0
|
||||
1.3.6.1.2.1.4.22.1.1.0.1.2.1.10|2|0
|
||||
1.3.6.1.2.1.4.22.1.2.0.1.2.1.10|4x|004268352DC1
|
||||
1.3.6.1.2.1.4.22.1.2.0.78.2.1.10|4x|A86D5F009AD0
|
||||
1.3.6.1.2.1.4.22.1.2.0.120.2.1.10|4x|F48E38C6FE18
|
||||
1.3.6.1.2.1.4.39.1.2.134217728|2|2
|
||||
1.3.6.1.2.1.10.166.3.2.1.0|66|49375
|
||||
1.3.6.1.2.1.11.1.0|65|134026
|
||||
1.3.6.1.2.1.11.2.0|65|134254
|
||||
1.3.6.1.2.1.11.3.0|65|0
|
||||
1.3.6.1.2.1.11.4.0|65|12
|
||||
1.3.6.1.2.1.11.5.0|65|0
|
||||
1.3.6.1.2.1.11.6.0|65|0
|
||||
1.3.6.1.2.1.11.8.0|65|0
|
||||
1.3.6.1.2.1.11.9.0|65|0
|
||||
1.3.6.1.2.1.11.10.0|65|0
|
||||
1.3.6.1.2.1.11.11.0|65|0
|
||||
1.3.6.1.2.1.11.12.0|65|0
|
||||
1.3.6.1.2.1.11.13.0|65|792728
|
||||
1.3.6.1.2.1.11.14.0|65|0
|
||||
1.3.6.1.2.1.11.15.0|65|85967
|
||||
1.3.6.1.2.1.11.16.0|65|11644
|
||||
1.3.6.1.2.1.11.17.0|65|0
|
||||
1.3.6.1.2.1.11.18.0|65|0
|
||||
1.3.6.1.2.1.11.19.0|65|0
|
||||
1.3.6.1.2.1.11.20.0|65|0
|
||||
1.3.6.1.2.1.11.21.0|65|0
|
||||
1.3.6.1.2.1.11.22.0|65|0
|
||||
1.3.6.1.2.1.11.24.0|65|0
|
||||
1.3.6.1.2.1.11.25.0|65|0
|
||||
1.3.6.1.2.1.11.26.0|65|0
|
||||
1.3.6.1.2.1.11.27.0|65|0
|
||||
1.3.6.1.2.1.11.28.0|65|134014
|
||||
1.3.6.1.2.1.11.29.0|65|0
|
||||
1.3.6.1.2.1.11.30.0|2|1
|
||||
1.3.6.1.2.1.11.31.0|65|0
|
||||
1.3.6.1.2.1.11.32.0|65|0
|
||||
1.3.6.1.2.1.16.1.1.1.1.272637955|2|272637955
|
||||
1.3.6.1.2.1.17.7.1.1.1.0|2|1
|
||||
1.3.6.1.2.1.17.7.1.4.2.1.4.0.4095|4x|0100000002000000
|
||||
1.3.6.1.2.1.17.7.1.4.2.1.5.0.4095|4x|0100000002000000
|
||||
1.3.6.1.2.1.31.1.1.1.1.268435456|4|fastethernet1/0/1
|
||||
1.3.6.1.2.1.31.1.1.1.1.272637955|4|tengigabitethernet1/1/1
|
||||
1.3.6.1.2.1.31.1.1.1.1.272637959|4|tengigabitethernet1/1/2
|
||||
1.3.6.1.2.1.31.1.1.1.1.272637963|4|tengigabitethernet1/1/3
|
||||
1.3.6.1.2.1.31.1.1.1.1.272637967|4|tengigabitethernet1/1/4
|
||||
1.3.6.1.2.1.31.1.1.1.1.272646147|4|gigaethernet1/2/1
|
||||
1.3.6.1.2.1.31.1.1.1.1.272646151|4|gigaethernet1/2/2
|
||||
1.3.6.1.2.1.31.1.1.1.1.272646155|4|gigaethernet1/2/3
|
||||
1.3.6.1.2.1.31.1.1.1.1.272646159|4|gigaethernet1/2/4
|
||||
1.3.6.1.2.1.31.1.1.1.1.272646163|4|gigaethernet1/2/5
|
||||
1.3.6.1.2.1.31.1.1.1.1.272646167|4|gigaethernet1/2/6
|
||||
1.3.6.1.2.1.31.1.1.1.1.272646171|4|gigaethernet1/2/7
|
||||
1.3.6.1.2.1.31.1.1.1.1.272646175|4|gigaethernet1/2/8
|
||||
1.3.6.1.2.1.31.1.1.1.1.272646179|4|gigaethernet1/2/9
|
||||
1.3.6.1.2.1.31.1.1.1.1.272646183|4|gigaethernet1/2/10
|
||||
1.3.6.1.2.1.31.1.1.1.1.272646187|4|gigaethernet1/2/11
|
||||
1.3.6.1.2.1.31.1.1.1.1.272646191|4|gigaethernet1/2/12
|
||||
1.3.6.1.2.1.31.1.1.1.2.272637955|65|278968
|
||||
1.3.6.1.2.1.31.1.1.1.2.272637959|65|278956
|
||||
1.3.6.1.2.1.31.1.1.1.3.272637955|65|4
|
||||
1.3.6.1.2.1.31.1.1.1.3.272637959|65|4
|
||||
1.3.6.1.2.1.31.1.1.1.4.272637955|65|1395858
|
||||
1.3.6.1.2.1.31.1.1.1.4.272637959|65|1381895
|
||||
1.3.6.1.2.1.31.1.1.1.5.272637955|65|1459
|
||||
1.3.6.1.2.1.31.1.1.1.5.272637959|65|1431
|
||||
1.3.6.1.2.1.31.1.1.1.6.272637955|70|80691622
|
||||
1.3.6.1.2.1.31.1.1.1.6.272637959|70|87019979
|
||||
1.3.6.1.2.1.31.1.1.1.7.272637955|70|451598
|
||||
1.3.6.1.2.1.31.1.1.1.7.272637959|70|475165
|
||||
1.3.6.1.2.1.31.1.1.1.8.272637955|70|278968
|
||||
1.3.6.1.2.1.31.1.1.1.8.272637959|70|278956
|
||||
1.3.6.1.2.1.31.1.1.1.9.272637955|70|4
|
||||
1.3.6.1.2.1.31.1.1.1.9.272637959|70|4
|
||||
1.3.6.1.2.1.31.1.1.1.10.272637955|70|217011747
|
||||
1.3.6.1.2.1.31.1.1.1.10.272637959|70|218186999
|
||||
1.3.6.1.2.1.31.1.1.1.11.272637955|70|441485
|
||||
1.3.6.1.2.1.31.1.1.1.11.272637959|70|457611
|
||||
1.3.6.1.2.1.31.1.1.1.12.272637955|70|1395859
|
||||
1.3.6.1.2.1.31.1.1.1.12.272637959|70|1381895
|
||||
1.3.6.1.2.1.31.1.1.1.13.272637955|70|1459
|
||||
1.3.6.1.2.1.31.1.1.1.13.272637959|70|1431
|
||||
1.3.6.1.2.1.31.1.1.1.15.268435456|66|0
|
||||
1.3.6.1.2.1.31.1.1.1.15.272637955|66|10000
|
||||
1.3.6.1.2.1.31.1.1.1.15.272637959|66|10000
|
||||
1.3.6.1.2.1.31.1.1.1.15.272637963|66|0
|
||||
1.3.6.1.2.1.31.1.1.1.15.272637967|66|0
|
||||
1.3.6.1.2.1.31.1.1.1.15.272646147|66|0
|
||||
1.3.6.1.2.1.31.1.1.1.15.272646151|66|0
|
||||
1.3.6.1.2.1.31.1.1.1.15.272646155|66|0
|
||||
1.3.6.1.2.1.31.1.1.1.15.272646159|66|0
|
||||
1.3.6.1.2.1.31.1.1.1.15.272646163|66|0
|
||||
1.3.6.1.2.1.31.1.1.1.15.272646167|66|0
|
||||
1.3.6.1.2.1.31.1.1.1.15.272646171|66|0
|
||||
1.3.6.1.2.1.31.1.1.1.15.272646175|66|0
|
||||
1.3.6.1.2.1.31.1.1.1.15.272646179|66|0
|
||||
1.3.6.1.2.1.31.1.1.1.15.272646183|66|0
|
||||
1.3.6.1.2.1.31.1.1.1.15.272646187|66|0
|
||||
1.3.6.1.2.1.31.1.1.1.15.272646191|66|0
|
||||
1.3.6.1.2.1.31.1.1.1.16.272637955|2|2
|
||||
1.3.6.1.2.1.31.1.1.1.16.272637959|2|2
|
||||
1.3.6.1.2.1.31.1.1.1.17.272637955|2|2
|
||||
1.3.6.1.2.1.31.1.1.1.17.272637959|2|2
|
||||
1.3.6.1.2.1.31.1.1.1.18.268435456|4|Outband MGMT
|
||||
1.3.6.1.2.1.31.1.1.1.18.272637955|4|to_goe-0-service-rt-a:1/6/10
|
||||
1.3.6.1.2.1.31.1.1.1.18.272637959|4|to_goe-0-service-rt-b:1/6/10
|
||||
1.3.6.1.2.1.31.1.1.1.18.272637963|4|
|
||||
1.3.6.1.2.1.31.1.1.1.18.272637967|4|
|
||||
1.3.6.1.2.1.31.1.1.1.18.272646147|4|
|
||||
1.3.6.1.2.1.31.1.1.1.18.272646151|4|
|
||||
1.3.6.1.2.1.31.1.1.1.18.272646155|4|
|
||||
1.3.6.1.2.1.31.1.1.1.18.272646159|4|
|
||||
1.3.6.1.2.1.31.1.1.1.18.272646163|4|
|
||||
1.3.6.1.2.1.31.1.1.1.18.272646167|4|
|
||||
1.3.6.1.2.1.31.1.1.1.18.272646171|4|
|
||||
1.3.6.1.2.1.31.1.1.1.18.272646175|4|
|
||||
1.3.6.1.2.1.31.1.1.1.18.272646179|4|
|
||||
1.3.6.1.2.1.31.1.1.1.18.272646183|4|
|
||||
1.3.6.1.2.1.31.1.1.1.18.272646187|4|
|
||||
1.3.6.1.2.1.31.1.1.1.18.272646191|4|
|
||||
1.3.6.1.4.1.8886.1.18.2.2.1.1.2.272637955.3|2|-3316
|
||||
1.3.6.1.4.1.8886.1.18.2.2.1.1.2.272637955.4|2|-2708
|
||||
1.3.6.1.4.1.8886.1.18.2.2.1.1.2.272637959.3|2|-2975
|
||||
1.3.6.1.4.1.8886.1.18.2.2.1.1.2.272637959.4|2|-4401
|
||||
1.3.6.1.4.1.8886.60.1.1.1.2.1.1.1.2.1.0|2|0
|
||||
1.3.6.1.4.1.8886.60.1.1.1.2.1.1.1.2.2.0|2|0
|
||||
1.3.6.1.4.1.8886.60.1.1.1.2.1.1.1.2.3.0|2|0
|
||||
1.3.6.1.4.1.8886.60.1.1.1.2.1.1.1.2.4.0|2|0
|
||||
1.3.6.1.4.1.8886.60.1.1.1.2.1.1.1.2.5.0|2|0
|
||||
1.3.6.1.4.1.8886.60.1.1.1.2.1.1.1.3.1.0|2|31
|
||||
1.3.6.1.4.1.8886.60.1.1.1.2.1.1.1.3.2.0|2|25
|
||||
1.3.6.1.4.1.8886.60.1.1.1.2.1.1.1.3.3.0|2|21
|
||||
1.3.6.1.4.1.8886.60.1.1.1.2.1.1.1.3.4.0|2|18
|
||||
1.3.6.1.4.1.8886.60.1.1.1.2.1.1.1.3.5.0|2|18
|
||||
1.3.6.1.4.1.8886.60.1.3.1.1.1.0|2|1033288
|
||||
1.3.6.1.4.1.8886.60.1.3.1.1.2.0|2|513844
|
||||
1.3.6.1.4.1.8886.60.2.1.1.1.1.3.0|2|3
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.2.272637955.1|2|36125
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.2.272637955.2|2|32494
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.2.272637955.3|2|-3316
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.2.272637955.4|2|-2716
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.2.272637955.5|2|3202
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.2.272637959.1|2|35875
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.2.272637959.2|2|33026
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.2.272637959.3|2|-2967
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.2.272637959.4|2|-4425
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.2.272637959.5|2|3214
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.3.272637955.1|2|75000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.3.272637955.2|2|80000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.3.272637955.3|2|1522
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.3.272637955.4|2|1522
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.3.272637955.5|2|3600
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.3.272637959.1|2|75000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.3.272637959.2|2|80000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.3.272637959.3|2|1522
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.3.272637959.4|2|1522
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.3.272637959.5|2|3600
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.4.272637955.1|2|70000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.4.272637955.2|2|70000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.4.272637955.3|2|530
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.4.272637955.4|2|530
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.4.272637955.5|2|3500
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.4.272637959.1|2|70000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.4.272637959.2|2|70000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.4.272637959.3|2|530
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.4.272637959.4|2|530
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.4.272637959.5|2|3500
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.5.272637955.1|2|-10000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.5.272637955.2|2|0
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.5.272637955.3|2|-8996
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.5.272637955.4|2|-15986
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.5.272637955.5|2|3000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.5.272637959.1|2|-10000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.5.272637959.2|2|0
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.5.272637959.3|2|-8996
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.5.272637959.4|2|-15986
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.5.272637959.5|2|3000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.6.272637955.1|2|-5000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.6.272637955.2|2|0
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.6.272637955.3|2|-7986
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.6.272637955.4|2|-14989
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.6.272637955.5|2|3100
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.6.272637959.1|2|-5000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.6.272637959.2|2|0
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.6.272637959.3|2|-7986
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.6.272637959.4|2|-14989
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.6.272637959.5|2|3100
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.7.272637955.1|2|1
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.7.272637955.2|2|1
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.7.272637955.3|2|1
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.7.272637955.4|2|1
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.7.272637955.5|2|1
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.7.272637959.1|2|1
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.7.272637959.2|2|1
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.7.272637959.3|2|1
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.7.272637959.4|2|1
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.7.272637959.5|2|1
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.8.272637955.1|2|-1000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.8.272637955.2|2|-1000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.8.272637955.3|2|-36989
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.8.272637955.4|2|-1000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.8.272637955.5|2|-1000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.8.272637959.1|2|-1000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.8.272637959.2|2|-1000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.8.272637959.3|2|-36989
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.8.272637959.4|2|-1000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.8.272637959.5|2|-1000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.9.272637955.1|67|0
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.9.272637955.2|67|0
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.9.272637955.3|67|315900
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.9.272637955.4|67|0
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.9.272637955.5|67|0
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.9.272637959.1|67|0
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.9.272637959.2|67|0
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.9.272637959.3|67|315900
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.9.272637959.4|67|0
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.9.272637959.5|67|0
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.10.272637955.1|66|96
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.10.272637955.2|66|96
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.10.272637955.3|66|96
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.10.272637955.4|66|96
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.10.272637955.5|66|96
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.10.272637959.1|66|96
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.10.272637959.2|66|96
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.10.272637959.3|66|96
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.10.272637959.4|66|96
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.10.272637959.5|66|96
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.11.272637955.1|66|7
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.11.272637955.2|66|7
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.11.272637955.3|66|7
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.11.272637955.4|66|7
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.11.272637955.5|66|7
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.11.272637959.1|66|7
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.11.272637959.2|66|7
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.11.272637959.3|66|7
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.11.272637959.4|66|7
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.11.272637959.5|66|7
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.12.272637955.1|2|1
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.12.272637955.2|2|1
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.12.272637955.3|2|1
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.12.272637955.4|2|1
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.12.272637955.5|2|1
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.12.272637959.1|2|1
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.12.272637959.2|2|1
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.12.272637959.3|2|1
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.12.272637959.4|2|1
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.12.272637959.5|2|1
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.13.272637955.1|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.13.272637955.2|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.13.272637955.3|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.13.272637955.4|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.13.272637955.5|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.13.272637959.1|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.13.272637959.2|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.13.272637959.3|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.13.272637959.4|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.13.272637959.5|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.14.272637955.1|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.14.272637955.2|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.14.272637955.3|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.14.272637955.4|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.14.272637955.5|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.14.272637959.1|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.14.272637959.2|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.14.272637959.3|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.14.272637959.4|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.14.272637959.5|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.15.272637955.1|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.15.272637955.2|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.15.272637955.3|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.15.272637955.4|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.15.272637955.5|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.15.272637959.1|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.15.272637959.2|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.15.272637959.3|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.15.272637959.4|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.15.272637959.5|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.16.272637955.1|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.16.272637955.2|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.16.272637955.3|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.16.272637955.4|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.16.272637955.5|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.16.272637959.1|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.16.272637959.2|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.16.272637959.3|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.16.272637959.4|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.16.272637959.5|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.17.272637955.1|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.17.272637955.2|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.17.272637955.3|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.17.272637955.4|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.17.272637955.5|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.17.272637959.1|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.17.272637959.2|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.17.272637959.3|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.17.272637959.4|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.17.272637959.5|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.18.272637955.1|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.18.272637955.2|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.18.272637955.3|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.18.272637955.4|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.18.272637955.5|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.18.272637959.1|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.18.272637959.2|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.18.272637959.3|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.18.272637959.4|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.18.272637959.5|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.19.272637955.1|4x|C0BDF0FFC0BDF0FFC0BDF0FFC0BDF0FF
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.19.272637955.2|4x|C0BDF0FFC0BDF0FFC0BDF0FFC0BDF0FF
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.19.272637955.3|4x|C0BDF0FFC0BDF0FFC0BDF0FFC0BDF0FF
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.19.272637955.4|4x|C0BDF0FFC0BDF0FFC0BDF0FFC0BDF0FF
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.19.272637955.5|4x|C0BDF0FFC0BDF0FFC0BDF0FFC0BDF0FF
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.19.272637959.1|4x|C0BDF0FFC0BDF0FFC0BDF0FFC0BDF0FF
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.19.272637959.2|4x|C0BDF0FFC0BDF0FFC0BDF0FFC0BDF0FF
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.19.272637959.3|4x|C0BDF0FFC0BDF0FFC0BDF0FFC0BDF0FF
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.19.272637959.4|4x|C0BDF0FFC0BDF0FFC0BDF0FFC0BDF0FF
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.19.272637959.5|4x|C0BDF0FFC0BDF0FFC0BDF0FFC0BDF0FF
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.20.272637955.1|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.20.272637955.2|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.20.272637955.3|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.20.272637955.4|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.20.272637955.5|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.20.272637959.1|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.20.272637959.2|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.20.272637959.3|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.20.272637959.4|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.20.272637959.5|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.21.272637955.1|4x|60000000600000006000000060000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.21.272637955.2|4x|60000000600000006000000060000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.21.272637955.3|4x|60000000600000006000000060000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.21.272637955.4|4x|60000000600000006000000060000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.21.272637955.5|4x|60000000600000006000000060000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.21.272637959.1|4x|60000000600000006000000060000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.21.272637959.2|4x|60000000600000006000000060000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.21.272637959.3|4x|60000000600000006000000060000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.21.272637959.4|4x|60000000600000006000000060000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.21.272637959.5|4x|60000000600000006000000060000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.22.272637955.1|4x|07000000070000000700000007000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.22.272637955.2|4x|07000000070000000700000007000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.22.272637955.3|4x|07000000070000000700000007000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.22.272637955.4|4x|07000000070000000700000007000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.22.272637955.5|4x|07000000070000000700000007000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.22.272637959.1|4x|07000000070000000700000007000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.22.272637959.2|4x|07000000070000000700000007000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.22.272637959.3|4x|07000000070000000700000007000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.22.272637959.4|4x|07000000070000000700000007000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.22.272637959.5|4x|07000000070000000700000007000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.23.272637955.1|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.23.272637955.2|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.23.272637955.3|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.23.272637955.4|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.23.272637955.5|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.23.272637959.1|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.23.272637959.2|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.23.272637959.3|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.23.272637959.4|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.18.1.2.2.1.1.23.272637959.5|4x|00000000000000000000000000000000
|
||||
1.3.6.1.4.1.8886.60.34.1.1.7.0|2|6
|
||||
1.3.6.1.4.1.8886.60.131.1.1.1.0|4|ROS_6.2.0_20200614
|
||||
1.3.6.1.4.1.8886.60.131.1.1.4.0|4|103002031910S20907S0003G
|
||||
1.3.6.1.4.1.8886.60.131.1.1.6.0|4|RAX711-C-R P100R001C00
|
||||
1.3.6.1.6.3.10.2.1.3.0|2|947306093
|
Loading…