* Added support for IONODES video encoders
* fixed expected number instead of string value error when running tests
* removed extra colon
* added mibs_dir for ionodes
* removed IF-MIB from ionodes.yaml
https://community.librenms.org/t/modify-discovery-protocols-inc-php-to-fix-neighbours-problem-on-extreme-networks-exos-switch/7797
The bug is caused by SNMP polling switch-1 with ifIndex to DB (associate
ifIndex when adding switch), the port “1” is “1001”. Another switch-2
discover the switch-1 port “1” by LLDP is “1” (after LiberNMS get this
information). Two values are not equal (“1001” != “1”). If I change to
use ifName associate when adding device, because ifName is “1:1”, so it
can not equal to LLDP too (“1:1” != “1”).
* Added support for HikVision-DS Cameras
clean up
removed pointless file, cleaned up code
fixed failing unit tests, a bit of cleanup
WIP - will rebase
split hikvision into hikvision-nvr an hikvision-cam
* removed unneeded comment and rec file
* ovaldi UPS support
* ovaldi UPS tests
* serial + model + version inc tests
* update of the code using details from requester
* update of the code using details from requester
* update of the tests
* forgot discovery yaml ...
Windows puts line returns as \r\n, when parsing LibreNMS previously left the \r, which could cause issues
Centralize the code so we just have one place to fix.
Try to fix SMSEagle, it had the options wrong (copied from another transport)
* Added support for Ruijie Networks
* Extend discovery
Let's extend to all the products from this brand, at least until we have more detailed discovery
* New Device: ATS - Automatic Transfer Switch
* Small fixes
* Fixed test data
* More fixes, again
* Moved temp to php to retrieve limits from device
* Fixed perms again...
* Final test file. Or I hope so...
* device: Added support for APC AP9810 zone contacts
* fix: disconnected sensors been detected. And iemConfigProbesTable certainly does get used and it reference
* fix: load is VA, not to be confused with watts. This could be different per device though...
Apparent Power unit = VA
Real Power unit = Watts
And Keeping codeclimate happy
* feature: updated APC MIB
* feature: added test data for APC Smart UPS SMX750i and AP9810 with contact switches
* Removal of the unused variable
* Replace double quotes by single quotes when possible
* Adding spaces between operands of the concatenation operator
* Rewrite of code echoed to the browser
* Reuse the logic of the Device/Health page for displaying current and limit values
* New helper function to determine the unit for the different sensor classes
* Fixing wrong value for current unit
* The SNMP value ciscoEnvMonTemperatureThreshold is now stored as high limit (and no more as high warning limit)
* Updating misc/notifications.rss to make the user aware of the behavioral change
* Addition of missing </description> in the misc/notifications.rss
* Fix device list down devices that have never been polled
* Suggestion with 'Never' in case last_polled empty and down
* Improve handling of all cases
* fix doc comment
* Update documentation to reflect matching behaviour
Added a note to help users with matching patterns for Oxidized OS matching patterns.