* fixed general alarm codes
* fixed Cooling envelope zone. Warnings were shown instead of normal ok messages
* added current error code with description
updated mib with current error code
* Set correct OID for inverter alarms
* added up to date snmprec data
sorted state groups for rittal chiller
* added warning limits according to documentation and standards
* spaces
* Create pcoweb-rittal-lcp-3311_lcp-dx-3311.json
Co-authored-by: PipoCanaja <38363551+PipoCanaja@users.noreply.github.com>
* two-factor UI config and status display additions
* force test re-run
* removal of blade foreach via keyBy
* remove where clause against all()
* attempt where filtering with keyBy
* use @config and getPref in blade
* another forgotten @config changed
Co-authored-by: PipoCanaja <38363551+PipoCanaja@users.noreply.github.com>
* doc cleanup of general, install, getting started sections
* force tests re-run
Just to force tests re-run
Co-authored-by: PipoCanaja <38363551+PipoCanaja@users.noreply.github.com>
* Fixing irrelevant value for Juniper RPM percentage packetloss
Old MIB values fron generic DISMAN ping pingResultsProbeResponses and pingResultsSentProbes are
querying current probe values so if a probe is still pending, irrelevant value are taken. It results
in high percentage packetloss that not match reality.
Using the Juniper MIB values jnxPingLastTestResultProbeResponses and jnxPingLastTestResultSentProbes
seem to fix this.
At the same time we take here jnxPingLastTestResultAvgRttUs instead of jnxPingResultsRttUs which
is more accurate.
* Fixing typo in the name of Cisco MIB for Cisco SLA's polling
* Delete old comment about SNMP values : getting the all values once instead of one by one
* Adding test files for Juniper RPM last modification
* Revert "Adding test files for Juniper RPM last modification"
This reverts commit 0209b18b9d.
Reverting to keep snmprec junos_vmx already generated file
* Regenerating JSON test file and keeping snmprec file
* avoid forcing displayed name, so generate_device_link decides according to LibreNMS config
* same fix for BGP display
* other generate_device_link occurences
* more
* more
* Added support for the Rittal LCP DX Chiller connected to a Carel pCOWeb card. A custom MIB is also provided.
* removed .mib extension from CAREL-RITTAL-LCP-3311-MIB
* Added snmp test data
* Add TP-Link's DDM and PoE MIBs via their 20210310 archive.
* Add support for DDM sensors on TP-Link Jetstream switches.
* Add support for PoE on TP-Link switches.
* Fix linting issues.
* Fix group discrepancy in test data.
* Fix multiple discrepancies in DDM test data.
* Improve `num_oid` and `index` fields for Jetstream PoE sensors.
* Test data for PoE sensor `index` change.
* Convert Jetstream sensors to YAML and refine index names.
* Added minimal support for Eaton EMP gen2 (Env. Monitorin Probe).
Probe is readable from both xups and eaton sensor mib. Many more details available in sensor mib.
* Added states for state sensors.
Added snmprec for an Eaton 9px with firmware 2.0.5 and a connected EMPg2 device.
* added an snmprec for a device with a connected emp g2, and renamed the existing snmprec so we can refer to it as a variant
* readded xupsEnvAmbientTemp sensor
* Add support for Liebert humidity setpoint and UPS powerfactor
* Option to ignore groups so they are not sent to Oxidized
* Revert "Add support for Liebert humidity setpoint and UPS powerfactor"
This reverts commit c338528aba.
* Updated docs
* Added ignore_groups option
* Added descriptions and updated translations
* Update settings.php
* Fixed typo
Co-authored-by: Tony Murray <murraytony@gmail.com>
* filter out null lat/long values from map display queries
* removed space
* and the 2nd one
Co-authored-by: PipoCanaja <38363551+PipoCanaja@users.noreply.github.com>
* return api error when device doesn't exist
Function device_by_id_cache returns a hash table, which isn't null despite the device not existing. This checks to see if the type has been populated to also determine if the device exists.
Without this, the function always returns a "valid" device, even if one doesn't exist.
* use device_id instead of type
* Firebrick: Fix an issue which led to duplication of BGP peers.
* Code style.
* Attempt to get some sanity with BGP Table 0.
* Attempt to make it so peers are not immediately added then deleted.
* Force vrfId to Null if empty.
* Another attempt at keeping the DB clean.
* Code style.
* Stop the dicovery deleting peers it just created.
* Add support for HPE Managed Power Distribution Unit - pdu2 and pdu3
* Adding test data for hpe-mapdu from HPE P/N H8B49A (pdu2) and HPE P/N
P9S18A (pdu3)
* Remove module overrides and leave it up to user. Fix snmp_max_oid
* Fixed detection of PDU3 devices, updated testing data
* Make sysDesc definitions more specific - adding only HPE part number and
whole sysdescription of tested device.
* Change sysDescr to be less specific
* Force Test Re-run
Co-authored-by: PipoCanaja <38363551+PipoCanaja@users.noreply.github.com>
* Added New-OS: Alcatel Stellar Wireless
* Addressing StyleCI remarks
* StyleCI is still unhappy with me
* Addressing scrutinizer identified minor bug with additional type check
* Add snmprec test data
* Add json test data
* Use GitLab instead of Gitlab
Only change text part, the Alert.Transport.Gitlab class left as is.
* Fix href in document
* Move section in document
The agent list in this document is sorted by alphabetical order,
"SDFS info" is the only exception.
* Remove trailing spaces in document
* Align code in document
* Fix Markdown in document
- Escape underline
- Add syntax highlight
- Add two space in the end of line to make it a newline
- Add newline before list or code section
* Update LibreNMS/Alert/Transport/Gitlab.php
Co-authored-by: Jellyfrog <Jellyfrog@users.noreply.github.com>