mirror of
https://github.com/librenms/librenms.git
synced 2024-09-21 10:28:13 +00:00
8e3fe223ef
* new row variant * syntax * syntax * DB * syntax * schema * test * allAdvaTests * Tests * Tests * Tests * missingMigration * missingMigration * Tests * Tests * Tests * Tests * tests * tests * tests * tests * tests * test * fix_Aos7 * fix snmprec arista * fix snmprec arista * fix snmprec arista * tests * merge_fix * aos7 backslash * aos7 * more * more * defaultValue * arista * typehint * tests * tests * voss * aos7 * aos7 * aos7 * testWithoutarista-mos_metamux48-c-0-16.json * tests * ciscosb * new tests with 2004 and only sensors module * adding wireless module again * adding wireless module again (cont) * airos * aos7 * arista * arista * bdcom * fortigate * fortigate * fortigate * ftos * ftos * tests on 1804 * tests once more * tests once more, cont * tests once more, cont * tests once more, cont * tests once more, cont * tests once more, cont * more * bdcom * comware * edgeosolt * enexus * arista-mos * removeAristaAgain * ies500_manual_edit * ies500_manual_edit * mni * volius * zywal * manually imported arista-mos * manually imported arista-mos * arista-mos test is triggering something ... * restoreArista * tests * tests * aristamos * ies52xxM_4206.json * revert linux_supermicro.json * revert linux_supermicro.json * benuos * fortiadc * rnx-updu
347 lines
14 KiB
JSON
347 lines
14 KiB
JSON
{
|
|
"os": {
|
|
"discovery": {
|
|
"devices": [
|
|
{
|
|
"sysName": "<private>",
|
|
"sysObjectID": ".1.3.6.1.4.1.818.32.4.43",
|
|
"sysDescr": "IMCO SNMP Agent 10.10",
|
|
"sysContact": "<private>",
|
|
"version": "2.8",
|
|
"hardware": "XXX2.8",
|
|
"features": null,
|
|
"location": "<private>",
|
|
"os": "imcopower-big",
|
|
"type": "power",
|
|
"serial": "201254517",
|
|
"icon": "imco.png"
|
|
}
|
|
]
|
|
},
|
|
"poller": "matches discovery"
|
|
},
|
|
"sensors": {
|
|
"discovery": {
|
|
"sensors": [
|
|
{
|
|
"sensor_deleted": 0,
|
|
"sensor_class": "charge",
|
|
"poller_type": "snmp",
|
|
"sensor_oid": ".1.3.6.1.4.1.2185.1.3.11.2.1.7.12.0",
|
|
"sensor_index": "imPm1BatLeg1ChargeState.0",
|
|
"sensor_type": "imcopower-big",
|
|
"sensor_descr": "Battery Charge",
|
|
"group": null,
|
|
"sensor_divisor": 1,
|
|
"sensor_multiplier": 1,
|
|
"sensor_current": 100,
|
|
"sensor_limit": null,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": null,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": 1,
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_prev": null,
|
|
"user_func": null,
|
|
"rrd_type": "GAUGE",
|
|
"state_name": null
|
|
},
|
|
{
|
|
"sensor_deleted": 0,
|
|
"sensor_class": "current",
|
|
"poller_type": "snmp",
|
|
"sensor_oid": ".1.3.6.1.4.1.2185.1.3.11.2.1.3.24.0",
|
|
"sensor_index": "imPm1Power1OutputCurrent.0",
|
|
"sensor_type": "imcopower-big",
|
|
"sensor_descr": "Power 1 Current",
|
|
"group": null,
|
|
"sensor_divisor": 10,
|
|
"sensor_multiplier": 1,
|
|
"sensor_current": 2.5,
|
|
"sensor_limit": null,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": null,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": 1,
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_prev": null,
|
|
"user_func": null,
|
|
"rrd_type": "GAUGE",
|
|
"state_name": null
|
|
},
|
|
{
|
|
"sensor_deleted": 0,
|
|
"sensor_class": "current",
|
|
"poller_type": "snmp",
|
|
"sensor_oid": ".1.3.6.1.4.1.2185.1.3.11.2.1.4.24.0",
|
|
"sensor_index": "imPm1Power2OutputCurrent.0",
|
|
"sensor_type": "imcopower-big",
|
|
"sensor_descr": "Power 2 Current",
|
|
"group": null,
|
|
"sensor_divisor": 10,
|
|
"sensor_multiplier": 1,
|
|
"sensor_current": 0,
|
|
"sensor_limit": null,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": null,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": 1,
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_prev": null,
|
|
"user_func": null,
|
|
"rrd_type": "GAUGE",
|
|
"state_name": null
|
|
},
|
|
{
|
|
"sensor_deleted": 0,
|
|
"sensor_class": "load",
|
|
"poller_type": "snmp",
|
|
"sensor_oid": ".1.3.6.1.4.1.2185.1.3.11.2.1.3.29.0",
|
|
"sensor_index": "imPm1Power1OutputLoad.0",
|
|
"sensor_type": "imcopower-big",
|
|
"sensor_descr": "Power 1 Load (VA)",
|
|
"group": null,
|
|
"sensor_divisor": 1,
|
|
"sensor_multiplier": 1,
|
|
"sensor_current": 19,
|
|
"sensor_limit": 80,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": null,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": 1,
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_prev": null,
|
|
"user_func": null,
|
|
"rrd_type": "GAUGE",
|
|
"state_name": null
|
|
},
|
|
{
|
|
"sensor_deleted": 0,
|
|
"sensor_class": "load",
|
|
"poller_type": "snmp",
|
|
"sensor_oid": ".1.3.6.1.4.1.2185.1.3.11.2.1.4.29.0",
|
|
"sensor_index": "imPm1Power2OutputLoad.0",
|
|
"sensor_type": "imcopower-big",
|
|
"sensor_descr": "Power 2 Load (VA)",
|
|
"group": null,
|
|
"sensor_divisor": 1,
|
|
"sensor_multiplier": 1,
|
|
"sensor_current": 0,
|
|
"sensor_limit": 80,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": null,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": 1,
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_prev": null,
|
|
"user_func": null,
|
|
"rrd_type": "GAUGE",
|
|
"state_name": null
|
|
},
|
|
{
|
|
"sensor_deleted": 0,
|
|
"sensor_class": "power",
|
|
"poller_type": "snmp",
|
|
"sensor_oid": ".1.3.6.1.4.1.2185.1.3.11.2.1.3.27.0",
|
|
"sensor_index": "imPm1Power1OutputPowerW.0",
|
|
"sensor_type": "imcopower-big",
|
|
"sensor_descr": "Output Power 1",
|
|
"group": null,
|
|
"sensor_divisor": 1,
|
|
"sensor_multiplier": 1,
|
|
"sensor_current": 68,
|
|
"sensor_limit": null,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": null,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": 1,
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_prev": null,
|
|
"user_func": null,
|
|
"rrd_type": "GAUGE",
|
|
"state_name": null
|
|
},
|
|
{
|
|
"sensor_deleted": 0,
|
|
"sensor_class": "power",
|
|
"poller_type": "snmp",
|
|
"sensor_oid": ".1.3.6.1.4.1.2185.1.3.11.2.1.4.27.0",
|
|
"sensor_index": "imPm1Power2OutputPowerW.0",
|
|
"sensor_type": "imcopower-big",
|
|
"sensor_descr": "Output Power 2",
|
|
"group": null,
|
|
"sensor_divisor": 1,
|
|
"sensor_multiplier": 1,
|
|
"sensor_current": 0,
|
|
"sensor_limit": null,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": null,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": 1,
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_prev": null,
|
|
"user_func": null,
|
|
"rrd_type": "GAUGE",
|
|
"state_name": null
|
|
},
|
|
{
|
|
"sensor_deleted": 0,
|
|
"sensor_class": "runtime",
|
|
"poller_type": "snmp",
|
|
"sensor_oid": ".1.3.6.1.4.1.2185.1.3.11.2.1.7.14.0",
|
|
"sensor_index": "imPm1BatLeg1Autonomytime.0",
|
|
"sensor_type": "imcopower-big",
|
|
"sensor_descr": "Runtime",
|
|
"group": null,
|
|
"sensor_divisor": 1,
|
|
"sensor_multiplier": 1,
|
|
"sensor_current": 1512,
|
|
"sensor_limit": null,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": null,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": 1,
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_prev": null,
|
|
"user_func": null,
|
|
"rrd_type": "GAUGE",
|
|
"state_name": null
|
|
},
|
|
{
|
|
"sensor_deleted": 0,
|
|
"sensor_class": "state",
|
|
"poller_type": "snmp",
|
|
"sensor_oid": ".1.3.6.1.4.1.2185.1.3.11.2.1.3.32.0",
|
|
"sensor_index": "imPM1Power1Running1.0",
|
|
"sensor_type": "imPM1Power1Running1",
|
|
"sensor_descr": "Power State",
|
|
"group": null,
|
|
"sensor_divisor": 1,
|
|
"sensor_multiplier": 1,
|
|
"sensor_current": 0,
|
|
"sensor_limit": null,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": null,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": 1,
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_prev": null,
|
|
"user_func": null,
|
|
"rrd_type": "GAUGE",
|
|
"state_name": "imPM1Power1Running1"
|
|
},
|
|
{
|
|
"sensor_deleted": 0,
|
|
"sensor_class": "voltage",
|
|
"poller_type": "snmp",
|
|
"sensor_oid": ".1.3.6.1.4.1.2185.1.3.11.2.1.6.2.0",
|
|
"sensor_index": "imPm1BatteryVoltage.0",
|
|
"sensor_type": "imcopower-big",
|
|
"sensor_descr": "Battery Voltage",
|
|
"group": "Battery",
|
|
"sensor_divisor": 10,
|
|
"sensor_multiplier": 1,
|
|
"sensor_current": 27.4,
|
|
"sensor_limit": 31.51,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": 23.29,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": 1,
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_prev": null,
|
|
"user_func": null,
|
|
"rrd_type": "GAUGE",
|
|
"state_name": null
|
|
},
|
|
{
|
|
"sensor_deleted": 0,
|
|
"sensor_class": "voltage",
|
|
"poller_type": "snmp",
|
|
"sensor_oid": ".1.3.6.1.4.1.2185.1.3.11.2.1.3.23.0",
|
|
"sensor_index": "imPm1Power1OutputVoltage.0",
|
|
"sensor_type": "imcopower-big",
|
|
"sensor_descr": "Power 1 Voltage",
|
|
"group": "Power",
|
|
"sensor_divisor": 10,
|
|
"sensor_multiplier": 1,
|
|
"sensor_current": 27.4,
|
|
"sensor_limit": 31.51,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": 23.29,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": 1,
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_prev": null,
|
|
"user_func": null,
|
|
"rrd_type": "GAUGE",
|
|
"state_name": null
|
|
},
|
|
{
|
|
"sensor_deleted": 0,
|
|
"sensor_class": "voltage",
|
|
"poller_type": "snmp",
|
|
"sensor_oid": ".1.3.6.1.4.1.2185.1.3.11.2.1.4.23.0",
|
|
"sensor_index": "imPm1Power2OutputVoltage.0",
|
|
"sensor_type": "imcopower-big",
|
|
"sensor_descr": "Power 2 Voltage",
|
|
"group": "Power",
|
|
"sensor_divisor": 10,
|
|
"sensor_multiplier": 1,
|
|
"sensor_current": -48.1,
|
|
"sensor_limit": -40.885,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": -55.315,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": 1,
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_prev": null,
|
|
"user_func": null,
|
|
"rrd_type": "GAUGE",
|
|
"state_name": null
|
|
}
|
|
],
|
|
"state_indexes": [
|
|
{
|
|
"state_name": "imPM1Power1Running1",
|
|
"state_descr": "Online",
|
|
"state_draw_graph": 0,
|
|
"state_value": 0,
|
|
"state_generic_value": 0
|
|
},
|
|
{
|
|
"state_name": "imPM1Power1Running1",
|
|
"state_descr": "Battery",
|
|
"state_draw_graph": 0,
|
|
"state_value": 1,
|
|
"state_generic_value": 2
|
|
}
|
|
]
|
|
},
|
|
"poller": "matches discovery"
|
|
}
|
|
}
|