ENTERASYS-ESWITCH-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,
Unsigned32 FROM SNMPv2-SMI
TruthValue, TEXTUAL-CONVENTION FROM SNMPv2-TC
MODULE-COMPLIANCE,
OBJECT-GROUP FROM SNMPv2-CONF
EnabledStatus FROM P-BRIDGE-MIB
PortList FROM Q-BRIDGE-MIB
ifIndex FROM IF-MIB
etsysModules FROM ENTERASYS-MIB-NAMES;
enterasysESwitchMIB MODULE-IDENTITY
LAST-UPDATED "200203071950Z" -- Thu Mar 7 19:50 GMT 2002
ORGANIZATION "Enterasys Networks, Inc"
CONTACT-INFO
"Postal: Enterasys Networks
35 Industrial Way, P.O. Box 5005
Rochester, NH 03867-0505
Phone: +1-603-332-9400
E-Mail: support@enterasys.com
WWW: http://www.enterasys.com"
DESCRIPTION
"The Enterasys Networks Proprietary MIB module for
entities implementing the Extended Switch Objects."
REVISION "200203071950Z" -- Thu Mar 7 19:50 GMT 2002
DESCRIPTION
"Imported etsysModules from the correct MIB."
REVISION "200102131100Z"
DESCRIPTION
"The initial version of this MIB module."
::= { etsysModules 10 }
-- ----------------------------------------------------------------------------
-- Textual Conventions (i.e., these do not affect object encoding):
-- ----------------------------------------------------------------------------
--
-- "DURABLE":
-- Objects that are saved across a system reset and/or power cycle
-- are noted as "DURABLE" for convenience in the DESCRIPTION
-- section of the object definition. Code must be explicitly
-- written to implement these DURABLE objects.
--
-- "PERSISTENT":
-- This keyword is used to define persistent NVM+ objects (i.e.,
-- object values that survive a system "reset to factory
-- defaults").
--
-- ----------------------------------------------------------------------------
-- Enterasys Extended Switch MIB-OIDs for Access Point.
-- ----------------------------------------------------------------------------
etsysESwitchObjects OBJECT IDENTIFIER ::= { enterasysESwitchMIB 1 }
-- ****************************************************************************
etsysESwitchParams OBJECT IDENTIFIER ::= { etsysESwitchObjects 1 }
etsysESwitchRateLimiting OBJECT IDENTIFIER ::= { etsysESwitchObjects 2 }
etsysESwitchFilter OBJECT IDENTIFIER ::= { etsysESwitchObjects 3 }
etsysESwitchProtocolObjects OBJECT IDENTIFIER ::= { etsysESwitchObjects 4 }
-- ****************************************************************************
--
-- etsysESwitchParams - The Extended system module
-- This group consists of objects that detremine the state of
-- the Access Piont.
--
etsysESwitchAdminStatus OBJECT-TYPE
SYNTAX EnabledStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DURABLE:
The meanings of the values are:
enabled(1) - setting this object to enabled causes the
device to begin it's power up sequence and attempt to
enter its operational state. If the value of this object
was disabled, then the non-volatile value of this object
is changed to enabled. As part of the power up sequence,
the device's management parameters may or may not be
reset. (In other words, the device may go through the
equivalent of a reset or before returning to the online state.
If the device is capable of going directly from the disabled
state to the enabled state without resetting any of its
management parameters, then it may do so. Such action is
product specific.)
disabled(2) - setting this object to offline causes the
device to cease network activity and enter a quiescent
state. A disabled device must still be able to respond
to management messages.
The value enable(1) or disable(2) shall be stored
in non-volatile memory for the initial reset value
of this variable. The factory default NV value is enable(1)."
::= { etsysESwitchParams 1 }
-- ****************************************************************************
etsysESwitchRateLimitingTable OBJECT-TYPE
SYNTAX SEQUENCE OF EtsysESwitchRateLimitingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table allows rate limiting of multicast frames
received on bridge ports. A typical application of this
might be to limit a broadcast storm to the confines
of the LAN connected by the bridge.
All objects in this table must be saved across a system
reset and/or a power cycle."
::= { etsysESwitchRateLimiting 1 }
etsysESwitchRateLimitingEntry OBJECT-TYPE
SYNTAX EtsysESwitchRateLimitingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An Entry (conceptual row) in the RateLimiting Table.
A collection of objects containing information for
enabling and configuring RateLimiting."
INDEX {ifIndex}
::= { etsysESwitchRateLimitingTable 1 }
EtsysESwitchRateLimitingEntry ::=
SEQUENCE {
etsysESwitchRateLimitSwitch TruthValue,
etsysESwitchRateLimit Unsigned32
}
etsysESwitchRateLimitSwitch OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DURABLE:
By default, rate limiting will be disabled. It can be
enabled by setting this object to 'true(1)'."
::= { etsysESwitchRateLimitingEntry 1 }
etsysESwitchRateLimit OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DURABLE:
This is the maximum number of rate-limited frames per second
that the bridge will forward per second."
::= { etsysESwitchRateLimitingEntry 2 }
-- ***********************************************************************
--
-- etsysESwitchFilter - The Extended Switch Filter group
-- These are bridge objects implemented in Enterasys Extended Switch
-- over and above what is required by the Standard Bridge MIBs
--
-- etsysESwitchFilter - per-port address filtering switches
-- for multiport switch
etsysESwitchAddrFilterTable OBJECT-TYPE
SYNTAX SEQUENCE OF EtsysESwitchAddrFilterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of interface entries. The number of entries is
given by ifNumber, defined in MIB-II."
::= { etsysESwitchFilter 1 }
etsysESwitchAddrFilterEntry OBJECT-TYPE
SYNTAX EtsysESwitchAddrFilterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A collection of objects containing information for a
given interface."
INDEX { ifIndex }
::= { etsysESwitchAddrFilterTable 1 }
EtsysESwitchAddrFilterEntry ::=
SEQUENCE {
etsysESwitchAddressFilter TruthValue
}
etsysESwitchAddressFilter OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DURABLE:
A switch that controls address filtering. When true,
the bridge purges the learned entries from its forwarding
database, stops its learning process, and forwards only
frames with destination and source addresses that have
been specified via management."
::= { etsysESwitchAddrFilterEntry 1 }
-- ***********************************************************************
-- -------------------------------------------------------------------------
-- User-defined EtherType table
-- -------------------------------------------------------------------------
etsysESwitchEtherTypeTable OBJECT-TYPE
SYNTAX SEQUENCE OF EtsysESwitchEtherTypeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table for defining the meaning of the 'userEtherType' rows in the
etsysESwitchProtocolTable."
::= { etsysESwitchProtocolObjects 1 }
etsysESwitchEtherTypeEntry OBJECT-TYPE
SYNTAX EtsysESwitchEtherTypeEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each row defines a particular EtherType that may be used as a basis
for protocol filtering and VLAN classification."
INDEX {
etsysESwitchEtherTypeIndex
}
::= { etsysESwitchEtherTypeTable 1 }
EtsysESwitchEtherTypeEntry ::=
SEQUENCE {
etsysESwitchEtherTypeIndex
INTEGER,
etsysESwitchEtherTypeValue
OCTET STRING,
etsysESwitchEtherTypeStatus
INTEGER,
etsysESwitchEtherTypePreempted
TruthValue
}
etsysESwitchEtherTypeIndex OBJECT-TYPE
SYNTAX INTEGER( 1..1000 )
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and N that identifies a table row, and that serves
to link entries in this table to those in etsysESwitchProtocolTable."
::= { etsysESwitchEtherTypeEntry 1 }
etsysESwitchEtherTypeValue OBJECT-TYPE
SYNTAX OCTET STRING( SIZE(2) )
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Defines an EtherType for use with etsysESwitchESwitchProtocolTable."
::= { etsysESwitchEtherTypeEntry 2 }
etsysESwitchEtherTypeStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
invalid(2),
permanent(3),
deleteOnReset(4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the administrative status of this entry.
other(1) - This entry is currently in effect, but the conditions
under which it will remain so differ from the ones described
for the other enumeration values
invalid(2) - Writing this value invalidates the entry. The agent
may (but is not required to) delete the row.
permanent(3) - This entry is currently in use and will remain so
after the next reset of the bridge.
deleteOnReset(4) - This entry is currently in use and will remain
so until the next reset of the bridge."
DEFVAL { permanent }
::= { etsysESwitchEtherTypeEntry 3 }
etsysESwitchEtherTypePreempted OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If true, indicates that the switch has taken control of this row and
its associated resources (e.g., to support 802.1x authentication)."
::= { etsysESwitchEtherTypeEntry 4 }
-- -------------------------------------------------------------------------
-- Protocol-based filtering/VLAN table
-- -------------------------------------------------------------------------
etsysESwitchProtocolTable OBJECT-TYPE
SYNTAX SEQUENCE OF EtsysESwitchProtocolEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table for configuring, and obtaining information about, protocol-
based filtering and VLAN assignment."
::= { etsysESwitchProtocolObjects 2 }
etsysESwitchProtocolEntry OBJECT-TYPE
SYNTAX EtsysESwitchProtocolEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each row in etsysESwitchProtocolTable holds filtering instructions,
or VLAN classification instructions, for one (port, protocol) pair."
INDEX {
etsysESwitchProtocolReceivePort,
etsysESwitchProtocolType,
etsysESwitchProtocolIndex
}
::= { etsysESwitchProtocolTable 1 }
EtsysESwitchProtocolEntry ::=
SEQUENCE {
etsysESwitchProtocolReceivePort
INTEGER,
etsysESwitchProtocolType
INTEGER,
etsysESwitchProtocolIndex
INTEGER,
etsysESwitchProtocolConstraint
INTEGER,
etsysESwitchProtocolAllowedToGoTo
PortList,
etsysESwitchProtocolVlanId
INTEGER,
etsysESwitchProtocolStatus
INTEGER,
etsysESwitchProtocolPreempted
TruthValue
}
etsysESwitchProtocolReceivePort OBJECT-TYPE
SYNTAX INTEGER ( 0..2147483647 )
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Identifies the receive port to which the protocol filter is to be
applied. The value '0' (when allowed) represents 'all ports'."
::= { etsysESwitchProtocolEntry 1 }
etsysESwitchProtocolType OBJECT-TYPE
SYNTAX INTEGER {
userEtherType(1),
ipv4(2),
ipxEthernet(3),
ipxRaw(4),
ipxLlc(5),
ipxSnap(6),
sna(7),
netBios(8),
decnet(9),
ipv6(10)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Identifies the protocol type. The switch chip in the RoamAbout M2
can recognize nine predefined high-level protocol types, and up to
three user-defined EtherTypes. (Some or all EtherType filters may
be reserved for use in implementing other features.)
Protocol types are as follows:
userEtherType(1) - Packets whose Ethernet V2 EtherTypes or IEEE
802.3 LLC/SNAP EtherTypes match the user-defined EtherType
etsysESwitchEtherType[ etsysESwitchProtocolIndex ].
ipv4(2) - Internet Protocol version 4 carried in Ethernet V2
frames or IEEE 802.3 frames with LLC/SNAP headers. Also,
ARP packets carried in Ethernet V2 frames.
ipxEthernet(3) - IPX carried in Ethernet V2 frames.
ipxRaw(4) - IPX carried in IEEE 802.3 frames with no LLC.
ipxLlc(5) - IPX carried in IEEE 802.3 frames with LLC headers.
ipxSnap(6) - IPX carried in IEEE 802.3 frames with LLC/SNAP
headers.
sna(7) - SNA carried in IEEE 802.3 frames with LLC headers.
netBios(8) - NetBIOS carried in IEEE 802.3 frames with LLC
headers.
decnet(9) - DECnet carried in Ethernet V2 frames or in IEEE 802.3
frames with LLC/SNAP headers.
ipv6(10) - Internet Protocol version 6 carried in Ethernet V2
frames or IEEE 802.3 frames with LLC/SNAP headers"
::= { etsysESwitchProtocolEntry 2 }
etsysESwitchProtocolIndex OBJECT-TYPE
SYNTAX INTEGER ( 1..1000 )
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"When etsysESwitchProtocolType indicates a user-defined protocol type,
this index should identify the corresponding protocol definition.
That is, to say, for a 'userEtherType' row, this index should point
to a row in the etsysESwitchEtherTypeTable.
When etsysESwitchProtocolType completely specifies the protocol type,
this index should be set to 1."
::= { etsysESwitchProtocolEntry 3 }
etsysESwitchProtocolConstraint OBJECT-TYPE
SYNTAX INTEGER {
portMask(1),
vlan(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates what type of constraint the switch should apply to packets
caught by the (port, protocol) filter.
portMask(1) - Use the etsysESwitchProtocolAllowedToGoTo mask to
determine where the packets may be forwarded.
vlan(2) - Classify the packets as belonging to the VLAN
etsysESwitchProtocolVlanId.
Note that on the RoamAbout AccessPoint R2, port/protocol constraints
can sometimes take a back seat to other kinds of access controls."
DEFVAL { portMask }
::= { etsysESwitchProtocolEntry 4 }
etsysESwitchProtocolAllowedToGoTo OBJECT-TYPE
SYNTAX PortList
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A port mask object indicating where packets that match this row's
(port, protocol) filter are allowed to go.
It applies when etsysESwitchProtocolConstraint has the value
portMask(1) and this row is valid."
::= { etsysESwitchProtocolEntry 5 }
etsysESwitchProtocolVlanId OBJECT-TYPE
SYNTAX INTEGER ( 0..2147483647 )
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A number identifying a VLAN to which packets that match this row's
(port, protocol) filter should be assigned.
It applies when etsysESwitchProtocolConstraint has the value vlan(2)
and this row is valid."
::= { etsysESwitchProtocolEntry 6 }
etsysESwitchProtocolStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
invalid(2),
permanent(3),
deleteOnReset(4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the administrative status of this entry.
other(1) - This entry is currently in effect, but the conditions
under which it will remain so differ from the ones described
for the other enumeration values
invalid(2) - Writing this value to the object deletes the filter
or VLAN constraint. The agent may delete the SNMP table row
or return an AdminStatus of 'invalid' at its discretion.
permanent(3) - This entry is currently in use and will remain so
after the next reset of the bridge.
deleteOnReset(4) - This entry is currently in use and will remain
so until the next reset of the bridge."
DEFVAL { permanent }
::= { etsysESwitchProtocolEntry 7 }
etsysESwitchProtocolPreempted OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If true, indicates that the switch has taken control of this row and
its associated resources (e.g., to support 802.1x authentication)."
::= { etsysESwitchProtocolEntry 8 }
-- ----------------------------------------------------------------------------
-- Conformance Information
-- ----------------------------------------------------------------------------
etsysESwitchConformance OBJECT IDENTIFIER ::= { enterasysESwitchMIB 2 }
etsysESwitchGroups OBJECT IDENTIFIER ::= { etsysESwitchConformance 1 }
etsysESwitchCompliances OBJECT IDENTIFIER ::= { etsysESwitchConformance 2 }
-- ----------------------------------------------------------------------------
-- Units of conformance
-- ----------------------------------------------------------------------------
etsysESwitchBaseGroup OBJECT-GROUP
OBJECTS {
etsysESwitchAdminStatus,
etsysESwitchRateLimitSwitch,
etsysESwitchRateLimit,
etsysESwitchAddressFilter
}
STATUS current
DESCRIPTION
"The basic etsysESwitch objects."
::= { etsysESwitchGroups 1 }
etsysESwitchEtherTypeGroup OBJECT-GROUP
OBJECTS {
etsysESwitchEtherTypeValue,
etsysESwitchEtherTypeStatus,
etsysESwitchEtherTypePreempted
}
STATUS current
DESCRIPTION
"A collection of objects for configuring user-defined EtherTypes."
::= { etsysESwitchGroups 2 }
etsysESwitchProtocolGroup OBJECT-GROUP
OBJECTS {
etsysESwitchProtocolConstraint,
etsysESwitchProtocolAllowedToGoTo,
etsysESwitchProtocolVlanId,
etsysESwitchProtocolStatus,
etsysESwitchProtocolPreempted
}
STATUS current
DESCRIPTION
"A collection of objects for configuring protocol-based filtering."
::= { etsysESwitchGroups 3 }
-- ----------------------------------------------------------------------------
-- Compliance statements
-- ----------------------------------------------------------------------------
etsysESwitchCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for devices that support
Extended Switch."
MODULE ENTERASYS-ESWITCH-MIB
MANDATORY-GROUPS { etsysESwitchBaseGroup }
GROUP etsysESwitchEtherTypeGroup
DESCRIPTION
"This group is optional."
GROUP etsysESwitchProtocolGroup
DESCRIPTION
"This group is optional."
OBJECT etsysESwitchEtherTypeValue
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT etsysESwitchEtherTypeStatus
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required. An implementation does
not need to support all possible status types."
OBJECT etsysESwitchProtocolConstraint
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required. An implementation does
not need to support all possible constraint types."
OBJECT etsysESwitchProtocolAllowedToGoTo
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT etsysESwitchProtocolVlanId
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT etsysESwitchProtocolStatus
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required. An implementation does
not need to support all possible status types."
::= { etsysESwitchCompliances 1 }