CABLETRON-TRAPS DEFINITIONS ::= BEGIN
|
|
|
|
-- cabletron-traps.txt
|
|
-- Revision: 01.04.03
|
|
-- Part Number: 2170994
|
|
-- Date: January 10, 1999
|
|
|
|
-- Date "200402061530Z" - Fri Feb 6 15:30 GMT 2004
|
|
-- Added boardOperational and boardNonOperational traps.
|
|
|
|
-- "Postal: Enterasys Networks
|
|
-- 50 Minuteman Rd.
|
|
-- Andover, MA 01810-1008
|
|
-- USA
|
|
-- Phone: +1 978 684 1000
|
|
-- E-mail: support@enterasys.com
|
|
-- WWW: http://www.enterasys.com"
|
|
|
|
-- This module provides authoritative definitions for Cabletron's
|
|
-- use of IETF and enterprise-specific snmp traps.
|
|
--
|
|
-- This module will be extended, as required.
|
|
--
|
|
|
|
-- Enterasys Networks reserves the right to make changes in
|
|
-- specification and other information contained in this document
|
|
-- without prior notice. The reader should consult Enterasys Networks
|
|
-- to determine whether any such changes have been made.
|
|
--
|
|
-- In no event shall Enterasys Networks be liable for any incidental,
|
|
-- indirect, special, or consequential damages whatsoever (including
|
|
-- but not limited to lost profits) arising out of or related to this
|
|
-- document or the information contained in it, even if Enterasys
|
|
-- Networks has been advised of, known, or should have known, the
|
|
-- possibility of such damages.
|
|
--
|
|
-- Enterasys grants vendors, end-users, and other interested parties
|
|
-- a non-exclusive license to use this specification in connection
|
|
-- with the management of Enterasys products.
|
|
|
|
-- Copyright (c)1998 Cabletron Systems
|
|
-- Copyright (c)2004 Enterasys Networks
|
|
|
|
-- ---------------------
|
|
-- Top Level Definitions
|
|
-- ---------------------
|
|
|
|
-- Imports
|
|
|
|
IMPORTS
|
|
cabletron
|
|
FROM CTRON-OIDS
|
|
TRAP-TYPE
|
|
FROM RFC-1215
|
|
ifIndex
|
|
FROM RFC1213-MIB
|
|
|
|
logEventIndex, logIndex, logTime, logDescription
|
|
FROM RFC1271-MIB
|
|
|
|
lecRowStatus FROM LAN-EMULATION-CLIENT-MIB
|
|
|
|
fddimibSMTIndex, fddimibPORTIndex, fddimibMACIndex, fddimibSMTCFState,
|
|
fddimibPORTConnectState, fddimibSMTMasterCts, fddimibPORTAction,
|
|
fddimibPORTLerEstimate, fddimibMACRMTState, fddimibMACCurrentPath,
|
|
fddimibMACFrameErrorRatio
|
|
FROM FDDI-SMT73-MIB -- rfc1512
|
|
|
|
ctsmtmibRingTopology, ctsmtmibRingSmtIndex, ctsmtmibRingMacIndex,
|
|
ctsmtmibRingNodeIndex, ctsmtmibRingMacAddr
|
|
FROM CTSMTMIB-MIB
|
|
|
|
nwAppnFwdLsAdjCpName, nwAppnFwdLsAdjCpType,
|
|
nwAppnFwdLsName, nwAppnEventTextString
|
|
FROM CTRON-APPN-MIB
|
|
|
|
nwAtEventTextString
|
|
FROM CTRON-AppleTalk-ROUTER-MIB
|
|
|
|
snmpPollDestination, snmpPollOwner, snmpOIDDestination,
|
|
snmpOIDOwner, snmpOIDSequence, snmpOIDObject
|
|
FROM DLM-MIB
|
|
bdgdeviceStatus
|
|
FROM CTRON-BDG-MIB
|
|
|
|
rptrSrcAddrMgmtPortLock, rptrPortAlarmBroadThreshold,
|
|
rptrMgmtInterfaceNum, rptrAlarmsTrafThreshold,
|
|
rptrAlarmsErrThreshold, rptrAlarmsErrSource,
|
|
rptrAlarmsCollThreshold, rptrPortGrpAlarmBroadThreshold,
|
|
rptrAlarmsBroadThreshold, rptrAlarmsAlarmTimebase,
|
|
rptrPortGrpMgmtGrpId, rptrPortGrpAlarmTrafThreshold,
|
|
rptrPortGrpAlarmErrThreshold, rptrPortGrpAlarmErrSource,
|
|
rptrPortGrpAlarmCollThreshold, rptrPortSecurityLockStatus,
|
|
rptrPortMgmtPortType, rptrPortMgmtPortId,
|
|
rptrPortRedundCrctNum, rptrPortSrcAddrTopoState,
|
|
rptrPortSrcAddrAddressList, rptrPortAlarmTrafThreshold,
|
|
rptrPortAlarmErrThreshold, rptrPortAlarmErrSource,
|
|
rptrPortAlarmCollThreshold, rptrPortSecurityPortGrpId,
|
|
rptrPortSecurityPortId, rptrPortSecuritySecureState,
|
|
rptrSecurityLearnState, rptrPortGrpSrcAddrLockGrpId,
|
|
rptrPortGrpSASecurityLearnState,
|
|
rptrPortSecurityLearnState, rptrSecurityLearnMode,
|
|
rptrPortGrpSASecurityLearnMode,
|
|
rptrPortSecurityLearnMode
|
|
FROM REPEATER-REV4-MIB
|
|
|
|
chSlotID, chSlotModuleType
|
|
FROM CHASSIS-MIB
|
|
|
|
powerSupplyNum, deviceType
|
|
FROM CTRON-COMMON-MIB
|
|
|
|
ctFpRedundActivePort
|
|
FROM CTRON-FRONTPANEL-MIB
|
|
|
|
nwIpEventTextString
|
|
FROM CTRON-IP-ROUTER-MIB
|
|
|
|
nwIpxEventTextString
|
|
FROM CTRON-IPX-ROUTER-MIB
|
|
|
|
nwDecIVEventTextString
|
|
FROM CTRON-DECIV-ROUTER-MIB
|
|
|
|
|
|
ctIfNumber, ctIfPortPortNumber, ctIfPortType
|
|
FROM CTIF-EXT-MIB
|
|
|
|
psPowerSlotStatusID, boardPowerSlotStatusID, psPowerSlotID,
|
|
chPowerMainVoltageStatus, chPowerMainVoltage,
|
|
chPowerDiagVoltageStatus, chPowerDiagVoltage, termPowerStatus,
|
|
termPowerVoltage, boardPowerSlotID, boardPowerID,
|
|
boardPowerStatus, termPowerModule1Status, termPowerModule2Status,
|
|
boardPowerCurrent, boardPowerLocalAdminStatus, boardPowerLocalStatus,
|
|
boardPowerOperationalStatus, psPowerID, psPowerOperationalStatus,
|
|
psPowerAdmin, psPowerCurrent, psPowerStatus, psPowerVoltage,
|
|
boardPowerVoltage, chPowerLineMaxSupply, chPowerLineTotalSupply
|
|
FROM CTRON-POWER-SUPPLY-MIB
|
|
|
|
psEnvFanStatus, psEnvSlotID, psEnvFanSpeed, psEnvTemp,
|
|
psEnvTempStatus, chEnvFanSpeed, chEnvFanStatus, chEnvFanID,
|
|
chEnvAmbientStatus, chEnvAmbientTemp, chEnvHumidityStatus,
|
|
chEnvHumidity, boardEnvSlotID, boardEnvTemp, boardEnvTempStatus,
|
|
boardEnvTempRelStatus
|
|
FROM CTRON-ENVIRONMENT-MIB
|
|
|
|
contTypePhysicalChanges, contTypeLogicalChanges,
|
|
contPhysicalEntryID
|
|
FROM CT-CONTAINER-MIB
|
|
|
|
tRingAlarmsRingRingPurgesThreshold,
|
|
tRingStatsRingLastBeaconType,
|
|
tRingAlarmsRingTimebase,
|
|
tRingAlarmsRingAMPErrsThreshold,
|
|
tRingAlarmsRingTokenErrsThreshold,
|
|
tRingAlarmsRingClaimTknThreshold,
|
|
tRingAlarmsRingLostFramesThreshold,
|
|
tRingAlarmsRingBeaconStateThreshold,
|
|
tRingAlarmsRingFrameCountThreshold,
|
|
tRingAlarmsStnThrshLineErrsThreshold,
|
|
tRingAlarmsStnThrshInternalErrsThreshold,
|
|
tRingAlarmsStnThrshBurstErrsThreshold,
|
|
tRingAlarmsStnThrshACErrsThreshold,
|
|
tRingAlarmsStnThrshRcvrCongestThreshold,
|
|
tRingAlarmsStnThrshAddress,
|
|
tRingMgmtStnName,tRingMgmtStnBoard,
|
|
tRingMgmtStnPort,tRingMgmtStnUNA,
|
|
tRingMgmtSecurityAddressAdd,
|
|
tRingMgmtSecurityAddressRemove,
|
|
tRingStatsRingLastBeacon, tRingMgmtStnAddress,
|
|
tRingPortMgmtPortId, tRingPortGrpId,
|
|
tRingMgmtStnDNA
|
|
FROM DOT5-LOG-MIB
|
|
|
|
ctATMPhyRedundIfIndex
|
|
FROM CTATM-CONFIG-MIB
|
|
|
|
ctBroadcastDesiredBroadcastThreshold, ctBroadcastCtlSlotID,
|
|
ctBroadcastCtlInterface
|
|
FROM CT-BROADCAST-MIB
|
|
|
|
ctChasPowerSupplyNum, ctChasPowerSupplyType
|
|
FROM CTRON-CHASSIS-MIB
|
|
|
|
upsIndex, upsStatusFault, upsExtMeasAlarmStatus,
|
|
upsAddlFuncsStatusFault
|
|
FROM UPS2-MIB
|
|
|
|
atmInterfaceMyNeighborIpAddress,
|
|
atmInterfaceMyNeighborIfName,atmVpCrossConnectRowStatus,
|
|
atmVcCrossConnectRowStatus
|
|
FROM ATM-MIB
|
|
|
|
sfpsNodeTablePort,sfpsNodeTableBaseAddress
|
|
FROM CTRON-SFPS-DIRECTORY-MIB
|
|
|
|
sfpsDirViolationType, sfpsDirViolationAOValue
|
|
FROM CTRON-SFPS-TOPOLOGY-MIB
|
|
|
|
sfpsInPortConfigType, sfpsInPortConfigPort
|
|
FROM CTRON-SFPS-PORT-MIB
|
|
sfpsBlockResolveTableAOValue
|
|
FROM CTRON-SFPS-RESOLVE-MIB
|
|
sfpsBlockSourceMAC
|
|
FROM CTRON-SFPS-BASE-MIB;
|
|
|
|
-- ===================================================================
|
|
|
|
--
|
|
-- Cabletron`s Enterprise Trap Definitions
|
|
--
|
|
|
|
ctdlswTConnUp TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
DESCRIPTION
|
|
"This trap is sent each time a transport connection
|
|
becomes enabled on this DLSw."
|
|
::= 1
|
|
|
|
ctdlswTConnDown TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
DESCRIPTION
|
|
"This trap is sent each time a transport connection
|
|
becomes disabled on this DLSw."
|
|
::= 2
|
|
|
|
|
|
portSegmenting TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { rptrPortGrpMgmtGrpId,
|
|
rptrPortMgmtPortId }
|
|
DESCRIPTION
|
|
"When a port goes from operational to segmented, a
|
|
trap will be generated. For these purposes, the
|
|
port state will be sampled every XXX seconds, thus
|
|
it will be statistically possible to miss oscillating
|
|
circuits."
|
|
::= 257 -- 0x0101
|
|
|
|
portUnsegementing TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { rptrPortGrpMgmtGrpId,
|
|
rptrPortMgmtPortId }
|
|
DESCRIPTION
|
|
"When it is detected that a previously segmented port
|
|
has gone operational, a trap will be generated. This
|
|
is also sampled, thus a trap may not be generated for
|
|
each transition."
|
|
::= 258 -- 0x0102
|
|
|
|
|
|
|
|
portLinkUp TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { rptrPortGrpMgmtGrpId,
|
|
rptrPortMgmtPortId }
|
|
DESCRIPTION
|
|
"This trap will be generated when it is determined
|
|
that a MAU has been attached to the MMAC. This is
|
|
only appropriate for MIMs that support the concept
|
|
of a link state."
|
|
::= 259 -- 0x0103
|
|
|
|
portLinkDown TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { rptrPortGrpMgmtGrpId,
|
|
rptrPortMgmtPortId }
|
|
DESCRIPTION
|
|
"This trap will be generated when a previously attached
|
|
MAU is removed or powered down. Again, this is only
|
|
appropriate for MIM's that support link state."
|
|
::= 260 -- 0x0104
|
|
|
|
srcaddrNew TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { rptrPortGrpMgmtGrpId,
|
|
rptrPortMgmtPortId,
|
|
rptrPortSrcAddrAddressList }
|
|
DESCRIPTION
|
|
"This trap will be generated when the MMAC detects
|
|
the existence of a new source address on one of it's
|
|
ports."
|
|
::= 261 -- 0x0105
|
|
|
|
srcaddrTimeout TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { rptrPortGrpMgmtGrpId,
|
|
rptrPortMgmtPortId,
|
|
rptrPortSrcAddrAddressList }
|
|
DESCRIPTION
|
|
"This trap will indicate that the MMAC has not
|
|
detected a packet generated by this source address
|
|
within a certain timeout."
|
|
::= 262 -- 0x0106
|
|
|
|
boardRemoval TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { chSlotID }
|
|
DESCRIPTION
|
|
"This trap will be generated when the MMAC detects
|
|
that a MIM has been removed."
|
|
::= 263 -- 0x0107
|
|
|
|
boardInsertion TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { chSlotID,
|
|
deviceType }
|
|
DESCRIPTION
|
|
"This trap will generated when the MMAC determines
|
|
that a new board has been inserted."
|
|
::= 264 -- 0x0108
|
|
|
|
|
|
redundActivePortInCircuitFailed TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { rptrPortGrpMgmtGrpId,
|
|
rptrPortMgmtPortId,
|
|
rptrPortRedundCrctNum }
|
|
DESCRIPTION
|
|
"This trap will be generated when the active port in
|
|
a redundant circuit has failed polling. This will
|
|
indicate the activation of redundancy."
|
|
::= 265 -- 0x0109
|
|
|
|
redundPortActivated TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { rptrPortGrpMgmtGrpId,
|
|
rptrPortMgmtPortId,
|
|
rptrPortRedundCrctNum }
|
|
DESCRIPTION
|
|
"This trap indicates that a new port has been
|
|
activated in a redundant circuit. This does NOT
|
|
indicate that this port is usable, but is being
|
|
tested. If the port fails, a failure trap (above)
|
|
will be generated."
|
|
::= 266 -- 0x010A
|
|
|
|
redundPortTestFailed TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { rptrPortGrpMgmtGrpId,
|
|
rptrPortMgmtPortId,
|
|
rptrPortRedundCrctNum }
|
|
DESCRIPTION
|
|
"This trap will be generated when the MMAC executes
|
|
it's periodic redundancy diagnostics and finds one
|
|
of the ports in a redundant circuit has failed.
|
|
This message will not indicate that redundancy has
|
|
been activated, just that the port has failed and
|
|
should be fixed before it is needed."
|
|
::= 267 -- 0x010B
|
|
|
|
|
|
boardTrafficThresholdExceeded TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { rptrPortGrpAlarmTrafThreshold,
|
|
rptrAlarmsAlarmTimebase,
|
|
rptrPortGrpMgmtGrpId }
|
|
DESCRIPTION
|
|
"This trap will be generated when the traffic (good
|
|
packets per time interval) has been exceeded for a
|
|
particular MIM."
|
|
::= 271 -- 0x010F
|
|
|
|
|
|
boardErrorThresholdExceeded TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { rptrPortGrpAlarmErrThreshold,
|
|
rptrPortGrpAlarmErrSource,
|
|
rptrAlarmsAlarmTimebase,
|
|
rptrPortGrpMgmtGrpId }
|
|
DESCRIPTION
|
|
"This trap will be generated when packets of the
|
|
selected error type exceeds a threshold percentage of
|
|
the good packets for a particular interval for a
|
|
particular MIM."
|
|
::= 272 -- 0x0110
|
|
|
|
|
|
boardCollsionThresholdExceeded TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { rptrPortGrpAlarmCollThreshold,
|
|
rptrAlarmsAlarmTimebase,
|
|
rptrPortGrpMgmtGrpId }
|
|
DESCRIPTION
|
|
"This trap will be generated when collisions exceed a
|
|
threshold percentage of the good packets for a particular
|
|
interval for a particular MIM."
|
|
::= 273 -- 0x0111
|
|
|
|
|
|
portTrafficThresholdExceeded TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { rptrPortAlarmTrafThreshold,
|
|
rptrAlarmsAlarmTimebase,
|
|
rptrPortGrpMgmtGrpId,
|
|
rptrPortMgmtPortId }
|
|
DESCRIPTION
|
|
"This trap will be generated when the traffic (good
|
|
packets per time interval) has been exceeded for a
|
|
particular port."
|
|
::= 274 -- 0x0112
|
|
|
|
|
|
portErrorThresholdExceeded TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { rptrPortAlarmErrThreshold,
|
|
rptrPortAlarmErrSource,
|
|
rptrAlarmsAlarmTimebase,
|
|
rptrPortGrpMgmtGrpId,
|
|
rptrPortMgmtPortId }
|
|
DESCRIPTION
|
|
"This trap will be generated when packets of the
|
|
selected error type exceeds a threshold percentage of
|
|
the good packets for a particular interval for a
|
|
particular port."
|
|
::= 275 -- 0x0113
|
|
|
|
|
|
portCollsionThresholdExceeded TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { rptrPortAlarmCollThreshold,
|
|
rptrAlarmsAlarmTimebase,
|
|
rptrPortGrpMgmtGrpId,
|
|
rptrPortMgmtPortId }
|
|
DESCRIPTION
|
|
"This trap will be generated when collisions exceed a
|
|
threshold percentage of the good packets for a particular
|
|
interval for a particular port."
|
|
::= 276 -- 0x0114
|
|
|
|
|
|
portTypeChanged TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { rptrPortGrpMgmtGrpId,
|
|
rptrPortMgmtPortId,
|
|
rptrPortSrcAddrTopoState }
|
|
DESCRIPTION
|
|
"This trap indicates that a port has changed from a
|
|
station port to a trunk port or vice versa."
|
|
::= 277 -- 0x0115
|
|
|
|
portSecurityViolation TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { rptrPortGrpMgmtGrpId,
|
|
rptrPortMgmtPortId,
|
|
rptrPortSrcAddrAddressList }
|
|
|
|
DESCRIPTION
|
|
"This trap is generated when a source address other
|
|
than those locked to a port is seen."
|
|
::= 279 -- 0x0117
|
|
|
|
portViolationReset TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { rptrPortGrpMgmtGrpId,
|
|
rptrPortMgmtPortId }
|
|
DESCRIPTION
|
|
"This trap is generated when management intervention
|
|
has reset a port after a violation has occurred."
|
|
::= 280 -- 0x0118
|
|
|
|
envTempWarm TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { chSlotID }
|
|
DESCRIPTION
|
|
"This trap is generated when the device detects that
|
|
the temperature within a MIM has reached a WARM
|
|
condition."
|
|
::= 281 -- 0x0119
|
|
|
|
envTempHot TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { chSlotID }
|
|
DESCRIPTION
|
|
"This trap is generated when the device detects that
|
|
the temperature within a MIM has reached a HOT
|
|
condition."
|
|
::= 282 -- 0x011A
|
|
|
|
envVoltageLow TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { powerSupplyNum }
|
|
DESCRIPTION
|
|
"This trap is generated when a power supply's voltage
|
|
is LOW."
|
|
::= 283 -- 0x011B
|
|
|
|
envTempNormal TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { chSlotID }
|
|
DESCRIPTION
|
|
"This trap is generated when the device detects that
|
|
the temperature within a MIM has returned to a
|
|
NORMAL state."
|
|
::= 284 -- 0x011C
|
|
|
|
|
|
envVoltageNormal TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
DESCRIPTION
|
|
"This trap is generated when all power supplies' voltage
|
|
have returned to a NORMAL state."
|
|
::= 285 -- 0x011D
|
|
|
|
|
|
fanFail TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
DESCRIPTION
|
|
"This trap is generated when the device detects that
|
|
the system fans have failed."
|
|
::= 286 -- 0x011E
|
|
|
|
fanNormal TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
DESCRIPTION
|
|
"This trap is generated when the device detects that
|
|
the system fans have returned to normal."
|
|
::= 287 -- 0x011F
|
|
|
|
|
|
boardBroadcastThresholdExceeded TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { rptrPortGrpAlarmBroadThreshold,
|
|
rptrAlarmsAlarmTimebase,
|
|
rptrPortGrpMgmtGrpId }
|
|
DESCRIPTION
|
|
"This trap is generated when the broadcast packets
|
|
(per time interval) have exceeded the threshold for
|
|
the given board."
|
|
::= 289 -- 0x0121
|
|
|
|
|
|
portBroadcastThresholdExceeded TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { rptrPortAlarmBroadThreshold,
|
|
rptrAlarmsAlarmTimebase,
|
|
rptrPortGrpMgmtGrpId,
|
|
rptrPortMgmtPortId }
|
|
DESCRIPTION
|
|
"This trap is generated when the broadcast packets
|
|
(per time interval) have exceeded the threshold for
|
|
the given port."
|
|
::= 290 -- 0x0122
|
|
|
|
systemVoltageLow TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
DESCRIPTION
|
|
"This trap is generated when the device detects that
|
|
the power to the EMME is low."
|
|
::= 293 -- 0x0125
|
|
|
|
systemVoltageNormal TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
DESCRIPTION
|
|
"This trap is generated when the device detects that
|
|
the power to the EMME has returned to normal."
|
|
::= 294 -- 0x0126
|
|
|
|
|
|
epimRemoval TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { rptrPortGrpMgmtGrpId,
|
|
rptrPortMgmtPortId }
|
|
DESCRIPTION
|
|
"This trap is generated when it is detected that an
|
|
EPIM has been removed."
|
|
::= 295 -- 0x0127
|
|
|
|
epimInsertion TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { rptrPortGrpMgmtGrpId,
|
|
rptrPortMgmtPortId,
|
|
rptrPortMgmtPortType }
|
|
DESCRIPTION
|
|
"This trap is generated when it is detected that an
|
|
EPIM has been inserted."
|
|
::= 296 -- 0x0128
|
|
|
|
|
|
rptrTrafficThresholdExceeded TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { rptrAlarmsTrafThreshold,
|
|
rptrAlarmsAlarmTimebase,
|
|
rptrMgmtInterfaceNum }
|
|
DESCRIPTION
|
|
"This trap will be generated when the traffic (good
|
|
packets per time interval) has been exceeded for a
|
|
network."
|
|
::= 297 -- 0x0129
|
|
|
|
|
|
rptrErrorThresholdExceeded TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { rptrAlarmsErrThreshold,
|
|
rptrAlarmsErrSource,
|
|
rptrAlarmsAlarmTimebase,
|
|
rptrMgmtInterfaceNum }
|
|
DESCRIPTION
|
|
"This trap will be generated when packets of the
|
|
selected error type exceeds a threshold percentage of
|
|
the good packets for a particular interval for an
|
|
entire network."
|
|
::= 304 -- 0x0130
|
|
|
|
|
|
rptrCollsionThresholdExceeded TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { rptrAlarmsCollThreshold,
|
|
rptrAlarmsAlarmTimebase,
|
|
rptrMgmtInterfaceNum }
|
|
DESCRIPTION
|
|
"This trap will be generated when collisions exceed a
|
|
threshold percentage of the good packets for a particular
|
|
interval for an entire network."
|
|
::= 305 -- 0x0131
|
|
|
|
|
|
rptrLockStatusChanged TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { rptrSrcAddrMgmtPortLock,
|
|
rptrMgmtInterfaceNum }
|
|
DESCRIPTION
|
|
"This trap is generated when the status of the address
|
|
lock changes for a certain network."
|
|
::= 306 -- 0x0132
|
|
|
|
rptrBroadcastThresholdExceeded TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { rptrAlarmsBroadThreshold,
|
|
rptrAlarmsAlarmTimebase,
|
|
rptrMgmtInterfaceNum }
|
|
DESCRIPTION
|
|
"This trap is generated when the broadcast packets
|
|
(per time interval) have exceeded the threshold for
|
|
the given repeater."
|
|
::= 307 -- 0x0133
|
|
|
|
|
|
srcAddressPortLockStatusChange TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { rptrPortGrpMgmtGrpId,
|
|
rptrPortMgmtPortId,
|
|
rptrPortSecurityLockStatus }
|
|
DESCRIPTION
|
|
"This trap is generated when a change to the
|
|
source address locking is detected at the port level."
|
|
::= 309 -- 0x0135
|
|
|
|
chBoardInsertion TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { chSlotID,
|
|
chSlotModuleType }
|
|
DESCRIPTION
|
|
"This trap will generated when the MMAC determines
|
|
that a new board has been inserted."
|
|
::= 310 -- 0x0136
|
|
|
|
portSecureStateChanged TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { rptrPortSecurityPortGrpId,
|
|
rptrPortSecurityPortId,
|
|
rptrPortSecuritySecureState}
|
|
DESCRIPTION
|
|
"This trap is generated when the status of the secure state
|
|
changes for a specific port."
|
|
::= 313 -- 0x139
|
|
|
|
|
|
rptrLearnStateChanged TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { rptrMgmtInterfaceNum,
|
|
rptrSecurityLearnState }
|
|
DESCRIPTION
|
|
"This trap is generated when network learning is reset.
|
|
When learning is reset, all secure addresses on each
|
|
port, within the network, will be deleted and ports will
|
|
learn source addresses, again."
|
|
::= 314 -- 0x13A
|
|
|
|
rptrPortGrpLearnStateChanged TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { rptrPortGrpSrcAddrLockGrpId,
|
|
rptrPortGrpSASecurityLearnState }
|
|
DESCRIPTION
|
|
"This trap is generated when port group learning is reset.
|
|
When learning is reset, all secure addresses on each port,
|
|
within the port group, will be deleted and ports will learn
|
|
source addresses, again."
|
|
::= 315 -- 0x13B
|
|
|
|
rptrPortLearnStateChanged TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { rptrPortSecurityPortGrpId,
|
|
rptrPortSecurityPortId,
|
|
rptrPortSecurityLearnState }
|
|
DESCRIPTION
|
|
"This trap is generated when learning on a port is reset.
|
|
When learning is reset, all secure addresses on the port
|
|
will be deleted and the port will learn source addresses,
|
|
again."
|
|
::= 316 -- 0x13C
|
|
|
|
rptrLearnModeChanged TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { rptrMgmtInterfaceNum,
|
|
rptrSecurityLearnMode }
|
|
DESCRIPTION
|
|
"This trap is generated when network learn mode is
|
|
changed between one-time learn mode and continuous
|
|
learn mode."
|
|
::= 317 -- 0x13D
|
|
|
|
portGrpLearnModeChanged TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { rptrPortGrpSrcAddrLockGrpId,
|
|
rptrPortGrpSASecurityLearnMode }
|
|
DESCRIPTION
|
|
"This trap is generated when the port group learn
|
|
mode is changed between one-time learn mode and
|
|
continuous learn mode."
|
|
::= 318 -- 0x13E
|
|
|
|
portLearnModeChanged TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { rptrPortSecurityPortGrpId,
|
|
rptrPortSecurityPortId,
|
|
rptrPortSecurityLearnMode }
|
|
DESCRIPTION
|
|
"This trap is generated when the port learn
|
|
mode is changed between one-time learn mode and
|
|
continuous learn mode."
|
|
::= 319 -- 0x13F
|
|
|
|
|
|
|
|
fpportActivated TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { rptrPortMgmtPortId }
|
|
DESCRIPTION
|
|
"This trap is generated when a port is activated in
|
|
redundancy due to another port failing."
|
|
::= 400 -- 0x0190
|
|
|
|
|
|
interfacePortInsertion TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ctIfNumber, ctIfPortPortNumber, ctIfPortType }
|
|
DESCRIPTION
|
|
"This trap will be generated when it is detected that an
|
|
interface port has been inserted."
|
|
::= 416 -- 0x1A0
|
|
|
|
|
|
interfacePortRemoval TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ctIfNumber, ctIfPortPortNumber }
|
|
DESCRIPTION
|
|
"This trap will be generated when it is detected that an
|
|
interface port has been removed."
|
|
::= 417 -- 0x1A1
|
|
|
|
interfacePortLinkUp TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ctIfNumber, ctIfPortPortNumber }
|
|
DESCRIPTION
|
|
"This trap will be generated when it is determined that
|
|
a port on a strictly bridging interface (not a 'repeater')
|
|
has been connected to a LAN. This is only appropriate
|
|
for ports that support the concept of a link state."
|
|
::= 418 -- 0x1A2
|
|
|
|
interfacePortLinkDown TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ctIfNumber, ctIfPortPortNumber }
|
|
DESCRIPTION
|
|
"This trap will be generated when a previously attached
|
|
bridging port has been disconnected from a LAN. This is
|
|
only appropriate for ports that support the concept of a
|
|
link state."
|
|
::= 419 -- 0x1A3
|
|
|
|
portInserted TRAP-TYPE
|
|
-- STATUS deprecated
|
|
ENTERPRISE cabletron
|
|
VARIABLES { tRingPortGrpId,
|
|
tRingPortMgmtPortId }
|
|
DESCRIPTION
|
|
"This trap is sent when a stations port's link state
|
|
turns on while the management state of the port is
|
|
Enabled."
|
|
::= 513 -- 0x0201
|
|
|
|
portDeInserted TRAP-TYPE
|
|
-- STATUS deprecated
|
|
ENTERPRISE cabletron
|
|
VARIABLES { tRingPortGrpId,
|
|
tRingPortMgmtPortId }
|
|
DESCRIPTION
|
|
"This trap is sent when a stations port's link state
|
|
turns off while the management state of the port is
|
|
Enabled."
|
|
::= 514 -- 0x0202
|
|
|
|
|
|
ringSpeedFault TRAP-TYPE
|
|
-- STATUS deprecated
|
|
ENTERPRISE cabletron
|
|
VARIABLES { tRingPortGrpId }
|
|
DESCRIPTION
|
|
"This trap is sent when a board enters the ring speed
|
|
fault state due to a station or ring port attaching
|
|
to the board as a different speed than the board is
|
|
configured for."
|
|
::= 515 -- 0x0203
|
|
|
|
ringSpeedFaultCleared TRAP-TYPE
|
|
-- STATUS deprecated
|
|
ENTERPRISE cabletron
|
|
VARIABLES { tRingPortGrpId }
|
|
DESCRIPTION
|
|
"This trap is sent when a board leaves the ring
|
|
speed fault state."
|
|
::= 516 -- 0x0204
|
|
|
|
|
|
ringPortFaulted TRAP-TYPE
|
|
-- STATUS deprecated
|
|
ENTERPRISE cabletron
|
|
VARIABLES { tRingPortGrpId,
|
|
tRingPortMgmtPortId }
|
|
DESCRIPTION
|
|
"This trap is sent when a ring port wraps when its
|
|
management state is Active, without regard for the
|
|
selected type of the ring port."
|
|
::= 517 -- 0x0205
|
|
|
|
ringPortFaultCleared TRAP-TYPE
|
|
-- STATUS deprecated
|
|
ENTERPRISE cabletron
|
|
VARIABLES { tRingPortGrpId,
|
|
tRingPortMgmtPortId }
|
|
DESCRIPTION
|
|
"This trap is sent when a ring port unwraps when its
|
|
management state is Active, without regard for the
|
|
selected type of the ring port."
|
|
::= 518 -- 0x0206
|
|
|
|
|
|
beaconState TRAP-TYPE
|
|
-- STATUS deprecated
|
|
ENTERPRISE cabletron
|
|
VARIABLES { tRingStatsRingLastBeaconType,
|
|
tRingMgmtStnName,
|
|
tRingMgmtStnUNA,
|
|
tRingMgmtStnBoard,
|
|
tRingMgmtStnPort }
|
|
DESCRIPTION
|
|
"This trap occurs when a Beacon is detected on the
|
|
ring while the ring is in the Operational state, or
|
|
when the Beacon contains different information than
|
|
the last Beacon received."
|
|
::= 519 -- 0x0207
|
|
|
|
beaconStateCleared TRAP-TYPE
|
|
-- STATUS deprecated
|
|
ENTERPRISE cabletron
|
|
VARIABLES { tRingStatsRingLastBeacon }
|
|
DESCRIPTION
|
|
"This trap occurs when a ring returns to the
|
|
Operational state."
|
|
::= 520 -- 0x0208
|
|
|
|
|
|
stationAdded TRAP-TYPE
|
|
-- STATUS deprecated
|
|
ENTERPRISE cabletron
|
|
VARIABLES { tRingMgmtSecurityAddressAdd }
|
|
DESCRIPTION
|
|
"This trap is sent when a new station address is
|
|
added to the security allowed list"
|
|
::= 521 -- 0x0209
|
|
|
|
|
|
stationRemoved TRAP-TYPE
|
|
-- STATUS deprecated
|
|
ENTERPRISE cabletron
|
|
VARIABLES { tRingMgmtSecurityAddressRemove }
|
|
DESCRIPTION
|
|
"This trap is sent when a station is rejected
|
|
from the ring with a REMOVE MAC command sent
|
|
by the ring security."
|
|
::= 522 -- 0x020a
|
|
|
|
|
|
ringConfigurationChanged TRAP-TYPE
|
|
-- STATUS deprecated
|
|
ENTERPRISE cabletron
|
|
DESCRIPTION
|
|
"This trap is sent when the TRMM has built a
|
|
new station map."
|
|
::= 523 -- 0x020B
|
|
|
|
faultRecoveryPortRemoved TRAP-TYPE
|
|
-- STATUS deprecated
|
|
ENTERPRISE cabletron
|
|
VARIABLES { tRingPortGrpId,
|
|
tRingPortMgmtPortId }
|
|
DESCRIPTION
|
|
"This trap is sent after a fault recovery condition
|
|
has been corrected, and reports that a port was
|
|
removed in the process of correcting the condition."
|
|
::= 524 -- 0x020C
|
|
|
|
|
|
faultRecoveryBoardBypassed TRAP-TYPE
|
|
-- STATUS deprecated
|
|
ENTERPRISE cabletron
|
|
VARIABLES { tRingPortGrpId }
|
|
DESCRIPTION
|
|
"This trap is sent after a fault recovery condition
|
|
has been corrected, and reports that a board was
|
|
bypassed in the process of correcting the condition."
|
|
::= 525 -- 0x020D
|
|
|
|
|
|
portViolation TRAP-TYPE
|
|
-- STATUS deprecated
|
|
ENTERPRISE cabletron
|
|
VARIABLES { tRingPortGrpId,
|
|
tRingPortMgmtPortId }
|
|
DESCRIPTION
|
|
"This trap is sent when a port link state turns on
|
|
and the port's management state is Disabled."
|
|
::= 526 -- 0x020E
|
|
|
|
portViolationCleared TRAP-TYPE
|
|
-- STATUS deprecated
|
|
ENTERPRISE cabletron
|
|
VARIABLES { tRingPortGrpId,
|
|
tRingPortMgmtPortId }
|
|
DESCRIPTION
|
|
"This trap is sent when a port link state turns off
|
|
and the port's management state is Disabled."
|
|
::= 527 -- 0x020F
|
|
|
|
|
|
|
|
faultRecoveryOscillation TRAP-TYPE
|
|
-- STATUS deprecated
|
|
ENTERPRISE cabletron
|
|
DESCRIPTION
|
|
"This trap is sent when the ring has oscillated several
|
|
times within a short amount of time. The ring is
|
|
considered oscillating if it has failed a short time
|
|
after recovering."
|
|
::= 528 -- 0x0210
|
|
|
|
ringPurgeThreshold TRAP-TYPE
|
|
-- STATUS deprecated
|
|
ENTERPRISE cabletron
|
|
VARIABLES { tRingAlarmsRingRingPurgesThreshold,
|
|
tRingAlarmsRingTimebase }
|
|
DESCRIPTION
|
|
"This trap is sent when ring purge errors have exceeded
|
|
the specified threshold value."
|
|
::= 529 -- 0x0211
|
|
|
|
|
|
amErrorsThreshold TRAP-TYPE
|
|
-- STATUS deprecated
|
|
ENTERPRISE cabletron
|
|
VARIABLES { tRingAlarmsRingAMPErrsThreshold,
|
|
tRingAlarmsRingTimebase }
|
|
DESCRIPTION
|
|
"This trap is sent when Active Monitor errors have exceeded
|
|
the specified threshold value."
|
|
::= 530 -- 0x0212
|
|
|
|
|
|
tokenErrorsThreshold TRAP-TYPE
|
|
-- STATUS deprecated
|
|
ENTERPRISE cabletron
|
|
VARIABLES { tRingAlarmsRingTokenErrsThreshold,
|
|
tRingAlarmsRingTimebase }
|
|
DESCRIPTION
|
|
"This trap is sent when Token errors have exceeded
|
|
the specified threshold value."
|
|
::= 531 -- 0x0213
|
|
|
|
|
|
claimTokenThreshold TRAP-TYPE
|
|
-- STATUS deprecated
|
|
ENTERPRISE cabletron
|
|
VARIABLES { tRingAlarmsRingClaimTknThreshold,
|
|
tRingAlarmsRingTimebase }
|
|
DESCRIPTION
|
|
"This trap is sent when claim tokens have exceeded
|
|
the specified threshold value."
|
|
::= 532 -- 0x0214
|
|
|
|
|
|
lostFramesThreshold TRAP-TYPE
|
|
-- STATUS deprecated
|
|
ENTERPRISE cabletron
|
|
VARIABLES { tRingAlarmsRingLostFramesThreshold,
|
|
tRingAlarmsRingTimebase }
|
|
DESCRIPTION
|
|
"This trap is sent when the Lost Frame count has exceeded
|
|
the specified threshold value."
|
|
::= 533 -- 0x0215
|
|
|
|
|
|
beaconStateThreshold TRAP-TYPE
|
|
-- STATUS deprecated
|
|
ENTERPRISE cabletron
|
|
VARIABLES { tRingAlarmsRingBeaconStateThreshold,
|
|
tRingAlarmsRingTimebase }
|
|
DESCRIPTION
|
|
"This trap is sent when the Beacon State count has exceeded
|
|
the specified threshold value."
|
|
::= 534 -- 0x0216
|
|
|
|
|
|
frameCountThreshold TRAP-TYPE
|
|
-- STATUS deprecated
|
|
ENTERPRISE cabletron
|
|
VARIABLES { tRingAlarmsRingFrameCountThreshold,
|
|
tRingAlarmsRingTimebase }
|
|
DESCRIPTION
|
|
"This trap is sent when the frame count has exceeded
|
|
the specified threshold value."
|
|
::= 535 -- 0x0217
|
|
|
|
|
|
lineErrorsThreshold TRAP-TYPE
|
|
-- STATUS deprecated
|
|
ENTERPRISE cabletron
|
|
VARIABLES { tRingAlarmsStnThrshLineErrsThreshold,
|
|
tRingAlarmsRingTimebase,
|
|
tRingAlarmsStnThrshAddress }
|
|
DESCRIPTION
|
|
"This trap is sent when the line errors have exceeded
|
|
the specified threshold value for the station."
|
|
::= 536 -- 0x0218
|
|
|
|
|
|
internalErrorsThreshold TRAP-TYPE
|
|
-- STATUS deprecated
|
|
ENTERPRISE cabletron
|
|
VARIABLES { tRingAlarmsStnThrshInternalErrsThreshold,
|
|
tRingAlarmsRingTimebase,
|
|
tRingAlarmsStnThrshAddress }
|
|
DESCRIPTION
|
|
"This trap is sent when the Lost internal errors have exceeded
|
|
the specified threshold value for the station."
|
|
::= 537 -- 0x0219
|
|
|
|
|
|
burstErrorsThreshold TRAP-TYPE
|
|
-- STATUS deprecated
|
|
ENTERPRISE cabletron
|
|
VARIABLES { tRingAlarmsStnThrshBurstErrsThreshold,
|
|
tRingAlarmsRingTimebase,
|
|
tRingAlarmsStnThrshAddress }
|
|
DESCRIPTION
|
|
"This trap is sent when the Lost burst errors have exceeded
|
|
the specified threshold value for the station."
|
|
::= 538 -- 0x021A
|
|
|
|
|
|
acErrorsThreshold TRAP-TYPE
|
|
-- STATUS deprecated
|
|
ENTERPRISE cabletron
|
|
VARIABLES { tRingAlarmsStnThrshACErrsThreshold,
|
|
tRingAlarmsRingTimebase,
|
|
tRingAlarmsStnThrshAddress }
|
|
DESCRIPTION
|
|
"This trap is sent when address/copied errors have exceeded
|
|
the specified threshold value for the station."
|
|
::= 539 -- 0x021B
|
|
|
|
|
|
receiverCongestionThreshold TRAP-TYPE
|
|
-- STATUS deprecated
|
|
ENTERPRISE cabletron
|
|
VARIABLES { tRingAlarmsStnThrshRcvrCongestThreshold,
|
|
tRingAlarmsRingTimebase,
|
|
tRingAlarmsStnThrshAddress }
|
|
DESCRIPTION
|
|
"This trap is sent when receiver congestion errors have exceeded
|
|
the specified threshold value for the station."
|
|
::= 540 -- 0x021C
|
|
|
|
|
|
removeStationFailure TRAP-TYPE
|
|
-- STATUS deprecated
|
|
ENTERPRISE cabletron
|
|
VARIABLES { tRingMgmtSecurityAddressRemove }
|
|
DESCRIPTION
|
|
"This trap is sent when a station breaks through security
|
|
and cannot be removed from the ring."
|
|
::= 541 -- 0x021D
|
|
|
|
ringSpeedPortFault TRAP-TYPE
|
|
-- STATUS deprecated
|
|
ENTERPRISE cabletron
|
|
VARIABLES { tRingPortGrpId, tRingPortMgmtPortId }
|
|
DESCRIPTION
|
|
"This trap is generated when a port enters the ring speed
|
|
fault state due to a station or ring port attaching to the
|
|
port at a different speed than the port is configured for."
|
|
::= 542 -- 0x21E
|
|
|
|
ringSpeedPortFaultCleared TRAP-TYPE
|
|
-- STATUS deprecated
|
|
ENTERPRISE cabletron
|
|
VARIABLES { tRingPortGrpId, tRingPortMgmtPortId }
|
|
DESCRIPTION
|
|
"This trap is generated when a port leaves the ring speed
|
|
fault state."
|
|
::= 543 -- 0x21F
|
|
|
|
stnPortInserted TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { chSlotID,
|
|
tRingPortGrpId,
|
|
tRingPortMgmtPortId }
|
|
DESCRIPTION
|
|
"This trap is sent when a stations port's link state
|
|
turns on while the management state of the port is
|
|
Enabled."
|
|
::= 544 -- 0x0220
|
|
|
|
stnPortDeInserted TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { chSlotID,
|
|
tRingPortGrpId,
|
|
tRingPortMgmtPortId }
|
|
DESCRIPTION
|
|
"This trap is sent when a stations port's link state
|
|
turns off while the management state of the port is
|
|
Enabled."
|
|
::= 545 -- 0x0221
|
|
|
|
boardRingSpeedFault TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { chSlotID}
|
|
DESCRIPTION
|
|
"This trap is sent when a 'active NON-93 series' board
|
|
enters the ring speed fault state due to a station or ring
|
|
port attaching to the board as a different speed than the
|
|
board is configured for."
|
|
::= 546 -- 0x0222
|
|
|
|
boardRingSpeedFaultCleared TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { chSlotID}
|
|
DESCRIPTION
|
|
"This trap is sent when a board leaves the ring
|
|
speed fault state."
|
|
::= 547 -- 0x0223
|
|
|
|
ringPortWrapped TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { chSlotID,
|
|
tRingPortGrpId,
|
|
tRingPortMgmtPortId }
|
|
DESCRIPTION
|
|
"This trap is sent when a ring port wraps when its
|
|
management state is Active, without regard for the
|
|
selected type of the ring port."
|
|
::= 548 -- 0x0224
|
|
|
|
ringPortWrapCleared TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { chSlotID,
|
|
tRingPortGrpId,
|
|
tRingPortMgmtPortId }
|
|
DESCRIPTION
|
|
"This trap is sent when a ring port unwraps when its
|
|
management state is Active, without regard for the
|
|
selected type of the ring port."
|
|
::= 549 -- 0x225
|
|
|
|
|
|
beaconingState TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex,
|
|
tRingMgmtStnName,
|
|
tRingMgmtStnAddress,
|
|
tRingMgmtStnUNA,
|
|
tRingMgmtStnBoard,
|
|
tRingPortGrpId,
|
|
tRingMgmtStnPort,
|
|
tRingStatsRingLastBeaconType }
|
|
DESCRIPTION
|
|
"This trap occurs, if beacon recovery is enabled,
|
|
when Beaconing, Ring Purging or Claim Tokens are detected
|
|
on the ring while the ring is in the Operational state, or
|
|
when the Beacon contains different information than
|
|
the last Beacon received."
|
|
::= 550 -- 0x0226
|
|
|
|
beaconingStateCleared TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex,
|
|
tRingStatsRingLastBeacon }
|
|
DESCRIPTION
|
|
"This trap occurs when a ring returns to the
|
|
Operational state."
|
|
::= 551 -- 0x0227
|
|
|
|
stnAdded TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex, tRingMgmtSecurityAddressAdd }
|
|
DESCRIPTION
|
|
"This trap is sent when a new station is added to the
|
|
security allowed list."
|
|
::= 552 -- 0x0228
|
|
|
|
stnRemoved TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex,
|
|
tRingMgmtSecurityAddressRemove }
|
|
DESCRIPTION
|
|
"This trap is sent when a station is rejected
|
|
from the ring with a REMOVE MAC command sent
|
|
by the ring security."
|
|
::= 553 -- 0x0229
|
|
|
|
removeStnFailure TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex,
|
|
tRingMgmtSecurityAddressRemove }
|
|
DESCRIPTION
|
|
"This trap is sent when a station breaks through security
|
|
and cannot be removed from the ring."
|
|
::= 554 -- 0x022A
|
|
|
|
|
|
ringSecurityPortRemoved TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { chSlotID,
|
|
tRingPortGrpId,
|
|
tRingPortMgmtPortId }
|
|
DESCRIPTION
|
|
"This trap is sent when a ring security break
|
|
has been corrected, and reports that a port was
|
|
removed (disabled) in the process of correcting the condition."
|
|
::= 555 -- 0x022B
|
|
|
|
beaconRecoveryPortRemoved TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { chSlotID,
|
|
tRingPortGrpId,
|
|
tRingPortMgmtPortId }
|
|
DESCRIPTION
|
|
"This trap is sent after a fault recovery condition
|
|
has been corrected, and reports that a port was
|
|
removed in the process of correcting the condition."
|
|
::= 556 -- 0x022C
|
|
|
|
|
|
beaconRecoveryPortGroupBypassed TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { chSlotID,tRingPortGrpId }
|
|
DESCRIPTION
|
|
"This trap is sent after a fault recovery condition
|
|
has been corrected, and reports that a port group was
|
|
bypassed in the process of correcting the condition."
|
|
::= 557 -- 0x022D
|
|
|
|
beaconRecoveryBoardBypassed TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { chSlotID }
|
|
DESCRIPTION
|
|
"This trap is sent after a fault recovery condition
|
|
has been corrected, and reports that a board was
|
|
bypassed in the process of correcting the condition."
|
|
::= 558 -- 0x022E
|
|
|
|
portLinkViolation TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { chSlotID,
|
|
tRingPortGrpId,
|
|
tRingPortMgmtPortId }
|
|
DESCRIPTION
|
|
"This trap is sent when a port link state turns on
|
|
and the port's management state is Disabled."
|
|
::= 559 -- 0x022F
|
|
|
|
portLinkViolationCleared TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { chSlotID,
|
|
tRingPortGrpId,
|
|
tRingPortMgmtPortId }
|
|
DESCRIPTION
|
|
"This trap is sent when a port link state turns off
|
|
and the port's management state is Disabled."
|
|
::= 560 -- 0x0230
|
|
|
|
ringPurgeTotalThreshold TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex,
|
|
tRingAlarmsRingRingPurgesThreshold,
|
|
tRingAlarmsRingTimebase }
|
|
DESCRIPTION
|
|
"This trap is sent when ring purge errors have exceeded
|
|
the specified threshold value."
|
|
::= 561 -- 0x0231
|
|
|
|
|
|
amErrorsTotalThreshold TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex,
|
|
tRingAlarmsRingAMPErrsThreshold,
|
|
tRingAlarmsRingTimebase }
|
|
DESCRIPTION
|
|
"This trap is sent when Active Monitor errors have exceeded
|
|
the specified threshold value."
|
|
::= 562 -- 0x0232
|
|
|
|
|
|
tokenErrorsTotalThreshold TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex,
|
|
tRingAlarmsRingTokenErrsThreshold,
|
|
tRingAlarmsRingTimebase }
|
|
DESCRIPTION
|
|
"This trap is sent when Token errors have exceeded
|
|
the specified threshold value."
|
|
::= 563 -- 0x0233
|
|
|
|
|
|
claimTokenTotalThreshold TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex,
|
|
tRingAlarmsRingClaimTknThreshold,
|
|
tRingAlarmsRingTimebase }
|
|
DESCRIPTION
|
|
"This trap is sent when claim tokens have exceeded
|
|
the specified threshold value."
|
|
::= 564 -- 0x0234
|
|
|
|
lostFramesTotalThreshold TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex,
|
|
tRingAlarmsRingLostFramesThreshold,
|
|
tRingAlarmsRingTimebase }
|
|
DESCRIPTION
|
|
"This trap is sent when the Lost Frame count has exceeded
|
|
the specified threshold value."
|
|
::= 565 -- 0x0235
|
|
|
|
frameCountTotalThreshold TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex,
|
|
tRingAlarmsRingFrameCountThreshold,
|
|
tRingAlarmsRingTimebase }
|
|
DESCRIPTION
|
|
"This trap is sent when the frame count has exceeded
|
|
the specified threshold value."
|
|
::= 566 -- 0x0236
|
|
|
|
|
|
lineErrorsStnThreshold TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex,
|
|
tRingAlarmsStnThrshLineErrsThreshold,
|
|
tRingAlarmsRingTimebase,
|
|
tRingAlarmsStnThrshAddress }
|
|
DESCRIPTION
|
|
"This trap is sent when the line errors have exceeded
|
|
the specified threshold value for the station."
|
|
::= 567 -- 0x0237
|
|
|
|
|
|
internalErrorsStnThreshold TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex,
|
|
tRingAlarmsStnThrshInternalErrsThreshold,
|
|
tRingAlarmsRingTimebase,
|
|
tRingAlarmsStnThrshAddress }
|
|
DESCRIPTION
|
|
"This trap is sent when the Lost internal errors have exceeded
|
|
the specified threshold value for the station."
|
|
::= 568 -- 0x0238
|
|
|
|
|
|
burstErrorsStnThreshold TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex,
|
|
tRingAlarmsStnThrshBurstErrsThreshold,
|
|
tRingAlarmsRingTimebase,
|
|
tRingAlarmsStnThrshAddress }
|
|
DESCRIPTION
|
|
"This trap is sent when the Lost burst errors have exceeded
|
|
the specified threshold value for the station."
|
|
::= 569 -- 0x0239
|
|
|
|
|
|
acErrorsStnThreshold TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex,
|
|
tRingAlarmsStnThrshACErrsThreshold,
|
|
tRingAlarmsRingTimebase,
|
|
tRingAlarmsStnThrshAddress }
|
|
DESCRIPTION
|
|
"This trap is sent when address/copied errors have exceeded
|
|
the specified threshold value for the station."
|
|
::= 570 -- 0x023A
|
|
|
|
|
|
receiverCongestionStnThreshold TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex,
|
|
tRingAlarmsStnThrshRcvrCongestThreshold,
|
|
tRingAlarmsRingTimebase,
|
|
tRingAlarmsStnThrshAddress }
|
|
DESCRIPTION
|
|
"This trap is sent when receiver congestion errors have exceeded
|
|
the specified threshold value for the station."
|
|
::= 571 -- 0x023B
|
|
|
|
|
|
ringSpeedPortFaulted TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { chSlotID,
|
|
tRingPortGrpId,
|
|
tRingPortMgmtPortId }
|
|
DESCRIPTION
|
|
"This trap is generated when a port enters the ring speed
|
|
fault state due to a station or ring port attaching to the
|
|
port at a different speed than the port is configured for."
|
|
::= 572 -- 0x023C
|
|
|
|
|
|
ringSpeedPortFaultedCleared TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { chSlotID,
|
|
tRingPortGrpId,
|
|
tRingPortMgmtPortId }
|
|
DESCRIPTION
|
|
"This trap is generated when a port leaves the ring speed
|
|
fault state."
|
|
::= 573 -- 0x023D
|
|
|
|
|
|
tpimInserted TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { chSlotID,
|
|
tRingPortGrpId,
|
|
tRingPortMgmtPortId }
|
|
DESCRIPTION
|
|
"This trap is generated when a TPIM is installed."
|
|
::= 574 -- 0x023E
|
|
|
|
tpimRemoved TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { chSlotID,
|
|
tRingPortGrpId,
|
|
tRingPortMgmtPortId }
|
|
DESCRIPTION
|
|
"This trap is generated when a TPIM is removed."
|
|
::= 575 -- 0x023F
|
|
|
|
neighborNotificationInc TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex }
|
|
DESCRIPTION
|
|
"This trap is sent each time the neighbor notification (ring
|
|
poll) does not complete."
|
|
::= 576 -- 0x0240
|
|
|
|
fltRecoveryOscillation TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex }
|
|
DESCRIPTION
|
|
"This trap is sent when the ring has oscillated (in
|
|
and out of beaconing) when beacon recovery is enabled.
|
|
The ring is considered oscillating if it has
|
|
failed 21 secs after recovering from the previous."
|
|
::= 577 -- 0x0241
|
|
|
|
ringPollFailureEventCorrected TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex,
|
|
tRingMgmtStnAddress,
|
|
tRingMgmtStnDNA,
|
|
tRingMgmtStnBoard,
|
|
tRingMgmtStnPort }
|
|
DESCRIPTION
|
|
"This trap is sent after the management module successfully
|
|
recovered the Ring Poll Failure condition."
|
|
::= 578 -- 0x0242
|
|
|
|
ringPollFailureEventNotCorrected TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex,
|
|
tRingMgmtStnAddress }
|
|
DESCRIPTION
|
|
"This trap is sent after the management module has failed to
|
|
recover the Ring Poll Failure condition. The interesting
|
|
information includes the interface number and the MAC address
|
|
of the last successful ring poll station."
|
|
::= 579 -- 0x0243
|
|
|
|
sPVP TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
-- VARIABLES { spvpAtmAddress,
|
|
-- timeStamp,
|
|
-- releaseCause }
|
|
DESCRIPTION
|
|
"This trap indicates that a SPVP was rerouted.
|
|
The variables indicates the address of a rerouted spvp, the time
|
|
stamp of when rerouting occurred, and the cause of rerouting.
|
|
The cause codes are as follows:
|
|
Unallocated (unassigned) number = 1
|
|
No route to specified transit network = 2
|
|
No route to destination = 3
|
|
Normal call clearing = 16
|
|
User busy = 17
|
|
No user responding = 18
|
|
Call rejected = 21
|
|
Number changed = 22
|
|
User rejects all calls with calling line
|
|
identification restriction (CLIR) = 23
|
|
Destination out of order = 27
|
|
Invalid number format (address incomplete) = 28
|
|
Response to STATUS ENQUIRY = 30
|
|
Normal, unspecified = 31
|
|
Requested VPCI/VCI not available = 35
|
|
VPCI/VCI assignment failure = 36
|
|
User cell rate not available = 37
|
|
Network out of order = 38
|
|
Temporary failure = 41
|
|
Access information discarded = 43
|
|
No VPCI/VCI available = 45
|
|
Resource unavailable, unspecified = 47
|
|
Quality of Service unavailable = 49
|
|
Bearer capability not authorized = 57
|
|
Bearer capability not presently available = 58
|
|
Service or option not available, unspecified = 63
|
|
Bearer capability not implemented = 65
|
|
Unsupported combination of traffic parameters = 73
|
|
AAL parameters cannot be supported = 78
|
|
Invalid call reference value = 81
|
|
Identified channel does not exist = 82
|
|
Incompatible destination = 88
|
|
Invalid endpoint reference = 89
|
|
Invalid transit network selection = 91
|
|
Too many pending add party requests = 92
|
|
Mandatory information element missing = 96
|
|
Message type non-existent or not implemented = 97
|
|
Information element non existent or not implemented = 99
|
|
Invalid information element contents = 100
|
|
Message not compatible with call state = 101
|
|
Recovery on timer expiry = 102
|
|
Incorrect message length = 104
|
|
Protocol error, unspecified = 111"
|
|
::= 580 -- 0x0244
|
|
|
|
sPVC TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
-- VARIABLES { spvcAtmAddress,
|
|
-- timeStamp,
|
|
-- releaseCause }
|
|
DESCRIPTION
|
|
"This trap indicates that a SPVC was rerouted.
|
|
The variables indicates the address of a rerouted spvc, the time
|
|
stamp of when rerouting occurred, and the cause of rerouting.
|
|
The cause codes are as follows:
|
|
Unallocated (unassigned) number = 1
|
|
No route to specified transit network = 2
|
|
No route to destination = 3
|
|
Normal call clearing = 16
|
|
User busy = 17
|
|
No user responding = 18
|
|
Call rejected = 21
|
|
Number changed = 22
|
|
User rejects all calls with calling line identification
|
|
restriction (CLIR) = 23
|
|
Destination out of order = 27
|
|
Invalid number format (address incomplete) = 28
|
|
Response to STATUS ENQUIRY = 30
|
|
Normal, unspecified = 31
|
|
Requested VPCI/VCI not available = 35
|
|
VPCI/VCI assignment failure = 36
|
|
User cell rate not available = 37
|
|
Network out of order = 38
|
|
Temporary failure = 41
|
|
Access information discarded = 43
|
|
No VPCI/VCI available = 45
|
|
Resource unavailable, unspecified = 47
|
|
Quality of Service unavailable = 49
|
|
Bearer capability not authorized = 57
|
|
Bearer capability not presently available = 58
|
|
Service or option not available, unspecified = 63
|
|
Bearer capability not implemented = 65
|
|
Unsupported combination of traffic parameters = 73
|
|
AAL parameters cannot be supported = 78
|
|
Invalid call reference value = 81
|
|
Identified channel does not exist = 82
|
|
Incompatible destination = 88
|
|
Invalid endpoint reference = 89
|
|
Invalid transit network selection = 91
|
|
Too many pending add party requests = 92
|
|
Mandatory information element missing = 96
|
|
Message type non-existent or not implemented = 97
|
|
Information element non existent or not implemented = 99
|
|
Invalid information element contents = 100
|
|
Message not compatible with call state = 101
|
|
Recovery on timer expiry = 102
|
|
Incorrect message length = 104
|
|
Protocol error, unspecified = 111"
|
|
::= 581 -- 0x0245
|
|
|
|
-- deviceNotResponding TRAP-TYPE
|
|
-- ENTERPRISE cabletron
|
|
-- VARIABLES { }
|
|
-- DESCRIPTION
|
|
-- " "
|
|
-- ::= 700 0x02BC
|
|
|
|
|
|
-- deviceConnected TRAP-TYPE
|
|
-- ENTERPRISE cabletron
|
|
-- VARIABLES { }
|
|
-- DESCRIPTION
|
|
-- " "
|
|
-- ::= 701 0x02BD
|
|
|
|
|
|
-- deviceStatusUnknown TRAP-TYPE
|
|
-- ENTERPRISE cabletron
|
|
-- VARIABLES { }
|
|
-- DESCRIPTION
|
|
-- " "
|
|
-- ::= 702 0x02BE
|
|
|
|
deviceDiagnosticMessage TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
DESCRIPTION
|
|
"This trap is generated for diagnostic purposes."
|
|
::= 703 -- 0x02BF
|
|
|
|
|
|
bridgeStatusChanged TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { bdgdeviceStatus }
|
|
DESCRIPTION
|
|
"This trap is generated when the status of the bridge
|
|
changes."
|
|
::= 769 -- 0x0301
|
|
|
|
aquiredDatabaseFull TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
DESCRIPTION
|
|
"This trap is generated when the acquired portion of
|
|
the bridge's filtering database is full."
|
|
::= 770 -- 0x0302
|
|
|
|
boardPortActivate TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ctFpRedundActivePort }
|
|
DESCRIPTION
|
|
"This Trap is generated when Front Panel Redundancy
|
|
changes the active port."
|
|
::= 849 -- 0x0351
|
|
|
|
boardNightVision TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
DESCRIPTION
|
|
"This trap is generated when night vision turns off or
|
|
on. If power to the device is lost, this trap is sent
|
|
with a value of 0, indicating that power has been lost
|
|
but the device is running on 'night vision'. If power
|
|
is not restored within 10 minutes, the device shuts down
|
|
completely. If power is restored in that time frame,
|
|
the trap is sent with a value of 1 indicating as such."
|
|
::= 900 -- 0x384
|
|
|
|
snmpLostContact TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { snmpPollDestination, snmpPollOwner }
|
|
DESCRIPTION
|
|
"A LostContact signifies that a the Cabletron hub has lost
|
|
contact with the destination IP address host/device. This trap
|
|
is only sent at the 'trap-wait' intervals. Note that this trap
|
|
indicates a poll failure, not a threshold failure. Threshold
|
|
alarms are generated independently. The snmpPollDestination
|
|
indicates the lost device."
|
|
::= 1000 -- 0x03E8
|
|
|
|
snmpThresholdTrap TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { snmpOIDDestination, snmpOIDOwner, snmpOIDSequence,
|
|
snmpOIDObject }
|
|
DESCRIPTION
|
|
"This trap signifies that an OID value/threshold comparison
|
|
has failed. The snmpOIDObject specifies which Object Identifier
|
|
and instance (destination IP address, owner IP address, and
|
|
sequence number) was used to trigger the alarm condition. The
|
|
snmpOIDDestination indicates the node address that failed the
|
|
OID poll."
|
|
::= 1001
|
|
|
|
snmpReestabContact TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { snmpPollDestination, snmpPollOwner }
|
|
DESCRIPTION
|
|
"A ReestabContact signifies that a the Cabletron hub has
|
|
reestablished contact with the destination IP address
|
|
host/device. This trap is sent immediately after contact
|
|
has been reestablished."
|
|
::= 1002 -- 0x03EA
|
|
|
|
-- There are a other traps associated with ctBroadcast at 289 and 290.
|
|
|
|
ctBroadcastThresholdReached TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ctBroadcastDesiredBroadcastThreshold,
|
|
ctBroadcastCtlSlotID,
|
|
ctBroadcastCtlInterface}
|
|
DESCRIPTION
|
|
"This trap is generated when the configured
|
|
broadcast threshold on a port is reached and
|
|
will include the slot number and port number
|
|
the threshold was reached on."
|
|
::= 1003 -- 0x03EB
|
|
|
|
ctLecStatus TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { lecRowStatus }
|
|
DESCRIPTION
|
|
"This trap is generated when the operational
|
|
state of the LAN Emulation Client has changed."
|
|
::= 1004 -- 0x03EC
|
|
|
|
fddiPortConnectStateChange TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { fddimibSMTIndex, fddimibPORTIndex,
|
|
fddimibPORTConnectState }
|
|
DESCRIPTION
|
|
"This trap is generated for FDDI port connection state
|
|
changes. The variables are found in IETF FDDI MIB
|
|
RFC-1512."
|
|
::= 1024 -- 0x400
|
|
|
|
fddiSMTMasterPortIncrease TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { fddimibSMTIndex, fddimibSMTMasterCts }
|
|
DESCRIPTION
|
|
"This trap is generated whenever there is an increase in
|
|
the number of SMT master ports."
|
|
::= 1025 -- 0x401
|
|
|
|
fddiSMTMasterPortDecrease TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { fddimibSMTIndex, fddimibSMTMasterCts }
|
|
DESCRIPTION
|
|
"This trap is generated anytime there is a decrease in
|
|
the number of SMT master ports."
|
|
::= 1026 -- 0x402
|
|
|
|
|
|
fddiPortAction TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { fddimibSMTIndex, fddimibPORTIndex,
|
|
fddimibPORTAction }
|
|
DESCRIPTION
|
|
"This trap is generated for every action against a
|
|
FDDI port. The variables are found in IETF FDDI MIB
|
|
RFC-1512."
|
|
::= 1027 -- 0x403
|
|
|
|
fddiPortLerAlarm TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { fddimibSMTIndex, fddimibPORTIndex,
|
|
fddimibPORTLerEstimate }
|
|
DESCRIPTION
|
|
"This trap is generated when the long term link
|
|
error rate, fddimibPORTLerEstimate, crosses the
|
|
fddimibPORTLerAlarm threshold. The variables are
|
|
found in IETF FDDI MIB RFC-1512."
|
|
::= 1028 -- 0x404
|
|
|
|
fddiModuleFNBbypassed TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { chSlotID }
|
|
DESCRIPTION
|
|
"This trap is generated when a FDDI module
|
|
is bypassed on the FNB."
|
|
::= 1030 -- 0x406
|
|
|
|
fddiModuleFNBinserted TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { chSlotID }
|
|
DESCRIPTION
|
|
"This trap is generated when a FDDI module
|
|
is inserted on the FNB."
|
|
::= 1031 -- 0x407
|
|
|
|
fddiMACRMTState TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { fddimibSMTIndex, fddimibMACIndex,
|
|
fddimibMACRMTState }
|
|
DESCRIPTION
|
|
"This trap is generated when there is a
|
|
change in the FDDI ring state. The variables
|
|
are found in IETF FDDI MIB RFC-1512."
|
|
::= 1032 -- 0x408
|
|
|
|
fddiMACCurrentPath TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { fddimibSMTIndex, fddimibMACIndex,
|
|
fddimibMACCurrentPath }
|
|
DESCRIPTION
|
|
"This trap is generated when there is a
|
|
change in the insertion of the MAC to the
|
|
FDDI ring. The variables are found in IETF
|
|
FDDI MIB RFC-1512."
|
|
::= 1033 -- 0x409
|
|
|
|
fddiSMTCFState TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { fddimibSMTIndex, fddimibSMTCFState }
|
|
DESCRIPTION
|
|
"This trap is generated when there is a
|
|
change in the attachment configuration for
|
|
the station or concentrator. The variables
|
|
are found in IETF FDDI MIB RFC-1512."
|
|
::= 1034 -- 0x40A
|
|
|
|
fddiRingTopology TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ctsmtmibRingSmtIndex, ctsmtmibRingMacIndex,
|
|
ctsmtmibRingNodeIndex, ctsmtmibRingMacAddr,
|
|
ctsmtmibRingTopology }
|
|
DESCRIPTION
|
|
"This trap is generated when there is a
|
|
change in the attachment configuration for
|
|
the station or concentrator. It provides
|
|
information additional to fddiSMTCFState,
|
|
twisted ring conditions in particular. The
|
|
variables are found in the Cabletron SMT MIB."
|
|
::= 1035 -- 0x40B
|
|
|
|
fddiMACFrameErrorRatio TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { fddimibSMTIndex, fddimibMACIndex,
|
|
fddimibMACFrameErrorRatio }
|
|
DESCRIPTION
|
|
"This trap is generated when the frame error
|
|
ratio exceeds the frame error threshold,
|
|
fddimibMACFrameErrorThreshold. The variables
|
|
are found in IETF FDDI MIB RFC-1512."
|
|
::= 1036 -- 0x40C
|
|
|
|
fddiMACDuplicateMACAddress TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { fddimibSMTIndex, fddimibMACIndex }
|
|
DESCRIPTION
|
|
"This trap is generated when the SMT detects
|
|
a duplicate MAC address on the ring."
|
|
::= 1037 -- 0x40D
|
|
|
|
--================== The end of the list of FDDI Traps ========================
|
|
|
|
--========================== container traps ==================================
|
|
|
|
contLogicalChangesTrap TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { contTypeLogicalChanges }
|
|
DESCRIPTION
|
|
"This trap is generated when any change occurs
|
|
in the contLogicalEntryTable group of the container MIB."
|
|
::= 1200
|
|
|
|
|
|
contPhysicalChangesTrap TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { contTypePhysicalChanges }
|
|
DESCRIPTION
|
|
"This trap is generated when any change occurs to
|
|
contPhysicalEntryTable group of the container MIB."
|
|
::= 1201
|
|
|
|
--=============================================================================
|
|
|
|
rtrIpEventLogChange TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { nwIpEventTextString }
|
|
DESCRIPTION
|
|
"This trap is generated for changes to IP event log."
|
|
::= 1280 -- 0x500
|
|
|
|
rtrIPXEventLogChange TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { nwIpxEventTextString }
|
|
DESCRIPTION
|
|
"This trap is generated whenever an entry is made to the
|
|
router IPX event log for where nwIpEventSeverity has a
|
|
value of highest(1)."
|
|
::= 1281 -- 0x501
|
|
|
|
rtrDecIVEventLogChange TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { nwDecIVEventTextString }
|
|
DESCRIPTION
|
|
"This trap is generated whenever an entry is made to the
|
|
router Dec Net IV event log."
|
|
::= 1282 -- 0x502
|
|
|
|
rtrAppleEventLogChange TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { nwAtEventTextString }
|
|
DESCRIPTION
|
|
"This trap is generated whenever an entry is made to the
|
|
router Apple Talk event log."
|
|
::= 1283 -- 0x503
|
|
|
|
rtrAppnEventLogChange TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { nwAppnEventTextString }
|
|
DESCRIPTION
|
|
"This trap is generated whenever an entry is made to the
|
|
router APPN event log."
|
|
::= 1284 -- 0x504
|
|
|
|
nwAppnLsUp TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { nwAppnFwdLsName }
|
|
DESCRIPTION
|
|
"When a link station becomes active, a trap is
|
|
generated. nwAppnFwdLsName identifies the link
|
|
station name."
|
|
::= 1285 -- 0x505
|
|
|
|
nwAppnLsDown TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { nwAppnFwdLsName, nwAppnFwdLsAdjCpName,
|
|
nwAppnFwdLsAdjCpType }
|
|
DESCRIPTION
|
|
"When a link station is deactivated, a trap is
|
|
generated. nwAppnFwdLsName identifies the link
|
|
station name, nwAppnFwdLsAdjCpName identifies the
|
|
fully qualified CP name of the adjacent node and
|
|
nwAppnFwdLsAdjCpType is the type of that node."
|
|
::= 1286 -- 0x506
|
|
|
|
-- All traps between 0x578 (1400) and 0x5DB (1499) are reserved
|
|
-- for secure fast switching
|
|
|
|
-- SecureFast Traps [Trap Ids 1400 - 1499 (0578h - 05DBh)]
|
|
|
|
-- SecureFast Traps are by default Disabled. To Enable SecureFast Traps,
|
|
-- the "service.trap" element in the Bindery must be enabled. In addition,
|
|
-- Individual SecureFast Traps can be disabled via the SFPSTrapAPI Mib.
|
|
-- (Disabling a Trap is Persistant, therefore next reboot, the trap will
|
|
-- stay disabled). The SFPSTrap Mib can be used to view the current
|
|
-- OperStatus of the individual traps, as well as how many of each trap
|
|
-- have been sent, and when the last one was sent.
|
|
|
|
-- Below - <h> = Hash Value; <i> = Index Value; <p> = Port
|
|
|
|
|
|
-- Trap #1400 - New User
|
|
--
|
|
-- 1.3.6.1.4.1.52.4.2.4.2.2.3.5.1.1.5.<h>.<i> = [Int] Port Number
|
|
-- 1.3.6.1.4.1.52.4.2.4.2.2.3.5.1.1.7.<h>.<i> = [Str] Node's Mac Address
|
|
|
|
sfpsNewUser TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { sfpsNodeTablePort, sfpsNodeTableBaseAddress }
|
|
DESCRIPTION
|
|
"This trap is generated when a new user enters the SFPS
|
|
fabric."
|
|
::= 1400 -- 0x578
|
|
|
|
|
|
-- Trap #1401 - Directory Violation
|
|
--
|
|
-- 1.3.6.1.4.1.52.4.2.4.2.2.3.15.1.1.1.3.<h>.<i> = [Int] Violation Type
|
|
-- 1.3.6.1.4.1.52.4.2.4.2.2.3.15.1.1.1.6.<h>.<i> = [Str] L2/L3 Address Value
|
|
|
|
sfpsDirectoryViolation TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { sfpsDirViolationType,sfpsDirViolationAOValue }
|
|
DESCRIPTION
|
|
"This trap is generated when one of 6 violation types have occurred.
|
|
1 UserLock
|
|
2 RestrictedPort
|
|
3 IPNotLearned
|
|
4 IPInvalid
|
|
5 RestrictedMobility
|
|
6 UserLockSamePort "
|
|
::= 1401 -- 0x579
|
|
|
|
|
|
-- Trap #1402 - Source Blocked
|
|
--
|
|
-- 1.3.6.1.4.1.52.4.2.4.2.2.14.2.1.1.2.<i> = [Str] Source Mac Address Blocked
|
|
|
|
sfpsSourceBlocked TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { sfpsBlockSourceMAC }
|
|
DESCRIPTION
|
|
"This trap is generated when a user (source MAC address) has
|
|
surpassed the Source Blocker thresholds and is being blocked from
|
|
sending traffic on the network."
|
|
::= 1402 -- 0x57A
|
|
|
|
|
|
-- Trap #1403 - Flood Suppressed
|
|
--
|
|
-- 1.3.6.1.4.1.52.4.2.4.2.2.2.4.1.4.1.1.4.<h>.<i> = [Str] L2/L3 Address Blocked
|
|
|
|
sfpsFloodSurpressed TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { sfpsBlockResolveTableAOValue }
|
|
DESCRIPTION
|
|
"A destination address has been unresolvable past the thresholds
|
|
and is now being flood suppressed (only 1 per X seconds will pass)."
|
|
::= 1403 -- 0x57B
|
|
|
|
|
|
-- Trap #1404 - Port to Standby
|
|
--
|
|
-- 1.3.6.1.4.1.52.4.2.4.2.1.2.1.1.1.1.<p> = [Int] Port Number
|
|
-- 1.3.6.1.4.1.52.4.2.4.2.1.2.1.1.1.5.<p> = [Int] New Port State
|
|
|
|
sfpsPortToStandby TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { sfpsInPortConfigPort, sfpsInPortConfigType }
|
|
DESCRIPTION
|
|
"This trap is generated when a port has entered standby.
|
|
There are different standby states:
|
|
9 STAND_BY (manually set)
|
|
14 STAND_BY_FCL (one way neighbor)
|
|
15 STAND_BY_LOOPED (self originated Hello seen on port)
|
|
16 STAND_BY_RTA (redundant access port is standby/backup "
|
|
::= 1404 -- 0x57C
|
|
|
|
|
|
-- Trap #1405 - Port from Standby
|
|
--
|
|
-- 1.3.6.1.4.1.52.4.2.4.2.1.2.1.1.1.1.<p> = [Int] Port Number
|
|
-- 1.3.6.1.4.1.52.4.2.4.2.1.2.1.1.1.5.<p> = [Int] New Port State
|
|
|
|
sfpsPortFromStandby TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { sfpsInPortConfigPort, sfpsInPortConfigType }
|
|
DESCRIPTION
|
|
"This trap is generated when a port that was in standby is
|
|
now not in standby. Most common is that either a one-way
|
|
neighbor situation is gone or a standby RA port is now primary."
|
|
::= 1405 -- 0x57D
|
|
|
|
-- ======================================================================
|
|
|
|
-- All traps between 0x600 (1536) and 0x6FF (1791) are reserved
|
|
-- for mid level managers.
|
|
|
|
|
|
nmsMapAdded TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { logEventIndex,
|
|
logIndex,
|
|
logTime,
|
|
logDescription }
|
|
DESCRIPTION
|
|
"This trap is generated when the SOS Gateway agent detects
|
|
that a third party NMS has added a new map to its database."
|
|
::= 1536
|
|
|
|
nmsMapDeleted TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { logEventIndex,
|
|
logIndex,
|
|
logTime,
|
|
logDescription }
|
|
DESCRIPTION
|
|
"This trap is generated when the SOS Gateway agent detects
|
|
that a third party NMS has deleted a map from its database."
|
|
::= 1537
|
|
|
|
nmsMapChanged TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { logEventIndex,
|
|
logIndex,
|
|
logTime,
|
|
logDescription }
|
|
DESCRIPTION
|
|
"This trap is generated when the SOS Gateway agent detects
|
|
that a third party NMS has changed an attribute of a map
|
|
in its database."
|
|
::= 1538
|
|
|
|
nmsMapOpened TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { logEventIndex,
|
|
logIndex,
|
|
logTime,
|
|
logDescription }
|
|
DESCRIPTION
|
|
"This trap is generated when the SOS Gateway agent detects
|
|
that a third party NMS has opened a map."
|
|
::= 1539
|
|
|
|
nmsMapClosed TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { logEventIndex,
|
|
logIndex,
|
|
logTime,
|
|
logDescription }
|
|
DESCRIPTION
|
|
"This trap is generated when the SOS Gateway agent detects
|
|
that a third party NMS has closed a map."
|
|
::= 1540
|
|
|
|
nmsElementAdded TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { logEventIndex,
|
|
logIndex,
|
|
logTime,
|
|
logDescription }
|
|
DESCRIPTION
|
|
"This trap is generated when the SOS Gateway agent detects
|
|
that a third party NMS has added a new element to its database."
|
|
::= 1541
|
|
|
|
nmsElementDeleted TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { logEventIndex,
|
|
logIndex,
|
|
logTime,
|
|
logDescription }
|
|
DESCRIPTION
|
|
"This trap is generated when the SOS Gateway agent detects
|
|
that a third party NMS has deleted an element from its
|
|
database."
|
|
::= 1542
|
|
|
|
nmsElementChanged TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { logEventIndex,
|
|
logIndex,
|
|
logTime,
|
|
logDescription }
|
|
DESCRIPTION
|
|
"This trap is generated when the SOS Gateway agent detects
|
|
that a third party NMS has changed an attribute of an element
|
|
in its database."
|
|
::= 1543
|
|
|
|
nmsSymbolAdded TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { logEventIndex,
|
|
logIndex,
|
|
logTime,
|
|
logDescription }
|
|
DESCRIPTION
|
|
"This trap is generated when the SOS Gateway agent detects
|
|
that a third party NMS has added a new symbol to its database."
|
|
::= 1544
|
|
|
|
nmsSymbolDeleted TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { logEventIndex,
|
|
logIndex,
|
|
logTime,
|
|
logDescription }
|
|
DESCRIPTION
|
|
"This trap is generated when the SOS Gateway agent detects
|
|
that a third party NMS has deleted a symbol from its database."
|
|
::= 1545
|
|
|
|
nmsSymbolChanged TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { logEventIndex,
|
|
logIndex,
|
|
logTime,
|
|
logDescription }
|
|
DESCRIPTION
|
|
"This trap is generated when the SOS Gateway agent detects
|
|
that a third party NMS has changed an attribute of a symbol
|
|
in its database."
|
|
::= 1546
|
|
|
|
-- ======================================================================
|
|
|
|
-- All traps between 0x708 (1800) and 0x76C (1900) are reserved
|
|
-- for the 5 Slot Work Group chassis.
|
|
|
|
wgPsInstalled TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ctChasPowerSupplyNum,
|
|
ctChasPowerSupplyType }
|
|
DESCRIPTION
|
|
"This trap is generated when the device detects that the
|
|
power supply has been installed."
|
|
::= 1800
|
|
|
|
wgPsRemoved TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ctChasPowerSupplyNum }
|
|
DESCRIPTION
|
|
"This trap is generated when the device detects that the
|
|
power supply has been removed."
|
|
::= 1801
|
|
|
|
wgPsNormal TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ctChasPowerSupplyNum }
|
|
DESCRIPTION
|
|
"This trap is generated when the device detects that the power
|
|
supply has returned to normal."
|
|
::= 1802
|
|
|
|
wgPsFail TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ctChasPowerSupplyNum }
|
|
DESCRIPTION
|
|
"This trap is generated when the device detects that the power
|
|
supply has failed."
|
|
::= 1803
|
|
|
|
wgPsRedundant TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ctChasPowerSupplyNum }
|
|
DESCRIPTION
|
|
"This trap is generated when the device detects that the power
|
|
supply is in the redundant state."
|
|
::= 1804
|
|
|
|
|
|
wgPsNotRedundant TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ctChasPowerSupplyNum }
|
|
DESCRIPTION
|
|
"This trap is generated when the device detects that the power
|
|
supply is not in the redundant state."
|
|
::= 1805
|
|
|
|
wgBoardInserted TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { contPhysicalEntryID }
|
|
DESCRIPTION
|
|
"This trap is generated when a module is inserted."
|
|
::= 1806
|
|
|
|
wgBoardRemoved TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { contPhysicalEntryID }
|
|
DESCRIPTION
|
|
"This trap is generated when a module is removed."
|
|
::= 1807
|
|
|
|
|
|
-- ======================================================================
|
|
|
|
aPCLineFail TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
DESCRIPTION
|
|
"This trap is generated in the event of an AC
|
|
utility line failure"
|
|
::= 4353 -- 0x1101
|
|
|
|
|
|
aPCLineFailRecovery TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
DESCRIPTION
|
|
"This trap is generated when the UPS switches back
|
|
to line, and only if the aPCLineFail trap was issued
|
|
first"
|
|
::= 4354 -- 0x1102
|
|
|
|
|
|
aPCLowBattery TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
DESCRIPTION
|
|
"This trap is generated in the event that the UPS'
|
|
battery is found to be low"
|
|
::= 4355 -- 0x1103
|
|
|
|
|
|
aPCLowBatteryRecovery TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
DESCRIPTION
|
|
"This trap is generated when the UPS' battery has
|
|
charged above the low-battery point, and only if the
|
|
aPCLowBattery trap was issued first"
|
|
::= 4356 -- 0x1104
|
|
|
|
|
|
aPCAbnormalCondition TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
DESCRIPTION
|
|
"This trap is generated in the event that the UPS
|
|
has entered an abnormal condition, such as an
|
|
overload or trip on low battery. This trap is also
|
|
sent, when the UPS is first turned on."
|
|
::= 4357 -- 0x1105
|
|
|
|
|
|
aPCAbnormConditionRecovery TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
DESCRIPTION
|
|
"This trap is generated when the UPS has recovered
|
|
from an abnormal condition, and only if the
|
|
aPCAbnormalCondition trap was issued first"
|
|
::= 4358 -- 0x1106
|
|
|
|
|
|
aPCShuttingDown TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
DESCRIPTION
|
|
"This trap is generated in the event that the UPS
|
|
has been ordered to shut itself, or the load, off
|
|
over the serial line."
|
|
::= 4359 -- 0x1107
|
|
|
|
-- =====================================================================
|
|
-- The range of trap IDs from 5001 to 5400 decimal are reserved
|
|
-- for WAN traps.
|
|
-- ======================================================================
|
|
-- The range of trap IDs from 11001 to 11999 decimal are reserved
|
|
-- for MMAC+ traps.
|
|
|
|
emTermOverVoltage TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
DESCRIPTION
|
|
"This trap is generated when the term power bus is over voltage."
|
|
::= 11001
|
|
|
|
emTermUnderVoltage TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
DESCRIPTION
|
|
"This trap is generated when the term power bus is under voltage."
|
|
::= 11002
|
|
|
|
emTermNormalVoltage TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
DESCRIPTION
|
|
"This trap is generated when the term power bus is at an acceptable
|
|
voltage. It will only be sent out after a trap was sent to say that
|
|
the term voltage was under or over."
|
|
::= 11003
|
|
|
|
chHotTemp TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
DESCRIPTION
|
|
"This trap is generated because the chassis is hot."
|
|
::= 11004
|
|
|
|
chWarmTemp TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
DESCRIPTION
|
|
"This trap is generated because the chassis is warm."
|
|
::= 11005
|
|
|
|
chCoolTemp TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
DESCRIPTION
|
|
"This trap is generated because the chassis is cool."
|
|
::= 11006
|
|
|
|
chColdTemp TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
DESCRIPTION
|
|
"This trap is generated because the chassis is cold."
|
|
::= 11007
|
|
|
|
chTempOK TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
DESCRIPTION
|
|
"This trap is generated because the chassis has returned to normal
|
|
after being warm, hot, cool or cold."
|
|
::= 11008
|
|
|
|
chTempSensorBroken TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
DESCRIPTION
|
|
"This trap is generated when the chassis's temperature sensor is
|
|
broken."
|
|
::= 11009
|
|
|
|
chHumidityStaticRisk TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
DESCRIPTION
|
|
"This trap is generated when the chassis determines there is a
|
|
humidity static risk."
|
|
::= 11010
|
|
|
|
chHumidityNormal TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
DESCRIPTION
|
|
"This trap is generated when the chassis determines the humidity
|
|
has returned to normal after being moist or static risk."
|
|
::= 11011
|
|
|
|
chHumidityMoist TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
DESCRIPTION
|
|
"This trap is generated when the chassis determines there is a
|
|
humidity moist risk."
|
|
::= 11012
|
|
|
|
chHumiditySensorBroken TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
DESCRIPTION
|
|
"This trap is generated when the chassis determines the humidity
|
|
sensor is broken."
|
|
::= 11013
|
|
|
|
chMod1INBInstalled TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
DESCRIPTION
|
|
"This trap is generated when the INV termination has been installed
|
|
for module 1."
|
|
::= 11014
|
|
|
|
chMod1INBFaulty TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
DESCRIPTION
|
|
"This trap is generated when the INV termination is faulty for
|
|
module 1."
|
|
::= 11015
|
|
|
|
chMod1INBRemoved TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
DESCRIPTION
|
|
"This trap is generated when the INV termination has been removed for
|
|
module 1."
|
|
::= 11016
|
|
|
|
chMod1INBNormal TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
DESCRIPTION
|
|
"This trap is generated when the INV termination (module 1) has
|
|
returned to normal after already sending a trap to say it was faulty."
|
|
::= 11017
|
|
|
|
chMod2INBInstalled TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
DESCRIPTION
|
|
"This trap is generated when the INV termination has been installed
|
|
for module 2."
|
|
::= 11018
|
|
|
|
chMod2INBFaulty TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
DESCRIPTION
|
|
"This trap is generated when the INV termination is faulty for
|
|
module 2."
|
|
::= 11019
|
|
|
|
chMod2INBRemoved TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
DESCRIPTION
|
|
"This trap is generated when the INV termination has been removed for
|
|
module 2."
|
|
::= 11020
|
|
|
|
chMod2INBNormal TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
DESCRIPTION
|
|
"This trap is generated when the INV termination (module 2) has
|
|
returned to normal after already sending a trap to say it was faulty."
|
|
::= 11021
|
|
|
|
emFanFailure TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
DESCRIPTION
|
|
"This trap is generated when the chassis detects a fan failure."
|
|
::= 11022
|
|
|
|
boardHotTempShutdown TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because a board is hot and the board has shut
|
|
itself down."
|
|
::= 11023
|
|
|
|
boardWarmTemp TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because a board is warm."
|
|
::= 11024
|
|
|
|
boardCoolTemp TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because a board is cool."
|
|
::= 11025
|
|
|
|
boardColdTemp TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because a board is cold."
|
|
::= 11026
|
|
|
|
boardTempOK TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because a board has returned to normal after
|
|
being warm or hot."
|
|
::= 11027
|
|
|
|
boardTempSensorBroken TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated when the board's temperature sensor is
|
|
broken."
|
|
::= 11028
|
|
|
|
boardTempHotNoAdmin TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because a board is hot."
|
|
::= 11029
|
|
|
|
boardRelWarmTemp TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because a board's relative temp is warm."
|
|
::= 11030
|
|
|
|
boardRelTempOK TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because a board's relative temp has returned
|
|
to normal after being warm or hot."
|
|
::= 11031
|
|
|
|
boardRelTempHotNoAdmin TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because a board's relative temp is hot but it
|
|
cannot shutdown. It will need to be turned off remotely."
|
|
::= 11032
|
|
|
|
boardRelTempHotShutdown TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated when the board's relative temperature is hot
|
|
and is being powered off."
|
|
::= 11033
|
|
|
|
boardRelWarmTempMaxFans TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because a board's relative temp is warm. The
|
|
fans are on MAX."
|
|
::= 11034
|
|
|
|
boardRelTempOKMaxFans TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because a board's relative temp has returned
|
|
to normal after being warm or hot. The fans are on MAX."
|
|
::= 11035
|
|
|
|
boardRelTempHotNoAdminMaxFans TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because a board's relative temp is hot but it
|
|
cannot shutdown. It will need to be turned off remotely. The fans are
|
|
on MAX."
|
|
::= 11036
|
|
|
|
boardRelTempHotShutdownMaxFans TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated when the board's relative temperature is hot
|
|
and is being powered off. The fans are on MAX."
|
|
::= 11037
|
|
|
|
boardInputVoltageOverMax TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because a boards input voltage is over max."
|
|
::= 11038
|
|
|
|
boardInputVoltageUnderMin TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because a boards input voltage is under
|
|
minimum."
|
|
::= 11039
|
|
|
|
boardInputVoltageOK TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because a board input voltage has returned to
|
|
normal after being over or under."
|
|
::= 11040
|
|
|
|
boardOutputVoltageOverMax TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because a board output voltage is over MAX."
|
|
::= 11041
|
|
|
|
boardOutputVoltageUnderMin TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because a board output voltage is under MIN."
|
|
::= 11042
|
|
|
|
boardOutputVoltageOK TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because a board output voltage has returned to
|
|
normal after being over or under."
|
|
::= 11043
|
|
|
|
boardAuxVoltageOverMax TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because a boards auxiliary voltage is over
|
|
MAX."
|
|
::= 11044
|
|
|
|
boardAuxVoltageUnderMin TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because a board auxiliary voltage is under
|
|
MIN."
|
|
::= 11045
|
|
|
|
boardAuxVoltageOK TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because a board auxiliary voltage has returned
|
|
to normal after being over or under."
|
|
::= 11046
|
|
|
|
boardInputCurrentOverMaxShutdown TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because a board input current is
|
|
over MAX. The power supply has therefore been shutdown."
|
|
::= 11047
|
|
|
|
boardOutputCurrentOverMaxShutdown TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because a boards output current is
|
|
over MAX. The power supply has therefore been shutdown."
|
|
::= 11048
|
|
|
|
boardInputCurrentOverMax TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because a board input current is
|
|
over MAX. The ability of the power supply to turn itself off has been
|
|
disabled therefore outside intervention is needed."
|
|
::= 11049
|
|
|
|
boardOutputCurrentOverMax TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because a board output current is
|
|
over MAX. The ability of the power supply to turn itself off has been
|
|
disabled therefore outside intervention is needed."
|
|
::= 11050
|
|
|
|
boardRemotePowerOff TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because the board is being powered
|
|
off due to outside intervention."
|
|
::= 11051
|
|
|
|
boardRemotePowerOn TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because the board is being powered
|
|
on due to outside intervention."
|
|
::= 11052
|
|
|
|
boardRemotePowerReset TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because the board is being reset due to
|
|
outside intervention."
|
|
::= 11053
|
|
|
|
boardPowerOn TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because the board power has been powered on."
|
|
::= 11054
|
|
|
|
boardPowerOff TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because the board power has been powered off."
|
|
::= 11055
|
|
|
|
boardPowerReset TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because the board has been reset."
|
|
::= 11056
|
|
|
|
boardRemOverCurrentShutdown TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because the board has been shutdown remotely
|
|
due to being over current."
|
|
::= 11057
|
|
|
|
boardRemPowerConservationShutdown TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because the board has been shutdown remotely
|
|
due to power conservation."
|
|
::= 11058
|
|
|
|
boardRemTemperatureShutdown TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because the board has been shutdown remotely
|
|
due to it's temperature."
|
|
::= 11059
|
|
|
|
boardReqFPDisableDCDC TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because the board has had an unauthorized
|
|
front panel disable."
|
|
::= 11060
|
|
|
|
boardFPDisableDCDC TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because the board has been disabled through
|
|
the front panel."
|
|
::= 11061
|
|
|
|
boardReqFPEnableDCDC TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because the board has had an unauthorized
|
|
front panel enable."
|
|
::= 11062
|
|
|
|
boardFPEnableDCDC TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because the board has been enabled through the
|
|
front panel."
|
|
::= 11063
|
|
|
|
boardReqFPResetDCDC TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because the board has had an unauthorized
|
|
front panel reset."
|
|
::= 11064
|
|
|
|
boardFPResetDCDC TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because the board has been reset through the
|
|
front panel."
|
|
::= 11065
|
|
|
|
boardADConvertorFailure TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because the board's A/D converter is broken."
|
|
::= 11066
|
|
|
|
boardPICFailure TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because of a board PIC failure."
|
|
::= 11067
|
|
|
|
boardPICOk TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because the board PIC is now OK.
|
|
This trap will only be sent AFTER a PIC failure trap has been
|
|
generated."
|
|
::= 11068
|
|
|
|
boardLLAPDupAddress TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated when the board LLAP address already exists
|
|
in this chassis."
|
|
::= 11069
|
|
|
|
boardMailboxFailure TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because of a board mailbox failure."
|
|
::= 11070
|
|
|
|
boardMailboxOK TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because the board mailbox is now OK."
|
|
::= 11071
|
|
|
|
psACHotTempShutdown TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an AC power supply is hot and the
|
|
power supply has shut itself down."
|
|
::= 11072
|
|
|
|
psACWarmTemp TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an AC power supply is warm."
|
|
::= 11073
|
|
|
|
psACTempOK TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an AC power supply has returned
|
|
to normal after being warm or hot."
|
|
::= 11074
|
|
|
|
psACTempOKNoAdmin TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an AC power supply has returned
|
|
to normal after being shutdown remotely. It will need to be powerOn
|
|
remotely."
|
|
::= 11075
|
|
|
|
psACTempSensorBroken TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated when the AC power supply's temperature
|
|
sensor is broken."
|
|
::= 11076
|
|
|
|
psACTempHot TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an AC power supply is hot."
|
|
::= 11077
|
|
|
|
psACInputVoltageOverMax TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an AC power supply input voltage
|
|
is over max."
|
|
::= 11078
|
|
|
|
psACInputVoltageUnderMin TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an AC power supply input voltage
|
|
is under minimum."
|
|
::= 11079
|
|
|
|
psACInputVoltageOK TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an AC power supply input voltage has
|
|
returned to normal after being over or under."
|
|
::= 11080
|
|
|
|
psACSystemVoltageOverMax TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an AC power supply system voltage is
|
|
over MAX."
|
|
::= 11081
|
|
|
|
psACSystemVoltageUnderMin TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an AC power supply system voltage is
|
|
under MIN."
|
|
::= 11082
|
|
|
|
psACSystemVoltageOK TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an AC power supply system voltage has
|
|
returned to normal after being over or under."
|
|
::= 11083
|
|
|
|
psACLogicVoltageOverMax TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an AC power supply logic voltage is
|
|
over MAX."
|
|
::= 11084
|
|
|
|
psACLogicVoltageUnderMin TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an AC power supply logic voltage is
|
|
under MIN."
|
|
::= 11085
|
|
|
|
psACLogicVoltageOK TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an AC power supply logic voltage has
|
|
returned to normal after being over or under."
|
|
::= 11086
|
|
|
|
psACTermVoltageOverMax TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an AC power supply term voltage is
|
|
over MAX."
|
|
::= 11087
|
|
|
|
psACTermVoltageUnderMin TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an AC power supply term voltage is
|
|
under MIN."
|
|
::= 11088
|
|
|
|
psACTermVoltageOK TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an AC power supply term voltage has
|
|
returned to normal after being over or under."
|
|
::= 11089
|
|
|
|
psACLogicSenseCurrentOverMax TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an AC power supply logic current is
|
|
over MAX. The ability of the power supply to turn itself off has been
|
|
disabled therefore outside intervention is needed."
|
|
::= 11090
|
|
|
|
psACTermSenseCurrentOverMax TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an AC power supply term current is
|
|
over MAX. The ability of the power supply to turn itself off has been
|
|
disabled therefore outside intervention is needed."
|
|
::= 11091
|
|
|
|
psACInputCurrentOverMaxShutdown TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an AC power supply input current is
|
|
over MAX. The power supply has therefore been shutdown."
|
|
::= 11092
|
|
|
|
psACSystemCurrentOverMaxShutdown TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an AC power supply system current is
|
|
over MAX. The power supply has therefore been shutdown."
|
|
::= 11093
|
|
|
|
psACLogicCurrentOverMaxShutdown TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an AC power supply logic current is
|
|
over MAX. The power supply has therefore been shutdown."
|
|
::= 11094
|
|
|
|
psACTermCurrentOverMaxShutdown TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an AC power supply term current is
|
|
over MAX. The power supply has therefore been shutdown."
|
|
::= 11095
|
|
|
|
psACLogicSenseCurrentOverMaxShutdown TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an AC power supply logic sense current
|
|
is over MAX. The power supply has therefore been shutdown."
|
|
::= 11096
|
|
|
|
psACTermSenseCurrentOverMaxShutdown TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an AC power supply term sense current
|
|
is over MAX. The power supply has therefore been shutdown."
|
|
::= 11097
|
|
|
|
psACInputCurrentOverMax TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an AC power supply input current is
|
|
over MAX. The ability of the power supply to turn itself off has been
|
|
disabled therefore outside intervention is needed."
|
|
::= 11098
|
|
|
|
psACSystemCurrentOverMax TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an AC power supply system current is
|
|
over MAX. The ability of the power supply to turn itself off has been
|
|
disabled therefore outside intervention is needed."
|
|
::= 11099
|
|
|
|
psACLogicCurrentOverMax TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an AC power supply logic current is
|
|
over MAX. The ability of the power supply to turn itself off has been
|
|
disabled therefore outside intervention is needed."
|
|
::= 11100
|
|
|
|
psACTermCurrentOverMax TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an AC power supply term current is
|
|
over MAX. The ability of the power supply to turn itself off has been
|
|
disabled therefore outside intervention is needed."
|
|
::= 11101
|
|
|
|
psACRemotePowerOff TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because the AC power supply is being powered
|
|
off due to outside intervention."
|
|
::= 11102
|
|
|
|
psACSystemPowerOn TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because the AC power supply system power has
|
|
been powered on."
|
|
::= 11103
|
|
|
|
psACSystemPowerOff TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because the AC power supply system power has
|
|
been powered off."
|
|
::= 11104
|
|
|
|
psACLogicPowerOn TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because the AC power supply logic power has
|
|
been powered on."
|
|
::= 11105
|
|
|
|
psACLogicPowerOff TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because the AC power supply logic power has
|
|
been powered off."
|
|
::= 11106
|
|
|
|
psACTermPowerOn TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because the AC power supply term power has
|
|
been powered on."
|
|
::= 11107
|
|
|
|
psACTermPowerOff TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because the AC power supply term power has
|
|
been powered off."
|
|
::= 11108
|
|
|
|
psACRemOverCurrentShutdown TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because the AC power supply has been shutdown
|
|
remotely due to being over current."
|
|
::= 11109
|
|
|
|
psACRemPowerConservationShutdown TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because the AC power supply has been shutdown
|
|
remotely due to power conservation."
|
|
::= 11110
|
|
|
|
psACADConvertorFailure TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because the AC power supply A/D converter
|
|
is broken."
|
|
::= 11111
|
|
|
|
psACPICFailure TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because of an AC power supply PIC failure."
|
|
::= 11112
|
|
|
|
psACPICOk TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because the AC power supply PIC is now OK.
|
|
This trap will only be sent AFTER a PIC failure trap has been
|
|
generated."
|
|
::= 11113
|
|
|
|
psACLLAPDupAddress TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated when the AC power supply LLAP address already
|
|
exists in this chassis."
|
|
::= 11114
|
|
|
|
psACFanFailure TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because of an AC power supply fan failure."
|
|
::= 11115
|
|
|
|
psACFanOK TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because the AC power supply fan is now OK.
|
|
This trap will only be sent AFTER a fan failure trap has been
|
|
generated."
|
|
::= 11116
|
|
|
|
psDCHotTempShutdown TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an DC power supply is hot and the
|
|
power supply has shut itself down."
|
|
::= 11117
|
|
|
|
psDCWarmTemp TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an DC power supply is warm."
|
|
::= 11118
|
|
|
|
psDCTempOK TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an DC power supply has returned
|
|
to normal after being warm or hot."
|
|
::= 11119
|
|
|
|
psDCTempOKNoAdmin TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an DC power supply has returned
|
|
to normal after being shutdown remotely. It will need to be powerOn
|
|
remotely."
|
|
::= 11120
|
|
|
|
psDCTempSensorBroken TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated when the DC power supply's temperature
|
|
sensor is broken."
|
|
::= 11121
|
|
|
|
psDCTempHot TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an DC power supply is hot."
|
|
::= 11122
|
|
|
|
psDCInputVoltageOverMax TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an DC power supply input voltage
|
|
is over max."
|
|
::= 11123
|
|
|
|
psDCInputVoltageUnderMin TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an DC power supply input voltage
|
|
is under minimum."
|
|
::= 11124
|
|
|
|
psDCInputVoltageOK TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an DC power supply input voltage has
|
|
returned to normal after being over or under."
|
|
::= 11125
|
|
|
|
psDCSystemVoltageOverMax TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an DC power supply system voltage is
|
|
over MAX."
|
|
::= 11126
|
|
|
|
psDCSystemVoltageUnderMin TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an DC power supply system voltage is
|
|
under MIN."
|
|
::= 11127
|
|
|
|
psDCSystemVoltageOK TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an DC power supply system voltage has
|
|
returned to normal after being over or under."
|
|
::= 11128
|
|
|
|
psDCLogicVoltageOverMax TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an DC power supply logic voltage is
|
|
over MAX."
|
|
::= 11129
|
|
|
|
psDCLogicVoltageUnderMin TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an DC power supply logic voltage is
|
|
under MIN."
|
|
::= 11130
|
|
|
|
psDCLogicVoltageOK TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an DC power supply logic voltage has
|
|
returned to normal after being over or under."
|
|
::= 11131
|
|
|
|
psDCTermVoltageOverMax TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an DC power supply term voltage is
|
|
over MAX."
|
|
::= 11132
|
|
|
|
psDCTermVoltageUnderMin TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an DC power supply term voltage is
|
|
under MIN."
|
|
::= 11133
|
|
|
|
psDCTermVoltageOK TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an DC power supply term voltage has
|
|
returned to normal after being over or under."
|
|
::= 11134
|
|
|
|
psDCLogicSenseCurrentOverMax TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an DC power supply logic current is
|
|
over MAX. The ability of the power supply to turn itself off has been
|
|
disabled therefore outside intervention is needed."
|
|
::= 11135
|
|
|
|
psDCTermSenseCurrentOverMax TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an DC power supply term current is
|
|
over MAX. The ability of the power supply to turn itself off has been
|
|
disabled therefore outside intervention is needed."
|
|
::= 11136
|
|
|
|
psDCInputCurrentOverMaxShutdown TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an DC power supply input current is
|
|
over MAX. The power supply has therefore been shutdown."
|
|
::= 11137
|
|
|
|
psDCSystemCurrentOverMaxShutdown TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an DC power supply system current is
|
|
over MAX. The power supply has therefore been shutdown."
|
|
::= 11138
|
|
|
|
psDCLogicCurrentOverMaxShutdown TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an DC power supply logic current is
|
|
over MAX. The power supply has therefore been shutdown."
|
|
::= 11139
|
|
|
|
psDCTermCurrentOverMaxShutdown TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an DC power supply term current is
|
|
over MAX. The power supply has therefore been shutdown."
|
|
::= 11140
|
|
|
|
psDCLogicSenseCurrentOverMaxShutdown TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an DC power supply logic sense current
|
|
is over MAX. The power supply has therefore been shutdown."
|
|
::= 11141
|
|
|
|
psDCTermSenseCurrentOverMaxShutdown TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an DC power supply term sense current
|
|
is over MAX. The power supply has therefore been shutdown."
|
|
::= 11142
|
|
|
|
psDCInputCurrentOverMax TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an DC power supply input current is
|
|
over MAX. The ability of the power supply to turn itself off has been
|
|
disabled therefore outside intervention is needed."
|
|
::= 11143
|
|
|
|
psDCSystemCurrentOverMax TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an DC power supply system current is
|
|
over MAX. The ability of the power supply to turn itself off has been
|
|
disabled therefore outside intervention is needed."
|
|
::= 11144
|
|
|
|
psDCLogicCurrentOverMax TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an DC power supply logic current is
|
|
over MAX. The ability of the power supply to turn itself off has been
|
|
disabled therefore outside intervention is needed."
|
|
::= 11145
|
|
|
|
psDCTermCurrentOverMax TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because an DC power supply term current is
|
|
over MAX. The ability of the power supply to turn itself off has been
|
|
disabled therefore outside intervention is needed."
|
|
::= 11146
|
|
|
|
psDCRemotePowerOff TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because the DC power supply is being powered
|
|
off due to outside intervention."
|
|
::= 11147
|
|
|
|
psDCSystemPowerOn TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because the DC power supply system power has
|
|
been powered on."
|
|
::= 11148
|
|
|
|
psDCSystemPowerOff TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because the DC power supply system power has
|
|
been powered off."
|
|
::= 11149
|
|
|
|
psDCLogicPowerOn TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because the DC power supply logic power has
|
|
been powered on."
|
|
::= 11150
|
|
|
|
psDCLogicPowerOff TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because the DC power supply logic power has
|
|
been powered off."
|
|
::= 11151
|
|
|
|
psDCTermPowerOn TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because the DC power supply term power has
|
|
been powered on."
|
|
::= 11152
|
|
|
|
psDCTermPowerOff TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because the DC power supply term power has
|
|
been powered off."
|
|
::= 11153
|
|
|
|
psDCRemOverCurrentShutdown TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because the DC power supply has been shutdown
|
|
remotely due to being over current."
|
|
::= 11154
|
|
|
|
psDCRemPowerConservationShutdown TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because the DC power supply has been shutdown
|
|
remotely due to power conservation."
|
|
::= 11155
|
|
|
|
psDCADConvertorFailure TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because the DC power supply A/D converter
|
|
is broken."
|
|
::= 11156
|
|
|
|
psADPICFailure TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because of an DC power supply PIC failure."
|
|
::= 11157
|
|
|
|
psADPICOk TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because the DC power supply PIC is now OK.
|
|
This trap will only be sent AFTER a PIC failure trap has been
|
|
generated."
|
|
::= 11158
|
|
|
|
psADLLAPDupAddress TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated when the DC power supply LLAP address already
|
|
exists in this chassis."
|
|
::= 11159
|
|
|
|
psADFanFailure TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because of an DC power supply fan failure."
|
|
::= 11160
|
|
|
|
psDCFanOK TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated because the DC power supply fan is now OK.
|
|
This trap will only be sent AFTER a fan failure trap has been
|
|
generated."
|
|
::= 11161
|
|
|
|
psADConvertorFailure TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotID }
|
|
DESCRIPTION
|
|
"This trap is generated because the power supply A/D converter
|
|
is broken."
|
|
::= 11162
|
|
|
|
psPicFailure TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotID }
|
|
DESCRIPTION
|
|
"This trap is generated because of a power supply PIC failure."
|
|
::= 11163
|
|
|
|
psPICok TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotID }
|
|
DESCRIPTION
|
|
"This trap is generated because the power supply PIC is now OK.
|
|
This trap will only be sent AFTER a PIC failure trap has been
|
|
generated."
|
|
::= 11164
|
|
|
|
psLLAPDupAddress TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotID }
|
|
DESCRIPTION
|
|
"This trap is generated when the power supply LLAP address already
|
|
exists in this chassis."
|
|
::= 11165
|
|
|
|
chEnvAmbientTempChanges TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { chEnvAmbientStatus, chEnvAmbientTemp }
|
|
DESCRIPTION
|
|
"This trap is generated for each and every time the chassis
|
|
ambient temperature crosses over a threshold value
|
|
of either one of the chassis set thresholds chEnvAmbientHot,
|
|
chEnvAmbientWarm, chEnvAmbientCool, or chEnvAmbientCold
|
|
to another. This trap is also sent when the chassis temperature
|
|
sensor is detected to be broken or not supported."
|
|
::= 11166
|
|
|
|
chEnvHumidityChanges TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { chEnvHumidityStatus, chEnvHumidity }
|
|
DESCRIPTION
|
|
"This trap is generated for each and every time the chassis
|
|
humidity crosses a threshold value of either chEnvHumidityMoist,
|
|
or chEnvHumidityDry, or when the humidity sensor is detected to
|
|
be broken or not supported."
|
|
::= 11167
|
|
|
|
boardEnvTempChanges TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardEnvSlotID, boardEnvTemp, boardEnvTempStatus }
|
|
DESCRIPTION
|
|
"This trap is generated for each and every time the board
|
|
temperature crosses over a threshold value of either
|
|
one of the board set thresholds boardEnvTempHot,
|
|
boardEnvTempWarm, boardEnvTempCool, or boardEnvTempCold
|
|
to another. This trap is also sent when the board temperature
|
|
sensor is detected to be broken or not supported."
|
|
::= 11168
|
|
|
|
boardEnvTempRelChanges TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardEnvSlotID, boardEnvTempRelStatus,
|
|
boardEnvTemp, chEnvAmbientTemp }
|
|
DESCRIPTION
|
|
"This trap is generated for each and every time the board
|
|
temperature relative to the chassis ambient temperature
|
|
crosses a threshold value of either boardEnvTempRelHot,
|
|
or boardEnvTempRelWarm. This trap is also sent when either
|
|
temperature sensor located on the board or on the chassis
|
|
is detected to be broken or not supported."
|
|
::= 11169
|
|
|
|
boardEnvTempMaxFanRelChanges TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardEnvSlotID, boardEnvTempRelStatus,
|
|
boardEnvTemp, chEnvAmbientTemp }
|
|
DESCRIPTION
|
|
"This trap is generated for each and every time the board
|
|
temperature relative to the chassis ambient temperature
|
|
crosses a threshold value of either boardEnvTempMaxFanRelHot,
|
|
or boardEnvTempMaxFanRelWarm when all fans in the chassis are
|
|
operating at there maximum speed. This trap is also sent when
|
|
either temperature sensor located on the board or on the chassis
|
|
is detected to be broken or not supported."
|
|
::= 11170
|
|
|
|
chPowerMainVoltageChanges TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { chPowerMainVoltageStatus, chPowerMainVoltage }
|
|
DESCRIPTION
|
|
"This trap is generated for each and every time the chassis
|
|
main voltage rail deviates and causes the chPowerMainVoltageStatus
|
|
to switch state from powerOK(1), overCurrent(2), overVoltage(3),
|
|
or underVoltage(4) to another."
|
|
::= 11171
|
|
|
|
chPowerDiagVoltageChanges TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { chPowerDiagVoltageStatus, chPowerDiagVoltage }
|
|
DESCRIPTION
|
|
"This trap is generated for each and every time the chassis
|
|
diag voltage deviates and causes the chPowerDiagVoltageStatus
|
|
to switch state from powerOK(1), overCurrent(2), overVoltage(3),
|
|
or underVoltage(4) to another."
|
|
::= 11172
|
|
|
|
termPowerVoltageChanges TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { termPowerStatus, termPowerVoltage }
|
|
DESCRIPTION
|
|
"This trap is generated for each and every time the module's
|
|
termination unit changes state and causes the termPowerStatus
|
|
to switch from any states to either powerOK(1), overVoltage(3), or
|
|
underVolatge(4) state."
|
|
::= 11173
|
|
|
|
boardPowerVoltageChanges TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotID, boardPowerID,
|
|
boardPowerStatus, boardPowerVoltage }
|
|
DESCRIPTION
|
|
"This trap is generated for each and every time the module's
|
|
power line voltage deviates and causes the boardPowerStatus
|
|
to switch from any states to either powerOK(1), overVoltage(4),
|
|
or underVoltage(5) state."
|
|
::= 11174
|
|
|
|
termPowerModule1Changes TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { termPowerModule1Status }
|
|
DESCRIPTION
|
|
"This trap is generated for each and every time the module's
|
|
front panel button changes state and causes the termPowerModule1Status
|
|
to switch state from either one of normal(1), iNBaFault(2),
|
|
iNBbFault(3), fault(4), termModuleNotInstalled(5) to another."
|
|
::= 11175
|
|
|
|
termPowerModule2Changes TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { termPowerModule2Status }
|
|
DESCRIPTION
|
|
"This trap is generated for each and every time the module's
|
|
front panel button changes state and causes the termPowerModule2Status
|
|
to switch state from either one of normal(1), iNBaFault(2),
|
|
iNBbFault(3), fault(4), termModuleNotInstalled(5) to another."
|
|
::= 11176
|
|
|
|
chEnvFanChanges TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { chEnvFanID, chEnvFanStatus, chEnvFanSpeed }
|
|
DESCRIPTION
|
|
"This trap is generated for each and every time the chassis
|
|
fan changes over its status from either one value unknown(1),
|
|
normal(2), testing(3), slow(4), inoperative(5), or off(6)
|
|
to another."
|
|
::= 11177
|
|
|
|
boardPowerCurrentChanges TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotID, boardPowerID,
|
|
boardPowerStatus, boardPowerCurrent }
|
|
DESCRIPTION
|
|
"This trap is generated for each and every time the module's
|
|
power line current deviates and causes the boardPowerStatus
|
|
to switch from any states to powerOK(1), or overCurrent(3) state."
|
|
::= 11182
|
|
|
|
boardPowerFrontPanelChanges TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID, boardPowerLocalAdminStatus,
|
|
boardPowerLocalStatus }
|
|
DESCRIPTION
|
|
"This trap is generated for each and every time the module's
|
|
front panel button state changes, it is caused when the
|
|
boardPowerLocalStatus switching state from either one
|
|
of resetRequest(1), powerDownRequest(2), powerOnRequest(3),
|
|
or normal(4) to another."
|
|
::= 11183
|
|
|
|
boardPowerOperationalChanges TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID, boardPowerOperationalStatus }
|
|
DESCRIPTION
|
|
"This trap is generated for each and every time the module's
|
|
DC-DC converter power supply voltage deviates and causes the
|
|
boardPowerOperationalStatus to switch state from powerOn(1),
|
|
powerOff(2), reset(3), overVoltage(4), underVoltage(5),
|
|
overCurrent(6), overCurrentShutdown(7), temperatureShutdown(8),
|
|
remotePowerOff(9), powerConservationShutdown(10), or
|
|
frontPanelPowerOff(11) to another."
|
|
::= 11184
|
|
|
|
psEnvTempChanges TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psEnvSlotID, psEnvTempStatus, psEnvTemp }
|
|
DESCRIPTION
|
|
"This trap is generated for each and every time the power
|
|
supply temperature crosses over a threshold value of either
|
|
one of the power supply set thresholds psEnvTempHot,
|
|
psEnvTempWarm, psEnvTempCool, or psEnvTempCold to another.
|
|
This trap is also sent when the power supply temperature
|
|
sensor is detected to be broken or not supported."
|
|
::= 11185
|
|
|
|
psEnvFanChanges TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psEnvSlotID, psEnvFanStatus, psEnvFanSpeed }
|
|
DESCRIPTION
|
|
"This trap is generated for each and every time the power
|
|
supply fan changes over its status from either one value
|
|
unknown(1), normal(2), testing(3), slow(4), inoperative(5),
|
|
or off(6) to another."
|
|
::= 11186
|
|
|
|
psPowerVoltageChanges TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotID, psPowerID,
|
|
psPowerStatus, psPowerVoltage }
|
|
DESCRIPTION
|
|
"This trap is generated for each and every time the module's
|
|
power line voltage deviates and causes the psPowerStatus
|
|
to switch from any states to either powerOK(1), overVoltage(4),
|
|
or underVoltage(5) state."
|
|
::= 11187
|
|
|
|
psPowerCurrentChanges TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotID, psPowerID,
|
|
psPowerStatus, psPowerCurrent }
|
|
DESCRIPTION
|
|
"This trap is generated for each and every time the module's
|
|
power line current deviates and causes the psPowerStatus
|
|
to switch from any states to powerOK(1), or overCurrent(3) state."
|
|
::= 11188
|
|
|
|
psPowerAdminChanges TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotID, psPowerID, psPowerAdmin }
|
|
DESCRIPTION
|
|
"This trap is generated for each and every time the power
|
|
supply power line changes state from one operational mode
|
|
to another switching between powerOn(1) and powerOff(2)."
|
|
::= 11189
|
|
|
|
psPowerOperationalChanges TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID, psPowerOperationalStatus}
|
|
DESCRIPTION
|
|
"This trap is generated for each and every time the module's
|
|
DC-DC converter power supply voltage deviates and causes the
|
|
psPowerOperationalStatus to switch state from either one
|
|
of powerOn(1), powerOff(2), reset(3), overVoltage(4),
|
|
underVoltage(5), overCurrent(6), overCurrentShutdown(7),
|
|
temperatureShutdown(8), or remotePowerOff(9) to another."
|
|
::= 11190
|
|
|
|
boardInserted TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated when an MMACplus card
|
|
is inserted in the chassis."
|
|
::= 11191
|
|
|
|
boardRemoved TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { boardPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated when an MMACplus card
|
|
is removed from the chassis."
|
|
::= 11192
|
|
|
|
psInserted TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated when an MMACplus power supply
|
|
is inserted in the chassis."
|
|
::= 11193
|
|
|
|
psRemoved TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated when an MMACplus power supply
|
|
is removed from the chassis."
|
|
::= 11194
|
|
|
|
psRedundant TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated when an MMACplus power supply
|
|
has a redundant power supply"
|
|
::= 11195
|
|
|
|
psNotRedundant TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { chPowerLineMaxSupply, chPowerLineTotalSupply }
|
|
DESCRIPTION
|
|
"This trap is generated when an MMACplus power supply
|
|
has no redundant power supply"
|
|
::= 11196
|
|
|
|
psNormal TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated when an MMACplus board is
|
|
transitioning to a normal state from a fault state"
|
|
::= 11197
|
|
|
|
psFault TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { psPowerSlotStatusID }
|
|
DESCRIPTION
|
|
"This trap is generated when an MMACplus power supply
|
|
is not operational"
|
|
::= 11198
|
|
|
|
upsLineFail TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { upsIndex }
|
|
DESCRIPTION
|
|
"This trap is generated in the event of an AC utility
|
|
line failure."
|
|
::= 11200
|
|
|
|
upsLineFailRecovery TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { upsIndex }
|
|
DESCRIPTION
|
|
"This trap is generated when the UPS switches back
|
|
to line, and only if the upsLineFail trap was issued
|
|
first."
|
|
::= 11201
|
|
|
|
upsLowBattery TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { upsIndex }
|
|
DESCRIPTION
|
|
"This trap is generated in the event that the UPS's
|
|
battery is found to be low."
|
|
::= 11202
|
|
|
|
upsLowBatteryRecovery TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { upsIndex }
|
|
DESCRIPTION
|
|
"This trap is generated when the UPS's battery has
|
|
charged above the low-battery point, and only if the
|
|
upsLowBattery trap was issued first."
|
|
::= 11203
|
|
|
|
upsAbnormalCondition TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { upsIndex, upsStatusFault, upsAddlFuncsStatusFault }
|
|
DESCRIPTION
|
|
"This trap is generated in the event that the UPS
|
|
has entered an abnormal condition, such as an
|
|
overload or trip on low battery. This trap is also
|
|
sent when the UPS is first turned on."
|
|
::= 11204
|
|
|
|
upsAbnormalConditionRecovery TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { upsIndex }
|
|
DESCRIPTION
|
|
"This trap is generated when the UPS has recovered
|
|
from an abnormal condition, and only if the
|
|
upsAbnormalCondition trap was issued first."
|
|
::= 11205
|
|
|
|
upsShuttingDown TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { upsIndex }
|
|
DESCRIPTION
|
|
"This trap is generated in the event that the UPS
|
|
has been ordered to shut itself, or the load, off
|
|
over the serial line."
|
|
::= 11206
|
|
|
|
upsReplaceBattery TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { upsIndex }
|
|
DESCRIPTION
|
|
"This trap is generated when the UPS's battery test
|
|
has determined that a UPS battery is unable to retain
|
|
adequate charge. This trap will be generated every
|
|
five hours until a new battery test is run or the
|
|
UPS is turned off."
|
|
::= 11207
|
|
|
|
upsExtMeasAlarm TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { upsIndex, upsExtMeasAlarmStatus }
|
|
DESCRIPTION
|
|
"This trap is generated when the External Measurement Unit
|
|
has detected that an ambient temperature or humidity limit
|
|
extreme has been exceeded, or that one of the contact closure
|
|
inputs has changed from the selected `normal' state. In
|
|
the case of multiple alarms, a trap is generated for every
|
|
alarm condition detected. In addition, the trap is sent
|
|
every two minutes whenever an alarm condition exists. It
|
|
is discontinued when all alarm conditions are reset. This
|
|
trap is sent only for alarm states that have been enabled."
|
|
::= 11208
|
|
|
|
nvmpUdefTrap TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
DESCRIPTION
|
|
"This trap is generated when a new NVMP trap is sent that
|
|
does not have an SNMP counterpart."
|
|
::= 11999
|
|
|
|
--
|
|
-- ================================================================
|
|
-- Trap values from 12000 - 12500 are reserved for ATM specific traps.
|
|
--
|
|
|
|
activePortInATMRedundancyFailed TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ctATMPhyRedundIfIndex }
|
|
DESCRIPTION
|
|
"This trap will be generated when the active port, on a physical ATM
|
|
interface that has redundancy enabled, has failed (become quiet)."
|
|
::= 12000
|
|
|
|
aTMRedundantPortActivated TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ctATMPhyRedundIfIndex }
|
|
DESCRIPTION
|
|
"This trap indicates that a new port has been activated on a
|
|
physical ATM interface that has redundancy enabled. This does
|
|
not indicate that this port is usable, but that it is being
|
|
tested as a possible replacement."
|
|
::= 12001
|
|
|
|
aTMRedundanctPortTestFailed TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ctATMPhyRedundIfIndex }
|
|
DESCRIPTION
|
|
"This trap will be generated when the phyRedundIfTestTOD or the
|
|
phyRedundIfPerformTest has tested a port and determined that it
|
|
is not usable. The port should be fixed prior to it being needed."
|
|
::= 12002
|
|
|
|
aTMRedundPrimaryPortSkipped TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ctATMPhyRedundIfIndex }
|
|
DESCRIPTION
|
|
"This trap will be generated when redundancy finds that the primary
|
|
port as designated be PhyRedundIfPrimaryPort is usable but cannot be
|
|
used because PhyRedundIfPrimaryRevert is set to manual (2). This
|
|
trap is generated only when redundancy is enabled (PhyRedundIfStatus
|
|
is enable (1)) and the active port fails."
|
|
::= 12003
|
|
|
|
--atmHostAddressRegister TRAP-TYPE
|
|
-- ENTERPRISE cabletron
|
|
-- VARIABLES { atmIfAdminAddrRowStatus }
|
|
-- DESCRIPTION
|
|
-- "This trap signifies that the agent has detected
|
|
-- an atm address registration on a port."
|
|
-- ::= 12004
|
|
|
|
-- atmHostAddressDeRegister TRAP-TYPE
|
|
-- ENTERPRISE cabletron
|
|
-- VARIABLES { atmIfAdminAddrRowStatus }
|
|
-- DESCRIPTION
|
|
-- "This trap signifies that the agent has detected
|
|
-- an atm address deregistration on a port."
|
|
-- ::= 12005
|
|
|
|
atmCTMUp TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
DESCRIPTION
|
|
"This trap signifies that the agent has detected
|
|
the CTM operational. Connection set maps are allowed
|
|
through the switch"
|
|
::= 12006
|
|
|
|
atmCTMDown TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
DESCRIPTION
|
|
"This trap signifies that the agent has detected
|
|
the CTM unoperational. A list of Cross Connect Ids
|
|
will be sent indicating connections that need to be removed."
|
|
::= 12007
|
|
|
|
atmVcCrossConnectOperChange TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { atmVcCrossConnectRowStatus }
|
|
DESCRIPTION
|
|
"This trap signifies that the agent has detected
|
|
a change in the operational status to down. A list of VC cross
|
|
connections will be sent to be remapped."
|
|
::= 12008
|
|
|
|
atmVpCrossConnectOperChange TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { atmVpCrossConnectRowStatus }
|
|
DESCRIPTION
|
|
"This trap signifies that the agent has detected
|
|
a change in the operational status to down. A list of VP cross
|
|
connections will be sent to be remapped."
|
|
::= 12009
|
|
|
|
atmNeighborSwitchUp TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { atmInterfaceMyNeighborIpAddress,
|
|
atmInterfaceMyNeighborIfName }
|
|
DESCRIPTION
|
|
"This trap signifies that the agent has detected
|
|
a neighbor switch on a port."
|
|
::= 12010
|
|
|
|
atmNeighborSwitchDown TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { atmInterfaceMyNeighborIpAddress,
|
|
atmInterfaceMyNeighborIfName }
|
|
DESCRIPTION
|
|
"This trap signifies that the agent has detected
|
|
a lost neighbor switch on a port."
|
|
::= 12011
|
|
|
|
callFailure TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex }
|
|
DESCRIPTION
|
|
"SPVC Call Failures."
|
|
::= 12012
|
|
|
|
allocBwHiFwd TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex }
|
|
DESCRIPTION
|
|
"Allocated bandwidth for this port has exceeded the
|
|
allocBwThresholdHiFwd."
|
|
::= 12013
|
|
|
|
allocBwHiRev TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex }
|
|
DESCRIPTION
|
|
"Allocated bandwidth for this port has exceeded the
|
|
allocBwThresholdHiRev."
|
|
::= 12014
|
|
|
|
allocBwLoFwd TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex }
|
|
DESCRIPTION
|
|
"Allocated bandwidth for this port is below the
|
|
allocBwThresholdLoFwd."
|
|
::= 12015
|
|
|
|
allocBwLoRev TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex }
|
|
DESCRIPTION
|
|
"Allocated bandwidth for this port is below the
|
|
allocBwThresholdLoRev."
|
|
::= 12016
|
|
|
|
aggPcrFwd TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex }
|
|
DESCRIPTION
|
|
"The total of all the aggregate peak cell rates for the VCs using
|
|
this port exceeds the physical bandwidth of the port in the forward
|
|
direction."
|
|
::= 12017
|
|
|
|
aggPcrRev TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex }
|
|
DESCRIPTION
|
|
"The total of all the aggregate peak cell rates for the VCs using
|
|
this port exceeds the physical bandwidth of the port in the reverse
|
|
direction."
|
|
::= 12018
|
|
|
|
peakFwd TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex }
|
|
DESCRIPTION
|
|
"The peak allocated bandwidth has exceeded the peakBwTholdFwd
|
|
value."
|
|
::= 12019
|
|
|
|
peakRev TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex }
|
|
DESCRIPTION
|
|
"The peak allocated bandwidth has exceeded the peakBwTholdRev
|
|
value."
|
|
::= 12020
|
|
|
|
cbrConnCountTholdHiFwd TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex }
|
|
DESCRIPTION
|
|
"Count of currently active constant bit rate connections exceeding
|
|
the CBRConnectionCountTholdHiFwd threshold."
|
|
::= 12021
|
|
|
|
cbrConnCountTholdHiRev TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex }
|
|
DESCRIPTION
|
|
"Count of currently active CBR connections exceeding the
|
|
CBRConnectionCountTholdHiRev threshold."
|
|
::= 12022
|
|
|
|
cbrConnCountTholdLoFwd TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex }
|
|
DESCRIPTION
|
|
"Count of currently active CBR connections exceeding the
|
|
CBRConnectionCountTholdLoFwd threshold."
|
|
::= 12023
|
|
|
|
cbrConnCountTholdLoRev TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex }
|
|
DESCRIPTION
|
|
"Count of currently active CBR connections exceeding the
|
|
CBRConnectionCountTholdLoRev threshold."
|
|
::= 12024
|
|
|
|
cbrAllocBwTholdHiFwd TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex }
|
|
DESCRIPTION
|
|
"Bandwidth currently allocated which CBR exceeds the
|
|
CBRAllocatedBwTholdHiFwd threshold."
|
|
::= 12025
|
|
|
|
cbrAllocBwTholdHiRev TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex }
|
|
DESCRIPTION
|
|
"Bandwidth currently allocated which CBR exceeds the
|
|
CBRAllocatedBwTholdHiRev threshold."
|
|
::= 12026
|
|
|
|
cbrAllocBwTholdLoFwd TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex }
|
|
DESCRIPTION
|
|
"Bandwidth currently allocated which CBR exceeds the
|
|
CBRAllocatedBwTholdLoFwd threshold."
|
|
::= 12027
|
|
|
|
cbrAllocBwTholdLoRev TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex }
|
|
DESCRIPTION
|
|
"Bandwidth currently allocated which CBR exceeds the
|
|
CBRAllocatedBwTholdLoRev threshold."
|
|
::= 12028
|
|
|
|
vbrConnCountTholdHiFwd TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex }
|
|
DESCRIPTION
|
|
"Count of currently active variable bit rate connections exceeding
|
|
the VBRConnectionCountTholdHiFwd threshold."
|
|
::= 12029
|
|
|
|
vbrConnCountTholdHiRev TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex }
|
|
DESCRIPTION
|
|
"Count of currently active VBR connections exceeding the
|
|
VBRConnectionCountTholdHiRev threshold."
|
|
::= 12030
|
|
|
|
vbrConnCountTholdLoFwd TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex }
|
|
DESCRIPTION
|
|
"Count of currently active VBR connections exceeding the
|
|
VBRConnectionCountTholdLoFwd threshold."
|
|
::= 12031
|
|
|
|
vbrConnCountTholdLoRev TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex }
|
|
DESCRIPTION
|
|
"Count of currently active VBR connections exceeding the
|
|
VBRConnectionCountTholdLoRev threshold."
|
|
::= 12032
|
|
|
|
vbrAllocBwTholdHiFwd TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex }
|
|
DESCRIPTION
|
|
"Bandwidth currently allocated which VBR exceeds the
|
|
VBRAllocatedBwTholdHiFwd threshold."
|
|
::= 12033
|
|
|
|
vbrAllocBwTholdHiRev TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex }
|
|
DESCRIPTION
|
|
"Bandwidth currently allocated which VBR exceeds the
|
|
VBRAllocatedBwTholdHiRev threshold."
|
|
::= 12034
|
|
|
|
vbrAllocBwTholdLoFwd TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex }
|
|
DESCRIPTION
|
|
"Bandwidth currently allocated which VBR exceeds the
|
|
VBRAllocatedBwTholdLoFwd threshold."
|
|
::= 12035
|
|
|
|
vbrAllocBwTholdLoRev TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex }
|
|
DESCRIPTION
|
|
"Bandwidth currently allocated which VBR exceeds the
|
|
VBRAllocatedBwTholdLoRev threshold."
|
|
::= 12036
|
|
|
|
abrConnCountTholdHiFwd TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex }
|
|
DESCRIPTION
|
|
"Count of currently active available bit rate connections
|
|
exceeding the ABRConnectionCountTholdHiFwd threshold."
|
|
::= 12037
|
|
|
|
abrConnCountTholdHiRev TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex }
|
|
DESCRIPTION
|
|
"Count of currently active ABR connections exceeding the
|
|
ABRConnectionCountTholdHiRev threshold."
|
|
::= 12038
|
|
|
|
abrConnCountTholdLoFwd TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex }
|
|
DESCRIPTION
|
|
"Count of currently active ABR connections exceeding the
|
|
ABRConnectionCountTholdLoFwd threshold."
|
|
::= 12039
|
|
|
|
abrConnCountTholdLoRev TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex }
|
|
DESCRIPTION
|
|
"Count of currently active ABR connections exceeding the
|
|
ABRConnectionCountTholdLoRev threshold."
|
|
::= 12040
|
|
|
|
abrAllocBwTholdHiFwd TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex }
|
|
DESCRIPTION
|
|
"Bandwidth currently allocated which ABR exceeds the
|
|
ABRAllocatedBwTholdHiFwd threshold."
|
|
::= 12041
|
|
|
|
abrAllocBwTholdHiRev TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex }
|
|
DESCRIPTION
|
|
"Bandwidth currently allocated which ABR exceeds the
|
|
ABRAllocatedBwTholdHiRev threshold."
|
|
::= 12042
|
|
|
|
abrAllocBwTholdLoFwd TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex }
|
|
DESCRIPTION
|
|
"Bandwidth currently allocated which ABR exceeds the
|
|
ABRAllocatedBwTholdLoFwd threshold."
|
|
::= 12043
|
|
|
|
abrAllocBwTholdLoRev TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex }
|
|
DESCRIPTION
|
|
"Bandwidth currently allocated which ABR exceeds the
|
|
ABRAllocatedBwTholdLoRev threshold."
|
|
::= 12044
|
|
|
|
ubrConnCountTholdHiFwd TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex }
|
|
DESCRIPTION
|
|
"Count of currently active unavailable bit rate connections
|
|
exceeding the UBRConnectionCountTholdHiFwd threshold."
|
|
::= 12045
|
|
|
|
ubrConnCountTholdHiRev TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex }
|
|
DESCRIPTION
|
|
"Count of currently active UBR connections exceeding the
|
|
UBRConnectionCountTholdHiRev threshold."
|
|
::= 12046
|
|
|
|
ubrConnCountTholdLoFwd TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex }
|
|
DESCRIPTION
|
|
"Count of currently active UBR connections exceeding the
|
|
UBRConnectionCountTholdLoFwd threshold."
|
|
::= 12047
|
|
|
|
ubrConnCountTholdLoRev TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex }
|
|
DESCRIPTION
|
|
"Count of currently active UBR connections exceeding the
|
|
UBRConnectionCountTholdLoRev threshold."
|
|
::= 12048
|
|
|
|
ubrAllocBwTholdHiFwd TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex }
|
|
DESCRIPTION
|
|
"Bandwidth currently allocated which UBR exceeds the
|
|
UBRAllocatedBwTholdHiFwd threshold."
|
|
::= 12049
|
|
|
|
-- 12050 is ATM services specific...see below
|
|
|
|
ubrAllocBwTholdLoFwd TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex }
|
|
DESCRIPTION
|
|
"Bandwidth currently allocated which UBR exceeds the
|
|
UBRAllocatedBwTholdLoFwd threshold."
|
|
::= 12051
|
|
|
|
ubrAllocBwTholdLoRev TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex }
|
|
DESCRIPTION
|
|
"Bandwidth currently allocated which UBR exceeds the
|
|
UBRAllocatedBwTholdLoRev threshold."
|
|
::= 12052
|
|
|
|
|
|
ubrAllocBwTholdHiRev TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { ifIndex }
|
|
DESCRIPTION
|
|
"Bandwidth currently allocated which UBR exceeds the
|
|
UBRAllocatedBwTholdHiRev threshold."
|
|
::= 12053
|
|
|
|
--Values 12010-12050 reserved for future ATM traps.
|
|
|
|
atmLecStatus TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { lecRowStatus }
|
|
DESCRIPTION
|
|
"This trap is generated when the operational
|
|
state of the LAN Emulation Client has changed."
|
|
::= 12050
|
|
|
|
--Values 13000-13001 reserved for future ATM traps.
|
|
|
|
boardOperational TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { chSlotID, deviceType }
|
|
DESCRIPTION
|
|
"This trap will be generated when an entity detects
|
|
that a module has become operational."
|
|
::= 13000
|
|
|
|
boardNonOperational TRAP-TYPE
|
|
ENTERPRISE cabletron
|
|
VARIABLES { chSlotID }
|
|
DESCRIPTION
|
|
"This trap will be generated when an entity detects
|
|
that a module is no longer operational."
|
|
::= 13001
|
|
|
|
END
|