--/** AKCP, Ltd */
|
|
--/** Proprietary and Confidential Information */
|
|
--/** */
|
|
--/** This material contains, and is part of a computer software program */
|
|
--/** which is, proprietary and confidential information owned by AKCP,Ltd */
|
|
--/** The program, including this material, */
|
|
--/** may not be duplicated, disclosed or reproduced in whole or in part for */
|
|
--/** any purpose without the express written authorization of AKCP, Ltd */
|
|
--/** All authorized reproductions must be marked with this legend. */
|
|
--/** */
|
|
--/** */
|
|
--/** Copyright (c) 1994-2007 */
|
|
--/** AKCP, Ltd */
|
|
--/** All rights reserved */
|
|
--/** */
|
|
--/***************************************************************************/
|
|
|
|
--/***************************************************************************/
|
|
--/** */
|
|
--/** This MIB is a superset which includes all of the features in the */
|
|
--/** sensorProbe family. Some features may not be implemented in certain */
|
|
--/** models. */
|
|
--/** */
|
|
--/***************************************************************************/
|
|
--
|
|
--/*
|
|
-- * Change Log
|
|
-- *
|
|
-- * 24/12/2009 Ji : bug:1657 - Separate the email and traps in sensor filter and send Trap/Email for sensor on port
|
|
-- * 29/12/2009 Ji : bug:1801 - New OID for detect sensor status
|
|
-- * 03/03/2010 Ji : bug:1992 - degreeRaw of sensorTemperatureTable return sensorIndex
|
|
-- * 05/03/2010 Ji : bug:1994 - new OID for sensorPort sensorsubPort and sensorDeviceIndex
|
|
-- * 04/05/2010 Ek : bug:2078 - new OID for sensor type name
|
|
-- * 04/05/2010 chaiylee : bug:2078 - new OID for hostname
|
|
-- * 03/06/2010 chaiylee : bug:2078 - Add sensor setting default for DC and 4-20ma
|
|
-- * 03/06/2010 bom : bug:2142 - Add gauge to analog sensor web interface
|
|
-- * 22/06/2010 bom : bug:2201 - validation akcp.mib at http://www.simpleweb.org/ietf/mibs/validate/
|
|
-- * 02/11/2010 Chaiylee : bug:2463 - Add the new Tank Sender sensor
|
|
-- * 16/11/2010 Ji : bug:2493 - Some OID do not update in MIB file
|
|
-- *
|
|
-- */
|
|
|
|
SPAGENT-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
enterprises, IpAddress, Gauge
|
|
FROM RFC1155-SMI
|
|
OBJECT-TYPE
|
|
FROM RFC-1212
|
|
DisplayString
|
|
FROM RFC1213-MIB
|
|
TRAP-TYPE
|
|
FROM RFC-1215;
|
|
|
|
|
|
akcp OBJECT IDENTIFIER ::= { enterprises 3854 }
|
|
sensorProbe OBJECT IDENTIFIER ::= { akcp 1 }
|
|
|
|
|
|
spSummary OBJECT IDENTIFIER ::= { sensorProbe 1 }
|
|
|
|
spStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
warning(3),
|
|
critical(4),
|
|
sensorError(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this sensorProbe. The status of the sensorProbe is the worst status of all the sensors under the control of this sensorProbe."
|
|
::= { spSummary 2 }
|
|
|
|
spManufName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The manufacturers name"
|
|
::= { spSummary 6 }
|
|
|
|
spHelpUrl OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The URL of the web based help"
|
|
::= { spSummary 7 }
|
|
|
|
spProductName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The product name"
|
|
::= { spSummary 8 }
|
|
|
|
spHostName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The hostname"
|
|
::= { spSummary 9 }
|
|
|
|
spSensor OBJECT IDENTIFIER ::= { sensorProbe 2 }
|
|
|
|
sensorProbeDetail OBJECT IDENTIFIER ::= { spSensor 2 }
|
|
|
|
sensorProbeEntry OBJECT IDENTIFIER ::= { sensorProbeDetail 1 }
|
|
|
|
sensorProbeHost OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Host of this sensor, this is the IP address"
|
|
::= { sensorProbeEntry 1 }
|
|
|
|
sensorProbeUseDHCP OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
yes(1),
|
|
no(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To use DHCP enter a 1, to use a static IP address enter a 2"
|
|
::= { sensorProbeEntry 2 }
|
|
|
|
sensorProbeMAC OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The MAC address of this system"
|
|
::= { sensorProbeEntry 3 }
|
|
|
|
sensorProbeSetCommunity OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The sensorProbe community string used for snmp Sets"
|
|
::= { sensorProbeEntry 4 }
|
|
|
|
sensorProbeGetCommunity OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The sensorProbe community string used for snmp Gets"
|
|
::= { sensorProbeEntry 5 }
|
|
|
|
sensorProbeTempTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorProbeTempEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the data for every Temperature Sensor in the SensorArray. Each row in the table contains data for a different Temperature Sensor."
|
|
::= { sensorProbeEntry 16 }
|
|
|
|
sensorProbeTempEntry OBJECT-TYPE
|
|
SYNTAX SensorProbeTempEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorProbeTempEntry Table"
|
|
INDEX { sensorProbeTempIndex }
|
|
::= { sensorProbeTempTable 1 }
|
|
|
|
SensorProbeTempEntry ::= SEQUENCE {
|
|
sensorProbeTempDescription
|
|
DisplayString,
|
|
sensorProbeTempLocation
|
|
DisplayString,
|
|
sensorProbeTempDegree
|
|
INTEGER,
|
|
sensorProbeTempStatus
|
|
INTEGER,
|
|
sensorProbeTempOnline
|
|
INTEGER,
|
|
sensorProbeTempGoOnline
|
|
INTEGER,
|
|
sensorProbeTempHighWarning
|
|
INTEGER,
|
|
sensorProbeTempHighCritical
|
|
INTEGER,
|
|
sensorProbeTempLowWarning
|
|
INTEGER,
|
|
sensorProbeTempLowCritical
|
|
INTEGER,
|
|
sensorProbeTempRearm
|
|
INTEGER,
|
|
sensorProbeTempDegreeType
|
|
INTEGER,
|
|
sensorProbeTempSensorType
|
|
INTEGER,
|
|
sensorProbeTempDegreeRaw
|
|
INTEGER,
|
|
sensorProbeTempEmailTrapLimit
|
|
INTEGER,
|
|
sensorProbeTempEmailTrapSchedule
|
|
DisplayString,
|
|
sensorProbeTempEmailTrapInterval
|
|
INTEGER,
|
|
sensorProbeTempSendNormalTrap
|
|
INTEGER,
|
|
sensorProbeTempDelayError
|
|
INTEGER,
|
|
sensorProbeTempDelayNormal
|
|
INTEGER,
|
|
sensorProbeTempIndex
|
|
INTEGER,
|
|
sensorProbeTempRelayCycleTime
|
|
INTEGER,
|
|
sensorProbeTempRelayOnPort
|
|
INTEGER,
|
|
sensorProbeTempRelayActiveStatus
|
|
INTEGER,
|
|
sensorProbeTempRelayAction
|
|
INTEGER,
|
|
sensorProbeTempEmailInterval
|
|
INTEGER,
|
|
sensorProbeTempIndexCount
|
|
INTEGER,
|
|
sensorProbeTempOffset
|
|
INTEGER,
|
|
sensorProbeTempSirenCycleTime
|
|
INTEGER,
|
|
sensorProbeTempSirenOnPort
|
|
INTEGER,
|
|
sensorProbeTempSirenActiveStatus
|
|
INTEGER,
|
|
sensorProbeTempSirenAction
|
|
INTEGER,
|
|
sensorProbeTempAcknowledgement
|
|
INTEGER,
|
|
sensorProbeTempSirenDelayAlarm
|
|
INTEGER,
|
|
sensorProbeTempURL
|
|
DisplayString,
|
|
sensorProbeTempOpenURL
|
|
INTEGER,
|
|
sensorProbeTempDatacollectType
|
|
INTEGER,
|
|
sensorProbeTempContTimeHighCritical
|
|
INTEGER,
|
|
sensorProbeTempContTimeHighWarning
|
|
INTEGER,
|
|
sensorProbeTempContTimeNormal
|
|
INTEGER,
|
|
sensorProbeTempContTimeLowWarning
|
|
INTEGER,
|
|
sensorProbeTempContTimeLowCritical
|
|
INTEGER,
|
|
sensorProbeTempContTimeSensorError
|
|
INTEGER,
|
|
sensorProbeTempCalendar
|
|
INTEGER,
|
|
sensorProbeThermostatIndex
|
|
INTEGER,
|
|
sensorProbeThermostatDescription
|
|
DisplayString,
|
|
sensorProbeThermostatValue
|
|
INTEGER,
|
|
sensorProbeThermostatOnline
|
|
INTEGER,
|
|
sensorProbeThermostatGoOnline
|
|
INTEGER,
|
|
sensorProbeThermostatMode
|
|
INTEGER,
|
|
sensorProbeThermostatRelayControlPort
|
|
INTEGER,
|
|
sensorProbeThermostatNormalAction1
|
|
INTEGER,
|
|
sensorProbeThermostatHighLimit1
|
|
INTEGER,
|
|
sensorProbeThermostatHighLimitAction1
|
|
INTEGER,
|
|
sensorProbeThermostatLowLimit1
|
|
INTEGER,
|
|
sensorProbeThermostatLowLimitAction1
|
|
INTEGER,
|
|
sensorProbeThermostatNormalAction2
|
|
INTEGER,
|
|
sensorProbeThermostatHighLimit2
|
|
INTEGER,
|
|
sensorProbeThermostatHighLimitAction2
|
|
INTEGER,
|
|
sensorProbeThermostatLowLimit2
|
|
INTEGER,
|
|
sensorProbeThermostatLowLimitAction2
|
|
INTEGER,
|
|
sensorProbeThermostatEnableTime
|
|
DisplayString,
|
|
sensorProbeTempSendNormalMail
|
|
INTEGER,
|
|
sensorProbeTempSendTrap
|
|
INTEGER,
|
|
sensorProbeTempSendMail
|
|
INTEGER
|
|
}
|
|
sensorProbeTempDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor"
|
|
::= { sensorProbeTempEntry 1 }
|
|
|
|
sensorProbeTempLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The physical location of this sensor"
|
|
::= { sensorProbeTempEntry 2 }
|
|
|
|
sensorProbeTempDegree OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The degrees in this sensor"
|
|
::= { sensorProbeTempEntry 3 }
|
|
|
|
sensorProbeTempStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highWarning(3),
|
|
highCritical(4),
|
|
lowWarning(5),
|
|
lowCritical(6),
|
|
sensorError(7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor"
|
|
::= { sensorProbeTempEntry 4 }
|
|
|
|
sensorProbeTempOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
offline(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If this Sensor is currently online"
|
|
::= { sensorProbeTempEntry 5 }
|
|
|
|
sensorProbeTempGoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To put online enter a 1, to take offline enter a 2"
|
|
::= { sensorProbeTempEntry 6 }
|
|
|
|
sensorProbeTempHighWarning OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How hot this sensor gets before it sends a warning"
|
|
::= { sensorProbeTempEntry 7 }
|
|
|
|
sensorProbeTempHighCritical OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How hot this sensor gets before it sends a critical event"
|
|
::= { sensorProbeTempEntry 8 }
|
|
|
|
sensorProbeTempLowWarning OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How cold this sensor gets before it sends a warning"
|
|
::= { sensorProbeTempEntry 9 }
|
|
|
|
sensorProbeTempLowCritical OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How cold this sensor gets before it sends a critical event"
|
|
::= { sensorProbeTempEntry 10 }
|
|
|
|
sensorProbeTempRearm OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of degrees to rearm the status. For example if status goes from normal to warning, the temp must go down spTempRearm degrees below warning before the status goes to normal"
|
|
::= { sensorProbeTempEntry 11 }
|
|
|
|
sensorProbeTempDegreeType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
fahr(0),
|
|
celsius(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The degrees are in fahrenheit(0) or in celsius(1)"
|
|
::= { sensorProbeTempEntry 12 }
|
|
|
|
sensorProbeTempSensorType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
type1(0),
|
|
type2(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of temperture sensor"
|
|
::= { sensorProbeTempEntry 13 }
|
|
|
|
sensorProbeTempDegreeRaw OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SP Only: The raw degree data from the temperature sensor, slightly higher resolution"
|
|
::= { sensorProbeTempEntry 14 }
|
|
|
|
sensorProbeTempEmailTrapLimit OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable email/trap limit feature"
|
|
::= { sensorProbeTempEntry 16 }
|
|
|
|
sensorProbeTempEmailTrapSchedule OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SP Only: Email/trap limit schedule for this sensor"
|
|
::= { sensorProbeTempEntry 17 }
|
|
|
|
sensorProbeTempEmailTrapInterval OBJECT-TYPE
|
|
SYNTAX INTEGER (0..60)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minimum time between each [email/trap:SP, only trap:CP8] (can be from 0 to 60 minutes)."
|
|
::= { sensorProbeTempEntry 18 }
|
|
|
|
sensorProbeTempSendNormalTrap OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable sending email/trap when sensor goes to normal"
|
|
::= { sensorProbeTempEntry 19 }
|
|
|
|
sensorProbeTempDelayError OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time in seconds after the sensor has been in error status before report as an error"
|
|
::= { sensorProbeTempEntry 20 }
|
|
|
|
sensorProbeTempDelayNormal OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time in seconds after the sensor change from error to normal before report as normal"
|
|
::= { sensorProbeTempEntry 21 }
|
|
|
|
sensorProbeTempIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..7)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index into the temperature sensor table"
|
|
::= { sensorProbeTempEntry 22 }
|
|
|
|
sensorProbeTempRelayCycleTime OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Relay toggle period in seconds for Cycle action."
|
|
::= { sensorProbeTempEntry 23 }
|
|
|
|
sensorProbeTempRelayOnPort OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The sensor port that the relay will listen to. If this is set to 255, then the relay will not listen to any sensor ports"
|
|
::= { sensorProbeTempEntry 24 }
|
|
|
|
sensorProbeTempRelayActiveStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
highWarning(3),
|
|
highCritical(4),
|
|
lowWarning(5),
|
|
lowCritical(6),
|
|
anyError(7)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor status that will activate the relay"
|
|
::= { sensorProbeTempEntry 25 }
|
|
|
|
sensorProbeTempRelayAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cycle(2),
|
|
turn-on(3),
|
|
turn-off(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"What the relay will do when the listened to port status turns to the specified active status."
|
|
::= { sensorProbeTempEntry 26 }
|
|
|
|
sensorProbeTempEmailInterval OBJECT-TYPE
|
|
SYNTAX INTEGER (0..60)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"CP8 Only: Minimum time between each email (can be from 0 to 60 minutes)"
|
|
::= { sensorProbeTempEntry 27 }
|
|
|
|
sensorProbeTempIndexCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of Temperature sensor online"
|
|
::= { sensorProbeTempEntry 28 }
|
|
|
|
sensorProbeTempOffset OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Temperature Offset reading"
|
|
::= { sensorProbeTempEntry 29 }
|
|
|
|
sensorProbeTempSirenCycleTime OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Siren toggle period in seconds for Cycle action."
|
|
::= { sensorProbeTempEntry 30 }
|
|
|
|
sensorProbeTempSirenOnPort OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The sensor port that the siren will listen to. If this is set to 255, then the siren will not listen to any sensor ports"
|
|
::= { sensorProbeTempEntry 31 }
|
|
|
|
sensorProbeTempSirenActiveStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
highWarning(3),
|
|
highCritical(4),
|
|
lowWarning(5),
|
|
lowCritical(6),
|
|
anyError(7)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor status that will activate the siren"
|
|
::= { sensorProbeTempEntry 32 }
|
|
|
|
sensorProbeTempSirenAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cycle(2),
|
|
turn-on(3),
|
|
turn-off(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"What the siren will do when the listened to port status turns to the specified active status."
|
|
::= { sensorProbeTempEntry 33 }
|
|
|
|
sensorProbeTempAcknowledgement OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ack(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Acknowledged sensor error and stop notification"
|
|
::= { sensorProbeTempEntry 34 }
|
|
|
|
sensorProbeTempSirenDelayAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Siren delay in seconds before start Alarm."
|
|
::= { sensorProbeTempEntry 35 }
|
|
|
|
sensorProbeTempURL OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor URL link."
|
|
::= { sensorProbeTempEntry 36 }
|
|
|
|
sensorProbeTempOpenURL OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cur-window(0),
|
|
new-window(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Open URL in this browser or open in a new window."
|
|
::= { sensorProbeTempEntry 37 }
|
|
|
|
sensorProbeTempDatacollectType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
average(1),
|
|
highest(2),
|
|
lowest(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Type of datacollect to collect."
|
|
::= { sensorProbeTempEntry 38 }
|
|
|
|
sensorProbeTempContTimeHighCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in High Critical before accepting new Status."
|
|
::= { sensorProbeTempEntry 39 }
|
|
|
|
sensorProbeTempContTimeHighWarning OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in High Warning before accepting new Status."
|
|
::= { sensorProbeTempEntry 40 }
|
|
|
|
sensorProbeTempContTimeNormal OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Normal before accepting new Status."
|
|
::= { sensorProbeTempEntry 41 }
|
|
|
|
sensorProbeTempContTimeLowWarning OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Low Warning before accepting new Status."
|
|
::= { sensorProbeTempEntry 42 }
|
|
|
|
sensorProbeTempContTimeLowCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Low Critical before accepting new Status."
|
|
::= { sensorProbeTempEntry 43 }
|
|
|
|
sensorProbeTempContTimeSensorError OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Sensor Error before accepting new Status."
|
|
::= { sensorProbeTempEntry 44 }
|
|
|
|
sensorProbeTempCalendar OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable the calendar filtering working hours of sensor."
|
|
::= { sensorProbeTempEntry 45 }
|
|
|
|
sensorProbeThermostatIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value for each sensor thermostat port."
|
|
::= { sensorProbeTempEntry 46 }
|
|
|
|
sensorProbeThermostatDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor thermostat"
|
|
::= { sensorProbeTempEntry 47 }
|
|
|
|
sensorProbeThermostatValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value in this sensor"
|
|
::= { sensorProbeTempEntry 48 }
|
|
|
|
sensorProbeThermostatOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
offline(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If this Sensor is currently online"
|
|
::= { sensorProbeTempEntry 49 }
|
|
|
|
sensorProbeThermostatGoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To put online enter a 1, to take offline enter a 2"
|
|
::= { sensorProbeTempEntry 50 }
|
|
|
|
sensorProbeThermostatMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal(0),
|
|
time-bases(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To select the thermostat mode for working on time-bases(1) or normal(0)."
|
|
::= { sensorProbeTempEntry 51 }
|
|
|
|
sensorProbeThermostatRelayControlPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To select a relay port to be controled by this thermostat sensor."
|
|
::= { sensorProbeTempEntry 52 }
|
|
|
|
sensorProbeThermostatNormalAction1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile1: Thermostat normal action for controlling a relay sensor."
|
|
::= { sensorProbeTempEntry 53 }
|
|
|
|
sensorProbeThermostatHighLimit1 OBJECT-TYPE
|
|
SYNTAX INTEGER (-40..167)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile1: When this sersor higher than thermostat high limit, it will take a high limit action."
|
|
::= { sensorProbeTempEntry 54 }
|
|
|
|
sensorProbeThermostatHighLimitAction1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile1: Thermostat high limit action for controlling a relay sensor."
|
|
::= { sensorProbeTempEntry 55 }
|
|
|
|
sensorProbeThermostatLowLimit1 OBJECT-TYPE
|
|
SYNTAX INTEGER (-40..167)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile1: When this sersor higher than thermostat low limit, it will take a normal limit action."
|
|
::= { sensorProbeTempEntry 56 }
|
|
|
|
sensorProbeThermostatLowLimitAction1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile1: Thermostat low limit action for controlling a relay sensor."
|
|
::= { sensorProbeTempEntry 57 }
|
|
|
|
sensorProbeThermostatNormalAction2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile2: Thermostat normal action for controlling a relay sensor."
|
|
::= { sensorProbeTempEntry 58 }
|
|
|
|
sensorProbeThermostatHighLimit2 OBJECT-TYPE
|
|
SYNTAX INTEGER (-40..167)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile2: When this sersor higher than thermostat high limit, it will take a high limit action."
|
|
::= { sensorProbeTempEntry 59 }
|
|
|
|
sensorProbeThermostatHighLimitAction2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile2: Thermostat high limit action for controlling a relay sensor."
|
|
::= { sensorProbeTempEntry 60 }
|
|
|
|
sensorProbeThermostatLowLimit2 OBJECT-TYPE
|
|
SYNTAX INTEGER (-40..167)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile2: When this sersor higher than thermostat low limit, it will take a normal limit action."
|
|
::= { sensorProbeTempEntry 61 }
|
|
|
|
sensorProbeThermostatLowLimitAction2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile2: Thermostat low limit action for controlling a relay sensor."
|
|
::= { sensorProbeTempEntry 62 }
|
|
|
|
sensorProbeThermostatEnableTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time to enable on Thermostat"
|
|
::= { sensorProbeTempEntry 63 }
|
|
|
|
sensorProbeTempSendNormalMail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable sending email when sensor goes to normal"
|
|
::= { sensorProbeTempEntry 64 }
|
|
|
|
sensorProbeTempSendTrap OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable sending trap when sensor change status"
|
|
::= { sensorProbeTempEntry 65 }
|
|
|
|
sensorProbeTempSendMail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable sending email when sensor change status"
|
|
::= { sensorProbeTempEntry 66 }
|
|
|
|
sensorProbeHumidityTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorProbeHumidityEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the data for every Humidity Sensor in the SensorArray. Each row in the table contains data for a different Humidity Sensor."
|
|
::= { sensorProbeEntry 17 }
|
|
|
|
sensorProbeHumidityEntry OBJECT-TYPE
|
|
SYNTAX SensorProbeHumidityEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorProbeHumidityEntry Table"
|
|
INDEX { sensorProbeHumidityIndex }
|
|
::= { sensorProbeHumidityTable 1 }
|
|
|
|
SensorProbeHumidityEntry ::= SEQUENCE {
|
|
sensorProbeHumidityDescription
|
|
DisplayString,
|
|
sensorProbeHumidityLocation
|
|
DisplayString,
|
|
sensorProbeHumidityPercent
|
|
INTEGER,
|
|
sensorProbeHumidityStatus
|
|
INTEGER,
|
|
sensorProbeHumidityOnline
|
|
INTEGER,
|
|
sensorProbeHumidityGoOnline
|
|
INTEGER,
|
|
sensorProbeHumidityHighWarning
|
|
INTEGER,
|
|
sensorProbeHumidityHighCritical
|
|
INTEGER,
|
|
sensorProbeHumidityLowWarning
|
|
INTEGER,
|
|
sensorProbeHumidityLowCritical
|
|
INTEGER,
|
|
sensorProbeHumidityRearm
|
|
INTEGER,
|
|
sensorProbeHumidityRaw
|
|
INTEGER,
|
|
sensorProbeHumidityLowVoltage
|
|
INTEGER,
|
|
sensorProbeHumidityHighVoltage
|
|
INTEGER,
|
|
sensorProbeHumidityEmailTrapLimit
|
|
INTEGER,
|
|
sensorProbeHumidityEmailTrapSchedule
|
|
DisplayString,
|
|
sensorProbeHumidityEmailTrapInterval
|
|
INTEGER,
|
|
sensorProbeHumiditySendNormalTrap
|
|
INTEGER,
|
|
sensorProbeHumidityDelayError
|
|
INTEGER,
|
|
sensorProbeHumidityDelayNormal
|
|
INTEGER,
|
|
sensorProbeHumidityIndex
|
|
INTEGER,
|
|
sensorProbeHumidityAtoDAmountMaxVoltage
|
|
INTEGER,
|
|
sensorProbeHumidityAtoDAmountBaseVoltage
|
|
INTEGER,
|
|
sensorProbeHumidityAtoDTypeUnit
|
|
INTEGER,
|
|
sensorProbeHumidityDcUnit
|
|
DisplayString,
|
|
sensorProbeHumidityAtoDJumper
|
|
INTEGER,
|
|
sensorProbeHumidityRelayCycleTime
|
|
INTEGER,
|
|
sensorProbeHumidityRelayOnPort
|
|
INTEGER,
|
|
sensorProbeHumidityRelayActiveStatus
|
|
INTEGER,
|
|
sensorProbeHumidityRelayAction
|
|
INTEGER,
|
|
sensorProbeHumidityEmailInterval
|
|
INTEGER,
|
|
sensorProbeHumidity4to20mAUnit
|
|
DisplayString,
|
|
sensorProbeHumidityIndexCount
|
|
INTEGER,
|
|
sensorProbeHumidityOffset
|
|
INTEGER,
|
|
sensorProbeHumiditySirenCycleTime
|
|
INTEGER,
|
|
sensorProbeHumiditySirenOnPort
|
|
INTEGER,
|
|
sensorProbeHumiditySirenActiveStatus
|
|
INTEGER,
|
|
sensorProbeHumiditySirenAction
|
|
INTEGER,
|
|
sensorProbeHumidityAcknowledgement
|
|
INTEGER,
|
|
sensorProbeHumiditySirenDelayAlarm
|
|
INTEGER,
|
|
sensorProbeHumidityURL
|
|
DisplayString,
|
|
sensorProbeHumidityOpenURL
|
|
INTEGER,
|
|
sensorProbeHumidityDatacollectType
|
|
INTEGER,
|
|
sensorProbeHumidityContTimeHighCritical
|
|
INTEGER,
|
|
sensorProbeHumidityContTimeHighWarning
|
|
INTEGER,
|
|
sensorProbeHumidityContTimeNormal
|
|
INTEGER,
|
|
sensorProbeHumidityContTimeLowWarning
|
|
INTEGER,
|
|
sensorProbeHumidityContTimeLowCritical
|
|
INTEGER,
|
|
sensorProbeHumidityContTimeSensorError
|
|
INTEGER,
|
|
sensorProbeHumidityCalendar
|
|
INTEGER,
|
|
sensorProbeHumiditySendNormalMail
|
|
INTEGER,
|
|
sensorProbeHumiditySendTrap
|
|
INTEGER,
|
|
sensorProbeHumiditySendMail
|
|
INTEGER
|
|
}
|
|
sensorProbeHumidityDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor"
|
|
::= { sensorProbeHumidityEntry 1 }
|
|
|
|
sensorProbeHumidityLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The physical location of this sensor"
|
|
::= { sensorProbeHumidityEntry 2 }
|
|
|
|
sensorProbeHumidityPercent OBJECT-TYPE
|
|
SYNTAX INTEGER (-32768..32767)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The relative humidity percentage measured by this sensor"
|
|
::= { sensorProbeHumidityEntry 3 }
|
|
|
|
sensorProbeHumidityStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highWarning(3),
|
|
highCritical(4),
|
|
lowWarning(5),
|
|
lowCritical(6),
|
|
sensorError(7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor"
|
|
::= { sensorProbeHumidityEntry 4 }
|
|
|
|
sensorProbeHumidityOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
offline(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If this Sensor is currently online"
|
|
::= { sensorProbeHumidityEntry 5 }
|
|
|
|
sensorProbeHumidityGoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To put online enter a 1, to take offline enter a 2"
|
|
::= { sensorProbeHumidityEntry 6 }
|
|
|
|
sensorProbeHumidityHighWarning OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How high the relative humidity this sensor measures before it sends a warning"
|
|
::= { sensorProbeHumidityEntry 7 }
|
|
|
|
sensorProbeHumidityHighCritical OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How high the relative humidity this sensor measures before it becomes critical"
|
|
::= { sensorProbeHumidityEntry 8 }
|
|
|
|
sensorProbeHumidityLowWarning OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How low the relative humidity this sensor measures before it sends a warning"
|
|
::= { sensorProbeHumidityEntry 9 }
|
|
|
|
sensorProbeHumidityLowCritical OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How low the relative humidity this sensor measures before it becomes critical"
|
|
::= { sensorProbeHumidityEntry 10 }
|
|
|
|
sensorProbeHumidityRearm OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The percent relative humidity to rearm the status. For example if status goes from normal to warning, the humidity must go down spAnalogueRearm below warning before the status goes to normal"
|
|
::= { sensorProbeHumidityEntry 11 }
|
|
|
|
sensorProbeHumidityRaw OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unformatted, raw, A/D value in this sensor. Contains more resolution than the formated percentage. This number can go from 0 to 1023 depending on the input voltage"
|
|
::= { sensorProbeHumidityEntry 13 }
|
|
|
|
sensorProbeHumidityLowVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SP Only: The low voltage range for use in AtoD conversion."
|
|
::= { sensorProbeHumidityEntry 14 }
|
|
|
|
sensorProbeHumidityHighVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SP Only: The high voltage range for use in AtoD conversion."
|
|
::= { sensorProbeHumidityEntry 15 }
|
|
|
|
sensorProbeHumidityEmailTrapLimit OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable email/trap limit feature"
|
|
::= { sensorProbeHumidityEntry 17 }
|
|
|
|
sensorProbeHumidityEmailTrapSchedule OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SP Only: Email/trap limit schedule for this sensor"
|
|
::= { sensorProbeHumidityEntry 18 }
|
|
|
|
sensorProbeHumidityEmailTrapInterval OBJECT-TYPE
|
|
SYNTAX INTEGER (0..60)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minimum time between each [email/trap:SP, only trap:CP8] (can be from 0 to 60 minutes)"
|
|
::= { sensorProbeHumidityEntry 19 }
|
|
|
|
sensorProbeHumiditySendNormalTrap OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable sending email/trap when sensor goes to normal"
|
|
::= { sensorProbeHumidityEntry 20 }
|
|
|
|
sensorProbeHumidityDelayError OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time in seconds after the sensor has been in error status before report as an error"
|
|
::= { sensorProbeHumidityEntry 21 }
|
|
|
|
sensorProbeHumidityDelayNormal OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time in seconds after the sensor change from error to normal before report as normal"
|
|
::= { sensorProbeHumidityEntry 22 }
|
|
|
|
sensorProbeHumidityIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..7)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index into the Humidity sensor table"
|
|
::= { sensorProbeHumidityEntry 23 }
|
|
|
|
sensorProbeHumidityAtoDAmountMaxVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum scale of DC voltage conversion."
|
|
::= { sensorProbeHumidityEntry 24 }
|
|
|
|
sensorProbeHumidityAtoDAmountBaseVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The base scale of DC voltage conversion."
|
|
::= { sensorProbeHumidityEntry 25 }
|
|
|
|
sensorProbeHumidityAtoDTypeUnit OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
absolute(1),
|
|
percent(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Type of scale for use in DC voltage conversion."
|
|
::= { sensorProbeHumidityEntry 26 }
|
|
|
|
sensorProbeHumidityDcUnit OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Display unit in DC voltage conversion."
|
|
::= { sensorProbeHumidityEntry 27 }
|
|
|
|
sensorProbeHumidityAtoDJumper OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
jumperAt-60(-600),
|
|
jumperAt-40(-400),
|
|
jumperAt-30(-300),
|
|
jumperAt-20(-200),
|
|
jumperAt-10(-100),
|
|
jumperAt10(100),
|
|
jumperAt20(200),
|
|
jumperAt30(300),
|
|
jumperAt40(400),
|
|
jumperAt60(600)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selected voltage scale (jumper 0) in DC voltage conversion."
|
|
::= { sensorProbeHumidityEntry 28 }
|
|
|
|
sensorProbeHumidityRelayCycleTime OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Relay toggle period in seconds for Cycle action."
|
|
::= { sensorProbeHumidityEntry 29 }
|
|
|
|
sensorProbeHumidityRelayOnPort OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The sensor port that the relay will listen to. If this is set to 255, then the relay will not listen to any sensor ports"
|
|
::= { sensorProbeHumidityEntry 30 }
|
|
|
|
sensorProbeHumidityRelayActiveStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
highWarning(3),
|
|
highCritical(4),
|
|
lowWarning(5),
|
|
lowCritical(6),
|
|
anyError(7)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor status that will activate the relay"
|
|
::= { sensorProbeHumidityEntry 31 }
|
|
|
|
sensorProbeHumidityRelayAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cycle(2),
|
|
turn-on(3),
|
|
turn-off(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"What the relay will do when the listened to port status turns to the specified active status."
|
|
::= { sensorProbeHumidityEntry 32 }
|
|
|
|
sensorProbeHumidityEmailInterval OBJECT-TYPE
|
|
SYNTAX INTEGER (0..60)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"CP8 Only: Minimum time between each emial (can be from 0 to 60 minutes)"
|
|
::= { sensorProbeHumidityEntry 33 }
|
|
|
|
sensorProbeHumidity4to20mAUnit OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Display unit in DC voltage conversion."
|
|
::= { sensorProbeHumidityEntry 34 }
|
|
|
|
sensorProbeHumidityIndexCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of Humidity sensor online"
|
|
::= { sensorProbeHumidityEntry 35 }
|
|
|
|
sensorProbeHumidityOffset OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Humidity Offset reading"
|
|
::= { sensorProbeHumidityEntry 36 }
|
|
|
|
sensorProbeHumiditySirenCycleTime OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Siren toggle period in seconds for Cycle action."
|
|
::= { sensorProbeHumidityEntry 37 }
|
|
|
|
sensorProbeHumiditySirenOnPort OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The sensor port that the siren will listen to. If this is set to 255, then the siren will not listen to any sensor ports"
|
|
::= { sensorProbeHumidityEntry 38 }
|
|
|
|
sensorProbeHumiditySirenActiveStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
highWarning(3),
|
|
highCritical(4),
|
|
lowWarning(5),
|
|
lowCritical(6),
|
|
anyError(7)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor status that will activate the siren"
|
|
::= { sensorProbeHumidityEntry 39 }
|
|
|
|
sensorProbeHumiditySirenAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cycle(2),
|
|
turn-on(3),
|
|
turn-off(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"What the siren will do when the listened to port status turns to the specified active status."
|
|
::= { sensorProbeHumidityEntry 40 }
|
|
|
|
sensorProbeHumidityAcknowledgement OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ack(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Acknowledged sensor error and stop notification"
|
|
::= { sensorProbeHumidityEntry 41 }
|
|
|
|
sensorProbeHumiditySirenDelayAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Siren delay in seconds before start Alarm."
|
|
::= { sensorProbeHumidityEntry 42 }
|
|
|
|
sensorProbeHumidityURL OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor URL link."
|
|
::= { sensorProbeHumidityEntry 43 }
|
|
|
|
sensorProbeHumidityOpenURL OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cur-window(0),
|
|
new-window(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Open URL in this browser or open in a new window."
|
|
::= { sensorProbeHumidityEntry 44 }
|
|
|
|
sensorProbeHumidityDatacollectType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
average(1),
|
|
highest(2),
|
|
lowest(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Type of datacollect to collect."
|
|
::= { sensorProbeHumidityEntry 45 }
|
|
|
|
sensorProbeHumidityContTimeHighCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in High Critical before accepting new Status."
|
|
::= { sensorProbeHumidityEntry 46 }
|
|
|
|
sensorProbeHumidityContTimeHighWarning OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in High Warning before accepting new Status."
|
|
::= { sensorProbeHumidityEntry 47 }
|
|
|
|
sensorProbeHumidityContTimeNormal OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Normal before accepting new Status."
|
|
::= { sensorProbeHumidityEntry 48 }
|
|
|
|
sensorProbeHumidityContTimeLowWarning OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Low Warning before accepting new Status."
|
|
::= { sensorProbeHumidityEntry 49 }
|
|
|
|
sensorProbeHumidityContTimeLowCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Low Critical before accepting new Status."
|
|
::= { sensorProbeHumidityEntry 50 }
|
|
|
|
sensorProbeHumidityContTimeSensorError OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Sensor Error before accepting new Status."
|
|
::= { sensorProbeHumidityEntry 51 }
|
|
|
|
sensorProbeHumidityCalendar OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable the calendar filtering working hours of sensor."
|
|
::= { sensorProbeHumidityEntry 52 }
|
|
|
|
sensorProbeHumiditySendNormalMail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable sending email when sensor goes to normal"
|
|
::= { sensorProbeHumidityEntry 53 }
|
|
|
|
sensorProbeHumiditySendTrap OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable sending trap when sensor change status"
|
|
::= { sensorProbeHumidityEntry 54 }
|
|
|
|
sensorProbeHumiditySendMail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable sending email when sensor change status"
|
|
::= { sensorProbeHumidityEntry 55 }
|
|
|
|
sensorProbeSwitchTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorProbeSwitchEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the data for every Switch Sensor in the SensorArray. Each row in the table contains data for a different Switch Sensor."
|
|
::= { sensorProbeEntry 18 }
|
|
|
|
sensorProbeSwitchEntry OBJECT-TYPE
|
|
SYNTAX SensorProbeSwitchEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorProbeSwitchEntry Table"
|
|
INDEX { sensorProbeSwitchIndex }
|
|
::= { sensorProbeSwitchTable 1 }
|
|
|
|
SensorProbeSwitchEntry ::= SEQUENCE {
|
|
sensorProbeSwitchDescription
|
|
DisplayString,
|
|
sensorProbeSwitchLocation
|
|
DisplayString,
|
|
sensorProbeSwitchStatus
|
|
INTEGER,
|
|
sensorProbeSwitchOnline
|
|
INTEGER,
|
|
sensorProbeSwitchGoOnline
|
|
INTEGER,
|
|
sensorProbeSwitchDirection
|
|
INTEGER,
|
|
sensorProbeSwitchNormalState
|
|
INTEGER,
|
|
sensorProbeSwitchOutputLevel
|
|
INTEGER,
|
|
sensorProbeSensorType
|
|
INTEGER,
|
|
sensorProbeSwitchEmailTrapLimit
|
|
INTEGER,
|
|
sensorProbeSwitchEmailTrapSchedule
|
|
DisplayString,
|
|
sensorProbeSwitchEmailTrapInterval
|
|
INTEGER,
|
|
sensorProbeSwitchSendNormalTrap
|
|
INTEGER,
|
|
sensorProbeSwitchDelayError
|
|
INTEGER,
|
|
sensorProbeSwitchDelayNormal
|
|
INTEGER,
|
|
sensorProbeSwitchIndex
|
|
INTEGER,
|
|
sensorProbeSwitchRelayCycleTime
|
|
INTEGER,
|
|
sensorProbeSwitchRelayOnPort
|
|
INTEGER,
|
|
sensorProbeSwitchRelayActiveStatus
|
|
INTEGER,
|
|
sensorProbeSwitchRelayAction
|
|
INTEGER,
|
|
sensorProbeSwitchEmailInterval
|
|
INTEGER,
|
|
sensorProbeSwitchRelayOutputVoltStatus
|
|
INTEGER,
|
|
sensorProbeSwitchManualRelayCycleTime
|
|
INTEGER,
|
|
sensorProbeSwitchManualRelayAction
|
|
INTEGER,
|
|
sensorProbeSwitchRelayDescOn
|
|
DisplayString,
|
|
sensorProbeSwitchRelayDescOff
|
|
DisplayString,
|
|
sensorProbeSwitchIndexCount
|
|
INTEGER,
|
|
sensorProbeSwitchSirenCycleTime
|
|
INTEGER,
|
|
sensorProbeSwitchSirenOnPort
|
|
INTEGER,
|
|
sensorProbeSwitchSirenActiveStatus
|
|
INTEGER,
|
|
sensorProbeSwitchSirenAction
|
|
INTEGER,
|
|
sensorProbeSwitchAcknowledgement
|
|
INTEGER,
|
|
sensorProbeSwitchSirenDelayAlarm
|
|
INTEGER,
|
|
sensorProbeSwitchURL
|
|
DisplayString,
|
|
sensorProbeSwitchOpenURL
|
|
INTEGER,
|
|
sensorProbeSwitchContTimeHighCritical
|
|
INTEGER,
|
|
sensorProbeSwitchContTimeNormal
|
|
INTEGER,
|
|
sensorProbeSwitchCalendar
|
|
INTEGER,
|
|
sensorProbeSwitchRelayControlMode
|
|
INTEGER,
|
|
sensorProbeSwitchSirenControlMode
|
|
INTEGER,
|
|
sensorProbeSwitchSendNormalMail
|
|
INTEGER,
|
|
sensorProbeSwitchSendTrap
|
|
INTEGER,
|
|
sensorProbeSwitchSendMail
|
|
INTEGER,
|
|
sensorProbeSwitchWaterRopeLeakLocation
|
|
INTEGER,
|
|
sensorProbeSwitchWaterRopeLength
|
|
INTEGER,
|
|
sensorProbeSwitchWaterRopeUnit
|
|
INTEGER,
|
|
sensorProbeSwitchWaterRopeImpedance
|
|
INTEGER,
|
|
sensorProbeSwitchWaterRopeRaw
|
|
INTEGER,
|
|
sensorProbeSwitchWaterRopeType
|
|
INTEGER
|
|
}
|
|
sensorProbeSwitchDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor Switch"
|
|
::= { sensorProbeSwitchEntry 1 }
|
|
|
|
sensorProbeSwitchLocation OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The physical location of this sensor Switch"
|
|
::= { sensorProbeSwitchEntry 2 }
|
|
|
|
sensorProbeSwitchStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highCritical(4),
|
|
lowCritical(6),
|
|
sensorError(7),
|
|
relayOn(8),
|
|
relayOff(9)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor, only input switches have a status"
|
|
::= { sensorProbeSwitchEntry 3 }
|
|
|
|
sensorProbeSwitchOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
offline(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If this Sensor is currently online"
|
|
::= { sensorProbeSwitchEntry 4 }
|
|
|
|
sensorProbeSwitchGoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To put online enter a 1, to take offline enter a 2"
|
|
::= { sensorProbeSwitchEntry 5 }
|
|
|
|
sensorProbeSwitchDirection OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
input(0),
|
|
output(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To set a switch to input enter 0. To set a switch to output enter 1"
|
|
::= { sensorProbeSwitchEntry 6 }
|
|
|
|
sensorProbeSwitchNormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
closed(0),
|
|
open(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The normal state of an input switch. If an input switch is in this state it is normal, else it is critical. An open switch senses +5 volts. A closed switch senses 0 volts."
|
|
::= { sensorProbeSwitchEntry 7 }
|
|
|
|
sensorProbeSwitchOutputLevel OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low(0),
|
|
high(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An output swith can be set to this level"
|
|
::= { sensorProbeSwitchEntry 8 }
|
|
|
|
sensorProbeSensorType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
temperature(1),
|
|
fourTo20mA(2),
|
|
humidity(3),
|
|
water(4),
|
|
atod(5),
|
|
security(6),
|
|
airflow(8),
|
|
siren(9),
|
|
dryContact(10),
|
|
voltage(12),
|
|
relay(13),
|
|
motion(14)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enter the type of this Sensor"
|
|
::= { sensorProbeSwitchEntry 9 }
|
|
|
|
sensorProbeSwitchEmailTrapLimit OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable email/trap limit feature"
|
|
::= { sensorProbeSwitchEntry 11 }
|
|
|
|
sensorProbeSwitchEmailTrapSchedule OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SP Only: Email/trap limit schedule for this sensor"
|
|
::= { sensorProbeSwitchEntry 12 }
|
|
|
|
sensorProbeSwitchEmailTrapInterval OBJECT-TYPE
|
|
SYNTAX INTEGER (0..60)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minimum time between each [email/trap:SP, only trap:CP8] (can be from 0 to 60 minutes)"
|
|
::= { sensorProbeSwitchEntry 13 }
|
|
|
|
sensorProbeSwitchSendNormalTrap OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable sending email/trap when sensor goes to normal"
|
|
::= { sensorProbeSwitchEntry 14 }
|
|
|
|
sensorProbeSwitchDelayError OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time in seconds after the sensor has been in error status before report as an error"
|
|
::= { sensorProbeSwitchEntry 15 }
|
|
|
|
sensorProbeSwitchDelayNormal OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time in seconds after the sensor change from error to normal before report as normal"
|
|
::= { sensorProbeSwitchEntry 16 }
|
|
|
|
sensorProbeSwitchIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..67)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index into the Switch sensor table"
|
|
::= { sensorProbeSwitchEntry 17 }
|
|
|
|
sensorProbeSwitchRelayCycleTime OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Relay toggle period in seconds for Cycle action."
|
|
::= { sensorProbeSwitchEntry 18 }
|
|
|
|
sensorProbeSwitchRelayOnPort OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The sensor port that the relay will listen to. If this is set to 255, then the relay will not listen to any sensor ports"
|
|
::= { sensorProbeSwitchEntry 19 }
|
|
|
|
sensorProbeSwitchRelayActiveStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
highWarning(3),
|
|
highCritical(4),
|
|
lowWarning(5),
|
|
lowCritical(6),
|
|
anyError(7)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor status that will activate the relay"
|
|
::= { sensorProbeSwitchEntry 20 }
|
|
|
|
sensorProbeSwitchRelayAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cycle(2),
|
|
turn-on(3),
|
|
turn-off(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"What the relay will do when the listened to port status turns to the specified active status."
|
|
::= { sensorProbeSwitchEntry 21 }
|
|
|
|
sensorProbeSwitchEmailInterval OBJECT-TYPE
|
|
SYNTAX INTEGER (0..60)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"CP8 Only: Minimum time between each email (can be from 0 to 60 minutes)"
|
|
::= { sensorProbeSwitchEntry 22 }
|
|
|
|
sensorProbeSwitchRelayOutputVoltStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
sensorError(7),
|
|
noVoltagePresent(10),
|
|
voltagePresent(11)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SP Only: The current voltage status of the relay"
|
|
::= { sensorProbeSwitchEntry 23 }
|
|
|
|
sensorProbeSwitchManualRelayCycleTime OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Relay toggle period in seconds for Manual Cycle action."
|
|
::= { sensorProbeSwitchEntry 24 }
|
|
|
|
sensorProbeSwitchManualRelayAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
allow-sensor-control(1),
|
|
turn-on(3),
|
|
turn-off(4),
|
|
cycle-Off-On-Off(7),
|
|
cycle-On-Off-On(8)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Control the relay manualy"
|
|
::= { sensorProbeSwitchEntry 25 }
|
|
|
|
sensorProbeSwitchRelayDescOn OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of relay On"
|
|
::= { sensorProbeSwitchEntry 26 }
|
|
|
|
sensorProbeSwitchRelayDescOff OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of relay Off"
|
|
::= { sensorProbeSwitchEntry 27 }
|
|
|
|
sensorProbeSwitchIndexCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of Switch sensor online"
|
|
::= { sensorProbeSwitchEntry 28 }
|
|
|
|
sensorProbeSwitchSirenCycleTime OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Siren toggle period in seconds for Cycle action."
|
|
::= { sensorProbeSwitchEntry 29 }
|
|
|
|
sensorProbeSwitchSirenOnPort OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The sensor port that the siren will listen to. If this is set to 255, then the siren will not listen to any sensor ports"
|
|
::= { sensorProbeSwitchEntry 30 }
|
|
|
|
sensorProbeSwitchSirenActiveStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
highWarning(3),
|
|
highCritical(4),
|
|
lowWarning(5),
|
|
lowCritical(6),
|
|
anyError(7)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor status that will activate the siren"
|
|
::= { sensorProbeSwitchEntry 31 }
|
|
|
|
sensorProbeSwitchSirenAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cycle(2),
|
|
turn-on(3),
|
|
turn-off(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"What the siren will do when the listened to port status turns to the specified active status."
|
|
::= { sensorProbeSwitchEntry 32 }
|
|
|
|
sensorProbeSwitchAcknowledgement OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ack(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Acknowledged sensor error and stop notification"
|
|
::= { sensorProbeSwitchEntry 33 }
|
|
|
|
sensorProbeSwitchSirenDelayAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Siren delay in seconds before start Alarm."
|
|
::= { sensorProbeSwitchEntry 34 }
|
|
|
|
sensorProbeSwitchURL OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor URL link."
|
|
::= { sensorProbeSwitchEntry 35 }
|
|
|
|
sensorProbeSwitchOpenURL OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cur-window(0),
|
|
new-window(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Open URL in this browser or open in a new window."
|
|
::= { sensorProbeSwitchEntry 36 }
|
|
|
|
sensorProbeSwitchContTimeHighCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in High Critical before accepting new Status."
|
|
::= { sensorProbeSwitchEntry 37 }
|
|
|
|
sensorProbeSwitchContTimeNormal OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Normal before accepting new Status."
|
|
::= { sensorProbeSwitchEntry 39 }
|
|
|
|
sensorProbeSwitchCalendar OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable the calendar filtering working hours of sensor."
|
|
::= { sensorProbeSwitchEntry 43 }
|
|
|
|
sensorProbeSwitchRelayControlMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
manual-control(0),
|
|
notification-control(1),
|
|
time-control(2),
|
|
thermostat-control(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Relay Control Mode used for selecting the mode to control a relay."
|
|
::= { sensorProbeSwitchEntry 44 }
|
|
|
|
sensorProbeSwitchSirenControlMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
manual-control(0),
|
|
notification-control(1),
|
|
time-control(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Siren Control Mode used for selecting the mode to control a siren."
|
|
::= { sensorProbeSwitchEntry 45 }
|
|
|
|
sensorProbeSwitchSendNormalMail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable sending email when sensor goes to normal"
|
|
::= { sensorProbeSwitchEntry 46 }
|
|
|
|
sensorProbeSwitchSendTrap OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable sending trap when sensor change status"
|
|
::= { sensorProbeSwitchEntry 47 }
|
|
|
|
sensorProbeSwitchSendMail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable sending email when sensor change status"
|
|
::= { sensorProbeSwitchEntry 48 }
|
|
|
|
sensorProbeSwitchWaterRopeLeakLocation OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Location of leakage of water rope sensor."
|
|
::= { sensorProbeSwitchEntry 49 }
|
|
|
|
sensorProbeSwitchWaterRopeLength OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Length of water rope sensor."
|
|
::= { sensorProbeSwitchEntry 50 }
|
|
|
|
sensorProbeSwitchWaterRopeUnit OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
meters(0),
|
|
feet(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Display unit of water rope sensor."
|
|
::= { sensorProbeSwitchEntry 51 }
|
|
|
|
sensorProbeSwitchWaterRopeImpedance OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensing wire impedance per meter value times 100"
|
|
::= { sensorProbeSwitchEntry 52 }
|
|
|
|
sensorProbeSwitchWaterRopeRaw OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Raw value of location or length in ohms"
|
|
::= { sensorProbeSwitchEntry 53 }
|
|
|
|
sensorProbeSwitchWaterRopeType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
custom(0),
|
|
water(1),
|
|
fuel(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Water rope sensing cable type"
|
|
::= { sensorProbeSwitchEntry 55 }
|
|
|
|
sensorProbeOtherSensor OBJECT IDENTIFIER ::= { sensorProbeEntry 19 }
|
|
|
|
sensorProbeIRMSSensor OBJECT IDENTIFIER ::= { sensorProbeOtherSensor 26 }
|
|
|
|
sensorProbeIRMSSensorNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of RMS current Sensor port."
|
|
::= { sensorProbeIRMSSensor 1 }
|
|
|
|
sensorProbeIRMSSensorTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorProbeIRMSSensorEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the data for every RMS current Sensor in the SensorArray. Each row in the table contains data for a different RMS current Sensor."
|
|
::= { sensorProbeIRMSSensor 2 }
|
|
|
|
sensorProbeIRMSSensorEntry OBJECT-TYPE
|
|
SYNTAX SensorProbeIRMSSensorEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorProbeIRMSSensorEntry Table"
|
|
INDEX { sensorProbeIRMSSensorIndex }
|
|
::= { sensorProbeIRMSSensorTable 1 }
|
|
|
|
SensorProbeIRMSSensorEntry ::= SEQUENCE {
|
|
sensorProbeIRMSSensorIndex
|
|
INTEGER,
|
|
sensorProbeIRMSDescription
|
|
DisplayString,
|
|
sensorProbeIRMSPercent
|
|
INTEGER,
|
|
sensorProbeIRMSStatus
|
|
INTEGER,
|
|
sensorProbeIRMSOnline
|
|
INTEGER,
|
|
sensorProbeIRMSGoOnline
|
|
INTEGER,
|
|
sensorProbeIRMSHighWarning
|
|
INTEGER,
|
|
sensorProbeIRMSHighCritical
|
|
INTEGER,
|
|
sensorProbeIRMSLowWarning
|
|
INTEGER,
|
|
sensorProbeIRMSLowCritical
|
|
INTEGER,
|
|
sensorProbeIRMSRearm
|
|
INTEGER,
|
|
sensorProbeIRMSRaw
|
|
INTEGER,
|
|
sensorProbeIRMSEmailTrapLimit
|
|
INTEGER,
|
|
sensorProbeIRMSDelayError
|
|
INTEGER,
|
|
sensorProbeIRMSDelayNormal
|
|
INTEGER,
|
|
sensorProbeIRMSRelayCycleTime
|
|
INTEGER,
|
|
sensorProbeIRMSRelayOnPort
|
|
INTEGER,
|
|
sensorProbeIRMSRelayActiveStatus
|
|
INTEGER,
|
|
sensorProbeIRMSRelayAction
|
|
INTEGER,
|
|
sensorProbeIRMSSirenCycleTime
|
|
INTEGER,
|
|
sensorProbeIRMSSirenOnPort
|
|
INTEGER,
|
|
sensorProbeIRMSSirenActiveStatus
|
|
INTEGER,
|
|
sensorProbeIRMSSirenAction
|
|
INTEGER,
|
|
sensorProbeIRMSAcknowledgement
|
|
INTEGER,
|
|
sensorProbeIRMSSirenDelayAlarm
|
|
INTEGER,
|
|
sensorProbeIRMSURL
|
|
DisplayString,
|
|
sensorProbeIRMSOpenURL
|
|
INTEGER,
|
|
sensorProbeIRMSDatacollectType
|
|
INTEGER,
|
|
sensorProbeIRMSContTimeHighCritical
|
|
INTEGER,
|
|
sensorProbeIRMSContTimeHighWarning
|
|
INTEGER,
|
|
sensorProbeIRMSContTimeNormal
|
|
INTEGER,
|
|
sensorProbeIRMSContTimeLowWarning
|
|
INTEGER,
|
|
sensorProbeIRMSContTimeLowCritical
|
|
INTEGER,
|
|
sensorProbeIRMSContTimeSensorError
|
|
INTEGER,
|
|
sensorProbeIRMSCalendar
|
|
INTEGER
|
|
}
|
|
|
|
sensorProbeIRMSSensorIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..7)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value for each IRMS sensor port."
|
|
::= { sensorProbeIRMSSensorEntry 1 }
|
|
|
|
sensorProbeIRMSDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor IRMS"
|
|
::= { sensorProbeIRMSSensorEntry 2 }
|
|
|
|
sensorProbeIRMSPercent OBJECT-TYPE
|
|
SYNTAX INTEGER (-32768..32767)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The relative IRMS percentage measured by this sensor"
|
|
::= { sensorProbeIRMSSensorEntry 3 }
|
|
|
|
sensorProbeIRMSStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highWarning(3),
|
|
highCritical(4),
|
|
lowWarning(5),
|
|
lowCritical(6),
|
|
sensorError(7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor"
|
|
::= { sensorProbeIRMSSensorEntry 4 }
|
|
|
|
sensorProbeIRMSOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
offline(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If this Sensor is currently online"
|
|
::= { sensorProbeIRMSSensorEntry 5 }
|
|
|
|
sensorProbeIRMSGoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To put online enter a 1, to take offline enter a 2"
|
|
::= { sensorProbeIRMSSensorEntry 6 }
|
|
|
|
sensorProbeIRMSHighWarning OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How high the relative IRMS this sensor measures before it sends a warning"
|
|
::= { sensorProbeIRMSSensorEntry 7 }
|
|
|
|
sensorProbeIRMSHighCritical OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How high the relative IRMS this sensor measures before it becomes critical"
|
|
::= { sensorProbeIRMSSensorEntry 8 }
|
|
|
|
sensorProbeIRMSLowWarning OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How low the relative IRMS this sensor measures before it sends a warning"
|
|
::= { sensorProbeIRMSSensorEntry 9 }
|
|
|
|
sensorProbeIRMSLowCritical OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How low the relative IRMS this sensor measures before it becomes critical"
|
|
::= { sensorProbeIRMSSensorEntry 10 }
|
|
|
|
sensorProbeIRMSRearm OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The percent relative IRMS to rearm the status. For example if status goes from normal to warning, the IRMS must go down spAnalogueRearm below warning before the status goes to normal"
|
|
::= { sensorProbeIRMSSensorEntry 11 }
|
|
|
|
sensorProbeIRMSRaw OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unformatted, raw, A/D value in this sensor. Contains more resolution than the formated percentage. This number can go from 0 to 1023 depending on the input voltage"
|
|
::= { sensorProbeIRMSSensorEntry 13 }
|
|
|
|
sensorProbeIRMSEmailTrapLimit OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable email/trap limit feature"
|
|
::= { sensorProbeIRMSSensorEntry 17 }
|
|
|
|
sensorProbeIRMSDelayError OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time in seconds after the sensor has been in error status before report as an error"
|
|
::= { sensorProbeIRMSSensorEntry 21 }
|
|
|
|
sensorProbeIRMSDelayNormal OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time in seconds after the sensor change from error to normal before report as normal"
|
|
::= { sensorProbeIRMSSensorEntry 22 }
|
|
|
|
sensorProbeIRMSRelayCycleTime OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Relay toggle period in seconds for Cycle action."
|
|
::= { sensorProbeIRMSSensorEntry 29 }
|
|
|
|
sensorProbeIRMSRelayOnPort OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The sensor port that the relay will listen to. If this is set to 255, then the relay will not listen to any sensor ports"
|
|
::= { sensorProbeIRMSSensorEntry 30 }
|
|
|
|
sensorProbeIRMSRelayActiveStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
highWarning(3),
|
|
highCritical(4),
|
|
lowWarning(5),
|
|
lowCritical(6),
|
|
anyError(7)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor status that will activate the relay"
|
|
::= { sensorProbeIRMSSensorEntry 31 }
|
|
|
|
sensorProbeIRMSRelayAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cycle(2),
|
|
turn-on(3),
|
|
turn-off(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"What the relay will do when the listened to port status turns to the specified active status."
|
|
::= { sensorProbeIRMSSensorEntry 32 }
|
|
|
|
sensorProbeIRMSSirenCycleTime OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Siren toggle period in seconds for Cycle action."
|
|
::= { sensorProbeIRMSSensorEntry 37 }
|
|
|
|
sensorProbeIRMSSirenOnPort OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The sensor port that the siren will listen to. If this is set to 255, then the siren will not listen to any sensor ports"
|
|
::= { sensorProbeIRMSSensorEntry 38 }
|
|
|
|
sensorProbeIRMSSirenActiveStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
highWarning(3),
|
|
highCritical(4),
|
|
lowWarning(5),
|
|
lowCritical(6),
|
|
anyError(7)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor status that will activate the siren"
|
|
::= { sensorProbeIRMSSensorEntry 39 }
|
|
|
|
sensorProbeIRMSSirenAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cycle(2),
|
|
turn-on(3),
|
|
turn-off(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"What the siren will do when the listened to port status turns to the specified active status."
|
|
::= { sensorProbeIRMSSensorEntry 40 }
|
|
|
|
sensorProbeIRMSAcknowledgement OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ack(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Acknowledged sensor error and stop notification"
|
|
::= { sensorProbeIRMSSensorEntry 41 }
|
|
|
|
sensorProbeIRMSSirenDelayAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Siren delay in seconds before start Alarm."
|
|
::= { sensorProbeIRMSSensorEntry 42 }
|
|
|
|
sensorProbeIRMSURL OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor URL link."
|
|
::= { sensorProbeIRMSSensorEntry 43 }
|
|
|
|
sensorProbeIRMSOpenURL OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cur-window(0),
|
|
new-window(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Open URL in this browser or open in a new window."
|
|
::= { sensorProbeIRMSSensorEntry 44 }
|
|
|
|
sensorProbeIRMSDatacollectType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
average(1),
|
|
highest(2),
|
|
lowest(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Type of datacollect to collect."
|
|
::= { sensorProbeIRMSSensorEntry 45 }
|
|
|
|
sensorProbeIRMSContTimeHighCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in High Critical before accepting new Status."
|
|
::= { sensorProbeIRMSSensorEntry 46 }
|
|
|
|
sensorProbeIRMSContTimeHighWarning OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in High Warning before accepting new Status."
|
|
::= { sensorProbeIRMSSensorEntry 47 }
|
|
|
|
sensorProbeIRMSContTimeNormal OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Normal before accepting new Status."
|
|
::= { sensorProbeIRMSSensorEntry 48 }
|
|
|
|
sensorProbeIRMSContTimeLowWarning OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Low Warning before accepting new Status."
|
|
::= { sensorProbeIRMSSensorEntry 49 }
|
|
|
|
sensorProbeIRMSContTimeLowCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Low Critical before accepting new Status."
|
|
::= { sensorProbeIRMSSensorEntry 50 }
|
|
|
|
sensorProbeIRMSContTimeSensorError OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Sensor Error before accepting new Status."
|
|
::= { sensorProbeIRMSSensorEntry 51 }
|
|
|
|
sensorProbeIRMSCalendar OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable the calendar filtering working hours of sensor."
|
|
::= { sensorProbeIRMSSensorEntry 52 }
|
|
|
|
sensorProbeVRMSSensor OBJECT IDENTIFIER ::= { sensorProbeOtherSensor 27 }
|
|
|
|
sensorProbeVRMSSensorNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of RMS voltage Sensor port."
|
|
::= { sensorProbeVRMSSensor 1 }
|
|
|
|
sensorProbeVRMSSensorTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorProbeVRMSSensorEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the data for every RMS voltage Sensor in the SensorArray. Each row in the table contains data for a different RMS voltage Sensor."
|
|
::= { sensorProbeVRMSSensor 2 }
|
|
|
|
sensorProbeVRMSSensorEntry OBJECT-TYPE
|
|
SYNTAX SensorProbeVRMSSensorEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorProbeVRMSSensorEntry Table"
|
|
INDEX { sensorProbeVRMSSensorIndex }
|
|
::= { sensorProbeVRMSSensorTable 1 }
|
|
|
|
SensorProbeVRMSSensorEntry ::= SEQUENCE {
|
|
sensorProbeVRMSSensorIndex
|
|
INTEGER,
|
|
sensorProbeVRMSDescription
|
|
DisplayString,
|
|
sensorProbeVRMSPercent
|
|
INTEGER,
|
|
sensorProbeVRMSStatus
|
|
INTEGER,
|
|
sensorProbeVRMSOnline
|
|
INTEGER,
|
|
sensorProbeVRMSGoOnline
|
|
INTEGER,
|
|
sensorProbeVRMSHighWarning
|
|
INTEGER,
|
|
sensorProbeVRMSHighCritical
|
|
INTEGER,
|
|
sensorProbeVRMSLowWarning
|
|
INTEGER,
|
|
sensorProbeVRMSLowCritical
|
|
INTEGER,
|
|
sensorProbeVRMSRearm
|
|
INTEGER,
|
|
sensorProbeVRMSRaw
|
|
INTEGER,
|
|
sensorProbeVRMSEmailTrapLimit
|
|
INTEGER,
|
|
sensorProbeVRMSDelayError
|
|
INTEGER,
|
|
sensorProbeVRMSDelayNormal
|
|
INTEGER,
|
|
sensorProbeVRMSRelayCycleTime
|
|
INTEGER,
|
|
sensorProbeVRMSRelayOnPort
|
|
INTEGER,
|
|
sensorProbeVRMSRelayActiveStatus
|
|
INTEGER,
|
|
sensorProbeVRMSRelayAction
|
|
INTEGER,
|
|
sensorProbeVRMSSirenCycleTime
|
|
INTEGER,
|
|
sensorProbeVRMSSirenOnPort
|
|
INTEGER,
|
|
sensorProbeVRMSSirenActiveStatus
|
|
INTEGER,
|
|
sensorProbeVRMSSirenAction
|
|
INTEGER,
|
|
sensorProbeVRMSAcknowledgement
|
|
INTEGER,
|
|
sensorProbeVRMSSirenDelayAlarm
|
|
INTEGER,
|
|
sensorProbeVRMSvoltageMode
|
|
INTEGER,
|
|
sensorProbeVRMSURL
|
|
DisplayString,
|
|
sensorProbeVRMSOpenURL
|
|
INTEGER,
|
|
sensorProbeVRMSDatacollectType
|
|
INTEGER,
|
|
sensorProbeVRMSContTimeHighCritical
|
|
INTEGER,
|
|
sensorProbeVRMSContTimeHighWarning
|
|
INTEGER,
|
|
sensorProbeVRMSContTimeNormal
|
|
INTEGER,
|
|
sensorProbeVRMSContTimeLowWarning
|
|
INTEGER,
|
|
sensorProbeVRMSContTimeLowCritical
|
|
INTEGER,
|
|
sensorProbeVRMSContTimeSensorError
|
|
INTEGER,
|
|
sensorProbeVRMSCalendar
|
|
INTEGER
|
|
}
|
|
|
|
sensorProbeVRMSSensorIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..7)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value for each VRMS sensor port."
|
|
::= { sensorProbeVRMSSensorEntry 1 }
|
|
|
|
sensorProbeVRMSDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor VRMS"
|
|
::= { sensorProbeVRMSSensorEntry 2 }
|
|
|
|
sensorProbeVRMSPercent OBJECT-TYPE
|
|
SYNTAX INTEGER (-32768..32767)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The relative VRMS percentage measured by this sensor"
|
|
::= { sensorProbeVRMSSensorEntry 3 }
|
|
|
|
sensorProbeVRMSStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highWarning(3),
|
|
highCritical(4),
|
|
lowWarning(5),
|
|
lowCritical(6),
|
|
sensorError(7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor"
|
|
::= { sensorProbeVRMSSensorEntry 4 }
|
|
|
|
sensorProbeVRMSOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
offline(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If this Sensor is currently online"
|
|
::= { sensorProbeVRMSSensorEntry 5 }
|
|
|
|
sensorProbeVRMSGoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To put online enter a 1, to take offline enter a 2"
|
|
::= { sensorProbeVRMSSensorEntry 6 }
|
|
|
|
sensorProbeVRMSHighWarning OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How high the relative VRMS this sensor measures before it sends a warning"
|
|
::= { sensorProbeVRMSSensorEntry 7 }
|
|
|
|
sensorProbeVRMSHighCritical OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How high the relative VRMS this sensor measures before it becomes critical"
|
|
::= { sensorProbeVRMSSensorEntry 8 }
|
|
|
|
sensorProbeVRMSLowWarning OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How low the relative VRMS this sensor measures before it sends a warning"
|
|
::= { sensorProbeVRMSSensorEntry 9 }
|
|
|
|
sensorProbeVRMSLowCritical OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How low the relative VRMS this sensor measures before it becomes critical"
|
|
::= { sensorProbeVRMSSensorEntry 10 }
|
|
|
|
sensorProbeVRMSRearm OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The percent relative VRMS to rearm the status. For example if status goes from normal to warning, the VRMS must go down spAnalogueRearm below warning before the status goes to normal"
|
|
::= { sensorProbeVRMSSensorEntry 11 }
|
|
|
|
sensorProbeVRMSRaw OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unformatted, raw, A/D value in this sensor. Contains more resolution than the formated percentage. This number can go from 0 to 1023 depending on the input voltage"
|
|
::= { sensorProbeVRMSSensorEntry 13 }
|
|
|
|
sensorProbeVRMSEmailTrapLimit OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable email/trap limit feature"
|
|
::= { sensorProbeVRMSSensorEntry 17 }
|
|
|
|
sensorProbeVRMSDelayError OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time in seconds after the sensor has been in error status before report as an error"
|
|
::= { sensorProbeVRMSSensorEntry 21 }
|
|
|
|
sensorProbeVRMSDelayNormal OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time in seconds after the sensor change from error to normal before report as normal"
|
|
::= { sensorProbeVRMSSensorEntry 22 }
|
|
|
|
sensorProbeVRMSRelayCycleTime OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Relay toggle period in seconds for Cycle action."
|
|
::= { sensorProbeVRMSSensorEntry 29 }
|
|
|
|
sensorProbeVRMSRelayOnPort OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The sensor port that the relay will listen to. If this is set to 255, then the relay will not listen to any sensor ports"
|
|
::= { sensorProbeVRMSSensorEntry 30 }
|
|
|
|
sensorProbeVRMSRelayActiveStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
highWarning(3),
|
|
highCritical(4),
|
|
lowWarning(5),
|
|
lowCritical(6),
|
|
anyError(7)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor status that will activate the relay"
|
|
::= { sensorProbeVRMSSensorEntry 31 }
|
|
|
|
sensorProbeVRMSRelayAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cycle(2),
|
|
turn-on(3),
|
|
turn-off(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"What the relay will do when the listened to port status turns to the specified active status."
|
|
::= { sensorProbeVRMSSensorEntry 32 }
|
|
|
|
sensorProbeVRMSSirenCycleTime OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Siren toggle period in seconds for Cycle action."
|
|
::= { sensorProbeVRMSSensorEntry 37 }
|
|
|
|
sensorProbeVRMSSirenOnPort OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The sensor port that the siren will listen to. If this is set to 255, then the siren will not listen to any sensor ports"
|
|
::= { sensorProbeVRMSSensorEntry 38 }
|
|
|
|
sensorProbeVRMSSirenActiveStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
highWarning(3),
|
|
highCritical(4),
|
|
lowWarning(5),
|
|
lowCritical(6),
|
|
anyError(7)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor status that will activate the siren"
|
|
::= { sensorProbeVRMSSensorEntry 39 }
|
|
|
|
sensorProbeVRMSSirenAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cycle(2),
|
|
turn-on(3),
|
|
turn-off(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"What the siren will do when the listened to port status turns to the specified active status."
|
|
::= { sensorProbeVRMSSensorEntry 40 }
|
|
|
|
sensorProbeVRMSAcknowledgement OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ack(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Acknowledged sensor error and stop notification"
|
|
::= { sensorProbeVRMSSensorEntry 41 }
|
|
|
|
sensorProbeVRMSSirenDelayAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Siren delay in seconds before start Alarm."
|
|
::= { sensorProbeVRMSSensorEntry 42 }
|
|
|
|
sensorProbeVRMSvoltageMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ac-110(110),
|
|
ac-220(220)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"VRMS Voltage Mode."
|
|
::= { sensorProbeVRMSSensorEntry 43 }
|
|
|
|
sensorProbeVRMSURL OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor URL link."
|
|
::= { sensorProbeVRMSSensorEntry 44 }
|
|
|
|
sensorProbeVRMSOpenURL OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cur-window(0),
|
|
new-window(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Open URL in this browser or open in a new window."
|
|
::= { sensorProbeVRMSSensorEntry 45 }
|
|
|
|
sensorProbeVRMSDatacollectType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
average(1),
|
|
highest(2),
|
|
lowest(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Type of datacollect to collect."
|
|
::= { sensorProbeVRMSSensorEntry 46 }
|
|
|
|
sensorProbeVRMSContTimeHighCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in High Critical before accepting new Status."
|
|
::= { sensorProbeVRMSSensorEntry 47 }
|
|
|
|
sensorProbeVRMSContTimeHighWarning OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in High Warning before accepting new Status."
|
|
::= { sensorProbeVRMSSensorEntry 48 }
|
|
|
|
sensorProbeVRMSContTimeNormal OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Normal before accepting new Status."
|
|
::= { sensorProbeVRMSSensorEntry 49 }
|
|
|
|
sensorProbeVRMSContTimeLowWarning OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Low Warning before accepting new Status."
|
|
::= { sensorProbeVRMSSensorEntry 50 }
|
|
|
|
sensorProbeVRMSContTimeLowCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Low Critical before accepting new Status."
|
|
::= { sensorProbeVRMSSensorEntry 51 }
|
|
|
|
sensorProbeVRMSContTimeSensorError OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Sensor Error before accepting new Status."
|
|
::= { sensorProbeVRMSSensorEntry 52 }
|
|
|
|
sensorProbeVRMSCalendar OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable the calendar filtering working hours of sensor."
|
|
::= { sensorProbeVRMSSensorEntry 53 }
|
|
|
|
sensorProbeEnergySensor OBJECT IDENTIFIER ::= { sensorProbeOtherSensor 28 }
|
|
|
|
sensorProbeEnergySensorNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of Energy Sensor port."
|
|
::= { sensorProbeEnergySensor 1 }
|
|
|
|
sensorProbeEnergySensorTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorProbeEnergySensorEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the data for every Energy Sensor in the SensorArray. Each row in the table contains data for a different Energy Sensor."
|
|
::= { sensorProbeEnergySensor 2 }
|
|
|
|
sensorProbeEnergySensorEntry OBJECT-TYPE
|
|
SYNTAX SensorProbeEnergySensorEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorProbeEnergySensorEntry Table"
|
|
INDEX { sensorProbeEnergySensorIndex }
|
|
::= { sensorProbeEnergySensorTable 1 }
|
|
|
|
SensorProbeEnergySensorEntry ::= SEQUENCE {
|
|
sensorProbeEnergySensorIndex
|
|
INTEGER,
|
|
sensorProbeEnergyDescription
|
|
DisplayString,
|
|
sensorProbeEnergyPercent
|
|
INTEGER,
|
|
sensorProbeEnergyStatus
|
|
INTEGER,
|
|
sensorProbeEnergyOnline
|
|
INTEGER,
|
|
sensorProbeEnergyGoOnline
|
|
INTEGER,
|
|
sensorProbeEnergyHighWarning
|
|
INTEGER,
|
|
sensorProbeEnergyHighCritical
|
|
INTEGER,
|
|
sensorProbeEnergyLowWarning
|
|
INTEGER,
|
|
sensorProbeEnergyLowCritical
|
|
INTEGER,
|
|
sensorProbeEnergyRearm
|
|
INTEGER,
|
|
sensorProbeEnergyRaw
|
|
INTEGER,
|
|
sensorProbeEnergyEmailTrapLimit
|
|
INTEGER,
|
|
sensorProbeEnergyDelayError
|
|
INTEGER,
|
|
sensorProbeEnergyDelayNormal
|
|
INTEGER,
|
|
sensorProbeEnergyRelayCycleTime
|
|
INTEGER,
|
|
sensorProbeEnergyRelayOnPort
|
|
INTEGER,
|
|
sensorProbeEnergyRelayActiveStatus
|
|
INTEGER,
|
|
sensorProbeEnergyRelayAction
|
|
INTEGER,
|
|
sensorProbeEnergySirenCycleTime
|
|
INTEGER,
|
|
sensorProbeEnergySirenOnPort
|
|
INTEGER,
|
|
sensorProbeEnergySirenActiveStatus
|
|
INTEGER,
|
|
sensorProbeEnergySirenAction
|
|
INTEGER,
|
|
sensorProbeEnergyAcknowledgement
|
|
INTEGER,
|
|
sensorProbeEnergySirenDelayAlarm
|
|
INTEGER,
|
|
sensorProbeEnergyReadingMode
|
|
INTEGER,
|
|
sensorProbeEnergyURL
|
|
DisplayString,
|
|
sensorProbeEnergyOpenURL
|
|
INTEGER,
|
|
sensorProbeEnergyDatacollectType
|
|
INTEGER,
|
|
sensorProbeEnergyContTimeHighCritical
|
|
INTEGER,
|
|
sensorProbeEnergyContTimeHighWarning
|
|
INTEGER,
|
|
sensorProbeEnergyContTimeNormal
|
|
INTEGER,
|
|
sensorProbeEnergyContTimeLowWarning
|
|
INTEGER,
|
|
sensorProbeEnergyContTimeLowCritical
|
|
INTEGER,
|
|
sensorProbeEnergyContTimeSensorError
|
|
INTEGER,
|
|
sensorProbeEnergyCalendar
|
|
INTEGER
|
|
}
|
|
|
|
sensorProbeEnergySensorIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..7)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value for each Energy sensor port."
|
|
::= { sensorProbeEnergySensorEntry 1 }
|
|
|
|
sensorProbeEnergyDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor Energy"
|
|
::= { sensorProbeEnergySensorEntry 2 }
|
|
|
|
sensorProbeEnergyPercent OBJECT-TYPE
|
|
SYNTAX INTEGER (-32768..32767)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The relative Energy percentage measured by this sensor"
|
|
::= { sensorProbeEnergySensorEntry 3 }
|
|
|
|
sensorProbeEnergyStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highWarning(3),
|
|
highCritical(4),
|
|
lowWarning(5),
|
|
lowCritical(6),
|
|
sensorError(7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor"
|
|
::= { sensorProbeEnergySensorEntry 4 }
|
|
|
|
sensorProbeEnergyOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
offline(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If this Sensor is currently online"
|
|
::= { sensorProbeEnergySensorEntry 5 }
|
|
|
|
sensorProbeEnergyGoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To put online enter a 1, to take offline enter a 2"
|
|
::= { sensorProbeEnergySensorEntry 6 }
|
|
|
|
sensorProbeEnergyHighWarning OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How high the relative Energy this sensor measures before it sends a warning"
|
|
::= { sensorProbeEnergySensorEntry 7 }
|
|
|
|
sensorProbeEnergyHighCritical OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How high the relative Energy this sensor measures before it becomes critical"
|
|
::= { sensorProbeEnergySensorEntry 8 }
|
|
|
|
sensorProbeEnergyLowWarning OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How low the relative Energy this sensor measures before it sends a warning"
|
|
::= { sensorProbeEnergySensorEntry 9 }
|
|
|
|
sensorProbeEnergyLowCritical OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How low the relative Energy this sensor measures before it becomes critical"
|
|
::= { sensorProbeEnergySensorEntry 10 }
|
|
|
|
sensorProbeEnergyRearm OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The percent relative Energy to rearm the status. For example if status goes from normal to warning, the Energy must go down spAnalogueRearm below warning before the status goes to normal"
|
|
::= { sensorProbeEnergySensorEntry 11 }
|
|
|
|
sensorProbeEnergyRaw OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unformatted, raw, A/D value in this sensor. Contains more resolution than the formated percentage. This number can go from 0 to 1023 depending on the input voltage"
|
|
::= { sensorProbeEnergySensorEntry 13 }
|
|
|
|
sensorProbeEnergyEmailTrapLimit OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable email/trap limit feature"
|
|
::= { sensorProbeEnergySensorEntry 17 }
|
|
|
|
sensorProbeEnergyDelayError OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time in seconds after the sensor has been in error status before report as an error"
|
|
::= { sensorProbeEnergySensorEntry 21 }
|
|
|
|
sensorProbeEnergyDelayNormal OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time in seconds after the sensor change from error to normal before report as normal"
|
|
::= { sensorProbeEnergySensorEntry 22 }
|
|
|
|
sensorProbeEnergyRelayCycleTime OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Relay toggle period in seconds for Cycle action."
|
|
::= { sensorProbeEnergySensorEntry 29 }
|
|
|
|
sensorProbeEnergyRelayOnPort OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The sensor port that the relay will listen to. If this is set to 255, then the relay will not listen to any sensor ports"
|
|
::= { sensorProbeEnergySensorEntry 30 }
|
|
|
|
sensorProbeEnergyRelayActiveStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
highWarning(3),
|
|
highCritical(4),
|
|
lowWarning(5),
|
|
lowCritical(6),
|
|
anyError(7)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor status that will activate the relay"
|
|
::= { sensorProbeEnergySensorEntry 31 }
|
|
|
|
sensorProbeEnergyRelayAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cycle(2),
|
|
turn-on(3),
|
|
turn-off(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"What the relay will do when the listened to port status turns to the specified active status."
|
|
::= { sensorProbeEnergySensorEntry 32 }
|
|
|
|
sensorProbeEnergySirenCycleTime OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Siren toggle period in seconds for Cycle action."
|
|
::= { sensorProbeEnergySensorEntry 37 }
|
|
|
|
sensorProbeEnergySirenOnPort OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The sensor port that the siren will listen to. If this is set to 255, then the siren will not listen to any sensor ports"
|
|
::= { sensorProbeEnergySensorEntry 38 }
|
|
|
|
sensorProbeEnergySirenActiveStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
highWarning(3),
|
|
highCritical(4),
|
|
lowWarning(5),
|
|
lowCritical(6),
|
|
anyError(7)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor status that will activate the siren"
|
|
::= { sensorProbeEnergySensorEntry 39 }
|
|
|
|
sensorProbeEnergySirenAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cycle(2),
|
|
turn-on(3),
|
|
turn-off(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"What the siren will do when the listened to port status turns to the specified active status."
|
|
::= { sensorProbeEnergySensorEntry 40 }
|
|
|
|
sensorProbeEnergyAcknowledgement OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ack(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Acknowledged sensor error and stop notification"
|
|
::= { sensorProbeEnergySensorEntry 41 }
|
|
|
|
sensorProbeEnergySirenDelayAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Siren delay in seconds before start Alarm."
|
|
::= { sensorProbeEnergySensorEntry 42 }
|
|
|
|
sensorProbeEnergyReadingMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
active(0),
|
|
apparent(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Energy Meter Reading Mode."
|
|
::= { sensorProbeEnergySensorEntry 43 }
|
|
|
|
sensorProbeEnergyURL OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor URL link."
|
|
::= { sensorProbeEnergySensorEntry 44 }
|
|
|
|
sensorProbeEnergyOpenURL OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cur-window(0),
|
|
new-window(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Open URL in this browser or open in a new window."
|
|
::= { sensorProbeEnergySensorEntry 45 }
|
|
|
|
sensorProbeEnergyDatacollectType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
average(1),
|
|
highest(2),
|
|
lowest(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Type of datacollect to collect."
|
|
::= { sensorProbeEnergySensorEntry 46 }
|
|
|
|
sensorProbeEnergyContTimeHighCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in High Critical before accepting new Status."
|
|
::= { sensorProbeEnergySensorEntry 47 }
|
|
|
|
sensorProbeEnergyContTimeHighWarning OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in High Warning before accepting new Status."
|
|
::= { sensorProbeEnergySensorEntry 48 }
|
|
|
|
sensorProbeEnergyContTimeNormal OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Normal before accepting new Status."
|
|
::= { sensorProbeEnergySensorEntry 49 }
|
|
|
|
sensorProbeEnergyContTimeLowWarning OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Low Warning before accepting new Status."
|
|
::= { sensorProbeEnergySensorEntry 50 }
|
|
|
|
sensorProbeEnergyContTimeLowCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Low Critical before accepting new Status."
|
|
::= { sensorProbeEnergySensorEntry 51 }
|
|
|
|
sensorProbeEnergyContTimeSensorError OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Sensor Error before accepting new Status."
|
|
::= { sensorProbeEnergySensorEntry 52 }
|
|
|
|
sensorProbeEnergyCalendar OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable the calendar filtering working hours of sensor."
|
|
::= { sensorProbeEnergySensorEntry 53 }
|
|
|
|
sensorProbeRelayArraySensor OBJECT IDENTIFIER ::= { sensorProbeOtherSensor 29 }
|
|
|
|
sensorProbeRelayArrayPort1 OBJECT IDENTIFIER ::= { sensorProbeRelayArraySensor 1 }
|
|
sensorProbeRelayArrayPort1Number OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of port on the RelayArray."
|
|
::= { sensorProbeRelayArrayPort1 1 }
|
|
|
|
sensorProbeRelayArrayPort1Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorProbeRelayArrayPort1Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the data for every Switch Sensor in the SensorArray. Each row in the table contains data for a different Switch Sensor."
|
|
::= { sensorProbeRelayArrayPort1 2 }
|
|
|
|
sensorProbeRelayArrayPort1Entry OBJECT-TYPE
|
|
SYNTAX SensorProbeRelayArrayPort1Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorProbeRelayArrayPort1 Table"
|
|
INDEX { sensorProbeRelayArrayPort1Index }
|
|
::= { sensorProbeRelayArrayPort1Table 1 }
|
|
|
|
SensorProbeRelayArrayPort1Entry ::= SEQUENCE {
|
|
sensorProbeRelayArrayPort1Index
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort1Description
|
|
DisplayString,
|
|
sensorProbeRelayArrayPort1Status
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort1Online
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort1GoOnline
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort1NormalState
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort1RelayCycleTime
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort1RelayAction
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort1ManualRelayCycleTime
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort1ManualRelayAction
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort1RelayDescOn
|
|
DisplayString,
|
|
sensorProbeRelayArrayPort1RelayDescOff
|
|
DisplayString,
|
|
sensorProbeRelayArrayPort1URL
|
|
DisplayString,
|
|
sensorProbeRelayArrayPort1OpenURL
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort1ControlMode
|
|
INTEGER
|
|
}
|
|
|
|
sensorProbeRelayArrayPort1Index OBJECT-TYPE
|
|
SYNTAX INTEGER (0..7)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value for each sensor RelayArray port."
|
|
::= { sensorProbeRelayArrayPort1Entry 1 }
|
|
|
|
sensorProbeRelayArrayPort1Description OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor RelayArray"
|
|
::= { sensorProbeRelayArrayPort1Entry 2 }
|
|
|
|
sensorProbeRelayArrayPort1Status OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highCritical(4),
|
|
lowCritical(6),
|
|
sensorError(7),
|
|
relayOn(8),
|
|
relayOff(9)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor"
|
|
::= { sensorProbeRelayArrayPort1Entry 4 }
|
|
|
|
sensorProbeRelayArrayPort1Online OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
offline(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If this Sensor is currently online"
|
|
::= { sensorProbeRelayArrayPort1Entry 5 }
|
|
|
|
sensorProbeRelayArrayPort1GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To put online enter a 1, to take offline enter a 2"
|
|
::= { sensorProbeRelayArrayPort1Entry 6 }
|
|
|
|
sensorProbeRelayArrayPort1NormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
closed(0),
|
|
open(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The normal state of RelayArray"
|
|
::= { sensorProbeRelayArrayPort1Entry 7 }
|
|
|
|
sensorProbeRelayArrayPort1RelayCycleTime OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Relay toggle period in seconds for Cycle action."
|
|
::= { sensorProbeRelayArrayPort1Entry 18 }
|
|
|
|
sensorProbeRelayArrayPort1RelayAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cycle(2),
|
|
turn-on(3),
|
|
turn-off(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"What the relay will do when the listened to port status turns to the specified active status."
|
|
::= { sensorProbeRelayArrayPort1Entry 21 }
|
|
|
|
sensorProbeRelayArrayPort1ManualRelayCycleTime OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Relay toggle period in seconds for Manual Cycle action."
|
|
::= { sensorProbeRelayArrayPort1Entry 24 }
|
|
|
|
sensorProbeRelayArrayPort1ManualRelayAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
allow-sensor-control(1),
|
|
turn-on(3),
|
|
turn-off(4),
|
|
cycle-Off-On-Off(7),
|
|
cycle-On-Off-On(8)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Control the relay manualy"
|
|
::= { sensorProbeRelayArrayPort1Entry 25 }
|
|
|
|
sensorProbeRelayArrayPort1RelayDescOn OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of relay On"
|
|
::= { sensorProbeRelayArrayPort1Entry 26 }
|
|
|
|
sensorProbeRelayArrayPort1RelayDescOff OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of relay Off"
|
|
::= { sensorProbeRelayArrayPort1Entry 27 }
|
|
|
|
sensorProbeRelayArrayPort1URL OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sersor URL link."
|
|
::= { sensorProbeRelayArrayPort1Entry 28 }
|
|
|
|
sensorProbeRelayArrayPort1OpenURL OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cur-window(0),
|
|
new-window(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Open URL in this browser or open in a new window."
|
|
::= { sensorProbeRelayArrayPort1Entry 29 }
|
|
|
|
sensorProbeRelayArrayPort1ControlMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
manual-control(0),
|
|
notification-control(1),
|
|
time-control(2),
|
|
thermostat-control(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Relay Control Mode used for selecting the mode to control a relay."
|
|
::= { sensorProbeRelayArrayPort1Entry 30 }
|
|
|
|
sensorProbeRelayArrayPort2 OBJECT IDENTIFIER ::= { sensorProbeRelayArraySensor 2 }
|
|
sensorProbeRelayArrayPort2Number OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of port on the RelayArray."
|
|
::= { sensorProbeRelayArrayPort2 1 }
|
|
|
|
sensorProbeRelayArrayPort2Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorProbeRelayArrayPort2Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the data for every Switch Sensor in the SensorArray. Each row in the table contains data for a different Switch Sensor."
|
|
::= { sensorProbeRelayArrayPort2 2 }
|
|
|
|
sensorProbeRelayArrayPort2Entry OBJECT-TYPE
|
|
SYNTAX SensorProbeRelayArrayPort2Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorProbeRelayArrayPort2 Table"
|
|
INDEX { sensorProbeRelayArrayPort2Index }
|
|
::= { sensorProbeRelayArrayPort2Table 1 }
|
|
|
|
SensorProbeRelayArrayPort2Entry ::= SEQUENCE {
|
|
sensorProbeRelayArrayPort2Index
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort2Description
|
|
DisplayString,
|
|
sensorProbeRelayArrayPort2Status
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort2Online
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort2GoOnline
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort2NormalState
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort2RelayCycleTime
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort2RelayAction
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort2ManualRelayCycleTime
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort2ManualRelayAction
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort2RelayDescOn
|
|
DisplayString,
|
|
sensorProbeRelayArrayPort2RelayDescOff
|
|
DisplayString,
|
|
sensorProbeRelayArrayPort2URL
|
|
DisplayString,
|
|
sensorProbeRelayArrayPort2OpenURL
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort2ControlMode
|
|
INTEGER
|
|
}
|
|
|
|
sensorProbeRelayArrayPort2Index OBJECT-TYPE
|
|
SYNTAX INTEGER (0..7)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value for each sensor RelayArray port."
|
|
::= { sensorProbeRelayArrayPort2Entry 1 }
|
|
|
|
sensorProbeRelayArrayPort2Description OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor RelayArray"
|
|
::= { sensorProbeRelayArrayPort2Entry 2 }
|
|
|
|
sensorProbeRelayArrayPort2Status OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highCritical(4),
|
|
lowCritical(6),
|
|
sensorError(7),
|
|
relayOn(8),
|
|
relayOff(9)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor"
|
|
::= { sensorProbeRelayArrayPort2Entry 4 }
|
|
|
|
sensorProbeRelayArrayPort2Online OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
offline(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If this Sensor is currently online"
|
|
::= { sensorProbeRelayArrayPort2Entry 5 }
|
|
|
|
sensorProbeRelayArrayPort2GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To put online enter a 1, to take offline enter a 2"
|
|
::= { sensorProbeRelayArrayPort2Entry 6 }
|
|
|
|
sensorProbeRelayArrayPort2NormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
closed(0),
|
|
open(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The normal state of RleayArray"
|
|
::= { sensorProbeRelayArrayPort2Entry 7 }
|
|
|
|
sensorProbeRelayArrayPort2RelayCycleTime OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Relay toggle period in seconds for Cycle action."
|
|
::= { sensorProbeRelayArrayPort2Entry 18 }
|
|
|
|
sensorProbeRelayArrayPort2RelayAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cycle(2),
|
|
turn-on(3),
|
|
turn-off(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"What the relay will do when the listened to port status turns to the specified active status."
|
|
::= { sensorProbeRelayArrayPort2Entry 21 }
|
|
|
|
sensorProbeRelayArrayPort2ManualRelayCycleTime OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Relay toggle period in seconds for Manual Cycle action."
|
|
::= { sensorProbeRelayArrayPort2Entry 24 }
|
|
|
|
sensorProbeRelayArrayPort2ManualRelayAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
allow-sensor-control(1),
|
|
turn-on(3),
|
|
turn-off(4),
|
|
cycle-Off-On-Off(7),
|
|
cycle-On-Off-On(8)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Control the relay manualy"
|
|
::= { sensorProbeRelayArrayPort2Entry 25 }
|
|
|
|
sensorProbeRelayArrayPort2RelayDescOn OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of relay On"
|
|
::= { sensorProbeRelayArrayPort2Entry 26 }
|
|
|
|
sensorProbeRelayArrayPort2RelayDescOff OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of relay Off"
|
|
::= { sensorProbeRelayArrayPort2Entry 27 }
|
|
|
|
sensorProbeRelayArrayPort2URL OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor URL link"
|
|
::= { sensorProbeRelayArrayPort2Entry 28 }
|
|
|
|
sensorProbeRelayArrayPort2OpenURL OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cur-window(0),
|
|
new-window(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Open URL in this browser or open in a new window."
|
|
::= { sensorProbeRelayArrayPort2Entry 29 }
|
|
|
|
sensorProbeRelayArrayPort2ControlMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
manual-control(0),
|
|
notification-control(1),
|
|
time-control(2),
|
|
thermostat-control(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Relay Control Mode used for selecting the mode to control a relay."
|
|
::= { sensorProbeRelayArrayPort2Entry 30 }
|
|
|
|
sensorProbeRelayArrayPort3 OBJECT IDENTIFIER ::= { sensorProbeRelayArraySensor 3 }
|
|
sensorProbeRelayArrayPort3Number OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of port on the RelayArray."
|
|
::= { sensorProbeRelayArrayPort3 1 }
|
|
|
|
sensorProbeRelayArrayPort3Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorProbeRelayArrayPort3Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the data for every Switch Sensor in the SensorArray. Each row in the table contains data for a different Switch Sensor."
|
|
::= { sensorProbeRelayArrayPort3 2 }
|
|
|
|
sensorProbeRelayArrayPort3Entry OBJECT-TYPE
|
|
SYNTAX SensorProbeRelayArrayPort3Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorProbeRelayArrayPort3 Table"
|
|
INDEX { sensorProbeRelayArrayPort3Index }
|
|
::= { sensorProbeRelayArrayPort3Table 1 }
|
|
|
|
SensorProbeRelayArrayPort3Entry ::= SEQUENCE {
|
|
sensorProbeRelayArrayPort3Index
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort3Description
|
|
DisplayString,
|
|
sensorProbeRelayArrayPort3Status
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort3Online
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort3GoOnline
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort3NormalState
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort3RelayCycleTime
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort3RelayAction
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort3ManualRelayCycleTime
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort3ManualRelayAction
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort3RelayDescOn
|
|
DisplayString,
|
|
sensorProbeRelayArrayPort3RelayDescOff
|
|
DisplayString,
|
|
sensorProbeRelayArrayPort3URL
|
|
DisplayString,
|
|
sensorProbeRelayArrayPort3OpenURL
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort3ControlMode
|
|
INTEGER
|
|
}
|
|
|
|
sensorProbeRelayArrayPort3Index OBJECT-TYPE
|
|
SYNTAX INTEGER (0..7)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value for each sensor RelayArray port."
|
|
::= { sensorProbeRelayArrayPort3Entry 1 }
|
|
|
|
sensorProbeRelayArrayPort3Description OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor RelayArray"
|
|
::= { sensorProbeRelayArrayPort3Entry 2 }
|
|
|
|
sensorProbeRelayArrayPort3Status OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highCritical(4),
|
|
lowCritical(6),
|
|
sensorError(7),
|
|
relayOn(8),
|
|
relayOff(9)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor"
|
|
::= { sensorProbeRelayArrayPort3Entry 4 }
|
|
|
|
sensorProbeRelayArrayPort3Online OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
offline(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If this Sensor is currently online"
|
|
::= { sensorProbeRelayArrayPort3Entry 5 }
|
|
|
|
sensorProbeRelayArrayPort3GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To put online enter a 1, to take offline enter a 2"
|
|
::= { sensorProbeRelayArrayPort3Entry 6 }
|
|
|
|
sensorProbeRelayArrayPort3NormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
closed(0),
|
|
open(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The normal state of RleayArray"
|
|
::= { sensorProbeRelayArrayPort3Entry 7 }
|
|
|
|
sensorProbeRelayArrayPort3RelayCycleTime OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Relay toggle period in seconds for Cycle action."
|
|
::= { sensorProbeRelayArrayPort3Entry 18 }
|
|
|
|
sensorProbeRelayArrayPort3RelayAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cycle(2),
|
|
turn-on(3),
|
|
turn-off(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"What the relay will do when the listened to port status turns to the specified active status."
|
|
::= { sensorProbeRelayArrayPort3Entry 21 }
|
|
|
|
sensorProbeRelayArrayPort3ManualRelayCycleTime OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Relay toggle period in seconds for Manual Cycle action."
|
|
::= { sensorProbeRelayArrayPort3Entry 24 }
|
|
|
|
sensorProbeRelayArrayPort3ManualRelayAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
allow-sensor-control(1),
|
|
turn-on(3),
|
|
turn-off(4),
|
|
cycle-Off-On-Off(7),
|
|
cycle-On-Off-On(8)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Control the relay manualy"
|
|
::= { sensorProbeRelayArrayPort3Entry 25 }
|
|
|
|
sensorProbeRelayArrayPort3RelayDescOn OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of relay On"
|
|
::= { sensorProbeRelayArrayPort3Entry 26 }
|
|
|
|
sensorProbeRelayArrayPort3RelayDescOff OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of relay Off"
|
|
::= { sensorProbeRelayArrayPort3Entry 27 }
|
|
|
|
sensorProbeRelayArrayPort3URL OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor URL link."
|
|
::= { sensorProbeRelayArrayPort3Entry 28 }
|
|
|
|
sensorProbeRelayArrayPort3OpenURL OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cur-window(0),
|
|
new-window(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Open URL in this browser or open in a new window."
|
|
::= { sensorProbeRelayArrayPort3Entry 29 }
|
|
|
|
sensorProbeRelayArrayPort3ControlMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
manual-control(0),
|
|
notification-control(1),
|
|
time-control(2),
|
|
thermostat-control(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Relay Control Mode used for selecting the mode to control a relay."
|
|
::= { sensorProbeRelayArrayPort3Entry 30 }
|
|
|
|
sensorProbeRelayArrayPort4 OBJECT IDENTIFIER ::= { sensorProbeRelayArraySensor 4 }
|
|
sensorProbeRelayArrayPort4Number OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of port on the RelayArray."
|
|
::= { sensorProbeRelayArrayPort4 1 }
|
|
|
|
sensorProbeRelayArrayPort4Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorProbeRelayArrayPort4Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the data for every Switch Sensor in the SensorArray. Each row in the table contains data for a different Switch Sensor."
|
|
::= { sensorProbeRelayArrayPort4 2 }
|
|
|
|
sensorProbeRelayArrayPort4Entry OBJECT-TYPE
|
|
SYNTAX SensorProbeRelayArrayPort4Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorProbeRelayArrayPort4 Table"
|
|
INDEX { sensorProbeRelayArrayPort4Index }
|
|
::= { sensorProbeRelayArrayPort4Table 1 }
|
|
|
|
SensorProbeRelayArrayPort4Entry ::= SEQUENCE {
|
|
sensorProbeRelayArrayPort4Index
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort4Description
|
|
DisplayString,
|
|
sensorProbeRelayArrayPort4Status
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort4Online
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort4GoOnline
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort4NormalState
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort4RelayCycleTime
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort4RelayAction
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort4ManualRelayCycleTime
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort4ManualRelayAction
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort4RelayDescOn
|
|
DisplayString,
|
|
sensorProbeRelayArrayPort4RelayDescOff
|
|
DisplayString,
|
|
sensorProbeRelayArrayPort4URL
|
|
DisplayString,
|
|
sensorProbeRelayArrayPort4OpenURL
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort4ControlMode
|
|
INTEGER
|
|
}
|
|
|
|
sensorProbeRelayArrayPort4Index OBJECT-TYPE
|
|
SYNTAX INTEGER (0..7)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value for each sensor RelayArray port."
|
|
::= { sensorProbeRelayArrayPort4Entry 1 }
|
|
|
|
sensorProbeRelayArrayPort4Description OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor RelayArray"
|
|
::= { sensorProbeRelayArrayPort4Entry 2 }
|
|
|
|
sensorProbeRelayArrayPort4Status OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highCritical(4),
|
|
lowCritical(6),
|
|
sensorError(7),
|
|
relayOn(8),
|
|
relayOff(9)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor"
|
|
::= { sensorProbeRelayArrayPort4Entry 4 }
|
|
|
|
sensorProbeRelayArrayPort4Online OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
offline(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If this Sensor is currently online"
|
|
::= { sensorProbeRelayArrayPort4Entry 5 }
|
|
|
|
sensorProbeRelayArrayPort4GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To put online enter a 1, to take offline enter a 2"
|
|
::= { sensorProbeRelayArrayPort4Entry 6 }
|
|
|
|
sensorProbeRelayArrayPort4NormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
closed(0),
|
|
open(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The normal state of RleayArray"
|
|
::= { sensorProbeRelayArrayPort4Entry 7 }
|
|
|
|
sensorProbeRelayArrayPort4RelayCycleTime OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Relay toggle period in seconds for Cycle action."
|
|
::= { sensorProbeRelayArrayPort4Entry 18 }
|
|
|
|
sensorProbeRelayArrayPort4RelayAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cycle(2),
|
|
turn-on(3),
|
|
turn-off(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"What the relay will do when the listened to port status turns to the specified active status."
|
|
::= { sensorProbeRelayArrayPort4Entry 21 }
|
|
|
|
sensorProbeRelayArrayPort4ManualRelayCycleTime OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Relay toggle period in seconds for Manual Cycle action."
|
|
::= { sensorProbeRelayArrayPort4Entry 24 }
|
|
|
|
sensorProbeRelayArrayPort4ManualRelayAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
allow-sensor-control(1),
|
|
turn-on(3),
|
|
turn-off(4),
|
|
cycle-Off-On-Off(7),
|
|
cycle-On-Off-On(8)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Control the relay manualy"
|
|
::= { sensorProbeRelayArrayPort4Entry 25 }
|
|
|
|
sensorProbeRelayArrayPort4RelayDescOn OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of relay On"
|
|
::= { sensorProbeRelayArrayPort4Entry 26 }
|
|
|
|
sensorProbeRelayArrayPort4RelayDescOff OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of relay Off"
|
|
::= { sensorProbeRelayArrayPort4Entry 27 }
|
|
|
|
sensorProbeRelayArrayPort4URL OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor URL link."
|
|
::= { sensorProbeRelayArrayPort4Entry 28 }
|
|
|
|
sensorProbeRelayArrayPort4OpenURL OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cur-window(0),
|
|
new-window(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Open URL in this browser or open in a new window."
|
|
::= { sensorProbeRelayArrayPort4Entry 29 }
|
|
|
|
sensorProbeRelayArrayPort4ControlMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
manual-control(0),
|
|
notification-control(1),
|
|
time-control(2),
|
|
thermostat-control(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Relay Control Mode used for selecting the mode to control a relay."
|
|
::= { sensorProbeRelayArrayPort4Entry 30 }
|
|
|
|
sensorProbeRelayArrayPort5 OBJECT IDENTIFIER ::= { sensorProbeRelayArraySensor 5 }
|
|
sensorProbeRelayArrayPort5Number OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of port on the RelayArray."
|
|
::= { sensorProbeRelayArrayPort5 1 }
|
|
|
|
sensorProbeRelayArrayPort5Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorProbeRelayArrayPort5Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the data for every Switch Sensor in the SensorArray. Each row in the table contains data for a different Switch Sensor."
|
|
::= { sensorProbeRelayArrayPort5 2 }
|
|
|
|
sensorProbeRelayArrayPort5Entry OBJECT-TYPE
|
|
SYNTAX SensorProbeRelayArrayPort5Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorProbeRelayArrayPort5 Table"
|
|
INDEX { sensorProbeRelayArrayPort5Index }
|
|
::= { sensorProbeRelayArrayPort5Table 1 }
|
|
|
|
SensorProbeRelayArrayPort5Entry ::= SEQUENCE {
|
|
sensorProbeRelayArrayPort5Index
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort5Description
|
|
DisplayString,
|
|
sensorProbeRelayArrayPort5Status
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort5Online
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort5GoOnline
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort5NormalState
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort5RelayCycleTime
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort5RelayAction
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort5ManualRelayCycleTime
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort5ManualRelayAction
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort5RelayDescOn
|
|
DisplayString,
|
|
sensorProbeRelayArrayPort5RelayDescOff
|
|
DisplayString,
|
|
sensorProbeRelayArrayPort5URL
|
|
DisplayString,
|
|
sensorProbeRelayArrayPort5OpenURL
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort5ControlMode
|
|
INTEGER
|
|
}
|
|
|
|
sensorProbeRelayArrayPort5Index OBJECT-TYPE
|
|
SYNTAX INTEGER (0..7)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value for each sensor RelayArray port."
|
|
::= { sensorProbeRelayArrayPort5Entry 1 }
|
|
|
|
sensorProbeRelayArrayPort5Description OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor RelayArray"
|
|
::= { sensorProbeRelayArrayPort5Entry 2 }
|
|
|
|
sensorProbeRelayArrayPort5Status OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highCritical(4),
|
|
lowCritical(6),
|
|
sensorError(7),
|
|
relayOn(8),
|
|
relayOff(9)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor"
|
|
::= { sensorProbeRelayArrayPort5Entry 4 }
|
|
|
|
sensorProbeRelayArrayPort5Online OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
offline(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If this Sensor is currently online"
|
|
::= { sensorProbeRelayArrayPort5Entry 5 }
|
|
|
|
sensorProbeRelayArrayPort5GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To put online enter a 1, to take offline enter a 2"
|
|
::= { sensorProbeRelayArrayPort5Entry 6 }
|
|
|
|
sensorProbeRelayArrayPort5NormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
closed(0),
|
|
open(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The normal state of RleayArray"
|
|
::= { sensorProbeRelayArrayPort5Entry 7 }
|
|
|
|
sensorProbeRelayArrayPort5RelayCycleTime OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Relay toggle period in seconds for Cycle action."
|
|
::= { sensorProbeRelayArrayPort5Entry 18 }
|
|
|
|
sensorProbeRelayArrayPort5RelayAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cycle(2),
|
|
turn-on(3),
|
|
turn-off(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"What the relay will do when the listened to port status turns to the specified active status."
|
|
::= { sensorProbeRelayArrayPort5Entry 21 }
|
|
|
|
sensorProbeRelayArrayPort5ManualRelayCycleTime OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Relay toggle period in seconds for Manual Cycle action."
|
|
::= { sensorProbeRelayArrayPort5Entry 24 }
|
|
|
|
sensorProbeRelayArrayPort5ManualRelayAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
allow-sensor-control(1),
|
|
turn-on(3),
|
|
turn-off(4),
|
|
cycle-Off-On-Off(7),
|
|
cycle-On-Off-On(8)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Control the relay manualy"
|
|
::= { sensorProbeRelayArrayPort5Entry 25 }
|
|
|
|
sensorProbeRelayArrayPort5RelayDescOn OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of relay On"
|
|
::= { sensorProbeRelayArrayPort5Entry 26 }
|
|
|
|
sensorProbeRelayArrayPort5RelayDescOff OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of relay Off"
|
|
::= { sensorProbeRelayArrayPort5Entry 27 }
|
|
|
|
sensorProbeRelayArrayPort5URL OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor URL link."
|
|
::= { sensorProbeRelayArrayPort5Entry 28 }
|
|
|
|
sensorProbeRelayArrayPort5OpenURL OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cur-window(0),
|
|
new-window(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Open URL in this browser or open in a new window."
|
|
::= { sensorProbeRelayArrayPort5Entry 29 }
|
|
|
|
sensorProbeRelayArrayPort5ControlMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
manual-control(0),
|
|
notification-control(1),
|
|
time-control(2),
|
|
thermostat-control(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Relay Control Mode used for selecting the mode to control a relay."
|
|
::= { sensorProbeRelayArrayPort5Entry 30 }
|
|
|
|
sensorProbeRelayArrayPort6 OBJECT IDENTIFIER ::= { sensorProbeRelayArraySensor 6 }
|
|
sensorProbeRelayArrayPort6Number OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of port on the RelayArray."
|
|
::= { sensorProbeRelayArrayPort6 1 }
|
|
|
|
sensorProbeRelayArrayPort6Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorProbeRelayArrayPort6Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the data for every Switch Sensor in the SensorArray. Each row in the table contains data for a different Switch Sensor."
|
|
::= { sensorProbeRelayArrayPort6 2 }
|
|
|
|
sensorProbeRelayArrayPort6Entry OBJECT-TYPE
|
|
SYNTAX SensorProbeRelayArrayPort6Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorProbeRelayArrayPort6 Table"
|
|
INDEX { sensorProbeRelayArrayPort6Index }
|
|
::= { sensorProbeRelayArrayPort6Table 1 }
|
|
|
|
SensorProbeRelayArrayPort6Entry ::= SEQUENCE {
|
|
sensorProbeRelayArrayPort6Index
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort6Description
|
|
DisplayString,
|
|
sensorProbeRelayArrayPort6Status
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort6Online
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort6GoOnline
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort6NormalState
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort6RelayCycleTime
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort6RelayAction
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort6ManualRelayCycleTime
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort6ManualRelayAction
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort6RelayDescOn
|
|
DisplayString,
|
|
sensorProbeRelayArrayPort6RelayDescOff
|
|
DisplayString,
|
|
sensorProbeRelayArrayPort6URL
|
|
DisplayString,
|
|
sensorProbeRelayArrayPort6OpenURL
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort6ControlMode
|
|
INTEGER
|
|
}
|
|
|
|
sensorProbeRelayArrayPort6Index OBJECT-TYPE
|
|
SYNTAX INTEGER (0..7)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value for each sensor RelayArray port."
|
|
::= { sensorProbeRelayArrayPort6Entry 1 }
|
|
|
|
sensorProbeRelayArrayPort6Description OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor RelayArray"
|
|
::= { sensorProbeRelayArrayPort6Entry 2 }
|
|
|
|
sensorProbeRelayArrayPort6Status OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highCritical(4),
|
|
lowCritical(6),
|
|
sensorError(7),
|
|
relayOn(8),
|
|
relayOff(9)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor"
|
|
::= { sensorProbeRelayArrayPort6Entry 4 }
|
|
|
|
sensorProbeRelayArrayPort6Online OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
offline(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If this Sensor is currently online"
|
|
::= { sensorProbeRelayArrayPort6Entry 5 }
|
|
|
|
sensorProbeRelayArrayPort6GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To put online enter a 1, to take offline enter a 2"
|
|
::= { sensorProbeRelayArrayPort6Entry 6 }
|
|
|
|
sensorProbeRelayArrayPort6NormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
closed(0),
|
|
open(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The normal state of RleayArray"
|
|
::= { sensorProbeRelayArrayPort6Entry 7 }
|
|
|
|
sensorProbeRelayArrayPort6RelayCycleTime OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Relay toggle period in seconds for Cycle action."
|
|
::= { sensorProbeRelayArrayPort6Entry 18 }
|
|
|
|
sensorProbeRelayArrayPort6RelayAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cycle(2),
|
|
turn-on(3),
|
|
turn-off(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"What the relay will do when the listened to port status turns to the specified active status."
|
|
::= { sensorProbeRelayArrayPort6Entry 21 }
|
|
|
|
sensorProbeRelayArrayPort6ManualRelayCycleTime OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Relay toggle period in seconds for Manual Cycle action."
|
|
::= { sensorProbeRelayArrayPort6Entry 24 }
|
|
|
|
sensorProbeRelayArrayPort6ManualRelayAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
allow-sensor-control(1),
|
|
turn-on(3),
|
|
turn-off(4),
|
|
cycle-Off-On-Off(7),
|
|
cycle-On-Off-On(8)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Control the relay manualy"
|
|
::= { sensorProbeRelayArrayPort6Entry 25 }
|
|
|
|
sensorProbeRelayArrayPort6RelayDescOn OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of relay On"
|
|
::= { sensorProbeRelayArrayPort6Entry 26 }
|
|
|
|
sensorProbeRelayArrayPort6RelayDescOff OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of relay Off"
|
|
::= { sensorProbeRelayArrayPort6Entry 27 }
|
|
|
|
sensorProbeRelayArrayPort6URL OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor URL link."
|
|
::= { sensorProbeRelayArrayPort6Entry 28 }
|
|
|
|
sensorProbeRelayArrayPort6OpenURL OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cur-window(0),
|
|
new-window(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Open URL in this browser or open in a new window."
|
|
::= { sensorProbeRelayArrayPort6Entry 29 }
|
|
|
|
sensorProbeRelayArrayPort6ControlMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
manual-control(0),
|
|
notification-control(1),
|
|
time-control(2),
|
|
thermostat-control(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Relay Control Mode used for selecting the mode to control a relay."
|
|
::= { sensorProbeRelayArrayPort6Entry 30 }
|
|
|
|
sensorProbeRelayArrayPort7 OBJECT IDENTIFIER ::= { sensorProbeRelayArraySensor 7 }
|
|
sensorProbeRelayArrayPort7Number OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of port on the RelayArray."
|
|
::= { sensorProbeRelayArrayPort7 1 }
|
|
|
|
sensorProbeRelayArrayPort7Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorProbeRelayArrayPort7Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the data for every Switch Sensor in the SensorArray. Each row in the table contains data for a different Switch Sensor."
|
|
::= { sensorProbeRelayArrayPort7 2 }
|
|
|
|
sensorProbeRelayArrayPort7Entry OBJECT-TYPE
|
|
SYNTAX SensorProbeRelayArrayPort7Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorProbeRelayArrayPort7 Table"
|
|
INDEX { sensorProbeRelayArrayPort7Index }
|
|
::= { sensorProbeRelayArrayPort7Table 1 }
|
|
|
|
SensorProbeRelayArrayPort7Entry ::= SEQUENCE {
|
|
sensorProbeRelayArrayPort7Index
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort7Description
|
|
DisplayString,
|
|
sensorProbeRelayArrayPort7Status
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort7Online
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort7GoOnline
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort7NormalState
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort7RelayCycleTime
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort7RelayAction
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort7ManualRelayCycleTime
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort7ManualRelayAction
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort7RelayDescOn
|
|
DisplayString,
|
|
sensorProbeRelayArrayPort7RelayDescOff
|
|
DisplayString,
|
|
sensorProbeRelayArrayPort7URL
|
|
DisplayString,
|
|
sensorProbeRelayArrayPort7OpenURL
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort7ControlMode
|
|
INTEGER
|
|
}
|
|
|
|
sensorProbeRelayArrayPort7Index OBJECT-TYPE
|
|
SYNTAX INTEGER (0..7)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value for each sensor RelayArray port."
|
|
::= { sensorProbeRelayArrayPort7Entry 1 }
|
|
|
|
sensorProbeRelayArrayPort7Description OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor RelayArray"
|
|
::= { sensorProbeRelayArrayPort7Entry 2 }
|
|
|
|
sensorProbeRelayArrayPort7Status OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highCritical(4),
|
|
lowCritical(6),
|
|
sensorError(7),
|
|
relayOn(8),
|
|
relayOff(9)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor"
|
|
::= { sensorProbeRelayArrayPort7Entry 4 }
|
|
|
|
sensorProbeRelayArrayPort7Online OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
offline(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If this Sensor is currently online"
|
|
::= { sensorProbeRelayArrayPort7Entry 5 }
|
|
|
|
sensorProbeRelayArrayPort7GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To put online enter a 1, to take offline enter a 2"
|
|
::= { sensorProbeRelayArrayPort7Entry 6 }
|
|
|
|
sensorProbeRelayArrayPort7NormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
closed(0),
|
|
open(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The normal state of RleayArray"
|
|
::= { sensorProbeRelayArrayPort7Entry 7 }
|
|
|
|
sensorProbeRelayArrayPort7RelayCycleTime OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Relay toggle period in seconds for Cycle action."
|
|
::= { sensorProbeRelayArrayPort7Entry 18 }
|
|
|
|
sensorProbeRelayArrayPort7RelayAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cycle(2),
|
|
turn-on(3),
|
|
turn-off(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"What the relay will do when the listened to port status turns to the specified active status."
|
|
::= { sensorProbeRelayArrayPort7Entry 21 }
|
|
|
|
sensorProbeRelayArrayPort7ManualRelayCycleTime OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Relay toggle period in seconds for Manual Cycle action."
|
|
::= { sensorProbeRelayArrayPort7Entry 24 }
|
|
|
|
sensorProbeRelayArrayPort7ManualRelayAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
allow-sensor-control(1),
|
|
turn-on(3),
|
|
turn-off(4),
|
|
cycle-Off-On-Off(7),
|
|
cycle-On-Off-On(8)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Control the relay manualy"
|
|
::= { sensorProbeRelayArrayPort7Entry 25 }
|
|
|
|
sensorProbeRelayArrayPort7RelayDescOn OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of relay On"
|
|
::= { sensorProbeRelayArrayPort7Entry 26 }
|
|
|
|
sensorProbeRelayArrayPort7RelayDescOff OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of relay Off"
|
|
::= { sensorProbeRelayArrayPort7Entry 27 }
|
|
|
|
sensorProbeRelayArrayPort7URL OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor URL link."
|
|
::= { sensorProbeRelayArrayPort7Entry 28 }
|
|
|
|
sensorProbeRelayArrayPort7OpenURL OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cur-window(0),
|
|
new-window(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Open URL in this browser or open in a new window."
|
|
::= { sensorProbeRelayArrayPort7Entry 29 }
|
|
|
|
sensorProbeRelayArrayPort7ControlMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
manual-control(0),
|
|
notification-control(1),
|
|
time-control(2),
|
|
thermostat-control(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Relay Control Mode used for selecting the mode to control a relay."
|
|
::= { sensorProbeRelayArrayPort7Entry 30 }
|
|
|
|
sensorProbeRelayArrayPort8 OBJECT IDENTIFIER ::= { sensorProbeRelayArraySensor 8 }
|
|
sensorProbeRelayArrayPort8Number OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of port on the RelayArray."
|
|
::= { sensorProbeRelayArrayPort8 1 }
|
|
|
|
sensorProbeRelayArrayPort8Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorProbeRelayArrayPort8Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the data for every Switch Sensor in the SensorArray. Each row in the table contains data for a different Switch Sensor."
|
|
::= { sensorProbeRelayArrayPort8 2 }
|
|
|
|
sensorProbeRelayArrayPort8Entry OBJECT-TYPE
|
|
SYNTAX SensorProbeRelayArrayPort8Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorProbeRelayArrayPort8 Table"
|
|
INDEX { sensorProbeRelayArrayPort8Index }
|
|
::= { sensorProbeRelayArrayPort8Table 1 }
|
|
|
|
SensorProbeRelayArrayPort8Entry ::= SEQUENCE {
|
|
sensorProbeRelayArrayPort8Index
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort8Description
|
|
DisplayString,
|
|
sensorProbeRelayArrayPort8Status
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort8Online
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort8GoOnline
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort8NormalState
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort8RelayCycleTime
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort8RelayAction
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort8ManualRelayCycleTime
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort8ManualRelayAction
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort8RelayDescOn
|
|
DisplayString,
|
|
sensorProbeRelayArrayPort8RelayDescOff
|
|
DisplayString,
|
|
sensorProbeRelayArrayPort8URL
|
|
DisplayString,
|
|
sensorProbeRelayArrayPort8OpenURL
|
|
INTEGER,
|
|
sensorProbeRelayArrayPort8ControlMode
|
|
INTEGER
|
|
}
|
|
|
|
sensorProbeRelayArrayPort8Index OBJECT-TYPE
|
|
SYNTAX INTEGER (0..7)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value for each sensor RelayArray port."
|
|
::= { sensorProbeRelayArrayPort8Entry 1 }
|
|
|
|
sensorProbeRelayArrayPort8Description OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor RelayArray"
|
|
::= { sensorProbeRelayArrayPort8Entry 2 }
|
|
|
|
sensorProbeRelayArrayPort8Status OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highCritical(4),
|
|
lowCritical(6),
|
|
sensorError(7),
|
|
relayOn(8),
|
|
relayOff(9)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor"
|
|
::= { sensorProbeRelayArrayPort8Entry 4 }
|
|
|
|
sensorProbeRelayArrayPort8Online OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
offline(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If this Sensor is currently online"
|
|
::= { sensorProbeRelayArrayPort8Entry 5 }
|
|
|
|
sensorProbeRelayArrayPort8GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To put online enter a 1, to take offline enter a 2"
|
|
::= { sensorProbeRelayArrayPort8Entry 6 }
|
|
|
|
sensorProbeRelayArrayPort8NormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
closed(0),
|
|
open(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The normal state of RleayArray"
|
|
::= { sensorProbeRelayArrayPort8Entry 7 }
|
|
|
|
sensorProbeRelayArrayPort8RelayCycleTime OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Relay toggle period in seconds for Cycle action."
|
|
::= { sensorProbeRelayArrayPort8Entry 18 }
|
|
|
|
sensorProbeRelayArrayPort8RelayAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cycle(2),
|
|
turn-on(3),
|
|
turn-off(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"What the relay will do when the listened to port status turns to the specified active status."
|
|
::= { sensorProbeRelayArrayPort8Entry 21 }
|
|
|
|
sensorProbeRelayArrayPort8ManualRelayCycleTime OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Relay toggle period in seconds for Manual Cycle action."
|
|
::= { sensorProbeRelayArrayPort8Entry 24 }
|
|
|
|
sensorProbeRelayArrayPort8ManualRelayAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
allow-sensor-control(1),
|
|
turn-on(3),
|
|
turn-off(4),
|
|
cycle-Off-On-Off(7),
|
|
cycle-On-Off-On(8)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Control the relay manualy"
|
|
::= { sensorProbeRelayArrayPort8Entry 25 }
|
|
|
|
sensorProbeRelayArrayPort8RelayDescOn OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of relay On"
|
|
::= { sensorProbeRelayArrayPort8Entry 26 }
|
|
|
|
sensorProbeRelayArrayPort8RelayDescOff OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of relay Off"
|
|
::= { sensorProbeRelayArrayPort8Entry 27 }
|
|
|
|
sensorProbeRelayArrayPort8URL OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor URL link."
|
|
::= { sensorProbeRelayArrayPort8Entry 28 }
|
|
|
|
sensorProbeRelayArrayPort8OpenURL OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cur-window(0),
|
|
new-window(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Open URL in this browser or open in a new window."
|
|
::= { sensorProbeRelayArrayPort8Entry 29 }
|
|
|
|
sensorProbeRelayArrayPort8ControlMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
manual-control(0),
|
|
notification-control(1),
|
|
time-control(2),
|
|
thermostat-control(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Relay Control Mode used for selecting the mode to control a relay."
|
|
::= { sensorProbeRelayArrayPort8Entry 30 }
|
|
|
|
sensorProbeVirtualAnalogSensor OBJECT IDENTIFIER ::= { sensorProbeOtherSensor 30 }
|
|
|
|
sensorProbeVirtualAnalogSensorNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of VirtualAnalog Sensor port."
|
|
::= { sensorProbeVirtualAnalogSensor 1 }
|
|
|
|
sensorProbeVirtualAnalogSensorTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorProbeVirtualAnalogSensorEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the data for every VirtualAnalog Sensor in the SensorArray. Each row in the table contains data for a different VirtualAnalog Sensor."
|
|
::= { sensorProbeVirtualAnalogSensor 2 }
|
|
|
|
sensorProbeVirtualAnalogSensorEntry OBJECT-TYPE
|
|
SYNTAX SensorProbeVirtualAnalogSensorEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorProbeVirtualAnalogSensorEntry Table"
|
|
INDEX { sensorProbeVirtualAnalogSensorIndex }
|
|
::= { sensorProbeVirtualAnalogSensorTable 1 }
|
|
|
|
SensorProbeVirtualAnalogSensorEntry ::= SEQUENCE {
|
|
sensorProbeVirtualAnalogSensorIndex
|
|
INTEGER,
|
|
sensorProbeVirtualAnalogDescription
|
|
DisplayString,
|
|
sensorProbeVirtualAnalogStatus
|
|
INTEGER,
|
|
sensorProbeVirtualAnalogOnline
|
|
INTEGER,
|
|
sensorProbeVirtualAnalogGoOnline
|
|
INTEGER,
|
|
sensorProbeVirtualAnalogHighWarning
|
|
INTEGER,
|
|
sensorProbeVirtualAnalogHighCritical
|
|
INTEGER,
|
|
sensorProbeVirtualAnalogLowWarning
|
|
INTEGER,
|
|
sensorProbeVirtualAnalogLowCritical
|
|
INTEGER,
|
|
sensorProbeVirtualAnalogRearm
|
|
INTEGER,
|
|
sensorProbeVirtualAnalogRaw
|
|
INTEGER,
|
|
sensorProbeVirtualAnalogEmailTrapLimit
|
|
INTEGER,
|
|
sensorProbeVirtualAnalogDelayError
|
|
INTEGER,
|
|
sensorProbeVirtualAnalogDelayNormal
|
|
INTEGER,
|
|
sensorProbeVirtualAnalogUnit
|
|
DisplayString,
|
|
sensorProbeVirtualAnalogAcknowledgement
|
|
INTEGER,
|
|
sensorProbeVirtualAnalogURL
|
|
DisplayString,
|
|
sensorProbeVirtualAnalogOpenURL
|
|
INTEGER,
|
|
sensorProbeVirtualAnalogContTimeHighCritical
|
|
INTEGER,
|
|
sensorProbeVirtualAnalogContTimeHighWarning
|
|
INTEGER,
|
|
sensorProbeVirtualAnalogContTimeNormal
|
|
INTEGER,
|
|
sensorProbeVirtualAnalogContTimeLowWarning
|
|
INTEGER,
|
|
sensorProbeVirtualAnalogContTimeLowCritical
|
|
INTEGER,
|
|
sensorProbeVirtualAnalogContTimeSensorError
|
|
INTEGER,
|
|
sensorProbeVirtualAnalogCalendar
|
|
INTEGER,
|
|
sensorProbeVirtualAnalogValueFactor
|
|
INTEGER
|
|
}
|
|
|
|
sensorProbeVirtualAnalogSensorIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..67)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value for each VirtualAnalog sensor port."
|
|
::= { sensorProbeVirtualAnalogSensorEntry 1 }
|
|
|
|
sensorProbeVirtualAnalogDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor"
|
|
::= { sensorProbeVirtualAnalogSensorEntry 2 }
|
|
|
|
sensorProbeVirtualAnalogStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highWarning(3),
|
|
highCritical(4),
|
|
lowWarning(5),
|
|
lowCritical(6),
|
|
sensorError(7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor"
|
|
::= { sensorProbeVirtualAnalogSensorEntry 4 }
|
|
|
|
sensorProbeVirtualAnalogOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
offline(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If this Sensor is currently online"
|
|
::= { sensorProbeVirtualAnalogSensorEntry 5 }
|
|
|
|
sensorProbeVirtualAnalogGoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To put online enter a 1, to take offline enter a 2"
|
|
::= { sensorProbeVirtualAnalogSensorEntry 6 }
|
|
|
|
sensorProbeVirtualAnalogHighWarning OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How high the relative VirtualAnalog this sensor measures before it sends a warning"
|
|
::= { sensorProbeVirtualAnalogSensorEntry 7 }
|
|
|
|
sensorProbeVirtualAnalogHighCritical OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How high the relative VirtualAnalog this sensor measures before it becomes critical"
|
|
::= { sensorProbeVirtualAnalogSensorEntry 8 }
|
|
|
|
sensorProbeVirtualAnalogLowWarning OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How low the relative VirtualAnalog this sensor measures before it sends a warning"
|
|
::= { sensorProbeVirtualAnalogSensorEntry 9 }
|
|
|
|
sensorProbeVirtualAnalogLowCritical OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How low the relative VirtualAnalog this sensor measures before it becomes critical"
|
|
::= { sensorProbeVirtualAnalogSensorEntry 10 }
|
|
|
|
sensorProbeVirtualAnalogRearm OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The percent relative VirtualAnalog to rearm the status. For example if status goes from normal to warning, the VirtualAnalog must go down spAnalogueRearm below warning before the status goes to normal"
|
|
::= { sensorProbeVirtualAnalogSensorEntry 11 }
|
|
|
|
sensorProbeVirtualAnalogRaw OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unformatted, raw, A/D value in this sensor. Contains more resolution than the formated percentage. This number can go from 0 to 1023 depending on the input voltage"
|
|
::= { sensorProbeVirtualAnalogSensorEntry 13 }
|
|
|
|
sensorProbeVirtualAnalogEmailTrapLimit OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable email/trap limit feature"
|
|
::= { sensorProbeVirtualAnalogSensorEntry 17 }
|
|
|
|
sensorProbeVirtualAnalogDelayError OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time in seconds after the sensor has been in error status before report as an error"
|
|
::= { sensorProbeVirtualAnalogSensorEntry 21 }
|
|
|
|
sensorProbeVirtualAnalogDelayNormal OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time in seconds after the sensor change from error to normal before report as normal"
|
|
::= { sensorProbeVirtualAnalogSensorEntry 22 }
|
|
|
|
sensorProbeVirtualAnalogUnit OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Display unit in VirtualAnalog."
|
|
::= { sensorProbeVirtualAnalogSensorEntry 27 }
|
|
|
|
sensorProbeVirtualAnalogAcknowledgement OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ack(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Acknowledged sensor error and stop notification"
|
|
::= { sensorProbeVirtualAnalogSensorEntry 41 }
|
|
|
|
sensorProbeVirtualAnalogURL OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor URL link."
|
|
::= { sensorProbeVirtualAnalogSensorEntry 43 }
|
|
|
|
sensorProbeVirtualAnalogOpenURL OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cur-window(0),
|
|
new-window(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Open URL in this browser or open in a new window."
|
|
::= { sensorProbeVirtualAnalogSensorEntry 44 }
|
|
|
|
sensorProbeVirtualAnalogContTimeHighCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in High Critical before accepting new Status."
|
|
::= { sensorProbeVirtualAnalogSensorEntry 45 }
|
|
|
|
sensorProbeVirtualAnalogContTimeHighWarning OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in High Warning before accepting new Status."
|
|
::= { sensorProbeVirtualAnalogSensorEntry 46 }
|
|
|
|
sensorProbeVirtualAnalogContTimeNormal OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Normal before accepting new Status."
|
|
::= { sensorProbeVirtualAnalogSensorEntry 47 }
|
|
|
|
sensorProbeVirtualAnalogContTimeLowWarning OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Low Warning before accepting new Status."
|
|
::= { sensorProbeVirtualAnalogSensorEntry 48 }
|
|
|
|
sensorProbeVirtualAnalogContTimeLowCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Low Critical before accepting new Status."
|
|
::= { sensorProbeVirtualAnalogSensorEntry 49 }
|
|
|
|
sensorProbeVirtualAnalogContTimeSensorError OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Sensor Error before accepting new Status."
|
|
::= { sensorProbeVirtualAnalogSensorEntry 50 }
|
|
|
|
sensorProbeVirtualAnalogCalendar OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable the calendar filtering working hours of sensor."
|
|
::= { sensorProbeVirtualAnalogSensorEntry 51 }
|
|
|
|
sensorProbeVirtualAnalogValueFactor OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
x1(1),
|
|
x0-1(10),
|
|
x0-01(100),
|
|
x0-001(1000)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To change the ratio of value."
|
|
::= { sensorProbeVirtualAnalogSensorEntry 52 }
|
|
|
|
sensorProbeVirtualSwitchSensor OBJECT IDENTIFIER ::= { sensorProbeOtherSensor 31 }
|
|
|
|
sensorProbeVirtualSwitchSensorNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of VirtualSwitch Sensor port."
|
|
::= { sensorProbeVirtualSwitchSensor 1 }
|
|
|
|
sensorProbeVirtualSwitchSensorTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorProbeVirtualSwitchSensorEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the data for every VirtualSwitch Sensor in the SensorArray. Each row in the table contains data for a different VirtualSwitch Sensor."
|
|
::= { sensorProbeVirtualSwitchSensor 2 }
|
|
|
|
sensorProbeVirtualSwitchSensorEntry OBJECT-TYPE
|
|
SYNTAX SensorProbeVirtualSwitchSensorEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorProbeVirtualSwitchSensorEntry Table"
|
|
INDEX { sensorProbeVirtualSwitchSensorIndex }
|
|
::= { sensorProbeVirtualSwitchSensorTable 1 }
|
|
|
|
SensorProbeVirtualSwitchSensorEntry ::= SEQUENCE {
|
|
sensorProbeVirtualSwitchSensorIndex
|
|
INTEGER,
|
|
sensorProbeVirtualSwitchDescription
|
|
DisplayString,
|
|
sensorProbeVirtualSwitchStatus
|
|
INTEGER,
|
|
sensorProbeVirtualSwitchOnline
|
|
INTEGER,
|
|
sensorProbeVirtualSwitchGoOnline
|
|
INTEGER,
|
|
sensorProbeVirtualSwitchEmailTrapLimit
|
|
INTEGER,
|
|
sensorProbeVirtualSwitchContTimeHighCritical
|
|
INTEGER,
|
|
sensorProbeVirtualSwitchContTimeNormal
|
|
INTEGER,
|
|
sensorProbeVirtualSwitchDescriptionCritical
|
|
DisplayString,
|
|
sensorProbeVirtualSwitchDescriptionNormal
|
|
DisplayString,
|
|
sensorProbeVirtualSwitchAcknowledgement
|
|
INTEGER,
|
|
sensorProbeVirtualSwitchURL
|
|
DisplayString,
|
|
sensorProbeVirtualSwitchOpenURL
|
|
INTEGER,
|
|
sensorProbeVirtualSwitchCalendar
|
|
INTEGER,
|
|
sensorProbeVirtualSwitchNormalState
|
|
INTEGER
|
|
}
|
|
|
|
sensorProbeVirtualSwitchSensorIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..67)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value for each VirtualSwitch sensor port."
|
|
::= { sensorProbeVirtualSwitchSensorEntry 1 }
|
|
|
|
sensorProbeVirtualSwitchDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor"
|
|
::= { sensorProbeVirtualSwitchSensorEntry 2 }
|
|
|
|
sensorProbeVirtualSwitchStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highWarning(3),
|
|
highCritical(4),
|
|
lowWarning(5),
|
|
lowCritical(6),
|
|
sensorError(7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor"
|
|
::= { sensorProbeVirtualSwitchSensorEntry 4 }
|
|
|
|
sensorProbeVirtualSwitchOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
offline(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If this Sensor is currently online"
|
|
::= { sensorProbeVirtualSwitchSensorEntry 5 }
|
|
|
|
sensorProbeVirtualSwitchGoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To put online enter a 1, to take offline enter a 2"
|
|
::= { sensorProbeVirtualSwitchSensorEntry 6 }
|
|
|
|
sensorProbeVirtualSwitchEmailTrapLimit OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable email/trap limit feature"
|
|
::= { sensorProbeVirtualSwitchSensorEntry 17 }
|
|
|
|
sensorProbeVirtualSwitchContTimeHighCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in High Critical before accepting new Status."
|
|
::= { sensorProbeVirtualSwitchSensorEntry 21 }
|
|
|
|
sensorProbeVirtualSwitchContTimeNormal OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Normal before accepting new Status."
|
|
::= { sensorProbeVirtualSwitchSensorEntry 22 }
|
|
|
|
sensorProbeVirtualSwitchDescriptionCritical OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of status when the virsual switch is critical"
|
|
::= { sensorProbeVirtualSwitchSensorEntry 26 }
|
|
|
|
sensorProbeVirtualSwitchDescriptionNormal OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of status when the virsual switch is normal"
|
|
::= { sensorProbeVirtualSwitchSensorEntry 27 }
|
|
|
|
sensorProbeVirtualSwitchAcknowledgement OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ack(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Acknowledged sensor error and stop notification"
|
|
::= { sensorProbeVirtualSwitchSensorEntry 41 }
|
|
|
|
sensorProbeVirtualSwitchURL OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor URL link."
|
|
::= { sensorProbeVirtualSwitchSensorEntry 43 }
|
|
|
|
sensorProbeVirtualSwitchOpenURL OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cur-window(0),
|
|
new-window(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Open URL in this browser or open in a new window."
|
|
::= { sensorProbeVirtualSwitchSensorEntry 44 }
|
|
|
|
sensorProbeVirtualSwitchCalendar OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable the calendar filtering working hours of sensor."
|
|
::= { sensorProbeVirtualSwitchSensorEntry 45 }
|
|
|
|
sensorProbeVirtualSwitchNormalState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The normal state of a return of the virsual switch. If a return of the virsual switch is equal this normal state value, it is normal. Otherwise, it is critical."
|
|
::= { sensorProbeVirtualSwitchSensorEntry 46 }
|
|
|
|
sensorProbeWattHoursSensor OBJECT IDENTIFIER ::= { sensorProbeOtherSensor 32 }
|
|
|
|
sensorProbeWattHoursSensorNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of WattHours Sensor port."
|
|
::= { sensorProbeWattHoursSensor 1 }
|
|
|
|
sensorProbeWattHoursSensorTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorProbeWattHoursSensorEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the data for every WattHours Sensor in the SensorArray. Each row in the table contains data for a different WattHours Sensor."
|
|
::= { sensorProbeWattHoursSensor 2 }
|
|
|
|
sensorProbeWattHoursSensorEntry OBJECT-TYPE
|
|
SYNTAX SensorProbeWattHoursSensorEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorProbeWattHoursSensorEntry Table"
|
|
INDEX { sensorProbeWattHoursSensorIndex }
|
|
::= { sensorProbeWattHoursSensorTable 1 }
|
|
|
|
SensorProbeWattHoursSensorEntry ::= SEQUENCE {
|
|
sensorProbeWattHoursSensorIndex
|
|
INTEGER,
|
|
sensorProbeWattHoursDescription
|
|
DisplayString,
|
|
sensorProbeWattHoursPercent
|
|
INTEGER,
|
|
sensorProbeWattHoursReset
|
|
INTEGER
|
|
}
|
|
|
|
sensorProbeWattHoursSensorIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..7)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value for each WattHours sensor port."
|
|
::= { sensorProbeWattHoursSensorEntry 1 }
|
|
|
|
sensorProbeWattHoursDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor"
|
|
::= { sensorProbeWattHoursSensorEntry 2 }
|
|
|
|
sensorProbeWattHoursPercent OBJECT-TYPE
|
|
SYNTAX INTEGER (-32768..32767)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The relative WattHours percentage measured by this sensor"
|
|
::= { sensorProbeWattHoursSensorEntry 3 }
|
|
|
|
sensorProbeWattHoursReset OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The relative WattHours percentage measured by this sensor"
|
|
::= { sensorProbeWattHoursSensorEntry 43 }
|
|
|
|
sensorProbeTemperatureArraySensor OBJECT IDENTIFIER ::= { sensorProbeOtherSensor 33 }
|
|
|
|
sensorProbeTemperatureArrayPort1 OBJECT IDENTIFIER ::= { sensorProbeTemperatureArraySensor 1 }
|
|
sensorProbeTemperatureArrayPort1Number OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of port on the TemperatureArray."
|
|
::= { sensorProbeTemperatureArrayPort1 1 }
|
|
|
|
sensorProbeTemperatureArrayPort1Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorProbeTemperatureArrayPort1Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the data for every Switch Sensor in the SensorArray. Each row in the table contains data for a different Switch Sensor."
|
|
::= { sensorProbeTemperatureArrayPort1 2 }
|
|
|
|
sensorProbeTemperatureArrayPort1Entry OBJECT-TYPE
|
|
SYNTAX SensorProbeTemperatureArrayPort1Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorProbeTemperatureArrayPort1 Table"
|
|
INDEX { sensorProbeTemperatureArrayPort1Index }
|
|
::= { sensorProbeTemperatureArrayPort1Table 1 }
|
|
|
|
SensorProbeTemperatureArrayPort1Entry ::= SEQUENCE {
|
|
sensorProbeTemperatureArrayPort1Index
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort1Description
|
|
DisplayString,
|
|
sensorProbeTemperatureArrayPort1Value
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort1Status
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort1Online
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort1GoOnline
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort1HighWarning
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort1HighCritical
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort1LowWarning
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort1LowCritical
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort1Rearm
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort1DegreeType
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort1DegreeRaw
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort1Offset
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort1URL
|
|
DisplayString,
|
|
sensorProbeTemperatureArrayPort1OpenURL
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort1DatacollectType
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort1ContTimeHighCritical
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort1ContTimeHighWarning
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort1ContTimeNormal
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort1ContTimeLowWarning
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort1ContTimeLowCritical
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort1ContTimeSensorError
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort1Calendar
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort1Index
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort1Description
|
|
DisplayString,
|
|
sensorProbeThermostatTemperatureArrayPort1Value
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort1Online
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort1GoOnline
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort1Mode
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort1RelayControlPort
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort1NormalAction1
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort1HighLimit1
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort1HighLimitAction1
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort1LowLimit1
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort1LowLimitAction1
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort1NormalAction2
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort1HighLimit2
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort1HighLimitAction2
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort1LowLimit2
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort1LowLimitAction2
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort1EnableTime
|
|
DisplayString
|
|
}
|
|
|
|
sensorProbeTemperatureArrayPort1Index OBJECT-TYPE
|
|
SYNTAX INTEGER (0..7)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value for each sensor TemperatureArray port."
|
|
::= { sensorProbeTemperatureArrayPort1Entry 1 }
|
|
|
|
sensorProbeTemperatureArrayPort1Description OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor TemperatureArray"
|
|
::= { sensorProbeTemperatureArrayPort1Entry 2 }
|
|
|
|
sensorProbeTemperatureArrayPort1Value OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value in this sensor"
|
|
::= { sensorProbeTemperatureArrayPort1Entry 3 }
|
|
|
|
sensorProbeTemperatureArrayPort1Status OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highWarning(3),
|
|
highCritical(4),
|
|
lowWarning(5),
|
|
lowCritical(6),
|
|
sensorError(7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor"
|
|
::= { sensorProbeTemperatureArrayPort1Entry 4 }
|
|
|
|
sensorProbeTemperatureArrayPort1Online OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
offline(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If this Sensor is currently online"
|
|
::= { sensorProbeTemperatureArrayPort1Entry 5 }
|
|
|
|
sensorProbeTemperatureArrayPort1GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To put online enter a 1, to take offline enter a 2"
|
|
::= { sensorProbeTemperatureArrayPort1Entry 6 }
|
|
|
|
sensorProbeTemperatureArrayPort1HighWarning OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How hot this sensor gets before it sends a warning"
|
|
::= { sensorProbeTemperatureArrayPort1Entry 7 }
|
|
|
|
sensorProbeTemperatureArrayPort1HighCritical OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How hot this sensor gets before it sends a critical event"
|
|
::= { sensorProbeTemperatureArrayPort1Entry 8 }
|
|
|
|
sensorProbeTemperatureArrayPort1LowWarning OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How cold this sensor gets before it sends a warning"
|
|
::= { sensorProbeTemperatureArrayPort1Entry 9 }
|
|
|
|
sensorProbeTemperatureArrayPort1LowCritical OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How cold this sensor gets before it sends a critical event"
|
|
::= { sensorProbeTemperatureArrayPort1Entry 10 }
|
|
|
|
sensorProbeTemperatureArrayPort1Rearm OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of degrees to rearm the status. For example if status goes from normal to warning, the temp must go down spTempRearm degrees below warning before the status goes to normal"
|
|
::= { sensorProbeTemperatureArrayPort1Entry 11 }
|
|
|
|
sensorProbeTemperatureArrayPort1DegreeType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
fahr(0),
|
|
celsius(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The degrees are in fahrenheit(0) or in celsius(1)"
|
|
::= { sensorProbeTemperatureArrayPort1Entry 12 }
|
|
|
|
sensorProbeTemperatureArrayPort1DegreeRaw OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The raw degree data from the temperature sensor, slightly higher resolution"
|
|
::= { sensorProbeTemperatureArrayPort1Entry 14 }
|
|
|
|
sensorProbeTemperatureArrayPort1Offset OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset reading"
|
|
::= { sensorProbeTemperatureArrayPort1Entry 15 }
|
|
|
|
sensorProbeTemperatureArrayPort1URL OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor URL link."
|
|
::= { sensorProbeTemperatureArrayPort1Entry 16 }
|
|
|
|
sensorProbeTemperatureArrayPort1OpenURL OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cur-window(0),
|
|
new-window(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Open URL in this browser or open in a new window."
|
|
::= { sensorProbeTemperatureArrayPort1Entry 17 }
|
|
|
|
sensorProbeTemperatureArrayPort1DatacollectType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
average(1),
|
|
highest(2),
|
|
lowest(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Type of datacollect to collect."
|
|
::= { sensorProbeTemperatureArrayPort1Entry 18 }
|
|
|
|
sensorProbeTemperatureArrayPort1ContTimeHighCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in High Critical before accepting new Status."
|
|
::= { sensorProbeTemperatureArrayPort1Entry 19 }
|
|
|
|
sensorProbeTemperatureArrayPort1ContTimeHighWarning OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in High Warning before accepting new Status."
|
|
::= { sensorProbeTemperatureArrayPort1Entry 20 }
|
|
|
|
sensorProbeTemperatureArrayPort1ContTimeNormal OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Normal before accepting new Status."
|
|
::= { sensorProbeTemperatureArrayPort1Entry 21 }
|
|
|
|
sensorProbeTemperatureArrayPort1ContTimeLowWarning OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Low Warning before accepting new Status."
|
|
::= { sensorProbeTemperatureArrayPort1Entry 22 }
|
|
|
|
sensorProbeTemperatureArrayPort1ContTimeLowCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Low Critical before accepting new Status."
|
|
::= { sensorProbeTemperatureArrayPort1Entry 23 }
|
|
|
|
sensorProbeTemperatureArrayPort1ContTimeSensorError OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Sensor Error before accepting new Status."
|
|
::= { sensorProbeTemperatureArrayPort1Entry 24 }
|
|
|
|
sensorProbeTemperatureArrayPort1Calendar OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable the calendar filtering working hours of sensor."
|
|
::= { sensorProbeTemperatureArrayPort1Entry 25 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort1Index OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value for each sensor thermostat port."
|
|
::= { sensorProbeTemperatureArrayPort1Entry 26 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort1Description OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor thermostat"
|
|
::= { sensorProbeTemperatureArrayPort1Entry 27 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort1Value OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value in this sensor"
|
|
::= { sensorProbeTemperatureArrayPort1Entry 28 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort1Online OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
offline(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If this Sensor is currently online"
|
|
::= { sensorProbeTemperatureArrayPort1Entry 29 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort1GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To put online enter a 1, to take offline enter a 2"
|
|
::= { sensorProbeTemperatureArrayPort1Entry 30 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort1Mode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal(0),
|
|
time-bases(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To select the thermostat mode for working on time-bases(1) or normal(0)."
|
|
::= { sensorProbeTemperatureArrayPort1Entry 31 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort1RelayControlPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To select a relay port to be controled by this thermostat sensor."
|
|
::= { sensorProbeTemperatureArrayPort1Entry 32 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort1NormalAction1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile1: Thermostat normal action for controlling a relay sensor."
|
|
::= { sensorProbeTemperatureArrayPort1Entry 33 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort1HighLimit1 OBJECT-TYPE
|
|
SYNTAX INTEGER (-40..167)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile1: When this sersor higher than thermostat high limit, it will take a high limit action."
|
|
::= { sensorProbeTemperatureArrayPort1Entry 34 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort1HighLimitAction1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile1: Thermostat high limit action for controlling a relay sensor."
|
|
::= { sensorProbeTemperatureArrayPort1Entry 35 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort1LowLimit1 OBJECT-TYPE
|
|
SYNTAX INTEGER (-40..167)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile1: When this sersor higher than thermostat low limit, it will take a normal limit action."
|
|
::= { sensorProbeTemperatureArrayPort1Entry 36 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort1LowLimitAction1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile1: Thermostat low limit action for controlling a relay sensor."
|
|
::= { sensorProbeTemperatureArrayPort1Entry 37 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort1NormalAction2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile2: Thermostat normal action for controlling a relay sensor."
|
|
::= { sensorProbeTemperatureArrayPort1Entry 38 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort1HighLimit2 OBJECT-TYPE
|
|
SYNTAX INTEGER (-40..167)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile2: When this sersor higher than thermostat high limit, it will take a high limit action."
|
|
::= { sensorProbeTemperatureArrayPort1Entry 39 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort1HighLimitAction2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile2: Thermostat high limit action for controlling a relay sensor."
|
|
::= { sensorProbeTemperatureArrayPort1Entry 40 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort1LowLimit2 OBJECT-TYPE
|
|
SYNTAX INTEGER (-40..167)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile2: When this sersor higher than thermostat low limit, it will take a normal limit action."
|
|
::= { sensorProbeTemperatureArrayPort1Entry 41 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort1LowLimitAction2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile2: Thermostat low limit action for controlling a relay sensor."
|
|
::= { sensorProbeTemperatureArrayPort1Entry 42 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort1EnableTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time to enable on Thermostat"
|
|
::= { sensorProbeTemperatureArrayPort1Entry 43 }
|
|
|
|
sensorProbeTemperatureArrayPort2 OBJECT IDENTIFIER ::= { sensorProbeTemperatureArraySensor 2 }
|
|
sensorProbeTemperatureArrayPort2Number OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of port on the TemperatureArray."
|
|
::= { sensorProbeTemperatureArrayPort2 1 }
|
|
|
|
sensorProbeTemperatureArrayPort2Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorProbeTemperatureArrayPort2Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the data for every Switch Sensor in the SensorArray. Each row in the table contains data for a different Switch Sensor."
|
|
::= { sensorProbeTemperatureArrayPort2 2 }
|
|
|
|
sensorProbeTemperatureArrayPort2Entry OBJECT-TYPE
|
|
SYNTAX SensorProbeTemperatureArrayPort2Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorProbeTemperatureArrayPort2 Table"
|
|
INDEX { sensorProbeTemperatureArrayPort2Index }
|
|
::= { sensorProbeTemperatureArrayPort2Table 1 }
|
|
|
|
SensorProbeTemperatureArrayPort2Entry ::= SEQUENCE {
|
|
sensorProbeTemperatureArrayPort2Index
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort2Description
|
|
DisplayString,
|
|
sensorProbeTemperatureArrayPort2Value
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort2Status
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort2Online
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort2GoOnline
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort2HighWarning
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort2HighCritical
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort2LowWarning
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort2LowCritical
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort2Rearm
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort2DegreeType
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort2DegreeRaw
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort2Offset
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort2URL
|
|
DisplayString,
|
|
sensorProbeTemperatureArrayPort2OpenURL
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort2DatacollectType
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort2ContTimeHighCritical
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort2ContTimeHighWarning
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort2ContTimeNormal
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort2ContTimeLowWarning
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort2ContTimeLowCritical
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort2ContTimeSensorError
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort2Calendar
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort2Index
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort2Description
|
|
DisplayString,
|
|
sensorProbeThermostatTemperatureArrayPort2Value
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort2Online
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort2GoOnline
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort2Mode
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort2RelayControlPort
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort2NormalAction1
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort2HighLimit1
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort2HighLimitAction1
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort2LowLimit1
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort2LowLimitAction1
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort2NormalAction2
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort2HighLimit2
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort2HighLimitAction2
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort2LowLimit2
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort2LowLimitAction2
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort2EnableTime
|
|
DisplayString
|
|
}
|
|
|
|
sensorProbeTemperatureArrayPort2Index OBJECT-TYPE
|
|
SYNTAX INTEGER (0..7)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value for each sensor TemperatureArray port."
|
|
::= { sensorProbeTemperatureArrayPort2Entry 1 }
|
|
|
|
sensorProbeTemperatureArrayPort2Description OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor TemperatureArray"
|
|
::= { sensorProbeTemperatureArrayPort2Entry 2 }
|
|
|
|
sensorProbeTemperatureArrayPort2Value OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value in this sensor"
|
|
::= { sensorProbeTemperatureArrayPort2Entry 3 }
|
|
|
|
sensorProbeTemperatureArrayPort2Status OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highWarning(3),
|
|
highCritical(4),
|
|
lowWarning(5),
|
|
lowCritical(6),
|
|
sensorError(7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor"
|
|
::= { sensorProbeTemperatureArrayPort2Entry 4 }
|
|
|
|
sensorProbeTemperatureArrayPort2Online OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
offline(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If this Sensor is currently online"
|
|
::= { sensorProbeTemperatureArrayPort2Entry 5 }
|
|
|
|
sensorProbeTemperatureArrayPort2GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To put online enter a 1, to take offline enter a 2"
|
|
::= { sensorProbeTemperatureArrayPort2Entry 6 }
|
|
|
|
sensorProbeTemperatureArrayPort2HighWarning OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How hot this sensor gets before it sends a warning"
|
|
::= { sensorProbeTemperatureArrayPort2Entry 7 }
|
|
|
|
sensorProbeTemperatureArrayPort2HighCritical OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How hot this sensor gets before it sends a critical event"
|
|
::= { sensorProbeTemperatureArrayPort2Entry 8 }
|
|
|
|
sensorProbeTemperatureArrayPort2LowWarning OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How cold this sensor gets before it sends a warning"
|
|
::= { sensorProbeTemperatureArrayPort2Entry 9 }
|
|
|
|
sensorProbeTemperatureArrayPort2LowCritical OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How cold this sensor gets before it sends a critical event"
|
|
::= { sensorProbeTemperatureArrayPort2Entry 10 }
|
|
|
|
sensorProbeTemperatureArrayPort2Rearm OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of degrees to rearm the status. For example if status goes from normal to warning, the temp must go down spTempRearm degrees below warning before the status goes to normal"
|
|
::= { sensorProbeTemperatureArrayPort2Entry 11 }
|
|
|
|
sensorProbeTemperatureArrayPort2DegreeType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
fahr(0),
|
|
celsius(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The degrees are in fahrenheit(0) or in celsius(1)"
|
|
::= { sensorProbeTemperatureArrayPort2Entry 12 }
|
|
|
|
sensorProbeTemperatureArrayPort2DegreeRaw OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The raw degree data from the temperature sensor, slightly higher resolution"
|
|
::= { sensorProbeTemperatureArrayPort2Entry 14 }
|
|
|
|
sensorProbeTemperatureArrayPort2Offset OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset reading"
|
|
::= { sensorProbeTemperatureArrayPort2Entry 15 }
|
|
|
|
sensorProbeTemperatureArrayPort2URL OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor URL link."
|
|
::= { sensorProbeTemperatureArrayPort2Entry 16 }
|
|
|
|
sensorProbeTemperatureArrayPort2OpenURL OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cur-window(0),
|
|
new-window(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Open URL in this browser or open in a new window."
|
|
::= { sensorProbeTemperatureArrayPort2Entry 17 }
|
|
|
|
sensorProbeTemperatureArrayPort2DatacollectType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
average(1),
|
|
highest(2),
|
|
lowest(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Type of datacollect to collect."
|
|
::= { sensorProbeTemperatureArrayPort2Entry 18 }
|
|
|
|
sensorProbeTemperatureArrayPort2ContTimeHighCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in High Critical before accepting new Status."
|
|
::= { sensorProbeTemperatureArrayPort2Entry 19 }
|
|
|
|
sensorProbeTemperatureArrayPort2ContTimeHighWarning OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in High Warning before accepting new Status."
|
|
::= { sensorProbeTemperatureArrayPort2Entry 20 }
|
|
|
|
sensorProbeTemperatureArrayPort2ContTimeNormal OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Normal before accepting new Status."
|
|
::= { sensorProbeTemperatureArrayPort2Entry 21 }
|
|
|
|
sensorProbeTemperatureArrayPort2ContTimeLowWarning OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Low Warning before accepting new Status."
|
|
::= { sensorProbeTemperatureArrayPort2Entry 22 }
|
|
|
|
sensorProbeTemperatureArrayPort2ContTimeLowCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Low Critical before accepting new Status."
|
|
::= { sensorProbeTemperatureArrayPort2Entry 23 }
|
|
|
|
sensorProbeTemperatureArrayPort2ContTimeSensorError OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Sensor Error before accepting new Status."
|
|
::= { sensorProbeTemperatureArrayPort2Entry 24 }
|
|
|
|
sensorProbeTemperatureArrayPort2Calendar OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable the calendar filtering working hours of sensor."
|
|
::= { sensorProbeTemperatureArrayPort2Entry 25 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort2Index OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value for each sensor thermostat port."
|
|
::= { sensorProbeTemperatureArrayPort2Entry 26 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort2Description OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor thermostat"
|
|
::= { sensorProbeTemperatureArrayPort2Entry 27 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort2Value OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value in this sensor"
|
|
::= { sensorProbeTemperatureArrayPort2Entry 28 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort2Online OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
offline(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If this Sensor is currently online"
|
|
::= { sensorProbeTemperatureArrayPort2Entry 29 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort2GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To put online enter a 1, to take offline enter a 2"
|
|
::= { sensorProbeTemperatureArrayPort2Entry 30 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort2Mode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal(0),
|
|
time-bases(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To select the thermostat mode for working on time-bases(1) or normal(0)."
|
|
::= { sensorProbeTemperatureArrayPort2Entry 31 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort2RelayControlPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To select a relay port to be controled by this thermostat sensor."
|
|
::= { sensorProbeTemperatureArrayPort2Entry 32 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort2NormalAction1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile1: Thermostat normal action for controlling a relay sensor."
|
|
::= { sensorProbeTemperatureArrayPort2Entry 33 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort2HighLimit1 OBJECT-TYPE
|
|
SYNTAX INTEGER (-40..167)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile1: When this sersor higher than thermostat high limit, it will take a high limit action."
|
|
::= { sensorProbeTemperatureArrayPort2Entry 34 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort2HighLimitAction1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile1: Thermostat high limit action for controlling a relay sensor."
|
|
::= { sensorProbeTemperatureArrayPort2Entry 35 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort2LowLimit1 OBJECT-TYPE
|
|
SYNTAX INTEGER (-40..167)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile1: When this sersor higher than thermostat low limit, it will take a normal limit action."
|
|
::= { sensorProbeTemperatureArrayPort2Entry 36 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort2LowLimitAction1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile1: Thermostat low limit action for controlling a relay sensor."
|
|
::= { sensorProbeTemperatureArrayPort2Entry 37 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort2NormalAction2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile2: Thermostat normal action for controlling a relay sensor."
|
|
::= { sensorProbeTemperatureArrayPort2Entry 38 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort2HighLimit2 OBJECT-TYPE
|
|
SYNTAX INTEGER (-40..167)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile2: When this sersor higher than thermostat high limit, it will take a high limit action."
|
|
::= { sensorProbeTemperatureArrayPort2Entry 39 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort2HighLimitAction2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile2: Thermostat high limit action for controlling a relay sensor."
|
|
::= { sensorProbeTemperatureArrayPort2Entry 40 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort2LowLimit2 OBJECT-TYPE
|
|
SYNTAX INTEGER (-40..167)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile2: When this sersor higher than thermostat low limit, it will take a normal limit action."
|
|
::= { sensorProbeTemperatureArrayPort2Entry 41 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort2LowLimitAction2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile2: Thermostat low limit action for controlling a relay sensor."
|
|
::= { sensorProbeTemperatureArrayPort2Entry 42 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort2EnableTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time to enable on Thermostat"
|
|
::= { sensorProbeTemperatureArrayPort2Entry 43 }
|
|
|
|
sensorProbeTemperatureArrayPort3 OBJECT IDENTIFIER ::= { sensorProbeTemperatureArraySensor 3 }
|
|
sensorProbeTemperatureArrayPort3Number OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of port on the TemperatureArray."
|
|
::= { sensorProbeTemperatureArrayPort3 1 }
|
|
|
|
sensorProbeTemperatureArrayPort3Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorProbeTemperatureArrayPort3Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the data for every Switch Sensor in the SensorArray. Each row in the table contains data for a different Switch Sensor."
|
|
::= { sensorProbeTemperatureArrayPort3 2 }
|
|
|
|
sensorProbeTemperatureArrayPort3Entry OBJECT-TYPE
|
|
SYNTAX SensorProbeTemperatureArrayPort3Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorProbeTemperatureArrayPort3 Table"
|
|
INDEX { sensorProbeTemperatureArrayPort3Index }
|
|
::= { sensorProbeTemperatureArrayPort3Table 1 }
|
|
|
|
SensorProbeTemperatureArrayPort3Entry ::= SEQUENCE {
|
|
sensorProbeTemperatureArrayPort3Index
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort3Description
|
|
DisplayString,
|
|
sensorProbeTemperatureArrayPort3Value
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort3Status
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort3Online
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort3GoOnline
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort3HighWarning
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort3HighCritical
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort3LowWarning
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort3LowCritical
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort3Rearm
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort3DegreeType
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort3DegreeRaw
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort3Offset
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort3URL
|
|
DisplayString,
|
|
sensorProbeTemperatureArrayPort3OpenURL
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort3DatacollectType
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort3ContTimeHighCritical
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort3ContTimeHighWarning
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort3ContTimeNormal
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort3ContTimeLowWarning
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort3ContTimeLowCritical
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort3ContTimeSensorError
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort3Calendar
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort3Index
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort3Description
|
|
DisplayString,
|
|
sensorProbeThermostatTemperatureArrayPort3Value
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort3Online
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort3GoOnline
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort3Mode
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort3RelayControlPort
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort3NormalAction1
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort3HighLimit1
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort3HighLimitAction1
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort3LowLimit1
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort3LowLimitAction1
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort3NormalAction2
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort3HighLimit2
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort3HighLimitAction2
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort3LowLimit2
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort3LowLimitAction2
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort3EnableTime
|
|
DisplayString
|
|
}
|
|
|
|
sensorProbeTemperatureArrayPort3Index OBJECT-TYPE
|
|
SYNTAX INTEGER (0..7)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value for each sensor TemperatureArray port."
|
|
::= { sensorProbeTemperatureArrayPort3Entry 1 }
|
|
|
|
sensorProbeTemperatureArrayPort3Description OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor TemperatureArray"
|
|
::= { sensorProbeTemperatureArrayPort3Entry 2 }
|
|
|
|
sensorProbeTemperatureArrayPort3Value OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value in this sensor"
|
|
::= { sensorProbeTemperatureArrayPort3Entry 3 }
|
|
|
|
sensorProbeTemperatureArrayPort3Status OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highWarning(3),
|
|
highCritical(4),
|
|
lowWarning(5),
|
|
lowCritical(6),
|
|
sensorError(7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor"
|
|
::= { sensorProbeTemperatureArrayPort3Entry 4 }
|
|
|
|
sensorProbeTemperatureArrayPort3Online OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
offline(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If this Sensor is currently online"
|
|
::= { sensorProbeTemperatureArrayPort3Entry 5 }
|
|
|
|
sensorProbeTemperatureArrayPort3GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To put online enter a 1, to take offline enter a 2"
|
|
::= { sensorProbeTemperatureArrayPort3Entry 6 }
|
|
|
|
sensorProbeTemperatureArrayPort3HighWarning OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How hot this sensor gets before it sends a warning"
|
|
::= { sensorProbeTemperatureArrayPort3Entry 7 }
|
|
|
|
sensorProbeTemperatureArrayPort3HighCritical OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How hot this sensor gets before it sends a critical event"
|
|
::= { sensorProbeTemperatureArrayPort3Entry 8 }
|
|
|
|
sensorProbeTemperatureArrayPort3LowWarning OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How cold this sensor gets before it sends a warning"
|
|
::= { sensorProbeTemperatureArrayPort3Entry 9 }
|
|
|
|
sensorProbeTemperatureArrayPort3LowCritical OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How cold this sensor gets before it sends a critical event"
|
|
::= { sensorProbeTemperatureArrayPort3Entry 10 }
|
|
|
|
sensorProbeTemperatureArrayPort3Rearm OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of degrees to rearm the status. For example if status goes from normal to warning, the temp must go down spTempRearm degrees below warning before the status goes to normal"
|
|
::= { sensorProbeTemperatureArrayPort3Entry 11 }
|
|
|
|
sensorProbeTemperatureArrayPort3DegreeType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
fahr(0),
|
|
celsius(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The degrees are in fahrenheit(0) or in celsius(1)"
|
|
::= { sensorProbeTemperatureArrayPort3Entry 12 }
|
|
|
|
sensorProbeTemperatureArrayPort3DegreeRaw OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The raw degree data from the temperature sensor, slightly higher resolution"
|
|
::= { sensorProbeTemperatureArrayPort3Entry 14 }
|
|
|
|
sensorProbeTemperatureArrayPort3Offset OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset reading"
|
|
::= { sensorProbeTemperatureArrayPort3Entry 15 }
|
|
|
|
sensorProbeTemperatureArrayPort3URL OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor URL link."
|
|
::= { sensorProbeTemperatureArrayPort3Entry 16 }
|
|
|
|
sensorProbeTemperatureArrayPort3OpenURL OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cur-window(0),
|
|
new-window(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Open URL in this browser or open in a new window."
|
|
::= { sensorProbeTemperatureArrayPort3Entry 17 }
|
|
|
|
sensorProbeTemperatureArrayPort3DatacollectType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
average(1),
|
|
highest(2),
|
|
lowest(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Type of datacollect to collect."
|
|
::= { sensorProbeTemperatureArrayPort3Entry 18 }
|
|
|
|
sensorProbeTemperatureArrayPort3ContTimeHighCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in High Critical before accepting new Status."
|
|
::= { sensorProbeTemperatureArrayPort3Entry 19 }
|
|
|
|
sensorProbeTemperatureArrayPort3ContTimeHighWarning OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in High Warning before accepting new Status."
|
|
::= { sensorProbeTemperatureArrayPort3Entry 20 }
|
|
|
|
sensorProbeTemperatureArrayPort3ContTimeNormal OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Normal before accepting new Status."
|
|
::= { sensorProbeTemperatureArrayPort3Entry 21 }
|
|
|
|
sensorProbeTemperatureArrayPort3ContTimeLowWarning OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Low Warning before accepting new Status."
|
|
::= { sensorProbeTemperatureArrayPort3Entry 22 }
|
|
|
|
sensorProbeTemperatureArrayPort3ContTimeLowCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Low Critical before accepting new Status."
|
|
::= { sensorProbeTemperatureArrayPort3Entry 23 }
|
|
|
|
sensorProbeTemperatureArrayPort3ContTimeSensorError OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Sensor Error before accepting new Status."
|
|
::= { sensorProbeTemperatureArrayPort3Entry 24 }
|
|
|
|
sensorProbeTemperatureArrayPort3Calendar OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable the calendar filtering working hours of sensor."
|
|
::= { sensorProbeTemperatureArrayPort3Entry 25 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort3Index OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value for each sensor thermostat port."
|
|
::= { sensorProbeTemperatureArrayPort3Entry 26 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort3Description OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor thermostat"
|
|
::= { sensorProbeTemperatureArrayPort3Entry 27 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort3Value OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value in this sensor"
|
|
::= { sensorProbeTemperatureArrayPort3Entry 28 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort3Online OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
offline(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If this Sensor is currently online"
|
|
::= { sensorProbeTemperatureArrayPort3Entry 29 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort3GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To put online enter a 1, to take offline enter a 2"
|
|
::= { sensorProbeTemperatureArrayPort3Entry 30 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort3Mode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal(0),
|
|
time-bases(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To select the thermostat mode for working on time-bases(1) or normal(0)."
|
|
::= { sensorProbeTemperatureArrayPort3Entry 31 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort3RelayControlPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To select a relay port to be controled by this thermostat sensor."
|
|
::= { sensorProbeTemperatureArrayPort3Entry 32 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort3NormalAction1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile1: Thermostat normal action for controlling a relay sensor."
|
|
::= { sensorProbeTemperatureArrayPort3Entry 33 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort3HighLimit1 OBJECT-TYPE
|
|
SYNTAX INTEGER (-40..167)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile1: When this sersor higher than thermostat high limit, it will take a high limit action."
|
|
::= { sensorProbeTemperatureArrayPort3Entry 34 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort3HighLimitAction1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile1: Thermostat high limit action for controlling a relay sensor."
|
|
::= { sensorProbeTemperatureArrayPort3Entry 35 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort3LowLimit1 OBJECT-TYPE
|
|
SYNTAX INTEGER (-40..167)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile1: When this sersor higher than thermostat low limit, it will take a normal limit action."
|
|
::= { sensorProbeTemperatureArrayPort3Entry 36 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort3LowLimitAction1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile1: Thermostat low limit action for controlling a relay sensor."
|
|
::= { sensorProbeTemperatureArrayPort3Entry 37 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort3NormalAction2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile2: Thermostat normal action for controlling a relay sensor."
|
|
::= { sensorProbeTemperatureArrayPort3Entry 38 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort3HighLimit2 OBJECT-TYPE
|
|
SYNTAX INTEGER (-40..167)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile2: When this sersor higher than thermostat high limit, it will take a high limit action."
|
|
::= { sensorProbeTemperatureArrayPort3Entry 39 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort3HighLimitAction2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile2: Thermostat high limit action for controlling a relay sensor."
|
|
::= { sensorProbeTemperatureArrayPort3Entry 40 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort3LowLimit2 OBJECT-TYPE
|
|
SYNTAX INTEGER (-40..167)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile2: When this sersor higher than thermostat low limit, it will take a normal limit action."
|
|
::= { sensorProbeTemperatureArrayPort3Entry 41 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort3LowLimitAction2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile2: Thermostat low limit action for controlling a relay sensor."
|
|
::= { sensorProbeTemperatureArrayPort3Entry 42 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort3EnableTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time to enable on Thermostat"
|
|
::= { sensorProbeTemperatureArrayPort3Entry 43 }
|
|
|
|
|
|
sensorProbeTemperatureArrayPort4 OBJECT IDENTIFIER ::= { sensorProbeTemperatureArraySensor 4 }
|
|
sensorProbeTemperatureArrayPort4Number OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of port on the TemperatureArray."
|
|
::= { sensorProbeTemperatureArrayPort4 1 }
|
|
|
|
sensorProbeTemperatureArrayPort4Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorProbeTemperatureArrayPort4Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the data for every Switch Sensor in the SensorArray. Each row in the table contains data for a different Switch Sensor."
|
|
::= { sensorProbeTemperatureArrayPort4 2 }
|
|
|
|
sensorProbeTemperatureArrayPort4Entry OBJECT-TYPE
|
|
SYNTAX SensorProbeTemperatureArrayPort4Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorProbeTemperatureArrayPort4 Table"
|
|
INDEX { sensorProbeTemperatureArrayPort4Index }
|
|
::= { sensorProbeTemperatureArrayPort4Table 1 }
|
|
|
|
SensorProbeTemperatureArrayPort4Entry ::= SEQUENCE {
|
|
sensorProbeTemperatureArrayPort4Index
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort4Description
|
|
DisplayString,
|
|
sensorProbeTemperatureArrayPort4Value
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort4Status
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort4Online
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort4GoOnline
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort4HighWarning
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort4HighCritical
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort4LowWarning
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort4LowCritical
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort4Rearm
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort4DegreeType
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort4DegreeRaw
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort4Offset
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort4URL
|
|
DisplayString,
|
|
sensorProbeTemperatureArrayPort4OpenURL
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort4DatacollectType
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort4ContTimeHighCritical
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort4ContTimeHighWarning
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort4ContTimeNormal
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort4ContTimeLowWarning
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort4ContTimeLowCritical
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort4ContTimeSensorError
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort4Calendar
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort4Index
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort4Description
|
|
DisplayString,
|
|
sensorProbeThermostatTemperatureArrayPort4Value
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort4Online
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort4GoOnline
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort4Mode
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort4RelayControlPort
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort4NormalAction1
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort4HighLimit1
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort4HighLimitAction1
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort4LowLimit1
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort4LowLimitAction1
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort4NormalAction2
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort4HighLimit2
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort4HighLimitAction2
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort4LowLimit2
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort4LowLimitAction2
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort4EnableTime
|
|
DisplayString
|
|
}
|
|
|
|
sensorProbeTemperatureArrayPort4Index OBJECT-TYPE
|
|
SYNTAX INTEGER (0..7)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value for each sensor TemperatureArray port."
|
|
::= { sensorProbeTemperatureArrayPort4Entry 1 }
|
|
|
|
sensorProbeTemperatureArrayPort4Description OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor TemperatureArray"
|
|
::= { sensorProbeTemperatureArrayPort4Entry 2 }
|
|
|
|
sensorProbeTemperatureArrayPort4Value OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value in this sensor"
|
|
::= { sensorProbeTemperatureArrayPort4Entry 3 }
|
|
|
|
sensorProbeTemperatureArrayPort4Status OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highWarning(3),
|
|
highCritical(4),
|
|
lowWarning(5),
|
|
lowCritical(6),
|
|
sensorError(7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor"
|
|
::= { sensorProbeTemperatureArrayPort4Entry 4 }
|
|
|
|
sensorProbeTemperatureArrayPort4Online OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
offline(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If this Sensor is currently online"
|
|
::= { sensorProbeTemperatureArrayPort4Entry 5 }
|
|
|
|
sensorProbeTemperatureArrayPort4GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To put online enter a 1, to take offline enter a 2"
|
|
::= { sensorProbeTemperatureArrayPort4Entry 6 }
|
|
|
|
sensorProbeTemperatureArrayPort4HighWarning OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How hot this sensor gets before it sends a warning"
|
|
::= { sensorProbeTemperatureArrayPort4Entry 7 }
|
|
|
|
sensorProbeTemperatureArrayPort4HighCritical OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How hot this sensor gets before it sends a critical event"
|
|
::= { sensorProbeTemperatureArrayPort4Entry 8 }
|
|
|
|
sensorProbeTemperatureArrayPort4LowWarning OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How cold this sensor gets before it sends a warning"
|
|
::= { sensorProbeTemperatureArrayPort4Entry 9 }
|
|
|
|
sensorProbeTemperatureArrayPort4LowCritical OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How cold this sensor gets before it sends a critical event"
|
|
::= { sensorProbeTemperatureArrayPort4Entry 10 }
|
|
|
|
sensorProbeTemperatureArrayPort4Rearm OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of degrees to rearm the status. For example if status goes from normal to warning, the temp must go down spTempRearm degrees below warning before the status goes to normal"
|
|
::= { sensorProbeTemperatureArrayPort4Entry 11 }
|
|
|
|
sensorProbeTemperatureArrayPort4DegreeType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
fahr(0),
|
|
celsius(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The degrees are in fahrenheit(0) or in celsius(1)"
|
|
::= { sensorProbeTemperatureArrayPort4Entry 12 }
|
|
|
|
sensorProbeTemperatureArrayPort4DegreeRaw OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The raw degree data from the temperature sensor, slightly higher resolution"
|
|
::= { sensorProbeTemperatureArrayPort4Entry 14 }
|
|
|
|
sensorProbeTemperatureArrayPort4Offset OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset reading"
|
|
::= { sensorProbeTemperatureArrayPort4Entry 15 }
|
|
|
|
sensorProbeTemperatureArrayPort4URL OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor URL link."
|
|
::= { sensorProbeTemperatureArrayPort4Entry 16 }
|
|
|
|
sensorProbeTemperatureArrayPort4OpenURL OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cur-window(0),
|
|
new-window(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Open URL in this browser or open in a new window."
|
|
::= { sensorProbeTemperatureArrayPort4Entry 17 }
|
|
|
|
sensorProbeTemperatureArrayPort4DatacollectType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
average(1),
|
|
highest(2),
|
|
lowest(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Type of datacollect to collect."
|
|
::= { sensorProbeTemperatureArrayPort4Entry 18 }
|
|
|
|
sensorProbeTemperatureArrayPort4ContTimeHighCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in High Critical before accepting new Status."
|
|
::= { sensorProbeTemperatureArrayPort4Entry 19 }
|
|
|
|
sensorProbeTemperatureArrayPort4ContTimeHighWarning OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in High Warning before accepting new Status."
|
|
::= { sensorProbeTemperatureArrayPort4Entry 20 }
|
|
|
|
sensorProbeTemperatureArrayPort4ContTimeNormal OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Normal before accepting new Status."
|
|
::= { sensorProbeTemperatureArrayPort4Entry 21 }
|
|
|
|
sensorProbeTemperatureArrayPort4ContTimeLowWarning OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Low Warning before accepting new Status."
|
|
::= { sensorProbeTemperatureArrayPort4Entry 22 }
|
|
|
|
sensorProbeTemperatureArrayPort4ContTimeLowCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Low Critical before accepting new Status."
|
|
::= { sensorProbeTemperatureArrayPort4Entry 23 }
|
|
|
|
sensorProbeTemperatureArrayPort4ContTimeSensorError OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Sensor Error before accepting new Status."
|
|
::= { sensorProbeTemperatureArrayPort4Entry 24 }
|
|
|
|
sensorProbeTemperatureArrayPort4Calendar OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable the calendar filtering working hours of sensor."
|
|
::= { sensorProbeTemperatureArrayPort4Entry 25 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort4Index OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value for each sensor thermostat port."
|
|
::= { sensorProbeTemperatureArrayPort4Entry 26 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort4Description OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor thermostat"
|
|
::= { sensorProbeTemperatureArrayPort4Entry 27 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort4Value OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value in this sensor"
|
|
::= { sensorProbeTemperatureArrayPort4Entry 28 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort4Online OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
offline(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If this Sensor is currently online"
|
|
::= { sensorProbeTemperatureArrayPort4Entry 29 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort4GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To put online enter a 1, to take offline enter a 2"
|
|
::= { sensorProbeTemperatureArrayPort4Entry 30 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort4Mode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal(0),
|
|
time-bases(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To select the thermostat mode for working on time-bases(1) or normal(0)."
|
|
::= { sensorProbeTemperatureArrayPort4Entry 31 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort4RelayControlPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To select a relay port to be controled by this thermostat sensor."
|
|
::= { sensorProbeTemperatureArrayPort4Entry 32 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort4NormalAction1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile1: Thermostat normal action for controlling a relay sensor."
|
|
::= { sensorProbeTemperatureArrayPort4Entry 33 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort4HighLimit1 OBJECT-TYPE
|
|
SYNTAX INTEGER (-40..167)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile1: When this sersor higher than thermostat high limit, it will take a high limit action."
|
|
::= { sensorProbeTemperatureArrayPort4Entry 34 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort4HighLimitAction1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile1: Thermostat high limit action for controlling a relay sensor."
|
|
::= { sensorProbeTemperatureArrayPort4Entry 35 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort4LowLimit1 OBJECT-TYPE
|
|
SYNTAX INTEGER (-40..167)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile1: When this sersor higher than thermostat low limit, it will take a normal limit action."
|
|
::= { sensorProbeTemperatureArrayPort4Entry 36 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort4LowLimitAction1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile1: Thermostat low limit action for controlling a relay sensor."
|
|
::= { sensorProbeTemperatureArrayPort4Entry 37 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort4NormalAction2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile2: Thermostat normal action for controlling a relay sensor."
|
|
::= { sensorProbeTemperatureArrayPort4Entry 38 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort4HighLimit2 OBJECT-TYPE
|
|
SYNTAX INTEGER (-40..167)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile2: When this sersor higher than thermostat high limit, it will take a high limit action."
|
|
::= { sensorProbeTemperatureArrayPort4Entry 39 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort4HighLimitAction2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile2: Thermostat high limit action for controlling a relay sensor."
|
|
::= { sensorProbeTemperatureArrayPort4Entry 40 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort4LowLimit2 OBJECT-TYPE
|
|
SYNTAX INTEGER (-40..167)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile2: When this sersor higher than thermostat low limit, it will take a normal limit action."
|
|
::= { sensorProbeTemperatureArrayPort4Entry 41 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort4LowLimitAction2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile2: Thermostat low limit action for controlling a relay sensor."
|
|
::= { sensorProbeTemperatureArrayPort4Entry 42 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort4EnableTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time to enable on Thermostat"
|
|
::= { sensorProbeTemperatureArrayPort4Entry 43 }
|
|
|
|
sensorProbeTemperatureArrayPort5 OBJECT IDENTIFIER ::= { sensorProbeTemperatureArraySensor 5 }
|
|
sensorProbeTemperatureArrayPort5Number OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of port on the TemperatureArray."
|
|
::= { sensorProbeTemperatureArrayPort5 1 }
|
|
|
|
sensorProbeTemperatureArrayPort5Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorProbeTemperatureArrayPort5Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the data for every Switch Sensor in the SensorArray. Each row in the table contains data for a different Switch Sensor."
|
|
::= { sensorProbeTemperatureArrayPort5 2 }
|
|
|
|
sensorProbeTemperatureArrayPort5Entry OBJECT-TYPE
|
|
SYNTAX SensorProbeTemperatureArrayPort5Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorProbeTemperatureArrayPort5 Table"
|
|
INDEX { sensorProbeTemperatureArrayPort5Index }
|
|
::= { sensorProbeTemperatureArrayPort5Table 1 }
|
|
|
|
SensorProbeTemperatureArrayPort5Entry ::= SEQUENCE {
|
|
sensorProbeTemperatureArrayPort5Index
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort5Description
|
|
DisplayString,
|
|
sensorProbeTemperatureArrayPort5Value
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort5Status
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort5Online
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort5GoOnline
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort5HighWarning
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort5HighCritical
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort5LowWarning
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort5LowCritical
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort5Rearm
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort5DegreeType
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort5DegreeRaw
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort5Offset
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort5URL
|
|
DisplayString,
|
|
sensorProbeTemperatureArrayPort5OpenURL
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort5DatacollectType
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort5ContTimeHighCritical
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort5ContTimeHighWarning
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort5ContTimeNormal
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort5ContTimeLowWarning
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort5ContTimeLowCritical
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort5ContTimeSensorError
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort5Calendar
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort5Index
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort5Description
|
|
DisplayString,
|
|
sensorProbeThermostatTemperatureArrayPort5Value
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort5Online
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort5GoOnline
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort5Mode
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort5RelayControlPort
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort5NormalAction1
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort5HighLimit1
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort5HighLimitAction1
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort5LowLimit1
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort5LowLimitAction1
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort5NormalAction2
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort5HighLimit2
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort5HighLimitAction2
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort5LowLimit2
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort5LowLimitAction2
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort5EnableTime
|
|
DisplayString
|
|
}
|
|
|
|
sensorProbeTemperatureArrayPort5Index OBJECT-TYPE
|
|
SYNTAX INTEGER (0..7)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value for each sensor TemperatureArray port."
|
|
::= { sensorProbeTemperatureArrayPort5Entry 1 }
|
|
|
|
sensorProbeTemperatureArrayPort5Description OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor TemperatureArray"
|
|
::= { sensorProbeTemperatureArrayPort5Entry 2 }
|
|
|
|
sensorProbeTemperatureArrayPort5Value OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value in this sensor"
|
|
::= { sensorProbeTemperatureArrayPort5Entry 3 }
|
|
|
|
sensorProbeTemperatureArrayPort5Status OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highWarning(3),
|
|
highCritical(4),
|
|
lowWarning(5),
|
|
lowCritical(6),
|
|
sensorError(7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor"
|
|
::= { sensorProbeTemperatureArrayPort5Entry 4 }
|
|
|
|
sensorProbeTemperatureArrayPort5Online OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
offline(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If this Sensor is currently online"
|
|
::= { sensorProbeTemperatureArrayPort5Entry 5 }
|
|
|
|
sensorProbeTemperatureArrayPort5GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To put online enter a 1, to take offline enter a 2"
|
|
::= { sensorProbeTemperatureArrayPort5Entry 6 }
|
|
|
|
sensorProbeTemperatureArrayPort5HighWarning OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How hot this sensor gets before it sends a warning"
|
|
::= { sensorProbeTemperatureArrayPort5Entry 7 }
|
|
|
|
sensorProbeTemperatureArrayPort5HighCritical OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How hot this sensor gets before it sends a critical event"
|
|
::= { sensorProbeTemperatureArrayPort5Entry 8 }
|
|
|
|
sensorProbeTemperatureArrayPort5LowWarning OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How cold this sensor gets before it sends a warning"
|
|
::= { sensorProbeTemperatureArrayPort5Entry 9 }
|
|
|
|
sensorProbeTemperatureArrayPort5LowCritical OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How cold this sensor gets before it sends a critical event"
|
|
::= { sensorProbeTemperatureArrayPort5Entry 10 }
|
|
|
|
sensorProbeTemperatureArrayPort5Rearm OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of degrees to rearm the status. For example if status goes from normal to warning, the temp must go down spTempRearm degrees below warning before the status goes to normal"
|
|
::= { sensorProbeTemperatureArrayPort5Entry 11 }
|
|
|
|
sensorProbeTemperatureArrayPort5DegreeType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
fahr(0),
|
|
celsius(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The degrees are in fahrenheit(0) or in celsius(1)"
|
|
::= { sensorProbeTemperatureArrayPort5Entry 12 }
|
|
|
|
sensorProbeTemperatureArrayPort5DegreeRaw OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The raw degree data from the temperature sensor, slightly higher resolution"
|
|
::= { sensorProbeTemperatureArrayPort5Entry 14 }
|
|
|
|
sensorProbeTemperatureArrayPort5Offset OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset reading"
|
|
::= { sensorProbeTemperatureArrayPort5Entry 15 }
|
|
|
|
sensorProbeTemperatureArrayPort5URL OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor URL link."
|
|
::= { sensorProbeTemperatureArrayPort5Entry 16 }
|
|
|
|
sensorProbeTemperatureArrayPort5OpenURL OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cur-window(0),
|
|
new-window(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Open URL in this browser or open in a new window."
|
|
::= { sensorProbeTemperatureArrayPort5Entry 17 }
|
|
|
|
sensorProbeTemperatureArrayPort5DatacollectType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
average(1),
|
|
highest(2),
|
|
lowest(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Type of datacollect to collect."
|
|
::= { sensorProbeTemperatureArrayPort5Entry 18 }
|
|
|
|
sensorProbeTemperatureArrayPort5ContTimeHighCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in High Critical before accepting new Status."
|
|
::= { sensorProbeTemperatureArrayPort5Entry 19 }
|
|
|
|
sensorProbeTemperatureArrayPort5ContTimeHighWarning OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in High Warning before accepting new Status."
|
|
::= { sensorProbeTemperatureArrayPort5Entry 20 }
|
|
|
|
sensorProbeTemperatureArrayPort5ContTimeNormal OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Normal before accepting new Status."
|
|
::= { sensorProbeTemperatureArrayPort5Entry 21 }
|
|
|
|
sensorProbeTemperatureArrayPort5ContTimeLowWarning OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Low Warning before accepting new Status."
|
|
::= { sensorProbeTemperatureArrayPort5Entry 22 }
|
|
|
|
sensorProbeTemperatureArrayPort5ContTimeLowCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Low Critical before accepting new Status."
|
|
::= { sensorProbeTemperatureArrayPort5Entry 23 }
|
|
|
|
sensorProbeTemperatureArrayPort5ContTimeSensorError OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Sensor Error before accepting new Status."
|
|
::= { sensorProbeTemperatureArrayPort5Entry 24 }
|
|
|
|
sensorProbeTemperatureArrayPort5Calendar OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable the calendar filtering working hours of sensor."
|
|
::= { sensorProbeTemperatureArrayPort5Entry 25 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort5Index OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value for each sensor thermostat port."
|
|
::= { sensorProbeTemperatureArrayPort5Entry 26 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort5Description OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor thermostat"
|
|
::= { sensorProbeTemperatureArrayPort5Entry 27 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort5Value OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value in this sensor"
|
|
::= { sensorProbeTemperatureArrayPort5Entry 28 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort5Online OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
offline(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If this Sensor is currently online"
|
|
::= { sensorProbeTemperatureArrayPort5Entry 29 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort5GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To put online enter a 1, to take offline enter a 2"
|
|
::= { sensorProbeTemperatureArrayPort5Entry 30 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort5Mode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal(0),
|
|
time-bases(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To select the thermostat mode for working on time-bases(1) or normal(0)."
|
|
::= { sensorProbeTemperatureArrayPort5Entry 31 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort5RelayControlPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To select a relay port to be controled by this thermostat sensor."
|
|
::= { sensorProbeTemperatureArrayPort5Entry 32 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort5NormalAction1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile1: Thermostat normal action for controlling a relay sensor."
|
|
::= { sensorProbeTemperatureArrayPort5Entry 33 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort5HighLimit1 OBJECT-TYPE
|
|
SYNTAX INTEGER (-40..167)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile1: When this sersor higher than thermostat high limit, it will take a high limit action."
|
|
::= { sensorProbeTemperatureArrayPort5Entry 34 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort5HighLimitAction1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile1: Thermostat high limit action for controlling a relay sensor."
|
|
::= { sensorProbeTemperatureArrayPort5Entry 35 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort5LowLimit1 OBJECT-TYPE
|
|
SYNTAX INTEGER (-40..167)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile1: When this sersor higher than thermostat low limit, it will take a normal limit action."
|
|
::= { sensorProbeTemperatureArrayPort5Entry 36 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort5LowLimitAction1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile1: Thermostat low limit action for controlling a relay sensor."
|
|
::= { sensorProbeTemperatureArrayPort5Entry 37 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort5NormalAction2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile2: Thermostat normal action for controlling a relay sensor."
|
|
::= { sensorProbeTemperatureArrayPort5Entry 38 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort5HighLimit2 OBJECT-TYPE
|
|
SYNTAX INTEGER (-40..167)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile2: When this sersor higher than thermostat high limit, it will take a high limit action."
|
|
::= { sensorProbeTemperatureArrayPort5Entry 39 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort5HighLimitAction2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile2: Thermostat high limit action for controlling a relay sensor."
|
|
::= { sensorProbeTemperatureArrayPort5Entry 40 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort5LowLimit2 OBJECT-TYPE
|
|
SYNTAX INTEGER (-40..167)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile2: When this sersor higher than thermostat low limit, it will take a normal limit action."
|
|
::= { sensorProbeTemperatureArrayPort5Entry 41 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort5LowLimitAction2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile2: Thermostat low limit action for controlling a relay sensor."
|
|
::= { sensorProbeTemperatureArrayPort5Entry 42 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort5EnableTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time to enable on Thermostat"
|
|
::= { sensorProbeTemperatureArrayPort5Entry 43 }
|
|
|
|
sensorProbeTemperatureArrayPort6 OBJECT IDENTIFIER ::= { sensorProbeTemperatureArraySensor 6 }
|
|
sensorProbeTemperatureArrayPort6Number OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of port on the TemperatureArray."
|
|
::= { sensorProbeTemperatureArrayPort6 1 }
|
|
|
|
sensorProbeTemperatureArrayPort6Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorProbeTemperatureArrayPort6Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the data for every Switch Sensor in the SensorArray. Each row in the table contains data for a different Switch Sensor."
|
|
::= { sensorProbeTemperatureArrayPort6 2 }
|
|
|
|
sensorProbeTemperatureArrayPort6Entry OBJECT-TYPE
|
|
SYNTAX SensorProbeTemperatureArrayPort6Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorProbeTemperatureArrayPort6 Table"
|
|
INDEX { sensorProbeTemperatureArrayPort6Index }
|
|
::= { sensorProbeTemperatureArrayPort6Table 1 }
|
|
|
|
SensorProbeTemperatureArrayPort6Entry ::= SEQUENCE {
|
|
sensorProbeTemperatureArrayPort6Index
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort6Description
|
|
DisplayString,
|
|
sensorProbeTemperatureArrayPort6Value
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort6Status
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort6Online
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort6GoOnline
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort6HighWarning
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort6HighCritical
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort6LowWarning
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort6LowCritical
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort6Rearm
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort6DegreeType
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort6DegreeRaw
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort6Offset
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort6URL
|
|
DisplayString,
|
|
sensorProbeTemperatureArrayPort6OpenURL
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort6DatacollectType
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort6ContTimeHighCritical
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort6ContTimeHighWarning
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort6ContTimeNormal
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort6ContTimeLowWarning
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort6ContTimeLowCritical
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort6ContTimeSensorError
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort6Calendar
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort6Index
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort6Description
|
|
DisplayString,
|
|
sensorProbeThermostatTemperatureArrayPort6Value
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort6Online
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort6GoOnline
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort6Mode
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort6RelayControlPort
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort6NormalAction1
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort6HighLimit1
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort6HighLimitAction1
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort6LowLimit1
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort6LowLimitAction1
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort6NormalAction2
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort6HighLimit2
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort6HighLimitAction2
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort6LowLimit2
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort6LowLimitAction2
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort6EnableTime
|
|
DisplayString
|
|
}
|
|
|
|
sensorProbeTemperatureArrayPort6Index OBJECT-TYPE
|
|
SYNTAX INTEGER (0..7)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value for each sensor TemperatureArray port."
|
|
::= { sensorProbeTemperatureArrayPort6Entry 1 }
|
|
|
|
sensorProbeTemperatureArrayPort6Description OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor TemperatureArray"
|
|
::= { sensorProbeTemperatureArrayPort6Entry 2 }
|
|
|
|
sensorProbeTemperatureArrayPort6Value OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value in this sensor"
|
|
::= { sensorProbeTemperatureArrayPort6Entry 3 }
|
|
|
|
sensorProbeTemperatureArrayPort6Status OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highWarning(3),
|
|
highCritical(4),
|
|
lowWarning(5),
|
|
lowCritical(6),
|
|
sensorError(7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor"
|
|
::= { sensorProbeTemperatureArrayPort6Entry 4 }
|
|
|
|
sensorProbeTemperatureArrayPort6Online OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
offline(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If this Sensor is currently online"
|
|
::= { sensorProbeTemperatureArrayPort6Entry 5 }
|
|
|
|
sensorProbeTemperatureArrayPort6GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To put online enter a 1, to take offline enter a 2"
|
|
::= { sensorProbeTemperatureArrayPort6Entry 6 }
|
|
|
|
sensorProbeTemperatureArrayPort6HighWarning OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How hot this sensor gets before it sends a warning"
|
|
::= { sensorProbeTemperatureArrayPort6Entry 7 }
|
|
|
|
sensorProbeTemperatureArrayPort6HighCritical OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How hot this sensor gets before it sends a critical event"
|
|
::= { sensorProbeTemperatureArrayPort6Entry 8 }
|
|
|
|
sensorProbeTemperatureArrayPort6LowWarning OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How cold this sensor gets before it sends a warning"
|
|
::= { sensorProbeTemperatureArrayPort6Entry 9 }
|
|
|
|
sensorProbeTemperatureArrayPort6LowCritical OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How cold this sensor gets before it sends a critical event"
|
|
::= { sensorProbeTemperatureArrayPort6Entry 10 }
|
|
|
|
sensorProbeTemperatureArrayPort6Rearm OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of degrees to rearm the status. For example if status goes from normal to warning, the temp must go down spTempRearm degrees below warning before the status goes to normal"
|
|
::= { sensorProbeTemperatureArrayPort6Entry 11 }
|
|
|
|
sensorProbeTemperatureArrayPort6DegreeType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
fahr(0),
|
|
celsius(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The degrees are in fahrenheit(0) or in celsius(1)"
|
|
::= { sensorProbeTemperatureArrayPort6Entry 12 }
|
|
|
|
sensorProbeTemperatureArrayPort6DegreeRaw OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The raw degree data from the temperature sensor, slightly higher resolution"
|
|
::= { sensorProbeTemperatureArrayPort6Entry 14 }
|
|
|
|
sensorProbeTemperatureArrayPort6Offset OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset reading"
|
|
::= { sensorProbeTemperatureArrayPort6Entry 15 }
|
|
|
|
sensorProbeTemperatureArrayPort6URL OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor URL link."
|
|
::= { sensorProbeTemperatureArrayPort6Entry 16 }
|
|
|
|
sensorProbeTemperatureArrayPort6OpenURL OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cur-window(0),
|
|
new-window(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Open URL in this browser or open in a new window."
|
|
::= { sensorProbeTemperatureArrayPort6Entry 17 }
|
|
|
|
sensorProbeTemperatureArrayPort6DatacollectType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
average(1),
|
|
highest(2),
|
|
lowest(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Type of datacollect to collect."
|
|
::= { sensorProbeTemperatureArrayPort6Entry 18 }
|
|
|
|
sensorProbeTemperatureArrayPort6ContTimeHighCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in High Critical before accepting new Status."
|
|
::= { sensorProbeTemperatureArrayPort6Entry 19 }
|
|
|
|
sensorProbeTemperatureArrayPort6ContTimeHighWarning OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in High Warning before accepting new Status."
|
|
::= { sensorProbeTemperatureArrayPort6Entry 20 }
|
|
|
|
sensorProbeTemperatureArrayPort6ContTimeNormal OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Normal before accepting new Status."
|
|
::= { sensorProbeTemperatureArrayPort6Entry 21 }
|
|
|
|
sensorProbeTemperatureArrayPort6ContTimeLowWarning OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Low Warning before accepting new Status."
|
|
::= { sensorProbeTemperatureArrayPort6Entry 22 }
|
|
|
|
sensorProbeTemperatureArrayPort6ContTimeLowCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Low Critical before accepting new Status."
|
|
::= { sensorProbeTemperatureArrayPort6Entry 23 }
|
|
|
|
sensorProbeTemperatureArrayPort6ContTimeSensorError OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Sensor Error before accepting new Status."
|
|
::= { sensorProbeTemperatureArrayPort6Entry 24 }
|
|
|
|
sensorProbeTemperatureArrayPort6Calendar OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable the calendar filtering working hours of sensor."
|
|
::= { sensorProbeTemperatureArrayPort6Entry 25 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort6Index OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value for each sensor thermostat port."
|
|
::= { sensorProbeTemperatureArrayPort6Entry 26 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort6Description OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor thermostat"
|
|
::= { sensorProbeTemperatureArrayPort6Entry 27 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort6Value OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value in this sensor"
|
|
::= { sensorProbeTemperatureArrayPort6Entry 28 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort6Online OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
offline(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If this Sensor is currently online"
|
|
::= { sensorProbeTemperatureArrayPort6Entry 29 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort6GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To put online enter a 1, to take offline enter a 2"
|
|
::= { sensorProbeTemperatureArrayPort6Entry 30 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort6Mode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal(0),
|
|
time-bases(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To select the thermostat mode for working on time-bases(1) or normal(0)."
|
|
::= { sensorProbeTemperatureArrayPort6Entry 31 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort6RelayControlPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To select a relay port to be controled by this thermostat sensor."
|
|
::= { sensorProbeTemperatureArrayPort6Entry 32 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort6NormalAction1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile1: Thermostat normal action for controlling a relay sensor."
|
|
::= { sensorProbeTemperatureArrayPort6Entry 33 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort6HighLimit1 OBJECT-TYPE
|
|
SYNTAX INTEGER (-40..167)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile1: When this sersor higher than thermostat high limit, it will take a high limit action."
|
|
::= { sensorProbeTemperatureArrayPort6Entry 34 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort6HighLimitAction1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile1: Thermostat high limit action for controlling a relay sensor."
|
|
::= { sensorProbeTemperatureArrayPort6Entry 35 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort6LowLimit1 OBJECT-TYPE
|
|
SYNTAX INTEGER (-40..167)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile1: When this sersor higher than thermostat low limit, it will take a normal limit action."
|
|
::= { sensorProbeTemperatureArrayPort6Entry 36 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort6LowLimitAction1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile1: Thermostat low limit action for controlling a relay sensor."
|
|
::= { sensorProbeTemperatureArrayPort6Entry 37 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort6NormalAction2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile2: Thermostat normal action for controlling a relay sensor."
|
|
::= { sensorProbeTemperatureArrayPort6Entry 38 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort6HighLimit2 OBJECT-TYPE
|
|
SYNTAX INTEGER (-40..167)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile2: When this sersor higher than thermostat high limit, it will take a high limit action."
|
|
::= { sensorProbeTemperatureArrayPort6Entry 39 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort6HighLimitAction2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile2: Thermostat high limit action for controlling a relay sensor."
|
|
::= { sensorProbeTemperatureArrayPort6Entry 40 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort6LowLimit2 OBJECT-TYPE
|
|
SYNTAX INTEGER (-40..167)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile2: When this sersor higher than thermostat low limit, it will take a normal limit action."
|
|
::= { sensorProbeTemperatureArrayPort6Entry 41 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort6LowLimitAction2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile2: Thermostat low limit action for controlling a relay sensor."
|
|
::= { sensorProbeTemperatureArrayPort6Entry 42 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort6EnableTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time to enable on Thermostat"
|
|
::= { sensorProbeTemperatureArrayPort6Entry 43 }
|
|
|
|
sensorProbeTemperatureArrayPort7 OBJECT IDENTIFIER ::= { sensorProbeTemperatureArraySensor 7 }
|
|
sensorProbeTemperatureArrayPort7Number OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of port on the TemperatureArray."
|
|
::= { sensorProbeTemperatureArrayPort7 1 }
|
|
|
|
sensorProbeTemperatureArrayPort7Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorProbeTemperatureArrayPort7Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the data for every Switch Sensor in the SensorArray. Each row in the table contains data for a different Switch Sensor."
|
|
::= { sensorProbeTemperatureArrayPort7 2 }
|
|
|
|
sensorProbeTemperatureArrayPort7Entry OBJECT-TYPE
|
|
SYNTAX SensorProbeTemperatureArrayPort7Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorProbeTemperatureArrayPort7 Table"
|
|
INDEX { sensorProbeTemperatureArrayPort7Index }
|
|
::= { sensorProbeTemperatureArrayPort7Table 1 }
|
|
|
|
SensorProbeTemperatureArrayPort7Entry ::= SEQUENCE {
|
|
sensorProbeTemperatureArrayPort7Index
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort7Description
|
|
DisplayString,
|
|
sensorProbeTemperatureArrayPort7Value
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort7Status
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort7Online
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort7GoOnline
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort7HighWarning
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort7HighCritical
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort7LowWarning
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort7LowCritical
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort7Rearm
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort7DegreeType
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort7DegreeRaw
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort7Offset
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort7URL
|
|
DisplayString,
|
|
sensorProbeTemperatureArrayPort7OpenURL
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort7DatacollectType
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort7ContTimeHighCritical
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort7ContTimeHighWarning
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort7ContTimeNormal
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort7ContTimeLowWarning
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort7ContTimeLowCritical
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort7ContTimeSensorError
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort7Calendar
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort7Index
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort7Description
|
|
DisplayString,
|
|
sensorProbeThermostatTemperatureArrayPort7Value
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort7Online
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort7GoOnline
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort7Mode
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort7RelayControlPort
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort7NormalAction1
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort7HighLimit1
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort7HighLimitAction1
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort7LowLimit1
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort7LowLimitAction1
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort7NormalAction2
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort7HighLimit2
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort7HighLimitAction2
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort7LowLimit2
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort7LowLimitAction2
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort7EnableTime
|
|
DisplayString
|
|
}
|
|
|
|
sensorProbeTemperatureArrayPort7Index OBJECT-TYPE
|
|
SYNTAX INTEGER (0..7)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value for each sensor TemperatureArray port."
|
|
::= { sensorProbeTemperatureArrayPort7Entry 1 }
|
|
|
|
sensorProbeTemperatureArrayPort7Description OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor TemperatureArray"
|
|
::= { sensorProbeTemperatureArrayPort7Entry 2 }
|
|
|
|
sensorProbeTemperatureArrayPort7Value OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value in this sensor"
|
|
::= { sensorProbeTemperatureArrayPort7Entry 3 }
|
|
|
|
sensorProbeTemperatureArrayPort7Status OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highWarning(3),
|
|
highCritical(4),
|
|
lowWarning(5),
|
|
lowCritical(6),
|
|
sensorError(7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor"
|
|
::= { sensorProbeTemperatureArrayPort7Entry 4 }
|
|
|
|
sensorProbeTemperatureArrayPort7Online OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
offline(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If this Sensor is currently online"
|
|
::= { sensorProbeTemperatureArrayPort7Entry 5 }
|
|
|
|
sensorProbeTemperatureArrayPort7GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To put online enter a 1, to take offline enter a 2"
|
|
::= { sensorProbeTemperatureArrayPort7Entry 6 }
|
|
|
|
sensorProbeTemperatureArrayPort7HighWarning OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How hot this sensor gets before it sends a warning"
|
|
::= { sensorProbeTemperatureArrayPort7Entry 7 }
|
|
|
|
sensorProbeTemperatureArrayPort7HighCritical OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How hot this sensor gets before it sends a critical event"
|
|
::= { sensorProbeTemperatureArrayPort7Entry 8 }
|
|
|
|
sensorProbeTemperatureArrayPort7LowWarning OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How cold this sensor gets before it sends a warning"
|
|
::= { sensorProbeTemperatureArrayPort7Entry 9 }
|
|
|
|
sensorProbeTemperatureArrayPort7LowCritical OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How cold this sensor gets before it sends a critical event"
|
|
::= { sensorProbeTemperatureArrayPort7Entry 10 }
|
|
|
|
sensorProbeTemperatureArrayPort7Rearm OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of degrees to rearm the status. For example if status goes from normal to warning, the temp must go down spTempRearm degrees below warning before the status goes to normal"
|
|
::= { sensorProbeTemperatureArrayPort7Entry 11 }
|
|
|
|
sensorProbeTemperatureArrayPort7DegreeType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
fahr(0),
|
|
celsius(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The degrees are in fahrenheit(0) or in celsius(1)"
|
|
::= { sensorProbeTemperatureArrayPort7Entry 12 }
|
|
|
|
sensorProbeTemperatureArrayPort7DegreeRaw OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The raw degree data from the temperature sensor, slightly higher resolution"
|
|
::= { sensorProbeTemperatureArrayPort7Entry 14 }
|
|
|
|
sensorProbeTemperatureArrayPort7Offset OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset reading"
|
|
::= { sensorProbeTemperatureArrayPort7Entry 15 }
|
|
|
|
sensorProbeTemperatureArrayPort7URL OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor URL link."
|
|
::= { sensorProbeTemperatureArrayPort7Entry 16 }
|
|
|
|
sensorProbeTemperatureArrayPort7OpenURL OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cur-window(0),
|
|
new-window(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Open URL in this browser or open in a new window."
|
|
::= { sensorProbeTemperatureArrayPort7Entry 17 }
|
|
|
|
sensorProbeTemperatureArrayPort7DatacollectType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
average(1),
|
|
highest(2),
|
|
lowest(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Type of datacollect to collect."
|
|
::= { sensorProbeTemperatureArrayPort7Entry 18 }
|
|
|
|
sensorProbeTemperatureArrayPort7ContTimeHighCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in High Critical before accepting new Status."
|
|
::= { sensorProbeTemperatureArrayPort7Entry 19 }
|
|
|
|
sensorProbeTemperatureArrayPort7ContTimeHighWarning OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in High Warning before accepting new Status."
|
|
::= { sensorProbeTemperatureArrayPort7Entry 20 }
|
|
|
|
sensorProbeTemperatureArrayPort7ContTimeNormal OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Normal before accepting new Status."
|
|
::= { sensorProbeTemperatureArrayPort7Entry 21 }
|
|
|
|
sensorProbeTemperatureArrayPort7ContTimeLowWarning OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Low Warning before accepting new Status."
|
|
::= { sensorProbeTemperatureArrayPort7Entry 22 }
|
|
|
|
sensorProbeTemperatureArrayPort7ContTimeLowCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Low Critical before accepting new Status."
|
|
::= { sensorProbeTemperatureArrayPort7Entry 23 }
|
|
|
|
sensorProbeTemperatureArrayPort7ContTimeSensorError OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Sensor Error before accepting new Status."
|
|
::= { sensorProbeTemperatureArrayPort7Entry 24 }
|
|
|
|
sensorProbeTemperatureArrayPort7Calendar OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable the calendar filtering working hours of sensor."
|
|
::= { sensorProbeTemperatureArrayPort7Entry 25 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort7Index OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value for each sensor thermostat port."
|
|
::= { sensorProbeTemperatureArrayPort7Entry 26 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort7Description OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor thermostat"
|
|
::= { sensorProbeTemperatureArrayPort7Entry 27 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort7Value OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value in this sensor"
|
|
::= { sensorProbeTemperatureArrayPort7Entry 28 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort7Online OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
offline(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If this Sensor is currently online"
|
|
::= { sensorProbeTemperatureArrayPort7Entry 29 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort7GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To put online enter a 1, to take offline enter a 2"
|
|
::= { sensorProbeTemperatureArrayPort7Entry 30 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort7Mode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal(0),
|
|
time-bases(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To select the thermostat mode for working on time-bases(1) or normal(0)."
|
|
::= { sensorProbeTemperatureArrayPort7Entry 31 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort7RelayControlPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To select a relay port to be controled by this thermostat sensor."
|
|
::= { sensorProbeTemperatureArrayPort7Entry 32 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort7NormalAction1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile1: Thermostat normal action for controlling a relay sensor."
|
|
::= { sensorProbeTemperatureArrayPort7Entry 33 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort7HighLimit1 OBJECT-TYPE
|
|
SYNTAX INTEGER (-40..167)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile1: When this sersor higher than thermostat high limit, it will take a high limit action."
|
|
::= { sensorProbeTemperatureArrayPort7Entry 34 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort7HighLimitAction1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile1: Thermostat high limit action for controlling a relay sensor."
|
|
::= { sensorProbeTemperatureArrayPort7Entry 35 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort7LowLimit1 OBJECT-TYPE
|
|
SYNTAX INTEGER (-40..167)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile1: When this sersor higher than thermostat low limit, it will take a normal limit action."
|
|
::= { sensorProbeTemperatureArrayPort7Entry 36 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort7LowLimitAction1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile1: Thermostat low limit action for controlling a relay sensor."
|
|
::= { sensorProbeTemperatureArrayPort7Entry 37 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort7NormalAction2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile2: Thermostat normal action for controlling a relay sensor."
|
|
::= { sensorProbeTemperatureArrayPort7Entry 38 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort7HighLimit2 OBJECT-TYPE
|
|
SYNTAX INTEGER (-40..167)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile2: When this sersor higher than thermostat high limit, it will take a high limit action."
|
|
::= { sensorProbeTemperatureArrayPort7Entry 39 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort7HighLimitAction2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile2: Thermostat high limit action for controlling a relay sensor."
|
|
::= { sensorProbeTemperatureArrayPort7Entry 40 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort7LowLimit2 OBJECT-TYPE
|
|
SYNTAX INTEGER (-40..167)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile2: When this sersor higher than thermostat low limit, it will take a normal limit action."
|
|
::= { sensorProbeTemperatureArrayPort7Entry 41 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort7LowLimitAction2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile2: Thermostat low limit action for controlling a relay sensor."
|
|
::= { sensorProbeTemperatureArrayPort7Entry 42 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort7EnableTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time to enable on Thermostat"
|
|
::= { sensorProbeTemperatureArrayPort7Entry 43 }
|
|
|
|
sensorProbeTemperatureArrayPort8 OBJECT IDENTIFIER ::= { sensorProbeTemperatureArraySensor 8 }
|
|
sensorProbeTemperatureArrayPort8Number OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of port on the TemperatureArray."
|
|
::= { sensorProbeTemperatureArrayPort8 1 }
|
|
|
|
sensorProbeTemperatureArrayPort8Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorProbeTemperatureArrayPort8Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the data for every Switch Sensor in the SensorArray. Each row in the table contains data for a different Switch Sensor."
|
|
::= { sensorProbeTemperatureArrayPort8 2 }
|
|
|
|
sensorProbeTemperatureArrayPort8Entry OBJECT-TYPE
|
|
SYNTAX SensorProbeTemperatureArrayPort8Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorProbeTemperatureArrayPort8 Table"
|
|
INDEX { sensorProbeTemperatureArrayPort8Index }
|
|
::= { sensorProbeTemperatureArrayPort8Table 1 }
|
|
|
|
SensorProbeTemperatureArrayPort8Entry ::= SEQUENCE {
|
|
sensorProbeTemperatureArrayPort8Index
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort8Description
|
|
DisplayString,
|
|
sensorProbeTemperatureArrayPort8Value
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort8Status
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort8Online
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort8GoOnline
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort8HighWarning
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort8HighCritical
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort8LowWarning
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort8LowCritical
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort8Rearm
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort8DegreeType
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort8DegreeRaw
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort8Offset
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort8URL
|
|
DisplayString,
|
|
sensorProbeTemperatureArrayPort8OpenURL
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort8DatacollectType
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort8ContTimeHighCritical
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort8ContTimeHighWarning
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort8ContTimeNormal
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort8ContTimeLowWarning
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort8ContTimeLowCritical
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort8ContTimeSensorError
|
|
INTEGER,
|
|
sensorProbeTemperatureArrayPort8Calendar
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort8Index
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort8Description
|
|
DisplayString,
|
|
sensorProbeThermostatTemperatureArrayPort8Value
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort8Online
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort8GoOnline
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort8Mode
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort8RelayControlPort
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort8NormalAction1
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort8HighLimit1
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort8HighLimitAction1
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort8LowLimit1
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort8LowLimitAction1
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort8NormalAction2
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort8HighLimit2
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort8HighLimitAction2
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort8LowLimit2
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort8LowLimitAction2
|
|
INTEGER,
|
|
sensorProbeThermostatTemperatureArrayPort8EnableTime
|
|
DisplayString
|
|
}
|
|
|
|
sensorProbeTemperatureArrayPort8Index OBJECT-TYPE
|
|
SYNTAX INTEGER (0..7)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value for each sensor TemperatureArray port."
|
|
::= { sensorProbeTemperatureArrayPort8Entry 1 }
|
|
|
|
sensorProbeTemperatureArrayPort8Description OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor TemperatureArray"
|
|
::= { sensorProbeTemperatureArrayPort8Entry 2 }
|
|
|
|
sensorProbeTemperatureArrayPort8Value OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value in this sensor"
|
|
::= { sensorProbeTemperatureArrayPort8Entry 3 }
|
|
|
|
sensorProbeTemperatureArrayPort8Status OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highWarning(3),
|
|
highCritical(4),
|
|
lowWarning(5),
|
|
lowCritical(6),
|
|
sensorError(7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor"
|
|
::= { sensorProbeTemperatureArrayPort8Entry 4 }
|
|
|
|
sensorProbeTemperatureArrayPort8Online OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
offline(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If this Sensor is currently online"
|
|
::= { sensorProbeTemperatureArrayPort8Entry 5 }
|
|
|
|
sensorProbeTemperatureArrayPort8GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To put online enter a 1, to take offline enter a 2"
|
|
::= { sensorProbeTemperatureArrayPort8Entry 6 }
|
|
|
|
sensorProbeTemperatureArrayPort8HighWarning OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How hot this sensor gets before it sends a warning"
|
|
::= { sensorProbeTemperatureArrayPort8Entry 7 }
|
|
|
|
sensorProbeTemperatureArrayPort8HighCritical OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How hot this sensor gets before it sends a critical event"
|
|
::= { sensorProbeTemperatureArrayPort8Entry 8 }
|
|
|
|
sensorProbeTemperatureArrayPort8LowWarning OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How cold this sensor gets before it sends a warning"
|
|
::= { sensorProbeTemperatureArrayPort8Entry 9 }
|
|
|
|
sensorProbeTemperatureArrayPort8LowCritical OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How cold this sensor gets before it sends a critical event"
|
|
::= { sensorProbeTemperatureArrayPort8Entry 10 }
|
|
|
|
sensorProbeTemperatureArrayPort8Rearm OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of degrees to rearm the status. For example if status goes from normal to warning, the temp must go down spTempRearm degrees below warning before the status goes to normal"
|
|
::= { sensorProbeTemperatureArrayPort8Entry 11 }
|
|
|
|
sensorProbeTemperatureArrayPort8DegreeType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
fahr(0),
|
|
celsius(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The degrees are in fahrenheit(0) or in celsius(1)"
|
|
::= { sensorProbeTemperatureArrayPort8Entry 12 }
|
|
|
|
sensorProbeTemperatureArrayPort8DegreeRaw OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The raw degree data from the temperature sensor, slightly higher resolution"
|
|
::= { sensorProbeTemperatureArrayPort8Entry 14 }
|
|
|
|
sensorProbeTemperatureArrayPort8Offset OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset reading"
|
|
::= { sensorProbeTemperatureArrayPort8Entry 15 }
|
|
|
|
sensorProbeTemperatureArrayPort8URL OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor URL link."
|
|
::= { sensorProbeTemperatureArrayPort8Entry 16 }
|
|
|
|
sensorProbeTemperatureArrayPort8OpenURL OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cur-window(0),
|
|
new-window(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Open URL in this browser or open in a new window."
|
|
::= { sensorProbeTemperatureArrayPort8Entry 17 }
|
|
|
|
sensorProbeTemperatureArrayPort8DatacollectType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
average(1),
|
|
highest(2),
|
|
lowest(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Type of datacollect to collect."
|
|
::= { sensorProbeTemperatureArrayPort8Entry 18 }
|
|
|
|
sensorProbeTemperatureArrayPort8ContTimeHighCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in High Critical before accepting new Status."
|
|
::= { sensorProbeTemperatureArrayPort8Entry 19 }
|
|
|
|
sensorProbeTemperatureArrayPort8ContTimeHighWarning OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in High Warning before accepting new Status."
|
|
::= { sensorProbeTemperatureArrayPort8Entry 20 }
|
|
|
|
sensorProbeTemperatureArrayPort8ContTimeNormal OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Normal before accepting new Status."
|
|
::= { sensorProbeTemperatureArrayPort8Entry 21 }
|
|
|
|
sensorProbeTemperatureArrayPort8ContTimeLowWarning OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Low Warning before accepting new Status."
|
|
::= { sensorProbeTemperatureArrayPort8Entry 22 }
|
|
|
|
sensorProbeTemperatureArrayPort8ContTimeLowCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Low Critical before accepting new Status."
|
|
::= { sensorProbeTemperatureArrayPort8Entry 23 }
|
|
|
|
sensorProbeTemperatureArrayPort8ContTimeSensorError OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Sensor Error before accepting new Status."
|
|
::= { sensorProbeTemperatureArrayPort8Entry 24 }
|
|
|
|
sensorProbeTemperatureArrayPort8Calendar OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable the calendar filtering working hours of sensor."
|
|
::= { sensorProbeTemperatureArrayPort8Entry 25 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort8Index OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value for each sensor thermostat port."
|
|
::= { sensorProbeTemperatureArrayPort8Entry 26 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort8Description OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor thermostat"
|
|
::= { sensorProbeTemperatureArrayPort8Entry 27 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort8Value OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value in this sensor"
|
|
::= { sensorProbeTemperatureArrayPort8Entry 28 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort8Online OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
offline(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If this Sensor is currently online"
|
|
::= { sensorProbeTemperatureArrayPort8Entry 29 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort8GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To put online enter a 1, to take offline enter a 2"
|
|
::= { sensorProbeTemperatureArrayPort8Entry 30 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort8Mode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal(0),
|
|
time-bases(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To select the thermostat mode for working on time-bases(1) or normal(0)."
|
|
::= { sensorProbeTemperatureArrayPort8Entry 31 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort8RelayControlPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To select a relay port to be controled by this thermostat sensor."
|
|
::= { sensorProbeTemperatureArrayPort8Entry 32 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort8NormalAction1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile1: Thermostat normal action for controlling a relay sensor."
|
|
::= { sensorProbeTemperatureArrayPort8Entry 33 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort8HighLimit1 OBJECT-TYPE
|
|
SYNTAX INTEGER (-40..167)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile1: When this sersor higher than thermostat high limit, it will take a high limit action."
|
|
::= { sensorProbeTemperatureArrayPort8Entry 34 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort8HighLimitAction1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile1: Thermostat high limit action for controlling a relay sensor."
|
|
::= { sensorProbeTemperatureArrayPort8Entry 35 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort8LowLimit1 OBJECT-TYPE
|
|
SYNTAX INTEGER (-40..167)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile1: When this sersor higher than thermostat low limit, it will take a normal limit action."
|
|
::= { sensorProbeTemperatureArrayPort8Entry 36 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort8LowLimitAction1 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile1: Thermostat low limit action for controlling a relay sensor."
|
|
::= { sensorProbeTemperatureArrayPort8Entry 37 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort8NormalAction2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile2: Thermostat normal action for controlling a relay sensor."
|
|
::= { sensorProbeTemperatureArrayPort8Entry 38 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort8HighLimit2 OBJECT-TYPE
|
|
SYNTAX INTEGER (-40..167)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile2: When this sersor higher than thermostat high limit, it will take a high limit action."
|
|
::= { sensorProbeTemperatureArrayPort8Entry 39 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort8HighLimitAction2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile2: Thermostat high limit action for controlling a relay sensor."
|
|
::= { sensorProbeTemperatureArrayPort8Entry 40 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort8LowLimit2 OBJECT-TYPE
|
|
SYNTAX INTEGER (-40..167)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile2: When this sersor higher than thermostat low limit, it will take a normal limit action."
|
|
::= { sensorProbeTemperatureArrayPort8Entry 41 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort8LowLimitAction2 OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-on(0),
|
|
turn-off(1),
|
|
no-change(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Profile2: Thermostat low limit action for controlling a relay sensor."
|
|
::= { sensorProbeTemperatureArrayPort8Entry 42 }
|
|
|
|
sensorProbeThermostatTemperatureArrayPort8EnableTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time to enable on Thermostat"
|
|
::= { sensorProbeTemperatureArrayPort8Entry 43 }
|
|
|
|
sensorProbeNoCameraSensor OBJECT IDENTIFIER ::= { sensorProbeOtherSensor 34 }
|
|
|
|
sensorProbeNoCameraSensorNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of no camera sensor port."
|
|
::= { sensorProbeNoCameraSensor 1 }
|
|
|
|
sensorProbeNoCameraSensorTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorProbeNoCameraSensorEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the data for every no camera Sensor. Each row in the table contains data for a different NoCamera Sensor."
|
|
::= { sensorProbeNoCameraSensor 2 }
|
|
|
|
sensorProbeNoCameraSensorEntry OBJECT-TYPE
|
|
SYNTAX SensorProbeNoCameraSensorEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorProbeNoCameraSensorEntry Table"
|
|
INDEX { sensorProbeNoCameraSensorIndex }
|
|
::= { sensorProbeNoCameraSensorTable 1 }
|
|
|
|
SensorProbeNoCameraSensorEntry ::= SEQUENCE {
|
|
sensorProbeNoCameraSensorIndex
|
|
INTEGER,
|
|
sensorProbeNoCameraDescription
|
|
DisplayString,
|
|
sensorProbeNoCameraStatus
|
|
INTEGER,
|
|
sensorProbeNoCameraOnline
|
|
INTEGER,
|
|
sensorProbeNoCameraGoOnline
|
|
INTEGER,
|
|
sensorProbeNoCameraContTimeHighCritical
|
|
INTEGER,
|
|
sensorProbeNoCameraContTimeNormal
|
|
INTEGER,
|
|
sensorProbeNoCameraCalendar
|
|
INTEGER
|
|
}
|
|
|
|
sensorProbeNoCameraSensorIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..3)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value for each no camera sensor port."
|
|
::= { sensorProbeNoCameraSensorEntry 1 }
|
|
|
|
sensorProbeNoCameraDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor"
|
|
::= { sensorProbeNoCameraSensorEntry 2 }
|
|
|
|
sensorProbeNoCameraStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highCritical(4),
|
|
lowCritical(6),
|
|
sensorError(7),
|
|
relayOn(8),
|
|
relayOff(9)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor."
|
|
::= { sensorProbeNoCameraSensorEntry 4 }
|
|
|
|
sensorProbeNoCameraOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
offline(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If this Sensor is currently online"
|
|
::= { sensorProbeNoCameraSensorEntry 5 }
|
|
|
|
sensorProbeNoCameraGoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To put online enter a 1, to take offline enter a 2"
|
|
::= { sensorProbeNoCameraSensorEntry 6 }
|
|
|
|
sensorProbeNoCameraContTimeHighCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in High Critical before accepting new Status."
|
|
::= { sensorProbeNoCameraSensorEntry 7 }
|
|
|
|
sensorProbeNoCameraContTimeNormal OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Normal before accepting new Status."
|
|
::= { sensorProbeNoCameraSensorEntry 8 }
|
|
|
|
sensorProbeNoCameraCalendar OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable the calendar filtering working hours of sensor."
|
|
::= { sensorProbeNoCameraSensorEntry 9 }
|
|
|
|
sensorProbeSoftMotionSensor OBJECT IDENTIFIER ::= { sensorProbeOtherSensor 35 }
|
|
|
|
sensorProbeSoftMotionSensorNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of SoftMotionSensor port."
|
|
::= { sensorProbeSoftMotionSensor 1 }
|
|
|
|
sensorProbeSoftMotionSensorTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorProbeSoftMotionSensorEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the data for every SoftMotion Sensor. Each row in the table contains data for a different SoftMotion Sensor."
|
|
::= { sensorProbeSoftMotionSensor 2 }
|
|
|
|
sensorProbeSoftMotionSensorEntry OBJECT-TYPE
|
|
SYNTAX SensorProbeSoftMotionSensorEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorProbeSoftMotionSensorEntry Table"
|
|
INDEX { sensorProbeSoftMotionSensorIndex }
|
|
::= { sensorProbeSoftMotionSensorTable 1 }
|
|
|
|
SensorProbeSoftMotionSensorEntry ::= SEQUENCE {
|
|
sensorProbeSoftMotionSensorIndex
|
|
INTEGER,
|
|
sensorProbeSoftMotionDescription
|
|
DisplayString,
|
|
sensorProbeSoftMotionStatus
|
|
INTEGER,
|
|
sensorProbeSoftMotionOnline
|
|
INTEGER,
|
|
sensorProbeSoftMotionGoOnline
|
|
INTEGER,
|
|
sensorProbeSoftMotionPercentSensitivity
|
|
INTEGER,
|
|
sensorProbeSoftMotionURL
|
|
DisplayString,
|
|
sensorProbeSoftMotionOpenURL
|
|
INTEGER,
|
|
sensorProbeSoftMotionContTimeHighCritical
|
|
INTEGER,
|
|
sensorProbeSoftMotionContTimeNormal
|
|
INTEGER,
|
|
sensorProbeSoftMotionCalendar
|
|
INTEGER,
|
|
sensorProbeSoftMotionMask
|
|
INTEGER
|
|
}
|
|
|
|
sensorProbeSoftMotionSensorIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..3)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value for each soft motion sensor port."
|
|
::= { sensorProbeSoftMotionSensorEntry 1 }
|
|
|
|
sensorProbeSoftMotionDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor"
|
|
::= { sensorProbeSoftMotionSensorEntry 2 }
|
|
|
|
sensorProbeSoftMotionStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highCritical(4),
|
|
lowCritical(6),
|
|
sensorError(7),
|
|
relayOn(8),
|
|
relayOff(9)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor."
|
|
::= { sensorProbeSoftMotionSensorEntry 4 }
|
|
|
|
sensorProbeSoftMotionOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
offline(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If this Sensor is currently online"
|
|
::= { sensorProbeSoftMotionSensorEntry 5 }
|
|
|
|
sensorProbeSoftMotionGoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To put online enter a 1, to take offline enter a 2"
|
|
::= { sensorProbeSoftMotionSensorEntry 6 }
|
|
|
|
sensorProbeSoftMotionPercentSensitivity OBJECT-TYPE
|
|
SYNTAX INTEGER (0..100)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The percent of sensitivity uses for setting the sentisitivity of motion detector."
|
|
::= { sensorProbeSoftMotionSensorEntry 7 }
|
|
|
|
sensorProbeSoftMotionURL OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor URL link."
|
|
::= { sensorProbeSoftMotionSensorEntry 8 }
|
|
|
|
sensorProbeSoftMotionOpenURL OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cur-window(0),
|
|
new-window(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Open URL in this browser or open in a new window."
|
|
::= { sensorProbeSoftMotionSensorEntry 9 }
|
|
|
|
sensorProbeSoftMotionContTimeHighCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in High Critical before accepting new Status."
|
|
::= { sensorProbeSoftMotionSensorEntry 10 }
|
|
|
|
sensorProbeSoftMotionContTimeNormal OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Normal before accepting new Status."
|
|
::= { sensorProbeSoftMotionSensorEntry 11 }
|
|
|
|
sensorProbeSoftMotionCalendar OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable the calendar filtering working hours of sensor."
|
|
::= { sensorProbeSoftMotionSensorEntry 12 }
|
|
|
|
sensorProbeSoftMotionMask OBJECT-TYPE
|
|
SYNTAX INTEGER (0..33554431)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Mask of enable or disable of SoftMotion."
|
|
::= { sensorProbeSoftMotionSensorEntry 13 }
|
|
|
|
sensorProbeSoundDetectorSensor OBJECT IDENTIFIER ::= { sensorProbeOtherSensor 36 }
|
|
|
|
sensorProbeSoundDetectorSensorNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of SoundDetectorSensor port."
|
|
::= { sensorProbeSoundDetectorSensor 1 }
|
|
|
|
sensorProbeSoundDetectorSensorTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorProbeSoundDetectorSensorEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the data for every SoundDetectorSensor Sensor. Each row in the table contains data for a different SoundDetectorSensor Sensor."
|
|
::= { sensorProbeSoundDetectorSensor 2 }
|
|
|
|
sensorProbeSoundDetectorSensorEntry OBJECT-TYPE
|
|
SYNTAX SensorProbeSoundDetectorSensorEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorProbeSoundDetectorSensorEntry Table"
|
|
INDEX { sensorProbeSoundDetectorIndex }
|
|
::= { sensorProbeSoundDetectorSensorTable 1 }
|
|
|
|
SensorProbeSoundDetectorSensorEntry ::= SEQUENCE {
|
|
sensorProbeSoundDetectorIndex
|
|
INTEGER,
|
|
sensorProbeSoundDetectorDescription
|
|
DisplayString,
|
|
sensorProbeSoundDetectorValue
|
|
INTEGER,
|
|
sensorProbeSoundDetectorStatus
|
|
INTEGER,
|
|
sensorProbeSoundDetectorOnline
|
|
INTEGER,
|
|
sensorProbeSoundDetectorGoOnline
|
|
INTEGER,
|
|
sensorProbeSoundDetectorHighWarning
|
|
INTEGER,
|
|
sensorProbeSoundDetectorHighCritical
|
|
INTEGER,
|
|
sensorProbeSoundDetectorLowWarning
|
|
INTEGER,
|
|
sensorProbeSoundDetectorLowCritical
|
|
INTEGER,
|
|
sensorProbeSoundDetectorRearm
|
|
INTEGER,
|
|
sensorProbeSoundDetectorRecordingSource
|
|
INTEGER,
|
|
sensorProbeSoundDetectorMicBoost
|
|
INTEGER,
|
|
sensorProbeSoundDetectorMicSensitivity
|
|
INTEGER,
|
|
sensorProbeSoundDetectorPulseLength
|
|
INTEGER,
|
|
sensorProbeSoundDetectorURL
|
|
DisplayString,
|
|
sensorProbeSoundDetectorOpenURL
|
|
INTEGER,
|
|
sensorProbeSoundDetectorDatacollectType
|
|
INTEGER,
|
|
sensorProbeSoundDetectorContTimeHighCritical
|
|
INTEGER,
|
|
sensorProbeSoundDetectorContTimeHighWarning
|
|
INTEGER,
|
|
sensorProbeSoundDetectorContTimeNormal
|
|
INTEGER,
|
|
sensorProbeSoundDetectorContTimeLowWarning
|
|
INTEGER,
|
|
sensorProbeSoundDetectorContTimeLowCritical
|
|
INTEGER,
|
|
sensorProbeSoundDetectorContTimeSensorError
|
|
INTEGER,
|
|
sensorProbeSoundDetectorCalendar
|
|
INTEGER
|
|
}
|
|
|
|
sensorProbeSoundDetectorIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value for each sound detector sensor port."
|
|
::= { sensorProbeSoundDetectorSensorEntry 1 }
|
|
|
|
sensorProbeSoundDetectorDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor"
|
|
::= { sensorProbeSoundDetectorSensorEntry 2 }
|
|
|
|
sensorProbeSoundDetectorValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value in this sensor"
|
|
::= { sensorProbeSoundDetectorSensorEntry 3 }
|
|
|
|
sensorProbeSoundDetectorStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highWarning(3),
|
|
highCritical(4),
|
|
lowWarning(5),
|
|
lowCritical(6),
|
|
sensorError(7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor"
|
|
::= { sensorProbeSoundDetectorSensorEntry 4 }
|
|
|
|
sensorProbeSoundDetectorOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
offline(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If this Sensor is currently online"
|
|
::= { sensorProbeSoundDetectorSensorEntry 5 }
|
|
|
|
sensorProbeSoundDetectorGoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To put online enter a 1, to take offline enter a 2"
|
|
::= { sensorProbeSoundDetectorSensorEntry 6 }
|
|
|
|
sensorProbeSoundDetectorHighWarning OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How hot this sensor gets before it sends a warning"
|
|
::= { sensorProbeSoundDetectorSensorEntry 7 }
|
|
|
|
sensorProbeSoundDetectorHighCritical OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How hot this sensor gets before it sends a critical event"
|
|
::= { sensorProbeSoundDetectorSensorEntry 8 }
|
|
|
|
sensorProbeSoundDetectorLowWarning OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How cold this sensor gets before it sends a warning"
|
|
::= { sensorProbeSoundDetectorSensorEntry 9 }
|
|
|
|
sensorProbeSoundDetectorLowCritical OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How cold this sensor gets before it sends a critical event"
|
|
::= { sensorProbeSoundDetectorSensorEntry 10 }
|
|
|
|
sensorProbeSoundDetectorRearm OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of degrees to rearm the status. For example if status goes from normal to warning, the temp must go down Rearm degrees below warning before the status goes to normal"
|
|
::= { sensorProbeSoundDetectorSensorEntry 11 }
|
|
|
|
sensorProbeSoundDetectorRecordingSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
internal-mic(0),
|
|
line-in(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To select a recording source being in internal microphone(0) or in line-in(1)."
|
|
::= { sensorProbeSoundDetectorSensorEntry 12 }
|
|
|
|
sensorProbeSoundDetectorMicBoost OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable a microphone boost(+20 db)."
|
|
::= { sensorProbeSoundDetectorSensorEntry 13 }
|
|
|
|
sensorProbeSoundDetectorMicSensitivity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
i0(0),
|
|
i20(20),
|
|
i40(40),
|
|
i60(60),
|
|
i80(80),
|
|
i100(100)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The sensitivity of microphone to detect sound."
|
|
::= { sensorProbeSoundDetectorSensorEntry 14 }
|
|
|
|
sensorProbeSoundDetectorPulseLength OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for detecting before changing status."
|
|
::= { sensorProbeSoundDetectorSensorEntry 15 }
|
|
|
|
sensorProbeSoundDetectorURL OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor URL link."
|
|
::= { sensorProbeSoundDetectorSensorEntry 16 }
|
|
|
|
sensorProbeSoundDetectorOpenURL OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cur-window(0),
|
|
new-window(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Open URL in this browser or open in a new window."
|
|
::= { sensorProbeSoundDetectorSensorEntry 17 }
|
|
|
|
sensorProbeSoundDetectorDatacollectType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
average(1),
|
|
highest(2),
|
|
lowest(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Type of datacollect to collect."
|
|
::= { sensorProbeSoundDetectorSensorEntry 18 }
|
|
|
|
sensorProbeSoundDetectorContTimeHighCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in High Critical before accepting new Status."
|
|
::= { sensorProbeSoundDetectorSensorEntry 19 }
|
|
|
|
sensorProbeSoundDetectorContTimeHighWarning OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in High Warning before accepting new Status."
|
|
::= { sensorProbeSoundDetectorSensorEntry 20 }
|
|
|
|
sensorProbeSoundDetectorContTimeNormal OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Normal before accepting new Status."
|
|
::= { sensorProbeSoundDetectorSensorEntry 21 }
|
|
|
|
sensorProbeSoundDetectorContTimeLowWarning OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Low Warning before accepting new Status."
|
|
::= { sensorProbeSoundDetectorSensorEntry 22 }
|
|
|
|
sensorProbeSoundDetectorContTimeLowCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Low Critical before accepting new Status."
|
|
::= { sensorProbeSoundDetectorSensorEntry 23 }
|
|
|
|
sensorProbeSoundDetectorContTimeSensorError OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Sensor Error before accepting new Status."
|
|
::= { sensorProbeSoundDetectorSensorEntry 24 }
|
|
|
|
sensorProbeSoundDetectorCalendar OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or disable the calendar filtering working hours of sensor."
|
|
::= { sensorProbeSoundDetectorSensorEntry 25 }
|
|
|
|
sensorProbeDrycontactArraySensor OBJECT IDENTIFIER ::= { sensorProbeOtherSensor 37 }
|
|
|
|
sensorProbeDrycontactArrayPort1 OBJECT IDENTIFIER ::= { sensorProbeDrycontactArraySensor 1 }
|
|
sensorProbeDrycontactArrayPort1Number OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of port on the DrycontactArray."
|
|
::= { sensorProbeDrycontactArrayPort1 1 }
|
|
|
|
sensorProbeDrycontactArrayPort1Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorProbeDrycontactArrayPort1Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the data for every Drycontact Sensor in the SensorArray. Each row in the table contains data for a different Drycontact Sensor."
|
|
::= { sensorProbeDrycontactArrayPort1 2 }
|
|
|
|
sensorProbeDrycontactArrayPort1Entry OBJECT-TYPE
|
|
SYNTAX SensorProbeDrycontactArrayPort1Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorProbeDrycontactArrayPort1 Table"
|
|
INDEX { sensorProbeDrycontactArrayPort1Index }
|
|
::= { sensorProbeDrycontactArrayPort1Table 1 }
|
|
|
|
SensorProbeDrycontactArrayPort1Entry ::= SEQUENCE {
|
|
sensorProbeDrycontactArrayPort1Index
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort1Description
|
|
DisplayString,
|
|
sensorProbeDrycontactArrayPort1Status
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort1Online
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort1GoOnline
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort1NormalState
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort1Direction
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort1ContTimeCritical
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort1ContTimeNormal
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort1ManualOutputCycleTime
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort1ManualOutputAction
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort1OutputDescOn
|
|
DisplayString,
|
|
sensorProbeDrycontactArrayPort1OutputDescOff
|
|
DisplayString,
|
|
sensorProbeDrycontactArrayPort1URL
|
|
DisplayString,
|
|
sensorProbeDrycontactArrayPort1OpenURL
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort1ControlMode
|
|
INTEGER
|
|
}
|
|
|
|
sensorProbeDrycontactArrayPort1Index OBJECT-TYPE
|
|
SYNTAX INTEGER (0..7)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value for each sensor DrycontactArray port."
|
|
::= { sensorProbeDrycontactArrayPort1Entry 1 }
|
|
|
|
sensorProbeDrycontactArrayPort1Description OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor DrycontactArray"
|
|
::= { sensorProbeDrycontactArrayPort1Entry 2 }
|
|
|
|
sensorProbeDrycontactArrayPort1Status OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highCritical(4),
|
|
lowCritical(6),
|
|
sensorError(7),
|
|
relayOn(8),
|
|
relayOff(9)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor"
|
|
::= { sensorProbeDrycontactArrayPort1Entry 4 }
|
|
|
|
sensorProbeDrycontactArrayPort1Online OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
offline(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If this Sensor is currently online"
|
|
::= { sensorProbeDrycontactArrayPort1Entry 5 }
|
|
|
|
sensorProbeDrycontactArrayPort1GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To put online enter a 1, to take offline enter a 2"
|
|
::= { sensorProbeDrycontactArrayPort1Entry 6 }
|
|
|
|
sensorProbeDrycontactArrayPort1NormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
closed(0),
|
|
open(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The normal state of DrycontactArray"
|
|
::= { sensorProbeDrycontactArrayPort1Entry 7 }
|
|
|
|
sensorProbeDrycontactArrayPort1Direction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
input(0),
|
|
output(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To set a drycontact to input enter 0. To set a switch to output enter 1"
|
|
::= { sensorProbeDrycontactArrayPort1Entry 8 }
|
|
|
|
sensorProbeDrycontactArrayPort1ContTimeCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Critical before accepting new Status."
|
|
::= { sensorProbeDrycontactArrayPort1Entry 9 }
|
|
|
|
sensorProbeDrycontactArrayPort1ContTimeNormal OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Normal before accepting new Status."
|
|
::= { sensorProbeDrycontactArrayPort1Entry 10 }
|
|
|
|
sensorProbeDrycontactArrayPort1ManualOutputCycleTime OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drycontact output toggle period in seconds for Manual Cycle action."
|
|
::= { sensorProbeDrycontactArrayPort1Entry 24 }
|
|
|
|
sensorProbeDrycontactArrayPort1ManualOutputAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
allow-sensor-control(1),
|
|
turn-on(3),
|
|
turn-off(4),
|
|
cycle-Off-On-Off(7),
|
|
cycle-On-Off-On(8)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Control the drycontact output manualy"
|
|
::= { sensorProbeDrycontactArrayPort1Entry 25 }
|
|
|
|
sensorProbeDrycontactArrayPort1OutputDescOn OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of Drycontact output On"
|
|
::= { sensorProbeDrycontactArrayPort1Entry 26 }
|
|
|
|
sensorProbeDrycontactArrayPort1OutputDescOff OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of Drycontact output Off"
|
|
::= { sensorProbeDrycontactArrayPort1Entry 27 }
|
|
|
|
sensorProbeDrycontactArrayPort1URL OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sersor URL link."
|
|
::= { sensorProbeDrycontactArrayPort1Entry 28 }
|
|
|
|
sensorProbeDrycontactArrayPort1OpenURL OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cur-window(0),
|
|
new-window(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Open URL in this browser or open in a new window."
|
|
::= { sensorProbeDrycontactArrayPort1Entry 29 }
|
|
|
|
sensorProbeDrycontactArrayPort1ControlMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
manual-control(0),
|
|
notification-control(1),
|
|
time-control(2),
|
|
thermostat-control(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Control Mode used for selecting the mode to control a drycontact output."
|
|
::= { sensorProbeDrycontactArrayPort1Entry 30 }
|
|
|
|
sensorProbeDrycontactArrayPort2 OBJECT IDENTIFIER ::= { sensorProbeDrycontactArraySensor 2 }
|
|
sensorProbeDrycontactArrayPort2Number OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of port on the DrycontactArray."
|
|
::= { sensorProbeDrycontactArrayPort2 1 }
|
|
|
|
sensorProbeDrycontactArrayPort2Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorProbeDrycontactArrayPort2Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the data for every Drycontact Sensor in the SensorArray. Each row in the table contains data for a different Drycontact Sensor."
|
|
::= { sensorProbeDrycontactArrayPort2 2 }
|
|
|
|
sensorProbeDrycontactArrayPort2Entry OBJECT-TYPE
|
|
SYNTAX SensorProbeDrycontactArrayPort2Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorProbeDrycontactArrayPort2 Table"
|
|
INDEX { sensorProbeDrycontactArrayPort2Index }
|
|
::= { sensorProbeDrycontactArrayPort2Table 1 }
|
|
|
|
SensorProbeDrycontactArrayPort2Entry ::= SEQUENCE {
|
|
sensorProbeDrycontactArrayPort2Index
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort2Description
|
|
DisplayString,
|
|
sensorProbeDrycontactArrayPort2Status
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort2Online
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort2GoOnline
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort2NormalState
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort2Direction
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort2ContTimeCritical
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort2ContTimeNormal
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort2ManualOutputCycleTime
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort2ManualOutputAction
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort2OutputDescOn
|
|
DisplayString,
|
|
sensorProbeDrycontactArrayPort2OutputDescOff
|
|
DisplayString,
|
|
sensorProbeDrycontactArrayPort2URL
|
|
DisplayString,
|
|
sensorProbeDrycontactArrayPort2OpenURL
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort2ControlMode
|
|
INTEGER
|
|
}
|
|
|
|
sensorProbeDrycontactArrayPort2Index OBJECT-TYPE
|
|
SYNTAX INTEGER (0..7)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value for each sensor DrycontactArray port."
|
|
::= { sensorProbeDrycontactArrayPort2Entry 1 }
|
|
|
|
sensorProbeDrycontactArrayPort2Description OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor DrycontactArray"
|
|
::= { sensorProbeDrycontactArrayPort2Entry 2 }
|
|
|
|
sensorProbeDrycontactArrayPort2Status OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highCritical(4),
|
|
lowCritical(6),
|
|
sensorError(7),
|
|
relayOn(8),
|
|
relayOff(9)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor"
|
|
::= { sensorProbeDrycontactArrayPort2Entry 4 }
|
|
|
|
sensorProbeDrycontactArrayPort2Online OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
offline(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If this Sensor is currently online"
|
|
::= { sensorProbeDrycontactArrayPort2Entry 5 }
|
|
|
|
sensorProbeDrycontactArrayPort2GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To put online enter a 1, to take offline enter a 2"
|
|
::= { sensorProbeDrycontactArrayPort2Entry 6 }
|
|
|
|
sensorProbeDrycontactArrayPort2NormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
closed(0),
|
|
open(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The normal state of DrycontactArray"
|
|
::= { sensorProbeDrycontactArrayPort2Entry 7 }
|
|
|
|
sensorProbeDrycontactArrayPort2Direction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
input(0),
|
|
output(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To set a drycontact to input enter 0. To set a switch to output enter 1"
|
|
::= { sensorProbeDrycontactArrayPort2Entry 8 }
|
|
|
|
sensorProbeDrycontactArrayPort2ContTimeCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Critical before accepting new Status."
|
|
::= { sensorProbeDrycontactArrayPort2Entry 9 }
|
|
|
|
sensorProbeDrycontactArrayPort2ContTimeNormal OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Normal before accepting new Status."
|
|
::= { sensorProbeDrycontactArrayPort2Entry 10 }
|
|
|
|
sensorProbeDrycontactArrayPort2ManualOutputCycleTime OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drycontact toggle period in seconds for Manual Cycle action."
|
|
::= { sensorProbeDrycontactArrayPort2Entry 24 }
|
|
|
|
sensorProbeDrycontactArrayPort2ManualOutputAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
allow-sensor-control(1),
|
|
turn-on(3),
|
|
turn-off(4),
|
|
cycle-Off-On-Off(7),
|
|
cycle-On-Off-On(8)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Control the Drycontact output manualy"
|
|
::= { sensorProbeDrycontactArrayPort2Entry 25 }
|
|
|
|
sensorProbeDrycontactArrayPort2OutputDescOn OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of Drycontact output On"
|
|
::= { sensorProbeDrycontactArrayPort2Entry 26 }
|
|
|
|
sensorProbeDrycontactArrayPort2OutputDescOff OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of Drycontact output Off"
|
|
::= { sensorProbeDrycontactArrayPort2Entry 27 }
|
|
|
|
sensorProbeDrycontactArrayPort2URL OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor URL link"
|
|
::= { sensorProbeDrycontactArrayPort2Entry 28 }
|
|
|
|
sensorProbeDrycontactArrayPort2OpenURL OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cur-window(0),
|
|
new-window(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Open URL in this browser or open in a new window."
|
|
::= { sensorProbeDrycontactArrayPort2Entry 29 }
|
|
|
|
sensorProbeDrycontactArrayPort2ControlMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
manual-control(0),
|
|
notification-control(1),
|
|
time-control(2),
|
|
thermostat-control(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Control Mode used for selecting the mode to control a Drycontact output."
|
|
::= { sensorProbeDrycontactArrayPort2Entry 30 }
|
|
|
|
sensorProbeDrycontactArrayPort3 OBJECT IDENTIFIER ::= { sensorProbeDrycontactArraySensor 3 }
|
|
sensorProbeDrycontactArrayPort3Number OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of port on the DrycontactArray."
|
|
::= { sensorProbeDrycontactArrayPort3 1 }
|
|
|
|
sensorProbeDrycontactArrayPort3Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorProbeDrycontactArrayPort3Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the data for every Drycontact Sensor in the SensorArray. Each row in the table contains data for a different Drycontact Sensor."
|
|
::= { sensorProbeDrycontactArrayPort3 2 }
|
|
|
|
sensorProbeDrycontactArrayPort3Entry OBJECT-TYPE
|
|
SYNTAX SensorProbeDrycontactArrayPort3Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorProbeDrycontactArrayPort3 Table"
|
|
INDEX { sensorProbeDrycontactArrayPort3Index }
|
|
::= { sensorProbeDrycontactArrayPort3Table 1 }
|
|
|
|
SensorProbeDrycontactArrayPort3Entry ::= SEQUENCE {
|
|
sensorProbeDrycontactArrayPort3Index
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort3Description
|
|
DisplayString,
|
|
sensorProbeDrycontactArrayPort3Status
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort3Online
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort3GoOnline
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort3NormalState
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort3Direction
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort3ContTimeCritical
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort3ContTimeNormal
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort3ManualOutputCycleTime
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort3ManualOutputAction
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort3OutputDescOn
|
|
DisplayString,
|
|
sensorProbeDrycontactArrayPort3OutputDescOff
|
|
DisplayString,
|
|
sensorProbeDrycontactArrayPort3URL
|
|
DisplayString,
|
|
sensorProbeDrycontactArrayPort3OpenURL
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort3ControlMode
|
|
INTEGER
|
|
}
|
|
|
|
sensorProbeDrycontactArrayPort3Index OBJECT-TYPE
|
|
SYNTAX INTEGER (0..7)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value for each sensor DrycontactArray port."
|
|
::= { sensorProbeDrycontactArrayPort3Entry 1 }
|
|
|
|
sensorProbeDrycontactArrayPort3Description OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor DrycontactArray"
|
|
::= { sensorProbeDrycontactArrayPort3Entry 2 }
|
|
|
|
sensorProbeDrycontactArrayPort3Status OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highCritical(4),
|
|
lowCritical(6),
|
|
sensorError(7),
|
|
relayOn(8),
|
|
relayOff(9)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor"
|
|
::= { sensorProbeDrycontactArrayPort3Entry 4 }
|
|
|
|
sensorProbeDrycontactArrayPort3Online OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
offline(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If this Sensor is currently online"
|
|
::= { sensorProbeDrycontactArrayPort3Entry 5 }
|
|
|
|
sensorProbeDrycontactArrayPort3GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To put online enter a 1, to take offline enter a 2"
|
|
::= { sensorProbeDrycontactArrayPort3Entry 6 }
|
|
|
|
sensorProbeDrycontactArrayPort3NormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
closed(0),
|
|
open(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The normal state of DrycontactArray"
|
|
::= { sensorProbeDrycontactArrayPort3Entry 7 }
|
|
|
|
sensorProbeDrycontactArrayPort3Direction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
input(0),
|
|
output(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To set a drycontact to input enter 0. To set a switch to output enter 1"
|
|
::= { sensorProbeDrycontactArrayPort3Entry 8 }
|
|
|
|
sensorProbeDrycontactArrayPort3ContTimeCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Critical before accepting new Status."
|
|
::= { sensorProbeDrycontactArrayPort3Entry 9 }
|
|
|
|
sensorProbeDrycontactArrayPort3ContTimeNormal OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Normal before accepting new Status."
|
|
::= { sensorProbeDrycontactArrayPort3Entry 10 }
|
|
|
|
sensorProbeDrycontactArrayPort3ManualOutputCycleTime OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drycontact toggle period in seconds for Manual Cycle action."
|
|
::= { sensorProbeDrycontactArrayPort3Entry 24 }
|
|
|
|
sensorProbeDrycontactArrayPort3ManualOutputAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
allow-sensor-control(1),
|
|
turn-on(3),
|
|
turn-off(4),
|
|
cycle-Off-On-Off(7),
|
|
cycle-On-Off-On(8)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Control the Drycontact output manualy"
|
|
::= { sensorProbeDrycontactArrayPort3Entry 25 }
|
|
|
|
sensorProbeDrycontactArrayPort3OutputDescOn OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of Drycontact output On"
|
|
::= { sensorProbeDrycontactArrayPort3Entry 26 }
|
|
|
|
sensorProbeDrycontactArrayPort3OutputDescOff OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of Drycontact output Off"
|
|
::= { sensorProbeDrycontactArrayPort3Entry 27 }
|
|
|
|
sensorProbeDrycontactArrayPort3URL OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor URL link."
|
|
::= { sensorProbeDrycontactArrayPort3Entry 28 }
|
|
|
|
sensorProbeDrycontactArrayPort3OpenURL OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cur-window(0),
|
|
new-window(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Open URL in this browser or open in a new window."
|
|
::= { sensorProbeDrycontactArrayPort3Entry 29 }
|
|
|
|
sensorProbeDrycontactArrayPort3ControlMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
manual-control(0),
|
|
notification-control(1),
|
|
time-control(2),
|
|
thermostat-control(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Control Mode used for selecting the mode to control a Drycontact output."
|
|
::= { sensorProbeDrycontactArrayPort3Entry 30 }
|
|
|
|
sensorProbeDrycontactArrayPort4 OBJECT IDENTIFIER ::= { sensorProbeDrycontactArraySensor 4 }
|
|
sensorProbeDrycontactArrayPort4Number OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of port on the DrycontactArray."
|
|
::= { sensorProbeDrycontactArrayPort4 1 }
|
|
|
|
sensorProbeDrycontactArrayPort4Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorProbeDrycontactArrayPort4Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the data for every Drycontact Sensor in the SensorArray. Each row in the table contains data for a different Drycontact Sensor."
|
|
::= { sensorProbeDrycontactArrayPort4 2 }
|
|
|
|
sensorProbeDrycontactArrayPort4Entry OBJECT-TYPE
|
|
SYNTAX SensorProbeDrycontactArrayPort4Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorProbeDrycontactArrayPort4 Table"
|
|
INDEX { sensorProbeDrycontactArrayPort4Index }
|
|
::= { sensorProbeDrycontactArrayPort4Table 1 }
|
|
|
|
SensorProbeDrycontactArrayPort4Entry ::= SEQUENCE {
|
|
sensorProbeDrycontactArrayPort4Index
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort4Description
|
|
DisplayString,
|
|
sensorProbeDrycontactArrayPort4Status
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort4Online
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort4GoOnline
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort4NormalState
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort4Direction
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort4ContTimeCritical
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort4ContTimeNormal
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort4ManualOutputCycleTime
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort4ManualOutputAction
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort4OutputDescOn
|
|
DisplayString,
|
|
sensorProbeDrycontactArrayPort4OutputDescOff
|
|
DisplayString,
|
|
sensorProbeDrycontactArrayPort4URL
|
|
DisplayString,
|
|
sensorProbeDrycontactArrayPort4OpenURL
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort4ControlMode
|
|
INTEGER
|
|
}
|
|
|
|
sensorProbeDrycontactArrayPort4Index OBJECT-TYPE
|
|
SYNTAX INTEGER (0..7)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value for each sensor DrycontactArray port."
|
|
::= { sensorProbeDrycontactArrayPort4Entry 1 }
|
|
|
|
sensorProbeDrycontactArrayPort4Description OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor DrycontactArray"
|
|
::= { sensorProbeDrycontactArrayPort4Entry 2 }
|
|
|
|
sensorProbeDrycontactArrayPort4Status OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highCritical(4),
|
|
lowCritical(6),
|
|
sensorError(7),
|
|
relayOn(8),
|
|
relayOff(9)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor"
|
|
::= { sensorProbeDrycontactArrayPort4Entry 4 }
|
|
|
|
sensorProbeDrycontactArrayPort4Online OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
offline(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If this Sensor is currently online"
|
|
::= { sensorProbeDrycontactArrayPort4Entry 5 }
|
|
|
|
sensorProbeDrycontactArrayPort4GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To put online enter a 1, to take offline enter a 2"
|
|
::= { sensorProbeDrycontactArrayPort4Entry 6 }
|
|
|
|
sensorProbeDrycontactArrayPort4NormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
closed(0),
|
|
open(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The normal state of DrycontactArray"
|
|
::= { sensorProbeDrycontactArrayPort4Entry 7 }
|
|
|
|
sensorProbeDrycontactArrayPort4Direction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
input(0),
|
|
output(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To set a drycontact to input enter 0. To set a switch to output enter 1"
|
|
::= { sensorProbeDrycontactArrayPort4Entry 8 }
|
|
|
|
sensorProbeDrycontactArrayPort4ContTimeCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Critical before accepting new Status."
|
|
::= { sensorProbeDrycontactArrayPort4Entry 9 }
|
|
|
|
sensorProbeDrycontactArrayPort4ContTimeNormal OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Normal before accepting new Status."
|
|
::= { sensorProbeDrycontactArrayPort4Entry 10 }
|
|
|
|
sensorProbeDrycontactArrayPort4ManualOutputCycleTime OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drycontact toggle period in seconds for Manual Cycle action."
|
|
::= { sensorProbeDrycontactArrayPort4Entry 24 }
|
|
|
|
sensorProbeDrycontactArrayPort4ManualOutputAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
allow-sensor-control(1),
|
|
turn-on(3),
|
|
turn-off(4),
|
|
cycle-Off-On-Off(7),
|
|
cycle-On-Off-On(8)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Control the Drycontact output manualy"
|
|
::= { sensorProbeDrycontactArrayPort4Entry 25 }
|
|
|
|
sensorProbeDrycontactArrayPort4OutputDescOn OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of Drycontact output On"
|
|
::= { sensorProbeDrycontactArrayPort4Entry 26 }
|
|
|
|
sensorProbeDrycontactArrayPort4OutputDescOff OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of Drycontact output Off"
|
|
::= { sensorProbeDrycontactArrayPort4Entry 27 }
|
|
|
|
sensorProbeDrycontactArrayPort4URL OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor URL link."
|
|
::= { sensorProbeDrycontactArrayPort4Entry 28 }
|
|
|
|
sensorProbeDrycontactArrayPort4OpenURL OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cur-window(0),
|
|
new-window(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Open URL in this browser or open in a new window."
|
|
::= { sensorProbeDrycontactArrayPort4Entry 29 }
|
|
|
|
sensorProbeDrycontactArrayPort4ControlMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
manual-control(0),
|
|
notification-control(1),
|
|
time-control(2),
|
|
thermostat-control(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Control Mode used for selecting the mode to control a Drycontact output."
|
|
::= { sensorProbeDrycontactArrayPort4Entry 30 }
|
|
|
|
sensorProbeDrycontactArrayPort5 OBJECT IDENTIFIER ::= { sensorProbeDrycontactArraySensor 5 }
|
|
sensorProbeDrycontactArrayPort5Number OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of port on the DrycontactArray."
|
|
::= { sensorProbeDrycontactArrayPort5 1 }
|
|
|
|
sensorProbeDrycontactArrayPort5Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorProbeDrycontactArrayPort5Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the data for every Drycontact Sensor in the SensorArray. Each row in the table contains data for a different Drycontact Sensor."
|
|
::= { sensorProbeDrycontactArrayPort5 2 }
|
|
|
|
sensorProbeDrycontactArrayPort5Entry OBJECT-TYPE
|
|
SYNTAX SensorProbeDrycontactArrayPort5Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorProbeDrycontactArrayPort5 Table"
|
|
INDEX { sensorProbeDrycontactArrayPort5Index }
|
|
::= { sensorProbeDrycontactArrayPort5Table 1 }
|
|
|
|
SensorProbeDrycontactArrayPort5Entry ::= SEQUENCE {
|
|
sensorProbeDrycontactArrayPort5Index
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort5Description
|
|
DisplayString,
|
|
sensorProbeDrycontactArrayPort5Status
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort5Online
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort5GoOnline
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort5NormalState
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort5Direction
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort5ContTimeCritical
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort5ContTimeNormal
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort5ManualOutputCycleTime
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort5ManualOutputAction
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort5OutputDescOn
|
|
DisplayString,
|
|
sensorProbeDrycontactArrayPort5OutputDescOff
|
|
DisplayString,
|
|
sensorProbeDrycontactArrayPort5URL
|
|
DisplayString,
|
|
sensorProbeDrycontactArrayPort5OpenURL
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort5ControlMode
|
|
INTEGER
|
|
}
|
|
|
|
sensorProbeDrycontactArrayPort5Index OBJECT-TYPE
|
|
SYNTAX INTEGER (0..7)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value for each sensor DrycontactArray port."
|
|
::= { sensorProbeDrycontactArrayPort5Entry 1 }
|
|
|
|
sensorProbeDrycontactArrayPort5Description OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor DrycontactArray"
|
|
::= { sensorProbeDrycontactArrayPort5Entry 2 }
|
|
|
|
sensorProbeDrycontactArrayPort5Status OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highCritical(4),
|
|
lowCritical(6),
|
|
sensorError(7),
|
|
relayOn(8),
|
|
relayOff(9)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor"
|
|
::= { sensorProbeDrycontactArrayPort5Entry 4 }
|
|
|
|
sensorProbeDrycontactArrayPort5Online OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
offline(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If this Sensor is currently online"
|
|
::= { sensorProbeDrycontactArrayPort5Entry 5 }
|
|
|
|
sensorProbeDrycontactArrayPort5GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To put online enter a 1, to take offline enter a 2"
|
|
::= { sensorProbeDrycontactArrayPort5Entry 6 }
|
|
|
|
sensorProbeDrycontactArrayPort5NormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
closed(0),
|
|
open(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The normal state of DrycontactArray"
|
|
::= { sensorProbeDrycontactArrayPort5Entry 7 }
|
|
|
|
sensorProbeDrycontactArrayPort5Direction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
input(0),
|
|
output(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To set a drycontact to input enter 0. To set a switch to output enter 1"
|
|
::= { sensorProbeDrycontactArrayPort5Entry 8 }
|
|
|
|
sensorProbeDrycontactArrayPort5ContTimeCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Critical before accepting new Status."
|
|
::= { sensorProbeDrycontactArrayPort5Entry 9 }
|
|
|
|
sensorProbeDrycontactArrayPort5ContTimeNormal OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Normal before accepting new Status."
|
|
::= { sensorProbeDrycontactArrayPort5Entry 10 }
|
|
|
|
sensorProbeDrycontactArrayPort5ManualOutputCycleTime OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drycontact toggle period in seconds for Manual Cycle action."
|
|
::= { sensorProbeDrycontactArrayPort5Entry 24 }
|
|
|
|
sensorProbeDrycontactArrayPort5ManualOutputAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
allow-sensor-control(1),
|
|
turn-on(3),
|
|
turn-off(4),
|
|
cycle-Off-On-Off(7),
|
|
cycle-On-Off-On(8)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Control the Drycontact output manualy"
|
|
::= { sensorProbeDrycontactArrayPort5Entry 25 }
|
|
|
|
sensorProbeDrycontactArrayPort5OutputDescOn OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of Drycontact output On"
|
|
::= { sensorProbeDrycontactArrayPort5Entry 26 }
|
|
|
|
sensorProbeDrycontactArrayPort5OutputDescOff OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of Drycontact output Off"
|
|
::= { sensorProbeDrycontactArrayPort5Entry 27 }
|
|
|
|
sensorProbeDrycontactArrayPort5URL OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor URL link."
|
|
::= { sensorProbeDrycontactArrayPort5Entry 28 }
|
|
|
|
sensorProbeDrycontactArrayPort5OpenURL OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cur-window(0),
|
|
new-window(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Open URL in this browser or open in a new window."
|
|
::= { sensorProbeDrycontactArrayPort5Entry 29 }
|
|
|
|
sensorProbeDrycontactArrayPort5ControlMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
manual-control(0),
|
|
notification-control(1),
|
|
time-control(2),
|
|
thermostat-control(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Control Mode used for selecting the mode to control a Drycontact output."
|
|
::= { sensorProbeDrycontactArrayPort5Entry 30 }
|
|
|
|
sensorProbeDrycontactArrayPort6 OBJECT IDENTIFIER ::= { sensorProbeDrycontactArraySensor 6 }
|
|
sensorProbeDrycontactArrayPort6Number OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of port on the DrycontactArray."
|
|
::= { sensorProbeDrycontactArrayPort6 1 }
|
|
|
|
sensorProbeDrycontactArrayPort6Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorProbeDrycontactArrayPort6Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the data for every Drycontact Sensor in the SensorArray. Each row in the table contains data for a different Drycontact Sensor."
|
|
::= { sensorProbeDrycontactArrayPort6 2 }
|
|
|
|
sensorProbeDrycontactArrayPort6Entry OBJECT-TYPE
|
|
SYNTAX SensorProbeDrycontactArrayPort6Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorProbeDrycontactArrayPort6 Table"
|
|
INDEX { sensorProbeDrycontactArrayPort6Index }
|
|
::= { sensorProbeDrycontactArrayPort6Table 1 }
|
|
|
|
SensorProbeDrycontactArrayPort6Entry ::= SEQUENCE {
|
|
sensorProbeDrycontactArrayPort6Index
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort6Description
|
|
DisplayString,
|
|
sensorProbeDrycontactArrayPort6Status
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort6Online
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort6GoOnline
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort6NormalState
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort6Direction
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort6ContTimeCritical
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort6ContTimeNormal
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort6ManualOutputCycleTime
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort6ManualOutputAction
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort6OutputDescOn
|
|
DisplayString,
|
|
sensorProbeDrycontactArrayPort6OutputDescOff
|
|
DisplayString,
|
|
sensorProbeDrycontactArrayPort6URL
|
|
DisplayString,
|
|
sensorProbeDrycontactArrayPort6OpenURL
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort6ControlMode
|
|
INTEGER
|
|
}
|
|
|
|
sensorProbeDrycontactArrayPort6Index OBJECT-TYPE
|
|
SYNTAX INTEGER (0..7)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value for each sensor DrycontactArray port."
|
|
::= { sensorProbeDrycontactArrayPort6Entry 1 }
|
|
|
|
sensorProbeDrycontactArrayPort6Description OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor DrycontactArray"
|
|
::= { sensorProbeDrycontactArrayPort6Entry 2 }
|
|
|
|
sensorProbeDrycontactArrayPort6Status OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highCritical(4),
|
|
lowCritical(6),
|
|
sensorError(7),
|
|
relayOn(8),
|
|
relayOff(9)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor"
|
|
::= { sensorProbeDrycontactArrayPort6Entry 4 }
|
|
|
|
sensorProbeDrycontactArrayPort6Online OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
offline(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If this Sensor is currently online"
|
|
::= { sensorProbeDrycontactArrayPort6Entry 5 }
|
|
|
|
sensorProbeDrycontactArrayPort6GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To put online enter a 1, to take offline enter a 2"
|
|
::= { sensorProbeDrycontactArrayPort6Entry 6 }
|
|
|
|
sensorProbeDrycontactArrayPort6NormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
closed(0),
|
|
open(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The normal state of DrycontactArray"
|
|
::= { sensorProbeDrycontactArrayPort6Entry 7 }
|
|
|
|
sensorProbeDrycontactArrayPort6Direction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
input(0),
|
|
output(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To set a drycontact to input enter 0. To set a switch to output enter 1"
|
|
::= { sensorProbeDrycontactArrayPort6Entry 8 }
|
|
|
|
sensorProbeDrycontactArrayPort6ContTimeCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Critical before accepting new Status."
|
|
::= { sensorProbeDrycontactArrayPort6Entry 9 }
|
|
|
|
sensorProbeDrycontactArrayPort6ContTimeNormal OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Normal before accepting new Status."
|
|
::= { sensorProbeDrycontactArrayPort6Entry 10 }
|
|
|
|
sensorProbeDrycontactArrayPort6ManualOutputCycleTime OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drycontact toggle period in seconds for Manual Cycle action."
|
|
::= { sensorProbeDrycontactArrayPort6Entry 24 }
|
|
|
|
sensorProbeDrycontactArrayPort6ManualOutputAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
allow-sensor-control(1),
|
|
turn-on(3),
|
|
turn-off(4),
|
|
cycle-Off-On-Off(7),
|
|
cycle-On-Off-On(8)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Control the Drycontact output manualy"
|
|
::= { sensorProbeDrycontactArrayPort6Entry 25 }
|
|
|
|
sensorProbeDrycontactArrayPort6OutputDescOn OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of Drycontact output On"
|
|
::= { sensorProbeDrycontactArrayPort6Entry 26 }
|
|
|
|
sensorProbeDrycontactArrayPort6OutputDescOff OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of Drycontact output Off"
|
|
::= { sensorProbeDrycontactArrayPort6Entry 27 }
|
|
|
|
sensorProbeDrycontactArrayPort6URL OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor URL link."
|
|
::= { sensorProbeDrycontactArrayPort6Entry 28 }
|
|
|
|
sensorProbeDrycontactArrayPort6OpenURL OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cur-window(0),
|
|
new-window(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Open URL in this browser or open in a new window."
|
|
::= { sensorProbeDrycontactArrayPort6Entry 29 }
|
|
|
|
sensorProbeDrycontactArrayPort6ControlMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
manual-control(0),
|
|
notification-control(1),
|
|
time-control(2),
|
|
thermostat-control(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Control Mode used for selecting the mode to control a Drycontact output."
|
|
::= { sensorProbeDrycontactArrayPort6Entry 30 }
|
|
|
|
sensorProbeDrycontactArrayPort7 OBJECT IDENTIFIER ::= { sensorProbeDrycontactArraySensor 7 }
|
|
sensorProbeDrycontactArrayPort7Number OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of port on the DrycontactArray."
|
|
::= { sensorProbeDrycontactArrayPort7 1 }
|
|
|
|
sensorProbeDrycontactArrayPort7Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorProbeDrycontactArrayPort7Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the data for every Drycontact Sensor in the SensorArray. Each row in the table contains data for a different Drycontact Sensor."
|
|
::= { sensorProbeDrycontactArrayPort7 2 }
|
|
|
|
sensorProbeDrycontactArrayPort7Entry OBJECT-TYPE
|
|
SYNTAX SensorProbeDrycontactArrayPort7Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorProbeDrycontactArrayPort7 Table"
|
|
INDEX { sensorProbeDrycontactArrayPort7Index }
|
|
::= { sensorProbeDrycontactArrayPort7Table 1 }
|
|
|
|
SensorProbeDrycontactArrayPort7Entry ::= SEQUENCE {
|
|
sensorProbeDrycontactArrayPort7Index
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort7Description
|
|
DisplayString,
|
|
sensorProbeDrycontactArrayPort7Status
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort7Online
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort7GoOnline
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort7NormalState
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort7Direction
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort7ContTimeCritical
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort7ContTimeNormal
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort7ManualOutputCycleTime
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort7ManualOutputAction
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort7OutputDescOn
|
|
DisplayString,
|
|
sensorProbeDrycontactArrayPort7OutputDescOff
|
|
DisplayString,
|
|
sensorProbeDrycontactArrayPort7URL
|
|
DisplayString,
|
|
sensorProbeDrycontactArrayPort7OpenURL
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort7ControlMode
|
|
INTEGER
|
|
}
|
|
|
|
sensorProbeDrycontactArrayPort7Index OBJECT-TYPE
|
|
SYNTAX INTEGER (0..7)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value for each sensor DrycontactArray port."
|
|
::= { sensorProbeDrycontactArrayPort7Entry 1 }
|
|
|
|
sensorProbeDrycontactArrayPort7Description OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor DrycontactArray"
|
|
::= { sensorProbeDrycontactArrayPort7Entry 2 }
|
|
|
|
sensorProbeDrycontactArrayPort7Status OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highCritical(4),
|
|
lowCritical(6),
|
|
sensorError(7),
|
|
relayOn(8),
|
|
relayOff(9)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor"
|
|
::= { sensorProbeDrycontactArrayPort7Entry 4 }
|
|
|
|
sensorProbeDrycontactArrayPort7Online OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
offline(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If this Sensor is currently online"
|
|
::= { sensorProbeDrycontactArrayPort7Entry 5 }
|
|
|
|
sensorProbeDrycontactArrayPort7GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To put online enter a 1, to take offline enter a 2"
|
|
::= { sensorProbeDrycontactArrayPort7Entry 6 }
|
|
|
|
sensorProbeDrycontactArrayPort7NormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
closed(0),
|
|
open(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The normal state of DrycontactArray"
|
|
::= { sensorProbeDrycontactArrayPort7Entry 7 }
|
|
|
|
sensorProbeDrycontactArrayPort7Direction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
input(0),
|
|
output(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To set a drycontact to input enter 0. To set a switch to output enter 1"
|
|
::= { sensorProbeDrycontactArrayPort7Entry 8 }
|
|
|
|
sensorProbeDrycontactArrayPort7ContTimeCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Critical before accepting new Status."
|
|
::= { sensorProbeDrycontactArrayPort7Entry 9 }
|
|
|
|
sensorProbeDrycontactArrayPort7ContTimeNormal OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Normal before accepting new Status."
|
|
::= { sensorProbeDrycontactArrayPort7Entry 10 }
|
|
|
|
sensorProbeDrycontactArrayPort7ManualOutputCycleTime OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drycontact toggle period in seconds for Manual Cycle action."
|
|
::= { sensorProbeDrycontactArrayPort7Entry 24 }
|
|
|
|
sensorProbeDrycontactArrayPort7ManualOutputAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
allow-sensor-control(1),
|
|
turn-on(3),
|
|
turn-off(4),
|
|
cycle-Off-On-Off(7),
|
|
cycle-On-Off-On(8)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Control the Drycontact output manualy"
|
|
::= { sensorProbeDrycontactArrayPort7Entry 25 }
|
|
|
|
sensorProbeDrycontactArrayPort7OutputDescOn OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of Drycontact output On"
|
|
::= { sensorProbeDrycontactArrayPort7Entry 26 }
|
|
|
|
sensorProbeDrycontactArrayPort7OutputDescOff OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of Drycontact output Off"
|
|
::= { sensorProbeDrycontactArrayPort7Entry 27 }
|
|
|
|
sensorProbeDrycontactArrayPort7URL OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor URL link."
|
|
::= { sensorProbeDrycontactArrayPort7Entry 28 }
|
|
|
|
sensorProbeDrycontactArrayPort7OpenURL OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cur-window(0),
|
|
new-window(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Open URL in this browser or open in a new window."
|
|
::= { sensorProbeDrycontactArrayPort7Entry 29 }
|
|
|
|
sensorProbeDrycontactArrayPort7ControlMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
manual-control(0),
|
|
notification-control(1),
|
|
time-control(2),
|
|
thermostat-control(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Control Mode used for selecting the mode to control a Drycontact output."
|
|
::= { sensorProbeDrycontactArrayPort7Entry 30 }
|
|
|
|
sensorProbeDrycontactArrayPort8 OBJECT IDENTIFIER ::= { sensorProbeDrycontactArraySensor 8 }
|
|
sensorProbeDrycontactArrayPort8Number OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The total number of port on the DrycontactArray."
|
|
::= { sensorProbeDrycontactArrayPort8 1 }
|
|
|
|
sensorProbeDrycontactArrayPort8Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorProbeDrycontactArrayPort8Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the data for every Drycontact Sensor in the SensorArray. Each row in the table contains data for a different Drycontact Sensor."
|
|
::= { sensorProbeDrycontactArrayPort8 2 }
|
|
|
|
sensorProbeDrycontactArrayPort8Entry OBJECT-TYPE
|
|
SYNTAX SensorProbeDrycontactArrayPort8Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorProbeDrycontactArrayPort8 Table"
|
|
INDEX { sensorProbeDrycontactArrayPort8Index }
|
|
::= { sensorProbeDrycontactArrayPort8Table 1 }
|
|
|
|
SensorProbeDrycontactArrayPort8Entry ::= SEQUENCE {
|
|
sensorProbeDrycontactArrayPort8Index
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort8Description
|
|
DisplayString,
|
|
sensorProbeDrycontactArrayPort8Status
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort8Online
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort8GoOnline
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort8NormalState
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort8Direction
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort8ContTimeCritical
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort8ContTimeNormal
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort8ManualOutputCycleTime
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort8ManualOutputAction
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort8OutputDescOn
|
|
DisplayString,
|
|
sensorProbeDrycontactArrayPort8OutputDescOff
|
|
DisplayString,
|
|
sensorProbeDrycontactArrayPort8URL
|
|
DisplayString,
|
|
sensorProbeDrycontactArrayPort8OpenURL
|
|
INTEGER,
|
|
sensorProbeDrycontactArrayPort8ControlMode
|
|
INTEGER
|
|
}
|
|
|
|
sensorProbeDrycontactArrayPort8Index OBJECT-TYPE
|
|
SYNTAX INTEGER (0..7)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value for each sensor DrycontactArray port."
|
|
::= { sensorProbeDrycontactArrayPort8Entry 1 }
|
|
|
|
sensorProbeDrycontactArrayPort8Description OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor DrycontactArray"
|
|
::= { sensorProbeDrycontactArrayPort8Entry 2 }
|
|
|
|
sensorProbeDrycontactArrayPort8Status OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highCritical(4),
|
|
lowCritical(6),
|
|
sensorError(7),
|
|
relayOn(8),
|
|
relayOff(9)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor"
|
|
::= { sensorProbeDrycontactArrayPort8Entry 4 }
|
|
|
|
sensorProbeDrycontactArrayPort8Online OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
offline(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If this Sensor is currently online"
|
|
::= { sensorProbeDrycontactArrayPort8Entry 5 }
|
|
|
|
sensorProbeDrycontactArrayPort8GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To put online enter a 1, to take offline enter a 2"
|
|
::= { sensorProbeDrycontactArrayPort8Entry 6 }
|
|
|
|
sensorProbeDrycontactArrayPort8NormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
closed(0),
|
|
open(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The normal state of DrycontactArray"
|
|
::= { sensorProbeDrycontactArrayPort8Entry 7 }
|
|
|
|
sensorProbeDrycontactArrayPort8Direction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
input(0),
|
|
output(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To set a drycontact to input enter 0. To set a switch to output enter 1"
|
|
::= { sensorProbeDrycontactArrayPort8Entry 8 }
|
|
|
|
sensorProbeDrycontactArrayPort8ContTimeCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Critical before accepting new Status."
|
|
::= { sensorProbeDrycontactArrayPort8Entry 9 }
|
|
|
|
sensorProbeDrycontactArrayPort8ContTimeNormal OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Normal before accepting new Status."
|
|
::= { sensorProbeDrycontactArrayPort8Entry 10 }
|
|
|
|
sensorProbeDrycontactArrayPort8ManualOutputCycleTime OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drycontact toggle period in seconds for Manual Cycle action."
|
|
::= { sensorProbeDrycontactArrayPort8Entry 24 }
|
|
|
|
sensorProbeDrycontactArrayPort8ManualOutputAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
allow-sensor-control(1),
|
|
turn-on(3),
|
|
turn-off(4),
|
|
cycle-Off-On-Off(7),
|
|
cycle-On-Off-On(8)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Control the Drycontact output manualy"
|
|
::= { sensorProbeDrycontactArrayPort8Entry 25 }
|
|
|
|
sensorProbeDrycontactArrayPort8OutputDescOn OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of Drycontact output On"
|
|
::= { sensorProbeDrycontactArrayPort8Entry 26 }
|
|
|
|
sensorProbeDrycontactArrayPort8OutputDescOff OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of Drycontact output Off"
|
|
::= { sensorProbeDrycontactArrayPort8Entry 27 }
|
|
|
|
sensorProbeDrycontactArrayPort8URL OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor URL link."
|
|
::= { sensorProbeDrycontactArrayPort8Entry 28 }
|
|
|
|
sensorProbeDrycontactArrayPort8OpenURL OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cur-window(0),
|
|
new-window(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Open URL in this browser or open in a new window."
|
|
::= { sensorProbeDrycontactArrayPort8Entry 29 }
|
|
|
|
sensorProbeDrycontactArrayPort8ControlMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
manual-control(0),
|
|
notification-control(1),
|
|
time-control(2),
|
|
thermostat-control(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Control Mode used for selecting the mode to control a Drycontact output."
|
|
::= { sensorProbeDrycontactArrayPort8Entry 30 }
|
|
|
|
sensorProbeDebug OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SP only: Turn on or off debug messages"
|
|
::= { sensorProbeEntry 20 }
|
|
|
|
sensorProbeTrapResend OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If traps for Warning or Error should be resent. Traps for Normal status are sent once"
|
|
::= { sensorProbeEntry 22 }
|
|
|
|
sensorProbeTrapResendInterval OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How often to resend mail or Traps. Enter the number of seconds from 15 to 65535. Mail for WARNING and ERROR are resent at this interval. Traps for Normal status are sent once"
|
|
::= { sensorProbeEntry 23 }
|
|
|
|
sensorProbeSendTraps OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
on(1),
|
|
off(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Turn on or off the sending of traps"
|
|
::= { sensorProbeEntry 24 }
|
|
|
|
sensorProbeTrapDestination OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IP address of the trap destination"
|
|
::= { sensorProbeEntry 25 }
|
|
|
|
sensorProbeTrapCommunity OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The community string of the trap destination"
|
|
::= { sensorProbeEntry 26 }
|
|
|
|
sensorProbeDefaultGateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If the destination is on another network, enter the IP address of the router"
|
|
::= { sensorProbeEntry 27 }
|
|
|
|
sensorProbeSubnetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If the trap destination uses the default gateway"
|
|
::= { sensorProbeEntry 28 }
|
|
|
|
sensorProbeRouteAdd OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SP only: Up to 4, Manual additions to the routing table in the form, Network IP Address, Netmask, Gateway IP address"
|
|
::= { sensorProbeEntry 29 }
|
|
|
|
|
|
sensorProbeSendMail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
on(1),
|
|
off(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Turn on or off the sending of Mail"
|
|
::= { sensorProbeEntry 30 }
|
|
|
|
sensorProbeMailRecpt OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The email address of the Recipient"
|
|
::= { sensorProbeEntry 31 }
|
|
|
|
sensorProbeMailFrom OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The email address of the Sender"
|
|
::= { sensorProbeEntry 32 }
|
|
|
|
sensorProbeMailSMTP OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Address of the SMTP server"
|
|
::= { sensorProbeEntry 33 }
|
|
|
|
sensorProbeMailJpgInline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
inline(1),
|
|
link(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If the jpg for this event is sent as an http link or is included with mail as an attachment"
|
|
::= { sensorProbeEntry 34 }
|
|
|
|
sensorProbeMailResendInterval OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How often to resend mail or Traps. Enter the number of seconds from 10 to 60. Mail for WARNING and ERROR are resent at this interval. Mail for Normal status are sent once"
|
|
::= { sensorProbeEntry 36 }
|
|
|
|
sensorProbeMailMaxResend OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum number of times to resend mail. If set to 0 only send once. The maximum value is 5"
|
|
::= { sensorProbeEntry 37 }
|
|
|
|
sensorProbeMailLastStatus OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the most recent attempt to send an email"
|
|
::= { sensorProbeEntry 39 }
|
|
|
|
sensorProbeSupportMailRcpt OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SP8L only: E-Mail address of support"
|
|
::= { sensorProbeEntry 40 }
|
|
|
|
sensorProbeCameraServerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorProbeCameraServerEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"CP8 Only: This table contains the Camera Server features, This allows the sensorProbe to connect to a sensorProbe"
|
|
::= { sensorProbeEntry 42 }
|
|
|
|
sensorProbeCameraServerEntry OBJECT-TYPE
|
|
SYNTAX SensorProbeCameraServerEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorProbeCameraServerEntry Table"
|
|
INDEX { sensorProbeCameraServerIndex }
|
|
::= { sensorProbeCameraServerTable 1 }
|
|
|
|
SensorProbeCameraServerEntry ::= SEQUENCE {
|
|
sensorProbeCameraServerClientOnline
|
|
INTEGER,
|
|
sensorProbeCameraServerClientGoOnline
|
|
INTEGER,
|
|
sensorProbeCameraServerClientIP
|
|
IpAddress,
|
|
sensorProbeCameraServerClientSetPassword
|
|
DisplayString,
|
|
sensorProbeCameraServerIndex
|
|
INTEGER,
|
|
sensorProbeJavaTimeOut
|
|
INTEGER,
|
|
sensorProbeJpegQualityFactor
|
|
INTEGER,
|
|
sensorProbeCameraDescription
|
|
DisplayString,
|
|
sensorProbeCameraRotate
|
|
INTEGER,
|
|
sensorProbeCameraResolution
|
|
INTEGER,
|
|
sensorProbePTZRotateRelative
|
|
DisplayString,
|
|
sensorProbePTZRotateAbsolute
|
|
DisplayString,
|
|
sensorProbeAudioAttachChannel
|
|
INTEGER,
|
|
sensorProbePTZEnable
|
|
INTEGER,
|
|
sensorProbePTZBrand
|
|
INTEGER,
|
|
sensorProbePTZPanTiltUntilEnd
|
|
INTEGER
|
|
}
|
|
|
|
|
|
sensorProbeCameraServerClientOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
offline(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If this Client is currently online"
|
|
::= { sensorProbeCameraServerEntry 1 }
|
|
|
|
sensorProbeCameraServerClientGoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To put this Client online enter a 1, to take offline enter a 2"
|
|
::= { sensorProbeCameraServerEntry 2 }
|
|
|
|
sensorProbeCameraServerClientIP OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IP address of the sensorProbe, used to send snmp keep alive messages"
|
|
::= { sensorProbeCameraServerEntry 3 }
|
|
|
|
sensorProbeCameraServerClientSetPassword OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SP Only: The Set Password for the snmp keep alive messages sent to the sensorProbes"
|
|
::= { sensorProbeCameraServerEntry 4 }
|
|
|
|
sensorProbeCameraServerIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..9)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index into the Camera table"
|
|
::= { sensorProbeCameraServerEntry 5 }
|
|
|
|
sensorProbeJavaTimeOut OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Timeout in minutes for Java client"
|
|
::= { sensorProbeCameraServerEntry 6 }
|
|
|
|
sensorProbeJpegQualityFactor OBJECT-TYPE
|
|
SYNTAX INTEGER (5..95)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Quality factor of jpeg image"
|
|
::= { sensorProbeCameraServerEntry 7 }
|
|
|
|
sensorProbeCameraDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A description of camera"
|
|
::= { sensorProbeCameraServerEntry 8 }
|
|
|
|
sensorProbeCameraRotate OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
nonRotate(0),
|
|
rotate(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Rotate of this camera"
|
|
::= { sensorProbeCameraServerEntry 9 }
|
|
|
|
sensorProbeCameraResolution OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
resolution320x240(0),
|
|
resolution640x480(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Resolution of camera"
|
|
::= { sensorProbeCameraServerEntry 10 }
|
|
|
|
sensorProbePTZRotateRelative OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Control PTZ by put Direction and step 'DIR STEP' when direction 0 or 1 is LEFT or RIGH and 2 or 3 is UP or DOWN "
|
|
::= { sensorProbeCameraServerEntry 11 }
|
|
|
|
sensorProbePTZRotateAbsolute OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Control PTZ by put position of x and y 'POS_X POS_Y' value of position is 0 to 100"
|
|
::= { sensorProbeCameraServerEntry 12 }
|
|
|
|
sensorProbeAudioAttachChannel OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notAttachAudio(0),
|
|
attachAudio(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Disable/Enable audio attachment"
|
|
::= { sensorProbeCameraServerEntry 13 }
|
|
|
|
sensorProbePTZEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enableInternal(1),
|
|
enableExternal(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Disable/Enable Ptz controller"
|
|
::= { sensorProbeCameraServerEntry 14 }
|
|
|
|
sensorProbePTZBrand OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
generalBrand(0),
|
|
akcpBrand(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"PTZ Brand"
|
|
::= { sensorProbeCameraServerEntry 15 }
|
|
|
|
sensorProbePTZPanTiltUntilEnd OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
stop(0),
|
|
right(1),
|
|
left(2),
|
|
up(3),
|
|
down(4),
|
|
right-up(5),
|
|
right-down(6),
|
|
left-up(7),
|
|
left-down(8)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pan or Tilt PTZ until endpoint"
|
|
::= { sensorProbeCameraServerEntry 16 }
|
|
|
|
|
|
sensorProbeTrapMailPollInterval OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SP Only: How often the sensor thresholds are tested before sending traps or mail. This can vary from 3 to 15 seconds"
|
|
::= { sensorProbeEntry 50 }
|
|
|
|
sensorProbeSendTestMail OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Send out an email test message"
|
|
::= { sensorProbeEntry 51 }
|
|
|
|
sensorProbeLastSystemError OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A text string containing the description of the last system error"
|
|
::= { sensorProbeEntry 52 }
|
|
|
|
sensorProbeDataCollectionPeriod OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of minutes between collections of the data logger. This can vary from 1 to 60 minutes"
|
|
::= { sensorProbeEntry 53 }
|
|
|
|
sensorProbeMailTimeout OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of seconds to wait for a timeout while sending email This can vary from 10 to 30 seconds"
|
|
::= { sensorProbeEntry 54 }
|
|
|
|
sensorProbeAutoSense OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable Auto-sense feature"
|
|
::= { sensorProbeEntry 55 }
|
|
|
|
sensorProbeChecksum OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SP Only: The Flash Checksum, computed dynamically whenever this object is read"
|
|
::= { sensorProbeEntry 56 }
|
|
|
|
sensorProbeUsePassword OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
usePassword(0),
|
|
doNotUsePassword(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Determines whether or not the set and get community are used to check for access rights"
|
|
::= { sensorProbeEntry 57 }
|
|
|
|
sensorProbeDisplayLogo OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable or Disable the display of the logo"
|
|
::= { sensorProbeEntry 59 }
|
|
|
|
sensorProbeTrapType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
specificTypeTrap(1),
|
|
generalTypeTrap(2),
|
|
bothTypeTraps(3),
|
|
statusTypeTraps(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Whether to generate a trap that covers all sensors, a specific trap for each sensor, or both types of traps"
|
|
::= { sensorProbeEntry 60 }
|
|
|
|
sensorProbeMailCC OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The email address of the CC"
|
|
::= { sensorProbeEntry 61 }
|
|
|
|
sensorProbeAllowIPChange OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This disables the changing of the IP address. The default is to enable changing the IP address"
|
|
::= { sensorProbeEntry 62 }
|
|
|
|
sensorProbeTimeOfDay OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The time of day in the format day/month/year hour(1-24):minutes:seconds for example 23/10/02 12:45:06"
|
|
::= { sensorProbeEntry 65 }
|
|
|
|
sensorProbeEnableSysLog OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enableLogToFlash(1),
|
|
enableLogToNetAndFlash(2),
|
|
disable(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This enables sysLog Messages,including logging to the Net. The Destination IP of the net messages is the same as the source IP of the sender of this command"
|
|
::= { sensorProbeEntry 66 }
|
|
|
|
sensorProbeReadSysLog OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
lastMessage(1),
|
|
allMessages(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Return the sysLog Message in the snmp PDU and if enableLogToNetAndFlash in sensorProbeEnableSysLog, also send in debug message format, A Write of a 2 will return all of the messages in debug format"
|
|
::= { sensorProbeEntry 67 }
|
|
|
|
sensorProbeClearSysLog OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
allMessages(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Delete all entries in the sys log"
|
|
::= { sensorProbeEntry 68 }
|
|
|
|
sensorProbeSyslogDestIP OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IP Address of the Syslog server. Note: This must be in dotted decimal form"
|
|
::= { sensorProbeEntry 69 }
|
|
|
|
sensorProbeSyslogPort OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Port Number of the Syslog server."
|
|
::= { sensorProbeEntry 70 }
|
|
|
|
sensorProbeSetSyslogMsgPrefix OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SP Only: The Prefix message of the Syslog message"
|
|
::= { sensorProbeEntry 71 }
|
|
|
|
--
|
|
-- sensorProbeEntry 72 is reserved for sensorProbeLanFullDuplex ( SP Only )
|
|
--
|
|
|
|
--
|
|
-- sensorProbeEntry 73 is reserved for sensorProbeExpectedMicrocodeCRC ( SP Only )
|
|
--
|
|
|
|
--
|
|
-- sensorProbeEntry 74 is reserved for sensorProbeExpectedMicrocodeLength ( SP Only )
|
|
--
|
|
|
|
--
|
|
-- sensorProbeEntry 75 is reserved for sensorProbeActualMicrocodeCRC ( SP Only )
|
|
--
|
|
|
|
--
|
|
-- sensorProbeEntry 76 is reserved for sensorProbeExpectedBootCRC ( SP Only )
|
|
--
|
|
|
|
--
|
|
-- sensorProbeEntry 77 is reserved for sensorProbeActualBootCRC ( SP Only )
|
|
--
|
|
|
|
--
|
|
-- sensorProbeEntry 78 is reserved for sensorProbeBootVersion ( SP Only )
|
|
--
|
|
|
|
--
|
|
-- sensorProbeEntry 80 is reserved for sensorProbeAdcCalibrate
|
|
--
|
|
|
|
sensorProbeTimeZone OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"System time zone"
|
|
::= { sensorProbeEntry 81 }
|
|
|
|
--
|
|
-- sensorProbeEntry 82 is reserved for sensorProbeExtraDryContactEnable ( SP Only )
|
|
--
|
|
|
|
sensorProbeMegaVersion OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Version number of mega board"
|
|
::= { sensorProbeEntry 83 }
|
|
|
|
sensorProbeNtpMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notUse(0),
|
|
oneTime(1),
|
|
onSystemStartUp(2),
|
|
onceAMounth(3),
|
|
onceAWeek(4),
|
|
onceADay(5),
|
|
onceAnHour(6),
|
|
continuous(7)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Mode to synchronous with ntp server"
|
|
::= { sensorProbeEntry 84 }
|
|
|
|
sensorProbeNtpServer OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"NTP server which this machine synchronous with"
|
|
::= { sensorProbeEntry 85 }
|
|
|
|
--
|
|
-- sensorProbeEntry 86 is reserved for SensorProbeModel string which is used internaly (AKCP).
|
|
--
|
|
|
|
sensorProbeSMTPAuth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This enables the SMTP authentication"
|
|
::= { sensorProbeEntry 87 }
|
|
|
|
sensorProbeSMTPLogin OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The username used to login into SMTP server"
|
|
::= { sensorProbeEntry 88 }
|
|
|
|
sensorProbeSMTPPassword OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The password used to login into SMTP server"
|
|
::= { sensorProbeEntry 89 }
|
|
|
|
sensorProbeDNSServer OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the DNS server"
|
|
::= { sensorProbeEntry 90 }
|
|
|
|
sensorProbeAltWebPort OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The alternative for a port number 80 used to access the web interface"
|
|
::= { sensorProbeEntry 91 }
|
|
|
|
sensorProbeNumberOfSensorPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of sensor ports(regardless of their current state)"
|
|
::= { sensorProbeEntry 92 }
|
|
|
|
sensorProbeSendTrapsAlive OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
on(1),
|
|
off(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"On or off send keep alive traps."
|
|
::= { sensorProbeEntry 93 }
|
|
|
|
sensorProbeTrapReIntervalAlive OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time between each keep alive trap."
|
|
::= { sensorProbeEntry 94 }
|
|
|
|
sensorProbeUseCamera OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"On or off camera."
|
|
::= { sensorProbeEntry 95 }
|
|
|
|
sensorProbeAdcCalibratePort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Calibrate value for analog sensor."
|
|
::= { sensorProbeEntry 96 }
|
|
|
|
--
|
|
-- sensorProbeEntry 97 is reseverd for future using with Linux version (AKCP).
|
|
--
|
|
|
|
sensorProbeMailSubject OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Email Subject."
|
|
::= { sensorProbeEntry 98 }
|
|
|
|
sensorProbeSnmpPort OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SP Only: Port number used to access snmp"
|
|
::= { sensorProbeEntry 99 }
|
|
|
|
sensorProbeSnmpTrapPort OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SP Only: Port number used to access trap snmp"
|
|
::= { sensorProbeEntry 100 }
|
|
|
|
sensorProbeSnmpIndexingMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
index0(0),
|
|
index1(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"CP8 Only: Snmp table index starting from 0 or 1 "
|
|
::= { sensorProbeEntry 101 }
|
|
|
|
--
|
|
-- sensorProbeEntry 102 is reserved for sensorProbeSensorSummary
|
|
--
|
|
sensorProbeNotifyBoot OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SP2 Only: Enable Notify on boot up"
|
|
::= { sensorProbeEntry 103 }
|
|
|
|
sensorProbeDelayNotifyBoot OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SP2 Only: Delay time for boot up notify"
|
|
::= { sensorProbeEntry 104 }
|
|
|
|
sensorProbeSmtpPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SMTP Port number used to send email"
|
|
::= { sensorProbeEntry 105 }
|
|
|
|
sensorProbeReboot OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reboot SP2/SP8 set to 1"
|
|
::= { sensorProbeEntry 106 }
|
|
|
|
sensorProbeServerEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enable database changed notify feature"
|
|
::= { sensorProbeEntry 107 }
|
|
|
|
sensorProbeFirmwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Current firmware version"
|
|
::= { sensorProbeEntry 108 }
|
|
|
|
sensorProbeProductType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
sensorProbe2(1),
|
|
sensorProbe8(2),
|
|
sensorProbeLinuxWithoutUSB(3),
|
|
sensorProbeLinuxWithUSB(4),
|
|
securityProbe(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Product type"
|
|
::= { sensorProbeEntry 109 }
|
|
|
|
sensorProbeRequestResendTrap OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SP only: Send immediately all traps by set to 1"
|
|
::= { sensorProbeEntry 110 }
|
|
|
|
--
|
|
-- sensorProbeEntry 111 is reserved for Server Project
|
|
--
|
|
|
|
sensorProbeSeparateEmail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notSeparate(0),
|
|
separate(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SP only: Separate Email by set 1 for not Separate Email set 0"
|
|
::= { sensorProbeEntry 112 }
|
|
|
|
sensorProbeMailCustom OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal(0),
|
|
custom(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SP only: Custom mail is removed 'http://' in the mail footer"
|
|
::= { sensorProbeEntry 113 }
|
|
|
|
sensorProbeUntidePassword OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
tidePassword(0),
|
|
untidePassword(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Use web password as SNMP password"
|
|
::= { sensorProbeEntry 114 }
|
|
|
|
sensorProbeWebPassword OBJECT IDENTIFIER ::= { sensorProbeEntry 115 }
|
|
sensorProbeWebAdminPassword OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Password Admin for login web and other connections"
|
|
::= { sensorProbeWebPassword 1 }
|
|
|
|
sensorProbeWebUserPassword OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Password User for login web and other connections"
|
|
::= { sensorProbeWebPassword 2 }
|
|
|
|
sensorProbeReloadNetwork OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
reload(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set 1 for reload network seting"
|
|
::= { sensorProbeEntry 116 }
|
|
|
|
sensorProbeStatusNumber OBJECT IDENTIFIER ::= { sensorProbeEntry 117 }
|
|
sensorProbeStatusNumberNotNormal OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of sensor status is Warning, Critical and Sensor Error"
|
|
::= { sensorProbeStatusNumber 1 }
|
|
|
|
sensorProbeStatusNumberCriticalAndError OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of sensor status is Critical and Sensor Error"
|
|
::= { sensorProbeStatusNumber 2 }
|
|
|
|
sensorProbeStatusNumberError OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of sensor status is Sensor Error"
|
|
::= { sensorProbeStatusNumber 3 }
|
|
|
|
sensorProbeTypeName OBJECT IDENTIFIER ::= { sensorProbeEntry 118 }
|
|
sensorProbeTypeTemperatureName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of Sensor Type Name on web interface"
|
|
::= { sensorProbeTypeName 1 }
|
|
|
|
sensorProbeTypeSHT11HumidityName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of Sensor Type Name on web interface"
|
|
::= { sensorProbeTypeName 2 }
|
|
|
|
sensorProbeTypeSHT11TempName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of Sensor Type Name on web interface"
|
|
::= { sensorProbeTypeName 3 }
|
|
|
|
sensorProbeType4to20MAName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of Sensor Type Name on web interface"
|
|
::= { sensorProbeTypeName 4 }
|
|
|
|
sensorProbeTypeDCvoltageName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of Sensor Type Name on web interface"
|
|
::= { sensorProbeTypeName 5 }
|
|
|
|
sensorProbeTypeAirflowName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of Sensor Type Name on web interface"
|
|
::= { sensorProbeTypeName 6 }
|
|
|
|
sensorProbeTypeDrycontactInoutName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of Sensor Type Name on web interface"
|
|
::= { sensorProbeTypeName 7 }
|
|
|
|
sensorProbeTypeDrycontactInputName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of Sensor Type Name on web interface"
|
|
::= { sensorProbeTypeName 8 }
|
|
|
|
sensorProbeTypeMotionName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of Sensor Type Name on web interface"
|
|
::= { sensorProbeTypeName 9 }
|
|
|
|
sensorProbeTypeWaterName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of Sensor Type Name on web interface"
|
|
::= { sensorProbeTypeName 10 }
|
|
|
|
sensorProbeTypeSecurityName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of Sensor Type Name on web interface"
|
|
::= { sensorProbeTypeName 11 }
|
|
|
|
sensorProbeTypeSirenName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of Sensor Type Name on web interface"
|
|
::= { sensorProbeTypeName 12 }
|
|
|
|
sensorProbeTypeRelayName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of Sensor Type Name on web interface"
|
|
::= { sensorProbeTypeName 13 }
|
|
|
|
sensorProbeTypeACvoltageName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of Sensor Type Name on web interface"
|
|
::= { sensorProbeTypeName 14 }
|
|
|
|
sensorProbeTypeADE7763VRMSName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of Sensor Type Name on web interface"
|
|
::= { sensorProbeTypeName 15 }
|
|
|
|
sensorProbeTypeADE7763IRMSName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of Sensor Type Name on web interface"
|
|
::= { sensorProbeTypeName 16 }
|
|
|
|
sensorProbeTypeADE7763WattName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of Sensor Type Name on web interface"
|
|
::= { sensorProbeTypeName 17 }
|
|
|
|
sensorProbeTypeADE7763WatthourName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of Sensor Type Name on web interface"
|
|
::= { sensorProbeTypeName 18 }
|
|
|
|
sensorProbeTypePCF8574XRelayName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of Sensor Type Name on web interface"
|
|
::= { sensorProbeTypeName 19 }
|
|
|
|
sensorProbeTypeThermocoupleName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of Sensor Type Name on web interface"
|
|
::= { sensorProbeTypeName 20 }
|
|
|
|
sensorProbeTypeSmokeName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of Sensor Type Name on web interface"
|
|
::= { sensorProbeTypeName 21 }
|
|
|
|
sensorProbeTypeXDryName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of Sensor Type Name on web interface"
|
|
::= { sensorProbeTypeName 22 }
|
|
|
|
sensorProbeTypeTemperatureArrayName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of Sensor Type Name on web interface"
|
|
::= { sensorProbeTypeName 23 }
|
|
|
|
sensorProbeTypeWaterRopeName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of Sensor Type Name on web interface"
|
|
::= { sensorProbeTypeName 24 }
|
|
|
|
sensorProbeTypeFuelLevelName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of Sensor Type Name on web interface"
|
|
::= { sensorProbeTypeName 25 }
|
|
|
|
sensorProbeTypeTankSenderName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of Sensor Type Name on web interface"
|
|
::= { sensorProbeTypeName 26 }
|
|
|
|
sensorProbeTypeThurmostatName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of Sensor Type Name on web interface"
|
|
::= { sensorProbeTypeName 128 }
|
|
|
|
sensorProbeTypeVirtualName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of Sensor Type Name on web interface"
|
|
::= { sensorProbeTypeName 129 }
|
|
|
|
sensorProbeTypeSoundName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of Sensor Type Name on web interface"
|
|
::= { sensorProbeTypeName 130 }
|
|
|
|
sensorProbeTypeSoftMotionName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of Sensor Type Name on web interface"
|
|
::= { sensorProbeTypeName 131 }
|
|
|
|
sensorProbeTypeNoSignalName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of Sensor Type Name on web interface"
|
|
::= { sensorProbeTypeName 132 }
|
|
|
|
sensorProbeTypePowerMeterName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of Sensor Type Name on web interface"
|
|
::= { sensorProbeTypeName 134 }
|
|
|
|
sensorProbeTypeSHT11Name OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of Sensor Type Name on web interface"
|
|
::= { sensorProbeTypeName 135 }
|
|
|
|
sensorProbeTypeADE7763Name OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of Sensor Type Name on web interface"
|
|
::= { sensorProbeTypeName 136 }
|
|
|
|
sensorProbeProductRevision OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SP only: Revision number"
|
|
::= { sensorProbeEntry 119 }
|
|
|
|
securityProbe OBJECT IDENTIFIER ::= { akcp 2 }
|
|
|
|
secSummary OBJECT IDENTIFIER ::= { securityProbe 1 }
|
|
|
|
secDevice OBJECT IDENTIFIER ::= { securityProbe 2 }
|
|
|
|
deviceTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DeviceEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the property for every plugged-in device."
|
|
::= { secDevice 1 }
|
|
|
|
deviceEntry OBJECT-TYPE
|
|
SYNTAX DeviceEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the deviceEntry Table"
|
|
INDEX { deviceIndex }
|
|
::= { deviceTable 1 }
|
|
|
|
DeviceEntry ::= SEQUENCE {
|
|
deviceIndex
|
|
INTEGER,
|
|
deviceDescription
|
|
DisplayString,
|
|
deviceType
|
|
INTEGER,
|
|
deviceInfo
|
|
DisplayString,
|
|
deviceStatus
|
|
INTEGER
|
|
}
|
|
|
|
deviceIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..184549375)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index into the device table"
|
|
::= { deviceEntry 1 }
|
|
|
|
deviceDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this device"
|
|
::= { deviceEntry 2 }
|
|
|
|
deviceType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"..."
|
|
::= { deviceEntry 3 }
|
|
|
|
deviceInfo OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A information of this device"
|
|
::= { deviceEntry 4 }
|
|
|
|
deviceStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"..."
|
|
::= { deviceEntry 5 }
|
|
|
|
deviceIntelligentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DeviceIntelligentEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the property for every plugged-in device."
|
|
::= { secDevice 2 }
|
|
|
|
deviceIntelligentEntry OBJECT-TYPE
|
|
SYNTAX DeviceIntelligentEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the deviceEntry Table"
|
|
INDEX { deviceIntelligentIndex }
|
|
::= { deviceIntelligentTable 1 }
|
|
|
|
DeviceIntelligentEntry ::= SEQUENCE {
|
|
deviceIntelligentIndex
|
|
INTEGER,
|
|
deviceIntelligentDescription
|
|
DisplayString,
|
|
deviceIntelligentInfo
|
|
DisplayString,
|
|
deviceIntelligentStatus
|
|
INTEGER,
|
|
sensorIntelligentTypeSelected
|
|
INTEGER,
|
|
sensorIntelligentPort1GoOnline
|
|
INTEGER,
|
|
sensorIntelligentPort2GoOnline
|
|
INTEGER,
|
|
sensorIntelligentPort3GoOnline
|
|
INTEGER,
|
|
sensorIntelligentPort4GoOnline
|
|
INTEGER,
|
|
sensorIntelligentPort5GoOnline
|
|
INTEGER,
|
|
sensorIntelligentPort6GoOnline
|
|
INTEGER,
|
|
sensorIntelligentPort7GoOnline
|
|
INTEGER,
|
|
sensorIntelligentPort8GoOnline
|
|
INTEGER
|
|
}
|
|
deviceIntelligentIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index into the deviceIntelligent table"
|
|
::= { deviceIntelligentEntry 1 }
|
|
|
|
deviceIntelligentDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this device"
|
|
::= { deviceIntelligentEntry 2 }
|
|
|
|
deviceIntelligentInfo OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A information of this device"
|
|
::= { deviceIntelligentEntry 4 }
|
|
|
|
deviceIntelligentStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"..."
|
|
::= { deviceIntelligentEntry 5 }
|
|
|
|
sensorIntelligentTypeSelected OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"..."
|
|
::= { deviceIntelligentEntry 6 }
|
|
|
|
sensorIntelligentPort1GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"..."
|
|
::= { deviceIntelligentEntry 100 }
|
|
|
|
sensorIntelligentPort2GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"..."
|
|
::= { deviceIntelligentEntry 101 }
|
|
|
|
sensorIntelligentPort3GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"..."
|
|
::= { deviceIntelligentEntry 102 }
|
|
|
|
sensorIntelligentPort4GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"..."
|
|
::= { deviceIntelligentEntry 103 }
|
|
|
|
sensorIntelligentPort5GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"..."
|
|
::= { deviceIntelligentEntry 104 }
|
|
|
|
sensorIntelligentPort6GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"..."
|
|
::= { deviceIntelligentEntry 105 }
|
|
|
|
sensorIntelligentPort7GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"..."
|
|
::= { deviceIntelligentEntry 106 }
|
|
|
|
sensorIntelligentPort8GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"..."
|
|
::= { deviceIntelligentEntry 107 }
|
|
|
|
deviceDryContactTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DeviceDryContactEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the property for every plugged-in device."
|
|
::= { secDevice 3 }
|
|
|
|
deviceDryContactEntry OBJECT-TYPE
|
|
SYNTAX DeviceDryContactEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the deviceEntry Table"
|
|
INDEX { deviceDryContactIndex }
|
|
::= { deviceDryContactTable 1 }
|
|
|
|
DeviceDryContactEntry ::= SEQUENCE {
|
|
deviceDryContactIndex
|
|
INTEGER,
|
|
deviceDryContactDescription
|
|
DisplayString,
|
|
deviceDryContactInfo
|
|
DisplayString,
|
|
deviceDryContactStatus
|
|
INTEGER,
|
|
sensorDryContactPort1GoOnline
|
|
INTEGER,
|
|
sensorDryContactPort2GoOnline
|
|
INTEGER,
|
|
sensorDryContactPort3GoOnline
|
|
INTEGER,
|
|
sensorDryContactPort4GoOnline
|
|
INTEGER,
|
|
sensorDryContactPort5GoOnline
|
|
INTEGER,
|
|
sensorDryContactPort6GoOnline
|
|
INTEGER,
|
|
sensorDryContactPort7GoOnline
|
|
INTEGER,
|
|
sensorDryContactPort8GoOnline
|
|
INTEGER,
|
|
sensorDryContactPort9GoOnline
|
|
INTEGER,
|
|
sensorDryContactPort10GoOnline
|
|
INTEGER,
|
|
sensorDryContactPort11GoOnline
|
|
INTEGER,
|
|
sensorDryContactPort12GoOnline
|
|
INTEGER,
|
|
sensorDryContactPort13GoOnline
|
|
INTEGER,
|
|
sensorDryContactPort14GoOnline
|
|
INTEGER,
|
|
sensorDryContactPort15GoOnline
|
|
INTEGER,
|
|
sensorDryContactPort16GoOnline
|
|
INTEGER
|
|
}
|
|
|
|
deviceDryContactIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index into the deviceDryContact table"
|
|
::= { deviceDryContactEntry 1 }
|
|
|
|
deviceDryContactDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this device"
|
|
::= { deviceDryContactEntry 2 }
|
|
|
|
deviceDryContactInfo OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A information of this device"
|
|
::= { deviceDryContactEntry 4 }
|
|
|
|
deviceDryContactStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"..."
|
|
::= { deviceDryContactEntry 5 }
|
|
|
|
sensorDryContactPort1GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"..."
|
|
::= { deviceDryContactEntry 100 }
|
|
|
|
sensorDryContactPort2GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"..."
|
|
::= { deviceDryContactEntry 101 }
|
|
|
|
sensorDryContactPort3GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"..."
|
|
::= { deviceDryContactEntry 102 }
|
|
|
|
sensorDryContactPort4GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"..."
|
|
::= { deviceDryContactEntry 103 }
|
|
|
|
sensorDryContactPort5GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"..."
|
|
::= { deviceDryContactEntry 104 }
|
|
|
|
sensorDryContactPort6GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"..."
|
|
::= { deviceDryContactEntry 105 }
|
|
|
|
sensorDryContactPort7GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"..."
|
|
::= { deviceDryContactEntry 106 }
|
|
|
|
sensorDryContactPort8GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"..."
|
|
::= { deviceDryContactEntry 107 }
|
|
|
|
sensorDryContactPort9GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"..."
|
|
::= { deviceDryContactEntry 108 }
|
|
|
|
sensorDryContactPort10GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"..."
|
|
::= { deviceDryContactEntry 109 }
|
|
|
|
sensorDryContactPort11GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"..."
|
|
::= { deviceDryContactEntry 110 }
|
|
|
|
sensorDryContactPort12GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"..."
|
|
::= { deviceDryContactEntry 111 }
|
|
|
|
sensorDryContactPort13GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"..."
|
|
::= { deviceDryContactEntry 112 }
|
|
|
|
sensorDryContactPort14GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"..."
|
|
::= { deviceDryContactEntry 113 }
|
|
|
|
sensorDryContactPort15GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"..."
|
|
::= { deviceDryContactEntry 114 }
|
|
|
|
sensorDryContactPort16GoOnline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
goOnline(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"..."
|
|
::= { deviceDryContactEntry 115 }
|
|
|
|
|
|
secSensor OBJECT IDENTIFIER ::= { securityProbe 3 }
|
|
|
|
sensorTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the property and reading value for every sensor."
|
|
::= { secSensor 1 }
|
|
|
|
--/* Begin of sensorEntry */
|
|
|
|
sensorEntry OBJECT-TYPE
|
|
SYNTAX SensorEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorTable Table"
|
|
INDEX { sensorIndex }
|
|
::= { sensorTable 1 }
|
|
|
|
SensorEntry ::= SEQUENCE {
|
|
sensorIndex
|
|
INTEGER,
|
|
sensorDescription
|
|
DisplayString,
|
|
sensorType
|
|
INTEGER,
|
|
sensorValue
|
|
INTEGER,
|
|
sensorUnit
|
|
DisplayString,
|
|
sensorStatus
|
|
INTEGER,
|
|
sensorGoOffline
|
|
INTEGER,
|
|
sensorPort
|
|
INTEGER,
|
|
sensorSubPort
|
|
INTEGER,
|
|
sensorDeviceIndex
|
|
INTEGER,
|
|
sensorDisplayStyle
|
|
INTEGER,
|
|
sensorHighCriticalDescription
|
|
DisplayString,
|
|
sensorLowCriticalDescription
|
|
DisplayString,
|
|
sensorNormalDescription
|
|
DisplayString,
|
|
sensorLowWarningDescription
|
|
DisplayString,
|
|
sensorHighWarningDescription
|
|
DisplayString,
|
|
sensorErrorDescription
|
|
DisplayString,
|
|
sensorOnDescription
|
|
DisplayString,
|
|
sensorOffDescription
|
|
DisplayString,
|
|
sensorHighCriticalColor
|
|
INTEGER,
|
|
sensorLowCriticalColor
|
|
INTEGER,
|
|
sensorNormalColor
|
|
INTEGER,
|
|
sensorLowWarningColor
|
|
INTEGER,
|
|
sensorHighWarningColor
|
|
INTEGER,
|
|
sensorErrorColor
|
|
INTEGER,
|
|
sensorOnColor
|
|
INTEGER,
|
|
sensorOffColor
|
|
INTEGER
|
|
}
|
|
|
|
sensorIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index into the sensor table"
|
|
::= { sensorEntry 1 }
|
|
|
|
sensorDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor"
|
|
::= { sensorEntry 2 }
|
|
|
|
sensorType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
temperature(1),
|
|
humidity(2),
|
|
temperature2(3),
|
|
four-20mA(4),
|
|
dcvoltage(5),
|
|
airflow(6),
|
|
io(7),
|
|
drycontact(8),
|
|
motion(9),
|
|
water(10),
|
|
security(11),
|
|
siren(12),
|
|
relay(13),
|
|
acvoltage(14),
|
|
vrms(15),
|
|
irms(16),
|
|
watt(17),
|
|
watthour(18),
|
|
xrelay(19),
|
|
thermocouple(20),
|
|
smoke(21),
|
|
drycontact-array(22),
|
|
temperature-array(23),
|
|
thermostat(128),
|
|
virtual(129),
|
|
sound(130),
|
|
softmotion(131),
|
|
camera-dummy(132),
|
|
board-state(133),
|
|
nosignal(224),
|
|
test(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enter the type of this Sensor"
|
|
::= { sensorEntry 3 }
|
|
|
|
sensorValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value in this sensor"
|
|
::= { sensorEntry 4 }
|
|
|
|
sensorUnit OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit string"
|
|
::= { sensorEntry 5 }
|
|
|
|
sensorStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highWarning(3),
|
|
highCritical(4),
|
|
lowWarning(5),
|
|
lowCritical(6),
|
|
sensorError(7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this sensor"
|
|
::= { sensorEntry 6 }
|
|
|
|
sensorGoOffline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To take offline enter a 2"
|
|
::= { sensorEntry 8 }
|
|
|
|
sensorPort OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor port"
|
|
::= { sensorEntry 35 }
|
|
|
|
sensorSubPort OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor sub port"
|
|
::= { sensorEntry 36 }
|
|
|
|
sensorDeviceIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Device Index of sensor"
|
|
::= { sensorEntry 37 }
|
|
|
|
sensorDisplayStyle OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
basic(0),
|
|
gauge(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Temperature display style"
|
|
::= { sensorEntry 45 }
|
|
|
|
sensorHighCriticalDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A HighCritical Description of this sensor"
|
|
::= { sensorEntry 46 }
|
|
|
|
sensorLowCriticalDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A LowCritical Description of this sensor"
|
|
::= { sensorEntry 47 }
|
|
|
|
sensorNormalDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Normal Description of this sensor"
|
|
::= { sensorEntry 48 }
|
|
|
|
sensorLowWarningDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A LowWarning Description of this sensor"
|
|
::= { sensorEntry 49 }
|
|
|
|
sensorHighWarningDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A HighWarning Description of this sensor"
|
|
::= { sensorEntry 50 }
|
|
|
|
sensorErrorDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A SensorError Description of this sensor"
|
|
::= { sensorEntry 51 }
|
|
|
|
sensorOnDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A On Description of this sensor"
|
|
::= { sensorEntry 52 }
|
|
|
|
sensorOffDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Off Description of this sensor"
|
|
::= { sensorEntry 53 }
|
|
|
|
sensorHighCriticalColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A HighCritical Color of this sensor"
|
|
::= { sensorEntry 54 }
|
|
|
|
sensorLowCriticalColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A LowCritical Color of this sensor"
|
|
::= { sensorEntry 55 }
|
|
|
|
sensorNormalColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Normal Color of this sensor"
|
|
::= { sensorEntry 56 }
|
|
|
|
sensorLowWarningColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A LowWarning Color of this sensor"
|
|
::= { sensorEntry 57 }
|
|
|
|
sensorHighWarningColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A HighWarning Color of this sensor"
|
|
::= { sensorEntry 58 }
|
|
|
|
sensorErrorColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A SensorError Color of this sensor"
|
|
::= { sensorEntry 59 }
|
|
|
|
sensorOnColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A On Color of this sensor"
|
|
::= { sensorEntry 60 }
|
|
|
|
sensorOffColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Off Color of this sensor"
|
|
::= { sensorEntry 61 }
|
|
--/* End of sensorEntry */
|
|
|
|
--/* Begin of sensorTemperatureEntry */
|
|
sensorTemperatureTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorTemperatureEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the property and reading value for every Temperature sensor."
|
|
::= { secSensor 2 }
|
|
|
|
sensorTemperatureEntry OBJECT-TYPE
|
|
SYNTAX SensorTemperatureEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorTemperatureEntry Table"
|
|
INDEX { sensorTemperatureIndex }
|
|
::= { sensorTemperatureTable 1 }
|
|
|
|
SensorTemperatureEntry ::= SEQUENCE {
|
|
sensorTemperatureIndex
|
|
INTEGER,
|
|
sensorTemperatureDescription
|
|
DisplayString,
|
|
sensorTemperatureType
|
|
INTEGER,
|
|
sensorTemperatureDegree
|
|
INTEGER,
|
|
sensorTemperatureUnit
|
|
DisplayString,
|
|
sensorTemperatureStatus
|
|
INTEGER,
|
|
sensorTemperatureGoOffline
|
|
INTEGER,
|
|
sensorTemperatureLowCritical
|
|
INTEGER,
|
|
sensorTemperatureLowWarning
|
|
INTEGER,
|
|
sensorTemperatureHighWarning
|
|
INTEGER,
|
|
sensorTemperatureHighCritical
|
|
INTEGER,
|
|
sensorTemperatureRearm
|
|
INTEGER,
|
|
sensorTemperatureDelayError
|
|
INTEGER,
|
|
sensorTemperatureDelayNormal
|
|
INTEGER,
|
|
sensorTemperatureDelayLowCritical
|
|
INTEGER,
|
|
sensorTemperatureDelayLowWarning
|
|
INTEGER,
|
|
sensorTemperatureDelayHighWarning
|
|
INTEGER,
|
|
sensorTemperatureDelayHighCritical
|
|
INTEGER,
|
|
sensorTemperatureRaw
|
|
INTEGER,
|
|
sensorTemperatureOffset
|
|
INTEGER,
|
|
sensorTemperaturePort
|
|
INTEGER,
|
|
sensorTemperatureSubPort
|
|
INTEGER,
|
|
sensorTemperatureDeviceIndex
|
|
INTEGER,
|
|
sensorTemperatureDisplayStyle
|
|
INTEGER,
|
|
sensorTemperatureHighCriticalDesc
|
|
DisplayString,
|
|
sensorTemperatureLowCriticalDesc
|
|
DisplayString,
|
|
sensorTemperatureNormalDesc
|
|
DisplayString,
|
|
sensorTemperatureLowWarningDesc
|
|
DisplayString,
|
|
sensorTemperatureHighWarningDesc
|
|
DisplayString,
|
|
sensorTemperatureSensorErrorDesc
|
|
DisplayString,
|
|
sensorTemperatureHighCriticalColor
|
|
INTEGER,
|
|
sensorTemperatureLowCriticalColor
|
|
INTEGER,
|
|
sensorTemperatureNormalColor
|
|
INTEGER,
|
|
sensorTemperatureLowWarningColor
|
|
INTEGER,
|
|
sensorTemperatureHighWarningColor
|
|
INTEGER,
|
|
sensorTemperatureSensorErrorColor
|
|
INTEGER
|
|
}
|
|
|
|
sensorTemperatureIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index into the sensor table"
|
|
::= { sensorTemperatureEntry 1 }
|
|
|
|
sensorTemperatureDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor"
|
|
::= { sensorTemperatureEntry 2 }
|
|
|
|
sensorTemperatureType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
temperature(1),
|
|
dualsensor(3),
|
|
thermocouple(20)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enter the type of this Sensor"
|
|
::= { sensorTemperatureEntry 3 }
|
|
|
|
sensorTemperatureDegree OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The degrees in this sensor"
|
|
::= { sensorTemperatureEntry 4 }
|
|
|
|
sensorTemperatureUnit OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit string"
|
|
::= { sensorTemperatureEntry 5 }
|
|
|
|
sensorTemperatureStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highWarning(3),
|
|
highCritical(4),
|
|
lowWarning(5),
|
|
lowCritical(6),
|
|
sensorError(7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor"
|
|
::= { sensorTemperatureEntry 6 }
|
|
|
|
sensorTemperatureGoOffline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To take offline enter a 2"
|
|
::= { sensorTemperatureEntry 8 }
|
|
|
|
sensorTemperatureLowCritical OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How cold this sensor gets before it sends a critical event"
|
|
::= { sensorTemperatureEntry 9 }
|
|
|
|
sensorTemperatureLowWarning OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How cold this sensor gets before it sends a warning"
|
|
::= { sensorTemperatureEntry 10 }
|
|
|
|
sensorTemperatureHighWarning OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How hot this sensor gets before it sends a warning"
|
|
::= { sensorTemperatureEntry 11 }
|
|
|
|
sensorTemperatureHighCritical OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How hot this sensor gets before it sends a critical event"
|
|
::= { sensorTemperatureEntry 12 }
|
|
|
|
sensorTemperatureRearm OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of degrees to rearm the status. For example if status goes from normal to warning, the temp must go down spTempRearm degrees below warning before the status goes to normal"
|
|
::= { sensorTemperatureEntry 13 }
|
|
|
|
sensorTemperatureDelayError OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time in seconds after the sensor has been in error status before report as an error"
|
|
::= { sensorTemperatureEntry 14 }
|
|
|
|
sensorTemperatureDelayNormal OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time in seconds after the sensor change from error to normal before report as normal"
|
|
::= { sensorTemperatureEntry 15 }
|
|
|
|
sensorTemperatureDelayLowCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Low Critical before accepting new Status."
|
|
::= { sensorTemperatureEntry 16 }
|
|
|
|
sensorTemperatureDelayLowWarning OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Low Warning before accepting new Status."
|
|
::= { sensorTemperatureEntry 17 }
|
|
|
|
sensorTemperatureDelayHighWarning OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in High Warning before accepting new Status."
|
|
::= { sensorTemperatureEntry 18 }
|
|
|
|
sensorTemperatureDelayHighCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in High Critical before accepting new Status."
|
|
::= { sensorTemperatureEntry 19 }
|
|
|
|
sensorTemperatureRaw OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The raw degree data from the temperature sensor, slightly higher resolution"
|
|
::= { sensorTemperatureEntry 20 }
|
|
|
|
sensorTemperatureOffset OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Temperature Offset reading"
|
|
::= { sensorTemperatureEntry 21 }
|
|
|
|
sensorTemperaturePort OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor port"
|
|
::= { sensorTemperatureEntry 35 }
|
|
|
|
sensorTemperatureSubPort OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor sub port"
|
|
::= { sensorTemperatureEntry 36 }
|
|
|
|
sensorTemperatureDeviceIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Device Index of sensor"
|
|
::= { sensorTemperatureEntry 37 }
|
|
|
|
sensorTemperatureDisplayStyle OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
basic(0),
|
|
gauge(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Temperature display style"
|
|
::= { sensorTemperatureEntry 45 }
|
|
|
|
sensorTemperatureHighCriticalDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A HighCritical Description of this sensor"
|
|
::= { sensorTemperatureEntry 46 }
|
|
|
|
sensorTemperatureLowCriticalDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A LowCritical Description of this sensor"
|
|
::= { sensorTemperatureEntry 47 }
|
|
|
|
sensorTemperatureNormalDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Normal Description of this sensor"
|
|
::= { sensorTemperatureEntry 48 }
|
|
|
|
sensorTemperatureLowWarningDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A LowWarning Description of this sensor"
|
|
::= { sensorTemperatureEntry 49 }
|
|
|
|
sensorTemperatureHighWarningDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A HighWarning Description of this sensor"
|
|
::= { sensorTemperatureEntry 50 }
|
|
|
|
sensorTemperatureSensorErrorDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A SensorError Description of this sensor"
|
|
::= { sensorTemperatureEntry 51 }
|
|
|
|
sensorTemperatureHighCriticalColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A HighCritical Color of this sensor"
|
|
::= { sensorTemperatureEntry 54 }
|
|
|
|
sensorTemperatureLowCriticalColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A LowCritical Color of this sensor"
|
|
::= { sensorTemperatureEntry 55 }
|
|
|
|
sensorTemperatureNormalColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Normal Color of this sensor"
|
|
::= { sensorTemperatureEntry 56 }
|
|
|
|
sensorTemperatureLowWarningColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A LowWarning Color of this sensor"
|
|
::= { sensorTemperatureEntry 57 }
|
|
|
|
sensorTemperatureHighWarningColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A HighWarning Color of this sensor"
|
|
::= { sensorTemperatureEntry 58 }
|
|
|
|
sensorTemperatureSensorErrorColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A SensorError Color of this sensor"
|
|
::= { sensorTemperatureEntry 59 }
|
|
|
|
--/* End of sensorTemperatureEntry */
|
|
|
|
--/* Begin of sensorHumidityEntry */
|
|
sensorHumidityTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorHumidityEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the property and reading value for every sensor."
|
|
::= { secSensor 3 }
|
|
|
|
sensorHumidityEntry OBJECT-TYPE
|
|
SYNTAX SensorHumidityEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorTemperatureEntry Table"
|
|
INDEX { sensorHumidityIndex }
|
|
::= { sensorHumidityTable 1 }
|
|
|
|
SensorHumidityEntry ::= SEQUENCE {
|
|
sensorHumidityIndex
|
|
INTEGER,
|
|
sensorHumidityDescription
|
|
DisplayString,
|
|
sensorHumidityPercent
|
|
INTEGER,
|
|
sensorHumidityUnit
|
|
DisplayString,
|
|
sensorHumidityStatus
|
|
INTEGER,
|
|
sensorHumidityGoOffline
|
|
INTEGER,
|
|
sensorHumidityLowCritical
|
|
INTEGER,
|
|
sensorHumidityLowWarning
|
|
INTEGER,
|
|
sensorHumidityHighWarning
|
|
INTEGER,
|
|
sensorHumidityHighCritical
|
|
INTEGER,
|
|
sensorHumidityRearm
|
|
INTEGER,
|
|
sensorHumidityDelayError
|
|
INTEGER,
|
|
sensorHumidityDelayNormal
|
|
INTEGER,
|
|
sensorHumidityDelayLowCritical
|
|
INTEGER,
|
|
sensorHumidityDelayLowWarning
|
|
INTEGER,
|
|
sensorHumidityDelayHighWarning
|
|
INTEGER,
|
|
sensorHumidityDelayHighCritical
|
|
INTEGER,
|
|
sensorHumidityRaw
|
|
INTEGER,
|
|
sensorHumidityOffset
|
|
INTEGER,
|
|
sensorHumidityPort
|
|
INTEGER,
|
|
sensorHumiditySubPort
|
|
INTEGER,
|
|
sensorHumidityDeviceIndex
|
|
INTEGER,
|
|
sensorHumidityDisplayStyle
|
|
INTEGER,
|
|
sensorHumidityHighCriticalDesc
|
|
DisplayString,
|
|
sensorHumidityLowCriticalDesc
|
|
DisplayString,
|
|
sensorHumidityNormalDesc
|
|
DisplayString,
|
|
sensorHumidityLowWarningDesc
|
|
DisplayString,
|
|
sensorHumidityHighWarningDesc
|
|
DisplayString,
|
|
sensorHumiditySensorErrorDesc
|
|
DisplayString,
|
|
sensorHumidityHighCriticalColor
|
|
INTEGER,
|
|
sensorHumidityLowCriticalColor
|
|
INTEGER,
|
|
sensorHumidityNormalColor
|
|
INTEGER,
|
|
sensorHumidityLowWarningColor
|
|
INTEGER,
|
|
sensorHumidityHighWarningColor
|
|
INTEGER,
|
|
sensorHumiditySensorErrorColor
|
|
INTEGER
|
|
}
|
|
|
|
sensorHumidityIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index into the sensor table"
|
|
::= { sensorHumidityEntry 1 }
|
|
|
|
sensorHumidityDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor"
|
|
::= { sensorHumidityEntry 2 }
|
|
|
|
sensorHumidityPercent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The relative humidity percentage measured by this sensor"
|
|
::= { sensorHumidityEntry 4 }
|
|
|
|
sensorHumidityUnit OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit string"
|
|
::= { sensorHumidityEntry 5 }
|
|
|
|
sensorHumidityStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highWarning(3),
|
|
highCritical(4),
|
|
lowWarning(5),
|
|
lowCritical(6),
|
|
sensorError(7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor"
|
|
::= { sensorHumidityEntry 6 }
|
|
|
|
sensorHumidityGoOffline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To take offline enter a 2"
|
|
::= { sensorHumidityEntry 8 }
|
|
|
|
sensorHumidityLowCritical OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How cold this sensor gets before it sends a critical event"
|
|
::= { sensorHumidityEntry 9 }
|
|
|
|
sensorHumidityLowWarning OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How cold this sensor gets before it sends a warning"
|
|
::= { sensorHumidityEntry 10 }
|
|
|
|
sensorHumidityHighWarning OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How hot this sensor gets before it sends a warning"
|
|
::= { sensorHumidityEntry 11 }
|
|
|
|
sensorHumidityHighCritical OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How hot this sensor gets before it sends a critical event"
|
|
::= { sensorHumidityEntry 12 }
|
|
|
|
sensorHumidityRearm OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of degrees to rearm the status. For example if status goes from normal to warning, the temp must go down spTempRearm degrees below warning before the status goes to normal"
|
|
::= { sensorHumidityEntry 13 }
|
|
|
|
sensorHumidityDelayError OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time in seconds after the sensor has been in error status before report as an error"
|
|
::= { sensorHumidityEntry 14 }
|
|
|
|
sensorHumidityDelayNormal OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time in seconds after the sensor change from error to normal before report as normal"
|
|
::= { sensorHumidityEntry 15 }
|
|
|
|
sensorHumidityDelayLowCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Low Critical before accepting new Status."
|
|
::= { sensorHumidityEntry 16 }
|
|
|
|
sensorHumidityDelayLowWarning OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Low Warning before accepting new Status."
|
|
::= { sensorHumidityEntry 17 }
|
|
|
|
sensorHumidityDelayHighWarning OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in High Warning before accepting new Status."
|
|
::= { sensorHumidityEntry 18 }
|
|
|
|
sensorHumidityDelayHighCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in High Critical before accepting new Status."
|
|
::= { sensorHumidityEntry 19 }
|
|
|
|
sensorHumidityRaw OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unformatted, raw, A/D value in this sensor. Contains more resolution than the formated percentage. This number can go from 0 to 1023 depending on the input voltage"
|
|
::= { sensorHumidityEntry 20 }
|
|
|
|
sensorHumidityOffset OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Humidity Offset reading"
|
|
::= { sensorHumidityEntry 21 }
|
|
|
|
sensorHumidityPort OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor port"
|
|
::= { sensorHumidityEntry 35 }
|
|
|
|
sensorHumiditySubPort OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor sub port"
|
|
::= { sensorHumidityEntry 36 }
|
|
|
|
sensorHumidityDeviceIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Device Index of sensor"
|
|
::= { sensorHumidityEntry 37 }
|
|
|
|
sensorHumidityDisplayStyle OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
basic(0),
|
|
gauge(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Humidity display style"
|
|
::= { sensorHumidityEntry 45 }
|
|
|
|
sensorHumidityHighCriticalDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A HighCritical Description of this sensor"
|
|
::= { sensorHumidityEntry 46 }
|
|
|
|
sensorHumidityLowCriticalDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A LowCritical Description of this sensor"
|
|
::= { sensorHumidityEntry 47 }
|
|
|
|
sensorHumidityNormalDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Normal Description of this sensor"
|
|
::= { sensorHumidityEntry 48 }
|
|
|
|
sensorHumidityLowWarningDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A LowWarning Description of this sensor"
|
|
::= { sensorHumidityEntry 49 }
|
|
|
|
sensorHumidityHighWarningDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A HighWarning Description of this sensor"
|
|
::= { sensorHumidityEntry 50 }
|
|
|
|
sensorHumiditySensorErrorDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A SensorError Description of this sensor"
|
|
::= { sensorHumidityEntry 51 }
|
|
|
|
sensorHumidityHighCriticalColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A HighCritical Color of this sensor"
|
|
::= { sensorHumidityEntry 54 }
|
|
|
|
sensorHumidityLowCriticalColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A LowCritical Color of this sensor"
|
|
::= { sensorHumidityEntry 55 }
|
|
|
|
sensorHumidityNormalColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Normal Color of this sensor"
|
|
::= { sensorHumidityEntry 56 }
|
|
|
|
sensorHumidityLowWarningColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A LowWarning Color of this sensor"
|
|
::= { sensorHumidityEntry 57 }
|
|
|
|
sensorHumidityHighWarningColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A HighWarning Color of this sensor"
|
|
::= { sensorHumidityEntry 58 }
|
|
|
|
sensorHumiditySensorErrorColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A SensorError Color of this sensor"
|
|
::= { sensorHumidityEntry 59 }
|
|
|
|
--/* End of sensorHumidityEntry */
|
|
|
|
--/* Begin of sensorDryContactEntry */
|
|
sensorDryContactTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorDryContactEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the property and reading value for every sensor."
|
|
::= { secSensor 4 }
|
|
|
|
sensorDryContactEntry OBJECT-TYPE
|
|
SYNTAX SensorDryContactEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorTemperatureEntry Table"
|
|
INDEX { sensorDryContactIndex }
|
|
::= { sensorDryContactTable 1 }
|
|
|
|
SensorDryContactEntry ::= SEQUENCE {
|
|
sensorDryContactIndex
|
|
INTEGER,
|
|
sensorDryContactDescription
|
|
DisplayString,
|
|
sensorDryContactType
|
|
INTEGER,
|
|
sensorDryContactStatus
|
|
INTEGER,
|
|
sensorDryContactGoOffline
|
|
INTEGER,
|
|
sensorDryContactDirection
|
|
INTEGER,
|
|
sensorDryContactNormalState
|
|
INTEGER,
|
|
sensorDryContactControlMode
|
|
INTEGER,
|
|
sensorDryContactOutputManualCycleTime
|
|
INTEGER,
|
|
sensorDryContactOutputManualAction
|
|
INTEGER,
|
|
sensorDryContactPort
|
|
INTEGER,
|
|
sensorDryContactSubPort
|
|
INTEGER,
|
|
sensorDryContactDeviceIndex
|
|
INTEGER,
|
|
sensorDryContactCriticalDesc
|
|
DisplayString,
|
|
sensorDryContactNormalDesc
|
|
DisplayString,
|
|
sensorDryContactOnDesc
|
|
DisplayString,
|
|
sensorDryContactOffDesc
|
|
DisplayString,
|
|
sensorDryContactCriticalColor
|
|
INTEGER,
|
|
sensorDryContactNormalColor
|
|
INTEGER,
|
|
sensorDryContactOnColor
|
|
INTEGER,
|
|
sensorDryContactOffColor
|
|
INTEGER
|
|
}
|
|
|
|
sensorDryContactIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index into the Switch sensor table"
|
|
::= { sensorDryContactEntry 1 }
|
|
|
|
sensorDryContactDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor Switch"
|
|
::= { sensorDryContactEntry 2 }
|
|
|
|
sensorDryContactType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
drycontact-inout(7),
|
|
drycontact-input(8),
|
|
drycontact-array(22)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enter the type of this Sensor"
|
|
::= { sensorDryContactEntry 3 }
|
|
|
|
sensorDryContactStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highCritical(4),
|
|
lowCritical(6),
|
|
sensorError(7),
|
|
outputLow(8),
|
|
outputHigh(9)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor, only input switches have a status"
|
|
::= { sensorDryContactEntry 6 }
|
|
|
|
sensorDryContactGoOffline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To take offline enter a 2"
|
|
::= { sensorDryContactEntry 8 }
|
|
|
|
sensorDryContactDirection OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
input(0),
|
|
output(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To set a switch to input enter 0. To set a switch to output enter 1"
|
|
::= { sensorDryContactEntry 22 }
|
|
|
|
sensorDryContactNormalState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
closed(0),
|
|
open(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The normal state of an input switch. If an input switch is in this state it is normal, else it is critical. An open switch senses +5 volts. A closed switch senses 0 volts."
|
|
::= { sensorDryContactEntry 23 }
|
|
|
|
sensorDryContactControlMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
manual-control(0),
|
|
sensor-control(1),
|
|
time-control(2),
|
|
thermostat-control(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Control Mode used for selecting the mode to control a sensor output."
|
|
::= { sensorDryContactEntry 24 }
|
|
|
|
sensorDryContactOutputManualCycleTime OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Toggle period in seconds for Manual Cycle action."
|
|
::= { sensorDryContactEntry 25 }
|
|
|
|
sensorDryContactOutputManualAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
low(0),
|
|
high(1),
|
|
cycle-Low-High-Low(2),
|
|
cycle-High-Low-High(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Control the sensor output manualy"
|
|
::= { sensorDryContactEntry 26 }
|
|
|
|
sensorDryContactPort OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor port"
|
|
::= { sensorDryContactEntry 35 }
|
|
|
|
sensorDryContactSubPort OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor sub port"
|
|
::= { sensorDryContactEntry 36 }
|
|
|
|
sensorDryContactDeviceIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Device Index of sensor"
|
|
::= { sensorDryContactEntry 37 }
|
|
|
|
sensorDryContactCriticalDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Critical Description of this sensor"
|
|
::= { sensorDryContactEntry 46 }
|
|
|
|
sensorDryContactNormalDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Normal Description of this sensor"
|
|
::= { sensorDryContactEntry 48 }
|
|
|
|
sensorDryContactOnDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A On Description of this sensor"
|
|
::= { sensorDryContactEntry 52 }
|
|
|
|
sensorDryContactOffDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Off Description of this sensor"
|
|
::= { sensorDryContactEntry 53 }
|
|
|
|
sensorDryContactCriticalColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Critical Color of this sensor"
|
|
::= { sensorDryContactEntry 54 }
|
|
|
|
sensorDryContactNormalColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Normal Color of this sensor"
|
|
::= { sensorDryContactEntry 56 }
|
|
|
|
sensorDryContactOnColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A On Color of this sensor"
|
|
::= { sensorDryContactEntry 60 }
|
|
|
|
sensorDryContactOffColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Off Color of this sensor"
|
|
::= { sensorDryContactEntry 61 }
|
|
|
|
--/* End of sensorDryContactEntry */
|
|
|
|
--/* Begin of sensor4to20mAEntry */
|
|
sensor4to20mATable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Sensor4to20mAEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the property and reading value for every sensor."
|
|
::= { secSensor 5 }
|
|
|
|
sensor4to20mAEntry OBJECT-TYPE
|
|
SYNTAX Sensor4to20mAEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorTemperatureEntry Table"
|
|
INDEX { sensor4to20mAIndex }
|
|
::= { sensor4to20mATable 1 }
|
|
|
|
Sensor4to20mAEntry ::= SEQUENCE {
|
|
sensor4to20mAIndex
|
|
INTEGER,
|
|
sensor4to20mADescription
|
|
DisplayString,
|
|
sensor4to20mAValue
|
|
INTEGER,
|
|
sensor4to20mAUnit
|
|
DisplayString,
|
|
sensor4to20mAStatus
|
|
INTEGER,
|
|
sensor4to20mAGoOffline
|
|
INTEGER,
|
|
sensor4to20mALowCritical
|
|
INTEGER,
|
|
sensor4to20mALowWarning
|
|
INTEGER,
|
|
sensor4to20mAHighWarning
|
|
INTEGER,
|
|
sensor4to20mAHighCritical
|
|
INTEGER,
|
|
sensor4to20mARearm
|
|
INTEGER,
|
|
sensor4to20mADelayError
|
|
INTEGER,
|
|
sensor4to20mADelayNormal
|
|
INTEGER,
|
|
sensor4to20mADelayLowCritical
|
|
INTEGER,
|
|
sensor4to20mADelayLowWarning
|
|
INTEGER,
|
|
sensor4to20mADelayHighWarning
|
|
INTEGER,
|
|
sensor4to20mADelayHighCritical
|
|
INTEGER,
|
|
sensor4to20mARaw
|
|
INTEGER,
|
|
sensor4to20mAOffset
|
|
INTEGER,
|
|
sensor4to20mAAmountMaxVoltage
|
|
INTEGER,
|
|
sensor4to20mAAmountBaseVoltage
|
|
INTEGER,
|
|
sensor4to20mAPort
|
|
INTEGER,
|
|
sensor4to20mASubPort
|
|
INTEGER,
|
|
sensor4to20mADeviceIndex
|
|
INTEGER,
|
|
sensor4to20mAMaxVoltage
|
|
INTEGER,
|
|
sensor4to20mABaseVoltage
|
|
INTEGER,
|
|
sensor4to20mADisplayStyle
|
|
INTEGER,
|
|
sensor4to20mAHighCriticalDesc
|
|
DisplayString,
|
|
sensor4to20mALowCriticalDesc
|
|
DisplayString,
|
|
sensor4to20mANormalDesc
|
|
DisplayString,
|
|
sensor4to20mALowWarningDesc
|
|
DisplayString,
|
|
sensor4to20mAHighWarningDesc
|
|
DisplayString,
|
|
sensor4to20mASensorErrorDesc
|
|
DisplayString,
|
|
sensor4to20mAHighCriticalColor
|
|
INTEGER,
|
|
sensor4to20mALowCriticalColor
|
|
INTEGER,
|
|
sensor4to20mANormalColor
|
|
INTEGER,
|
|
sensor4to20mALowWarningColor
|
|
INTEGER,
|
|
sensor4to20mAHighWarningColor
|
|
INTEGER,
|
|
sensor4to20mASensorErrorColor
|
|
INTEGER
|
|
}
|
|
|
|
sensor4to20mAIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index into the sensor table"
|
|
::= { sensor4to20mAEntry 1 }
|
|
|
|
sensor4to20mADescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor"
|
|
::= { sensor4to20mAEntry 2 }
|
|
|
|
sensor4to20mAValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The reading value in this sensor"
|
|
::= { sensor4to20mAEntry 4 }
|
|
|
|
sensor4to20mAUnit OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit string"
|
|
::= { sensor4to20mAEntry 5 }
|
|
|
|
sensor4to20mAStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highWarning(3),
|
|
highCritical(4),
|
|
lowWarning(5),
|
|
lowCritical(6),
|
|
sensorError(7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor"
|
|
::= { sensor4to20mAEntry 6 }
|
|
|
|
sensor4to20mAGoOffline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To take offline enter a 2"
|
|
::= { sensor4to20mAEntry 8 }
|
|
|
|
sensor4to20mALowCritical OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How cold this sensor gets before it sends a critical event"
|
|
::= { sensor4to20mAEntry 9 }
|
|
|
|
sensor4to20mALowWarning OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How cold this sensor gets before it sends a warning"
|
|
::= { sensor4to20mAEntry 10 }
|
|
|
|
sensor4to20mAHighWarning OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How hot this sensor gets before it sends a warning"
|
|
::= { sensor4to20mAEntry 11 }
|
|
|
|
sensor4to20mAHighCritical OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How hot this sensor gets before it sends a critical event"
|
|
::= { sensor4to20mAEntry 12 }
|
|
|
|
sensor4to20mARearm OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of degrees to rearm the status. For example if status goes from normal to warning, the temp must go down spTempRearm degrees below warning before the status goes to normal"
|
|
::= { sensor4to20mAEntry 13 }
|
|
|
|
sensor4to20mADelayError OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time in seconds after the sensor has been in error status before report as an error"
|
|
::= { sensor4to20mAEntry 14 }
|
|
|
|
sensor4to20mADelayNormal OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time in seconds after the sensor change from error to normal before report as normal"
|
|
::= { sensor4to20mAEntry 15 }
|
|
|
|
sensor4to20mADelayLowCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Low Critical before accepting new Status."
|
|
::= { sensor4to20mAEntry 16 }
|
|
|
|
sensor4to20mADelayLowWarning OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Low Warning before accepting new Status."
|
|
::= { sensor4to20mAEntry 17 }
|
|
|
|
sensor4to20mADelayHighWarning OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in High Warning before accepting new Status."
|
|
::= { sensor4to20mAEntry 18 }
|
|
|
|
sensor4to20mADelayHighCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in High Critical before accepting new Status."
|
|
::= { sensor4to20mAEntry 19 }
|
|
|
|
sensor4to20mARaw OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unformatted, raw, A/D value in this sensor. Contains more resolution than the formated percentage. This number can go from 0 to 1023 depending on the input voltage"
|
|
::= { sensor4to20mAEntry 20 }
|
|
|
|
sensor4to20mAOffset OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"4to20mA Offset reading"
|
|
::= { sensor4to20mAEntry 21 }
|
|
|
|
sensor4to20mAAmountMaxVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum scale of 4to20mA conversion."
|
|
::= { sensor4to20mAEntry 33 }
|
|
|
|
sensor4to20mAAmountBaseVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The base scale of 4to20mA conversion."
|
|
::= { sensor4to20mAEntry 34 }
|
|
|
|
sensor4to20mAPort OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor port"
|
|
::= { sensor4to20mAEntry 35 }
|
|
|
|
sensor4to20mASubPort OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor sub port"
|
|
::= { sensor4to20mAEntry 36 }
|
|
|
|
sensor4to20mADeviceIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Device Index of sensor"
|
|
::= { sensor4to20mAEntry 37 }
|
|
|
|
sensor4to20mAMaxVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The max range for use in conversion."
|
|
::= { sensor4to20mAEntry 43 }
|
|
|
|
sensor4to20mABaseVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The base range for use in conversion."
|
|
::= { sensor4to20mAEntry 44 }
|
|
|
|
sensor4to20mADisplayStyle OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
basic(0),
|
|
gauge(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"4to20mA display style"
|
|
::= { sensor4to20mAEntry 45 }
|
|
|
|
sensor4to20mAHighCriticalDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A HighCritical Description of this sensor"
|
|
::= { sensor4to20mAEntry 46 }
|
|
|
|
sensor4to20mALowCriticalDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A LowCritical Description of this sensor"
|
|
::= { sensor4to20mAEntry 47 }
|
|
|
|
sensor4to20mANormalDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Normal Description of this sensor"
|
|
::= { sensor4to20mAEntry 48 }
|
|
|
|
sensor4to20mALowWarningDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A LowWarning Description of this sensor"
|
|
::= { sensor4to20mAEntry 49 }
|
|
|
|
sensor4to20mAHighWarningDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A HighWarning Description of this sensor"
|
|
::= { sensor4to20mAEntry 50 }
|
|
|
|
sensor4to20mASensorErrorDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A SensorError Description of this sensor"
|
|
::= { sensor4to20mAEntry 51 }
|
|
|
|
sensor4to20mAHighCriticalColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A HighCritical Color of this sensor"
|
|
::= { sensor4to20mAEntry 54 }
|
|
|
|
sensor4to20mALowCriticalColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A LowCritical Color of this sensor"
|
|
::= { sensor4to20mAEntry 55 }
|
|
|
|
sensor4to20mANormalColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Normal Color of this sensor"
|
|
::= { sensor4to20mAEntry 56 }
|
|
|
|
sensor4to20mALowWarningColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A LowWarning Color of this sensor"
|
|
::= { sensor4to20mAEntry 57 }
|
|
|
|
sensor4to20mAHighWarningColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A HighWarning Color of this sensor"
|
|
::= { sensor4to20mAEntry 58 }
|
|
|
|
sensor4to20mASensorErrorColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A SensorError Color of this sensor"
|
|
::= { sensor4to20mAEntry 59 }
|
|
|
|
--/* End of sensor4to20mAEntry */
|
|
|
|
--/* Begin of sensorDCvoltageEntry */
|
|
sensorDCvoltageTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorDCvoltageEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the property and reading value for every sensor."
|
|
::= { secSensor 6 }
|
|
|
|
sensorDCvoltageEntry OBJECT-TYPE
|
|
SYNTAX SensorDCvoltageEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorTemperatureEntry Table"
|
|
INDEX { sensorDCvoltageIndex }
|
|
::= { sensorDCvoltageTable 1 }
|
|
|
|
SensorDCvoltageEntry ::= SEQUENCE {
|
|
sensorDCvoltageIndex
|
|
INTEGER,
|
|
sensorDCvoltageDescription
|
|
DisplayString,
|
|
sensorDCvoltageValue
|
|
INTEGER,
|
|
sensorDCvoltageUnit
|
|
DisplayString,
|
|
sensorDCvoltageStatus
|
|
INTEGER,
|
|
sensorDCvoltageGoOffline
|
|
INTEGER,
|
|
sensorDCvoltageLowCritical
|
|
INTEGER,
|
|
sensorDCvoltageLowWarning
|
|
INTEGER,
|
|
sensorDCvoltageHighWarning
|
|
INTEGER,
|
|
sensorDCvoltageHighCritical
|
|
INTEGER,
|
|
sensorDCvoltageRearm
|
|
INTEGER,
|
|
sensorDCvoltageDelayError
|
|
INTEGER,
|
|
sensorDCvoltageDelayNormal
|
|
INTEGER,
|
|
sensorDCvoltageDelayLowCritical
|
|
INTEGER,
|
|
sensorDCvoltageDelayLowWarning
|
|
INTEGER,
|
|
sensorDCvoltageDelayHighWarning
|
|
INTEGER,
|
|
sensorDCvoltageDelayHighCritical
|
|
INTEGER,
|
|
sensorDCvoltageRaw
|
|
INTEGER,
|
|
sensorDCvoltageOffset
|
|
INTEGER,
|
|
sensorDCvoltageJumper
|
|
INTEGER,
|
|
sensorDCvoltageAmountMaxVoltage
|
|
INTEGER,
|
|
sensorDCvoltageAmountBaseVoltage
|
|
INTEGER,
|
|
sensorDCvoltagePort
|
|
INTEGER,
|
|
sensorDCvoltageSubPort
|
|
INTEGER,
|
|
sensorDCvoltageDeviceIndex
|
|
INTEGER,
|
|
sensorDCvoltageMaxVoltage
|
|
INTEGER,
|
|
sensorDCvoltageBaseVoltage
|
|
INTEGER,
|
|
sensorDCvoltageDisplayStyle
|
|
INTEGER,
|
|
sensorDCvoltageHighCriticalDesc
|
|
DisplayString,
|
|
sensorDCvoltageLowCriticalDesc
|
|
DisplayString,
|
|
sensorDCvoltageNormalDesc
|
|
DisplayString,
|
|
sensorDCvoltageLowWarningDesc
|
|
DisplayString,
|
|
sensorDCvoltageHighWarningDesc
|
|
DisplayString,
|
|
sensorDCvoltageSensorErrorDesc
|
|
DisplayString,
|
|
sensorDCvoltageHighCriticalColor
|
|
INTEGER,
|
|
sensorDCvoltageLowCriticalColor
|
|
INTEGER,
|
|
sensorDCvoltageNormalColor
|
|
INTEGER,
|
|
sensorDCvoltageLowWarningColor
|
|
INTEGER,
|
|
sensorDCvoltageHighWarningColor
|
|
INTEGER,
|
|
sensorDCvoltageSensorErrorColor
|
|
INTEGER
|
|
}
|
|
|
|
sensorDCvoltageIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index into the sensor table"
|
|
::= { sensorDCvoltageEntry 1 }
|
|
|
|
sensorDCvoltageDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor"
|
|
::= { sensorDCvoltageEntry 2 }
|
|
|
|
sensorDCvoltageValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The reading value in this sensor"
|
|
::= { sensorDCvoltageEntry 4 }
|
|
|
|
sensorDCvoltageUnit OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit string"
|
|
::= { sensorDCvoltageEntry 5 }
|
|
|
|
sensorDCvoltageStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highWarning(3),
|
|
highCritical(4),
|
|
lowWarning(5),
|
|
lowCritical(6),
|
|
sensorError(7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor"
|
|
::= { sensorDCvoltageEntry 6 }
|
|
|
|
sensorDCvoltageGoOffline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To take offline enter a 2"
|
|
::= { sensorDCvoltageEntry 8 }
|
|
|
|
sensorDCvoltageLowCritical OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How cold this sensor gets before it sends a critical event"
|
|
::= { sensorDCvoltageEntry 9 }
|
|
|
|
sensorDCvoltageLowWarning OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How cold this sensor gets before it sends a warning"
|
|
::= { sensorDCvoltageEntry 10 }
|
|
|
|
sensorDCvoltageHighWarning OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How hot this sensor gets before it sends a warning"
|
|
::= { sensorDCvoltageEntry 11 }
|
|
|
|
sensorDCvoltageHighCritical OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How hot this sensor gets before it sends a critical event"
|
|
::= { sensorDCvoltageEntry 12 }
|
|
|
|
sensorDCvoltageRearm OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of degrees to rearm the status. For example if status goes from normal to warning, the temp must go down spTempRearm degrees below warning before the status goes to normal"
|
|
::= { sensorDCvoltageEntry 13 }
|
|
|
|
sensorDCvoltageDelayError OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time in seconds after the sensor has been in error status before report as an error"
|
|
::= { sensorDCvoltageEntry 14 }
|
|
|
|
sensorDCvoltageDelayNormal OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time in seconds after the sensor change from error to normal before report as normal"
|
|
::= { sensorDCvoltageEntry 15 }
|
|
|
|
sensorDCvoltageDelayLowCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Low Critical before accepting new Status."
|
|
::= { sensorDCvoltageEntry 16 }
|
|
|
|
sensorDCvoltageDelayLowWarning OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Low Warning before accepting new Status."
|
|
::= { sensorDCvoltageEntry 17 }
|
|
|
|
sensorDCvoltageDelayHighWarning OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in High Warning before accepting new Status."
|
|
::= { sensorDCvoltageEntry 18 }
|
|
|
|
sensorDCvoltageDelayHighCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in High Critical before accepting new Status."
|
|
::= { sensorDCvoltageEntry 19 }
|
|
|
|
sensorDCvoltageRaw OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unformatted, raw, A/D value in this sensor. Contains more resolution than the formated percentage. This number can go from 0 to 1023 depending on the input voltage"
|
|
::= { sensorDCvoltageEntry 20 }
|
|
|
|
sensorDCvoltageOffset OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"DC voltage Offset reading"
|
|
::= { sensorDCvoltageEntry 21 }
|
|
|
|
sensorDCvoltageJumper OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
jumperAt-60(-600),
|
|
jumperAt-40(-400),
|
|
jumperAt-30(-300),
|
|
jumperAt-20(-200),
|
|
jumperAt-10(-100),
|
|
jumperAt10(100),
|
|
jumperAt20(200),
|
|
jumperAt30(300),
|
|
jumperAt40(400),
|
|
jumperAt60(600)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selected voltage scale (jumper 0) in DC voltage conversion."
|
|
::= { sensorDCvoltageEntry 32 }
|
|
|
|
sensorDCvoltageAmountMaxVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum scale of DC voltage conversion."
|
|
::= { sensorDCvoltageEntry 33 }
|
|
|
|
sensorDCvoltageAmountBaseVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The base scale of DC voltage conversion."
|
|
::= { sensorDCvoltageEntry 34 }
|
|
|
|
sensorDCvoltagePort OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor port"
|
|
::= { sensorDCvoltageEntry 35 }
|
|
|
|
sensorDCvoltageSubPort OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor sub port"
|
|
::= { sensorDCvoltageEntry 36 }
|
|
|
|
sensorDCvoltageDeviceIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Device Index of sensor"
|
|
::= { sensorDCvoltageEntry 37 }
|
|
|
|
sensorDCvoltageMaxVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The max voltage range for use in conversion."
|
|
::= { sensorDCvoltageEntry 43 }
|
|
|
|
sensorDCvoltageBaseVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The base voltage range for use in conversion."
|
|
::= { sensorDCvoltageEntry 44 }
|
|
|
|
sensorDCvoltageDisplayStyle OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
basic(0),
|
|
gauge(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"DCVoltage display style"
|
|
::= { sensorDCvoltageEntry 45 }
|
|
|
|
sensorDCvoltageHighCriticalDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A HighCritical Description of this sensor"
|
|
::= { sensorDCvoltageEntry 46 }
|
|
|
|
sensorDCvoltageLowCriticalDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A LowCritical Description of this sensor"
|
|
::= { sensorDCvoltageEntry 47 }
|
|
|
|
sensorDCvoltageNormalDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Normal Description of this sensor"
|
|
::= { sensorDCvoltageEntry 48 }
|
|
|
|
sensorDCvoltageLowWarningDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A LowWarning Description of this sensor"
|
|
::= { sensorDCvoltageEntry 49 }
|
|
|
|
sensorDCvoltageHighWarningDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A HighWarning Description of this sensor"
|
|
::= { sensorDCvoltageEntry 50 }
|
|
|
|
sensorDCvoltageSensorErrorDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A SensorError Description of this sensor"
|
|
::= { sensorDCvoltageEntry 51 }
|
|
|
|
sensorDCvoltageHighCriticalColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A HighCritical Color of this sensor"
|
|
::= { sensorDCvoltageEntry 54 }
|
|
|
|
sensorDCvoltageLowCriticalColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A LowCritical Color of this sensor"
|
|
::= { sensorDCvoltageEntry 55 }
|
|
|
|
sensorDCvoltageNormalColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Normal Color of this sensor"
|
|
::= { sensorDCvoltageEntry 56 }
|
|
|
|
sensorDCvoltageLowWarningColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A LowWarning Color of this sensor"
|
|
::= { sensorDCvoltageEntry 57 }
|
|
|
|
sensorDCvoltageHighWarningColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A HighWarning Color of this sensor"
|
|
::= { sensorDCvoltageEntry 58 }
|
|
|
|
sensorDCvoltageSensorErrorColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A SensorError Color of this sensor"
|
|
::= { sensorDCvoltageEntry 59 }
|
|
|
|
--/* End of sensorDCvoltageEntry */
|
|
|
|
--/* Begin of sensorAirflowEntry */
|
|
sensorAirflowTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorAirflowEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the property and reading value for every sensor."
|
|
::= { secSensor 7 }
|
|
|
|
sensorAirflowEntry OBJECT-TYPE
|
|
SYNTAX SensorAirflowEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorTemperatureEntry Table"
|
|
INDEX { sensorAirflowIndex }
|
|
::= { sensorAirflowTable 1 }
|
|
|
|
SensorAirflowEntry ::= SEQUENCE {
|
|
sensorAirflowIndex
|
|
INTEGER,
|
|
sensorAirflowDescription
|
|
DisplayString,
|
|
sensorAirflowValue
|
|
INTEGER,
|
|
sensorAirflowStatus
|
|
INTEGER,
|
|
sensorAirflowGoOffline
|
|
INTEGER,
|
|
sensorAirflowLowCritical
|
|
INTEGER,
|
|
sensorAirflowLowWarning
|
|
INTEGER,
|
|
sensorAirflowHighWarning
|
|
INTEGER,
|
|
sensorAirflowHighCritical
|
|
INTEGER,
|
|
sensorAirflowRearm
|
|
INTEGER,
|
|
sensorAirflowDelayError
|
|
INTEGER,
|
|
sensorAirflowDelayNormal
|
|
INTEGER,
|
|
sensorAirflowDelayLowCritical
|
|
INTEGER,
|
|
sensorAirflowDelayLowWarning
|
|
INTEGER,
|
|
sensorAirflowDelayHighWarning
|
|
INTEGER,
|
|
sensorAirflowDelayHighCritical
|
|
INTEGER,
|
|
sensorAirflowRaw
|
|
INTEGER,
|
|
sensorAirflowPort
|
|
INTEGER,
|
|
sensorAirflowSubPort
|
|
INTEGER,
|
|
sensorAirflowDeviceIndex
|
|
INTEGER,
|
|
sensorAirflowDisplayStyle
|
|
INTEGER,
|
|
sensorAirflowHighCriticalDesc
|
|
DisplayString,
|
|
sensorAirflowLowCriticalDesc
|
|
DisplayString,
|
|
sensorAirflowNormalDesc
|
|
DisplayString,
|
|
sensorAirflowLowWarningDesc
|
|
DisplayString,
|
|
sensorAirflowHighWarningDesc
|
|
DisplayString,
|
|
sensorAirflowSensorErrorDesc
|
|
DisplayString,
|
|
sensorAirflowHighCriticalColor
|
|
INTEGER,
|
|
sensorAirflowLowCriticalColor
|
|
INTEGER,
|
|
sensorAirflowNormalColor
|
|
INTEGER,
|
|
sensorAirflowLowWarningColor
|
|
INTEGER,
|
|
sensorAirflowHighWarningColor
|
|
INTEGER,
|
|
sensorAirflowSensorErrorColor
|
|
INTEGER
|
|
}
|
|
|
|
sensorAirflowIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index into the Switch sensor table"
|
|
::= { sensorAirflowEntry 1 }
|
|
|
|
sensorAirflowDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor Switch"
|
|
::= { sensorAirflowEntry 2 }
|
|
|
|
sensorAirflowValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The reading value in this sensor"
|
|
::= { sensorAirflowEntry 4 }
|
|
|
|
sensorAirflowStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highCritical(4),
|
|
lowCritical(6),
|
|
sensorError(7),
|
|
relayOn(8),
|
|
relayOff(9)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor, only input switches have a status"
|
|
::= { sensorAirflowEntry 6 }
|
|
|
|
sensorAirflowGoOffline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To take offline enter a 2"
|
|
::= { sensorAirflowEntry 8 }
|
|
|
|
sensorAirflowLowCritical OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How cold this sensor gets before it sends a critical event"
|
|
::= { sensorAirflowEntry 9 }
|
|
|
|
sensorAirflowLowWarning OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How cold this sensor gets before it sends a warning"
|
|
::= { sensorAirflowEntry 10 }
|
|
|
|
sensorAirflowHighWarning OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How hot this sensor gets before it sends a warning"
|
|
::= { sensorAirflowEntry 11 }
|
|
|
|
sensorAirflowHighCritical OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How hot this sensor gets before it sends a critical event"
|
|
::= { sensorAirflowEntry 12 }
|
|
|
|
sensorAirflowRearm OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of degrees to rearm the status. For example if status goes from normal to warning, the temp must go down spTempRearm degrees below warning before the status goes to normal"
|
|
::= { sensorAirflowEntry 13 }
|
|
|
|
sensorAirflowDelayError OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time in seconds after the sensor has been in error status before report as an error"
|
|
::= { sensorAirflowEntry 14 }
|
|
|
|
sensorAirflowDelayNormal OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time in seconds after the sensor change from error to normal before report as normal"
|
|
::= { sensorAirflowEntry 15 }
|
|
|
|
sensorAirflowDelayLowCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Low Critical before accepting new Status."
|
|
::= { sensorAirflowEntry 16 }
|
|
|
|
sensorAirflowDelayLowWarning OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Low Warning before accepting new Status."
|
|
::= { sensorAirflowEntry 17 }
|
|
|
|
sensorAirflowDelayHighWarning OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in High Warning before accepting new Status."
|
|
::= { sensorAirflowEntry 18 }
|
|
|
|
sensorAirflowDelayHighCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in High Critical before accepting new Status."
|
|
::= { sensorAirflowEntry 19 }
|
|
|
|
sensorAirflowRaw OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unformatted, raw, A/D value in this sensor. Contains more resolution than the formated percentage. This number can go from 0 to 1023 depending on the input voltage"
|
|
::= { sensorAirflowEntry 20 }
|
|
|
|
sensorAirflowPort OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor port"
|
|
::= { sensorAirflowEntry 35 }
|
|
|
|
sensorAirflowSubPort OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor sub port"
|
|
::= { sensorAirflowEntry 36 }
|
|
|
|
sensorAirflowDeviceIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Device Index of sensor"
|
|
::= { sensorAirflowEntry 37 }
|
|
|
|
sensorAirflowDisplayStyle OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
basic(0),
|
|
gauge(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Airflow display style"
|
|
::= { sensorAirflowEntry 45 }
|
|
|
|
sensorAirflowHighCriticalDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A HighCritical Description of this sensor"
|
|
::= { sensorAirflowEntry 46 }
|
|
|
|
sensorAirflowLowCriticalDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A LowCritical Description of this sensor"
|
|
::= { sensorAirflowEntry 47 }
|
|
|
|
sensorAirflowNormalDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Normal Description of this sensor"
|
|
::= { sensorAirflowEntry 48 }
|
|
|
|
sensorAirflowLowWarningDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A LowWarning Description of this sensor"
|
|
::= { sensorAirflowEntry 49 }
|
|
|
|
sensorAirflowHighWarningDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A HighWarning Description of this sensor"
|
|
::= { sensorAirflowEntry 50 }
|
|
|
|
sensorAirflowSensorErrorDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A SensorError Description of this sensor"
|
|
::= { sensorAirflowEntry 51 }
|
|
|
|
sensorAirflowHighCriticalColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A HighCritical Color of this sensor"
|
|
::= { sensorAirflowEntry 54 }
|
|
|
|
sensorAirflowLowCriticalColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A LowCritical Color of this sensor"
|
|
::= { sensorAirflowEntry 55 }
|
|
|
|
sensorAirflowNormalColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Normal Color of this sensor"
|
|
::= { sensorAirflowEntry 56 }
|
|
|
|
sensorAirflowLowWarningColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A LowWarning Color of this sensor"
|
|
::= { sensorAirflowEntry 57 }
|
|
|
|
sensorAirflowHighWarningColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A HighWarning Color of this sensor"
|
|
::= { sensorAirflowEntry 58 }
|
|
|
|
sensorAirflowSensorErrorColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A SensorError Color of this sensor"
|
|
::= { sensorAirflowEntry 59 }
|
|
|
|
--/* End of sensorAirflowEntry */
|
|
|
|
--/* Begin of sensorMotionEntry */
|
|
sensorMotionTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorMotionEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the property and reading value for every sensor."
|
|
::= { secSensor 8 }
|
|
|
|
sensorMotionEntry OBJECT-TYPE
|
|
SYNTAX SensorMotionEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorTemperatureEntry Table"
|
|
INDEX { sensorMotionIndex }
|
|
::= { sensorMotionTable 1 }
|
|
|
|
SensorMotionEntry ::= SEQUENCE {
|
|
sensorMotionIndex
|
|
INTEGER,
|
|
sensorMotionDescription
|
|
DisplayString,
|
|
sensorMotionStatus
|
|
INTEGER,
|
|
sensorMotionGoOffline
|
|
INTEGER,
|
|
sensorMotionPort
|
|
INTEGER,
|
|
sensorMotionSubPort
|
|
INTEGER,
|
|
sensorMotionDeviceIndex
|
|
INTEGER,
|
|
sensorMotionCriticalDesc
|
|
DisplayString,
|
|
sensorMotionNormalDesc
|
|
DisplayString,
|
|
sensorMotionCriticalColor
|
|
INTEGER,
|
|
sensorMotionNormalColor
|
|
INTEGER
|
|
}
|
|
|
|
sensorMotionIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index into the Switch sensor table"
|
|
::= { sensorMotionEntry 1 }
|
|
|
|
sensorMotionDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor Switch"
|
|
::= { sensorMotionEntry 2 }
|
|
|
|
sensorMotionStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highCritical(4),
|
|
lowCritical(6),
|
|
sensorError(7),
|
|
relayOn(8),
|
|
relayOff(9)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor, only input switches have a status"
|
|
::= { sensorMotionEntry 6 }
|
|
|
|
sensorMotionGoOffline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To take offline enter a 2"
|
|
::= { sensorMotionEntry 8 }
|
|
|
|
sensorMotionPort OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor port"
|
|
::= { sensorMotionEntry 35 }
|
|
|
|
sensorMotionSubPort OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor sub port"
|
|
::= { sensorMotionEntry 36 }
|
|
|
|
sensorMotionDeviceIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Device Index of sensor"
|
|
::= { sensorMotionEntry 37 }
|
|
|
|
sensorMotionCriticalDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Critical Description of this sensor"
|
|
::= { sensorMotionEntry 46 }
|
|
|
|
sensorMotionNormalDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Normal Description of this sensor"
|
|
::= { sensorMotionEntry 48 }
|
|
|
|
sensorMotionCriticalColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Critical Color of this sensor"
|
|
::= { sensorMotionEntry 54 }
|
|
|
|
sensorMotionNormalColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Normal Color of this sensor"
|
|
::= { sensorMotionEntry 56 }
|
|
|
|
--/* End of sensorMotionEntry */
|
|
|
|
--/* Begin of sensorWaterEntry */
|
|
sensorWaterTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorWaterEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the property and reading value for every sensor."
|
|
::= { secSensor 9 }
|
|
|
|
sensorWaterEntry OBJECT-TYPE
|
|
SYNTAX SensorWaterEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorTemperatureEntry Table"
|
|
INDEX { sensorWaterIndex }
|
|
::= { sensorWaterTable 1 }
|
|
|
|
SensorWaterEntry ::= SEQUENCE {
|
|
sensorWaterIndex
|
|
INTEGER,
|
|
sensorWaterDescription
|
|
DisplayString,
|
|
sensorWaterStatus
|
|
INTEGER,
|
|
sensorWaterGoOffline
|
|
INTEGER,
|
|
sensorWaterPort
|
|
INTEGER,
|
|
sensorWaterSubPort
|
|
INTEGER,
|
|
sensorWaterDeviceIndex
|
|
INTEGER,
|
|
sensorWaterCriticalDesc
|
|
DisplayString,
|
|
sensorWaterNormalDesc
|
|
DisplayString,
|
|
sensorWaterCriticalColor
|
|
INTEGER,
|
|
sensorWaterNormalColor
|
|
INTEGER
|
|
}
|
|
|
|
sensorWaterIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index into the Switch sensor table"
|
|
::= { sensorWaterEntry 1 }
|
|
|
|
sensorWaterDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor Switch"
|
|
::= { sensorWaterEntry 2 }
|
|
|
|
sensorWaterStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highCritical(4),
|
|
lowCritical(6),
|
|
sensorError(7),
|
|
relayOn(8),
|
|
relayOff(9)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor, only input switches have a status"
|
|
::= { sensorWaterEntry 6 }
|
|
|
|
sensorWaterGoOffline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To take offline enter a 2"
|
|
::= { sensorWaterEntry 8 }
|
|
|
|
sensorWaterPort OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor port"
|
|
::= { sensorWaterEntry 35 }
|
|
|
|
sensorWaterSubPort OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor sub port"
|
|
::= { sensorWaterEntry 36 }
|
|
|
|
sensorWaterDeviceIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Device Index of sensor"
|
|
::= { sensorWaterEntry 37 }
|
|
|
|
sensorWaterCriticalDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Critical Description of this sensor"
|
|
::= { sensorWaterEntry 46 }
|
|
|
|
sensorWaterNormalDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Normal Description of this sensor"
|
|
::= { sensorWaterEntry 48 }
|
|
|
|
sensorWaterCriticalColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Critical Color of this sensor"
|
|
::= { sensorWaterEntry 54 }
|
|
|
|
sensorWaterNormalColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Normal Color of this sensor"
|
|
::= { sensorWaterEntry 56 }
|
|
|
|
--/* End of sensorWaterEntry */
|
|
|
|
--/* Begin of sensorSecurityEntry */
|
|
sensorSecurityTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorSecurityEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the property and reading value for every sensor."
|
|
::= { secSensor 10 }
|
|
|
|
sensorSecurityEntry OBJECT-TYPE
|
|
SYNTAX SensorSecurityEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorTemperatureEntry Table"
|
|
INDEX { sensorSecurityIndex }
|
|
::= { sensorSecurityTable 1 }
|
|
|
|
SensorSecurityEntry ::= SEQUENCE {
|
|
sensorSecurityIndex
|
|
INTEGER,
|
|
sensorSecurityDescription
|
|
DisplayString,
|
|
sensorSecurityStatus
|
|
INTEGER,
|
|
sensorSecurityGoOffline
|
|
INTEGER,
|
|
sensorSecurityPort
|
|
INTEGER,
|
|
sensorSecuritySubPort
|
|
INTEGER,
|
|
sensorSecurityDeviceIndex
|
|
INTEGER,
|
|
sensorSecurityCriticalDesc
|
|
DisplayString,
|
|
sensorSecurityNormalDesc
|
|
DisplayString,
|
|
sensorSecurityCriticalColor
|
|
INTEGER,
|
|
sensorSecurityNormalColor
|
|
INTEGER
|
|
}
|
|
|
|
sensorSecurityIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index into the Switch sensor table"
|
|
::= { sensorSecurityEntry 1 }
|
|
|
|
sensorSecurityDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor Switch"
|
|
::= { sensorSecurityEntry 2 }
|
|
|
|
sensorSecurityStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highCritical(4),
|
|
lowCritical(6),
|
|
sensorError(7),
|
|
relayOn(8),
|
|
relayOff(9)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor, only input switches have a status"
|
|
::= { sensorSecurityEntry 6 }
|
|
|
|
sensorSecurityGoOffline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To take offline enter a 2"
|
|
::= { sensorSecurityEntry 8 }
|
|
|
|
sensorSecurityPort OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor port"
|
|
::= { sensorSecurityEntry 35 }
|
|
|
|
sensorSecuritySubPort OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor sub port"
|
|
::= { sensorSecurityEntry 36 }
|
|
|
|
sensorSecurityDeviceIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Device Index of sensor"
|
|
::= { sensorSecurityEntry 37 }
|
|
|
|
sensorSecurityCriticalDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Critical Description of this sensor"
|
|
::= { sensorSecurityEntry 46 }
|
|
|
|
sensorSecurityNormalDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Normal Description of this sensor"
|
|
::= { sensorSecurityEntry 48 }
|
|
|
|
sensorSecurityCriticalColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Critical Color of this sensor"
|
|
::= { sensorSecurityEntry 54 }
|
|
|
|
sensorSecurityNormalColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Normal Color of this sensor"
|
|
::= { sensorSecurityEntry 56 }
|
|
|
|
--/* End of sensorSecurityEntry */
|
|
|
|
--/* Begin of sensorSirenEntry */
|
|
sensorSirenTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorSirenEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the property and reading value for every sensor."
|
|
::= { secSensor 11 }
|
|
|
|
sensorSirenEntry OBJECT-TYPE
|
|
SYNTAX SensorSirenEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorTemperatureEntry Table"
|
|
INDEX { sensorSirenIndex }
|
|
::= { sensorSirenTable 1 }
|
|
|
|
SensorSirenEntry ::= SEQUENCE {
|
|
sensorSirenIndex
|
|
INTEGER,
|
|
sensorSirenDescription
|
|
DisplayString,
|
|
sensorSirenStatus
|
|
INTEGER,
|
|
sensorSirenGoOffline
|
|
INTEGER,
|
|
sensorSirenControlMode
|
|
INTEGER,
|
|
sensorSirenManualCycleTime
|
|
INTEGER,
|
|
sensorSirenManualAction
|
|
INTEGER,
|
|
sensorSirenPort
|
|
INTEGER,
|
|
sensorSirenSubPort
|
|
INTEGER,
|
|
sensorSirenDeviceIndex
|
|
INTEGER,
|
|
sensorSirenOnDesc
|
|
DisplayString,
|
|
sensorSirenOffDesc
|
|
DisplayString,
|
|
sensorSirenOnColor
|
|
INTEGER,
|
|
sensorSirenOffColor
|
|
INTEGER
|
|
}
|
|
|
|
sensorSirenIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index into the Switch sensor table"
|
|
::= { sensorSirenEntry 1 }
|
|
|
|
sensorSirenDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor Switch"
|
|
::= { sensorSirenEntry 2 }
|
|
|
|
sensorSirenStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highCritical(4),
|
|
lowCritical(6),
|
|
sensorError(7),
|
|
relayOn(8),
|
|
relayOff(9)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor, only input switches have a status"
|
|
::= { sensorSirenEntry 6 }
|
|
|
|
sensorSirenGoOffline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To take offline enter a 2"
|
|
::= { sensorSirenEntry 8 }
|
|
|
|
sensorSirenControlMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
manual-control(0),
|
|
sensor-control(1),
|
|
time-control(2),
|
|
thermostat-control(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Control Mode used for selecting the mode to control a siren."
|
|
::= { sensorSirenEntry 24 }
|
|
|
|
sensorSirenManualCycleTime OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Toggle period in seconds for Manual Cycle action."
|
|
::= { sensorSirenEntry 25 }
|
|
|
|
sensorSirenManualAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-On(0),
|
|
turn-Off(1),
|
|
cycle-On-Off-On(2),
|
|
cycle-Off-On-Off(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Control the siren manualy"
|
|
::= { sensorSirenEntry 26 }
|
|
|
|
sensorSirenPort OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor port"
|
|
::= { sensorSirenEntry 35 }
|
|
|
|
sensorSirenSubPort OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor sub port"
|
|
::= { sensorSirenEntry 36 }
|
|
|
|
sensorSirenDeviceIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Device Index of sensor"
|
|
::= { sensorSirenEntry 37 }
|
|
|
|
sensorSirenOnDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A On Description of this sensor"
|
|
::= { sensorSirenEntry 52 }
|
|
|
|
sensorSirenOffDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Off Description of this sensor"
|
|
::= { sensorSirenEntry 53 }
|
|
|
|
sensorSirenOnColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A On Color of this sensor"
|
|
::= { sensorSirenEntry 60 }
|
|
|
|
sensorSirenOffColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Off Color of this sensor"
|
|
::= { sensorSirenEntry 61 }
|
|
|
|
--/* End of sensorSirenEntry */
|
|
|
|
--/* Begin of sensorRelayEntry */
|
|
sensorRelayTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorRelayEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the property and reading value for every sensor."
|
|
::= { secSensor 12 }
|
|
|
|
sensorRelayEntry OBJECT-TYPE
|
|
SYNTAX SensorRelayEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorTemperatureEntry Table"
|
|
INDEX { sensorRelayIndex }
|
|
::= { sensorRelayTable 1 }
|
|
|
|
SensorRelayEntry ::= SEQUENCE {
|
|
sensorRelayIndex
|
|
INTEGER,
|
|
sensorRelayDescription
|
|
DisplayString,
|
|
sensorRelayType
|
|
INTEGER,
|
|
sensorRelayStatus
|
|
INTEGER,
|
|
sensorRelayGoOffline
|
|
INTEGER,
|
|
sensorRelayControlMode
|
|
INTEGER,
|
|
sensorRelayManualCycleTime
|
|
INTEGER,
|
|
sensorRelayManualAction
|
|
INTEGER,
|
|
sensorRelayPort
|
|
INTEGER,
|
|
sensorRelaySubPort
|
|
INTEGER,
|
|
sensorRelayDeviceIndex
|
|
INTEGER,
|
|
sensorRelayOnDesc
|
|
DisplayString,
|
|
sensorRelayOffDesc
|
|
DisplayString,
|
|
sensorRelayOnColor
|
|
INTEGER,
|
|
sensorRelayOffColor
|
|
INTEGER
|
|
}
|
|
|
|
sensorRelayIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index into the Switch sensor table"
|
|
::= { sensorRelayEntry 1 }
|
|
|
|
sensorRelayDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor Switch"
|
|
::= { sensorRelayEntry 2 }
|
|
|
|
sensorRelayType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
relay(13),
|
|
xrelay(19)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Enter the type of this Sensor"
|
|
::= { sensorRelayEntry 3 }
|
|
|
|
sensorRelayStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highCritical(4),
|
|
lowCritical(6),
|
|
sensorError(7),
|
|
relayOn(8),
|
|
relayOff(9)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor, only input switches have a status"
|
|
::= { sensorRelayEntry 6 }
|
|
|
|
sensorRelayGoOffline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To take offline enter a 2"
|
|
::= { sensorRelayEntry 8 }
|
|
|
|
sensorRelayControlMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
manual-control(0),
|
|
sensor-control(1),
|
|
time-control(2),
|
|
thermostat-control(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Control Mode used for selecting the mode to control a relay."
|
|
::= { sensorRelayEntry 24 }
|
|
|
|
sensorRelayManualCycleTime OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Toggle period in seconds for Manual Cycle action."
|
|
::= { sensorRelayEntry 25 }
|
|
|
|
sensorRelayManualAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
turn-On(0),
|
|
turn-Off(1),
|
|
cycle-On-Off-On(2),
|
|
cycle-Off-On-Off(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Control the relay manualy"
|
|
::= { sensorRelayEntry 26 }
|
|
|
|
sensorRelayPort OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor port"
|
|
::= { sensorRelayEntry 35 }
|
|
|
|
sensorRelaySubPort OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor sub port"
|
|
::= { sensorRelayEntry 36 }
|
|
|
|
sensorRelayDeviceIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Device Index of sensor"
|
|
::= { sensorRelayEntry 37 }
|
|
|
|
sensorRelayOnDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A On Description of this sensor"
|
|
::= { sensorRelayEntry 52 }
|
|
|
|
sensorRelayOffDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Off Description of this sensor"
|
|
::= { sensorRelayEntry 53 }
|
|
|
|
sensorRelayOnColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A On Color of this sensor"
|
|
::= { sensorRelayEntry 60 }
|
|
|
|
sensorRelayOffColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Off Color of this sensor"
|
|
::= { sensorRelayEntry 61 }
|
|
|
|
--/* End of sensorRelayEntry */
|
|
|
|
--/* Begin of sensorACvoltageEntry */
|
|
sensorACvoltageTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorACvoltageEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the property and reading value for every sensor."
|
|
::= { secSensor 13 }
|
|
|
|
sensorACvoltageEntry OBJECT-TYPE
|
|
SYNTAX SensorACvoltageEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorTemperatureEntry Table"
|
|
INDEX { sensorACvoltageIndex }
|
|
::= { sensorACvoltageTable 1 }
|
|
|
|
SensorACvoltageEntry ::= SEQUENCE {
|
|
sensorACvoltageIndex
|
|
INTEGER,
|
|
sensorACvoltageDescription
|
|
DisplayString,
|
|
sensorACvoltageStatus
|
|
INTEGER,
|
|
sensorACvoltageGoOffline
|
|
INTEGER,
|
|
sensorACvoltagePort
|
|
INTEGER,
|
|
sensorACvoltageSubPort
|
|
INTEGER,
|
|
sensorACvoltageDeviceIndex
|
|
INTEGER,
|
|
sensorACvoltageCriticalDesc
|
|
DisplayString,
|
|
sensorACvoltageNormalDesc
|
|
DisplayString,
|
|
sensorACvoltageCriticalColor
|
|
INTEGER,
|
|
sensorACvoltageNormalColor
|
|
INTEGER
|
|
}
|
|
|
|
sensorACvoltageIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index into the Switch sensor table"
|
|
::= { sensorACvoltageEntry 1 }
|
|
|
|
sensorACvoltageDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor Switch"
|
|
::= { sensorACvoltageEntry 2 }
|
|
|
|
sensorACvoltageStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highCritical(4),
|
|
lowCritical(6),
|
|
sensorError(7),
|
|
relayOn(8),
|
|
relayOff(9)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor, only input switches have a status"
|
|
::= { sensorACvoltageEntry 6 }
|
|
|
|
sensorACvoltageGoOffline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To put online enter a 1, to take offline enter a 2"
|
|
::= { sensorACvoltageEntry 8 }
|
|
|
|
sensorACvoltagePort OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor port"
|
|
::= { sensorACvoltageEntry 35 }
|
|
|
|
sensorACvoltageSubPort OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor sub port"
|
|
::= { sensorACvoltageEntry 36 }
|
|
|
|
sensorACvoltageDeviceIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Device Index of sensor"
|
|
::= { sensorACvoltageEntry 37 }
|
|
|
|
sensorACvoltageCriticalDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Critical Description of this sensor"
|
|
::= { sensorACvoltageEntry 46 }
|
|
|
|
sensorACvoltageNormalDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Normal Description of this sensor"
|
|
::= { sensorACvoltageEntry 48 }
|
|
|
|
sensorACvoltageCriticalColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Critical Color of this sensor"
|
|
::= { sensorACvoltageEntry 54 }
|
|
|
|
sensorACvoltageNormalColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Normal Color of this sensor"
|
|
::= { sensorACvoltageEntry 56 }
|
|
|
|
--/* End of sensorACvoltageEntry */
|
|
|
|
--/* Begin of sensorSmokeEntry */
|
|
sensorSmokeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorSmokeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the property and reading value for every sensor."
|
|
::= { secSensor 14 }
|
|
|
|
sensorSmokeEntry OBJECT-TYPE
|
|
SYNTAX SensorSmokeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorTemperatureEntry Table"
|
|
INDEX { sensorSmokeIndex }
|
|
::= { sensorSmokeTable 1 }
|
|
|
|
SensorSmokeEntry ::= SEQUENCE {
|
|
sensorSmokeIndex
|
|
INTEGER,
|
|
sensorSmokeDescription
|
|
DisplayString,
|
|
sensorSmokeStatus
|
|
INTEGER,
|
|
sensorSmokeGoOffline
|
|
INTEGER,
|
|
sensorSmokePort
|
|
INTEGER,
|
|
sensorSmokeSubPort
|
|
INTEGER,
|
|
sensorSmokeDeviceIndex
|
|
INTEGER,
|
|
sensorSmokeCriticalDesc
|
|
DisplayString,
|
|
sensorSmokeNormalDesc
|
|
DisplayString,
|
|
sensorSmokeCriticalColor
|
|
INTEGER,
|
|
sensorSmokeNormalColor
|
|
INTEGER
|
|
}
|
|
|
|
sensorSmokeIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index into the Switch sensor table"
|
|
::= { sensorSmokeEntry 1 }
|
|
|
|
sensorSmokeDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor Switch"
|
|
::= { sensorSmokeEntry 2 }
|
|
|
|
sensorSmokeStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highCritical(4),
|
|
lowCritical(6),
|
|
sensorError(7),
|
|
relayOn(8),
|
|
relayOff(9)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor, only input switches have a status"
|
|
::= { sensorSmokeEntry 6 }
|
|
|
|
sensorSmokeGoOffline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To take offline enter a 2"
|
|
::= { sensorSmokeEntry 8 }
|
|
|
|
sensorSmokePort OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor port"
|
|
::= { sensorSmokeEntry 35 }
|
|
|
|
sensorSmokeSubPort OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor sub port"
|
|
::= { sensorSmokeEntry 36 }
|
|
|
|
sensorSmokeDeviceIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Device Index of sensor"
|
|
::= { sensorSmokeEntry 37 }
|
|
|
|
sensorSmokeCriticalDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Critical Description of this sensor"
|
|
::= { sensorSmokeEntry 46 }
|
|
|
|
sensorSmokeNormalDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Normal Description of this sensor"
|
|
::= { sensorSmokeEntry 48 }
|
|
|
|
sensorSmokeCriticalColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Critical Color of this sensor"
|
|
::= { sensorSmokeEntry 54 }
|
|
|
|
sensorSmokeNormalColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Normal Color of this sensor"
|
|
::= { sensorSmokeEntry 56 }
|
|
|
|
--/* End of sensorSmokeEntry */
|
|
|
|
--/* Begin of sensorThermostatEntry */
|
|
sensorThermostatTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorThermostatEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the property and reading value for every sensor."
|
|
::= { secSensor 20 }
|
|
|
|
sensorThermostatEntry OBJECT-TYPE
|
|
SYNTAX SensorThermostatEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorTemperatureEntry Table"
|
|
INDEX { sensorThermostatIndex }
|
|
::= { sensorThermostatTable 1 }
|
|
|
|
SensorThermostatEntry ::= SEQUENCE {
|
|
sensorThermostatIndex
|
|
INTEGER,
|
|
sensorThermostatDescription
|
|
DisplayString,
|
|
sensorThermostatDegree
|
|
INTEGER,
|
|
sensorThermostatStatus
|
|
INTEGER,
|
|
sensorThermostatGoOffline
|
|
INTEGER,
|
|
sensorThermostatLowCritical
|
|
INTEGER,
|
|
sensorThermostatLowWarning
|
|
INTEGER,
|
|
sensorThermostatHighWarning
|
|
INTEGER,
|
|
sensorThermostatHighCritical
|
|
INTEGER,
|
|
sensorThermostatRearm
|
|
INTEGER,
|
|
sensorThermostatDelayError
|
|
INTEGER,
|
|
sensorThermostatDelayNormal
|
|
INTEGER,
|
|
sensorThermostatDelayLowCritical
|
|
INTEGER,
|
|
sensorThermostatDelayLowWarning
|
|
INTEGER,
|
|
sensorThermostatDelayHighWarning
|
|
INTEGER,
|
|
sensorThermostatDelayHighCritical
|
|
INTEGER,
|
|
sensorThermostatPort
|
|
INTEGER,
|
|
sensorThermostatSubPort
|
|
INTEGER,
|
|
sensorThermostatDeviceIndex
|
|
INTEGER,
|
|
sensorThermostatDisplayStyle
|
|
INTEGER,
|
|
sensorThermostatHighCriticalDesc
|
|
DisplayString,
|
|
sensorThermostatLowCriticalDesc
|
|
DisplayString,
|
|
sensorThermostatNormalDesc
|
|
DisplayString,
|
|
sensorThermostatLowWarningDesc
|
|
DisplayString,
|
|
sensorThermostatHighWarningDesc
|
|
DisplayString,
|
|
sensorThermostatSensorErrorDesc
|
|
DisplayString,
|
|
sensorThermostatHighCriticalColor
|
|
INTEGER,
|
|
sensorThermostatLowCriticalColor
|
|
INTEGER,
|
|
sensorThermostatNormalColor
|
|
INTEGER,
|
|
sensorThermostatLowWarningColor
|
|
INTEGER,
|
|
sensorThermostatHighWarningColor
|
|
INTEGER,
|
|
sensorThermostatSensorErrorColor
|
|
INTEGER
|
|
}
|
|
|
|
sensorThermostatIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index into the sensor table"
|
|
::= { sensorThermostatEntry 1 }
|
|
|
|
sensorThermostatDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor"
|
|
::= { sensorThermostatEntry 2 }
|
|
|
|
sensorThermostatDegree OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The degrees in this sensor"
|
|
::= { sensorThermostatEntry 4 }
|
|
|
|
sensorThermostatStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highWarning(3),
|
|
highCritical(4),
|
|
lowWarning(5),
|
|
lowCritical(6),
|
|
sensorError(7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor"
|
|
::= { sensorThermostatEntry 6 }
|
|
|
|
sensorThermostatGoOffline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To take offline enter a 2"
|
|
::= { sensorThermostatEntry 8 }
|
|
|
|
sensorThermostatLowCritical OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How cold this sensor gets before it sends a critical event"
|
|
::= { sensorThermostatEntry 9 }
|
|
|
|
sensorThermostatLowWarning OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How cold this sensor gets before it sends a warning"
|
|
::= { sensorThermostatEntry 10 }
|
|
|
|
sensorThermostatHighWarning OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How hot this sensor gets before it sends a warning"
|
|
::= { sensorThermostatEntry 11 }
|
|
|
|
sensorThermostatHighCritical OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How hot this sensor gets before it sends a critical event"
|
|
::= { sensorThermostatEntry 12 }
|
|
|
|
sensorThermostatRearm OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of degrees to rearm the status. For example if status goes from normal to warning, the temp must go down spTempRearm degrees below warning before the status goes to normal"
|
|
::= { sensorThermostatEntry 13 }
|
|
|
|
sensorThermostatDelayError OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time in seconds after the sensor has been in error status before report as an error"
|
|
::= { sensorThermostatEntry 14 }
|
|
|
|
sensorThermostatDelayNormal OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time in seconds after the sensor change from error to normal before report as normal"
|
|
::= { sensorThermostatEntry 15 }
|
|
|
|
sensorThermostatDelayLowCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Low Critical before accepting new Status."
|
|
::= { sensorThermostatEntry 16 }
|
|
|
|
sensorThermostatDelayLowWarning OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Low Warning before accepting new Status."
|
|
::= { sensorThermostatEntry 17 }
|
|
|
|
sensorThermostatDelayHighWarning OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in High Warning before accepting new Status."
|
|
::= { sensorThermostatEntry 18 }
|
|
|
|
sensorThermostatDelayHighCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in High Critical before accepting new Status."
|
|
::= { sensorThermostatEntry 19 }
|
|
|
|
sensorThermostatPort OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor port"
|
|
::= { sensorThermostatEntry 35 }
|
|
|
|
sensorThermostatSubPort OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor sub port"
|
|
::= { sensorThermostatEntry 36 }
|
|
|
|
sensorThermostatDeviceIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Device Index of sensor"
|
|
::= { sensorThermostatEntry 37 }
|
|
|
|
sensorThermostatDisplayStyle OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
basic(0),
|
|
gauge(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Thermostat display style"
|
|
::= { sensorThermostatEntry 45 }
|
|
|
|
sensorThermostatHighCriticalDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A HighCritical Description of this sensor"
|
|
::= { sensorThermostatEntry 46 }
|
|
|
|
sensorThermostatLowCriticalDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A LowCritical Description of this sensor"
|
|
::= { sensorThermostatEntry 47 }
|
|
|
|
sensorThermostatNormalDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Normal Description of this sensor"
|
|
::= { sensorThermostatEntry 48 }
|
|
|
|
sensorThermostatLowWarningDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A LowWarning Description of this sensor"
|
|
::= { sensorThermostatEntry 49 }
|
|
|
|
sensorThermostatHighWarningDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A HighWarning Description of this sensor"
|
|
::= { sensorThermostatEntry 50 }
|
|
|
|
sensorThermostatSensorErrorDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A SensorError Description of this sensor"
|
|
::= { sensorThermostatEntry 51 }
|
|
|
|
sensorThermostatHighCriticalColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A HighCritical Color of this sensor"
|
|
::= { sensorThermostatEntry 54 }
|
|
|
|
sensorThermostatLowCriticalColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A LowCritical Color of this sensor"
|
|
::= { sensorThermostatEntry 55 }
|
|
|
|
sensorThermostatNormalColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Normal Color of this sensor"
|
|
::= { sensorThermostatEntry 56 }
|
|
|
|
sensorThermostatLowWarningColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A LowWarning Color of this sensor"
|
|
::= { sensorThermostatEntry 57 }
|
|
|
|
sensorThermostatHighWarningColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A HighWarning Color of this sensor"
|
|
::= { sensorThermostatEntry 58 }
|
|
|
|
sensorThermostatSensorErrorColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A SensorError Color of this sensor"
|
|
::= { sensorThermostatEntry 59 }
|
|
|
|
--/* End of sensorThermostatEntry */
|
|
|
|
--/* Begin of sensorWaterRopeEntry */
|
|
sensorWaterRopeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorWaterRopeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the property and reading value for every sensor."
|
|
::= { secSensor 21 }
|
|
|
|
sensorWaterRopeEntry OBJECT-TYPE
|
|
SYNTAX SensorWaterRopeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the SensorWaterRopeEntry Table"
|
|
INDEX { sensorWaterRopeIndex }
|
|
::= { sensorWaterRopeTable 1 }
|
|
|
|
SensorWaterRopeEntry ::= SEQUENCE {
|
|
sensorWaterRopeIndex
|
|
INTEGER,
|
|
sensorWaterRopeDescription
|
|
DisplayString,
|
|
sensorWaterRopeLeakLocation
|
|
INTEGER,
|
|
sensorWaterRopeUnit
|
|
DisplayString,
|
|
sensorWaterRopeStatus
|
|
INTEGER,
|
|
sensorWaterRopeGoOffline
|
|
INTEGER,
|
|
sensorWaterRopeRaw
|
|
INTEGER,
|
|
sensorWaterRopeDeviceIndex
|
|
INTEGER,
|
|
sensorWaterRopeCriticalDesc
|
|
DisplayString,
|
|
sensorWaterRopeNormalDesc
|
|
DisplayString,
|
|
sensorWaterRopeSensorErrorDesc
|
|
DisplayString,
|
|
sensorWaterRopeCriticalColor
|
|
INTEGER,
|
|
sensorWaterRopeNormalColor
|
|
INTEGER,
|
|
sensorWaterRopeSensorErrorColor
|
|
INTEGER,
|
|
sensorWaterRopeLength
|
|
INTEGER,
|
|
sensorWaterRopeImpedance
|
|
INTEGER,
|
|
sensorWaterRopeType
|
|
INTEGER
|
|
}
|
|
|
|
sensorWaterRopeIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index into the sensor table"
|
|
::= { sensorWaterRopeEntry 1 }
|
|
|
|
sensorWaterRopeDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor"
|
|
::= { sensorWaterRopeEntry 2 }
|
|
|
|
sensorWaterRopeLeakLocation OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Location of leakage of water rope sensor."
|
|
::= { sensorWaterRopeEntry 4 }
|
|
|
|
sensorWaterRopeUnit OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Display unit of water rope sensor."
|
|
::= { sensorWaterRopeEntry 5 }
|
|
|
|
sensorWaterRopeStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highCritical(4),
|
|
sensorError(7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor"
|
|
::= { sensorWaterRopeEntry 6 }
|
|
|
|
sensorWaterRopeGoOffline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To take offline enter a 2"
|
|
::= { sensorWaterRopeEntry 8 }
|
|
|
|
sensorWaterRopeRaw OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Raw value of location or length in ohms"
|
|
::= { sensorWaterRopeEntry 20 }
|
|
|
|
sensorWaterRopeDeviceIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Device Index of sensor"
|
|
::= { sensorWaterRopeEntry 37 }
|
|
|
|
sensorWaterRopeCriticalDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Critical Description of this sensor"
|
|
::= { sensorWaterRopeEntry 46 }
|
|
|
|
sensorWaterRopeNormalDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Normal Description of this sensor"
|
|
::= { sensorWaterRopeEntry 48 }
|
|
|
|
sensorWaterRopeSensorErrorDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A SensorError Description of this sensor"
|
|
::= { sensorWaterRopeEntry 51 }
|
|
|
|
sensorWaterRopeCriticalColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Critical Color of this sensor"
|
|
::= { sensorWaterRopeEntry 54 }
|
|
|
|
sensorWaterRopeNormalColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Normal Color of this sensor"
|
|
::= { sensorWaterRopeEntry 56 }
|
|
|
|
sensorWaterRopeSensorErrorColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A SensorError Color of this sensor"
|
|
::= { sensorWaterRopeEntry 59 }
|
|
|
|
sensorWaterRopeLength OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Length of water rope sensor."
|
|
::= { sensorWaterRopeEntry 100 }
|
|
|
|
sensorWaterRopeImpedance OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensing wire impedance per meter value times 100"
|
|
::= { sensorWaterRopeEntry 101 }
|
|
|
|
sensorWaterRopeType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
custom(0),
|
|
water(1),
|
|
fuel(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Water rope sensing cable type"
|
|
::= { sensorWaterRopeEntry 103 }
|
|
|
|
--/* End of sensorWaterRopeEntry */
|
|
|
|
--/* Begin of sensorPowerEntry */
|
|
sensorPowerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorPowerEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the property and reading value for every sensor."
|
|
::= { secSensor 22 }
|
|
|
|
sensorPowerEntry OBJECT-TYPE
|
|
SYNTAX SensorPowerEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorPowerEntry Table"
|
|
INDEX { sensorPowerIndex }
|
|
::= { sensorPowerTable 1 }
|
|
|
|
SensorPowerEntry ::= SEQUENCE {
|
|
sensorPowerIndex
|
|
INTEGER,
|
|
sensorPowerDescription
|
|
DisplayString,
|
|
sensorPowerValue
|
|
INTEGER,
|
|
sensorPowerUnit
|
|
DisplayString,
|
|
sensorPowerStatus
|
|
INTEGER,
|
|
sensorPowerGoOffline
|
|
INTEGER,
|
|
sensorPowerLowCritical
|
|
INTEGER,
|
|
sensorPowerLowWarning
|
|
INTEGER,
|
|
sensorPowerHighWarning
|
|
INTEGER,
|
|
sensorPowerHighCritical
|
|
INTEGER,
|
|
sensorPowerRearm
|
|
INTEGER,
|
|
sensorPowerDelayError
|
|
INTEGER,
|
|
sensorPowerDelayNormal
|
|
INTEGER,
|
|
sensorPowerDelayLowCritical
|
|
INTEGER,
|
|
sensorPowerDelayLowWarning
|
|
INTEGER,
|
|
sensorPowerDelayHighWarning
|
|
INTEGER,
|
|
sensorPowerDelayHighCritical
|
|
INTEGER,
|
|
sensorPowerPort
|
|
INTEGER,
|
|
sensorPowerSubPort
|
|
INTEGER,
|
|
sensorPowerDeviceIndex
|
|
INTEGER,
|
|
sensorPowerTimeOut
|
|
INTEGER,
|
|
sensorPowerInterval
|
|
INTEGER,
|
|
sensorPowerErrorRetryNum
|
|
INTEGER,
|
|
sensorPowerMaxValue
|
|
INTEGER,
|
|
sensorPowerMinValue
|
|
INTEGER,
|
|
sensorPowerDisplayStyle
|
|
INTEGER,
|
|
sensorPowerHighCriticalDesc
|
|
DisplayString,
|
|
sensorPowerLowCriticalDesc
|
|
DisplayString,
|
|
sensorPowerNormalDesc
|
|
DisplayString,
|
|
sensorPowerLowWarningDesc
|
|
DisplayString,
|
|
sensorPowerHighWarningDesc
|
|
DisplayString,
|
|
sensorPowerSensorErrorDesc
|
|
DisplayString,
|
|
sensorPowerHighCriticalColor
|
|
INTEGER,
|
|
sensorPowerLowCriticalColor
|
|
INTEGER,
|
|
sensorPowerNormalColor
|
|
INTEGER,
|
|
sensorPowerLowWarningColor
|
|
INTEGER,
|
|
sensorPowerHighWarningColor
|
|
INTEGER,
|
|
sensorPowerSensorErrorColor
|
|
INTEGER
|
|
}
|
|
|
|
sensorPowerIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index into the Switch sensor table"
|
|
::= { sensorPowerEntry 1 }
|
|
|
|
sensorPowerDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor Switch"
|
|
::= { sensorPowerEntry 2 }
|
|
|
|
sensorPowerValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The reading value in this sensor"
|
|
::= { sensorPowerEntry 4 }
|
|
|
|
sensorPowerUnit OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit string"
|
|
::= { sensorPowerEntry 5 }
|
|
|
|
sensorPowerStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highCritical(4),
|
|
lowCritical(6),
|
|
sensorError(7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor, only input switches have a status"
|
|
::= { sensorPowerEntry 6 }
|
|
|
|
sensorPowerGoOffline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To take offline enter a 2"
|
|
::= { sensorPowerEntry 8 }
|
|
|
|
sensorPowerLowCritical OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How cold this sensor gets before it sends a critical event"
|
|
::= { sensorPowerEntry 9 }
|
|
|
|
sensorPowerLowWarning OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How cold this sensor gets before it sends a warning"
|
|
::= { sensorPowerEntry 10 }
|
|
|
|
sensorPowerHighWarning OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How hot this sensor gets before it sends a warning"
|
|
::= { sensorPowerEntry 11 }
|
|
|
|
sensorPowerHighCritical OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"How hot this sensor gets before it sends a critical event"
|
|
::= { sensorPowerEntry 12 }
|
|
|
|
sensorPowerRearm OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of degrees to rearm the status. For example if status goes from normal to warning, the temp must go down spTempRearm degrees below warning before the status goes to normal"
|
|
::= { sensorPowerEntry 13 }
|
|
|
|
sensorPowerDelayError OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time in seconds after the sensor has been in error status before report as an error"
|
|
::= { sensorPowerEntry 14 }
|
|
|
|
sensorPowerDelayNormal OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time in seconds after the sensor change from error to normal before report as normal"
|
|
::= { sensorPowerEntry 15 }
|
|
|
|
sensorPowerDelayLowCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Low Critical before accepting new Status."
|
|
::= { sensorPowerEntry 16 }
|
|
|
|
sensorPowerDelayLowWarning OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Low Warning before accepting new Status."
|
|
::= { sensorPowerEntry 17 }
|
|
|
|
sensorPowerDelayHighWarning OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in High Warning before accepting new Status."
|
|
::= { sensorPowerEntry 18 }
|
|
|
|
sensorPowerDelayHighCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in High Critical before accepting new Status."
|
|
::= { sensorPowerEntry 19 }
|
|
|
|
sensorPowerPort OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor port"
|
|
::= { sensorPowerEntry 35 }
|
|
|
|
sensorPowerSubPort OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor sub port"
|
|
::= { sensorPowerEntry 36 }
|
|
|
|
sensorPowerDeviceIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Device Index of sensor"
|
|
::= { sensorPowerEntry 37 }
|
|
|
|
sensorPowerTimeOut OBJECT-TYPE
|
|
SYNTAX INTEGER (5..30)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The polling timeout of Power Sensor."
|
|
::= { sensorPowerEntry 38 }
|
|
|
|
sensorPowerInterval OBJECT-TYPE
|
|
SYNTAX INTEGER (5..720)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The polling interval of Power Sensor."
|
|
::= { sensorPowerEntry 39 }
|
|
|
|
sensorPowerErrorRetryNum OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of retry before error."
|
|
::= { sensorPowerEntry 40 }
|
|
|
|
sensorPowerMaxValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum scale of Power value."
|
|
::= { sensorPowerEntry 41 }
|
|
|
|
sensorPowerMinValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum scale of Power value."
|
|
::= { sensorPowerEntry 42 }
|
|
|
|
sensorPowerDisplayStyle OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
basic(0),
|
|
gauge(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Power display style."
|
|
::= { sensorPowerEntry 45 }
|
|
|
|
sensorPowerHighCriticalDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A HighCritical Description of this sensor"
|
|
::= { sensorPowerEntry 46 }
|
|
|
|
sensorPowerLowCriticalDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A LowCritical Description of this sensor"
|
|
::= { sensorPowerEntry 47 }
|
|
|
|
sensorPowerNormalDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Normal Description of this sensor"
|
|
::= { sensorPowerEntry 48 }
|
|
|
|
sensorPowerLowWarningDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A LowWarning Description of this sensor"
|
|
::= { sensorPowerEntry 49 }
|
|
|
|
sensorPowerHighWarningDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A HighWarning Description of this sensor"
|
|
::= { sensorPowerEntry 50 }
|
|
|
|
sensorPowerSensorErrorDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A SensorError Description of this sensor"
|
|
::= { sensorPowerEntry 51 }
|
|
|
|
sensorPowerHighCriticalColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A HighCritical Color of this sensor"
|
|
::= { sensorPowerEntry 54 }
|
|
|
|
sensorPowerLowCriticalColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A LowCritical Color of this sensor"
|
|
::= { sensorPowerEntry 55 }
|
|
|
|
sensorPowerNormalColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Normal Color of this sensor"
|
|
::= { sensorPowerEntry 56 }
|
|
|
|
sensorPowerLowWarningColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A LowWarning Color of this sensor"
|
|
::= { sensorPowerEntry 57 }
|
|
|
|
sensorPowerHighWarningColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A HighWarning Color of this sensor"
|
|
::= { sensorPowerEntry 58 }
|
|
|
|
sensorPowerSensorErrorColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A SensorError Color of this sensor"
|
|
::= { sensorPowerEntry 59 }
|
|
|
|
--/* End of sensorPowerEntry */
|
|
|
|
--/* Begin of sensorFuelEntry */
|
|
sensorFuelTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorFuelEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the property and reading value for every sensor."
|
|
::= { secSensor 24 }
|
|
|
|
sensorFuelEntry OBJECT-TYPE
|
|
SYNTAX SensorFuelEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the SensorFuelEntry Table"
|
|
INDEX { sensorFuelIndex }
|
|
::= { sensorFuelTable 1 }
|
|
|
|
SensorFuelEntry ::= SEQUENCE {
|
|
sensorFuelIndex
|
|
INTEGER,
|
|
sensorFuelDescription
|
|
DisplayString,
|
|
sensorFuelValue
|
|
INTEGER,
|
|
sensorFuelUnit
|
|
DisplayString,
|
|
sensorFuelStatus
|
|
INTEGER,
|
|
sensorFuelGoOffline
|
|
INTEGER,
|
|
sensorFuelLowCritical
|
|
INTEGER,
|
|
sensorFuelLowWarning
|
|
INTEGER,
|
|
sensorFuelHighWarning
|
|
INTEGER,
|
|
sensorFuelHighCritical
|
|
INTEGER,
|
|
sensorFuelRearm
|
|
INTEGER,
|
|
sensorFuelDelayError
|
|
INTEGER,
|
|
sensorFuelDelayNormal
|
|
INTEGER,
|
|
sensorFuelDelayLowCritical
|
|
INTEGER,
|
|
sensorFuelDelayLowWarning
|
|
INTEGER,
|
|
sensorFuelDelayHighWarning
|
|
INTEGER,
|
|
sensorFuelDelayHighCritical
|
|
INTEGER,
|
|
sensorFuelRaw
|
|
INTEGER,
|
|
sensorFuelAmountMaxValue
|
|
INTEGER,
|
|
sensorFuelAmountBaseValue
|
|
INTEGER,
|
|
sensorFuelDeviceIndex
|
|
INTEGER,
|
|
sensorFuelDisplayStyle
|
|
INTEGER,
|
|
sensorFuelHighCriticalDesc
|
|
DisplayString,
|
|
sensorFuelLowCriticalDesc
|
|
DisplayString,
|
|
sensorFuelNormalDesc
|
|
DisplayString,
|
|
sensorFuelLowWarningDesc
|
|
DisplayString,
|
|
sensorFuelHighWarningDesc
|
|
DisplayString,
|
|
sensorFuelSensorErrorDesc
|
|
DisplayString,
|
|
sensorFuelHighCriticalColor
|
|
INTEGER,
|
|
sensorFuelLowCriticalColor
|
|
INTEGER,
|
|
sensorFuelNormalColor
|
|
INTEGER,
|
|
sensorFuelLowWarningColor
|
|
INTEGER,
|
|
sensorFuelHighWarningColor
|
|
INTEGER,
|
|
sensorFuelSensorErrorColor
|
|
INTEGER
|
|
}
|
|
|
|
sensorFuelIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index into the sensor table"
|
|
::= { sensorFuelEntry 1 }
|
|
|
|
sensorFuelDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor"
|
|
::= { sensorFuelEntry 2 }
|
|
|
|
sensorFuelValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The reading value in this sensor"
|
|
::= { sensorFuelEntry 4 }
|
|
|
|
sensorFuelUnit OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit string"
|
|
::= { sensorFuelEntry 5 }
|
|
|
|
sensorFuelStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highWarning(3),
|
|
highCritical(4),
|
|
lowWarning(5),
|
|
lowCritical(6),
|
|
sensorError(7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor"
|
|
::= { sensorFuelEntry 6 }
|
|
|
|
sensorFuelGoOffline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To take offline enter a 2"
|
|
::= { sensorFuelEntry 8 }
|
|
|
|
sensorFuelLowCritical OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Level value of this sensor gets before it sends a critical event"
|
|
::= { sensorFuelEntry 9 }
|
|
|
|
sensorFuelLowWarning OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Level value of this sensor gets before it sends a warning"
|
|
::= { sensorFuelEntry 10 }
|
|
|
|
sensorFuelHighWarning OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Level value of this sensor gets before it sends a warning"
|
|
::= { sensorFuelEntry 11 }
|
|
|
|
sensorFuelHighCritical OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Level value of this sensor gets before it sends a critical event"
|
|
::= { sensorFuelEntry 12 }
|
|
|
|
sensorFuelRearm OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of degrees to rearm the status. For example if status goes from normal to warning, the temp must go down spTempRearm degrees below warning before the status goes to normal"
|
|
::= { sensorFuelEntry 13 }
|
|
|
|
sensorFuelDelayError OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time in seconds after the sensor has been in error status before report as an error"
|
|
::= { sensorFuelEntry 14 }
|
|
|
|
sensorFuelDelayNormal OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time in seconds after the sensor change from error to normal before report as normal"
|
|
::= { sensorFuelEntry 15 }
|
|
|
|
sensorFuelDelayLowCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Low Critical before accepting new Status."
|
|
::= { sensorFuelEntry 16 }
|
|
|
|
sensorFuelDelayLowWarning OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Low Warning before accepting new Status."
|
|
::= { sensorFuelEntry 17 }
|
|
|
|
sensorFuelDelayHighWarning OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in High Warning before accepting new Status."
|
|
::= { sensorFuelEntry 18 }
|
|
|
|
sensorFuelDelayHighCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in High Critical before accepting new Status."
|
|
::= { sensorFuelEntry 19 }
|
|
|
|
sensorFuelRaw OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unformatted, raw, A/D value in this sensor. Contains more resolution than the formated percentage."
|
|
::= { sensorFuelEntry 20 }
|
|
|
|
sensorFuelAmountMaxValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum scale of value conversion."
|
|
::= { sensorFuelEntry 33 }
|
|
|
|
sensorFuelAmountBaseValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The base scale of value conversion."
|
|
::= { sensorFuelEntry 34 }
|
|
|
|
sensorFuelDeviceIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Device Index of sensor"
|
|
::= { sensorFuelEntry 37 }
|
|
|
|
sensorFuelDisplayStyle OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
basic(0),
|
|
gauge(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Fuel display style"
|
|
::= { sensorFuelEntry 45 }
|
|
|
|
sensorFuelHighCriticalDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A HighCritical Description of this sensor"
|
|
::= { sensorFuelEntry 46 }
|
|
|
|
sensorFuelLowCriticalDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A LowCritical Description of this sensor"
|
|
::= { sensorFuelEntry 47 }
|
|
|
|
sensorFuelNormalDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Normal Description of this sensor"
|
|
::= { sensorFuelEntry 48 }
|
|
|
|
sensorFuelLowWarningDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A LowWarning Description of this sensor"
|
|
::= { sensorFuelEntry 49 }
|
|
|
|
sensorFuelHighWarningDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A HighWarning Description of this sensor"
|
|
::= { sensorFuelEntry 50 }
|
|
|
|
sensorFuelSensorErrorDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A SensorError Description of this sensor"
|
|
::= { sensorFuelEntry 51 }
|
|
|
|
sensorFuelHighCriticalColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A HighCritical Color of this sensor"
|
|
::= { sensorFuelEntry 54 }
|
|
|
|
sensorFuelLowCriticalColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A LowCritical Color of this sensor"
|
|
::= { sensorFuelEntry 55 }
|
|
|
|
sensorFuelNormalColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Normal Color of this sensor"
|
|
::= { sensorFuelEntry 56 }
|
|
|
|
sensorFuelLowWarningColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A LowWarning Color of this sensor"
|
|
::= { sensorFuelEntry 57 }
|
|
|
|
sensorFuelHighWarningColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A HighWarning Color of this sensor"
|
|
::= { sensorFuelEntry 58 }
|
|
|
|
sensorFuelSensorErrorColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A SensorError Color of this sensor"
|
|
::= { sensorFuelEntry 59 }
|
|
|
|
--/* End of sensorFuelEntry */
|
|
|
|
--/* Begin of sensorTankSenderEntry */
|
|
sensorTankSenderTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorTankSenderEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the property and reading value for every sensor."
|
|
::= { secSensor 26 }
|
|
|
|
sensorTankSenderEntry OBJECT-TYPE
|
|
SYNTAX SensorTankSenderEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is an entry in the sensorTankSenderEntry Table"
|
|
INDEX { sensorTankSenderIndex }
|
|
::= { sensorTankSenderTable 1 }
|
|
|
|
SensorTankSenderEntry ::= SEQUENCE {
|
|
sensorTankSenderIndex
|
|
INTEGER,
|
|
sensorTankSenderDescription
|
|
DisplayString,
|
|
sensorTankSenderValue
|
|
INTEGER,
|
|
sensorTankSenderUnit
|
|
DisplayString,
|
|
sensorTankSenderStatus
|
|
INTEGER,
|
|
sensorTankSenderGoOffline
|
|
INTEGER,
|
|
sensorTankSenderLowCritical
|
|
INTEGER,
|
|
sensorTankSenderLowWarning
|
|
INTEGER,
|
|
sensorTankSenderHighWarning
|
|
INTEGER,
|
|
sensorTankSenderHighCritical
|
|
INTEGER,
|
|
sensorTankSenderRearm
|
|
INTEGER,
|
|
sensorTankSenderDelayError
|
|
INTEGER,
|
|
sensorTankSenderDelayNormal
|
|
INTEGER,
|
|
sensorTankSenderDelayLowCritical
|
|
INTEGER,
|
|
sensorTankSenderDelayLowWarning
|
|
INTEGER,
|
|
sensorTankSenderDelayHighWarning
|
|
INTEGER,
|
|
sensorTankSenderDelayHighCritical
|
|
INTEGER,
|
|
sensorTankSenderRaw
|
|
INTEGER,
|
|
sensorTankSenderDeviceIndex
|
|
INTEGER,
|
|
sensorTankSenderDisplayStyle
|
|
INTEGER,
|
|
sensorTankSenderHighCriticalDesc
|
|
DisplayString,
|
|
sensorTankSenderLowCriticalDesc
|
|
DisplayString,
|
|
sensorTankSenderNormalDesc
|
|
DisplayString,
|
|
sensorTankSenderLowWarningDesc
|
|
DisplayString,
|
|
sensorTankSenderHighWarningDesc
|
|
DisplayString,
|
|
sensorTankSenderSensorErrorDesc
|
|
DisplayString,
|
|
sensorTankSenderHighCriticalColor
|
|
INTEGER,
|
|
sensorTankSenderLowCriticalColor
|
|
INTEGER,
|
|
sensorTankSenderNormalColor
|
|
INTEGER,
|
|
sensorTankSenderLowWarningColor
|
|
INTEGER,
|
|
sensorTankSenderHighWarningColor
|
|
INTEGER,
|
|
sensorTankSenderSensorErrorColor
|
|
INTEGER
|
|
}
|
|
|
|
sensorTankSenderIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The index into the sensor table"
|
|
::= { sensorTankSenderEntry 1 }
|
|
|
|
sensorTankSenderDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Description of this sensor"
|
|
::= { sensorTankSenderEntry 2 }
|
|
|
|
sensorTankSenderValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The reading value in this sensor"
|
|
::= { sensorTankSenderEntry 4 }
|
|
|
|
sensorTankSenderUnit OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unit string"
|
|
::= { sensorTankSenderEntry 5 }
|
|
|
|
sensorTankSenderStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highWarning(3),
|
|
highCritical(4),
|
|
lowWarning(5),
|
|
lowCritical(6),
|
|
sensorError(7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this Sensor"
|
|
::= { sensorTankSenderEntry 6 }
|
|
|
|
sensorTankSenderGoOffline OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
online(1),
|
|
goOffline(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"To take offline enter a 2"
|
|
::= { sensorTankSenderEntry 8 }
|
|
|
|
sensorTankSenderLowCritical OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Level value of this sensor gets before it sends a critical event"
|
|
::= { sensorTankSenderEntry 9 }
|
|
|
|
sensorTankSenderLowWarning OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Level value of this sensor gets before it sends a warning"
|
|
::= { sensorTankSenderEntry 10 }
|
|
|
|
sensorTankSenderHighWarning OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Level value of this sensor gets before it sends a warning"
|
|
::= { sensorTankSenderEntry 11 }
|
|
|
|
sensorTankSenderHighCritical OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Level value of this sensor gets before it sends a critical event"
|
|
::= { sensorTankSenderEntry 12 }
|
|
|
|
sensorTankSenderRearm OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of degrees to rearm the status. For example if status goes from normal to warning, the temp must go down spTempRearm degrees below warning before the status goes to normal"
|
|
::= { sensorTankSenderEntry 13 }
|
|
|
|
sensorTankSenderDelayError OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time in seconds after the sensor has been in error status before report as an error"
|
|
::= { sensorTankSenderEntry 14 }
|
|
|
|
sensorTankSenderDelayNormal OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time in seconds after the sensor change from error to normal before report as normal"
|
|
::= { sensorTankSenderEntry 15 }
|
|
|
|
sensorTankSenderDelayLowCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Low Critical before accepting new Status."
|
|
::= { sensorTankSenderEntry 16 }
|
|
|
|
sensorTankSenderDelayLowWarning OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in Low Warning before accepting new Status."
|
|
::= { sensorTankSenderEntry 17 }
|
|
|
|
sensorTankSenderDelayHighWarning OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in High Warning before accepting new Status."
|
|
::= { sensorTankSenderEntry 18 }
|
|
|
|
sensorTankSenderDelayHighCritical OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Continuous time for this sensor to be in High Critical before accepting new Status."
|
|
::= { sensorTankSenderEntry 19 }
|
|
|
|
sensorTankSenderRaw OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unformatted, raw, A/D value in this sensor. Contains more resolution than the formated percentage."
|
|
::= { sensorTankSenderEntry 20 }
|
|
|
|
sensorTankSenderDeviceIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65534)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Device Index of sensor"
|
|
::= { sensorTankSenderEntry 37 }
|
|
|
|
sensorTankSenderDisplayStyle OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
basic(0),
|
|
gauge(1)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"TankSender display style"
|
|
::= { sensorTankSenderEntry 45 }
|
|
|
|
sensorTankSenderHighCriticalDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A HighCritical Description of this sensor"
|
|
::= { sensorTankSenderEntry 46 }
|
|
|
|
sensorTankSenderLowCriticalDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A LowCritical Description of this sensor"
|
|
::= { sensorTankSenderEntry 47 }
|
|
|
|
sensorTankSenderNormalDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Normal Description of this sensor"
|
|
::= { sensorTankSenderEntry 48 }
|
|
|
|
sensorTankSenderLowWarningDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A LowWarning Description of this sensor"
|
|
::= { sensorTankSenderEntry 49 }
|
|
|
|
sensorTankSenderHighWarningDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A HighWarning Description of this sensor"
|
|
::= { sensorTankSenderEntry 50 }
|
|
|
|
sensorTankSenderSensorErrorDesc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A SensorError Description of this sensor"
|
|
::= { sensorTankSenderEntry 51 }
|
|
|
|
sensorTankSenderHighCriticalColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A HighCritical Color of this sensor"
|
|
::= { sensorTankSenderEntry 54 }
|
|
|
|
sensorTankSenderLowCriticalColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A LowCritical Color of this sensor"
|
|
::= { sensorTankSenderEntry 55 }
|
|
|
|
sensorTankSenderNormalColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A Normal Color of this sensor"
|
|
::= { sensorTankSenderEntry 56 }
|
|
|
|
sensorTankSenderLowWarningColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A LowWarning Color of this sensor"
|
|
::= { sensorTankSenderEntry 57 }
|
|
|
|
sensorTankSenderHighWarningColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A HighWarning Color of this sensor"
|
|
::= { sensorTankSenderEntry 58 }
|
|
|
|
sensorTankSenderSensorErrorColor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A SensorError Color of this sensor"
|
|
::= { sensorTankSenderEntry 59 }
|
|
|
|
--/* End of sensorTankSenderEntry */
|
|
|
|
--
|
|
-- Varbinds used in TRAP Definitions
|
|
--
|
|
|
|
sensorProbeTraps OBJECT IDENTIFIER ::= { sensorProbe 7 }
|
|
|
|
spSensorStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noStatus(1),
|
|
normal(2),
|
|
highWarning(3),
|
|
highCritical(4),
|
|
lowWarning(5),
|
|
lowCritical(6),
|
|
sensorError(7),
|
|
turnOn(8),
|
|
turnOff(9)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current integer status of the sensor causing this trap to be sent"
|
|
::= { sensorProbeTraps 1 }
|
|
|
|
spSensorValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current integer value of the sensor causing this trap to be sent"
|
|
::= { sensorProbeTraps 2 }
|
|
|
|
spSensorLevelExceeded OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The integer level that was exceeded causing this trap to be sent"
|
|
::= { sensorProbeTraps 3 }
|
|
|
|
|
|
spSensorIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The integer index of the sensor causing this trap to be sent"
|
|
::= { sensorProbeTraps 4 }
|
|
|
|
|
|
spSensorName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the sensor causing this trap to be sent"
|
|
::= { sensorProbeTraps 5 }
|
|
|
|
spSensorDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The description of the sensor causing this trap to be sent"
|
|
::= { sensorProbeTraps 6 }
|
|
|
|
spSensorProbeKeepAlive OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Keep alive trap to be sent"
|
|
::= { sensorProbeTraps 7 }
|
|
|
|
spSensorType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
temperature(1),
|
|
fourTo20mA(2),
|
|
humidity(3),
|
|
water(4),
|
|
atod(5),
|
|
security(6),
|
|
airflow(8),
|
|
siren(9),
|
|
dryContact(10),
|
|
voltage(12),
|
|
relay(13),
|
|
motion(14),
|
|
extradrycontact(16),
|
|
thermostat(23),
|
|
smoke(24),
|
|
power(25),
|
|
irms(26),
|
|
vrms(27),
|
|
watt(28),
|
|
relayarray(29),
|
|
virtual(30),
|
|
watthour(32),
|
|
temperaturearray(33),
|
|
waterrope(34),
|
|
fuellevel(35),
|
|
tanksender(36),
|
|
sound(128),
|
|
softwaremotion(129),
|
|
nosignal(132),
|
|
powermeter(134)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Type of this sensor"
|
|
::= { sensorProbeTraps 8 }
|
|
|
|
spSensorStatusName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of the sensor causing this trap to be sent"
|
|
::= { sensorProbeTraps 9 }
|
|
|
|
spSensorSubIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The integer sub index of the sensor causing this trap to be sent. Only for temperaturearray and relayarray"
|
|
::= { sensorProbeTraps 10 }
|
|
|
|
spBoardIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The integer index of the sensor board causing this trap to be sent."
|
|
::= { sensorProbeTraps 11 }
|
|
|
|
spBoardDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The description of the sensor board causing this trap to be sent"
|
|
::= { sensorProbeTraps 12 }
|
|
|
|
spEventTimeStamp OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The time(MM/DD/YYYY HH:MM:SS) of an event causing this trap to be sent"
|
|
::= { sensorProbeTraps 13 }
|
|
|
|
spEventClassNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined class number associated with this trap"
|
|
::= { sensorProbeTraps 14 }
|
|
|
|
spEventClassName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user-defined class Name associated with this trap"
|
|
::= { sensorProbeTraps 15 }
|
|
|
|
spSensorDecimalValue OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current decimal value of the sensor causing this trap to be sent"
|
|
::= { sensorProbeTraps 16 }
|
|
|
|
spSensorAliveHigh OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The highest sensor value in the period"
|
|
::= { sensorProbeTraps 17 }
|
|
|
|
spSensorAliveLow OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The lowset sensor value in the period"
|
|
::= { sensorProbeTraps 18 }
|
|
|
|
-- TRAP Definitions
|
|
|
|
spNormalStatus TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
DESCRIPTION
|
|
"sensorProbe status is Normal"
|
|
--#TYPE "sensorProbe Normal Status"
|
|
--#SEVERITY INFORMATIONAL
|
|
::= 1
|
|
|
|
spWarningStatus TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
DESCRIPTION
|
|
"sensorProbe status went to Warning"
|
|
--#TYPE "sensorProbe Warning Status"
|
|
--#SEVERITY MINOR
|
|
::= 2
|
|
|
|
spCriticalStatus TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
DESCRIPTION
|
|
"sensorProbe status went to Critical"
|
|
--#TYPE "sensorProbe Critical Status"
|
|
--#SEVERITY MAJOR
|
|
::= 3
|
|
|
|
spDownStatus TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
DESCRIPTION
|
|
"sensorProbe status went to Disabled"
|
|
--#TYPE "sensorProbe Down Status"
|
|
--#SEVERITY MINOR
|
|
::= 4
|
|
|
|
spKeepAliveTrap TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
DESCRIPTION
|
|
"sensorProbe send keep alive trap."
|
|
--#SEVERITY INFORMATIONAL
|
|
::= 5
|
|
|
|
spUnknownStatus TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
DESCRIPTION
|
|
"sensorProbe status went to Unknown"
|
|
--#TYPE "sensorProbe Unknown Status"
|
|
--#SEVERITY INFORMATIONAL
|
|
::= 7
|
|
|
|
-- sensorProbeTrapType = generalTypeTrap(2)
|
|
|
|
spTemperatureStatus TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 10
|
|
|
|
spTemperatureArray1Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 11
|
|
|
|
spTemperatureArray2Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 12
|
|
|
|
spTemperatureArray3Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 13
|
|
|
|
spTemperatureArray4Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 14
|
|
|
|
spTemperatureArray5Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 15
|
|
|
|
spTemperatureArray6Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 16
|
|
|
|
spTemperatureArray7Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 17
|
|
|
|
spTemperatureArray8Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 18
|
|
|
|
spAnalogueStatus TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Analogue Sensor Type"
|
|
--#SEVERITY MAJOR
|
|
::= 20
|
|
|
|
spSwitchStatus TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 30
|
|
|
|
spIRMSStatus TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"IRMS sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 40
|
|
|
|
spVRMSStatus TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"VRMS sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 50
|
|
|
|
spWattStatus TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Energy sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 60
|
|
|
|
spRelayArray1Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray1 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 71
|
|
|
|
spRelayArray2Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray2 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 72
|
|
|
|
spRelayArray3Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray3 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 73
|
|
|
|
spRelayArray4Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray4 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 74
|
|
|
|
spRelayArray5Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray5 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 75
|
|
|
|
spRelayArray6Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray6 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 77
|
|
|
|
spRelayArray8Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray8 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 78
|
|
|
|
spVirtualStatus TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Virtual sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 80
|
|
|
|
-- sensorProbeTrapType = statusTypeTraps(4)
|
|
|
|
spSenUnknownStatus TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"sensorProbe sensor status went to Unknown"
|
|
--#TYPE "sensorProbe Unknown Status"
|
|
--#SUMMARY "%s(%s) Status is now %d on port %d."
|
|
--#ARGUMENTS {4,5,1,3}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 4
|
|
::= 51
|
|
|
|
spSenNormalStatus TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"sensorProbe sensor status is Normal"
|
|
--#TYPE "sensorProbe Normal Status"
|
|
--#SUMMARY "%s(%s) Status is now %d on port %d."
|
|
--#ARGUMENTS {4,5,1,3}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 4
|
|
::= 52
|
|
|
|
spSenWarningStatus TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"sensorProbe sensor status went to Warning"
|
|
--#TYPE "sensorProbe Warning Status"
|
|
--#SUMMARY "%s(%s) Status is now %d on port %d."
|
|
--#ARGUMENTS {4,5,1,3}
|
|
--#SEVERITY MINOR
|
|
--#TIMEINDEX 4
|
|
::= 53
|
|
|
|
spSenCriticalStatus TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"sensorProbe sensor status went to Critical"
|
|
--#TYPE "sensorProbe Critical Status"
|
|
--#SUMMARY "%s(%s) Status is now %d on port %d."
|
|
--#ARGUMENTS {4,5,1,3}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 4
|
|
::= 54
|
|
|
|
spSenDownStatus TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"sensorProbe sensor status went to Disabled"
|
|
--#TYPE "sensorProbe Down Status"
|
|
--#SUMMARY "%s(%s) Status is now %d on port %d."
|
|
--#ARGUMENTS {4,5,1,3}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 4
|
|
::= 55
|
|
|
|
-- sensorProbeTrapType = specificTypeTrap(1)
|
|
|
|
spTemperature1Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 101
|
|
|
|
spTemperature2Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 102
|
|
|
|
spTemperature3Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 103
|
|
|
|
spTemperature4Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 104
|
|
|
|
spTemperature5Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 105
|
|
|
|
spTemperature6Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 106
|
|
|
|
spTemperature7Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 107
|
|
|
|
spTemperature8Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 108
|
|
|
|
|
|
|
|
spTemperatureArray1-1Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 111
|
|
|
|
spTemperatureArray1-2Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 112
|
|
|
|
spTemperatureArray1-3Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 113
|
|
|
|
spTemperatureArray1-4Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 114
|
|
|
|
spTemperatureArray1-5Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 115
|
|
|
|
spTemperatureArray1-6Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 116
|
|
|
|
spTemperatureArray1-7Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 117
|
|
|
|
spTemperatureArray1-8Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 118
|
|
|
|
|
|
|
|
spTemperatureArray2-1Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 121
|
|
|
|
spTemperatureArray2-2Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 122
|
|
|
|
spTemperatureArray2-3Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 123
|
|
|
|
spTemperatureArray2-4Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 124
|
|
|
|
spTemperatureArray2-5Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 125
|
|
|
|
spTemperatureArray2-6Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 126
|
|
|
|
spTemperatureArray2-7Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 127
|
|
|
|
spTemperatureArray2-8Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 128
|
|
|
|
|
|
|
|
spTemperatureArray3-1Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 131
|
|
|
|
spTemperatureArray3-2Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 132
|
|
|
|
spTemperatureArray3-3Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 133
|
|
|
|
spTemperatureArray3-4Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 134
|
|
|
|
spTemperatureArray3-5Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 135
|
|
|
|
spTemperatureArray3-6Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 136
|
|
|
|
spTemperatureArray3-7Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 137
|
|
|
|
spTemperatureArray3-8Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 138
|
|
|
|
|
|
|
|
spTemperatureArray4-1Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 141
|
|
|
|
spTemperatureArray4-2Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 142
|
|
|
|
spTemperatureArray4-3Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 143
|
|
|
|
spTemperatureArray4-4Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 144
|
|
|
|
spTemperatureArray4-5Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 145
|
|
|
|
spTemperatureArray4-6Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 146
|
|
|
|
spTemperatureArray4-7Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 147
|
|
|
|
spTemperatureArray4-8Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 148
|
|
|
|
|
|
|
|
spTemperatureArray5-1Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 151
|
|
|
|
spTemperatureArray5-2Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 152
|
|
|
|
spTemperatureArray5-3Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 153
|
|
|
|
spTemperatureArray5-4Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 154
|
|
|
|
spTemperatureArray5-5Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 155
|
|
|
|
spTemperatureArray5-6Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 156
|
|
|
|
spTemperatureArray5-7Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 157
|
|
|
|
spTemperatureArray5-8Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 158
|
|
|
|
|
|
|
|
spTemperatureArray6-1Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 161
|
|
|
|
spTemperatureArray6-2Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 162
|
|
|
|
spTemperatureArray6-3Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 163
|
|
|
|
spTemperatureArray6-4Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 164
|
|
|
|
spTemperatureArray6-5Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 165
|
|
|
|
spTemperatureArray6-6Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 166
|
|
|
|
spTemperatureArray6-7Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 167
|
|
|
|
spTemperatureArray6-8Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 168
|
|
|
|
|
|
|
|
spTemperatureArray7-1Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 171
|
|
|
|
spTemperatureArray7-2Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 172
|
|
|
|
spTemperatureArray7-3Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 173
|
|
|
|
spTemperatureArray7-4Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 174
|
|
|
|
spTemperatureArray7-5Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 175
|
|
|
|
spTemperatureArray7-6Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 176
|
|
|
|
spTemperatureArray7-7Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 177
|
|
|
|
spTemperatureArray7-8Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 178
|
|
|
|
|
|
|
|
spTemperatureArray8-1Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 181
|
|
|
|
spTemperatureArray8-2Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 182
|
|
|
|
spTemperatureArray8-3Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 183
|
|
|
|
spTemperatureArray8-4Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 184
|
|
|
|
spTemperatureArray8-5Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 185
|
|
|
|
spTemperatureArray8-6Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 186
|
|
|
|
spTemperatureArray8-7Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 187
|
|
|
|
spTemperatureArray8-8Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Temperature sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 188
|
|
|
|
|
|
|
|
spAnalogue1Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Analogue Sensor Type"
|
|
--#SEVERITY MAJOR
|
|
::= 201
|
|
|
|
spAnalogue2Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Analogue Sensor Type"
|
|
--#SEVERITY MAJOR
|
|
::= 202
|
|
|
|
spAnalogue3Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Analogue Sensor Type"
|
|
--#SEVERITY MAJOR
|
|
::= 203
|
|
|
|
spAnalogue4Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Analogue Sensor Type"
|
|
--#SEVERITY MAJOR
|
|
::= 204
|
|
|
|
spAnalogue5Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Analogue Sensor Type"
|
|
--#SEVERITY MAJOR
|
|
::= 205
|
|
|
|
spAnalogue6Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Analogue Sensor Type"
|
|
--#SEVERITY MAJOR
|
|
::= 206
|
|
|
|
spAnalogue7Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Analogue Sensor Type"
|
|
--#SEVERITY MAJOR
|
|
::= 207
|
|
|
|
spAnalogue8Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Analogue Sensor Type"
|
|
--#SEVERITY MAJOR
|
|
::= 208
|
|
|
|
|
|
|
|
spSwitch1Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 301
|
|
|
|
spSwitch2Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 302
|
|
|
|
spSwitch3Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 303
|
|
|
|
spSwitch4Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 304
|
|
|
|
spSwitch5Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 305
|
|
|
|
spSwitch6Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 306
|
|
|
|
spSwitch7Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 307
|
|
|
|
spSwitch8Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 308
|
|
|
|
spSwitch9Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 309
|
|
|
|
spSwitch10Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 310
|
|
|
|
spSwitch11Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 311
|
|
|
|
spSwitch12Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 312
|
|
|
|
spSwitch13Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 313
|
|
|
|
spSwitch14Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 314
|
|
|
|
spSwitch15Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 315
|
|
|
|
spSwitch16Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 316
|
|
|
|
spSwitch17Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 317
|
|
|
|
spSwitch18Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 318
|
|
|
|
spSwitch19Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 319
|
|
|
|
spSwitch20Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 320
|
|
|
|
spSwitch21Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 321
|
|
|
|
spSwitch22Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 322
|
|
|
|
spSwitch23Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 323
|
|
|
|
spSwitch24Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 324
|
|
|
|
spSwitch25Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 325
|
|
|
|
spSwitch26Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 326
|
|
|
|
spSwitch27Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 327
|
|
|
|
spSwitch28Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 328
|
|
|
|
spSwitch29Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 329
|
|
|
|
spSwitch30Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 330
|
|
|
|
spSwitch31Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 331
|
|
|
|
spSwitch32Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 332
|
|
|
|
spSwitch33Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 333
|
|
|
|
spSwitch34Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 334
|
|
|
|
spSwitch35Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 335
|
|
|
|
spSwitch36Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 336
|
|
|
|
spSwitch37Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 337
|
|
|
|
spSwitch38Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 338
|
|
|
|
spSwitch39Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 339
|
|
|
|
spSwitch40Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 340
|
|
|
|
spSwitch41Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 341
|
|
|
|
spSwitch42Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 342
|
|
|
|
spSwitch43Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 343
|
|
|
|
spSwitch44Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 344
|
|
|
|
spSwitch45Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 345
|
|
|
|
spSwitch46Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 346
|
|
|
|
spSwitch47Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 347
|
|
|
|
spSwitch48Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 348
|
|
|
|
spSwitch49Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 349
|
|
|
|
spSwitch50Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 350
|
|
|
|
spSwitch51Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 351
|
|
|
|
spSwitch52Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 352
|
|
|
|
spSwitch53Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 353
|
|
|
|
spSwitch54Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 354
|
|
|
|
spSwitch55Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 355
|
|
|
|
spSwitch56Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 356
|
|
|
|
spSwitch57Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 357
|
|
|
|
spSwitch58Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 358
|
|
|
|
spSwitch59Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 359
|
|
|
|
spSwitch60Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 360
|
|
|
|
spSwitch61Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 361
|
|
|
|
spSwitch62Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 362
|
|
|
|
spSwitch63Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 363
|
|
|
|
spSwitch64Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 364
|
|
|
|
spSwitch65Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 365
|
|
|
|
spSwitch66Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 366
|
|
|
|
spSwitch67Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 367
|
|
|
|
spSwitch68Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Switch sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 368
|
|
|
|
spIRMS1Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"IRMS sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 401
|
|
|
|
spIRMS2Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"IRMS sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 402
|
|
|
|
spIRMS3Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"IRMS sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 403
|
|
|
|
spIRMS4Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"IRMS sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 404
|
|
|
|
spIRMS5Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"IRMS sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 405
|
|
|
|
spIRMS6Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"IRMS sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 406
|
|
|
|
spIRMS7Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"IRMS sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 407
|
|
|
|
spIRMS8Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"IRMS sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 408
|
|
|
|
spVRMS1Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"VRMS sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 501
|
|
|
|
spVRMS2Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"VRMS sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 502
|
|
|
|
spVRMS3Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"VRMS sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 503
|
|
|
|
spVRMS4Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"VRMS sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 504
|
|
|
|
spVRMS5Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"VRMS sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 505
|
|
|
|
spVRMS6Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"VRMS sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 506
|
|
|
|
spVRMS7Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"VRMS sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 507
|
|
|
|
spVRMS8Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"VRMS sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 508
|
|
|
|
spEnergy1Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Energy sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 601
|
|
|
|
spEnergy2Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Energy sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 602
|
|
|
|
spEnergy3Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Energy sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 603
|
|
|
|
spEnergy4Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Energy sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 604
|
|
|
|
spEnergy5Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Energy sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 605
|
|
|
|
spEnergy6Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Energy sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 606
|
|
|
|
spEnergy7Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Energy sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 607
|
|
|
|
spEnergy8Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Energy sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 608
|
|
|
|
spRelayArray1-1Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray1.1 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 711
|
|
|
|
spRelayArray1-2Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray1.2 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 712
|
|
|
|
spRelayArray1-3Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray1.3 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 713
|
|
|
|
spRelayArray1-4Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray1.4 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 714
|
|
|
|
spRelayArray1-5Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray1.5 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 715
|
|
|
|
spRelayArray1-6Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray1.6 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 716
|
|
|
|
spRelayArray1-7Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray1.7 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 717
|
|
|
|
spRelayArray1-8Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray1.8 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 718
|
|
|
|
spRelayArray2-1Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray2.1 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 721
|
|
|
|
spRelayArray2-2Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray2.2 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 722
|
|
|
|
spRelayArray2-3Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray2.3 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 723
|
|
|
|
spRelayArray2-4Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray2.4 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 724
|
|
|
|
spRelayArray2-5Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray2.5 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 725
|
|
|
|
spRelayArray2-6Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray2.6 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 726
|
|
|
|
spRelayArray2-7Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray2.7 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 727
|
|
|
|
spRelayArray2-8Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray2.8 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 728
|
|
|
|
spRelayArray3-1Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray3.1 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 731
|
|
|
|
spRelayArray3-2Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray3.2 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 732
|
|
|
|
spRelayArray3-3Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray3.3 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 733
|
|
|
|
spRelayArray3-4Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray3.4 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 734
|
|
|
|
spRelayArray3-5Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray3.5 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 735
|
|
|
|
spRelayArray3-6Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray3.6 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 736
|
|
|
|
spRelayArray3-7Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray3.7 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 737
|
|
|
|
spRelayArray3-8Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray3.8 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 738
|
|
|
|
spRelayArray4-1Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray4.1 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 741
|
|
|
|
spRelayArray4-2Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray4.2 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 742
|
|
|
|
spRelayArray4-3Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray4.3 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 743
|
|
|
|
spRelayArray4-4Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray4.4 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 744
|
|
|
|
spRelayArray4-5Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray4.5 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 745
|
|
|
|
spRelayArray4-6Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray4.6 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 746
|
|
|
|
spRelayArray4-7Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray4.7 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 747
|
|
|
|
spRelayArray4-8Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray4.8 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 748
|
|
|
|
spRelayArray5-1Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray5.1 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 751
|
|
|
|
spRelayArray5-2Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray5.2 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 752
|
|
|
|
spRelayArray5-3Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray5.3 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 753
|
|
|
|
spRelayArray5-4Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray5.4 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 754
|
|
|
|
spRelayArray5-5Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray5.5 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 755
|
|
|
|
spRelayArray5-6Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray5.6 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 756
|
|
|
|
spRelayArray5-7Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray5.7 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 757
|
|
|
|
spRelayArray5-8Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray5.8 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 758
|
|
|
|
spRelayArray6-1Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray6.1 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 761
|
|
|
|
spRelayArray6-2Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray6.2 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 762
|
|
|
|
spRelayArray6-3Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray6.3 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 763
|
|
|
|
spRelayArray6-4Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray6.4 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 764
|
|
|
|
spRelayArray6-5Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray6.5 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 765
|
|
|
|
spRelayArray6-6Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray6.6 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 766
|
|
|
|
spRelayArray6-7Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray6.7 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 767
|
|
|
|
spRelayArray6-8Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray6.8 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 768
|
|
|
|
spRelayArray7-1Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray7.1 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 771
|
|
|
|
spRelayArray7-2Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray7.2 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 772
|
|
|
|
spRelayArray7-3Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray7.3 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 773
|
|
|
|
spRelayArray7-4Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray7.4 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 774
|
|
|
|
spRelayArray7-5Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray7.5 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 775
|
|
|
|
spRelayArray7-6Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray7.6 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 776
|
|
|
|
spRelayArray7-7Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray7.7 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 777
|
|
|
|
spRelayArray7-8Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray7.8 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 778
|
|
|
|
spRelayArray8-1Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray8.1 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 781
|
|
|
|
spRelayArray8-2Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray8.2 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 782
|
|
|
|
spRelayArray8-3Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray8.3 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 783
|
|
|
|
spRelayArray8-4Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray8.4 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 784
|
|
|
|
spRelayArray8-5Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray8.5 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 785
|
|
|
|
spRelayArray8-6Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray8.6 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 786
|
|
|
|
spRelayArray8-7Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray8.7 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 787
|
|
|
|
spRelayArray8-8Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"RelayArray8.8 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 788
|
|
|
|
spVirtual1Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Virtual1 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 801
|
|
|
|
spVirtual2Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Virtual2 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 802
|
|
|
|
spVirtual3Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Virtual3 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 803
|
|
|
|
spVirtual4Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Virtual4 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 804
|
|
|
|
spVirtual5Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Virtual5 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 805
|
|
|
|
spVirtual6Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Virtual6 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 806
|
|
|
|
spVirtual7Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Virtual7 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 807
|
|
|
|
spVirtual8Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Virtual8 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 808
|
|
|
|
spVirtual9Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Virtual9 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 809
|
|
|
|
spVirtual10Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Virtual10 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 810
|
|
|
|
spVirtual11Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Virtual11 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 811
|
|
|
|
spVirtual12Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Virtual12 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 812
|
|
|
|
spVirtual13Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Virtual13 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 813
|
|
|
|
spVirtual14Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Virtual14 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 814
|
|
|
|
spVirtual15Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Virtual15 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 815
|
|
|
|
spVirtual16Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Virtual16 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 816
|
|
|
|
spVirtual17Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Virtual17 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 817
|
|
|
|
spVirtual18Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Virtual18 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 818
|
|
|
|
spVirtual19Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Virtual19 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 819
|
|
|
|
spVirtual20Status TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription }
|
|
DESCRIPTION
|
|
"Virtual20 sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 820
|
|
|
|
spCustomStatus TRAP-TYPE
|
|
ENTERPRISE sensorProbe
|
|
VARIABLES
|
|
{ spSensorStatus, spSensorValue, spSensorLevelExceeded,
|
|
spSensorIndex, spSensorName, spSensorDescription,
|
|
spSensorType, spSensorStatusName, spSensorSubIndex,
|
|
spBoardIndex, spBoardDescription, spEventTimeStamp,
|
|
spEventClassNumber, spEventClassName }
|
|
DESCRIPTION
|
|
"Custom sensor trap"
|
|
--#SEVERITY MAJOR
|
|
::= 1000
|
|
|
|
END
|