IEEE8021-CFM-V2-MIB DEFINITIONS ::= BEGIN
-- ******************************************************************
-- IEEE P802.1ag(TM) CFM MIB
-- ******************************************************************
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
Unsigned32 FROM SNMPv2-SMI -- [RFC2578]
RowStatus,
TruthValue, MacAddress
FROM SNMPv2-TC -- [RFC2579]
MODULE-COMPLIANCE,
OBJECT-GROUP
FROM SNMPv2-CONF -- [RFC2580]
InterfaceIndex
FROM IF-MIB -- [RFC2863]
IEEE8021ServiceSelectorType,
IEEE8021ServiceSelectorValue,
IEEE8021ServiceSelectorValueOrNone,
IEEE8021PbbComponentIdentifier,
ieee802dot1mibs FROM IEEE8021-TC-MIB
--cfm types
Dot1agCfmMhfCreation,
Dot1agCfmIdPermission,
Dot1agCfmMDLevel,
Dot1agCfmMpDirection,
Dot1agCfmMepIdOrZero,
Dot1agCfmMDLevelOrNone,
Dot1agCfmConfigErrors,
-- cfm indexes
dot1agCfmMdIndex,
dot1agCfmMaIndex,
--cfm groups
dot1agCfmStack,
dot1agCfmDefaultMd,
dot1agCfmVlan,
dot1agCfmConfigErrorList,
dot1agCfmMa,
-- cfm row items
dot1agCfmMepLbrBadMsdu,
dot1agCfmMdRowStatus,
dot1agCfmMaNetRowStatus,
dot1agCfmMaMepListRowStatus,
dot1agCfmMepRowStatus,
--cfm conformance groups
dot1agCfmCompliances,
dot1agCfmGroups,
dot1agCfmMdGroup,
dot1agCfmMepGroup,
dot1agCfmMepDbGroup,
dot1agCfmNotificationsGroup,
ieee8021CfmDefaultMdDefGroup,
ieee8021CfmMaNetGroup FROM IEEE8021-CFM-MIB
;
ieee8021CfmV2Mib MODULE-IDENTITY
LAST-UPDATED "200810150000Z" -- October 15, 2008
ORGANIZATION "IEEE 802.1 Working Group"
CONTACT-INFO
"WG-URL: http://grouper.ieee.org/groups/802/1/index.html
WG-EMail: stds-802-1@ieee.org
Contact: David Elie-Dit-Cosaque
Alcatel-Lucent
3400 W. Plano Pkwy.
Plano, TX 75075, USA
E-mail: david.elie_dit_cosaque@alcatel-lucent.com
Contact: Norman Finn
Cisco Systems
170 W. Tasman Drive
San Jose, CA 95134, USA
E-mail: nfinn@cisco.com
Contact: David Levi
4655 GREAT AMERICA PARKWAY
SANTA CLARA, CA 95054, USA
Tel: +1-408-495-5138
E-mail: dlevi@nortel.com
"
DESCRIPTION
"Connectivity Fault Management V2 module for
managing IEEE 802.1ag-2007.
Unless otherwise indicated, the references in this MIB
module are to IEEE 802.1Q-2005 as amended by IEEE 802.1ad,
IEEE 802.1ak, IEEE 802.1ag and IEEE 802.1ah.
Copyright (C) IEEE.
This version of this MIB module is part of IEEE802.1Q;
see the draft itself for full legal notices."
REVISION "200810150000Z" -- October 15, 2008
DESCRIPTION
"The IEEE8021-CFM-V2-MIB Module contains objects that
replace those deprecated in the IEEE8021-CFM-MIB module.
This version is included in IEEE 802.1ap"
::= { ieee802dot1mibs 7 }
-- ******************************************************************
-- Note: Re-indexed 802.1ag tables
-- ******************************************************************
-- This section contains new tables replacing deprecated tables in
-- this version of the MIB
-- ******************************************************************
-- The CFM Stack Table
-- ******************************************************************
ieee8021CfmStackTable OBJECT-TYPE
SYNTAX SEQUENCE OF Ieee8021CfmStackEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"There is one CFM Stack table per bridge. It permits
the retrieval of information about the Maintenance Points
configured on any given interface.
"
REFERENCE
"12.14.2"
::= { dot1agCfmStack 2 }
ieee8021CfmStackEntry OBJECT-TYPE
SYNTAX Ieee8021CfmStackEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Stack table entry."
INDEX { ieee8021CfmStackifIndex, ieee8021CfmStackServiceSelectorType,
ieee8021CfmStackServiceSelectorOrNone,
ieee8021CfmStackMdLevel, ieee8021CfmStackDirection
}
::= { ieee8021CfmStackTable 1 }
Ieee8021CfmStackEntry ::= SEQUENCE {
ieee8021CfmStackifIndex InterfaceIndex,
ieee8021CfmStackServiceSelectorType IEEE8021ServiceSelectorType,
ieee8021CfmStackServiceSelectorOrNone IEEE8021ServiceSelectorValueOrNone,
ieee8021CfmStackMdLevel Dot1agCfmMDLevel,
ieee8021CfmStackDirection Dot1agCfmMpDirection,
ieee8021CfmStackMdIndex Unsigned32,
ieee8021CfmStackMaIndex Unsigned32,
ieee8021CfmStackMepId Dot1agCfmMepIdOrZero,
ieee8021CfmStackMacAddress MacAddress
}
ieee8021CfmStackifIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object represents the Bridge Port or aggregated port
on which MEPs or MHFs might be configured.
Upon a restart of the system, the system SHALL, if necessary,
change the value of this variable, and rearrange the
ieee8021CfmStackTable, so that it indexes the entry in the
interface table with the same value of ifAlias that it
indexed before the system restart. If no such entry exists,
then the system SHALL delete all entries in the
ieee8021CfmStackTable with the interface index.
"
REFERENCE
"12.14.2.1.2:a"
::= { ieee8021CfmStackEntry 1 }
ieee8021CfmStackServiceSelectorType OBJECT-TYPE
SYNTAX IEEE8021ServiceSelectorType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Type of the Service Selector identifier indicated by ieee8021CfmStackServiceSelectorOrNone.
See textual convention IEEE8021ServiceSelectorType for details.
"
REFERENCE
"12.14.2.1.2:d, 22.1.7"
::= { ieee8021CfmStackEntry 2 }
ieee8021CfmStackServiceSelectorOrNone OBJECT-TYPE
SYNTAX IEEE8021ServiceSelectorValueOrNone
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Service Selector identifier to which the MP is attached, or 0, if none.
See textual convention IEEE8021ServiceSelectorValue for details.
"
REFERENCE
"12.14.2.1.2:d, 22.1.7"
::= { ieee8021CfmStackEntry 3 }
ieee8021CfmStackMdLevel OBJECT-TYPE
SYNTAX Dot1agCfmMDLevel
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"MD Level of the Maintenance Point."
REFERENCE
"12.14.2.1.2:b"
::= { ieee8021CfmStackEntry 4 }
ieee8021CfmStackDirection OBJECT-TYPE
SYNTAX Dot1agCfmMpDirection
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Direction in which the MP faces on the Bridge Port.
"
REFERENCE
"12.14.2.1.2:c"
::= { ieee8021CfmStackEntry 5 }
ieee8021CfmStackMdIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the Maintenance Domain in the ieee8021CfmMdTable
to which the MP is associated, or 0, if none."
REFERENCE
"12.14.2.1.3:b"
::= { ieee8021CfmStackEntry 6 }
ieee8021CfmStackMaIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the MA in the ieee8021CfmMaNetTable and
ieee8021CfmMaCompTable to which the MP is associated, or 0, if
none."
REFERENCE
"12.14.2.1.3:c"
::= { ieee8021CfmStackEntry 7 }
ieee8021CfmStackMepId OBJECT-TYPE
SYNTAX Dot1agCfmMepIdOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If an MEP is configured, the MEPID, else 0"
REFERENCE
"12.14.2.1.3:d"
::= { ieee8021CfmStackEntry 8 }
ieee8021CfmStackMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MAC address of the MP."
REFERENCE
"12.14.2.1.3:e"
::= { ieee8021CfmStackEntry 9 }
-- ******************************************************************
-- The CFM VLAN Table
-- ******************************************************************
ieee8021CfmVlanTable OBJECT-TYPE
SYNTAX SEQUENCE OF Ieee8021CfmVlanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table defines the association of VIDs into VLANs. There
is an entry in this table, for each component of the bridge,
for each VID that is:
a) a VID belonging to a VLAN associated with more than
one VID; and
b) not the Primary VLAN of that VID.
The entry in this table contains the Primary VID of the VLAN.
By default, this table is empty, meaning that every VID is
the Primary VID of a single-VID VLAN.
VLANs that are associated with only one VID SHOULD NOT have
an entry in this table.
The writable objects in this table need to be persistent
upon reboot or restart of a device.
"
REFERENCE
"12.14.3.1.3:a, 12.14.3.2.2:a, 12.14.5.3.2:c,
12.14.6.1.3:b, 22.1.5."
::= { dot1agCfmVlan 2 }
ieee8021CfmVlanEntry OBJECT-TYPE
SYNTAX Ieee8021CfmVlanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The VLAN table entry."
INDEX { ieee8021CfmVlanComponentId,
ieee8021CfmVlanSelector}
::= { ieee8021CfmVlanTable 1 }
Ieee8021CfmVlanEntry ::= SEQUENCE {
ieee8021CfmVlanComponentId IEEE8021PbbComponentIdentifier,
ieee8021CfmVlanSelector IEEE8021ServiceSelectorValue,
ieee8021CfmVlanPrimarySelector IEEE8021ServiceSelectorValue,
ieee8021CfmVlanRowStatus RowStatus
}
ieee8021CfmVlanComponentId OBJECT-TYPE
SYNTAX IEEE8021PbbComponentIdentifier
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The bridge component within the system to which the information
in this ieee8021CfmVlanEntry applies. If the system is not a
Bridge, or if only one component is present in the Bridge, then
this variable (index) MUST be equal to 1.
"
REFERENCE
"12.3 l)"
::= { ieee8021CfmVlanEntry 1 }
ieee8021CfmVlanSelector OBJECT-TYPE
SYNTAX IEEE8021ServiceSelectorValue
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is a service ID belonging to a service that is associated
with more than one Service Selector identifiers, and this is not the Primary
Service ID of the service. The type of this Service Selector is the same
as the primary Service Selector's type defined by ieee8021CfmMaCompPrimarySelectorType
in the ieee8021CfmMaCompTable.
"
::= { ieee8021CfmVlanEntry 3 }
ieee8021CfmVlanPrimarySelector OBJECT-TYPE
SYNTAX IEEE8021ServiceSelectorValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This is the Primary Service selector for a Service that is associated
with more than one Service Selector identifiers. This value MUST not
equal the value of ieee8021CfmVlanSelector. The type of this Service Selector is the same
as the primary Service Selector's type defined by ieee8021CfmMaCompPrimarySelectorType
in the ieee8021CfmMaCompTable.
"
::= { ieee8021CfmVlanEntry 5 }
ieee8021CfmVlanRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of the row.
The writable columns in a row can not be changed if the row
is active. All columns MUST have a valid value before a row
can be activated.
"
::= { ieee8021CfmVlanEntry 6 }
-- *******************************************************************
-- The CFM Default MD Level Table
-- *******************************************************************
ieee8021CfmDefaultMdTable OBJECT-TYPE
SYNTAX SEQUENCE OF Ieee8021CfmDefaultMdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"For each bridge component, the Default MD Level Managed Object
controls MHF creation for VIDs that are not attached to a
specific Maintenance Association Managed Object, and Sender ID
TLV transmission by those MHFs.
For each Bridge Port, and for each VLAN ID whose data can
pass through that Bridge Port, an entry in this table is
used by the algorithm in subclause 22.2.3 only if there is no
entry in the Maintenance Association table defining an MA
for the same VLAN ID and MD Level as this table's entry, and
on which MA an Up MEP is defined. If there exists such an
MA, that MA's objects are used by the algorithm in
subclause 22.2.3 in place of this table entry's objects. The
agent maintains the value of ieee8021CfmDefaultMdStatus to
indicate whether this entry is overridden by an MA.
When first initialized, the agent creates this table
automatically with entries for all VLAN IDs,
with the default values specified for each object.
After this initialization, the writable objects in this
table need to be persistent upon reboot or restart of a
device.
"
REFERENCE
"12.14.3"
::= { dot1agCfmDefaultMd 5 }
ieee8021CfmDefaultMdEntry OBJECT-TYPE
SYNTAX Ieee8021CfmDefaultMdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Default MD Level table entry."
INDEX { ieee8021CfmDefaultMdComponentId,
ieee8021CfmDefaultMdPrimarySelectorType,
ieee8021CfmDefaultMdPrimarySelector}
::= { ieee8021CfmDefaultMdTable 1 }
Ieee8021CfmDefaultMdEntry ::= SEQUENCE {
ieee8021CfmDefaultMdComponentId IEEE8021PbbComponentIdentifier,
ieee8021CfmDefaultMdPrimarySelectorType IEEE8021ServiceSelectorType,
ieee8021CfmDefaultMdPrimarySelector IEEE8021ServiceSelectorValue,
ieee8021CfmDefaultMdStatus TruthValue,
ieee8021CfmDefaultMdLevel Dot1agCfmMDLevelOrNone,
ieee8021CfmDefaultMdMhfCreation Dot1agCfmMhfCreation,
ieee8021CfmDefaultMdIdPermission Dot1agCfmIdPermission
}
ieee8021CfmDefaultMdComponentId OBJECT-TYPE
SYNTAX IEEE8021PbbComponentIdentifier
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The bridge component within the system to which the information
in this ieee8021CfmDefaultMdEntry applies. If the system is not
a Bridge, or if only one component is present in the Bridge,
then this variable (index) MUST be equal to 1.
"
REFERENCE
"12.3 l)"
::= { ieee8021CfmDefaultMdEntry 1 }
ieee8021CfmDefaultMdPrimarySelectorType OBJECT-TYPE
SYNTAX IEEE8021ServiceSelectorType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Type of the Primary Service Selector identifier indicated by
ieee8021CfmDefaultMdPrimarySelector. See textual
convention IEEE8021ServiceSelectorType for details.
"
::= { ieee8021CfmDefaultMdEntry 2 }
ieee8021CfmDefaultMdPrimarySelector OBJECT-TYPE
SYNTAX IEEE8021ServiceSelectorValue
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Primary Service Selector identifier of a Service Instance with
no MA configured. See IEEE8021ServiceSelectorValue for details.
"
::= { ieee8021CfmDefaultMdEntry 3 }
ieee8021CfmDefaultMdStatus OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"State of this Default MD Level table entry. True if there is
no entry in the Maintenance Association table defining an MA
for the same VLAN ID and MD Level as this table's entry, and
on which MA an Up MEP is defined, else false.
"
REFERENCE
"12.14.3.1.3:b"
::= { ieee8021CfmDefaultMdEntry 4 }
ieee8021CfmDefaultMdLevel OBJECT-TYPE
SYNTAX Dot1agCfmMDLevelOrNone
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A value indicating the MD Level at which MHFs are to be
created, and Sender ID TLV transmission by those MHFs is to
be controlled, for the VLAN to which this entry's objects
apply. If this object has the value -1, the MD Level for MHF
creation for this VLAN is controlled by
ieee8021CfmDefaultMdDefLevel.
"
REFERENCE
"12.14.3.1.3:c, 12.14.3.2.2:b"
DEFVAL {-1}
::= { ieee8021CfmDefaultMdEntry 5 }
ieee8021CfmDefaultMdMhfCreation OBJECT-TYPE
SYNTAX Dot1agCfmMhfCreation
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A value indicating if the Management entity can create MHFs
(MIP Half Function) for this VID at this MD Level. If this
object has the value defMHFdefer, MHF creation for this VLAN
is controlled by ieee8021CfmDefaultMdDefMhfCreation.
The value of this variable is meaningless if the values of
ieee8021CfmDefaultMdStatus is false.
"
REFERENCE
"12.14.3.1.3:d"
DEFVAL {defMHFdefer}
::= { ieee8021CfmDefaultMdEntry 6 }
ieee8021CfmDefaultMdIdPermission OBJECT-TYPE
SYNTAX Dot1agCfmIdPermission
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Enumerated value indicating what, if anything, is to be
included in the Sender ID TLV (21.5.3) transmitted by MHFs
created by the Default Maintenance Domain. If this object
has the value sendIdDefer, Sender ID TLV transmission for
this VLAN is controlled by ieee8021CfmDefaultMdDefIdPermission.
The value of this variable is meaningless if the values of
ieee8021CfmDefaultMdStatus is false.
"
REFERENCE
"12.14.3.1.3:e"
DEFVAL { sendIdDefer }
::= { ieee8021CfmDefaultMdEntry 7 }
-- ******************************************************************
-- The CFM Configuration Error List Table
-- ******************************************************************
ieee8021CfmConfigErrorListTable OBJECT-TYPE
SYNTAX SEQUENCE OF Ieee8021CfmConfigErrorListEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The CFM Configuration Error List table provides a list of
Interfaces and VIDs that are incorrectly configured.
"
REFERENCE
"12.14.4"
::= {dot1agCfmConfigErrorList 2}
ieee8021CfmConfigErrorListEntry OBJECT-TYPE
SYNTAX Ieee8021CfmConfigErrorListEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Config Error List Table entry"
INDEX { ieee8021CfmConfigErrorListSelectorType,
ieee8021CfmConfigErrorListSelector,
ieee8021CfmConfigErrorListIfIndex
}
::= { ieee8021CfmConfigErrorListTable 1}
Ieee8021CfmConfigErrorListEntry ::= SEQUENCE {
ieee8021CfmConfigErrorListSelectorType IEEE8021ServiceSelectorType,
ieee8021CfmConfigErrorListSelector IEEE8021ServiceSelectorValue,
ieee8021CfmConfigErrorListIfIndex InterfaceIndex,
ieee8021CfmConfigErrorListErrorType Dot1agCfmConfigErrors
}
ieee8021CfmConfigErrorListSelectorType OBJECT-TYPE
SYNTAX IEEE8021ServiceSelectorType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Type of the Service Selector identifier indicated by
ieee8021CfmConfigErrorListSelector. See textual
convention IEEE8021ServiceSelectorType for details.
"
REFERENCE
"12.14.4.1.2:a"
::= { ieee8021CfmConfigErrorListEntry 1 }
ieee8021CfmConfigErrorListSelector OBJECT-TYPE
SYNTAX IEEE8021ServiceSelectorValue
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Service Selector Identifier of the Service with interfaces
in error. See IEEE8021ServiceSelectorValue for details.
"
REFERENCE
"12.14.4.1.2:a"
::= { ieee8021CfmConfigErrorListEntry 2 }
ieee8021CfmConfigErrorListIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object is the IfIndex of the interface.
Upon a restart of the system, the system SHALL, if necessary,
change the value of this variable so that it indexes the
entry in the interface table with the same value of ifAlias
that it indexed before the system restart. If no such
entry exists, then the system SHALL delete any entries in
ieee8021CfmConfigErrorListTable indexed by that
InterfaceIndex value.
"
REFERENCE
"12.14.4.1.2:b"
::= { ieee8021CfmConfigErrorListEntry 3 }
ieee8021CfmConfigErrorListErrorType OBJECT-TYPE
SYNTAX Dot1agCfmConfigErrors
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A vector of Boolean error conditions from 22.2.4, any of
which may be true:
0) CFMleak;
1) ConflictingVids;
2) ExcessiveLevels;
3) OverlappedLevels.
"
REFERENCE
"12.14.4.1.3:b"
::= { ieee8021CfmConfigErrorListEntry 4 }
-- ******************************************************************
-- The CFM Maintenance Association (MA) Component Table
-- ******************************************************************
ieee8021CfmMaCompTable OBJECT-TYPE
SYNTAX SEQUENCE OF Ieee8021CfmMaCompEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Maintenance Association table. Each row in the table
represents an MA. An MA is a set of MEPs, each configured
with a single service instance.
This is the part of the complete MA table that is variable
across the Bridges in a Maintenance Domain, or across the
components of a single Bridge. That part of the MA table that
is constant across the Bridges and their components in a
Maintenance Domain is contained in the ieee8021CfmMaNetTable.
This table uses three indices, first index is the
IEEE8021PbbComponentIdentifier that identifies the component
within the Bridge for which the information in the
ieee8021CfmMaCompEntry applies. The second is the index of the
Maintenance Domain table. The third index is the same as the
index of the ieee8021CfmMaNetEntry for the same MA.
The writable objects in this table need to be persistent
upon reboot or restart of a device.
"
REFERENCE
"18.2"
::= { dot1agCfmMa 4 }
ieee8021CfmMaCompEntry OBJECT-TYPE
SYNTAX Ieee8021CfmMaCompEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The MA table entry."
INDEX {ieee8021CfmMaComponentId,
dot1agCfmMdIndex, dot1agCfmMaIndex }
::= { ieee8021CfmMaCompTable 1 }
Ieee8021CfmMaCompEntry ::= SEQUENCE {
ieee8021CfmMaComponentId IEEE8021PbbComponentIdentifier,
ieee8021CfmMaCompPrimarySelectorType IEEE8021ServiceSelectorType,
ieee8021CfmMaCompPrimarySelectorOrNone IEEE8021ServiceSelectorValueOrNone,
ieee8021CfmMaCompMhfCreation Dot1agCfmMhfCreation,
ieee8021CfmMaCompIdPermission Dot1agCfmIdPermission,
ieee8021CfmMaCompNumberOfVids Unsigned32,
ieee8021CfmMaCompRowStatus RowStatus
}
ieee8021CfmMaComponentId OBJECT-TYPE
SYNTAX IEEE8021PbbComponentIdentifier
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The bridge component within the system to which the information
in this ieee8021CfmMaCompEntry applies. If the system is not a
Bridge, or if only one component is present in the Bridge, then
this variable (index) MUST be equal to 1.
"
REFERENCE
"12.3 l)"
::= { ieee8021CfmMaCompEntry 1 }
ieee8021CfmMaCompPrimarySelectorType OBJECT-TYPE
SYNTAX IEEE8021ServiceSelectorType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Type of the Service Selector identifiers indicated by
ieee8021CfmMaCompPrimarySelectorOrNone. If the service instance is defined by more
than one Service Selector, this parameter also indicates the type of the
ieee8021CfmVlanPrimarySelector and ieee8021CfmVlanSelector in the ieee8021CfmVlanTable.
In Services instances made of multiple Service Selector identifiers, ensures that the
type of the Service selector identifiers is the same. See textual convention
Dot1agCfmServiceSelectorType for details.
"
REFERENCE
"12.14.6.1.3:b"
::= { ieee8021CfmMaCompEntry 2 }
ieee8021CfmMaCompPrimarySelectorOrNone OBJECT-TYPE
SYNTAX IEEE8021ServiceSelectorValueOrNone
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Service Selector identifier to which the MP is attached, or 0, if none.
If the MA is associated with more than one Service Selectors Identifiers, the
ieee8021CfmVlanTable lists them.
"
REFERENCE
"12.14.6.1.3:b"
::= { ieee8021CfmMaCompEntry 3 }
ieee8021CfmMaCompMhfCreation OBJECT-TYPE
SYNTAX Dot1agCfmMhfCreation
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates if the Management entity can create MHFs (MIP Half
Function) for this MA.
"
REFERENCE
"12.14.6.1.3:c"
DEFVAL { defMHFdefer }
::= { ieee8021CfmMaCompEntry 4 }
ieee8021CfmMaCompIdPermission OBJECT-TYPE
SYNTAX Dot1agCfmIdPermission
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Enumerated value indicating what, if anything, is to be
included in the Sender ID TLV (21.5.3) transmitted by MPs
configured in this MA.
"
REFERENCE
"12.14.6.1.3:d"
DEFVAL { sendIdDefer }
::= { ieee8021CfmMaCompEntry 5 }
ieee8021CfmMaCompNumberOfVids OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The number of VIDs associated with the MA.
"
REFERENCE
"12.14.6.1.3:b"
::= { ieee8021CfmMaCompEntry 6 }
ieee8021CfmMaCompRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of the row.
The writable columns in a row can not be changed if the row
is active. All columns MUST have a valid value before a row
can be activated.
"
::= { ieee8021CfmMaCompEntry 7 }
-- ******************************************************************
-- Units of conformance
-- ******************************************************************
ieee8021CfmStackGroup OBJECT-GROUP
OBJECTS {
ieee8021CfmStackMdIndex,
ieee8021CfmStackMaIndex,
ieee8021CfmStackMepId,
ieee8021CfmStackMacAddress
}
STATUS current
DESCRIPTION
"Objects for the Stack group."
::= { dot1agCfmGroups 14 }
ieee8021CfmMaGroup OBJECT-GROUP
OBJECTS {
ieee8021CfmMaCompPrimarySelectorType,
ieee8021CfmMaCompPrimarySelectorOrNone,
ieee8021CfmMaCompMhfCreation,
ieee8021CfmMaCompIdPermission,
ieee8021CfmMaCompRowStatus,
ieee8021CfmMaCompNumberOfVids
}
STATUS current
DESCRIPTION
"Objects for the MA group."
::= { dot1agCfmGroups 15 }
ieee8021CfmDefaultMdGroup OBJECT-GROUP
OBJECTS {
ieee8021CfmDefaultMdStatus,
ieee8021CfmDefaultMdLevel,
ieee8021CfmDefaultMdMhfCreation,
ieee8021CfmDefaultMdIdPermission
}
STATUS current
DESCRIPTION
"Objects for the Default MD Level group."
::= { dot1agCfmGroups 16 }
ieee8021CfmVlanIdGroup OBJECT-GROUP
OBJECTS {
ieee8021CfmVlanPrimarySelector,
ieee8021CfmVlanRowStatus
}
STATUS current
DESCRIPTION
"Objects for the VLAN ID group."
::= { dot1agCfmGroups 17 }
ieee8021CfmConfigErrorListGroup OBJECT-GROUP
OBJECTS {
ieee8021CfmConfigErrorListErrorType
}
STATUS current
DESCRIPTION
"Objects for the CFM Configuration Error List Group."
::= {dot1agCfmGroups 18 }
-- ******************************************************************
-- MIB Module Compliance statements
-- ******************************************************************
ieee8021CfmComplianceV2 MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for support of the CFM MIB module."
MODULE
MANDATORY-GROUPS {
ieee8021CfmStackGroup,
ieee8021CfmMaGroup,
ieee8021CfmDefaultMdGroup,
ieee8021CfmConfigErrorListGroup
}
GROUP ieee8021CfmVlanIdGroup
DESCRIPTION "The VLAN ID group is optional."
OBJECT ieee8021CfmMaCompRowStatus
SYNTAX RowStatus { active(1), notInService(2) }
WRITE-SYNTAX RowStatus { notInService(2), createAndGo(4),
destroy(6) }
DESCRIPTION "Support for createAndWait is not required."
OBJECT ieee8021CfmVlanRowStatus
SYNTAX RowStatus { active(1), notInService(2) }
WRITE-SYNTAX RowStatus { notInService(2), createAndGo(4),
destroy(6) }
DESCRIPTION "Support for createAndWait is not required."
MODULE IEEE8021-CFM-MIB
MANDATORY-GROUPS {
dot1agCfmMdGroup,
dot1agCfmMepGroup,
dot1agCfmMepDbGroup,
dot1agCfmNotificationsGroup,
ieee8021CfmDefaultMdDefGroup,
ieee8021CfmMaNetGroup
}
OBJECT dot1agCfmMepLbrBadMsdu
MIN-ACCESS not-accessible
DESCRIPTION "The dot1agCfmMepLbrBadMsdu variable is optional. It
MUST not be present if the system cannot compare a
received LBR to the corresponding LBM."
OBJECT dot1agCfmMdRowStatus
SYNTAX RowStatus { active(1), notInService(2) }
WRITE-SYNTAX RowStatus { notInService(2), createAndGo(4),
destroy(6) }
DESCRIPTION "Support for createAndWait is not required."
OBJECT dot1agCfmMaNetRowStatus
SYNTAX RowStatus { active(1), notInService(2) }
WRITE-SYNTAX RowStatus { notInService(2), createAndGo(4),
destroy(6) }
DESCRIPTION "Support for createAndWait is not required."
OBJECT dot1agCfmMaMepListRowStatus
SYNTAX RowStatus { active(1), notInService(2) }
WRITE-SYNTAX RowStatus { notInService(2), createAndGo(4),
destroy(6) }
DESCRIPTION "Support for createAndWait is not required."
OBJECT dot1agCfmMepRowStatus
SYNTAX RowStatus { active(1), notInService(2) }
WRITE-SYNTAX RowStatus { notInService(2), createAndGo(4),
destroy(6) }
DESCRIPTION "Support for createAndWait is not required."
::= { dot1agCfmCompliances 2 }