mirror of
https://github.com/librenms/librenms.git
synced 2024-09-21 18:38:25 +00:00
11147d3bbf
* Extract DiscoveryItem and move some things to better places. Extract model class Fix up model construction. I have problem with construction... Makeshift model working. Switch constructor to factory. discover() and create() Support legacy discovery. Remove uneeded custom pollers Remove netonix custom detection as we try ucd on all os now. Add a few yaml procs. Fix a couple things. More processor discovery conversions Move Calix e7 to standard hrProcessorLoad, but it doesn't fully implement the HR-MIB, move things around to make it work. Add a few yaml procs. Fix a couple things. Correct some stupid mib stuff. Move more, drop php 5.3 Add netscaler which uses string indexes. Port fiberhome to yaml and use skip_values More conversions. BroadcomProcessorUsage Trait Serveriron and Ironware share some mibs. Create a common abstract os for them. Add yaml support for mib specification in each data entry Make legacy discover_processor() set 0 for hrDeviceIndex Untangle Dell switch OS processors Use use shared OS for groups if they don't have a specific group. fix silly mib mistake Make index optional Move HR and UCD to Traits and out of Processor. * forgot to update the fortiswitch index * Make sgos and avaya-ers match the old index. * fix comware test data * fix merge errors * fix dsm and remove pointless empty modules * file not found exception is in the wrong place. * Updated processor development docs
342 lines
12 KiB
Plaintext
342 lines
12 KiB
Plaintext
-- *********************************************************************
|
|
-- **
|
|
-- ** BATM Advanced Communications.
|
|
-- **
|
|
-- *********************************************************************
|
|
-- ** Filename: PRVT-STATISTICS-HISTORY-MIB.mib
|
|
-- ** Project: T-Metro Switches.
|
|
-- ** Purpose: Private MIB
|
|
-- *********************************************************************
|
|
-- (c) Copyright, 2009, BATM Advanced Communications. All rights reserved.
|
|
-- WARNING:
|
|
--
|
|
-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
|
|
--
|
|
-- This file is the property of BATM Advanced Communications and contains
|
|
-- proprietary and confidential information. This file is made
|
|
-- available to authorized BATM customers on the express
|
|
-- condition that neither it, nor any of the information contained
|
|
-- therein, shall be disclosed to third parties or be used for any
|
|
-- purpose other than to replace, modify or upgrade firmware and/or
|
|
-- software components of BATM manufactured equipment within the
|
|
-- authorized customer's network, and that such transfer be
|
|
-- completed in accordance with the instructions provided by
|
|
-- BATM. Any other use is strictly prohibited.
|
|
--
|
|
-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
|
|
-- WARRANTY, THE SOFTWARE PROGRAMS CONTAINED IN THIS FILE ARE
|
|
-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
|
|
-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
|
|
-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
|
|
--
|
|
-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
|
|
-- INCLUDING WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
|
|
-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
|
|
-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
|
|
-- TO USE, THE SOFTWARE CONTAINED IN THIS FILE.
|
|
--
|
|
-- ----------------------------------------------------------------------------
|
|
|
|
PRVT-STATISTICS-HISTORY-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
switch
|
|
FROM PRVT-SWITCH-MIB
|
|
MODULE-IDENTITY, OBJECT-TYPE, Unsigned32
|
|
FROM SNMPv2-SMI
|
|
RowStatus, TruthValue
|
|
FROM SNMPv2-TC;
|
|
|
|
prvtStatHistMIB MODULE-IDENTITY
|
|
LAST-UPDATED "201202200000Z"
|
|
ORGANIZATION
|
|
"BATM Advanced Communication"
|
|
CONTACT-INFO
|
|
"BATM/Telco Systems Support team
|
|
Email:
|
|
For North America: techsupport@telco.com
|
|
For North Europe: support@batm.de, info@batm.de
|
|
For the rest of the world: techsupport@telco.com"
|
|
DESCRIPTION
|
|
"This MIB provides functionallity similar to RMON2-MIB.
|
|
Instead with OIDs mib is working with XPath 1.0 strings -
|
|
http://www.w3.org/TR/xpath.
|
|
Profile tables will be initialized with currently available
|
|
statistics."
|
|
REVISION "201202200000Z"
|
|
DESCRIPTION
|
|
"Initial version"
|
|
::= { switch 180 }
|
|
|
|
|
|
prvtStatHistObjects OBJECT IDENTIFIER
|
|
::= { prvtStatHistMIB 1 }
|
|
|
|
prvtStatHistShutdown OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable/disable the statistics history on the device"
|
|
::= { prvtStatHistObjects 1 }
|
|
|
|
prvtStatHistGetInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (10..3600)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Interval in seconds at which history statistics
|
|
will be gathered. Changes of this value will take
|
|
effect after current interval is over."
|
|
::= { prvtStatHistObjects 2 }
|
|
|
|
prvtStatHistType OBJECT-TYPE
|
|
SYNTAX INTEGER { absolute(1), delta(2) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The method of sampling the selected variable.
|
|
Changes will take effect after current interval is over."
|
|
::= { prvtStatHistObjects 3 }
|
|
|
|
prvtStatHistProfileTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrvtStatHistProfileEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Create profiles with XPath 1.0 pattern."
|
|
::= { prvtStatHistObjects 4 }
|
|
|
|
prvtStatHistProfileEntry OBJECT-TYPE
|
|
SYNTAX PrvtStatHistProfileEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry in prvtStatHistProfileTable."
|
|
INDEX { prvtStatHistProfileName }
|
|
::= { prvtStatHistProfileTable 1 }
|
|
|
|
PrvtStatHistProfileEntry ::= SEQUENCE {
|
|
prvtStatHistProfileName OCTET STRING,
|
|
prvtStatHistProfileRowStatus RowStatus,
|
|
prvtStatHistProfileXPathTemplate OCTET STRING
|
|
}
|
|
|
|
prvtStatHistProfileName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..128))
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Profile identifier - string with length [ 1 .. 128 ]"
|
|
::= { prvtStatHistProfileEntry 1 }
|
|
|
|
prvtStatHistProfileRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Create rows in prvtStatHistProfileTable."
|
|
::= { prvtStatHistProfileEntry 2 }
|
|
|
|
prvtStatHistProfileXPathTemplate OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..255))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"XPath 1.0 template - contains data model path, with '{%s}' as
|
|
key place holder - if we have multiply keys more '%s' must
|
|
be added. Changes of this value will take effect
|
|
after current interval is over."
|
|
::= { prvtStatHistProfileEntry 3 }
|
|
|
|
prvtStatHistControlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrvtStatHistControlEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Control table binds profile to a keys."
|
|
::= { prvtStatHistObjects 5 }
|
|
|
|
prvtStatHistControlEntry OBJECT-TYPE
|
|
SYNTAX PrvtStatHistControlEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry in prvtStatHistControlTable."
|
|
INDEX { prvtStatHistControlId }
|
|
::= { prvtStatHistControlTable 1 }
|
|
|
|
PrvtStatHistControlEntry ::= SEQUENCE {
|
|
prvtStatHistControlId Unsigned32,
|
|
prvtStatHistControlRowStatus RowStatus,
|
|
prvtStatHistControlProfileName OCTET STRING,
|
|
prvtStatHistControlXPathKey OCTET STRING,
|
|
prvtStatHistControlValue OCTET STRING,
|
|
prvtStatHistControlFirstDataId OCTET STRING,
|
|
prvtStatHistControlLastDataId OCTET STRING
|
|
}
|
|
|
|
prvtStatHistControlId OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..200)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Control table identifier. Number [ 1 .. 200 ] "
|
|
::= { prvtStatHistControlEntry 1 }
|
|
|
|
prvtStatHistControlRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Create entry in prvtStatHistControlTable.
|
|
Changes of this value will take effect after
|
|
current interval is over."
|
|
::= { prvtStatHistControlEntry 2 }
|
|
|
|
prvtStatHistControlProfileName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..128))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Profile name from prvtStatHistProfileTable.
|
|
Changes of this value will take effect after
|
|
current interval is over."
|
|
::= { prvtStatHistControlEntry 3 }
|
|
|
|
prvtStatHistControlXPathKey OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..255))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"XPath key is applied to profile XPath-template.
|
|
Changes of this value will take effect after
|
|
current interval is over."
|
|
::= { prvtStatHistControlEntry 4 }
|
|
|
|
prvtStatHistControlValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current value of the prvtStatHistControlProfileName +
|
|
prvtStatHistControlXPathKey or empty if get operation was unsucceful.
|
|
To debug the problem, enable logs."
|
|
::= { prvtStatHistControlEntry 5 }
|
|
|
|
prvtStatHistControlFirstDataId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"prvtStatHistDataTable has maximum 120 elements.
|
|
This restriction is due to hardware limitation.
|
|
prvtStatHistControlFirstDataId will define first valid index
|
|
in prvtStatHistDataTable table thus making constantly increasing
|
|
prvtStatHistDataId more predicatable for management systems.
|
|
Value should be treated as unsigned 64 bits integer"
|
|
::= { prvtStatHistControlEntry 6 }
|
|
|
|
prvtStatHistControlLastDataId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"prvtStatHistDataTable has maximum 120 elements.
|
|
This restriction is due to hardware limitation.
|
|
prvtStatHistControlLastDataId will define last valid index
|
|
in prvtStatHistDataTable table thus making constantly increasing
|
|
prvtStatHistDataId more predicatable for management systems.
|
|
Value should be treated as unsigned 64 bits integer"
|
|
::= { prvtStatHistControlEntry 7 }
|
|
|
|
prvtStatHistDataTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrvtStatHistDataEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A historical sample of user-defined variables. This sample
|
|
is associated with the prvtStatHistControlEntry that set up the
|
|
parameters for a regular collection of these samples.
|
|
The prvtStatHistControlId value in the index identifies the
|
|
prvtStatHistControlEntry on whose behalf this entry was created."
|
|
::= { prvtStatHistObjects 6 }
|
|
|
|
prvtStatHistDataEntry OBJECT-TYPE
|
|
SYNTAX PrvtStatHistDataEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry in prvtStatHistDataTable"
|
|
INDEX { prvtStatHistControlId, prvtStatHistDataId }
|
|
::= { prvtStatHistDataTable 1 }
|
|
|
|
PrvtStatHistDataEntry ::= SEQUENCE {
|
|
prvtStatHistDataId OCTET STRING,
|
|
prvtStatHistDataIntervalStart OCTET STRING,
|
|
prvtStatHistDataIntervalEnd OCTET STRING,
|
|
prvtStatHistDataProfile OCTET STRING,
|
|
prvtStatHistDataKey OCTET STRING,
|
|
prvtStatHistDataValue OCTET STRING,
|
|
prvtStatHistDataStatus INTEGER
|
|
}
|
|
|
|
prvtStatHistDataId OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index of prvtStatHistDataTable - 64 unsigned integer,
|
|
constantly increasing."
|
|
::= { prvtStatHistDataEntry 1 }
|
|
|
|
prvtStatHistDataIntervalStart OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Show when current interval has started."
|
|
::= { prvtStatHistDataEntry 2 }
|
|
|
|
prvtStatHistDataIntervalEnd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Show when current interval has ended"
|
|
::= { prvtStatHistDataEntry 3 }
|
|
|
|
prvtStatHistDataProfile OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Profile being used"
|
|
::= { prvtStatHistDataEntry 4 }
|
|
|
|
prvtStatHistDataKey OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Key being used"
|
|
::= { prvtStatHistDataEntry 5 }
|
|
|
|
prvtStatHistDataValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Result value, 64 unsinged int"
|
|
::= { prvtStatHistDataEntry 6 }
|
|
|
|
prvtStatHistDataStatus OBJECT-TYPE
|
|
SYNTAX INTEGER { notAvailable(1), positive(2), negative(3) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status of the operation."
|
|
::= { prvtStatHistDataEntry 7 }
|
|
|
|
END -- end of module PRVT-STATISTICS-HISTORY-MIB.
|