librenms/mibs/SENAO-ENTERPRISE-INDOOR-AP-CB-MIB
2012-05-15 15:34:09 +00:00

1041 lines
30 KiB
Plaintext

-- *****************************************************************
-- Senao Enterprise indoor AP/CB Private MIB for EAP and ECB series
--
-- Apr 2008, Adonn Fu
--
-- Copyright (c) 2000-2003 by Senao Networks, Inc.
-- All rights reserved.
-- *****************************************************************
--module definition
SENAO-ENTERPRISE-INDOOR-AP-CB-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,
Counter32, IpAddress, enterprises, TimeTicks
FROM SNMPv2-SMI
DisplayString, MacAddress, TruthValue FROM SNMPv2-TC;
-- module OID definition
senao MODULE-IDENTITY
LAST-UPDATED "0511250000Z"
ORGANIZATION "Senao R&D Dept., S/W Division"
CONTACT-INFO
"
Info
SENAO INTERNATIONAL CO., LTD.
No.500, Fusing 3 Rd., Hwa-Ya Technical Park,
Kuei-Shan Hsiang, TAOYUAN County 333, TAIWAN, R.O.C.
Tel: 886-3-328-9289
Fax: 886-3-328-9666
E-mail: info@senao.com.tw
"
DESCRIPTION
"
The MIB module defines Senao implementation-specific metrics useful in managing
IEEE 802.11 on Senao devices.
This is used as a supplement to the standard 802.11 MIB proposed by IEEE.
"
::= { enterprises 14125}
indoorWirelessDevice OBJECT IDENTIFIER ::= { senao 100 }
entSystem OBJECT IDENTIFIER ::= { indoorWirelessDevice 1 }
entLAN OBJECT IDENTIFIER ::= { indoorWirelessDevice 2 }
entWAN OBJECT IDENTIFIER ::= { indoorWirelessDevice 3 }
entMacFilter OBJECT IDENTIFIER ::= { indoorWirelessDevice 4}
entWlan OBJECT IDENTIFIER ::= { indoorWirelessDevice 5}
entSNMP OBJECT IDENTIFIER ::= { indoorWirelessDevice 6 }
entWlanCommonInfo OBJECT IDENTIFIER ::= { entWlan 1}
-- objects definition
-- entSystem OBJECT IDENTIFIER ::= { indoorWirelessDevice 1 }
-- entAdminIdleTimeOut OBJECT-TYPE
-- SYNTAX INTEGER (1..1000)
-- MAX-ACCESS read-write
-- STATUS mandatory
-- DESCRIPTION
-- "Administration idle time out in mins"
-- ::= { entSystem 1 }
entPassword OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS write-only
STATUS mandatory
DESCRIPTION
"Administration password"
::= { entSystem 2 }
entSysModel OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS mandatory
DESCRIPTION
"System model"
::= { entSystem 3 }
entSysMode OBJECT-TYPE
SYNTAX INTEGER
{
ap-router(0),
repeater(1),
ap-bridge(2),
client-bridge(3),
client-router(4),
wds-bridge(5)
}
MAX-ACCESS read-only
STATUS mandatory
DESCRIPTION
"System mode, 0:AP router, 1:Repeater, 2: AP bridge,
3: Client bridge, 4: Client router, 5: WDS bridge"
::= { entSystem 4 }
entSysUpTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS mandatory
DESCRIPTION
"System uptime"
::= { entSystem 5 }
entHwVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS mandatory
DESCRIPTION
"The version of the hardware"
::= { entSystem 6 }
entSN OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS mandatory
DESCRIPTION
"Serial Number"
::= { entSystem 7 }
entKenelVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS mandatory
DESCRIPTION
"The version of the kernel"
::= { entSystem 8 }
entAppVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS mandatory
DESCRIPTION
"The version of the system application"
::= { entSystem 9 }
entReset OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS write-only
STATUS mandatory
DESCRIPTION
"Setting this attribute TRUE causes the AP rebooted"
::= { entSystem 10 }
entResetToDefault OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS write-only
STATUS mandatory
DESCRIPTION
"Setting this attribute TRUE will Reboot the system and change settings to factory default"
::= { entSystem 11 }
entApplyModules OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS write-only
STATUS mandatory
DESCRIPTION
"Setting this attribute TRUE will apply the changed modules to reload"
::= { entSystem 12 }
-- entLAN OBJECT IDENTIFIER ::= { indoorWirelessDevice 2 }
entLANIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"LAN IP address"
::= { entLAN 1 }
entLANSubnetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"LAN subnet mask"
::= { entLAN 2 }
entSTPEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set this attribute TRUE will enable 802.1d Spanning Tree."
::= { entLAN 3 }
entDHCPEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"When system mode is not 1(Repeater) and 5(WDS bridge),
set this attribute TRUE will enable the DHCP server function of device"
::= { entLAN 4 }
entIPPoolStart OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"TWhen system mode is not 1(Repeater) and 5(WDS bridge),
set the start address of DHCP IP pool"
::= { entLAN 5 }
entIPPoolEnd OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"When system mode is not 1(Repeater) and 5(WDS bridge),
set the end address of DHCP IP pool"
::= { entLAN 6 }
entIPLeaseTime OBJECT-TYPE
SYNTAX INTEGER
{
half-hour(0),
one-hour(1),
two-hours(2),
half-day(3),
one-day(4),
two-days(5),
one-week(6),
two-weeks(7),
forever(8)
}
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"When system mode is not 1(Repeater) and 5(WDS bridge),
the time period client can have the IP address assigned by DHCP server
0(half hour),
1(one hour)
2(two hours),
3(half day),
4(one day),
5(two days),
6(one week),
7(two weeks),
8(forever)
"
::= { entLAN 7 }
-- entWAN OBJECT IDENTIFIER ::= { indoorWirelessDevice 3 }
entRouterEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"Only When op mode is 0(AP) or (Client bridge),
can set this attribute. Set TRUE will enable the router."
::= { entWAN 1 }
-- entMacFilter OBJECT IDENTIFIER ::= { indoorWirelessDevice 4 }
entLanMacFilteringEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set this attribute TRUE will enable the LAN MAC filtering"
::= { entMacFilter 1 }
entLanMacFilteringMode OBJECT-TYPE
SYNTAX INTEGER
{
white-list(0),
black-list(1)
}
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"The mode of LAN MAC filtering can be 0(white list), 1(black list)"
::= { entMacFilter 2 }
entLanMacFilterTable OBJECT-TYPE
SYNTAX SEQUENCE OF EntLanMacFilterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table provides one row for each LAN MAC filtering.
Each row contains the enterprise LAN MAC filtering table
for that LAN MAC filtering."
::= { entMacFilter 3 }
entLanMacFilterEntry OBJECT-TYPE
SYNTAX EntLanMacFilterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in the entLanMacFilterTable."
INDEX { entMacAddressIndex }
::= { entLanMacFilterTable 1 }
EntLanMacFilterEntry ::=
SEQUENCE {
entMacAddressIndex INTEGER,
entMacAddress MacAddress,
entMacFilteringValid TruthValue,
}
entMacAddressIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The auxiliary variable used to identify instances of
columnar objects in the LAN MAC Filtering Table"
::= { entLanMacFilterEntry 1 }
entMacAddress OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MAC address list in the LAN MAC filtering table"
::= { entLanMacFilterEntry 2 }
entMacFilteringValid OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The validity status of each corresponding MAC address in LAN MAC filtering table"
::= { entLanMacFilterEntry 3 }
-- entWlan OBJECT IDENTIFIER ::= { indoorWirelessDevice 5}
-- entWlanCommonInfo OBJECT IDENTIFIER ::= { entWlan 1}
entOpMode OBJECT-TYPE
SYNTAX INTEGER
{
ap(0),
client-bridge(1),
wds-bridge(2),
repeater(3)
}
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set op mode: 0(AP), 1(Client bridge), 2(WDS bridge), 3(Repeater)"
::= { entWlanCommonInfo 1 }
entRadio OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set this attribute TRUE will enable the radio"
::= { entWlanCommonInfo 2 }
entAPMode OBJECT-TYPE
SYNTAX INTEGER
{
ap(0),
wds(1)
}
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"Only when op mode is 0(AP), we can set AP mode: 0(AP), 1(WDS)"
::= { entWlanCommonInfo 3 }
entBand OBJECT-TYPE
SYNTAX INTEGER
{
ieee802dot11-b-g(0),
ieee802dot11-b(1),
ieee802dot11-a(2),
ieee802dot11-g(4),
ieee802dot11-n(6),
ieee802dot11-g-n(7),
ieee802dot11-a-n(8),
ieee802dot11-b-g-n(9)
}
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"The wireless mode: 0(802.11 b/g),
1(802.11 b),
2(802.11 a),
4(802.11 g),
6(802.11 n),
7(802.11 g/n),
8(802.11 a/n),
9(802.11 b/g/n)"
::= { entWlanCommonInfo 4 }
entESSIDNum OBJECT-TYPE
SYNTAX INTEGER (1..4)
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set the Number of multiple ESSID"
::= { entWlanCommonInfo 5 }
entChannel OBJECT-TYPE
SYNTAX INTEGER (1..14)
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"The current operating frequency channel"
::= { entWlanCommonInfo 6 }
entDataRate OBJECT-TYPE
SYNTAX INTEGER
{
auto(0),
oneMbps(1),
twoMbps(2),
fiveNhalfMbps(5),
elevenMbps(11),
sixMbps(6),
nineMbps(9),
twelveMbps(12),
eighteenMbps(18),
twentytwoMbps(24),
thirtysixMbps(36),
fortyeightMbps(48),
fiftyfourMbps(54)
}
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies the data rate at which the station may transmit data in Mbps
0(Auto), 1(1Mbps), 2(2Mbps), 5(5.5Mbps), 11(11Mbps), 6(6Mbps), 9(9Mbps), 12(12Mbps),
18(18Mbps), 24(24Mbps), 36(36Mbps), 48(48Mbps), 54(54Mbps)"
::= { entWlanCommonInfo 7 }
entNDataRate OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies the 11n data rate"
::= { entWlanCommonInfo 8 }
entTxPower OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"The transmit power level: 10(%), 25(%), 50(%), 75(%), 90(%), 100(%)"
::= { entWlanCommonInfo 9 }
entBeaconInterval OBJECT-TYPE
SYNTAX INTEGER (20..1024)
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies the number of TU that a station shall use
for scheduling Beacon transmissions"
::= { entWlanCommonInfo 10 }
entDTIMPeriod OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies the number of beacon intervals"
::= { entWlanCommonInfo 11 }
entFragmentationThreshold OBJECT-TYPE
SYNTAX INTEGER (256..2346)
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute shall specify the current maximum size, in octets,
of the MPDU that may be delivered to the PHY"
::= { entWlanCommonInfo 12 }
entRTSThreshold OBJECT-TYPE
SYNTAX INTEGER (0..2347)
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute shall indicate the number of octets in an MPDU,
below which an RTS/CTS handshake shall not be performed."
::= { entWlanCommonInfo 13 }
entChannelBandwidth OBJECT-TYPE
SYNTAX INTEGER (0..1)
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies the channel bandwidth: 0(Auto 20/40 MHZ), 1(20 MHZ)"
::= { entWlanCommonInfo 14 }
entPreambleType OBJECT-TYPE
SYNTAX INTEGER
{
short(1),
long(2)
}
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies the preamble type: 1(Short), 2(Long)"
::= { entWlanCommonInfo 15 }
entCTSProtection OBJECT-TYPE
SYNTAX INTEGER
{
auto(0),
always(1),
none(2)
}
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies the CTS protection: 0(Auto), 1(Always), 2(None)"
::= { entWlanCommonInfo 16 }
entWlanESSIDInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF EntWlanESSIDInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table provides one row for each ESSID information.
Each row contains the enterprise ESSID information Table
for that ESSID information."
::= { entWlan 2 }
entWlanESSIDInfoEntry OBJECT-TYPE
SYNTAX EntWlanESSIDInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in the entWlanESSIDInfoTable."
INDEX { entWlanESSIDInfoIndex }
::= { entWlanESSIDInfoTable 1 }
EntWlanESSIDInfoEntry ::=
SEQUENCE {
entWlanESSIDInfoIndex INTEGER,
entESSID OCTET STRING,
entBroadcastESSID TruthValue,
entWMM TruthValue,
entEncryption INTEGER,
entWlanAuthenticationType INTEGER
}
entWlanESSIDInfoIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The auxiliary variable used to identify instances of columnar
objects in the ESSID information Table"
::= { entWlanESSIDInfoEntry 1 }
entESSID OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute reflects the Service Set ID used in
the Desired- SSID parameter of the most recent MLME_Scan.request"
::= { entWlanESSIDInfoEntry 2 }
entBroadcastESSID OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set this attribute TRUE will enable the hidden SSID"
::= { entWlanESSIDInfoEntry 3 }
entWMM OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set this attribute TRUE will enable WMM"
::= { entWlanESSIDInfoEntry 4 }
entEncryption OBJECT-TYPE
SYNTAX INTEGER (0..4)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The WLAN encryption: 0(none), 1(WEP), 2(TKIP), 3(AES), 4(TKIPAES)"
::= { entWlanESSIDInfoEntry 5 }
entWlanAuthenticationType OBJECT-TYPE
SYNTAX INTEGER (0..8)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The current authentication algorithms: 0 (openSystem), 1(wepAuto),
2(sharedKey), 3(WPAPSK), 4(WPA), 5(WPA2PSK), 6(WPA2), 7(WPA1WPA2),
8(WPA1PSKWPA2PSK)"
::= { entWlanESSIDInfoEntry 6 }
entWlanWepInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF EntWlanWepInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table provides one row for each WEP information.
Each row contains the enterprise WEP information Table
for that WEP information."
::= { entWlan 3 }
entWlanWepInfoEntry OBJECT-TYPE
SYNTAX EntWlanWepInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in the entWlanWepInfoTable."
INDEX { entWlanESSIDIndex }
::= { entWlanWepInfoTable 1 }
EntWlanWepInfoEntry ::=
SEQUENCE {
entWlanESSIDIndex INTEGER,
entWlanWepKeyID INTEGER,
entWlanWepKey1Value OCTET STRING,
entWlanWepKey2Value OCTET STRING,
entWlanWepKey3Value OCTET STRING,
entWlanWepKey4Value OCTET STRING
}
entWlanESSIDIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The auxiliary variable used to identify instances of columnar
objects in the WEP information Table"
::= { entWlanWepInfoEntry 1 }
entWlanWepKeyID OBJECT-TYPE
SYNTAX INTEGER (1..4)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute shall indicate the use of the first, second, third, or fourth
element of the WEPDefaultKeys array"
::= { entWlanWepInfoEntry 2 }
entWlanWepKey1Value OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set key1 string. (5 or 13 ASCCI characters, 10 or 26 hex numbers)"
::= { entWlanWepInfoEntry 3 }
entWlanWepKey2Value OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set key2 string. (5 or 13 ASCCI characters, 10 or 26 hex numbers)"
::= { entWlanWepInfoEntry 4 }
entWlanWepKey3Value OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set key3 string. (5 or 13 ASCCI characters, 10 or 26 hex numbers)"
::= { entWlanWepInfoEntry 5 }
entWlanWepKey4Value OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set key4 string. (5 or 13 ASCCI characters, 10 or 26 hex numbers)"
::= { entWlanWepInfoEntry 6 }
entWlanWPAInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF EntWlanWPAInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table provides one row for each WPA information.
Each row contains the enterprise WPA information Table
for that WPA information."
::= { entWlan 4 }
entWlanWPAInfoEntry OBJECT-TYPE
SYNTAX EntWlanWPAInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in the entWlanWPAInfoTable."
INDEX { entWlanWPAESSIDIndex }
::= { entWlanWPAInfoTable 1 }
EntWlanWPAInfoEntry ::=
SEQUENCE {
entWlanWPAESSIDIndex INTEGER,
entPresharedKey DisplayString
}
entWlanWPAESSIDIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The auxiliary variable used to identify instances of columnar
objects in the WPA information Table"
::= { entWlanWPAInfoEntry 1 }
entPresharedKey OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS write-only
STATUS current
DESCRIPTION
"The WPA Pre-Shared key. (8~63 ASCII or 64 HEX)"
::= { entWlanWPAInfoEntry 2 }
ent802dot1xInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF Ent802dot1xInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table provides one row for each 802.1x information.
Each row contains the enterprise 802.1x information Table
for that 802.1x information."
::= { entWlan 5 }
ent802dot1xInfoEntry OBJECT-TYPE
SYNTAX Ent802dot1xInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in the ent802dot1xInfoTable."
INDEX { entWlan802dot1xESSIDIndex }
::= { ent802dot1xInfoTable 1 }
Ent802dot1xInfoEntry ::=
SEQUENCE {
entWlan802dot1xESSIDIndex INTEGER,
entRADIUSServerIPAddress IpAddress,
entRADIUSServerPort INTEGER,
entRADIUSServerPassword DisplayString,
entWlan802dot1xEnable TruthValue
}
entWlan802dot1xESSIDIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The auxiliary variable used to identify instances of columnar
objects in the 802.1x information Table"
::= { ent802dot1xInfoEntry 1 }
entRADIUSServerIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The address of RADIUS Server"
::= { ent802dot1xInfoEntry 2 }
entRADIUSServerPort OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The port of RADIUS Server"
::= { ent802dot1xInfoEntry 3 }
entRADIUSServerPassword OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS write-only
STATUS current
DESCRIPTION
"The password of RADIUS Server"
::= { ent802dot1xInfoEntry 4 }
entWlan802dot1xEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set this attribute TRUE will enable 802.1x"
::= { ent802dot1xInfoEntry 5 }
-- Wlan ClientList table
entWlanClientListInfoTable OBJECT-TYPE
SYNTAX SEQUENCE OF EntWlanClientListInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table provides one row for Wlan client list information."
::= { entWlan 6 }
entWlanClientListInfoEntry OBJECT-TYPE
SYNTAX EntWlanClientListInfoEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in the entWlanClientListInfoTable."
INDEX { entCLInfoIndex }
::= { entWlanClientListInfoTable 1 }
EntWlanClientListInfoEntry ::=
SEQUENCE {
entCLInfoIndex INTEGER,
entCLInterface OCTET STRING,
entCLMAC OCTET STRING,
entCLRx OCTET STRING,
entCLTx OCTET STRING,
entCLSignal INTEGER,
entCLConnectedTime OCTET STRING,
entCLIdleTime OCTET STRING
}
entCLInfoIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The auxiliary variable used to identify instances of columnar
objects in the ClientList information Table"
::= { entWlanClientListInfoEntry 1 }
entCLInterface OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Client connected SSID"
::= { entWlanClientListInfoEntry 2 }
entCLMAC OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Client MAC"
::= { entWlanClientListInfoEntry 3 }
entCLRx OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Rx value"
::= { entWlanClientListInfoEntry 4 }
entCLTx OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Tx value"
::= { entWlanClientListInfoEntry 5 }
entCLSignal OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Client Wlan Signal"
::= { entWlanClientListInfoEntry 6 }
entCLConnectedTime OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Client connected time"
::= { entWlanClientListInfoEntry 7 }
entCLIdleTime OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Client idle time"
::= { entWlanClientListInfoEntry 8 }
-- entSNMP OBJECT IDENTIFIER ::= { indoorWirelessDevice 6 }
entSNMPStatus OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"The status of current SNMP agent.0:disable, 1:Enable"
::= { entSNMP 1 }
entSNMPVerType OBJECT-TYPE
SYNTAX INTEGER
{
all(0),
v1(1),
v2c(2),
v3(3)
}
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"The version of current SNMP agent.0:all, 1: v1, 2:v2c, 3:v3"
::= { entSNMP 2 }
entSNMPCommunityTable OBJECT-TYPE
SYNTAX SEQUENCE OF EntSNMPCommunityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table provides one row for each SNMP community.
Each row contains the enterprise SNMP community table
for that SNMP community."
::= { entSNMP 3 }
entSNMPCommunityEntry OBJECT-TYPE
SYNTAX EntSNMPCommunityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in the entSNMPCommunityTable."
INDEX { entSNMPCommunityIndex }
::= { entSNMPCommunityTable 1 }
EntSNMPCommunityEntry ::=
SEQUENCE {
entSNMPCommunityIndex INTEGER,
entSNMPCommunityName DisplayString,
entSNMPCommunityType INTEGER,
entSNMPCommunityValid TruthValue,
}
entSNMPCommunityIndex OBJECT-TYPE
SYNTAX INTEGER (1..2)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The auxiliary variable used to identify instances of
columnar objects in the SNMP Community Table"
::= { entSNMPCommunityEntry 1 }
entSNMPCommunityName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The community name used to access SNMP device."
::= { entSNMPCommunityEntry 2 }
entSNMPCommunityType OBJECT-TYPE
SYNTAX INTEGER
{
read(1),
write(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The auxiliary variable used to identify instances of
columnar objects in the SNMP Community Table"
::= { entSNMPCommunityEntry 3 }
entSNMPCommunityValid OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Display the validity information of corresponding community index"
::= { entSNMPCommunityEntry 4 }
entSNMPTrap OBJECT IDENTIFIER ::= { entSNMP 4 }
entTrapStatus OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"The trap status of current SNMP agent.0:disable, 1:Enable"
::= { entSNMPTrap 1 }
entTrapVer OBJECT-TYPE
SYNTAX INTEGER
{
all(0),
v1(1),
v2c(2),
v3(3)
}
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"The trap version of current SNMP agent.0:all, 1: v1, 2:v2c, 3:v3"
::= { entSNMPTrap 2 }
entTrapReceiverIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specify the IP address(host) to receive the trap report"
::= { entSNMPTrap 3 }
entTrapReceiverCommunityName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specify the community name for SNMP manager to receive the trap report"
::= { entSNMPTrap 4 }
entTraps OBJECT IDENTIFIER ::= { indoorWirelessDevice 20 }
entSystemTraps OBJECT IDENTIFIER ::= { entTraps 1 }
entWanTraps OBJECT IDENTIFIER ::= { entTraps 2 }
entSystemTrapsReboot NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"The trap is generated when the system is rebooted."
::= {entSystemTraps 1}
entSystemTrapsRestoreToDefault NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"The trap is generated when the default configuration of the system
is restored."
::= {entSystemTraps 2}
entSystemTrapsReloadModules NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"The trap is generated when the system modules are reloaded."
::= {entSystemTraps 3}
entWanTrapsLinkDisconnect NOTIFICATION-TYPE
OBJECTS {ifIndex}
STATUS current
DESCRIPTION
"The trap is generated when the PHY of WAN is disconnected and
it was connected."
::= {entWanTraps 1}
entWanTrapsLinkRecover NOTIFICATION-TYPE
OBJECTS {ifIndex}
STATUS current
DESCRIPTION
"The trap is generated when the PHY of WAN is connected and
it was disconnected"
::= {entWanTraps 2}
END