CISCOSB-STACK-MIB DEFINITIONS ::= BEGIN
-- Title: CISCOSB LOCALIZATION ROS
-- This Private MIB supports the unit id configuration for stack of ROS products
-- Version: 7.40
-- Date: 21 Nov 2005
--
-- 01-Nov-2005 Add rlStackUnitMacAddressAfterReset
-- 21-Nov-2005 Change range of rlStackActiveUnitIdAfterReset
IMPORTS
MacAddress FROM BRIDGE-MIB
switch001 FROM CISCOSB-MIB OBJECT-TYPE,
MODULE-IDENTITY FROM SNMPv2-SMI
TruthValue, TEXTUAL-CONVENTION FROM SNMPv2-TC;
rlStack MODULE-IDENTITY
LAST-UPDATED "200504140000Z"
ORGANIZATION "Cisco Small Business"
CONTACT-INFO
"Postal: 170 West Tasman Drive
San Jose , CA 95134-1706
USA
Website: Cisco Small Business Home http://www.cisco.com/smb>;,
Cisco Small Business Support Community <http://www.cisco.com/go/smallbizsupport>"
DESCRIPTION
"The private MIB module definition for stack."
REVISION "200504140000Z"
DESCRIPTION
"Initial revision."
::= { switch001 107 }
rlStackActiveUnitIdTable OBJECT-TYPE
SYNTAX SEQUENCE OF RlStackActiveUnitIdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" The table listing the active unit id of the requested unit."
::= {rlStack 1 }
rlStackActiveUnitIdEntry OBJECT-TYPE
SYNTAX RlStackActiveUnitIdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" An entry in the rlStackActiveUnitIdTable."
INDEX {rlStackCurrentUnitId }
::= {rlStackActiveUnitIdTable 1 }
RlStackActiveUnitIdEntry ::= SEQUENCE {
rlStackCurrentUnitId INTEGER,
rlStackActiveUnitIdAfterReset INTEGER
}
rlStackCurrentUnitId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The unit number device, which is the active unit id"
::= {rlStackActiveUnitIdEntry 1 }
rlStackActiveUnitIdAfterReset OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the unit id that will be after reset."
::= {rlStackActiveUnitIdEntry 2 }
rlStackUnitModeAfterReset OBJECT-TYPE
SYNTAX INTEGER {
standalone(1),
stack(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"set unit type that will be after reset, standalone or stack."
::= {rlStack 2 }
rlStackUnitMode OBJECT-TYPE
SYNTAX INTEGER {
standalone(1),
stack(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"show unit type standalone or stack."
::= {rlStack 3 }
rlStackUnitMacAddressAfterReset OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The MAC address used by this bridge after rest."
REFERENCE
"IEEE 802.1D-1990: Sections 6.4.1.1.3 and 3.12.5"
::= { rlStack 4 }
END