-- Dell Remote Access Controller (RAC) and Chassis Management Controller (CMC)
-- Management Information Base
--
-- This MIB is the legacy iDRAC MIB. Changes are no longer made to this MIB
-- for iDRACs. iDRACs don't support all of the objects and traps defined
-- in this MIB. There is a new and more extensive iDRAC MIB available for
-- newer iDRACs (iDRAC7 and newer).
--
-- This MIB is also the CMC MIB. Changes are made to this MIB only for CMCs now.
--
-- Copyright (c) 2014 Dell Inc.
--
-- Last Changed Revision: 16
-- Last Changed Date: 2014-07-14 12:25:06 -0500 (Mon, 14 Jul 2014)
-- Text Last Updated: 2014-07-14 12:25:06 -0500 (Mon, 14 Jul 2014)
--
DELL-RAC-MIB DEFINITIONS ::= BEGIN
IMPORTS
enterprises, TimeTicks
FROM RFC1155-SMI
OBJECT-TYPE
FROM RFC-1212
TRAP-TYPE
FROM RFC-1215
DisplayString
FROM RFC1213-MIB;
-- text convention ------------------------------------------------------------------------
-------------------------------------------------------------------------------
-- This data type is used to model textual information taken
-- from the NVT ASCII character set. By convention, objects
-- with this syntax are declared as having
-- SIZE (0..1023)
-------------------------------------------------------------------------------
DellString ::= DisplayString (SIZE (0..1023))
DellRacType ::= INTEGER
{
other(1), -- the DRAC type is not one of the following
unknown(2), -- the DRAC type is unknown
dracIII(3), -- Drac III
era(4), -- ERA
drac4(5), -- Drac 4
drac5(6), -- Drac 5
drac5MC(7), -- Drac 5/MC
cmc(8), -- CMC
idrac(9), -- iDRAC
idrac7monolithic(16), -- iDRAC7 Monolithic
idrac7modular(17), -- iDRAC7 Modular
vrtxCMC(18), -- VRTX CMC
fx2CMC(19), -- FX2 Family CMC
idrac8monolithic(32), -- iDRAC8 Monolithic
idrac8modular(33) -- iDRAC8 Modular
}
DellStatus ::= INTEGER
{
other(1), -- the status of the object is not one of the following:
unknown(2), -- the status of the object is unknown
-- (not known or monitored)
ok(3), -- the status of the object is ok
nonCritical(4), -- the status of the object is warning, non-critical
critical(5), -- the status of the object is critical (failure)
nonRecoverable(6) -- the status of the object is non-recoverable (dead)
}
-------------------------------------------------------------------------------
-- DellPowerReading is a string representation of a floating point value,
-- having exactly 3 digits of precision, and a maximum of 31 characters.
--
-- DellChassisPowerIndexRange defines the possible chassis power instances
-- in this MIB.
--
-- DellCMCPSUIndexRange defines the possible CMC Power Supply Unit (PSU)
-- instances, per chassis power instance, in this MIB.
--
-- DellCMCPSUCapable is an enumeration of PSU presence and/or monitoring
-- capabilities.
--
-- DellTemperatureReading is an integer value, expressed in degrees Celsius.
-------------------------------------------------------------------------------
DellPowerReading ::= DisplayString (SIZE (0..32))
DellCMCPowerIndexRange ::= INTEGER (1..1)
DellCMCPSUIndexRange ::= INTEGER (1..6)
DellCMCPSUCapable ::= INTEGER
{
absent(1), -- power supply is not present
none(2), -- no power monitoring abilities
basic(3) -- basic power monitoring abilities
}
DellTemperatureReading ::= INTEGER
-------------------------------------------------------------------------------
-- DellTimestamp is defined in the displayable format:
--
-- yyyymmddHHMMSS.uuuuuuDooo
--
-- where yyyy is the year, mm is the month number, dd is the day of the month,
-- HHMMSS are the hours, minutes and seconds, respectively, uuuuuu is the
-- number of microseconds, D is the UTC offset direction, and ooo is the
-- offset from UTC, in minutes.
--
-- Note: D is a plus (+) sign if east of UTC, and a minus (-) if west of UTC.
--
-- For example, Wednesday, May 25, 1994, at 1:30:15 PM EDT
-- would be represented as: 19940525133015.000000-300
-------------------------------------------------------------------------------
DellTimestamp ::= DisplayString (SIZE (26))
-------------------------------------------------------------------------------
-- DellCMCServerIndexRange defines the possible chassis server instances
-- in this MIB.
--
-- DellCMCServerCapable is an enumeration of server presence and/or monitoring
-- capabilities.
-------------------------------------------------------------------------------
DellCMCServerIndexRange ::= INTEGER (1..32)
DellCMCServerCapable ::= INTEGER
{
absent(1), -- server is not present
none(2), -- no server monitoring abilities
basic(3), -- basic server monitoring abilities
off(4) -- server is powered off
}
-- MIB Objects and Tables --------------------------------------------------------
dell OBJECT IDENTIFIER ::= { enterprises 674 }
server3 OBJECT IDENTIFIER ::= { dell 10892 }
drsOutofBandGroup OBJECT IDENTIFIER ::= { server3 2 }
drsInformationGroup OBJECT IDENTIFIER ::= { drsOutofBandGroup 1 }
drsProductInfoGroup OBJECT IDENTIFIER ::= { drsInformationGroup 1 }
drsFirmwareGroup OBJECT IDENTIFIER ::= { drsInformationGroup 2 }
drsStatusGroup OBJECT IDENTIFIER ::= { drsOutofBandGroup 2 }
drsChassisStatusGroup OBJECT IDENTIFIER ::= { drsOutofBandGroup 3 }
drsStatusNowGroup OBJECT IDENTIFIER ::= { drsChassisStatusGroup 1 }
drsStatusPrevGroup OBJECT IDENTIFIER ::= { drsChassisStatusGroup 2 }
drsStatusChangeGroup OBJECT IDENTIFIER ::= { drsChassisStatusGroup 3 }
drsChassisPowerGroup OBJECT IDENTIFIER ::= { drsOutofBandGroup 4 }
DrsCMCPowerTableEntry ::= SEQUENCE
{
drsChassisIndex DellCMCPowerIndexRange,
drsPotentialPower DellPowerReading,
drsIdlePower DellPowerReading,
drsMaxPowerSpecification DellPowerReading,
drsPowerSurplus DellPowerReading,
drsKWhCumulative DellPowerReading,
drsKWhCumulativeTime DellTimestamp,
drsWattsPeakUsage DellPowerReading,
drsWattsPeakTime DellTimestamp,
drsWattsMinUsage DellPowerReading,
drsWattsMinTime DellTimestamp,
drsWattsResetTime DellTimestamp,
drsWattsReading DellPowerReading,
drsAmpsReading DellPowerReading
}
DrsCMCPSUTableEntry ::= SEQUENCE
{
drsPSUChassisIndex DellCMCPowerIndexRange,
drsPSUIndex DellCMCPSUIndexRange,
drsPSULocation DellString,
drsPSUMonitoringCapable DellCMCPSUCapable,
drsPSUVoltsReading DellPowerReading,
drsPSUAmpsReading DellPowerReading,
drsPSUWattsReading DellPowerReading
}
drsChassisServerGroup OBJECT IDENTIFIER ::= { drsOutofBandGroup 5 }
DrsCMCServerTableEntry ::= SEQUENCE
{
drsServerIndex DellCMCServerIndexRange,
drsServerMonitoringCapable DellCMCServerCapable,
drsServerServiceTag DellString,
drsServerSlotName DellString,
drsServerSlotNumber DellString,
drsServerNodeID DellString
}
drsCMCAlertGroup OBJECT IDENTIFIER ::= { drsOutofBandGroup 20 }
drsChassisAlertVariables OBJECT IDENTIFIER ::= { drsCMCAlertGroup 10 }
drsCMCAlert2Group OBJECT IDENTIFIER ::= { drsOutofBandGroup 21 }
drsChassisAlert2Variables OBJECT IDENTIFIER ::= { drsCMCAlert2Group 10 }
drsAlertGroup OBJECT IDENTIFIER ::= { drsOutofBandGroup 5000 }
drsAlertVariables OBJECT IDENTIFIER ::= { drsAlertGroup 10 }
-- Variables and Traps ------------------------------------------------------------------------
-------------------------------------------------------------------------------
-- group: product information
-------------------------------------------------------------------------------
drsProductName OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0001.0001 This attribute defines the product name of a chassis management controller."
::= { drsProductInfoGroup 1 }
drsProductShortName OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0001.0002 This attribute defines the short product name of a chassis management controller. "
::= { drsProductInfoGroup 2 }
drsProductDescription OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0001.0003 This attribute defines the product description of a chassis management controller. "
::= { drsProductInfoGroup 3 }
drsProductManufacturer OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0001.0004 This attribute defines the product manufacturer of a chassis management controller. "
::= { drsProductInfoGroup 4 }
drsProductVersion OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0001.0005 This attribute defines the product version of a chassis management controller. "
::= { drsProductInfoGroup 5 }
drsChassisServiceTag OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0001.0007 This attribute defines the Service Tag of the chassis. "
::= { drsProductInfoGroup 6 }
drsProductURL OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0001.0006 This attribute defines the out-of-band UI URL of a chassis management controller. "
::= { drsProductInfoGroup 7 }
drsProductChassisAssetTag OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0001.0008 This attribute defines the Asset Tag of the chassis. "
::= { drsProductInfoGroup 8 }
drsProductChassisLocation OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0001.0009 This attribute defines the location of the chassis. "
::= { drsProductInfoGroup 9 }
drsProductChassisName OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0001.0010 This attribute defines the name of the chassis. "
::= { drsProductInfoGroup 10 }
drsSystemServiceTag OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0001.0011 This attribute defines the service tag of a system. "
::= { drsProductInfoGroup 11 }
drsProductSystemAssetTag OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0001.0012 This attribute defines the asset tag of a system. "
::= { drsProductInfoGroup 12 }
drsProductSystemSlot OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0001.0013 This attribute defines the slot number of a CMC. "
::= { drsProductInfoGroup 13 }
drsProductType OBJECT-TYPE
SYNTAX DellRacType
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0001.0014 This attribute defines type of a remote access card "
::= { drsProductInfoGroup 14 }
drsProductChassisDataCenter OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0001.0015 This attribute defines the Data Center locator of the chassis. "
::= { drsProductInfoGroup 15 }
drsProductChassisAisle OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0001.0016 This attribute defines the Aisle locator of the chassis. "
::= { drsProductInfoGroup 16 }
drsProductChassisRack OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0001.0017 This attribute defines the Rack locator of the chassis. "
::= { drsProductInfoGroup 17 }
drsProductChassisRackSlot OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0001.0018 This attribute defines the Rack Slot locator of the chassis. "
::= { drsProductInfoGroup 18 }
drsProductChassisModel OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0001.0019 This attribute defines the Model of the chassis."
::= { drsProductInfoGroup 19 }
drsProductChassisExpressServiceCode OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0001.0020 This attribute defines the Express Service Code of the chassis."
::= { drsProductInfoGroup 20 }
drsProductChassisSystemID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0001.0021 This attribute defines the System ID of the chassis."
::= { drsProductInfoGroup 21 }
drsProductChassisSize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0001.0022 This attribute defines the size of the
chassis in rack units (U). A U is a standard unit of
measure for the height of a rack or rack-mountable component."
::= { drsProductInfoGroup 22 }
-------------------------------------------------------------------------------
-- group: firmware
-------------------------------------------------------------------------------
drsFirmwareVersion OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0002.0001 This attribute defines the firmware version of chassis management controller 1."
::= { drsFirmwareGroup 1 }
drsiKVMFirmwareVersion OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0002.0002 This attribute defines the firmware version of the iKVM. "
::= { drsFirmwareGroup 2 }
drsFirmwareVersion2 OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0002.0003 This attribute defines the firmware version of chassis management controller 2."
::= { drsFirmwareGroup 3 }
-------------------------------------------------------------------------------
-- group: chassis status
-------------------------------------------------------------------------------
drsGlobalSystemStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0002.0001.0001 This attribute defines the overall chassis status
being monitored by the chassis management card."
::= { drsStatusGroup 1 }
drsGlobalCurrStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0001.0001 This attribute defines the overall chassis status
being monitored by the chassis management card."
::= { drsStatusNowGroup 1 }
drsIOMCurrStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0001.0002 This attribute defines the IOM subsystem status
being monitored by the chassis management card."
::= { drsStatusNowGroup 2 }
drsKVMCurrStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0001.0003 This attribute defines the iKVM subsystem health status
being monitored by the chassis management card."
::= { drsStatusNowGroup 3 }
drsRedCurrStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0001.0004 This attribute defines the Redundancy status
being monitored by the chassis management card."
::= { drsStatusNowGroup 4 }
drsPowerCurrStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0001.0005 This attribute defines the power subsystem health status
being monitored by the chassis management card."
::= { drsStatusNowGroup 5 }
drsFanCurrStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0001.0006 This attribute defines the Fan subsystem health status
being monitored by the chassis management card."
::= { drsStatusNowGroup 6 }
drsBladeCurrStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0001.0007 This attribute defines the Blade subsystem health status
being monitored by the chassis management card."
::= { drsStatusNowGroup 7 }
drsTempCurrStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0001.0008 This attribute defines the Temp Sensor subsystem health status
being monitored by the chassis management card."
::= { drsStatusNowGroup 8 }
drsCMCCurrStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0001.0009 This attribute defines the CMC health status
being monitored by the chassis management card."
::= { drsStatusNowGroup 9 }
drsChassisFrontPanelAmbientTemperature OBJECT-TYPE
SYNTAX DellTemperatureReading
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0001.0010 This attribute defines the ambient temperature
reading (in degrees Celsius) for the chassis front panel controller."
::= { drsStatusNowGroup 10 }
drsCMCAmbientTemperature OBJECT-TYPE
SYNTAX DellTemperatureReading
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0001.0011 This attribute defines the ambient temperature
reading (in degrees Celsius) for the chassis management card."
::= { drsStatusNowGroup 11 }
drsCMCProcessorTemperature OBJECT-TYPE
SYNTAX DellTemperatureReading
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0001.0012 This attribute defines the temperature reading
(in degrees Celsius) for the chassis management card processor."
::= { drsStatusNowGroup 12 }
drsGlobalPrevStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0002.0001 This attribute defines the previous chassis status
recorded by the chassis management card."
::= { drsStatusPrevGroup 1 }
drsIOMPrevStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0002.0002 This attribute defines the previous IOM subsystem status
recorded by the chassis management card."
::= { drsStatusPrevGroup 2 }
drsKVMPrevStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0002.0003 This attribute defines the previous iKVM subsystem health status
recorded by the chassis management card."
::= { drsStatusPrevGroup 3 }
drsRedPrevStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0002.0004 This attribute defines the previous Redundancy status
recorded by the chassis management card."
::= { drsStatusPrevGroup 4 }
drsPowerPrevStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0002.0005 This attribute defines the previous power subsystem health status
recorded by the chassis management card."
::= { drsStatusPrevGroup 5 }
drsFanPrevStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0002.0006 This attribute defines the previous Fan health status
being monitored by the chassis management card."
::= { drsStatusPrevGroup 6 }
drsBladePrevStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0002.0007 This attribute defines the previous Blade subsystem health status
recorded by the chassis management card."
::= { drsStatusPrevGroup 7 }
drsTempPrevStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0001.0008 This attribute defines the Temp Sensor health status
being monitored by the chassis management card."
::= { drsStatusPrevGroup 8 }
drsCMCPrevStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0001.0009 This attribute defines the CMC health status
being monitored by the chassis management card."
::= { drsStatusPrevGroup 9 }
drsGlobalChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0003.0001 This attribute defines the timestamp of the most recent
global status change."
::= { drsStatusChangeGroup 1 }
drsIOMChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0003.0002 This attribute defines the timestamp of the most recent
IOM status change."
::= { drsStatusChangeGroup 2 }
drsKVMChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0003.0003 This attribute defines the timestamp of the most recent
iKVM status change."
::= { drsStatusChangeGroup 3 }
drsRedChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0003.0004 This attribute defines the timestamp of the most recent
Redundancy status change."
::= { drsStatusChangeGroup 4 }
drsPowerChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0003.0005 This attribute defines the timestamp of the most recent
power health status change."
::= { drsStatusChangeGroup 5 }
drsFanChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0003.0006 This attribute defines the timestamp of the most recent
Fan health status change."
::= { drsStatusChangeGroup 6 }
drsBladeChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0003.0007 This attribute defines the timestamp of the most recent
Blade health status change."
::= { drsStatusChangeGroup 7 }
drsTempChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0003.0008 This attribute defines the timestamp of the most recent
Temp Sensor health status change."
::= { drsStatusChangeGroup 8 }
drsCMCChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0003.0009 This attribute defines the timestamp of the most recent
CMC health status change."
::= { drsStatusChangeGroup 9 }
-------------------------------------------------------------------------------
-- group: chassis power
-------------------------------------------------------------------------------
drsCMCPowerTable OBJECT-TYPE
SYNTAX SEQUENCE OF DrsCMCPowerTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "0004.0001 This object defines the CMC power table."
::= { drsChassisPowerGroup 1 }
drsCMCPowerTableEntry OBJECT-TYPE
SYNTAX DrsCMCPowerTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "0004.0001.0001 This object defines the CMC power table entry."
INDEX { drsChassisIndex }
::= { drsCMCPowerTable 1 }
drsCMCPSUTable OBJECT-TYPE
SYNTAX SEQUENCE OF DrsCMCPSUTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "0004.0002 This object defines the CMC PSU table."
::= { drsChassisPowerGroup 2 }
drsCMCPSUTableEntry OBJECT-TYPE
SYNTAX DrsCMCPSUTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "0004.0002.0001 This object defines the CMC PSU table entry."
INDEX { drsPSUChassisIndex, drsPSUIndex }
::= { drsCMCPSUTable 1 }
-------------------------------------------------------------------------------
-- table: CMC power information
-------------------------------------------------------------------------------
drsChassisIndex OBJECT-TYPE
SYNTAX DellCMCPowerIndexRange
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0001.0001.0001 This attribute defines the index
(one-based) of the associated chassis."
::= { drsCMCPowerTableEntry 1 }
drsPotentialPower OBJECT-TYPE
SYNTAX DellPowerReading
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0001.0001.0002 This attribute defines the power (in Watts) required by
the chassis infrastructure, plus the sum of the maximum power requirements
for all currently powered-on servers."
::= { drsCMCPowerTableEntry 2 }
drsIdlePower OBJECT-TYPE
SYNTAX DellPowerReading
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0001.0001.0003 This attribute defines the power (in Watts) required by
the chassis infrastructure, plus the sum of the minimum power requirements
for all currently powered-on servers."
::= { drsCMCPowerTableEntry 3 }
drsMaxPowerSpecification OBJECT-TYPE
SYNTAX DellPowerReading
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0001.0001.0004 This attribute defines the power limit (in Watts)
at which server throttling will take place."
::= { drsCMCPowerTableEntry 4 }
drsPowerSurplus OBJECT-TYPE
SYNTAX DellPowerReading
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0001.0001.0005 This attribute defines the power surplus (in Watts)
remaining above the drsPotentialPower reading."
::= { drsCMCPowerTableEntry 5 }
drsKWhCumulative OBJECT-TYPE
SYNTAX DellPowerReading
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0001.0001.0006 This attribute defines the cumulative chassis power
usage (in KWh) since last reset."
::= { drsCMCPowerTableEntry 6 }
drsKWhCumulativeTime OBJECT-TYPE
SYNTAX DellTimestamp
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0001.0001.0007 This attribute defines the timestamp of the most recent
chassis power accumulator reset."
::= { drsCMCPowerTableEntry 7 }
drsWattsPeakUsage OBJECT-TYPE
SYNTAX DellPowerReading
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0001.0001.0008 This attribute defines the chassis peak power
usage (in Watts) since last reset."
::= { drsCMCPowerTableEntry 8 }
drsWattsPeakTime OBJECT-TYPE
SYNTAX DellTimestamp
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0001.0001.0009 This attribute defines the timestamp of the most recent
chassis peak power usage."
::= { drsCMCPowerTableEntry 9 }
drsWattsMinUsage OBJECT-TYPE
SYNTAX DellPowerReading
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0001.0001.0010 This attribute defines the chassis mimimum power
usage (in Watts) since last reset."
::= { drsCMCPowerTableEntry 10 }
drsWattsMinTime OBJECT-TYPE
SYNTAX DellTimestamp
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0001.0001.0011 This attribute defines the timestamp of the most recent
chassis minimum power usage."
::= { drsCMCPowerTableEntry 11 }
drsWattsResetTime OBJECT-TYPE
SYNTAX DellTimestamp
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0001.0001.0012 This attribute defines the timestamp of the most recent
reset of the chassis min/peak Watts readings."
::= { drsCMCPowerTableEntry 12 }
drsWattsReading OBJECT-TYPE
SYNTAX DellPowerReading
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0001.0001.0013 This attribute defines the instantaneous chassis power
usage (in Watts)."
::= { drsCMCPowerTableEntry 13 }
drsAmpsReading OBJECT-TYPE
SYNTAX DellPowerReading
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0001.0001.0014 This attribute defines the instantaneous chassis current
usage (in Watts)."
::= { drsCMCPowerTableEntry 14 }
-------------------------------------------------------------------------------
-- table: CMC PSU info
-------------------------------------------------------------------------------
drsPSUChassisIndex OBJECT-TYPE
SYNTAX DellCMCPowerIndexRange
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0002.0001.0001 This attribute defines the index
(one-based) of the associated chassis."
::= { drsCMCPSUTableEntry 1 }
drsPSUIndex OBJECT-TYPE
SYNTAX DellCMCPSUIndexRange
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0002.0001.0002 This attribute defines the index
(one-based) of the associated CMC PSU."
::= { drsCMCPSUTableEntry 2 }
drsPSULocation OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0002.0001.0003 This attribute defines the location
of the CMC PSU."
::= { drsCMCPSUTableEntry 3 }
drsPSUMonitoringCapable OBJECT-TYPE
SYNTAX DellCMCPSUCapable
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0002.0001.0004 This attribute defines the PSU Monitoring
capabilities, or the absence of a PSU in this location."
::= { drsCMCPSUTableEntry 4 }
drsPSUVoltsReading OBJECT-TYPE
SYNTAX DellPowerReading
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0002.0001.0005 This attribute defines the instantaneous
PSU Voltage reading."
::= { drsCMCPSUTableEntry 5 }
drsPSUAmpsReading OBJECT-TYPE
SYNTAX DellPowerReading
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0002.0001.0006 This attribute defines the instantaneous
PSU Current reading."
::= { drsCMCPSUTableEntry 6 }
drsPSUWattsReading OBJECT-TYPE
SYNTAX DellPowerReading
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0002.0001.0007 This attribute defines the instantaneous
PSU Wattage reading."
::= { drsCMCPSUTableEntry 7 }
-------------------------------------------------------------------------------
-- group: chassis servers
-------------------------------------------------------------------------------
drsCMCServerTable OBJECT-TYPE
SYNTAX SEQUENCE OF DrsCMCServerTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "0005.0001 This object defines the CMC server table."
::= { drsChassisServerGroup 1 }
drsCMCServerTableEntry OBJECT-TYPE
SYNTAX DrsCMCServerTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "0005.0001.0001 This object defines the CMC server table entry."
INDEX { drsServerIndex }
::= { drsCMCServerTable 1 }
-------------------------------------------------------------------------------
-- table: CMC Server info
-------------------------------------------------------------------------------
drsServerIndex OBJECT-TYPE
SYNTAX DellCMCServerIndexRange
ACCESS read-only
STATUS mandatory
DESCRIPTION "0005.0001.0001.0001 This attribute defines the index
(one-based) of the associated CMC server."
::= { drsCMCServerTableEntry 1 }
drsServerMonitoringCapable OBJECT-TYPE
SYNTAX DellCMCServerCapable
ACCESS read-only
STATUS mandatory
DESCRIPTION "0005.0001.0001.0002 This attribute defines the server monitoring
capabilities, or the absence of a server in this location."
::= { drsCMCServerTableEntry 2 }
drsServerServiceTag OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0005.0001.0001.0003 This attribute defines the Service Tag
of the CMC server."
::= { drsCMCServerTableEntry 3 }
drsServerSlotName OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0005.0001.0001.0004 This attribute defines the Slot Name
of the CMC server."
::= { drsCMCServerTableEntry 4 }
drsServerSlotNumber OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0005.0001.0001.0005 This attribute defines the Chassis
Slot Number of the CMC server."
::= { drsCMCServerTableEntry 5 }
drsServerNodeID OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0005.0001.0001.0006 This attribute defines the Node ID
of the CMC server. The Node ID provides a unique identifier
for the server."
::= { drsCMCServerTableEntry 6 }
-------------------------------------------------------------------------------
-- group: Chassis Alerts 1
-------------------------------------------------------------------------------
drsCASubSystem OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0020.0010.0001 This attribute defines the Sub-System Name of the CMC Alert"
::= { drsChassisAlertVariables 1 }
drsCASSCurrStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0020.0010.0002 This attribute defines the Current Status of the Alerting
Sub-System"
::= { drsChassisAlertVariables 2 }
drsCASSPrevStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0020.0010.0003 This attribute defines the Previous Status of the Alerting
Sub-System"
::= { drsChassisAlertVariables 3 }
drsCASSChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION "0020.0010.0004 This attribute defines the Timestamp of Most Recent Change of
the Alerting Sub-System"
::= { drsChassisAlertVariables 4 }
drsCAMessage OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0020.0010.0005 This attribute defines the CSSD message of the CMC Alert"
::= { drsChassisAlertVariables 5 }
alertCMCTestTrap TRAP-TYPE
ENTERPRISE drsOutofBandGroup
DESCRIPTION "The CMC has generated a test trap"
--#TYPE "CMC Test Trap"
--#SUMMARY "CMC Test Trap"
--#SEVERITY INFORMATIONAL
--#CATEGORY Error Events
::= 2000
alertCMCNormalTrap TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsProductChassisName,
drsProductChassisLocation,
drsGlobalCurrStatus,
drsCASubSystem,
drsCASSCurrStatus,
drsCASSPrevStatus,
drsCASSChangeTime,
drsCAMessage }
DESCRIPTION "The CMC reported a return-to-normal or informational event."
--#TYPE "CMC Return-to-Normal / Informational Trap"
--#SUMMARY "Return-to-Normal / Informational Trap from CMC in system %s in location %s, message: %s"
--#ARGUMENTS {0,1,7}
--#SEVERITY NORMAL
--#CATEGORY Error Events
::= 2002
alertCMCWarningTrap TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsProductChassisName,
drsProductChassisLocation,
drsGlobalCurrStatus,
drsCASubSystem,
drsCASSCurrStatus,
drsCASSPrevStatus,
drsCASSChangeTime,
drsCAMessage }
DESCRIPTION "The CMC reported a warning event."
--#TYPE "CMC Warning Trap"
--#SUMMARY "Warning Trap from CMC in system %s in location %s, message: %s"
--#ARGUMENTS {0,1,7}
--#SEVERITY WARNING
--#CATEGORY Error Events
::= 2003
alertCMCCriticalTrap TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsProductChassisName,
drsProductChassisLocation,
drsGlobalCurrStatus,
drsCASubSystem,
drsCASSCurrStatus,
drsCASSPrevStatus,
drsCASSChangeTime,
drsCAMessage }
DESCRIPTION "The CMC reported a critical event."
--#TYPE "CMC Critical Trap"
--#SUMMARY "Critical Trap from CMC in system %s in location %s, message: %s"
--#ARGUMENTS {0,1,7}
--#SEVERITY CRITICAL
--#CATEGORY Error Events
::= 2004
alertCMCNonRecoverableTrap TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsProductChassisName,
drsProductChassisLocation,
drsGlobalCurrStatus,
drsCASubSystem,
drsCASSCurrStatus,
drsCASSPrevStatus,
drsCASSChangeTime,
drsCAMessage }
DESCRIPTION "The CMC reported a catastrophic event."
--#TYPE "CMC Non-Recoverable Trap"
--#SUMMARY "Non-Recoverable Trap from CMC in system %s in location %s, message: %s"
--#ARGUMENTS {0,1,7}
--#SEVERITY NON-RECOVERABLE
--#CATEGORY Error Events
::= 2005
-------------------------------------------------------------------------------
-- group: Chassis Alerts 2
-------------------------------------------------------------------------------
drsCA2MessageID OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-only
STATUS mandatory
DESCRIPTION "Message ID of the alert."
::= { drsChassisAlert2Variables 1 }
drsCA2Message OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Message describing the alert."
::= { drsChassisAlert2Variables 2 }
drsCA2MessageArgs OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Concatenated set of strings representing any message arguments
that were used to construct the alert message. Each message
argument string is enclosed in double quotes, and there is a
comma after the ending double quote of each message argument
string, except the last one. Any double quotes found within a
message argument string were preprocessed and changed to single
quotes."
::= { drsChassisAlert2Variables 3 }
drsCA2AlertStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "Status of the alert."
::= { drsChassisAlert2Variables 4 }
drsCA2FQDD OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..512))
ACCESS read-only
STATUS mandatory
DESCRIPTION "Fully qualified device descriptor of device causing the alert."
::= { drsChassisAlert2Variables 5 }
------------------------------------------------------------------------------
-- Chassis Alerts 2: System: Amperage Probe Traps
--
-- Category: System/1
-- Subcategory: AMP/16
------------------------------------------------------------------------------
alert2AmperageProbeNormal TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Current sensor reading is within range."
--#TYPE "System: Amperage Normal"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Status Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 2179
alert2AmperageProbeWarning TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Current sensor has detected a warning value."
--#TYPE "System: Amperage Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Status Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2178
alert2AmperageProbeFailure TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Current sensor has detected a failure value."
--#TYPE "System: Amperage Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2177
------------------------------------------------------------------------------
-- Chassis Alerts 2: System: Battery Traps
--
-- Category: System/1
-- Subcategory: BAT/22
------------------------------------------------------------------------------
alert2BatteryNormal TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Battery state has returned to normal;
or battery presence had been detected."
--#TYPE "System: Battery Normal"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Status Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 2227
alert2BatteryWarning TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Battery is low."
--#TYPE "System: Battery Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Status Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2226
alert2BatteryFailure TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Battery has failed or battery is absent."
--#TYPE "System: Battery Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2225
------------------------------------------------------------------------------
-- Chassis Alerts 2: System: Cable Traps
--
-- Category: System/1
-- Subcategory: CBL/43
------------------------------------------------------------------------------
alert2CableFailure TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Cable failure."
--#TYPE "System: Cable Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2393
------------------------------------------------------------------------------
-- Chassis Alerts 2: System: CMC Traps
--
-- Category: System/1
-- Subcategory: CMC/62
------------------------------------------------------------------------------
alert2CMCWarning TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Chassis Management Controller detected a warning."
--#TYPE "System: CMC Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Status Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2546
alert2CMCFailure TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Chassis Management Controller detected an error."
--#TYPE "System: CMC Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2545
------------------------------------------------------------------------------
-- Chassis Alerts 2: System: Fan Traps
--
-- Category: System/1
-- Subcategory: FAN/13
------------------------------------------------------------------------------
alert2FanInformation TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Fan information."
--#TYPE "System: Fan Information"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Status Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 2155
alert2FanWarning TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Fan warning."
--#TYPE "System: Fan Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Status Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2154
alert2FanFailure TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Fan failure."
--#TYPE "System: Fan Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2153
------------------------------------------------------------------------------
-- Chassis Alerts 2: System: Hardware Configuration Traps
--
-- Category: System/1
-- Subcategory: HWC/35
------------------------------------------------------------------------------
alert2HardwareConfigurationInformation TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Hardware configuration information."
--#TYPE "System: Hardware Configuration Information"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Status Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 2331
alert2HardwareConfigurationWarning TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Hardware configuration warning."
--#TYPE "System: Hardware Configuration Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Status Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2330
alert2HardwareConfigurationFailure TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Hardware configuration failure or critical event."
--#TYPE "System: Hardware Configuration Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2329
------------------------------------------------------------------------------
-- Chassis Alerts 2: System: IO Virtualization Traps
--
-- Category: System/1
-- Subcategory: IOV/63
------------------------------------------------------------------------------
alert2IOVirtualizationInformation TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"IO Virtualization information."
--#TYPE "System: IO Virtualization Information"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Status Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 2555
alert2IOVirtualizationWarning TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"IO Virtualization warning."
--#TYPE "System: IO Virtualization Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Status Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2554
alert2IOVirtualizationFailure TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"IO Virtualization failure or critical event."
--#TYPE "System: IO Virtualization Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2553
------------------------------------------------------------------------------
-- Chassis Alerts 2: System: Link Status Traps
--
-- Category: System/1
-- Subcategory: LNK/25
------------------------------------------------------------------------------
alert2LinkStatusInformation TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Link status information."
--#TYPE "System: Link Status Information"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Status Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 2251
alert2LinkStatusWarning TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Link status warning."
--#TYPE "System: Link Status Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Status Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2250
alert2LinkStatusFailure TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Link status failure or critical event."
--#TYPE "System: Link Status Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2249
------------------------------------------------------------------------------
-- Chassis Alerts 2: System: PCI Device Traps
--
-- Category: System/1
-- Subcategory: PCI/46
------------------------------------------------------------------------------
alert2PCIDeviceInformation TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"PCI device information."
--#TYPE "System: PCI Device Information"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Status Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 2419
alert2PCIDeviceWarning TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"PCI device warning."
--#TYPE "System: PCI Device Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Status Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2418
alert2PCIDeviceFailure TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"PCI device failure or critical event."
--#TYPE "System: PCI Device Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2417
------------------------------------------------------------------------------
-- Chassis Alerts 2: System: Power Supply Traps
--
-- Category: System/1
-- Subcategory: PSU/17
------------------------------------------------------------------------------
alert2PowerSupplyNormal TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Power supply has returned to normal."
--#TYPE "System: Power Supply Normal"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Status Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 2187
alert2PowerSupplyWarning TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Power supply has detected a warning."
--#TYPE "System: Power Supply Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Status Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2186
alert2PowerSupplyFailure TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Power supply has detected a failure."
--#TYPE "System: Power Supply Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2185
------------------------------------------------------------------------------
-- Chassis Alerts 2: System: Power Supply Absent Traps
--
-- Category: System/1
-- Subcategory: PSUA/52
------------------------------------------------------------------------------
alert2PowerSupplyAbsent TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Power supply is absent."
--#TYPE "System: Power Supply Absent"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2465
------------------------------------------------------------------------------
-- Chassis Alerts 2: System: Power Usage Traps
--
-- Category: System/1
-- Subcategory: PWR/28
------------------------------------------------------------------------------
alert2PowerUsageInformation TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Power usage information."
--#TYPE "System: Power Usage Information"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Status Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 2275
alert2PowerUsageWarning TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Power usage warning."
--#TYPE "System: Power Usage Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Status Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2274
------------------------------------------------------------------------------
-- Chassis Alerts 2: System: Redundancy Traps
--
-- Category: System/1
-- Subcategory: RDU/53
------------------------------------------------------------------------------
alert2RedundancyInformation TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Redundancy information."
--#TYPE "System: Redundancy Information"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Status Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 2475
alert2RedundancyDegraded TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Redundancy is degraded."
--#TYPE "System: Redundancy Degraded"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Status Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2474
alert2RedundancyLost TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Redundancy is lost."
--#TYPE "System: Redundancy Lost"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2473
------------------------------------------------------------------------------
-- Chassis Alerts 2: System: Security Event Traps
--
-- Category: System/1
-- Subcategory: SEC/42
------------------------------------------------------------------------------
alert2SecurityInformation TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Security information."
--#TYPE "System: Security Information"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Status Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 2387
alert2SecurityWarning TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Security warning."
--#TYPE "System: Security Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Status Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 2386
alert2SecurityFailure TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Security failure or critical event."
--#TYPE "System: Security Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Error Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 2385
------------------------------------------------------------------------------
-- Chassis Alerts 2: System: System Event Log Traps
--
-- Category: System/1
-- Subcategory: SEL/41
------------------------------------------------------------------------------
alert2SystemEventLogInformation TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"System Event Log information."
--#TYPE "System: System Event Log Information"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Status Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 2379
alert2SystemEventLogWarning TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"System Event Log warning."
--#TYPE "System: System Event Log Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Status Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2378
alert2SystemEventLogFailure TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"System Event Log failure or critical event."
--#TYPE "System: System Event Log Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Error Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 2377
------------------------------------------------------------------------------
-- Chassis Alerts 2: System: Software Configuration Traps
--
-- Category: System/1
-- Subcategory: SWC/36
------------------------------------------------------------------------------
alert2SoftwareConfigurationInformation TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Software configuration information."
--#TYPE "System: Software Configuration Information"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Status Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 2339
alert2SoftwareConfigurationWarning TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Software configuration warning."
--#TYPE "System: Software Configuration Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Status Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2338
------------------------------------------------------------------------------
-- Chassis Alerts 2: System: Temperature Probe Traps
--
-- Category: System/1
-- Subcategory: TMP/14
------------------------------------------------------------------------------
alert2TemperatureProbeNormal TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Temperature sensor value is within range."
--#TYPE "System: Temperature Normal"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Status Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 2163
alert2TemperatureProbeWarning TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Temperature sensor has detected a warning value."
--#TYPE "System: Temperature Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Status Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2162
alert2TemperatureProbeFailure TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Temperature sensor has detected a failure value."
--#TYPE "System: Temperature Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2161
------------------------------------------------------------------------------
-- Chassis Alerts 2: System: Voltage Probe Traps
--
-- Category: System/1
-- Subcategory: VLT/15
------------------------------------------------------------------------------
alert2VoltageProbeNormal TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Voltage sensor reading is within range."
--#TYPE "System: Voltage Normal"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Status Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 2171
alert2VoltageProbeWarning TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Voltage sensor has detected a warning value."
--#TYPE "System: Voltage Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Status Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2170
alert2VoltageProbeFailure TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Voltage sensor has detected a failure value."
--#TYPE "System: Voltage Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 2169
-------------------------------------------------------------------------------
-- Chassis Alerts 2: Storage: Battery Traps
--
-- Category: Storage/2
-- Subcategory: BAT/22
-------------------------------------------------------------------------------
alert2StorageBatteryInformation TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Storage Battery information."
--#TYPE "Storage: Battery Information"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Error Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 4275
alert2StorageBatteryWarning TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Storage Battery warning."
--#TYPE "Storage: Battery Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 4274
alert2StorageBatteryFailure TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Storage Battery failure."
--#TYPE "Storage: Battery Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Error Events"
--#STATE FAILED
--#STATUS MANDATORY
::= 4273
------------------------------------------------------------------------------
-- Chassis Alerts 2: Storage: Controller Traps
--
-- Category: Storage/2
-- Subcategory: CTL/29
------------------------------------------------------------------------------
alert2StorageControllerInformation TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Storage Controller information."
--#TYPE "Storage: Controller Information"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Error Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 4331
alert2StorageControllerWarning TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Storage Controller warning."
--#TYPE "Storage: Controller Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 4330
alert2StorageControllerFailure TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Storage Controller failure."
--#TYPE "Storage: Controller Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Error Events"
--#STATE FAILED
--#STATUS MANDATORY
::= 4329
------------------------------------------------------------------------------
-- Chassis Alerts 2: Storage: Enclosure Traps
--
-- Category: Storage/2
-- Subcategory: ENC/30
------------------------------------------------------------------------------
alert2StorageEnclosureInformation TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Storage Enclosure information."
--#TYPE "Storage: Enclosure Information"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Error Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 4339
alert2StorageEnclosureWarning TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Storage Enclosure warning."
--#TYPE "Storage: Enclosure Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 4338
alert2StorageEnclosureFailure TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Storage Enclosure failure."
--#TYPE "Storage: Enclosure Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Error Events"
--#STATE FAILED
--#STATUS MANDATORY
::= 4337
------------------------------------------------------------------------------
-- Chassis Alerts 2: Storage: Fan Traps
--
-- Category: Storage/2
-- Subcategory: FAN/13
------------------------------------------------------------------------------
alert2StorageFanInformation TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Storage Fan information."
--#TYPE "Storage: Fan Information"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Error Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 4203
alert2StorageFanWarning TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Storage Fan warning."
--#TYPE "Storage: Fan Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Status Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 4202
alert2StorageFanFailure TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Storage Fan failure."
--#TYPE "Storage: Fan Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Error Events"
--#STATE FAILED
--#STATUS MANDATORY
::= 4201
------------------------------------------------------------------------------
-- Chassis Alerts 2: Storage: Physical Disk Traps
--
-- Category: Storage/2
-- Subcategory: PDR/31
------------------------------------------------------------------------------
alert2StoragePhysicalDiskInformation TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Storage Physical disk information."
--#TYPE "Storage: Physical Disk Information"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Error Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 4347
alert2StoragePhysicalDiskWarning TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Storage Physical disk warning."
--#TYPE "Storage: Physical Disk Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 4346
alert2StoragePhysicalDiskFailure TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Storage Physical disk failure."
--#TYPE "Storage: Physical Disk Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Error Events"
--#STATE FAILED
--#STATUS MANDATORY
::= 4345
------------------------------------------------------------------------------
-- Chassis Alerts 2: Storage: Power Supply Traps
--
-- Category: Storage/2
-- Subcategory: PSU/17
------------------------------------------------------------------------------
alert2StoragePowerSupplyInformation TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Storage Power supply information."
--#TYPE "Storage: Power Supply Information"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Error Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 4235
alert2StoragePowerSupplyWarning TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Storage Power supply warning."
--#TYPE "Storage: Power Supply Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 4234
alert2StoragePowerSupplyFailure TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Storage Power supply failure."
--#TYPE "Storage: Power Supply Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Error Events"
--#STATE FAILED
--#STATUS MANDATORY
::= 4233
------------------------------------------------------------------------------
-- Chassis Alerts 2: Storage: Storage Management Status Traps
--
-- Category: Storage/2
-- Subcategory: STOR/10
------------------------------------------------------------------------------
alert2StorageManagementInformation TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Storage Management information.
There is no global status change associated with this trap."
--#TYPE "Storage: Storage Management Information"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Error Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 4179
alert2StorageManagementWarning TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Storage Management has detected a device independent warning
condition. There is no global status change associated with this
trap."
--#TYPE "Storage: Storage Management Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 4178
alert2StorageManagementFailure TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Storage Management has detected a device independent error condition.
There is no global status change associated with this trap."
--#TYPE "Storage: Storage Management Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Error Events"
--#STATE FAILED
--#STATUS MANDATORY
::= 4177
------------------------------------------------------------------------------
-- Chassis Alerts 2: Storage: Temperature Probe Traps
--
-- Category: Storage/2
-- Subcategory: TMP/14
------------------------------------------------------------------------------
alert2StorageTemperatureProbeInformation TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Storage Temperature probe information."
--#TYPE "Storage: Temperature Probe Information"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Error Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 4211
alert2StorageTemperatureProbeWarning TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Storage Temperature probe warning."
--#TYPE "Storage: Temperature Probe Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 4210
alert2StorageTemperatureProbeFailure TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Storage Temperature probe failure."
--#TYPE "Storage: Temperature Probe Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Error Events"
--#STATE FAILED
--#STATUS MANDATORY
::= 4209
------------------------------------------------------------------------------
-- Chassis Alerts 2: Storage: Virtual Disk Traps
--
-- Category: Storage/2
-- Subcategory: VDR/32
------------------------------------------------------------------------------
alert2StorageVirtualDiskInformation TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Storage Virtual disk information."
--#TYPE "Storage: Virtual Disk Information"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Error Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 4355
alert2StorageVirtualDiskWarning TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Storage Virtual disk warning."
--#TYPE "Storage: Virtual Disk Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 4354
alert2StorageVirtualDiskFailure TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Storage Virtual disk failure."
--#TYPE "Storage: Virtual Disk Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Error Events"
--#STATE FAILED
--#STATUS MANDATORY
::= 4353
------------------------------------------------------------------------------
-- Chassis Alerts 2: Audit: CMC Traps
--
-- Category: Audit/4
-- Subcategory: CMC/62
------------------------------------------------------------------------------
alert2CMCAuditInformation TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Chassis Management Controller audit information."
--#TYPE "Audit: CMC Information"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Status Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 8691
alert2CMCAuditWarning TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Chassis Management Controller audit warning."
--#TYPE "Audit: CMC Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Status Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 8690
alert2CMCAuditFailure TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Chassis Management Controller audit failure or critical event."
--#TYPE "Audit: CMC Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 8689
------------------------------------------------------------------------------
-- Chassis Alerts 2: Audit: IO Virtualization Traps
--
-- Category: Audit/4
-- Subcategory: IOV/63
------------------------------------------------------------------------------
alert2IOVirtualizationAuditWarning TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"IO Virtualization audit warning."
--#TYPE "Audit: IO Virtualization Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Status Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 8698
------------------------------------------------------------------------------
-- Chassis Alerts 2: Audit: License Traps
--
-- Category: Audit/4
-- Subcategory: LIC/40
------------------------------------------------------------------------------
alert2LicenseInformation TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"License information."
--#TYPE "Audit: License Information"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Status Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 8515
alert2LicenseWarning TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"License warning."
--#TYPE "Audit: License Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Status Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 8514
alert2LicenseFailure TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"License failure."
--#TYPE "Audit: License Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 8513
------------------------------------------------------------------------------
-- Chassis Alerts 2: Audit: PCI Device Traps
--
-- Category: Audit/4
-- Subcategory: PCI/46
------------------------------------------------------------------------------
alert2PCIDeviceAuditWarning TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"PCI device audit warning."
--#TYPE "Audit: PCI Device Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Status Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 8562
------------------------------------------------------------------------------
-- Chassis Alerts 2: Audit: Power Supply Traps
--
-- Category: Audit/4
-- Subcategory: PSU/17
------------------------------------------------------------------------------
alert2PowerSupplyAuditWarning TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Power Supply audit warning."
--#TYPE "Audit: Power Supply Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Status Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 8330
alert2PowerSupplyAuditFailure TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Power Supply audit failure or critical event."
--#TYPE "Audit: Power Supply Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 8329
------------------------------------------------------------------------------
-- Chassis Alerts 2: Audit: Power Usage Traps
--
-- Category: Audit/4
-- Subcategory: PWR/28
------------------------------------------------------------------------------
alert2PowerUsageAuditWarning TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Power usage audit warning."
--#TYPE "Audit: Power Usage Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Status Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 8418
alert2PowerUsageAuditFailure TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Power usage audit failure or critical event."
--#TYPE "Audit: Power Usage Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 8417
------------------------------------------------------------------------------
-- Chassis Alerts 2: Audit: Software Change Traps
--
-- Category: Audit/4
-- Subcategory: SWU/21
------------------------------------------------------------------------------
alert2SoftwareChangeAuditFailure TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Software change audit failure or critical event."
--#TYPE "Audit: Software Change Failure"
--#SEVERITY CRITICAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Error Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 8361
------------------------------------------------------------------------------
-- Chassis Alerts 2: Configuration: IO Virtualization Traps
--
-- Category: Configuration/5
-- Subcategory: IOV/63
------------------------------------------------------------------------------
alert2IOVConfigurationInformation TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"IO Virtualization configuration information."
--#TYPE "Configuration: IO Virtualization Information"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Status Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 10747
alert2IOVConfigurationWarning TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"IO Virtualization configuration warning."
--#TYPE "Configuration: IO Virtualization Warning"
--#SEVERITY MINOR
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Status Events"
--#STATE DEGRADED
--#STATUS MANDATORY
::= 10746
------------------------------------------------------------------------------
-- Chassis Alerts 2: Configuration: PCI Device Traps
--
-- Category: Configuration/5
-- Subcategory: PCI/46
------------------------------------------------------------------------------
alert2PCIDeviceConfigurationInformation TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"PCI device configuration information."
--#TYPE "Configuration: PCI Device Information"
--#SEVERITY INFORMATIONAL
--#SUMMARY "Message ID: %s, Message: %s,"
--#SUMMARY "Device Status: %d, Device FQDD: %s,"
--#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s,"
--#SUMMARY "Chassis Location: %s, Global Status: %d"
--#ARGUMENTS {0, 1, 3, 4, 7, 5, 8}
--#CATEGORY "Status Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 10611
------------------------------------------------------------------------------
-- Chassis Alerts 2: Configuration: Test Traps
--
-- Category: Configuration/5
-- Subcategory: TST/19
------------------------------------------------------------------------------
alert2CMCTestTrap TRAP-TYPE
ENTERPRISE drsCMCAlert2Group
VARIABLES { drsCA2MessageID,
drsCA2Message,
drsCA2MessageArgs,
drsCA2AlertStatus,
drsCA2FQDD,
drsProductChassisName,
drsProductChassisLocation,
drsChassisServiceTag,
drsGlobalCurrStatus }
DESCRIPTION
"Test trap generated by CMC in response to a user request."
--#TYPE "Configuration: CMC Test Trap"
--#SEVERITY INFORMATIONAL
--#SUMMARY "%s"
--#ARGUMENTS {1}
--#CATEGORY "Status Events"
--#STATE OPERATIONAL
--#STATUS MANDATORY
::= 10395
-------------------------------------------------------------------------------
-- group: Legacy Alerts
-------------------------------------------------------------------------------
drsAlertSystem OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"5000.0010.0001 Name of the system generating the alert."
--DEFAULT get-function-async get_%n_async
--DEFAULT next-function-async std_next_async
::= { drsAlertVariables 1 }
drsAlertTableIndexOID OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"5000.0010.0002 0.0"
--DEFAULT get-function-async get_OID_null_async
--DEFAULT next-function-async std_next_async
::= { drsAlertVariables 2 }
drsAlertMessage OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..1024))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"5000.0010.0003 Message describing the alert."
--DEFAULT get-function-async get_string_null_async
--DEFAULT next-function-async std_next_async
::= { drsAlertVariables 3 }
drsAlertCurrentStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION
"5000.0010.0004 Current status of object causing the alert."
--DEFAULT get-function-async get_dellstatus_unknow_async
--DEFAULT next-function-async std_next_async
::= { drsAlertVariables 4 }
drsAlertPreviousStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION
"5000.0010.0005 Previous status of object causing the alert."
--DEFAULT get-function-async get_dellstatus_unknow_async
--DEFAULT next-function-async std_next_async
::= { drsAlertVariables 5 }
drsAlertData OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..1024))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"5000.0010.0006 Alert data."
--DEFAULT get-function-async get_string_null_async
--DEFAULT next-function-async std_next_async
::= { drsAlertVariables 6 }
alertDrscTestTrapEvent TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC generated a test trap event in response to a user request."
--#TYPE "Dell RAC Test TRAP Event"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY INFORMATIONAL
--#CATEGORY Status Events
::= 1001
alertDrscAuthError TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC Authentication Failures during a time period have Exceeded a Threshold."
--#TYPE "Dell RAC Authentication Error"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY MINOR
--#CATEGORY Error Events
::= 1002
alertDrscLostESM TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC cannot communicate with the baseboard management controller (ESM)."
--#TYPE "Dell RAC Lost Communication with ESM"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY MINOR
--#CATEGORY Error Events
::= 1003
alertDrscFoundESM TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC is communicating normally with the baseboard management controller (ESM)."
--#TYPE "Dell RAC Communication with ESM is OK"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY INFORMATIONAL
--#CATEGORY Error Events
::= 1004
alertDrscPowerOff TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC has detected a System power state change to powered-off."
--#TYPE "Dell RAC Detected System Powered-Off"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY CRITICAL
--#CATEGORY Error Events
::= 1005
alertDrscPowerOn TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC has detected a system power state change to powered-on."
--#TYPE "Dell RAC Detected System Powered-On"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY INFORMATIONAL
--#CATEGORY Error Events
::= 1006
alertDrscWatchdogExpired TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC has detected that the system watchdog has expired indicating a system hang."
--#TYPE "Dell RAC Detected Watchdog Expired"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY CRITICAL
--#CATEGORY Error Events
::= 1007
alertDrscBattLow TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC Battery charge is below 25% indicating that the battery may only be able to power the DRSC for 8-10 minutes."
--#TYPE "Dell RAC Battery Charge Low"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY MINOR
--#CATEGORY Error Events
::= 1008
alertDrscTempNormal TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC Temperature probe has retured to a normal value."
--#TYPE "Dell RAC Temperature Normal"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY INFORMATIONAL
--#CATEGORY Error Events
::= 1009
alertDrscTempWarning TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC Temperature probe has detected a Warning value."
--#TYPE "Dell RAC Temperature Warning"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY MINOR
--#CATEGORY Error Events
::= 1010
alertDrscTempCritical TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC Temperature probe has detected a failure (or critical) value."
--#TYPE "Dell RAC Temperature Failure"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY CRITICAL
--#CATEGORY Error Events
::= 1011
alertDrscVoltNormal TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC voltage has returned to a normal value."
--#TYPE "Dell RAC Voltage Normal"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY INFORMATIONAL
--#CATEGORY Error Events
::= 1012
alertDrscVoltWarning TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC voltage probe has detected a warning value."
--#TYPE "Dell RAC Battery Warning"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY MINOR
--#CATEGORY Error Events
::= 1013
alertDrscVoltCritical TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC voltage probe has detected a failure (or critical) value."
--#TYPE "Dell RAC Voltage Failure"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY CRITICAL
--#CATEGORY Error Events
::= 1014
alertDrscSELWarning TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC has detected a new event in the System Event Log with Severity: Warning."
--#TYPE "Dell RAC System Event Log Warning"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY MAJOR
--#CATEGORY Error Events
::= 1015
alertDrscSELCritical TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC has detected a new event in the System Event Log with Severity: Critical."
--#TYPE "Dell RAC System Event Log Critical"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY CRITICAL
--#CATEGORY Error Events
::= 1016
alertDrscSEL80percentFull TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC has detected that the System Event Log is 80% full."
--#TYPE "Dell System Event Log 80% Full Warning"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY MAJOR
--#CATEGORY Status Events
::= 1017
alertDrscSEL90percentFull TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC has detected that the System Event Log is 90% full."
--#TYPE " Dell System Event Log 90% Full Warning "
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY MAJOR
--#CATEGORY Status Events
::= 1018
alertDrscSEL100percentFull TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC has detected that the System Event Log is 100% full."
--#TYPE " Dell System Event Log 100% Full Warning "
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY MAJOR
--#CATEGORY Status Events
::= 1019
alertDrscSELNormal TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC has detected a new event in the System Event Log with Severity: Normal."
--#TYPE "Dell RAC System Event Log Normal"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY INFORMATIONAL
--#CATEGORY Error Events
::= 1020
END