-- NCB-8610 Private MIB
--
-- Sept. 2006, Greg Lin
--
-- Copyright (c) 2006 by Senao Technology Co., Ltd.
-- All rights reserved.
--
-- Note: This MIB file is modification 3220 private MIB.
-- It modify SNMPv2 to SNMPv1 syntax.
--
-- Date: 2006-09-20
-- *****************************************************************
--SENAO-NCB8610-MIB { iso(1) org(3) dod(6) internet(1) private(4) Enterprises(1) Senao(14125) }
--module definition
SENAO-WLAN-CB-MIB DEFINITIONS ::= BEGIN
IMPORTS
enterprises, IpAddress FROM RFC1155-SMI
DisplayString, PhysAddress FROM RFC1213-MIB
OBJECT-TYPE FROM RFC-1212
TRAP-TYPE FROM RFC-1215
mgmt, NetworkAddress, IpAddress, Counter, Gauge,
TimeTicks FROM RFC1155-SMI;
-- SENAO-Private-MIB DEFINITIONS --
senaoMIB OBJECT IDENTIFIER ::= { enterprises 14125 }
-- SENAO-RFC1213-MIB DEFINITIONS --
senaoRFC1213Group OBJECT IDENTIFIER ::= { senaoMIB 1 }
-- SENAO-Private-MIB DEFINITIONS --
statusInformationGroup OBJECT IDENTIFIER ::= { senaoMIB 2 }
countersGroup OBJECT IDENTIFIER ::= { senaoMIB 3 }
privacySettingsGroup OBJECT IDENTIFIER ::= { senaoMIB 4 }
systemSettingsGroup OBJECT IDENTIFIER ::= { senaoMIB 5 }
webAdministratorSettingsGroup OBJECT IDENTIFIER ::= { senaoMIB 6 }
-- SENAO-RFC1213-MIB DEFINITIONS --
ip OBJECT IDENTIFIER ::= { senaoRFC1213Group 1 }
icmp OBJECT IDENTIFIER ::= { senaoRFC1213Group 2 }
tcp OBJECT IDENTIFIER ::= { senaoRFC1213Group 3 }
udp OBJECT IDENTIFIER ::= { senaoRFC1213Group 4 }
-- SENAO-Private-MIB DEFINITIONS --
-- [ statusInformationGroup ] [1] --
connectedToSSID OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute reflects the Service Set ID.
This value may be modified by an external management
entity and used by the local SME to make decisions
about the Scanning process. The connectedToSSID
length is limit between 1~ 32 characters.
@GET-FUNC=get_statusInfo_group
@SET-FUNC=set_statusInfo_group"
::= { statusInformationGroup 1 }
usingChannel OBJECT-TYPE
SYNTAX INTEGER
{
-- Note: the SNMPv1 does not support channel array so chang channelX
channel1 (1),
channel2 (2),
channel3 (3),
channel4 (4),
channel5 (5),
channel6 (6),
channel7 (7),
channel8 (8),
channel9 (9),
channel10 (10),
channel11 (11)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The operating frequency channel. Valid numbers
are as defind in ISO/IEC 8802-11:1999, 15.4.6.2.
@GET-FUNC=get_statusInfo_group"
::= { statusInformationGroup 2 }
-- (CB)
clientBridgeMACAddress OBJECT-TYPE
SYNTAX PhysAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The purpose of clientBridgeMACAddress is to allow a manager to identify
a station for its own purposes. This attribute provides
for that eventuality while keeping the true MAC address
independent. Its syntax is MAC address and default value
is the station's assigned, unique MAC address.
@GET-FUNC=get_statusInfo_group"
::= { statusInformationGroup 3 }
currentIPAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The IP address of this device used over its Ethernet
interface in Routing mode or Bridge interface in Bridgeing mode.
@GET-FUNC=get_statusInfo_group"
::= { statusInformationGroup 4 }
-- (CB)
linkUpIndicator OBJECT-TYPE
SYNTAX INTEGER
-- Error: number enumeration contains zero value in SMIv1 MIB
--{
-- offLine(0),
-- onLine(1)
--}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The operated state of the wireless interface. The
onLine(1) state indicates that this device connected
to Access Point.
@GET-FUNC=get_statusInfo_group"
::= { statusInformationGroup 5 }
clientSignalStrength OBJECT-TYPE
SYNTAX INTEGER (0..100)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A device-dependent measure of the signal strength(%) of the
most recently received packet from this Station.
@GET-FUNC=get_statusInfo_group"
::= { statusInformationGroup 6 }
clientAssociationTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The time since this device connected to Access Point.
@GET-FUNC=get_statusInfo_group"
::= { statusInformationGroup 7 }
currentTXPower OBJECT-TYPE
SYNTAX INTEGER
{
-- Transmit Power Level
high (1),
medium (2),
low (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Transmit Power of this device used.
@GET-FUNC=get_statusInfo_group
@SET-FUNC=set_statusInfo_group"
::= { statusInformationGroup 8 }
-- [ countersGroup ] [2] --
receivedPacketsGoodCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of good packets received on the radio interface,
including unicast, broadcast and multicast packets.
@GET-FUNC=get_counters_group"
::= { countersGroup 1 }
receivedPacketsBadCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of inbound bad packets of the radio interface
were chosen to be discarded even though no errors had been
detected to prevent their being received. One possible reason
for discarding such a packet could be to free up buffer space.
Another reason would be exceeding their maximum time-to-live.
@GET-FUNC=get_counters_group"
::= { countersGroup 2 }
sendPacketsGoodCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of good packets transmitted on the radio interface,
including unicast, broadcast and multicast packets.
@GET-FUNC=get_counters_group"
::= { countersGroup 3 }
sendPacketsBadCount OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of outbound bad packets of the radio interface
were chosen to be discarded even though no errors had been
detected to prevent their being transmitted. One possible reason
for discarding such a packet could be to free up buffer space.
Another reason would be exceeding their maximum time-to-live.
@GET-FUNC=get_counters_group"
::= { countersGroup 4 }
-- [ privacySettingsGroup ] [3] --
wepEnabled OBJECT-TYPE
SYNTAX INTEGER
{
disable(1),
enable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When this attribute is enable, it shall indicate that the IEEE
802.11 WEP mechanism is used for transmitting frames of type
Data. The default value of this attribute shall be disable.
@GET-FUNC=get_privacy_group
@SET-FUNC=set_privacy_group"
::= { privacySettingsGroup 1 }
wepKeyLength OBJECT-TYPE
SYNTAX INTEGER
{
key-64bits(1),
key-128bits(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The length of WEP key that is used for transmitting and received
frames of type Data. The value of 0 denotes WEP64bit Hex. Key;
1 stands for WEP128bit Hex. Key
@GET-FUNC=get_privacy_group
@SET-FUNC=set_privacy_group"
::= { privacySettingsGroup 2 }
wepKeyNumber OBJECT-TYPE
SYNTAX INTEGER
{
wep-key1(1),
wep-key2(2),
wep-key3(3),
wep-key4(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute shall indicate the use of the first,
second, third, or fourth element of the WEPDefaultKeys
array when set to values of 1, 2, 3, or 4. The
default value of this attribute shall be 0.
@GET-FUNC=get_privacy_group
@SET-FUNC=set_privacy_group"
-- REFERENCE "IEEE Std 802.11-1997, 8.3.2"
::= { privacySettingsGroup 3 }
wepKey OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A WEP secret key value. 10 Hex. Keys for WEP 64Bits/26 Hex. Keys for WEP128Bits.
@GET-FUNC=get_privacy_group
@SET-FUNC=set_privacy_group"
::= { privacySettingsGroup 4 }
-- [ systemSettingsGroup ] [4] --
operationMode OBJECT-TYPE
SYNTAX INTEGER
{
bridge(1),
ap-wds(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This defines the type of role of a wireless device.
The device types are:
Bridge(1) -- Bridge
AP+WDS(2) -- Access Point+WDS
@GET-FUNC=get_system_group"
::= { systemSettingsGroup 1 }
ipAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IP address of this device used over its Ethernet
interface in CB mode. The IP address must NOT set
[x.x.x.0] or [x,x.x.255].
@GET-FUNC=get_system_group
@SET-FUNC=set_system_group"
::= { systemSettingsGroup 2 }
subnetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IP Network mask used by the IP entity when accessing
devices through any of its Ethernet interface in Routing mode
or Bridge interface in Bridgeing mode.
The value of subnet mask must set to 0, 128, 192, 224, 240, 248, 252, 254, 255.
@GET-FUNC=get_system_group
@SET-FUNC=set_system_group"
::= { systemSettingsGroup 3 }
ipGateway OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IP address of this device's Gateway.
The value of IP Gateway must NOT set to 0 or 255
@GET-FUNC=get_system_group
@SET-FUNC=set_system_group"
::= { systemSettingsGroup 4 }
deviceName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The description name of this device.
The deviceName length is limit between
1~32 characters.
@GET-FUNC=get_system_group
@SET-FUNC=set_system_group"
::= { systemSettingsGroup 5 }
-- desiredSSID OBJECT-TYPE
-- SYNTAX OCTET STRING
-- ACCESS read-write
-- STATUS mandatory
-- DESCRIPTION
-- "The Preferred Service Set ID used in the most recent MLME_Scan.request.
-- This value may be modified by an external management entity and used by
-- the local SME to make decisions about the Scanning process.
-- @GET-FUNC=get_system_group
-- @SET-FUNC=set_system_group"
-- ::= { systemSettingsGroup 6 }
saveReboot OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Save and Reboot System
The save Reboot value must set to 1 when you enable this function.
@GET-FUNC=get_system_group
@SET-FUNC=set_system_group"
::= { systemSettingsGroup 6 }
-- [ webAdministratorSettingsGroup ] [5] --
userName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User Name assigned to the system for use when
authenticating with Web browser. The username length
limit is 15 characters.
@GET-FUNC=get_webAdmin_group
@SET-FUNC=set_webAdmin_group"
::= { webAdministratorSettingsGroup 1}
password OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User Password assigned to the system
for use when authenticating with Web browser. The
password length limit is 15 characters.
@GET-FUNC=get_webAdmin_group
@SET-FUNC=set_webAdmin_group"
::= { webAdministratorSettingsGroup 2}
-- SENAO-RFC1213-MIB DEFINITIONS --
-- the IP group
-- Implementation of the IP group is mandatory for all
-- systems.
ipInReceives OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of input datagrams received from
interfaces, including those received in error.
@GET-FUNC=get_ip_row"
::= { ip 1 }
ipForwDatagrams OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of input datagrams for which this
entity was not their final IP destination, as a
result of which an attempt was made to find a
route to forward them to that final destination.
In entities which do not act as IP Gateways, this
counter will include only those packets which were
Source-Routed via this entity, and the Source-
Route option processing was successful.
@GET-FUNC=get_ip_row"
::= { ip 2 }
-- the ICMP group
-- Implementation of the ICMP group is mandatory for all
-- systems.
icmpInMsgs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of ICMP messages which the
entity received. Note that this counter includes
all those counted by icmpInErrors.
@GET-FUNC=get_icmp_row"
::= { icmp 1 }
icmpOutMsgs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of ICMP messages which this
entity attempted to send. Note that this counter
includes all those counted by icmpOutErrors.
@GET-FUNC=get_icmp_row"
::= { icmp 2 }
-- the TCP group
-- Implementation of the TCP group is mandatory for all
-- systems that implement the TCP.
-- Note that instances of object types that represent
-- information about a particular TCP connection are
-- transient; they persist only as long as the connection
-- in question.
tcpInSegs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of segments received, including
those received in error. This count includes
segments received on currently established
connections.
@GET-FUNC=get_tcp_row"
::= { tcp 1 }
tcpOutSegs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of segments sent, including
those on current connections but excluding those
containing only retransmitted octets.
@GET-FUNC=get_tcp_row"
::= { tcp 2 }
-- the UDP group
-- Implementation of the UDP group is mandatory for all
-- systems which implement the UDP.
udpInDatagrams OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of UDP datagrams delivered to
UDP users.
@GET-FUNC=get_udp_row"
::= { udp 1 }
udpOutDatagrams OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of UDP datagrams sent from this
entity.
@GET-FUNC=get_udp_row"
::= { udp 2 }
END