-- Title: FICON MIB
-- This is in accordance with smiv2 format.
-- Intial version 1.0
--
LINK-INCIDENT-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,
Integer32, OBJECT-IDENTITY, NOTIFICATION-TYPE
FROM SNMPv2-SMI
TEXTUAL-CONVENTION, DisplayString
FROM SNMPv2-TC
fcSwitch
FROM Brocade-REG-MIB;
linkIncidentMIB MODULE-IDENTITY
LAST-UPDATED "200204232347Z"
ORGANIZATION "Brocade Communications Systems, Inc.,"
CONTACT-INFO "Customer Support Group
Brocade Communications Systems,
1745, Technology Drive,
San Jose, CA 95110 U.S.A
Tel: +1-408-392-6061
Fax: +1-408-392-6656
Email: support@Brocade.COM
WEB: www.brocade.com"
DESCRIPTION "The MIB module defines support for FICON in Fabos. This MIB
addresses link incident and link failure data for ficon
host/devices connected to a Brocade switch"
REVISION "200307110000Z" -- July 11, 2003
DESCRIPTION "Initial revision"
::= { fcSwitch 50 }
-- Textual conventions
FcPortID ::= TEXTUAL-CONVENTION
DISPLAY-HINT "x"
STATUS current
DESCRIPTION "Represents Fibre Channel Address ID, a 24-bit
value unique within the address space of a Fabric."
SYNTAX OCTET STRING (SIZE (3))
RLIRLinkFailureType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Represents the link failure type"
SYNTAX INTEGER {
bitErrorRate(2),
lossOfSignal(3),
nOSRecognized(4),
primitiveSequenceTimeout(5),
invalidSeqForPortState(6),
loopInitializationTimeout(7),
lossOfSignalInLoopInit(8)
}
LinkWwn ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Represents the link WWN"
SYNTAX OCTET STRING (SIZE (8))
PortType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Represents the Port Type"
SYNTAX INTEGER {
n-port (1),
nl-port (2)
}
LinkFormat ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Represents the frame format"
SYNTAX INTEGER {
ficon(1),
common(2)
}
RegType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Represents the RNID Registration Type"
SYNTAX INTEGER {
conditional (1),
unconditional (2)
}
LIRRProtocol ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Represents the LIRR Protocol"
SYNTAX INTEGER {
fcp (1),
sb2 (2)
}
RNIDTagType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "x"
STATUS current
DESCRIPTION "Represents the value of RNID Tag in Hexa Decimal format"
SYNTAX OCTET STRING (SIZE (2))
RNIDFlags ::= TEXTUAL-CONVENTION
DISPLAY-HINT "x"
STATUS current
DESCRIPTION "Represents the value of RNID Flag in Hexa Decimal format.
It indicates if the node is valid, not valid, or
not current. The ``Flag'' values also indi-
cate the following:
0x00 Indicates node ID of the
(storage port for RNID, switch
for SwitchRNID) is valid.
0x10 Indicates node ID of the chan-
nel port is valid.
0x20 Indicates the node ID of the
storage port is not current.
0x30 Indicates the node ID of the
channel port is not current.
0x40 Indicates the the node ID of
the (storage port for RNID,
switch for RLIR) is not valid.
0x50 Indicates the node ID of the
channel port is not valid."
SYNTAX OCTET STRING (SIZE(1))
RNIDType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Represents the value of Type Number - Displays the type
number of the self describing node. It also describes
the machine type."
SYNTAX OCTET STRING (SIZE (6))
RNIDModel ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Represents the value of Model Number."
SYNTAX OCTET STRING (SIZE (3))
RNIDManufacturer ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Represents the Manufacturer name or code."
SYNTAX OCTET STRING (SIZE (3))
RNIDManufacturerPlant ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "The manufacture plant name or code."
SYNTAX OCTET STRING (SIZE (2))
RNIDSequenceNumber ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Sequence number of the self describing node."
SYNTAX OCTET STRING (SIZE (12))
RNIDParams ::= TEXTUAL-CONVENTION
DISPLAY-HINT "x"
STATUS current
DESCRIPTION "Represents the value of Param.
It is the incident node parameters type in
three bytes: ``0xAABBCC''. The meaning of
each byte is described below:
Byte AA:
0x00 Reserved
0x20 FC-SB-2 and updates.
0x40 Other FC-4s including FCP and
updates.
0x60 FC-SB-2 and updates and other
FC-4s including FCP and
updates.
0x80 FC-4 support not specified.
0xa0 Reserved.
0xc0 Reserved.
0xe0 Vendor specific.
Byte BB:
0x00 Unspecified class
0x01 Direct access storage device,
if it is an storage port.
Otherwise, it is not channel
to channel capable.
0x02 Magnetic tape, if it is an
storage port. Otherwise, if it
is a reserved field for a
channel port.
0x03 Input unit record, if it is an
storage port. Otherwise, it is
a reserved field for a channel
port.
0x04 Output unit, if it is an stor-
age port. Otherwise, it is a
reserved field for a channel
port.
0x05 Printer, if it is an storage
port. Otherwise, it is a
reserved field for a channel
port.
0x06 Controler, if it is an storage
port. Otherwise, it is a
reserved field for a channel
port.
0x07 Terminal - Full screen if it
is an storage port. Otherwise,
it is a reserved field for a
channel port.
0x08 Terminal - Line mode if it is
an storage port. Otherwise,
it is an emulated control unit
support only.
0x09 Reserved.
0x10 Switch, if it is a switch
device. Otherwise, it is
reserved.
0x0b 0xff Reserved.
Byte CC:
0x00 If storage CU port has regis-
tered with the switch.
0xID CHIPID if channel port has
registered with the switch.
0xPN If switch has registered with
the channel then PN represent
the FL port number."
SYNTAX OCTET STRING (SIZE (3))
-- { linkIncidentMIB 1 } is reserved for future usage.
ficonRNID OBJECT-IDENTITY
STATUS current
DESCRIPTION "The OID sub-tree for ficonRNID. This group contains all
RNID group objects for FICON."
::= { linkIncidentMIB 2 }
nodeRNIDTableNumEntries OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of entries in Request Node Identification Data (RNID) table."
::= { ficonRNID 1 }
-- node RNID table
-- Node information from attached node to the switch are stored
-- in the node RNID table
nodeRNIDTable OBJECT-TYPE
SYNTAX SEQUENCE OF NodeRNIDEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains, one entry for each Ficon RNID
node attached to a switch."
::= { ficonRNID 2 }
nodeRNIDEntry OBJECT-TYPE
SYNTAX NodeRNIDEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A entry containing the RNID information
for a ficon node"
INDEX { nodeRNIDIndex }
::= { nodeRNIDTable 1 }
NodeRNIDEntry ::= SEQUENCE {
nodeRNIDIndex
Integer32,
nodeRNIDIncidentPortWWN
LinkWwn,
nodeRNIDPID
FcPortID,
nodeRNIDFlags
RNIDFlags,
nodeRNIDType
RNIDType,
nodeRNIDModel
RNIDModel,
nodeRNIDManufacturer
RNIDManufacturer,
nodeRNIDManufacturerPlant
RNIDManufacturerPlant,
nodeRNIDSequenceNumber
RNIDSequenceNumber,
nodeRNIDConnectedPortWWN
LinkWwn,
nodeRNIDPortType
PortType,
nodeRNIDFormat
LinkFormat,
nodeRNIDTag
RNIDTagType,
nodeRNIDParams
RNIDParams
}
nodeRNIDIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index into nodeRNIDTable"
::= { nodeRNIDEntry 1 }
nodeRNIDIncidentPortWWN OBJECT-TYPE
SYNTAX LinkWwn
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Port WWN for Incident port. An N-port (ficon device
or host) is an incident port"
::= { nodeRNIDEntry 2 }
nodeRNIDPID OBJECT-TYPE
SYNTAX FcPortID
MAX-ACCESS read-only
STATUS current
DESCRIPTION "PID for an Incident port."
::= { nodeRNIDEntry 3 }
nodeRNIDFlags OBJECT-TYPE
SYNTAX RNIDFlags
MAX-ACCESS read-only
STATUS current
DESCRIPTION "RNID flags for an Incident port."
::= { nodeRNIDEntry 4 }
nodeRNIDType OBJECT-TYPE
SYNTAX RNIDType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number associate with a node"
::= { nodeRNIDEntry 5 }
nodeRNIDModel OBJECT-TYPE
SYNTAX RNIDModel
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Model number of the RNID node"
::= { nodeRNIDEntry 6 }
nodeRNIDManufacturer OBJECT-TYPE
SYNTAX RNIDManufacturer
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Identifies the manufaturer of the node."
::= { nodeRNIDEntry 7 }
nodeRNIDManufacturerPlant OBJECT-TYPE
SYNTAX RNIDManufacturerPlant
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Identifies the manufacturer plant of the node."
::= { nodeRNIDEntry 8 }
nodeRNIDSequenceNumber OBJECT-TYPE
SYNTAX RNIDSequenceNumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Identifies the sequence number of the node."
::= { nodeRNIDEntry 9 }
nodeRNIDConnectedPortWWN OBJECT-TYPE
SYNTAX LinkWwn
MAX-ACCESS read-only
STATUS current
DESCRIPTION "WWN of the connected port."
::= { nodeRNIDEntry 10 }
nodeRNIDPortType OBJECT-TYPE
SYNTAX PortType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Port type (N, NL or virtual port) of the connected port."
::= { nodeRNIDEntry 11 }
nodeRNIDFormat OBJECT-TYPE
SYNTAX LinkFormat
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Node identification data format of the connected port."
::= { nodeRNIDEntry 12 }
nodeRNIDTag OBJECT-TYPE
SYNTAX RNIDTagType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Node identification tag of the connected port."
::= { nodeRNIDEntry 13 }
nodeRNIDParams OBJECT-TYPE
SYNTAX RNIDParams
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Node parameters of the connected port."
::= { nodeRNIDEntry 14 }
switchRNIDTableNumEntries OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of entries in RNID table which corresponds to switch."
::= { ficonRNID 3 }
-- switchRNIDTable - This table contains the RNID info. for the
-- switch node. Normally, there will be only one entry in the table.
switchRNIDTable OBJECT-TYPE
SYNTAX SEQUENCE OF SwitchRNIDEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains, one entry for each switch ficon node."
::= { ficonRNID 4 }
switchRNIDEntry OBJECT-TYPE
SYNTAX SwitchRNIDEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX { switchRNIDIndex }
::= { switchRNIDTable 1 }
SwitchRNIDEntry ::= SEQUENCE {
switchRNIDIndex Integer32,
switchRNIDSwitchWWN
LinkWwn,
switchRNIDFlags
RNIDFlags,
switchRNIDType
RNIDType,
switchRNIDModel
RNIDModel,
switchRNIDManufacturer
RNIDManufacturer,
switchRNIDManufacturerPlant
RNIDManufacturerPlant,
switchRNIDSequenceNumber
RNIDSequenceNumber,
switchRNIDTag
RNIDTagType,
switchRNIDParams
RNIDParams
}
switchRNIDIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Index into switchRNIDTable."
::= { switchRNIDEntry 1 }
switchRNIDSwitchWWN OBJECT-TYPE
SYNTAX LinkWwn
MAX-ACCESS read-only
STATUS current
DESCRIPTION "WWN of the switch."
::= { switchRNIDEntry 2 }
switchRNIDFlags OBJECT-TYPE
SYNTAX RNIDFlags
MAX-ACCESS read-only
STATUS current
DESCRIPTION "RNID flags for switch."
::= { switchRNIDEntry 3 }
switchRNIDType OBJECT-TYPE
SYNTAX RNIDType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Type Number associate with a switch."
::= { switchRNIDEntry 4 }
switchRNIDModel OBJECT-TYPE
SYNTAX RNIDModel
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Model number of the RNID switch."
::= { switchRNIDEntry 5 }
switchRNIDManufacturer OBJECT-TYPE
SYNTAX RNIDManufacturer
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Identifies the manufaturer of the switch."
::= { switchRNIDEntry 6 }
switchRNIDManufacturerPlant OBJECT-TYPE
SYNTAX RNIDManufacturerPlant
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Identifies the manufacturer plant of the switch."
::= { switchRNIDEntry 7 }
switchRNIDSequenceNumber OBJECT-TYPE
SYNTAX RNIDSequenceNumber
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Identifies the sequence number of the switch."
::= { switchRNIDEntry 8 }
switchRNIDTag OBJECT-TYPE
SYNTAX RNIDTagType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Identification tag of the switch."
::= { switchRNIDEntry 9 }
switchRNIDParams OBJECT-TYPE
SYNTAX RNIDParams
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Parameters of the switch."
::= { switchRNIDEntry 10 }
nodeVfId OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Virtual fabric id of the switch. For VF unaware switches
this value will be 0."
::= { ficonRNID 5 }
-- LIRRTable - This group contains LIRR info for each listener port.
ficonLIRR OBJECT-IDENTITY
STATUS current
DESCRIPTION "The OID sub-tree for ficonLIRR. This group contains all
LIRR group objects for FICON."
::= { linkIncidentMIB 3 }
lIRRTableNumEntries OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of entries in Link Incident Record
Registration (LIRR) table"
::= { ficonLIRR 1 }
lIRRTable OBJECT-TYPE
SYNTAX SEQUENCE OF LIRREntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains, one entry for each LIRR incident
for an attached FICON device."
::= { ficonLIRR 2 }
lIRREntry OBJECT-TYPE
SYNTAX LIRREntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry containing LIRR information."
INDEX { lIRRIndex }
::= { lIRRTable 1 }
LIRREntry ::= SEQUENCE {
lIRRIndex
Integer32,
lIRRListenerPortWWN
LinkWwn,
lIRRListenerPID
FcPortID,
lIRRRegType
RegType,
lIRRProtocol
LIRRProtocol,
lIRRPortType
PortType,
lIRRFormat
LinkFormat
}
lIRRIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Index into the LIRR table."
::= { lIRREntry 1 }
lIRRListenerPortWWN OBJECT-TYPE
SYNTAX LinkWwn
MAX-ACCESS read-only
STATUS current
DESCRIPTION "WWN of the Listener port."
::= { lIRREntry 2 }
lIRRListenerPID OBJECT-TYPE
SYNTAX FcPortID
MAX-ACCESS read-only
STATUS current
DESCRIPTION "PID for the listener port."
::= { lIRREntry 3 }
lIRRRegType OBJECT-TYPE
SYNTAX RegType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Registration type - conditional or unconditional."
::= { lIRREntry 4 }
lIRRProtocol OBJECT-TYPE
SYNTAX LIRRProtocol
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Protocol type supported."
::= { lIRREntry 5 }
lIRRPortType OBJECT-TYPE
SYNTAX PortType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Attached port type."
::= { lIRREntry 6 }
lIRRFormat OBJECT-TYPE
SYNTAX LinkFormat
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Registration type - conditional or unconditional."
::= { lIRREntry 7 }
-- RLIR group - This group contains RLIR info. for each link incident"
ficonRLIR OBJECT-IDENTITY
STATUS current
DESCRIPTION "The OID sub-tree for ficonRLIR. This group contains all
RLIR group objects for FICON."
::= { linkIncidentMIB 4 }
rLIRTableNumEntries OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of entries in switch Registered Link
Incident Report (RLIR) table"
::= { ficonRLIR 1 }
rLIRTable OBJECT-TYPE
SYNTAX SEQUENCE OF RLIREntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains, one entry for each LIRR incident
for an attached FICON device."
::= { ficonRLIR 2 }
rLIREntry OBJECT-TYPE
SYNTAX RLIREntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry containing RLIR information."
INDEX { rLIRIndex }
::= { rLIRTable 1 }
RLIREntry ::= SEQUENCE {
rLIRIndex Integer32,
rLIRIncidentPortWwn LinkWwn,
rLIRIncidentNodeWwn LinkWwn,
rLIRIncidentPortType PortType,
rLIRIncidentPID FcPortID,
rLIRIncidentPortNumber Integer32,
rLIRConnectedPortWwn LinkWwn,
rLIRConnectedNodeWwn LinkWwn,
rLIRFabricWwn LinkWwn,
rLIRLinkFailureType RLIRLinkFailureType,
rLIRTimeStamp DisplayString,
rLIRFormat LinkFormat
}
rLIRIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Index into RLIR table."
::= { rLIREntry 1 }
rLIRIncidentPortWwn OBJECT-TYPE
SYNTAX LinkWwn
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Port WWN for RLIR Incident port."
::= { rLIREntry 2 }
rLIRIncidentNodeWwn OBJECT-TYPE
SYNTAX LinkWwn
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Incident node WWN."
::= { rLIREntry 3 }
rLIRIncidentPortType OBJECT-TYPE
SYNTAX PortType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "RLIR Incident port type."
::= { rLIREntry 5 }
rLIRIncidentPID OBJECT-TYPE
SYNTAX FcPortID
MAX-ACCESS read-only
STATUS current
DESCRIPTION "RLIR Incident PID."
::= { rLIREntry 6 }
rLIRIncidentPortNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "RLIR Incident port number.This is vendor specific
port number."
::= { rLIREntry 7 }
rLIRConnectedPortWwn OBJECT-TYPE
SYNTAX LinkWwn
MAX-ACCESS read-only
STATUS current
DESCRIPTION "RLIR Connected port WWN."
::= { rLIREntry 8 }
rLIRConnectedNodeWwn OBJECT-TYPE
SYNTAX LinkWwn
MAX-ACCESS read-only
STATUS current
DESCRIPTION "RLIR Connected node WWN."
::= { rLIREntry 9 }
rLIRFabricWwn OBJECT-TYPE
SYNTAX LinkWwn
MAX-ACCESS read-only
STATUS current
DESCRIPTION "RLIR Fabric Wwn."
::= { rLIREntry 10 }
rLIRLinkFailureType OBJECT-TYPE
SYNTAX RLIRLinkFailureType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "RLIR Link failure type."
::= { rLIREntry 11 }
rLIRTimeStamp OBJECT-TYPE
SYNTAX DisplayString(SIZE (0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "RLIR time stamp."
::= { rLIREntry 12 }
rLIRFormat OBJECT-TYPE
SYNTAX LinkFormat
MAX-ACCESS read-only
STATUS current
DESCRIPTION "RLIR Format."
::= { rLIREntry 13 }
-- { linkIncidentMIB 5..20 } are reserved for new mib objects in future.
-- Related traps
linkIncidentMIBTraps OBJECT-IDENTITY
STATUS current
DESCRIPTION "The OID sub-tree for Link Incident trap."
::= { linkIncidentMIB 21 }
linkIncidentMIBTrapPrefix OBJECT-IDENTITY
STATUS current
DESCRIPTION "The Link Incident traps."
::= { linkIncidentMIBTraps 0 }
linkRNIDDeviceRegistration NOTIFICATION-TYPE
OBJECTS { nodeRNIDIndex, nodeRNIDIncidentPortWWN, nodeRNIDConnectedPortWWN, nodeVfId }
STATUS current
DESCRIPTION
" A device registered with the switch"
::= {linkIncidentMIBTrapPrefix 1}
linkRNIDDeviceDeRegistration NOTIFICATION-TYPE
OBJECTS { nodeRNIDIndex, nodeRNIDIncidentPortWWN, nodeRNIDConnectedPortWWN, nodeVfId }
STATUS current
DESCRIPTION
" A device de-regsitered with the switch"
::= {linkIncidentMIBTrapPrefix 2}
linkLIRRListenerAdded NOTIFICATION-TYPE
OBJECTS {lIRRListenerPortWWN, lIRRListenerPID, lIRRIndex, nodeVfId}
STATUS current
DESCRIPTION
" A listener for link failure incident is added"
::= {linkIncidentMIBTrapPrefix 3}
linkLIRRListenerRemoved NOTIFICATION-TYPE
OBJECTS {lIRRListenerPortWWN, lIRRListenerPID, lIRRIndex, nodeVfId}
STATUS current
DESCRIPTION
" A listener for link failure incident is removed"
::= {linkIncidentMIBTrapPrefix 4}
linkRLIRFailureIncident NOTIFICATION-TYPE
OBJECTS { nodeRNIDIndex, lIRRIndex, rLIRIncidentPortWwn,
rLIRConnectedPortWwn,
rLIRIndex, rLIRLinkFailureType, lIRRListenerPID, nodeVfId }
STATUS current
DESCRIPTION
" A link failure incident has occured. The value of
lIRRIndex will be -2147483647 and lIRRListenerPID will
be 0 (zero) , if there is no listener for incident."
::= {linkIncidentMIBTrapPrefix 5}
END