"rule": "%macros.device_down = \"1\"",
"name": "Devices up/down",
"default": true
},
{
"rule": "%devices.uptime < \"300\" && %macros.device = \"1\"",
"name": "Device rebooted",
"extra": "{\"count\": 1}",
"default": true
},
{
"rule": "%bgpPeers.bgpPeerState != \"established\" && %macros.device_up = \"1\"",
"name": "BGP Session down",
"extra": "{\"count\": 1}",
"default": true
},
{
"rule": "%bgpPeers.bgpPeerFsmEstablishedTime < \"300\" && %bgpPeers.bgpPeerState = \"established\" && %macros.device_up = \"1\"",
"name": "BGP Session established",
"extra": "{\"count\": 1}",
"default": true
},
{
"rule": "%macros.port_down = \"1\"",
"name": "Port status up/down",
"extra": "{\"count\": 1}",
"default": true
},
{
"rule": "%macros.port_usage_perc >= \"80\" && %macros.port_up = \"1\" && %macros.port = \"1\"",
"name": "Port utilisation over threshold",
"default": true
},
{
"rule": "%sensors.sensor_current > %sensors.sensor_limit && %sensors.sensor_alert = \"1\" && %macros.device_up = \"1\"",
"name": "Sensor over limit",
"default": true
},
{
"rule": "%sensors.sensor_current < %sensors.sensor_limit_low && %sensors.sensor_alert = \"1\" && %macros.device_up = \"1\"",
"name": "Sensor under limit",
"default": true
},
{
"rule": "%services.service_status != \"0\" && %macros.device_up = \"1\"",
"name": "Service up/down",
"default": true
},
{
"rule": "%wireless_sensors.sensor_current >= %wireless_sensors.sensor_limit && %wireless_sensors.sensor_alert = \"1\" && %macros.device_up = \"1\"",
"name": "Wireless Sensor over limit",
"default": true
},
{
"rule": "%wireless_sensors.sensor_current <= %wireless_sensors.sensor_limit_low && %wireless_sensors.sensor_alert = \"1\" && %macros.device_up = \"1\"",
"name": "Wireless Sensor under limit",
"default": true
},
{
"rule": "%macros.bill_quota_over_quota >= \"75\"",
"name": "Quota bills over 75% used"
},
{
"rule": "%macros.bill_cdr_over_quota >= \"75\"",
"name": "CDR bills over 75% used"
},
{
"rule": "%ipsec_tunnels.tunnel_status != \"active\" && %macros.device_up = \"1\"",
"name": "IPSec tunnels down"
},
{
"rule": "%pollers.time_taken >= \"250\"",
"name": "Poller is taking too long"
},
{
"rule": "%macros.device_up = \"1\" && %devices.os = \"asa\" && %ciscoASA.data > \"5000\"",
"name": "Cisco ASA connections over 5000"
},
{
"rule": "%processors.processor_usage > \"85\" && %macros.device_up = \"1\"",
"name": "Processor usage over 85%"
},
{
"rule": "%sensors.sensor_descr = \"Primary Unit.*\" && %sensors.sensor_current = \"10\" && %sensors.sensor_prev = \"9\"",
"name": "Cisco ASA Primary unit changed to standby"
},
{
"rule": "%ports.ifOperStatus = \"down\" && %ports.ifOperStatus_prev = \"up\" && %macros.device_up = \"1\"",
"name": "Port status change from up to down"
},
{
"rule": "%ports.ifOutErrors_rate >= \"100\" || %ports.ifInErrors_rate >= \"100\"",
"name": "Interface Errors Rate greater than 100"
},
{
"rule": "%eventlog.type = \"discovery\" && %eventlog.message ~ \"@autodiscovered@\" && %eventlog.datetime >= %macros.past_60m",
"name": "Device discovered within the last 60 minutes"
},
{
"rule": "%wireless_sensors.sensor_class = 'clients' && %wireless_sensors.sensor_current >= %wireless_sensors.sensor_limit && %wireless_sensors.sensor_alert = \"1\" && %macros.device_up = \"1\"",
"name": "Too many wireless clients"
},
{
"rule": "%syslog.timestamp > = %macros.past_5m && %syslog.msg ~ \"@authentication failure@\"",
"name": "Syslog, Authentication failure on Device"
},
{
"rule": "%services.service_status = \"1\"",
"name": "Service warning"
},
{
"rule": "%services.service_status = \"2\"",
"name": "Service critical"
},
{
"rule": "%syslog.timestamp >= %macros.past_5m && %syslog.priority ~ \"alert\"",
"name": "Syslog, received Alert Priority Message"
},
{
"rule": "%syslog.timestamp >= %macros.past_5m && %syslog.priority ~ \"emergency\"",
"name": "Syslog, received Emergency Priority Message"
},
{
"rule": "%syslog.timestamp = %macros.past_5m && %syslog.msg ~ \"@arp table is full@\"",
"name": "Syslog, ARP table is full check on device "
},
{
"rule": "%sensors.sensor_type = \"upsAdvBatteryReplaceIndicator\" && %sensors.sensor_current = \"2\"",
"name": "APC UPS Battery Needs Replacement"
},
{
"rule": "%sensors.sensor_current = \"3\" && %sensors.sensor_type = \"upsBasicOutputStatus\"",
"name": "APC UPS Switched to Battery Power"
},
{
"rule": "%sensors.sensor_current = \"10\" && %sensors.sensor_type = \"upsBasicOutputStatus\"",
"name": "APC UPS in Hardware Failure Bypass Mode"
},
{
"rule": "%sensors.sensor_current = \"16\" && %sensors.sensor_type = \"upsBasicOutputStatus\"",
"name": "APC UPS in Emergency Static Bypass Mode"
},
{
"rule": "%sensors.sensor_current = \"12\" && %sensors.sensor_type = \"upsBasicOutputStatus\"",
"name": "APC UPS in Smart Trim Mode"
},
{
"rule": "%sensors.sensor_oid ~ \".1.3.6.1.4.1.11.2.14.11.1.2.6.1.4.[2-5]\" && %sensors.sensor_current = \"2\"",
"name": "HP Procurve Bad Power Supply"
},
{
"rule": "%sensors.sensor_oid = \".1.3.6.1.4.1.11.2.14.11.1.2.6.1.4.1\" && %sensors.sensor_current = \"2\"",
"name": "HP Procurve Fan Fault"
},
{
"rule": "%sensors.sensor_current > %sensors.sensor_limit && %sensors.sensor_alert = \"1\" && %macros.device_up = \"1\" && %macros.sensor_port_link = \"1\"",
"name": "Sensor over limit with linked port"
},
{
"rule": "%sensors.sensor_current < %sensors.sensor_limit_low && %sensors.sensor_alert = \"1\" && %macros.device_up = \"1\" && %macros.sensor_port_link = \"1\"",
"name": "Sensor under limit with linked port"
},
{
"rule": "%sensors.sensor_current = \"4\" && %sensors.sensor_type = \"upsOutputSourceState\"",
"name": "UPS is running on the bypass"
},
{
"rule": "%sensors.sensor_current = \"5\" && %sensors.sensor_type = \"upsOutputSourceState\"",
"name": "UPS is running on the battery"
},
{
"rule": "%sensors.sensor_current = \"3\" && %sensors.sensor_type = \"upsBatteryStatusState\"",
"name": "UPS has a low battery"
},
{
"rule": "%sensors.sensor_current = \"4\" && %sensors.sensor_type = \"upsBatteryStatusState\"",
"name": "UPS has a depleted battery"
},
{
"rule": "%sensors.sensor_descr ~ \"Percentage load\" && %sensors.sensor_current >= \"90\" && %sensors.sensor_type = \"rfc1628\"",
"name": "UPS has a heavy load"
},
{
"rule": "%sensors.sensor_current ~ \"[3-4]\" && %sensors.sensor_oid = \".1.3.6.1.4.1.232.3.2.5.1.1.37.\"",
"name": "HPE iLo Server drive degraded/failure"
},
{
"rule": "%sensors.sensor_current ~ \"[3-4]\" && %sensors.sensor_oid = \".1.3.6.1.4.1.232.6.2.9.3.1.4.\"",
"name": "HPE iLo Server Power Supply degraded/failure"
},
{
"rule": "%sensors.sensor_current ~ \"[3-4]\" && %sensors.sensor_oid = \".1.3.6.1.4.1.232.6.2.6.7.1.9.\"",
"name": "HPE iLo Server Fan degraded/failure"
},
{
"rule": "%sensors.sensor_current ~ \"[3-4]\" && %sensors.sensor_oid = \".1.3.6.1.4.1.232.1.2.2.1.1.6.\"",
"name": "HPE iLo Server CPU degraded/failure"
},
{
"rule": "%sensors.sensor_current ~ \"[3-4]\" && %sensors.sensor_oid = \".1.3.6.1.4.1.232.6.2.14.13.1.20.\"",
"name": "HPE iLo Server Memory degraded/failure"
},
{
"rule": "%applications.app_type = \"os-updates\" && %applications.app_status >= \"10\"",
"name": "Applications OS-Updates, New Updates Available"
},
{
"rule": "%devices.os = \"hpblmos\" && %sensors.sensor_type = \"hpblmos_psustate\" && %sensors.sensor_current = \"[3-4]\"",
"name": "HPE BladeSystem has a bad power supply"
},
{
"rule": "%devices.os = \"hpblmos\" && %sensors.sensor_type = \"hpblmos_fanstate\" && %sensors.sensor_current = \"[3-4]\"",
"name": "HPE BladeSystem has a bad fan"
},
{
"rule": "%devices.os = \"axiscam\" && %sensors.sensor_type = \"tempSensorStatusState\" && %sensors.sensor_current = \"2\"",
"name": "AXIS camera has a failed temperature sensor"
},
{
"rule": "%devices.os = \"rittal-lcp\" && %sensors.sensor_type = \"cmcIIIUnitStatus\" && %sensors.sensor_current = \"2\"",
"name": "RITTAL LCP has a failed status"
},
{
"rule": "%devices.os = \"rittal-lcp\" && %sensors.sensor_type = \"cmcIIIUnitStatus\" && %sensors.sensor_current = \"3\"",
"name": "RITTAL LCP has an overloaded status"
},
{
"rule": "%devices.os = \"dsm\" && %sensors.sensor_type = \"systemStatusState\" && %sensors.sensor_current = \"2\"",
"name": "Synology NAS has a failed status"
},
{
"rule": "%devices.os = \"dsm\" && %sensors.sensor_type = \"powerStatusState\" && %sensors.sensor_current = \"2\"",
"name": "Synology NAS has a failed power status"
},
{
"rule": "%devices.os = \"dsm\" && %sensors.sensor_type = \"systemFanStatusState\" && %sensors.sensor_current = \"2\"",
"name": "Synology NAS has a failed fan status"
},
{
"rule": "%devices.os = \"dsm\" && %sensors.sensor_type = \"cpuFanStatusState\" && %sensors.sensor_current = \"2\"",
"name": "Synology NAS has a failed CPU fan status"
},
{
"rule": "%devices.os = \"dsm\" && %sensors.sensor_type = \"upgradeAvailableState\" && %sensors.sensor_current = \"1\"",
"name": "Synology NAS has a new upgrade available"
},
{
"rule": "%devices.os = \"dsm\" && %sensors.sensor_type = \"raidStatusState\" && %sensors.sensor_current = \"[11-12]\"",
"name": "Synology NAS has a bad RAID status"
},
{
"rule": "%devices.os = \"dsm\" && %sensors.sensor_type = \"diskStatusState\" && %sensors.sensor_current = \"[4-5]\"",
"name": "Synology NAS has a bad disk status"
},
{
"rule": "%devices.os = \"f5\" && %sensors.sensor_type = \"sysChassisPowerSupplyStatus\" && %sensors.sensor_current = \"0\"",
"name": "F5 appliance has a bad power supply"
},
{
"rule": "%devices.os = \"f5\" && %sensors.sensor_type = \"sysChassisFanStatus\" && %sensors.sensor_current = \"0\"",
"name": "F5 appliance has a bad fan"
},
{
"rule": "%devices.os = \"nxos\" && %sensors.sensor_type = \"cefcFanTrayOperStatus\" && %sensors.sensor_current = \"[3-4]\"",
"name": "Cisco NX-OS device has a bad fan"
},
{
"rule": "%devices.os = \"panos\" & %sensors.type = \"panSysHAState\" && %sensors.sensor_current = \"1\" && %sensors.sensor_prev = \"2\"",
"name": "Palo Alto Networks passive firewall changed to active"
}
]