librenms/tests/snmpsim/raisecom.snmprec
Tony Murray f2f169ae78
Modernize mempools (#12282)
* mempools to modern module
quick hacky hrstorage port

* port ucd-snmp-mib to Mempools

* Populate DB for ucd
Prep for yaml

* initial yaml attempt

* more complex conversions
fixes to YamlDiscovery, make leading $ optional and allow mib::oid format

* walk full tables and skip values
normalize percentages above 100

* handle precent only ones (specify total as 100)

* Move default polling out of YamlMempoolsDiscovery

* fixes

* Update test data hrstorage should be correct.

* perc_warn for hrstorage

* Host Resources, record buffer, cached, and shared

* Host Resources is always better, don't do both HR and UCD

* fix unix, include warning levels

* variable size

* consolidate skip_values

* define mempools schema

* number instead of integer

* more schema refactor

* one more skip_values reference

* throw error for invalid oid translation
aos6

* a*  and Cisco

* updated test data

* update almost all hrstorage data files

* b*

* c* with test data
use standard cache for hrStorage

* use cache for storage module too

* hand bsnmp properly

* bdcom

* exclude total oid from yaml so it is not polled
May add a way to ignore this behavior and poll it, but I don't know if that is needed.

* automatically handle percent only values

* ciscowlc

* only poll used or free if we have used, free, and total.

* fix skipping

* the dlinkoning
fix find value when value "name" is numeric

* support numeric oids

* dnos/ftos attempt

* I guess we can't filter on total > 0

* edgecos

* e*

* f WIP

* f*

* gwd (aka g*)

* h* + procurve

* i*

* j*

* m*

* support 0% used memory (however unlikely)

* n*

* CISCO-PROCESS-MIB memory, share cache with processors module

* ignore mempools with invalid total

* p*

* quanta

* r*
fix raisecom mibs terribly broken

* s-z

* style fixes

* Move VRP back to PHP and make it actually work

* fix zynos

* update schema

* Update Cisco processor data for description bug fixes

* fix comware processors

* comware mempools with memory size
default precision to 1

* sophos-xg updated data

* hrstorage use ram size for buffers, cache, and shared

* Show memory available instead of free in device overview

* UCD, use same rrd format, store available instead of free in the db.

* Calculate availability for HOST-RESOURCES-MIB

* Convert UCD to standard polling

* rename old rrd files

* initial graph work

* graph WIP

* Graph looking decent

* Graph looking decent for hr

* remove old ucd_graph code

* handle availability mempool
more graph cleanup

* color adjustments

* remove accidental free calculation

* Update test data and fix corner cases

* fis pfsense

* update schema

* add default value for mempool_class

* fix whitespace

* update schema

* update schema correctly

* one more time

* fortigate_1500d-sensors missing oids

* Update docs.

* fix indent

* add implements MempoolsDiscovery explicitly to OS

* remove ucd_memory graph references
remove unused device_memory graph

* remove unused functions

* set devices with mempools to rediscover to prevent/minimize gaps

* use a subquery

* add overview graph

* port health mempools table

* Update device mempool

* only show overview if multiple

* Don't override user set warn percentages in discovery

* fix missed usage

* fix style

* Safety check to not rename rrd files incorrectly if migration has not been run.

* Fix overview percent bar and represent available and used on the bar

* missed an item to convert to mempool_class

* percent on the wrong side
2020-11-23 15:35:35 -06:00

68 lines
2.9 KiB
Plaintext

1.3.6.1.2.1.1.1.0|4|ROAP Version ISCOM5508-EPSC_ROAP_2.61.3(a)_20161019.(Compiled Oct 19 2016, 19:12:24)
1.3.6.1.2.1.1.2.0|6|1.3.6.1.4.1.8886.18.4.10
1.3.6.1.2.1.1.3.0|67|320373910
1.3.6.1.2.1.1.4.0|4|<private>
1.3.6.1.2.1.1.5.0|4|<private>
1.3.6.1.2.1.1.6.0|4|<private>
1.3.6.1.4.1.8886.1.1.1.3.1.2.1.2.1|2|3
1.3.6.1.4.1.8886.1.1.1.3.1.2.1.2.2|2|5
1.3.6.1.4.1.8886.1.1.1.3.1.2.1.2.3|2|6
1.3.6.1.4.1.8886.1.1.1.3.1.2.1.2.4|2|6
1.3.6.1.4.1.8886.1.1.1.3.1.2.1.2.5|2|4
1.3.6.1.4.1.8886.1.1.3.2.1.0|2|805306368
1.3.6.1.4.1.8886.1.1.3.2.2.0|2|138543105
1.3.6.1.4.1.8886.1.1.4.2.1.0|2|33
1.3.6.1.4.1.8886.1.1.4.3.1.1.3.1|2|3266
1.3.6.1.4.1.8886.1.1.4.3.1.1.3.2|2|998
1.3.6.1.4.1.8886.1.1.4.3.1.1.3.3|2|984
1.3.6.1.4.1.8886.1.1.4.3.1.1.3.4|2|1107
1.3.6.1.4.1.8886.1.1.4.3.1.1.3.5|2|1510
1.3.6.1.4.1.8886.1.1.4.3.1.1.3.6|2|1750
1.3.6.1.4.1.8886.1.1.5.2.2.1.2.1|66|7440
1.3.6.1.4.1.8886.1.1.5.2.2.1.2.2|66|7620
1.3.6.1.4.1.8886.1.1.5.2.2.1.2.3|66|7800
1.3.6.1.4.1.8886.1.1.5.2.2.1.2.4|66|7920
1.3.6.1.4.1.8886.1.1.5.2.2.1.3.1|2|1
1.3.6.1.4.1.8886.1.1.5.2.2.1.3.2|2|1
1.3.6.1.4.1.8886.1.1.5.2.2.1.3.3|2|1
1.3.6.1.4.1.8886.1.1.5.2.2.1.3.4|2|1
1.3.6.1.4.1.8886.1.2.1.3.0|2|3
1.3.6.1.4.1.8886.1.18.2.2.1.1.2.2082471937.1|2|36000
1.3.6.1.4.1.8886.1.18.2.2.1.1.2.2082471937.3|2|-2840
1.3.6.1.4.1.8886.1.18.2.2.1.1.2.2082471937.4|2|-2335
1.3.6.1.4.1.8886.1.18.2.2.1.1.2.2082471938.1|2|31039
1.3.6.1.4.1.8886.1.18.2.2.1.1.2.2082471938.3|2|-3098
1.3.6.1.4.1.8886.1.18.2.2.1.1.2.2082471938.4|2|-40000
1.3.6.1.4.1.8886.1.18.2.2.1.1.2.2082476033.1|2|38117
1.3.6.1.4.1.8886.1.18.2.2.1.1.2.2082476033.3|2|-3027
1.3.6.1.4.1.8886.1.18.2.2.1.1.2.2082476033.4|2|-920
1.3.6.1.4.1.8886.1.18.2.2.1.1.2.2082476034.1|2|37617
1.3.6.1.4.1.8886.1.18.2.2.1.1.2.2082476034.3|2|-4012
1.3.6.1.4.1.8886.1.18.2.2.1.1.2.2082476034.4|2|-5606
1.3.6.1.4.1.8886.1.18.2.2.1.1.2.2082476036.1|2|35500
1.3.6.1.4.1.8886.1.18.2.2.1.1.2.2082476036.3|2|-3054
1.3.6.1.4.1.8886.1.18.2.2.1.1.2.2082476036.4|2|-4012
1.3.6.1.4.1.8886.1.18.2.2.1.1.2.2082476039.1|2|33070
1.3.6.1.4.1.8886.1.18.2.2.1.1.2.2082476039.3|2|-2915
1.3.6.1.4.1.8886.1.18.2.2.1.1.2.2082476039.4|2|-40000
1.3.6.1.4.1.8886.1.18.2.2.1.1.2.2082476080.1|2|34429
1.3.6.1.4.1.8886.1.18.2.2.1.1.2.2082476080.3|2|-3178
1.3.6.1.4.1.8886.1.18.2.2.1.1.2.2082476080.4|2|-3089
1.3.6.1.4.1.8886.1.18.2.2.1.1.2.2082476084.1|2|34546
1.3.6.1.4.1.8886.1.18.2.2.1.1.2.2082476084.3|2|-3080
1.3.6.1.4.1.8886.1.18.2.2.1.1.2.2082476084.4|2|-3555
1.3.6.1.4.1.8886.1.24.2.1.1.2.1|4|
1.3.6.1.4.1.8886.1.24.2.1.1.2.2|4|
1.3.6.1.4.1.8886.1.24.2.1.1.3.1|2|2
1.3.6.1.4.1.8886.1.24.2.1.1.3.2|2|2
1.3.6.1.4.1.8886.1.24.2.1.1.4.1|2|0
1.3.6.1.4.1.8886.1.24.2.1.1.4.2|2|0
1.3.6.1.4.1.8886.1.24.2.1.1.5.1|2|0
1.3.6.1.4.1.8886.1.24.2.1.1.5.2|2|0
1.3.6.1.4.1.8886.1.24.2.1.1.6.1|2|2
1.3.6.1.4.1.8886.1.24.2.1.1.6.2|2|2
1.3.6.1.4.1.8886.6.1.1.1.1.0|4|8.2.29_20180611
1.3.6.1.4.1.8886.6.1.1.1.2.0|4|RAX711-C-DC/D-02 version A.02
1.3.6.1.4.1.8886.6.1.1.1.14.0|4|123002030702S18B08S0001G
1.3.6.1.6.3.10.2.1.3.0|2|1548438243