librenms/mibs/exalt/ExaltComProducts

1741 lines
73 KiB
Plaintext

ExaltComProducts DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-IDENTITY, OBJECT-TYPE,
IpAddress, Integer32, Gauge32
FROM SNMPv2-SMI
exaltcommunications, EthMainStatusT, EthAuxStatusT, AuxNmsMode,
EthPortMode, Te1StatusT, Te1LboT, EnableStatusT,
Te1LineCodeT, Te1LoopBackModeT, AlarmLevelT,
Led4ColorT, VlanStatusT, VlanGroupT, ExaltEnableT, AcmModulationT,
FileTransferTypeT, FileTransferStartT, NtpClientEnableT, TimeZoneT
FROM ExaltComm
OBJECT-GROUP
FROM SNMPv2-CONF
DisplayString, TEXTUAL-CONVENTION
FROM SNMPv2-TC;
productsMIB MODULE-IDENTITY
LAST-UPDATED "201304291021Z"
ORGANIZATION "Exalt"
CONTACT-INFO "Exalt Wireless Inc.
250 E Hacienda Ave.,
Campbell, CA, 95008
USA"
DESCRIPTION "Exalt devices"
REVISION "201304291021Z"
DESCRIPTION "This is the Exalt Products mib. rev:1.01"
::= { exaltcommunications 1 }
PwType ::= TEXTUAL-CONVENTION
DISPLAY-HINT "255a"
STATUS current
DESCRIPTION "This is a PW field."
SYNTAX OCTET STRING (SIZE(8..16))
productsMIBNotifications OBJECT IDENTIFIER ::= { productsMIB 1 }
productsMIBObjects OBJECT IDENTIFIER ::= { productsMIB 2 }
radioInfo OBJECT-IDENTITY
STATUS current
DESCRIPTION "Common Radio Information to all Exalt devices."
::= { productsMIBObjects 1 }
modelName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..20))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A descriptive name for the Radio. See Web, Radio Information, Model Name."
::= { radioInfo 1 }
partNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..20))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Part Number of the Radio. See Web, Radio Information, Part Number."
::= { radioInfo 2 }
serialNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..20))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Radio Serial Number. See Web, Radio Inforamtion, Serial Number."
::= { radioInfo 3 }
interfaceType OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..30))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Interfaces available on this radio. Ethernet, T1/E1, etc.
See Web, Radio Information, Interface Type."
::= { radioInfo 4 }
firmwareVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Radio Firmware Version. See Web, Radio Information, Firmware Version."
::= { radioInfo 5 }
bootVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Radio Boot Code Version. See Web, Radio Information, Boot Version."
::= { radioInfo 6 }
rdkDbVer OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Device RDK Database Version. See Web, Radio Information, RDK Database Version."
::= { radioInfo 11 }
txFreqRange OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Radio Tx Frequency Range.
FDD radios have a Tx and Rx frequency range.
See Web, Radio Information, RF Transmit range.
TDD radios have one frequency range.
See Web, Radio Information, RF Frequency Band."
::= { radioInfo 12 }
rxFreqRange OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Radio Rx Frequency Range.
FDD radios have a Tx and Rx frequency range.
See Web, Radio Information, RF Receive range.
TDD radios have one frequency range.
See Web, Radio Information, RF Frequency Band."
::= { radioInfo 13 }
rfFreqBand OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Device Frequency Band (Range).
TDD radios have N/A value in this field.
FDD radios have TX High or TX Low depending on used diplexer and Transmit frequency.
See Web, Radio Information, Tx Band."
::= { radioInfo 14 }
hwId OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Device Hardware ID number. See Web, Radio Information, Hardware ID number"
::= { radioInfo 15 }
modelNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Model Number of the Radio. See Web, Radio Information, Model Number"
::= { radioInfo 16 }
licenseFeatures OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The list of the features enabled by License Key"
::= { radioInfo 17 }
radioAdmin OBJECT-IDENTITY
STATUS current
DESCRIPTION "Radio Administration parameters."
::= { productsMIBObjects 2 }
sysDate OBJECT-TYPE
SYNTAX DisplayString (SIZE(10))
UNITS "MM/DD/YYYY"
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The Radio System Date, MM/DD/YYYY. See Web, Administration, Settings, Date.
To make permanent, write save to commitAdminSettings after change.
After commit, SNMP restarts and will be down for 30 seconds."
::= { radioAdmin 1 }
sysTime OBJECT-TYPE
SYNTAX DisplayString (SIZE(8))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The Radio System Time, HH:MM:SS, as 24 hours. See Web, Administration, Settings, Time.
To make permanent, write save to commitAdminSettings after change.
After commit, SNMP restarts and will be down for 30 seconds."
::= { radioAdmin 2 }
radioName OBJECT IDENTIFIER ::= { radioAdmin 3 }
rnLocal OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The user specifiable Radio Name for this radio.
See Web, Administration, Settings, Radio Name.
To make permanent, write save to commitAdminSettings after change."
::= { radioName 1 }
rnRemote OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Radio Name of the Radio at the far end of this RF Link.
Can only be set at that radio. See Web, Administration, Settings, Radio Name."
::= { radioName 2 }
linkName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The user specifiable Link Name for this radio.
See Web, Administration, Settings, Link Name.
To make permanent, write save to commitAdminSettings after change."
::= { radioAdmin 4 }
linkSecKey OBJECT-TYPE
SYNTAX DisplayString (SIZE(12))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The Link Security Key must match on both ends of an RF Link for traffic to pass.
See Web, Administration, Settings, Link Security Key.
To make permanent, write save to commitAdminSettings after change."
::= { radioAdmin 5 }
adminPassword OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The password for admin login to Web/CLI.
See Web, Administration, Settings, Admin Password.
To make permanent, write save to commitAdminSettings after change."
::= { radioAdmin 6 }
userPassword OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The password for user login to Web/CLI.
See Web, Administration, Settings, User Password.
To make permanent, write save to commitAdminSettings after change."
::= { radioAdmin 7 }
ipAddress OBJECT IDENTIFIER ::= { radioAdmin 8 }
ipLocal OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The IP address of local radio.
This IP address is used to manage radio.
See Web, Administration, Settings, IP Address.
To make permanent, write save to commitAdminSettings after change."
::= { ipAddress 1 }
ipRemote OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The IP address of the remote Radio.
This IP address is used to manage Remote radio.
Can only be set at that radio. See Web, Administration, Settings, IP Address."
::= { ipAddress 2 }
subnetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The Subnet Mask for IP address of local radio.
See Web, Administration, Settings, IP Mask.
To make permanent, write save to commitAdminSettings after change."
::= { radioAdmin 9 }
ipAddressNetmask OBJECT-TYPE
SYNTAX DisplayString (SIZE(9..18))
UNITS "IP/NN Where NN=00 To 32"
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The IP address and Subnet Mask of local radio. ie 10.0.0.1/24.
To make permanent, write save to commitAdminSettings after change."
::= { radioAdmin 10 }
defaultGateway OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The Default Gateway for local radio port.
See Web, Administration, Settings, Default Gateway.
To make permanent, write save to commitAdminSettings after change."
::= { radioAdmin 11 }
aesEnable OBJECT-TYPE
SYNTAX INTEGER {
aesDisable( 0 ),
aesEnable( 1 )
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The AES enable(0)/disable(1).
AES (Advance Encryption Standard) can be implemented to provide additional
data security for the wireless link.
This function requires an upgrade license key (purchased separately).
See Web, Administration, Settings, AES Settings, Enable AES.
To make permanent, write save to commitAdminSettings after change."
::= { radioAdmin 12 }
aesKey OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The symmetric AES key for encrypt/decrypt payload data.
Different bitlength encryption license keys (for example, 128-bit and 256-bit)
are available, depending on model type and license type.
AES Key should match both on local radio and far end radio.
See Web, Administration, Settings, AES Settings, AES Key.
To make permanent, write save to commitAdminSettings after change."
::= { radioAdmin 13 }
licKey OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The license key which defines radio features and capabilities.
See Web, Administration, Settings, License Key.
To make permanent, write save to commitAdminSettings after change."
::= { radioAdmin 14 }
-- rdkKey OBJECT-TYPE ::= { radioAdmin 15 }
-- domainName OBJECT-TYPE ::= { radioAdmin 16 }
snmpConfig OBJECT IDENTIFIER ::= { radioAdmin 17 }
trapIpaddr1 OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The IP address to which the SNMP traps are directed.
See Web, Administration, SNMP, Traps, Trap Destination IP Address."
::= { snmpConfig 1 }
trapIpaddrEnable1 OBJECT-TYPE
SYNTAX EnableStatusT
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Enable/Disable trap ip address."
::= { snmpConfig 2 }
trapIpaddr2 OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The IP address to which the SNMP traps are directed.
See Web, Administration, SNMP, Traps, Trap Destination IP Address."
::= { snmpConfig 3 }
trapIpaddrEnable2 OBJECT-TYPE
SYNTAX EnableStatusT
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Enable/Disable trap ip address."
::= { snmpConfig 4 }
trapIpaddr3 OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The IP address to which the SNMP traps are directed.
See Web, Administration, SNMP, Traps, Trap Destination IP Address."
::= { snmpConfig 5 }
trapIpaddrEnable3 OBJECT-TYPE
SYNTAX EnableStatusT
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Enable/Disable trap ip address."
::= { snmpConfig 6 }
trapIpaddr4 OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The IP address to which the SNMP traps are directed.
See Web, Administration, SNMP, Traps, Trap Destination IP Address."
::= { snmpConfig 7 }
trapIpaddrEnable4 OBJECT-TYPE
SYNTAX EnableStatusT
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Enable/Disable trap ip address."
::= { snmpConfig 8 }
trapAuth OBJECT-TYPE
SYNTAX EnableStatusT
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Authentication trap enable(1)/disable(0).
This is an SNMP standard trap when password information for SNMP is incorrect.
See Web, Administration, SNMP, Traps, Authentication Trap."
::= { snmpConfig 9 }
trapReboot OBJECT-TYPE
SYNTAX EnableStatusT
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Reboot trap enable(0)/disable(1).
This trap is sent after any radio reboot to inform the manager of the reboot status.
See Web, Administration, SNMP, Traps, Radio Reboot Trap."
::= { snmpConfig 10 }
trapLocLinkStat OBJECT-TYPE
SYNTAX EnableStatusT
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Local Link Status trap enable(0)/disable(1).
This trap is sent when Link is in errored state (equivalent to the Link LED).
See Web, Administration, SNMP, Traps, Local Link Status Trap."
::= { snmpConfig 11 }
trapLocAlarmStat OBJECT-TYPE
SYNTAX EnableStatusT
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Local Alarm Status trap enable(0)/disable(1).
This trap is sent when local radio Status is in errored state
(equivalent to the Status LED).
See Web, Administration, SNMP, Traps, Local Radio Status Trap."
::= { snmpConfig 12 }
trapRemAlarmStat OBJECT-TYPE
SYNTAX EnableStatusT
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Remote Alarm Status trap enable(0)/disable(1).
This trap is sent when remote radio Status is in errored state
(equivalent to the Status LED).
See Web, Administration, SNMP, Traps, Remote Radio Status Trap."
::= { snmpConfig 13 }
trapLocTempStat OBJECT-TYPE
SYNTAX EnableStatusT
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Local Temperature Status trap enable(0)/disable(1).
This trap is sent when the internal temperature reaches the warning point.
See Web, Administration, SNMP, Traps, Temperature Status Trap."
::= { snmpConfig 14 }
trapv1Enable OBJECT-TYPE
SYNTAX EnableStatusT
MAX-ACCESS read-write
STATUS current
DESCRIPTION "SNMPv1 Traps enable(0)/disable(1).
Enables traps for SNMP protocol version 1.
See Web, Administration, SNMP, Traps, Enable SNMPv1 Traps."
::= { snmpConfig 15 }
trapv2cEnable OBJECT-TYPE
SYNTAX EnableStatusT
MAX-ACCESS read-write
STATUS current
DESCRIPTION "SNMPv2c Traps enable(0)/disable(1).
Enables traps for SNMP protocol version 2c.
See Web, Administration, SNMP, Traps, Enable SNMPv2c Traps."
::= { snmpConfig 16 }
trapv3Enable OBJECT-TYPE
SYNTAX EnableStatusT
MAX-ACCESS read-write
STATUS current
DESCRIPTION "SNMPv3 Traps enable(0)/disable(1).
Enables traps for SNMP protocol version 3.
See Web, Administration, SNMP, Traps, Enable SNMPv3 Traps."
::= { snmpConfig 17 }
trapLocRslStat OBJECT-TYPE
SYNTAX EnableStatusT
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Local RSL Status trap enable(0)/disable(1).
This trap is sent when the local RSL drops below the value set in the
RSL Threshold Value (dBm) field.
See Web, Administration, SNMP, Traps, Local RSL Status Trap."
::= { snmpConfig 18 }
trapLocRslThreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Local RSL Threshold.
Exalt recommends that this trap be set to a value 5dBm or 10dBm above
the threshold as a warning that the system has faded and may be approaching an outage.
See Web, Administration, SNMP, Traps, Threshold Value."
::= { snmpConfig 19 }
commitSnmpSettings OBJECT-TYPE
SYNTAX DisplayString (SIZE(4..200))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Option strings to be written are: save, clear, correspondingly saving changes to
configuration to the persistent storage or clearing unsaved changes."
::= { snmpConfig 1000 }
ntp OBJECT-IDENTITY
STATUS current
DESCRIPTION "NTP and Time zone configuration."
::= { radioAdmin 18 }
ntpClientEnable OBJECT-TYPE
SYNTAX NtpClientEnableT
MAX-ACCESS read-write
STATUS current
DESCRIPTION "this mib to enable/disable the NTP client in the radio.
0 - disable NTP client.
1 - enable with 1 NTP server.
2 - enable with 2 NTP servers.
3 - enable with 3 NTP servers.
4 - enable with 4 NTP servers."
::= { ntp 1 }
ntpServer1IpAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE(7..15))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "IP address for the first NTP server in xxx.xxx.xxx.xxx format"
::= { ntp 2 }
ntpServer2IpAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE(7..15))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "IP address for the second NTP server in xxx.xxx.xxx.xxx format"
::= { ntp 3 }
ntpServer3IpAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE(7..15))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "IP address for the third NTP server in xxx.xxx.xxx.xxx format"
::= { ntp 4 }
ntpServer4IpAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE(7..15))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "IP address for the forth NTP server in xxx.xxx.xxx.xxx format"
::= { ntp 5 }
ntpTimeZoneSelect OBJECT-TYPE
SYNTAX TimeZoneT
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Time Zone selection.
0 - (GMT-11:00) Samoa
1 - (GMT-10.00) Hawaii
2 - (GMT-09:00) Alaska
3 - (GMT-08:00) Pacific Time
4 - (GMT-07:00) Arizona
5 - (GMT-07:00) Montain Time
6 - (GMT-06:00) Central Time
7 - (GMT-05:00) Eastern Time
8 - (GMT-05:00) Indiana (East)
9 - (GMT-04:00) Atlantic Time (Canada)
10- (GMT) Coordinated Universal Time
11- (GMT) London
12- (GMT+01:00) Berlin
13- (GMT+01:00) Belgrade
14- (GMT+01:00) Paris
15- (GMT+02:00) Cairo
16- (GMT+02:00) Helsinki
17- (GMT+03:00) Baghdad
18- (GMT+03:00) Moscow
19- (GMT+03:30) Tehran
20- (GMT+04:30) Kabul
21- (GMT+05:00) Karachi
22- (GMT+07:00) Bangkok
23- (GMT+08:00) Shanghai
24- (GMT+08:00) Taipei
25- (GMT+09:00) Tokyo
26- (GMT+09:00) Seoul
27- (GMT+10:00) Sydney
28- (GMT+10:00) Vladivostok"
::= { ntp 6 }
commitNtpSettings OBJECT-TYPE
SYNTAX DisplayString (SIZE(4..200))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This command allows saving or clear the NTP and Tome Zone configuration.
If the save includes the change of time zone, the radio will automatically reboot
to take effect the newly selected time zone.
Option strings to be written are: save, clear, correspondingly saving changes to
configuration to the persistent storage or clearing unsaved changes."
::= { ntp 1000 }
commitAdminSettings OBJECT-TYPE
SYNTAX DisplayString (SIZE(4..200))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The Commit Administration settings command. Valid values: 'save', 'clear'.
Configuration changes via SNMP do not take effect until
'save' (Commit) command is sent to this parameter.
'clear' (Cancel) command is used to cancel configuration changes before commit operation.
In case of invalid configuration this parameter contains text description of the problem."
::= { radioAdmin 1000 }
radioConfig OBJECT-IDENTITY
STATUS current
DESCRIPTION "The Radio Configuration Section."
::= { productsMIBObjects 3 }
systemConfig OBJECT-IDENTITY
STATUS current
DESCRIPTION "This is the device specific configuration section."
::= { radioConfig 1 }
commitSystemSettings OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The Commit System Configuration settings command. Valid values: 'save', 'clear'.
Configuration changes via SNMP do not take effect until
'save' (Commit) command is sent to this parameter.
'clear' (Cancel) command is used to cancel configuration changes before commit operation.
In case of invalid configuration this parameter contains text description of the problem."
::= { systemConfig 1000 }
interface OBJECT-IDENTITY
STATUS current
DESCRIPTION "Radio Interfaces Configuration section."
::= { radioConfig 2 }
te1 OBJECT-IDENTITY
STATUS current
DESCRIPTION "T1,E1 interfaces Configuration section.
Section allows to configure T1/E1 ports on the radio if any."
::= { interface 2 }
te1NumChannels OBJECT-TYPE
SYNTAX Gauge32
UNITS "channels"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Number of T1 or E1 channels supported by the Radio."
::= { te1 1 }
te1NumActiveChannels OBJECT-TYPE
SYNTAX Gauge32
UNITS "channels"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Current number of channels available, based
on bandwitdh of the RF link and the license key."
::= { te1 2 }
selectT1orE1 OBJECT-TYPE
SYNTAX INTEGER {
t1( 0 ),
e1( 1 )
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Select operation mode of T1/E1 interfaces. Either T1(0) or E1(1).
See Web, Configuration, Interface, T1/E1, Set To E1/T1 Mode button."
::= { te1 3 }
te1Interfaces OBJECT-TYPE
SYNTAX SEQUENCE OF Te1InterfacesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Attributes for T1 or E1 ports."
::= { te1 4 }
te1Interface OBJECT-TYPE
SYNTAX Te1InterfacesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in the T1/E1 Attribute table."
INDEX {
te1Status, t1LBO, te1AIS, t1LineCode, te1LoopBackMode
}
::= { te1Interfaces 1 }
Te1InterfacesEntry ::= SEQUENCE {
te1Status
Te1StatusT,
t1LBO
Te1LboT,
te1AIS
Te1StatusT,
t1LineCode
Te1LineCodeT,
te1LoopBackMode
Te1LoopBackModeT
}
te1Status OBJECT-TYPE
SYNTAX Te1StatusT
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The T1/E1 status: enable(1)/disable(0).
Parameter allows to enable/disable each individual T1 channel.
See Web, Configuration, Interface, T1/E1, Status.
To make permanent, write save to commitTe1Settings after change."
::= { te1Interface 1 }
t1LBO OBJECT-TYPE
SYNTAX Te1LboT
UNITS "feet"
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The Line Build Out length range.
Valid values (ft): lbo0to133(0), lbo133to266(1), lbo266to399(2), lbo399to533(3), lbo533to655(4).
See Web, Configuration, Interface, T1/E1, LBO.
To make permanent, write save to commitTe1Settings after change."
::= { te1Interface 2 }
te1AIS OBJECT-TYPE
SYNTAX Te1StatusT
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The T1/E1 AIS enabled flag: enable(1)/disable(0).
If enabled, the radio places an AIS code on the output of the associated interface
if and when the link fails or when there is no E1 signal available from the far
end to provide the user at the local end.
See Web, Configuration, Interface, T1/E1, AIS.
To make permanent, write save to commitTe1Settings after change."
::= { te1Interface 3 }
t1LineCode OBJECT-TYPE
SYNTAX Te1LineCodeT
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The T1/E1 Line Code type: b8zs(0), ami(1).
See Web, Configuration, Interface, T1/E1, AIS, Line Code.
To make permanent, write save to commitTe1Settings after change."
::= { te1Interface 4 }
te1LoopBackMode OBJECT-TYPE
SYNTAX Te1LoopBackModeT
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The Loop Back Mode for a T1/E1 interface.
Valid values: disabled(0), ExternalLocal(1), ExternalRemote(2), Internal(3).
All loopback configurations control the loop at the Line Interface integrated circuit,
which is the device wired directly to the front panel ports.
See Web, Configuration, Interface, T1/E1, AIS, Loopback.
To make permanent, write save to commitTe1Settings after change."
::= { te1Interface 5 }
commitTe1Settings OBJECT-TYPE
SYNTAX DisplayString (SIZE(4..200))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The Commit TE1 Configuration settings command. Valid values: 'save', 'clear'.
Configuration changes to TE1 ports via SNMP do not take effect until
'save' (Commit) command is sent to this parameter.
'clear' (Cancel) command is used to cancel configuration changes before commit operation.
In case of invalid configuration this parameter contains text description of the problem."
::= { te1 1000 }
fileManagement OBJECT-IDENTITY
STATUS current
DESCRIPTION "The File Management Section.
This section allows to initiate Upload/Download firmware/configuration/logs,
perform Firmware activation procedure."
::= { radioConfig 3 }
currentFwFilename OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..100))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The file name of the currently running firmware.
See Web, Administration, File Management, File Activation, Current File."
::= { fileManagement 1 }
alternateFwFilename OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..100))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The file name of the alternate firmware image.
See Web, Administration, File Management, File Activation, Alternative File."
::= { fileManagement 2 }
swapFWimage OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..200))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Swap the firmware images and restart radio.
To perform swap operation 'swap' command needs to be sent to this parameter.
For ExtendAirG2 to perform revert to factory operation 'factory' command needs to be sent.
Radio will become unavailable for several minutes."
::= { fileManagement 3 }
fileTransfer OBJECT-IDENTITY
STATUS current
DESCRIPTION "The File Transfer Section.
This section allows to initiate Upload/Download firmware/configuration/logs
over TFTP protocol."
::= { fileManagement 4 }
factoryFwFilename OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..100))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The file name of the factory firmware image.
See Web, Administration, File Management, File Activation, Factory File."
::= { fileManagement 5 }
tftpServerIp OBJECT-TYPE
SYNTAX DisplayString (SIZE(7..15))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The TFTP Server IP address.
"
::= { fileTransfer 1 }
uploadFilename OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..127))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The name of the file for upload operation.
For configuration file uploadFilename should be always 'config.xml'.
uploadFilename value should match the file name in TFTP server folder."
::= { fileTransfer 2 }
transferType OBJECT-TYPE
SYNTAX FileTransferTypeT
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The file transfer type.
Valid values:
- uploadFirmware(0)
- uploadConfig(1)
- uploadRDD(2) (Valid only for TDD radios)
- downloadFirmware(3)
- downloadConfig(4)
- downloadMIBs(5)
- downloadEventLogs(6).
The actual operation starts via updating transferStart parameter value."
::= { fileTransfer 3 }
transferStart OBJECT-TYPE
SYNTAX FileTransferStartT
MAX-ACCESS read-write
STATUS current
DESCRIPTION "TransferStart parameter is used to initiate file transfer operation.
Send startTransfer(1) to this parameter."
::= { fileTransfer 4 }
transferStatus OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..127))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current file transfer status."
::= { fileTransfer 5 }
radioMonitor OBJECT-IDENTITY
STATUS current
DESCRIPTION "Monitor Various components."
::= { productsMIBObjects 4 }
-- gps OBJECT IDENTIFIER ::= { radioMonitor 1 }
-- satelliteInView OBJECT-TYPE ::= { gps 1 }
alarms OBJECT IDENTIFIER ::= { radioMonitor 2 }
almLocal OBJECT IDENTIFIER ::= { alarms 3 }
locSysAlarms OBJECT IDENTIFIER ::= { almLocal 1 }
locEthAlarms OBJECT IDENTIFIER ::= { almLocal 2 }
locTe1Alarms OBJECT IDENTIFIER ::= { almLocal 3 }
-- gigEAlarms OBJECT IDENTIFIER ::= { locAlarms 4 }
-- locDS3Alarms OBJECT IDENTIFIER ::= { locAlarms 5 }
-- locV35Alarms OBJECT IDENTIFIER ::= { locAlarms 6 }
-- locOduAlarms OBJECT IDENTIFIER ::= { locAlarms 7 }
locLinkState OBJECT-TYPE
SYNTAX AlarmLevelT
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Link Status Alarm.
Possible values:
- almNORMAL(0) - Error-free connection (BER<10e-6)
- almMINOR(1) - Errorred connection (BER<10e-3)
- almMAJOR(2) - No link (BER>10e-3)
See Web, Monitor, Alarms, Link"
::= { locSysAlarms 1 }
locTempAlarm OBJECT-TYPE
SYNTAX AlarmLevelT
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Temperature Alarm state.
Possible values:
- almNORMAL(0) - Normal temprature range
- almMINOR(1) - Exceeding normal temprature range
See Web, Monitor, Alarms, Temperature"
::= { locSysAlarms 2 }
locCurrentTemp OBJECT-TYPE
SYNTAX Integer32
UNITS "C"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Internal Temperature in Celsius."
::= { locSysAlarms 3 }
locCurrentTempS OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Internal Temperature as a string. "
::= { locSysAlarms 4 }
-- locCollocAlarm OBJECT-TYPE ::= { locSysAlarms 8 }
-- remCollocAlarm OBJECT-TYPE ::= { remSysAlarms 8 }
locLinkSecMismatch OBJECT-TYPE
SYNTAX AlarmLevelT
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is link security mismatch alarm.
This alarm tells if the Link Security Key is matching or not.
Possible values:
- almNORMAL(0) - Link Secutiry keys match
- almMAJOR(2) - Link Secutiry keys do not match
"
::= { locSysAlarms 9 }
locLinkStateV OBJECT-TYPE
SYNTAX AlarmLevelT
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Vertical Link Status Alarm. -<g89><>"
::= { locSysAlarms 15 }
locLinkStateH OBJECT-TYPE
SYNTAX AlarmLevelT
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Horizontal Link Status Alarm. -<g89><>"
::= { locSysAlarms 16 }
-- T1/E1
locTe1LinkSummary OBJECT-TYPE
SYNTAX Led4ColorT
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The T1/E1 Link Summary LED color. "
::= { locTe1Alarms 1 }
locTE1Alarms OBJECT-TYPE
SYNTAX SEQUENCE OF Te1Alarms1Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The Local T1/E1 Interface Alarms."
::= { locTe1Alarms 2 }
locTe1AlarmsEntry OBJECT-TYPE
SYNTAX Te1Alarms1Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "T1/E1 Alarms table Entry."
INDEX {
locTe1Alarm
}
::= { locTE1Alarms 1 }
Te1Alarms1Entry ::= SEQUENCE {
locTe1Alarm
AlarmLevelT
}
locTe1Alarm OBJECT-TYPE
SYNTAX AlarmLevelT
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Alarms state for the Local T1/E1 Channel.
Possible values:
- almNORMAL(0) - Enabled and connection present
- almMAJOR(2) - Enabled and no connection present
- almDisable(3) - Disabled and no connection present
- almNotAvailable(4) - T1/E1 channel is not available
See Web, Monitor, Alarms, T1/E1 Input"
::= { locTe1AlarmsEntry 1 }
-- end of te1 local alarms
almRemote OBJECT IDENTIFIER ::= { alarms 4 }
remSysAlarms OBJECT IDENTIFIER ::= { almRemote 1 }
remEthAlarms OBJECT IDENTIFIER ::= { almRemote 2 }
remTe1Alarms OBJECT IDENTIFIER ::= { almRemote 3 }
remLinkState OBJECT-TYPE
SYNTAX AlarmLevelT
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Link Status Alarm for far end radio.
Possible values:
- almNORMAL(0) - Error-free connection (BER<10e-6)
- almMINOR(1) - Errorred connection (BER<10e-3)
- almMAJOR(2) - No link (BER>10e-3)
- almNotAvailable(4) - Telemetry is down
See Web, Monitor, Alarms, Link"
::= { remSysAlarms 1 }
remTempAlarm OBJECT-TYPE
SYNTAX AlarmLevelT
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Temperature Alarm state for far end radio.
Possible values:
- almNORMAL(0) - Normal temprature range
- almMINOR(1) - Exceeding normal temprature range
- almNotAvailable(4) - Telemetry is down
See Web, Monitor, Alarms, Temperature"
::= { remSysAlarms 2 }
remCurrentTemp OBJECT-TYPE
SYNTAX Integer32
UNITS "C"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Internal Temperature in Celsius for far end radio. "
::= { remSysAlarms 3 }
remCurrentTempS OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The internal Temperature as a string for far end radio. "
::= { remSysAlarms 4 }
-- remCollocAlarm OBJECT-TYPE ::= { remSysAlarms 8 }
remLinkSecMismatch OBJECT-TYPE
SYNTAX AlarmLevelT
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This is link security mismatch alarm.
This alarm tells if the Link Security Key is matching or not.
Possible values:
- almNORMAL(0) - Link Secutiry keys match
- almMAJOR(2) - Link Secutiry keys do not match
- almNotAvailable(4) - Telemetry is down
"
::= { remSysAlarms 9 }
remLinkStateV OBJECT-TYPE
SYNTAX AlarmLevelT
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Vertical Link Status Alarm. -<g89><>"
::= { remSysAlarms 15 }
remLinkStateH OBJECT-TYPE
SYNTAX AlarmLevelT
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Horizontal Link Status Alarm. -<g89><>"
::= { remSysAlarms 16 }
-- remote Te1 alarms
remTe1LinkSummary OBJECT-TYPE
SYNTAX Led4ColorT
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The T1/E1 Link Summary LED color. "
::= { remTe1Alarms 1 }
remTE1Alarms OBJECT-TYPE
SYNTAX SEQUENCE OF Te1AlarmsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The Remotel T1/E1 Interface Alarms."
::= { remTe1Alarms 2 }
remTe1AlarmsEntry OBJECT-TYPE
SYNTAX Te1AlarmsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "T1/E1 Alarms table Entry."
INDEX {
remTe1Alarm
}
::= { remTE1Alarms 1 }
Te1AlarmsEntry ::= SEQUENCE {
remTe1Alarm
AlarmLevelT
}
remTe1Alarm OBJECT-TYPE
SYNTAX AlarmLevelT
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Alarms state for the Local T1/E1 Channel of far end radio.
Possible values:
- almNORMAL(0) - Enabled and connection present
- almMAJOR(2) - Enabled and no connection present
- almDisable(3) - Disabled and no connection present
- almNotAvailable(4) - Telemetry is down or T1/E1 channel is not available
See Web, Monitor, Alarms, T1/E1 Input"
::= { remTe1AlarmsEntry 1 }
-- end remote Te1 alarms
performance OBJECT IDENTIFIER ::= { radioMonitor 3 }
perfLocal OBJECT IDENTIFIER ::= { performance 1 }
perfRemote OBJECT IDENTIFIER ::= { performance 2 }
locCurrentBER OBJECT-TYPE
SYNTAX Integer32
UNITS "BER * 1000000.0"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Curent Bit-Error Rate as scaled integer for local radio.
The BER multiplied by 1,000,000.
If the link is operating perfectly, this should indicate zero.
See Web, Monitor, Performance, Current BER"
::= { perfLocal 1 }
locCurrentBERstr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Current Bit-Error Rate as a string. "
::= { perfLocal 2 }
locCurrentRSL OBJECT-TYPE
SYNTAX Integer32
UNITS "dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current RSL is the measurement of the received signal level.
When the RSL falls below the threshold specification,
the link disconnects and will not reconnect until
the RSL is above the threshold specification.
See Web, Monitor, Performance, Current RSL"
::= { perfLocal 3 }
locCurrentRSLstr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Current RSL as a string."
::= { perfLocal 4 }
locErrorDuration OBJECT-TYPE
SYNTAX Integer32
UNITS "Seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Error Duration indicates the total number of seconds that occurred where
there was at least one bit error since the last time that
the radio statistics counter was reset.
See Web, Monitor, Performance, Errored Seconds"
::= { perfLocal 5 }
locErrorDurationStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Error Duration as a formatted string."
::= { perfLocal 6 }
locUnavailDuration OBJECT-TYPE
SYNTAX Integer32
UNITS "Seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Unavailable Duration keeps track of every second where the BER equals or exceeds 1x10-3,
as well as any seconds where there is a complete loss of radio communication.
See Web, Monitor, Performance, Unavailable Seconds"
::= { perfLocal 7 }
locUnavailDurationStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Unavailable Duration as a formatted string."
::= { perfLocal 8 }
locMinRSL OBJECT-TYPE
SYNTAX Integer32
UNITS "dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Minimum RSL indicates the worst (lowest) received signal level
that occurred since the last counter reset.
See Web, Monitor, Performance, Minimum RSL"
::= { perfLocal 9 }
locMinRSLstr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Minimum RSL value as a string."
::= { perfLocal 10 }
locMinRSLtimestamp OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Minimum RSL Timestamp indicates the date and time when the Minimum RSL occurred.
See Web, Monitor, Performance, Minimum RSL Timestamp"
::= { perfLocal 11 }
locMaxRSL OBJECT-TYPE
SYNTAX Integer32
UNITS "dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Maximum RSL indicates the best (highest) RSL
that occurred since the last counter reset.
See Web, Monitor, Performance, Maximum RSL"
::= { perfLocal 12 }
locMaxRSLstr OBJECT-TYPE
SYNTAX DisplayString
UNITS "dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Maximum RSL level As string."
::= { perfLocal 13 }
locSampleDuration OBJECT-TYPE
SYNTAX Integer32
UNITS "Seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Sample Duration indicates the amount of time passed since the last counter reset.
See Web, Monitor, Performance, Time Since Reset"
::= { perfLocal 14 }
locSampleDurationStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Sample Duration value as a formatted string."
::= { perfLocal 15 }
locEthPerfInterfaces OBJECT-TYPE
SYNTAX SEQUENCE OF LocEthPerfInterfacesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Performance characteristics of local Ethernet interfaces"
::= { perfLocal 16 }
locEthPerfInterfacesEntry OBJECT-TYPE
SYNTAX LocEthPerfInterfacesEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in the Performance characteristics of local Ethernet interfaces table"
INDEX {
locEthUtilizationIn,
locEthUtilizationOut,
locEthSpeed
}
::= { locEthPerfInterfaces 1 }
LocEthPerfInterfacesEntry ::= SEQUENCE {
locEthUtilizationIn Integer32,
locEthUtilizationOut Integer32,
locEthSpeed DisplayString
}
locEthUtilizationIn OBJECT-TYPE
SYNTAX Integer32 (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Inbound ethernet utilization (%).
See Web, Analysis, Ethernet Utilization."
::= { locEthPerfInterfacesEntry 1 }
locEthUtilizationOut OBJECT-TYPE
SYNTAX Integer32 (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Outbound ethernet utilization (%).
See Web, Analysis, Ethernet Utilization."
::= { locEthPerfInterfacesEntry 2 }
locEthSpeed OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current Ethernet Speed.
See Web, Monitor, Ethernet Performance."
::= { locEthPerfInterfacesEntry 3 }
locEthUtilizationWatermarkEnabled OBJECT-TYPE
SYNTAX ExaltEnableT
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Ethernet utilization watermark enable(1)/disable(0).
See Web, Analysis, Ethernet Utilization, Ethernet Utilization Watermark."
::= { perfLocal 17 }
locEthUtilizationWatermark OBJECT-TYPE
SYNTAX Integer32 (0..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Ethernet utilization watermark level (%).
See Web, Analysis, Ethernet Utilization, Watermark level."
::= { perfLocal 18 }
locEthUtilizationWatermarkTrapEnabled OBJECT-TYPE
SYNTAX ExaltEnableT
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Ethernet utilization watermark trap enable(1)/disable(0).
The watermark trap function allows administrators to receive an SNMP trap
when watermark conditions are exceeded.
See Web, Analysis, Ethernet Utilization, Enable Ethernet Utilization Trap."
::= { perfLocal 19 }
locEthUtilizationWatermarkTrapDuration OBJECT-TYPE
SYNTAX Integer32 (0..1440)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Ethernet utilization trap limit in minutes/day (0-1440 minutes).
See Web, Analysis, Ethernet Utilization, Send trap if watermark hit duration exceeds."
::= { perfLocal 20 }
locMaximumTxModulation OBJECT-TYPE
SYNTAX AcmModulationT
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The highest/maximum Tx modulation when ACM is enabled since the last counter reset.
See Web, Monitor, Performance, Tx modulation."
::= { perfLocal 100 }
locActiveTxModulation OBJECT-TYPE
SYNTAX AcmModulationT
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The active Tx modulation when ACM is enabled.
See Web, Monitor, Performance, Tx modulation."
::= { perfLocal 101 }
locMinimumTxModulation OBJECT-TYPE
SYNTAX AcmModulationT
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The lowest/minimum Tx modulation when ACM is enabled since the last counter reset.
See Web, Monitor, Performance, Tx modulation."
::= { perfLocal 102 }
locMaximumRxModulation OBJECT-TYPE
SYNTAX AcmModulationT
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The highest/maximum Rx modulation when ACM is enabled since the last counter reset.
See Web, Monitor, Performance, Rx modulation."
::= { perfLocal 103 }
locActiveRxModulation OBJECT-TYPE
SYNTAX AcmModulationT
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The active Rx modulation when ACM is enabled.
See Web, Monitor, Performance, Rx modulation."
::= { perfLocal 104 }
locMinimumRxModulation OBJECT-TYPE
SYNTAX AcmModulationT
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The lowest/minimum Rx modulation when ACM is enabled since the last counter reset.
See Web, Monitor, Performance, Rx modulation."
::= { perfLocal 105 }
--
-- ACM Tx/Rx Ethernet throughtput
--
locMaximumTxEthernetThroughput OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The highest/maximum Tx Ethernet throughput in Mbps when ACM is enabled
since the last counter reset.
See Web, Monitor, Performance, Tx Ethernet Throughput."
::= { perfLocal 106 }
locActiveTxEthernetThroughput OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The active Tx Ethernet throughput in Mbps when ACM is enabled.
See Web, Monitor, Performance, Tx Ethernet Throughput."
::= { perfLocal 107 }
locMinimumTxEthernetThroughput OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The lowest/minimum Tx Ethernet throughput in Mbps when ACM is enabled
since the last counter reset.
See Web, Monitor, Performance, Tx Ethernet Throughput."
::= { perfLocal 108 }
locMaximumRxEthernetThroughput OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The highest/maximum Rx Ethernet throughput in Mbps when ACM is enabled
since the last counter reset.
See Web, Monitor, Performance, Rx Ethernet Throughput."
::= { perfLocal 109 }
locActiveRxEthernetThroughput OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The active Rx Ethernet throughput in Mbps when ACM is enabled.
See Web, Monitor, Performance, Rx Ethernet Throughput."
::= { perfLocal 110 }
locMinimumRxEthernetThroughput OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The lowest/minimum Rx Ethernet throughput in Mbps when ACM is enabled
since the last counter reset.
See Web, Monitor, Performance, Rx Ethernet Throughput."
::= { perfLocal 111 }
locResetStats OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Write 'reset' to locResetStats to clear the Performance statistics."
::= { perfLocal 1000 }
remCurrentBER OBJECT-TYPE
SYNTAX Integer32
UNITS "BER * 1000000.0"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Curent Bit-Error Rate as scaled integer for far end radio.
The BER multiplied by 1,000,000.
If the link is operating perfectly, this should indicate zero.
See Web, Monitor, Performance, Current BER"
::= { perfRemote 1 }
remCurrentBERstr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Current Bit-Error Rate as a string. Far end radio"
::= { perfRemote 2 }
remCurrentRSL OBJECT-TYPE
SYNTAX Integer32
UNITS "dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current RSL is the measurement of the received signal level.
When the RSL falls below the threshold specification,
the link disconnects and will not reconnect until
the RSL is above the threshold specification.
See Web, Monitor, Performance, Current RSL"
::= { perfRemote 3 }
remCurrentRSLstr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Current RSL as a string."
::= { perfRemote 4 }
remErrorDuration OBJECT-TYPE
SYNTAX Integer32
UNITS "Seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Error Duration indicates the total number of seconds that occurred where
there was at least one bit error since the last time that
the radio statistics counter was reset.
See Web, Monitor, Performance, Errored Seconds, Remote column."
::= { perfRemote 5 }
remErrorDurationStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Error Duration as a formatted string. Far end radio."
::= { perfRemote 6 }
remUnavailDuration OBJECT-TYPE
SYNTAX Integer32
UNITS "Seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Unavailable Duration keeps track of every second where the BER equals or exceeds 1x10-3,
as well as any seconds where there is a complete loss of radio communication.
See Web, Monitor, Performance, Unavailable Seconds"
::= { perfRemote 7 }
remUnavailDurationStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Unavailable Duration as a formatted string. Far end radio."
::= { perfRemote 8 }
remMinRSL OBJECT-TYPE
SYNTAX Integer32
UNITS "dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Minimum RSL indicates the worst (lowest) received signal level
that occurred since the last counter reset.
See Web, Monitor, Performance, Minimum RSL, Remote column."
::= { perfRemote 9 }
remMinRSLstr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Minimum RSL value as a string. Far end radio."
::= { perfRemote 10 }
remMinRSLtimestamp OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Minimum RSL Timestamp indicates the date and time when the Minimum RSL occurred.
See Web, Monitor, Performance, Minimum RSL Timestamp, Remote column."
::= { perfRemote 11 }
remMaxRSL OBJECT-TYPE
SYNTAX Integer32
UNITS "dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Maximum RSL indicates the best (highest) RSL
that occurred since the last counter reset.
See Web, Monitor, Performance, Maximum RSL, Remote column."
::= { perfRemote 12 }
remMaxRSLstr OBJECT-TYPE
SYNTAX DisplayString
UNITS "dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Maximum RSL level As string. Far end radio."
::= { perfRemote 13 }
remSampleDuration OBJECT-TYPE
SYNTAX Integer32
UNITS "Seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Sample Duration indicates the amount of time passed since the last counter reset.
See Web, Monitor, Performance, Time Since Reset, Remote column."
::= { perfRemote 14 }
remSampleDurationStr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Sample Duration value as a formatted string. Far end radio."
::= { perfRemote 15 }
remResetStats OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Write 'reset' to remResetStats to clear the Performance statistics."
::= { perfRemote 1000 }
userThroughput OBJECT IDENTIFIER ::= { radioMonitor 5 }
aggregateUserThroughput OBJECT-TYPE
SYNTAX DisplayString
UNITS "MBit/s"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Aggregated User Throughput.
For FDD radios this parameter is always equal to fullDuplexEthernetThroughput."
::= { userThroughput 1 }
inboundEthernetThroughput OBJECT-TYPE
SYNTAX DisplayString
UNITS "MBit/s"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Inbound Ethernet Throughput.
For FDD radios this parameter is always N/A."
::= { userThroughput 2 }
outboundEthernetThroughput OBJECT-TYPE
SYNTAX DisplayString
UNITS "MBit/s"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Outbound Ethernet Throughput.
For FDD radios this parameter is always N/A."
::= { userThroughput 3 }
fullDuplexEthernetThroughput OBJECT-TYPE
SYNTAX DisplayString
UNITS "MBit/s"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Full Duplex Ethernet Throughput is determined by
the combination of settings for Mode and Bandwidth.
See Web, Monitor, User Throughput, Full Duplex Ethernet Throughput."
::= { userThroughput 4 }
radioReboot OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..100))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Reboot the radio device.
Send 'reboot' to radioReboot parameter to reboot the radio device."
::= { productsMIBObjects 1000 }
productsMIBConformance OBJECT IDENTIFIER ::= { productsMIB 3 }
productsMIBCompliances OBJECT IDENTIFIER ::= { productsMIBConformance 1 }
productsMIBGroups OBJECT IDENTIFIER ::= { productsMIBConformance 2 }
productsAllObjects OBJECT-GROUP
OBJECTS {
modelName,
partNumber,
serialNumber,
interfaceType,
firmwareVersion,
bootVersion,
rfFreqBand,
sysDate,
sysTime,
rnLocal,
rnRemote,
linkName,
linkSecKey,
adminPassword,
userPassword,
ipLocal,
ipRemote,
subnetMask,
ipAddressNetmask,
defaultGateway,
commitAdminSettings,
te1NumChannels,
te1NumActiveChannels,
selectT1orE1,
commitTe1Settings,
currentFwFilename,
alternateFwFilename,
swapFWimage,
locLinkState,
locLinkStateV,
locLinkStateH,
locTe1LinkSummary,
locTempAlarm,
locCurrentTemp,
locCurrentTempS,
locLinkSecMismatch,
remLinkState,
remLinkStateV,
remLinkStateH,
remTe1LinkSummary,
remTempAlarm,
remCurrentTemp,
remCurrentTempS,
remLinkSecMismatch,
locCurrentBER,
locCurrentBERstr,
locCurrentRSL,
locCurrentRSLstr,
locErrorDuration,
locErrorDurationStr,
locUnavailDuration,
locUnavailDurationStr,
locMinRSL,
locMinRSLstr,
locMinRSLtimestamp,
locMaxRSL,
locMaxRSLstr,
locSampleDuration,
locSampleDurationStr,
locResetStats,
remCurrentBER,
remCurrentBERstr,
remCurrentRSL,
remCurrentRSLstr,
remErrorDuration,
remErrorDurationStr,
remUnavailDuration,
remUnavailDurationStr,
remMinRSL,
remMinRSLstr,
remMinRSLtimestamp,
remMaxRSL,
remMaxRSLstr,
remSampleDuration,
remSampleDurationStr,
remResetStats,
radioReboot,
te1Status,
t1LBO,
te1AIS,
t1LineCode,
te1LoopBackMode,
locTe1Alarm,
remTe1Alarm,
aesEnable,
licKey,
aggregateUserThroughput,
inboundEthernetThroughput,
outboundEthernetThroughput,
fullDuplexEthernetThroughput,
locEthUtilizationIn,
locEthUtilizationOut,
locEthUtilizationWatermarkEnabled,
locEthUtilizationWatermark,
locEthUtilizationWatermarkTrapEnabled,
locEthUtilizationWatermarkTrapDuration
}
STATUS current
DESCRIPTION "This automatically created object group contains
all those objects that do not belong to any other
OBJECT-GROUP"
::= { productsMIBGroups 1 }
END