librenms/mibs/WANSTATS-MIB
2010-07-31 16:56:02 +00:00

6672 lines
249 KiB
Plaintext

WANSTATS-MIB DEFINITIONS ::= BEGIN
-- Agilent Technologies WAN and ATM statistics MIB
--
-- Copyright (C) 1997-1999 Agilent Technologies. All rights reserved.
-- Author: Agilent Technologies Netmetrix Division
-- Last updated: 18 November 1999
-- Purpose: Defines objects to collect ATM and WAN statistics for data
-- collection.
--
-- Change History:
-- 12/20/97 map Original version.
-- 01/21/98 map Integrate HLA 11 changes.
-- 01/23/98 map Bring up to HLA 11B level.
-- 01/28/98 map Bring up to HLA 11C level.
-- 02/10/98 map Formatting.
-- 05/19/99 map Modify definitions to conform to RFC 1406 and RFC 1407
-- 10/28/99 map Fix CLP1 in ATM AAL-5 Counters. Obsolete Hssi tables
-- 11/18/99 map Fix syntax errors
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE FROM SNMPv2-SMI
Counter64, TimeTicks, enterprises FROM SNMPv2-SMI
DisplayString, RowStatus FROM SNMPv2-TC
OwnerString FROM RMON-MIB;
hp OBJECT IDENTIFIER ::= {enterprises 11 }
nm OBJECT IDENTIFIER ::= { hp 2 }
system OBJECT IDENTIFIER ::= { nm 3 }
netElement OBJECT IDENTIFIER ::= { system 7 }
lanprobe OBJECT IDENTIFIER ::= { netElement 6 }
general OBJECT IDENTIFIER ::= { lanprobe 1 }
rmonExtension OBJECT IDENTIFIER ::= { general 5 }
statsExtension OBJECT IDENTIFIER ::= { rmonExtension 1 }
wanStatsMIB MODULE-IDENTITY
LAST-UPDATED "9911180000Z"
ORGANIZATION "Agilent Technologies NetMetrix Division"
CONTACT-INFO
"Agilent Technologies
NetMetrix Division
5070 Centennial Blvd
Colorado Springs, CO 80919"
DESCRIPTION
"The MIB containing RMON media statistics for WAN links."
::= { statsExtension 8 }
wanStatsMIBObjects OBJECT IDENTIFIER ::= { wanStatsMIB 1 }
wanSignalingStats OBJECT IDENTIFIER ::= { wanStatsMIBObjects 1 }
wanProtocolStats OBJECT IDENTIFIER ::= { wanStatsMIBObjects 2 }
wanPvcStats OBJECT IDENTIFIER ::= { wanStatsMIBObjects 3 }
wanHistoryMIBObjects OBJECT IDENTIFIER ::= { wanStatsMIB 2 }
wanSignalingHistory OBJECT IDENTIFIER ::= { wanHistoryMIBObjects 1 }
wanProtocolHistory OBJECT IDENTIFIER ::= { wanHistoryMIBObjects 2 }
wanPvcHistory OBJECT IDENTIFIER ::= { wanHistoryMIBObjects 3 }
wanT1E1StatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF WanT1E1StatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"T1/E1 signaling statistics."
::= { wanSignalingStats 1 }
wanT1E1StatsEntry OBJECT-TYPE
SYNTAX WanT1E1StatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Statistics for a T1/E1 interface. The near end of the link
refers to the side of the link that the probe is monitoring.
The far end is the side the probe is not on."
INDEX { wanT1E1StatsIndex }
::= { wanT1E1StatsTable 1 }
WanT1E1StatsEntry ::= SEQUENCE {
wanT1E1StatsIndex INTEGER (1..65535),
wanT1E1StatsDataSource OBJECT IDENTIFIER,
wanT1E1StatsDropEvents Counter64,
wanT1E1StatsInFrames Counter64,
wanT1E1StatsOutFrames Counter64,
wanT1E1StatsInOctets Counter64,
wanT1E1StatsOutOctets Counter64,
wanT1E1StatsESs Counter64,
wanT1E1StatsSESs Counter64,
wanT1E1StatsSEFSs Counter64,
wanT1E1StatsOOFs Counter64,
wanT1E1StatsUASs Counter64,
wanT1E1StatsCSSs Counter64,
wanT1E1StatsPCVs Counter64,
wanT1E1StatsLESs Counter64,
wanT1E1StatsBESs Counter64,
wanT1E1StatsDMs Counter64,
wanT1E1StatsLCVs Counter64,
wanT1E1StatsLOFs Counter64,
wanT1E1StatsLOSs Counter64,
wanT1E1StatsRAIs Counter64,
wanT1E1StatsAISs Counter64,
wanT1E1StatsTS16AISs Counter64,
wanT1E1StatsLOMFs Counter64,
wanT1E1StatsFarLOMFs Counter64,
wanT1E1StatsOwner OwnerString,
wanT1E1StatsStatus RowStatus
}
wanT1E1StatsIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of this object uniquely identifies this
wanT1E1StatsTable entry."
::= { wanT1E1StatsEntry 1 }
wanT1E1StatsDataSource OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object identifies the source of the data that this
wanT1E1StatsEntry analyzes. This source can be any DS1 or E1
interface on this device. In order to identify a particular
interface, this object shall identify the instance of the
ifIndex object, defined in MIB-II [RFC 1573] for the desired
interface. The ifType value associated with the ifIndex can
only be ds1(18)."
::= { wanT1E1StatsEntry 2 }
wanT1E1StatsDropEvents OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of events in which frames were dropped by
the probe due to lack of resources. Note that this number is
not necessarily the number of frames dropped; it is just the
number of times this condition has been detected."
::= { wanT1E1StatsEntry 3 }
wanT1E1StatsInFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames seen originating from the far end
of the link including errored frames."
::= { wanT1E1StatsEntry 4 }
wanT1E1StatsOutFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames seen originating from the near end
of the link including errored frames."
::= { wanT1E1StatsEntry 5 }
wanT1E1StatsInOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The sum of octets from all frames seen originating from the far
end of the link including errored frames."
::= { wanT1E1StatsEntry 6 }
wanT1E1StatsOutOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The sum of octets from all frames seen originating from the
near end of the link including errored frames."
::= { wanT1E1StatsEntry 7 }
wanT1E1StatsESs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"For ESF and E1-CRC links an Errored Second is a second
with one or more Path Code Violations OR one or more Out
of Frame defects OR one or more Controlled Slip events OR
a detected AIS defect.
For D4 and E1-noCRC links, the presence of Bipolar
Violations also triggers an Errored Second.
This is not incremented during an Unavailable Second."
::= { wanT1E1StatsEntry 8 }
wanT1E1StatsSESs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" A Severely Errored Second for ESF signals is a second
with 320 or more Path Code Violation Error Events OR one
or more Out of Frame defects OR a detected AIS defect.
For E1-CRC signals, a Severely Errored Second is a second
with 832 or more Path Code Violation error events OR one
or more Out of Frame defects.
For E1-noCRC signals, a Severely Errored Second is a 2048
LCVs or more.
For D4 signals, a Severely Errored Second is a count of
one-second intervals with Framing Error events, or an OOF
defect, or 1544 LCVs or more.
Controlled slips are not included in this parameter.
This is not incremented during an Unavailable Second."
::= { wanT1E1StatsEntry 9 }
wanT1E1StatsSEFSs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An Severely Errored Framing Second is a second with one
or more Out of Frame defects OR a detected AIS defect."
::= {wanT1E1StatsEntry 10 }
wanT1E1StatsOOFs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An OOF defect is the occurrence of a particular density
of Framing Error events.
For T1 links, an Out of Frame defect is declared when the
receiver detects two or more framing errors within a 3
msec period for ESF signals and 0.75 msec for D4 signals,
or two or more errors out of five or fewer consecutive
framing-bits.
For E1 links, an Out Of Frame defect is declared when
three consecutive frame alignment signals have been
received with an error (see G.706 Section 4.1 [17]).
Once an Out Of Frame Defect is declared, the framer
starts searching for a correct framing pattern. The Out
of Frame defect ends when the signal is in frame.
In-frame occurs when there are fewer than two frame bit
errors within 3 msec period for ESF signals and 0.75 msec
for D4 signals.
For E1 links, in-frame occurs when a) in frame N the
frame alignment signal is correct and b) in frame N+1 the
frame alignment signal is absent (i.e., bit 2 in TS0 is a
one) and c) in frame N+2 the frame alignment signal is
present and correct."
::= { wanT1E1StatsEntry 11 }
wanT1E1StatsUASs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unavailable Seconds (UAS) are calculated by counting the
number of seconds that the interface is unavailable. The
DS1 interface is said to be unavailable from the onset of
10 contiguous SESs, or the onset of the condition leading
to a failure (see Failure States). If the condition
leading to the failure was immediately preceded by one or
more contiguous SESs, then the DS1 interface
unavailability starts from the onset of these SESs. Once
unavailable, and if no failure is present, the DS1
interface becomes available at the onset of 10 contiguous
seconds with no SESs. Once unavailable, and if a failure
is present, the DS1 interface becomes available at the
onset of 10 contiguous seconds with no SESs, if the
failure clearing time is less than or equal to 10
seconds. If the failure clearing time is more than 10
seconds, the DS1 interface becomes available at the onset
of 10 contiguous seconds with no SESs, or the onset
period leading to the successful clearing condition,
whichever occurs later. With respect to the DS1 error
counts, all counters are incremented while the DS1
interface is deemed available. While the interface is
deemed unavailable, the only count that is incremented is
UASs."
::= { wanT1E1StatsEntry 12 }
wanT1E1StatsCSSs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A Controlled Slip Second is a one-second interval
containing one or more controlled slips."
::= { wanT1E1StatsEntry 13 }
wanT1E1StatsPCVs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A Path Coding Violation error event is a frame
synchronization bit error in the D4 and E1-noCRC formats,
or a CRC error in the ESF and E1-CRC formats."
::= { wanT1E1StatsEntry 14 }
wanT1E1StatsLESs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A Line Errored Second, according to T1M1.3, is a second
in which one or more Line Code Violation error events
were detected.
While many implementations are currently unable to detect
the zero strings, it is expected that interface
manufacturers will add this capability in deference to
ANSI; therefore, it will become available in time.
In the T1M1.3 specification, near end Line Code
Violations and far end Line Errored Seconds are counted.
For consistency, we count Line Errored Seconds at both
ends."
::= {wanT1E1StatsEntry 15 }
wanT1E1StatsBESs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A Bursty Errored Second (also known as Errored Second
type B) is a second with fewer than 320 and more than 1
Path Coding Violation error events, no Severely Errored
Frame defects and no detected incoming AIS defects.
Controlled slips are not included in this parameter.
This is not incremented during an Unavailable Second."
::= { wanT1E1StatsEntry 16 }
wanT1E1StatsDMs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A Degraded Minute is one in which the estimated error
rate exceeds 1E-6 but does not exceed 1E-3 (see G.821
[15]).
Degraded Minutes are determined by collecting all of the
Available Seconds, removing any Severely Errored Seconds
grouping the result in 60-second long groups and counting
a 60-second long group (a.k.a., minute) as degraded if the
cumulative errors during the seconds present in the group
exceed 1E-6. Available seconds are merely those seconds
which are not Unavailable as described below."
::= { wanT1E1StatsEntry 17 }
wanT1E1StatsLCVs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A Line Coding Violation (LCV) is the occurrence of either
a Bipolar Violation (BPV) or Excessive Zeroes (EXZ) Error
Event."
::= {wanT1E1StatsEntry 18 }
wanT1E1StatsLOFs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"For T1 links, the Loss Of Frame failure is declared when
an OOF or LOS defect has persisted for T seconds, where
2 <= T <= 10. The Loss Of Frame failure is cleared when
there have been no OOF or LOS defects during a period T
where 0 <= T <= 20. Many systems will perform 'hit
integration' within the period T before declaring or
clearing the failure e.g., see TR 62411 [16].
For E1 links, the Loss Of Frame Failure is declared when
an OOF defect is detected."
::= { wanT1E1StatsEntry 19 }
wanT1E1StatsLOSs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"For T1, the Loss Of Signal failure is declared upon
observing 175 +/- 75 contiguous pulse positions with no
pulses of either positive or negative polarity. The LOS
failure is cleared upon observing an average pulse
density of at least 12.5% over a period of 175 +/- 75
contiguous pulse positions starting with the receipt of a
pulse.
For E1 links, the Loss Of Signal failure is declared when
greater than 10 consecutive zeroes are detected (see
O.162 Section 3.4.4)."
::= { wanT1E1StatsEntry 20 }
wanT1E1StatsRAIs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Far End Alarm failure is also known as 'Yellow Alarm'
in the T1 case and 'Distant Alarm' in the E1 case.
For D4 links, the Far End Alarm failure is declared when
bit 6 of all channels has been zero for at least 335 ms
and is cleared when bit 6 of at least one channel is
non-zero for a period T, where T is usually less than one
second and always less than 5 seconds. The Far End Alarm
failure is not declared for D4 links when a Loss of
Signal is detected.
For ESF links, the Far End Alarm failure is declared if
the Yellow Alarm signal pattern occurs in at least seven
out of ten contiguous 16-bit pattern intervals and is
cleared if the Yellow Alarm signal pattern does not occur
in ten contiguous 16-bit signal pattern intervals.
For E1 links, the Far End Alarm failure is declared when
bit 3 of time-slot zero is received set to one on two
consecutive occasions. The Far End Alarm failure is
cleared when bit 3 of time-slot zero is received set to
zero."
::= { wanT1E1StatsEntry 21 }
wanT1E1StatsAISs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Alarm Indication Signal failure is declared when an
AIS defect is detected at the input and the AIS defect
still exists after the Loss Of Frame failure (which is
caused by the unframed nature of the 'all-ones' signal)
is declared. The AIS failure is cleared when the Loss Of
Frame failure is cleared."
::= { wanT1E1StatsEntry 22 }
wanT1E1StatsTS16AISs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"For E1 links, the TS16 Alarm Indication Signal failure is
declared when time-slot 16 is received as all ones for
all frames of two consecutive multiframes (see G.732
Section 4.2.6). This condition is never declared for T1."
::= { wanT1E1StatsEntry 23 }
wanT1E1StatsLOMFs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Loss Of MultiFrame failure is declared when two
consecutive multiframe alignment signals (bits 4 through
7 of TS16 of frame 0) have been received with an error.
The Loss Of Multiframe failure is cleared when the first
correct multiframe alignment signal is received. The
Loss Of Multiframe failure can only be declared for E1
links operating with G.732 [18] framing (sometimes called
'Channel Associated Signalling' mode)."
::= { wanT1E1StatsEntry 24 }
wanT1E1StatsFarLOMFs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Far End Loss Of Multiframe failure is declared when
bit 2 of TS16 of frame 0 is received set to one on two
consecutive occasions. The Far End Loss Of Multiframe
failure is cleared when bit 2 of TS16 of frame 0 is
received set to zero. The Far End Loss Of Multiframe
failure can only be declared for E1 links operating in
'Channel Associated Signalling' mode."
::= { wanT1E1StatsEntry 25 }
wanT1E1StatsOwner OBJECT-TYPE
SYNTAX OwnerString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The entity that configured this entry."
::= { wanT1E1StatsEntry 26 }
wanT1E1StatsStatus OBJECT-TYPE
SYNTAX RowStatus
-- MAX-ACCESS read-write
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this wanT1E1StatsTable entry."
::= { wanT1E1StatsEntry 27 }
wanT1E1HistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF WanT1E1HistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"T1/E1 signaling statistics."
::= { wanSignalingHistory 1 }
wanT1E1HistoryEntry OBJECT-TYPE
SYNTAX WanT1E1HistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Statistics for a particular T1/E1 interface. The near end of
the link refers to the side of the link that the probe is
monitoring. The far end is the side the probe is not on."
INDEX { wanT1E1HistoryIndex, wanT1E1HistorySampleIndex }
::= {wanT1E1HistoryTable 1 }
WanT1E1HistoryEntry ::= SEQUENCE {
wanT1E1HistoryIndex INTEGER (1..65535),
wanT1E1HistorySampleIndex INTEGER (1..2147483647),
wanT1E1HistoryIntervalStart TimeTicks,
wanT1E1HistoryDropEvents Counter64,
wanT1E1HistoryInFrames Counter64,
wanT1E1HistoryOutFrames Counter64,
wanT1E1HistoryInOctets Counter64,
wanT1E1HistoryOutOctets Counter64,
wanT1E1HistoryESs Counter64,
wanT1E1HistorySESs Counter64,
wanT1E1HistorySEFSs Counter64,
wanT1E1HistoryOOFs Counter64,
wanT1E1HistoryUASs Counter64,
wanT1E1HistoryCSSs Counter64,
wanT1E1HistoryPCVs Counter64,
wanT1E1HistoryLESs Counter64,
wanT1E1HistoryBESs Counter64,
wanT1E1HistoryDMs Counter64,
wanT1E1HistoryLCVs Counter64,
wanT1E1HistoryLOFs Counter64,
wanT1E1HistoryLOSs Counter64,
wanT1E1HistoryAISs Counter64,
wanT1E1HistoryRAIs Counter64,
wanT1E1HistoryTS16AISs Counter64,
wanT1E1HistoryLOMFs Counter64,
wanT1E1HistoryFarLOMFs Counter64,
wanT1E1HistoryInUtilization INTEGER (0..10000),
wanT1E1HistoryOutUtilization INTEGER (0..10000)
}
wanT1E1HistoryIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The history of which this entry is a port. The history
identified by a particular value of this index is the same
history as identified by the same value of historyControlIndex."
::= { wanT1E1HistoryEntry 1 }
wanT1E1HistorySampleIndex OBJECT-TYPE
-- SYNTAX OBJECT IDENTIFIER
SYNTAX INTEGER (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An index that uniquely identifies the particular sample this
entry represents among all samples associated with the same
historyControlEntry. This index starts at 1 and increases by
one as each new sample is taken."
::= {wanT1E1HistoryEntry 2 }
wanT1E1HistoryIntervalStart OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime at the start of the interval over which
this sample was measured. If the probe keeps track of time of
day, it should start the first sample of the history at a time
such that when the next hour of the day begins, a sample
is started at that instant. Note that following this rule may
require the probe to delay collection the first sample of the
history, as each sample must be of the same interval. Also
note that the sample which is currently being collected is not
accessible in this table until the end of its interval."
::= { wanT1E1HistoryEntry 3 }
wanT1E1HistoryDropEvents OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanT1E1StatsDropEvents during the
interval."
::= { wanT1E1HistoryEntry 4 }
wanT1E1HistoryInFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanT1E1StatsInFrames during the
interval."
::= { wanT1E1HistoryEntry 5 }
wanT1E1HistoryOutFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanT1E1StatsOutFrames during the
interval."
::= { wanT1E1HistoryEntry 6 }
wanT1E1HistoryInOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanT1E1StatsInOctets during the
interval."
::= { wanT1E1HistoryEntry 7 }
wanT1E1HistoryOutOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanT1E1StatsOutOctets during the
interval."
::= { wanT1E1HistoryEntry 8 }
wanT1E1HistoryESs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanT1E1StatsESs during the interval."
::= { wanT1E1HistoryEntry 9 }
wanT1E1HistorySESs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanT1E1StatsSESs during the interval."
::= { wanT1E1HistoryEntry 10 }
wanT1E1HistorySEFSs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanT1E1StatsSEFSs during the interval."
::= { wanT1E1HistoryEntry 11 }
wanT1E1HistoryOOFs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanT1E1StatsOOFs during the interval."
::= { wanT1E1HistoryEntry 12 }
wanT1E1HistoryUASs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanT1E1StatsUASs during the interval."
::= { wanT1E1HistoryEntry 13 }
wanT1E1HistoryCSSs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanT1E1StatsCSSs during the interval."
::= { wanT1E1HistoryEntry 14 }
wanT1E1HistoryPCVs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanT1E1StatsPCVs during the interval."
::= { wanT1E1HistoryEntry 15 }
wanT1E1HistoryLESs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanT1E1StatsLESs during the interval."
::= { wanT1E1HistoryEntry 16 }
wanT1E1HistoryBESs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanT1E1StatsBESs during the interval."
::= { wanT1E1HistoryEntry 17 }
wanT1E1HistoryDMs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanT1E1StatsDMs during the interval."
::= { wanT1E1HistoryEntry 18 }
wanT1E1HistoryLCVs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanT1E1StatsLCVs during the interval."
::= { wanT1E1HistoryEntry 19 }
wanT1E1HistoryLOFs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanT1E1StatsLOFSs during the interval."
::= { wanT1E1HistoryEntry 20 }
wanT1E1HistoryLOSs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanT1E1StatsLOSs during the interval."
::= { wanT1E1HistoryEntry 21 }
wanT1E1HistoryRAIs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanT1E1StatsRAIs during the interval."
::= { wanT1E1HistoryEntry 22 }
wanT1E1HistoryAISs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanT1E1StatsAISs during the interval."
::= { wanT1E1HistoryEntry 23 }
wanT1E1HistoryTS16AISs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanT1E1StatsTS16AISs during the interval."
::= { wanT1E1HistoryEntry 24 }
wanT1E1HistoryLOMFs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanT1E1StatsLOMFs during the interval."
::= { wanT1E1HistoryEntry 25 }
wanT1E1HistoryFarLOMFs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanT1E1StatsFarLOMFs during the interval."
::= { wanT1E1HistoryEntry 26 }
wanT1E1HistoryInUtilization OBJECT-TYPE
SYNTAX INTEGER (0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The best estimated of the mean physical layer network
utilization of traffic coming from the far end of the link in
hundreds of a percent."
::= { wanT1E1HistoryEntry 27 }
wanT1E1HistoryOutUtilization OBJECT-TYPE
SYNTAX INTEGER (0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The best estimated of the mean physical layer network
utilization of traffic coming from the near end of the link in
hundreds of a percent."
::= { wanT1E1HistoryEntry 28 }
wanVSeriesStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF WanVSeriesStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"V-series interface statistics."
::= { wanSignalingStats 2 }
wanVSeriesStatsEntry OBJECT-TYPE
SYNTAX WanVSeriesStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The statistics for a V-series interface. The near end of the
link refers to the side of the link that the probe is
monitoring. The far end is the side the probe is not on."
INDEX { wanVSeriesStatsIndex }
::= { wanVSeriesStatsTable 1 }
WanVSeriesStatsEntry ::= SEQUENCE {
wanVSeriesStatsIndex INTEGER (1..65535),
wanVSeriesStatsDataSource OBJECT IDENTIFIER,
wanVSeriesStatsDropEvents Counter64,
wanVSeriesStatsInFrames Counter64,
wanVSeriesStatsOutFrames Counter64,
wanVSeriesStatsInOctets Counter64,
wanVSeriesStatsOutOctets Counter64,
wanVSeriesStatsInFCSs Counter64,
wanVSeriesStatsOutFCSs Counter64,
wanVSeriesStatsInOverruns Counter64,
wanVSeriesStatsOutOverruns Counter64,
wanVSeriesStatsInterruptedFrames Counter64,
wanVSeriesStatsInAbortedFrames Counter64,
wanVSeriesStatsOutAbortedFrames Counter64,
wanVSeriesStatsOwner OwnerString,
wanVSeriesStatsStatus RowStatus
}
wanVSeriesStatsIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of this object uniquely identifies this
wanVSeriesStatsTable entry."
::= { wanVSeriesStatsEntry 1 }
wanVSeriesStatsDataSource OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object identifies the source of the data that this
wanVSeriesStatsEntry analyzes. This source can be and V-series
interface on this device. In order to identify a particular
interface, this object shall identify the instance of the
ifIndex object, defined in MIB-II [RFC 1573] for the desired
interface. The ifType value associated with the ifIndex can
only be rs232(33) , v35(45), v11(64), or v36(65)."
::= { wanVSeriesStatsEntry 2 }
wanVSeriesStatsDropEvents OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of events in which frames were dropped by the
probe due to lack of resources. Note that this number is not
necessarily the number of frames dropped; it is just the number
of times this condition has been detected."
::= { wanVSeriesStatsEntry 3 }
wanVSeriesStatsInFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames seen originating from the far end
of the link including errored."
::= { wanVSeriesStatsEntry 4 }
wanVSeriesStatsOutFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames seen originating from the near end
of the link including errored frames."
::= { wanVSeriesStatsEntry 5}
wanVSeriesStatsInOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The sum of octets from all frames seen originating from the
far end of the link including errored frames."
::= { wanVSeriesStatsEntry 6 }
wanVSeriesStatsOutOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The sum of octets from all frames seen originating from the
near end of the link including errored frames."
::= { wanVSeriesStatsEntry 7 }
wanVSeriesStatsInFCSs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of frames with an invalid frame check from the
far end of the link."
::= { wanVSeriesStatsEntry 8 }
wanVSeriesStatsOutFCSs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of frames with an invalid frame check from the
near end of the link."
::= { wanVSeriesStatsEntry 9 }
wanVSeriesStatsInOverruns OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of frames from the far end of the link that
failed to be received because the receiver did not accept the
data in time."
::= { wanVSeriesStatsEntry 10 }
wanVSeriesStatsOutOverruns OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of frames from the near end of the link that
failed to be received because the receiver did not accept the
data in time."
::= { wanVSeriesStatsEntry 11 }
wanVSeriesStatsInterruptedFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of frames that failed to be received or
transmitted on the port due to loss of modem signals."
::= { wanVSeriesStatsEntry 12 }
wanVSeriesStatsInAbortedFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of frames from the far end of the link aborted on the
port due to receiving an abort sequence."
::= { wanVSeriesStatsEntry 13 }
wanVSeriesStatsOutAbortedFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of frames from the near end of the link aborted on the
port due to receiving an abort sequence."
::= { wanVSeriesStatsEntry 14 }
wanVSeriesStatsOwner OBJECT-TYPE
SYNTAX OwnerString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The entity that configured this entry."
::= { wanVSeriesStatsEntry 15 }
wanVSeriesStatsStatus OBJECT-TYPE
SYNTAX RowStatus
-- MAX-ACCESS read-write
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this wanVSeriesStatsTable entry."
::= { wanVSeriesStatsEntry 16 }
wanVSeriesHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF WanVSeriesHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The history of which this entry is a port. The history
identified by a particular value of this index is the same
history as identified by the same value of historyControlIndex."
::= { wanSignalingHistory 2 }
wanVSeriesHistoryEntry OBJECT-TYPE
SYNTAX WanVSeriesHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The statistics for a V-series interface. The near end of the
link refers to the side of the link that the probe is
monitoring. The far end is the side the probe is not on."
INDEX { wanVSeriesHistoryIndex, wanVSeriesHistorySampleIndex }
::= { wanVSeriesHistoryTable 1 }
WanVSeriesHistoryEntry ::= SEQUENCE {
wanVSeriesHistoryIndex INTEGER (1..65535),
wanVSeriesHistorySampleIndex INTEGER (1..2147483647),
wanVSeriesHistoryIntervalStart TimeTicks,
wanVSeriesHistoryDropEvents Counter64,
wanVSeriesHistoryInFrames Counter64,
wanVSeriesHistoryOutFrames Counter64,
wanVSeriesHistoryInOctets Counter64,
wanVSeriesHistoryOutOctets Counter64,
wanVSeriesHistoryInFCSs Counter64,
wanVSeriesHistoryOutFCSs Counter64,
wanVSeriesHistoryInOverruns Counter64,
wanVSeriesHistoryOutOverruns Counter64,
wanVSeriesHistoryInterruptedFrames Counter64,
wanVSeriesHistoryInAbortedFrames Counter64,
wanVSeriesHistoryOutAbortedFrames Counter64,
wanVSeriesHistoryInUtilization INTEGER (0..10000),
wanVSeriesHistoryOutUtilization INTEGER (0..10000)
}
wanVSeriesHistoryIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The history of which this entry is a port. The history
identified by a particular value of this index is the same
history as identified by the same value of historyControlIndex."
::= { wanVSeriesHistoryEntry 1 }
wanVSeriesHistorySampleIndex OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An index that uniquely identifies the particular sample this
entry represents among all samples associated with the same
historyControlEntry. This index starts at 1 and increases by
one as each new sample is taken."
::= {wanVSeriesHistoryEntry 2 }
wanVSeriesHistoryIntervalStart OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime at the start of the interval over
which this sample was measured. If the probe keeps track of
time of day, it should start the first sample of the history at
a time such that when the next hour of the day begins, a sample
is started at that instant. Note that following this rule may
require the probe to delay collection the first sample of the
history, as each sample must be of the same interval. Also
note that the sample which is currently being collected is
not accessible in this table until the end of its interval."
::= { wanVSeriesHistoryEntry 3 }
wanVSeriesHistoryDropEvents OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanVSeriesStatsDropEvents during the
interval."
::= { wanVSeriesHistoryEntry 4 }
wanVSeriesHistoryInFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanVSeriesStatsInFrames during the
interval."
::= { wanVSeriesHistoryEntry 5 }
wanVSeriesHistoryOutFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanVSeriesStatsOutFrames during the
interval."
::= { wanVSeriesHistoryEntry 6 }
wanVSeriesHistoryInOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanVSeriesStatsInOctets during the
interval."
::= { wanVSeriesHistoryEntry 7 }
wanVSeriesHistoryOutOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanVSeriesStatsOutOctets during the
interval."
::= { wanVSeriesHistoryEntry 8 }
wanVSeriesHistoryInFCSs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanVSeriesStatsInFCSs during the
interval."
::= { wanVSeriesHistoryEntry 9 }
wanVSeriesHistoryOutFCSs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanVSeriesStatsOutFCSs during the
interval."
::= { wanVSeriesHistoryEntry 10 }
wanVSeriesHistoryInOverruns OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanVSeriesStatsInOverruns during the
interval."
::= { wanVSeriesHistoryEntry 11 }
wanVSeriesHistoryOutOverruns OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanVSeriesStatsOutOverruns during the
interval."
::= { wanVSeriesHistoryEntry 12 }
wanVSeriesHistoryInterruptedFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanVSeriesStatsInterruptedFrames
during the interval."
::= { wanVSeriesHistoryEntry 13 }
wanVSeriesHistoryInAbortedFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanVSeriesStatsInAbortedFrames
during the interval."
::= { wanVSeriesHistoryEntry 14 }
wanVSeriesHistoryOutAbortedFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanVSeriesStatsOutAbortedFrames
during the interval."
::= { wanVSeriesHistoryEntry 15 }
wanVSeriesHistoryInUtilization OBJECT-TYPE
SYNTAX INTEGER (0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The best estimated of the mean physical layer network
utilization of traffic coming from the far end of the link in
hundreds of a percent."
::= { wanVSeriesHistoryEntry 16 }
wanVSeriesHistoryOutUtilization OBJECT-TYPE
SYNTAX INTEGER (0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The best estimated of the mean physical layer network
utilization of traffic coming from the near end of the link in
hundreds of a percent."
::= { wanVSeriesHistoryEntry 17 }
wanHssiStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF WanHssiStatsEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"HSSI interface statistics."
::= { wanSignalingStats 3 }
wanHssiStatsEntry OBJECT-TYPE
SYNTAX WanHssiStatsEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"The statistics for a HSSI interface. The near end of the link
refers to the side of the link that the probe is monitoring.
The far end is the side the probe is not on."
INDEX { wanHssiStatsIndex }
::= { wanHssiStatsTable 1 }
WanHssiStatsEntry ::= SEQUENCE {
wanHssiStatsIndex INTEGER (1..65535),
wanHssiStatsDataSource OBJECT IDENTIFIER,
wanHssiStatsDropEvents Counter64,
wanHssiStatsInFrames Counter64,
wanHssiStatsOutFrames Counter64,
wanHssiStatsInOctets Counter64,
wanHssiStatsOutOctets Counter64,
wanHssiStatsRxLongFrames Counter64,
wanHssiStatsRxCrcErrors Counter64,
wanHssiStatsRxOverruns Counter64,
wanHssiStatsRxAborts Counter64,
wanHssiStatsTxAborts Counter64,
wanHssiStatsTxUnderruns Counter64,
wanHssiStatsRxRingErrors Counter64,
wanHssiStatsRxRingOverruns Counter64,
wanHssiStatsTxRingErrors Counter64,
wanHssiStatsPortOpErrors Counter64,
wanHssiStatsTxCmplProcessings Counter64,
wanHssiStatsOwner OwnerString,
wanHssiStatsStatus RowStatus
}
wanHssiStatsIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"The value of this object uniquely identifies this
wanHssiStatsTable entry."
::= { wanHssiStatsEntry 1 }
wanHssiStatsDataSource OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"This object identifies the source of the data that this
wanT1E1StatsEntry analyzes. This source can be any HSSI
interface on this device. In order to identify a particular
interface, this object shall identify the instance of the
ifIndex object, defined in MIB-II [RFC 1573] for the desired
interface. The ifType value associated with the ifIndex can
only be hssi(46)."
::= { wanHssiStatsEntry 2 }
wanHssiStatsDropEvents OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The total number of events in which frames were dropped by
the probe due to lack of resources. Note that this number is
not necessarily the number of frames dropped; it is just the
number of times this condition has been detected."
::= { wanHssiStatsEntry 3 }
wanHssiStatsInFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The total number of frames seen originating from the far end
of the link including errored frames."
::= { wanHssiStatsEntry 4 }
wanHssiStatsOutFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The total number of frames seen originating from the near end
of the link including errored frames."
::= { wanHssiStatsEntry 5 }
wanHssiStatsInOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The sum of octets from all frames seen originating from the
far end of the link including errored frames."
::= {wanHssiStatsEntry 6 }
wanHssiStatsOutOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The sum of octets from all frames seen originating from the
near end of the link including errored frames."
::= { wanHssiStatsEntry 7 }
wanHssiStatsRxLongFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Number of long frames from the far end of the link."
::= { wanHssiStatsEntry 8 }
wanHssiStatsRxCrcErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Number of frames from far end of link with CRC errors."
::= { wanHssiStatsEntry 9 }
wanHssiStatsRxOverruns OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Number of frames from far end of link with FIFO overrun errors."
::= { wanHssiStatsEntry 10 }
wanHssiStatsRxAborts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Number of frames from far end of link with abort status."
::= { wanHssiStatsEntry 11 }
wanHssiStatsTxAborts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Number of frames from near end of link with internal abort
errors."
::= { wanHssiStatsEntry 12 }
wanHssiStatsTxUnderruns OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Number of frames from near end of link aborted with underrun
errors."
::= { wanHssiStatsEntry 13 }
wanHssiStatsRxRingErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Number of receive ring error events."
::= { wanHssiStatsEntry 14 }
wanHssiStatsRxRingOverruns OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Number of receive ring overrun events."
::= { wanHssiStatsEntry 15 }
wanHssiStatsTxRingErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Number of transmit ring error events."
::= { wanHssiStatsEntry 16 }
wanHssiStatsPortOpErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Number of port operation error events."
::= { wanHssiStatsEntry 17 }
wanHssiStatsTxCmplProcessings OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Number of transmit complete processings (TINT)."
::= { wanHssiStatsEntry 18 }
wanHssiStatsOwner OBJECT-TYPE
SYNTAX OwnerString
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"The entity that configured this entry."
::= { wanHssiStatsEntry 19 }
wanHssiStatsStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"The status of this wanHssiStatsTable entry."
::= { wanHssiStatsEntry 20 }
wanHssiHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF WanHssiHistoryEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"HSSI interface statistics."
::= { wanSignalingHistory 3 }
wanHssiHistoryEntry OBJECT-TYPE
SYNTAX WanHssiHistoryEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"The statistics for a HSSI interface. The near end of the link
refers to the side of the link that the probe is monitoring.
The far end is the side the probe is not on."
INDEX { wanHssiHistoryIndex, wanHssiHistorySampleIndex }
::= { wanHssiHistoryTable 1 }
WanHssiHistoryEntry ::= SEQUENCE {
wanHssiHistoryIndex INTEGER (1..65535),
wanHssiHistorySampleIndex INTEGER (1..2147483647),
wanHssiHistoryIntervalStart TimeTicks,
wanHssiHistoryDropEvents Counter64,
wanHssiHistoryInFrames Counter64,
wanHssiHistoryOutFrames Counter64,
wanHssiHistoryInOctets Counter64,
wanHssiHistoryOutOctets Counter64,
wanHssiHistoryRxLongFrames Counter64,
wanHssiHistoryRxCrcErrors Counter64,
wanHssiHistoryRxOverruns Counter64,
wanHssiHistoryRxAborts Counter64,
wanHssiHistoryTxAborts Counter64,
wanHssiHistoryTxUnderruns Counter64,
wanHssiHistoryRxRingErrors Counter64,
wanHssiHistoryRxRingOverruns Counter64,
wanHssiHistoryTxRingErrors Counter64,
wanHssiHistoryPortOpErrors Counter64,
wanHssiHistoryTxCmplProcessings Counter64,
wanHssiHistoryInUtilization INTEGER (0..10000),
wanHssiHistoryOutUtilization INTEGER (0..10000)
}
wanHssiHistoryIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"The history of which this entry is a port. The history
identified by a particular value of this index is the same
history as identified by the same value of historyControlIndex."
::= { wanHssiHistoryEntry 1 }
wanHssiHistorySampleIndex OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"An index that uniquely identifies the particular sample this
entry represents among all samples associated with the same
historyControlEntry. This index starts at 1 and increases by
one as each new sample is taken."
::= { wanHssiHistoryEntry 2 }
wanHssiHistoryIntervalStart OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The value of sysUpTime at the start of the interval over
which this sample was measured. If the probe keeps track of
time of day, it should start the first sample of the history
at a time such that when the next hour of the day begins, a
sample is started at that instant. Note that following this
rule may require the probe to delay collection the first sample
of the history, as each sample must be of the same interval.
Also note that the sample which is currently being collected is
not accessible in this table until the end of its interval."
::= { wanHssiHistoryEntry 3 }
wanHssiHistoryDropEvents OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The change in value of wanHssiStatsDropEvents during the
interval."
::= { wanHssiHistoryEntry 4 }
wanHssiHistoryInFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The change in value of wanHssiStatsInFrames during the
interval."
::= { wanHssiHistoryEntry 5 }
wanHssiHistoryOutFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The change in value of wanHssiStatsOutFrames during the
interval."
::= { wanHssiHistoryEntry 6 }
wanHssiHistoryInOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The change in value of wanHssiStatsInOctets during the
interval."
::= { wanHssiHistoryEntry 7 }
wanHssiHistoryOutOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The change in value of wanHssiStatsOutOctets during the
interval."
::= { wanHssiHistoryEntry 8 }
wanHssiHistoryRxLongFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The change in value of wanHssiStatsRxLongFrames during the
interval."
::= { wanHssiHistoryEntry 9 }
wanHssiHistoryRxCrcErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The change in value of wanHssiStatsRxCrcErrors during the
interval."
::= { wanHssiHistoryEntry 10 }
wanHssiHistoryRxOverruns OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The change in value of wanHssiStatsRxOverruns during the
interval."
::= { wanHssiHistoryEntry 11}
wanHssiHistoryRxAborts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The change in value of wanHssiStatsRxAborts during the
interval."
::= { wanHssiHistoryEntry 12 }
wanHssiHistoryTxAborts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The change in value of wanHssiStatsTxAborts during the
interval."
::= { wanHssiHistoryEntry 13 }
wanHssiHistoryTxUnderruns OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The change in value of wanHssiStatsTxUnderruns during the
interval."
::= { wanHssiHistoryEntry 14 }
wanHssiHistoryRxRingErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The change in value of wanHssiStatsTxRingErrors during the
interval."
::= { wanHssiHistoryEntry 15 }
wanHssiHistoryRxRingOverruns OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The change in value of wanHssiStatsRxRingOverruns during the
interval."
::= { wanHssiHistoryEntry 16 }
wanHssiHistoryTxRingErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The change in value of wanHssiStatsTxRingErrors during the
interval."
::= { wanHssiHistoryEntry 17 }
wanHssiHistoryPortOpErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The change in value of wanHssiStatsPortOpErrors during the
interval."
::= { wanHssiHistoryEntry 18 }
wanHssiHistoryTxCmplProcessings OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The change in value of wanHssiStatsTxCmplProcessings during
the interval."
::= { wanHssiHistoryEntry 19 }
wanHssiHistoryInUtilization OBJECT-TYPE
SYNTAX INTEGER (0..10000)
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The best estimated of the mean physical layer network
utilization of traffic coming from the far end of the link in
hundreds of a percent."
::= { wanHssiHistoryEntry 20 }
wanHssiHistoryOutUtilization OBJECT-TYPE
SYNTAX INTEGER (0..10000)
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The best estimated of the mean physical layer network
utilization of traffic coming from the near end of the link in
hundreds of a percent."
::= { wanHssiHistoryEntry 21 }
wanT3E3StatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF WanT3E3StatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"T3/E3 signaling statistics"
::= { wanSignalingStats 4 }
wanT3E3StatsEntry OBJECT-TYPE
SYNTAX WanT3E3StatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Statistics for a T3/E3 interface. The near end of the link
refers to the side of the link that the probe is monitoring.
The far end is the side the probe is not on."
INDEX {wanT3E3StatsIndex }
::= { wanT3E3StatsTable 1 }
WanT3E3StatsEntry ::= SEQUENCE {
wanT3E3StatsIndex INTEGER (1..65535),
wanT3E3StatsDataSource OBJECT IDENTIFIER,
wanT3E3StatsDropEvents Counter64,
wanT3E3StatsInFrames Counter64,
wanT3E3StatsOutFrames Counter64,
wanT3E3StatsInOctets Counter64,
wanT3E3StatsOutOctets Counter64,
wanT3E3StatsPESs Counter64,
wanT3E3StatsPSESs Counter64,
wanT3E3StatsOOFs Counter64,
wanT3E3StatsSEFSs Counter64,
wanT3E3StatsUASs Counter64,
wanT3E3StatsLCVs Counter64,
wanT3E3StatsPCVs Counter64,
wanT3E3StatsLESs Counter64,
wanT3E3StatsCCVs Counter64,
wanT3E3StatsCESs Counter64,
wanT3E3StatsCSESs Counter64,
wanT3E3StatsRAIs Counter64,
wanT3E3StatsAISs Counter64,
wanT3E3StatsLOFs Counter64,
wanT3E3StatsLOSs Counter64,
wanT3E3StatsOwner OwnerString,
wanT3E3StatsStatus RowStatus
}
wanT3E3StatsIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of this object uniquely identifies this
wanT3E3StatsTable entry."
::= { wanT3E3StatsEntry 1 }
wanT3E3StatsDataSource OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object identifies the source of the data that this
wanT3E3StatsEntry analyzes. This source can be any DS3 or E3
interface on this device. In order to identify a particular
interface, this object shall identify the instance of the
ifIndex object, defined in MIB-II [RFC 1573] for the desired
interface. The ifType value of the associated ifIndex can
only be ds3(30)."
::= { wanT3E3StatsEntry 2 }
wanT3E3StatsDropEvents OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of events in which frames were dropped by
the probe due to lack of resources. Note that this number is
not necessarily the number of frames dropped; it is just the
number of times this condition has been detected."
::= { wanT3E3StatsEntry 3 }
wanT3E3StatsInFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames seen originating from the far end
of the link including errored frames."
::= { wanT3E3StatsEntry 4 }
wanT3E3StatsOutFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames seen originating from the near end
of the link including errored frames."
::= { wanT3E3StatsEntry 5 }
wanT3E3StatsInOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The sum of octets from all frames seen originating from the
far end of the link including errored frames."
::= { wanT3E3StatsEntry 6 }
wanT3E3StatsOutOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The sum of octets from all frames seen originating from the
near end of the link including errored frames."
::= { wanT3E3StatsEntry 7 }
wanT3E3StatsPESs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A PES is a second with one or more PCVs OR
one or more Out of Frame defects OR a detected incoming AIS.
This gauge is not incremented when UASs are counted."
::= { wanT3E3StatsEntry 8 }
wanT3E3StatsPSESs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A PSES is a second with 44 or more PCVs OR
one or more Out of Frame defects OR a detected incoming AIS.
This gauge is not incremented when UASs are counted."
::= { wanT3E3StatsEntry 9 }
wanT3E3StatsOOFs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A DS3 OOF defect is detected when any three or more errors
in sixteen or fewer consecutive F-bits occur within a DS3
M-frame. An OOF defect may also be called a Severely
Errored Frame (SEF) defect. An OOF defect is cleared when
reframe occurs. A DS3 Loss of Frame (LOF) failure is
declared when the DS3 OOF defect is consistent for 2 to 10
seconds. The DS3 OOF defect ends when reframe occurs.
The DS3 LOF failure is cleared when the DS3 OOF
defect is absent for 10 to 20 seconds.
An E3 OOF defect is detected when four consecutive frame
alignment signals have been incorrectly received in there
predicted positions in an E3 signal. E3 frame alignment
occurs when the presence of three consecutive frame
alignment signals have been detected."
::= { wanT3E3StatsEntry 10 }
wanT3E3StatsSEFSs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A SEFS is a second with one or more Out of Frame defects
OR a detected incoming AIS."
::= { wanT3E3StatsEntry 11 }
wanT3E3StatsUASs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"UAS are calculated by counting the number of seconds that
the interface is unavailable. The DS3 interface is said
to be unavailable from the onset of 10 contiguous PSESs, or
the onset of the condition leading to a failure (see Failure
States). If the condition leading to the failure was
immediately preceded by one or more contiguous PSESs, then
the DS3 interface unavailability starts from the onset of
these PSESs. Once unavailable, and if no failure is
present, the DS3 interface becomes available at the onset
of 10 contiguous seconds with no PSESs. Once unavailable,
and if a failure is present, the DS3 interface becomes
available at the onset of 10 contiguous seconds with no
PSESs, if the failure clearing time is less than
or equal to 10 seconds. If the failure clearing time is
more than 10 seconds, the DS3 interface becomes available
at the onset of 10 contiguous seconds with no PSESs, or
the onset period leading to the successful clearing
condition, whichever occurs later. With respect to the
DS3 error counts, all counters are incremented
while the DS3 interface is deemed available. While the
interface is deemed unavailable, the only count that is
incremented is UASs."
::= { wanT3E3StatsEntry 12 }
wanT3E3StatsLCVs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter is a count of both BPVs and EXZs
occurring over the accumulation period. An EXZ
increments the LCV by one regardless of the length
of the zero string."
::= { wanT3E3StatsEntry 13 }
wanT3E3StatsPCVs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"For all DS3 applications, a coding violation error event is
a P-bit Parity Error event. A P-bit Parity Error event is
the occurrence of a received P-bit code on the DS3 M-frame
that is not identical to the corresponding locally-
calculated code."
::= { wanT3E3StatsEntry 14 }
wanT3E3StatsLESs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A Line Errored Second is a second in
which one or more CVs occurred OR one or more LOS defects."
::= { wanT3E3StatsEntry 15 }
wanT3E3StatsCCVs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"For C-bit Parity and SYNTRAN DS3 applications, this is
the count of coding violations reported via the C-bits.
For C-bit Parity, it is a count of CP-bit parity errors
occurring in the accumulation interval. For SYNTRAN, it
is a count of CRC-9 errors occurring in the accumulation
interval."
::= { wanT3E3StatsEntry 16 }
wanT3E3StatsCESs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An CES is a second with one or more CCVs OR
one or more Out of Frame defects OR a detected incoming AIS.
This count is only for the SYNTRAN and C-bit Parity DS3
applications. This gauge is not incremented when UASs are
counted."
::= { wanT3E3StatsEntry 17 }
wanT3E3StatsCSESs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A CSES is a second with 44 or more CCVs OR
one or more Out of Frame defects OR a detected incoming AIS.
This count is only for the SYNTRAN and C-bit Parity DS3
applications. This gauge is not incremented when UASs
are counted."
::= { wanT3E3StatsEntry 18 }
wanT3E3StatsRAIs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Remote Alarm Indication (RAI) failure, in SYNTRAN
applications, is declared after detecting
the Yellow Alarm Signal on the alarm channel. See ANSI
T1.107a-1990 [10]. The Remote Alarm Indication failure,
in C-bit Parity DS3 applications, is declared
as soon as the preqsence of either one or two alarm signals
are detected on then Far End Alarm Channel. See [10].
The Remote Alarm Indication failure may also be declared
after detecting the far-end SEF/AIS defect (aka yellow).
The Remote Alarm Indication failure is cleared as soon as
the presence of the any of the above alarms are removed.
Also, the incoming failure state is declared when a defect
persists for at least 2-10 seconds. The defects are
the following: Loss of Signal (LOS), an Out of Frame (OOF)
or an incoming Alarm Indication Signal (AIS).
The Failure State is cleared when the defect is absent
for less than or equal to 20 seconds."
::= { wanT3E3StatsEntry 19 }
wanT3E3StatsAISs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The DS3 AIS is framed with 'stuck stuffing.' This implies
that it has a valid M-subframe alignments bits, M-frame
alignment bits, and P bits. The information bits are set
to a 1010... sequence, starting with a one (1) after each
M-subframe alignment bit, M-frame alignment bit, X bit, P
bit, and C bit. The C bits are all set to zero giving
what is called 'stuck stuffing.' The X bits are set to
one. The DS3 AIS defect is declared after DS3 AIS is
present in contiguous M-frames for a time equal to or
greater than T, where 0.2 ms <= T <= 100 ms.
The DS3 AIS defect is terminated after AIS is absent in
contiguous M-frames for a time equal to or greater than T.
The E3 binary content of the AIS is nominally a continuous
stream of ones. AIS detection and the application of
consequent actions, should be completed within a time
limit of 1 ms."
::= { wanT3E3StatsEntry 20 }
wanT3E3StatsLOFs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A DS3 Loss of Frame (LOF) failure is declared when the DS3 OOF
defect is consistent for 2 to 10 seconds. The DS3 OOF defect
ends when reframe occurs. The DS3 LOF failure is cleared when
the DS3 OOF defect is absent for 10 to 20 seconds. (See T1.231
section 7.1.2.2.1)"
::= { wanT3E3StatsEntry 21 }
wanT3E3StatsLOSs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The DS3 LOS defect is declared upon observing 175 +/- 75
contiguous pulse positions with no pulses of either
positive or negative polarity.
The DS3 LOS defect is terminated upon observing an average
pulse density of at least 33% over a period of 175 +/- 75
contiguous pulse positions starting with the receipt of a
pulse."
::= { wanT3E3StatsEntry 22 }
wanT3E3StatsOwner OBJECT-TYPE
SYNTAX OwnerString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The entity that configured this entry."
::= { wanT3E3StatsEntry 23 }
wanT3E3StatsStatus OBJECT-TYPE
SYNTAX RowStatus
-- MAX-ACCESS read-write
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this wanT3E3StatsTable entry."
::= { wanT3E3StatsEntry 24 }
wanT3E3HistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF WanT3E3HistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"T3/E3 signaling statistics"
::= { wanSignalingHistory 4 }
wanT3E3HistoryEntry OBJECT-TYPE
SYNTAX WanT3E3HistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Statistics for a T3/E3 interface. The near end of the link
refers to the side of the link that the probe is monitoring.
The far end is the side the probe is not on."
INDEX {wanT3E3HistoryIndex, wanT3E3HistorySampleIndex }
::= { wanT3E3HistoryTable 1 }
WanT3E3HistoryEntry ::= SEQUENCE {
wanT3E3HistoryIndex INTEGER (1..65535),
wanT3E3HistorySampleIndex INTEGER (1..2147483647),
wanT3E3HistoryIntervalStart TimeTicks,
wanT3E3HistoryDropEvents Counter64,
wanT3E3HistoryInFrames Counter64,
wanT3E3HistoryOutFrames Counter64,
wanT3E3HistoryInOctets Counter64,
wanT3E3HistoryOutOctets Counter64,
wanT3E3HistoryPESs Counter64,
wanT3E3HistoryPSESs Counter64,
wanT3E3HistoryOOFs Counter64,
wanT3E3HistorySEFSs Counter64,
wanT3E3HistoryUASs Counter64,
wanT3E3HistoryLCVs Counter64,
wanT3E3HistoryPCVs Counter64,
wanT3E3HistoryLESs Counter64,
wanT3E3HistoryCCVs Counter64,
wanT3E3HistoryCESs Counter64,
wanT3E3HistoryCSESs Counter64,
wanT3E3HistoryRAIs Counter64,
wanT3E3HistoryAISs Counter64,
wanT3E3HistoryLOFs Counter64,
wanT3E3HistoryLOSs Counter64,
wanT3E3HistoryInUtilization INTEGER (0..10000),
wanT3E3HistoryOutUtilization INTEGER (0..10000)
}
wanT3E3HistoryIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The history of which this entry is a port. The history
identified by a particular value of this index is the same
history as identified by the same value of historyControlIndex."
::= { wanT3E3HistoryEntry 1 }
wanT3E3HistorySampleIndex OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An index that uniquely identifies the particular sample this
entry represents among all samples associated with the same
historyControlEntry. This index starts at 1 and increases by
one as each new sample is taken."
::= { wanT3E3HistoryEntry 2 }
wanT3E3HistoryIntervalStart OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime at the start of the interval over which
this sample was measured. If the probe keeps track of time of
day, it should start the first sample of the history at a time
such that when the next hour of the day begins, a sample is
started at that instant. Note that following this rule may
require the probe to delay collection the first sample of the
history, as each sample must be of the same interval. Also
note that the sample which is currently being collected is
not accessible in this table until the end of its interval."
::= { wanT3E3HistoryEntry 3 }
wanT3E3HistoryDropEvents OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanT3E3StatsDropEvents during the
interval."
::= { wanT3E3HistoryEntry 4 }
wanT3E3HistoryInFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanT3E3StatsInFrames during the
interval."
::= { wanT3E3HistoryEntry 5 }
wanT3E3HistoryOutFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanT3E3StatsOutFrames during the
interval."
::= { wanT3E3HistoryEntry 6 }
wanT3E3HistoryInOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanT3E3StatsInOctets during the
interval."
::= { wanT3E3HistoryEntry 7 }
wanT3E3HistoryOutOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanT3E3StatsOutOctets during the
interval."
::= { wanT3E3HistoryEntry 8 }
wanT3E3HistoryPESs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanT3E3StatsPESs during the interval."
::= { wanT3E3HistoryEntry 9 }
wanT3E3HistoryPSESs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanT3E3StatsPSESs during the interval."
::= { wanT3E3HistoryEntry 10 }
wanT3E3HistoryOOFs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanT3E3StatsOOFs during the interval."
::= { wanT3E3HistoryEntry 11 }
wanT3E3HistorySEFSs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanT3E3StatsSEFs during the interval."
::= { wanT3E3HistoryEntry 12 }
wanT3E3HistoryUASs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanT3E3StatsUASs during the interval."
::= { wanT3E3HistoryEntry 13 }
wanT3E3HistoryLCVs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanT3E3StatsLCVs during the interval."
::= { wanT3E3HistoryEntry 14 }
wanT3E3HistoryPCVs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanT3E3StatsPCVs during the interval."
::= { wanT3E3HistoryEntry 15 }
wanT3E3HistoryLESs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanT3E3StatsLESs during the interval."
::= { wanT3E3HistoryEntry 16 }
wanT3E3HistoryCCVs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanT3E3StatsCCVs during the interval."
::= { wanT3E3HistoryEntry 17 }
wanT3E3HistoryCESs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanT3E3StatsCESs during the interval."
::= { wanT3E3HistoryEntry 18 }
wanT3E3HistoryCSESs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanT3E3StatsCSESs during the interval."
::= { wanT3E3HistoryEntry 19 }
wanT3E3HistoryRAIs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanT3E3StatsRAIs during the interval."
::= { wanT3E3HistoryEntry 20 }
wanT3E3HistoryAISs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanT3E3StatsAISs during the interval."
::= { wanT3E3HistoryEntry 21 }
wanT3E3HistoryLOFs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanT3E3StatsLOFs during the interval."
::= { wanT3E3HistoryEntry 22 }
wanT3E3HistoryLOSs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanT3E3StatsLOSs during the interval."
::= { wanT3E3HistoryEntry 23 }
wanT3E3HistoryInUtilization OBJECT-TYPE
SYNTAX INTEGER (0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The best estimated of the mean physical layer network
utilization of traffic coming from the far end of the link
in hundreds of a percent."
::= { wanT3E3HistoryEntry 24 }
wanT3E3HistoryOutUtilization OBJECT-TYPE
SYNTAX INTEGER (0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The best estimated of the mean physical layer network
utilization of traffic coming from the near end of the link
in hundreds of a percent."
::= { wanT3E3HistoryEntry 25 }
wanAtmStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF WanAtmStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ATM signaling statistics."
::= { wanSignalingStats 5 }
wanAtmStatsEntry OBJECT-TYPE
SYNTAX WanAtmStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The statistics for an ATM interface. The near end of the link
refers to the side of the link that the probe is monitoring.
The far end is the side the probe is not on. In an ATM network,
there are many far ends of the link, but they shall be logically
grouped into one end in this table."
INDEX { wanAtmStatsIndex }
::= { wanAtmStatsTable 1 }
WanAtmStatsEntry ::= SEQUENCE {
wanAtmStatsIndex INTEGER (1..65535),
wanAtmStatsDataSource OBJECT IDENTIFIER,
wanAtmStatsDropEvents Counter64,
wanAtmStatsInCells Counter64,
wanAtmStatsOutCells Counter64,
wanAtmStatsInCLP1 Counter64,
wanAtmStatsOutCLP1 Counter64,
wanAtmStatsConnectionEvents Counter64,
wanAtmStatsErroredPDUs Counter64,
wanAtmStatsSetupAttempts Counter64,
wanAtmStatsInRoutesUnavailable Counter64,
wanAtmStatsOutRoutesUnavailable Counter64,
wanAtmStatsInResourcesUnavailable Counter64,
wanAtmStatsOutResourcesUnavailable Counter64,
wanAtmStatsInUnsuccessfulCalls Counter64,
wanAtmStatsOutUnsuccessfulCalls Counter64,
wanAtmStatsInIncorrectMsgs Counter64,
wanAtmStatsOutIncorrectMsgs Counter64,
wanAtmStatsInPartyEvents Counter64,
wanAtmStatsOutPartyEvents Counter64,
wanAtmStatsInExpiries Counter64,
wanAtmStatsOutExpiries Counter64,
wanAtmStatsInRestartErrors Counter64,
wanAtmStatsOutRestartErrors Counter64,
wanAtmStatsInSVCs Counter64,
wanAtmStatsOutSVCs Counter64,
wanAtmStatsInOCDs Counter64,
wanAtmStatsOutOCDs Counter64,
wanAtmStatsInLOCs Counter64,
wanAtmStatsOutLOCs Counter64,
wanAtmStatsInLOFs Counter64,
wanAtmStatsOutLOFs Counter64,
wanAtmStatsInLOPs Counter64,
wanAtmStatsOutLOPs Counter64,
wanAtmStatsInLOSs Counter64,
wanAtmStatsOutLOSs Counter64,
wanAtmStatsOwner OwnerString,
wanAtmStatsStatus RowStatus
}
wanAtmStatsIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of this object uniquely identifies this wanAtmStatsTable entry."
::= { wanAtmStatsEntry 1 }
wanAtmStatsDataSource OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object identifies the source of the data that this
wanAtmStatsEntry analyzes. This source can be any interface on
this device. in order to identify a particular interface, this
object shall identify the instance of the ifIndex object, defined
in MIB-II [RFC 1573] for the desired interface. The ifType value
associated with the ifIndex can only be atm(37)."
::= { wanAtmStatsEntry 2 }
wanAtmStatsDropEvents OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of events in which frames were dropped by the
probe due to lack of resources. Note that this number is not
necessarily the number of frames dropped; it is just the number
of times this condition has been detected."
::= { wanAtmStatsEntry 3 }
wanAtmStatsInCells OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of cells seen coming from the far end of the
link including errored cells."
::= { wanAtmStatsEntry 4 }
wanAtmStatsOutCells OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of cells seen coming from the near end of the
link including errored cells."
::= { wanAtmStatsEntry 5 }
wanAtmStatsInCLP1 OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of cells with the CLP bit set seen coming from
the far end of the link."
::= { wanAtmStatsEntry 6 }
wanAtmStatsOutCLP1 OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of cells with the CLP bit set seen coming from
the near end of the link."
::= { wanAtmStatsEntry 7 }
wanAtmStatsConnectionEvents OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter counts the sum of the following errors:
1) SSCOP Connection Disconnect Counter
The abnormal occurrence of this event is characterized by the
expiry of Timer_NO_RESPONSE. (This event is
communicated to the layer management with MAA-ERROR
code P. See ITU-T Q.2110.)
2) SSCOP Connection Initiation Failure
This condition indicates the inability to establish an SSCOP
connection. This event occurs whenever the number of
expiries of the connection control timer (Timer_CC) exceeds
the MaxCC or upon receipt of a connection reject message
BGREJ PDU. (This event is communicated to layer
management with MAA-ERROR code O. See ITU-T
Q.2110.)
3) SSCOP Connection Re-Establ/Resynch
This event occurs upon receipt of a BGN PDU or RESYNC
PDU."
::= { wanAtmStatsEntry 8 }
wanAtmStatsErroredPDUs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter counts the sum of the following errors:
1) Invalid PDUs.
These are defined in SSCOP and consist of PDUs with
incorrect length (MAA-ERROR code U), undefined PDU type
code or not 32-bit aligned.
2) PDUs that result in MAA error codes and are discarded
See Errors A-M and Q-T defined in ITU-T Q.2110."
::= { wanAtmStatsEntry 9 }
wanAtmStatsSetupAttempts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter counts the number of call setup attempts (both
successful and unsuccessful) detected on this interface."
::= { wanAtmStatsEntry 10 }
wanAtmStatsInRoutesUnavailable OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is incremented when a RELEASE, RELEASE COMPLETE
(only when not preceded by a RELEASE mesg for the same call),
ADD PARTY REJECT, or STATUS message that contains one of the
following cause code values is received (Note: These cause
values apply to both UNI3.0 and UNI3.1):
Cause Value Meaning
1 unallocated (unassigned) number
2 no route to specified transit
network
3 no route to destination
88 incompatible destination
NOTE: For this counter, RELEASE COMPLETE messages that are
a reply to a previous RELEASE message and contain the same
cause value, are redundant (for counting purposes) and should
not be counted."
::= { wanAtmStatsEntry 11 }
wanAtmStatsOutRoutesUnavailable OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is incremented when a RELEASE, RELEASE COMPLETE
(only when not preceded by a RELEASE mesg for the same call),
ADD PARTY REJECT, or STATUS message that contains one of the
following cause code values is transmitted (Note: These cause
values apply to both UNI3.0 and UNI3.1):
Cause Value Meaning
1 unallocated (unassigned) number
2 no route to specified transit
network
3 no route to destination
NOTE: For this counter, RELEASE COMPLETE messages that are a
reply to a previous RELEASE message and contain the same cause
value, are redundant(for counting purposes) and should not be
counted."
::= { wanAtmStatsEntry 12 }
wanAtmStatsInResourcesUnavailable OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is incremented when a RELEASE, RELEASE COMPLETE
(only when not preceded by a RELEASE mesg for the same call),
ADD PARTY REJECT, or STATUS message that contains one of the
following cause code values is received (Note: These cause
values apply to both UNI3.0 and UNI3.1 unless otherwise
stated):
Cause Value Meaning
35 requested VPCI/VCI not available
37 user cell rate not available
(UNI3.1 only)
38 network out of order
41 temporary failure
45 no VPCI/VCI available
47 resource unavailable, unspecified
49 Quality of Service unavailable
51 user cell rate not available
(UNI3.0 only)
58 bearer capability not presently
available
63 Service or option not available,
unspecified
92 too many pending add party requests
NOTE: For this counter, RELEASE COMPLETE messages that are a
reply to a previous RELEASE message and contain the same cause
value, are redundant (for counting purposes) and should not be
counted."
::= { wanAtmStatsEntry 13 }
wanAtmStatsOutResourcesUnavailable OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is incremented when a RELEASE, RELEASE COMPLETE
(only when not preceded by a RELEASE mesg for the same call),
ADD PARTY REJECT, or STATUS message that contains one of the
following cause code values is transmitted (Note: These cause
values apply to both UNI3.0 and UNI3.1 unless otherwise stated):
Cause Value Meaning
35 requested VPCI/VCI not available
37 user cell rate not available
(UNI3.1 only)
38 network out of order
41 temporary failure
45 no VPCI/VCI available
47 resource unavailable, unspecified
49 Quality of Service unavailable
51 user cell rate not available
(UNI3.0 only)
58 bearer capability not presently
available
63 Service or option not available,
unspecified
92 too many pending add party requests
NOTE: For this counter, RELEASE COMPLETE messages that are a
reply to a previous RELEASE message and contain the same cause
value, are redundant (for counting purposes) and should not be
counted."
::= { wanAtmStatsEntry 14 }
wanAtmStatsInUnsuccessfulCalls OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is incremented when a RELEASE, RELEASE COMPLETE
(only when not preceded by a RELEASE mesg for the same call),
ADD PARTY REJECT, or STATUS message that contains one of the
following cause code values is received (Note: These cause
values apply to both UNI3.0 and UNI3.1):
Cause Value Meaning
17 user busy
18 no user responding
21 call rejected
22 number changed
23 user rejects all calls with
calling line id restriction
27 destination out of order
31 normal, unspecified
88 incompatible destination
NOTE: For this counter, RELEASE COMPLETE messages that are a
reply to a previous RELEASE message and contain the same cause
value, are redundant (for counting purposes) and should not be
counted.
Note: Cause Value #30 'response to STATUS ENQUIRY' was not
included in this memo since it did not apply to a hard failure."
::= { wanAtmStatsEntry 15 }
wanAtmStatsOutUnsuccessfulCalls OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is incremented when a RELEASE, RELEASE COMPLETE
(only when not preceded by a RELEASE mesg for the same call),
ADD PARTY REJECT, or STATUS message that contains one of the
following cause code values is transmitted (Note: These cause
values apply to both UNI3.0 and UNI3.1):
Cause Value Meaning
17 user busy
18 no user responding
21 call rejected
22 number changed
23 user rejects all calls with
calling line id restriction (CLIR)
27 destination out of order
31 normal, unspecified
88 incompatible destination
NOTE: For this counter, RELEASE COMPLETE messages that are a
reply to a previous RELEASE message and contain the same cause
value, are redundant(for counting purposes) and should not be
counted.
Note: Cause Value #30 'response to STATUS ENQUIRY' was not
included in this memo since it did not apply to a hard failure."
::= { wanAtmStatsEntry 16 }
wanAtmStatsInIncorrectMsgs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Incorrect Messages Counter reflects any sort of incorrect
information in a message. This includes:
? RELEASE, RELEASE COMPLETE, ADD PARTY REJECT, and
STATUS messages transmitted or received, that contain any of
the Cause values listed below.
? Ignored messages. These messages are dropped because the
message was so damaged that it could not be further processed.
A list of dropped messages is compiled below:
Message with invalid protocol discriminator
Message with errors in the call reference I.E.
? Bits 5-8 of the first octet not equal to '0000'
? Bits 1-4 of the first octet indicating a length other than
3 octets
? RELEASE COMPLETE message received with a call
reference that does not relate to a call active or in progress
? SETUP message received with call reference flag incorrectly
set to 1
? SETUP message received with a call reference for a call that is
already active or in progress.
Message too short
The following cause values are monitored by this counter
(Note: These cause values apply to both UNI3.0 and UNI3.1 unless
otherwise stated)
Cause Value Meaning
10 VPCI/VCI unacceptable (UNI3.0 only)
36 VPCI/VCI assignment failure (UNI3.1 only)
81 invalid call reference value
82 identified channel does not exist
89 invalid endpoint reference
96 mandatory information element is missing
97 message type non-existent or not
implemented
99 information element non-existent or not
implemented
100 invalid information element contents
101 message not compatible with call state
104 incorrect message length
111 protocol error, unspecified
NOTE: For this counter, RELEASE COMPLETE messages that are a
reply to a previous RELEASE message and contain the same cause
value, are redundant (for counting purposes) and should not be
counted."
::= { wanAtmStatsEntry 17 }
wanAtmStatsOutIncorrectMsgs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Incorrect Messages Counter reflects any sort of incorrect
information in a message. This includes:
? RELEASE, RELEASE COMPLETE, ADD PARTY REJECT, and
STATUS messages transmitted or received, that contain any of
the Cause values listed below.
? Ignored messages. These messages are dropped because the
message was so damaged that it could not be further processed.
A list of dropped messages is compiled below:
Message with invalid protocol discriminator
Message with errors in the call reference I.E.
? Bits 5-8 of the first octet not equal to '0000'
? Bits 1-4 of the first octet indicating a length other than
3 octets
? RELEASE COMPLETE message received with a call reference that
does not relate to a call active or in progress
? SETUP message received with call reference flag incorrectly
set to 1
? SETUP message received with a call reference for a call that is
already active or in progress.
Message too short
The following cause values are monitored by this counter
Note: These cause values apply to both UNI3.0 and UNI3.1 unless
otherwise stated)
Cause Value Meaning
10 VPCI/VCI unacceptable (UNI3.0 only)
36 VPCI/VCI assignment failure (UNI3.1 only)
81 invalid call reference value
82 identified channel does not exist
89 invalid endpoint reference
96 mandatory information element is missing
97 message type non-existent or not
implemented
99 information element non-existent or not
implemented
100 invalid information element contents
101 message not compatible with call state
104 incorrect message length
111 protocol error, unspecified
NOTE: For this counter, RELEASE COMPLETE messages that are
a reply to a previous RELEASE message and contain the same
cause value, are redundant (for counting purposes) and should
not be counted."
::= { wanAtmStatsEntry 18 }
wanAtmStatsInPartyEvents OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter monitors error events that occur due to the
originating user doing something wrong. This counter is
incremented when a RELEASE, RELEASE COMPLETE (only when not
preceded by a RELEASE mesg for the same call), ADD PARTY REJECT,
or STATUS message that contains one of the following cause code
values is received (Note: These cause values apply to both
UNI3.0 and UNI3.1):
Cause Value Meaning
28 invalid number format (address incomplete)
43 access information discarded
57 bearer capability not authorized
65 bearer capability not implemented
73 unsupported combination of traffic
parameters
78 AAL parameters cannot be supported
(UNI3.1 only)
91 invalid transit network selection
93 AAL parameters cannot be supported
(UNI3.0 only)
NOTE: For this counter, RELEASE COMPLETE messages that are
a reply to a previous RELEASE message and contain the same cause
value, are redundant(for counting purposes) and should not be
counted."
::= { wanAtmStatsEntry 19 }
wanAtmStatsOutPartyEvents OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter monitors error events that occur due to the
originating user doing something wrong. This counter is
incremented when a RELEASE, RELEASE COMPLETE (only when not
preceded by a RELEASE mesg for the same call), ADD PARTY
REJECT, or STATUS message that contains one of the following
cause code values is transmitted (Note: These cause values
apply to both UNI3.0 and UNI3.1):
Cause Value Meaning
28 invalid number format (address incomplete)
43 access information discarded
57 bearer capability not authorized
65 bearer capability not implemented
73 unsupported combination of traffic
parameters
78 AAL parameters cannot be supported
(UNI3.1 only)
91 invalid transit network selection
93 AAL parameters cannot be supported
(UNI3.0 only)
NOTE: For this counter, RELEASE COMPLETE messages that are
a reply to a previous RELEASE message and contain the same
cause value, are redundant (for counting purposes) and should
not be counted."
::= { wanAtmStatsEntry 20 }
wanAtmStatsInExpiries OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Timer Expiries Counter provides a count of network timer
expiries, and to some extent, host or switch timer expiries.
The conditions for incrementing this counter are:
? Expiry of any network timer
? Receipt of a RELEASE or RELEASE COMPLETE message with
Cause #102, 'recovery on timer expiry'.
NOTE: For this counter, RELEASE COMPLETE messages that are a
reply to a previous RELEASE message and contain the same cause
value, are redundant (for counting purposes) and should not be
counted."
::= { wanAtmStatsEntry 21 }
wanAtmStatsOutExpiries OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Timer Expiries Counter provides a count of network timer
expiries, and to some extent, host or switch timer expiries.
The conditions for incrementing this counter are:
? Expiry of any network timer
? Receipt of a RELEASE or RELEASE COMPLETE message with
Cause #102, 'recovery on timer expiry'.
NOTE: For this counter, RELEASE COMPLETE messages that are a
reply to a previous RELEASE message and contain the same cause
value, are redundant (for counting purposes) and should not be
counted."
::= { wanAtmStatsEntry 22 }
wanAtmStatsInRestartErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Restart Activity Counter provides a count of host, switch,
or network restart activity. This counter is incremented when
receiving a RESTART message."
::= { wanAtmStatsEntry 23 }
wanAtmStatsOutRestartErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Restart Activity Counter provides a count of host, switch,
or network restart activity. This counter is incremented when
transmitting a RESTART message."
::= { wanAtmStatsEntry 24 }
wanAtmStatsInSVCs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SVC VCCs established at this signaling entity for incoming
connections."
::= { wanAtmStatsEntry 25 }
wanAtmStatsOutSVCs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SVC VCCs established at this signaling entity for outgoing
connections."
::= { wanAtmStatsEntry 26 }
wanAtmStatsInOCDs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An out of cell delineation from far end of the link."
::= { wanAtmStatsEntry 27 }
wanAtmStatsOutOCDs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An out of cell delineation from near end of the link."
::= { wanAtmStatsEntry 28 }
wanAtmStatsInLOCs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A loss of cell delineation error from far end of the link.
This is a persistent OCD condition."
::= { wanAtmStatsEntry 29 }
wanAtmStatsOutLOCs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A loss of cell delineation error from near end of link.
This is a persistent OCD condition."
::= { wanAtmStatsEntry 30 }
wanAtmStatsInLOFs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A loss of frame error from far end of link."
::= { wanAtmStatsEntry 31 }
wanAtmStatsOutLOFs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A loss of frame error from near end of link."
::= { wanAtmStatsEntry 32 }
wanAtmStatsInLOPs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A loss of pointer error from far end of link."
::= { wanAtmStatsEntry 33 }
wanAtmStatsOutLOPs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A loss of pointer error from near end of link."
::= { wanAtmStatsEntry 34 }
wanAtmStatsInLOSs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A loss of signal error from far end of link."
::= { wanAtmStatsEntry 35 }
wanAtmStatsOutLOSs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A loss of signal error from near end of link."
::= { wanAtmStatsEntry 36 }
wanAtmStatsOwner OBJECT-TYPE
SYNTAX OwnerString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The entity that configured this entry."
::= { wanAtmStatsEntry 37 }
wanAtmStatsStatus OBJECT-TYPE
SYNTAX RowStatus
-- MAX-ACCESS read-write
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this wanAtmStatsTable entry."
::= { wanAtmStatsEntry 38 }
wanAtmHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF WanAtmHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"ATM signaling statistics."
::= { wanSignalingHistory 5 }
wanAtmHistoryEntry OBJECT-TYPE
SYNTAX WanAtmHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The statistics for an ATM interface. The near end of the link
refers to the side of the link that the probe is monitoring.
The far end is the side the probe is not on. In an ATM network,
there are many far ends of the link, but they shall be logically
grouped into one end in this table."
INDEX { wanAtmHistoryIndex, wanAtmHistorySampleIndex }
::= { wanAtmHistoryTable 1 }
WanAtmHistoryEntry ::= SEQUENCE {
wanAtmHistoryIndex INTEGER (1..65535),
wanAtmHistorySampleIndex INTEGER (1..2147483647),
wanAtmHistoryIntervalStart TimeTicks,
wanAtmHistoryDropEvents Counter64,
wanAtmHistoryInCells Counter64,
wanAtmHistoryOutCells Counter64,
wanAtmHistoryInCLP1 Counter64,
wanAtmHistoryOutCLP1 Counter64,
wanAtmHistoryConnectionEvents Counter64,
wanAtmHistoryErroredPDUs Counter64,
wanAtmHistorySetupAttempts Counter64,
wanAtmHistoryInRoutesUnavailable Counter64,
wanAtmHistoryOutRoutesUnavailable Counter64,
wanAtmHistoryInResourcesUnavailable Counter64,
wanAtmHistoryOutResourcesUnavailable Counter64,
wanAtmHistoryInUnsuccessfulCalls Counter64,
wanAtmHistoryOutUnsuccessfulCalls Counter64,
wanAtmHistoryInIncorrectMsgs Counter64,
wanAtmHistoryOutIncorrectMsgs Counter64,
wanAtmHistoryInPartyEvents Counter64,
wanAtmHistoryOutPartyEvents Counter64,
wanAtmHistoryInExpiries Counter64,
wanAtmHistoryOutExpiries Counter64,
wanAtmHistoryInRestartErrors Counter64,
wanAtmHistoryOutRestartErrors Counter64,
wanAtmHistoryInSVCs Counter64,
wanAtmHistoryOutSVCs Counter64,
wanAtmHistoryInOCDs Counter64,
wanAtmHistoryOutOCDs Counter64,
wanAtmHistoryInLOCs Counter64,
wanAtmHistoryOutLOCs Counter64,
wanAtmHistoryInLOFs Counter64,
wanAtmHistoryOutLOFs Counter64,
wanAtmHistoryInLOPs Counter64,
wanAtmHistoryOutLOPs Counter64,
wanAtmHistoryInLOSs Counter64,
wanAtmHistoryOutLOSs Counter64,
wanAtmHistoryInUtilization INTEGER (0..10000),
wanAtmHistoryOutUtilization INTEGER (0..10000)
}
wanAtmHistoryIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The history of which this entry is a port. The history
identified by a particular value of this index is the same
history as identified by the same value of
historyControlIndex."
::= { wanAtmHistoryEntry 1 }
wanAtmHistorySampleIndex OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An index that uniquely identifies the particular sample this
entry represents among all samples associated with the same
historyControlEntry. This index starts at 1 and increases
by one as each new sample is taken."
::= { wanAtmHistoryEntry 2 }
wanAtmHistoryIntervalStart OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime at the start of the interval over which
this sample was measured. If the probe keeps track of time of
day, it should start the first sample of the history at a time
such that when the next hour of the day begins, a sample is
started at that instant. Note that following this rule may
require the probe to delay collection the first sample of the
history, as each sample must be of the same interval. Also
note that the sample which is currently being collected is not
accessible in this table until the end of its interval."
::= { wanAtmHistoryEntry 3 }
wanAtmHistoryDropEvents OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAtmStatsDropEvents during the
interval."
::= { wanAtmHistoryEntry 4 }
wanAtmHistoryInCells OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAtmStatsInCells during the
interval."
::= { wanAtmHistoryEntry 5 }
wanAtmHistoryOutCells OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAtmStatsOutCells during the
interval."
::= { wanAtmHistoryEntry 6 }
wanAtmHistoryInCLP1 OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAtmStatsInCLP1 during the
interval."
::= { wanAtmHistoryEntry 7 }
wanAtmHistoryOutCLP1 OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAtmStatsOutCLP1 during the
interval."
::= { wanAtmHistoryEntry 8 }
wanAtmHistoryConnectionEvents OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAtmStatsConnectionEvents during the
interval."
::= { wanAtmHistoryEntry 9 }
wanAtmHistoryErroredPDUs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAtmStatsErroredPDUs during the
interval."
::= { wanAtmHistoryEntry 10 }
wanAtmHistorySetupAttempts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAtmStatsSetupAttempts during the
interval."
::= { wanAtmHistoryEntry 11 }
wanAtmHistoryInRoutesUnavailable OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAtmStatsInRoutesUnavailable
during the interval."
::= { wanAtmHistoryEntry 12 }
wanAtmHistoryOutRoutesUnavailable OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAtmStatsOutRoutesUnavailable
during the interval."
::= { wanAtmHistoryEntry 13 }
wanAtmHistoryInResourcesUnavailable OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAtmStatsInResourcesUnavailable
during the interval."
::= { wanAtmHistoryEntry 14 }
wanAtmHistoryOutResourcesUnavailable OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAtmStatsOutResourcesUnavailable
during the interval."
::= { wanAtmHistoryEntry 15 }
wanAtmHistoryInUnsuccessfulCalls OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAtmStatsInUnsuccessfulCalls
during the interval."
::= { wanAtmHistoryEntry 16 }
wanAtmHistoryOutUnsuccessfulCalls OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAtmStatsOutUnsuccessfulCalls
during the interval."
::= { wanAtmHistoryEntry 17 }
wanAtmHistoryInIncorrectMsgs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAtmStatsInIncorrectMsgs
during the interval."
::= { wanAtmHistoryEntry 18 }
wanAtmHistoryOutIncorrectMsgs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAtmStatsOutIncorrectMsgs
during the interval."
::= { wanAtmHistoryEntry 19 }
wanAtmHistoryInPartyEvents OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAtmStatsInPartyEvents
during the interval."
::= { wanAtmHistoryEntry 20 }
wanAtmHistoryOutPartyEvents OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAtmStatsOutPartyEvents
during the interval."
::= { wanAtmHistoryEntry 21 }
wanAtmHistoryInExpiries OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAtmStatsInExpiries
during the interval."
::= { wanAtmHistoryEntry 22 }
wanAtmHistoryOutExpiries OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAtmStatsOutExpiries
during the interval."
::= { wanAtmHistoryEntry 23 }
wanAtmHistoryInRestartErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAtmStatsInRestartErrors
during the interval."
::= { wanAtmHistoryEntry 24 }
wanAtmHistoryOutRestartErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAtmStatsOutRestartErrors
during the interval."
::= { wanAtmHistoryEntry 25 }
wanAtmHistoryInSVCs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAtmStatsInSVCs during the
interval."
::= { wanAtmHistoryEntry 26 }
wanAtmHistoryOutSVCs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAtmStatsOutSVCs during the
interval."
::= { wanAtmHistoryEntry 27 }
wanAtmHistoryInOCDs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAtmStatsInOCDs during the
interval."
::= { wanAtmHistoryEntry 28 }
wanAtmHistoryOutOCDs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAtmStatsOutOCDs during the
interval."
::= { wanAtmHistoryEntry 29 }
wanAtmHistoryInLOCs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAtmStatsInLOCs during the
interval."
::= { wanAtmHistoryEntry 30 }
wanAtmHistoryOutLOCs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAtmStatsOutLOCs during the
interval."
::= { wanAtmHistoryEntry 31 }
wanAtmHistoryInLOFs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAtmStatsInLOFs during the
interval."
::= { wanAtmHistoryEntry 32 }
wanAtmHistoryOutLOFs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAtmStatsOutLOFs during the
interval."
::= { wanAtmHistoryEntry 33 }
wanAtmHistoryInLOPs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAtmStatsInLOPs during the
interval."
::= { wanAtmHistoryEntry 34 }
wanAtmHistoryOutLOPs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAtmStatsOutLOPs during the
interval."
::= { wanAtmHistoryEntry 35 }
wanAtmHistoryInLOSs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAtmStatsInLOSs during the
interval."
::= { wanAtmHistoryEntry 36 }
wanAtmHistoryOutLOSs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAtmStatsOutLOSs during the
interval."
::= { wanAtmHistoryEntry 37 }
wanAtmHistoryInUtilization OBJECT-TYPE
SYNTAX INTEGER (0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The best estimated of the mean physical layer network
utilization of traffic coming from the far end of the link
in hundreds of a percent."
::= { wanAtmHistoryEntry 38 }
wanAtmHistoryOutUtilization OBJECT-TYPE
SYNTAX INTEGER (0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The best estimated of the mean physical layer network
utilization of traffic coming from the near end of the
link in hundreds of a percent."
::= { wanAtmHistoryEntry 39 }
wanX25StatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF WanX25StatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"X.25 Packet layer statistics."
::= { wanProtocolStats 1 }
wanX25StatsEntry OBJECT-TYPE
SYNTAX WanX25StatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The statistics for an X.25 interface across all LCIs. The near
end of the link refers to the side of the link that the probe is
monitoring. The far end is the side the probe is not on. In an
X.25 network, there are many far ends of the link, but they
shall be logically grouped into one end in this table."
INDEX { wanX25StatsIndex }
::= { wanX25StatsTable 1 }
WanX25StatsEntry ::= SEQUENCE {
wanX25StatsIndex INTEGER (1..65535),
wanX25StatsDataSource OBJECT IDENTIFIER,
wanX25StatsDropEvents Counter64,
wanX25StatsInFrames Counter64,
wanX25StatsOutFrames Counter64,
wanX25StatsInOctets Counter64,
wanX25StatsOutOctets Counter64,
wanX25StatsInRejects Counter64,
wanX25StatsOutRejects Counter64,
wanX25StatsInAttempts Counter64,
wanX25StatsOutAttempts Counter64,
wanX25StatsInFailures Counter64,
wanX25StatsOutFailures Counter64,
wanX25StatsProviderClears Counter64,
wanX25StatsInResets Counter64,
wanX25StatsOutResets Counter64,
wanX25StatsProviderResets Counter64,
wanX25StatsInAccusedErrors Counter64,
wanX25StatsOutAccusedErrors Counter64,
wanX25StatsInInterrupts Counter64,
wanX25StatsOutInterrupts Counter64,
wanX25StatsOwner OwnerString,
wanX25StatsStatus RowStatus
}
wanX25StatsIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of this object uniquely identifies this wanX25StatsTable entry."
::= { wanX25StatsEntry 1 }
wanX25StatsDataSource OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object identifies the source of the data that this
wanX25StatsEntry analyzes. This source can be any interface
on this device. In order to identify a particular interface,
this object shall identify the instance of the ifIndex object,
defined in MIB-II [RFC 1573] for the desired interface. The
ifType value associated with the ifIndex can only be
rfc887-x25(5)."
::= { wanX25StatsEntry 2 }
wanX25StatsDropEvents OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of events in which frames were dropped by
the probe due to lack of resources. Note that this number is
not necessarily the number of frames dropped; it is just the
number of times this condition has been detected."
::= { wanX25StatsEntry 3 }
wanX25StatsInFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames seen coming from the far end of
the link including error packets."
::= { wanX25StatsEntry 4 }
wanX25StatsOutFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames seen coming from the near end of
the link including error packets."
::= { wanX25StatsEntry 5 }
wanX25StatsInOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The sum of octets from all frames seen originating from the
far end of the link including errored frames."
::= { wanX25StatsEntry 6 }
wanX25StatsOutOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The sum of octets from all frames seen originating from the
near end of the link including errored frames."
::= { wanX25StatsEntry 7 }
wanX25StatsInRejects OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of REJ or SREJ frames see coming from the far end
of the link."
::= { wanX25StatsEntry 8 }
wanX25StatsOutRejects OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of REJ or SREJ frames see coming from the near end
of the link."
::= { wanX25StatsEntry 9 }
wanX25StatsInAttempts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of call setup attempts initiated from the far end
of the link."
::= { wanX25StatsEntry 10 }
wanX25StatsOutAttempts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of call setup attempts initiated from the near end
of the link."
::= { wanX25StatsEntry 11 }
wanX25StatsInFailures OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number call setup attempt failures seen coming from the
far end of the link."
::= { wanX25StatsEntry 12 }
wanX25StatsOutFailures OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number call setup attempt failures seen coming from the
near end of the link."
::= { wanX25StatsEntry 13 }
wanX25StatsProviderClears OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of clear request seen with a cause code other than DTE
initiated."
::= { wanX25StatsEntry 14 }
wanX25StatsInResets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of reset requests seen from the far end of the link
with cause code DTE initiated."
::= { wanX25StatsEntry 15 }
wanX25StatsOutResets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of reset requests seen from the near end of the link
with cause code DTE initiated."
::= { wanX25StatsEntry 16 }
wanX25StatsProviderResets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of reset requests seen with cause code other than DTE
initiated."
::= { wanX25StatsEntry 17 }
wanX25StatsInAccusedErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The numbers of packets seen from the far end of the link
containing a procedure error cause code. These include clear,
reset, restart, or diagnostic packets."
::= { wanX25StatsEntry 18 }
wanX25StatsOutAccusedErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The numbers of packets seen from the near end of the link
containing a procedure error cause code. These include clear,
reset, restart, or diagnostic packets."
::= { wanX25StatsEntry 19 }
wanX25StatsInInterrupts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of interrupts packets seen coming from the far end
of the link over all VCs."
::= { wanX25StatsEntry 20 }
wanX25StatsOutInterrupts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of interrupts packets seen coming from the near end
of the link over all VCs."
::= { wanX25StatsEntry 21 }
wanX25StatsOwner OBJECT-TYPE
SYNTAX OwnerString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The entity that configured this entry."
::= { wanX25StatsEntry 22 }
wanX25StatsStatus OBJECT-TYPE
SYNTAX RowStatus
-- MAX-ACCESS read-write
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this wanX25StatsTable entry."
::= { wanX25StatsEntry 23 }
wanX25HistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF WanX25HistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"X.25 Packet layer statistics."
::= { wanProtocolHistory 1 }
wanX25HistoryEntry OBJECT-TYPE
SYNTAX WanX25HistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The statistics for an X.25 interface across all LCIs. The near
end of the link refers to the side of the link that the probe
is monitoring. The far end is the side the probe is not on.
In a X.25 network, there are many far ends of the link, but
they shall be logically grouped into one end in this table."
INDEX { wanX25HistoryIndex, wanX25HistorySampleIndex }
::= { wanX25HistoryTable 1 }
WanX25HistoryEntry ::= SEQUENCE {
wanX25HistoryIndex INTEGER(1..65535),
wanX25HistorySampleIndex INTEGER (1..2147483647),
wanX25HistoryIntervalStart TimeTicks,
wanX25HistoryDropEvents Counter64,
wanX25HistoryInFrames Counter64,
wanX25HistoryOutFrames Counter64,
wanX25HistoryInOctets Counter64,
wanX25HistoryOutOctets Counter64,
wanX25HistoryInRejects Counter64,
wanX25HistoryOutRejects Counter64,
wanX25HistoryInAttempts Counter64,
wanX25HistoryOutAttempts Counter64,
wanX25HistoryInFailures Counter64,
wanX25HistoryOutFailures Counter64,
wanX25HistoryProviderClears Counter64,
wanX25HistoryInResets Counter64,
wanX25HistoryOutResets Counter64,
wanX25HistoryProviderResets Counter64,
wanX25HistoryInAccusedErrors Counter64,
wanX25HistoryOutAccusedErrors Counter64,
wanX25HistoryInInterrupts Counter64,
wanX25HistoryOutInterrupts Counter64,
wanX25HistoryInUtilization INTEGER (0..10000),
wanX25HistoryOutUtilization INTEGER (0..10000)
}
wanX25HistoryIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The history of which this entry is a port. The history
identified by a particular value of this index is the same
history as identified by the same value of
historyControlIndex."
::= { wanX25HistoryEntry 1 }
wanX25HistorySampleIndex OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An index that uniquely identifies the particular sample this
entry represents among all samples associated with the same
historyControlEntry. This index starts at 1 and increases
by one as each new sample is taken."
::= { wanX25HistoryEntry 2 }
wanX25HistoryIntervalStart OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime at the start of the interval over which
this sample was measured. If the probe keeps track of time of
day, it should start the first sample of the history at a time
such that when the next hour of the day begins, a sample is
started at that instant. Note that following this rule may
require the probe to delay collection the first sample of the
history, as each sample must be of the same interval. Also
note that the sample which is currently being collected is not
accessible in this table until the end of its interval."
::= { wanX25HistoryEntry 3 }
wanX25HistoryDropEvents OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanX25StatsDropEvents during the
interval."
::= { wanX25HistoryEntry 4 }
wanX25HistoryInFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanX25StatsInFrames during the
interval."
::= { wanX25HistoryEntry 5 }
wanX25HistoryOutFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanX25StatsOutFrames during the
interval."
::= { wanX25HistoryEntry 6 }
wanX25HistoryInOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanX25StatsInOctets during the
interval."
::= { wanX25HistoryEntry 7 }
wanX25HistoryOutOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanX25StatsOutOctets during the
interval."
::= { wanX25HistoryEntry 8 }
wanX25HistoryInRejects OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanX25StatsInRejects during the
interval."
::= { wanX25HistoryEntry 9 }
wanX25HistoryOutRejects OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanX25StatsOutRejects during the
interval."
::= { wanX25HistoryEntry 10 }
wanX25HistoryInAttempts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanX25StatsInAttempts during the
interval."
::= { wanX25HistoryEntry 11 }
wanX25HistoryOutAttempts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanX25StatsOutAttempts during the
interval."
::= { wanX25HistoryEntry 12 }
wanX25HistoryInFailures OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanX25StatsInFailures during the
interval."
::= { wanX25HistoryEntry 13 }
wanX25HistoryOutFailures OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanX25StatsOutFailures during the
interval."
::= { wanX25HistoryEntry 14 }
wanX25HistoryProviderClears OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanX25StatsProviderClears during the
interval."
::= { wanX25HistoryEntry 15 }
wanX25HistoryInResets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanX25StatsInResets during the
interval."
::= { wanX25HistoryEntry 16 }
wanX25HistoryOutResets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanX25StatsOutResets during the
interval."
::= { wanX25HistoryEntry 17 }
wanX25HistoryProviderResets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanX25StatsProviderResets during the
interval."
::= { wanX25HistoryEntry 18 }
wanX25HistoryInAccusedErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanX25StatsInAccusedErrors during the
interval."
::= { wanX25HistoryEntry 19 }
wanX25HistoryOutAccusedErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanX25StatsOutAccusedErrors during the
interval."
::= { wanX25HistoryEntry 20 }
wanX25HistoryInInterrupts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanX25StatsInInterrupts during the
interval."
::= { wanX25HistoryEntry 21 }
wanX25HistoryOutInterrupts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanX25StatsOutInterrupts during the
interval."
::= { wanX25HistoryEntry 22 }
wanX25HistoryInUtilization OBJECT-TYPE
SYNTAX INTEGER (0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The best estimated of the mean physical layer network
utilization of traffic coming from the far end of the link
in hundreds of a percent."
::= { wanX25HistoryEntry 23 }
wanX25HistoryOutUtilization OBJECT-TYPE
SYNTAX INTEGER (0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The best estimated of the mean physical layer network
utilization of traffic coming from the near end of the link
in hundreds of a percent."
::= { wanX25HistoryEntry 24 }
wanFrStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF WanFrStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Frame Relay statistics."
::= { wanProtocolStats 2 }
wanFrStatsEntry OBJECT-TYPE
SYNTAX WanFrStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The statistics for a frame relay interface across all DLCIs.
The near end of the link refers to the side of the link that the
probe is monitoring. The far end is the side the probe is not
on. In a frame relay network, there are many far ends of the
link, but they shall be logically grouped into one end in this
table."
INDEX { wanFrStatsIndex }
::= { wanFrStatsTable 1 }
WanFrStatsEntry ::= SEQUENCE {
wanFrStatsIndex INTEGER (1..65535),
wanFrStatsDataSource OBJECT IDENTIFIER,
wanFrStatsDropEvents Counter64,
wanFrStatsInFrames Counter64,
wanFrStatsOutFrames Counter64,
wanFrStatsInOctets Counter64,
wanFrStatsOutOctets Counter64,
wanFrStatsInFECNs Counter64,
wanFrStatsOutFECNs Counter64,
wanFrStatsInBECNs Counter64,
wanFrStatsOutBECNs Counter64,
wanFrStatsInDEs Counter64,
wanFrStatsOutDEs Counter64,
wanFrStatsOwner OwnerString,
wanFrStatsStatus RowStatus
}
wanFrStatsIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of this object uniquely identifies this
wanFrStatsTable entry."
::= { wanFrStatsEntry 1 }
wanFrStatsDataSource OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object identifies the source of the data that this
wanFrStatsEntry analyzes. This source can be any frame relay
interface on this device. In order to identify a particular
interface, this object shall identify the instance of the
ifIndex object, defined in MIB-II [RFC 1573] for the desired
interface. The ifType value associated with the ifIndex can
only be frameRelay(32)."
::= { wanFrStatsEntry 2 }
wanFrStatsDropEvents OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of events in which frames were dropped by the
probe due to lack of resources. Note that this number is not
necessarily the number of frames dropped; it is just the number
of times this condition has been detected."
::= { wanFrStatsEntry 3 }
wanFrStatsInFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames seen coming from the far end of
the link including error packets."
::= { wanFrStatsEntry 4 }
wanFrStatsOutFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames seen coming from the near end of
the link including error packets."
::= { wanFrStatsEntry 5 }
wanFrStatsInOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The sum of octets from all frames seen originating from the
far end of the link including errored frames."
::= { wanFrStatsEntry 6 }
wanFrStatsOutOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The sum of octets from all frames seen originating from the
near end of the link including errored frames."
::= { wanFrStatsEntry 7 }
wanFrStatsInFECNs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames see coming form the far end of the link
with the FECN bit set."
::= { wanFrStatsEntry 8 }
wanFrStatsOutFECNs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames see coming form the near end of the link
with the FECN bit set."
::= { wanFrStatsEntry 9 }
wanFrStatsInBECNs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames seen coming from the far end of the link
with the BECN bit set."
::= { wanFrStatsEntry 10 }
wanFrStatsOutBECNs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames seen coming from the near end of the link
with the BECN bit set."
::= { wanFrStatsEntry 11 }
wanFrStatsInDEs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames seen coming from the far end of the link
with the DE bit set."
::= { wanFrStatsEntry 12 }
wanFrStatsOutDEs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames seen coming from the near end of the link
with the DE bit set."
::= { wanFrStatsEntry 13 }
wanFrStatsOwner OBJECT-TYPE
SYNTAX OwnerString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The entity that configured this entry."
::= { wanFrStatsEntry 14 }
wanFrStatsStatus OBJECT-TYPE
SYNTAX RowStatus
-- MAX-ACCESS read-write
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this wanFrStatsTable entry."
::= { wanFrStatsEntry 15 }
wanFrHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF WanFrHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Frame Relay statistics."
::= { wanProtocolHistory 2 }
wanFrHistoryEntry OBJECT-TYPE
SYNTAX WanFrHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The statistics for a frame relay interface across all DLCIs. The
near end of the link refers to the side of the link that the
probe is monitoring. The far end is the side the probe is not
on. In a frame relay network, there are many far ends of the
link, but they shall be logically grouped into one end in this
table."
INDEX { wanFrHistoryIndex, wanFrHistorySampleIndex }
::= { wanFrHistoryTable 1 }
WanFrHistoryEntry ::= SEQUENCE {
wanFrHistoryIndex INTEGER (1..65535),
wanFrHistorySampleIndex INTEGER (1..2147483647),
wanFrHistoryIntervalStart TimeTicks,
wanFrHistoryDropEvents Counter64,
wanFrHistoryInFrames Counter64,
wanFrHistoryOutFrames Counter64,
wanFrHistoryInOctets Counter64,
wanFrHistoryOutOctets Counter64,
wanFrHistoryInFECNs Counter64,
wanFrHistoryOutFECNs Counter64,
wanFrHistoryInBECNs Counter64,
wanFrHistoryOutBECNs Counter64,
wanFrHistoryInDEs Counter64,
wanFrHistoryOutDEs Counter64,
wanFrHistoryInUtilization INTEGER (0..10000),
wanFrHistoryOutUtilization INTEGER (0..10000)
}
wanFrHistoryIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The history of which this entry is a port. The history
identified by a particular value of this index is the same
history as identified by the same value of
historyControlIndex."
::= { wanFrHistoryEntry 1 }
wanFrHistorySampleIndex OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An index that uniquely identifies the particular sample this
entry represents among all samples associated with the same
historyControlEntry. This index starts at 1 and increases by
one as each new sample is taken."
::= { wanFrHistoryEntry 2 }
wanFrHistoryIntervalStart OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime at the start of the interval over which
this sample was measured. If the probe keeps track of time of
day, it should start the first sample of the history at a time
such that when the next hour of the day begins, a sample is
started at that instant. Note that following this rule may
require the probe to delay collection the first sample of the
history, as each sample must be of the same interval. Also
note that the sample which is currently being collected is not
accessible in this table until the end of its interval."
::= { wanFrHistoryEntry 3 }
wanFrHistoryDropEvents OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanFrStatsDropEvents during the
interval."
::= { wanFrHistoryEntry 4 }
wanFrHistoryInFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanFrStatsInFrames during the
interval."
::= { wanFrHistoryEntry 5 }
wanFrHistoryOutFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanFrStatsOutFrames during the
interval."
::= { wanFrHistoryEntry 6 }
wanFrHistoryInOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanFrStatsInOctets during the
interval."
::= { wanFrHistoryEntry 7 }
wanFrHistoryOutOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanFrStatsOutOctets during the
interval."
::= { wanFrHistoryEntry 8 }
wanFrHistoryInFECNs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanFrStatsInFECSs during the
interval."
::= { wanFrHistoryEntry 9 }
wanFrHistoryOutFECNs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanFrStatsOutFECNs during the
interval."
::= { wanFrHistoryEntry 10 }
wanFrHistoryInBECNs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanFrStatsInBECNs during the
interval."
::= { wanFrHistoryEntry 11 }
wanFrHistoryOutBECNs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanFrStatsOutBECNs during the
interval."
::= { wanFrHistoryEntry 12 }
wanFrHistoryInDEs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanFrStatsInDEs during the interval."
::= { wanFrHistoryEntry 13 }
wanFrHistoryOutDEs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanFrStatsDOutDEs during the interval."
::= { wanFrHistoryEntry 14 }
wanFrHistoryInUtilization OBJECT-TYPE
SYNTAX INTEGER (0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The best estimated of the mean physical layer network
utilization of traffic coming from the far end of the link
in hundreds of a percent."
::= { wanFrHistoryEntry 15 }
wanFrHistoryOutUtilization OBJECT-TYPE
SYNTAX INTEGER (0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The best estimated of the mean physical layer network
utilization of traffic coming from the near end of the link
in hundreds of a percent."
::= { wanFrHistoryEntry 16 }
wanAal5StatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF WanAal5StatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"AAL/5 statistics."
::= { wanProtocolStats 3 }
wanAal5StatsEntry OBJECT-TYPE
SYNTAX WanAal5StatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The statistics for a AAL/5 interface. The near end of the link
refers to the side of the link that the probe is monitoring.
The far end is the side the probe is not on. In an ATM network,
there are many far ends of the link, but they shall be logically
grouped into one end in this table."
INDEX { wanAal5StatsIndex }
::= { wanAal5StatsTable 1 }
WanAal5StatsEntry ::= SEQUENCE {
wanAal5StatsIndex INTEGER (1..65535),
wanAal5StatsDataSource OBJECT IDENTIFIER,
wanAal5StatsDropEvents Counter64,
wanAal5StatsInCells Counter64,
wanAal5StatsOutCells Counter64,
wanAal5StatsInPDUs Counter64,
wanAal5StatsOutPDUs Counter64,
wanAal5StatsInOctets Counter64,
wanAal5StatsOutOctets Counter64,
wanAal5StatsInCLP1 Counter64,
wanAal5StatsOutCLP1 Counter64,
wanAal5StatsInCRCs Counter64,
wanAal5StatsOutCRCs Counter64,
wanAal5StatsInOversizedSDUs Counter64,
wanAal5StatsOutOversizedSDUs Counter64,
wanAal5StatsInSVCs Counter64,
wanAal5StatsOutSVCs Counter64,
wanAal5StatsOwner OwnerString,
wanAal5StatsStatus RowStatus
}
wanAal5StatsIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of this object uniquely identifies this wanAal5StatsTable entry."
::= { wanAal5StatsEntry 1 }
wanAal5StatsDataSource OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object identifies the source of the data that this
wanAal5StatsEntry analyzes. This source can be any interface
on this device. In order to identify a particular interface,
this object shall identify the instance of the ifIndex object,
defined in MIB-II [RFC 1573] for the desired interface. The
ifType value associated with the ifIndex can only be aal5(49)."
::= { wanAal5StatsEntry 2 }
wanAal5StatsDropEvents OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of events in which frames were dropped by the
probe due to lack of resources. Note that this number is not
necessarily the number of frames dropped; it is just the
number of times this condition has been detected."
::= { wanAal5StatsEntry 3 }
wanAal5StatsInCells OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of cells for any AAL-5 connection seen
coming from the far end of the link."
::= { wanAal5StatsEntry 4 }
wanAal5StatsOutCells OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of cells for any AAL-5 connection seen
coming from the near end of the link."
::= { wanAal5StatsEntry 5 }
wanAal5StatsInPDUs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of AAL-5 PDUs seen coming from the far end
of the link including error PDUs."
::= { wanAal5StatsEntry 6 }
wanAal5StatsOutPDUs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of AAL-5 PDUs seen coming from the near end
of the link including error PDUs."
::= { wanAal5StatsEntry 7 }
wanAal5StatsInOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The sum of octets from all AAL-5 PDUs seen originating from
the far end of the link including errored PDUs."
::= { wanAal5StatsEntry 8 }
wanAal5StatsOutOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The sum of octets from all AAL-5 PDUs seen originating from
the near end of the link including errored PDUs."
::= { wanAal5StatsEntry 9 }
wanAal5StatsInCLP1 OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of cells for any AAL-5 connection with the
CLP bit set seen coming from the far end of the link."
::= { wanAal5StatsEntry 10 }
wanAal5StatsOutCLP1 OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of cells for any AAL-5 connection with the
CLP bit set seen coming from the near end of the link."
::= { wanAal5StatsEntry 11 }
wanAal5StatsInCRCs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of AAL-5 PDUs with CRC errors from the far
end of the link."
::= { wanAal5StatsEntry 12 }
wanAal5StatsOutCRCs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of AAL-5 PDUs with CRC errors from the
near end of the link."
::= { wanAal5StatsEntry 13 }
wanAal5StatsInOversizedSDUs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of AAL-5 SDUs from the far end of the link
that were too large."
::= { wanAal5StatsEntry 14 }
wanAal5StatsOutOversizedSDUs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of AAL-5 SDUs from the near end of the link
that were too large."
::= { wanAal5StatsEntry 15 }
wanAal5StatsInSVCs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of AAL/5 connections seen initiated from the
far end of the link."
::= { wanAal5StatsEntry 16 }
wanAal5StatsOutSVCs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of AAL-5 connections seen initiated from
the near end of the link."
::= { wanAal5StatsEntry 17 }
wanAal5StatsOwner OBJECT-TYPE
SYNTAX OwnerString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The entity that configured this entry."
::= { wanAal5StatsEntry 18 }
wanAal5StatsStatus OBJECT-TYPE
SYNTAX RowStatus
-- MAX-ACCESS read-write
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this wanAal5StatsTable entry."
::= { wanAal5StatsEntry 19 }
wanAal5HistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF WanAal5HistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"AAL/5 statistics."
::= { wanProtocolHistory 3 }
wanAal5HistoryEntry OBJECT-TYPE
SYNTAX WanAal5HistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The statistics for a AAL/5 interface. The near end of the link
refers to the side of the link that the probe is monitoring.
The far end is the side the probe is not on. In an ATM network,
there are many far ends of the link, but they shall be logically
grouped into one end in this table."
INDEX { wanAal5HistoryIndex, wanAal5HistorySampleIndex }
::= { wanAal5HistoryTable 1 }
WanAal5HistoryEntry ::= SEQUENCE {
wanAal5HistoryIndex INTEGER (1..65535),
wanAal5HistorySampleIndex INTEGER (1..2147483647),
wanAal5HistoryIntervalStart TimeTicks,
wanAal5HistoryDropEvents Counter64,
wanAal5HistoryInCells Counter64,
wanAal5HistoryOutCells Counter64,
wanAal5HistoryInPDUs Counter64,
wanAal5HistoryOutPDUs Counter64,
wanAal5HistoryInOctets Counter64,
wanAal5HistoryOutOctets Counter64,
wanAal5HistoryInCLP1 Counter64,
wanAal5HistoryOutCLP1 Counter64,
wanAal5HistoryInCRCs Counter64,
wanAal5HistoryOutCRCs Counter64,
wanAal5HistoryInOversizedSDUs Counter64,
wanAal5HistoryOutOversizedSDUs Counter64,
wanAal5HistoryInSVCs Counter64,
wanAal5HistoryOutSVCs Counter64,
wanAal5HistoryInUtilization INTEGER (0..10000),
wanAal5HistoryOutUtilization INTEGER (0..10000)
}
wanAal5HistoryIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The history of which this entry is a port. The history
identified by a particular value of this index is the same
history as identified by the same value of
historyControlIndex."
::= { wanAal5HistoryEntry 1 }
wanAal5HistorySampleIndex OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An index that uniquely identifies the particular sample
this entry represents among all samples associated with the
same historyControlEntry. This index starts at 1 and
increases by one as each new sample is taken."
::= { wanAal5HistoryEntry 2 }
wanAal5HistoryIntervalStart OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime at the start of the interval over
which this sample was measured. If the probe keeps track of
time of day, it should start the first sample of the history
at a time such that when the next hour of the day begins, a
sample is started at that instant. Note that following this
rule may require the probe to delay collection the first
sample of the history, as each sample must be of the same
interval. Also note that the sample which is currently being
collected is not accessible in this table until the end of its
interval."
::= { wanAal5HistoryEntry 3 }
wanAal5HistoryDropEvents OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAal5StatsDropEvents during the
interval."
::= { wanAal5HistoryEntry 4 }
wanAal5HistoryInCells OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAal5StatsInCells during the
interval."
::= { wanAal5HistoryEntry 5 }
wanAal5HistoryOutCells OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAal5StatsOutCells during the
interval."
::= { wanAal5HistoryEntry 6 }
wanAal5HistoryInPDUs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAal5StatsInPDUs during the
interval."
::= { wanAal5HistoryEntry 7 }
wanAal5HistoryOutPDUs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAal5StatsOutPDUs during the
interval."
::= { wanAal5HistoryEntry 8 }
wanAal5HistoryInOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAal5StatsInOctets during the
interval."
::= { wanAal5HistoryEntry 9 }
wanAal5HistoryOutOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAal5StatsOutOctets during the
interval."
::= { wanAal5HistoryEntry 10 }
wanAal5HistoryInCLP1 OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAal5StatsInCLP1 the
interval."
::= { wanAal5HistoryEntry 11 }
wanAal5HistoryOutCLP1 OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAal5StatsOutCLP1 during the
interval."
::= { wanAal5HistoryEntry 12 }
wanAal5HistoryInCRCs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAal5StatsInCRCs during the
interval."
::= { wanAal5HistoryEntry 13 }
wanAal5HistoryOutCRCs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAal5StatsOutCRCs during the
interval."
::= { wanAal5HistoryEntry 14 }
wanAal5HistoryInOversizedSDUs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAal5StatsInOversizedSDUs during the
interval."
::= { wanAal5HistoryEntry 15 }
wanAal5HistoryOutOversizedSDUs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAal5StatsOutOversizedSDUs during the
interval."
::= { wanAal5HistoryEntry 16 }
wanAal5HistoryInSVCs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAal5StatsInSVCs during the
interval."
::= { wanAal5HistoryEntry 17 }
wanAal5HistoryOutSVCs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAal5StatsOutSVCs during the
interval."
::= { wanAal5HistoryEntry 18 }
wanAal5HistoryInUtilization OBJECT-TYPE
SYNTAX INTEGER (0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The best estimated of the mean AAL-5 layer network
utilization of traffic coming from the far end of the
link in hundreds of a percent."
::= { wanAal5HistoryEntry 19 }
wanAal5HistoryOutUtilization OBJECT-TYPE
SYNTAX INTEGER (0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The best estimated of the mean AAL-5 layer network
utilization of traffic coming from the near end of the
link in hundreds of a percent."
::= { wanAal5HistoryEntry 20 }
wanPppStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF WanPppStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"PPP in HDLC service statistics."
::= { wanProtocolStats 4 }
wanPppStatsEntry OBJECT-TYPE
SYNTAX WanPppStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The statistics for a PPP in HDLC service. The near end of
the link refers to the side of the link that the probe is
monitoring. The far end is the side the probe is not on."
INDEX { wanPppStatsIndex }
::= { wanPppStatsTable 1 }
WanPppStatsEntry ::= SEQUENCE {
wanPppStatsIndex INTEGER (1..65535),
wanPppStatsDataSource OBJECT IDENTIFIER,
wanPppStatsDropEvents Counter64,
wanPppStatsInFrames Counter64,
wanPppStatsOutFrames Counter64,
wanPppStatsInOctets Counter64,
wanPppStatsOutOctets Counter64,
wanPppStatsInBadAddresses Counter64,
wanPppStatsOutBadAddresses Counter64,
wanPppStatsInBadControls Counter64,
wanPppStatsOutBadControls Counter64,
wanPppStatsInLongFrames Counter64,
wanPppStatsOutLongFrames Counter64,
wanPppStatsInBadFCSs Counter64,
wanPppStatsOutBadFCSs Counter64,
wanPppStatsOwner OwnerString,
wanPppStatsStatus RowStatus
}
wanPppStatsIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of this object uniquely identifies this wanPppStatsTable entry."
::= { wanPppStatsEntry 1 }
wanPppStatsDataSource OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object identifies the source of the data that this
wanPppStatsEntry analyzes. This source can be any interface
on this device. In order to identify a particular interface,
this object shall identify the instance of the ifIndex object,
defined in MIB-II [RFC 1573] for the desired interface. The
ifType value associated with the ifIndex can only be ppp(22)."
::= {wanPppStatsEntry 2 }
wanPppStatsDropEvents OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of events in which frames were dropped by
the probe due to lack of resources. Note that this number
is not necessarily the number of frames dropped; it is just
the number of times this condition has been detected."
::= { wanPppStatsEntry 3 }
wanPppStatsInFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames seen coming from the far end
of the link including error frames."
::= { wanPppStatsEntry 4 }
wanPppStatsOutFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames seen coming from the near end
of the link including error frames."
::= { wanPppStatsEntry 5 }
wanPppStatsInOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The sum of octets from all frames seen coming from the far
end of the link including errored frames."
::= { wanPppStatsEntry 6 }
wanPppStatsOutOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The sum of octets from all frames seen coming from the near
end of the link including errored frames."
::= { wanPppStatsEntry 7 }
wanPppStatsInBadAddresses OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames seen from the far end of the link with
an incorrect address field."
::= { wanPppStatsEntry 8 }
wanPppStatsOutBadAddresses OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames seen from the near end of the link with
an incorrect address field"
::= { wanPppStatsEntry 9 }
wanPppStatsInBadControls OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames seen from the far end of the link with
an incorrect control field."
::= { wanPppStatsEntry 10 }
wanPppStatsOutBadControls OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames seen from the near end of the link with
an incorrect control field."
::= { wanPppStatsEntry 11 }
wanPppStatsInLongFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames seen from the far end of the link that
exceed the MRU."
::= { wanPppStatsEntry 12 }
wanPppStatsOutLongFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames seen from the near end of the link that
exceed the MRU."
::= { wanPppStatsEntry 13 }
wanPppStatsInBadFCSs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets seen from the far end of the link with
incorrect FCSs."
::= { wanPppStatsEntry 14 }
wanPppStatsOutBadFCSs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets seen from the near end of the link with
incorrect FCSs."
::= { wanPppStatsEntry 15 }
wanPppStatsOwner OBJECT-TYPE
SYNTAX OwnerString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The entity that configured this entry."
::= { wanPppStatsEntry 16 }
wanPppStatsStatus OBJECT-TYPE
SYNTAX RowStatus
-- MAX-ACCESS read-write
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this wanPppStatsTable entry."
::= { wanPppStatsEntry 17 }
wanPppHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF WanPppHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"PPP in HDLC service statistics."
::= { wanProtocolHistory 4 }
wanPppHistoryEntry OBJECT-TYPE
SYNTAX WanPppHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The statistics for a PPP in HDLC service. The near end of the
link refers to the side of the link that the probe is
monitoring. The far end is the side the probe is not on."
INDEX { wanPppHistoryIndex, wanPppHistorySampleIndex }
::= { wanPppHistoryTable 1 }
WanPppHistoryEntry ::= SEQUENCE {
wanPppHistoryIndex INTEGER (1..65535),
wanPppHistorySampleIndex INTEGER (1..2147483647),
wanPppHistoryIntervalStart TimeTicks,
wanPppHistoryDropEvents Counter64,
wanPppHistoryInFrames Counter64,
wanPppHistoryOutFrames Counter64,
wanPppHistoryInOctets Counter64,
wanPppHistoryOutOctets Counter64,
wanPppHistoryInBadAddresses Counter64,
wanPppHistoryOutBadAddresses Counter64,
wanPppHistoryInBadControls Counter64,
wanPppHistoryOutBadControls Counter64,
wanPppHistoryInLongFrames Counter64,
wanPppHistoryOutLongFrames Counter64,
wanPppHistoryInBadFCSs Counter64,
wanPppHistoryOutBadFCSs Counter64,
wanPppHistoryInUtilization INTEGER (0..10000),
wanPppHistoryOutUtilization INTEGER (0..10000)
}
wanPppHistoryIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The history of which this entry is a port. The history
identified by a particular value of this index is the same
history as identified by the same value of
historyControlIndex."
::= { wanPppHistoryEntry 1 }
wanPppHistorySampleIndex OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An index that uniquely identifies the particular sample this
entry represents among all samples associated with the same
historyControlEntry. This index starts at 1 and increases
by one as each new sample is taken."
::= {wanPppHistoryEntry 2 }
wanPppHistoryIntervalStart OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime at the start of the interval over which
this sample was measured. If the probe keeps track of time of
day, it should start the first sample of the history at a time
such that when the next hour of the day begins, a sample is
started at that instant. Note that following this rule may
require the probe to delay collection the first sample of the
history, as each sample must be of the same interval. Also
note that the sample which is currently being collected is not
accessible in this table until the end of its interval."
::= { wanPppHistoryEntry 3 }
wanPppHistoryDropEvents OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanPppStatsDropEvents during the
interval."
::= { wanPppHistoryEntry 4 }
wanPppHistoryInFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanPppStatsInFrames during the
interval."
::= { wanPppHistoryEntry 5 }
wanPppHistoryOutFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanPppStatsOutFrames during the
interval."
::= { wanPppHistoryEntry 6 }
wanPppHistoryInOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanPppStatsInOctets during the
interval."
::= { wanPppHistoryEntry 7 }
wanPppHistoryOutOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanPppStatsOutOctets during the
interval."
::= { wanPppHistoryEntry 8 }
wanPppHistoryInBadAddresses OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanPppStatsInBadAddresses during the
interval."
::= { wanPppHistoryEntry 9 }
wanPppHistoryOutBadAddresses OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanPppStatsOutBadAddresses during the
interval."
::= { wanPppHistoryEntry 10 }
wanPppHistoryInBadControls OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanPppStatsInBadControls during the
interval."
::= { wanPppHistoryEntry 11 }
wanPppHistoryOutBadControls OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanPppStatsOutBadControls during the
interval."
::= { wanPppHistoryEntry 12 }
wanPppHistoryInLongFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanPppStatsInLongFrames during the
interval."
::= { wanPppHistoryEntry 13 }
wanPppHistoryOutLongFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanPppStatsOutLongFrames during the
interval."
::= { wanPppHistoryEntry 14 }
wanPppHistoryInBadFCSs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanPppStatsInBadFCSs during the
interval."
::= { wanPppHistoryEntry 15 }
wanPppHistoryOutBadFCSs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanPppStatsOutBadFCSs during the
interval."
::= { wanPppHistoryEntry 16 }
wanPppHistoryInUtilization OBJECT-TYPE
SYNTAX INTEGER (0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The best estimated of the mean physical layer network
utilization of traffic coming from the far end of the
link in hundreds of a percent."
::= { wanPppHistoryEntry 17 }
wanPppHistoryOutUtilization OBJECT-TYPE
SYNTAX INTEGER (0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The best estimated of the mean physical layer network
utilization of traffic coming from the near end of the
link in hundreds of a percent."
::= { wanPppHistoryEntry 18 }
wanX25PvcStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF WanX25PvcStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"X.25 per-LCI statistics for a PVC."
::= { wanPvcStats 1 }
wanX25PvcStatsEntry OBJECT-TYPE
SYNTAX WanX25PvcStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The statistics for a X.25 PVC. The near end of the link
refers to the side of the link that the probe is
monitoring. The far end is the sides the probe is not on."
INDEX { wanX25StatsIndex }
::= { wanX25PvcStatsTable 1 }
WanX25PvcStatsEntry ::= SEQUENCE {
wanX25PvcStatsIndex INTEGER (1..65535),
wanX25PvcStatsDataSource OBJECT IDENTIFIER,
wanX25PvcStatsDropEvents Counter64,
wanX25PvcStatsInFrames Counter64,
wanX25PvcStatsOutFrames Counter64,
wanX25PvcStatsInOctets Counter64,
wanX25PvcStatsOutOctets Counter64,
wanX25PvcStatsInResets Counter64,
wanX25PvcStatsOutResets Counter64,
wanX25PvcStatsProviderResets Counter64,
wanX25PvcStatsInAccusedErrors Counter64,
wanX25PvcStatsOutAccusedErrors Counter64,
wanX25PvcStatsInInterrupts Counter64,
wanX25PvcStatsOutInterrupts Counter64,
wanX25PvcStatsUpTime TimeTicks,
wanX25PvcStatsDownTime TimeTicks,
wanX25PvcStatsState INTEGER,
wanX25PvcStatsStateChanges Counter64,
wanX25PvcStatsOwner OwnerString,
wanX25PvcStatsStatus RowStatus
}
wanX25PvcStatsIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of this object uniquely identifies this
wanX25PvcStatsTable entry."
::= { wanX25PvcStatsEntry 1 }
wanX25PvcStatsDataSource OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object identifies the source of the data that this
wanX25PvcStatsEntry analyzes. This source can be any
pvcEntry associated with an X.25 interface. In order to
identify a particular LCI to monitor, this object shall
identify the instance of the pvcIndex object that
corresponds to a X.25 PVC, defined above for the desired
interface."
::= { wanX25PvcStatsEntry 2 }
wanX25PvcStatsDropEvents OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of events in which frames were dropped by
the probe due to lack of resources. Note that this number
is not necessarily the number of frames dropped; it is just
the number of times this condition has been detected."
::= { wanX25PvcStatsEntry 3 }
wanX25PvcStatsInFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames seen coming from the far end
of the link on this LCI."
::= { wanX25PvcStatsEntry 4 }
wanX25PvcStatsOutFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames seen coming from the near end
of the link on this LCI."
::= { wanX25PvcStatsEntry 5 }
wanX25PvcStatsInOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The sum of octets from all frames seen originating from
the far end of the link on this LCI."
::= { wanX25PvcStatsEntry 6 }
wanX25PvcStatsOutOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The sum of octets from all frames seen originating from
the near end of the link on this LCI."
::= { wanX25PvcStatsEntry 7 }
wanX25PvcStatsInResets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of reset requests seen from the far end of the
link with cause code DTE initiated for this LCI."
::= { wanX25PvcStatsEntry 8 }
wanX25PvcStatsOutResets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of reset requests seen from the far end of the
link with cause code DTE initiated for this LCI."
::= { wanX25PvcStatsEntry 9 }
wanX25PvcStatsProviderResets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of reset requests seen with cause code other
than DTE initiated for this LCI."
::= { wanX25PvcStatsEntry 10 }
wanX25PvcStatsInAccusedErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The numbers of frames seen from the far end of the link
containing a procedure error cause code on this LCI.
These include clear, reset, restart, or diagnostic
packets."
::= { wanX25PvcStatsEntry 11 }
wanX25PvcStatsOutAccusedErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The numbers of frames seen from the near end of the link
containing a procedure error cause code on this LCI.
These include clear, reset, restart, or diagnostic packets."
::= { wanX25PvcStatsEntry 12 }
wanX25PvcStatsInInterrupts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of interrupts frames seen coming from the far
end of the link on this LCI."
::= { wanX25PvcStatsEntry 13 }
wanX25PvcStatsOutInterrupts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of interrupts frames seen coming from the far
end of the link on this LCI."
::= { wanX25PvcStatsEntry 14 }
wanX25PvcStatsUpTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total amount of time in one-hundreds of a second that the
probe is sure this LCI was active, i.e., the total time the
value of wanX25PvcStatsState was equal to up(1). A value of
less than the age of this entry does not necessarily mean that
this LCI was down. It only means the probe was not certain it
was up.
Note: the sum of wanX25PvcStatsUpTime and wanX25PvcStatsDownTime
may be less than the age of this entry. In this case, the
unaccounted for time is the time the probe was uncertain of the
state of this LCI, i.e., the total time the value of
wanX25PvcStatsState was unknown(3)."
::= { wanX25PvcStatsEntry 15 }
wanX25PvcStatsDownTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total amount of time in one-hundreds of a second that the
probe is sure this LCI was down, i.e., the total time the value
of wanX25PvcStatsState was equal to down(3). A value of less
than the age of this entry does not necessarily mean that this
LCI was up at some point. It only means the probe was not
certain it was down.
Note: the sum of wanX25PvcStatsUpTime and wanX25PvcStatsDownTime
may be less than the age of this entry. In this case, the
unaccounted for time is the time the probe was uncertain of the
state of this LCI, i.e., the total time the value of
wanX25PvcStatsState was unknown(3)."
::= { wanX25PvcStatsEntry 16 }
wanX25PvcStatsState OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2),
unknown(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current state of this LCI as inferred by the probe.
A value of up(2) means the LCI is active. A value of
down(2) means the LCI is inactive. And a value of
unknown(3) means the probe cannot currently infer the
state."
::= { wanX25PvcStatsEntry 17 }
wanX25PvcStatsStateChanges OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The count of the number of times the wanX25PvcStatsState
has gone from up(1) to down(2) or vice versa. The number
of times wanX25PvcStatsState goes to unknown(3) is not
counted. However, if the value goes from up(1) to unknown(3)
and then to down(2) should be counted as 1. Likewise going
from down(2) to unknown(3) and then to up(3) should be
counted as 1."
::= { wanX25PvcStatsEntry 18 }
wanX25PvcStatsOwner OBJECT-TYPE
SYNTAX OwnerString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The entity that configured this entry."
::= { wanX25PvcStatsEntry 19 }
wanX25PvcStatsStatus OBJECT-TYPE
SYNTAX RowStatus
-- MAX-ACCESS read-write
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this wanX25PvcStatsTable entry."
::= { wanX25PvcStatsEntry 20 }
wanX25PvcHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF WanX25PvcHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"X.25 per LCI statistics."
::= { wanPvcHistory 1 }
wanX25PvcHistoryEntry OBJECT-TYPE
SYNTAX WanX25PvcHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The statistics for a X.25 LCI. The near end of the link
refers to the side of the link that the probe is monitoring.
The far end is the side the probe is not on."
INDEX { wanX25PvcHistoryIndex, wanX25PvcHistorySampleIndex }
::= { wanX25PvcHistoryTable 1 }
WanX25PvcHistoryEntry ::= SEQUENCE {
wanX25PvcHistoryIndex INTEGER (1..65535),
wanX25PvcHistorySampleIndex INTEGER (1..2147483647),
wanX25PvcHistoryIntervalStart TimeTicks,
wanX25PvcHistoryDropEvents Counter64,
wanX25PvcHistoryInFrames Counter64,
wanX25PvcHistoryOutFrames Counter64,
wanX25PvcHistoryInOctets Counter64,
wanX25PvcHistoryOutOctets Counter64,
wanX25PvcHistoryInResets Counter64,
wanX25PvcHistoryOutResets Counter64,
wanX25PvcHistoryProviderResets Counter64,
wanX25PvcHistoryInAccusedErrors Counter64,
wanX25PvcHistoryOutAccusedErrors Counter64,
wanX25PvcHistoryInInterrupts Counter64,
wanX25PvcHistoryOutInterrupts Counter64,
wanX25PvcHistoryUpTime TimeTicks,
wanX25PvcHistoryDownTime TimeTicks,
wanX25PvcHistoryStateChanges Counter64,
wanX25PvcHistoryInUtilization INTEGER (0..10000),
wanX25PvcHistoryOutUtilization INTEGER (0..10000)
}
wanX25PvcHistoryIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The history of which this entry is a port. The history
identified by a particular value of this index is the
same history as identified by the same value of
historyControlIndex."
::= { wanX25PvcHistoryEntry 1 }
wanX25PvcHistorySampleIndex OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An index that uniquely identifies the particular sample this
entry represents among all samples associated with the same
historyControlEntry. This index starts at 1 and increases by
one as each new sample is taken."
::= {wanX25PvcHistoryEntry 2 }
wanX25PvcHistoryIntervalStart OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime at the start of the interval over
which this sample was measured. If the probe keeps track
of time of day, it should start the first sample of the
history at a time such that when the next hour of the day
begins, a sample is started at that instant. Note that
following this rule may require the probe to delay collection
the first sample of the history, as each sample must be of the
same interval. Also note that the sample which is currently
being collected is not accessible in this table until the end
of its interval."
::= { wanX25PvcHistoryEntry 3 }
wanX25PvcHistoryDropEvents OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanX25PvcStatsDropEvents during the
interval."
::= { wanX25PvcHistoryEntry 4 }
wanX25PvcHistoryInFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanX25PvcStatsInFrames during the
interval."
::= { wanX25PvcHistoryEntry 5 }
wanX25PvcHistoryOutFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanX25PvcStatsOutFrames during the
interval."
::= { wanX25PvcHistoryEntry 6 }
wanX25PvcHistoryInOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanX25PvcStatsInOctets during the
interval."
::= { wanX25PvcHistoryEntry 7 }
wanX25PvcHistoryOutOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanX25PvcStatsOutOctets during the
interval."
::= { wanX25PvcHistoryEntry 8 }
wanX25PvcHistoryInResets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanX25PvcStatsInResets during the
interval."
::= { wanX25PvcHistoryEntry 9 }
wanX25PvcHistoryOutResets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanX25PvcStatsOutResets during the
interval."
::= { wanX25PvcHistoryEntry 10 }
wanX25PvcHistoryProviderResets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanX25PvcStatsProviderResets during the
interval."
::= { wanX25PvcHistoryEntry 11 }
wanX25PvcHistoryInAccusedErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanX25PvcStatsInAccusedErrors during the
interval."
::= { wanX25PvcHistoryEntry 12 }
wanX25PvcHistoryOutAccusedErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanX25PvcStatsOutAccusedErrors during the
interval."
::= { wanX25PvcHistoryEntry 13 }
wanX25PvcHistoryInInterrupts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanX25PvcStatsInInterrupts during the
interval."
::= { wanX25PvcHistoryEntry 14 }
wanX25PvcHistoryOutInterrupts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanX25PvcStatsOutInterrupts during the
interval."
::= { wanX25PvcHistoryEntry 15 }
wanX25PvcHistoryUpTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanX25PvcStatsUpTime during the
interval."
::= { wanX25PvcHistoryEntry 16 }
wanX25PvcHistoryDownTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanX25PvcStatsDownTime during the
interval."
::= { wanX25PvcHistoryEntry 17 }
wanX25PvcHistoryStateChanges OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanX25PvcStatsStateChanges during the
interval."
::= { wanX25PvcHistoryEntry 18 }
wanX25PvcHistoryInUtilization OBJECT-TYPE
SYNTAX INTEGER (0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The best estimated of the mean utilization of traffic on this
LCI coming from the far end of the link in hundreds of percent
of the CIR."
::= { wanX25PvcHistoryEntry 19 }
wanX25PvcHistoryOutUtilization OBJECT-TYPE
SYNTAX INTEGER (0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The best estimated of the mean utilization of traffic on this
LCI coming from the near end of the link in hundreds of percent
of CIR."
::= { wanX25PvcHistoryEntry 20 }
wanFrPvcStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF WanFrPvcStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Frame Relay per-DLCI statistics."
::= { wanPvcStats 2 }
wanFrPvcStatsEntry OBJECT-TYPE
SYNTAX WanFrPvcStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The statistics for a frame relay DLCI. The near end of the
link refers to the side of the link that the probe is
monitoring. The far end is the side the probe is not on."
INDEX { wanFrPvcStatsIndex }
::= { wanFrPvcStatsTable 1 }
WanFrPvcStatsEntry ::= SEQUENCE {
wanFrPvcStatsIndex INTEGER (1..65535),
wanFrPvcStatsDataSource OBJECT IDENTIFIER,
wanFrPvcStatsDropEvents Counter64,
wanFrPvcStatsInFrames Counter64,
wanFrPvcStatsOutFrames Counter64,
wanFrPvcStatsInOctets Counter64,
wanFrPvcStatsOutOctets Counter64,
wanFrPvcStatsInFECNs Counter64,
wanFrPvcStatsOutFECNs Counter64,
wanFrPvcStatsInBECNs Counter64,
wanFrPvcStatsOutBECNs Counter64,
wanFrPvcStatsInDEs Counter64,
wanFrPvcStatsOutDEs Counter64,
wanFrPvcStatsUpTime TimeTicks,
wanFrPvcStatsDownTime TimeTicks,
wanFrPvcStatsState INTEGER,
wanFrPvcStatsStateChanges Counter64,
wanFrPvcStatsOwner OwnerString,
wanFrPvcStatsStatus RowStatus
}
wanFrPvcStatsIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of this object uniquely identifies this
wanFrPvcStatsTable entry."
::= { wanFrPvcStatsEntry 1 }
wanFrPvcStatsDataSource OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object identifies the source of the data that this
wanFrPvcStatsEntry analyzes. This source can be any
pvcEntry associated with a frame relay interface on this
device. In order to identify a particular DLCI, this object
shall identify the instance of the frame relay pvcIndex
object, defined in the PVCCONFIG-MIB."
::= {wanFrPvcStatsEntry 2 }
wanFrPvcStatsDropEvents OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of events in which frames were dropped by
the probe due to lack of resources. Note that this number is
not necessarily the number of frames dropped; it is just the
number of times this condition has been detected."
::= { wanFrPvcStatsEntry 3 }
wanFrPvcStatsInFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames seen coming from the far end of
the link on this DLCI."
::= { wanFrPvcStatsEntry 4 }
wanFrPvcStatsOutFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames seen coming from the near end of
the link on this DLCI."
::= { wanFrPvcStatsEntry 5 }
wanFrPvcStatsInOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The sum of octets from all frames seen originating from the
far end of the link on this DLCI."
::= { wanFrPvcStatsEntry 6 }
wanFrPvcStatsOutOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The sum of octets from all frames seen originating from the
near end of the link on this DLCI."
::= { wanFrPvcStatsEntry 7 }
wanFrPvcStatsInFECNs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames see coming form the far end of the link
with the FECN bit set on this DLCI."
::= { wanFrPvcStatsEntry 8 }
wanFrPvcStatsOutFECNs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames seen coming from the far end of the
link with the BECN bit set on this DLCI."
::= { wanFrPvcStatsEntry 9 }
wanFrPvcStatsInBECNs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames see coming form the near end of the
link with the FECN bit set."
::= { wanFrPvcStatsEntry 10 }
wanFrPvcStatsOutBECNs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames seen coming from the near end of the
link with the BECN bit set on this DLCI."
::= { wanFrPvcStatsEntry 11 }
wanFrPvcStatsInDEs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames seen coming from the far end of the
link with the DE bit set on this DCLI."
::= { wanFrPvcStatsEntry 12 }
wanFrPvcStatsOutDEs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames seen coming from the near end of the
link with the DE bit set on this DLCI."
::= { wanFrPvcStatsEntry 13 }
wanFrPvcStatsUpTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total amount of time in one-hundreds of a second that
the probe is sure this LCI was active, i.e., the total time
the value of wanFrPvcStatsState was equal to up(1). A value
of less than the age of this entry does not necessarily mean
that this LCI was down. It only means the probe was not
certain it was up.
Note: the sum of wanFrPvcStatsUpTime and wanFrPvcStatsDownTime
may be less than the age of this entry. In this case, the
unaccounted for time is the time the probe was uncertain of the
state of this DLCI, i.e., the total time the value of
wanFrPvcStatsState was unknown(3)."
::= { wanFrPvcStatsEntry 14 }
wanFrPvcStatsDownTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total amount of time in one-hundreds of a second that
the probe is sure this LCI was down, i.e., the total time
the value of wanFrPvcStatsState was equal to down(3). A
value of less than the age of this entry does not
necessarily mean that this LCI was up at some point. It
only means the probe was not certain it was down.
Note: the sum of wanX25PvcStatsUpTime and wanFrPvcStatsDownTime
may be less than the age of this entry. In this case, the
unaccounted for time is the time the probe was uncertain of the
state of this DLCI, i.e., the total time the value of
wanFrPvcStatsState was unknown(3)."
::= { wanFrPvcStatsEntry 15 }
wanFrPvcStatsState OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2),
unknown(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current state of this DLCI as inferred by the probe.
A value of up(2) means the DLCI is active. A value of down(2)
means the DLCI is inactive. And a value of unknown(3) means
the probe cannot currently infer the state."
::= { wanFrPvcStatsEntry 16 }
wanFrPvcStatsStateChanges OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The count of the number of times the wanFrPvcStatsState has
gone from up(1) to down(2) or vice versa. The number of
times wanFrPvcStatsState goes to unknown(3) is not counted.
However, if the value goes from up(1) to unknown(3) and then
to down(2) should be counted as 1. Likewise going from down(2)
to unknown(3) and then to up(3) should be counted as 1."
::= { wanFrPvcStatsEntry 17 }
wanFrPvcStatsOwner OBJECT-TYPE
SYNTAX OwnerString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The entity that configured this entry."
::= { wanFrPvcStatsEntry 18 }
wanFrPvcStatsStatus OBJECT-TYPE
SYNTAX RowStatus
-- MAX-ACCESS read-write
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this wanFrPvcStatsTable entry."
::= { wanFrPvcStatsEntry 19 }
wanFrPvcHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF WanFrPvcHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Frame Relay per-DCLI statistics."
::= { wanPvcHistory 2 }
wanFrPvcHistoryEntry OBJECT-TYPE
SYNTAX WanFrPvcHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The statistics for a frame relay DLCI. The near end of the
link refers to the side of the link that the probe is
monitoring. The far end is the side the probe is not on."
INDEX { wanFrPvcHistoryIndex, wanFrPvcHistorySampleIndex }
::= { wanFrPvcHistoryTable 1 }
WanFrPvcHistoryEntry ::= SEQUENCE {
wanFrPvcHistoryIndex INTEGER (1..65535),
wanFrPvcHistorySampleIndex INTEGER (1..2147483647),
wanFrPvcHistoryIntervalStart TimeTicks,
wanFrPvcHistoryDropEvents Counter64,
wanFrPvcHistoryInFrames Counter64,
wanFrPvcHistoryOutFrames Counter64,
wanFrPvcHistoryInOctets Counter64,
wanFrPvcHistoryOutOctets Counter64,
wanFrPvcHistoryInFECNs Counter64,
wanFrPvcHistoryOutFECNs Counter64,
wanFrPvcHistoryInBECNs Counter64,
wanFrPvcHistoryOutBECNs Counter64,
wanFrPvcHistoryInDEs Counter64,
wanFrPvcHistoryOutDEs Counter64,
wanFrPvcHistoryUpTime TimeTicks,
wanFrPvcHistoryDownTime TimeTicks,
wanFrPvcHistoryStateChanges Counter64,
wanFrPvcHistoryInUtilization INTEGER (0..10000),
wanFrPvcHistoryOutUtilization INTEGER (0..10000)
}
wanFrPvcHistoryIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The history of which this entry is a port. The history
identified by a particular value of this index is the same
history as identified by the same value of historyControlIndex."
::= { wanFrPvcHistoryEntry 1 }
wanFrPvcHistorySampleIndex OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An index that uniquely identifies the particular sample this
entry represents among all samples associated with the same
historyControlEntry. This index starts at 1 and increases by
one as each new sample is taken."
::= { wanFrPvcHistoryEntry 2 }
wanFrPvcHistoryIntervalStart OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime at the start of the interval over
which this sample was measured. If the probe keeps track
of time of day, it should start the first sample of the
history at a time such that when the next hour of the day
begins, a sample is started at that instant. Note that
following this rule may require the probe to delay collection
the first sample of the history, as each sample must be of the
same interval. Also note that the sample which is currently
being collected is not accessible in this table until the end
of its interval."
::= { wanFrPvcHistoryEntry 3 }
wanFrPvcHistoryDropEvents OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanFrPvcStatsDropEvents during the
interval."
::= { wanFrPvcHistoryEntry 4 }
wanFrPvcHistoryInFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanFrPvcStatsInFrames during the
interval."
::= { wanFrPvcHistoryEntry 5 }
wanFrPvcHistoryOutFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanFrPvcStatsOutFrames during the
interval."
::= { wanFrPvcHistoryEntry 6 }
wanFrPvcHistoryInOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanFrPvcStatsInOctets during the
interval."
::= { wanFrPvcHistoryEntry 7 }
wanFrPvcHistoryOutOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanFrPvcStatsOutOctets during the
interval."
::= { wanFrPvcHistoryEntry 8 }
wanFrPvcHistoryInFECNs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanFrPvcStatsInFECNs during the
interval."
::= { wanFrPvcHistoryEntry 9 }
wanFrPvcHistoryOutFECNs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanFrPvcStatsOutFECNs during the
interval."
::= { wanFrPvcHistoryEntry 10 }
wanFrPvcHistoryInBECNs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanFrPvcStatsInBECNs during the
interval."
::= { wanFrPvcHistoryEntry 11 }
wanFrPvcHistoryOutBECNs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanFrPvcStatsOutBECNs during the
interval."
::= { wanFrPvcHistoryEntry 12 }
wanFrPvcHistoryInDEs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanFrPvcStatsInDEs during the
interval."
::= { wanFrPvcHistoryEntry 13 }
wanFrPvcHistoryOutDEs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanFrPvcStatsOutDEs during the
interval."
::= { wanFrPvcHistoryEntry 14 }
wanFrPvcHistoryUpTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanFrPvcStatsUpTime during the
interval."
::= { wanFrPvcHistoryEntry 15 }
wanFrPvcHistoryDownTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanFrPvcStatsDownTime during the
interval."
::= { wanFrPvcHistoryEntry 16 }
wanFrPvcHistoryStateChanges OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanFrPvcStatsStateChanges during the
interval."
::= { wanFrPvcHistoryEntry 17 }
wanFrPvcHistoryInUtilization OBJECT-TYPE
SYNTAX INTEGER (0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The best estimated of the mean utilization of traffic on
this DLCI coming from the far end of the link in hundreds
of percent of the CIR."
::= { wanFrPvcHistoryEntry 18 }
wanFrPvcHistoryOutUtilization OBJECT-TYPE
SYNTAX INTEGER (0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The best estimated of the mean utilization of traffic on
this DLCI coming from the near end of the link in hundreds
of percent of CIR."
::= { wanFrPvcHistoryEntry 19 }
wanAal5PvcStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF WanAal5PvcStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"AAL/5 per-VPI/VCI statistics."
::= { wanPvcStats 3 }
wanAal5PvcStatsEntry OBJECT-TYPE
SYNTAX WanAal5PvcStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The statistics for a AAL-5 VCI/VPI. The near end of the
link refers to the side of the link that the probe is
monitoring. The far end is the side the probe is not on."
INDEX { wanAal5PvcStatsIndex }
::= { wanAal5PvcStatsTable 1 }
WanAal5PvcStatsEntry ::= SEQUENCE {
wanAal5PvcStatsIndex INTEGER (1..65535),
wanAal5PvcStatsDataSource OBJECT IDENTIFIER,
wanAal5PvcStatsDropEvents Counter64,
wanAal5PvcStatsInCells Counter64,
wanAal5PvcStatsOutCells Counter64,
wanAal5PvcStatsInPDUs Counter64,
wanAal5PvcStatsOutPDUs Counter64,
wanAal5PvcStatsInOctets Counter64,
wanAal5PvcStatsOutOctets Counter64,
wanAal5PvcStatsInCLP1 Counter64,
wanAal5PvcStatsOutCLP1 Counter64,
wanAal5PvcStatsInCRCs Counter64,
wanAal5PvcStatsOutCRCs Counter64,
wanAal5PvcStatsInOversizedSDUs Counter64,
wanAal5PvcStatsOutOversizedSDUs Counter64,
wanAal5PvcStatsUpTime TimeTicks,
wanAal5PvcStatsDownTime TimeTicks,
wanAal5PvcStatsState INTEGER,
wanAal5PvcStatsStateChanges Counter64,
wanAal5PvcStatsOwner OwnerString,
wanAal5PvcStatsStatus RowStatus
}
wanAal5PvcStatsIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of this object uniquely identifies this
wanAal5PvcStatsTable entry."
::= { wanAal5PvcStatsEntry 1 }
wanAal5PvcStatsDataSource OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object identifies the source of the data that this
wanAal5StatsEntry analyzes. This source can be any
pvcEntry that is associated with an ATM interface on this
device. In order to identify a particular VPI/VCI, this
object shall identify the instance of the pvcIndex object,
defined in the PVCCONFIG-MIB."
::= { wanAal5PvcStatsEntry 2 }
wanAal5PvcStatsDropEvents OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of events in which frames were dropped
by the probe due to lack of resources. Note that this
number is not necessarily the number of frames dropped;
it is just the number of times this condition has been
detected."
::= { wanAal5PvcStatsEntry 3 }
wanAal5PvcStatsInCells OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of cells for seen coming from the far
end of the link on this VPI/VCI."
::= { wanAal5PvcStatsEntry 4 }
wanAal5PvcStatsOutCells OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of cells seen coming from the near end
of the link on this VPI/VCI."
::= { wanAal5PvcStatsEntry 5 }
wanAal5PvcStatsInPDUs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of AAL-5 PDUs seen coming from the far
end of the link on this VPI/VCI."
::= { wanAal5PvcStatsEntry 6 }
wanAal5PvcStatsOutPDUs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of AAL-5 PDUs seen coming from the near
end of the link on this VPI/VCI."
::= { wanAal5PvcStatsEntry 7 }
wanAal5PvcStatsInOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The sum of octets from all AAL-5 PDUs seen originating from
the far end of the link on this VCI/VPI."
::= { wanAal5PvcStatsEntry 8 }
wanAal5PvcStatsOutOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The sum of octets from all AAL-5 PDUs seen originating from
the near end of the link on this VPI/VCI."
::= { wanAal5PvcStatsEntry 9 }
wanAal5PvcStatsInCLP1 OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of cells with the CLP bit set seen coming
from the far end of the link on this VCI/VPI."
::= { wanAal5PvcStatsEntry 10 }
wanAal5PvcStatsOutCLP1 OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of cells with the CLP bit set seen coming
from the near end of the link on this VCI/VPI."
::= { wanAal5PvcStatsEntry 11 }
wanAal5PvcStatsInCRCs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of AAL-5 PDUs with CRC errors seen coming
from the far end of the link on this VCI/VPI."
::= { wanAal5PvcStatsEntry 12 }
wanAal5PvcStatsOutCRCs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of AAL-5 PDUs with CRC errors seen coming
from the near end of the link on this VPI/VCI."
::= { wanAal5PvcStatsEntry 13 }
wanAal5PvcStatsInOversizedSDUs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of AAL5 SDUs from the far end of the link that
were too large on this VPI/VCI."
::= { wanAal5PvcStatsEntry 14 }
wanAal5PvcStatsOutOversizedSDUs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of AAL5 SDUs from the near end of the link that
were too large on this VPI/VCI."
::= { wanAal5PvcStatsEntry 15 }
wanAal5PvcStatsUpTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total amount of time in one-hundreds of a second that
the probe is sure this LCI was active, i.e., the total time
the value of wanAal5PvcStatsState was equal to up(1). A value
of less than the age of this entry does not necessarily mean
that this VPI/VCI was down. It only means the probe was not
certain it was up.
Note: the sum of wanAal5PvcStatsUpTime and
wanAal5PvcStatsDownTime may be less than the age of this entry.
In this case, the unaccounted for time is the time the probe was
uncertain of the state of this VPI/VCI, i.e., the total time the
value of wanAal5PvcStatsState was unknown(3)."
::= { wanAal5PvcStatsEntry 16 }
wanAal5PvcStatsDownTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total amount of time in one-hundreds of a second that the
probe is sure this LCI was down, i.e., the total time the
value of wanAal5PvcStatsState was equal to down(3). A value of
less than the age of this entry does not necessarily mean that
this VPI/VCI was up at some point. It only means the probe was
not certain it was down.
Note: the sum of wanAal5PvcStatsUpTime and
wanAal5PvcStatsDownTime may be less than the age of this entry.
In this case, the unaccounted for time is the time the probe was
uncertain of the state of this VPI/VCI, i.e., the total time the
value of wanAal5PvcStatsState was unknown(3)."
::= { wanAal5PvcStatsEntry 17 }
wanAal5PvcStatsState OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2),
unknown(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current state of this VPI/VCI as inferred by the probe.
A value of up(2) means the LCI is active. A value of down(2)
means the VPI/VCI is inactive. And a value of unknown(3)
means the probe cannot currently infer the state."
::= { wanAal5PvcStatsEntry 18 }
wanAal5PvcStatsStateChanges OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The count of the number of times the wanAal5PvcStatsState
has gone from up(1) to down(2) or vice versa. The number of
times wanAal5PvcStatsState goes to unknown(3) is not counted.
However, if the value goes from up(1) to unknown(3) and then
to down(2) should be counted as 1. Likewise going from down(2)
to unknown(3) and then to up(3) should be counted as 1."
::= { wanAal5PvcStatsEntry 19 }
wanAal5PvcStatsOwner OBJECT-TYPE
SYNTAX OwnerString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The entity that configured this entry."
::= { wanAal5PvcStatsEntry 20 }
wanAal5PvcStatsStatus OBJECT-TYPE
SYNTAX RowStatus
-- MAX-ACCESS read-write
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this wanAal5PvcStatsTable entry."
::= { wanAal5PvcStatsEntry 21 }
wanAal5PvcHistoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF WanAal5PvcHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"AAL-5 per-VPI/VCI statistics."
::= { wanPvcHistory 3 }
wanAal5PvcHistoryEntry OBJECT-TYPE
SYNTAX WanAal5PvcHistoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The statistics for a AAL-5 VCI/VPI. The near end of the link
refers to the side of the link that the probe is monitoring.
The far end is the side the probe is not on."
INDEX { wanAal5PvcHistoryIndex, wanAal5PvcHistorySampleIndex }
::= { wanAal5PvcHistoryTable 1 }
WanAal5PvcHistoryEntry ::= SEQUENCE {
wanAal5PvcHistoryIndex INTEGER (1..65535),
wanAal5PvcHistorySampleIndex INTEGER (1..2147483647),
wanAal5PvcHistoryIntervalStart TimeTicks,
wanAal5PvcHistoryDropEvents Counter64,
wanAal5PvcHistoryInCells Counter64,
wanAal5PvcHistoryOutCells Counter64,
wanAal5PvcHistoryInPDUs Counter64,
wanAal5PvcHistoryOutPDUs Counter64,
wanAal5PvcHistoryInOctets Counter64,
wanAal5PvcHistoryOutOctets Counter64,
wanAal5PvcHistoryInCLP1 Counter64,
wanAal5PvcHistoryOutCLP1 Counter64,
wanAal5PvcHistoryInCRCs Counter64,
wanAal5PvcHistoryOutCRCs Counter64,
wanAal5PvcHistoryInOversizedSDUs Counter64,
wanAal5PvcHistoryOutOversizedSDUs Counter64,
wanAal5PvcHistoryUpTime TimeTicks,
wanAal5PvcHistoryDownTime TimeTicks,
wanAal5PvcHistoryStateChanges Counter64,
wanAal5PvcHistoryInUtilization INTEGER (0..10000),
wanAal5PvcHistoryOutUtilization INTEGER (0..10000)
}
wanAal5PvcHistoryIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The history of which this entry is a port. The history
identified by a particular value of this index is the same
history as identified by the same value of
historyControlIndex."
::= { wanAal5PvcHistoryEntry 1 }
wanAal5PvcHistorySampleIndex OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An index that uniquely identifies the particular sample
this entry represents among all samples associated with
the same historyControlEntry. This index starts at 1 and
increases by one as each new sample is taken."
::= {wanAal5PvcHistoryEntry 2 }
wanAal5PvcHistoryIntervalStart OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime at the start of the interval over
which this sample was measured. If the probe keeps track
of time of day, it should start the first sample of the
history at a time such that when the next hour of the day
begins, a sample is started at that instant. Note that
following this rule may require the probe to delay collection
the first sample of the history, as each sample must be of the
same interval. Also note that the sample which is currently
being collected is not accessible in this table until the end
of its interval."
::= { wanAal5PvcHistoryEntry 3 }
wanAal5PvcHistoryDropEvents OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAal5PvcStatsDropEvents during the
interval."
::= { wanAal5PvcHistoryEntry 4 }
wanAal5PvcHistoryInCells OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAal5PvcStatsInCells during the
interval."
::= { wanAal5PvcHistoryEntry 5 }
wanAal5PvcHistoryOutCells OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAal5PvcStatsOutCells during the
interval."
::= { wanAal5PvcHistoryEntry 6 }
wanAal5PvcHistoryInPDUs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAal5PvcStatsInPDUs during the
interval."
::= { wanAal5PvcHistoryEntry 7 }
wanAal5PvcHistoryOutPDUs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAal5PvcStatsOutPDUs during the
interval."
::= { wanAal5PvcHistoryEntry 8 }
wanAal5PvcHistoryInOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAal5PvcStatsInOctets during the
interval."
::= { wanAal5PvcHistoryEntry 9 }
wanAal5PvcHistoryOutOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAal5PvcStatsOutOctets during the
interval."
::= { wanAal5PvcHistoryEntry 10 }
wanAal5PvcHistoryInCLP1 OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAal5PvcStatsInCLP1 during the
interval."
::= { wanAal5PvcHistoryEntry 11 }
wanAal5PvcHistoryOutCLP1 OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAal5PvcStatsOutCLP1 during the
interval."
::= { wanAal5PvcHistoryEntry 12 }
wanAal5PvcHistoryInCRCs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAal5PvcStatsInCRCs during the
interval."
::= { wanAal5PvcHistoryEntry 13 }
wanAal5PvcHistoryOutCRCs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAal5PvcStatsOutCRCs during the
interval."
::= { wanAal5PvcHistoryEntry 14 }
wanAal5PvcHistoryInOversizedSDUs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAal5PvcStatsInOversizedSDUs
during the interval."
::= { wanAal5PvcHistoryEntry 15 }
wanAal5PvcHistoryOutOversizedSDUs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAal5PvcStatsOutOversizedSDUs
during the interval."
::= { wanAal5PvcHistoryEntry 16 }
wanAal5PvcHistoryUpTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAal5PvcStatsUpTime
during the interval."
::= { wanAal5PvcHistoryEntry 17 }
wanAal5PvcHistoryDownTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAal5PvcStatsDownTime
during the interval."
::= { wanAal5PvcHistoryEntry 18 }
wanAal5PvcHistoryStateChanges OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The change in value of wanAal5PvcStatsStateChanges
during the interval."
::= { wanAal5PvcHistoryEntry 19 }
wanAal5PvcHistoryInUtilization OBJECT-TYPE
SYNTAX INTEGER (0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The best estimated of the mean utilization of traffic on
this VPI/VCI coming from the far end of the link in hundreds
of percent of the CIR."
::= { wanAal5PvcHistoryEntry 20 }
wanAal5PvcHistoryOutUtilization OBJECT-TYPE
SYNTAX INTEGER (0..10000)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The best estimated of the mean utilization of traffic on
this VPI/VCI coming from the near end of the link in hundreds
of percent of CIR."
::= { wanAal5PvcHistoryEntry 21 }
END