librenms/mibs/telco-systems/binos/PRVT-CONFIGCHANGE-MIB
Tony Murray 11147d3bbf
Major Processors rewrite (#8066)
* Extract DiscoveryItem and move some things to better places.
Extract model class
Fix up model construction.  I have problem with construction...
Makeshift model working.  Switch constructor to factory.  discover() and create()
Support legacy discovery.
Remove uneeded custom pollers
Remove netonix custom detection as we try ucd on all os now.
Add a few yaml procs.  Fix a couple things.
More processor discovery conversions
Move Calix e7 to standard hrProcessorLoad, but it doesn't fully implement the HR-MIB, move things around to make it work.
Add a few yaml procs.  Fix a couple things. Correct some stupid mib stuff.
Move more, drop php 5.3
Add netscaler which uses string indexes.  Port fiberhome to yaml and use skip_values
More conversions.  BroadcomProcessorUsage Trait
Serveriron and Ironware share some mibs.  Create a common abstract os for them.
Add yaml support for mib specification in each data entry
Make legacy discover_processor() set 0 for hrDeviceIndex

Untangle Dell switch OS processors

Use use shared OS for groups if they don't have a specific group.
fix silly mib mistake

Make index optional

Move HR and UCD to Traits and out of Processor.

* forgot to update the fortiswitch index

* Make sgos and avaya-ers match the old index.

* fix comware test data

* fix merge errors

* fix dsm and remove pointless empty modules

* file not found exception is in the wrong place.

* Updated processor development docs
2018-02-05 07:39:13 -06:00

159 lines
5.2 KiB
Plaintext
Raw Blame History

This file contains invisible Unicode characters

This file contains invisible Unicode characters that are indistinguishable to humans but may be processed differently by a computer. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.

-- *********************************************************************
-- *********************************************************************
-- ** Filename: PRVT-CONFIGCHANGE-MIB
-- ** Project: T - Ethernet and Fast Ethernet IP Switches.
-- ** Purpose: Private MIB
-- *********************************************************************
-- (c) Copyright, 2001, BATM Advanced Communications. All rights reserved.
-- WARNING:
--
-- BY UTILIZING THIS FILE, YOU AGREE TO THE FOLLOWING:
--
-- This file is the property of BATM Advanced Communications.
-- BATM Advanced Communications retains all title and
-- ownership in the Specification, including any revisions.
-- BATM Advanced Communications grants all interested parties a non-exclusive
-- license to use and distribute an unmodified copy of this
-- Specification in connection with management of BATM Advanced Communications
-- and Telco Systems products, and without fee, provided that the following
-- conditions are met:
-- 1. Redistributions of this specification must retain the above copyright
-- notice, this list of conditions and the following disclaimer.
-- 2. Redistributions in binary form must reproduce the above copyright
-- notice, this list of conditions and the following disclaimer in the
-- documentation and/or other materials provided with the distribution.
-- 3. The name of the BATM Advanced Communications MAY NOT be used to endorse
-- or promote products derived from this specification without specific prior written
-- permission.
--
-- EXCEPT AS RESTRICTED BY LAW, OR AS PROVIDED IN BATM'S LIMITED
-- WARRANTY, THE SPECIFICATIONS CONTAINED IN THIS FILE ARE
-- PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED
-- OR IMPLIED, INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES
-- OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
-- IN NO EVENT SHALL BATM BE LIABLE FOR ANY DAMAGES WHATSOEVER
-- INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS
-- PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR
-- OTHER CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE, OR INABILITY
-- TO USE, THE SPECIFICATION CONTAINED IN THIS FILE.
PRVT-CONFIGCHANGE-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
NOTIFICATION-TYPE
FROM SNMPv2-SMI
RowPointer,
DisplayString
FROM SNMPv2-TC
switch
FROM PRVT-SWITCH-MIB;
prvtConfigChangeMIB MODULE-IDENTITY
LAST-UPDATED "200907130000Z"
ORGANIZATION "BATM Advanced Communication"
CONTACT-INFO
"BATM/Telco Systems Support team
Email:
For North America: techsupport@telco.com
For North Europe: support@batm.de, info@batm.de
For the rest of the world: techsupport@telco.com"
DESCRIPTION
"Initial version. This MIB will provied traps for change"
-- Revision history.
REVISION "200907130000Z"
DESCRIPTION
"Add object snmpServerStatus and notification snmpServerStatusChange"
REVISION "200611200000Z"
DESCRIPTION
"Initial release"
::= { switch 150 }
prvtConfigChangeAlarmOID OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The configChangeAlarmOID specifies the OID of an object whose value has been changed."
::= {prvtConfigChangeObjects 1}
prvtConfigChangeAlarmRow OBJECT-TYPE
SYNTAX RowPointer
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"The configChangeAlarmRow specifies the OID of the row from table, whose entry has been changed."
::= {prvtConfigChangeObjects 2}
cliConfigChangeNodePrompt OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Shows the CLI prompt."
::= {prvtConfigChangeObjects 3}
cliConfigChangeCommand OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Shows executed command."
::= {prvtConfigChangeObjects 4}
snmpServerStatus OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Shows the enabled/disabled status of the SNMP server."
::= {prvtConfigChangeObjects 5}
prvtConfigChangeAlarm NOTIFICATION-TYPE
OBJECTS {prvtConfigChangeAlarmOID, prvtConfigChangeAlarmRow}
STATUS current
DESCRIPTION
"This notification is generated when the value of configurable
attribute has been changed. The notification can be used
to trigger maintenance polling of the running configuration
on the device. One of the varbinds will point either to entry
of the modified table (configChangeAlarmRow) or the
OID of the modified scalar object "
::= { prvtConfigChangeNotifications 1}
cliConfigurationChange NOTIFICATION-TYPE
OBJECTS {cliConfigChangeNodePrompt,cliConfigChangeCommand}
STATUS current
DESCRIPTION
"This notification is generated when command in configuration node is executed."
::= { prvtConfigChangeNotifications 2}
snmpServerStatusChange NOTIFICATION-TYPE
OBJECTS {
snmpServerStatus
}
STATUS current
DESCRIPTION
"The notification shall be sent whenever the enabled/disabled status
of the SNMP server changes. If the status is changed
from enabled to disabled, the notification shall be sent
prior to disabling the SNMP server."
::= {prvtConfigChangeNotifications 3}
prvtConfigChangeNotifications OBJECT IDENTIFIER ::= { prvtConfigChangeMIB 0 }
prvtConfigChangeObjects OBJECT IDENTIFIER ::= { prvtConfigChangeMIB 1 }
prvtConfigChangeConformance OBJECT IDENTIFIER ::= { prvtConfigChangeMIB 3 }
END