librenms/mibs/Dell_vendor.mib

438 lines
15 KiB
Plaintext

Dell-Vendor-MIB DEFINITIONS ::= BEGIN
IMPORTS
enterprises, TimeTicks
FROM RFC1155-SMI
MODULE-IDENTITY, OBJECT-TYPE, Unsigned32, Integer32, IpAddress,
NOTIFICATION-TYPE
FROM SNMPv2-SMI
DisplayString, RowStatus, TEXTUAL-CONVENTION
FROM SNMPv2-TC;
powerConnect3000MIB MODULE-IDENTITY
LAST-UPDATED "200211250000Z"
ORGANIZATION "Dell Computer Corporation"
CONTACT-INFO
"support.dell.com"
DESCRIPTION
"The private MIB module definition for the Dell powerConnect 3000 Devices."
REVISION "200211250000Z"
DESCRIPTION
"Initial version of this MIB."
::= { enterprises dell(674) dellLan(10895) 3000 }
EnvMonState ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Represents the state of a device being monitored.
Valid values are:
normal(1): the environment is good, such as low
temperature.
warning(2): the environment is bad, such as temperature
above normal operation range but not too
high.
critical(3): the environment is very bad, such as
temperature much higher than normal
operation limit.
shutdown(4): the environment is the worst, the system
should be shutdown immediately.
notPresent(5): the environmental monitor is not present,
such as temperature sensors do not exist.
notFunctioning(6): the environmental monitor does not
function properly, such as a temperature
sensor generates a abnormal data like
1000 C.
"
SYNTAX INTEGER {
normal(1),
warning(2),
critical(3),
shutdown(4),
notPresent(5),
notFunctioning(6)
}
dell-VendorMIBObjects OBJECT IDENTIFIER ::= { powerConnect3000MIB 1 }
dellVendorNotifications OBJECT IDENTIFIER ::= { powerConnect3000MIB 2 }
hardware OBJECT IDENTIFIER ::= { dell-VendorMIBObjects 2 }
productIdentification OBJECT IDENTIFIER ::= { hardware 100 }
productStatus OBJECT IDENTIFIER ::= { hardware 110 }
--
--
-- productIdentification
--
productIdentificationDisplayName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Name of this product for display purposes."
::= { productIdentification 1}
productIdentificationDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A short description of this product such as: Ethernet Router Switch."
::= { productIdentification 2}
productIdentificationVendor OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The name of the product manufacturer, such as: Dell Computer Corp."
::= { productIdentification 3 }
productIdentificationVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The version of this product."
::= { productIdentification 4 }
productIdentificationBuildNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The software build number of the product."
::= { productIdentification 5 }
productIdentificationURL OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The URL of the web-based application to manage this device, should the device provide one.
The format of the value held by this object is: http://<device IP address>."
::= { productIdentification 6 }
productIdentificationDeviceNetworkName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Device Name."
::= { productIdentification 7 }
productIdentificationPerUnitTable OBJECT-TYPE
SYNTAX SEQUENCE OF ProductIdentificationPerBoxEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Identification specific to product instance and, in case of stackable products, per unit. If the product is not stackable,
it will be considered a stack of one unit and therefore this table will contain one conceptual row only."
::= { productIdentification 8 }
productIdentificationPerUnitEntry OBJECT-TYPE
SYNTAX ProductIdentificationPerBoxEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This row applies to a unit in a stackable product. "
INDEX { productIdentificationPerBoxIndex }
::= { productIdentificationPerUnitTable 1 }
ProductIdentificationPerBoxEntry ::= SEQUENCE {
productIdentificationPerBoxIndex INTEGER,
productIdentificationSerialNumber DisplayString,
productIdentificationAssetTag DisplayString,
productIdentificationServiceTag DisplayString
}
productIdentificationPerBoxIndex OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The index of the stack unit to which this conceptual row corresponds.
Note that the index will be the same index as the index
of a 'chassis' physical entity in the entity MIB of the product."
::= { productIdentificationPerUnitEntry 1 }
productIdentificationSerialNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Serial number of the product."
::= { productIdentificationPerUnitEntry 2 }
productIdentificationAssetTag OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Asset tag of the product."
::= { productIdentificationPerUnitEntry 3 }
productIdentificationServiceTag OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Service tag of the product."
::= { productIdentificationPerUnitEntry 4 }
--
-- productStatus
--
productStatusGlobalStatus OBJECT-TYPE
SYNTAX INTEGER {
ok(3),
non-critical(4),
critical(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Current status of the product.This is a rollup for the entire product.
The status is intended to give initiative to a snmp monitor to get further data when this status is abnormal.
This variable can take the following values:
3: OK
If fans and power supplies are functioning and the system did not reboot because of a HW watchdog failure
or a SW fatal error condition.
4: Non-critical
If at least one power supply is not functional or the system rebooted at least once because of a HW watchdog failure
or a SW fatal error condition.
5: Critical
If at least one fan is not functional, possibly causing a dangerous warming up of the device."
::= { productStatus 1 }
productStatusLastGlobalStatus OBJECT-TYPE
SYNTAX INTEGER {
ok(3),
non-critical(4),
critical(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The status before the current status which induced an initiative to issue a global status change trap."
::= { productStatus 2 }
productStatusTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The last time that the product global status has been updated.
The time will be given in TimeTicks"
::= { productStatus 3 }
productStatusGetTimeOut OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Suggested time out value in milliseconds for how long the SNMP getter
should wait while attempting to poll the product SNMP service."
::= { productStatus 4 }
productStatusRefreshRate OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Rate in seconds at which the SNMP service cached data is being updated."
::= { productStatus 5 }
productStatusGeneratingTrapsFlag OBJECT-TYPE
SYNTAX INTEGER { true(1),
false(2),
disabled(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates if this SNMP service is generating SNMP Traps.
This variable can take the following values:
1: true - The device is capable and currently configured to generate traps if necessary.
2: false - The device is not capable of generating traps.
3: disabled - The device is capable but not configured to generate traps.
"
::= { productStatus 6 }
productStatusEnvironment OBJECT IDENTIFIER ::= { productStatus 7}
envMonFanStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF EnvMonFanStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table of fan status maintained by the environmental
monitor."
::= { productStatusEnvironment 1 }
envMonFanStatusEntry OBJECT-TYPE
SYNTAX EnvMonFanStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the fan status table, representing the status of
the associated fan maintained by the environmental monitor."
INDEX { envMonFanStatusIndex }
::= { envMonFanStatusTable 1 }
EnvMonFanStatusEntry ::=
SEQUENCE {
envMonFanStatusIndex INTEGER,
envMonFanStatusDescr DisplayString,
envMonFanState EnvMonState
}
envMonFanStatusIndex OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique index for the fan being instrumented.
This index is for SNMP purposes only, and has no
intrinsic meaning."
::= { envMonFanStatusEntry 1 }
envMonFanStatusDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Textual description of the fan being instrumented.
This description is a short textual label, suitable as a
human-sensible identification for the rest of the
information in the entry."
::= { envMonFanStatusEntry 2 }
envMonFanState OBJECT-TYPE
SYNTAX EnvMonState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The mandatory state of the fan being instrumented."
::= { envMonFanStatusEntry 3 }
envMonSupplyStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF EnvMonSupplyStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table of power supply status maintained by the
environmental monitor card."
::= { productStatusEnvironment 2 }
envMonSupplyStatusEntry OBJECT-TYPE
SYNTAX EnvMonSupplyStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the power supply status table, representing the
status of the associated power supply maintained by the
environmental monitor card."
INDEX { envMonSupplyStatusIndex }
::= { envMonSupplyStatusTable 1 }
EnvMonSupplyStatusEntry ::=
SEQUENCE {
envMonSupplyStatusIndex INTEGER ,
envMonSupplyStatusDescr DisplayString,
envMonSupplyState EnvMonState,
envMonSupplySource INTEGER
}
envMonSupplyStatusIndex OBJECT-TYPE
SYNTAX INTEGER (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Unique index for the power supply being instrumented.
This index is for SNMP purposes only, and has no
intrinsic meaning."
::= { envMonSupplyStatusEntry 1 }
envMonSupplyStatusDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Textual description of the power supply being instrumented.
This description is a short textual label, suitable as a
human-sensible identification for the rest of the
information in the entry."
::= { envMonSupplyStatusEntry 2 }
envMonSupplyState OBJECT-TYPE
SYNTAX EnvMonState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The mandatory state of the power supply being instrumented."
::= { envMonSupplyStatusEntry 3 }
envMonSupplySource OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
ac(2),
dc(3),
externalPowerSupply(4),
internalRedundant(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The power supply source.
unknown - Power supply source unknown
ac - AC power supply
dc - DC power supply
externalPowerSupply - External power supply
internalRedundant - Internal redundant power supply
"
::= { envMonSupplyStatusEntry 4 }
--
-- trap definitions
--
dell-VendorTraps OBJECT IDENTIFIER ::= { dellVendorNotifications 1 }
dell-VendorTrapsPrefix OBJECT IDENTIFIER ::= { dell-VendorTraps 0 }
productStatusGlobalStatusChange NOTIFICATION-TYPE
OBJECTS { productStatusGlobalStatus, productStatusLastGlobalStatus, productStatusTimeStamp }
STATUS current
DESCRIPTION "This trap is sent when the product global status changes."
--#TYPE "Product Global Status Change."
--#SUMMARY "The product global status has changed from %d to %d at time %d."
--#ARGUMENTS {1,0,2}
::= {dell-VendorTrapsPrefix 1 }
END