librenms/mibs/NAS-MIB
Tom Laermans 86fe5825eb properly name NAS-MIB, adamafail
git-svn-id: http://www.observium.org/svn/observer/trunk@1988 61d68cd4-352d-0410-923a-c4978735b2b8
2011-03-29 12:59:54 +00:00

462 lines
12 KiB
Plaintext

NAS-MIB DEFINITIONS ::= BEGIN
IMPORTS
enterprises, Counter, TimeTicks
FROM RFC1155-SMI
OBJECT-TYPE
FROM RFC-1212
TRAP-TYPE
FROM RFC-1215;
-- From RFC-1213 (MIB-II)
DisplayString ::=
OCTET STRING
storage OBJECT IDENTIFIER ::= { enterprises 24681 }
storageSystem OBJECT IDENTIFIER ::= { storage 1 }
-- Frame Relay Multiplexer MIB groups
-- system Event
SystemEventMsg OBJECT IDENTIFIER ::= { storageSystem 1 }
-- system event
EventInformMsg OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS current
DESCRIPTION
"Information event of NAS system."
::= { SystemEventMsg 101 }
EventWarningMsg OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS current
DESCRIPTION
"Warning event of NAS system."
::= { SystemEventMsg 102 }
EventErrorMsg OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS current
DESCRIPTION
"Error event of NAS system."
::= { SystemEventMsg 103 }
SystemTraps OBJECT IDENTIFIER ::= { storageSystem 10 }
EventInform TRAP-TYPE
ENTERPRISE SystemTraps
VARIABLES { EventInformMsg }
DESCRIPTION
"Info: %s"
::= 1
EventWarning TRAP-TYPE
ENTERPRISE SystemTraps
VARIABLES { EventWarningMsg }
DESCRIPTION
"Warn: %s"
::= 2
EventError TRAP-TYPE
ENTERPRISE SystemTraps
VARIABLES { EventErrorMsg }
DESCRIPTION
"Error: %s"
::= 4
-- system inform
SystemInfo OBJECT IDENTIFIER ::= { storageSystem 2 }
SystemCPU-Usage OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"System CPU usage"
::= { SystemInfo 1 }
SystemTotalMem OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"System total memory"
::= { SystemInfo 2 }
SystemFreeMem OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"System free memory"
::= { SystemInfo 3 }
SystemUptime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The amount of time since this host was last
initialized. Note that this is different from
sysUpTime in the SNMPv2-MIB [RFC1907] because
sysUpTime is the uptime of the network management
portion of the system."
::= { SystemInfo 4 }
CPU-Temperature OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"CPU temperature"
::= { SystemInfo 5 }
SystemTemperature OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"System temperature"
::= { SystemInfo 6 }
IfNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of network interfaces (regardless of
their current state) present on this system."
::= { SystemInfo 8 }
SystemIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF IfEntryDef
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of interface entries. The number of
entries is given by the value of IfNumber."
::= { SystemInfo 9 }
IfEntry OBJECT-TYPE
SYNTAX IfEntryDef
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An interface entry containing objects at the
subnetwork layer and below for a particular
interface."
INDEX { IfIndex }
::= { SystemIfTable 1 }
IfEntryDef ::=
SEQUENCE {
IfIndex
INTEGER,
IfDescr
DisplayString,
IfPacketsReceived
Counter,
IfPacketsSent
Counter,
IfErrorPackets
Counter
}
IfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value for each interface. Its value
ranges between 1 and the value of IfNumber. The
value for each interface must remain constant at
least from one re-initialization of the entity's
network management system to the next re-
initialization."
::= { IfEntry 1 }
IfDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A textual string containing information about the
interface. This string should include the name of
the manufacturer, the product name and the version
of the hardware interface."
::= { IfEntry 2 }
IfPacketsReceived OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System packets received."
::= { IfEntry 3 }
IfPacketsSent OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System packets sent."
::= { IfEntry 4 }
IfErrorPackets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System error packets."
::= { IfEntry 5 }
HdNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of hard disk (regardless of
their current state) present on this system."
::= { SystemInfo 10 }
SystemHdTable OBJECT-TYPE
SYNTAX SEQUENCE OF HdEntryDef
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of interface entries. The number of
entries is given by the value of IfNumber."
::= { SystemInfo 11 }
HdEntry OBJECT-TYPE
SYNTAX HdEntryDef
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An interface entry containing objects at the
subnetwork layer and below for a particular
interface."
INDEX { HdIndex }
::= { SystemHdTable 1 }
HdEntryDef ::=
SEQUENCE {
HdIndex
INTEGER,
HdDescr
DisplayString,
HdTemperature
DisplayString,
HdStatus
INTEGER,
HdModel DisplayString,
HdCapacity DisplayString,
HdSmartInfo DisplayString
}
HdIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value for each hard disk. Its value
ranges between 1 and the value of IfNumber. The
value for each interface must remain constant at
least from one re-initialization of the entity's
network management system to the next re-
initialization."
::= { HdEntry 1 }
HdDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A textual string containing information about the
interface. This string should include the name of
the manufacturer, the product name and the version
of the hardware interface."
::= { HdEntry 2 }
HdTemperature OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Hard disk temperature."
::= { HdEntry 3 }
HdStatus OBJECT-TYPE
SYNTAX INTEGER {
ready(0),
noDisk(-5),
invalid(-6),
rwError(-9),
unknown(-4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"HDD status. 0:not availible, 1:availible."
::= { HdEntry 4 }
HdModel OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Hard disk model."
::= { HdEntry 5 }
HdCapacity OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Hard disk capacity."
::= { HdEntry 6 }
HdSmartInfo OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION "Hard disk SMART information."
::= { HdEntry 7 }
ModelName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Model name"
::= { SystemInfo 12 }
HostName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Model name"
::= { SystemInfo 13 }
SysFanNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of system fan (regardless of
their current state) present on this system."
::= { SystemInfo 14 }
SystemFanTable OBJECT-TYPE
SYNTAX SEQUENCE OF SysFanEntryDef
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of interface entries. The number of
entries is given by the value of SysFanNumber."
::= { SystemInfo 15 }
SysFanEntry OBJECT-TYPE
SYNTAX SysFanEntryDef
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An system fan entry containing objects at the
subnetwork layer and below for a particular
interface."
INDEX { SysFanIndex }
::= { SystemFanTable 1 }
SysFanEntryDef ::=
SEQUENCE {
SysFanIndex
INTEGER,
SysFanDescr
DisplayString,
SysFanSpeed
DisplayString
}
SysFanIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value for each system fan. Its value
ranges between 1 and the value of SysFanNumber. The
value for each interface must remain constant at
least from one re-initialization of the entity's
network management system to the next re-
initialization."
::= { SysFanEntry 1 }
SysFanDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A textual string containing information about the
interface. This string should include the name of
the manufacturer, the product name and the version
of the hardware interface."
::= { SysFanEntry 2 }
SysFanSpeed OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System fan speed."
::= { SysFanEntry 3 }
SysVolumeNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of system volumes (regardless of
their current state) present on this system."
::= { SystemInfo 16 }
SystemVolumeTable OBJECT-TYPE
SYNTAX SEQUENCE OF SysVolumeEntryDef
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of volume entries. The number of
entries is given by the value of SysVolumeNumber."
::= { SystemInfo 17 }
SysVolumeEntry OBJECT-TYPE
SYNTAX SysVolumeEntryDef
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An system volume entry"
INDEX { SysVolumeIndex }
::= { SystemVolumeTable 1 }
SysVolumeEntryDef ::=
SEQUENCE {
SysVolumeIndex INTEGER,
SysVolumeDescr DisplayString,
SysVolumeFS DisplayString,
SysVolumeTotalSize DisplayString,
SysVolumeFreeSize DisplayString,
SysVolumeStatus DisplayString
}
SysVolumeIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value for each system volume. Its value
ranges between 1 and the value of SysVolumeNumber. The
value for each volume must remain constant at
least from one re-initialization of the entity's
volume system to the next re-initialization."
::= { SysVolumeEntry 1 }
SysVolumeDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION "A textual string containing information about the volume."
::= { SysVolumeEntry 2 }
SysVolumeFS OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..15))
ACCESS read-only
STATUS mandatory
DESCRIPTION "System Volume file system."
::= { SysVolumeEntry 3 }
SysVolumeTotalSize OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..15))
ACCESS read-only
STATUS mandatory
DESCRIPTION "System Volume total size."
::= { SysVolumeEntry 4 }
SysVolumeFreeSize OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..15))
ACCESS read-only
STATUS mandatory
DESCRIPTION "System Volume free size."
::= { SysVolumeEntry 5 }
SysVolumeStatus OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION "System Volume status."
::= { SysVolumeEntry 6 }
END