-- Rack Information MIB
|
|
-- Management Information Base for SNMP Network Management
|
|
--
|
|
--
|
|
-- Copyright 2002,2003 Hewlett-Packard Development Company, L.P.
|
|
--
|
|
-- Hewlett-Packard Company shall not be liable for technical or
|
|
-- editorial errors or omissions contained herein. The information in
|
|
-- this document is provided "as is" without warranty of any kind and
|
|
-- is subject to change without notice. The warranties for HP products
|
|
-- are set forth in the express limited warranty statements
|
|
-- accompanying such products. Nothing herein should be construed as
|
|
-- constituting an additional warranty.
|
|
--
|
|
-- Confidential computer software. Valid license from HP required for
|
|
-- possession, use or copying. Consistent with FAR 12.211 and 12.212,
|
|
-- Commercial Computer Software, Computer Software Documentation, and
|
|
-- Technical Data for Commercial Items are licensed to the U.S.
|
|
-- Government under vendor's standard commercial license.
|
|
--
|
|
-- Refer to the READMIB.RDM file for more information about the
|
|
-- organization of the information in the Compaq Enterprise.
|
|
--
|
|
-- The Compaq Enterprise number is 232.
|
|
-- The ASN.1 prefix to, and including the Compaq Enterprise is:
|
|
-- 1.3.6.1.4.1.232
|
|
--
|
|
-- ****************************************************************************
|
|
|
|
CPQRACK-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
compaq FROM CPQHOST-MIB
|
|
DisplayString FROM RFC1213-MIB
|
|
OBJECT-TYPE FROM RFC-1212
|
|
sysName FROM RFC1213-MIB
|
|
cpqHoTrapFlags FROM CPQHOST-MIB
|
|
TRAP-TYPE FROM RFC-1215;
|
|
|
|
-- compaq OBJECT IDENTIFIER ::= { enterprises 232 }
|
|
cpqRackInfo OBJECT IDENTIFIER ::= { compaq 22 }
|
|
cpqRackMibRev OBJECT IDENTIFIER ::= { cpqRackInfo 1 }
|
|
cpqRackComponent OBJECT IDENTIFIER ::= { cpqRackInfo 2 }
|
|
cpqRackSysObjID OBJECT IDENTIFIER ::= { cpqRackInfo 3 }
|
|
|
|
cpqRackInterface OBJECT IDENTIFIER ::= { cpqRackComponent 1 }
|
|
cpqRackAsset OBJECT IDENTIFIER ::= { cpqRackComponent 2 }
|
|
cpqRackEnclosure OBJECT IDENTIFIER ::= { cpqRackComponent 3 }
|
|
cpqRackServer OBJECT IDENTIFIER ::= { cpqRackComponent 4 }
|
|
cpqRackPower OBJECT IDENTIFIER ::= { cpqRackComponent 5 }
|
|
cpqRackNetwork OBJECT IDENTIFIER ::= { cpqRackComponent 6 }
|
|
|
|
cpqRackOsCommon OBJECT IDENTIFIER ::= { cpqRackInterface 4 }
|
|
|
|
cpqRackCommonEnclosure OBJECT IDENTIFIER ::= { cpqRackEnclosure 1 }
|
|
cpqRackServerEnclosure OBJECT IDENTIFIER ::= { cpqRackEnclosure 2 }
|
|
cpqRackPowerEnclosure OBJECT IDENTIFIER ::= { cpqRackEnclosure 3 }
|
|
|
|
cpqRackServerBlade OBJECT IDENTIFIER ::= { cpqRackServer 1 }
|
|
|
|
cpqRackPowerSupply OBJECT IDENTIFIER ::= { cpqRackPower 1 }
|
|
|
|
cpqRackNetConnector OBJECT IDENTIFIER ::= { cpqRackNetwork 1 }
|
|
|
|
-- ****************************************************************************
|
|
-- Rack Information MIB Revision
|
|
-- =============================
|
|
--
|
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
|
-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
|
|
-- cpqRackMibRev Group (1.3.6.1.4.1.232.22.1)
|
|
--
|
|
-- Implementation of the MibRev group is mandatory for all Agents
|
|
-- supporting the Rack Information MIB.
|
|
--
|
|
-- An Agent conforming to this document will return a
|
|
-- cpqRackMibRevMajor of one (1) and a cpqRackMibRevMinor of three (3).
|
|
--
|
|
--
|
|
-- ****************************************************************************
|
|
|
|
cpqRackMibRevMajor OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The major revision level of the MIB.
|
|
|
|
A change in the major revision level represents a major change
|
|
in the architecture of the MIB. A change in the major revision
|
|
level may indicate a significant change in the information
|
|
supported and/or the meaning of the supported information,
|
|
correct interpretation of data may require a MIB document with
|
|
the same major revision level."
|
|
::= { cpqRackMibRev 1 }
|
|
|
|
cpqRackMibRevMinor OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minor revision level of the MIB.
|
|
|
|
A change in the minor revision level may represent some minor
|
|
additional support, no changes to any pre-existing information
|
|
has occurred."
|
|
::= { cpqRackMibRev 2 }
|
|
|
|
cpqRackMibCondition OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
ok(2), -- default
|
|
degraded(3),
|
|
failed(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The overall condition.
|
|
|
|
This object represents the overall status of the
|
|
rack information represented by this MIB."
|
|
::= { cpqRackMibRev 3 }
|
|
|
|
-- ****************************************************************************
|
|
-- Rack Information Common
|
|
-- =======================
|
|
--
|
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
|
-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
|
|
-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
|
|
-- cpqRackInterface Group (1.3.6.1.4.1.232.22.2.1)
|
|
-- cpqRackOsCommon Group (1.3.6.1.4.1.232.22.2.1.4)
|
|
--
|
|
--
|
|
-- Implementation of the cpqRackOsCommon group is mandatory for all
|
|
-- Agents that support the Rack Information MIB.
|
|
--
|
|
-- ****************************************************************************
|
|
|
|
cpqRackOsCommonPollFreq OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Management Agent's polling frequency.
|
|
|
|
The frequency, in seconds, at which the Agent requests
|
|
information from the device driver. A frequency of zero (0)
|
|
indicates that the Insight Agent retrieves the information upon
|
|
request of a management station, it does not poll the device
|
|
driver at a specific interval.
|
|
|
|
If the poll frequency is zero (0) all attempts to write to this
|
|
object will fail. If the poll frequency is non-zero,
|
|
setting this value will change the polling frequency of the
|
|
Insight Agent. Setting the poll frequency to zero (0) will
|
|
always fail, an agent may also choose to fail any request to
|
|
change the poll frequency to a value that would severely impact
|
|
system performance."
|
|
::= { cpqRackOsCommon 1 }
|
|
|
|
|
|
-- ****************************************************************************
|
|
-- Rack Asset Group
|
|
-- ================
|
|
--
|
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
|
-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
|
|
-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
|
|
-- cpqRackAsset Group (1.3.6.1.4.1.232.22.2.2)
|
|
--
|
|
-- The cpqRackAsset group contains the serial numbers, names, etc. of any
|
|
-- Rack hardware that supports asset management.
|
|
--
|
|
-- Implementation of the cpqRackAsset group is mandatory for all
|
|
-- Agents that support the Rack Information MIB.
|
|
--
|
|
-- ****************************************************************************
|
|
|
|
-- ****************************************************************************
|
|
-- Rack Asset Table
|
|
-- ================
|
|
--
|
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
|
-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
|
|
-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
|
|
-- cpqRackAsset Group (1.3.6.1.4.1.232.22.2.2)
|
|
-- cpqRackAssetTable (1.3.6.1.4.1.232.22.2.2.1)
|
|
--
|
|
-- ****************************************************************************
|
|
|
|
cpqRackAssetTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CpqRackAssetEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of rack asset information."
|
|
::= { cpqRackAsset 1 }
|
|
|
|
cpqRackAssetEntry OBJECT-TYPE
|
|
SYNTAX CpqRackAssetEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A rack asset description."
|
|
INDEX { cpqRackAssetIndex }
|
|
::= { cpqRackAssetTable 1 }
|
|
|
|
CpqRackAssetEntry ::= SEQUENCE {
|
|
cpqRackAssetIndex INTEGER,
|
|
cpqRackName DisplayString,
|
|
cpqRackUid DisplayString,
|
|
cpqRackSerialNum DisplayString,
|
|
cpqRackTrapSequenceNum INTEGER,
|
|
cpqRackHeight INTEGER,
|
|
cpqRackWidth INTEGER,
|
|
cpqRackDepth INTEGER
|
|
}
|
|
|
|
cpqRackAssetIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A number that uniquely specifies this rack table entry."
|
|
::= { cpqRackAssetEntry 1 }
|
|
|
|
cpqRackName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The customer changeable identifier used to identify the entire
|
|
rack.
|
|
|
|
The string will be empty if the system does not report this
|
|
function."
|
|
::= { cpqRackAssetEntry 2 }
|
|
|
|
cpqRackUid OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The rack unique identifier.
|
|
|
|
The string will be empty if the rack does not report the
|
|
UID or if it could not be determined."
|
|
::= { cpqRackAssetEntry 3 }
|
|
|
|
cpqRackSerialNum OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The rack serial number.
|
|
|
|
The string will be empty if the rack does not report the
|
|
serial number."
|
|
::= { cpqRackAssetEntry 4 }
|
|
|
|
cpqRackTrapSequenceNum OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The trap sequence number for rack traps.
|
|
|
|
This is used by the management application trap processing.
|
|
|
|
This will be -1 if the rack does not report the information or
|
|
it could not be determined."
|
|
::= { cpqRackAssetEntry 5 }
|
|
|
|
cpqRackHeight OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The internal height dimension of the useable rack space expressed
|
|
in millimeters.
|
|
|
|
This will be -1 if the rack does not report the information or
|
|
it could not be determined."
|
|
::= { cpqRackAssetEntry 6 }
|
|
|
|
cpqRackWidth OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The internal width dimension of the useable rack space expressed
|
|
in millimeters.
|
|
|
|
This will be -1 if the rack does not report the information or
|
|
it could not be determined."
|
|
::= { cpqRackAssetEntry 7 }
|
|
|
|
cpqRackDepth OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The internal depth dimension of the useable rack space expressed
|
|
in millimeters.
|
|
|
|
This will be -1 if the rack does not report the information or
|
|
it could not be determined."
|
|
::= { cpqRackAssetEntry 8 }
|
|
|
|
|
|
-- ****************************************************************************
|
|
-- Rack Enclosure Chassis Group
|
|
-- ============================
|
|
--
|
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
|
-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
|
|
-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
|
|
-- cpqRackEnclosure Group (1.3.6.1.4.1.232.22.2.3)
|
|
--
|
|
-- The cpqRackEnclosure group contains the information about rack
|
|
-- enclosures.
|
|
--
|
|
-- ****************************************************************************
|
|
|
|
-- ****************************************************************************
|
|
-- Rack Common Enclosure Table
|
|
-- ===========================
|
|
--
|
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
|
-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
|
|
-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
|
|
-- cpqRackEnclosure Group (1.3.6.1.4.1.232.22.2.3)
|
|
-- cpqRackCommonEnclosure Group (1.3.6.1.4.1.232.22.2.3.1)
|
|
-- cpqRackCommonEnclosureTable (1.3.6.1.4.1.232.22.2.3.1.1)
|
|
--
|
|
-- ****************************************************************************
|
|
|
|
cpqRackCommonEnclosureTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CpqRackCommonEnclosureEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of rack enclosure information."
|
|
::= { cpqRackCommonEnclosure 1 }
|
|
|
|
cpqRackCommonEnclosureEntry OBJECT-TYPE
|
|
SYNTAX CpqRackCommonEnclosureEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A rack enclosure description."
|
|
INDEX { cpqRackCommonEnclosureRack,
|
|
cpqRackCommonEnclosureIndex }
|
|
::= { cpqRackCommonEnclosureTable 1 }
|
|
|
|
CpqRackCommonEnclosureEntry ::= SEQUENCE {
|
|
cpqRackCommonEnclosureRack INTEGER,
|
|
cpqRackCommonEnclosureIndex INTEGER,
|
|
cpqRackCommonEnclosureModel DisplayString,
|
|
cpqRackCommonEnclosureAssetTag DisplayString,
|
|
cpqRackCommonEnclosurePartNumber DisplayString,
|
|
cpqRackCommonEnclosureSparePartNumber DisplayString,
|
|
cpqRackCommonEnclosureSerialNum DisplayString,
|
|
cpqRackCommonEnclosureFWRev DisplayString,
|
|
cpqRackCommonEnclosureName DisplayString,
|
|
cpqRackCommonEnclosureNeighborNamePrev DisplayString,
|
|
cpqRackCommonEnclosureNeighborNameNext DisplayString,
|
|
cpqRackCommonEnclosureHeight INTEGER,
|
|
cpqRackCommonEnclosureWidth INTEGER,
|
|
cpqRackCommonEnclosureDepth INTEGER,
|
|
cpqRackCommonEnclosureTrapSequenceNum INTEGER,
|
|
cpqRackCommonEnclosureCondition INTEGER,
|
|
cpqRackCommonEnclosureHasServerBlades INTEGER,
|
|
cpqRackCommonEnclosureHasPowerSupplies INTEGER,
|
|
cpqRackCommonEnclosureHasNetConnectors INTEGER,
|
|
cpqRackCommonEnclosureHasTempSensors INTEGER,
|
|
cpqRackCommonEnclosureHasFans INTEGER,
|
|
cpqRackCommonEnclosureHasFuses INTEGER,
|
|
cpqRackCommonEnclosureMgmtUID INTEGER,
|
|
cpqRackCommonEnclosureSerialNumPrev DisplayString,
|
|
cpqRackCommonEnclosureSerialNumNext DisplayString,
|
|
cpqRackCommonEnclosureAddress INTEGER,
|
|
cpqRackCommonEnclosureProductId DisplayString,
|
|
cpqRackCommonEnclosureProductIdPrev DisplayString,
|
|
cpqRackCommonEnclosureProductIdNext DisplayString,
|
|
cpqRackCommonEnclosureUUID DisplayString,
|
|
cpqRackCommonEnclosureUUIDPrev DisplayString,
|
|
cpqRackCommonEnclosureUUIDNext DisplayString
|
|
}
|
|
|
|
cpqRackCommonEnclosureRack OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A number that uniquely specifies this rack."
|
|
::= { cpqRackCommonEnclosureEntry 1 }
|
|
|
|
cpqRackCommonEnclosureIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A number that uniquely specifies this enclosure in the rack."
|
|
::= { cpqRackCommonEnclosureEntry 2 }
|
|
|
|
cpqRackCommonEnclosureModel OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The model name of the enclosure.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
model information."
|
|
::= { cpqRackCommonEnclosureEntry 3 }
|
|
|
|
cpqRackCommonEnclosureAssetTag OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The customer changeable asset identifier of the enclosure.
|
|
|
|
The string will be empty if the system does not report this
|
|
function or if the asset tag has not been set."
|
|
::= { cpqRackCommonEnclosureEntry 4 }
|
|
|
|
cpqRackCommonEnclosurePartNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The part number of the enclosure.
|
|
|
|
The string will be empty if the enclosure does not report this
|
|
function."
|
|
::= { cpqRackCommonEnclosureEntry 5 }
|
|
|
|
cpqRackCommonEnclosureSparePartNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The spare part number of the enclosure.
|
|
|
|
The string will be empty if the enclosure does not report this
|
|
function."
|
|
::= { cpqRackCommonEnclosureEntry 6 }
|
|
|
|
cpqRackCommonEnclosureSerialNum OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The serial number of the enclosure.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
serial number."
|
|
::= { cpqRackCommonEnclosureEntry 7 }
|
|
|
|
cpqRackCommonEnclosureFWRev OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The firmware revision of the enclosure.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
firmware revision or does not contain firmware."
|
|
::= { cpqRackCommonEnclosureEntry 8 }
|
|
|
|
cpqRackCommonEnclosureName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the enclosure.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
name or it could not be determined."
|
|
::= { cpqRackCommonEnclosureEntry 9 }
|
|
|
|
cpqRackCommonEnclosureNeighborNamePrev OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the enclosure immediately preceding or above this
|
|
enclosure.
|
|
|
|
The string will be empty if the neighbor enclosure name could not be
|
|
determined or there is no enclosure preceding this one."
|
|
::= { cpqRackCommonEnclosureEntry 10 }
|
|
|
|
cpqRackCommonEnclosureNeighborNameNext OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the enclosure immediately following or below this
|
|
enclosure.
|
|
|
|
The string will be empty if the neighbor enclosure name could not be
|
|
determined or there is no enclosure following this one."
|
|
::= { cpqRackCommonEnclosureEntry 11 }
|
|
|
|
cpqRackCommonEnclosureHeight OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The height dimension of the rack space taken by the
|
|
enclosure expressed in millimeters.
|
|
|
|
This will be -1 if the rack does not report the information or
|
|
it could not be determined."
|
|
::= { cpqRackCommonEnclosureEntry 12 }
|
|
|
|
cpqRackCommonEnclosureWidth OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The width dimension of the rack space taken by the
|
|
enclosure expressed in millimeters.
|
|
|
|
This will be -1 if the rack does not report the information or
|
|
it could not be determined."
|
|
::= { cpqRackCommonEnclosureEntry 13 }
|
|
|
|
cpqRackCommonEnclosureDepth OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The depth dimension of the rack space taken by the
|
|
enclosure expressed in millimeters.
|
|
|
|
This will be -1 if the rack does not report the information or
|
|
it could not be determined."
|
|
::= { cpqRackCommonEnclosureEntry 14 }
|
|
|
|
cpqRackCommonEnclosureTrapSequenceNum OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The trap sequence number for the enclosure.
|
|
|
|
This is used by the management application trap processing.
|
|
|
|
This will be -1 if the rack does not report the information or
|
|
it could not be determined."
|
|
::= { cpqRackCommonEnclosureEntry 15 }
|
|
|
|
cpqRackCommonEnclosureCondition OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
ok(2),
|
|
degraded(3),
|
|
failed(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The overall condition of the enclosure.
|
|
|
|
This is the aggregate of the temperature sensors, fans, and
|
|
fuses within the enclosure.
|
|
|
|
This value will be one of the following:
|
|
|
|
other(1)
|
|
No temperature sensors, fans, or fuses in the enclosure or the
|
|
state could no be determined.
|
|
|
|
ok(2)
|
|
All temperature sensors, fans, and fuses are within the normal
|
|
operating range.
|
|
|
|
degraded(3)
|
|
One or more temperature sensors, fans, or fuses are outside of
|
|
the normal operating range. None are failed.
|
|
|
|
failed(4)
|
|
The temperature sensor exceeded the critical threshold value,
|
|
a required fan has failed, or a fuse has been tripped.
|
|
|
|
The system will automatically shutdown if the failed(4) condition
|
|
results, so it is unlikely that this value will ever be returned
|
|
by the agent."
|
|
::= { cpqRackCommonEnclosureEntry 16 }
|
|
|
|
cpqRackCommonEnclosureHasServerBlades OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(1),
|
|
true(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The enclosure can contain server blades.
|
|
|
|
This will be true(2) is the enclosure can house server blades. The
|
|
cpqRackServerEnclosureTable will contain server enclosure specific
|
|
information.
|
|
|
|
Match the cpqRackCommonEnclosureSerialNum in this table to the
|
|
serial number in the cpqRackServerEnclosureTable to get complete
|
|
information on the server enclosure."
|
|
::= { cpqRackCommonEnclosureEntry 17 }
|
|
|
|
cpqRackCommonEnclosureHasPowerSupplies OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(1),
|
|
true(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The enclosure can contain power supplies.
|
|
|
|
This will be true(2) is the enclosure can house power supplies. The
|
|
cpqRackEnclosurePowerTable will contain power enclosure specific
|
|
information.
|
|
|
|
Match the cpqRackCommonEnclosureSerialNum in this table to the
|
|
serial number in the cpqRackEnclosurePowerTable to get complete
|
|
information on the power enclosure."
|
|
::= { cpqRackCommonEnclosureEntry 18 }
|
|
|
|
cpqRackCommonEnclosureHasNetConnectors OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(1),
|
|
true(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The enclosure contains network connectivity.
|
|
|
|
This will be true(2) is the enclosure contains network connectivity.
|
|
The cpqRackCommonEnclosureNetConnectorTable will contain network
|
|
connectivity specific information.
|
|
|
|
Match the cpqRackCommonEnclosureSerialNum in this table to the
|
|
serial number in the cpqRackCommonEnclosureNetConnectorTable to get complete
|
|
information on the network connector enclosure."
|
|
::= { cpqRackCommonEnclosureEntry 19 }
|
|
|
|
cpqRackCommonEnclosureHasTempSensors OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(1),
|
|
true(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The enclosure contains temperature sensors.
|
|
|
|
This will be true(2) is the enclosure contains
|
|
temperature sensors. The cpqRackCommonEnclosureTempTable will
|
|
contain temperature sensor specific information.
|
|
|
|
Match the cpqRackCommonEnclosureSerialNum in this table to the
|
|
serial number in the cpqRackCommonEnclosureTempTable to get complete
|
|
information on the enclosure."
|
|
::= { cpqRackCommonEnclosureEntry 20 }
|
|
|
|
cpqRackCommonEnclosureHasFans OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(1),
|
|
true(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The enclosure contains fans.
|
|
|
|
This will be true(2) is the enclosure contains fans.
|
|
The cpqRackCommonEnclosureFanTable will contain the fan
|
|
specific information.
|
|
|
|
Match the cpqRackCommonEnclosureSerialNum in this table to the
|
|
serial number in the cpqRackCommonEnclosureFanTable to get complete
|
|
information on the enclosure."
|
|
::= { cpqRackCommonEnclosureEntry 21 }
|
|
|
|
cpqRackCommonEnclosureHasFuses OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(1),
|
|
true(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The enclosure contains fuses.
|
|
|
|
This will be true(2) is the enclosure contains fuses.
|
|
The cpqRackCommonEnclosureFuseTable will contain the fuse
|
|
specific information.
|
|
|
|
Match the cpqRackCommonEnclosureSerialNum in this table to the
|
|
serial number in the cpqRackCommonEnclosureFuseTable to get complete
|
|
information on the enclosure."
|
|
::= { cpqRackCommonEnclosureEntry 22 }
|
|
|
|
cpqRackCommonEnclosureMgmtUID OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1), -- Unknown device or could not be determined
|
|
none(2), -- No Unit Identifier LED present
|
|
ledOn(3), -- Unit Identifier LED is On
|
|
ledOff(4) -- Unit Identifier LED is Off
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Unit Identifier LED.
|
|
|
|
This value will be one of the following:
|
|
|
|
other(1)
|
|
The state of the LED could not be determined. Setting the
|
|
LED state is not allowed.
|
|
|
|
none(2)
|
|
The LED is not present. Setting LED state is not allowed.
|
|
|
|
ledOn(3)
|
|
The LED is present and ON. The LED can be turned off
|
|
by setting the cpqRackCommonEnclosureMgmtUID to ledOff(4).
|
|
|
|
ledOff(4)
|
|
The LED is present and OFF. The LED can be turned on
|
|
by setting the cpqRackCommonEnclosureMgmtUID to ledOn(3)."
|
|
::= { cpqRackCommonEnclosureEntry 23 }
|
|
|
|
cpqRackCommonEnclosureSerialNumPrev OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The serial number of the enclosure immediately preceding or
|
|
above this enclosure.
|
|
|
|
The string will be empty if the neighbor enclosure serial number
|
|
could not be determined or there is no enclosure preceding this one."
|
|
::= { cpqRackCommonEnclosureEntry 24 }
|
|
|
|
cpqRackCommonEnclosureSerialNumNext OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The serial number of the enclosure immediately following or
|
|
below this enclosure.
|
|
|
|
The string will be empty if the neighbor enclosure serial number
|
|
could not be determined or there is no enclosure following this one."
|
|
::= { cpqRackCommonEnclosureEntry 25 }
|
|
|
|
cpqRackCommonEnclosureAddress OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unique address of the enclosure within the rack.
|
|
|
|
This will be -1 if the rack does not report the information or
|
|
it could not be determined."
|
|
::= { cpqRackCommonEnclosureEntry 26 }
|
|
|
|
cpqRackCommonEnclosureProductId OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The product id string of the enclosure.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
product id string."
|
|
::= { cpqRackCommonEnclosureEntry 27 }
|
|
|
|
cpqRackCommonEnclosureProductIdPrev OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The product id string of the enclosure immediately preceding or
|
|
above this enclosure.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
product id string."
|
|
::= { cpqRackCommonEnclosureEntry 28 }
|
|
|
|
cpqRackCommonEnclosureProductIdNext OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The product id string of the enclosure immediately following or
|
|
below this enclosure.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
product id string."
|
|
::= { cpqRackCommonEnclosureEntry 29 }
|
|
|
|
cpqRackCommonEnclosureUUID OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The universal unique identifier string of the enclosure.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
UUID string."
|
|
::= { cpqRackCommonEnclosureEntry 30 }
|
|
|
|
cpqRackCommonEnclosureUUIDPrev OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The universal unique identifier string of the enclosure
|
|
immediately preceding or above this enclosure.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
UUID string or if there is no preceding enclosure."
|
|
::= { cpqRackCommonEnclosureEntry 31 }
|
|
|
|
cpqRackCommonEnclosureUUIDNext OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The universal unique identifier string of the enclosure
|
|
immediately following or below this enclosure.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
UUID string or if there is no following enclosure."
|
|
::= { cpqRackCommonEnclosureEntry 32 }
|
|
|
|
|
|
-- ****************************************************************************
|
|
-- Rack Enclosure Common Temperature Sensor Table
|
|
-- ==============================================
|
|
--
|
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
|
-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
|
|
-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
|
|
-- cpqRackEnclosure Group (1.3.6.1.4.1.232.22.2.3)
|
|
-- cpqRackCommonEnclosure Group (1.3.6.1.4.1.232.22.2.3.1)
|
|
-- cpqRackCommonEnclosureTempTable (1.3.6.1.4.1.232.22.2.3.1.2)
|
|
--
|
|
-- ****************************************************************************
|
|
|
|
cpqRackCommonEnclosureTempTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CpqRackCommonEnclosureTempEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of rack enclosure temperature sensor information."
|
|
::= { cpqRackCommonEnclosure 2 }
|
|
|
|
cpqRackCommonEnclosureTempEntry OBJECT-TYPE
|
|
SYNTAX CpqRackCommonEnclosureTempEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A rack enclosure temperature sensor description."
|
|
INDEX { cpqRackCommonEnclosureTempRack,
|
|
cpqRackCommonEnclosureTempChassis,
|
|
cpqRackCommonEnclosureTempSensorIndex }
|
|
::= { cpqRackCommonEnclosureTempTable 1 }
|
|
|
|
CpqRackCommonEnclosureTempEntry ::= SEQUENCE {
|
|
cpqRackCommonEnclosureTempRack INTEGER,
|
|
cpqRackCommonEnclosureTempChassis INTEGER,
|
|
cpqRackCommonEnclosureTempSensorIndex INTEGER,
|
|
cpqRackCommonEnclosureTempSensorEnclosureName DisplayString,
|
|
cpqRackCommonEnclosureTempLocation DisplayString,
|
|
cpqRackCommonEnclosureTempCurrent INTEGER,
|
|
cpqRackCommonEnclosureTempThreshold INTEGER,
|
|
cpqRackCommonEnclosureTempCondition INTEGER,
|
|
cpqRackCommonEnclosureTempType INTEGER,
|
|
cpqRackCommonEnclosureTempSensorEnclosureSerialNum DisplayString
|
|
}
|
|
|
|
cpqRackCommonEnclosureTempRack OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A number that uniquely specifies this rack."
|
|
::= { cpqRackCommonEnclosureTempEntry 1 }
|
|
|
|
cpqRackCommonEnclosureTempChassis OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A number that uniquely specifies this enclosure in the rack."
|
|
::= { cpqRackCommonEnclosureTempEntry 2 }
|
|
|
|
cpqRackCommonEnclosureTempSensorIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A number that uniquely specifies this temperature sensor within
|
|
this enclosure in the rack."
|
|
::= { cpqRackCommonEnclosureTempEntry 3 }
|
|
|
|
cpqRackCommonEnclosureTempSensorEnclosureName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the enclosure.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
name or it could not be determined."
|
|
::= { cpqRackCommonEnclosureTempEntry 4 }
|
|
|
|
cpqRackCommonEnclosureTempLocation OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The location description of the temperature sensor within the
|
|
enclosure.
|
|
|
|
The string will be empty if the location could not be
|
|
determined."
|
|
::= { cpqRackCommonEnclosureTempEntry 5 }
|
|
|
|
cpqRackCommonEnclosureTempCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is the current temperature sensor reading in degrees
|
|
celsius.
|
|
|
|
If this value cannot be determined by software, then a value
|
|
of -1 will be returned."
|
|
::= { cpqRackCommonEnclosureTempEntry 6 }
|
|
|
|
cpqRackCommonEnclosureTempThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is the threshold temperature sensor setting
|
|
in degrees celsius. This is the temperature in which the
|
|
sensor will be considered to be in a tripped state this
|
|
causing some action to occur depending on the type of
|
|
the sensor. The action of temperature sensor threshold
|
|
will be indicated by the cpqRackCommonEnclosureTempType
|
|
item. If the type is blowout(5), then the temperature sensor
|
|
will cause the fans to speed up. If the type is caution(9),
|
|
then the temperature sensor is in a degraded state. If the
|
|
type is critical(15), then the enclosure will be considered
|
|
as in a failed state.
|
|
|
|
If this value cannot be determined by software, then a value
|
|
of -1 will be returned."
|
|
::= { cpqRackCommonEnclosureTempEntry 7 }
|
|
|
|
cpqRackCommonEnclosureTempCondition OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
ok(2),
|
|
degraded(3),
|
|
failed(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Temperature sensor condition.
|
|
|
|
This value will be one of the following:
|
|
|
|
other(1)
|
|
Temperature could not be determined.
|
|
|
|
ok(2)
|
|
The temperature sensor is within the normal operating range.
|
|
|
|
degraded(3)
|
|
The temperature sensor is outside of the normal operating range.
|
|
|
|
failed(4)
|
|
The temperature sensor detects a condition that could
|
|
possibly damage the system.
|
|
|
|
The system will automatically shutdown if the failed(4) condition
|
|
results, so it is unlikely that this value will ever be returned
|
|
by the agent."
|
|
::= { cpqRackCommonEnclosureTempEntry 8 }
|
|
|
|
cpqRackCommonEnclosureTempType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
blowout(5),
|
|
caution(9),
|
|
critical(15)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This specifies the type of this instance of temperature
|
|
sensor.
|
|
|
|
This value will be one of the following:
|
|
|
|
other(1)
|
|
Temperature threshold type could not be determined.
|
|
|
|
blowout(5)
|
|
If a blowout(5) temperature sensor reaches its threshold,
|
|
the fan or fans in the area of the temperature sensor will
|
|
increase in speed in an attempt to reduce the temperature
|
|
before a caution or critical threshold is reached.
|
|
|
|
caution(9)
|
|
If a caution(9) temperature sensor reaches its threshold, the
|
|
cpqRackCommonEnclosureTempCondition will be set to degraded(3)
|
|
and the system will either continue or shutdown depending
|
|
on the user preferences.
|
|
|
|
critical(15)
|
|
If a critical(15) temperature sensor reaches its threshold,
|
|
the cpqHeTemperatureCondition will be set to failed(4)
|
|
and the system will shutdown."
|
|
::= { cpqRackCommonEnclosureTempEntry 9 }
|
|
|
|
cpqRackCommonEnclosureTempSensorEnclosureSerialNum OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The serial number of the enclosure containing this temperature
|
|
sensor.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
serial number or it could not be determined."
|
|
::= { cpqRackCommonEnclosureTempEntry 10 }
|
|
|
|
|
|
-- ****************************************************************************
|
|
-- Rack Enclosure Common Fan Table
|
|
-- ===============================
|
|
--
|
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
|
-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
|
|
-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
|
|
-- cpqRackEnclosure Group (1.3.6.1.4.1.232.22.2.3)
|
|
-- cpqRackCommonEnclosure Group (1.3.6.1.4.1.232.22.2.3.1)
|
|
-- cpqRackCommonEnclosureFanTable (1.3.6.1.4.1.232.22.2.3.1.3)
|
|
--
|
|
-- ****************************************************************************
|
|
|
|
cpqRackCommonEnclosureFanTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CpqRackCommonEnclosureFanEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of rack enclosure fan information."
|
|
::= { cpqRackCommonEnclosure 3 }
|
|
|
|
cpqRackCommonEnclosureFanEntry OBJECT-TYPE
|
|
SYNTAX CpqRackCommonEnclosureFanEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A rack enclosure fan description."
|
|
INDEX { cpqRackCommonEnclosureFanRack,
|
|
cpqRackCommonEnclosureFanChassis,
|
|
cpqRackCommonEnclosureFanIndex }
|
|
::= { cpqRackCommonEnclosureFanTable 1 }
|
|
|
|
CpqRackCommonEnclosureFanEntry ::= SEQUENCE {
|
|
cpqRackCommonEnclosureFanRack INTEGER,
|
|
cpqRackCommonEnclosureFanChassis INTEGER,
|
|
cpqRackCommonEnclosureFanIndex INTEGER,
|
|
cpqRackCommonEnclosureFanEnclosureName DisplayString,
|
|
cpqRackCommonEnclosureFanLocation DisplayString,
|
|
cpqRackCommonEnclosureFanPartNumber DisplayString,
|
|
cpqRackCommonEnclosureFanSparePartNumber DisplayString,
|
|
cpqRackCommonEnclosureFanPresent INTEGER,
|
|
cpqRackCommonEnclosureFanRedundant INTEGER,
|
|
cpqRackCommonEnclosureFanRedundantGroupId INTEGER,
|
|
cpqRackCommonEnclosureFanCondition INTEGER,
|
|
cpqRackCommonEnclosureFanEnclosureSerialNum DisplayString
|
|
}
|
|
|
|
cpqRackCommonEnclosureFanRack OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A number that uniquely specifies this rack."
|
|
::= { cpqRackCommonEnclosureFanEntry 1 }
|
|
|
|
cpqRackCommonEnclosureFanChassis OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A number that uniquely specifies this enclosure in the rack."
|
|
::= { cpqRackCommonEnclosureFanEntry 2 }
|
|
|
|
cpqRackCommonEnclosureFanIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A number that uniquely specifies this fan within this
|
|
enclosure in the rack."
|
|
::= { cpqRackCommonEnclosureFanEntry 3 }
|
|
|
|
cpqRackCommonEnclosureFanEnclosureName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the enclosure.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
name or it could not be determined."
|
|
::= { cpqRackCommonEnclosureFanEntry 4 }
|
|
|
|
cpqRackCommonEnclosureFanLocation OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The location description of the fan within the enclosure.
|
|
|
|
The string will be empty if the location could not be
|
|
determined."
|
|
::= { cpqRackCommonEnclosureFanEntry 5 }
|
|
|
|
cpqRackCommonEnclosureFanPartNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The part number of the enclosure fan.
|
|
|
|
The string will be empty if the part number could not be
|
|
determined."
|
|
::= { cpqRackCommonEnclosureFanEntry 6 }
|
|
|
|
cpqRackCommonEnclosureFanSparePartNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The spare part number of the enclosure fan.
|
|
|
|
The string will be empty if the part number could not be
|
|
determined."
|
|
::= { cpqRackCommonEnclosureFanEntry 7 }
|
|
|
|
cpqRackCommonEnclosureFanPresent OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
absent(2),
|
|
present(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This specifies if the fan described is present in the system."
|
|
::= { cpqRackCommonEnclosureFanEntry 8 }
|
|
|
|
cpqRackCommonEnclosureFanRedundant OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
notRedundant(2),
|
|
redundant(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This specifies if the fan is in a redundant configuration."
|
|
::= { cpqRackCommonEnclosureFanEntry 9 }
|
|
|
|
cpqRackCommonEnclosureFanRedundantGroupId OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This specifies the group number for redundant fans within this
|
|
enclosure."
|
|
::= { cpqRackCommonEnclosureFanEntry 10 }
|
|
|
|
cpqRackCommonEnclosureFanCondition OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
ok(2),
|
|
degraded(3),
|
|
failed(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The condition of the fan.
|
|
|
|
This value will be one of the following:
|
|
|
|
other(1)
|
|
Fan status detection is not supported.
|
|
|
|
ok(2)
|
|
The fan is operating properly.
|
|
|
|
degraded(2)
|
|
A redundant fan is not operating properly.
|
|
|
|
failed(4)
|
|
A non-redundant fan is not operating properly."
|
|
::= { cpqRackCommonEnclosureFanEntry 11 }
|
|
|
|
cpqRackCommonEnclosureFanEnclosureSerialNum OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The serial number of the enclosure containing the fan.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
serial number or it could not be determined."
|
|
::= { cpqRackCommonEnclosureFanEntry 12 }
|
|
|
|
|
|
-- ****************************************************************************
|
|
-- Rack Enclosure Common Fuse Table
|
|
-- ================================
|
|
--
|
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
|
-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
|
|
-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
|
|
-- cpqRackEnclosure Group (1.3.6.1.4.1.232.22.2.3)
|
|
-- cpqRackCommonEnclosure Group (1.3.6.1.4.1.232.22.2.3.1)
|
|
-- cpqRackCommonEnclosureFuseTable (1.3.6.1.4.1.232.22.2.3.1.4)
|
|
--
|
|
-- ****************************************************************************
|
|
|
|
cpqRackCommonEnclosureFuseTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CpqRackCommonEnclosureFuseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of rack enclosure fuse information."
|
|
::= { cpqRackCommonEnclosure 4 }
|
|
|
|
cpqRackCommonEnclosureFuseEntry OBJECT-TYPE
|
|
SYNTAX CpqRackCommonEnclosureFuseEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A rack enclosure fuse description."
|
|
INDEX { cpqRackCommonEnclosureFuseRack,
|
|
cpqRackCommonEnclosureFuseChassis,
|
|
cpqRackCommonEnclosureFuseIndex }
|
|
::= { cpqRackCommonEnclosureFuseTable 1 }
|
|
|
|
CpqRackCommonEnclosureFuseEntry ::= SEQUENCE {
|
|
cpqRackCommonEnclosureFuseRack INTEGER,
|
|
cpqRackCommonEnclosureFuseChassis INTEGER,
|
|
cpqRackCommonEnclosureFuseIndex INTEGER,
|
|
cpqRackCommonEnclosureFuseEnclosureName DisplayString,
|
|
cpqRackCommonEnclosureFuseLocation DisplayString,
|
|
cpqRackCommonEnclosureFusePresent INTEGER,
|
|
cpqRackCommonEnclosureFuseCondition INTEGER
|
|
}
|
|
|
|
cpqRackCommonEnclosureFuseRack OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A number that uniquely specifies this rack."
|
|
::= { cpqRackCommonEnclosureFuseEntry 1 }
|
|
|
|
cpqRackCommonEnclosureFuseChassis OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A number that uniquely specifies this enclosure in the rack."
|
|
::= { cpqRackCommonEnclosureFuseEntry 2 }
|
|
|
|
cpqRackCommonEnclosureFuseIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A number that uniquely specifies the fuse within this enclosure."
|
|
::= { cpqRackCommonEnclosureFuseEntry 3 }
|
|
|
|
cpqRackCommonEnclosureFuseEnclosureName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the enclosure.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
name or it could not be determined."
|
|
::= { cpqRackCommonEnclosureFuseEntry 4 }
|
|
|
|
cpqRackCommonEnclosureFuseLocation OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The location description of the fuse within the enclosure.
|
|
|
|
The string will be empty if the location could not be
|
|
determined."
|
|
::= { cpqRackCommonEnclosureFuseEntry 5 }
|
|
|
|
cpqRackCommonEnclosureFusePresent OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
absent(2),
|
|
present(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This specifies if the fuse described is present in the system."
|
|
::= { cpqRackCommonEnclosureFuseEntry 6 }
|
|
|
|
cpqRackCommonEnclosureFuseCondition OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
ok(2),
|
|
failed(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The condition of the fuse.
|
|
|
|
This value will be one of the following:
|
|
|
|
other(1)
|
|
Fuse status detection is not supported.
|
|
|
|
ok(2)
|
|
The fuse is operating properly.
|
|
|
|
failed(4)
|
|
A fuse has been tripped or is not operating properly."
|
|
::= { cpqRackCommonEnclosureFuseEntry 7 }
|
|
|
|
-- ****************************************************************************
|
|
-- Rack Enclosure Common FRU Table
|
|
-- ===============================
|
|
--
|
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
|
-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
|
|
-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
|
|
-- cpqRackEnclosure Group (1.3.6.1.4.1.232.22.2.3)
|
|
-- cpqRackCommonEnclosure Group (1.3.6.1.4.1.232.22.2.3.1)
|
|
-- cpqRackCommonEnclosureFruTable (1.3.6.1.4.1.232.22.2.3.1.5)
|
|
--
|
|
-- ****************************************************************************
|
|
|
|
cpqRackCommonEnclosureFruTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CpqRackCommonEnclosureFruEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of rack enclosure field replaceable units information."
|
|
::= { cpqRackCommonEnclosure 5 }
|
|
|
|
cpqRackCommonEnclosureFruEntry OBJECT-TYPE
|
|
SYNTAX CpqRackCommonEnclosureFruEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A rack enclosure field replaceable unit description."
|
|
INDEX { cpqRackCommonEnclosureFruRack,
|
|
cpqRackCommonEnclosureFruChassis,
|
|
cpqRackCommonEnclosureFruIndex }
|
|
::= { cpqRackCommonEnclosureFruTable 1 }
|
|
|
|
CpqRackCommonEnclosureFruEntry ::= SEQUENCE {
|
|
cpqRackCommonEnclosureFruRack INTEGER,
|
|
cpqRackCommonEnclosureFruChassis INTEGER,
|
|
cpqRackCommonEnclosureFruIndex INTEGER,
|
|
cpqRackCommonEnclosureFruEnclosureName DisplayString,
|
|
cpqRackCommonEnclosureFruDescription DisplayString,
|
|
cpqRackCommonEnclosureFruLocation DisplayString,
|
|
cpqRackCommonEnclosureFruAssemblyPartNumber DisplayString,
|
|
cpqRackCommonEnclosureFruSparePartNumber DisplayString,
|
|
cpqRackCommonEnclosureFruAutoRev DisplayString,
|
|
cpqRackCommonEnclosureFruSerialNum DisplayString
|
|
}
|
|
|
|
cpqRackCommonEnclosureFruRack OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A number that uniquely specifies this rack."
|
|
::= { cpqRackCommonEnclosureFruEntry 1 }
|
|
|
|
cpqRackCommonEnclosureFruChassis OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A number that uniquely specifies this enclosure in the rack."
|
|
::= { cpqRackCommonEnclosureFruEntry 2 }
|
|
|
|
cpqRackCommonEnclosureFruIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A number that uniquely specifies the FRU within this enclosure."
|
|
::= { cpqRackCommonEnclosureFruEntry 3 }
|
|
|
|
cpqRackCommonEnclosureFruEnclosureName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the enclosure.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
name or it could not be determined."
|
|
::= { cpqRackCommonEnclosureFruEntry 4 }
|
|
|
|
cpqRackCommonEnclosureFruDescription OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A description of the FRU component.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
description information."
|
|
::= { cpqRackCommonEnclosureFruEntry 5 }
|
|
|
|
cpqRackCommonEnclosureFruLocation OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The location description of the FRU within the enclosure.
|
|
|
|
The string will be empty if the location could not be
|
|
determined."
|
|
::= { cpqRackCommonEnclosureFruEntry 6 }
|
|
|
|
cpqRackCommonEnclosureFruAssemblyPartNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The assembly part number of the FRU within the enclosure.
|
|
|
|
The string will be empty if the enclosure does not report this
|
|
information."
|
|
::= { cpqRackCommonEnclosureFruEntry 7 }
|
|
|
|
cpqRackCommonEnclosureFruSparePartNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The spare part number of the FRU within the enclosure.
|
|
|
|
The string will be empty if the enclosure does not report this
|
|
information."
|
|
::= { cpqRackCommonEnclosureFruEntry 8 }
|
|
|
|
cpqRackCommonEnclosureFruAutoRev OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The auto revision number of the FRU within the enclosure.
|
|
|
|
The string will be empty if the enclosure does not report this
|
|
information."
|
|
::= { cpqRackCommonEnclosureFruEntry 9 }
|
|
|
|
cpqRackCommonEnclosureFruSerialNum OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The serial number of the FRU within the enclosure.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
serial number."
|
|
::= { cpqRackCommonEnclosureFruEntry 10 }
|
|
|
|
-- ****************************************************************************
|
|
-- Rack Enclosure for Servers Table
|
|
-- ================================
|
|
--
|
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
|
-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
|
|
-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
|
|
-- cpqRackEnclosure Group (1.3.6.1.4.1.232.22.2.3)
|
|
-- cpqRackServerEnclosure Group (1.3.6.1.4.1.232.22.2.3.2)
|
|
-- cpqRackServerEnclosureTable (1.3.6.1.4.1.232.22.2.3.2.1)
|
|
--
|
|
-- ****************************************************************************
|
|
|
|
cpqRackServerEnclosureTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CpqRackServerEnclosureEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of rack enclosure information for servers."
|
|
::= { cpqRackServerEnclosure 1 }
|
|
|
|
cpqRackServerEnclosureEntry OBJECT-TYPE
|
|
SYNTAX CpqRackServerEnclosureEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A server enclosure description."
|
|
INDEX { cpqRackServerEnclosureRack,
|
|
cpqRackServerEnclosureIndex }
|
|
::= { cpqRackServerEnclosureTable 1 }
|
|
|
|
CpqRackServerEnclosureEntry ::= SEQUENCE {
|
|
cpqRackServerEnclosureRack INTEGER,
|
|
cpqRackServerEnclosureIndex INTEGER,
|
|
cpqRackServerEnclosureName DisplayString,
|
|
cpqRackServerEnclosureMaxNumBlades INTEGER,
|
|
cpqRackServerEnclosureMaxNumBladesX INTEGER,
|
|
cpqRackServerEnclosureMaxNumBladesY INTEGER
|
|
}
|
|
|
|
cpqRackServerEnclosureRack OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A number that uniquely specifies this rack."
|
|
::= { cpqRackServerEnclosureEntry 1 }
|
|
|
|
cpqRackServerEnclosureIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A number that uniquely specifies this server enclosure in the rack."
|
|
::= { cpqRackServerEnclosureEntry 2 }
|
|
|
|
cpqRackServerEnclosureName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the server enclosure.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
name or it could not be determined."
|
|
::= { cpqRackServerEnclosureEntry 3 }
|
|
|
|
cpqRackServerEnclosureMaxNumBlades OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum number of server blades the enclosure can contain.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
name or it could not be determined."
|
|
::= { cpqRackServerEnclosureEntry 4 }
|
|
|
|
cpqRackServerEnclosureMaxNumBladesX OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum number of server blades in x-direction (from left to right)
|
|
the enclosure can contain."
|
|
|
|
::= { cpqRackServerEnclosureEntry 5 }
|
|
|
|
cpqRackServerEnclosureMaxNumBladesY OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum number of server blades in y-direction (from top to bottom)
|
|
the enclosure can contain."
|
|
|
|
::= { cpqRackServerEnclosureEntry 6 }
|
|
|
|
|
|
-- ****************************************************************************
|
|
-- Rack Enclosure for Power Supplies Table
|
|
-- =======================================
|
|
--
|
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
|
-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
|
|
-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
|
|
-- cpqRackEnclosure Group (1.3.6.1.4.1.232.22.2.3)
|
|
-- cpqRackPowerEnclosure Group (1.3.6.1.4.1.232.22.2.3.3)
|
|
-- cpqRackPowerEnclosureTable (1.3.6.1.4.1.232.22.2.3.3.1)
|
|
--
|
|
-- ****************************************************************************
|
|
|
|
cpqRackPowerEnclosureTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CpqRackPowerEnclosureEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of rack power enclosure information."
|
|
::= { cpqRackPowerEnclosure 1 }
|
|
|
|
cpqRackPowerEnclosureEntry OBJECT-TYPE
|
|
SYNTAX CpqRackPowerEnclosureEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A rack power enclosure description."
|
|
INDEX { cpqRackPowerEnclosureRack,
|
|
cpqRackPowerEnclosureIndex }
|
|
::= { cpqRackPowerEnclosureTable 1 }
|
|
|
|
CpqRackPowerEnclosureEntry ::= SEQUENCE {
|
|
cpqRackPowerEnclosureRack INTEGER,
|
|
cpqRackPowerEnclosureIndex INTEGER,
|
|
cpqRackPowerEnclosureName DisplayString,
|
|
cpqRackPowerEnclosureMgmtBoardSerialNum DisplayString,
|
|
cpqRackPowerEnclosureRedundant INTEGER,
|
|
cpqRackPowerEnclosureLoadBalanced INTEGER,
|
|
cpqRackPowerEnclosureInputPwrType INTEGER,
|
|
cpqRackPowerEnclosurePwrFeedMax INTEGER,
|
|
cpqRackPowerEnclosureCondition INTEGER
|
|
}
|
|
|
|
cpqRackPowerEnclosureRack OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A number that uniquely specifies this rack."
|
|
::= { cpqRackPowerEnclosureEntry 1 }
|
|
|
|
cpqRackPowerEnclosureIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A number that uniquely specifies this power enclosure in the rack."
|
|
::= { cpqRackPowerEnclosureEntry 2 }
|
|
|
|
cpqRackPowerEnclosureName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the power enclosure.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
name or it could not be determined."
|
|
::= { cpqRackPowerEnclosureEntry 3 }
|
|
|
|
cpqRackPowerEnclosureMgmtBoardSerialNum OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The serial number of the enclosure.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
serial number."
|
|
::= { cpqRackPowerEnclosureEntry 4 }
|
|
|
|
cpqRackPowerEnclosureRedundant OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
notRedundant(2),
|
|
redundant(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This indicates if the power supply enclosure is in a redundant
|
|
state."
|
|
::= { cpqRackPowerEnclosureEntry 5 }
|
|
|
|
cpqRackPowerEnclosureLoadBalanced OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
notLoadBalanced(2),
|
|
loadBalanced(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This indicates if the power supply enclosure is in a load
|
|
balanced state."
|
|
::= { cpqRackPowerEnclosureEntry 6 }
|
|
|
|
cpqRackPowerEnclosureInputPwrType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
singlePhase(2),
|
|
threePhase(3),
|
|
directCurrent(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This indicates type of input facility power."
|
|
::= { cpqRackPowerEnclosureEntry 7 }
|
|
|
|
cpqRackPowerEnclosurePwrFeedMax OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is the maximum facility power in watts.
|
|
|
|
The maximum facility power being fed to this power enclosure.
|
|
|
|
The value will be -1 if the power enclosure does not report the
|
|
value or if the value is not known."
|
|
::= { cpqRackPowerEnclosureEntry 8 }
|
|
|
|
cpqRackPowerEnclosureCondition OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
ok(2),
|
|
degraded(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This indicates current condition of the power enclosure.
|
|
|
|
other(1)
|
|
The power enclosure condition could not be determined.
|
|
|
|
ok(2)
|
|
The power enclosure is operating normally.
|
|
|
|
degraded(3)
|
|
The power enclosure is in a degraded state. The power subsystem
|
|
may not be load balanced or may have lost redundancy."
|
|
::= { cpqRackPowerEnclosureEntry 9 }
|
|
|
|
|
|
-- ****************************************************************************
|
|
-- Rack Server Blade Table
|
|
-- =======================
|
|
--
|
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
|
-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
|
|
-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
|
|
-- cpqRackServer Group (1.3.6.1.4.1.232.22.2.4)
|
|
-- cpqRackServerBlade Group (1.3.6.1.4.1.232.22.2.4.1)
|
|
-- cpqRackServerBladeTable (1.3.6.1.4.1.232.22.2.4.1.1)
|
|
--
|
|
-- ****************************************************************************
|
|
|
|
cpqRackServerBladeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CpqRackServerBladeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of rack server blade information."
|
|
::= { cpqRackServerBlade 1 }
|
|
|
|
cpqRackServerBladeEntry OBJECT-TYPE
|
|
SYNTAX CpqRackServerBladeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A rack server blade description."
|
|
INDEX { cpqRackServerBladeRack,
|
|
cpqRackServerBladeChassis,
|
|
cpqRackServerBladeIndex }
|
|
::= { cpqRackServerBladeTable 1 }
|
|
|
|
CpqRackServerBladeEntry ::= SEQUENCE {
|
|
cpqRackServerBladeRack INTEGER,
|
|
cpqRackServerBladeChassis INTEGER,
|
|
cpqRackServerBladeIndex INTEGER,
|
|
cpqRackServerBladeName DisplayString,
|
|
cpqRackServerBladeEnclosureName DisplayString,
|
|
cpqRackServerBladePartNumber DisplayString,
|
|
cpqRackServerBladeSparePartNumber DisplayString,
|
|
cpqRackServerBladePosition INTEGER,
|
|
cpqRackServerBladeHeight INTEGER,
|
|
cpqRackServerBladeWidth INTEGER,
|
|
cpqRackServerBladeDepth INTEGER,
|
|
cpqRackServerBladePresent INTEGER,
|
|
cpqRackServerBladeHasFuses INTEGER,
|
|
cpqRackServerBladeEnclosureSerialNum DisplayString,
|
|
cpqRackServerBladeSlotsUsed INTEGER,
|
|
cpqRackServerBladeSerialNum DisplayString,
|
|
cpqRackServerBladeProductId DisplayString,
|
|
cpqRackServerBladeUid DisplayString,
|
|
cpqRackServerBladeSlotsUsedX INTEGER,
|
|
cpqRackServerBladeSlotsUsedY INTEGER
|
|
}
|
|
|
|
cpqRackServerBladeRack OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A number that uniquely specifies this rack."
|
|
::= { cpqRackServerBladeEntry 1 }
|
|
|
|
cpqRackServerBladeChassis OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A number that uniquely specifies this enclosure in the rack."
|
|
::= { cpqRackServerBladeEntry 2 }
|
|
|
|
cpqRackServerBladeIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A number that uniquely specifies this server blade within the enclosure."
|
|
::= { cpqRackServerBladeEntry 3 }
|
|
|
|
cpqRackServerBladeName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the server blade.
|
|
|
|
The string will be empty if it could not be determined."
|
|
::= { cpqRackServerBladeEntry 4 }
|
|
|
|
cpqRackServerBladeEnclosureName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the enclosure which contains the blade.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
name or it could not be determined."
|
|
::= { cpqRackServerBladeEntry 5 }
|
|
|
|
cpqRackServerBladePartNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The part number of the server blade.
|
|
|
|
The string will be empty if the part number could not be
|
|
determined."
|
|
::= { cpqRackServerBladeEntry 6 }
|
|
|
|
cpqRackServerBladeSparePartNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The spare part number of the server blade.
|
|
|
|
The string will be empty if the part number could not be
|
|
determined."
|
|
::= { cpqRackServerBladeEntry 7 }
|
|
|
|
cpqRackServerBladePosition OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The position or slot number of the server blade within the
|
|
server enclosure.
|
|
|
|
This will be -1 if the server enclosure does not report the
|
|
information or it could not be determined."
|
|
::= { cpqRackServerBladeEntry 8 }
|
|
|
|
cpqRackServerBladeHeight OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The height dimension of the rack space taken by the server
|
|
blade expressed in millimeters.
|
|
|
|
This will be -1 if the rack does not report the information or
|
|
it could not be determined."
|
|
::= { cpqRackServerBladeEntry 9 }
|
|
|
|
cpqRackServerBladeWidth OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The width dimension of the rack space taken by the server
|
|
blade expressed in millimeters.
|
|
|
|
This will be -1 if the rack does not report the information or
|
|
it could not be determined."
|
|
::= { cpqRackServerBladeEntry 10 }
|
|
|
|
cpqRackServerBladeDepth OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The depth dimension of the rack space taken by the server
|
|
blade expressed in millimeters.
|
|
|
|
This will be -1 if the rack does not report the information or
|
|
it could not be determined."
|
|
::= { cpqRackServerBladeEntry 11 }
|
|
|
|
cpqRackServerBladePresent OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
absent(2),
|
|
present(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This specifies if the server blade described is present in the
|
|
enclosure."
|
|
::= { cpqRackServerBladeEntry 12 }
|
|
|
|
cpqRackServerBladeHasFuses OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(1),
|
|
true(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The server blade contains fuses.
|
|
|
|
This will be true(2) is the server blade contains fuses.
|
|
The cpqRackCommonEnclosureFuseTable will contain the fuse
|
|
specific information.
|
|
|
|
Match the cpqRackServerBladeEnclosureSerialNum in this table to the
|
|
serial number in the cpqRackCommonEnclosureFanTable to get complete
|
|
information on the fuses."
|
|
::= { cpqRackServerBladeEntry 13 }
|
|
|
|
cpqRackServerBladeEnclosureSerialNum OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The serial number of the enclosure which contains the blade.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
serial number or it could not be determined."
|
|
::= { cpqRackServerBladeEntry 14 }
|
|
|
|
cpqRackServerBladeSlotsUsed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of slot positions occupied by this server blade. This
|
|
is used to indicate a server blade which may obscure an adjacent
|
|
blade slot.
|
|
|
|
This will be -1 if the rack does not report the information or
|
|
it could not be determined."
|
|
::= { cpqRackServerBladeEntry 15 }
|
|
|
|
cpqRackServerBladeSerialNum OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The serial number of the server blade.
|
|
|
|
The string will be empty if the system does not report the
|
|
serial number function."
|
|
::= { cpqRackServerBladeEntry 16 }
|
|
|
|
cpqRackServerBladeProductId OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The product id string of the server blade.
|
|
|
|
The string will be empty if the system does not report the
|
|
product id function."
|
|
::= { cpqRackServerBladeEntry 17 }
|
|
|
|
cpqRackServerBladeUid OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The server blade unique identifier.
|
|
|
|
The string will be empty if the blade does not report the
|
|
UID or if it could not be determined."
|
|
::= { cpqRackServerBladeEntry 18 }
|
|
|
|
cpqRackServerBladeSlotsUsedX OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of slot positions in x-direction (from left to right)
|
|
occupied by this server blade. This is used to indicate a server blade
|
|
which may obscure an adjacent blade slot.
|
|
|
|
This will be -1 if the rack does not report the information or
|
|
it could not be determined."
|
|
::= { cpqRackServerBladeEntry 19 }
|
|
|
|
cpqRackServerBladeSlotsUsedY OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of slot positions in y-direction (from top to bottom)
|
|
occupied by this server blade. This is used to indicate a server blade
|
|
which may obscure an adjacent blade slot.
|
|
|
|
This will be -1 if the rack does not report the information or
|
|
it could not be determined."
|
|
::= { cpqRackServerBladeEntry 20 }
|
|
|
|
|
|
-- ****************************************************************************
|
|
-- Rack Power Supply Table
|
|
-- =======================
|
|
--
|
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
|
-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
|
|
-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
|
|
-- cpqRackPower Group (1.3.6.1.4.1.232.22.2.5)
|
|
-- cpqRackPowerSupply Group (1.3.6.1.4.1.232.22.2.5.1)
|
|
-- cpqRackPowerSupplyTable (1.3.6.1.4.1.232.22.2.5.1.1)
|
|
--
|
|
-- ****************************************************************************
|
|
|
|
cpqRackPowerSupplyTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CpqRackPowerSupplyEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of rack power supply information."
|
|
::= { cpqRackPowerSupply 1 }
|
|
|
|
cpqRackPowerSupplyEntry OBJECT-TYPE
|
|
SYNTAX CpqRackPowerSupplyEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A rack power supply description."
|
|
INDEX { cpqRackPowerSupplyRack,
|
|
cpqRackPowerSupplyChassis,
|
|
cpqRackPowerSupplyIndex }
|
|
::= { cpqRackPowerSupplyTable 1 }
|
|
|
|
CpqRackPowerSupplyEntry ::= SEQUENCE {
|
|
cpqRackPowerSupplyRack INTEGER,
|
|
cpqRackPowerSupplyChassis INTEGER,
|
|
cpqRackPowerSupplyIndex INTEGER,
|
|
cpqRackPowerSupplyEnclosureName DisplayString,
|
|
cpqRackPowerSupplySerialNum DisplayString,
|
|
cpqRackPowerSupplyPartNumber DisplayString,
|
|
cpqRackPowerSupplySparePartNumber DisplayString,
|
|
cpqRackPowerSupplyFWRev DisplayString,
|
|
cpqRackPowerSupplyMaxPwrOutput INTEGER,
|
|
cpqRackPowerSupplyCurPwrOutput INTEGER,
|
|
cpqRackPowerSupplyPosition INTEGER,
|
|
cpqRackPowerSupplyIntakeTemp INTEGER,
|
|
cpqRackPowerSupplyExhaustTemp INTEGER,
|
|
cpqRackPowerSupplyStatus INTEGER,
|
|
cpqRackPowerSupplyInputLineStatus INTEGER,
|
|
cpqRackPowerSupplyPresent INTEGER,
|
|
cpqRackPowerSupplyCondition INTEGER,
|
|
cpqRackPowerSupplyEnclosureSerialNum DisplayString
|
|
}
|
|
|
|
cpqRackPowerSupplyRack OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A number that uniquely specifies this rack."
|
|
::= { cpqRackPowerSupplyEntry 1 }
|
|
|
|
cpqRackPowerSupplyChassis OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A number that uniquely specifies this power enclosure in the rack."
|
|
::= { cpqRackPowerSupplyEntry 2 }
|
|
|
|
cpqRackPowerSupplyIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A number that uniquely specifies this power supply in the enclosure."
|
|
::= { cpqRackPowerSupplyEntry 3 }
|
|
|
|
cpqRackPowerSupplyEnclosureName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the power supply enclosure in which this power supply
|
|
resides.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
name or it could not be determined."
|
|
::= { cpqRackPowerSupplyEntry 4 }
|
|
|
|
cpqRackPowerSupplySerialNum OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The serial number of the power supply.
|
|
|
|
The string will be empty if the power supply does not report the
|
|
serial number."
|
|
::= { cpqRackPowerSupplyEntry 5 }
|
|
|
|
cpqRackPowerSupplyPartNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The part number of the power supply.
|
|
|
|
The string will be empty if the power supply does not report this
|
|
function."
|
|
::= { cpqRackPowerSupplyEntry 6 }
|
|
|
|
cpqRackPowerSupplySparePartNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The spare part number of the power supply.
|
|
|
|
The string will be empty if the power supply does not report this
|
|
function."
|
|
::= { cpqRackPowerSupplyEntry 7 }
|
|
|
|
cpqRackPowerSupplyFWRev OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The firmware revision of the power supply.
|
|
|
|
The string will be empty if the power supply does not report the
|
|
firmware revision."
|
|
::= { cpqRackPowerSupplyEntry 8 }
|
|
|
|
cpqRackPowerSupplyMaxPwrOutput OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum power output of the power supply in watts.
|
|
|
|
The value will be -1 if the power supply does not report the
|
|
value."
|
|
::= { cpqRackPowerSupplyEntry 9 }
|
|
|
|
cpqRackPowerSupplyCurPwrOutput OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current power output of the power supply in watts.
|
|
|
|
The value will be -1 if the power supply does not report the
|
|
value."
|
|
::= { cpqRackPowerSupplyEntry 10 }
|
|
|
|
cpqRackPowerSupplyPosition OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The position of the power supply within the power enclosure.
|
|
|
|
This will be -1 if the power enclosure does not report the
|
|
power supply information or it could not be determined."
|
|
::= { cpqRackPowerSupplyEntry 11 }
|
|
|
|
cpqRackPowerSupplyIntakeTemp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current air temperature at the intake of the power supply
|
|
in degrees celsius.
|
|
|
|
The value will be -1 if the power supply does not report the
|
|
value."
|
|
::= { cpqRackPowerSupplyEntry 12 }
|
|
|
|
cpqRackPowerSupplyExhaustTemp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current air temperature at the exhaust of the power supply
|
|
in degrees celsius.
|
|
|
|
The value will be -1 if the power supply does not report the
|
|
value."
|
|
::= { cpqRackPowerSupplyEntry 13 }
|
|
|
|
cpqRackPowerSupplyStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noError(1),
|
|
generalFailure(2),
|
|
bistFailure(3),
|
|
fanFailure(4),
|
|
tempFailure(5),
|
|
interlockOpen(6),
|
|
epromFailed(7),
|
|
vrefFailed(8),
|
|
dacFailed(9),
|
|
ramTestFailed(10),
|
|
voltageChannelFailed(11),
|
|
orringdiodeFailed(12),
|
|
brownOut(13),
|
|
giveupOnStartup(14),
|
|
nvramInvalid(15),
|
|
calibrationTableInvalid(16)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of the power supply."
|
|
::= { cpqRackPowerSupplyEntry 14 }
|
|
|
|
cpqRackPowerSupplyInputLineStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noError(1),
|
|
lineOverVoltage(2),
|
|
lineUnderVoltage(3),
|
|
lineHit(4),
|
|
brownOut(5),
|
|
linePowerLoss(6)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of line input power."
|
|
::= { cpqRackPowerSupplyEntry 15 }
|
|
|
|
cpqRackPowerSupplyPresent OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
absent(2),
|
|
present(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This specifies if the power supply described is present in the
|
|
enclosure."
|
|
::= { cpqRackPowerSupplyEntry 16 }
|
|
|
|
cpqRackPowerSupplyCondition OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
ok(2),
|
|
degraded(3),
|
|
failed(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The condition of the power supply.
|
|
|
|
This value will be one of the following:
|
|
|
|
other(1)
|
|
The status could not be determined or not present.
|
|
|
|
ok(2)
|
|
The power supply is operating normally.
|
|
|
|
degraded(3)
|
|
A temperature sensor, fan or other power supply component is
|
|
outside of normal operating range.
|
|
|
|
failed(4)
|
|
A power supply component detects a condition that could
|
|
possibly damage the system."
|
|
::= { cpqRackPowerSupplyEntry 17 }
|
|
|
|
cpqRackPowerSupplyEnclosureSerialNum OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The serial number of the power supply enclosure in which this
|
|
power supply resides.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
serial number or it could not be determined."
|
|
::= { cpqRackPowerSupplyEntry 18 }
|
|
|
|
|
|
-- ****************************************************************************
|
|
-- Rack Network Connector Table
|
|
-- ============================
|
|
--
|
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
|
-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
|
|
-- cpqRackComponent Group (1.3.6.1.4.1.232.22.2)
|
|
-- cpqRackNetwork Group (1.3.6.1.4.1.232.22.2.6)
|
|
-- cpqRackNetConnector Group (1.3.6.1.4.1.232.22.2.6.1)
|
|
-- cpqRackNetConnectorTable (1.3.6.1.4.1.232.22.2.6.1.1)
|
|
--
|
|
-- ****************************************************************************
|
|
|
|
cpqRackNetConnectorTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CpqRackNetConnectorEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of rack network connector information."
|
|
::= { cpqRackNetConnector 1 }
|
|
|
|
cpqRackNetConnectorEntry OBJECT-TYPE
|
|
SYNTAX CpqRackNetConnectorEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A rack network connector description."
|
|
INDEX { cpqRackNetConnectorRack,
|
|
cpqRackNetConnectorChassis,
|
|
cpqRackNetConnectorIndex }
|
|
::= { cpqRackNetConnectorTable 1 }
|
|
|
|
CpqRackNetConnectorEntry ::= SEQUENCE {
|
|
cpqRackNetConnectorRack INTEGER,
|
|
cpqRackNetConnectorChassis INTEGER,
|
|
cpqRackNetConnectorIndex INTEGER,
|
|
cpqRackNetConnectorEnclosureName DisplayString,
|
|
cpqRackNetConnectorName DisplayString,
|
|
cpqRackNetConnectorModel DisplayString,
|
|
cpqRackNetConnectorSerialNum DisplayString,
|
|
cpqRackNetConnectorPartNumber DisplayString,
|
|
cpqRackNetConnectorSparePartNumber DisplayString,
|
|
cpqRackNetConnectorFWRev DisplayString,
|
|
cpqRackNetConnectorType INTEGER,
|
|
cpqRackNetConnectorLocation DisplayString,
|
|
cpqRackNetConnectorPresent INTEGER,
|
|
cpqRackNetConnectorHasFuses INTEGER,
|
|
cpqRackNetConnectorEnclosureSerialNum DisplayString
|
|
}
|
|
|
|
cpqRackNetConnectorRack OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A number that uniquely specifies this rack."
|
|
::= { cpqRackNetConnectorEntry 1 }
|
|
|
|
cpqRackNetConnectorChassis OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A number that uniquely specifies this server enclosure in the rack."
|
|
::= { cpqRackNetConnectorEntry 2 }
|
|
|
|
cpqRackNetConnectorIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A number that uniquely specifies this network connector in the rack."
|
|
::= { cpqRackNetConnectorEntry 3 }
|
|
|
|
cpqRackNetConnectorEnclosureName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the network connector enclosure.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
name or it could not be determined."
|
|
::= { cpqRackNetConnectorEntry 4 }
|
|
|
|
cpqRackNetConnectorName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The name of the network connector.
|
|
|
|
The string will be empty if the network connector does not report the
|
|
name or it could not be determined."
|
|
::= { cpqRackNetConnectorEntry 5 }
|
|
|
|
cpqRackNetConnectorModel OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The model name of the network connector.
|
|
|
|
The string will be empty if the network connector does not report the
|
|
model information."
|
|
::= { cpqRackNetConnectorEntry 6 }
|
|
|
|
cpqRackNetConnectorSerialNum OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The serial number of the network connector.
|
|
|
|
The string will be empty if the network connector does not report the
|
|
serial number."
|
|
::= { cpqRackNetConnectorEntry 7 }
|
|
|
|
cpqRackNetConnectorPartNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The part number of the network connector.
|
|
|
|
The string will be empty if the enclosure does not report this
|
|
function."
|
|
::= { cpqRackNetConnectorEntry 8 }
|
|
|
|
cpqRackNetConnectorSparePartNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The spare part number of the network connector.
|
|
|
|
The string will be empty if the enclosure does not report this
|
|
function."
|
|
::= { cpqRackNetConnectorEntry 9 }
|
|
|
|
cpqRackNetConnectorFWRev OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The firmware revision of the network connector.
|
|
|
|
The string will be empty if the network connector does not report the
|
|
firmware revision."
|
|
::= { cpqRackNetConnectorEntry 10 }
|
|
|
|
cpqRackNetConnectorType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
passive(2),
|
|
active(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of network connector within the enclosure."
|
|
::= { cpqRackNetConnectorEntry 11 }
|
|
|
|
cpqRackNetConnectorLocation OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The location of the network connector within the enclosure."
|
|
::= { cpqRackNetConnectorEntry 12 }
|
|
|
|
cpqRackNetConnectorPresent OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
absent(2),
|
|
present(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This specifies if the network connector described is present in the
|
|
enclosure."
|
|
::= { cpqRackNetConnectorEntry 13 }
|
|
|
|
cpqRackNetConnectorHasFuses OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(1),
|
|
true(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The network connector contains fuses.
|
|
|
|
This will be true(2) is the network connector contains fuses.
|
|
The cpqRackCommonEnclosureFuseTable will contain the fuse
|
|
specific information.
|
|
|
|
Match the cpqRackNetworkEnclosureSerialNum in this table to the
|
|
serial number in the cpqRackCommonEnclosureFusTable to get complete
|
|
information on the fuses."
|
|
::= { cpqRackNetConnectorEntry 14 }
|
|
|
|
cpqRackNetConnectorEnclosureSerialNum OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The serial number of the enclosure containing the network connector.
|
|
|
|
The string will be empty if the enclosure does not report the
|
|
serial number or it could not be determined."
|
|
::= { cpqRackNetConnectorEntry 15 }
|
|
|
|
|
|
-- ****************************************************************************
|
|
-- Rack System Object Identification
|
|
-- =================================
|
|
--
|
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
|
-- cpqRackInfo Group (1.3.6.1.4.1.232.22)
|
|
-- cpqRackSysObjID Group (1.3.6.1.4.1.232.22.3)
|
|
--
|
|
-- ****************************************************************************
|
|
|
|
cpqRackSystemObjectIdentification OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The hardware identification string.
|
|
|
|
The string will reported by the rack firmware."
|
|
::= { cpqRackSysObjID 1 }
|
|
|
|
|
|
-- ****************************************************************************
|
|
-- Rack Information Trap Definitions
|
|
-- =================================
|
|
--
|
|
-- The SNMP trap messages must not be bigger than 484 octets (bytes).
|
|
--
|
|
-- Trap support in an SNMP agent implementation is optional. An SNMP
|
|
-- agent implementation may support all, some, or none of the traps.
|
|
-- If traps are supported, The user should be provided with the option of
|
|
-- disabling traps.
|
|
-- **************************************************************************
|
|
|
|
cpqRackNameChanged TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName,
|
|
cpqHoTrapFlags,
|
|
cpqRackName,
|
|
cpqRackUid,
|
|
cpqRackSerialNum,
|
|
cpqRackTrapSequenceNum }
|
|
DESCRIPTION
|
|
"Rack name has changed.
|
|
|
|
This trap signifies that an agent or utility has changed the name
|
|
of the rack. Each of the server blades in each of the enclosure
|
|
within the rack will be updated to reflect the new rack name.
|
|
|
|
It may take several minutes for the rack name change to be
|
|
propagated throughout the entire rack.
|
|
|
|
User Action: None."
|
|
|
|
--#TYPE "Rack name changed (22001)"
|
|
--#SUMMARY "The rack name has changed to %s."
|
|
--#ARGUMENTS {2}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
|
|
::= 22001
|
|
|
|
cpqRackEnclosureNameChanged TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName,
|
|
cpqHoTrapFlags,
|
|
cpqRackName,
|
|
cpqRackUid,
|
|
cpqRackCommonEnclosureName,
|
|
cpqRackCommonEnclosureSerialNum,
|
|
cpqRackCommonEnclosureModel,
|
|
cpqRackCommonEnclosureSparePartNumber,
|
|
cpqRackCommonEnclosureTrapSequenceNum }
|
|
DESCRIPTION
|
|
"The enclosure name has changed.
|
|
|
|
This trap signifies that an agent or utility has changed the name
|
|
of an enclosure within the rack. Each of the components
|
|
within the rack will be updated to reflect the new enclosure name.
|
|
|
|
It may take several minutes for the enclosure name change to be
|
|
propagated throughout the entire enclosure.
|
|
|
|
User Action: None."
|
|
|
|
--#TYPE "Enclosure name changed (22002)"
|
|
--#SUMMARY "The enclosure name has changed to %s in rack %s."
|
|
--#ARGUMENTS {4, 2}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
|
|
::= 22002
|
|
|
|
cpqRackEnclosureRemoved TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName,
|
|
cpqHoTrapFlags,
|
|
cpqRackName,
|
|
cpqRackUid,
|
|
cpqRackCommonEnclosureName,
|
|
cpqRackCommonEnclosureModel,
|
|
cpqRackCommonEnclosureSerialNum,
|
|
cpqRackCommonEnclosureSparePartNumber,
|
|
cpqRackCommonEnclosureTrapSequenceNum }
|
|
DESCRIPTION
|
|
"The enclosure has been removed.
|
|
|
|
This trap signifies that an enclosure has been removed from
|
|
the rack.
|
|
|
|
User Action: None."
|
|
|
|
--#TYPE "Enclosure removed (22003)"
|
|
--#SUMMARY "The enclosure %s has been removed from rack %s."
|
|
--#ARGUMENTS {4, 2}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
|
|
::= 22003
|
|
|
|
cpqRackEnclosureInserted TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName,
|
|
cpqHoTrapFlags,
|
|
cpqRackName,
|
|
cpqRackUid,
|
|
cpqRackCommonEnclosureName,
|
|
cpqRackCommonEnclosureModel,
|
|
cpqRackCommonEnclosureSerialNum,
|
|
cpqRackCommonEnclosureSparePartNumber,
|
|
cpqRackCommonEnclosureTrapSequenceNum }
|
|
DESCRIPTION
|
|
"The enclosure has been inserted.
|
|
|
|
This trap signifies that an enclosure has been inserted into
|
|
the rack.
|
|
|
|
User Action: None."
|
|
|
|
--#TYPE "Enclosure inserted (22004)"
|
|
--#SUMMARY "The enclosure %s has been inserted into rack %s."
|
|
--#ARGUMENTS {4, 2}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
|
|
::= 22004
|
|
|
|
cpqRackEnclosureTempFailed TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName,
|
|
cpqHoTrapFlags,
|
|
cpqRackName,
|
|
cpqRackUid,
|
|
cpqRackCommonEnclosureName,
|
|
cpqRackCommonEnclosureSerialNum,
|
|
cpqRackCommonEnclosureTempLocation,
|
|
cpqRackCommonEnclosureSparePartNumber,
|
|
cpqRackCommonEnclosureTrapSequenceNum }
|
|
DESCRIPTION
|
|
"The enclosure temperature status has been set to failed.
|
|
|
|
This trap signifies that a enclosure temperature sensor has
|
|
been tripped indicating an overheat condition.
|
|
|
|
User Action: Shutdown the enclosure and possibly the rack
|
|
as soon as possible. Insure all fans are working properly and
|
|
that air flow in the rack has not been blocked."
|
|
|
|
--#TYPE "Enclosure temperature failed (22005)"
|
|
--#SUMMARY "The enclosure %s temperature sensor in rack %s has been set to failed."
|
|
--#ARGUMENTS {4, 2}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 99
|
|
--#STATE NONOPERATIONAL
|
|
|
|
::= 22005
|
|
|
|
cpqRackEnclosureTempDegraded TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName,
|
|
cpqHoTrapFlags,
|
|
cpqRackName,
|
|
cpqRackUid,
|
|
cpqRackCommonEnclosureName,
|
|
cpqRackCommonEnclosureSerialNum,
|
|
cpqRackCommonEnclosureTempLocation,
|
|
cpqRackCommonEnclosureSparePartNumber,
|
|
cpqRackCommonEnclosureTrapSequenceNum }
|
|
DESCRIPTION
|
|
"The enclosure temperature status has been set to degraded.
|
|
|
|
This trap signifies that an enclosure temperature sensor has
|
|
been tripped indicating a possible overheat condition.
|
|
|
|
User Action: Shutdown the enclosure and possibly the rack
|
|
as soon as possible. Insure all fans are working properly and
|
|
that air flow in the rack has not been blocked."
|
|
|
|
--#TYPE "Enclosure temperature degraded (22006)"
|
|
--#SUMMARY "The enclosure %s temperature sensor in rack %s has been set to degraded."
|
|
--#ARGUMENTS {4, 2}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
|
|
::= 22006
|
|
|
|
cpqRackEnclosureTempOk TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName,
|
|
cpqHoTrapFlags,
|
|
cpqRackName,
|
|
cpqRackUid,
|
|
cpqRackCommonEnclosureName,
|
|
cpqRackCommonEnclosureSerialNum,
|
|
cpqRackCommonEnclosureTempLocation,
|
|
cpqRackCommonEnclosureSparePartNumber,
|
|
cpqRackCommonEnclosureTrapSequenceNum }
|
|
DESCRIPTION
|
|
"The enclosure temperature status has been set to ok.
|
|
|
|
This trap signifies that an enclosure temperature sensor has
|
|
returned to normal.
|
|
|
|
User Action: None."
|
|
|
|
--#TYPE "Enclosure temperature ok (22007)"
|
|
--#SUMMARY "The enclosure %s temperature sensor in rack %s has been set to ok."
|
|
--#ARGUMENTS {4, 2}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
|
|
::= 22007
|
|
|
|
cpqRackEnclosureFanFailed TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName,
|
|
cpqHoTrapFlags,
|
|
cpqRackName,
|
|
cpqRackUid,
|
|
cpqRackCommonEnclosureName,
|
|
cpqRackCommonEnclosureSerialNum,
|
|
cpqRackCommonEnclosureFanLocation,
|
|
cpqRackCommonEnclosureFanSparePartNumber,
|
|
cpqRackCommonEnclosureTrapSequenceNum }
|
|
DESCRIPTION
|
|
"The enclosure fan status has been set to failed.
|
|
|
|
This trap signifies that an enclosure fan has failed and
|
|
no other fans in the redundant fan group are operating.
|
|
This may result in overheating of the enclosure.
|
|
|
|
User Action: Replace the fan as soon as possible."
|
|
|
|
--#TYPE "Enclosure fan failed (22008)"
|
|
--#SUMMARY "The enclosure %s fan in rack %s has been set to failed."
|
|
--#ARGUMENTS {4, 2}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 99
|
|
--#STATE NONOPERATIONAL
|
|
|
|
::= 22008
|
|
|
|
cpqRackEnclosureFanDegraded TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName,
|
|
cpqHoTrapFlags,
|
|
cpqRackName,
|
|
cpqRackUid,
|
|
cpqRackCommonEnclosureName,
|
|
cpqRackCommonEnclosureSerialNum,
|
|
cpqRackCommonEnclosureFanLocation,
|
|
cpqRackCommonEnclosureFanSparePartNumber,
|
|
cpqRackCommonEnclosureTrapSequenceNum }
|
|
DESCRIPTION
|
|
"The enclosure fan status has been set to degraded.
|
|
|
|
This trap signifies that an enclosure fan has failed but
|
|
other fans in the redundant fan group are still operating.
|
|
This may result in overheating of the enclosure.
|
|
|
|
User Action: Replace the fan as soon as possible."
|
|
|
|
--#TYPE "Enclosure fan degraded (22009)"
|
|
--#SUMMARY "The enclosure %s fan in rack %s has been set to degraded."
|
|
--#ARGUMENTS {4, 2}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
|
|
::= 22009
|
|
|
|
cpqRackEnclosureFanOk TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName,
|
|
cpqHoTrapFlags,
|
|
cpqRackName,
|
|
cpqRackUid,
|
|
cpqRackCommonEnclosureName,
|
|
cpqRackCommonEnclosureSerialNum,
|
|
cpqRackCommonEnclosureFanLocation,
|
|
cpqRackCommonEnclosureFanSparePartNumber,
|
|
cpqRackCommonEnclosureTrapSequenceNum }
|
|
DESCRIPTION
|
|
"The enclosure fan status has been set to ok.
|
|
|
|
This trap signifies that an enclosure fan has returned
|
|
to normal operation.
|
|
|
|
User Action: None."
|
|
|
|
--#TYPE "Enclosure fan ok (22010)"
|
|
--#SUMMARY "The enclosure %s fan in rack %s has been set to ok."
|
|
--#ARGUMENTS {4, 2}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
|
|
::= 22010
|
|
|
|
|
|
cpqRackEnclosureFanRemoved TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName,
|
|
cpqHoTrapFlags,
|
|
cpqRackName,
|
|
cpqRackUid,
|
|
cpqRackCommonEnclosureName,
|
|
cpqRackCommonEnclosureSerialNum,
|
|
cpqRackCommonEnclosureFanLocation,
|
|
cpqRackCommonEnclosureFanSparePartNumber,
|
|
cpqRackCommonEnclosureTrapSequenceNum }
|
|
DESCRIPTION
|
|
"The enclosure fan has been removed.
|
|
|
|
User Action: None."
|
|
|
|
--#TYPE "Enclosure fan removed (22011)"
|
|
--#SUMMARY "The enclosure %s fan in rack %s has been removed."
|
|
--#ARGUMENTS {4, 2}
|
|
--#SEVERITY MINOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
|
|
::= 22011
|
|
|
|
cpqRackEnclosureFanInserted TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName,
|
|
cpqHoTrapFlags,
|
|
cpqRackName,
|
|
cpqRackUid,
|
|
cpqRackCommonEnclosureName,
|
|
cpqRackCommonEnclosureSerialNum,
|
|
cpqRackCommonEnclosureFanLocation,
|
|
cpqRackCommonEnclosureFanSparePartNumber,
|
|
cpqRackCommonEnclosureTrapSequenceNum }
|
|
DESCRIPTION
|
|
"The enclosure fan has been inserted.
|
|
|
|
User Action: None."
|
|
|
|
--#TYPE "Enclosure fan inserted (22012)"
|
|
--#SUMMARY "The enclosure %s fan in rack %s has been inserted."
|
|
--#ARGUMENTS {4, 2}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
|
|
::= 22012
|
|
|
|
cpqRackPowerSupplyFailed TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName,
|
|
cpqHoTrapFlags,
|
|
cpqRackName,
|
|
cpqRackUid,
|
|
cpqRackPowerSupplyEnclosureName,
|
|
cpqRackPowerSupplySerialNum,
|
|
cpqRackPowerSupplyPosition,
|
|
cpqRackPowerSupplyFWRev,
|
|
cpqRackPowerSupplySparePartNumber,
|
|
cpqRackCommonEnclosureSerialNum,
|
|
cpqRackCommonEnclosureTrapSequenceNum }
|
|
DESCRIPTION
|
|
"The power supply status has been set to failed.
|
|
|
|
This trap signifies that a power supply has failed.
|
|
|
|
User Action: Replace the power supply as soon as possible."
|
|
|
|
--#TYPE "Rack power supply failed (22013)"
|
|
--#SUMMARY "The power supply %s in enclosure %s in rack %s has been set to failed."
|
|
--#ARGUMENTS {6, 4, 2}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 99
|
|
--#STATE NONOPERATIONAL
|
|
|
|
::= 22013
|
|
|
|
cpqRackPowerSupplyDegraded TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName,
|
|
cpqHoTrapFlags,
|
|
cpqRackName,
|
|
cpqRackUid,
|
|
cpqRackPowerSupplyEnclosureName,
|
|
cpqRackPowerSupplySerialNum,
|
|
cpqRackPowerSupplyPosition,
|
|
cpqRackPowerSupplyFWRev,
|
|
cpqRackPowerSupplySparePartNumber,
|
|
cpqRackCommonEnclosureSerialNum,
|
|
cpqRackCommonEnclosureTrapSequenceNum }
|
|
DESCRIPTION
|
|
"The power supply status has been set to degraded.
|
|
|
|
This trap signifies that a power supply has degraded.
|
|
|
|
User Action: Replace the power supply as soon as possible."
|
|
|
|
--#TYPE "Rack power supply degraded (22014)"
|
|
--#SUMMARY "The power supply %s in enclosure %s in rack %s has been set to degraded."
|
|
--#ARGUMENTS {6, 4, 2}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
|
|
::= 22014
|
|
|
|
cpqRackPowerSupplyOk TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName,
|
|
cpqHoTrapFlags,
|
|
cpqRackName,
|
|
cpqRackUid,
|
|
cpqRackPowerSupplyEnclosureName,
|
|
cpqRackPowerSupplySerialNum,
|
|
cpqRackPowerSupplyPosition,
|
|
cpqRackPowerSupplyFWRev,
|
|
cpqRackPowerSupplySparePartNumber,
|
|
cpqRackCommonEnclosureSerialNum,
|
|
cpqRackCommonEnclosureTrapSequenceNum }
|
|
DESCRIPTION
|
|
"The power supply status has been set to ok.
|
|
|
|
This trap signifies that a power supply has returned to normal
|
|
operation.
|
|
|
|
User Action: None."
|
|
|
|
--#TYPE "Rack power supply ok (22015)"
|
|
--#SUMMARY "The power supply %s in enclosure %s in rack %s has been set to ok."
|
|
--#ARGUMENTS {6, 4, 2}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
|
|
::= 22015
|
|
|
|
cpqRackPowerSupplyRemoved TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName,
|
|
cpqHoTrapFlags,
|
|
cpqRackName,
|
|
cpqRackUid,
|
|
cpqRackPowerSupplyEnclosureName,
|
|
cpqRackPowerSupplySerialNum,
|
|
cpqRackPowerSupplyPosition,
|
|
cpqRackPowerSupplyFWRev,
|
|
cpqRackPowerSupplySparePartNumber,
|
|
cpqRackCommonEnclosureSerialNum,
|
|
cpqRackCommonEnclosureTrapSequenceNum }
|
|
DESCRIPTION
|
|
"The power supply has been removed.
|
|
|
|
User Action: None."
|
|
|
|
--#TYPE "Rack power supply removed (22016)"
|
|
--#SUMMARY "The power supply %s in enclosure %s in rack %s has been removed."
|
|
--#ARGUMENTS {6, 4, 2}
|
|
--#SEVERITY MINOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
|
|
::= 22016
|
|
|
|
cpqRackPowerSupplyInserted TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName,
|
|
cpqHoTrapFlags,
|
|
cpqRackName,
|
|
cpqRackUid,
|
|
cpqRackPowerSupplyEnclosureName,
|
|
cpqRackPowerSupplySerialNum,
|
|
cpqRackPowerSupplyPosition,
|
|
cpqRackPowerSupplyFWRev,
|
|
cpqRackPowerSupplySparePartNumber,
|
|
cpqRackCommonEnclosureSerialNum,
|
|
cpqRackCommonEnclosureTrapSequenceNum }
|
|
DESCRIPTION
|
|
"The power supply has been inserted.
|
|
|
|
User Action: None."
|
|
|
|
--#TYPE "Rack power supply inserted (22017)"
|
|
--#SUMMARY "The power supply %s in enclosure %s in rack %s has been inserted."
|
|
--#ARGUMENTS {6, 4, 2}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
|
|
::= 22017
|
|
|
|
cpqRackPowerSubsystemNotRedundant TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName,
|
|
cpqHoTrapFlags,
|
|
cpqRackName,
|
|
cpqRackUid,
|
|
cpqRackPowerEnclosureName,
|
|
cpqRackCommonEnclosureSerialNum,
|
|
cpqRackCommonEnclosureTrapSequenceNum }
|
|
DESCRIPTION
|
|
"The rack power subsystem is no longer in a redundant state.
|
|
|
|
User Action: Replace any failed power supplies as soon as possible
|
|
to return the system to a redundant state."
|
|
|
|
--#TYPE "Rack power subsystem not redundant (22018)"
|
|
--#SUMMARY "The power subsystem in enclosure %s in rack %s is no longer redundant."
|
|
--#ARGUMENTS {4, 2}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
|
|
::= 22018
|
|
|
|
cpqRackPowerSubsystemLineVoltageProblem TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName,
|
|
cpqHoTrapFlags,
|
|
cpqRackName,
|
|
cpqRackUid,
|
|
cpqRackPowerSupplyEnclosureName,
|
|
cpqRackPowerSupplyPosition,
|
|
cpqRackPowerSupplyFWRev,
|
|
cpqRackPowerSupplyInputLineStatus,
|
|
cpqRackPowerSupplySparePartNumber,
|
|
cpqRackCommonEnclosureSerialNum,
|
|
cpqRackCommonEnclosureTrapSequenceNum }
|
|
DESCRIPTION
|
|
"The rack power supply detected an input line voltage problem.
|
|
|
|
User Action: Check the power input for the power supply or replace
|
|
any failed power supplies as soon as possible."
|
|
|
|
--#TYPE "Rack power supply input voltage problem (22019)"
|
|
--#SUMMARY "The rack power supply detected an input line voltage problem in power supply %s, enclosure %s, rack %s."
|
|
--#ARGUMENTS {5, 4, 2}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
|
|
::= 22019
|
|
|
|
cpqRackPowerSubsystemOverloadCondition TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName,
|
|
cpqHoTrapFlags,
|
|
cpqRackName,
|
|
cpqRackUid,
|
|
cpqRackPowerEnclosureName,
|
|
cpqRackCommonEnclosureSparePartNumber,
|
|
cpqRackCommonEnclosureSerialNum,
|
|
cpqRackCommonEnclosureTrapSequenceNum }
|
|
DESCRIPTION
|
|
"The rack power subsystem overload condition.
|
|
|
|
User Action: Replace any failed power supplies as soon as possible
|
|
to return the system to a redundant state."
|
|
|
|
--#TYPE "Rack power subsystem overload condition (22020)"
|
|
--#SUMMARY "The power subsystem in enclosure %s in rack %s is in an overload condition."
|
|
--#ARGUMENTS {4, 2}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
|
|
::= 22020
|
|
|
|
cpqRackPowerShedAutoShutdown TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName,
|
|
cpqHoTrapFlags,
|
|
cpqRackName,
|
|
cpqRackUid,
|
|
cpqRackServerBladeEnclosureName,
|
|
cpqRackServerBladePosition,
|
|
cpqRackServerBladeSparePartNumber,
|
|
cpqRackCommonEnclosureSerialNum,
|
|
cpqRackCommonEnclosureTrapSequenceNum }
|
|
DESCRIPTION
|
|
"Server shutdown due to power shedding.
|
|
|
|
The server blade was shutdown due to a lack of power.
|
|
|
|
User Action: Check power connections or add power supplies."
|
|
|
|
--#TYPE "Server shutdown due to power shedding (22021)"
|
|
--#SUMMARY "The server shutdown due to lack of power blade %s, in enclosure %s, in rack %s."
|
|
--#ARGUMENTS {5, 4, 2}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 99
|
|
--#STATE NONOPERATIONAL
|
|
|
|
::= 22021
|
|
|
|
cpqRackServerPowerOnFailedNotRedundant TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName,
|
|
cpqHoTrapFlags,
|
|
cpqRackName,
|
|
cpqRackUid,
|
|
cpqRackServerBladeEnclosureName,
|
|
cpqRackServerBladePosition,
|
|
cpqRackServerBladeSparePartNumber,
|
|
cpqRackCommonEnclosureSerialNum,
|
|
cpqRackCommonEnclosureTrapSequenceNum }
|
|
DESCRIPTION
|
|
"Server power on prevented to preserve redundancy.
|
|
|
|
There is not enough power to power on the server blade and
|
|
maintain redundancy for the other blades in the enclosure.
|
|
|
|
User Action: Check power connections or add power supplies."
|
|
|
|
--#TYPE "Server power on prevented to preserve redundancy (22022)"
|
|
--#SUMMARY "Server power on prevented to preserve redundancy in blade %s, in enclosure %s, in rack %s."
|
|
--#ARGUMENTS {5, 4, 2}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 99
|
|
--#STATE NONOPERATIONAL
|
|
|
|
::= 22022
|
|
|
|
cpqRackServerPowerOnFailedNotEnoughPower TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName,
|
|
cpqHoTrapFlags,
|
|
cpqRackName,
|
|
cpqRackUid,
|
|
cpqRackServerBladeEnclosureName,
|
|
cpqRackServerBladePosition,
|
|
cpqRackServerBladeSparePartNumber,
|
|
cpqRackCommonEnclosureSerialNum,
|
|
cpqRackCommonEnclosureTrapSequenceNum }
|
|
DESCRIPTION
|
|
"Inadequate power to power on.
|
|
|
|
There is not enough power to power on the server blade.
|
|
|
|
User Action: Check power connections or add power supplies."
|
|
|
|
--#TYPE "Inadequate power to power on (22023)"
|
|
--#SUMMARY "Inadequate power to power on blade %s, in enclosure %s, in rack %s."
|
|
--#ARGUMENTS {5, 4, 2}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 99
|
|
--#STATE NONOPERATIONAL
|
|
|
|
::= 22023
|
|
|
|
cpqRackServerPowerOnFailedEnclosureNotFound TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName,
|
|
cpqHoTrapFlags,
|
|
cpqRackName,
|
|
cpqRackUid,
|
|
cpqRackServerBladeEnclosureName,
|
|
cpqRackServerBladePosition,
|
|
cpqRackServerBladeSparePartNumber,
|
|
cpqRackCommonEnclosureSerialNum,
|
|
cpqRackCommonEnclosureTrapSequenceNum }
|
|
DESCRIPTION
|
|
"Inadequate power to power on.
|
|
|
|
There is not enough power to power on the server blade. The
|
|
server enclosure micro-controller was not found.
|
|
|
|
User Action: Check server enclosure connections or add power supplies."
|
|
|
|
--#TYPE "Inadequate power to power on (22024)"
|
|
--#SUMMARY "Inadequate power to power on blade %s, in enclosure %s, in rack %s."
|
|
--#ARGUMENTS {5, 4, 2}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 99
|
|
--#STATE NONOPERATIONAL
|
|
|
|
::= 22024
|
|
|
|
cpqRackServerPowerOnFailedPowerChassisNotFound TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName,
|
|
cpqHoTrapFlags,
|
|
cpqRackName,
|
|
cpqRackUid,
|
|
cpqRackServerBladeEnclosureName,
|
|
cpqRackServerBladePosition,
|
|
cpqRackServerBladeSparePartNumber,
|
|
cpqRackCommonEnclosureSerialNum,
|
|
cpqRackCommonEnclosureTrapSequenceNum }
|
|
DESCRIPTION
|
|
"Inadequate power to power on.
|
|
|
|
There is not enough power to power on the server blade. The
|
|
power enclosure micro-controller was not found.
|
|
|
|
User Action: Check power enclosure connections or add power supplies."
|
|
|
|
--#TYPE "Inadequate power to power on (22025)"
|
|
--#SUMMARY "Inadequate power to power on blade %s, in enclosure %s, in rack %s."
|
|
--#ARGUMENTS {5, 4, 2}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 99
|
|
--#STATE NONOPERATIONAL
|
|
|
|
::= 22025
|
|
|
|
cpqRackServerPowerOnManualOverride TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName,
|
|
cpqHoTrapFlags,
|
|
cpqRackName,
|
|
cpqRackUid,
|
|
cpqRackServerBladeEnclosureName,
|
|
cpqRackServerBladePosition,
|
|
cpqRackServerBladeSparePartNumber,
|
|
cpqRackCommonEnclosureSerialNum,
|
|
cpqRackCommonEnclosureTrapSequenceNum }
|
|
DESCRIPTION
|
|
"Server power on via manual override.
|
|
|
|
The server blade was powered on by a manual override.
|
|
|
|
User Action: None."
|
|
|
|
--#TYPE "Server power on via manual override (22026)"
|
|
--#SUMMARY "Server power on via manual override on blade %s, in enclosure %s, in rack %s."
|
|
--#ARGUMENTS {5, 4, 2}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
|
|
::= 22026
|
|
|
|
cpqRackFuseOpen TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName,
|
|
cpqHoTrapFlags,
|
|
cpqRackName,
|
|
cpqRackUid,
|
|
cpqRackCommonEnclosureName,
|
|
cpqRackCommonEnclosureFuseLocation,
|
|
cpqRackCommonEnclosureSparePartNumber,
|
|
cpqRackCommonEnclosureSerialNum,
|
|
cpqRackCommonEnclosureTrapSequenceNum }
|
|
DESCRIPTION
|
|
"Fuse open.
|
|
|
|
The fuse has been tripped.
|
|
|
|
User Action: Check enclosure and / or blade power connections and
|
|
reset the fuse."
|
|
|
|
--#TYPE "Fuse open (22027)"
|
|
--#SUMMARY "Fuse open fuse %s, in enclosure %s, in rack %s."
|
|
--#ARGUMENTS {5, 4, 2}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
|
|
::= 22027
|
|
|
|
|
|
cpqRackServerBladeRemoved TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName,
|
|
cpqHoTrapFlags,
|
|
cpqRackName,
|
|
cpqRackUid,
|
|
cpqRackServerBladeEnclosureName,
|
|
cpqRackServerBladeName,
|
|
cpqRackServerBladePosition,
|
|
cpqRackServerBladeSparePartNumber,
|
|
cpqRackCommonEnclosureSerialNum,
|
|
cpqRackCommonEnclosureTrapSequenceNum }
|
|
DESCRIPTION
|
|
"Server blade removed.
|
|
|
|
The server blade has been removed from the enclosure.
|
|
|
|
User Action: None."
|
|
|
|
--#TYPE "Server blade removed (22028)"
|
|
--#SUMMARY "Server blade %s removed from position %s, in enclosure %s, in rack %s."
|
|
--#ARGUMENTS {5, 6, 4, 2}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
|
|
::= 22028
|
|
|
|
cpqRackServerBladeInserted TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName,
|
|
cpqHoTrapFlags,
|
|
cpqRackName,
|
|
cpqRackUid,
|
|
cpqRackServerBladeEnclosureName,
|
|
cpqRackServerBladeName,
|
|
cpqRackServerBladePosition,
|
|
cpqRackServerBladeSparePartNumber,
|
|
cpqRackCommonEnclosureSerialNum,
|
|
cpqRackCommonEnclosureTrapSequenceNum }
|
|
DESCRIPTION
|
|
"Server blade inserted.
|
|
|
|
The server blade has been inserted into the enclosure.
|
|
|
|
User Action: None."
|
|
|
|
--#TYPE "Server blade inserted (22029)"
|
|
--#SUMMARY "Server blade %s inserted into position %s, in enclosure %s, in rack %s."
|
|
--#ARGUMENTS {5, 6, 4, 2}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
|
|
::= 22029
|
|
|
|
cpqRackPowerChassisNotLoadBalanced TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName,
|
|
cpqHoTrapFlags,
|
|
cpqRackName,
|
|
cpqRackUid,
|
|
cpqRackCommonEnclosureName,
|
|
cpqRackCommonEnclosureSerialNum,
|
|
cpqRackCommonEnclosureSparePartNumber,
|
|
cpqRackCommonEnclosureTrapSequenceNum }
|
|
DESCRIPTION
|
|
"Power subsystem not load balanced.
|
|
|
|
The power subsystem is out of balance for this power enclosure.
|
|
|
|
User Action: Check the power enclosure and power supplies. Replace
|
|
any failed or degraded power supplies. Add additional power supplies
|
|
if needed."
|
|
|
|
--#TYPE "Power subsystem not load balanced (22030)"
|
|
--#SUMMARY "Power subsystem not load balanced in enclosure %s, in rack %s."
|
|
--#ARGUMENTS {4, 2}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
|
|
::= 22030
|
|
|
|
cpqRackPowerChassisDcPowerProblem TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName,
|
|
cpqHoTrapFlags,
|
|
cpqRackName,
|
|
cpqRackUid,
|
|
cpqRackCommonEnclosureName,
|
|
cpqRackCommonEnclosureSerialNum,
|
|
cpqRackCommonEnclosureSparePartNumber,
|
|
cpqRackCommonEnclosureTrapSequenceNum }
|
|
DESCRIPTION
|
|
"Power subsystem DC power problem.
|
|
|
|
There is a power subsystem DC power problem for this power enclosure.
|
|
|
|
User Action: Check the power enclosure and power supplies. Replace
|
|
any failed or degraded power supplies."
|
|
|
|
--#TYPE "Power subsystem DC power problem (22031)"
|
|
--#SUMMARY "Power subsystem DC power problem in enclosure %s, in rack %s."
|
|
--#ARGUMENTS {4, 2}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
|
|
::= 22031
|
|
|
|
cpqRackPowerChassisAcFacilityPowerExceeded TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName,
|
|
cpqHoTrapFlags,
|
|
cpqRackName,
|
|
cpqRackUid,
|
|
cpqRackCommonEnclosureName,
|
|
cpqRackCommonEnclosureSerialNum,
|
|
cpqRackCommonEnclosureSparePartNumber,
|
|
cpqRackCommonEnclosureTrapSequenceNum }
|
|
DESCRIPTION
|
|
"Power subsystem AC facility input power exceeded.
|
|
|
|
There is a power subsystem Power subsystem AC facility input power
|
|
exceeded for this power enclosure.
|
|
|
|
User Action: Check the power enclosure and power supplies. Replace
|
|
any failed or degraded power supplies."
|
|
|
|
--#TYPE "Power subsystem AC facility input power exceeded (22032)"
|
|
--#SUMMARY "Power subsystem AC facility input power exceeded in enclosure %s, in rack %s."
|
|
--#ARGUMENTS {4, 2}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
|
|
::= 22032
|
|
|
|
|
|
|
|
cpqRackPowerUnknownPowerConsumption TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName,
|
|
cpqHoTrapFlags,
|
|
cpqRackName,
|
|
cpqRackUid,
|
|
cpqRackCommonEnclosureSerialNum,
|
|
cpqRackCommonEnclosureTrapSequenceNum }
|
|
DESCRIPTION
|
|
"Unknown power consumption.
|
|
|
|
There is an unknown power consumer drawing power.
|
|
|
|
User Action: Check the power enclosure and power supplies. Replace
|
|
any failed or degraded power supplies."
|
|
|
|
--#TYPE "Unknown power consumption (22033)"
|
|
--#SUMMARY "Unknown power consumption in rack %s."
|
|
--#ARGUMENTS {2}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
|
|
::= 22033
|
|
|
|
cpqRackPowerChassisLoadBalancingWireMissing TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName,
|
|
cpqHoTrapFlags,
|
|
cpqRackName,
|
|
cpqRackUid,
|
|
cpqRackCommonEnclosureName,
|
|
cpqRackCommonEnclosureSerialNum,
|
|
cpqRackCommonEnclosureSparePartNumber,
|
|
cpqRackCommonEnclosureTrapSequenceNum }
|
|
DESCRIPTION
|
|
"Power subsystem load balancing wire missing.
|
|
|
|
The power subsystem load balancing wire missing.
|
|
|
|
User Action: Connect the load balancing wire."
|
|
|
|
--#TYPE "Power subsystem load balancing wire missing (22034)"
|
|
--#SUMMARY "Power subsystem load balancing wire missing for enclosure %s, in rack %s."
|
|
--#ARGUMENTS {4, 2}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
|
|
::= 22034
|
|
|
|
cpqRackPowerChassisTooManyPowerChassis TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName,
|
|
cpqHoTrapFlags,
|
|
cpqRackName,
|
|
cpqRackUid,
|
|
cpqRackCommonEnclosureName,
|
|
cpqRackCommonEnclosureSerialNum,
|
|
cpqRackCommonEnclosureTrapSequenceNum }
|
|
DESCRIPTION
|
|
"Power subsystem has too may power enclosures.
|
|
|
|
The maximum number of power enclosures has been exceeded.
|
|
|
|
User Action: Remove the extra power enclosure."
|
|
|
|
--#TYPE "Power subsystem has too may power enclosures (22035)"
|
|
--#SUMMARY "Power subsystem has too may power enclosures %s, in rack %s."
|
|
--#ARGUMENTS {4, 2}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
|
|
::= 22035
|
|
|
|
cpqRackPowerChassisConfigError TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName,
|
|
cpqHoTrapFlags,
|
|
cpqRackName,
|
|
cpqRackUid,
|
|
cpqRackCommonEnclosureName,
|
|
cpqRackCommonEnclosureSerialNum,
|
|
cpqRackCommonEnclosureSparePartNumber,
|
|
cpqRackCommonEnclosureTrapSequenceNum }
|
|
DESCRIPTION
|
|
"Power subsystem improperly configured.
|
|
|
|
The power subsystem has been improperly configured.
|
|
|
|
User Action: Check the cabling of the power enclosure."
|
|
|
|
--#TYPE "Power subsystem improperly configured (22036)"
|
|
--#SUMMARY "Power subsystem has been improperly configured in enclosure %s, in rack %s."
|
|
--#ARGUMENTS {4, 2}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
|
|
::= 22036
|
|
|
|
END
|
|
|