PDU2-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE FROM SNMPv2-SMI
|
|
enterprises, Integer32, Unsigned32, IpAddress FROM SNMPv2-SMI
|
|
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF
|
|
TEXTUAL-CONVENTION, DisplayString, MacAddress, TruthValue, RowPointer FROM SNMPv2-TC
|
|
InetAddressType, InetAddress, InetPortNumber FROM INET-ADDRESS-MIB
|
|
sysContact, sysName, sysLocation FROM RFC1213-MIB;
|
|
|
|
|
|
raritan MODULE-IDENTITY
|
|
LAST-UPDATED "201406040000Z" -- June 04, 2014
|
|
ORGANIZATION "Raritan"
|
|
CONTACT-INFO "
|
|
Author: Raritan Americas, Inc.
|
|
postal: Raritan Americas, Inc.
|
|
400 Cottontail Lane
|
|
Somerset, NJ 08873
|
|
email: tech@raritan.com
|
|
phone: +1 732 764 8886
|
|
"
|
|
DESCRIPTION "This MIB describes the SNMP functions of the Dominion PX G2
|
|
Power Distribution Unit by Raritan Computer."
|
|
|
|
|
|
REVISION "201406040000Z" -- June 04, 2014
|
|
|
|
DESCRIPTION "PX2 release 3.0.0:
|
|
- Support for signed sensor readings
|
|
- Support for unit-level power and energy sensors
|
|
- Send trap on peripheral device firmware update
|
|
- Allow peripheral device auto management to be disabled
|
|
- Allow front panel outlet switching to be enabled or disabled
|
|
- Support DX-PIR occupancy sensor
|
|
|
|
1) Changed the SYNTAX from Integer32 to Unsigned32:
|
|
measurementsUnitSensorValue
|
|
2) Added signed value, range and threshold columns to:
|
|
unitSensorConfigurationTable
|
|
unitSensorMeasurementsTable
|
|
pduSensorStateChange
|
|
inletSensorConfigurationTable
|
|
inletSensorMeasurementsTable
|
|
inletSensorLogTable
|
|
inletSensorStateChange
|
|
inletPoleSensorConfigurationTable
|
|
inletPoleSensorMeasurementsTable
|
|
inletPoleSensorLogTable
|
|
inletPoleSensorStateChange
|
|
overCurrentProtectorSensorConfigurationTable
|
|
overCurrentProtectorSensorMeasurementsTable
|
|
overCurrentProtectorSensorLogTable
|
|
overCurrentProtectorSensorStateChange
|
|
outletSensorConfigurationTable
|
|
outletSensorMeasurementsTable
|
|
outletSensorLogTable
|
|
outletSensorStateChange
|
|
outletPoleSensorConfigurationTable
|
|
outletPoleSensorMeasurementsTable
|
|
outletPoleSensorLogTable
|
|
outletPoleSensorStateChange
|
|
3) Added unsigned value, range and threshold columns to:
|
|
unitSensorLogTable
|
|
transferSwitchSensorConfigurationTable
|
|
transferSwitchSensorMeasurementsTable
|
|
transferSwitchSensorLogTable
|
|
transferSwitchSensorStateChange
|
|
4) Added UnitSensorControlTable
|
|
5) Added unitSensorReset and unitSensorStateChange traps
|
|
6) Deprecated pduSensorStateChange trap
|
|
7) Added to unitConfigurationTable:
|
|
peripheralDevicesAutoManagement
|
|
frontPanelOutletSwitching
|
|
frontPanelRCMSelfTest
|
|
frontPanelActuatorControl
|
|
8) Added to externalSensorConfigurationTable:
|
|
externalSensorAlarmedToNormalDelay
|
|
9) Deprecated:
|
|
wireCount in unitConfiguraionTable
|
|
tables for wireSensors
|
|
traps for wireSensors
|
|
10) SensorStateEnumeration: Added
|
|
fail(14)
|
|
11) ProductTypeEnumeration: Renamed
|
|
rackSts(2) to transferSwitch
|
|
12) Added:
|
|
PeripheralDeviceFirmwareUpdateStateEnumeration
|
|
peripheralDeviceFirmwareUpdateState
|
|
peripheralDeviceFirmwareUpdate trap
|
|
13) Added userName to the following traps:
|
|
bulkConfigurationSaved
|
|
bulkConfigurationCopied
|
|
lhxSupportChanged
|
|
deviceSettingsSaved
|
|
deviceSettingsRestored
|
|
"
|
|
|
|
|
|
REVISION "201401090000Z" -- January 9, 2014
|
|
|
|
DESCRIPTION "PX2 release 2.6.0:
|
|
- Support for PX3TS transfer switches
|
|
|
|
1) SensorTypeEnumeration:
|
|
Removed:
|
|
scrOpenStatus
|
|
scrShortStatus
|
|
Added:
|
|
i1SmpsStatus(46)
|
|
i2SmpsStatus(47)
|
|
switchStatus(48)
|
|
2) SensorStateEnumeration:
|
|
Removed:
|
|
marginal
|
|
fail
|
|
Added:
|
|
i1OpenFault(22)
|
|
i1ShortFault(23)
|
|
i2OpenFault(24)
|
|
i2ShortFault(25)
|
|
fault(26)
|
|
warning(27)
|
|
critical(28)
|
|
3) unitDeviceCapabilities: Added
|
|
i1SmpsStatus(45)
|
|
i2SmpsStatus(46)
|
|
4) transferSwitchCapabilities: Added
|
|
switchStatus(47)
|
|
5) Added transferSwitchConfiguration table
|
|
6) unitSensorLogTable:
|
|
Removed:
|
|
logUnitSensorAvgValue
|
|
logUnitSensorMaxValue
|
|
logUnitSensorMinValue
|
|
Added:
|
|
logUnitSensorSignedAvgValue
|
|
logUnitSensorSignedMaxValue
|
|
logUnitSensorSignedMinValue
|
|
"
|
|
|
|
|
|
REVISION "201401070000Z" -- January 7, 2014
|
|
|
|
DESCRIPTION "PX2 release 2.5.30:
|
|
- Accumulating sensors (energy counters) can be reset
|
|
- Sensor accuray and tolerance variables are deprecated
|
|
|
|
1) Added peripheralDevicePackagePosition and peripheralDevicePackageState
|
|
2) Added radiusError trap
|
|
3) Added serverReachabilityError trap
|
|
4) Deprecated the following:
|
|
unitSensorConfigurationTable/unitSensorAccuracy
|
|
unitSensorConfigurationTable/unitSensorTolerance
|
|
inletSensorConfigurationTable/inletSensorAccuracy
|
|
inletSensorConfigurationTable/inletSensorTolerance
|
|
inletPoleSensorConfigurationTable/inletPoleSensorAccuracy
|
|
inletPoleSensorConfigurationTable/inletPoleSensorTolerance
|
|
outletSensorConfigurationTable/outetSensorAccuracy
|
|
outletSensorConfigurationTable/outletSensorTolerance
|
|
outletPoleSensorConfigurationTable/outetPoleSensorAccuracy
|
|
outletPoleSensorConfigurationTable/outletPoleSensorTolerance
|
|
overCurrentProtectorSensorConfigurationTable/overCurrentProtectorSensorAccuracy
|
|
overCurrentProtectorSensorConfigurationTable/overCurrentProtectorSensorTolerance
|
|
externalSensorConfigurationTable/externalSensorAccuracy
|
|
externalSensorConfigurationTable/externalSensorTolerance
|
|
wireSensorConfigurationTable/wireSensorAccuracy
|
|
wireSensorConfigurationTable/wireSensorTolerance
|
|
transferSwitchSensorConfigurationTable/transferSwitchSensorAccuracy
|
|
transferSwitchSensorConfigurationTable/transferSwitchSensorTolerance
|
|
5) Added inletSensorReset and outletSensorReset traps
|
|
6) Added inletSensorControl and inletSensorControlTable
|
|
7) Added outletSensorControl and outletSensorControlTable
|
|
8) Added unknownPeripheralDeviceAttached trap
|
|
"
|
|
|
|
|
|
REVISION "201311210000Z" -- November 21, 2013
|
|
|
|
DESCRIPTION "PX2 release 2.5.20:
|
|
- Support for residual current monitors
|
|
- Support for USB cascading with one IP address
|
|
- Support for line-neutral voltage sensors
|
|
|
|
1) SensorTypeEnumeration: Added
|
|
rmsVoltageLN(25)
|
|
residualCurrent(26)
|
|
rcmState(27)
|
|
2) SensorStateEnumeration: Added
|
|
warning(27)
|
|
critical(28)
|
|
selfTest(29)
|
|
3) inletDeviceCapabilities: Added
|
|
residualCurrent(26)
|
|
rcmState(27)
|
|
4) Added rmsVoltageLN(24) to inletPoleCapabilities
|
|
5) Added inletRCMResidualOperatingCurrent to inletConfigurationTable
|
|
6) Added rcmControl under control
|
|
7) Added rcmSelfTestTable under rcmControl
|
|
8) Added DeviceCascadeTypeEnumeration
|
|
9) Added deviceCascadeType, deviceCascadePosition to unitConfigurationTable
|
|
10) Added agentInetPortNumber under trapInformation
|
|
11) Added agentInetPortNumber as a varbind to all traps
|
|
12) Added peripheralDevicePackageTable containing information on peripheral
|
|
device packages
|
|
"
|
|
|
|
|
|
REVISION "201309180000Z" -- September 18, 2013
|
|
|
|
DESCRIPTION "
|
|
1) Added serverConnectivityUnrecoverable trap
|
|
|
|
"
|
|
|
|
|
|
REVISION "201308010000Z" -- August 1, 2013
|
|
|
|
DESCRIPTION "
|
|
1) Add RCBO OCP types
|
|
|
|
"
|
|
|
|
REVISION "201307100000Z" -- July 10, 2013
|
|
|
|
DESCRIPTION "
|
|
1) Added externalSensorTypeDefaultThresholdsTable
|
|
|
|
"
|
|
|
|
|
|
REVISION "201307020000Z" -- July 2, 2013
|
|
|
|
DESCRIPTION "
|
|
1) Added relayBehaviorOnPowerLoss to unitConfigurationTable
|
|
"
|
|
|
|
|
|
REVISION "201305210000Z" -- May 21, 2013
|
|
|
|
DESCRIPTION "
|
|
1) Added inletEnableState to inletConfigurationTable
|
|
2) Added traps: inletEnabled and inletDisabled
|
|
"
|
|
|
|
|
|
REVISION "201304260000Z" -- April 26, 2013
|
|
|
|
DESCRIPTION "
|
|
1) Added traps: webcamInserted and webcamRemoved
|
|
2) Added trapInformation parameters: webcamModel,webcamConnectionPort
|
|
|
|
"
|
|
|
|
|
|
REVISION "201303270000Z" -- March 27, 2013
|
|
|
|
DESCRIPTION "
|
|
1) Changed outletSource to outletPowerSource in outletConfigurationTable
|
|
2) Changed transferSwitchSource1 and transferSwitchSource2 to
|
|
transferSwitchPowerSource1 and transferSwitchPowerSource2 in transferSwitchConfigurationTable
|
|
3) Changed overCurrentProtectorSource to overCurrentProtectorPowerSource in overCurrentProtectorConfigurationTable
|
|
4) Changed wireSource to wirePowerSource in wireConfigurationTable
|
|
|
|
"
|
|
|
|
REVISION "201303251000Z" -- March 25, 2013
|
|
|
|
DESCRIPTION "
|
|
1) Added comments showing the possible states for each sensor type.
|
|
"
|
|
|
|
|
|
REVISION "201303250000Z" -- March 25, 2013
|
|
|
|
DESCRIPTION "
|
|
1) Added outletSource to outletConfigurationTable
|
|
2) Added transferSwitchSource1 and transferSwitchSource2 to transferSwitchConfigurationTable
|
|
3) Added overCurrentProtectorSource to overCurrentProtectorConfigurationTable
|
|
4) Added wireSource to wireConfigurationTable
|
|
|
|
"
|
|
|
|
|
|
REVISION "201303180000Z" -- March 18, 2013
|
|
|
|
DESCRIPTION " 1) Added meteringControllerCount to the unitConfigurationTable
|
|
2) Added meteringController to BoardTypeEnumeration
|
|
"
|
|
|
|
|
|
REVISION "201302250000Z" -- February 25, 2013
|
|
|
|
DESCRIPTION "
|
|
1) Added ProductTypeEnumeration
|
|
2) Added productType to unitConfigurationTable
|
|
"
|
|
|
|
|
|
REVISION "201302040000Z" -- February 04, 2013
|
|
|
|
DESCRIPTION " 1) Added TransferSwitchTransferReasonEnumeration
|
|
2) Added transferSwitchLastTransferReason to transferSwitchControlTable
|
|
3) Added transferSwitchLastTransferReason to transferSwitchSensorStateChange trap
|
|
"
|
|
|
|
|
|
REVISION "201301240000Z" -- January 24, 2013
|
|
|
|
DESCRIPTION "Added required sensor types and units
|
|
"
|
|
|
|
REVISION "201211200000Z" -- November 20, 2012
|
|
|
|
DESCRIPTION "1) Added externalSensorIsActuator and externalSensorPosition to the externalSensorConfigurationTable
|
|
2) Added actuatorControlTable
|
|
"
|
|
|
|
|
|
REVISION "201211150000Z" -- November 15, 2012
|
|
|
|
DESCRIPTION "1) Removed transferSwitchOutputCapabilities from transferSwitchConfigurationTable
|
|
2) Removed the following tables:
|
|
transferSwitchOutputSensorConfigurationTable
|
|
transferSwitchOutputSensorLogTable
|
|
transferSwitchOutputSensorMeasurementsTable
|
|
3) Removed transferSwitchOutputSensorStateChange trap
|
|
4) Added transferSwitchControlTable
|
|
5) Removed the following entries from SensorTypeEnumeration:
|
|
overTemperatureFault
|
|
fans
|
|
internalFault
|
|
inletPhaseDeviationFault
|
|
overloadFault
|
|
6) Added the following entries to SensorTypeEnumeration:
|
|
overloadStatus
|
|
overheatStatus
|
|
scrOpenStatus
|
|
scrShortStatus
|
|
fanStatus
|
|
inletPhaseSyncAngle
|
|
inletPhaseSync
|
|
7) Added the following entries to SensorStateEnumeration:
|
|
inSync,
|
|
outOfSync
|
|
8) Renamed transferSwitchNoTransferIfPhaseDeviationFault to
|
|
transferSwitchAutoReTransferRequiresPhaseSync
|
|
"
|
|
|
|
|
|
REVISION "201210050000Z" -- October 5, 2012
|
|
|
|
DESCRIPTION "1) Modified the DESCRIPTION of the following.
|
|
outletSwitchControlTable
|
|
transferSwitchOutputSensorMeasurementsEntry
|
|
overCurrentProtectorSensorMeasurementsEntry
|
|
outletPoleSensorMeasurementsEntry
|
|
transferSwitchOutputSensorLogEntry
|
|
transferSwitchOutputSensorLogTable
|
|
wireSensorLogEntry
|
|
externalSensorNumber
|
|
controllerConfigurationEntry
|
|
SensorUnitsEnumeration
|
|
measurementsGroup
|
|
logGroup
|
|
"
|
|
|
|
|
|
|
|
REVISION "201210040000Z" -- October 4, 2012
|
|
|
|
DESCRIPTION "1) In the transferSwitchConfigurationTable,
|
|
replaced transferSwitchFrequencyDeviation with
|
|
transferSwitchLowerMarginalFrequency and transferSwitchUpperMarginalFrequency
|
|
"
|
|
|
|
|
|
REVISION "201209280000Z" -- September 28, 2012
|
|
|
|
DESCRIPTION "1) Modified the DESCRIPTION of the following.
|
|
bulkConfigurationCopied, userModified, userSessionTimeout
|
|
"
|
|
|
|
|
|
REVISION "201209210000Z" -- September 21, 2012
|
|
|
|
DESCRIPTION "1) Added the following traps:
|
|
deviceSettingsSaved, deviceSettingsRestored
|
|
"
|
|
|
|
|
|
REVISION "201209200000Z" -- September 20, 2012
|
|
|
|
DESCRIPTION "1) Added the following objects to the transferSwitchConfigurationTable:
|
|
transferSwitchInternalFaultType
|
|
2) Added transferSwitchInternalFaultType to transferSwitchSensorStateChange trap
|
|
3) Added marginal to SensorStateEnumeration
|
|
"
|
|
|
|
|
|
REVISION "201209170000Z" -- September 17, 2012
|
|
|
|
DESCRIPTION "Deprecated the following objects from the unitConfigurationTable
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
pxInetNetmask,
|
|
pxInetGateway
|
|
|
|
"
|
|
|
|
REVISION "201209040000Z" -- September 4, 2012
|
|
|
|
DESCRIPTION "Support for transfer Switch objects and sensors.
|
|
1. Added transferSwitchCount to unitConfigurationTable
|
|
2. Added the following tables:
|
|
transferSwitchConfigurationTable,
|
|
transferSwitchSensorConfigurationTable,
|
|
transferSwitchSensorLogTable,
|
|
transferSwitchSensorMeasurementsTable
|
|
transferSwitchOutputSensorConfigurationTable,
|
|
transferSwitchOutputSensorLogTable,
|
|
transferSwitchOutputSensorMeasurementsTable
|
|
3. Added
|
|
transferSwitchSensorStateChange trap
|
|
transferSwitchOutputSensorStateChange trap
|
|
|
|
"
|
|
|
|
REVISION "201206220000Z" -- June 22, 2012
|
|
|
|
DESCRIPTION "
|
|
1. Added surgeProtectorStatus to SensorTypeEnumeration
|
|
2. Added surgeProtectorStatus to inletDeviceCapabilities
|
|
"
|
|
|
|
|
|
REVISION "201206180000Z" -- June 18, 2012
|
|
|
|
DESCRIPTION "Added a comment before the section listing the traps.
|
|
The comment notes that the pxInetIPAddressType and
|
|
pxInetIPAddress fields are not used for IPv6 traps
|
|
"
|
|
|
|
|
|
|
|
|
|
|
|
REVISION "201206060000Z" -- June 6, 2012
|
|
|
|
DESCRIPTION "Support for wire objects and sensors.
|
|
1. Added wireCount to unitConfigurationTable
|
|
2. Added the following tables:
|
|
wireConfigurationTable,
|
|
wireSensorConfigurationTable,
|
|
wireSensorLogTable,
|
|
wireSensorMeasurementsTable
|
|
3. Added wireSensorStateChange trap
|
|
"
|
|
|
|
|
|
REVISION "201205250000Z" -- May 25, 2012
|
|
|
|
|
|
DESCRIPTION "added userAccepted/DeclinedRestrictedServiceAgreement traps"
|
|
|
|
REVISION "201205150000Z" -- May 15, 2012
|
|
|
|
DESCRIPTION "
|
|
1. Added support for NTP servers.
|
|
Added the following objects under info
|
|
synchronizeWithNTPServer, useDHCPProvidedNTPServer,
|
|
firstNTPServerAddressType, firstNTPServerAddress,
|
|
secondNTPServerAddressType, secondNTPServerAddress
|
|
|
|
"
|
|
|
|
|
|
REVISION "201203260000Z" -- March 26, 2012
|
|
|
|
DESCRIPTION "added lhxSupportChanged trap."
|
|
|
|
|
|
REVISION "201112130000Z" -- December 13, 2011
|
|
|
|
DESCRIPTION "
|
|
1. Added usbSlaveConnected, usbSlaveDisonnected traps
|
|
|
|
"
|
|
|
|
|
|
|
|
|
|
REVISION "201111290000Z" -- November 29, 2011
|
|
|
|
DESCRIPTION "
|
|
1. Added cascadedDeviceConnected to UnitConfigurationEntryStruct
|
|
|
|
"
|
|
|
|
|
|
REVISION "201110250000Z" -- October 25, 2011
|
|
|
|
DESCRIPTION "
|
|
1. Added DeviceIdentificationParameterEnumeration
|
|
2. Added deviceIdentificationChanged Trap
|
|
3. Added sysContact, sysName, sysLocation to all traps
|
|
|
|
"
|
|
|
|
|
|
REVISION "201106160000Z" -- June 16, 2011
|
|
|
|
DESCRIPTION "
|
|
1. Changed DESCRIPTION of outletSequencingDelay
|
|
|
|
"
|
|
|
|
|
|
REVISION "201103220000Z" -- March 22, 2011
|
|
|
|
DESCRIPTION "
|
|
1. Added rfCodeTagConnected, rfCodeTagDisconnected traps
|
|
2. Changed MAX-ACCESS for externalOnOffSensorSubtype to read-write
|
|
"
|
|
|
|
|
|
REVISION "201102210000Z" -- February 21, 2011
|
|
|
|
DESCRIPTION "
|
|
1. Added rpm(19) to SensorUnitsEnumeration
|
|
"
|
|
|
|
|
|
REVISION "201102140000Z" -- February 14, 2011
|
|
|
|
DESCRIPTION "
|
|
1. Changed 5WIRE IEC60309 enumerations from 250V to 208V
|
|
"
|
|
|
|
REVISION "201102080000Z" -- February 8, 2011
|
|
|
|
DESCRIPTION "
|
|
1. Removed OnOffSensorSubtypeEnumeration
|
|
2. Changed SYNTAX of externalOnOffSensorSubtype to SensorTypeEnumeration
|
|
3. Added binary, contact, fanspeed, none to SensorTypeEnumeration
|
|
4. Changed outletPoleCapabilities to be the same as inletPoleCapabilities
|
|
"
|
|
|
|
REVISION "201102030000Z" -- February 3, 2011
|
|
|
|
DESCRIPTION "
|
|
1. Added externalSensorSerialNumber,externalOnOffSensorSubtype, externalSensorChannelNumber
|
|
to the externalSensorStateChange trap."
|
|
|
|
REVISION "201101310000Z" -- January 31, 2011
|
|
|
|
DESCRIPTION "
|
|
1. Modifed the DESCRIPTION of the powerControl trap
|
|
"
|
|
|
|
|
|
REVISION "201012150000Z" -- December 15, 2010
|
|
|
|
DESCRIPTION "
|
|
1. Added dataLoggingEnableForAllSensors to logConfigurationTable
|
|
"
|
|
|
|
|
|
REVISION "201012131131Z" -- December 13, 2010
|
|
|
|
DESCRIPTION "
|
|
1. Added inrushGuardDelay to unitConfigurationTable
|
|
2. Added outletSequenceDelay to outletConfigurationTable
|
|
3. Deprecated outletSequencingDelay
|
|
"
|
|
|
|
|
|
REVISION "201012130000Z" -- December 13, 2010
|
|
|
|
DESCRIPTION "1. Added externalOnOffSensorSubtype to ExternalSensorConfigurationEntryStruct
|
|
2. Added OnOffSensorSubtypeEnumeration
|
|
3. Added alarmed to SensorStateEnumeration
|
|
4. Removed firmwareFileDiscarded trap
|
|
5. Removed securityViolation trap
|
|
"
|
|
|
|
|
|
REVISION "201012070000Z" -- December 7, 2010
|
|
|
|
DESCRIPTION "1. changed DESCRIPTION of measurementPeriod to say that the value is fixed at 1 second.
|
|
"
|
|
|
|
REVISION "201010070000Z" -- October 7, 2010
|
|
|
|
DESCRIPTION "1. added ocpFUSEPAIR(5) to OverCurrentProtectorTypeEnumeration
|
|
2. changed ocpFUSE1POLE(4) to ocpFUSE(4) in OverCurrentProtectorTypeEnumeration
|
|
"
|
|
|
|
REVISION "201010040000Z" -- October 4, 2010
|
|
|
|
DESCRIPTION "1. added ocpFUSE2POLE(5) to OverCurrentProtectorTypeEnumeration
|
|
2. changed ocpFUSE(4) to ocpFUSE1POLE(4) in OverCurrentProtectorTypeEnumeration
|
|
"
|
|
|
|
REVISION "201009010000Z" -- September 1, 2010
|
|
|
|
DESCRIPTION "1. Removed userName from serverNotReachable and serverReachable traps
|
|
"
|
|
|
|
REVISION "201008050000Z" -- August 5, 2010
|
|
|
|
DESCRIPTION "1. Added reliabilityDataTableSequenceNumber
|
|
2. Changed SYNTAX of reliabilityErrorLogIndex to Integer32(1..2147483647)"
|
|
|
|
REVISION "201007230000Z" -- July 23, 2010
|
|
|
|
DESCRIPTION "1. Moved serverCount to unitConfigurationTable "
|
|
|
|
|
|
REVISION "201007220000Z" -- July 22, 2010
|
|
|
|
DESCRIPTION "1. Added support for the Reliability Tables
|
|
2. Added new group reliabilityGroup
|
|
3. Defined nodes reliability,reliabilityData,reliabilityErrorLog
|
|
4. Added reliabilityDataTable & reliabilityErrorLogTable"
|
|
|
|
|
|
|
|
REVISION "201007210000Z" -- July 21, 2010
|
|
|
|
DESCRIPTION "1. Added plug56PA320 to PlugTypeEnumeration
|
|
2. Added plug56P320F to PlugTypeEnumeration"
|
|
|
|
REVISION "201007140000Z" -- July 14, 2010
|
|
|
|
DESCRIPTION "1. Added the following traps:
|
|
pingServerEnabled, pingServerDisabled, serverNotReachable, serverReachable
|
|
2. Added the serverReachabilityTable
|
|
"
|
|
|
|
|
|
REVISION "201007060000Z" -- July 6, 2010
|
|
|
|
DESCRIPTION "1. Added externalSensorChannelNumber to externalSensorConfigurationTable
|
|
"
|
|
|
|
|
|
|
|
REVISION "201007010000Z" -- July 1, 2010
|
|
|
|
DESCRIPTION "1. added outletSwitchingState to outletSwitchControlTable
|
|
2. added outletSwitchingTimeStamp to outletSwitchControlTable"
|
|
|
|
|
|
|
|
REVISION "201006300000Z" -- June 30, 2010
|
|
|
|
DESCRIPTION "1. added switchingOperation to the powerControl trap
|
|
"
|
|
|
|
|
|
REVISION "201006210000Z" -- June 21, 2010
|
|
|
|
DESCRIPTION "1. added support for Load shedding
|
|
2. added loadShedding to the unitConfigurationTable.
|
|
3. added nonCritical to the outletConfigurationTable
|
|
4. added loadSheddingModeEntered & loadSheddingModeExited traps
|
|
5. modified description of inletPlug in inletConfigurationTable"
|
|
|
|
REVISION "201006030000Z" -- June 3, 2010
|
|
|
|
DESCRIPTION "1. added plugOTHER to PlugTypeEnumeration
|
|
2. added receptacleOTHER to ReceptacleTypeEnumeration
|
|
3. added inletPlugDescriptor to inletConfigurationTable
|
|
4. added outletReceptacleDescriptor to outletConfigurationTable
|
|
"
|
|
|
|
REVISION "201005270000Z" -- May 27, 2010
|
|
|
|
DESCRIPTION "1. added INetAddressType and INetAddress to represent IP addresses
|
|
2. unitConfigurationTable: deprecated pxIpAddress
|
|
3. unitConfigurationTable: added pxInetAddressType,pxInetIPAddress,pxInetNetmask,pxInetGateway
|
|
2: added pxInetAddressType,pxInetIPAddress to all traps
|
|
3: defined new trap deviceUpdateFailed"
|
|
|
|
REVISION "201005240000Z" -- May 24, 2010
|
|
|
|
DESCRIPTION "Added typeOfSensor to externalSensorStateChange trap"
|
|
|
|
REVISION "201004190000Z" -- April 19, 2010
|
|
|
|
DESCRIPTION "modified the DESCRIPTION of the deviceUpdateCompleted trap"
|
|
|
|
REVISION "201004150000Z" -- April 15, 2010
|
|
|
|
DESCRIPTION "modified the DESCRIPTION of all SensorStateChangeDelay parameters"
|
|
|
|
|
|
REVISION "201004080000Z" -- April 8, 2010
|
|
|
|
DESCRIPTION "modified the DESCRIPTION of sensor parameters that do not apply to discrete sensors"
|
|
|
|
REVISION "201003290000Z" -- March 29, 2010
|
|
|
|
DESCRIPTION "added trap ldapError"
|
|
|
|
|
|
REVISION "201003250000Z" -- March 25, 2010
|
|
|
|
DESCRIPTION "changed the SYNTAX of the following objects from Integer32 to Unsigned32:
|
|
logInletSensorMaxValue,
|
|
logInletSensorMinValue,
|
|
logInletSensorAvgValue,
|
|
logInletPoleSensorMaxValue,
|
|
logInletPoleSensorMinValue,
|
|
logInletPoleSensorAvgValue,
|
|
logOutletSensorMaxValue,
|
|
logOutletSensorMinValue,
|
|
logOutletSensorAvgValue,
|
|
logOutletPoleSensorMaxValue,
|
|
logOutlePoletSensorMinValue,
|
|
logOutletPoleSensorAvgValue,
|
|
logOverCurrentProtectorSensorMaxValue,
|
|
logOverCurrentProtectorSensorMinValue,
|
|
logOverCurrentProtectorSensorAvgValue,
|
|
measurementsInletSensorValue,
|
|
measurementsInletPoleSensorValue,
|
|
measurementsOutletSensorValue,
|
|
measurementsOutletPoleSensorValue,
|
|
measurementsOverCurrentProtectorSensorValue"
|
|
|
|
REVISION "201003160000Z" -- March 16, 2010
|
|
|
|
DESCRIPTION "added trap smtpMessageTransmissionFailure"
|
|
|
|
REVISION "201003010000Z" -- March 1, 2010
|
|
|
|
DESCRIPTION "changed externalSensorsZCoordinateUnits to an Enumeration"
|
|
|
|
REVISION "201001290000Z" -- January 29, 2010
|
|
|
|
DESCRIPTION "The first version of the MIB."
|
|
|
|
|
|
|
|
|
|
::= { enterprises 13742 }
|
|
|
|
pdu2 OBJECT IDENTIFIER ::= { raritan 6 }
|
|
|
|
traps OBJECT IDENTIFIER ::= { pdu2 0 }
|
|
trapInformation OBJECT IDENTIFIER ::= { traps 0 }
|
|
board OBJECT IDENTIFIER ::= { pdu2 1 }
|
|
environmental OBJECT IDENTIFIER ::= { pdu2 2 }
|
|
configuration OBJECT IDENTIFIER ::= { pdu2 3 }
|
|
control OBJECT IDENTIFIER ::= { pdu2 4 }
|
|
measurements OBJECT IDENTIFIER ::= { pdu2 5 }
|
|
log OBJECT IDENTIFIER ::= { pdu2 6 }
|
|
conformance OBJECT IDENTIFIER ::= { pdu2 9 }
|
|
reliability OBJECT IDENTIFIER ::= { pdu2 10 }
|
|
|
|
unit OBJECT IDENTIFIER ::= { configuration 2 }
|
|
inlets OBJECT IDENTIFIER ::= { configuration 3 }
|
|
overCurrentProtector OBJECT IDENTIFIER ::= { configuration 4 }
|
|
outlets OBJECT IDENTIFIER ::= { configuration 5 }
|
|
externalSensors OBJECT IDENTIFIER ::= { configuration 6 }
|
|
serverReachability OBJECT IDENTIFIER ::= { configuration 7 }
|
|
wires OBJECT IDENTIFIER ::= { configuration 8 }
|
|
transferSwitch OBJECT IDENTIFIER ::= { configuration 9 }
|
|
|
|
|
|
|
|
outletControl OBJECT IDENTIFIER ::= { control 1 }
|
|
externalSensorControl OBJECT IDENTIFIER ::= { control 2 }
|
|
transferSwitchControl OBJECT IDENTIFIER ::= { control 3 }
|
|
actuatorControl OBJECT IDENTIFIER ::= { control 4 }
|
|
rcmControl OBJECT IDENTIFIER ::= { control 5 }
|
|
inletSensorControl OBJECT IDENTIFIER ::= { control 6 }
|
|
outletSensorControl OBJECT IDENTIFIER ::= { control 7 }
|
|
unitSensorControl OBJECT IDENTIFIER ::= { control 8 }
|
|
|
|
|
|
measurementsUnit OBJECT IDENTIFIER ::= { measurements 1 }
|
|
measurementsInlet OBJECT IDENTIFIER ::= { measurements 2 }
|
|
measurementsOverCurrentProtector OBJECT IDENTIFIER ::= { measurements 3 }
|
|
measurementsOutlet OBJECT IDENTIFIER ::= { measurements 4 }
|
|
measurementsExternalSensor OBJECT IDENTIFIER ::= { measurements 5 }
|
|
measurementsWire OBJECT IDENTIFIER ::= { measurements 6 }
|
|
measurementsTransferSwitch OBJECT IDENTIFIER ::= { measurements 7 }
|
|
|
|
logUnit OBJECT IDENTIFIER ::= { log 1 }
|
|
logInlet OBJECT IDENTIFIER ::= { log 2 }
|
|
logOverCurrentProtector OBJECT IDENTIFIER ::= { log 3 }
|
|
logOutlet OBJECT IDENTIFIER ::= { log 4 }
|
|
logExternalSensor OBJECT IDENTIFIER ::= { log 5 }
|
|
logWire OBJECT IDENTIFIER ::= { log 6 }
|
|
logTransferSwitch OBJECT IDENTIFIER ::= { log 7 }
|
|
|
|
reliabilityData OBJECT IDENTIFIER ::= { reliability 1 }
|
|
reliabilityErrorLog OBJECT IDENTIFIER ::= { reliability 2 }
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
compliances OBJECT IDENTIFIER ::= { conformance 1 }
|
|
groups OBJECT IDENTIFIER ::= { conformance 2 }
|
|
|
|
-- Conformance Information
|
|
-- compliance statements
|
|
|
|
complianceRev2 MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The requirements for conformance to the PDU2-MIB."
|
|
MODULE -- this module
|
|
|
|
GROUP configGroup
|
|
DESCRIPTION
|
|
"The configuration group."
|
|
|
|
GROUP logGroup
|
|
DESCRIPTION
|
|
"The log group."
|
|
|
|
GROUP measurementsGroup
|
|
DESCRIPTION
|
|
"The measurements group."
|
|
|
|
GROUP controlGroup
|
|
DESCRIPTION
|
|
"The control group."
|
|
|
|
GROUP trapInformationGroup
|
|
DESCRIPTION
|
|
"The information group."
|
|
|
|
GROUP trapsGroup
|
|
DESCRIPTION
|
|
"The information group."
|
|
|
|
GROUP reliabilityGroup
|
|
DESCRIPTION
|
|
"The reliability group."
|
|
|
|
::= { compliances 2 }
|
|
|
|
complianceRev1 MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The requirements for conformance to the PDU2-MIB."
|
|
MODULE -- this module
|
|
|
|
GROUP ipAddressGroup
|
|
DESCRIPTION
|
|
"The ipAddress group."
|
|
|
|
GROUP oldConfigGroup
|
|
DESCRIPTION
|
|
"old (deprecated) configuration data"
|
|
|
|
GROUP oldLogGroup
|
|
DESCRIPTION
|
|
"old (deprecated) logging data"
|
|
|
|
GROUP oldMeasurementsGroup
|
|
DESCRIPTION
|
|
"old (deprecated) measurement data"
|
|
|
|
GROUP oldTrapsGroup
|
|
DESCRIPTION
|
|
"old (deprecated) traps"
|
|
|
|
::= { compliances 1 }
|
|
|
|
|
|
|
|
|
|
-- units of conformance
|
|
|
|
configGroup OBJECT-GROUP
|
|
OBJECTS { pduCount,
|
|
pduManufacturer,
|
|
pduModel,
|
|
pduSerialNumber,
|
|
pduRatedVoltage,
|
|
pduRatedCurrent,
|
|
pduRatedFrequency,
|
|
pduRatedVA,
|
|
pduImage,
|
|
inletCount,
|
|
transferSwitchCount,
|
|
productType,
|
|
overCurrentProtectorCount,
|
|
outletCount,
|
|
inletControllerCount,
|
|
outletControllerCount,
|
|
meteringControllerCount,
|
|
externalSensorCount,
|
|
pxMACAddress,
|
|
utcOffset,
|
|
pduName,
|
|
boardVersion,
|
|
boardFirmwareVersion,
|
|
boardFirmwareTimeStamp,
|
|
unitSensorLogAvailable,
|
|
unitSensorUnits,
|
|
unitSensorDecimalDigits,
|
|
unitSensorResolution,
|
|
unitSensorMaximum,
|
|
unitSensorMinimum,
|
|
unitSensorHysteresis,
|
|
unitSensorStateChangeDelay,
|
|
unitSensorLowerCriticalThreshold,
|
|
unitSensorLowerWarningThreshold,
|
|
unitSensorUpperCriticalThreshold,
|
|
unitSensorUpperWarningThreshold,
|
|
unitSensorEnabledThresholds,
|
|
unitSensorSignedMaximum,
|
|
unitSensorSignedMinimum,
|
|
unitSensorSignedLowerCriticalThreshold,
|
|
unitSensorSignedLowerWarningThreshold,
|
|
unitSensorSignedUpperCriticalThreshold,
|
|
unitSensorSignedUpperWarningThreshold,
|
|
inletLabel,
|
|
inletName,
|
|
inletPlug,
|
|
inletPoleCount,
|
|
inletRatedVoltage,
|
|
inletRatedCurrent,
|
|
inletRatedFrequency,
|
|
inletRatedVA,
|
|
inletDeviceCapabilities,
|
|
inletPoleCapabilities,
|
|
inletPlugDescriptor,
|
|
inletEnableState,
|
|
inletSensorLogAvailable,
|
|
inletSensorUnits,
|
|
inletSensorDecimalDigits,
|
|
inletSensorResolution,
|
|
inletSensorMaximum,
|
|
inletSensorMinimum,
|
|
inletSensorHysteresis,
|
|
inletSensorStateChangeDelay,
|
|
inletSensorLowerCriticalThreshold,
|
|
inletSensorLowerWarningThreshold,
|
|
inletSensorUpperCriticalThreshold,
|
|
inletSensorUpperWarningThreshold,
|
|
inletSensorEnabledThresholds,
|
|
inletSensorSignedMaximum,
|
|
inletSensorSignedMinimum,
|
|
inletSensorSignedLowerCriticalThreshold,
|
|
inletSensorSignedLowerWarningThreshold,
|
|
inletSensorSignedUpperCriticalThreshold,
|
|
inletSensorSignedUpperWarningThreshold,
|
|
inletPoleSensorLogAvailable,
|
|
inletPoleSensorUnits,
|
|
inletPoleSensorDecimalDigits,
|
|
inletPoleSensorResolution,
|
|
inletPoleSensorMaximum,
|
|
inletPoleSensorMinimum,
|
|
inletPoleSensorHysteresis,
|
|
inletPoleSensorStateChangeDelay,
|
|
inletPoleSensorLowerCriticalThreshold,
|
|
inletPoleSensorLowerWarningThreshold,
|
|
inletPoleSensorUpperCriticalThreshold,
|
|
inletPoleSensorUpperWarningThreshold,
|
|
inletPoleSensorEnabledThresholds,
|
|
inletPoleSensorSignedMaximum,
|
|
inletPoleSensorSignedMinimum,
|
|
inletPoleSensorSignedLowerCriticalThreshold,
|
|
inletPoleSensorSignedLowerWarningThreshold,
|
|
inletPoleSensorSignedUpperCriticalThreshold,
|
|
inletPoleSensorSignedUpperWarningThreshold,
|
|
inletRCMResidualOperatingCurrent,
|
|
overCurrentProtectorLabel,
|
|
overCurrentProtectorName,
|
|
overCurrentProtectorType,
|
|
overCurrentProtectorRatedCurrent,
|
|
overCurrentProtectorCapabilities,
|
|
overCurrentProtectorSensorLogAvailable,
|
|
overCurrentProtectorSensorUnits,
|
|
overCurrentProtectorSensorDecimalDigits,
|
|
overCurrentProtectorSensorResolution,
|
|
overCurrentProtectorSensorMaximum,
|
|
overCurrentProtectorSensorMinimum,
|
|
overCurrentProtectorSensorHysteresis,
|
|
overCurrentProtectorSensorStateChangeDelay,
|
|
overCurrentProtectorSensorLowerCriticalThreshold,
|
|
overCurrentProtectorSensorLowerWarningThreshold,
|
|
overCurrentProtectorSensorUpperCriticalThreshold,
|
|
overCurrentProtectorSensorUpperWarningThreshold,
|
|
overCurrentProtectorSensorEnabledThresholds,
|
|
overCurrentProtectorSensorSignedMaximum,
|
|
overCurrentProtectorSensorSignedMinimum,
|
|
overCurrentProtectorSensorSignedLowerCriticalThreshold,
|
|
overCurrentProtectorSensorSignedLowerWarningThreshold,
|
|
overCurrentProtectorSensorSignedUpperCriticalThreshold,
|
|
overCurrentProtectorSensorSignedUpperWarningThreshold,
|
|
overCurrentProtectorPowerSource,
|
|
outletLabel,
|
|
outletName,
|
|
outletReceptacle,
|
|
outletPoleCount,
|
|
outletRatedVoltage,
|
|
outletRatedCurrent,
|
|
outletRatedVA,
|
|
outletDeviceCapabilities,
|
|
outletPoleCapabilities,
|
|
outletPowerCyclingPowerOffPeriod,
|
|
outletStateOnStartup,
|
|
outletUseGlobalPowerCyclingPowerOffPeriod,
|
|
outletSwitchable,
|
|
outletReceptacleDescriptor,
|
|
outletNonCritical,
|
|
outletSequenceDelay,
|
|
outletSensorLogAvailable,
|
|
outletSensorUnits,
|
|
outletSensorDecimalDigits,
|
|
outletSensorResolution,
|
|
outletSensorMaximum,
|
|
outletSensorMinimum,
|
|
outletSensorHysteresis,
|
|
outletSensorStateChangeDelay,
|
|
outletSensorLowerCriticalThreshold,
|
|
outletSensorLowerWarningThreshold,
|
|
outletSensorUpperCriticalThreshold,
|
|
outletSensorUpperWarningThreshold,
|
|
outletSensorEnabledThresholds,
|
|
outletSensorSignedMaximum,
|
|
outletSensorSignedMinimum,
|
|
outletSensorSignedLowerCriticalThreshold,
|
|
outletSensorSignedLowerWarningThreshold,
|
|
outletSensorSignedUpperCriticalThreshold,
|
|
outletSensorSignedUpperWarningThreshold,
|
|
outletPoleSensorLogAvailable,
|
|
outletPoleSensorUnits,
|
|
outletPoleSensorDecimalDigits,
|
|
outletPoleSensorResolution,
|
|
outletPoleSensorMaximum,
|
|
outletPoleSensorMinimum,
|
|
outletPoleSensorHysteresis,
|
|
outletPoleSensorStateChangeDelay,
|
|
outletPoleSensorLowerCriticalThreshold,
|
|
outletPoleSensorLowerWarningThreshold,
|
|
outletPoleSensorUpperCriticalThreshold,
|
|
outletPoleSensorUpperWarningThreshold,
|
|
outletPoleSensorEnabledThresholds,
|
|
outletPoleSensorSignedMaximum,
|
|
outletPoleSensorSignedMinimum,
|
|
outletPoleSensorSignedLowerCriticalThreshold,
|
|
outletPoleSensorSignedLowerWarningThreshold,
|
|
outletPoleSensorSignedUpperCriticalThreshold,
|
|
outletPoleSensorSignedUpperWarningThreshold,
|
|
outletPowerSource,
|
|
externalSensorType,
|
|
externalSensorSerialNumber,
|
|
externalSensorName,
|
|
externalSensorDescription,
|
|
externalSensorXCoordinate,
|
|
externalSensorYCoordinate,
|
|
externalSensorZCoordinate,
|
|
externalSensorChannelNumber,
|
|
externalOnOffSensorSubtype,
|
|
externalSensorLogAvailable,
|
|
externalSensorUnits,
|
|
externalSensorDecimalDigits,
|
|
externalSensorResolution,
|
|
externalSensorMaximum,
|
|
externalSensorMinimum,
|
|
externalSensorHysteresis,
|
|
externalSensorStateChangeDelay,
|
|
externalSensorLowerCriticalThreshold,
|
|
externalSensorLowerWarningThreshold,
|
|
externalSensorUpperCriticalThreshold,
|
|
externalSensorUpperWarningThreshold,
|
|
externalSensorEnabledThresholds,
|
|
externalSensorsZCoordinateUnits,
|
|
externalSensorIsActuator,
|
|
externalSensorPosition,
|
|
externalSensorUseDefaultThresholds,
|
|
externalSensorTypeDefaultHysteresis,
|
|
externalSensorTypeDefaultStateChangeDelay,
|
|
externalSensorTypeDefaultLowerCriticalThreshold,
|
|
externalSensorTypeDefaultLowerWarningThreshold,
|
|
externalSensorTypeDefaultUpperCriticalThreshold,
|
|
externalSensorTypeDefaultUpperWarningThreshold,
|
|
externalSensorTypeDefaultEnabledThresholds,
|
|
measurementPeriod,
|
|
measurementsPerLogEntry,
|
|
logSize,
|
|
unitDeviceCapabilities,
|
|
globalOutletPowerCyclingPowerOffPeriod,
|
|
globalOutletStateOnStartup,
|
|
relayBehaviorOnPowerLoss,
|
|
pduPowerCyclingPowerOffPeriod,
|
|
pduDaisychainMemberType,
|
|
managedExternalSensorCount,
|
|
outletPowerupSequence,
|
|
loadShedding,
|
|
serverCount,
|
|
serverIPAddress,
|
|
serverPingEnabled,
|
|
inrushGuardDelay,
|
|
cascadedDeviceConnected,
|
|
synchronizeWithNTPServer,
|
|
useDHCPProvidedNTPServer,
|
|
firstNTPServerAddressType,
|
|
firstNTPServerAddress,
|
|
secondNTPServerAddressType,
|
|
secondNTPServerAddress,
|
|
transferSwitchLabel,
|
|
transferSwitchName,
|
|
transferSwitchPreferredInlet,
|
|
transferSwitchAutoReTransferEnabled,
|
|
transferSwitchAutoReTransferWaitTime,
|
|
transferSwitchAutoReTransferRequiresPhaseSync,
|
|
transferSwitchFrontPanelManualTransferButtonEnabled,
|
|
transferSwitchCapabilities,
|
|
transferSwitchSensorLogAvailable,
|
|
transferSwitchSensorUnits,
|
|
transferSwitchSensorDecimalDigits,
|
|
transferSwitchSensorResolution,
|
|
transferSwitchSensorMaximum,
|
|
transferSwitchSensorMinimum,
|
|
transferSwitchSensorHysteresis,
|
|
transferSwitchSensorStateChangeDelay,
|
|
transferSwitchSensorLowerCriticalThreshold,
|
|
transferSwitchSensorLowerWarningThreshold,
|
|
transferSwitchSensorUpperCriticalThreshold,
|
|
transferSwitchSensorUpperWarningThreshold,
|
|
transferSwitchSensorEnabledThresholds,
|
|
transferSwitchSensorSignedMaximum,
|
|
transferSwitchSensorSignedMinimum,
|
|
transferSwitchSensorSignedLowerCriticalThreshold,
|
|
transferSwitchSensorSignedLowerWarningThreshold,
|
|
transferSwitchSensorSignedUpperCriticalThreshold,
|
|
transferSwitchSensorSignedUpperWarningThreshold,
|
|
transferSwitchPowerSource1,
|
|
transferSwitchPowerSource2,
|
|
peripheralDevicePackageSerialNumber,
|
|
peripheralDevicePackageModel,
|
|
peripheralDevicePackageFirmwareVersion,
|
|
peripheralDevicePackageMinFirmwareVersion,
|
|
peripheralDevicePackageFirmwareTimeStamp,
|
|
peripheralDevicePackagePosition,
|
|
peripheralDevicePackageState,
|
|
deviceCascadeType,
|
|
deviceCascadePosition,
|
|
peripheralDevicesAutoManagement,
|
|
externalSensorAlarmedToNormalDelay,
|
|
frontPanelOutletSwitching,
|
|
frontPanelRCMSelfTest,
|
|
frontPanelActuatorControl
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects representing configuration data."
|
|
::= { groups 1 }
|
|
|
|
ipAddressGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
pxIPAddress,
|
|
netmask,
|
|
gateway,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
pxInetNetmask,
|
|
pxInetGateway
|
|
}
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"A collection of objects representing configuration data."
|
|
::= { groups 12 }
|
|
|
|
|
|
oldConfigGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
outletSequencingDelay,
|
|
unitSensorAccuracy,
|
|
unitSensorTolerance,
|
|
inletSensorAccuracy,
|
|
inletSensorTolerance,
|
|
inletPoleSensorAccuracy,
|
|
inletPoleSensorTolerance,
|
|
outletSensorAccuracy,
|
|
outletSensorTolerance,
|
|
outletPoleSensorAccuracy,
|
|
outletPoleSensorTolerance,
|
|
overCurrentProtectorSensorAccuracy,
|
|
overCurrentProtectorSensorTolerance,
|
|
externalSensorAccuracy,
|
|
externalSensorTolerance,
|
|
wireSensorAccuracy,
|
|
wireSensorTolerance,
|
|
transferSwitchSensorAccuracy,
|
|
transferSwitchSensorTolerance,
|
|
wireCount,
|
|
wireLabel,
|
|
wireCapabilities,
|
|
wireSensorLogAvailable,
|
|
wireSensorUnits,
|
|
wireSensorDecimalDigits,
|
|
wireSensorResolution,
|
|
wireSensorMaximum,
|
|
wireSensorMinimum,
|
|
wireSensorHysteresis,
|
|
wireSensorStateChangeDelay,
|
|
wireSensorLowerCriticalThreshold,
|
|
wireSensorLowerWarningThreshold,
|
|
wireSensorUpperCriticalThreshold,
|
|
wireSensorUpperWarningThreshold,
|
|
wireSensorEnabledThresholds,
|
|
wirePowerSource
|
|
}
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"A collection of objects representing old (deprecated) configuration data."
|
|
::= { groups 13 }
|
|
|
|
|
|
logGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
dataLogging,
|
|
oldestLogID,
|
|
newestLogID,
|
|
logTimeStamp,
|
|
dataLoggingEnableForAllSensors,
|
|
logUnitSensorDataAvailable,
|
|
logUnitSensorState,
|
|
logUnitSensorAvgValue,
|
|
logUnitSensorMaxValue,
|
|
logUnitSensorMinValue,
|
|
logUnitSensorSignedAvgValue,
|
|
logUnitSensorSignedMaxValue,
|
|
logUnitSensorSignedMinValue,
|
|
logInletSensorDataAvailable,
|
|
logInletSensorState,
|
|
logInletSensorAvgValue,
|
|
logInletSensorMaxValue,
|
|
logInletSensorMinValue,
|
|
logInletSensorSignedAvgValue,
|
|
logInletSensorSignedMaxValue,
|
|
logInletSensorSignedMinValue,
|
|
logInletPoleSensorDataAvailable,
|
|
logInletPoleSensorState,
|
|
logInletPoleSensorAvgValue,
|
|
logInletPoleSensorMaxValue,
|
|
logInletPoleSensorMinValue,
|
|
logInletPoleSensorSignedAvgValue,
|
|
logInletPoleSensorSignedMaxValue,
|
|
logInletPoleSensorSignedMinValue,
|
|
logOutletSensorDataAvailable,
|
|
logOutletSensorState,
|
|
logOutletSensorAvgValue,
|
|
logOutletSensorMaxValue,
|
|
logOutletSensorMinValue,
|
|
logOutletSensorSignedAvgValue,
|
|
logOutletSensorSignedMaxValue,
|
|
logOutletSensorSignedMinValue,
|
|
logOutletPoleSensorDataAvailable,
|
|
logOutletPoleSensorState,
|
|
logOutletPoleSensorAvgValue,
|
|
logOutletPoleSensorMaxValue,
|
|
logOutletPoleSensorMinValue,
|
|
logOutletPoleSensorSignedAvgValue,
|
|
logOutletPoleSensorSignedMaxValue,
|
|
logOutletPoleSensorSignedMinValue,
|
|
logOverCurrentProtectorSensorDataAvailable,
|
|
logOverCurrentProtectorSensorState,
|
|
logOverCurrentProtectorSensorAvgValue,
|
|
logOverCurrentProtectorSensorMaxValue,
|
|
logOverCurrentProtectorSensorMinValue,
|
|
logOverCurrentProtectorSensorSignedAvgValue,
|
|
logOverCurrentProtectorSensorSignedMaxValue,
|
|
logOverCurrentProtectorSensorSignedMinValue,
|
|
logExternalSensorDataAvailable,
|
|
logExternalSensorState,
|
|
logExternalSensorAvgValue,
|
|
logExternalSensorMaxValue,
|
|
logExternalSensorMinValue,
|
|
logTransferSwitchSensorDataAvailable,
|
|
logTransferSwitchSensorState,
|
|
logTransferSwitchSensorAvgValue,
|
|
logTransferSwitchSensorMaxValue,
|
|
logTransferSwitchSensorMinValue,
|
|
logTransferSwitchSensorSignedAvgValue,
|
|
logTransferSwitchSensorSignedMaxValue,
|
|
logTransferSwitchSensorSignedMinValue
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing logging (history of readings) capabilities
|
|
about the PDU."
|
|
::= { groups 2 }
|
|
|
|
|
|
oldLogGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
logWireSensorDataAvailable,
|
|
logWireSensorState,
|
|
logWireSensorAvgValue,
|
|
logWireSensorMaxValue,
|
|
logWireSensorMinValue
|
|
}
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"A collection of objects representing old (deprecated) logging data."
|
|
::= { groups 14 }
|
|
|
|
measurementsGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
measurementsUnitSensorIsAvailable,
|
|
measurementsUnitSensorState,
|
|
measurementsUnitSensorValue,
|
|
measurementsUnitSensorTimeStamp,
|
|
measurementsUnitSensorSignedValue,
|
|
measurementsInletSensorIsAvailable,
|
|
measurementsInletSensorState,
|
|
measurementsInletSensorValue,
|
|
measurementsInletSensorTimeStamp,
|
|
measurementsInletSensorSignedValue,
|
|
measurementsInletPoleSensorIsAvailable,
|
|
measurementsInletPoleSensorState,
|
|
measurementsInletPoleSensorValue,
|
|
measurementsInletPoleSensorTimeStamp,
|
|
measurementsInletPoleSensorSignedValue,
|
|
measurementsOutletSensorIsAvailable,
|
|
measurementsOutletSensorState,
|
|
measurementsOutletSensorValue,
|
|
measurementsOutletSensorTimeStamp,
|
|
measurementsOutletSensorSignedValue,
|
|
measurementsOutletPoleSensorIsAvailable,
|
|
measurementsOutletPoleSensorState,
|
|
measurementsOutletPoleSensorValue,
|
|
measurementsOutletPoleSensorTimeStamp,
|
|
measurementsOutletPoleSensorSignedValue,
|
|
measurementsOverCurrentProtectorSensorIsAvailable,
|
|
measurementsOverCurrentProtectorSensorState,
|
|
measurementsOverCurrentProtectorSensorValue,
|
|
measurementsOverCurrentProtectorSensorTimeStamp,
|
|
measurementsOverCurrentProtectorSensorSignedValue,
|
|
measurementsExternalSensorIsAvailable,
|
|
measurementsExternalSensorState,
|
|
measurementsExternalSensorValue,
|
|
measurementsExternalSensorTimeStamp,
|
|
measurementsTransferSwitchSensorIsAvailable,
|
|
measurementsTransferSwitchSensorState,
|
|
measurementsTransferSwitchSensorValue,
|
|
measurementsTransferSwitchSensorTimeStamp,
|
|
measurementsTransferSwitchSensorSignedValue
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing measurements (most recent data) capabilities.
|
|
about the PDU."
|
|
::= { groups 3 }
|
|
|
|
|
|
oldMeasurementsGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
measurementsWireSensorIsAvailable,
|
|
measurementsWireSensorState,
|
|
measurementsWireSensorValue,
|
|
measurementsWireSensorTimeStamp
|
|
}
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"A collection of objects representing old (deprecated) measurement data."
|
|
::= { groups 15 }
|
|
|
|
controlGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
switchingOperation,
|
|
outletSwitchingState,
|
|
outletSwitchingTimeStamp,
|
|
transferSwitchActiveInlet,
|
|
transferSwitchTransferToInlet,
|
|
transferSwitchAlarmOverride,
|
|
transferSwitchLastTransferReason,
|
|
actuatorState,
|
|
rcmState,
|
|
inletSensorResetValue,
|
|
outletSensorResetValue,
|
|
unitSensorResetValue
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing the ability to control various components
|
|
of a PDU."
|
|
::= { groups 4 }
|
|
|
|
|
|
trapInformationGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
userName,
|
|
targetUser,
|
|
imageVersion,
|
|
roleName,
|
|
oldSensorState,
|
|
pduNumber,
|
|
inletPoleNumber,
|
|
outletPoleNumber,
|
|
externalSensorNumber,
|
|
typeOfSensor,
|
|
smtpMessageRecipients,
|
|
smtpServer,
|
|
errorDescription,
|
|
deviceChangedParameter,
|
|
changedParameterNewValue,
|
|
lhxSupportEnabled,
|
|
webcamModel,
|
|
webcamConnectionPort,
|
|
agentInetPortNumber,
|
|
peripheralDeviceRomcode,
|
|
peripheralDeviceFirmwareUpdateState
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing information in the traps."
|
|
::= { groups 5 }
|
|
|
|
|
|
trapsGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS { systemStarted,
|
|
systemReset,
|
|
userLogin,
|
|
userLogout,
|
|
userAuthenticationFailure,
|
|
userSessionTimeout,
|
|
userAdded,
|
|
userModified,
|
|
userDeleted,
|
|
roleAdded,
|
|
roleModified,
|
|
roleDeleted,
|
|
deviceUpdateStarted,
|
|
deviceUpdateCompleted,
|
|
userBlocked,
|
|
powerControl,
|
|
userPasswordChanged,
|
|
passwordSettingsChanged,
|
|
firmwareValidationFailed,
|
|
logFileCleared,
|
|
bulkConfigurationSaved,
|
|
bulkConfigurationCopied,
|
|
inletSensorStateChange,
|
|
inletPoleSensorStateChange,
|
|
outletSensorStateChange,
|
|
outletPoleSensorStateChange,
|
|
overCurrentProtectorSensorStateChange,
|
|
externalSensorStateChange,
|
|
smtpMessageTransmissionFailure,
|
|
ldapError,
|
|
deviceUpdateFailed,
|
|
loadSheddingModeEntered,
|
|
loadSheddingModeExited,
|
|
pingServerEnabled,
|
|
pingServerDisabled,
|
|
serverNotReachable,
|
|
serverReachable,
|
|
rfCodeTagConnected,
|
|
rfCodeTagDisconnected,
|
|
deviceIdentificationChanged,
|
|
usbSlaveConnected,
|
|
usbSlaveDisconnected,
|
|
lhxSupportChanged,
|
|
userAcceptedRestrictedServiceAgreement,
|
|
userDeclinedRestrictedServiceAgreement,
|
|
transferSwitchSensorStateChange,
|
|
deviceSettingsSaved,
|
|
deviceSettingsRestored,
|
|
webcamInserted,
|
|
webcamRemoved,
|
|
inletEnabled,
|
|
inletDisabled,
|
|
serverConnectivityUnrecoverable,
|
|
radiusError,
|
|
serverReachabilityError,
|
|
inletSensorReset,
|
|
outletSensorReset,
|
|
unitSensorReset,
|
|
unknownPeripheralDeviceAttached,
|
|
peripheralDeviceFirmwareUpdate,
|
|
unitSensorStateChange
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of traps."
|
|
::= { groups 9 }
|
|
|
|
oldTrapsGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS { wireSensorStateChange,
|
|
pduSensorStateChange
|
|
}
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"A collection of objects representing old (deprecated) traps."
|
|
::= { groups 16 }
|
|
|
|
reliabilityGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
reliabilityId,
|
|
reliabilityDataValue,
|
|
reliabilityDataMaxPossible,
|
|
reliabilityDataWorstValue,
|
|
reliabilityDataThreshold,
|
|
reliabilityDataRawUpperBytes,
|
|
reliabilityDataRawLowerBytes,
|
|
reliabilityDataFlags,
|
|
reliabilityErrorLogId,
|
|
reliabilityErrorLogValue,
|
|
reliabilityErrorLogThreshold,
|
|
reliabilityErrorLogRawUpperBytes,
|
|
reliabilityErrorLogRawLowerBytes,
|
|
reliabilityErrorLogPOH,
|
|
reliabilityErrorLogTime,
|
|
reliabilityDataTableSequenceNumber
|
|
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects providing reliability data."
|
|
::= { groups 10 }
|
|
|
|
-- Textual Conventions
|
|
|
|
|
|
|
|
SensorTypeEnumeration ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The types a sensor can be."
|
|
SYNTAX INTEGER {
|
|
rmsCurrent(1),
|
|
peakCurrent(2),
|
|
unbalancedCurrent(3),
|
|
rmsVoltage(4),
|
|
activePower(5),
|
|
apparentPower(6),
|
|
powerFactor(7),
|
|
activeEnergy(8),
|
|
apparentEnergy(9),
|
|
temperature(10),
|
|
humidity(11),
|
|
airFlow(12),
|
|
airPressure(13),
|
|
onOff(14),
|
|
trip(15),
|
|
vibration(16),
|
|
waterDetection(17),
|
|
smokeDetection(18),
|
|
binary(19),
|
|
contact(20),
|
|
fanSpeed(21),
|
|
surgeProtectorStatus(22),
|
|
frequency(23),
|
|
phaseAngle(24),
|
|
rmsVoltageLN(25),
|
|
residualCurrent(26),
|
|
rcmState(27),
|
|
other(30),
|
|
none(31),
|
|
powerQuality(32),
|
|
overloadStatus(33),
|
|
overheatStatus(34),
|
|
fanStatus(37),
|
|
inletPhaseSyncAngle(38),
|
|
inletPhaseSync(39),
|
|
operatingState(40),
|
|
activeInlet(41),
|
|
illuminance(42),
|
|
doorContact(43),
|
|
tamperDetection(44),
|
|
motionDetection(45),
|
|
i1smpsStatus(46),
|
|
i2smpsStatus(47),
|
|
switchStatus(48)
|
|
}
|
|
|
|
|
|
|
|
SensorStateEnumeration ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The states a sensor can be in."
|
|
SYNTAX INTEGER { unavailable(-1),
|
|
open(0),
|
|
closed(1),
|
|
belowLowerCritical(2),
|
|
belowLowerWarning(3),
|
|
normal(4),
|
|
aboveUpperWarning(5),
|
|
aboveUpperCritical(6),
|
|
on(7),
|
|
off(8),
|
|
detected(9),
|
|
notDetected(10),
|
|
alarmed(11),
|
|
ok(12),
|
|
fail(14),
|
|
yes(15),
|
|
no(16),
|
|
standby(17),
|
|
one(18),
|
|
two(19),
|
|
inSync(20),
|
|
outOfSync(21),
|
|
i1OpenFault(22),
|
|
i1ShortFault(23),
|
|
i2OpenFault(24),
|
|
i2ShortFault(25),
|
|
fault(26),
|
|
warning(27),
|
|
critical(28),
|
|
selfTest(29)
|
|
}
|
|
|
|
-- Possible Sensor States for each Sensor Type
|
|
-- This comment must be updated whenever a new sensor type is added.
|
|
-- Sensor Type Sensor States
|
|
-- rmsCurrent unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical
|
|
-- peakCurrent unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical
|
|
-- unbalancedCurrent unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical
|
|
-- rmsVoltage unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical
|
|
-- activePower unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical
|
|
-- apparentPower unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical
|
|
-- powerFactor unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical
|
|
-- activeEnergy unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical
|
|
-- apparentEnergy unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical
|
|
-- temperature unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical
|
|
-- humidity unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical
|
|
-- airFlow unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical
|
|
-- airPressure unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical
|
|
-- onOff unavailable,on,off
|
|
-- trip unavailable,open,closed
|
|
-- vibration unavailable,normal,alarmed
|
|
-- waterDetection unavailable,normal,alarmed
|
|
-- smokeDetection unavailable,normal,alarmed
|
|
-- binary unavailable,normal,alarmed
|
|
-- contact unavailable,normal,alarmed
|
|
-- fanSpeed unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical
|
|
-- surgeProtectorStatus unavailable,ok,fault
|
|
-- frequency unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical
|
|
-- phaseAngle unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical
|
|
-- powerQuality unavailable,normal,warning,critical
|
|
-- overloadStatus unavailable,ok,fault
|
|
-- overheatStatus unavailable,ok,fault
|
|
-- fanStatus unavailable,ok,fault
|
|
-- residualCurrent unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical
|
|
-- rcmState unavailable,normal,alarmed,selfTest,fail
|
|
-- inletPhaseSyncAngle unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical
|
|
-- inletPhaseSync unavailable,inSync,outOfSync
|
|
-- operatingState unavailable,normal,standby,off
|
|
-- activeInlet unavailable,one,two,none
|
|
-- illuminance unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical
|
|
-- doorContact unavailable,open,closed
|
|
-- tamperDetection unavailable,normal,alarmed
|
|
-- motionDetection unavailable,??
|
|
-- i1smpsStatus unavailable,ok,fault
|
|
-- i2smpsStatus unavailable,ok,fault
|
|
-- switchStatus unavailable,ok,i1OpenFault,i1ShortFault,i2OpenFault,i2ShortFault
|
|
|
|
|
|
|
|
|
|
PlugTypeEnumeration ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The types of inlet plug."
|
|
SYNTAX INTEGER { plugOTHER(-1),
|
|
plugNONE(0),
|
|
plug56P320(1),
|
|
plug56P520(2),
|
|
plug56P532(3),
|
|
plugCS8365C(4),
|
|
plugIEC320C14(5),
|
|
plugIEC320C20(6),
|
|
plugIEC603093WIRE250V16A(7),
|
|
plugIEC603093WIRE250V20A(8),
|
|
plugIEC603093WIRE250V30A(9),
|
|
plugIEC603093WIRE250V32A(10),
|
|
plugIEC603093WIRE250V60A(11),
|
|
plugIEC603093WIRE250V63A(12),
|
|
plugIEC603093WIRE250V100A(13),
|
|
plugIEC603093WIRE250V125A(14),
|
|
plugIEC603094WIRE250V20A(15),
|
|
plugIEC603094WIRE250V30A(16),
|
|
plugIEC603094WIRE250V60A(17),
|
|
plugIEC603094WIRE250V100A(18),
|
|
plugIEC603095WIRE208V20A(23),
|
|
plugIEC603095WIRE208V30A(24),
|
|
plugIEC603095WIRE208V60A(25),
|
|
plugIEC603095WIRE208V100A(26),
|
|
plugIEC603095WIRE415V16A(27),
|
|
plugIEC603095WIRE415V32A(28),
|
|
plugIEC603095WIRE415V63A(29),
|
|
plugIEC603095WIRE415V125A(30),
|
|
plugIEC603095WIRE480V20A(31),
|
|
plugIEC603095WIRE480V30A(32),
|
|
plugIEC603095WIRE480V60A(33),
|
|
plugIEC603095WIRE480V100A(34),
|
|
plugNEMA515P(35),
|
|
plugNEMAL515P(36),
|
|
plugNEMA520P(37),
|
|
plugNEMAL520P(38),
|
|
plugNEMAL530P(39),
|
|
plugNEMAL615P(40),
|
|
plugNEMAL620P(41),
|
|
plugNEMAL630P(42),
|
|
plugNEMAL1520P(43),
|
|
plugNEMAL1530P(44),
|
|
plugNEMAL2120P(45),
|
|
plugNEMAL2130P(46),
|
|
plugNEMAL2230P(47),
|
|
plug56P320F(48),
|
|
plug56PA320(49)
|
|
|
|
}
|
|
|
|
ReceptacleTypeEnumeration ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The types of outlet receptacle."
|
|
SYNTAX INTEGER { receptacleOTHER(-1),
|
|
receptacleNONE(0),
|
|
receptacleBS1363(1),
|
|
receptacle56P532(3),
|
|
receptacleCS8364C(4),
|
|
receptacleIEC320C13(5),
|
|
receptacleIEC320C19(6),
|
|
receptacleIEC603093WIRE250V16A(7),
|
|
receptacleIEC603093WIRE250V20A(8),
|
|
receptacleIEC603093WIRE250V30A(9),
|
|
receptacleIEC603093WIRE250V32A(10),
|
|
receptacleIEC603093WIRE250V60A(11),
|
|
receptacleIEC603093WIRE250V63A(12),
|
|
receptacleIEC603093WIRE250V100A(13),
|
|
receptacleIEC603093WIRE250V125A(14),
|
|
receptacleIEC603094WIRE250V20A(15),
|
|
receptacleIEC603094WIRE250V30A(16),
|
|
receptacleIEC603094WIRE250V60A(17),
|
|
receptacleIEC603094WIRE250V100A(18),
|
|
receptacleIEC603095WIRE208V20A(23),
|
|
receptacleIEC603095WIRE208V30A(24),
|
|
receptacleIEC603095WIRE208V60A(25),
|
|
receptacleIEC603095WIRE208V100A(26),
|
|
receptacleIEC603095WIRE415V16A(27),
|
|
receptacleIEC603095WIRE415V32A(28),
|
|
receptacleIEC603095WIRE415V63A(29),
|
|
receptacleIEC603095WIRE415V125A(30),
|
|
receptacleIEC603095WIRE480V20A(31),
|
|
receptacleIEC603095WIRE480V30A(32),
|
|
receptacleIEC603095WIRE480V60A(33),
|
|
receptacleIEC603095WIRE480V100A(34),
|
|
receptacleNEMA515R(35),
|
|
receptacleNEMAL515R(36),
|
|
receptacleNEMA520R(37),
|
|
receptacleNEMAL520R(38),
|
|
receptacleNEMAL530R(39),
|
|
receptacleNEMAL615R(40),
|
|
receptacleNEMAL620R(41),
|
|
receptacleNEMAL630R(42),
|
|
receptacleNEMAL1520R(43),
|
|
receptacleNEMAL1530R(44),
|
|
receptacleNEMAL2120RP(45),
|
|
receptacleNEMAL2130R(46),
|
|
receptacleSCHUKOTYPEE(47),
|
|
receptacleSCHUKOTYPEF(48)
|
|
}
|
|
|
|
OverCurrentProtectorTypeEnumeration ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The types of overcurrent protectors."
|
|
SYNTAX INTEGER { ocpBREAKER1POLE(1),
|
|
ocpBREAKER2POLE(2),
|
|
ocpBREAKER3POLE(3),
|
|
ocpFUSE(4),
|
|
ocpFUSEPAIR(5),
|
|
ocpRCBO2POLE(6),
|
|
ocpRCBO3POLE(7),
|
|
ocpRCBO4POLE(8)
|
|
}
|
|
|
|
|
|
BoardTypeEnumeration ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The types of boards."
|
|
SYNTAX INTEGER { mainController(1),
|
|
inletController(2),
|
|
outletController(3),
|
|
meteringController(4)
|
|
}
|
|
|
|
|
|
OutletSwitchingOperationsEnumeration ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The switching operations on an outlet."
|
|
SYNTAX INTEGER { off(0),
|
|
on(1),
|
|
cycle(2)
|
|
}
|
|
|
|
|
|
|
|
|
|
SensorUnitsEnumeration ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sensor units."
|
|
SYNTAX INTEGER { none(-1),
|
|
other(0),
|
|
volt(1),
|
|
amp(2),
|
|
watt(3),
|
|
voltamp(4),
|
|
wattHour(5),
|
|
voltampHour(6),
|
|
degreeC(7),
|
|
hertz(8),
|
|
percent(9),
|
|
meterpersec(10),
|
|
pascal(11),
|
|
psi(12),
|
|
g(13),
|
|
degreeF(14),
|
|
feet(15),
|
|
inches(16),
|
|
cm(17),
|
|
meters(18),
|
|
rpm(19),
|
|
degrees(20),
|
|
lux(21)
|
|
}
|
|
|
|
DaisychainMemberTypeEnumeration ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The daisy chain member type."
|
|
SYNTAX INTEGER { standalone(0),
|
|
master(1),
|
|
slave(2)
|
|
}
|
|
|
|
|
|
URL ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "255a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A Uniform Resource Locator (URL), as defined in RFC1738."
|
|
SYNTAX OCTET STRING (SIZE (0..255))
|
|
|
|
|
|
GlobalOutletStateOnStartupEnumeration ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The global outlet state on device start up; can be overridden per outlet."
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1),
|
|
lastKnownState(2)
|
|
}
|
|
|
|
OutletStateOnStartupEnumeration ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The outlet state on device start up; this overrides the global value."
|
|
SYNTAX INTEGER { off(0),
|
|
on(1),
|
|
lastKnownState(2),
|
|
globalOutletStateOnStartup(3)
|
|
}
|
|
|
|
|
|
ExternalSensorsZCoordinateUnitsEnumeration ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The units of the external Sensor Z Coordinate.
|
|
rackUnits implies that the Z Coordinate for all external sensors
|
|
is in rack Units (U)
|
|
text implies that the Z Coordinate for all external sensors
|
|
is a text string (label) "
|
|
SYNTAX INTEGER { rackUnits(0),
|
|
text(1)
|
|
}
|
|
|
|
|
|
|
|
HundredthsOfAPercentage ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "d"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Data type for reporting values in hundredths of percentage, i.e. 0.01 %."
|
|
SYNTAX Unsigned32 (0..10000)
|
|
|
|
DeviceIdentificationParameterEnumeration ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The configurable parameters."
|
|
SYNTAX INTEGER { pduName(0),
|
|
sysContact(1),
|
|
sysName(2),
|
|
sysLocation(3)
|
|
}
|
|
|
|
|
|
TransferSwitchTransferReasonEnumeration ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Transfer Switch Transfer Reason"
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
startup(1),
|
|
manualTransfer(2),
|
|
automaticReTransfer(3),
|
|
powerFailure(4),
|
|
powerQuality(5),
|
|
overloadAlarm(6),
|
|
overheatAlarm(7),
|
|
internalFailure(8)
|
|
}
|
|
|
|
ProductTypeEnumeration ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The product types."
|
|
SYNTAX INTEGER { rackPdu(0),
|
|
bcm(1),
|
|
transferSwitch(2)
|
|
}
|
|
|
|
RelayPowerLossBehaviorEnumeration ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of relay behavior on power loss."
|
|
SYNTAX INTEGER {
|
|
nonLatching(0),
|
|
latching(1)
|
|
}
|
|
|
|
|
|
DeviceCascadeTypeEnumeration ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of configured cascading on this device."
|
|
SYNTAX INTEGER {
|
|
bridging(0),
|
|
portForwarding(1)
|
|
}
|
|
|
|
PeripheralDeviceFirmwareUpdateStateEnumeration ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The state of an peripheral device firmware update."
|
|
SYNTAX INTEGER { started(1),
|
|
successful(2),
|
|
failed(3)
|
|
}
|
|
|
|
-- the Unit group
|
|
|
|
-- Implementation for managing the PDUs
|
|
|
|
pduCount OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of PDUs"
|
|
::= { configuration 1 }
|
|
|
|
|
|
-- the Nameplate table
|
|
|
|
-- The Nameplate table contains information on the PDU's nameplate.
|
|
|
|
|
|
nameplateTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF NameplateEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of PDU nameplate entries. The number of
|
|
entries is given by the value of pduCount."
|
|
::= { unit 1 }
|
|
|
|
nameplateEntry OBJECT-TYPE
|
|
SYNTAX NameplateEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry providing PDU nameplate information."
|
|
INDEX { pduId }
|
|
::= { nameplateTable 1 }
|
|
|
|
NameplateEntryStruct ::= SEQUENCE { pduId Integer32,
|
|
pduManufacturer DisplayString,
|
|
pduModel DisplayString,
|
|
pduSerialNumber DisplayString,
|
|
pduRatedVoltage DisplayString,
|
|
pduRatedCurrent DisplayString,
|
|
pduRatedFrequency DisplayString,
|
|
pduRatedVA DisplayString,
|
|
pduImage URL
|
|
|
|
}
|
|
|
|
pduId OBJECT-TYPE
|
|
SYNTAX Integer32(1..256)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value for each PDU. Its value
|
|
ranges between 1 and the value of pduCount."
|
|
::= { nameplateEntry 1 }
|
|
|
|
pduManufacturer OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The PDU manaufacturer."
|
|
::= { nameplateEntry 2 }
|
|
|
|
pduModel OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The PDU model."
|
|
::= { nameplateEntry 3 }
|
|
|
|
|
|
pduSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The PDU serial Number."
|
|
::= { nameplateEntry 4 }
|
|
|
|
|
|
pduRatedVoltage OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The PDU voltage rating."
|
|
::= { nameplateEntry 5 }
|
|
|
|
|
|
pduRatedCurrent OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The PDU current rating."
|
|
::= { nameplateEntry 6 }
|
|
|
|
pduRatedFrequency OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The PDU frequency rating."
|
|
::= { nameplateEntry 7 }
|
|
|
|
|
|
pduRatedVA OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The PDU VA (VoltAmps) rating."
|
|
::= { nameplateEntry 8 }
|
|
|
|
|
|
pduImage OBJECT-TYPE
|
|
SYNTAX URL
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The URL of the wiring diagram for this PDU."
|
|
|
|
::= { nameplateEntry 9}
|
|
|
|
|
|
|
|
-- the UnitConfiguration table
|
|
|
|
-- The UnitConfiguration table contains information on the PDU's configuration.
|
|
|
|
|
|
unitConfigurationTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UnitConfigurationEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of PDU configuration entries. The number of
|
|
entries is given by the value of pduCount."
|
|
::= { unit 2 }
|
|
|
|
unitConfigurationEntry OBJECT-TYPE
|
|
SYNTAX UnitConfigurationEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing configuration objects for a particular PDU."
|
|
INDEX { pduId }
|
|
::= { unitConfigurationTable 1 }
|
|
|
|
UnitConfigurationEntryStruct ::= SEQUENCE {
|
|
inletCount Integer32,
|
|
overCurrentProtectorCount Integer32,
|
|
outletCount Integer32,
|
|
inletControllerCount Integer32,
|
|
outletControllerCount Integer32,
|
|
externalSensorCount Integer32,
|
|
pxIPAddress IpAddress,
|
|
netmask IpAddress,
|
|
gateway IpAddress,
|
|
pxMACAddress MacAddress,
|
|
utcOffset DisplayString,
|
|
pduName DisplayString,
|
|
externalSensorsZCoordinateUnits ExternalSensorsZCoordinateUnitsEnumeration,
|
|
unitDeviceCapabilities BITS,
|
|
outletSequencingDelay Unsigned32,
|
|
globalOutletPowerCyclingPowerOffPeriod Unsigned32,
|
|
globalOutletStateOnStartup GlobalOutletStateOnStartupEnumeration,
|
|
outletPowerupSequence DisplayString,
|
|
pduPowerCyclingPowerOffPeriod Unsigned32,
|
|
pduDaisychainMemberType DaisychainMemberTypeEnumeration,
|
|
managedExternalSensorCount Integer32,
|
|
pxInetAddressType InetAddressType,
|
|
pxInetIPAddress InetAddress,
|
|
pxInetNetmask InetAddress,
|
|
pxInetGateway InetAddress,
|
|
loadShedding TruthValue,
|
|
serverCount Integer32,
|
|
inrushGuardDelay Unsigned32,
|
|
cascadedDeviceConnected TruthValue,
|
|
synchronizeWithNTPServer TruthValue,
|
|
useDHCPProvidedNTPServer TruthValue,
|
|
firstNTPServerAddressType InetAddressType,
|
|
firstNTPServerAddress InetAddress,
|
|
secondNTPServerAddressType InetAddressType,
|
|
secondNTPServerAddress InetAddress,
|
|
wireCount Integer32,
|
|
transferSwitchCount Integer32,
|
|
productType ProductTypeEnumeration,
|
|
meteringControllerCount Integer32,
|
|
relayBehaviorOnPowerLoss RelayPowerLossBehaviorEnumeration,
|
|
deviceCascadeType DeviceCascadeTypeEnumeration,
|
|
deviceCascadePosition Integer32,
|
|
peripheralDevicesAutoManagement TruthValue,
|
|
frontPanelOutletSwitching TruthValue,
|
|
frontPanelRCMSelfTest TruthValue,
|
|
frontPanelActuatorControl TruthValue
|
|
}
|
|
|
|
|
|
|
|
inletCount OBJECT-TYPE
|
|
SYNTAX Integer32(1..256)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of inlets."
|
|
::= { unitConfigurationEntry 2 }
|
|
|
|
overCurrentProtectorCount OBJECT-TYPE
|
|
SYNTAX Integer32(0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of overcurrent protectors."
|
|
::= { unitConfigurationEntry 3 }
|
|
|
|
outletCount OBJECT-TYPE
|
|
SYNTAX Integer32(1..256)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of outlets."
|
|
::= { unitConfigurationEntry 4 }
|
|
|
|
inletControllerCount OBJECT-TYPE
|
|
SYNTAX Integer32(0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of inlet controllers."
|
|
::= { unitConfigurationEntry 5 }
|
|
|
|
|
|
outletControllerCount OBJECT-TYPE
|
|
SYNTAX Integer32(0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of outlet controllers."
|
|
::= { unitConfigurationEntry 6 }
|
|
|
|
externalSensorCount OBJECT-TYPE
|
|
SYNTAX Integer32(0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of external sensors."
|
|
::= { unitConfigurationEntry 7 }
|
|
|
|
|
|
pxIPAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The current IP address. A value of 0.0.0.0 indicates an error
|
|
or an unset option."
|
|
::= { unitConfigurationEntry 8 }
|
|
|
|
netmask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The current netmask. A value of 0.0.0.0 indicates an error
|
|
or an unset option."
|
|
::= { unitConfigurationEntry 9 }
|
|
|
|
|
|
gateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The current gateway. A value of 0.0.0.0 indicates an error
|
|
or an unset option."
|
|
::= { unitConfigurationEntry 10 }
|
|
|
|
pxMACAddress OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current MAC address."
|
|
::= { unitConfigurationEntry 11 }
|
|
|
|
|
|
utcOffset OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current UTC offset."
|
|
::= { unitConfigurationEntry 12 }
|
|
|
|
pduName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The user-defined name for the PDU."
|
|
::= { unitConfigurationEntry 13 }
|
|
|
|
|
|
|
|
|
|
|
|
|
|
externalSensorsZCoordinateUnits OBJECT-TYPE
|
|
SYNTAX ExternalSensorsZCoordinateUnitsEnumeration
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"External Sensor Z Coordinate units: Freeform Text or Rack Units (U)
|
|
Default is U."
|
|
::= { unitConfigurationEntry 34 }
|
|
|
|
unitDeviceCapabilities OBJECT-TYPE
|
|
SYNTAX BITS{
|
|
i1smpsStatus(45),
|
|
i2smpsStatus(46)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A bit string which indicates which unit sensors are available."
|
|
::= { unitConfigurationEntry 35 }
|
|
|
|
outletSequencingDelay OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"It is deprecated. This is an alias for inrushGuardDelay
|
|
"
|
|
::= { unitConfigurationEntry 36 }
|
|
|
|
|
|
globalOutletPowerCyclingPowerOffPeriod OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The power-off period when an outlet is cycled;
|
|
applies to all outlets unless overridden at the outlet level;
|
|
specified in seconds;
|
|
0 <= value <= 3600 seconds."
|
|
::= { unitConfigurationEntry 37 }
|
|
|
|
|
|
globalOutletStateOnStartup OBJECT-TYPE
|
|
SYNTAX GlobalOutletStateOnStartupEnumeration
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The outlet state on device startup; applies to all outlets
|
|
unless overridden at the outlet level.
|
|
Note that this value is ignored if relayBehaviorOnPowerLoss is set to latching."
|
|
::= { unitConfigurationEntry 38 }
|
|
|
|
outletPowerupSequence OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sequence in which will the outlets will be switched on under the following conditions.
|
|
1) Switch all outlets on operation is executed
|
|
2) Power to the PDU is cycled
|
|
String must consist of a comma separated sequence of the outlet numbers and
|
|
all outlet numbers must be included. The numbers entered must be a permutation of the numbers
|
|
1,2,3,-outletnumber.
|
|
Example for a 12 outlet PDU: 1,12,3,5,6,7,10,2,4,11,9,8.
|
|
|
|
The per outlet sequence delays are defined as outletSequenceDelay in the outletConfigurationTable
|
|
"
|
|
::= { unitConfigurationEntry 39 }
|
|
|
|
|
|
pduPowerCyclingPowerOffPeriod OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When power to the PX is cycled (either manually or because of a
|
|
temporary power loss), this number determines how many seconds the
|
|
PX will wait before it provides power to the outlets.
|
|
specified in seconds:
|
|
0 <= value <= 3600 seconds.
|
|
Note that this value is ignored if relayBehaviorOnPowerLoss is set to latching."
|
|
::= { unitConfigurationEntry 40 }
|
|
|
|
|
|
pduDaisychainMemberType OBJECT-TYPE
|
|
SYNTAX DaisychainMemberTypeEnumeration
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The daisy chain member type."
|
|
::= { unitConfigurationEntry 41 }
|
|
|
|
|
|
managedExternalSensorCount OBJECT-TYPE
|
|
SYNTAX Integer32(0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of managed external sensors "
|
|
::= { unitConfigurationEntry 42 }
|
|
|
|
|
|
pxInetAddressType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The type of address format
|
|
This object is deprecated in favor of ipAddressTable from the IP-MIB (rfc4293)."
|
|
::= { unitConfigurationEntry 50 }
|
|
|
|
|
|
pxInetIPAddress OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The current IP address. A value of 0.0.0.0 indicates an error
|
|
or an unset option.
|
|
This object is deprecated in favor of ipAddressTable from the IP-MIB (rfc4293).
|
|
For IPv6, its value is 0.0.0.0 "
|
|
::= { unitConfigurationEntry 51 }
|
|
|
|
pxInetNetmask OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The current netmask. A value of 0.0.0.0 indicates an error
|
|
or an unset option.
|
|
This object is deprecated in favor of ipAddressTable from the IP-MIB (rfc4293).
|
|
For IPv6, its value is 0.0.0.0 "
|
|
::= { unitConfigurationEntry 52 }
|
|
|
|
|
|
pxInetGateway OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The current gateway. A value of 0.0.0.0 indicates an error
|
|
or an unset option.
|
|
This object is deprecated in favor of ipAddressTable from the IP-MIB (rfc4293).
|
|
For IPv6, its value is 0.0.0.0 "
|
|
::= { unitConfigurationEntry 53 }
|
|
|
|
loadShedding OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enter/Exit Load Shedding Mode"
|
|
::= { unitConfigurationEntry 55 }
|
|
|
|
|
|
serverCount OBJECT-TYPE
|
|
SYNTAX Integer32(0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of servers"
|
|
::= { unitConfigurationEntry 56 }
|
|
|
|
|
|
inrushGuardDelay OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time interval between switching on two outlets;
|
|
specified in milliseconds;
|
|
100 <= value <= 100000 milliseconds."
|
|
::= { unitConfigurationEntry 57 }
|
|
|
|
|
|
cascadedDeviceConnected OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether another PX2 is connected using an USB cable to
|
|
the USB-A port of this PX2 in a cascaded configuration.
|
|
true: Connected
|
|
false: Not Connected"
|
|
::= { unitConfigurationEntry 58 }
|
|
|
|
|
|
|
|
synchronizeWithNTPServer OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Will time be obtained using NTP?
|
|
true: time will be obtained using NTP servers
|
|
false: time will not be obtained using NTP servers
|
|
Deafault is false."
|
|
|
|
::= { unitConfigurationEntry 59 }
|
|
|
|
useDHCPProvidedNTPServer OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Will the NTP server addresses be provided by DHCP/BOOTP?
|
|
This is used only if synchronizeWithNTPServer is enabled
|
|
Default is enabled, i.e. DHCP provided NTP servers will be used "
|
|
|
|
::= { unitConfigurationEntry 60 }
|
|
|
|
firstNTPServerAddressType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Represents the type of the corresponding instance
|
|
of firstNTPServerAddress object."
|
|
DEFVAL { ipv4 }
|
|
::= { unitConfigurationEntry 61 }
|
|
|
|
firstNTPServerAddress OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The address of the primary ntp server."
|
|
::= { unitConfigurationEntry 62 }
|
|
|
|
|
|
secondNTPServerAddressType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Represents the type of the corresponding instance
|
|
of secondNTPServerAddress object.
|
|
Default is ipv4"
|
|
|
|
::= { unitConfigurationEntry 63 }
|
|
|
|
secondNTPServerAddress OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The address of the second ntp server."
|
|
::= { unitConfigurationEntry 64 }
|
|
|
|
wireCount OBJECT-TYPE
|
|
SYNTAX Integer32(0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The number of wires."
|
|
::= { unitConfigurationEntry 65 }
|
|
|
|
transferSwitchCount OBJECT-TYPE
|
|
SYNTAX Integer32(0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of transfer switches."
|
|
::= { unitConfigurationEntry 66 }
|
|
|
|
|
|
productType OBJECT-TYPE
|
|
SYNTAX ProductTypeEnumeration
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The product type.
|
|
Is this product a PDU, STS, BCM,...?
|
|
"
|
|
::= { unitConfigurationEntry 67}
|
|
|
|
|
|
meteringControllerCount OBJECT-TYPE
|
|
SYNTAX Integer32(0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of metering controllers."
|
|
::= { unitConfigurationEntry 68 }
|
|
|
|
relayBehaviorOnPowerLoss OBJECT-TYPE
|
|
SYNTAX RelayPowerLossBehaviorEnumeration
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The relay behavior on power loss."
|
|
::= { unitConfigurationEntry 69}
|
|
|
|
deviceCascadeType OBJECT-TYPE
|
|
SYNTAX DeviceCascadeTypeEnumeration
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The configured type of cascading:
|
|
default is bridging.
|
|
This can be set only if the unit is the master."
|
|
::= { unitConfigurationEntry 70}
|
|
|
|
deviceCascadePosition OBJECT-TYPE
|
|
SYNTAX Integer32(0..99)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The position of the device in the cascaded chain.
|
|
0: master
|
|
>= 1: slaves "
|
|
::= { unitConfigurationEntry 71 }
|
|
|
|
peripheralDevicesAutoManagement OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Auto-management enabled state for peripheral devices."
|
|
::= { unitConfigurationEntry 72}
|
|
|
|
frontPanelOutletSwitching OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enables/disables switching of outlets using the PDU front panel."
|
|
::= { unitConfigurationEntry 73}
|
|
|
|
frontPanelRCMSelfTest OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enables/disables front panel RCM self-test."
|
|
::= { unitConfigurationEntry 74}
|
|
|
|
frontPanelActuatorControl OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enables/disables front panel peripheral actuator control."
|
|
::= { unitConfigurationEntry 75}
|
|
|
|
-- The ControllerConfiguration table contains information on the controllers in the PDU
|
|
|
|
|
|
controllerConfigurationTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ControllerConfigurationEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of entries for the boards in each PDU. The number of
|
|
entries is given by the value of
|
|
inletControllerCount + outletControllerCount + 1 (for main controller board)."
|
|
::= { unit 3}
|
|
|
|
controllerConfigurationEntry OBJECT-TYPE
|
|
SYNTAX ControllerConfigurationEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing objects for a controller."
|
|
INDEX { pduId, boardType, boardIndex }
|
|
::= { controllerConfigurationTable 1 }
|
|
|
|
ControllerConfigurationEntryStruct ::= SEQUENCE {
|
|
boardType BoardTypeEnumeration,
|
|
boardIndex Integer32,
|
|
boardVersion DisplayString,
|
|
boardFirmwareVersion DisplayString,
|
|
boardFirmwareTimeStamp Unsigned32
|
|
}
|
|
|
|
|
|
|
|
boardType OBJECT-TYPE
|
|
SYNTAX BoardTypeEnumeration
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of board."
|
|
::= { controllerConfigurationEntry 1 }
|
|
|
|
boardIndex OBJECT-TYPE
|
|
SYNTAX Integer32(1..256)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value for each controller. Its value
|
|
ranges between 1 and the value of
|
|
inletControllerCount + outletControllerCount + 1."
|
|
::= { controllerConfigurationEntry 2 }
|
|
|
|
boardVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The board hardware version."
|
|
::= { controllerConfigurationEntry 4 }
|
|
|
|
boardFirmwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The firmware version."
|
|
::= { controllerConfigurationEntry 6 }
|
|
|
|
boardFirmwareTimeStamp OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time when the board firmware was updated in UNIX(epoch)time.
|
|
It is measured in seconds relative to January 1, 1970 (midnight UTC/GMT),
|
|
i.e a value of 0 indicates January 1, 1970 (midnight UTC/GMT)."
|
|
::= { controllerConfigurationEntry 8 }
|
|
|
|
|
|
|
|
-- The LogConfiguration table contains information on the logs in the PDU.
|
|
|
|
|
|
logConfigurationTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF LogConfigurationEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of parameters for the data logging feature. The number of
|
|
entries is given by the value of pduCount."
|
|
::= { unit 4}
|
|
|
|
logConfigurationEntry OBJECT-TYPE
|
|
SYNTAX LogConfigurationEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing data logging parameters
|
|
for a particular PDU."
|
|
INDEX { pduId }
|
|
::= { logConfigurationTable 1 }
|
|
|
|
LogConfigurationEntryStruct ::= SEQUENCE {
|
|
dataLogging TruthValue,
|
|
measurementPeriod Integer32,
|
|
measurementsPerLogEntry Integer32,
|
|
logSize Integer32,
|
|
dataLoggingEnableForAllSensors TruthValue
|
|
}
|
|
|
|
|
|
dataLogging OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Data Retrieval: enabled/disabled."
|
|
::= { logConfigurationEntry 1 }
|
|
|
|
measurementPeriod OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Data Collection periodicity. This is the periodicity of the data collected by the PX.
|
|
This value is fixed at 1 second."
|
|
::= { logConfigurationEntry 2 }
|
|
|
|
|
|
measurementsPerLogEntry OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of measurements used for each entry in the log."
|
|
::= { logConfigurationEntry 3 }
|
|
|
|
logSize OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of entries in the log."
|
|
::= { logConfigurationEntry 4 }
|
|
|
|
|
|
dataLoggingEnableForAllSensors OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operation to control data logging for all sensors.
|
|
If this OID is set to true, then all xxxSensorLogAvailable are set to true
|
|
If this OID is set to false, then all xxxSensorLogAvailable are set to false
|
|
|
|
"
|
|
::= { logConfigurationEntry 5 }
|
|
|
|
|
|
|
|
-- the TrapInformation
|
|
|
|
-- The TrapInformation table defines information sent in the traps.
|
|
|
|
|
|
|
|
trapInformationTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TrapInformationEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of Trap Information entries. The number of
|
|
entries is given by the value of pduCount."
|
|
::= { trapInformation 1 }
|
|
|
|
trapInformationEntry OBJECT-TYPE
|
|
SYNTAX TrapInformationEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing objects used in traps."
|
|
INDEX { pduId }
|
|
::= { trapInformationTable 1 }
|
|
|
|
TrapInformationEntryStruct ::= SEQUENCE {
|
|
userName DisplayString,
|
|
targetUser DisplayString,
|
|
imageVersion DisplayString,
|
|
roleName DisplayString,
|
|
smtpMessageRecipients DisplayString,
|
|
smtpServer DisplayString
|
|
}
|
|
|
|
|
|
|
|
userName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The user currently logged in."
|
|
::= { trapInformationEntry 2 }
|
|
|
|
targetUser OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The user added, deleted, or modified."
|
|
::= { trapInformationEntry 3 }
|
|
|
|
|
|
imageVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The version of the upgrade image."
|
|
::= { trapInformationEntry 5 }
|
|
|
|
roleName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The role added, deleted, or modified."
|
|
::= { trapInformationEntry 6 }
|
|
|
|
|
|
smtpMessageRecipients OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Comma separated list of SMTP Message recipients"
|
|
::= { trapInformationEntry 7 }
|
|
|
|
|
|
smtpServer OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IP address/host name of the SMTP server"
|
|
::= { trapInformationEntry 8 }
|
|
|
|
|
|
|
|
|
|
|
|
-- Additional Information needed for traps.
|
|
|
|
|
|
|
|
oldSensorState OBJECT-TYPE
|
|
SYNTAX SensorStateEnumeration
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The old sensor state used in Sensor State Transition traps."
|
|
::= { trapInformation 2}
|
|
|
|
pduNumber OBJECT-TYPE
|
|
SYNTAX Integer32(1..256)
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value for each PDU. Its value
|
|
ranges between 1 and the value of pduCount."
|
|
::= { trapInformation 3 }
|
|
|
|
|
|
|
|
|
|
inletPoleNumber OBJECT-TYPE
|
|
SYNTAX Integer32(1..256)
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value for each inlet Pole. Its value
|
|
ranges between 1 and the value of inletPoleCount."
|
|
::= { trapInformation 5 }
|
|
|
|
|
|
|
|
|
|
|
|
outletPoleNumber OBJECT-TYPE
|
|
SYNTAX Integer32(1..256)
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value for each outlet Pole. Its value
|
|
ranges between 1 and the value of outletPoleCount."
|
|
::= { trapInformation 7 }
|
|
|
|
|
|
|
|
externalSensorNumber OBJECT-TYPE
|
|
SYNTAX Integer32(1..256)
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value for each external sensor. Its value
|
|
ranges between 1 and the value of externalSensorCount."
|
|
::= { trapInformation 8 }
|
|
|
|
|
|
|
|
|
|
|
|
typeOfSensor OBJECT-TYPE
|
|
SYNTAX SensorTypeEnumeration
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of sensor."
|
|
::= { trapInformation 10 }
|
|
|
|
|
|
errorDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Description of the Error"
|
|
::= { trapInformation 11 }
|
|
|
|
|
|
deviceChangedParameter OBJECT-TYPE
|
|
SYNTAX DeviceIdentificationParameterEnumeration
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Description of the parameter(s) that changed.
|
|
"
|
|
::= { trapInformation 12 }
|
|
|
|
|
|
changedParameterNewValue OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The new value of the changed parameter "
|
|
::= { trapInformation 13 }
|
|
|
|
|
|
lhxSupportEnabled OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The new enabled state for Schroff LHX Support."
|
|
::= { trapInformation 14 }
|
|
|
|
|
|
|
|
webcamModel OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The model of the Webcam "
|
|
::= { trapInformation 15 }
|
|
|
|
|
|
webcamConnectionPort OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The port to which the Webcam is connected "
|
|
::= { trapInformation 16 }
|
|
|
|
agentInetPortNumber OBJECT-TYPE
|
|
SYNTAX InetPortNumber
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UDP port number used for accessing
|
|
the SNMP agent on the device.
|
|
Examples:
|
|
If deviceCascadeType is portForwarding, then
|
|
master: 50500
|
|
slave 1:50501
|
|
slave 2: 50502
|
|
......
|
|
If cascading mode is not portForwarding and default (Standard) ports are being used, then
|
|
port: 161
|
|
|
|
"
|
|
::= { trapInformation 18 }
|
|
|
|
peripheralDeviceRomcode OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Romcode of an peripheral device"
|
|
::= { trapInformation 19 }
|
|
|
|
|
|
peripheralDeviceFirmwareUpdateState OBJECT-TYPE
|
|
SYNTAX PeripheralDeviceFirmwareUpdateStateEnumeration
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The firmware update state of an peripheral device"
|
|
::= { trapInformation 20 }
|
|
|
|
|
|
-- the unitSensorConfiguration table
|
|
|
|
-- The unitSensorConfiguration table contains information on the PDU's unit Sensors.
|
|
|
|
|
|
unitSensorConfigurationTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UnitSensorConfigurationEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of unit level sensors for a PDU."
|
|
::= { unit 5 }
|
|
|
|
unitSensorConfigurationEntry OBJECT-TYPE
|
|
SYNTAX UnitSensorConfigurationEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing unit sensor parameters."
|
|
INDEX { pduId, sensorType }
|
|
::= { unitSensorConfigurationTable 1 }
|
|
|
|
UnitSensorConfigurationEntryStruct ::= SEQUENCE {sensorType SensorTypeEnumeration,
|
|
unitSensorLogAvailable TruthValue,
|
|
unitSensorUnits SensorUnitsEnumeration,
|
|
unitSensorDecimalDigits Unsigned32,
|
|
unitSensorAccuracy HundredthsOfAPercentage,
|
|
unitSensorResolution Unsigned32,
|
|
unitSensorTolerance Unsigned32,
|
|
unitSensorMaximum Unsigned32,
|
|
unitSensorMinimum Unsigned32,
|
|
unitSensorHysteresis Unsigned32,
|
|
unitSensorStateChangeDelay Unsigned32,
|
|
unitSensorLowerCriticalThreshold Unsigned32,
|
|
unitSensorLowerWarningThreshold Unsigned32,
|
|
unitSensorUpperCriticalThreshold Unsigned32,
|
|
unitSensorUpperWarningThreshold Unsigned32,
|
|
unitSensorEnabledThresholds BITS,
|
|
unitSensorSignedMaximum Integer32,
|
|
unitSensorSignedMinimum Integer32,
|
|
unitSensorSignedLowerCriticalThreshold Integer32,
|
|
unitSensorSignedLowerWarningThreshold Integer32,
|
|
unitSensorSignedUpperCriticalThreshold Integer32,
|
|
unitSensorSignedUpperWarningThreshold Integer32
|
|
}
|
|
|
|
sensorType OBJECT-TYPE
|
|
SYNTAX SensorTypeEnumeration
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of sensor."
|
|
::= { unitSensorConfigurationEntry 1 }
|
|
|
|
unitSensorLogAvailable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Is logging enabled for the sensor?"
|
|
::= { unitSensorConfigurationEntry 4 }
|
|
|
|
unitSensorUnits OBJECT-TYPE
|
|
SYNTAX SensorUnitsEnumeration
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The units in which the sensor data is reported.
|
|
"
|
|
::= { unitSensorConfigurationEntry 6 }
|
|
|
|
unitSensorDecimalDigits OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of digits displayed to the right of the decimal point."
|
|
::= { unitSensorConfigurationEntry 7 }
|
|
|
|
unitSensorAccuracy OBJECT-TYPE
|
|
SYNTAX HundredthsOfAPercentage
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The accuracy: how close (in percent) the measurement is to the actual value."
|
|
::= { unitSensorConfigurationEntry 8 }
|
|
|
|
|
|
unitSensorResolution OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The resolution: the minimum difference between any two measured values
|
|
The value of this OID variable should be scaled by
|
|
unitSensorDecimalDigits. For example, if the value is 1 and
|
|
unitSensorDecimalDigits is 2, then actual value is 0.01."
|
|
::= { unitSensorConfigurationEntry 9 }
|
|
|
|
unitSensorTolerance OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The resolution: the difference between a sensor value and the actual value
|
|
The value of this OID variable should be scaled by
|
|
(unitSensorDecimalDigits + 1). For example, if the value is 50 and
|
|
unitSensorDecimalDigits is 2, then actual value is 0.05."
|
|
::= { unitSensorConfigurationEntry 10 }
|
|
|
|
unitSensorMaximum OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The largest possible reading as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
unitSensorDecimalDigits. For example, if the value is 1 and
|
|
unitSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is clamped if the scaled maximum exceeds 4294967295. It
|
|
is undefined for sensors which can have negative readings.
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { unitSensorConfigurationEntry 11 }
|
|
|
|
unitSensorMinimum OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The smallest possible reading as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
unitSensorDecimalDigits. For example, if the value is 1 and
|
|
unitSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is undefined for sensors which can have negative readings.
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { unitSensorConfigurationEntry 12 }
|
|
|
|
unitSensorHysteresis OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The hysteresis used for deassertions
|
|
The value of this OID variable should be scaled by
|
|
unitSensorDecimalDigits. For example, if the value is 1 and
|
|
unitSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { unitSensorConfigurationEntry 13 }
|
|
|
|
unitSensorStateChangeDelay OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The delay measured in samples before a state is asserted.
|
|
If the value is zero, then the state is asserted as soon as
|
|
it is detected; if it is non-zero, say n, then the assertion
|
|
condition must exist for n+1 consecutive samples before the corresponding
|
|
assertion event is reported.
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { unitSensorConfigurationEntry 14 }
|
|
|
|
unitSensorLowerCriticalThreshold OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower critical threshold as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
unitSensorDecimalDigits. For example, if the value is 1 and
|
|
unitSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is clamped if the scaled threshold exceeds 4294967295. It
|
|
is undefined for sensors which can have negative readings.
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { unitSensorConfigurationEntry 21 }
|
|
|
|
unitSensorLowerWarningThreshold OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower warning threshold as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
unitSensorDecimalDigits. For example, if the value is 1 and
|
|
unitSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is clamped if the scaled threshold exceeds 4294967295. It
|
|
is undefined for sensors which can have negative readings.
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { unitSensorConfigurationEntry 22 }
|
|
|
|
unitSensorUpperCriticalThreshold OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper critical threshold as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
unitSensorDecimalDigits. For example, if the value is 1 and
|
|
unitSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is clamped if the scaled threshold exceeds 4294967295. It
|
|
is undefined for sensors which can have negative readings.
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { unitSensorConfigurationEntry 23 }
|
|
|
|
unitSensorUpperWarningThreshold OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper warning threshold as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
unitSensorDecimalDigits. For example, if the value is 1 and
|
|
unitSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is clamped if the scaled threshold exceeds 4294967295. It
|
|
is undefined for sensors which can have negative readings.
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { unitSensorConfigurationEntry 24 }
|
|
|
|
unitSensorEnabledThresholds OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
lowerCritical(0),
|
|
lowerWarning(1),
|
|
upperWarning(2),
|
|
upperCritical(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A bit string which indicates which thresholds are enabled.
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { unitSensorConfigurationEntry 25 }
|
|
|
|
unitSensorSignedMaximum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The largest possible reading as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
unitSensorDecimalDigits. For example, if the value is 1 and
|
|
unitSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647).
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { unitSensorConfigurationEntry 26 }
|
|
|
|
unitSensorSignedMinimum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The smallest possible reading as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
unitSensorDecimalDigits. For example, if the value is 1 and
|
|
unitSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value determines whether to use the signed or unsigned threshold
|
|
and value columns: If the minimum is below zero the sensor can have
|
|
negative readings and the signed columns should be used.
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { unitSensorConfigurationEntry 27 }
|
|
|
|
unitSensorSignedLowerCriticalThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower critical threshold as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
unitSensorDecimalDigits. For example, if the value is 1 and
|
|
unitSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647).
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { unitSensorConfigurationEntry 28 }
|
|
|
|
unitSensorSignedLowerWarningThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower warning threshold as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
unitSensorDecimalDigits. For example, if the value is 1 and
|
|
unitSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647).
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { unitSensorConfigurationEntry 29 }
|
|
|
|
unitSensorSignedUpperCriticalThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper critical threshold as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
unitSensorDecimalDigits. For example, if the value is 1 and
|
|
unitSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647).
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { unitSensorConfigurationEntry 30 }
|
|
|
|
unitSensorSignedUpperWarningThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper warning threshold as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
unitSensorDecimalDigits. For example, if the value is 1 and
|
|
unitSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647).
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { unitSensorConfigurationEntry 31 }
|
|
|
|
|
|
|
|
-- the inletConfiguration table
|
|
|
|
-- The inletConfiguration table contains information on the PDU's inlets.
|
|
|
|
|
|
inletConfigurationTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF InletConfigurationEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of inlet configuration entries. The number of
|
|
entries is given by the value of inletCount for the PDU."
|
|
::= { inlets 3 }
|
|
|
|
inletConfigurationEntry OBJECT-TYPE
|
|
SYNTAX InletConfigurationEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing parametersfor a particular inlet."
|
|
INDEX { pduId, inletId }
|
|
::= { inletConfigurationTable 1 }
|
|
|
|
InletConfigurationEntryStruct ::= SEQUENCE {inletId Integer32,
|
|
inletLabel DisplayString,
|
|
inletName DisplayString,
|
|
inletPlug PlugTypeEnumeration,
|
|
inletPoleCount Integer32,
|
|
inletRatedVoltage DisplayString,
|
|
inletRatedCurrent DisplayString,
|
|
inletRatedFrequency DisplayString,
|
|
inletRatedVA DisplayString,
|
|
inletDeviceCapabilities BITS,
|
|
inletPoleCapabilities BITS,
|
|
inletPlugDescriptor DisplayString,
|
|
inletEnableState TruthValue,
|
|
inletRCMResidualOperatingCurrent Unsigned32
|
|
}
|
|
|
|
inletId OBJECT-TYPE
|
|
SYNTAX Integer32(1..256)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value for each inlet. Its value
|
|
ranges between 1 and the value of inletCount."
|
|
::= { inletConfigurationEntry 1 }
|
|
|
|
|
|
inletLabel OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The label on the PDU identifying the inlet."
|
|
::= { inletConfigurationEntry 2 }
|
|
|
|
inletName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The user-defined name."
|
|
::= { inletConfigurationEntry 3 }
|
|
|
|
inletPlug OBJECT-TYPE
|
|
SYNTAX PlugTypeEnumeration
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of plug/receptacle wired to the inlet."
|
|
::= { inletConfigurationEntry 4 }
|
|
|
|
inletPoleCount OBJECT-TYPE
|
|
SYNTAX Integer32(2..4)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of poles. For inlets with neutral poles, this number will
|
|
include the neutral pole; however, sensors are not supported for
|
|
neutral poles"
|
|
::= { inletConfigurationEntry 5 }
|
|
|
|
inletRatedVoltage OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The inlet voltage rating."
|
|
::= { inletConfigurationEntry 6 }
|
|
|
|
|
|
inletRatedCurrent OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The inlet current rating."
|
|
::= { inletConfigurationEntry 7 }
|
|
|
|
|
|
inletRatedFrequency OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The inlet frequency rating."
|
|
::= { inletConfigurationEntry 8 }
|
|
|
|
|
|
|
|
|
|
inletRatedVA OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The inlet VA (VoltAmps) rating."
|
|
::= { inletConfigurationEntry 9 }
|
|
|
|
|
|
|
|
inletDeviceCapabilities OBJECT-TYPE
|
|
SYNTAX BITS{
|
|
rmsCurrent(0),
|
|
peakCurrent(1),
|
|
unbalancedCurrent(2),
|
|
rmsVoltage(3),
|
|
activePower(4),
|
|
apparentPower(5),
|
|
powerFactor(6),
|
|
activeEnergy(7),
|
|
apparentEnergy(8),
|
|
surgeProtectorStatus(21),
|
|
frequency(22),
|
|
phaseAngle(23),
|
|
residualCurrent(26),
|
|
rcmState(27),
|
|
powerQuality(31)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A bit string which indicates which inlet sensors are available."
|
|
::= { inletConfigurationEntry 10 }
|
|
|
|
inletPoleCapabilities OBJECT-TYPE
|
|
SYNTAX BITS{
|
|
rmsCurrent(0),
|
|
peakCurrent(1),
|
|
rmsVoltage(3),
|
|
activePower(4),
|
|
apparentPower(5),
|
|
powerFactor(6),
|
|
activeEnergy(7),
|
|
apparentEnergy(8),
|
|
rmsVoltageLN(24)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A bit string which indicates which inletpole sensors are available."
|
|
::= { inletConfigurationEntry 11 }
|
|
|
|
inletPlugDescriptor OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Description of the Plug"
|
|
::= { inletConfigurationEntry 12 }
|
|
|
|
inletEnableState OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Is this PDU operation is enabled for this inlet?
|
|
When PDU operation is disabled the sensors for this inlet and all
|
|
children will no longer be updated, and outlet switching is no longer
|
|
allowed. This is only meaningful for multi-inlet units if one inlet
|
|
is temporarily expected to be powered down.
|
|
Disabling the inlet of a single-inlet unit is forbidden and any
|
|
attempt to do so will result in an error."
|
|
::= { inletConfigurationEntry 13 }
|
|
|
|
|
|
inletRCMResidualOperatingCurrent OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Residual Operating Current (Threshold) for the RCM State sensor.
|
|
For inlets without an RCM, any attempt to access this OID will return
|
|
NoSuchInstance error. The value of this OID is in milliamps.
|
|
"
|
|
::= { inletConfigurationEntry 14 }
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
-- The inletSensorConfiguration table contains information on the PDU's inlet Sensors.
|
|
|
|
|
|
inletSensorConfigurationTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF InletSensorConfigurationEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of configuration entries for an inlet sensor."
|
|
::= { inlets 4 }
|
|
|
|
inletSensorConfigurationEntry OBJECT-TYPE
|
|
SYNTAX InletSensorConfigurationEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing objects for configuring an inlet sensor."
|
|
INDEX { pduId, inletId, sensorType }
|
|
::= { inletSensorConfigurationTable 1 }
|
|
|
|
InletSensorConfigurationEntryStruct ::= SEQUENCE {
|
|
inletSensorLogAvailable TruthValue,
|
|
inletSensorUnits SensorUnitsEnumeration,
|
|
inletSensorDecimalDigits Unsigned32,
|
|
inletSensorAccuracy HundredthsOfAPercentage,
|
|
inletSensorResolution Unsigned32,
|
|
inletSensorTolerance Unsigned32,
|
|
inletSensorMaximum Unsigned32,
|
|
inletSensorMinimum Unsigned32,
|
|
inletSensorHysteresis Unsigned32,
|
|
inletSensorStateChangeDelay Unsigned32,
|
|
inletSensorLowerCriticalThreshold Unsigned32,
|
|
inletSensorLowerWarningThreshold Unsigned32,
|
|
inletSensorUpperCriticalThreshold Unsigned32,
|
|
inletSensorUpperWarningThreshold Unsigned32,
|
|
inletSensorEnabledThresholds BITS,
|
|
inletSensorSignedMaximum Integer32,
|
|
inletSensorSignedMinimum Integer32,
|
|
inletSensorSignedLowerCriticalThreshold Integer32,
|
|
inletSensorSignedLowerWarningThreshold Integer32,
|
|
inletSensorSignedUpperCriticalThreshold Integer32,
|
|
inletSensorSignedUpperWarningThreshold Integer32
|
|
}
|
|
|
|
inletSensorLogAvailable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Is logging enabled for the sensor?"
|
|
::= { inletSensorConfigurationEntry 4 }
|
|
|
|
inletSensorUnits OBJECT-TYPE
|
|
SYNTAX SensorUnitsEnumeration
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The base units.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. surge protector status sensors."
|
|
::= { inletSensorConfigurationEntry 6 }
|
|
|
|
inletSensorDecimalDigits OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of digits displayed to the right of the decimal point.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. surge protector status sensors."
|
|
::= { inletSensorConfigurationEntry 7 }
|
|
|
|
inletSensorAccuracy OBJECT-TYPE
|
|
SYNTAX HundredthsOfAPercentage
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The accuracy: how close (in percent) the measurement is to the actual value.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. surge protector status sensors."
|
|
::= { inletSensorConfigurationEntry 8 }
|
|
|
|
inletSensorResolution OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The resolution: the minimum difference between any two measured values
|
|
The value of this OID variable should be scaled by
|
|
inletSensorDecimalDigits. For example, if the value is 1 and
|
|
inletSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. surge protector status sensors."
|
|
::= { inletSensorConfigurationEntry 9 }
|
|
|
|
inletSensorTolerance OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The resolution: the difference between a sensor value and the actual value
|
|
The value of this OID variable should be scaled by
|
|
(inletSensorDecimalDigits + 1). For example, if the value is 50 and
|
|
inletSensorDecimalDigits is 2, then actual value is 0.05.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. surge protector status sensors."
|
|
::= { inletSensorConfigurationEntry 10 }
|
|
|
|
inletSensorMaximum OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The largest possible reading as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
inletSensorDecimalDigits. For example, if the value is 1 and
|
|
inletSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is clamped if the scaled maximum exceeds 4294967295. It
|
|
is undefined for sensors which can have negative readings.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. surge protector status sensors."
|
|
::= { inletSensorConfigurationEntry 11 }
|
|
|
|
inletSensorMinimum OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The smallest possible reading as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
inletSensorDecimalDigits. For example, if the value is 1 and
|
|
inletSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is undefined for sensors which can have negative readings.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. surge protector status sensors."
|
|
::= { inletSensorConfigurationEntry 12 }
|
|
|
|
inletSensorHysteresis OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The hysteresis used for deassertions
|
|
The value of this OID variable should be scaled by
|
|
inletSensorDecimalDigits. For example, if the value is 1 and
|
|
inletSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. surge protector status sensors."
|
|
::= { inletSensorConfigurationEntry 13 }
|
|
|
|
inletSensorStateChangeDelay OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The delay measured in samples before a state is asserted.
|
|
If the value is zero, then the state is asserted as soon as
|
|
it is detected; if it is non-zero, say n, then the assertion
|
|
condition must exist for n+1 consecutive samples before the corresponding
|
|
assertion event is reported.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. surge protector status sensors."
|
|
::= { inletSensorConfigurationEntry 14 }
|
|
|
|
inletSensorLowerCriticalThreshold OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower critical threshold as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
inletSensorDecimalDigits. For example, if the value is 1 and
|
|
inletSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is clamped if the scaled threshold exceeds 4294967295. It
|
|
is undefined for sensors which can have negative readings.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. surge protector status sensors."
|
|
::= { inletSensorConfigurationEntry 21 }
|
|
|
|
inletSensorLowerWarningThreshold OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower warning threshold as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
inletSensorDecimalDigits. For example, if the value is 1 and
|
|
inletSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is clamped if the scaled threshold exceeds 4294967295. It
|
|
is undefined for sensors which can have negative readings.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. surge protector status sensors."
|
|
::= { inletSensorConfigurationEntry 22 }
|
|
|
|
inletSensorUpperCriticalThreshold OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper critical threshold as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
inletSensorDecimalDigits. For example, if the value is 1 and
|
|
inletSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is clamped if the scaled threshold exceeds 4294967295. It
|
|
is undefined for sensors which can have negative readings.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. surge protector status sensors."
|
|
::= { inletSensorConfigurationEntry 23 }
|
|
|
|
inletSensorUpperWarningThreshold OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper warning threshold as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
inletSensorDecimalDigits. For example, if the value is 1 and
|
|
inletSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is clamped if the scaled threshold exceeds 4294967295. It
|
|
is undefined for sensors which can have negative readings.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. surge protector status sensors."
|
|
::= { inletSensorConfigurationEntry 24 }
|
|
|
|
inletSensorEnabledThresholds OBJECT-TYPE
|
|
SYNTAX BITS{
|
|
lowerCritical(0),
|
|
lowerWarning(1),
|
|
upperWarning(2),
|
|
upperCritical(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A bit string which indicates which thresholds are enabled.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. surge protector status sensors."
|
|
::= { inletSensorConfigurationEntry 25 }
|
|
|
|
inletSensorSignedMaximum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The largest possible reading as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
inletSensorDecimalDigits. For example, if the value is 1 and
|
|
inletSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647).
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. surge protector status sensors."
|
|
::= { inletSensorConfigurationEntry 26 }
|
|
|
|
inletSensorSignedMinimum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The smallest possible reading as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
inletSensorDecimalDigits. For example, if the value is 1 and
|
|
inletSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value determines whether to use the signed or unsigned threshold
|
|
and value columns: If the minimum is below zero the sensor can have
|
|
negative readings and the signed columns should be used.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. surge protector status sensors."
|
|
::= { inletSensorConfigurationEntry 27 }
|
|
|
|
inletSensorSignedLowerCriticalThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower critical threshold as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
inletSensorDecimalDigits. For example, if the value is 1 and
|
|
inletSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647).
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. surge protector status sensors."
|
|
::= { inletSensorConfigurationEntry 28 }
|
|
|
|
inletSensorSignedLowerWarningThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower warning threshold as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
inletSensorDecimalDigits. For example, if the value is 1 and
|
|
inletSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647).
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. surge protector status sensors."
|
|
::= { inletSensorConfigurationEntry 29 }
|
|
|
|
inletSensorSignedUpperCriticalThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper critical threshold as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
inletSensorDecimalDigits. For example, if the value is 1 and
|
|
inletSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647).
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. surge protector status sensors."
|
|
::= { inletSensorConfigurationEntry 30 }
|
|
|
|
inletSensorSignedUpperWarningThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper warning threshold as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
inletSensorDecimalDigits. For example, if the value is 1 and
|
|
inletSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647).
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. surge protector status sensors."
|
|
::= { inletSensorConfigurationEntry 31 }
|
|
|
|
|
|
|
|
-- The inletPoleSensorConfiguration table contains information on the PDU's inlet pole Sensors.
|
|
|
|
|
|
inletPoleSensorConfigurationTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF InletPoleSensorConfigurationEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of configuration entries for an inlet pole sensor."
|
|
::= { inlets 6 }
|
|
|
|
inletPoleSensorConfigurationEntry OBJECT-TYPE
|
|
SYNTAX InletPoleSensorConfigurationEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing objects
|
|
for configuring an inlet pole sensor."
|
|
INDEX { pduId, inletId,inletPoleIndex,sensorType }
|
|
::= { inletPoleSensorConfigurationTable 1 }
|
|
|
|
InletPoleSensorConfigurationEntryStruct ::= SEQUENCE { inletPoleIndex Integer32,
|
|
inletPoleSensorLogAvailable TruthValue,
|
|
inletPoleSensorUnits SensorUnitsEnumeration,
|
|
inletPoleSensorDecimalDigits Unsigned32,
|
|
inletPoleSensorAccuracy HundredthsOfAPercentage,
|
|
inletPoleSensorResolution Unsigned32,
|
|
inletPoleSensorTolerance Unsigned32,
|
|
inletPoleSensorMaximum Unsigned32,
|
|
inletPoleSensorMinimum Unsigned32,
|
|
inletPoleSensorHysteresis Unsigned32,
|
|
inletPoleSensorStateChangeDelay Unsigned32,
|
|
inletPoleSensorLowerCriticalThreshold Unsigned32,
|
|
inletPoleSensorLowerWarningThreshold Unsigned32,
|
|
inletPoleSensorUpperCriticalThreshold Unsigned32,
|
|
inletPoleSensorUpperWarningThreshold Unsigned32,
|
|
inletPoleSensorEnabledThresholds BITS,
|
|
inletPoleSensorSignedMaximum Integer32,
|
|
inletPoleSensorSignedMinimum Integer32,
|
|
inletPoleSensorSignedLowerCriticalThreshold Integer32,
|
|
inletPoleSensorSignedLowerWarningThreshold Integer32,
|
|
inletPoleSensorSignedUpperCriticalThreshold Integer32,
|
|
inletPoleSensorSignedUpperWarningThreshold Integer32
|
|
}
|
|
|
|
inletPoleIndex OBJECT-TYPE
|
|
SYNTAX Integer32(1..256)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value for each inlet Pole. Its value
|
|
ranges between 1 and the value of inletPoleCount."
|
|
::= { inletPoleSensorConfigurationEntry 1 }
|
|
|
|
inletPoleSensorLogAvailable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Is logging enabled for the sensor?"
|
|
::= { inletPoleSensorConfigurationEntry 4 }
|
|
|
|
|
|
inletPoleSensorUnits OBJECT-TYPE
|
|
SYNTAX SensorUnitsEnumeration
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The base units.
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { inletPoleSensorConfigurationEntry 6 }
|
|
|
|
|
|
inletPoleSensorDecimalDigits OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of digits displayed to the right of the decimal point.
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { inletPoleSensorConfigurationEntry 7 }
|
|
|
|
|
|
|
|
|
|
inletPoleSensorAccuracy OBJECT-TYPE
|
|
SYNTAX HundredthsOfAPercentage
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The accuracy: how close (in percent) the measurement is to the actual value.
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { inletPoleSensorConfigurationEntry 8 }
|
|
|
|
|
|
inletPoleSensorResolution OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The resolution: the minimum difference between any two measured values
|
|
The value of this OID variable should be scaled by
|
|
inletPoleSensorDecimalDigits. For example, if the value is 1 and
|
|
inletPoleSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { inletPoleSensorConfigurationEntry 9 }
|
|
|
|
inletPoleSensorTolerance OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The resolution: the difference between a sensor value and the actual value
|
|
The value of this OID variable should be scaled by
|
|
(inletPoleSensorDecimalDigits + 1). For example, if the value is 50 and
|
|
inletPoleSensorDecimalDigits is 2, then actual value is 0.05.
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { inletPoleSensorConfigurationEntry 10 }
|
|
|
|
inletPoleSensorMaximum OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The largest possible reading as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
inletPoleSensorDecimalDigits. For example, if the value is 1 and
|
|
inletPoleSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is clamped if the scaled maximum exceeds 4294967295. It
|
|
is undefined for sensors which can have negative readings.
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { inletPoleSensorConfigurationEntry 11 }
|
|
|
|
inletPoleSensorMinimum OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The smallest possible reading as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
inletPoleSensorDecimalDigits. For example, if the value is 1 and
|
|
inletPoleSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is undefined for sensors which can have negative readings.
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { inletPoleSensorConfigurationEntry 12 }
|
|
|
|
inletPoleSensorHysteresis OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The hysteresis used for deassertions
|
|
The value of this OID variable should be scaled by
|
|
inletPoleSensorDecimalDigits. For example, if the value is 1 and
|
|
inletPoleSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { inletPoleSensorConfigurationEntry 13 }
|
|
|
|
inletPoleSensorStateChangeDelay OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The delay measured in samples before a state is asserted.
|
|
If the value is zero, then the state is asserted as soon as
|
|
it is detected; if it is non-zero, say n, then the assertion
|
|
condition must exist for n+1 consecutive samples before the corresponding
|
|
assertion event is reported.
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { inletPoleSensorConfigurationEntry 14 }
|
|
|
|
inletPoleSensorLowerCriticalThreshold OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower critical threshold as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
inletPoleSensorDecimalDigits. For example, if the value is 1 and
|
|
inletPoleSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is clamped if the scaled threshold exceeds 4294967295. It
|
|
is undefined for sensors which can have negative readings.
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { inletPoleSensorConfigurationEntry 21 }
|
|
|
|
inletPoleSensorLowerWarningThreshold OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower warning threshold as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
inletPoleSensorDecimalDigits. For example, if the value is 1 and
|
|
inletPoleSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is clamped if the scaled threshold exceeds 4294967295. It
|
|
is undefined for sensors which can have negative readings.
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { inletPoleSensorConfigurationEntry 22 }
|
|
|
|
inletPoleSensorUpperCriticalThreshold OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper critical threshold as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
inletPoleSensorDecimalDigits. For example, if the value is 1 and
|
|
inletPoleSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is clamped if the scaled threshold exceeds 4294967295. It
|
|
is undefined for sensors which can have negative readings.
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { inletPoleSensorConfigurationEntry 23 }
|
|
|
|
inletPoleSensorUpperWarningThreshold OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper warning threshold as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
inletPoleSensorDecimalDigits. For example, if the value is 1 and
|
|
inletPoleSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is clamped if the scaled threshold exceeds 4294967295. It
|
|
is undefined for sensors which can have negative readings.
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { inletPoleSensorConfigurationEntry 24 }
|
|
|
|
inletPoleSensorEnabledThresholds OBJECT-TYPE
|
|
SYNTAX BITS{
|
|
lowerCritical(0),
|
|
lowerWarning(1),
|
|
upperWarning(2),
|
|
upperCritical(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A bit string which indicates which thresholds are enabled.
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { inletPoleSensorConfigurationEntry 25 }
|
|
|
|
inletPoleSensorSignedMaximum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The largest possible reading as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
inletPoleSensorDecimalDigits. For example, if the value is 1 and
|
|
inletPoleSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647).
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { inletPoleSensorConfigurationEntry 26 }
|
|
|
|
inletPoleSensorSignedMinimum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The smallest possible reading as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
inletPoleSensorDecimalDigits. For example, if the value is 1 and
|
|
inletPoleSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value determines whether to use the signed or unsigned threshold
|
|
and value columns: If the minimum is below zero the sensor can have
|
|
negative readings and the signed columns should be used.
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { inletPoleSensorConfigurationEntry 27 }
|
|
|
|
inletPoleSensorSignedLowerCriticalThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower critical threshold as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
inletPoleSensorDecimalDigits. For example, if the value is 1 and
|
|
inletPoleSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647).
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { inletPoleSensorConfigurationEntry 28 }
|
|
|
|
inletPoleSensorSignedLowerWarningThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower warning threshold as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
inletPoleSensorDecimalDigits. For example, if the value is 1 and
|
|
inletPoleSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647).
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { inletPoleSensorConfigurationEntry 29 }
|
|
|
|
inletPoleSensorSignedUpperCriticalThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper critical threshold as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
inletPoleSensorDecimalDigits. For example, if the value is 1 and
|
|
inletPoleSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647).
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { inletPoleSensorConfigurationEntry 30 }
|
|
|
|
inletPoleSensorSignedUpperWarningThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper warning threshold as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
inletPoleSensorDecimalDigits. For example, if the value is 1 and
|
|
inletPoleSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647).
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { inletPoleSensorConfigurationEntry 31 }
|
|
|
|
|
|
|
|
-- the overCurrentProtectorConfiguration table
|
|
|
|
-- The overCurrentProtectorConfiguration table contains information on the PDU's overcurrent protectors.
|
|
|
|
|
|
overCurrentProtectorConfigurationTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OverCurrentProtectorConfigurationEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of overCurrentProtector configuration entries. The number of
|
|
entries is given by the value of overCurrentProtectorCount for the PDU."
|
|
::= { overCurrentProtector 3 }
|
|
|
|
overCurrentProtectorConfigurationEntry OBJECT-TYPE
|
|
SYNTAX OverCurrentProtectorConfigurationEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing objects for a particular overCurrentProtector."
|
|
INDEX { pduId, overCurrentProtectorIndex }
|
|
::= { overCurrentProtectorConfigurationTable 1 }
|
|
|
|
OverCurrentProtectorConfigurationEntryStruct ::= SEQUENCE { overCurrentProtectorIndex Integer32,
|
|
overCurrentProtectorLabel DisplayString,
|
|
overCurrentProtectorName DisplayString,
|
|
overCurrentProtectorType OverCurrentProtectorTypeEnumeration,
|
|
overCurrentProtectorRatedCurrent DisplayString,
|
|
overCurrentProtectorCapabilities BITS,
|
|
overCurrentProtectorPowerSource RowPointer
|
|
}
|
|
|
|
|
|
overCurrentProtectorIndex OBJECT-TYPE
|
|
SYNTAX Integer32(1..256)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value for each overcurrent protector. Its value
|
|
ranges between 1 and the value of overCurrentProtectorCount."
|
|
::= { overCurrentProtectorConfigurationEntry 1 }
|
|
|
|
overCurrentProtectorLabel OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The label on the PDU identifying the overcurrent protector."
|
|
::= { overCurrentProtectorConfigurationEntry 2 }
|
|
|
|
overCurrentProtectorName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The user-defined name."
|
|
::= { overCurrentProtectorConfigurationEntry 3 }
|
|
|
|
overCurrentProtectorType OBJECT-TYPE
|
|
SYNTAX OverCurrentProtectorTypeEnumeration
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of overcurrent protector."
|
|
::= { overCurrentProtectorConfigurationEntry 4 }
|
|
|
|
|
|
|
|
|
|
overCurrentProtectorRatedCurrent OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current rating."
|
|
::= { overCurrentProtectorConfigurationEntry 5 }
|
|
|
|
|
|
|
|
overCurrentProtectorCapabilities OBJECT-TYPE
|
|
SYNTAX BITS{
|
|
rmsCurrent(0),
|
|
peakCurrent(1),
|
|
trip(14)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A bit string which indicates which overcurrent protector sensors are available."
|
|
::= { overCurrentProtectorConfigurationEntry 9 }
|
|
|
|
overCurrentProtectorPowerSource OBJECT-TYPE
|
|
SYNTAX RowPointer
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object allows discovery of how the PDU is wired. It indicates the
|
|
overCurrentProtector's power source which can one of the following:
|
|
overCurrentProtector
|
|
transfer switch
|
|
inlet
|
|
|
|
If the power source is an OverCurrentProtector, it
|
|
contains the OID of an overCurrentProtectorLabel in the
|
|
overCurrentProtectorConfiguration Table. The index of the OID can then be
|
|
used to reference other objects in the overCurrentProtectorConfigurationTable.
|
|
|
|
If the power source is an inlet, it contains the OID of
|
|
an inletLabel in the inletConfigurationTable. The index of the OID can
|
|
then be used to reference other objects in the inletConfigurationTable.
|
|
|
|
If the power source is a transferSwitch, it
|
|
contains the OID of a transferSwitchLabel in the
|
|
transferSwitchConfiguration Table. The index of the OID can then be
|
|
used to reference other objects in the transferSwitchConfigurationTable.
|
|
"
|
|
::= { overCurrentProtectorConfigurationEntry 10 }
|
|
|
|
|
|
|
|
|
|
-- The overCurrentProtectorSensorConfiguration table contains information on the PDU's overcurrent protector Sensors.
|
|
|
|
|
|
overCurrentProtectorSensorConfigurationTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OverCurrentProtectorSensorConfigurationEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of overCurrentProtectorSensor configuration entries."
|
|
::= { overCurrentProtector 4 }
|
|
|
|
overCurrentProtectorSensorConfigurationEntry OBJECT-TYPE
|
|
SYNTAX OverCurrentProtectorSensorConfigurationEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An overCurrentProtectorSensor entry containing objects for a
|
|
particular overCurrentProtector Sensor."
|
|
INDEX { pduId, overCurrentProtectorIndex, sensorType }
|
|
::= { overCurrentProtectorSensorConfigurationTable 1 }
|
|
|
|
OverCurrentProtectorSensorConfigurationEntryStruct ::= SEQUENCE {
|
|
overCurrentProtectorSensorLogAvailable TruthValue,
|
|
overCurrentProtectorSensorUnits SensorUnitsEnumeration,
|
|
overCurrentProtectorSensorDecimalDigits Unsigned32,
|
|
overCurrentProtectorSensorAccuracy HundredthsOfAPercentage,
|
|
overCurrentProtectorSensorResolution Unsigned32,
|
|
overCurrentProtectorSensorTolerance Unsigned32,
|
|
overCurrentProtectorSensorMaximum Unsigned32,
|
|
overCurrentProtectorSensorMinimum Unsigned32,
|
|
overCurrentProtectorSensorHysteresis Unsigned32,
|
|
overCurrentProtectorSensorStateChangeDelay Unsigned32,
|
|
overCurrentProtectorSensorLowerCriticalThreshold Unsigned32,
|
|
overCurrentProtectorSensorLowerWarningThreshold Unsigned32,
|
|
overCurrentProtectorSensorUpperCriticalThreshold Unsigned32,
|
|
overCurrentProtectorSensorUpperWarningThreshold Unsigned32,
|
|
overCurrentProtectorSensorEnabledThresholds BITS,
|
|
overCurrentProtectorSensorSignedMaximum Integer32,
|
|
overCurrentProtectorSensorSignedMinimum Integer32,
|
|
overCurrentProtectorSensorSignedLowerCriticalThreshold Integer32,
|
|
overCurrentProtectorSensorSignedLowerWarningThreshold Integer32,
|
|
overCurrentProtectorSensorSignedUpperCriticalThreshold Integer32,
|
|
overCurrentProtectorSensorSignedUpperWarningThreshold Integer32
|
|
}
|
|
|
|
overCurrentProtectorSensorLogAvailable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Is logging available for this sensor?"
|
|
::= { overCurrentProtectorSensorConfigurationEntry 4 }
|
|
|
|
overCurrentProtectorSensorUnits OBJECT-TYPE
|
|
SYNTAX SensorUnitsEnumeration
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The base units
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. trip sensors."
|
|
::= { overCurrentProtectorSensorConfigurationEntry 6 }
|
|
|
|
overCurrentProtectorSensorDecimalDigits OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of digits displayed to the right of the decimal point.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. trip sensors."
|
|
::= { overCurrentProtectorSensorConfigurationEntry 7 }
|
|
|
|
overCurrentProtectorSensorAccuracy OBJECT-TYPE
|
|
SYNTAX HundredthsOfAPercentage
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The accuracy: how close (in percent) the measurement is to the actual value
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. trip sensors."
|
|
::= { overCurrentProtectorSensorConfigurationEntry 8 }
|
|
|
|
overCurrentProtectorSensorResolution OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The resolution: the minimum difference between any two measured values
|
|
The value of this OID variable should be scaled by
|
|
overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and
|
|
overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. trip sensors."
|
|
::= { overCurrentProtectorSensorConfigurationEntry 9 }
|
|
|
|
overCurrentProtectorSensorTolerance OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The resolution: the difference between a sensor value and the actual value
|
|
The value of this OID variable should be scaled by
|
|
(overCurrentProtectorSensorDecimalDigits + 1). For example, if the value is 50 and
|
|
overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.05.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. trip sensors."
|
|
::= { overCurrentProtectorSensorConfigurationEntry 10 }
|
|
|
|
overCurrentProtectorSensorMaximum OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The largest possible reading as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and
|
|
overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is clamped if the scaled maximum exceeds 4294967295. It
|
|
is undefined for sensors which can have negative readings.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. trip sensors."
|
|
::= { overCurrentProtectorSensorConfigurationEntry 11 }
|
|
|
|
overCurrentProtectorSensorMinimum OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The smallest possible reading as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and
|
|
overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is undefined for sensors which can have negative readings.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. trip sensors."
|
|
::= { overCurrentProtectorSensorConfigurationEntry 12 }
|
|
|
|
overCurrentProtectorSensorHysteresis OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The hysteresis used for deassertions
|
|
The value of this OID variable should be scaled by
|
|
overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and
|
|
overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. trip sensors."
|
|
::= { overCurrentProtectorSensorConfigurationEntry 13 }
|
|
|
|
overCurrentProtectorSensorStateChangeDelay OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The delay measured in samples before a state is asserted.
|
|
If the value is zero, then the state is asserted as soon as
|
|
it is detected; if it is non-zero, say n, then the assertion
|
|
condition must exist for n+1 consecutive samples before the corresponding
|
|
assertion event is reported.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. trip sensors."
|
|
::= { overCurrentProtectorSensorConfigurationEntry 14 }
|
|
|
|
overCurrentProtectorSensorLowerCriticalThreshold OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower critical threshold as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and
|
|
overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is clamped if the scaled threshold exceeds 4294967295. It
|
|
is undefined for sensors which can have negative readings.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. trip sensors."
|
|
::= { overCurrentProtectorSensorConfigurationEntry 21 }
|
|
|
|
overCurrentProtectorSensorLowerWarningThreshold OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower warning threshold as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and
|
|
overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is clamped if the scaled threshold exceeds 4294967295. It
|
|
is undefined for sensors which can have negative readings.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. trip sensors."
|
|
::= { overCurrentProtectorSensorConfigurationEntry 22 }
|
|
|
|
overCurrentProtectorSensorUpperCriticalThreshold OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper critical threshold as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and
|
|
overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is clamped if the scaled threshold exceeds 4294967295. It
|
|
is undefined for sensors which can have negative readings.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. trip sensors."
|
|
::= { overCurrentProtectorSensorConfigurationEntry 23 }
|
|
|
|
overCurrentProtectorSensorUpperWarningThreshold OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper warning threshold as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and
|
|
overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is clamped if the scaled threshold exceeds 4294967295. It
|
|
is undefined for sensors which can have negative readings.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. trip sensors."
|
|
::= { overCurrentProtectorSensorConfigurationEntry 24 }
|
|
|
|
overCurrentProtectorSensorEnabledThresholds OBJECT-TYPE
|
|
SYNTAX BITS{
|
|
lowerCritical(0),
|
|
lowerWarning(1),
|
|
upperWarning(2),
|
|
upperCritical(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A bit string which indicates which thresholds are enabled.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. trip sensors."
|
|
::= { overCurrentProtectorSensorConfigurationEntry 25}
|
|
|
|
overCurrentProtectorSensorSignedMaximum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The largest possible reading as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and
|
|
overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647).
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. trip sensors."
|
|
::= { overCurrentProtectorSensorConfigurationEntry 26 }
|
|
|
|
overCurrentProtectorSensorSignedMinimum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The smallest possible reading as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and
|
|
overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value determines whether to use the signed or unsigned threshold
|
|
and value columns: If the minimum is below zero the sensor can have
|
|
negative readings and the signed columns should be used.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. trip sensors."
|
|
::= { overCurrentProtectorSensorConfigurationEntry 27 }
|
|
|
|
overCurrentProtectorSensorSignedLowerCriticalThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower critical threshold as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and
|
|
overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647).
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. trip sensors."
|
|
::= { overCurrentProtectorSensorConfigurationEntry 28 }
|
|
|
|
overCurrentProtectorSensorSignedLowerWarningThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower warning threshold as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and
|
|
overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647).
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. trip sensors."
|
|
::= { overCurrentProtectorSensorConfigurationEntry 29 }
|
|
|
|
overCurrentProtectorSensorSignedUpperCriticalThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper critical threshold as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and
|
|
overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647).
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. trip sensors."
|
|
::= { overCurrentProtectorSensorConfigurationEntry 30 }
|
|
|
|
overCurrentProtectorSensorSignedUpperWarningThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper warning threshold as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and
|
|
overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647).
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. trip sensors."
|
|
::= { overCurrentProtectorSensorConfigurationEntry 31 }
|
|
|
|
|
|
|
|
-- the outletConfiguration table
|
|
|
|
-- The outletConfiguration table contains information on the PDU's outlets.
|
|
|
|
|
|
outletConfigurationTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OutletConfigurationEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of outlet configuration entries. The number of
|
|
entries is given by the value of outletCount for the PDU."
|
|
::= { outlets 3 }
|
|
|
|
outletConfigurationEntry OBJECT-TYPE
|
|
SYNTAX OutletConfigurationEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An outlet entry containing parameters for a particular outlet."
|
|
INDEX { pduId, outletId }
|
|
::= { outletConfigurationTable 1 }
|
|
|
|
OutletConfigurationEntryStruct ::= SEQUENCE {
|
|
outletId Integer32,
|
|
outletLabel DisplayString,
|
|
outletName DisplayString,
|
|
outletReceptacle ReceptacleTypeEnumeration,
|
|
outletPoleCount Integer32,
|
|
outletRatedVoltage DisplayString,
|
|
outletRatedCurrent DisplayString,
|
|
outletRatedVA DisplayString,
|
|
outletDeviceCapabilities BITS,
|
|
outletPoleCapabilities BITS,
|
|
outletPowerCyclingPowerOffPeriod Unsigned32,
|
|
outletStateOnStartup OutletStateOnStartupEnumeration,
|
|
outletUseGlobalPowerCyclingPowerOffPeriod TruthValue,
|
|
outletSwitchable TruthValue,
|
|
outletReceptacleDescriptor DisplayString,
|
|
outletNonCritical TruthValue,
|
|
outletSequenceDelay Unsigned32,
|
|
outletPowerSource RowPointer
|
|
}
|
|
|
|
outletId OBJECT-TYPE
|
|
SYNTAX Integer32(1..256)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value for each outlet. Its value
|
|
ranges between 1 and the value of outletCount."
|
|
::= { outletConfigurationEntry 1 }
|
|
|
|
|
|
outletLabel OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The label on the PDU identifying the outlet."
|
|
::= { outletConfigurationEntry 2 }
|
|
|
|
outletName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The user-defined name."
|
|
::= { outletConfigurationEntry 3 }
|
|
|
|
outletReceptacle OBJECT-TYPE
|
|
SYNTAX ReceptacleTypeEnumeration
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The plug."
|
|
::= { outletConfigurationEntry 4 }
|
|
|
|
outletPoleCount OBJECT-TYPE
|
|
SYNTAX Integer32(2..4)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of poles."
|
|
::= { outletConfigurationEntry 5 }
|
|
|
|
outletRatedVoltage OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The outlet voltage rating."
|
|
::= { outletConfigurationEntry 6 }
|
|
|
|
|
|
outletRatedCurrent OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The outlet current rating."
|
|
::= { outletConfigurationEntry 7 }
|
|
|
|
|
|
outletRatedVA OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The outlet VA (VoltAmps) rating."
|
|
::= { outletConfigurationEntry 8 }
|
|
|
|
|
|
|
|
outletDeviceCapabilities OBJECT-TYPE
|
|
SYNTAX BITS{
|
|
rmsCurrent(0),
|
|
peakCurrent(1),
|
|
unbalancedCurrent(2),
|
|
rmsVoltage(3),
|
|
activePower(4),
|
|
apparentPower(5),
|
|
powerFactor(6),
|
|
activeEnergy(7),
|
|
apparentEnergy(8),
|
|
onOff(13),
|
|
frequency(22),
|
|
phaseAngle(23)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A bit string which indicates which outlet sensors are available."
|
|
::= { outletConfigurationEntry 10 }
|
|
|
|
outletPoleCapabilities OBJECT-TYPE
|
|
SYNTAX BITS{
|
|
rmsCurrent(0),
|
|
peakCurrent(1),
|
|
rmsVoltage(3),
|
|
activePower(4),
|
|
apparentPower(5),
|
|
powerFactor(6),
|
|
activeEnergy(7),
|
|
apparentEnergy(8),
|
|
rmsVoltageLN(24)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A bit string which indicates which outlet pole sensors are available."
|
|
::= { outletConfigurationEntry 11 }
|
|
|
|
|
|
outletPowerCyclingPowerOffPeriod OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The power-off period when an outlet is cycled;
|
|
overrides the global value;
|
|
specified in seconds;
|
|
0 <= value <= 3600 seconds."
|
|
::= { outletConfigurationEntry 12 }
|
|
|
|
|
|
outletStateOnStartup OBJECT-TYPE
|
|
SYNTAX OutletStateOnStartupEnumeration
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The outlet state on device startup;
|
|
overrides the global value.
|
|
Note that this value is ignored if
|
|
relayBehaviorOnPowerLoss is set to latching."
|
|
::= { outletConfigurationEntry 13}
|
|
|
|
|
|
outletUseGlobalPowerCyclingPowerOffPeriod OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If this true, then use globalOutletPowerCyclingPowerOffPeriod."
|
|
::= { outletConfigurationEntry 14 }
|
|
|
|
|
|
|
|
|
|
outletSwitchable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Is this outlet switchable?"
|
|
::= { outletConfigurationEntry 28 }
|
|
|
|
|
|
outletReceptacleDescriptor OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Description of the Receptacle"
|
|
::= { outletConfigurationEntry 29 }
|
|
|
|
|
|
outletNonCritical OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Is this outlet non-critical?"
|
|
::= { outletConfigurationEntry 30 }
|
|
|
|
|
|
|
|
|
|
|
|
outletSequenceDelay OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time interval between switching on this outlet and the next outlet in the
|
|
outlet sequence.
|
|
This applies to the following operations.
|
|
1) Switch all outlets on operation is executed
|
|
2) Power to the PDU is cycledThis applies only when all outlets are being switched on or cycled.
|
|
It is specified in seconds;
|
|
1 <= value <= 3600 seconds.
|
|
The actual time interval used can never be less than the inrushGuardDelay defined
|
|
in the unitConfigurationTable.
|
|
Examples:
|
|
1) inrush Guard Delay is 2 seconds and outletSequenceDelay is 5 seconds.
|
|
The time interval will be 5 seconds
|
|
2) inrush Guard Delay is 5 seconds and outletSequenceDelay is 2 seconds.
|
|
The time interval will be 5 seconds
|
|
"
|
|
::= { outletConfigurationEntry 32 }
|
|
|
|
|
|
outletPowerSource OBJECT-TYPE
|
|
SYNTAX RowPointer
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object allows discovery of how the PDU is wired. It indicates the
|
|
outlet's power source which can one of the following:
|
|
overCurrentProtector
|
|
transfer switch
|
|
inlet
|
|
|
|
If the power source is an OverCurrentProtector, it
|
|
contains the OID of an overCurrentProtectorLabel in the
|
|
overCurrentProtectorConfiguration Table. The index of the OID can then be
|
|
used to reference other objects in the overCurrentProtectorConfigurationTable.
|
|
|
|
If the power source is an inlet, it contains the OID of
|
|
an inletLabel in the inletConfigurationTable. The index of the OID can
|
|
then be used to reference other objects in the inletConfigurationTable.
|
|
|
|
If the power source is a transferSwitch, it
|
|
contains the OID of a transferSwitchLabel in the
|
|
transferSwitchConfiguration Table. The index of the OID can then be
|
|
used to reference other objects in the transferSwitchConfigurationTable.
|
|
|
|
"
|
|
::= { outletConfigurationEntry 33}
|
|
|
|
|
|
|
|
-- The outletSensorConfiguration table contains information on the PDU's inlet Sensors.
|
|
|
|
|
|
outletSensorConfigurationTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OutletSensorConfigurationEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of outlet configuration entries. The number of
|
|
entries is given by the value of outletCount for the PDU."
|
|
::= { outlets 4 }
|
|
|
|
outletSensorConfigurationEntry OBJECT-TYPE
|
|
SYNTAX OutletSensorConfigurationEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing parameters for an outlet sensor."
|
|
INDEX { pduId, outletId,sensorType }
|
|
::= { outletSensorConfigurationTable 1 }
|
|
|
|
OutletSensorConfigurationEntryStruct ::= SEQUENCE {
|
|
outletSensorLogAvailable TruthValue,
|
|
outletSensorUnits SensorUnitsEnumeration,
|
|
outletSensorDecimalDigits Unsigned32,
|
|
outletSensorAccuracy HundredthsOfAPercentage,
|
|
outletSensorResolution Unsigned32,
|
|
outletSensorTolerance Unsigned32,
|
|
outletSensorMaximum Unsigned32,
|
|
outletSensorMinimum Unsigned32,
|
|
outletSensorHysteresis Unsigned32,
|
|
outletSensorStateChangeDelay Unsigned32,
|
|
outletSensorLowerCriticalThreshold Unsigned32,
|
|
outletSensorLowerWarningThreshold Unsigned32,
|
|
outletSensorUpperCriticalThreshold Unsigned32,
|
|
outletSensorUpperWarningThreshold Unsigned32,
|
|
outletSensorEnabledThresholds BITS,
|
|
outletSensorSignedMaximum Integer32,
|
|
outletSensorSignedMinimum Integer32,
|
|
outletSensorSignedLowerCriticalThreshold Integer32,
|
|
outletSensorSignedLowerWarningThreshold Integer32,
|
|
outletSensorSignedUpperCriticalThreshold Integer32,
|
|
outletSensorSignedUpperWarningThreshold Integer32
|
|
}
|
|
|
|
outletSensorLogAvailable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Is logging available for this sensor?"
|
|
::= { outletSensorConfigurationEntry 4 }
|
|
|
|
outletSensorUnits OBJECT-TYPE
|
|
SYNTAX SensorUnitsEnumeration
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The base units.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. outlet state sensors."
|
|
::= { outletSensorConfigurationEntry 6 }
|
|
|
|
outletSensorDecimalDigits OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of digits displayed to the right of the decimal point
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. outlet state sensors."
|
|
::= { outletSensorConfigurationEntry 7 }
|
|
|
|
outletSensorAccuracy OBJECT-TYPE
|
|
SYNTAX HundredthsOfAPercentage
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The accuracy: how close (in percent) the measurement is to the actual value
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. outlet state sensors."
|
|
::= { outletSensorConfigurationEntry 8 }
|
|
|
|
outletSensorResolution OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The resolution: the minimum difference between any two measured values
|
|
The value of this OID variable should be scaled by
|
|
outletSensorDecimalDigits. For example, if the value is 1 and
|
|
outletSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. outlet state sensors."
|
|
::= { outletSensorConfigurationEntry 9 }
|
|
|
|
outletSensorTolerance OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The resolution: the difference between a sensor value and the actual value
|
|
The value of this OID variable should be scaled by
|
|
(outletSensorDecimalDigits + 1). For example, if the value is 50 and
|
|
outletSensorDecimalDigits is 2, then actual value is 0.05.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. outlet state sensors."
|
|
::= { outletSensorConfigurationEntry 10 }
|
|
|
|
outletSensorMaximum OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The largest possible reading as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
outletSensorDecimalDigits. For example, if the value is 1 and
|
|
outletSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is clamped if the scaled maximum exceeds 4294967295. It
|
|
is undefined for sensors which can have negative readings.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. outlet state sensors."
|
|
::= { outletSensorConfigurationEntry 11 }
|
|
|
|
outletSensorMinimum OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The smallest possible reading as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
outletSensorDecimalDigits. For example, if the value is 1 and
|
|
outletSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is undefined for sensors which can have negative readings.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. outlet state sensors."
|
|
::= { outletSensorConfigurationEntry 12 }
|
|
|
|
outletSensorHysteresis OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The hysteresis used for deassertions
|
|
The value of this OID variable should be scaled by
|
|
outletSensorDecimalDigits. For example, if the value is 1 and
|
|
outletSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. outlet state sensors."
|
|
::= { outletSensorConfigurationEntry 13 }
|
|
|
|
outletSensorStateChangeDelay OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The delay measured in samples before a state is asserted.
|
|
If the value is zero, then the state is asserted as soon as
|
|
it is detected; if it is non-zero, say n, then the assertion
|
|
condition must exist for n+1 consecutive samples before the corresponding
|
|
assertion event is reported.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. outlet state sensors."
|
|
::= { outletSensorConfigurationEntry 14 }
|
|
|
|
outletSensorLowerCriticalThreshold OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower critical threshold as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
outletSensorDecimalDigits. For example, if the value is 1 and
|
|
outletSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is clamped if the scaled threshold exceeds 4294967295. It
|
|
is undefined for sensors which can have negative readings.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. outlet state sensors."
|
|
::= { outletSensorConfigurationEntry 21 }
|
|
|
|
outletSensorLowerWarningThreshold OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower warning threshold as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
outletSensorDecimalDigits. For example, if the value is 1 and
|
|
outletSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is clamped if the scaled threshold exceeds 4294967295. It
|
|
is undefined for sensors which can have negative readings.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. outlet state sensors."
|
|
::= { outletSensorConfigurationEntry 22 }
|
|
|
|
outletSensorUpperCriticalThreshold OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper critical threshold as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
outletSensorDecimalDigits. For example, if the value is 1 and
|
|
outletSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is clamped if the scaled threshold exceeds 4294967295. It
|
|
is undefined for sensors which can have negative readings.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. outlet state sensors."
|
|
::= { outletSensorConfigurationEntry 23 }
|
|
|
|
outletSensorUpperWarningThreshold OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper warning threshold as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
outletSensorDecimalDigits. For example, if the value is 1 and
|
|
outletSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is clamped if the scaled threshold exceeds 4294967295. It
|
|
is undefined for sensors which can have negative readings.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. outlet state sensors."
|
|
::= { outletSensorConfigurationEntry 24 }
|
|
|
|
outletSensorEnabledThresholds OBJECT-TYPE
|
|
SYNTAX BITS{
|
|
lowerCritical(0),
|
|
lowerWarning(1),
|
|
upperWarning(2),
|
|
upperCritical(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A bit string which indicates which thresholds are enabled.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. outlet state sensors."
|
|
::= { outletSensorConfigurationEntry 25 }
|
|
|
|
outletSensorSignedMaximum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The largest possible reading as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
outletSensorDecimalDigits. For example, if the value is 1 and
|
|
outletSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647).
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. outlet state sensors."
|
|
::= { outletSensorConfigurationEntry 26 }
|
|
|
|
outletSensorSignedMinimum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The smallest possible reading as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
outletSensorDecimalDigits. For example, if the value is 1 and
|
|
outletSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value determines whether to use the signed or unsigned threshold
|
|
and value columns: If the minimum is below zero the sensor can have
|
|
negative readings and the signed columns should be used.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. outlet state sensors."
|
|
::= { outletSensorConfigurationEntry 27 }
|
|
|
|
outletSensorSignedLowerCriticalThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower critical threshold as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
outletSensorDecimalDigits. For example, if the value is 1 and
|
|
outletSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647).
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. outlet state sensors."
|
|
::= { outletSensorConfigurationEntry 28 }
|
|
|
|
outletSensorSignedLowerWarningThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower warning threshold as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
outletSensorDecimalDigits. For example, if the value is 1 and
|
|
outletSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647).
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. outlet state sensors."
|
|
::= { outletSensorConfigurationEntry 29 }
|
|
|
|
outletSensorSignedUpperCriticalThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper critical threshold as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
outletSensorDecimalDigits. For example, if the value is 1 and
|
|
outletSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647).
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. outlet state sensors."
|
|
::= { outletSensorConfigurationEntry 30 }
|
|
|
|
outletSensorSignedUpperWarningThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper warning threshold as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
outletSensorDecimalDigits. For example, if the value is 1 and
|
|
outletSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647).
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. outlet state sensors."
|
|
::= { outletSensorConfigurationEntry 31 }
|
|
|
|
|
|
|
|
-- The outletPoleSensorConfiguration table contains information on the PDU's outlet pole Sensors.
|
|
|
|
|
|
outletPoleSensorConfigurationTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OutletPoleSensorConfigurationEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of outlet pole sensor configuration entries. The number of
|
|
entries is given by the value of outletPoleCount."
|
|
::= { outlets 6 }
|
|
|
|
outletPoleSensorConfigurationEntry OBJECT-TYPE
|
|
SYNTAX OutletPoleSensorConfigurationEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing objects
|
|
for configuring an outlet pole sensor."
|
|
INDEX { pduId, outletId,outletPoleIndex,sensorType }
|
|
::= { outletPoleSensorConfigurationTable 1 }
|
|
|
|
OutletPoleSensorConfigurationEntryStruct ::= SEQUENCE { outletPoleIndex Integer32,
|
|
outletPoleSensorLogAvailable TruthValue,
|
|
outletPoleSensorUnits SensorUnitsEnumeration,
|
|
outletPoleSensorDecimalDigits Unsigned32,
|
|
outletPoleSensorAccuracy HundredthsOfAPercentage,
|
|
outletPoleSensorResolution Unsigned32,
|
|
outletPoleSensorTolerance Unsigned32,
|
|
outletPoleSensorMaximum Unsigned32,
|
|
outletPoleSensorMinimum Unsigned32,
|
|
outletPoleSensorHysteresis Unsigned32,
|
|
outletPoleSensorStateChangeDelay Unsigned32,
|
|
outletPoleSensorLowerCriticalThreshold Unsigned32,
|
|
outletPoleSensorLowerWarningThreshold Unsigned32,
|
|
outletPoleSensorUpperCriticalThreshold Unsigned32,
|
|
outletPoleSensorUpperWarningThreshold Unsigned32,
|
|
outletPoleSensorEnabledThresholds BITS,
|
|
outletPoleSensorSignedMaximum Integer32,
|
|
outletPoleSensorSignedMinimum Integer32,
|
|
outletPoleSensorSignedLowerCriticalThreshold Integer32,
|
|
outletPoleSensorSignedLowerWarningThreshold Integer32,
|
|
outletPoleSensorSignedUpperCriticalThreshold Integer32,
|
|
outletPoleSensorSignedUpperWarningThreshold Integer32
|
|
}
|
|
|
|
outletPoleIndex OBJECT-TYPE
|
|
SYNTAX Integer32(1..256)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value for each outlet Pole. Its value
|
|
ranges between 1 and the value of outletPoleCount."
|
|
::= { outletPoleSensorConfigurationEntry 1 }
|
|
|
|
outletPoleSensorLogAvailable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Is logging enabled for the sensor?"
|
|
::= { outletPoleSensorConfigurationEntry 4 }
|
|
|
|
outletPoleSensorUnits OBJECT-TYPE
|
|
SYNTAX SensorUnitsEnumeration
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The base units.
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { outletPoleSensorConfigurationEntry 6 }
|
|
|
|
outletPoleSensorDecimalDigits OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of digits displayed to the right of the decimal point.
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { outletPoleSensorConfigurationEntry 7 }
|
|
|
|
outletPoleSensorAccuracy OBJECT-TYPE
|
|
SYNTAX HundredthsOfAPercentage
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The accuracy: how close (in percent) the measurement is to the actual value.
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { outletPoleSensorConfigurationEntry 8 }
|
|
|
|
|
|
outletPoleSensorResolution OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The resolution: the minimum difference between any two measured values
|
|
The value of this OID variable should be scaled by
|
|
outletPoleSensorDecimalDigits. For example, if the value is 50 and
|
|
outletPoleSensorDecimalDigits is 2, then actual value is 0.05.
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { outletPoleSensorConfigurationEntry 9 }
|
|
|
|
outletPoleSensorTolerance OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The resolution: the difference between a sensor value and the actual value
|
|
The value of this OID variable should be scaled by
|
|
(outletPoleSensorDecimalDigits + 1). For example, if the value is 50 and
|
|
outletPoleSensorDecimalDigits is 2, then actual value is 0.05.
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { outletPoleSensorConfigurationEntry 10 }
|
|
|
|
outletPoleSensorMaximum OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The largest possible reading as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
outletPoleSensorDecimalDigits. For example, if the value is 1 and
|
|
outletPoleSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is clamped if the scaled maximum exceeds 4294967295. It
|
|
is undefined for sensors which can have negative readings.
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { outletPoleSensorConfigurationEntry 11 }
|
|
|
|
outletPoleSensorMinimum OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The smallest possible reading as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
outletPoleSensorDecimalDigits. For example, if the value is 1 and
|
|
outletPoleSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is undefined for sensors which can have negative readings.
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { outletPoleSensorConfigurationEntry 12 }
|
|
|
|
outletPoleSensorHysteresis OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The hysteresis used for deassertions
|
|
The value of this OID variable should be scaled by
|
|
outletPoleSensorDecimalDigits. For example, if the value is 1 and
|
|
outletPoleSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { outletPoleSensorConfigurationEntry 13 }
|
|
|
|
outletPoleSensorStateChangeDelay OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The delay measured in samples before a state is asserted.
|
|
If the value is zero, then the state is asserted as soon as
|
|
it is detected; if it is non-zero, say n, then the assertion
|
|
condition must exist for n+1 consecutive samples before the corresponding
|
|
assertion event is reported.
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { outletPoleSensorConfigurationEntry 14 }
|
|
|
|
outletPoleSensorLowerCriticalThreshold OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower critical threshold as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
outletPoleSensorDecimalDigits. For example, if the value is 1 and
|
|
outletPoleSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is clamped if the scaled threshold exceeds 4294967295. It
|
|
is undefined for sensors which can have negative readings.
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { outletPoleSensorConfigurationEntry 21 }
|
|
|
|
outletPoleSensorLowerWarningThreshold OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower warning threshold as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
outletPoleSensorDecimalDigits. For example, if the value is 1 and
|
|
outletPoleSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is clamped if the scaled threshold exceeds 4294967295. It
|
|
is undefined for sensors which can have negative readings.
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { outletPoleSensorConfigurationEntry 22 }
|
|
|
|
outletPoleSensorUpperCriticalThreshold OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper critical threshold as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
outletPoleSensorDecimalDigits. For example, if the value is 1 and
|
|
outletPoleSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is clamped if the scaled threshold exceeds 4294967295. It
|
|
is undefined for sensors which can have negative readings.
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { outletPoleSensorConfigurationEntry 23 }
|
|
|
|
outletPoleSensorUpperWarningThreshold OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper warning threshold as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
outletPoleSensorDecimalDigits. For example, if the value is 1 and
|
|
outletPoleSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is clamped if the scaled threshold exceeds 4294967295. It
|
|
is undefined for sensors which can have negative readings.
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { outletPoleSensorConfigurationEntry 24 }
|
|
|
|
outletPoleSensorEnabledThresholds OBJECT-TYPE
|
|
SYNTAX BITS{
|
|
lowerCritical(0),
|
|
lowerWarning(1),
|
|
upperWarning(2),
|
|
upperCritical(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A bit string which indicates which thresholds are enabled.
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { outletPoleSensorConfigurationEntry 25 }
|
|
|
|
outletPoleSensorSignedMaximum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The largest possible reading as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
outletPoleSensorDecimalDigits. For example, if the value is 1 and
|
|
outletPoleSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647).
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { outletPoleSensorConfigurationEntry 26 }
|
|
|
|
outletPoleSensorSignedMinimum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The smallest possible reading as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
outletPoleSensorDecimalDigits. For example, if the value is 1 and
|
|
outletPoleSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value determines whether to use the signed or unsigned threshold
|
|
and value columns: If the minimum is below zero the sensor can have
|
|
negative readings and the signed columns should be used.
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { outletPoleSensorConfigurationEntry 27 }
|
|
|
|
outletPoleSensorSignedLowerCriticalThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower critical threshold as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
outletPoleSensorDecimalDigits. For example, if the value is 1 and
|
|
outletPoleSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647).
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { outletPoleSensorConfigurationEntry 28 }
|
|
|
|
outletPoleSensorSignedLowerWarningThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower warning threshold as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
outletPoleSensorDecimalDigits. For example, if the value is 1 and
|
|
outletPoleSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647).
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { outletPoleSensorConfigurationEntry 29 }
|
|
|
|
outletPoleSensorSignedUpperCriticalThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper critical threshold as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
outletPoleSensorDecimalDigits. For example, if the value is 1 and
|
|
outletPoleSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647).
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { outletPoleSensorConfigurationEntry 30 }
|
|
|
|
outletPoleSensorSignedUpperWarningThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper warning threshold as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
outletPoleSensorDecimalDigits. For example, if the value is 1 and
|
|
outletPoleSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647).
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { outletPoleSensorConfigurationEntry 31 }
|
|
|
|
|
|
|
|
-- the externalSensorConfiguration table
|
|
|
|
-- The externalSensorConfiguration table contains information on the PDU's external Sensors.
|
|
|
|
|
|
|
|
externalSensorConfigurationTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ExternalSensorConfigurationEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of externalSensor configuration entries. The number of
|
|
entries is given by the value of externalSensorCount for the PDU."
|
|
::= { externalSensors 3 }
|
|
|
|
externalSensorConfigurationEntry OBJECT-TYPE
|
|
SYNTAX ExternalSensorConfigurationEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing parameters for an external sensor."
|
|
INDEX { pduId, sensorID }
|
|
::= { externalSensorConfigurationTable 1 }
|
|
|
|
ExternalSensorConfigurationEntryStruct ::= SEQUENCE {sensorID Integer32,
|
|
externalSensorType SensorTypeEnumeration,
|
|
externalSensorSerialNumber DisplayString,
|
|
externalSensorName DisplayString,
|
|
externalSensorDescription DisplayString,
|
|
externalSensorXCoordinate DisplayString,
|
|
externalSensorYCoordinate DisplayString,
|
|
externalSensorZCoordinate DisplayString,
|
|
externalSensorChannelNumber Integer32,
|
|
externalOnOffSensorSubtype SensorTypeEnumeration,
|
|
externalSensorLogAvailable TruthValue,
|
|
externalSensorUnits SensorUnitsEnumeration,
|
|
externalSensorDecimalDigits Unsigned32,
|
|
externalSensorAccuracy HundredthsOfAPercentage,
|
|
externalSensorResolution Unsigned32,
|
|
externalSensorTolerance Unsigned32,
|
|
externalSensorMaximum Integer32,
|
|
externalSensorMinimum Integer32,
|
|
externalSensorHysteresis Unsigned32,
|
|
externalSensorStateChangeDelay Unsigned32,
|
|
externalSensorLowerCriticalThreshold Integer32,
|
|
externalSensorLowerWarningThreshold Integer32,
|
|
externalSensorUpperCriticalThreshold Integer32,
|
|
externalSensorUpperWarningThreshold Integer32,
|
|
externalSensorEnabledThresholds BITS,
|
|
externalSensorIsActuator TruthValue,
|
|
externalSensorPosition DisplayString,
|
|
externalSensorUseDefaultThresholds TruthValue,
|
|
externalSensorAlarmedToNormalDelay Integer32
|
|
}
|
|
|
|
sensorID OBJECT-TYPE
|
|
SYNTAX Integer32(1..256)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value for each sensor. Its value
|
|
ranges between 1 and the value of externalSensorCount."
|
|
::= { externalSensorConfigurationEntry 1 }
|
|
|
|
|
|
externalSensorType OBJECT-TYPE
|
|
SYNTAX SensorTypeEnumeration
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of sensor."
|
|
::= { externalSensorConfigurationEntry 2 }
|
|
|
|
|
|
|
|
|
|
|
|
externalSensorSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sensor serial number."
|
|
::= { externalSensorConfigurationEntry 3 }
|
|
|
|
externalSensorName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The user-defined name."
|
|
::= { externalSensorConfigurationEntry 4 }
|
|
|
|
externalSensorDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The user-defined description."
|
|
::= { externalSensorConfigurationEntry 5 }
|
|
|
|
externalSensorXCoordinate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The X coordinate."
|
|
::= { externalSensorConfigurationEntry 6 }
|
|
|
|
externalSensorYCoordinate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Y coordinate."
|
|
::= { externalSensorConfigurationEntry 7 }
|
|
|
|
externalSensorZCoordinate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Z coordinate."
|
|
::= { externalSensorConfigurationEntry 8 }
|
|
|
|
|
|
externalSensorChannelNumber OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The channel number, applies only to contact sensors;
|
|
-1 for other sensors"
|
|
::= { externalSensorConfigurationEntry 9 }
|
|
|
|
externalOnOffSensorSubtype OBJECT-TYPE
|
|
SYNTAX SensorTypeEnumeration
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The subtype of the binary sensor"
|
|
::= { externalSensorConfigurationEntry 10 }
|
|
|
|
|
|
|
|
|
|
externalSensorLogAvailable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Is logging available for this sensor?"
|
|
::= { externalSensorConfigurationEntry 14 }
|
|
|
|
externalSensorUnits OBJECT-TYPE
|
|
SYNTAX SensorUnitsEnumeration
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The base units
|
|
This parameter does not apply
|
|
to onOff, trip, vibration, waterDetection,
|
|
smokeDetection sensors."
|
|
::= { externalSensorConfigurationEntry 16 }
|
|
|
|
externalSensorDecimalDigits OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of digits displayed to the right of the decimal point
|
|
This parameter does not apply
|
|
to onOff, trip, vibration, waterDetection,
|
|
smokeDetection sensors."
|
|
::= { externalSensorConfigurationEntry 17 }
|
|
|
|
|
|
|
|
|
|
externalSensorAccuracy OBJECT-TYPE
|
|
SYNTAX HundredthsOfAPercentage
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The accuracy: how close (in percent) the measurement is to the actual value
|
|
This parameter does not apply
|
|
to onOff, trip, vibration, waterDetection,
|
|
smokeDetection sensors."
|
|
::= { externalSensorConfigurationEntry 18 }
|
|
|
|
|
|
externalSensorResolution OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The resolution: the minimum difference between any two measured values
|
|
The value of this OID variable should be scaled by
|
|
externalSensorDecimalDigits. For example, if the value is 1 and
|
|
externalSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This parameter does not apply
|
|
to onOff, trip, vibration, waterDetection,
|
|
smokeDetection sensors."
|
|
::= { externalSensorConfigurationEntry 19 }
|
|
|
|
externalSensorTolerance OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The resolution: the difference between a sensor value and the actual value
|
|
The value of this OID variable should be scaled by
|
|
(externalSensorDecimalDigits + 1). For example, if the value is 50 and
|
|
externalSensorDecimalDigits is 2, then actual value is 0.05.
|
|
This parameter does not apply
|
|
to onOff, trip, vibration, waterDetection,
|
|
smokeDetection sensors."
|
|
::= { externalSensorConfigurationEntry 20 }
|
|
|
|
externalSensorMaximum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The largest possible value
|
|
The value of this OID variable should be scaled by
|
|
externalSensorDecimalDigits. For example, if the value is 1 and
|
|
externalSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This parameter does not apply
|
|
to onOff, trip, vibration, waterDetection,
|
|
smokeDetection sensors."
|
|
::= { externalSensorConfigurationEntry 21 }
|
|
|
|
externalSensorMinimum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The smallest possible value
|
|
The value of this OID variable should be scaled by
|
|
externalSensorDecimalDigits. For example, if the value is 1 and
|
|
externalSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This parameter does not apply
|
|
to onOff, trip, vibration, waterDetection,
|
|
smokeDetection sensors."
|
|
::= { externalSensorConfigurationEntry 22 }
|
|
|
|
|
|
|
|
externalSensorHysteresis OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The hysteresis used for deassertions
|
|
The value of this OID variable should be scaled by
|
|
externalSensorDecimalDigits. For example, if the value is 1 and
|
|
externalSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This parameter does not apply
|
|
to onOff, trip, vibration, waterDetection,
|
|
smokeDetection sensors."
|
|
::= { externalSensorConfigurationEntry 23 }
|
|
|
|
externalSensorStateChangeDelay OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The delay measured in samples before a state is asserted.
|
|
If the value is zero, then the state is asserted as soon as
|
|
it is detected; if it is non-zero, say n, then the assertion
|
|
condition must exist for n+1 consecutive samples before the corresponding
|
|
assertion event is reported.
|
|
At present, this value cannot be written (set)"
|
|
::= { externalSensorConfigurationEntry 24 }
|
|
|
|
externalSensorLowerCriticalThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower critical threshold
|
|
The value of this OID variable should be scaled by
|
|
externalSensorDecimalDigits. For example, if the value is 1 and
|
|
externalSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This parameter does not apply
|
|
to onOff, trip, vibration, waterDetection,
|
|
smokeDetection sensors."
|
|
::= { externalSensorConfigurationEntry 31 }
|
|
|
|
externalSensorLowerWarningThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower non-critical (warning) threshold
|
|
The value of this OID variable should be scaled by
|
|
externalSensorDecimalDigits. For example, if the value is 1 and
|
|
externalSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This parameter does not apply
|
|
to onOff, trip, vibration, waterDetection,
|
|
smokeDetection sensors."
|
|
::= { externalSensorConfigurationEntry 32 }
|
|
|
|
externalSensorUpperCriticalThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper critical threshold
|
|
The value of this OID variable should be scaled by
|
|
externalSensorDecimalDigits. For example, if the value is 1 and
|
|
externalSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This parameter does not apply
|
|
to onOff, trip, vibration, waterDetection,
|
|
smokeDetection sensors."
|
|
::= { externalSensorConfigurationEntry 33 }
|
|
|
|
externalSensorUpperWarningThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper non-critical (warning) threshold
|
|
The value of this OID variable should be scaled by
|
|
externalSensorDecimalDigits. For example, if the value is 1 and
|
|
externalSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This parameter does not apply
|
|
to onOff, trip, vibration, waterDetection,
|
|
smokeDetection sensors."
|
|
::= { externalSensorConfigurationEntry 34 }
|
|
|
|
|
|
externalSensorEnabledThresholds OBJECT-TYPE
|
|
SYNTAX BITS{
|
|
lowerCritical(0),
|
|
lowerWarning(1),
|
|
upperWarning(2),
|
|
upperCritical(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A bit string which indicates which thresholds are enabled.
|
|
This parameter does not apply
|
|
to onOff, trip, vibration, waterDetection,
|
|
smokeDetection sensors
|
|
"
|
|
::= { externalSensorConfigurationEntry 35}
|
|
|
|
|
|
externalSensorIsActuator OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Is this an actuator?
|
|
True: It is an actuator
|
|
False: It is not an actuator"
|
|
::= { externalSensorConfigurationEntry 36 }
|
|
|
|
|
|
externalSensorPosition OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The position of the sensor.
|
|
The format is a semicolon separated list of Keyword:value pairs - Keyword1:Value1;Keyword2:value2;...
|
|
Keyword can be one of the following: ONBOARD,DEVICE-1WIREPORT;HUBPORT,CHAIN-POSITION
|
|
Examples
|
|
1) Onboard Sensor
|
|
ONBOARD:CC1
|
|
2) Old sensor connected to device 1-wire port
|
|
DEVICE-1WIREPORT:2
|
|
3) Old sensor connected to hub port
|
|
DEVICE-1WIREPORT:2;HUBPORT:3
|
|
4) New style sensor connected to device 1-wire port
|
|
DEVICE-1WIREPORT:2;CHAIN-POSITION:3
|
|
5) Old style sensor connected to end of new style sensor chain
|
|
DEVICE-1WIREPORT:2;CHAIN-POSITION:7
|
|
"
|
|
::= { externalSensorConfigurationEntry 37 }
|
|
|
|
|
|
externalSensorUseDefaultThresholds OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Use default thresholds for this sensor?
|
|
True: Use Default thresholds for this sensor
|
|
|
|
False: Do not Use Default thresholds for this sensor"
|
|
::= { externalSensorConfigurationEntry 38 }
|
|
|
|
externalSensorAlarmedToNormalDelay OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The delay in seconds for transitions from the alarmed state to the normal state.
|
|
If the sensor type is motionDetection,
|
|
then it can set to a value greater >= 0
|
|
For all other sensor types,
|
|
the value is 0 and cannot be set to any other value.
|
|
"
|
|
::= { externalSensorConfigurationEntry 39 }
|
|
|
|
|
|
-- This table applies only to G1 External sensors.
|
|
-- This table is used for bulk configuration of G1 External sensors.
|
|
|
|
|
|
|
|
externalSensorTypeDefaultThresholdsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ExternalSensorTypeDefaultThresholdsEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of entries listing the default thresholds for each sensor type. "
|
|
::= { externalSensors 4 }
|
|
|
|
externalSensorTypeDefaultThresholdsEntry OBJECT-TYPE
|
|
SYNTAX ExternalSensorTypeDefaultThresholdsEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing default thresholds for a sensor type."
|
|
INDEX { pduId, sensorType }
|
|
::= { externalSensorTypeDefaultThresholdsTable 1 }
|
|
|
|
ExternalSensorTypeDefaultThresholdsEntryStruct ::= SEQUENCE {
|
|
externalSensorTypeDefaultHysteresis Unsigned32,
|
|
externalSensorTypeDefaultStateChangeDelay Unsigned32,
|
|
externalSensorTypeDefaultLowerCriticalThreshold Integer32,
|
|
externalSensorTypeDefaultLowerWarningThreshold Integer32,
|
|
externalSensorTypeDefaultUpperCriticalThreshold Integer32,
|
|
externalSensorTypeDefaultUpperWarningThreshold Integer32,
|
|
externalSensorTypeDefaultEnabledThresholds BITS
|
|
|
|
}
|
|
|
|
|
|
|
|
|
|
externalSensorTypeDefaultHysteresis OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The hysteresis used for deassertions
|
|
The value of this OID variable should be scaled by
|
|
externalSensorDecimalDigits. For example, if the value is 1 and
|
|
externalSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This parameter does not apply
|
|
to onOff, trip, vibration, waterDetection,
|
|
smokeDetection sensors."
|
|
::= { externalSensorTypeDefaultThresholdsEntry 3 }
|
|
|
|
externalSensorTypeDefaultStateChangeDelay OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The delay measured in samples before a state is asserted.
|
|
If the value is zero, then the state is asserted as soon as
|
|
it is detected; if it is non-zero, say n, then the assertion
|
|
condition must exist for n+1 consecutive samples before the corresponding
|
|
assertion event is reported.
|
|
At present, this value cannot be written (set)"
|
|
::= { externalSensorTypeDefaultThresholdsEntry 4 }
|
|
|
|
externalSensorTypeDefaultLowerCriticalThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower critical threshold
|
|
The value of this OID variable should be scaled by
|
|
externalSensorDecimalDigits. For example, if the value is 1 and
|
|
externalSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This parameter does not apply
|
|
to onOff, trip, vibration, waterDetection,
|
|
smokeDetection sensors."
|
|
::= { externalSensorTypeDefaultThresholdsEntry 5 }
|
|
|
|
|
|
|
|
externalSensorTypeDefaultLowerWarningThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower non-critical (warning) threshold
|
|
The value of this OID variable should be scaled by
|
|
externalSensorDecimalDigits. For example, if the value is 1 and
|
|
externalSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This parameter does not apply
|
|
to onOff, trip, vibration, waterDetection,
|
|
smokeDetection sensors."
|
|
::= { externalSensorTypeDefaultThresholdsEntry 6 }
|
|
|
|
|
|
externalSensorTypeDefaultUpperCriticalThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper critical threshold
|
|
The value of this OID variable should be scaled by
|
|
externalSensorDecimalDigits. For example, if the value is 1 and
|
|
externalSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This parameter does not apply
|
|
to onOff, trip, vibration, waterDetection,
|
|
smokeDetection sensors."
|
|
::= { externalSensorTypeDefaultThresholdsEntry 7 }
|
|
|
|
|
|
externalSensorTypeDefaultUpperWarningThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper non-critical (warning) threshold
|
|
The value of this OID variable should be scaled by
|
|
externalSensorDecimalDigits. For example, if the value is 1 and
|
|
externalSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This parameter does not apply
|
|
to onOff, trip, vibration, waterDetection,
|
|
smokeDetection sensors."
|
|
::= { externalSensorTypeDefaultThresholdsEntry 8 }
|
|
|
|
|
|
externalSensorTypeDefaultEnabledThresholds OBJECT-TYPE
|
|
SYNTAX BITS{
|
|
lowerCritical(0),
|
|
lowerWarning(1),
|
|
upperWarning(2),
|
|
upperCritical(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A bit string which indicates which thresholds are enabled.
|
|
This parameter does not apply
|
|
to onOff, trip, vibration, waterDetection,
|
|
smokeDetection sensors
|
|
"
|
|
::= { externalSensorTypeDefaultThresholdsEntry 9}
|
|
|
|
|
|
|
|
|
|
|
|
|
|
-- the server reachability table
|
|
|
|
-- The server Reachability table contains information on the ping feature.
|
|
|
|
|
|
|
|
|
|
serverReachabilityTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ServerReachabilityEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of server entries. The number of
|
|
entries is given by the value of serverCount for the PDU."
|
|
::= { serverReachability 3 }
|
|
|
|
serverReachabilityEntry OBJECT-TYPE
|
|
SYNTAX ServerReachabilityEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing parameters for a server."
|
|
INDEX { pduId, serverID }
|
|
::= { serverReachabilityTable 1 }
|
|
|
|
ServerReachabilityEntryStruct ::= SEQUENCE {serverID Integer32,
|
|
serverIPAddress DisplayString,
|
|
serverPingEnabled TruthValue
|
|
}
|
|
|
|
serverID OBJECT-TYPE
|
|
SYNTAX Integer32(1..256)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value for each server. Its value
|
|
ranges between 1 and the value of serverCount for that PDU"
|
|
::= { serverReachabilityEntry 1 }
|
|
|
|
|
|
|
|
|
|
|
|
serverIPAddress OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IP Address/host name of the server"
|
|
::= { serverReachabilityEntry 3 }
|
|
|
|
|
|
serverPingEnabled OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Is ping enabled for this server?"
|
|
::= { serverReachabilityEntry 4 }
|
|
|
|
|
|
-- the wireConfiguration table
|
|
|
|
-- The wireConfiguration table contains information on the PDU's wires.
|
|
|
|
|
|
wireConfigurationTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WireConfigurationEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"A list of wire configuration entries. The number of
|
|
entries is given by the value of wireCount for the PDU."
|
|
::= { wires 3 }
|
|
|
|
wireConfigurationEntry OBJECT-TYPE
|
|
SYNTAX WireConfigurationEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"An entry containing objects for a particular wire."
|
|
INDEX { pduId, wireId }
|
|
::= { wireConfigurationTable 1 }
|
|
|
|
WireConfigurationEntryStruct ::= SEQUENCE {
|
|
wireId Integer32,
|
|
wireLabel DisplayString,
|
|
wireCapabilities BITS,
|
|
wirePowerSource RowPointer
|
|
}
|
|
|
|
wireId OBJECT-TYPE
|
|
SYNTAX Integer32(1..256)
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"A unique value for each wire. Its value
|
|
ranges between 1 and the value of wireCount."
|
|
::= { wireConfigurationEntry 1 }
|
|
|
|
wireLabel OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The label on the PDU identifying the wire."
|
|
::= { wireConfigurationEntry 2 }
|
|
|
|
wireCapabilities OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
rmsCurrent(0),
|
|
peakCurrent(1),
|
|
unbalancedCurrent(2),
|
|
rmsVoltage(3),
|
|
activePower(4),
|
|
apparentPower(5),
|
|
powerFactor(6),
|
|
activeEnergy(7),
|
|
apparentEnergy(8)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"A bit string which indicates which wire sensors are available."
|
|
::= { wireConfigurationEntry 3 }
|
|
|
|
|
|
wirePowerSource OBJECT-TYPE
|
|
SYNTAX RowPointer
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This object allows discovery of how the PDU is wired. It indicates the
|
|
wire's power source which can one of the following:
|
|
overCurrentProtector
|
|
transfer switch
|
|
inlet
|
|
|
|
If the power source is an OverCurrentProtector, it
|
|
contains the OID of an overCurrentProtectorLabel in the
|
|
overCurrentProtectorConfiguration Table. The index of the OID can then be
|
|
used to reference other objects in the overCurrentProtectorConfigurationTable.
|
|
|
|
If the power source is an inlet, it contains the OID of
|
|
an inletLabel in the inletConfigurationTable. The index of the OID can
|
|
then be used to reference other objects in the inletConfigurationTable.
|
|
|
|
If the power source is a transferSwitch, it
|
|
contains the OID of a transferSwitchLabel in the
|
|
transferSwitchConfiguration Table. The index of the OID can then be
|
|
used to reference other objects in the transferSwitchConfigurationTable.
|
|
|
|
"
|
|
::= { wireConfigurationEntry 4}
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
-- The wireSensorConfiguration table contains information on the PDU's wire Sensors.
|
|
|
|
wireSensorConfigurationTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WireSensorConfigurationEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"A list of wireSensor configuration entries."
|
|
::= { wires 4 }
|
|
|
|
wireSensorConfigurationEntry OBJECT-TYPE
|
|
SYNTAX WireSensorConfigurationEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"An wireSensor entry containing objects for a
|
|
particular wire Sensor."
|
|
INDEX { pduId, wireId, sensorType }
|
|
::= { wireSensorConfigurationTable 1 }
|
|
|
|
WireSensorConfigurationEntryStruct ::= SEQUENCE {
|
|
wireSensorLogAvailable TruthValue,
|
|
wireSensorUnits SensorUnitsEnumeration,
|
|
wireSensorDecimalDigits Unsigned32,
|
|
wireSensorAccuracy HundredthsOfAPercentage,
|
|
wireSensorResolution Unsigned32,
|
|
wireSensorTolerance Unsigned32,
|
|
wireSensorMaximum Unsigned32,
|
|
wireSensorMinimum Unsigned32,
|
|
wireSensorHysteresis Unsigned32,
|
|
wireSensorStateChangeDelay Unsigned32,
|
|
wireSensorLowerCriticalThreshold Unsigned32,
|
|
wireSensorLowerWarningThreshold Unsigned32,
|
|
wireSensorUpperCriticalThreshold Unsigned32,
|
|
wireSensorUpperWarningThreshold Unsigned32,
|
|
wireSensorEnabledThresholds BITS
|
|
}
|
|
|
|
wireSensorLogAvailable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Is logging available for this sensor?"
|
|
::= { wireSensorConfigurationEntry 4 }
|
|
|
|
|
|
wireSensorUnits OBJECT-TYPE
|
|
SYNTAX SensorUnitsEnumeration
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The base units"
|
|
::= { wireSensorConfigurationEntry 6 }
|
|
|
|
wireSensorDecimalDigits OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The number of digits displayed to the right of the decimal point."
|
|
::= { wireSensorConfigurationEntry 7 }
|
|
|
|
wireSensorAccuracy OBJECT-TYPE
|
|
SYNTAX HundredthsOfAPercentage
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The accuracy: how close (in percent) the measurement is to the actual value"
|
|
::= { wireSensorConfigurationEntry 8 }
|
|
|
|
wireSensorResolution OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The resolution: the minimum difference between any two measured values
|
|
The value of this OID variable should be scaled by
|
|
wireSensorDecimalDigits. For example, if the value is 1 and
|
|
wireSensorDecimalDigits is 2, then actual value is 0.01."
|
|
::= { wireSensorConfigurationEntry 9 }
|
|
|
|
wireSensorTolerance OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The resolution: the difference between a sensor value and the actual value
|
|
The value of this OID variable should be scaled by
|
|
(wireSensorDecimalDigits + 1). For example, if the value is 50 and
|
|
wireSensorDecimalDigits is 2, then actual value is 0.05."
|
|
::= { wireSensorConfigurationEntry 10 }
|
|
|
|
wireSensorMaximum OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The largest possible value
|
|
The value of this OID variable should be scaled by
|
|
wireSensorDecimalDigits. For example, if the value is 1 and
|
|
wireSensorDecimalDigits is 2, then actual value is 0.01."
|
|
::= { wireSensorConfigurationEntry 11 }
|
|
|
|
wireSensorMinimum OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The smallest possible value
|
|
The value of this OID variable should be scaled by
|
|
wireSensorDecimalDigits. For example, if the value is 1 and
|
|
wireSensorDecimalDigits is 2, then actual value is 0.01."
|
|
::= { wireSensorConfigurationEntry 12 }
|
|
|
|
wireSensorHysteresis OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The hysteresis used for deassertions
|
|
The value of this OID variable should be scaled by
|
|
wireSensorDecimalDigits. For example, if the value is 1 and
|
|
wireSensorDecimalDigits is 2, then actual value is 0.01."
|
|
::= { wireSensorConfigurationEntry 13 }
|
|
|
|
wireSensorStateChangeDelay OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The delay measured in samples before a state is asserted.
|
|
If the value is zero, then the state is asserted as soon as
|
|
it is detected; if it is non-zero, say n, then the assertion
|
|
condition must exist for n+1 consecutive samples before the corresponding
|
|
assertion event is reported.
|
|
At present, this value cannot be written (set)"
|
|
::= { wireSensorConfigurationEntry 14 }
|
|
|
|
wireSensorLowerCriticalThreshold OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The lower critical threshold
|
|
The value of this OID variable should be scaled by
|
|
wireSensorDecimalDigits. For example, if the value is 1 and
|
|
wireSensorDecimalDigits is 2, then actual value is 0.01."
|
|
::= { wireSensorConfigurationEntry 21 }
|
|
|
|
wireSensorLowerWarningThreshold OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The lower non-critical (warning) threshold
|
|
The value of this OID variable should be scaled by
|
|
wireSensorDecimalDigits. For example, if the value is 1 and
|
|
wireSensorDecimalDigits is 2, then actual value is 0.01."
|
|
::= { wireSensorConfigurationEntry 22 }
|
|
|
|
wireSensorUpperCriticalThreshold OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The upper critical threshold
|
|
The value of this OID variable should be scaled by
|
|
wireSensorDecimalDigits. For example, if the value is 1 and
|
|
wireSensorDecimalDigits is 2, then actual value is 0.01."
|
|
::= { wireSensorConfigurationEntry 23 }
|
|
|
|
wireSensorUpperWarningThreshold OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The upper non-critical (warning) threshold
|
|
The value of this OID variable should be scaled by
|
|
wireSensorDecimalDigits. For example, if the value is 1 and
|
|
wireSensorDecimalDigits is 2, then actual value is 0.01."
|
|
::= { wireSensorConfigurationEntry 24 }
|
|
|
|
wireSensorEnabledThresholds OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
lowerCritical(0),
|
|
lowerWarning(1),
|
|
upperWarning(2),
|
|
upperCritical(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"A bit string which indicates which thresholds are enabled."
|
|
::= { wireSensorConfigurationEntry 25 }
|
|
|
|
|
|
|
|
|
|
-- the transferSwitchConfiguration table
|
|
|
|
-- The tsConfiguration table contains information on the TS ( Transfer Switch).
|
|
|
|
|
|
transferSwitchConfigurationTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TransferSwitchConfigurationEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of transfer switch configuration entries. The number of
|
|
entries is given by the value of transferSwitchCount."
|
|
::= { transferSwitch 3 }
|
|
|
|
transferSwitchConfigurationEntry OBJECT-TYPE
|
|
SYNTAX TransferSwitchConfigurationEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing objects for a particular transferSwitch."
|
|
INDEX { pduId, transferSwitchId }
|
|
::= { transferSwitchConfigurationTable 1 }
|
|
|
|
TransferSwitchConfigurationEntryStruct ::= SEQUENCE { transferSwitchId Integer32,
|
|
transferSwitchLabel DisplayString,
|
|
transferSwitchName DisplayString,
|
|
transferSwitchPreferredInlet Integer32,
|
|
transferSwitchAutoReTransferEnabled TruthValue,
|
|
transferSwitchAutoReTransferWaitTime Unsigned32,
|
|
transferSwitchAutoReTransferRequiresPhaseSync TruthValue,
|
|
transferSwitchFrontPanelManualTransferButtonEnabled TruthValue,
|
|
transferSwitchCapabilities BITS,
|
|
transferSwitchPowerSource1 RowPointer,
|
|
transferSwitchPowerSource2 RowPointer
|
|
}
|
|
|
|
|
|
transferSwitchId OBJECT-TYPE
|
|
SYNTAX Integer32(1..256)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value for each transfer switch. Its value
|
|
ranges between 1 and the value of transferSwitchCount."
|
|
::= { transferSwitchConfigurationEntry 1 }
|
|
|
|
transferSwitchLabel OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The label on the PDU identifying the TS."
|
|
::= { transferSwitchConfigurationEntry 2 }
|
|
|
|
transferSwitchName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The user-defined name of the transferSwitch."
|
|
::= { transferSwitchConfigurationEntry 3 }
|
|
|
|
transferSwitchPreferredInlet OBJECT-TYPE
|
|
SYNTAX Integer32(1..64)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The preferred Inlet. The TS powers the outlet from the preferred inlet when acceptable power
|
|
is available from the preferred inlet. "
|
|
::= { transferSwitchConfigurationEntry 4 }
|
|
|
|
|
|
transferSwitchAutoReTransferEnabled OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The TS can be configured to automatically retransfer back to the preferred inlet when power is restored.
|
|
Re-transfer only occurs if this variable is true."
|
|
::= { transferSwitchConfigurationEntry 20 }
|
|
|
|
|
|
transferSwitchAutoReTransferWaitTime OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Auto Re-Transfer Wait Time. Re-transfer occurs this many seconds after the condition causing the
|
|
original transfer has been corrected."
|
|
::= { transferSwitchConfigurationEntry 21 }
|
|
|
|
|
|
transferSwitchAutoReTransferRequiresPhaseSync OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If this parameter is False, then do not retransfer if there is a PHASE_SYNC_FAULT in effect. A
|
|
PHASE_SYNC_FAULT occurs when the phase difference between the inlets is too high."
|
|
::= { transferSwitchConfigurationEntry 22 }
|
|
|
|
|
|
transferSwitchFrontPanelManualTransferButtonEnabled OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If this parameter is false, then manual transfers caused by pressing the front panel switch are disabled. "
|
|
::= { transferSwitchConfigurationEntry 23 }
|
|
|
|
|
|
transferSwitchCapabilities OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
overloadStatus(32),
|
|
inletPhaseSyncAngle(37),
|
|
inletPhaseSync(38),
|
|
operatingState(39),
|
|
activeInlet(40),
|
|
switchStatus(47)
|
|
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A bit string which indicates which sensors are available for the transfer switch."
|
|
::= { transferSwitchConfigurationEntry 24 }
|
|
|
|
|
|
transferSwitchPowerSource1 OBJECT-TYPE
|
|
SYNTAX RowPointer
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object allows discovery of how the PDU is wired. It indicates the
|
|
transferSwitch's first power source which can one of the following:
|
|
overCurrentProtector
|
|
transfer switch
|
|
inlet
|
|
|
|
If the power source is an OverCurrentProtector, it
|
|
contains the OID of an overCurrentProtectorLabel in the
|
|
overCurrentProtectorConfiguration Table. The index of the OID can then be
|
|
used to reference other objects in the overCurrentProtectorConfigurationTable.
|
|
|
|
If the power source is an inlet, it contains the OID of
|
|
an inletLabel in the inletConfigurationTable. The index of the OID can
|
|
then be used to reference other objects in the inletConfigurationTable.
|
|
|
|
If the power source is a transferSwitch, it
|
|
contains the OID of a transferSwitchLabel in the
|
|
transferSwitchConfiguration Table. The index of the OID can then be
|
|
used to reference other objects in the transferSwitchConfigurationTable.
|
|
|
|
"
|
|
::= { transferSwitchConfigurationEntry 31 }
|
|
|
|
|
|
|
|
transferSwitchPowerSource2 OBJECT-TYPE
|
|
SYNTAX RowPointer
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object allows discovery of how the PDU is wired. It indicates the
|
|
transferSwitch's second power source which can one of the following:
|
|
overCurrentProtector
|
|
transfer switch
|
|
inlet
|
|
|
|
If the power source is an OverCurrentProtector, it
|
|
contains the OID of an overCurrentProtectorLabel in the
|
|
overCurrentProtectorConfiguration Table. The index of the OID can then be
|
|
used to reference other objects in the overCurrentProtectorConfigurationTable.
|
|
|
|
If the power source is an inlet, it contains the OID of
|
|
an inletLabel in the inletConfigurationTable. The index of the OID can
|
|
then be used to reference other objects in the inletConfigurationTable.
|
|
|
|
If the power source is a transferSwitch, it
|
|
contains the OID of a transferSwitchLabel in the
|
|
transferSwitchConfiguration Table. The index of the OID can then be
|
|
used to reference other objects in the transferSwitchConfigurationTable
|
|
|
|
"
|
|
::= { transferSwitchConfigurationEntry 32 }
|
|
|
|
|
|
|
|
|
|
|
|
-- The transfer switch sensor configuration table contains information on the transfer switch's sensors.
|
|
|
|
transferSwitchSensorConfigurationTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TransferSwitchSensorConfigurationEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of transfer switch sensor configuration entries. "
|
|
::= { transferSwitch 4 }
|
|
|
|
transferSwitchSensorConfigurationEntry OBJECT-TYPE
|
|
SYNTAX TransferSwitchSensorConfigurationEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing parameters for a transfer switch sensor."
|
|
INDEX { pduId, transferSwitchId, sensorType }
|
|
::= { transferSwitchSensorConfigurationTable 1 }
|
|
|
|
TransferSwitchSensorConfigurationEntryStruct ::= SEQUENCE {
|
|
transferSwitchSensorLogAvailable TruthValue,
|
|
transferSwitchSensorUnits SensorUnitsEnumeration,
|
|
transferSwitchSensorDecimalDigits Unsigned32,
|
|
transferSwitchSensorAccuracy HundredthsOfAPercentage,
|
|
transferSwitchSensorResolution Unsigned32,
|
|
transferSwitchSensorTolerance Unsigned32,
|
|
transferSwitchSensorMaximum Unsigned32,
|
|
transferSwitchSensorMinimum Unsigned32,
|
|
transferSwitchSensorHysteresis Unsigned32,
|
|
transferSwitchSensorStateChangeDelay Unsigned32,
|
|
transferSwitchSensorLowerCriticalThreshold Unsigned32,
|
|
transferSwitchSensorLowerWarningThreshold Unsigned32,
|
|
transferSwitchSensorUpperCriticalThreshold Unsigned32,
|
|
transferSwitchSensorUpperWarningThreshold Unsigned32,
|
|
transferSwitchSensorEnabledThresholds BITS,
|
|
transferSwitchSensorSignedMaximum Integer32,
|
|
transferSwitchSensorSignedMinimum Integer32,
|
|
transferSwitchSensorSignedLowerCriticalThreshold Integer32,
|
|
transferSwitchSensorSignedLowerWarningThreshold Integer32,
|
|
transferSwitchSensorSignedUpperCriticalThreshold Integer32,
|
|
transferSwitchSensorSignedUpperWarningThreshold Integer32
|
|
}
|
|
|
|
transferSwitchSensorLogAvailable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Is logging available for this sensor?"
|
|
::= { transferSwitchSensorConfigurationEntry 4 }
|
|
|
|
transferSwitchSensorUnits OBJECT-TYPE
|
|
SYNTAX SensorUnitsEnumeration
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The base units.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. operational state or switch fault sensors."
|
|
::= { transferSwitchSensorConfigurationEntry 6 }
|
|
|
|
transferSwitchSensorDecimalDigits OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of digits displayed to the right of the decimal point
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. operational state or switch fault sensors."
|
|
::= { transferSwitchSensorConfigurationEntry 7 }
|
|
|
|
transferSwitchSensorAccuracy OBJECT-TYPE
|
|
SYNTAX HundredthsOfAPercentage
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The accuracy: how close (in percent) the measurement is to the actual value
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. operational state or switch fault sensors."
|
|
::= { transferSwitchSensorConfigurationEntry 8 }
|
|
|
|
transferSwitchSensorResolution OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The resolution: the minimum difference between any two measured values
|
|
The value of this OID variable should be scaled by
|
|
transferSwitchSensorDecimalDigits. For example, if the value is 1 and
|
|
transferSwitchSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. operational state or switch fault sensors."
|
|
::= { transferSwitchSensorConfigurationEntry 9 }
|
|
|
|
transferSwitchSensorTolerance OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The resolution: the difference between a sensor value and the actual value
|
|
The value of this OID variable should be scaled by
|
|
(transferSwitchSensorDecimalDigits + 1). For example, if the value is 50 and
|
|
transferSwitchSensorDecimalDigits is 2, then actual value is 0.05.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. operational state or switch fault sensors."
|
|
::= { transferSwitchSensorConfigurationEntry 10 }
|
|
|
|
transferSwitchSensorMaximum OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The largest possible reading as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
transferSwitchSensorDecimalDigits. For example, if the value is 1 and
|
|
transferSwitchSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is clamped if the scaled maximum exceeds 4294967295. It
|
|
is undefined for sensors which can have negative readings.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. operational state or switch fault sensors."
|
|
::= { transferSwitchSensorConfigurationEntry 11 }
|
|
|
|
transferSwitchSensorMinimum OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The smallest possible reading as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
transferSwitchSensorDecimalDigits. For example, if the value is 1 and
|
|
transferSwitchSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is undefined for sensors which can have negative readings.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. operational state or switch fault sensors."
|
|
::= { transferSwitchSensorConfigurationEntry 12 }
|
|
|
|
transferSwitchSensorHysteresis OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The hysteresis used for deassertions
|
|
The value of this OID variable should be scaled by
|
|
transferSwitchSensorDecimalDigits. For example, if the value is 1 and
|
|
transferSwitchSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. operational state or switch fault sensors."
|
|
::= { transferSwitchSensorConfigurationEntry 13 }
|
|
|
|
transferSwitchSensorStateChangeDelay OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The delay measured in samples before a state is asserted.
|
|
If the value is zero, then the state is asserted as soon as
|
|
it is detected; if it is non-zero, say n, then the assertion
|
|
condition must exist for n+1 consecutive samples before the corresponding
|
|
assertion event is reported.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. operational state or switch fault sensors."
|
|
::= { transferSwitchSensorConfigurationEntry 14 }
|
|
|
|
transferSwitchSensorLowerCriticalThreshold OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower critical threshold as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
transferSwitchSensorDecimalDigits. For example, if the value is 1 and
|
|
transferSwitchSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is clamped if the scaled threshold exceeds 4294967295. It
|
|
is undefined for sensors which can have negative readings.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. operational state or switch fault sensors."
|
|
::= { transferSwitchSensorConfigurationEntry 21 }
|
|
|
|
transferSwitchSensorLowerWarningThreshold OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower warning threshold as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
transferSwitchSensorDecimalDigits. For example, if the value is 1 and
|
|
transferSwitchSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is clamped if the scaled threshold exceeds 4294967295. It
|
|
is undefined for sensors which can have negative readings.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. operational state or switch fault sensors."
|
|
::= { transferSwitchSensorConfigurationEntry 22 }
|
|
|
|
transferSwitchSensorUpperCriticalThreshold OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper critical threshold as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
transferSwitchSensorDecimalDigits. For example, if the value is 1 and
|
|
transferSwitchSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is clamped if the scaled threshold exceeds 4294967295. It
|
|
is undefined for sensors which can have negative readings.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. operational state or switch fault sensors."
|
|
::= { transferSwitchSensorConfigurationEntry 23 }
|
|
|
|
transferSwitchSensorUpperWarningThreshold OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper warning threshold as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
transferSwitchSensorDecimalDigits. For example, if the value is 1 and
|
|
transferSwitchSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is clamped if the scaled threshold exceeds 4294967295. It
|
|
is undefined for sensors which can have negative readings.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. operational state or switch fault sensors."
|
|
::= { transferSwitchSensorConfigurationEntry 24 }
|
|
|
|
transferSwitchSensorEnabledThresholds OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
lowerCritical(0),
|
|
lowerWarning(1),
|
|
upperWarning(2),
|
|
upperCritical(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A bit string which indicates which thresholds are enabled.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. operational state or switch fault sensors."
|
|
::= { transferSwitchSensorConfigurationEntry 25 }
|
|
|
|
transferSwitchSensorSignedMaximum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The largest possible reading as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
transferSwitchSensorDecimalDigits. For example, if the value is 1 and
|
|
transferSwitchSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647).
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. operational state or switch fault sensors."
|
|
::= { transferSwitchSensorConfigurationEntry 26 }
|
|
|
|
transferSwitchSensorSignedMinimum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The smallest possible reading as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
transferSwitchSensorDecimalDigits. For example, if the value is 1 and
|
|
transferSwitchSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value determines whether to use the signed or unsigned threshold
|
|
and value columns: If the minimum is below zero the sensor can have
|
|
negative readings and the signed columns should be used.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. operational state or switch fault sensors."
|
|
::= { transferSwitchSensorConfigurationEntry 27 }
|
|
|
|
transferSwitchSensorSignedLowerCriticalThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower critical threshold as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
transferSwitchSensorDecimalDigits. For example, if the value is 1 and
|
|
transferSwitchSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647).
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. operational state or switch fault sensors."
|
|
::= { transferSwitchSensorConfigurationEntry 28 }
|
|
|
|
transferSwitchSensorSignedLowerWarningThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower warning threshold as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
transferSwitchSensorDecimalDigits. For example, if the value is 1 and
|
|
transferSwitchSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647).
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. operational state or switch fault sensors."
|
|
::= { transferSwitchSensorConfigurationEntry 29 }
|
|
|
|
transferSwitchSensorSignedUpperCriticalThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper critical threshold as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
transferSwitchSensorDecimalDigits. For example, if the value is 1 and
|
|
transferSwitchSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647).
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. operational state or switch fault sensors."
|
|
::= { transferSwitchSensorConfigurationEntry 30 }
|
|
|
|
transferSwitchSensorSignedUpperWarningThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper warning threshold as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
transferSwitchSensorDecimalDigits. For example, if the value is 1 and
|
|
transferSwitchSensorDecimalDigits is 2, then actual value is 0.01.
|
|
The value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647).
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. operational state or switch fault sensors."
|
|
::= { transferSwitchSensorConfigurationEntry 31 }
|
|
|
|
|
|
|
|
-- The PeripheralDevicePackageTable table contains information on the peripheral Device Packages connected to the PDU
|
|
|
|
|
|
peripheralDevicePackageTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PeripheralDevicePackageEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of entries for the peripheral Device Packages connected to each PDU. The number of
|
|
entries is given by the value of peripheralDevicePackagesCount."
|
|
::= { externalSensors 5}
|
|
|
|
peripheralDevicePackageEntry OBJECT-TYPE
|
|
SYNTAX PeripheralDevicePackageEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing objects for a controller."
|
|
INDEX { pduId, peripheralDevicePackageId }
|
|
::= { peripheralDevicePackageTable 1 }
|
|
|
|
PeripheralDevicePackageEntryStruct ::= SEQUENCE {
|
|
peripheralDevicePackageId Integer32,
|
|
peripheralDevicePackageSerialNumber DisplayString,
|
|
peripheralDevicePackageModel DisplayString,
|
|
peripheralDevicePackageFirmwareVersion DisplayString,
|
|
peripheralDevicePackageMinFirmwareVersion DisplayString,
|
|
peripheralDevicePackageFirmwareTimeStamp Unsigned32,
|
|
peripheralDevicePackagePosition DisplayString,
|
|
peripheralDevicePackageState DisplayString
|
|
}
|
|
|
|
|
|
|
|
|
|
|
|
peripheralDevicePackageId OBJECT-TYPE
|
|
SYNTAX Integer32(1..256)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value for each peripheral device package."
|
|
::= { peripheralDevicePackageEntry 1 }
|
|
|
|
|
|
peripheralDevicePackageSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The peripheral device package serial number."
|
|
::= { peripheralDevicePackageEntry 3 }
|
|
|
|
peripheralDevicePackageModel OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The peripheral device package model.
|
|
Examples are DX-D2C6, DPX2-T1, DPX2-T1H1, DPX2-T2H1, DPX2-T3H1"
|
|
::= { peripheralDevicePackageEntry 4 }
|
|
|
|
|
|
|
|
peripheralDevicePackageFirmwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The peripheral device package firmware version."
|
|
::= { peripheralDevicePackageEntry 5 }
|
|
|
|
|
|
peripheralDevicePackageMinFirmwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The peripheral device package minimum firmware version.
|
|
This field may be empty. If it is not empty, then it shall not be possible
|
|
to downgrade the peripheral device firmware to a
|
|
version < minimum firmware version number."
|
|
::= { peripheralDevicePackageEntry 6 }
|
|
|
|
|
|
peripheralDevicePackageFirmwareTimeStamp OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time when the peripheralDevicePackage firmware was updated in UNIX(epoch)time.
|
|
It is measured in seconds relative to January 1, 1970 (midnight UTC/GMT),
|
|
i.e a value of 0 indicates January 1, 1970 (midnight UTC/GMT)."
|
|
::= { peripheralDevicePackageEntry 7 }
|
|
|
|
peripheralDevicePackagePosition OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The position of the package.
|
|
The format is a semicolon separated list of Keyword:value pairs -
|
|
Keyword1:Value1;Keyword2:value2;...
|
|
Keyword can be one of the following:
|
|
ONBOARD,DEVICE-1WIREPORT;HUBPORT,CHAIN-POSITION
|
|
Examples
|
|
1) Onboard Sensor
|
|
ONBOARD:CC1
|
|
2) Old sensor connected to device 1-wire port
|
|
DEVICE-1WIREPORT:2
|
|
3) Old sensor connected to hub port
|
|
DEVICE-1WIREPORT:2;HUBPORT:3
|
|
4) New style sensor connected to device 1-wire port
|
|
DEVICE-1WIREPORT:2;CHAIN-POSITION:3
|
|
5) Old style sensor connected to end of new style sensor chain
|
|
DEVICE-1WIREPORT:2;CHAIN-POSITION:7
|
|
"
|
|
::= { peripheralDevicePackageEntry 8 }
|
|
|
|
peripheralDevicePackageState OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The state of the package."
|
|
::= { peripheralDevicePackageEntry 9 }
|
|
|
|
|
|
-- the log table
|
|
|
|
-- The logIndexTable
|
|
|
|
logIndexTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF LogIndexEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of log entries."
|
|
::= { logUnit 1 }
|
|
|
|
logIndexEntry OBJECT-TYPE
|
|
SYNTAX LogIndexEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the log containing sensor data."
|
|
INDEX { pduId }
|
|
::= { logIndexTable 1 }
|
|
|
|
LogIndexEntryStruct ::= SEQUENCE {
|
|
oldestLogID Integer32,
|
|
newestLogID Integer32
|
|
}
|
|
|
|
|
|
|
|
|
|
oldestLogID OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index of the oldest data in the buffer for this PDU."
|
|
::= { logIndexEntry 2 }
|
|
|
|
newestLogID OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index of the newest data in the buffer for this PDU."
|
|
::= { logIndexEntry 3 }
|
|
|
|
|
|
|
|
-- The logTimeStampTable
|
|
|
|
logTimeStampTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF LogTimeStampEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of entries containing the timestamps of the entries in the log."
|
|
::= { logUnit 2 }
|
|
|
|
logTimeStampEntry OBJECT-TYPE
|
|
SYNTAX LogTimeStampEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing the timestamp for log entries."
|
|
INDEX { pduId, logIndex }
|
|
::= { logTimeStampTable 1 }
|
|
|
|
LogTimeStampEntryStruct ::= SEQUENCE {logIndex Integer32,
|
|
logTimeStamp Unsigned32
|
|
}
|
|
|
|
logIndex OBJECT-TYPE
|
|
SYNTAX Integer32(1..256)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value for each entry in the log. Its value
|
|
ranges between 1 and the value of logSize."
|
|
::= { logTimeStampEntry 1 }
|
|
|
|
|
|
logTimeStamp OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time when the data was collected. It is measured in seconds relative to
|
|
January 1, 1970 (midnight UTC/GMT), i.e a value of 0 indicates
|
|
January 1, 1970 (midnight UTC/GMT)."
|
|
::= { logTimeStampEntry 2 }
|
|
|
|
|
|
|
|
|
|
-- The unitSensorLogTable
|
|
|
|
unitSensorLogTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UnitSensorLogEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of unit sensor entries in the log."
|
|
::= { logUnit 3 }
|
|
|
|
unitSensorLogEntry OBJECT-TYPE
|
|
SYNTAX UnitSensorLogEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing log objects for an unit sensor."
|
|
INDEX { pduId, sensorType, logIndex }
|
|
::= { unitSensorLogTable 1 }
|
|
|
|
UnitSensorLogEntryStruct ::= SEQUENCE {
|
|
logUnitSensorDataAvailable TruthValue,
|
|
logUnitSensorState SensorStateEnumeration,
|
|
logUnitSensorAvgValue Unsigned32,
|
|
logUnitSensorMaxValue Unsigned32,
|
|
logUnitSensorMinValue Unsigned32,
|
|
logUnitSensorSignedAvgValue Integer32,
|
|
logUnitSensorSignedMaxValue Integer32,
|
|
logUnitSensorSignedMinValue Integer32
|
|
}
|
|
|
|
logUnitSensorDataAvailable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Is data available for this sensor during this measurement period?"
|
|
::= { unitSensorLogEntry 2 }
|
|
|
|
logUnitSensorState OBJECT-TYPE
|
|
SYNTAX SensorStateEnumeration
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sensor state."
|
|
::= { unitSensorLogEntry 3 }
|
|
|
|
logUnitSensorAvgValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The average sensor reading for the log period as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
unitSensorDecimalDigits. For example, if the value is 1 and
|
|
unitSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value will wrap around if the scaled sensor reading exceeds
|
|
4294967295. It is undefined for sensors which can have negative
|
|
readings."
|
|
::= { unitSensorLogEntry 4 }
|
|
|
|
logUnitSensorMaxValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum sensor reading for the log period as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
unitSensorDecimalDigits. For example, if the value is 1 and
|
|
unitSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value will wrap around if the scaled sensor reading exceeds
|
|
4294967295. It is undefined for sensors which can have negative
|
|
readings."
|
|
::= { unitSensorLogEntry 5 }
|
|
|
|
logUnitSensorMinValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The minimum sensor reading for the log period as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
unitSensorDecimalDigits. For example, if the value is 1 and
|
|
unitSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value will wrap around if the scaled sensor reading exceeds
|
|
4294967295. It is undefined for sensors which can have negative
|
|
readings."
|
|
::= { unitSensorLogEntry 6 }
|
|
|
|
logUnitSensorSignedAvgValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The average sensor reading for the log period as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
unitSensorDecimalDigits. For example, if the value is 1 and
|
|
unitSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647)."
|
|
::= { unitSensorLogEntry 7 }
|
|
|
|
logUnitSensorSignedMaxValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum sensor reading for the log period as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
unitSensorDecimalDigits. For example, if the value is 1 and
|
|
unitSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647)."
|
|
::= { unitSensorLogEntry 8 }
|
|
|
|
logUnitSensorSignedMinValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The minimum sensor reading for the log period as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
unitSensorDecimalDigits. For example, if the value is 1 and
|
|
unitSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647)."
|
|
::= { unitSensorLogEntry 9 }
|
|
|
|
|
|
|
|
-- The inletSensorLogTable
|
|
|
|
|
|
|
|
inletSensorLogTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF InletSensorLogEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of inlet sensor entries. The number of
|
|
entries is given by the value of inletCount for the PDU."
|
|
::= { logInlet 3 }
|
|
|
|
inletSensorLogEntry OBJECT-TYPE
|
|
SYNTAX InletSensorLogEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing log objects for an inlet sensor."
|
|
INDEX { pduId, inletId, sensorType, logIndex }
|
|
::= { inletSensorLogTable 1 }
|
|
|
|
InletSensorLogEntryStruct ::= SEQUENCE {
|
|
logInletSensorDataAvailable TruthValue,
|
|
logInletSensorState SensorStateEnumeration,
|
|
logInletSensorAvgValue Unsigned32,
|
|
logInletSensorMaxValue Unsigned32,
|
|
logInletSensorMinValue Unsigned32,
|
|
logInletSensorSignedAvgValue Integer32,
|
|
logInletSensorSignedMaxValue Integer32,
|
|
logInletSensorSignedMinValue Integer32
|
|
}
|
|
|
|
logInletSensorDataAvailable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Is data available for this sensor during this measurement period?"
|
|
::= { inletSensorLogEntry 2 }
|
|
|
|
logInletSensorState OBJECT-TYPE
|
|
SYNTAX SensorStateEnumeration
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sensor state."
|
|
::= { inletSensorLogEntry 3 }
|
|
|
|
logInletSensorAvgValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The average sensor reading for the log period as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
inletSensorDecimalDigits. For example, if the value is 1 and
|
|
inletSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value will wrap around if the scaled sensor reading exceeds
|
|
4294967295. It is undefined for sensors which can have negative
|
|
readings."
|
|
::= { inletSensorLogEntry 4 }
|
|
|
|
logInletSensorMaxValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum sensor reading for the log period as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
inletSensorDecimalDigits. For example, if the value is 1 and
|
|
inletSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value will wrap around if the scaled sensor reading exceeds
|
|
4294967295. It is undefined for sensors which can have negative
|
|
readings."
|
|
::= { inletSensorLogEntry 5 }
|
|
|
|
logInletSensorMinValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The minimum sensor reading for the log period as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
inletSensorDecimalDigits. For example, if the value is 1 and
|
|
inletSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value will wrap around if the scaled sensor reading exceeds
|
|
4294967295. It is undefined for sensors which can have negative
|
|
readings."
|
|
::= { inletSensorLogEntry 6 }
|
|
|
|
logInletSensorSignedAvgValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The average sensor reading for the log period as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
inletSensorDecimalDigits. For example, if the value is 1 and
|
|
inletSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647)."
|
|
::= { inletSensorLogEntry 7 }
|
|
|
|
logInletSensorSignedMaxValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum sensor reading for the log period as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
inletSensorDecimalDigits. For example, if the value is 1 and
|
|
inletSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647)."
|
|
::= { inletSensorLogEntry 8 }
|
|
|
|
logInletSensorSignedMinValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The minimum sensor reading for the log period as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
inletSensorDecimalDigits. For example, if the value is 1 and
|
|
inletSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647)."
|
|
::= { inletSensorLogEntry 9 }
|
|
|
|
|
|
-- The inletPoleSensorLogTable
|
|
|
|
inletPoleSensorLogTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF InletPoleSensorLogEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of inletPole sensor entries. The number of
|
|
entries is given by the value of inletPoleCount for the inlet."
|
|
::= { logInlet 4 }
|
|
|
|
inletPoleSensorLogEntry OBJECT-TYPE
|
|
SYNTAX InletPoleSensorLogEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing log objects for an inletPole sensor."
|
|
INDEX { pduId,inletId, inletPoleIndex,sensorType,logIndex }
|
|
::= { inletPoleSensorLogTable 1 }
|
|
|
|
InletPoleSensorLogEntryStruct ::= SEQUENCE {
|
|
logInletPoleSensorDataAvailable TruthValue,
|
|
logInletPoleSensorState SensorStateEnumeration,
|
|
logInletPoleSensorAvgValue Unsigned32,
|
|
logInletPoleSensorMaxValue Unsigned32,
|
|
logInletPoleSensorMinValue Unsigned32,
|
|
logInletPoleSensorSignedAvgValue Integer32,
|
|
logInletPoleSensorSignedMaxValue Integer32,
|
|
logInletPoleSensorSignedMinValue Integer32
|
|
}
|
|
|
|
logInletPoleSensorDataAvailable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Is data available for this sensor during this measurement period?"
|
|
::= { inletPoleSensorLogEntry 2 }
|
|
|
|
|
|
logInletPoleSensorState OBJECT-TYPE
|
|
SYNTAX SensorStateEnumeration
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sensor state."
|
|
::= { inletPoleSensorLogEntry 3 }
|
|
|
|
logInletPoleSensorAvgValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The average sensor reading for the log period as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
inletPoleSensorDecimalDigits. For example, if the value is 1 and
|
|
inletPoleSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value will wrap around if the scaled sensor reading exceeds
|
|
4294967295. It is undefined for sensors which can have negative
|
|
readings."
|
|
::= { inletPoleSensorLogEntry 4 }
|
|
|
|
logInletPoleSensorMaxValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum sensor reading for the log period as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
inletPoleSensorDecimalDigits. For example, if the value is 1 and
|
|
inletPoleSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value will wrap around if the scaled sensor reading exceeds
|
|
4294967295. It is undefined for sensors which can have negative
|
|
readings."
|
|
::= { inletPoleSensorLogEntry 5 }
|
|
|
|
logInletPoleSensorMinValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The minimum sensor reading for the log period as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
inletPoleSensorDecimalDigits. For example, if the value is 1 and
|
|
inletPoleSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value will wrap around if the scaled sensor reading exceeds
|
|
4294967295. It is undefined for sensors which can have negative
|
|
readings."
|
|
::= { inletPoleSensorLogEntry 6 }
|
|
|
|
logInletPoleSensorSignedAvgValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The average sensor reading for the log period as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
inletPoleSensorDecimalDigits. For example, if the value is 1 and
|
|
inletPoleSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647)."
|
|
::= { inletPoleSensorLogEntry 7 }
|
|
|
|
logInletPoleSensorSignedMaxValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum sensor reading for the log period as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
inletPoleSensorDecimalDigits. For example, if the value is 1 and
|
|
inletPoleSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647)."
|
|
::= { inletPoleSensorLogEntry 8 }
|
|
|
|
logInletPoleSensorSignedMinValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The minimum sensor reading for the log period as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
inletPoleSensorDecimalDigits. For example, if the value is 1 and
|
|
inletPoleSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647)."
|
|
::= { inletPoleSensorLogEntry 9 }
|
|
|
|
|
|
|
|
-- The outletSensorLogTable
|
|
|
|
outletSensorLogTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OutletSensorLogEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of outlet sensor entries. The number of
|
|
entries is given by the value of outletCount for the PDU."
|
|
::= { logOutlet 3 }
|
|
|
|
outletSensorLogEntry OBJECT-TYPE
|
|
SYNTAX OutletSensorLogEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing log objects for an outlet sensor."
|
|
INDEX { pduId, outletId, sensorType,logIndex }
|
|
::= { outletSensorLogTable 1 }
|
|
|
|
OutletSensorLogEntryStruct ::= SEQUENCE {
|
|
logOutletSensorDataAvailable TruthValue,
|
|
logOutletSensorState SensorStateEnumeration,
|
|
logOutletSensorAvgValue Unsigned32,
|
|
logOutletSensorMaxValue Unsigned32,
|
|
logOutletSensorMinValue Unsigned32,
|
|
logOutletSensorSignedAvgValue Integer32,
|
|
logOutletSensorSignedMaxValue Integer32,
|
|
logOutletSensorSignedMinValue Integer32
|
|
}
|
|
|
|
logOutletSensorDataAvailable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Is data available for this sensor during this measurement period?"
|
|
::= { outletSensorLogEntry 2 }
|
|
|
|
logOutletSensorState OBJECT-TYPE
|
|
SYNTAX SensorStateEnumeration
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sensor state."
|
|
::= { outletSensorLogEntry 3 }
|
|
|
|
logOutletSensorAvgValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The average sensor reading for the log period as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
outletSensorDecimalDigits. For example, if the value is 1 and
|
|
outletSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value will wrap around if the scaled sensor reading exceeds
|
|
4294967295. It is undefined for sensors which can have negative
|
|
readings."
|
|
::= { outletSensorLogEntry 4 }
|
|
|
|
logOutletSensorMaxValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum sensor reading for the log period as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
outletSensorDecimalDigits. For example, if the value is 1 and
|
|
outletSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value will wrap around if the scaled sensor reading exceeds
|
|
4294967295. It is undefined for sensors which can have negative
|
|
readings."
|
|
::= { outletSensorLogEntry 5 }
|
|
|
|
logOutletSensorMinValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The minimum sensor reading for the log period as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
outletSensorDecimalDigits. For example, if the value is 1 and
|
|
outletSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value will wrap around if the scaled sensor reading exceeds
|
|
4294967295. It is undefined for sensors which can have negative
|
|
readings."
|
|
::= { outletSensorLogEntry 6 }
|
|
|
|
logOutletSensorSignedAvgValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The average sensor reading for the log period as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
outletSensorDecimalDigits. For example, if the value is 1 and
|
|
outletSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647)."
|
|
::= { outletSensorLogEntry 7 }
|
|
|
|
logOutletSensorSignedMaxValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum sensor reading for the log period as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
outletSensorDecimalDigits. For example, if the value is 1 and
|
|
outletSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647)."
|
|
::= { outletSensorLogEntry 8 }
|
|
|
|
logOutletSensorSignedMinValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The minimum sensor reading for the log period as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
outletSensorDecimalDigits. For example, if the value is 1 and
|
|
outletSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647)."
|
|
::= { outletSensorLogEntry 9 }
|
|
|
|
|
|
|
|
-- The outletPoleSensorLogTable
|
|
|
|
outletPoleSensorLogTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OutletPoleSensorLogEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of outletPole sensor entries. The number of
|
|
entries is given by the value of outletPoleCount for the outlet."
|
|
::= { logOutlet 4 }
|
|
|
|
outletPoleSensorLogEntry OBJECT-TYPE
|
|
SYNTAX OutletPoleSensorLogEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing log objects for an outletPole sensor."
|
|
INDEX { pduId, outletId, outletPoleIndex,sensorType,logIndex }
|
|
::= { outletPoleSensorLogTable 1 }
|
|
|
|
OutletPoleSensorLogEntryStruct ::= SEQUENCE {
|
|
logOutletPoleSensorDataAvailable TruthValue,
|
|
logOutletPoleSensorState SensorStateEnumeration,
|
|
logOutletPoleSensorAvgValue Unsigned32,
|
|
logOutletPoleSensorMaxValue Unsigned32,
|
|
logOutletPoleSensorMinValue Unsigned32,
|
|
logOutletPoleSensorSignedAvgValue Integer32,
|
|
logOutletPoleSensorSignedMaxValue Integer32,
|
|
logOutletPoleSensorSignedMinValue Integer32
|
|
}
|
|
|
|
logOutletPoleSensorDataAvailable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Is data available for this sensor during this measurement period?"
|
|
::= { outletPoleSensorLogEntry 2 }
|
|
|
|
logOutletPoleSensorState OBJECT-TYPE
|
|
SYNTAX SensorStateEnumeration
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sensor state."
|
|
::= { outletPoleSensorLogEntry 3 }
|
|
|
|
logOutletPoleSensorAvgValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The average sensor reading for the log period as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
outletPoleSensorDecimalDigits. For example, if the value is 1 and
|
|
outletPoleSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value will wrap around if the scaled sensor reading exceeds
|
|
4294967295. It is undefined for sensors which can have negative
|
|
readings."
|
|
::= { outletPoleSensorLogEntry 4 }
|
|
|
|
logOutletPoleSensorMaxValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum sensor reading for the log period as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
outletPoleSensorDecimalDigits. For example, if the value is 1 and
|
|
outletPoleSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value will wrap around if the scaled sensor reading exceeds
|
|
4294967295. It is undefined for sensors which can have negative
|
|
readings."
|
|
::= { outletPoleSensorLogEntry 5 }
|
|
|
|
logOutletPoleSensorMinValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The minimum sensor reading for the log period as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
outletPoleSensorDecimalDigits. For example, if the value is 1 and
|
|
outletPoleSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value will wrap around if the scaled sensor reading exceeds
|
|
4294967295. It is undefined for sensors which can have negative
|
|
readings."
|
|
::= { outletPoleSensorLogEntry 6 }
|
|
|
|
logOutletPoleSensorSignedAvgValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The average sensor reading for the log period as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
outletPoleSensorDecimalDigits. For example, if the value is 1 and
|
|
outletPoleSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647)."
|
|
::= { outletPoleSensorLogEntry 7 }
|
|
|
|
logOutletPoleSensorSignedMaxValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum sensor reading for the log period as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
outletPoleSensorDecimalDigits. For example, if the value is 1 and
|
|
outletPoleSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647)."
|
|
::= { outletPoleSensorLogEntry 8 }
|
|
|
|
logOutletPoleSensorSignedMinValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The minimum sensor reading for the log period as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
outletPoleSensorDecimalDigits. For example, if the value is 1 and
|
|
outletPoleSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647)."
|
|
::= { outletPoleSensorLogEntry 9 }
|
|
|
|
|
|
|
|
-- The overCurrentProtectorSensorLogTable
|
|
|
|
overCurrentProtectorSensorLogTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OverCurrentProtectorSensorLogEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of overCurrentProtector sensor entries. The number of
|
|
entries is given by the value of overCurrentProtectorCount for the PDU."
|
|
::= { logOverCurrentProtector 3 }
|
|
|
|
overCurrentProtectorSensorLogEntry OBJECT-TYPE
|
|
SYNTAX OverCurrentProtectorSensorLogEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing log objects for an overCurrentProtector sensor."
|
|
INDEX { pduId, overCurrentProtectorIndex, sensorType, logIndex }
|
|
::= { overCurrentProtectorSensorLogTable 1 }
|
|
|
|
OverCurrentProtectorSensorLogEntryStruct ::= SEQUENCE {
|
|
logOverCurrentProtectorSensorDataAvailable TruthValue,
|
|
logOverCurrentProtectorSensorState SensorStateEnumeration,
|
|
logOverCurrentProtectorSensorAvgValue Unsigned32,
|
|
logOverCurrentProtectorSensorMaxValue Unsigned32,
|
|
logOverCurrentProtectorSensorMinValue Unsigned32,
|
|
logOverCurrentProtectorSensorSignedAvgValue Integer32,
|
|
logOverCurrentProtectorSensorSignedMaxValue Integer32,
|
|
logOverCurrentProtectorSensorSignedMinValue Integer32
|
|
}
|
|
|
|
logOverCurrentProtectorSensorDataAvailable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Is data available for this sensor during this measurement period?"
|
|
::= { overCurrentProtectorSensorLogEntry 2 }
|
|
|
|
logOverCurrentProtectorSensorState OBJECT-TYPE
|
|
SYNTAX SensorStateEnumeration
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sensor state."
|
|
::= { overCurrentProtectorSensorLogEntry 3 }
|
|
|
|
logOverCurrentProtectorSensorAvgValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The average sensor reading for the log period as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and
|
|
overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value will wrap around if the scaled sensor reading exceeds
|
|
4294967295. It is undefined for sensors which can have negative
|
|
readings."
|
|
::= { overCurrentProtectorSensorLogEntry 4 }
|
|
|
|
logOverCurrentProtectorSensorMaxValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum sensor reading for the log period as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and
|
|
overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value will wrap around if the scaled sensor reading exceeds
|
|
4294967295. It is undefined for sensors which can have negative
|
|
readings."
|
|
::= { overCurrentProtectorSensorLogEntry 5 }
|
|
|
|
logOverCurrentProtectorSensorMinValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The minimum sensor reading for the log period as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and
|
|
overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value will wrap around if the scaled sensor reading exceeds
|
|
4294967295. It is undefined for sensors which can have negative
|
|
readings."
|
|
::= { overCurrentProtectorSensorLogEntry 6 }
|
|
|
|
logOverCurrentProtectorSensorSignedAvgValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The average sensor reading for the log period as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and
|
|
overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647)."
|
|
::= { overCurrentProtectorSensorLogEntry 7 }
|
|
|
|
logOverCurrentProtectorSensorSignedMaxValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum sensor reading for the log period as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and
|
|
overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647)."
|
|
::= { overCurrentProtectorSensorLogEntry 8 }
|
|
|
|
logOverCurrentProtectorSensorSignedMinValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The minimum sensor reading for the log period as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and
|
|
overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647)."
|
|
::= { overCurrentProtectorSensorLogEntry 9 }
|
|
|
|
|
|
|
|
-- The externalSensorLogTable
|
|
|
|
externalSensorLogTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ExternalSensorLogEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of external sensor entries. The number of
|
|
entries is given by the value of externalSensorCount for the PDU."
|
|
::= { logExternalSensor 3 }
|
|
|
|
externalSensorLogEntry OBJECT-TYPE
|
|
SYNTAX ExternalSensorLogEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing log objects for an external sensor."
|
|
INDEX { pduId, sensorID, logIndex }
|
|
::= { externalSensorLogTable 1 }
|
|
|
|
ExternalSensorLogEntryStruct ::= SEQUENCE {
|
|
logExternalSensorDataAvailable TruthValue,
|
|
logExternalSensorState SensorStateEnumeration,
|
|
logExternalSensorAvgValue Integer32,
|
|
logExternalSensorMaxValue Integer32,
|
|
logExternalSensorMinValue Integer32
|
|
}
|
|
|
|
logExternalSensorDataAvailable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Is data available for this sensor during this measurement period?"
|
|
::= { externalSensorLogEntry 2 }
|
|
|
|
logExternalSensorState OBJECT-TYPE
|
|
SYNTAX SensorStateEnumeration
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sensor state."
|
|
::= { externalSensorLogEntry 3 }
|
|
|
|
logExternalSensorAvgValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sensor reading average value.
|
|
The value of this OID variable should be scaled by
|
|
externalSensorDecimalDigits. For example, if the value is 1 and
|
|
externalSensorDecimalDigits is 2, then actual value is 0.01."
|
|
::= { externalSensorLogEntry 4 }
|
|
|
|
logExternalSensorMaxValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sensor reading maximum value.
|
|
The value of this OID variable should be scaled by
|
|
externalSensorDecimalDigits. For example, if the value is 1 and
|
|
externalSensorDecimalDigits is 2, then actual value is 0.01."
|
|
::= { externalSensorLogEntry 5 }
|
|
|
|
logExternalSensorMinValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sensor reading minimum value.
|
|
The value of this OID variable should be scaled by
|
|
externalSensorDecimalDigits. For example, if the value is 1 and
|
|
externalSensorDecimalDigits is 2, then actual value is 0.01."
|
|
::= { externalSensorLogEntry 6 }
|
|
|
|
|
|
-- The wireSensorLogTable
|
|
|
|
wireSensorLogTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WireSensorLogEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"A list of wire sensor entries. The number of
|
|
entries is given by the value of wireCount for the PDU."
|
|
::= { logWire 3 }
|
|
|
|
wireSensorLogEntry OBJECT-TYPE
|
|
SYNTAX WireSensorLogEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"An entry containing log objects for a wire sensor."
|
|
INDEX { pduId, wireId, sensorType, logIndex }
|
|
::= { wireSensorLogTable 1 }
|
|
|
|
WireSensorLogEntryStruct ::= SEQUENCE {
|
|
logWireSensorDataAvailable TruthValue,
|
|
logWireSensorState SensorStateEnumeration,
|
|
logWireSensorAvgValue Unsigned32,
|
|
logWireSensorMaxValue Unsigned32,
|
|
logWireSensorMinValue Unsigned32
|
|
}
|
|
|
|
logWireSensorDataAvailable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Is data available for this sensor during this measurement period?"
|
|
::= { wireSensorLogEntry 2 }
|
|
|
|
logWireSensorState OBJECT-TYPE
|
|
SYNTAX SensorStateEnumeration
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The sensor state."
|
|
::= { wireSensorLogEntry 3 }
|
|
|
|
logWireSensorAvgValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The sensor reading average value.
|
|
The value of this OID variable should be scaled by
|
|
wireSensorDecimalDigits. For example, if the value is 1 and
|
|
wireSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value will wrap around if the value exceeds 4294967295"
|
|
::= { wireSensorLogEntry 4 }
|
|
|
|
logWireSensorMaxValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The sensor reading maximum value.
|
|
The value of this OID variable should be scaled by
|
|
wireSensorDecimalDigits. For example, if the value is 1 and
|
|
wireSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value will wrap around if the value exceeds 4294967295"
|
|
::= { wireSensorLogEntry 5 }
|
|
|
|
logWireSensorMinValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The sensor reading minimum value.
|
|
The value of this OID variable should be scaled by
|
|
wireSensorDecimalDigits. For example, if the value is 1 and
|
|
wireSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value will wrap around if the value exceeds 4294967295."
|
|
::= { wireSensorLogEntry 6 }
|
|
|
|
|
|
|
|
|
|
|
|
|
|
-- The transferSwitchSensorLogTable
|
|
|
|
transferSwitchSensorLogTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TransferSwitchSensorLogEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of Transfer Switch sensor entries. The number of
|
|
entries is given by the value of transferSwitchCount for the PDU."
|
|
::= { logTransferSwitch 3 }
|
|
|
|
transferSwitchSensorLogEntry OBJECT-TYPE
|
|
SYNTAX TransferSwitchSensorLogEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing log objects for a transfer switch sensor."
|
|
INDEX { pduId, transferSwitchId, sensorType, logIndex }
|
|
::= { transferSwitchSensorLogTable 1 }
|
|
|
|
TransferSwitchSensorLogEntryStruct ::= SEQUENCE {
|
|
logTransferSwitchSensorDataAvailable TruthValue,
|
|
logTransferSwitchSensorState SensorStateEnumeration,
|
|
logTransferSwitchSensorAvgValue Unsigned32,
|
|
logTransferSwitchSensorMaxValue Unsigned32,
|
|
logTransferSwitchSensorMinValue Unsigned32,
|
|
logTransferSwitchSensorSignedAvgValue Integer32,
|
|
logTransferSwitchSensorSignedMaxValue Integer32,
|
|
logTransferSwitchSensorSignedMinValue Integer32
|
|
}
|
|
|
|
logTransferSwitchSensorDataAvailable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Is data available for this sensor during this measurement period?"
|
|
::= { transferSwitchSensorLogEntry 2 }
|
|
|
|
logTransferSwitchSensorState OBJECT-TYPE
|
|
SYNTAX SensorStateEnumeration
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sensor state."
|
|
::= { transferSwitchSensorLogEntry 3 }
|
|
|
|
logTransferSwitchSensorAvgValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The average sensor reading for the log period as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
transferSwitchSensorDecimalDigits. For example, if the value is 1 and
|
|
transferSwitchSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value will wrap around if the scaled sensor reading exceeds
|
|
4294967295. It is undefined for sensors which can have negative
|
|
readings."
|
|
::= { transferSwitchSensorLogEntry 4 }
|
|
|
|
logTransferSwitchSensorMaxValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum sensor reading for the log period as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
transferSwitchSensorDecimalDigits. For example, if the value is 1 and
|
|
transferSwitchSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value will wrap around if the scaled sensor reading exceeds
|
|
4294967295. It is undefined for sensors which can have negative
|
|
readings."
|
|
::= { transferSwitchSensorLogEntry 5 }
|
|
|
|
logTransferSwitchSensorMinValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The minimum sensor reading for the log period as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
transferSwitchSensorDecimalDigits. For example, if the value is 1 and
|
|
transferSwitchSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value will wrap around if the scaled sensor reading exceeds
|
|
4294967295. It is undefined for sensors which can have negative
|
|
readings."
|
|
::= { transferSwitchSensorLogEntry 6 }
|
|
|
|
logTransferSwitchSensorSignedAvgValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The average sensor reading for the log period as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
transferSwitchSensorDecimalDigits. For example, if the value is 1 and
|
|
transferSwitchSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647)."
|
|
::= { transferSwitchSensorLogEntry 7 }
|
|
|
|
logTransferSwitchSensorSignedMaxValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum sensor reading for the log period as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
transferSwitchSensorDecimalDigits. For example, if the value is 1 and
|
|
transferSwitchSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647)."
|
|
::= { transferSwitchSensorLogEntry 8 }
|
|
|
|
logTransferSwitchSensorSignedMinValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The minimum sensor reading for the log period as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
transferSwitchSensorDecimalDigits. For example, if the value is 1 and
|
|
transferSwitchSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647)."
|
|
::= { transferSwitchSensorLogEntry 9 }
|
|
|
|
|
|
|
|
-- the Measurements table
|
|
|
|
|
|
|
|
-- The unitSensorMeasurementsTable
|
|
|
|
unitSensorMeasurementsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UnitSensorMeasurementsEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of unit sensor entries."
|
|
::= { measurementsUnit 3 }
|
|
|
|
unitSensorMeasurementsEntry OBJECT-TYPE
|
|
SYNTAX UnitSensorMeasurementsEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing measurement objects for an unit sensor."
|
|
INDEX { pduId, sensorType }
|
|
::= { unitSensorMeasurementsTable 1 }
|
|
|
|
UnitSensorMeasurementsEntryStruct ::= SEQUENCE {
|
|
measurementsUnitSensorIsAvailable TruthValue,
|
|
measurementsUnitSensorState SensorStateEnumeration,
|
|
measurementsUnitSensorValue Unsigned32,
|
|
measurementsUnitSensorTimeStamp Unsigned32,
|
|
measurementsUnitSensorSignedValue Integer32
|
|
}
|
|
|
|
|
|
|
|
measurementsUnitSensorIsAvailable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Is the sensor available?"
|
|
::= { unitSensorMeasurementsEntry 2 }
|
|
|
|
|
|
|
|
measurementsUnitSensorState OBJECT-TYPE
|
|
SYNTAX SensorStateEnumeration
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sensor state."
|
|
::= { unitSensorMeasurementsEntry 3 }
|
|
|
|
measurementsUnitSensorValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sensor reading as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
unitSensorDecimalDigits. For example, if the value is 1 and
|
|
unitSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value will wrap around if the scaled sensor reading exceeds
|
|
4294967295. It is undefined for sensors which can have negative
|
|
readings.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. power supply status sensors."
|
|
::= { unitSensorMeasurementsEntry 4 }
|
|
|
|
measurementsUnitSensorTimeStamp OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The timestamp."
|
|
::= { unitSensorMeasurementsEntry 5 }
|
|
|
|
measurementsUnitSensorSignedValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sensor reading as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
unitSensorDecimalDigits. For example, if the value is 1 and
|
|
unitSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647).
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. power supply status sensors."
|
|
::= { unitSensorMeasurementsEntry 6 }
|
|
|
|
|
|
|
|
-- The inletSensorMeasurementsTable
|
|
|
|
inletSensorMeasurementsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF InletSensorMeasurementsEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of inlet sensor entries. The number of
|
|
entries is given by the value of inletCount for the PDU."
|
|
::= { measurementsInlet 3 }
|
|
|
|
inletSensorMeasurementsEntry OBJECT-TYPE
|
|
SYNTAX InletSensorMeasurementsEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing measurement objects for an inlet sensor."
|
|
INDEX { pduId, inletId, sensorType }
|
|
::= { inletSensorMeasurementsTable 1 }
|
|
|
|
InletSensorMeasurementsEntryStruct ::= SEQUENCE {
|
|
measurementsInletSensorIsAvailable TruthValue,
|
|
measurementsInletSensorState SensorStateEnumeration,
|
|
measurementsInletSensorValue Unsigned32,
|
|
measurementsInletSensorTimeStamp Unsigned32,
|
|
measurementsInletSensorSignedValue Integer32
|
|
}
|
|
|
|
measurementsInletSensorIsAvailable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Is the sensor available?"
|
|
::= { inletSensorMeasurementsEntry 2 }
|
|
|
|
|
|
measurementsInletSensorState OBJECT-TYPE
|
|
SYNTAX SensorStateEnumeration
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sensor state."
|
|
::= { inletSensorMeasurementsEntry 3 }
|
|
|
|
measurementsInletSensorValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sensor reading as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
inletSensorDecimalDigits. For example, if the value is 1 and
|
|
inletSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value will wrap around if the scaled sensor reading exceeds
|
|
4294967295. It is undefined for sensors which can have negative
|
|
readings.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. surge protector status sensors."
|
|
::= { inletSensorMeasurementsEntry 4 }
|
|
|
|
measurementsInletSensorTimeStamp OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The timestamp."
|
|
::= { inletSensorMeasurementsEntry 5 }
|
|
|
|
measurementsInletSensorSignedValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sensor reading as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
inletSensorDecimalDigits. For example, if the value is 1 and
|
|
inletSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647).
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. surge protector status sensors."
|
|
::= { inletSensorMeasurementsEntry 6 }
|
|
|
|
|
|
|
|
-- The inletPoleSensorMeasurementsTable
|
|
|
|
inletPoleSensorMeasurementsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF InletPoleSensorMeasurementsEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of inletPole sensor entries. The number of
|
|
entries is given by the value of inletPoleCount for the inlet."
|
|
::= { measurementsInlet 4 }
|
|
|
|
inletPoleSensorMeasurementsEntry OBJECT-TYPE
|
|
SYNTAX InletPoleSensorMeasurementsEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing measurement objects for an inletPole sensor."
|
|
INDEX { pduId, inletId, inletPoleIndex,sensorType }
|
|
::= { inletPoleSensorMeasurementsTable 1 }
|
|
|
|
InletPoleSensorMeasurementsEntryStruct ::= SEQUENCE {
|
|
measurementsInletPoleSensorIsAvailable TruthValue,
|
|
measurementsInletPoleSensorState SensorStateEnumeration,
|
|
measurementsInletPoleSensorValue Unsigned32,
|
|
measurementsInletPoleSensorTimeStamp Unsigned32,
|
|
measurementsInletPoleSensorSignedValue Integer32
|
|
}
|
|
|
|
|
|
measurementsInletPoleSensorIsAvailable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Is the sensor available?"
|
|
::= { inletPoleSensorMeasurementsEntry 2 }
|
|
|
|
measurementsInletPoleSensorState OBJECT-TYPE
|
|
SYNTAX SensorStateEnumeration
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sensor state."
|
|
::= { inletPoleSensorMeasurementsEntry 3 }
|
|
|
|
measurementsInletPoleSensorValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sensor reading as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
inletPoleSensorDecimalDigits. For example, if the value is 1 and
|
|
inletPoleSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value will wrap around if the scaled sensor reading exceeds
|
|
4294967295. It is undefined for sensors which can have negative
|
|
readings.
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { inletPoleSensorMeasurementsEntry 4 }
|
|
|
|
measurementsInletPoleSensorTimeStamp OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The timestamp."
|
|
::= { inletPoleSensorMeasurementsEntry 5 }
|
|
|
|
measurementsInletPoleSensorSignedValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sensor reading as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
inletPoleSensorDecimalDigits. For example, if the value is 1 and
|
|
inletPoleSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647).
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { inletPoleSensorMeasurementsEntry 6 }
|
|
|
|
|
|
|
|
-- The outletSensorMeasurementsTable
|
|
|
|
outletSensorMeasurementsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OutletSensorMeasurementsEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of outlet sensor entries. The number of
|
|
entries is given by the value of outletCount for the PDU."
|
|
::= { measurementsOutlet 3 }
|
|
|
|
outletSensorMeasurementsEntry OBJECT-TYPE
|
|
SYNTAX OutletSensorMeasurementsEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing measurement objects for an outlet sensor."
|
|
INDEX { pduId, outletId, sensorType }
|
|
::= { outletSensorMeasurementsTable 1 }
|
|
|
|
OutletSensorMeasurementsEntryStruct ::= SEQUENCE {
|
|
measurementsOutletSensorIsAvailable TruthValue,
|
|
measurementsOutletSensorState SensorStateEnumeration,
|
|
measurementsOutletSensorValue Unsigned32,
|
|
measurementsOutletSensorTimeStamp Unsigned32,
|
|
measurementsOutletSensorSignedValue Integer32
|
|
}
|
|
|
|
measurementsOutletSensorIsAvailable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Is the sensor available?"
|
|
::= { outletSensorMeasurementsEntry 2 }
|
|
|
|
measurementsOutletSensorState OBJECT-TYPE
|
|
SYNTAX SensorStateEnumeration
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sensor state."
|
|
::= { outletSensorMeasurementsEntry 3 }
|
|
|
|
measurementsOutletSensorValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sensor reading as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
outletSensorDecimalDigits. For example, if the value is 1 and
|
|
outletSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value will wrap around if the scaled sensor reading exceeds
|
|
4294967295. It is undefined for sensors which can have negative
|
|
readings.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. outlet state sensors."
|
|
::= { outletSensorMeasurementsEntry 4 }
|
|
|
|
measurementsOutletSensorTimeStamp OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The timestamp."
|
|
::= { outletSensorMeasurementsEntry 5 }
|
|
|
|
measurementsOutletSensorSignedValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sensor reading as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
outletSensorDecimalDigits. For example, if the value is 1 and
|
|
outletSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647).
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. outlet state sensors."
|
|
::= { outletSensorMeasurementsEntry 6 }
|
|
|
|
|
|
|
|
-- The outletPoleSensorMeasurementsTable
|
|
|
|
outletPoleSensorMeasurementsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OutletPoleSensorMeasurementsEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of outletPole sensor entries. The number of
|
|
entries is given by the value of outletPoletCount for the outlet."
|
|
::= { measurementsOutlet 4 }
|
|
|
|
outletPoleSensorMeasurementsEntry OBJECT-TYPE
|
|
SYNTAX OutletPoleSensorMeasurementsEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing measurement objects for an outletPole sensor."
|
|
INDEX { pduId, outletId, outletPoleIndex,sensorType }
|
|
::= { outletPoleSensorMeasurementsTable 1 }
|
|
|
|
OutletPoleSensorMeasurementsEntryStruct ::= SEQUENCE {
|
|
measurementsOutletPoleSensorIsAvailable TruthValue,
|
|
measurementsOutletPoleSensorState SensorStateEnumeration,
|
|
measurementsOutletPoleSensorValue Unsigned32,
|
|
measurementsOutletPoleSensorTimeStamp Unsigned32,
|
|
measurementsOutletPoleSensorSignedValue Integer32
|
|
}
|
|
|
|
measurementsOutletPoleSensorIsAvailable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Is the sensor available?"
|
|
::= { outletPoleSensorMeasurementsEntry 2 }
|
|
|
|
measurementsOutletPoleSensorState OBJECT-TYPE
|
|
SYNTAX SensorStateEnumeration
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sensor state."
|
|
::= { outletPoleSensorMeasurementsEntry 3 }
|
|
|
|
measurementsOutletPoleSensorValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sensor reading as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
outletPoleSensorDecimalDigits. For example, if the value is 50 and
|
|
outletPoleSensorDecimalDigits is 2, then actual value is 0.05.
|
|
This value will wrap around if the scaled sensor reading exceeds
|
|
4294967295. It is undefined for sensors which can have negative
|
|
readings.
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { outletPoleSensorMeasurementsEntry 4 }
|
|
|
|
measurementsOutletPoleSensorTimeStamp OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The timestamp."
|
|
::= { outletPoleSensorMeasurementsEntry 5 }
|
|
|
|
measurementsOutletPoleSensorSignedValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sensor reading as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
outletPoleSensorDecimalDigits. For example, if the value is 50 and
|
|
outletPoleSensorDecimalDigits is 2, then actual value is 0.05.
|
|
This value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647).
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { outletPoleSensorMeasurementsEntry 6 }
|
|
|
|
|
|
|
|
-- The overCurrentProtectorSensorMeasurementsTable
|
|
|
|
overCurrentProtectorSensorMeasurementsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OverCurrentProtectorSensorMeasurementsEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of overCurrentProtector sensor entries. The number of
|
|
entries is given by the value of overCurrentProtectorCount for the PDU."
|
|
::= { measurementsOverCurrentProtector 3 }
|
|
|
|
overCurrentProtectorSensorMeasurementsEntry OBJECT-TYPE
|
|
SYNTAX OverCurrentProtectorSensorMeasurementsEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing measurement objects for an overCurrentProtector."
|
|
INDEX { pduId, overCurrentProtectorIndex, sensorType }
|
|
::= { overCurrentProtectorSensorMeasurementsTable 1 }
|
|
|
|
OverCurrentProtectorSensorMeasurementsEntryStruct ::= SEQUENCE {
|
|
measurementsOverCurrentProtectorSensorIsAvailable TruthValue,
|
|
measurementsOverCurrentProtectorSensorState SensorStateEnumeration,
|
|
measurementsOverCurrentProtectorSensorValue Unsigned32,
|
|
measurementsOverCurrentProtectorSensorTimeStamp Unsigned32,
|
|
measurementsOverCurrentProtectorSensorSignedValue Integer32
|
|
}
|
|
|
|
|
|
measurementsOverCurrentProtectorSensorIsAvailable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Is the sensor available?"
|
|
::= { overCurrentProtectorSensorMeasurementsEntry 2 }
|
|
|
|
measurementsOverCurrentProtectorSensorState OBJECT-TYPE
|
|
SYNTAX SensorStateEnumeration
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sensor state."
|
|
::= { overCurrentProtectorSensorMeasurementsEntry 3 }
|
|
|
|
measurementsOverCurrentProtectorSensorValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sensor reading as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and
|
|
overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value will wrap around if the scaled sensor reading exceeds
|
|
4294967295. It is undefined for sensors which can have negative
|
|
readings.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. trip sensors."
|
|
::= { overCurrentProtectorSensorMeasurementsEntry 4 }
|
|
|
|
measurementsOverCurrentProtectorSensorTimeStamp OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The timestamp."
|
|
::= { overCurrentProtectorSensorMeasurementsEntry 5 }
|
|
|
|
measurementsOverCurrentProtectorSensorSignedValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sensor reading as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and
|
|
overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647).
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. trip sensors."
|
|
::= { overCurrentProtectorSensorMeasurementsEntry 6 }
|
|
|
|
|
|
|
|
-- The externalSensorMeasurementsTable
|
|
|
|
externalSensorMeasurementsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ExternalSensorMeasurementsEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of external sensor entries. The number of
|
|
entries is given by the value of externalSensorCount for the PDU."
|
|
::= { measurementsExternalSensor 3 }
|
|
|
|
externalSensorMeasurementsEntry OBJECT-TYPE
|
|
SYNTAX ExternalSensorMeasurementsEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing measurement objects for an external sensor."
|
|
INDEX { pduId, sensorID }
|
|
::= { externalSensorMeasurementsTable 1 }
|
|
|
|
ExternalSensorMeasurementsEntryStruct ::= SEQUENCE {
|
|
measurementsExternalSensorIsAvailable TruthValue,
|
|
measurementsExternalSensorState SensorStateEnumeration,
|
|
measurementsExternalSensorValue Integer32,
|
|
measurementsExternalSensorTimeStamp Unsigned32
|
|
}
|
|
|
|
|
|
measurementsExternalSensorIsAvailable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Is the sensor available?"
|
|
::= { externalSensorMeasurementsEntry 2 }
|
|
|
|
|
|
measurementsExternalSensorState OBJECT-TYPE
|
|
SYNTAX SensorStateEnumeration
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sensor state."
|
|
::= { externalSensorMeasurementsEntry 3 }
|
|
|
|
measurementsExternalSensorValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sensor reading as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
externalSensorDecimalDigits. For example, if the value is 1 and
|
|
externalSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. contact closure or smoke detection sensors."
|
|
::= { externalSensorMeasurementsEntry 4 }
|
|
|
|
measurementsExternalSensorTimeStamp OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sensor reading timestamp."
|
|
::= { externalSensorMeasurementsEntry 5 }
|
|
|
|
|
|
|
|
-- The wireSensorMeasurementsTable
|
|
|
|
wireSensorMeasurementsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WireSensorMeasurementsEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"A list of wire sensor entries. The number of
|
|
entries is given by the value of wireCount for the PDU."
|
|
::= { measurementsWire 3 }
|
|
|
|
wireSensorMeasurementsEntry OBJECT-TYPE
|
|
SYNTAX WireSensorMeasurementsEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"An entry containing measurement objects for a wire."
|
|
INDEX { pduId, wireId, sensorType }
|
|
::= { wireSensorMeasurementsTable 1 }
|
|
|
|
WireSensorMeasurementsEntryStruct ::= SEQUENCE {
|
|
measurementsWireSensorIsAvailable TruthValue,
|
|
measurementsWireSensorState SensorStateEnumeration,
|
|
measurementsWireSensorValue Unsigned32,
|
|
measurementsWireSensorTimeStamp Unsigned32
|
|
}
|
|
|
|
measurementsWireSensorIsAvailable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Is the sensor available?"
|
|
::= { wireSensorMeasurementsEntry 2 }
|
|
|
|
measurementsWireSensorState OBJECT-TYPE
|
|
SYNTAX SensorStateEnumeration
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The sensor state."
|
|
::= { wireSensorMeasurementsEntry 3 }
|
|
|
|
measurementsWireSensorValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The sensor value.
|
|
The value of this OID variable should be scaled by
|
|
wireSensorDecimalDigits. For example, if the value is 1 and
|
|
wireSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value will wrap around if the value exceeds 4294967295
|
|
This parameter does not apply to sensors without numerical reading."
|
|
::= { wireSensorMeasurementsEntry 4 }
|
|
|
|
measurementsWireSensorTimeStamp OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The timestamp."
|
|
::= { wireSensorMeasurementsEntry 5 }
|
|
|
|
|
|
|
|
|
|
|
|
|
|
-- The transfer switch SensorMeasurementsTable
|
|
|
|
transferSwitchSensorMeasurementsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TransferSwitchSensorMeasurementsEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of transfer switch sensor entries. The number of
|
|
entries is given by the value of transferSwitchCount for the PDU."
|
|
::= { measurementsTransferSwitch 3 }
|
|
|
|
transferSwitchSensorMeasurementsEntry OBJECT-TYPE
|
|
SYNTAX TransferSwitchSensorMeasurementsEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing measurement objects for a transfer switch."
|
|
INDEX { pduId, transferSwitchId, sensorType }
|
|
::= { transferSwitchSensorMeasurementsTable 1 }
|
|
|
|
TransferSwitchSensorMeasurementsEntryStruct ::= SEQUENCE {
|
|
measurementsTransferSwitchSensorIsAvailable TruthValue,
|
|
measurementsTransferSwitchSensorState SensorStateEnumeration,
|
|
measurementsTransferSwitchSensorValue Unsigned32,
|
|
measurementsTransferSwitchSensorTimeStamp Unsigned32,
|
|
measurementsTransferSwitchSensorSignedValue Integer32
|
|
}
|
|
|
|
measurementsTransferSwitchSensorIsAvailable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Is the sensor available?"
|
|
::= { transferSwitchSensorMeasurementsEntry 2 }
|
|
|
|
measurementsTransferSwitchSensorState OBJECT-TYPE
|
|
SYNTAX SensorStateEnumeration
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sensor state."
|
|
::= { transferSwitchSensorMeasurementsEntry 3 }
|
|
|
|
measurementsTransferSwitchSensorValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sensor reading as an unsigned integer.
|
|
The value of this OID variable should be scaled by
|
|
transferSwitchSensorDecimalDigits. For example, if the value is 1 and
|
|
transferSwitchSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value will wrap around if the scaled sensor reading exceeds
|
|
4294967295. It is undefined for sensors which can have negative
|
|
readings.
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. operational state or switch fault sensors."
|
|
::= { transferSwitchSensorMeasurementsEntry 4 }
|
|
|
|
measurementsTransferSwitchSensorTimeStamp OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The timestamp."
|
|
::= { transferSwitchSensorMeasurementsEntry 5 }
|
|
|
|
measurementsTransferSwitchSensorSignedValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sensor reading as a signed integer.
|
|
The value of this OID variable should be scaled by
|
|
transferSwitchSensorDecimalDigits. For example, if the value is 1 and
|
|
transferSwitchSensorDecimalDigits is 2, then actual value is 0.01.
|
|
This value is undefined for sensors whose range exceeds the
|
|
Integer32 range (-2147483648 .. 2147483647).
|
|
This parameter does not apply to sensors without numerical reading,
|
|
e.g. operational state or switch fault sensors."
|
|
::= { transferSwitchSensorMeasurementsEntry 6 }
|
|
|
|
|
|
|
|
-- the OutletSwitchControlTable
|
|
|
|
-- The OutletSwitchControl table implements switching of outlets.
|
|
|
|
|
|
outletSwitchControlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OutletSwitchControlEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of outlets for a PDU. The number of
|
|
entries is given by the value of outletCount."
|
|
::= { outletControl 2 }
|
|
|
|
outletSwitchControlEntry OBJECT-TYPE
|
|
SYNTAX OutletSwitchControlEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry for implementing switching operations on an outlet."
|
|
INDEX { pduId, outletId }
|
|
::= { outletSwitchControlTable 1 }
|
|
|
|
OutletSwitchControlEntryStruct ::= SEQUENCE {
|
|
switchingOperation OutletSwitchingOperationsEnumeration,
|
|
outletSwitchingState SensorStateEnumeration,
|
|
outletSwitchingTimeStamp Unsigned32
|
|
}
|
|
|
|
|
|
|
|
switchingOperation OBJECT-TYPE
|
|
SYNTAX OutletSwitchingOperationsEnumeration
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The switching operation."
|
|
::= { outletSwitchControlEntry 2 }
|
|
|
|
|
|
outletSwitchingState OBJECT-TYPE
|
|
SYNTAX SensorStateEnumeration
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The outlet state at present"
|
|
::= { outletSwitchControlEntry 3 }
|
|
|
|
|
|
outletSwitchingTimeStamp OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The timestamp indicating when the outlet was last switched"
|
|
::= { outletSwitchControlEntry 4 }
|
|
|
|
|
|
-- the transferSwitchControlTable
|
|
|
|
-- The TransferSwitchControl table implements control operations of transfer switches.
|
|
|
|
|
|
transferSwitchControlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TransferSwitchControlEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of transfer switches for a PDU. The number of
|
|
entries is given by the value of transferSwitchCount."
|
|
::= { transferSwitchControl 1 }
|
|
|
|
transferSwitchControlEntry OBJECT-TYPE
|
|
SYNTAX TransferSwitchControlEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry for implementing switching operations on a transfer switch."
|
|
INDEX { pduId, transferSwitchId }
|
|
::= { transferSwitchControlTable 1 }
|
|
|
|
TransferSwitchControlEntryStruct ::= SEQUENCE {
|
|
transferSwitchActiveInlet Integer32,
|
|
transferSwitchTransferToInlet Integer32,
|
|
transferSwitchAlarmOverride TruthValue,
|
|
transferSwitchLastTransferReason TransferSwitchTransferReasonEnumeration
|
|
}
|
|
|
|
transferSwitchActiveInlet OBJECT-TYPE
|
|
SYNTAX Integer32(1..64)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index of the currently active inlet."
|
|
::= { transferSwitchControlEntry 1 }
|
|
|
|
transferSwitchTransferToInlet OBJECT-TYPE
|
|
SYNTAX Integer32(1..64)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Select the active inlet. If the new inlet is available, it will become
|
|
both active and preferred, otherwise an inconsistentValue error will
|
|
be returned.
|
|
By default the switching operation will fail if the phase difference
|
|
between the inlets is too large. In this case the switch can be forced
|
|
by writing transferSwitchAlarmOverride as True in the same request.
|
|
This variable will always read as 0."
|
|
::= { transferSwitchControlEntry 2 }
|
|
|
|
transferSwitchAlarmOverride OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Force transfer even if the phase difference between the inlets is too
|
|
large.
|
|
This may only be written together with transferSwitchTransferToInlet,
|
|
otherwise an inconsistentValue error will be returned. Always reads as
|
|
false."
|
|
::= { transferSwitchControlEntry 3 }
|
|
|
|
transferSwitchLastTransferReason OBJECT-TYPE
|
|
SYNTAX TransferSwitchTransferReasonEnumeration
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The reason for the most recent transfer"
|
|
::= { transferSwitchControlEntry 4 }
|
|
|
|
|
|
-- the actuatorControlTable
|
|
|
|
-- The actuatorControl table implements user-initiated state changes for an actuator.
|
|
|
|
|
|
actuatorControlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ActuatorControlEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of actuators for a PDU. "
|
|
::= { actuatorControl 2 }
|
|
|
|
actuatorControlEntry OBJECT-TYPE
|
|
SYNTAX ActuatorControlEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry for implementing user-initiated state changes for an actuator."
|
|
INDEX { pduId, sensorID }
|
|
::= { actuatorControlTable 1 }
|
|
|
|
ActuatorControlEntryStruct ::= SEQUENCE {
|
|
actuatorState SensorStateEnumeration
|
|
}
|
|
|
|
|
|
|
|
|
|
actuatorState OBJECT-TYPE
|
|
SYNTAX SensorStateEnumeration
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The actuator state.
|
|
A Get operation retrieves the state of the actuator.
|
|
A Set operation changes the stae of the sensor.
|
|
The valid states for set operations are on and Off.
|
|
Attempting to set the state to any other value will generate an error. "
|
|
::= { actuatorControlEntry 2 }
|
|
|
|
|
|
-- the RCM (Residual Control Monitor) Self Test Table
|
|
|
|
-- The rcmSelfTest table implements self test of the RCM.
|
|
|
|
|
|
rcmSelfTestTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RcmSelfTestEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of RCMs. "
|
|
::= { rcmControl 2 }
|
|
|
|
rcmSelfTestEntry OBJECT-TYPE
|
|
SYNTAX RcmSelfTestEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry for implementing self test of an RCM."
|
|
INDEX { pduId, inletId }
|
|
::= { rcmSelfTestTable 1 }
|
|
|
|
RcmSelfTestEntryStruct ::= SEQUENCE {
|
|
rcmState SensorStateEnumeration
|
|
}
|
|
|
|
|
|
|
|
|
|
rcmState OBJECT-TYPE
|
|
SYNTAX SensorStateEnumeration
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The rcm state.
|
|
A Get operation retrieves the state of the RCM State Sensor.
|
|
A Set operation changes the state of the sensor.
|
|
The valid state for set operations is selfTest.
|
|
When rcmState is set to selfTest, self test of the RCM starts.
|
|
Attempting to set the state to any other value will generate an error.
|
|
If the current state is selfTest, then an attempt to set the value to selfTest
|
|
will be ignored.
|
|
|
|
"
|
|
::= { rcmSelfTestEntry 2 }
|
|
|
|
|
|
-- the InletSensorControlTable
|
|
|
|
-- The InletSensorControl table implements operations on inlet sensors
|
|
|
|
inletSensorControlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF InletSensorControlEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of control entries for the inlet sensors of a PDU. The set
|
|
of valid indexes is defined by the value of inletCount and the
|
|
inletDeviceCapabilities entry for the selected inlet."
|
|
::= { inletSensorControl 1 }
|
|
|
|
inletSensorControlEntry OBJECT-TYPE
|
|
SYNTAX InletSensorControlEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry used for controlling an inlet sensor."
|
|
INDEX { pduId, inletId, sensorType }
|
|
::= { inletSensorControlTable 1 }
|
|
|
|
InletSensorControlEntryStruct ::= SEQUENCE {
|
|
inletSensorResetValue Integer32
|
|
}
|
|
|
|
inletSensorResetValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Writing to this variable sets a new value for the addressed sensor. Only
|
|
accumulating sensors (e.g. energy counters) can be reset, and currently
|
|
the only supported value is 0. Writing any other value returns an error.
|
|
This variable will always read as 0."
|
|
::= { inletSensorControlEntry 1 }
|
|
|
|
|
|
-- the OutletSensorControlTable
|
|
|
|
-- The OutletSensorControl table implements operations on outlet sensors
|
|
|
|
outletSensorControlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OutletSensorControlEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of control entries for the outlet sensors of a PDU. The set
|
|
of valid indexes is defined by the value of outletCount and the
|
|
outletDeviceCapabilities entry for the selected outlet."
|
|
::= { outletSensorControl 1 }
|
|
|
|
outletSensorControlEntry OBJECT-TYPE
|
|
SYNTAX OutletSensorControlEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry used for controlling an outlet sensor."
|
|
INDEX { pduId, outletId, sensorType }
|
|
::= { outletSensorControlTable 1 }
|
|
|
|
OutletSensorControlEntryStruct ::= SEQUENCE {
|
|
outletSensorResetValue Integer32
|
|
}
|
|
|
|
outletSensorResetValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Writing to this variable sets a new value for the addressed sensor. Only
|
|
accumulating sensors (e.g. energy counters) can be reset, and currently
|
|
the only supported value is 0. Writing any other value returns an error.
|
|
This variable will always read as 0."
|
|
::= { outletSensorControlEntry 1 }
|
|
|
|
-- the UnitSensorControlTable
|
|
|
|
-- The UnitSensorControl table implements operations on pdu sensors
|
|
|
|
unitSensorControlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UnitSensorControlEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of control entries for the global sensors of a PDU. The set
|
|
of valid indexes is defined by the value of pduCount and the
|
|
pduDeviceCapabilities entry."
|
|
::= { unitSensorControl 1 }
|
|
|
|
unitSensorControlEntry OBJECT-TYPE
|
|
SYNTAX UnitSensorControlEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry used for controlling an global sensor."
|
|
INDEX { pduId, sensorType }
|
|
::= { unitSensorControlTable 1 }
|
|
|
|
UnitSensorControlEntryStruct ::= SEQUENCE {
|
|
unitSensorResetValue Integer32
|
|
}
|
|
|
|
unitSensorResetValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Writing to this variable sets a new value for the addressed sensor. Only
|
|
accumulating sensors (e.g. energy counters) can be reset, and currently
|
|
the only supported value is 0. Writing any other value returns an error.
|
|
This variable will always read as 0."
|
|
::= { unitSensorControlEntry 1 }
|
|
|
|
-- the ReliabilityData table
|
|
|
|
-- The ReliabilityData table contains reliability data for the PDU.
|
|
|
|
|
|
reliabilityDataTableSequenceNumber OBJECT-TYPE
|
|
SYNTAX Integer32(1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sequence number for updates to the reliability data table"
|
|
::= { reliabilityData 1 }
|
|
|
|
|
|
reliabilityDataTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ReliabilityDataEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of PDU reliability data entries."
|
|
::= { reliabilityData 2 }
|
|
|
|
reliabilityDataEntry OBJECT-TYPE
|
|
SYNTAX ReliabilityDataEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing reliability data for a particular PDU."
|
|
INDEX { reliabilityIndex }
|
|
::= { reliabilityDataTable 1 }
|
|
|
|
ReliabilityDataEntryStruct ::= SEQUENCE {
|
|
reliabilityIndex Integer32,
|
|
reliabilityId DisplayString,
|
|
reliabilityDataValue Unsigned32,
|
|
reliabilityDataMaxPossible Unsigned32,
|
|
reliabilityDataWorstValue Unsigned32,
|
|
reliabilityDataThreshold Unsigned32,
|
|
reliabilityDataRawUpperBytes Unsigned32,
|
|
reliabilityDataRawLowerBytes Unsigned32,
|
|
reliabilityDataFlags BITS
|
|
}
|
|
|
|
|
|
|
|
reliabilityIndex OBJECT-TYPE
|
|
SYNTAX Integer32(1..4096)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index of the entry in the table."
|
|
::= { reliabilityDataEntry 1 }
|
|
|
|
reliabilityId OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unique ID of the entry.
|
|
POH
|
|
Power on hours.
|
|
|
|
CB.<label>.TRIPCNT
|
|
Trip count of circuit breaker with label <label>.
|
|
|
|
CTRL.<serial>.<addr>.MASTER.CSUMERRLASTHOUR
|
|
Number of checksum errors in slave (controller board) to master (CPU
|
|
board) communication in the last hour on controller with serial
|
|
number <serial> and bus address <addr>.
|
|
|
|
CTRL.<serial>.<addr>.SLAVE.CSUMERRLASTHOUR
|
|
Number of checksum errors in master (CPU board) to slave (controller
|
|
board) communication in the last hour on controller with serial
|
|
number <serial> and bus address <addr>.
|
|
|
|
CTRL.<serial>.<addr>.TOUTLASTHOUR
|
|
Number of communication timeouts to controller with serial
|
|
number <serial> and bus address <addr> in the last hour.
|
|
|
|
CTRL.<serial>.<addr>.RLY.<num>.CYCLECNT
|
|
Number of cycles the relay <num> on the controller board with serial
|
|
number <serial> and bus address <addr> has made. A cycle is an
|
|
off->on followed by an on->off event later. The count is increased on
|
|
the off->on transition.
|
|
|
|
CTRL.<serial>.<addr>.RLY.<num>.FAILLASTHOUR
|
|
Number of failed switching operations on relay <num> on the controller
|
|
board with serial number <serial> and bus address <addr> in the last
|
|
hour. It depends on the specific controller board hardware and what
|
|
error conditions are detected.
|
|
"
|
|
::= { reliabilityDataEntry 2 }
|
|
|
|
|
|
reliabilityDataValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The normalized value"
|
|
::= { reliabilityDataEntry 3 }
|
|
|
|
reliabilityDataMaxPossible OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum possible normalized value"
|
|
::= { reliabilityDataEntry 4 }
|
|
|
|
|
|
reliabilityDataWorstValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The worst normalized value seen so far"
|
|
::= { reliabilityDataEntry 5 }
|
|
|
|
reliabilityDataThreshold OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The normalized Threshold value "
|
|
::= { reliabilityDataEntry 6 }
|
|
|
|
reliabilityDataRawUpperBytes OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Upper 4 bytes of the raw ( not normalized) data.
|
|
reliabilityDataRawUpperBytes and reliabilityDataRawLowerBytes
|
|
should be combined and interpreted as a signed 64-bit value"
|
|
::= { reliabilityDataEntry 7 }
|
|
|
|
reliabilityDataRawLowerBytes OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower 4 bytes of the raw ( not normalized) data.
|
|
reliabilityDataRawUpperBytes and reliabilityDataRawLowerBytes
|
|
should be combined and interpreted as a signed 64-bit value"
|
|
::= { reliabilityDataEntry 8 }
|
|
|
|
|
|
|
|
reliabilityDataFlags OBJECT-TYPE
|
|
SYNTAX BITS{
|
|
invalidFlag(0),
|
|
oldValue(1),
|
|
criticalEntry(2)
|
|
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Flags"
|
|
::= { reliabilityDataEntry 9 }
|
|
|
|
|
|
|
|
|
|
|
|
-- the ReliabilityErrorLog table
|
|
|
|
-- The ReliabilityErrorLog table contains the reliability ErrorLog for the PDU.
|
|
|
|
|
|
reliabilityErrorLogTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ReliabilityErrorLogEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of PDU reliability ErrorLog entries. "
|
|
::= { reliabilityErrorLog 2 }
|
|
|
|
reliabilityErrorLogEntry OBJECT-TYPE
|
|
SYNTAX ReliabilityErrorLogEntryStruct
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing reliability ErrorLog data for a particular PDU."
|
|
INDEX { reliabilityErrorLogIndex }
|
|
::= { reliabilityErrorLogTable 1 }
|
|
|
|
ReliabilityErrorLogEntryStruct ::= SEQUENCE {
|
|
reliabilityErrorLogIndex Integer32,
|
|
reliabilityErrorLogId DisplayString,
|
|
reliabilityErrorLogValue Unsigned32,
|
|
reliabilityErrorLogThreshold Unsigned32,
|
|
reliabilityErrorLogRawUpperBytes Unsigned32,
|
|
reliabilityErrorLogRawLowerBytes Unsigned32,
|
|
reliabilityErrorLogPOH Unsigned32,
|
|
reliabilityErrorLogTime Unsigned32
|
|
}
|
|
|
|
|
|
|
|
reliabilityErrorLogIndex OBJECT-TYPE
|
|
SYNTAX Integer32(1..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index of the entry in the table."
|
|
::= { reliabilityErrorLogEntry 1 }
|
|
|
|
|
|
reliabilityErrorLogId OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unique ID of the entry.
|
|
POH
|
|
Power on hours.
|
|
|
|
CB.<label>.TRIPCNT
|
|
Trip count of circuit breaker with label <label>.
|
|
|
|
CTRL.<serial>.<addr>.MASTER.CSUMERRLASTHOUR
|
|
Number of checksum errors in slave (controller board) to master (CPU
|
|
board) communication in the last hour on controller with serial
|
|
number <serial> and bus address <addr>.
|
|
|
|
CTRL.<serial>.<addr>.SLAVE.CSUMERRLASTHOUR
|
|
Number of checksum errors in master (CPU board) to slave (controller
|
|
board) communication in the last hour on controller with serial
|
|
number <serial> and bus address <addr>.
|
|
|
|
CTRL.<serial>.<addr>.TOUTLASTHOUR
|
|
Number of communication timeouts to controller with serial
|
|
number <serial> and bus address <addr> in the last hour.
|
|
|
|
CTRL.<serial>.<addr>.RLY.<num>.CYCLECNT
|
|
Number of cycles the relay <num> on the controller board with serial
|
|
number <serial> and bus address <addr> has made. A cycle is an
|
|
off->on followed by an on->off event later. The count is increased on
|
|
the off->on transition.
|
|
|
|
CTRL.<serial>.<addr>.RLY.<num>.FAILLASTHOUR
|
|
Number of failed switching operations on relay <num> on the controller
|
|
board with serial number <serial> and bus address <addr> in the last
|
|
hour. It depends on the specific controller board hardware and what
|
|
error conditions are detected.
|
|
|
|
"
|
|
::= { reliabilityErrorLogEntry 2 }
|
|
|
|
|
|
|
|
reliabilityErrorLogValue OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The normalized value"
|
|
::= { reliabilityErrorLogEntry 3 }
|
|
|
|
|
|
|
|
reliabilityErrorLogThreshold OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The normalized Threshold value "
|
|
::= { reliabilityErrorLogEntry 6 }
|
|
|
|
reliabilityErrorLogRawUpperBytes OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Upper 4 bytes of the raw ( not normalized) data.
|
|
reliabilityDataRawUpperBytes and reliabilityDataRawLowerBytes
|
|
should be combined and interpreted as a signed 64-bit value"
|
|
::= { reliabilityErrorLogEntry 7 }
|
|
|
|
reliabilityErrorLogRawLowerBytes OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower 4 bytes of the raw ( not normalized) data.
|
|
reliabilityDataRawUpperBytes and reliabilityDataRawLowerBytes
|
|
should be combined and interpreted as a signed 64-bit value"
|
|
::= { reliabilityErrorLogEntry 8 }
|
|
|
|
reliabilityErrorLogPOH OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time of occurrence of the event measured from the last
|
|
time the PDU was powered on"
|
|
::= { reliabilityErrorLogEntry 9 }
|
|
|
|
reliabilityErrorLogTime OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UTC time of occurrence of the event "
|
|
::= { reliabilityErrorLogEntry 10 }
|
|
|
|
|
|
-- Start the traps
|
|
-- All traps contain the pxInetIPAddressType and pxInetIPAddress fields.
|
|
-- For IPv4, these parameters contain the IP Address Type and IP address
|
|
-- For IPv6, these parameters are not used
|
|
|
|
|
|
systemStarted NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system has started.
|
|
"
|
|
::= { traps 1 }
|
|
|
|
systemReset NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
userName,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system was reset. The conditions under which
|
|
this trap is sent include, but are not limited to, the following.
|
|
using the GUI - Maintenance->Reset Unit
|
|
using the CLI - reset pdu unit"
|
|
::= { traps 2 }
|
|
|
|
userLogin NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
userName,
|
|
pxIPAddress,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A user logged in."
|
|
::= { traps 3 }
|
|
|
|
userLogout NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
userName,
|
|
pxIPAddress,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A user logged out."
|
|
::= { traps 4 }
|
|
|
|
userAuthenticationFailure NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
userName,
|
|
pxIPAddress,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A user authentication attempt failed."
|
|
::= { traps 5 }
|
|
|
|
userSessionTimeout NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
userName,
|
|
pxIPAddress,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A user session timed out."
|
|
::= { traps 8 }
|
|
|
|
userAdded NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
userName,
|
|
targetUser,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A user was added to the system."
|
|
::= { traps 11 }
|
|
|
|
userModified NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
userName,
|
|
targetUser,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A user was modified."
|
|
::= { traps 12 }
|
|
|
|
userDeleted NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
userName,
|
|
targetUser,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A user was deleted from the system."
|
|
::= { traps 13 }
|
|
|
|
roleAdded NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
userName,
|
|
roleName,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A role was added to the system."
|
|
::= { traps 14 }
|
|
|
|
roleModified NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
userName,
|
|
roleName,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A role was modified."
|
|
::= { traps 15 }
|
|
|
|
|
|
roleDeleted NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
userName,
|
|
roleName,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A role was deleted from the system."
|
|
::= { traps 16 }
|
|
|
|
deviceUpdateStarted NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
userName,
|
|
pxIPAddress,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
imageVersion,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The device update has started."
|
|
::= { traps 20 }
|
|
|
|
deviceUpdateCompleted NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
userName,
|
|
pxIPAddress,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
imageVersion,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The device update has completed."
|
|
::= { traps 21 }
|
|
|
|
userBlocked NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
userName,
|
|
pxIPAddress,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A blocked user tried to log in."
|
|
::= { traps 22 }
|
|
|
|
powerControl NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
userName,
|
|
pxIPAddress,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
outletLabel,
|
|
measurementsOutletSensorState,
|
|
switchingOperation,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An outlet switching operation has been performed.
|
|
Note that measurementsOutletSensorState represents the state of the outlet at the time the trap was sent.
|
|
This may be different from the final state of the outlet. For instance,
|
|
if the outlet is cycled and the outlet cycle delay is 20 seconds, this variable will
|
|
indicate OFF although the final state of the outlet will be ON. The final state of the
|
|
outlet will be indicated in the outletSensorStateChange trap for the outlet onOff sensor."
|
|
::= { traps 23 }
|
|
|
|
|
|
|
|
userPasswordChanged NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
userName,
|
|
targetUser,
|
|
pxIPAddress,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"User password was changed."
|
|
::= { traps 24 }
|
|
|
|
passwordSettingsChanged NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
userName,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Strong password settings changed."
|
|
::= { traps 28 }
|
|
|
|
|
|
|
|
|
|
|
|
firmwareValidationFailed NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
userName,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Firmware validation failed."
|
|
::= { traps 38 }
|
|
|
|
|
|
|
|
logFileCleared NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
userName,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The log file has been cleared."
|
|
::= { traps 41 }
|
|
|
|
|
|
|
|
|
|
|
|
|
|
bulkConfigurationSaved NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
userName,
|
|
pxIPAddress,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Bulk Configuration saved."
|
|
::= { traps 53 }
|
|
|
|
bulkConfigurationCopied NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
userName,
|
|
pxIPAddress,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Bulk Configuration copied to the device."
|
|
::= { traps 54 }
|
|
|
|
|
|
|
|
pduSensorStateChange NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
pduName,
|
|
pduNumber,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
typeOfSensor,
|
|
measurementsUnitSensorTimeStamp,
|
|
measurementsUnitSensorValue,
|
|
measurementsUnitSensorState,
|
|
measurementsUnitSensorSignedValue,
|
|
oldSensorState,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation }
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"PDU Sensor State Change.
|
|
Which value field to use depends on the metadata of the sensor.
|
|
measurementsUnitSensorValue is undefined for sensors which can
|
|
have negative readings, measurementsUnitSensorSignedValue is
|
|
undefined for sensors whose range exceeds the Integer32 range.
|
|
Both fields do not apply to sensors without numerical readings."
|
|
::= { traps 60 }
|
|
|
|
inletSensorStateChange NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
pduName,
|
|
pduNumber,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
inletLabel,
|
|
typeOfSensor,
|
|
measurementsInletSensorTimeStamp,
|
|
measurementsInletSensorValue,
|
|
measurementsInletSensorState,
|
|
measurementsInletSensorSignedValue,
|
|
oldSensorState,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Inlet Sensor State Change.
|
|
Which value field to use depends on the metadata of the sensor.
|
|
measurementsInletSensorValue is undefined for sensors which can
|
|
have negative readings, measurementsInletSensorSignedValue is
|
|
undefined for sensors whose range exceeds the Integer32 range.
|
|
Both fields do not apply to sensors without numerical readings.
|
|
|
|
For an rcmState sensor transitioning to the fail state, the value is the residual current
|
|
just before the sensor transitioned to the fail state i.e.
|
|
if typeOfSensor = rcmState and measurementsInletSensorState = fail,
|
|
then measurementsInletSensorValue = the residual current just before the sensor transitioned to the fail state
|
|
"
|
|
::= { traps 61 }
|
|
|
|
inletPoleSensorStateChange NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
pduName,
|
|
pduNumber,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
inletLabel,
|
|
inletPoleNumber,
|
|
typeOfSensor,
|
|
measurementsInletPoleSensorTimeStamp,
|
|
measurementsInletPoleSensorValue,
|
|
measurementsInletPoleSensorState,
|
|
measurementsInletPoleSensorSignedValue,
|
|
oldSensorState,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Inlet Pole Sensor State Change.
|
|
Which value field to use depends on the metadata of the sensor.
|
|
measurementsInletPoleSensorValue is undefined for sensors which can
|
|
have negative readings, measurementsInletPoleSensorSignedValue is
|
|
undefined for sensors whose range exceeds the Integer32 range.
|
|
Both fields do not apply to sensors without numerical readings."
|
|
::= { traps 62 }
|
|
|
|
outletSensorStateChange NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
pduName,
|
|
pduNumber,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
outletLabel,
|
|
typeOfSensor,
|
|
measurementsOutletSensorTimeStamp,
|
|
measurementsOutletSensorValue,
|
|
measurementsOutletSensorState,
|
|
measurementsOutletSensorSignedValue,
|
|
oldSensorState,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Outlet Sensor State Change.
|
|
Which value field to use depends on the metadata of the sensor.
|
|
measurementsOutletSensorValue is undefined for sensors which can
|
|
have negative readings, measurementsOutletSensorSignedValue is
|
|
undefined for sensors whose range exceeds the Integer32 range.
|
|
Both fields do not apply to sensors without numerical readings."
|
|
::= { traps 63 }
|
|
|
|
outletPoleSensorStateChange NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
pduName,
|
|
pduNumber,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
outletLabel,
|
|
outletPoleNumber,
|
|
typeOfSensor,
|
|
measurementsOutletPoleSensorTimeStamp,
|
|
measurementsOutletPoleSensorValue,
|
|
measurementsOutletPoleSensorState,
|
|
measurementsOutletPoleSensorSignedValue,
|
|
oldSensorState,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Outlet Pole Sensor State Change.
|
|
Which value field to use depends on the metadata of the sensor.
|
|
measurementsOutletPoleSensorValue is undefined for sensors which can
|
|
have negative readings, measurementsOutletPoleSensorSignedValue is
|
|
undefined for sensors whose range exceeds the Integer32 range.
|
|
Both fields do not apply to sensors without numerical readings."
|
|
::= { traps 64 }
|
|
|
|
overCurrentProtectorSensorStateChange NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
pduName,
|
|
pduNumber,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
overCurrentProtectorLabel,
|
|
typeOfSensor,
|
|
measurementsOverCurrentProtectorSensorTimeStamp,
|
|
measurementsOverCurrentProtectorSensorValue,
|
|
measurementsOverCurrentProtectorSensorState,
|
|
measurementsOverCurrentProtectorSensorSignedValue,
|
|
oldSensorState,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Overcurrent Protector Sensor State Change.
|
|
Which value field to use depends on the metadata of the sensor.
|
|
measurementsOverCurrentProtectorSensorValue is undefined for sensors which can
|
|
have negative readings, measurementsOverCurrentProtectorSensorSignedValue is
|
|
undefined for sensors whose range exceeds the Integer32 range.
|
|
Both fields do not apply to sensors without numerical readings."
|
|
::= { traps 65 }
|
|
|
|
externalSensorStateChange NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
pduName,
|
|
pduNumber,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
externalSensorNumber,
|
|
typeOfSensor,
|
|
measurementsExternalSensorTimeStamp,
|
|
measurementsExternalSensorValue,
|
|
measurementsExternalSensorState ,
|
|
oldSensorState,
|
|
externalSensorSerialNumber,
|
|
externalOnOffSensorSubtype,
|
|
externalSensorChannelNumber,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"External Sensor State Change."
|
|
::= { traps 66 }
|
|
|
|
|
|
smtpMessageTransmissionFailure NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
smtpMessageRecipients,
|
|
smtpServer,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SMTP message transmission failure"
|
|
::= { traps 67 }
|
|
|
|
|
|
ldapError NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
errorDescription,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"LDAP Error occurred; errorDescription describes the error"
|
|
::= { traps 68 }
|
|
|
|
deviceUpdateFailed NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
userName,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
imageVersion,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The device update has failed."
|
|
::= { traps 70 }
|
|
|
|
loadSheddingModeEntered NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
userName,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The PX has enetered Load Shedding Mode"
|
|
::= { traps 71 }
|
|
|
|
loadSheddingModeExited NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
userName,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The PX has exited Load Shedding Mode"
|
|
::= { traps 72 }
|
|
|
|
pingServerEnabled NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
userName,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
serverIPAddress,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ping feature has been enabled"
|
|
::= { traps 73 }
|
|
|
|
pingServerDisabled NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
userName,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
serverIPAddress,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ping feature has been disabled"
|
|
::= { traps 74 }
|
|
|
|
serverNotReachable NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
serverIPAddress,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The server is not reachable"
|
|
::= { traps 75 }
|
|
|
|
serverReachable NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
serverIPAddress,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The server is reachable"
|
|
::= { traps 76 }
|
|
|
|
rfCodeTagConnected NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The RF Code Tag is Connected"
|
|
::= { traps 77 }
|
|
|
|
rfCodeTagDisconnected NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The RF Code Tag is Disconnected"
|
|
::= { traps 78 }
|
|
|
|
|
|
deviceIdentificationChanged NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
userName,
|
|
deviceChangedParameter,
|
|
changedParameterNewValue,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device identification has changed"
|
|
::= { traps 79 }
|
|
|
|
usbSlaveConnected NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"USB Connectivity to slave has been established"
|
|
::= { traps 80 }
|
|
|
|
usbSlaveDisconnected NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"USB Connectivity to slave has been lost"
|
|
::= { traps 81 }
|
|
|
|
lhxSupportChanged NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
userName,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation,
|
|
lhxSupportEnabled
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Schroff LHX Support has been either enabled or disabled."
|
|
::= { traps 82 }
|
|
|
|
userAcceptedRestrictedServiceAgreement NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
userName,
|
|
pxIPAddress,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The user accepted the Restricted Service Agreement."
|
|
::= { traps 83 }
|
|
|
|
userDeclinedRestrictedServiceAgreement NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
userName,
|
|
pxIPAddress,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The user declined the Restricted Service Agreement."
|
|
::= { traps 84 }
|
|
|
|
wireSensorStateChange NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
pduNumber,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
wireLabel,
|
|
typeOfSensor,
|
|
measurementsWireSensorTimeStamp,
|
|
measurementsWireSensorValue,
|
|
measurementsWireSensorState,
|
|
oldSensorState,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation
|
|
}
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Wire Sensor State Change."
|
|
::= { traps 85 }
|
|
|
|
|
|
transferSwitchSensorStateChange NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
pduNumber,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
transferSwitchLabel,
|
|
typeOfSensor,
|
|
measurementsTransferSwitchSensorTimeStamp,
|
|
measurementsTransferSwitchSensorValue,
|
|
measurementsTransferSwitchSensorState,
|
|
measurementsTransferSwitchSensorSignedValue,
|
|
oldSensorState,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation,
|
|
transferSwitchLastTransferReason
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Transfer Switch Sensor State Change.
|
|
Which value field to use depends on the metadata of the sensor.
|
|
measurementsTransferSwitchSensorValue is undefined for sensors which can
|
|
have negative readings, measurementsTransferSwitchSensorSignedValue is
|
|
undefined for sensors whose range exceeds the Integer32 range.
|
|
Both fields do not apply to sensors without numerical readings."
|
|
::= { traps 86 }
|
|
|
|
|
|
deviceSettingsSaved NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
userName,
|
|
pxIPAddress,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device Settings have been saved."
|
|
::= { traps 88 }
|
|
|
|
deviceSettingsRestored NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
userName,
|
|
pxIPAddress,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device Settings have been restored."
|
|
::= { traps 89 }
|
|
|
|
webcamInserted NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
webcamModel,
|
|
webcamConnectionPort,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A webcam has been inserted"
|
|
::= { traps 90 }
|
|
|
|
webcamRemoved NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
webcamModel,
|
|
webcamConnectionPort,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A webcam has been removed"
|
|
::= { traps 91 }
|
|
|
|
inletEnabled NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
userName,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
inletLabel,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PDU operation has been enabled for an inlet"
|
|
::= { traps 92 }
|
|
|
|
inletDisabled NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
userName,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
inletLabel,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PDU operation has been disabled for an inlet"
|
|
::= { traps 93 }
|
|
|
|
serverConnectivityUnrecoverable NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
serverIPAddress,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The connection to the server could not be recovered"
|
|
::= { traps 94 }
|
|
|
|
|
|
radiusError NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
errorDescription,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"LDAP Error occurred; errorDescription describes the error"
|
|
::= { traps 95 }
|
|
|
|
|
|
serverReachabilityError NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
serverIPAddress,
|
|
errorDescription,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Server Reachability Error occurred; errorDescription describes the error.
|
|
This trap is sent when the Error state is entered.
|
|
Reasons for transitioning to the Error state include the following:
|
|
Unable to resolve the server hostname. "
|
|
::= { traps 96 }
|
|
|
|
inletSensorReset NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
userName,
|
|
pduNumber,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
inletLabel,
|
|
typeOfSensor,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An inlet sensor was reset."
|
|
::= { traps 97 }
|
|
|
|
outletSensorReset NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
userName,
|
|
pduNumber,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
outletLabel,
|
|
typeOfSensor,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An outlet sensor was reset."
|
|
::= { traps 98 }
|
|
|
|
unknownPeripheralDeviceAttached NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
peripheralDeviceRomcode,
|
|
peripheralDevicePackagePosition,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An unknown peripheral device was attached."
|
|
::= { traps 99 }
|
|
|
|
peripheralDeviceFirmwareUpdate NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
peripheralDevicePackageSerialNumber,
|
|
peripheralDeviceFirmwareUpdateState,
|
|
peripheralDevicePackageFirmwareVersion,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The firmware update state of a peripheral device changed while
|
|
performing update to peripheralDevicePackageFirmwareVersion."
|
|
::= { traps 100 }
|
|
|
|
unitSensorReset NOTIFICATION-TYPE
|
|
OBJECTS { pduName,
|
|
userName,
|
|
pduNumber,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
typeOfSensor,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A global sensor was reset."
|
|
::= { traps 101 }
|
|
|
|
unitSensorStateChange NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
pduName,
|
|
pduNumber,
|
|
pxInetAddressType,
|
|
pxInetIPAddress,
|
|
agentInetPortNumber,
|
|
typeOfSensor,
|
|
measurementsUnitSensorTimeStamp,
|
|
measurementsUnitSensorValue,
|
|
measurementsUnitSensorState,
|
|
measurementsUnitSensorSignedValue,
|
|
oldSensorState,
|
|
sysContact,
|
|
sysName,
|
|
sysLocation }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unit Sensor State Change.
|
|
Which value field to use depends on the metadata of the sensor.
|
|
measurementsUnitSensorValue is undefined for sensors which can
|
|
have negative readings, measurementsUnitSensorSignedValue is
|
|
undefined for sensors whose range exceeds the Integer32 range.
|
|
Both fields do not apply to sensors without numerical readings."
|
|
::= { traps 102 }
|
|
|
|
END
|