-- FILE NAME : mca.mib
-- DATE : December 20, 2004
-- AUTHOR : Greg Saltis
-- PROJECT : Vortex Ethernet Card
-- PUBLIC :
-- PRIVATE :
-- COPYRIGHT : Copyright (C) 2004 by Emerson Network Power
-- ******************************************************************************
-- ******************************************************************************
-- MODIFICATION HISTORY
--
-- v1.0.0.0 09-06-04 grs New File.
-- v1.0.0.1 12-20-04 grs Add Modification history
-- Add
-- vecMCAInformation
-- vecMCAMessageRequests
-- vecMCAMessageTransmissions
-- vecMCAMessageTransmissions
-- vecMCAMessageBadCRCs
-- vecMCAMessageLinkErrors
-- vecMCAMessagePartialResponses
-- vecMCAMessageWrongPackets
-- v1.0.0.2 01-29-05 gp
-- Add
-- vecMCAMessageErrorReplies
-- Remove
-- vecAlarmLVDAlarm
-- vecAlarmPCUFailAlarm
-- vecAlarmAudibleAlarmsAreQuiet
-- vecAlarmACFail
-- vecAlarmPasswordHasBeenViewed
-- vecAlarmAudibleRelayDeEnergized
-- v1.0.0.3 07-05-05 gp
-- Add vecAnalogBatteryReserveHours
--
-- v2.0.0.3 07-12-05 gp
-- Add
-- vecAlarmBatteryPoorHealth
-- vecAlarmBatteryReserveLow
--
-- Grouped all battery related traps together.
--
-- v2.0.0.4 10-05-05 gp
-- Add versioning mechanism to MIB. Version information is
-- added to DEFINITIONS statement as follows:
-- VEC-MIBvX DEFINITIONS ::=
--
-- v3.0 10-31-05 gp
-- Add
-- vecHVSActive
-- vecRemoteHVSActive
-- vecRemoteEstopActive
--
-- v4.0 12-13-05 gp
-- Changed company name
-- Revamped to highlight power system information.
--
-- 12-15-05 gp
-- Corrected incorrect labeling for PCU Total current.
--
-- v5.0 12-16-05 gp
-- VEC no longer issues traps for the following MCA alarm conditions:
-- general LVD No Reply alarm
-- general LVD Board Fail alarm
-- general Temperature Sensor Hi or Lo alarm
-- general Temperature Sensor High alarm
-- general Temperature Sensor Low alarm
-- general Temperature Sensor No Reply alarm
-- general Shunt Type alarm
-- general Shunt No Reply alarm
--
-- v5.1 8-04-08 jws
-- Update IMPORTS
-- Added module identity
-- Removed SIZE clause
--
-- v5.4 9-22-08 jws
-- Changed trap object tables to NOTIFICATION-TYPE
--
-- v5.5 9-23-08 jws
-- Typo correction on psAlarmSysInfoString2
--
-- v5.6 10-01-08 gp
-- Corrected vecMIB OID. Replaced references to vec OID with vecMIB.
--
-- v5.7 02-11-11 gp
-- Add
-- psAlarm
-- psHighestSeverityLevel
-- psTemperatureAlarmStatus
-- psLVDCircuitAAlarmStatus
-- psLVDCircuitBAlarmStatus
-- psShuntAlarmStatus
--
--
-- v5.7 08-28-12 jws
-- Corrected Syntax error invalues of INTEGER
-- spaces removed
-- ******************************************************************************
VEC-MIBv5-9 DEFINITIONS ::=
BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
Integer32, Counter32, enterprises
FROM SNMPv2-SMI
TEXTUAL-CONVENTION, DisplayString, DateAndTime
FROM SNMPv2-TC;
vecMIB MODULE-IDENTITY
LAST-UPDATED "201401140823Z"
ORGANIZATION "
Emerson Energy Systems North America (ESNA)"
CONTACT-INFO "
Emerson Energy Systems North America
1510 Kansas Ave.
Lorain, OH 44052
USA "
DESCRIPTION "
Emerson Energy Systems North America(ESNA) VEC MIB. revision 5.9"
::= { enterprises 885 3 }
-- OBJECTS
emersonESNA OBJECT IDENTIFIER ::= { enterprises 885 }
vecInformation OBJECT IDENTIFIER ::= { vecMIB 1 }
vecMessageStats OBJECT IDENTIFIER ::= { vecInformation 2 }
psStatus OBJECT IDENTIFIER ::= { vecMIB 2 }
psMeasurement OBJECT IDENTIFIER ::= { psStatus 1 }
psTraps OBJECT IDENTIFIER ::= { vecMIB 3 }
psAlarmsGeneral1 OBJECT IDENTIFIER ::= { psTraps 1 }
psAlarmsGeneral2 OBJECT IDENTIFIER ::= { psTraps 2 }
psAlarmsBattery OBJECT IDENTIFIER ::= { psTraps 3 }
-- ENTRIES
vecFirmwareVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"VEC System Firmware Version."
::= { vecInformation 1}
vecMessageRequests OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of message requests."
::= { vecMessageStats 1 }
vecMessageTransmissions OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of messages transmitted."
::= { vecMessageStats 2 }
vecMessageNoResponses OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of no responses."
::= { vecMessageStats 3 }
vecMessageBadCRCs OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of bad CRC checks."
::= { vecMessageStats 4 }
vecMessageLinkErrors OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of link errors."
::= { vecMessageStats 5 }
vecMessagePartialResponses OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of partial responses received."
::= { vecMessageStats 6 }
vecMessageWrongPackets OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of wrong packet numbers detected."
::= { vecMessageStats 7 }
vecMessageErrorReplies OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of error responses received."
::= { vecMessageStats 8 }
psSystemVoltage OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"System Voltage."
::= { psMeasurement 1}
psSystemCurrent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"System Current."
::= { psMeasurement 2}
psSubsystemVoltage OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sub System Voltage."
::= { psMeasurement 3}
psSubsystemCurrent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sub System Current."
::= { psMeasurement 4}
psSenseVoltage OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Sense Voltage."
::= { psMeasurement 5}
psPCUTotalCurrent OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total PCU Current."
::= { psMeasurement 6}
psBatteryCurrent OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total Battery Current."
::= { psMeasurement 7}
psBatteryReserveHours OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Battery Reserve Time."
::= { psMeasurement 8}
psAlarm OBJECT-TYPE
SYNTAX INTEGER {
false(0),
true(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A Power System Alarm Is Active."
::= { psMeasurement 9 }
psHighestSeverityLevel OBJECT-TYPE
SYNTAX INTEGER {
normal(0),
minor(1),
major(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The severity level is the highest active alarm level.
Values: 0 = Normal, 1 = Minor, 2 = Major"
::= { psMeasurement 10}
psNumberOfPCUsInstalled OBJECT-TYPE
SYNTAX Integer32(0..80)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of PCUs installed"
::= { psMeasurement 11}
psNumberOfPCUsCommunicating OBJECT-TYPE
SYNTAX Integer32(0..80)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of PCUs communicating"
::= { psMeasurement 12}
psTemperatureTable OBJECT-TYPE
SYNTAX SEQUENCE OF PSTemperatureEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Temperature Measurement Table."
::= { psStatus 2 }
psTemperatureEntry OBJECT-TYPE
SYNTAX PSTemperatureEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Temperature Measurement Table Entry."
INDEX { psTemperatureIndex }
::= { psTemperatureTable 1 }
PSTemperatureEntry ::= SEQUENCE {
psTemperatureIndex Integer32,
psTemperatureMeasurement DisplayString,
psTemperatureAlarmStatus Integer32
}
psTemperatureIndex OBJECT-TYPE
SYNTAX Integer32(1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Temperature Probe Number "
::= { psTemperatureEntry 1 }
psTemperatureMeasurement OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Temperature Value In Centigrade."
::= { psTemperatureEntry 2 }
psTemperatureAlarmStatus OBJECT-TYPE
SYNTAX INTEGER {
high(0),
low(1),
noreply(2),
none(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Temperature Probe Alarm Status "
::= { psTemperatureEntry 3 }
psLVDTable OBJECT-TYPE
SYNTAX SEQUENCE OF PSLVDEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Low Voltage Disconnect Table."
::= { psStatus 3 }
psLVDEntry OBJECT-TYPE
SYNTAX PSLVDEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Low Voltage Disconnect Table Entry."
INDEX { psLVDIndex }
::= { psLVDTable 1 }
PSLVDEntry ::= SEQUENCE {
psLVDIndex Integer32,
psLVDCircuitA DisplayString,
psLVDCircuitB DisplayString,
psLVDCircuitAAlarmStatus Integer32,
psLVDCircuitBAlarmStatus Integer32
}
psLVDIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"LVD Number "
::= { psLVDEntry 1 }
psLVDCircuitA OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"LVD Circuit A Disconnect Voltage "
::= { psLVDEntry 2 }
psLVDCircuitB OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"LVD Circuit B Disconnect Voltage "
::= { psLVDEntry 3 }
psLVDCircuitAAlarmStatus OBJECT-TYPE
SYNTAX INTEGER {
disconnected(0),
noreply(1),
boardfail(2),
none(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"LVD Circuit A Alarm Status "
::= { psLVDEntry 4 }
psLVDCircuitBAlarmStatus OBJECT-TYPE
SYNTAX INTEGER {
disconnected(0),
noreply(1),
boardfail(2),
none(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"LVD Circuit B Alarm Status "
::= { psLVDEntry 5 }
psDistributionTable OBJECT-TYPE
SYNTAX SEQUENCE OF PSShuntEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Shunt Pod Table"
::= { psStatus 4 }
psShuntEntry OBJECT-TYPE
SYNTAX PSShuntEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Shunt Pod Table Entry."
INDEX { psShuntIndex }
::= { psDistributionTable 1 }
PSShuntEntry ::= SEQUENCE {
psShuntIndex Integer32,
psShuntCurrent DisplayString,
psShuntAlarmStatus Integer32,
psShuntType Integer32
}
psShuntIndex OBJECT-TYPE
SYNTAX Integer32(1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Shunt Pod Number."
::= { psShuntEntry 1 }
psShuntCurrent OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Shunt POD Current."
::= { psShuntEntry 2 }
psShuntAlarmStatus OBJECT-TYPE
SYNTAX INTEGER {
type(0),
noreply(1),
none(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Shunt POD Alarm Status.
Values: 0 = Type, 1 = No Reply, 2 = No Alarm"
::= { psShuntEntry 3 }
psShuntType OBJECT-TYPE
SYNTAX INTEGER {
system(1),
subsystem(2),
battery(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Shunt POD Alarm Status.
Values: 0 = System, 1 = Subsystem, 2 = Battery"
::= { psShuntEntry 4 }
psPCUTable OBJECT-TYPE
SYNTAX SEQUENCE OF PSPCUEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"PCU Table."
::= { psStatus 5 }
psPCUEntry OBJECT-TYPE
SYNTAX PSPCUEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"PCU Table Entry."
INDEX { psPCUIndex }
::= { psPCUTable 1 }
PSPCUEntry ::= SEQUENCE {
psPCUIndex Integer32,
psPCUFail Integer32,
psPCUCurrent Integer32,
psPCUFerroGateway Integer32,
psPCUProductNumber DisplayString,
psPCUSWVersion DisplayString,
psPCUSerialNumber DisplayString,
psPCUCapacity DisplayString
}
psPCUIndex OBJECT-TYPE
SYNTAX Integer32(1..80)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PCU Number."
::= { psPCUEntry 1 }
psPCUFail OBJECT-TYPE
SYNTAX INTEGER {
false(0),
true(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PCU Fail Alarm"
::= { psPCUEntry 2 }
psPCUCurrent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PCU Current"
::= { psPCUEntry 3 }
psPCUFerroGateway OBJECT-TYPE
SYNTAX INTEGER {
false(0),
true(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PCU is a Ferro Gateway Rectifier."
::= { psPCUEntry 4 }
psPCUProductNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rectifier Product Number."
::= { psPCUEntry 5}
psPCUSWVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rectifier Software Revision."
::= { psPCUEntry 6}
psPCUSerialNumber OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rectifier Serial Number."
::= { psPCUEntry 7}
psPCUCapacity OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rectifier Rated Current"
::= { psPCUEntry 8 }
psEmergencyStop NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Emergency Stop Alarm."
::= { psAlarmsGeneral1 1 }
psAlarmVeryLowVoltage NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"50 Percent Battery On Discharge Alarm."
::= { psAlarmsGeneral1 2 }
psAlarmLowVoltage NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Battery On Discharge Alarm."
::= { psAlarmsGeneral1 3 }
psAlarmSystemHighVoltage1 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"High Voltage 1 Alarm."
::= { psAlarmsGeneral1 4 }
psAlarmSystemHighVoltage2 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"High Voltage 2 Alarm."
::= { psAlarmsGeneral1 5 }
psAlarmSubsystemLowVoltage NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Subsystem Low Voltage Alarm."
::= { psAlarmsGeneral1 6 }
psAlarmSubsystemHighVoltage NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Subsystem High Voltage Alarm."
::= { psAlarmsGeneral1 7 }
psAlarmSystemFuse NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"System Fuse Alarm."
::= { psAlarmsGeneral1 8 }
psAlarmSubsystemFuse NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Subsystem Fuse Alarm."
::= { psAlarmsGeneral1 9 }
psAlarmAllACOff NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"All AC Off Alarm."
::= { psAlarmsGeneral1 10 }
psAlarmSystemOverCurrent NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"System Over Current Alarm."
::= { psAlarmsGeneral1 11 }
psAlarmSubsystemOverCurrent NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Subsystem Over Current Alarm."
::= { psAlarmsGeneral1 12 }
psAlarmLVDsAreInhibited NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"LVDs Are Inhibited Alarm."
::= { psAlarmsGeneral1 13 }
psAlarmTestEqualizeMode NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Test/Equalize Mode Active."
::= { psAlarmsGeneral1 14 }
psAlarmMinor NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"System Minor Alarm."
::= { psAlarmsGeneral1 15 }
psAlarmMajor NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"System Major Alarm."
::= { psAlarmsGeneral1 16 }
psAlarmSenseVoltageFuse NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Sense Voltage Fuse Alarm."
::= { psAlarmsGeneral1 17 }
psAlarmSystemVoltageFuse NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"System Voltage Fuse Alarm."
::= { psAlarmsGeneral1 18 }
psAlarmNoSystemVoltage NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"No System Voltage Alarm."
::= { psAlarmsGeneral1 19 }
psAlarmNoSubsystemVoltage NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"No Subsystem Voltage Alarm."
::= { psAlarmsGeneral1 20 }
psAlarmNoSenseVoltage NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"No Sense Voltage Alarm."
::= { psAlarmsGeneral1 21 }
psAlarmDisplayNoReply NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Display Communications Alarm."
::= { psAlarmsGeneral1 22 }
psAlarmSubsystemMajor NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Subsystem Major Alarm."
::= { psAlarmsGeneral1 23 }
psAlarmSubsystemMinor NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Subsystem Minor Alarm."
::= { psAlarmsGeneral1 24 }
psAlarmHighACLine NOTIFICATION-TYPE
STATUS current
DESCRIPTION
" High AC Line Alarm."
::= { psAlarmsGeneral1 25 }
psAlarmSenseVoltageError NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Sense Voltage Error Alarm."
::= { psAlarmsGeneral1 26 }
psTestEqualizeHardwareInput NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"The MCA Test Equalize Hardware Input Active."
::= { psAlarmsGeneral2 1 }
psPCUFailMajor NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"PCU Fail Major Alarm."
::= { psAlarmsGeneral2 2 }
psPCUFailMinor NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"PCU Fail Minor Alarm."
::= { psAlarmsGeneral2 3 }
psLVDAlarmMajor NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"LVD Major Alarm."
::= { psAlarmsGeneral2 4 }
psLVDAlarmMinor NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"LVD Minor Alarm."
::= { psAlarmsGeneral2 5 }
psPCULoadShare NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"PCU Load Share Alarm."
::= { psAlarmsGeneral2 6 }
psACFailMajor NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"AC Fail Major Alarm."
::= { psAlarmsGeneral2 7 }
psACFailMinor NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"AC Fail Minor Alarm."
::= { psAlarmsGeneral2 8 }
psMCACommFail NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"MCA Communications Failure Alarm."
::= { psAlarmsGeneral2 9 }
psHVSActive NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"High Voltage Shutdown Active."
::= { psAlarmsGeneral2 10 }
psRemoteHVSActive NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Remote High Voltage Shutdown Active."
::= { psAlarmsGeneral2 11 }
psRemoteEstopActive NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Remote Emergency Stop Active."
::= { psAlarmsGeneral2 12 }
psAlarmBatteryChargeOverCurrent NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Battery Charge Over Current Alarm."
::= { psAlarmsBattery 1 }
psBatteryCurrentLimitInhibited NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Battery Current Limit Inhibited Alarm."
::= { psAlarmsBattery 2 }
psAlarmBatteryPoorHealth NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Battery Poor Health Alarm."
::= { psAlarmsBattery 3 }
psAlarmBatteryReserveLow NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Battery Reserve Low Alarm."
::= { psAlarmsBattery 4 }
psPCUSummaryTypeTraps OBJECT IDENTIFIER ::= { psTraps 4 }
psPCUSummaryTraps OBJECT IDENTIFIER ::= { psPCUSummaryTypeTraps 1 }
psAlarmPCUSummary NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"PCU Alarm Active."
::= { psPCUSummaryTraps 2 }
psPCUNodeTypeTraps OBJECT IDENTIFIER ::= { psTraps 5 }
psPCUTraps OBJECT IDENTIFIER ::= { psPCUNodeTypeTraps 1 }
psAlarmPCUId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"PCU Number."
::= { psPCUTraps 1 }
psAlarmPCUHighACLine NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"PCU High AC Line Alarm."
::= { psPCUTraps 2 }
psAlarmPCUControllerFailure NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"PCU Controller Failure Alarm."
::= { psPCUTraps 3 }
psAlarmPCUFanSlowOrStopped NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"PCU Fan Slow Or Stopped Alarm."
::= { psPCUTraps 4 }
psAlarmPCUTurnedOffByMca NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"PCU Turned Off By MCA."
::= { psPCUTraps 5 }
psAlarmPCUCircuitBreakerOff NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"PCU Circuit Breaker Off Alarm."
::= { psPCUTraps 6 }
psAlarmPCUDCorACConvertFail NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"PCU Converter Fail Alarm."
::= { psPCUTraps 7 }
psAlarmPCUThermalAlarmorCurrentLimit NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"PCU Thermal Current Limit Alarm."
::= { psPCUTraps 8 }
psAlarmPCUEmergencyStop NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"PCU Emergency Stop Alarm."
::= { psPCUTraps 9 }
psAlarmPCUInputSwitchOff NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"PCU Input Switch Off Alarm."
::= { psPCUTraps 10 }
psAlarmPCUHighVoltageShutdown NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"PCU High Voltage Shutdown Alarm."
::= { psPCUTraps 11 }
psAlarmPCUACInputIsOffOrLow NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"PCU AC Input Is Off Or Low Alarm."
::= { psPCUTraps 12 }
psAlarmPCUCommunicationFailureWithMCA NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"PCU Communication Failure Alarm."
::= { psPCUTraps 13 }
psAlarmPCUSenseLeadOpen NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"PCU Sense Lead Open Alarm."
::= { psPCUTraps 14 }
psShuntTypeTraps OBJECT IDENTIFIER ::= { psTraps 6 }
psShuntTraps OBJECT IDENTIFIER ::= { psShuntTypeTraps 1 }
psAlarmShuntId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Shunt POD Number."
::= { psShuntTraps 1 }
psAlarmShuntType NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Shunt POD Type Alarm."
::= { psShuntTraps 2 }
psAlarmShuntNoReply NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Shunt POD Communications Alarm."
::= { psShuntTraps 3 }
psLVDTypeTraps OBJECT IDENTIFIER ::= { psTraps 7 }
psLVDTraps OBJECT IDENTIFIER ::= { psLVDTypeTraps 1 }
psAlarmLVDId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Analog LVD Number "
::= { psLVDTraps 1 }
psAlarmLVDDisconnectedA NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"LVD Circuit A Disconnected Alarm."
::= { psLVDTraps 2 }
psAlarmLVDNoReplyA NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"LVD Circuit A Communications Alarm."
::= { psLVDTraps 3 }
psAlarmLVDBoardFailA NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"LVD Board Circuit A Fail Alarm."
::= { psLVDTraps 4 }
psAlarmLVDDisconnectedB NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"LVD Circuit B Disconnected Alarm."
::= { psLVDTraps 5 }
psAlarmLVDNoReplyB NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"LVD Circuit B No Communications Alarm."
::= { psLVDTraps 6 }
psAlarmLVDBoardFailB NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"LVD Board Circuit B Fail Alarm."
::= { psLVDTraps 7 }
psTemperatureTypeTraps OBJECT IDENTIFIER ::= { psTraps 8 }
psTemperatureTraps OBJECT IDENTIFIER ::= { psTemperatureTypeTraps 1 }
psAlarmTemperatureId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Temperature Probe Number."
::= { psTemperatureTraps 1 }
psAlarmTemperatureHigh NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Temperature High Alarm."
::= { psTemperatureTraps 2 }
psAlarmTemperatureLow NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Temperature Low Alarm."
::= { psTemperatureTraps 3 }
psAlarmTemperatureNoReply NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Temperature Communications Alarm."
::= { psTemperatureTraps 4 }
psSysInfoTypeTraps OBJECT IDENTIFIER ::= { psTraps 9 }
psSysInfoTraps OBJECT IDENTIFIER ::= { psSysInfoTypeTraps 1 }
psAlarmSysInfoError1 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"SysInfo Error 1."
::= { psSysInfoTraps 1 }
psAlarmSysInfoError2 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"SysInfo Error 2."
::= { psSysInfoTraps 2 }
psAlarmSysInfoString1 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"SysInfo String 1."
::= { psSysInfoTraps 3 }
psAlarmSysInfoString2 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"SysInfo String 2."
::= { psSysInfoTraps 4 }
psAlarmSysInfoString3 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"SysInfo String 3."
::= { psSysInfoTraps 5 }
psAlarmSysInfoString4 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"SysInfo String 4."
::= { psSysInfoTraps 6 }
psAlarmSysInfoString5 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"SysInfo String 5."
::= { psSysInfoTraps 7 }
psAlarmSysInfoString6 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"SysInfo String 6."
::= { psSysInfoTraps 8 }
psAlarmSysInfoString7 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"SysInfo String 7."
::= { psSysInfoTraps 9 }
psAlarmSysInfoString8 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"SysInfo String 8."
::= { psSysInfoTraps 10 }
psAlarmSysInfoString9 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"SysInfo String 9."
::= { psSysInfoTraps 11 }
psAlarmSysInfoString10 NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"SysInfo String 10."
::= { psSysInfoTraps 12 }