mirror of
https://github.com/librenms/librenms.git
synced 2024-09-22 10:58:42 +00:00
29bd6789cb
* STP module rewrite WIP * Finish rewrite * Ignore disabled and log root/topology changes * Remove interfaces for now * fix style * Lint fixes * Document ResolvesPortIds and hide map functions * whitespace fixes * Revert to stpInstances in case someone writes mstp support * missed one * phpstan fixes * Handle table and oids separately * forgot to register observer * Test data and correct non-table handling in SnmpResponse->table() * update test * test data * revert aos7 silly things * minimal polling * Update test data * order ports_ntp and rename new field to port_index * forgot the db_schema * revert ciena-sds port things * MSTP support, maybe * Adding test data * Filter bad lines instead of discarding the entire snmp response and capture fixes and test data * fresh data * add os data * update data, ignore unfound ports, obviously bad device implementation. * fixes * Ignore context files in os detection test * Remove empty table data * add ciena-sds vlan * designatedCost column is too small * Update stp webui * Refactor code to interfaces, to allow vendor mibs * update schema * fix issues added by abstraction * STP fixes * Default to no context for vlan 1 * never store vlan 1 * Update test data * remove eltex brokenness * fix style * fix stan * Fix Rewrite MAC to Hex padding with floats * fix sqlite migration
3203 lines
142 KiB
JSON
3203 lines
142 KiB
JSON
{
|
|
"os": {
|
|
"discovery": {
|
|
"devices": [
|
|
{
|
|
"sysName": "<private>",
|
|
"sysObjectID": ".1.3.6.1.4.1.4329.6.1.2.1.2",
|
|
"sysDescr": "Siemens, SIMATIC NET, SCALANCE XC206-2SFP, 6GK5 206-2BS00-2AC2, HW: Version 3, FW: Version V04.02.00, SVPM81xxxxx",
|
|
"sysContact": "<private>",
|
|
"version": "V04.02.00",
|
|
"hardware": "XC206-2SFP",
|
|
"features": "6GK5 206-2BS00-2AC2",
|
|
"os": "scalance",
|
|
"type": "network",
|
|
"serial": "VPM8190273",
|
|
"icon": "siemens.svg",
|
|
"location": "<private>"
|
|
}
|
|
]
|
|
},
|
|
"poller": "matches discovery"
|
|
},
|
|
"ports": {
|
|
"discovery": {
|
|
"ports": [
|
|
{
|
|
"port_descr_type": null,
|
|
"port_descr_descr": null,
|
|
"port_descr_circuit": null,
|
|
"port_descr_speed": null,
|
|
"port_descr_notes": null,
|
|
"ifDescr": "Siemens, SIMATIC NET, SCALANCE XC206-2SFP, 6GK5 206-2BS00-2AC2, HW: Version 3, FW: Version V04.02.00, SVPM81xxxxx, Ethernet Port, R0/S0/X1 P1",
|
|
"ifName": "P0.1",
|
|
"portName": null,
|
|
"ifIndex": 1,
|
|
"ifSpeed": null,
|
|
"ifSpeed_prev": null,
|
|
"ifConnectorPresent": null,
|
|
"ifPromiscuousMode": null,
|
|
"ifOperStatus": "down",
|
|
"ifOperStatus_prev": null,
|
|
"ifAdminStatus": null,
|
|
"ifAdminStatus_prev": null,
|
|
"ifDuplex": null,
|
|
"ifMtu": null,
|
|
"ifType": "ethernetCsmacd",
|
|
"ifAlias": "Siemens, SIMATIC NET, SCALANCE XC206-2SFP, 6GK5 206-2BS00-2AC2, HW: Version 3, FW: Version V04.02.00, SVPM81xxxxx, Ethernet Port, R0/S0/X1 P1",
|
|
"ifPhysAddress": null,
|
|
"ifHardType": null,
|
|
"ifLastChange": 0,
|
|
"ifVlan": "",
|
|
"ifTrunk": null,
|
|
"counter_in": null,
|
|
"counter_out": null,
|
|
"ignore": 0,
|
|
"disabled": 0,
|
|
"detailed": 0,
|
|
"deleted": 0,
|
|
"pagpOperationMode": null,
|
|
"pagpPortState": null,
|
|
"pagpPartnerDeviceId": null,
|
|
"pagpPartnerLearnMethod": null,
|
|
"pagpPartnerIfIndex": null,
|
|
"pagpPartnerGroupIfIndex": null,
|
|
"pagpPartnerDeviceName": null,
|
|
"pagpEthcOperationMode": null,
|
|
"pagpDeviceId": null,
|
|
"pagpGroupIfIndex": null,
|
|
"ifInUcastPkts": null,
|
|
"ifInUcastPkts_prev": null,
|
|
"ifInUcastPkts_delta": null,
|
|
"ifInUcastPkts_rate": null,
|
|
"ifOutUcastPkts": null,
|
|
"ifOutUcastPkts_prev": null,
|
|
"ifOutUcastPkts_delta": null,
|
|
"ifOutUcastPkts_rate": null,
|
|
"ifInErrors": null,
|
|
"ifInErrors_prev": null,
|
|
"ifInErrors_delta": null,
|
|
"ifInErrors_rate": null,
|
|
"ifOutErrors": null,
|
|
"ifOutErrors_prev": null,
|
|
"ifOutErrors_delta": null,
|
|
"ifOutErrors_rate": null,
|
|
"ifInOctets": null,
|
|
"ifInOctets_prev": null,
|
|
"ifInOctets_delta": null,
|
|
"ifInOctets_rate": null,
|
|
"ifOutOctets": null,
|
|
"ifOutOctets_prev": null,
|
|
"ifOutOctets_delta": null,
|
|
"ifOutOctets_rate": null,
|
|
"poll_prev": null,
|
|
"ifInNUcastPkts": null,
|
|
"ifInNUcastPkts_prev": null,
|
|
"ifInNUcastPkts_delta": null,
|
|
"ifInNUcastPkts_rate": null,
|
|
"ifOutNUcastPkts": null,
|
|
"ifOutNUcastPkts_prev": null,
|
|
"ifOutNUcastPkts_delta": null,
|
|
"ifOutNUcastPkts_rate": null,
|
|
"ifInDiscards": null,
|
|
"ifInDiscards_prev": null,
|
|
"ifInDiscards_delta": null,
|
|
"ifInDiscards_rate": null,
|
|
"ifOutDiscards": null,
|
|
"ifOutDiscards_prev": null,
|
|
"ifOutDiscards_delta": null,
|
|
"ifOutDiscards_rate": null,
|
|
"ifInUnknownProtos": null,
|
|
"ifInUnknownProtos_prev": null,
|
|
"ifInUnknownProtos_delta": null,
|
|
"ifInUnknownProtos_rate": null,
|
|
"ifInBroadcastPkts": null,
|
|
"ifInBroadcastPkts_prev": null,
|
|
"ifInBroadcastPkts_delta": null,
|
|
"ifInBroadcastPkts_rate": null,
|
|
"ifOutBroadcastPkts": null,
|
|
"ifOutBroadcastPkts_prev": null,
|
|
"ifOutBroadcastPkts_delta": null,
|
|
"ifOutBroadcastPkts_rate": null,
|
|
"ifInMulticastPkts": null,
|
|
"ifInMulticastPkts_prev": null,
|
|
"ifInMulticastPkts_delta": null,
|
|
"ifInMulticastPkts_rate": null,
|
|
"ifOutMulticastPkts": null,
|
|
"ifOutMulticastPkts_prev": null,
|
|
"ifOutMulticastPkts_delta": null,
|
|
"ifOutMulticastPkts_rate": null
|
|
},
|
|
{
|
|
"port_descr_type": null,
|
|
"port_descr_descr": null,
|
|
"port_descr_circuit": null,
|
|
"port_descr_speed": null,
|
|
"port_descr_notes": null,
|
|
"ifDescr": "Siemens, SIMATIC NET, SCALANCE XC206-2SFP, 6GK5 206-2BS00-2AC2, HW: Version 3, FW: Version V04.02.00, SVPM81xxxxx, Ethernet Port, R0/S0/X1 P2",
|
|
"ifName": "P0.2",
|
|
"portName": null,
|
|
"ifIndex": 2,
|
|
"ifSpeed": null,
|
|
"ifSpeed_prev": null,
|
|
"ifConnectorPresent": null,
|
|
"ifPromiscuousMode": null,
|
|
"ifOperStatus": "down",
|
|
"ifOperStatus_prev": null,
|
|
"ifAdminStatus": null,
|
|
"ifAdminStatus_prev": null,
|
|
"ifDuplex": null,
|
|
"ifMtu": null,
|
|
"ifType": "ethernetCsmacd",
|
|
"ifAlias": "Siemens, SIMATIC NET, SCALANCE XC206-2SFP, 6GK5 206-2BS00-2AC2, HW: Version 3, FW: Version V04.02.00, SVPM81xxxxx, Ethernet Port, R0/S0/X1 P2",
|
|
"ifPhysAddress": null,
|
|
"ifHardType": null,
|
|
"ifLastChange": 0,
|
|
"ifVlan": "",
|
|
"ifTrunk": null,
|
|
"counter_in": null,
|
|
"counter_out": null,
|
|
"ignore": 0,
|
|
"disabled": 0,
|
|
"detailed": 0,
|
|
"deleted": 0,
|
|
"pagpOperationMode": null,
|
|
"pagpPortState": null,
|
|
"pagpPartnerDeviceId": null,
|
|
"pagpPartnerLearnMethod": null,
|
|
"pagpPartnerIfIndex": null,
|
|
"pagpPartnerGroupIfIndex": null,
|
|
"pagpPartnerDeviceName": null,
|
|
"pagpEthcOperationMode": null,
|
|
"pagpDeviceId": null,
|
|
"pagpGroupIfIndex": null,
|
|
"ifInUcastPkts": null,
|
|
"ifInUcastPkts_prev": null,
|
|
"ifInUcastPkts_delta": null,
|
|
"ifInUcastPkts_rate": null,
|
|
"ifOutUcastPkts": null,
|
|
"ifOutUcastPkts_prev": null,
|
|
"ifOutUcastPkts_delta": null,
|
|
"ifOutUcastPkts_rate": null,
|
|
"ifInErrors": null,
|
|
"ifInErrors_prev": null,
|
|
"ifInErrors_delta": null,
|
|
"ifInErrors_rate": null,
|
|
"ifOutErrors": null,
|
|
"ifOutErrors_prev": null,
|
|
"ifOutErrors_delta": null,
|
|
"ifOutErrors_rate": null,
|
|
"ifInOctets": null,
|
|
"ifInOctets_prev": null,
|
|
"ifInOctets_delta": null,
|
|
"ifInOctets_rate": null,
|
|
"ifOutOctets": null,
|
|
"ifOutOctets_prev": null,
|
|
"ifOutOctets_delta": null,
|
|
"ifOutOctets_rate": null,
|
|
"poll_prev": null,
|
|
"ifInNUcastPkts": null,
|
|
"ifInNUcastPkts_prev": null,
|
|
"ifInNUcastPkts_delta": null,
|
|
"ifInNUcastPkts_rate": null,
|
|
"ifOutNUcastPkts": null,
|
|
"ifOutNUcastPkts_prev": null,
|
|
"ifOutNUcastPkts_delta": null,
|
|
"ifOutNUcastPkts_rate": null,
|
|
"ifInDiscards": null,
|
|
"ifInDiscards_prev": null,
|
|
"ifInDiscards_delta": null,
|
|
"ifInDiscards_rate": null,
|
|
"ifOutDiscards": null,
|
|
"ifOutDiscards_prev": null,
|
|
"ifOutDiscards_delta": null,
|
|
"ifOutDiscards_rate": null,
|
|
"ifInUnknownProtos": null,
|
|
"ifInUnknownProtos_prev": null,
|
|
"ifInUnknownProtos_delta": null,
|
|
"ifInUnknownProtos_rate": null,
|
|
"ifInBroadcastPkts": null,
|
|
"ifInBroadcastPkts_prev": null,
|
|
"ifInBroadcastPkts_delta": null,
|
|
"ifInBroadcastPkts_rate": null,
|
|
"ifOutBroadcastPkts": null,
|
|
"ifOutBroadcastPkts_prev": null,
|
|
"ifOutBroadcastPkts_delta": null,
|
|
"ifOutBroadcastPkts_rate": null,
|
|
"ifInMulticastPkts": null,
|
|
"ifInMulticastPkts_prev": null,
|
|
"ifInMulticastPkts_delta": null,
|
|
"ifInMulticastPkts_rate": null,
|
|
"ifOutMulticastPkts": null,
|
|
"ifOutMulticastPkts_prev": null,
|
|
"ifOutMulticastPkts_delta": null,
|
|
"ifOutMulticastPkts_rate": null
|
|
},
|
|
{
|
|
"port_descr_type": null,
|
|
"port_descr_descr": null,
|
|
"port_descr_circuit": null,
|
|
"port_descr_speed": null,
|
|
"port_descr_notes": null,
|
|
"ifDescr": "Siemens, SIMATIC NET, SCALANCE XC206-2SFP, 6GK5 206-2BS00-2AC2, HW: Version 3, FW: Version V04.02.00, SVPM81xxxxx, Ethernet Port, R0/S0/X1 P3",
|
|
"ifName": "P0.3",
|
|
"portName": null,
|
|
"ifIndex": 3,
|
|
"ifSpeed": null,
|
|
"ifSpeed_prev": null,
|
|
"ifConnectorPresent": null,
|
|
"ifPromiscuousMode": null,
|
|
"ifOperStatus": "down",
|
|
"ifOperStatus_prev": null,
|
|
"ifAdminStatus": null,
|
|
"ifAdminStatus_prev": null,
|
|
"ifDuplex": null,
|
|
"ifMtu": null,
|
|
"ifType": "ethernetCsmacd",
|
|
"ifAlias": "Siemens, SIMATIC NET, SCALANCE XC206-2SFP, 6GK5 206-2BS00-2AC2, HW: Version 3, FW: Version V04.02.00, SVPM81xxxxx, Ethernet Port, R0/S0/X1 P3",
|
|
"ifPhysAddress": null,
|
|
"ifHardType": null,
|
|
"ifLastChange": 0,
|
|
"ifVlan": "",
|
|
"ifTrunk": null,
|
|
"counter_in": null,
|
|
"counter_out": null,
|
|
"ignore": 0,
|
|
"disabled": 0,
|
|
"detailed": 0,
|
|
"deleted": 0,
|
|
"pagpOperationMode": null,
|
|
"pagpPortState": null,
|
|
"pagpPartnerDeviceId": null,
|
|
"pagpPartnerLearnMethod": null,
|
|
"pagpPartnerIfIndex": null,
|
|
"pagpPartnerGroupIfIndex": null,
|
|
"pagpPartnerDeviceName": null,
|
|
"pagpEthcOperationMode": null,
|
|
"pagpDeviceId": null,
|
|
"pagpGroupIfIndex": null,
|
|
"ifInUcastPkts": null,
|
|
"ifInUcastPkts_prev": null,
|
|
"ifInUcastPkts_delta": null,
|
|
"ifInUcastPkts_rate": null,
|
|
"ifOutUcastPkts": null,
|
|
"ifOutUcastPkts_prev": null,
|
|
"ifOutUcastPkts_delta": null,
|
|
"ifOutUcastPkts_rate": null,
|
|
"ifInErrors": null,
|
|
"ifInErrors_prev": null,
|
|
"ifInErrors_delta": null,
|
|
"ifInErrors_rate": null,
|
|
"ifOutErrors": null,
|
|
"ifOutErrors_prev": null,
|
|
"ifOutErrors_delta": null,
|
|
"ifOutErrors_rate": null,
|
|
"ifInOctets": null,
|
|
"ifInOctets_prev": null,
|
|
"ifInOctets_delta": null,
|
|
"ifInOctets_rate": null,
|
|
"ifOutOctets": null,
|
|
"ifOutOctets_prev": null,
|
|
"ifOutOctets_delta": null,
|
|
"ifOutOctets_rate": null,
|
|
"poll_prev": null,
|
|
"ifInNUcastPkts": null,
|
|
"ifInNUcastPkts_prev": null,
|
|
"ifInNUcastPkts_delta": null,
|
|
"ifInNUcastPkts_rate": null,
|
|
"ifOutNUcastPkts": null,
|
|
"ifOutNUcastPkts_prev": null,
|
|
"ifOutNUcastPkts_delta": null,
|
|
"ifOutNUcastPkts_rate": null,
|
|
"ifInDiscards": null,
|
|
"ifInDiscards_prev": null,
|
|
"ifInDiscards_delta": null,
|
|
"ifInDiscards_rate": null,
|
|
"ifOutDiscards": null,
|
|
"ifOutDiscards_prev": null,
|
|
"ifOutDiscards_delta": null,
|
|
"ifOutDiscards_rate": null,
|
|
"ifInUnknownProtos": null,
|
|
"ifInUnknownProtos_prev": null,
|
|
"ifInUnknownProtos_delta": null,
|
|
"ifInUnknownProtos_rate": null,
|
|
"ifInBroadcastPkts": null,
|
|
"ifInBroadcastPkts_prev": null,
|
|
"ifInBroadcastPkts_delta": null,
|
|
"ifInBroadcastPkts_rate": null,
|
|
"ifOutBroadcastPkts": null,
|
|
"ifOutBroadcastPkts_prev": null,
|
|
"ifOutBroadcastPkts_delta": null,
|
|
"ifOutBroadcastPkts_rate": null,
|
|
"ifInMulticastPkts": null,
|
|
"ifInMulticastPkts_prev": null,
|
|
"ifInMulticastPkts_delta": null,
|
|
"ifInMulticastPkts_rate": null,
|
|
"ifOutMulticastPkts": null,
|
|
"ifOutMulticastPkts_prev": null,
|
|
"ifOutMulticastPkts_delta": null,
|
|
"ifOutMulticastPkts_rate": null
|
|
},
|
|
{
|
|
"port_descr_type": null,
|
|
"port_descr_descr": null,
|
|
"port_descr_circuit": null,
|
|
"port_descr_speed": null,
|
|
"port_descr_notes": null,
|
|
"ifDescr": "Siemens, SIMATIC NET, SCALANCE XC206-2SFP, 6GK5 206-2BS00-2AC2, HW: Version 3, FW: Version V04.02.00, SVPM81xxxxx, Ethernet Port, R0/S0/X1 P4",
|
|
"ifName": "P0.4",
|
|
"portName": null,
|
|
"ifIndex": 4,
|
|
"ifSpeed": null,
|
|
"ifSpeed_prev": null,
|
|
"ifConnectorPresent": null,
|
|
"ifPromiscuousMode": null,
|
|
"ifOperStatus": "down",
|
|
"ifOperStatus_prev": null,
|
|
"ifAdminStatus": null,
|
|
"ifAdminStatus_prev": null,
|
|
"ifDuplex": null,
|
|
"ifMtu": null,
|
|
"ifType": "ethernetCsmacd",
|
|
"ifAlias": "Siemens, SIMATIC NET, SCALANCE XC206-2SFP, 6GK5 206-2BS00-2AC2, HW: Version 3, FW: Version V04.02.00, SVPM81xxxxx, Ethernet Port, R0/S0/X1 P4",
|
|
"ifPhysAddress": null,
|
|
"ifHardType": null,
|
|
"ifLastChange": 0,
|
|
"ifVlan": "",
|
|
"ifTrunk": null,
|
|
"counter_in": null,
|
|
"counter_out": null,
|
|
"ignore": 0,
|
|
"disabled": 0,
|
|
"detailed": 0,
|
|
"deleted": 0,
|
|
"pagpOperationMode": null,
|
|
"pagpPortState": null,
|
|
"pagpPartnerDeviceId": null,
|
|
"pagpPartnerLearnMethod": null,
|
|
"pagpPartnerIfIndex": null,
|
|
"pagpPartnerGroupIfIndex": null,
|
|
"pagpPartnerDeviceName": null,
|
|
"pagpEthcOperationMode": null,
|
|
"pagpDeviceId": null,
|
|
"pagpGroupIfIndex": null,
|
|
"ifInUcastPkts": null,
|
|
"ifInUcastPkts_prev": null,
|
|
"ifInUcastPkts_delta": null,
|
|
"ifInUcastPkts_rate": null,
|
|
"ifOutUcastPkts": null,
|
|
"ifOutUcastPkts_prev": null,
|
|
"ifOutUcastPkts_delta": null,
|
|
"ifOutUcastPkts_rate": null,
|
|
"ifInErrors": null,
|
|
"ifInErrors_prev": null,
|
|
"ifInErrors_delta": null,
|
|
"ifInErrors_rate": null,
|
|
"ifOutErrors": null,
|
|
"ifOutErrors_prev": null,
|
|
"ifOutErrors_delta": null,
|
|
"ifOutErrors_rate": null,
|
|
"ifInOctets": null,
|
|
"ifInOctets_prev": null,
|
|
"ifInOctets_delta": null,
|
|
"ifInOctets_rate": null,
|
|
"ifOutOctets": null,
|
|
"ifOutOctets_prev": null,
|
|
"ifOutOctets_delta": null,
|
|
"ifOutOctets_rate": null,
|
|
"poll_prev": null,
|
|
"ifInNUcastPkts": null,
|
|
"ifInNUcastPkts_prev": null,
|
|
"ifInNUcastPkts_delta": null,
|
|
"ifInNUcastPkts_rate": null,
|
|
"ifOutNUcastPkts": null,
|
|
"ifOutNUcastPkts_prev": null,
|
|
"ifOutNUcastPkts_delta": null,
|
|
"ifOutNUcastPkts_rate": null,
|
|
"ifInDiscards": null,
|
|
"ifInDiscards_prev": null,
|
|
"ifInDiscards_delta": null,
|
|
"ifInDiscards_rate": null,
|
|
"ifOutDiscards": null,
|
|
"ifOutDiscards_prev": null,
|
|
"ifOutDiscards_delta": null,
|
|
"ifOutDiscards_rate": null,
|
|
"ifInUnknownProtos": null,
|
|
"ifInUnknownProtos_prev": null,
|
|
"ifInUnknownProtos_delta": null,
|
|
"ifInUnknownProtos_rate": null,
|
|
"ifInBroadcastPkts": null,
|
|
"ifInBroadcastPkts_prev": null,
|
|
"ifInBroadcastPkts_delta": null,
|
|
"ifInBroadcastPkts_rate": null,
|
|
"ifOutBroadcastPkts": null,
|
|
"ifOutBroadcastPkts_prev": null,
|
|
"ifOutBroadcastPkts_delta": null,
|
|
"ifOutBroadcastPkts_rate": null,
|
|
"ifInMulticastPkts": null,
|
|
"ifInMulticastPkts_prev": null,
|
|
"ifInMulticastPkts_delta": null,
|
|
"ifInMulticastPkts_rate": null,
|
|
"ifOutMulticastPkts": null,
|
|
"ifOutMulticastPkts_prev": null,
|
|
"ifOutMulticastPkts_delta": null,
|
|
"ifOutMulticastPkts_rate": null
|
|
},
|
|
{
|
|
"port_descr_type": null,
|
|
"port_descr_descr": null,
|
|
"port_descr_circuit": null,
|
|
"port_descr_speed": null,
|
|
"port_descr_notes": null,
|
|
"ifDescr": "Siemens, SIMATIC NET, SCALANCE XC206-2SFP, 6GK5 206-2BS00-2AC2, HW: Version 3, FW: Version V04.02.00, SVPM81xxxxx, Ethernet Port, R0/S0/X1 P5",
|
|
"ifName": "P0.5",
|
|
"portName": null,
|
|
"ifIndex": 5,
|
|
"ifSpeed": null,
|
|
"ifSpeed_prev": null,
|
|
"ifConnectorPresent": null,
|
|
"ifPromiscuousMode": null,
|
|
"ifOperStatus": "down",
|
|
"ifOperStatus_prev": null,
|
|
"ifAdminStatus": null,
|
|
"ifAdminStatus_prev": null,
|
|
"ifDuplex": null,
|
|
"ifMtu": null,
|
|
"ifType": "ethernetCsmacd",
|
|
"ifAlias": "Siemens, SIMATIC NET, SCALANCE XC206-2SFP, 6GK5 206-2BS00-2AC2, HW: Version 3, FW: Version V04.02.00, SVPM81xxxxx, Ethernet Port, R0/S0/X1 P5",
|
|
"ifPhysAddress": null,
|
|
"ifHardType": null,
|
|
"ifLastChange": 0,
|
|
"ifVlan": "",
|
|
"ifTrunk": null,
|
|
"counter_in": null,
|
|
"counter_out": null,
|
|
"ignore": 0,
|
|
"disabled": 0,
|
|
"detailed": 0,
|
|
"deleted": 0,
|
|
"pagpOperationMode": null,
|
|
"pagpPortState": null,
|
|
"pagpPartnerDeviceId": null,
|
|
"pagpPartnerLearnMethod": null,
|
|
"pagpPartnerIfIndex": null,
|
|
"pagpPartnerGroupIfIndex": null,
|
|
"pagpPartnerDeviceName": null,
|
|
"pagpEthcOperationMode": null,
|
|
"pagpDeviceId": null,
|
|
"pagpGroupIfIndex": null,
|
|
"ifInUcastPkts": null,
|
|
"ifInUcastPkts_prev": null,
|
|
"ifInUcastPkts_delta": null,
|
|
"ifInUcastPkts_rate": null,
|
|
"ifOutUcastPkts": null,
|
|
"ifOutUcastPkts_prev": null,
|
|
"ifOutUcastPkts_delta": null,
|
|
"ifOutUcastPkts_rate": null,
|
|
"ifInErrors": null,
|
|
"ifInErrors_prev": null,
|
|
"ifInErrors_delta": null,
|
|
"ifInErrors_rate": null,
|
|
"ifOutErrors": null,
|
|
"ifOutErrors_prev": null,
|
|
"ifOutErrors_delta": null,
|
|
"ifOutErrors_rate": null,
|
|
"ifInOctets": null,
|
|
"ifInOctets_prev": null,
|
|
"ifInOctets_delta": null,
|
|
"ifInOctets_rate": null,
|
|
"ifOutOctets": null,
|
|
"ifOutOctets_prev": null,
|
|
"ifOutOctets_delta": null,
|
|
"ifOutOctets_rate": null,
|
|
"poll_prev": null,
|
|
"ifInNUcastPkts": null,
|
|
"ifInNUcastPkts_prev": null,
|
|
"ifInNUcastPkts_delta": null,
|
|
"ifInNUcastPkts_rate": null,
|
|
"ifOutNUcastPkts": null,
|
|
"ifOutNUcastPkts_prev": null,
|
|
"ifOutNUcastPkts_delta": null,
|
|
"ifOutNUcastPkts_rate": null,
|
|
"ifInDiscards": null,
|
|
"ifInDiscards_prev": null,
|
|
"ifInDiscards_delta": null,
|
|
"ifInDiscards_rate": null,
|
|
"ifOutDiscards": null,
|
|
"ifOutDiscards_prev": null,
|
|
"ifOutDiscards_delta": null,
|
|
"ifOutDiscards_rate": null,
|
|
"ifInUnknownProtos": null,
|
|
"ifInUnknownProtos_prev": null,
|
|
"ifInUnknownProtos_delta": null,
|
|
"ifInUnknownProtos_rate": null,
|
|
"ifInBroadcastPkts": null,
|
|
"ifInBroadcastPkts_prev": null,
|
|
"ifInBroadcastPkts_delta": null,
|
|
"ifInBroadcastPkts_rate": null,
|
|
"ifOutBroadcastPkts": null,
|
|
"ifOutBroadcastPkts_prev": null,
|
|
"ifOutBroadcastPkts_delta": null,
|
|
"ifOutBroadcastPkts_rate": null,
|
|
"ifInMulticastPkts": null,
|
|
"ifInMulticastPkts_prev": null,
|
|
"ifInMulticastPkts_delta": null,
|
|
"ifInMulticastPkts_rate": null,
|
|
"ifOutMulticastPkts": null,
|
|
"ifOutMulticastPkts_prev": null,
|
|
"ifOutMulticastPkts_delta": null,
|
|
"ifOutMulticastPkts_rate": null
|
|
},
|
|
{
|
|
"port_descr_type": null,
|
|
"port_descr_descr": null,
|
|
"port_descr_circuit": null,
|
|
"port_descr_speed": null,
|
|
"port_descr_notes": null,
|
|
"ifDescr": "Siemens, SIMATIC NET, SCALANCE XC206-2SFP, 6GK5 206-2BS00-2AC2, HW: Version 3, FW: Version V04.02.00, SVPM81xxxxx, Ethernet Port, R0/S0/X1 P6",
|
|
"ifName": "P0.6",
|
|
"portName": null,
|
|
"ifIndex": 6,
|
|
"ifSpeed": null,
|
|
"ifSpeed_prev": null,
|
|
"ifConnectorPresent": null,
|
|
"ifPromiscuousMode": null,
|
|
"ifOperStatus": "down",
|
|
"ifOperStatus_prev": null,
|
|
"ifAdminStatus": null,
|
|
"ifAdminStatus_prev": null,
|
|
"ifDuplex": null,
|
|
"ifMtu": null,
|
|
"ifType": "ethernetCsmacd",
|
|
"ifAlias": "Siemens, SIMATIC NET, SCALANCE XC206-2SFP, 6GK5 206-2BS00-2AC2, HW: Version 3, FW: Version V04.02.00, SVPM81xxxxx, Ethernet Port, R0/S0/X1 P6",
|
|
"ifPhysAddress": null,
|
|
"ifHardType": null,
|
|
"ifLastChange": 0,
|
|
"ifVlan": "",
|
|
"ifTrunk": null,
|
|
"counter_in": null,
|
|
"counter_out": null,
|
|
"ignore": 0,
|
|
"disabled": 0,
|
|
"detailed": 0,
|
|
"deleted": 0,
|
|
"pagpOperationMode": null,
|
|
"pagpPortState": null,
|
|
"pagpPartnerDeviceId": null,
|
|
"pagpPartnerLearnMethod": null,
|
|
"pagpPartnerIfIndex": null,
|
|
"pagpPartnerGroupIfIndex": null,
|
|
"pagpPartnerDeviceName": null,
|
|
"pagpEthcOperationMode": null,
|
|
"pagpDeviceId": null,
|
|
"pagpGroupIfIndex": null,
|
|
"ifInUcastPkts": null,
|
|
"ifInUcastPkts_prev": null,
|
|
"ifInUcastPkts_delta": null,
|
|
"ifInUcastPkts_rate": null,
|
|
"ifOutUcastPkts": null,
|
|
"ifOutUcastPkts_prev": null,
|
|
"ifOutUcastPkts_delta": null,
|
|
"ifOutUcastPkts_rate": null,
|
|
"ifInErrors": null,
|
|
"ifInErrors_prev": null,
|
|
"ifInErrors_delta": null,
|
|
"ifInErrors_rate": null,
|
|
"ifOutErrors": null,
|
|
"ifOutErrors_prev": null,
|
|
"ifOutErrors_delta": null,
|
|
"ifOutErrors_rate": null,
|
|
"ifInOctets": null,
|
|
"ifInOctets_prev": null,
|
|
"ifInOctets_delta": null,
|
|
"ifInOctets_rate": null,
|
|
"ifOutOctets": null,
|
|
"ifOutOctets_prev": null,
|
|
"ifOutOctets_delta": null,
|
|
"ifOutOctets_rate": null,
|
|
"poll_prev": null,
|
|
"ifInNUcastPkts": null,
|
|
"ifInNUcastPkts_prev": null,
|
|
"ifInNUcastPkts_delta": null,
|
|
"ifInNUcastPkts_rate": null,
|
|
"ifOutNUcastPkts": null,
|
|
"ifOutNUcastPkts_prev": null,
|
|
"ifOutNUcastPkts_delta": null,
|
|
"ifOutNUcastPkts_rate": null,
|
|
"ifInDiscards": null,
|
|
"ifInDiscards_prev": null,
|
|
"ifInDiscards_delta": null,
|
|
"ifInDiscards_rate": null,
|
|
"ifOutDiscards": null,
|
|
"ifOutDiscards_prev": null,
|
|
"ifOutDiscards_delta": null,
|
|
"ifOutDiscards_rate": null,
|
|
"ifInUnknownProtos": null,
|
|
"ifInUnknownProtos_prev": null,
|
|
"ifInUnknownProtos_delta": null,
|
|
"ifInUnknownProtos_rate": null,
|
|
"ifInBroadcastPkts": null,
|
|
"ifInBroadcastPkts_prev": null,
|
|
"ifInBroadcastPkts_delta": null,
|
|
"ifInBroadcastPkts_rate": null,
|
|
"ifOutBroadcastPkts": null,
|
|
"ifOutBroadcastPkts_prev": null,
|
|
"ifOutBroadcastPkts_delta": null,
|
|
"ifOutBroadcastPkts_rate": null,
|
|
"ifInMulticastPkts": null,
|
|
"ifInMulticastPkts_prev": null,
|
|
"ifInMulticastPkts_delta": null,
|
|
"ifInMulticastPkts_rate": null,
|
|
"ifOutMulticastPkts": null,
|
|
"ifOutMulticastPkts_prev": null,
|
|
"ifOutMulticastPkts_delta": null,
|
|
"ifOutMulticastPkts_rate": null
|
|
},
|
|
{
|
|
"port_descr_type": null,
|
|
"port_descr_descr": null,
|
|
"port_descr_circuit": null,
|
|
"port_descr_speed": null,
|
|
"port_descr_notes": null,
|
|
"ifDescr": "Siemens, SIMATIC NET, 3rd Party SFP opt. 1 GBit/s, -, HW: Version A0, FW: Version -, S-, Ethernet Port, R0/S0/X1 P7",
|
|
"ifName": "P0.7",
|
|
"portName": null,
|
|
"ifIndex": 7,
|
|
"ifSpeed": null,
|
|
"ifSpeed_prev": null,
|
|
"ifConnectorPresent": null,
|
|
"ifPromiscuousMode": null,
|
|
"ifOperStatus": "down",
|
|
"ifOperStatus_prev": null,
|
|
"ifAdminStatus": null,
|
|
"ifAdminStatus_prev": null,
|
|
"ifDuplex": null,
|
|
"ifMtu": null,
|
|
"ifType": "ethernetCsmacd",
|
|
"ifAlias": "Siemens, SIMATIC NET, 3rd Party SFP opt. 1 GBit/s, -, HW: Version A0, FW: Version -, S-, Ethernet Port, R0/S0/X1 P7",
|
|
"ifPhysAddress": null,
|
|
"ifHardType": null,
|
|
"ifLastChange": 0,
|
|
"ifVlan": "",
|
|
"ifTrunk": null,
|
|
"counter_in": null,
|
|
"counter_out": null,
|
|
"ignore": 0,
|
|
"disabled": 0,
|
|
"detailed": 0,
|
|
"deleted": 0,
|
|
"pagpOperationMode": null,
|
|
"pagpPortState": null,
|
|
"pagpPartnerDeviceId": null,
|
|
"pagpPartnerLearnMethod": null,
|
|
"pagpPartnerIfIndex": null,
|
|
"pagpPartnerGroupIfIndex": null,
|
|
"pagpPartnerDeviceName": null,
|
|
"pagpEthcOperationMode": null,
|
|
"pagpDeviceId": null,
|
|
"pagpGroupIfIndex": null,
|
|
"ifInUcastPkts": null,
|
|
"ifInUcastPkts_prev": null,
|
|
"ifInUcastPkts_delta": null,
|
|
"ifInUcastPkts_rate": null,
|
|
"ifOutUcastPkts": null,
|
|
"ifOutUcastPkts_prev": null,
|
|
"ifOutUcastPkts_delta": null,
|
|
"ifOutUcastPkts_rate": null,
|
|
"ifInErrors": null,
|
|
"ifInErrors_prev": null,
|
|
"ifInErrors_delta": null,
|
|
"ifInErrors_rate": null,
|
|
"ifOutErrors": null,
|
|
"ifOutErrors_prev": null,
|
|
"ifOutErrors_delta": null,
|
|
"ifOutErrors_rate": null,
|
|
"ifInOctets": null,
|
|
"ifInOctets_prev": null,
|
|
"ifInOctets_delta": null,
|
|
"ifInOctets_rate": null,
|
|
"ifOutOctets": null,
|
|
"ifOutOctets_prev": null,
|
|
"ifOutOctets_delta": null,
|
|
"ifOutOctets_rate": null,
|
|
"poll_prev": null,
|
|
"ifInNUcastPkts": null,
|
|
"ifInNUcastPkts_prev": null,
|
|
"ifInNUcastPkts_delta": null,
|
|
"ifInNUcastPkts_rate": null,
|
|
"ifOutNUcastPkts": null,
|
|
"ifOutNUcastPkts_prev": null,
|
|
"ifOutNUcastPkts_delta": null,
|
|
"ifOutNUcastPkts_rate": null,
|
|
"ifInDiscards": null,
|
|
"ifInDiscards_prev": null,
|
|
"ifInDiscards_delta": null,
|
|
"ifInDiscards_rate": null,
|
|
"ifOutDiscards": null,
|
|
"ifOutDiscards_prev": null,
|
|
"ifOutDiscards_delta": null,
|
|
"ifOutDiscards_rate": null,
|
|
"ifInUnknownProtos": null,
|
|
"ifInUnknownProtos_prev": null,
|
|
"ifInUnknownProtos_delta": null,
|
|
"ifInUnknownProtos_rate": null,
|
|
"ifInBroadcastPkts": null,
|
|
"ifInBroadcastPkts_prev": null,
|
|
"ifInBroadcastPkts_delta": null,
|
|
"ifInBroadcastPkts_rate": null,
|
|
"ifOutBroadcastPkts": null,
|
|
"ifOutBroadcastPkts_prev": null,
|
|
"ifOutBroadcastPkts_delta": null,
|
|
"ifOutBroadcastPkts_rate": null,
|
|
"ifInMulticastPkts": null,
|
|
"ifInMulticastPkts_prev": null,
|
|
"ifInMulticastPkts_delta": null,
|
|
"ifInMulticastPkts_rate": null,
|
|
"ifOutMulticastPkts": null,
|
|
"ifOutMulticastPkts_prev": null,
|
|
"ifOutMulticastPkts_delta": null,
|
|
"ifOutMulticastPkts_rate": null
|
|
},
|
|
{
|
|
"port_descr_type": null,
|
|
"port_descr_descr": null,
|
|
"port_descr_circuit": null,
|
|
"port_descr_speed": null,
|
|
"port_descr_notes": null,
|
|
"ifDescr": "Siemens, SIMATIC NET, SFP992-1LD, 6GK5 992-1AM00-8AA0, HW: Version 2, FW: Version -, S-, Ethernet Port, R0/S0/X1 P8",
|
|
"ifName": "P0.8",
|
|
"portName": null,
|
|
"ifIndex": 8,
|
|
"ifSpeed": null,
|
|
"ifSpeed_prev": null,
|
|
"ifConnectorPresent": null,
|
|
"ifPromiscuousMode": null,
|
|
"ifOperStatus": "up",
|
|
"ifOperStatus_prev": null,
|
|
"ifAdminStatus": null,
|
|
"ifAdminStatus_prev": null,
|
|
"ifDuplex": null,
|
|
"ifMtu": null,
|
|
"ifType": "ethernetCsmacd",
|
|
"ifAlias": "Siemens, SIMATIC NET, SFP992-1LD, 6GK5 992-1AM00-8AA0, HW: Version 2, FW: Version -, S-, Ethernet Port, R0/S0/X1 P8",
|
|
"ifPhysAddress": null,
|
|
"ifHardType": null,
|
|
"ifLastChange": 0,
|
|
"ifVlan": "",
|
|
"ifTrunk": null,
|
|
"counter_in": null,
|
|
"counter_out": null,
|
|
"ignore": 0,
|
|
"disabled": 0,
|
|
"detailed": 0,
|
|
"deleted": 0,
|
|
"pagpOperationMode": null,
|
|
"pagpPortState": null,
|
|
"pagpPartnerDeviceId": null,
|
|
"pagpPartnerLearnMethod": null,
|
|
"pagpPartnerIfIndex": null,
|
|
"pagpPartnerGroupIfIndex": null,
|
|
"pagpPartnerDeviceName": null,
|
|
"pagpEthcOperationMode": null,
|
|
"pagpDeviceId": null,
|
|
"pagpGroupIfIndex": null,
|
|
"ifInUcastPkts": null,
|
|
"ifInUcastPkts_prev": null,
|
|
"ifInUcastPkts_delta": null,
|
|
"ifInUcastPkts_rate": null,
|
|
"ifOutUcastPkts": null,
|
|
"ifOutUcastPkts_prev": null,
|
|
"ifOutUcastPkts_delta": null,
|
|
"ifOutUcastPkts_rate": null,
|
|
"ifInErrors": null,
|
|
"ifInErrors_prev": null,
|
|
"ifInErrors_delta": null,
|
|
"ifInErrors_rate": null,
|
|
"ifOutErrors": null,
|
|
"ifOutErrors_prev": null,
|
|
"ifOutErrors_delta": null,
|
|
"ifOutErrors_rate": null,
|
|
"ifInOctets": null,
|
|
"ifInOctets_prev": null,
|
|
"ifInOctets_delta": null,
|
|
"ifInOctets_rate": null,
|
|
"ifOutOctets": null,
|
|
"ifOutOctets_prev": null,
|
|
"ifOutOctets_delta": null,
|
|
"ifOutOctets_rate": null,
|
|
"poll_prev": null,
|
|
"ifInNUcastPkts": null,
|
|
"ifInNUcastPkts_prev": null,
|
|
"ifInNUcastPkts_delta": null,
|
|
"ifInNUcastPkts_rate": null,
|
|
"ifOutNUcastPkts": null,
|
|
"ifOutNUcastPkts_prev": null,
|
|
"ifOutNUcastPkts_delta": null,
|
|
"ifOutNUcastPkts_rate": null,
|
|
"ifInDiscards": null,
|
|
"ifInDiscards_prev": null,
|
|
"ifInDiscards_delta": null,
|
|
"ifInDiscards_rate": null,
|
|
"ifOutDiscards": null,
|
|
"ifOutDiscards_prev": null,
|
|
"ifOutDiscards_delta": null,
|
|
"ifOutDiscards_rate": null,
|
|
"ifInUnknownProtos": null,
|
|
"ifInUnknownProtos_prev": null,
|
|
"ifInUnknownProtos_delta": null,
|
|
"ifInUnknownProtos_rate": null,
|
|
"ifInBroadcastPkts": null,
|
|
"ifInBroadcastPkts_prev": null,
|
|
"ifInBroadcastPkts_delta": null,
|
|
"ifInBroadcastPkts_rate": null,
|
|
"ifOutBroadcastPkts": null,
|
|
"ifOutBroadcastPkts_prev": null,
|
|
"ifOutBroadcastPkts_delta": null,
|
|
"ifOutBroadcastPkts_rate": null,
|
|
"ifInMulticastPkts": null,
|
|
"ifInMulticastPkts_prev": null,
|
|
"ifInMulticastPkts_delta": null,
|
|
"ifInMulticastPkts_rate": null,
|
|
"ifOutMulticastPkts": null,
|
|
"ifOutMulticastPkts_prev": null,
|
|
"ifOutMulticastPkts_delta": null,
|
|
"ifOutMulticastPkts_rate": null
|
|
},
|
|
{
|
|
"port_descr_type": null,
|
|
"port_descr_descr": null,
|
|
"port_descr_circuit": null,
|
|
"port_descr_speed": null,
|
|
"port_descr_notes": null,
|
|
"ifDescr": "Siemens, SIMATIC NET, SCALANCE XC206-2SFP, 6GK5 206-2BS00-2AC2, HW: Version 3, FW: Version V04.02.00, SVPM81xxxxx, Aggregation, AG1",
|
|
"ifName": "AG1",
|
|
"portName": null,
|
|
"ifIndex": 53,
|
|
"ifSpeed": null,
|
|
"ifSpeed_prev": null,
|
|
"ifConnectorPresent": null,
|
|
"ifPromiscuousMode": null,
|
|
"ifOperStatus": "up",
|
|
"ifOperStatus_prev": null,
|
|
"ifAdminStatus": null,
|
|
"ifAdminStatus_prev": null,
|
|
"ifDuplex": null,
|
|
"ifMtu": null,
|
|
"ifType": "ieee8023adLag",
|
|
"ifAlias": "po1",
|
|
"ifPhysAddress": null,
|
|
"ifHardType": null,
|
|
"ifLastChange": 0,
|
|
"ifVlan": "",
|
|
"ifTrunk": null,
|
|
"counter_in": null,
|
|
"counter_out": null,
|
|
"ignore": 0,
|
|
"disabled": 0,
|
|
"detailed": 0,
|
|
"deleted": 0,
|
|
"pagpOperationMode": null,
|
|
"pagpPortState": null,
|
|
"pagpPartnerDeviceId": null,
|
|
"pagpPartnerLearnMethod": null,
|
|
"pagpPartnerIfIndex": null,
|
|
"pagpPartnerGroupIfIndex": null,
|
|
"pagpPartnerDeviceName": null,
|
|
"pagpEthcOperationMode": null,
|
|
"pagpDeviceId": null,
|
|
"pagpGroupIfIndex": null,
|
|
"ifInUcastPkts": null,
|
|
"ifInUcastPkts_prev": null,
|
|
"ifInUcastPkts_delta": null,
|
|
"ifInUcastPkts_rate": null,
|
|
"ifOutUcastPkts": null,
|
|
"ifOutUcastPkts_prev": null,
|
|
"ifOutUcastPkts_delta": null,
|
|
"ifOutUcastPkts_rate": null,
|
|
"ifInErrors": null,
|
|
"ifInErrors_prev": null,
|
|
"ifInErrors_delta": null,
|
|
"ifInErrors_rate": null,
|
|
"ifOutErrors": null,
|
|
"ifOutErrors_prev": null,
|
|
"ifOutErrors_delta": null,
|
|
"ifOutErrors_rate": null,
|
|
"ifInOctets": null,
|
|
"ifInOctets_prev": null,
|
|
"ifInOctets_delta": null,
|
|
"ifInOctets_rate": null,
|
|
"ifOutOctets": null,
|
|
"ifOutOctets_prev": null,
|
|
"ifOutOctets_delta": null,
|
|
"ifOutOctets_rate": null,
|
|
"poll_prev": null,
|
|
"ifInNUcastPkts": null,
|
|
"ifInNUcastPkts_prev": null,
|
|
"ifInNUcastPkts_delta": null,
|
|
"ifInNUcastPkts_rate": null,
|
|
"ifOutNUcastPkts": null,
|
|
"ifOutNUcastPkts_prev": null,
|
|
"ifOutNUcastPkts_delta": null,
|
|
"ifOutNUcastPkts_rate": null,
|
|
"ifInDiscards": null,
|
|
"ifInDiscards_prev": null,
|
|
"ifInDiscards_delta": null,
|
|
"ifInDiscards_rate": null,
|
|
"ifOutDiscards": null,
|
|
"ifOutDiscards_prev": null,
|
|
"ifOutDiscards_delta": null,
|
|
"ifOutDiscards_rate": null,
|
|
"ifInUnknownProtos": null,
|
|
"ifInUnknownProtos_prev": null,
|
|
"ifInUnknownProtos_delta": null,
|
|
"ifInUnknownProtos_rate": null,
|
|
"ifInBroadcastPkts": null,
|
|
"ifInBroadcastPkts_prev": null,
|
|
"ifInBroadcastPkts_delta": null,
|
|
"ifInBroadcastPkts_rate": null,
|
|
"ifOutBroadcastPkts": null,
|
|
"ifOutBroadcastPkts_prev": null,
|
|
"ifOutBroadcastPkts_delta": null,
|
|
"ifOutBroadcastPkts_rate": null,
|
|
"ifInMulticastPkts": null,
|
|
"ifInMulticastPkts_prev": null,
|
|
"ifInMulticastPkts_delta": null,
|
|
"ifInMulticastPkts_rate": null,
|
|
"ifOutMulticastPkts": null,
|
|
"ifOutMulticastPkts_prev": null,
|
|
"ifOutMulticastPkts_delta": null,
|
|
"ifOutMulticastPkts_rate": null
|
|
},
|
|
{
|
|
"port_descr_type": null,
|
|
"port_descr_descr": null,
|
|
"port_descr_circuit": null,
|
|
"port_descr_speed": null,
|
|
"port_descr_notes": null,
|
|
"ifDescr": "Siemens, SIMATIC NET, SCALANCE XC206-2SFP, 6GK5 206-2BS00-2AC2, HW: Version 3, FW: Version V04.02.00, SVPM81xxxxx, L3 VLAN, VLAN10",
|
|
"ifName": "vlan10",
|
|
"portName": null,
|
|
"ifIndex": 61,
|
|
"ifSpeed": null,
|
|
"ifSpeed_prev": null,
|
|
"ifConnectorPresent": null,
|
|
"ifPromiscuousMode": null,
|
|
"ifOperStatus": "up",
|
|
"ifOperStatus_prev": null,
|
|
"ifAdminStatus": null,
|
|
"ifAdminStatus_prev": null,
|
|
"ifDuplex": null,
|
|
"ifMtu": null,
|
|
"ifType": "l3ipvlan",
|
|
"ifAlias": "vlan10",
|
|
"ifPhysAddress": null,
|
|
"ifHardType": null,
|
|
"ifLastChange": 0,
|
|
"ifVlan": "",
|
|
"ifTrunk": null,
|
|
"counter_in": null,
|
|
"counter_out": null,
|
|
"ignore": 0,
|
|
"disabled": 0,
|
|
"detailed": 0,
|
|
"deleted": 0,
|
|
"pagpOperationMode": null,
|
|
"pagpPortState": null,
|
|
"pagpPartnerDeviceId": null,
|
|
"pagpPartnerLearnMethod": null,
|
|
"pagpPartnerIfIndex": null,
|
|
"pagpPartnerGroupIfIndex": null,
|
|
"pagpPartnerDeviceName": null,
|
|
"pagpEthcOperationMode": null,
|
|
"pagpDeviceId": null,
|
|
"pagpGroupIfIndex": null,
|
|
"ifInUcastPkts": null,
|
|
"ifInUcastPkts_prev": null,
|
|
"ifInUcastPkts_delta": null,
|
|
"ifInUcastPkts_rate": null,
|
|
"ifOutUcastPkts": null,
|
|
"ifOutUcastPkts_prev": null,
|
|
"ifOutUcastPkts_delta": null,
|
|
"ifOutUcastPkts_rate": null,
|
|
"ifInErrors": null,
|
|
"ifInErrors_prev": null,
|
|
"ifInErrors_delta": null,
|
|
"ifInErrors_rate": null,
|
|
"ifOutErrors": null,
|
|
"ifOutErrors_prev": null,
|
|
"ifOutErrors_delta": null,
|
|
"ifOutErrors_rate": null,
|
|
"ifInOctets": null,
|
|
"ifInOctets_prev": null,
|
|
"ifInOctets_delta": null,
|
|
"ifInOctets_rate": null,
|
|
"ifOutOctets": null,
|
|
"ifOutOctets_prev": null,
|
|
"ifOutOctets_delta": null,
|
|
"ifOutOctets_rate": null,
|
|
"poll_prev": null,
|
|
"ifInNUcastPkts": null,
|
|
"ifInNUcastPkts_prev": null,
|
|
"ifInNUcastPkts_delta": null,
|
|
"ifInNUcastPkts_rate": null,
|
|
"ifOutNUcastPkts": null,
|
|
"ifOutNUcastPkts_prev": null,
|
|
"ifOutNUcastPkts_delta": null,
|
|
"ifOutNUcastPkts_rate": null,
|
|
"ifInDiscards": null,
|
|
"ifInDiscards_prev": null,
|
|
"ifInDiscards_delta": null,
|
|
"ifInDiscards_rate": null,
|
|
"ifOutDiscards": null,
|
|
"ifOutDiscards_prev": null,
|
|
"ifOutDiscards_delta": null,
|
|
"ifOutDiscards_rate": null,
|
|
"ifInUnknownProtos": null,
|
|
"ifInUnknownProtos_prev": null,
|
|
"ifInUnknownProtos_delta": null,
|
|
"ifInUnknownProtos_rate": null,
|
|
"ifInBroadcastPkts": null,
|
|
"ifInBroadcastPkts_prev": null,
|
|
"ifInBroadcastPkts_delta": null,
|
|
"ifInBroadcastPkts_rate": null,
|
|
"ifOutBroadcastPkts": null,
|
|
"ifOutBroadcastPkts_prev": null,
|
|
"ifOutBroadcastPkts_delta": null,
|
|
"ifOutBroadcastPkts_rate": null,
|
|
"ifInMulticastPkts": null,
|
|
"ifInMulticastPkts_prev": null,
|
|
"ifInMulticastPkts_delta": null,
|
|
"ifInMulticastPkts_rate": null,
|
|
"ifOutMulticastPkts": null,
|
|
"ifOutMulticastPkts_prev": null,
|
|
"ifOutMulticastPkts_delta": null,
|
|
"ifOutMulticastPkts_rate": null
|
|
},
|
|
{
|
|
"port_descr_type": null,
|
|
"port_descr_descr": null,
|
|
"port_descr_circuit": null,
|
|
"port_descr_speed": null,
|
|
"port_descr_notes": null,
|
|
"ifDescr": "Siemens, SIMATIC NET, SCALANCE XC206-2SFP, 6GK5 206-2BS00-2AC2, HW: Version 3, FW: Version V04.02.00, SVPM81xxxxx, L3 VLAN, VLAN99",
|
|
"ifName": "vlan99",
|
|
"portName": null,
|
|
"ifIndex": 63,
|
|
"ifSpeed": null,
|
|
"ifSpeed_prev": null,
|
|
"ifConnectorPresent": null,
|
|
"ifPromiscuousMode": null,
|
|
"ifOperStatus": "up",
|
|
"ifOperStatus_prev": null,
|
|
"ifAdminStatus": null,
|
|
"ifAdminStatus_prev": null,
|
|
"ifDuplex": null,
|
|
"ifMtu": null,
|
|
"ifType": "l3ipvlan",
|
|
"ifAlias": "vlan99",
|
|
"ifPhysAddress": null,
|
|
"ifHardType": null,
|
|
"ifLastChange": 0,
|
|
"ifVlan": "",
|
|
"ifTrunk": null,
|
|
"counter_in": null,
|
|
"counter_out": null,
|
|
"ignore": 0,
|
|
"disabled": 0,
|
|
"detailed": 0,
|
|
"deleted": 0,
|
|
"pagpOperationMode": null,
|
|
"pagpPortState": null,
|
|
"pagpPartnerDeviceId": null,
|
|
"pagpPartnerLearnMethod": null,
|
|
"pagpPartnerIfIndex": null,
|
|
"pagpPartnerGroupIfIndex": null,
|
|
"pagpPartnerDeviceName": null,
|
|
"pagpEthcOperationMode": null,
|
|
"pagpDeviceId": null,
|
|
"pagpGroupIfIndex": null,
|
|
"ifInUcastPkts": null,
|
|
"ifInUcastPkts_prev": null,
|
|
"ifInUcastPkts_delta": null,
|
|
"ifInUcastPkts_rate": null,
|
|
"ifOutUcastPkts": null,
|
|
"ifOutUcastPkts_prev": null,
|
|
"ifOutUcastPkts_delta": null,
|
|
"ifOutUcastPkts_rate": null,
|
|
"ifInErrors": null,
|
|
"ifInErrors_prev": null,
|
|
"ifInErrors_delta": null,
|
|
"ifInErrors_rate": null,
|
|
"ifOutErrors": null,
|
|
"ifOutErrors_prev": null,
|
|
"ifOutErrors_delta": null,
|
|
"ifOutErrors_rate": null,
|
|
"ifInOctets": null,
|
|
"ifInOctets_prev": null,
|
|
"ifInOctets_delta": null,
|
|
"ifInOctets_rate": null,
|
|
"ifOutOctets": null,
|
|
"ifOutOctets_prev": null,
|
|
"ifOutOctets_delta": null,
|
|
"ifOutOctets_rate": null,
|
|
"poll_prev": null,
|
|
"ifInNUcastPkts": null,
|
|
"ifInNUcastPkts_prev": null,
|
|
"ifInNUcastPkts_delta": null,
|
|
"ifInNUcastPkts_rate": null,
|
|
"ifOutNUcastPkts": null,
|
|
"ifOutNUcastPkts_prev": null,
|
|
"ifOutNUcastPkts_delta": null,
|
|
"ifOutNUcastPkts_rate": null,
|
|
"ifInDiscards": null,
|
|
"ifInDiscards_prev": null,
|
|
"ifInDiscards_delta": null,
|
|
"ifInDiscards_rate": null,
|
|
"ifOutDiscards": null,
|
|
"ifOutDiscards_prev": null,
|
|
"ifOutDiscards_delta": null,
|
|
"ifOutDiscards_rate": null,
|
|
"ifInUnknownProtos": null,
|
|
"ifInUnknownProtos_prev": null,
|
|
"ifInUnknownProtos_delta": null,
|
|
"ifInUnknownProtos_rate": null,
|
|
"ifInBroadcastPkts": null,
|
|
"ifInBroadcastPkts_prev": null,
|
|
"ifInBroadcastPkts_delta": null,
|
|
"ifInBroadcastPkts_rate": null,
|
|
"ifOutBroadcastPkts": null,
|
|
"ifOutBroadcastPkts_prev": null,
|
|
"ifOutBroadcastPkts_delta": null,
|
|
"ifOutBroadcastPkts_rate": null,
|
|
"ifInMulticastPkts": null,
|
|
"ifInMulticastPkts_prev": null,
|
|
"ifInMulticastPkts_delta": null,
|
|
"ifInMulticastPkts_rate": null,
|
|
"ifOutMulticastPkts": null,
|
|
"ifOutMulticastPkts_prev": null,
|
|
"ifOutMulticastPkts_delta": null,
|
|
"ifOutMulticastPkts_rate": null
|
|
},
|
|
{
|
|
"port_descr_type": null,
|
|
"port_descr_descr": null,
|
|
"port_descr_circuit": null,
|
|
"port_descr_speed": null,
|
|
"port_descr_notes": null,
|
|
"ifDescr": "Siemens, SIMATIC NET, SCALANCE XC206-2SFP, 6GK5 206-2BS00-2AC2, HW: Version 3, FW: Version V04.02.00, SVPM81xxxxx, loopback",
|
|
"ifName": "loopback0",
|
|
"portName": null,
|
|
"ifIndex": 105,
|
|
"ifSpeed": null,
|
|
"ifSpeed_prev": null,
|
|
"ifConnectorPresent": null,
|
|
"ifPromiscuousMode": null,
|
|
"ifOperStatus": "up",
|
|
"ifOperStatus_prev": null,
|
|
"ifAdminStatus": null,
|
|
"ifAdminStatus_prev": null,
|
|
"ifDuplex": null,
|
|
"ifMtu": null,
|
|
"ifType": "softwareLoopback",
|
|
"ifAlias": "Siemens, SIMATIC NET, SCALANCE XC206-2SFP, 6GK5 206-2BS00-2AC2, HW: Version 3, FW: Version V04.02.00, SVPM81xxxxx, loopback",
|
|
"ifPhysAddress": null,
|
|
"ifHardType": null,
|
|
"ifLastChange": 0,
|
|
"ifVlan": "",
|
|
"ifTrunk": null,
|
|
"counter_in": null,
|
|
"counter_out": null,
|
|
"ignore": 0,
|
|
"disabled": 0,
|
|
"detailed": 0,
|
|
"deleted": 0,
|
|
"pagpOperationMode": null,
|
|
"pagpPortState": null,
|
|
"pagpPartnerDeviceId": null,
|
|
"pagpPartnerLearnMethod": null,
|
|
"pagpPartnerIfIndex": null,
|
|
"pagpPartnerGroupIfIndex": null,
|
|
"pagpPartnerDeviceName": null,
|
|
"pagpEthcOperationMode": null,
|
|
"pagpDeviceId": null,
|
|
"pagpGroupIfIndex": null,
|
|
"ifInUcastPkts": null,
|
|
"ifInUcastPkts_prev": null,
|
|
"ifInUcastPkts_delta": null,
|
|
"ifInUcastPkts_rate": null,
|
|
"ifOutUcastPkts": null,
|
|
"ifOutUcastPkts_prev": null,
|
|
"ifOutUcastPkts_delta": null,
|
|
"ifOutUcastPkts_rate": null,
|
|
"ifInErrors": null,
|
|
"ifInErrors_prev": null,
|
|
"ifInErrors_delta": null,
|
|
"ifInErrors_rate": null,
|
|
"ifOutErrors": null,
|
|
"ifOutErrors_prev": null,
|
|
"ifOutErrors_delta": null,
|
|
"ifOutErrors_rate": null,
|
|
"ifInOctets": null,
|
|
"ifInOctets_prev": null,
|
|
"ifInOctets_delta": null,
|
|
"ifInOctets_rate": null,
|
|
"ifOutOctets": null,
|
|
"ifOutOctets_prev": null,
|
|
"ifOutOctets_delta": null,
|
|
"ifOutOctets_rate": null,
|
|
"poll_prev": null,
|
|
"ifInNUcastPkts": null,
|
|
"ifInNUcastPkts_prev": null,
|
|
"ifInNUcastPkts_delta": null,
|
|
"ifInNUcastPkts_rate": null,
|
|
"ifOutNUcastPkts": null,
|
|
"ifOutNUcastPkts_prev": null,
|
|
"ifOutNUcastPkts_delta": null,
|
|
"ifOutNUcastPkts_rate": null,
|
|
"ifInDiscards": null,
|
|
"ifInDiscards_prev": null,
|
|
"ifInDiscards_delta": null,
|
|
"ifInDiscards_rate": null,
|
|
"ifOutDiscards": null,
|
|
"ifOutDiscards_prev": null,
|
|
"ifOutDiscards_delta": null,
|
|
"ifOutDiscards_rate": null,
|
|
"ifInUnknownProtos": null,
|
|
"ifInUnknownProtos_prev": null,
|
|
"ifInUnknownProtos_delta": null,
|
|
"ifInUnknownProtos_rate": null,
|
|
"ifInBroadcastPkts": null,
|
|
"ifInBroadcastPkts_prev": null,
|
|
"ifInBroadcastPkts_delta": null,
|
|
"ifInBroadcastPkts_rate": null,
|
|
"ifOutBroadcastPkts": null,
|
|
"ifOutBroadcastPkts_prev": null,
|
|
"ifOutBroadcastPkts_delta": null,
|
|
"ifOutBroadcastPkts_rate": null,
|
|
"ifInMulticastPkts": null,
|
|
"ifInMulticastPkts_prev": null,
|
|
"ifInMulticastPkts_delta": null,
|
|
"ifInMulticastPkts_rate": null,
|
|
"ifOutMulticastPkts": null,
|
|
"ifOutMulticastPkts_prev": null,
|
|
"ifOutMulticastPkts_delta": null,
|
|
"ifOutMulticastPkts_rate": null
|
|
}
|
|
]
|
|
},
|
|
"poller": {
|
|
"ports": [
|
|
{
|
|
"port_descr_type": "siemens, simatic net, scalance xc206-2sfp, 6gk5 206-2bs00-2ac2, hw",
|
|
"port_descr_descr": "Version 3, FW",
|
|
"port_descr_circuit": null,
|
|
"port_descr_speed": null,
|
|
"port_descr_notes": null,
|
|
"ifDescr": "Siemens, SIMATIC NET, SCALANCE XC206-2SFP, 6GK5 206-2BS00-2AC2, HW: Version 3, FW: Version V04.02.00, SVPM81xxxxx, Ethernet Port, R0/S0/X1 P1",
|
|
"ifName": "P0.1",
|
|
"portName": null,
|
|
"ifIndex": 1,
|
|
"ifSpeed": 100000000,
|
|
"ifSpeed_prev": null,
|
|
"ifConnectorPresent": "true",
|
|
"ifPromiscuousMode": "false",
|
|
"ifOperStatus": "down",
|
|
"ifOperStatus_prev": "down",
|
|
"ifAdminStatus": "up",
|
|
"ifAdminStatus_prev": null,
|
|
"ifDuplex": "halfDuplex",
|
|
"ifMtu": 1500,
|
|
"ifType": "ethernetCsmacd",
|
|
"ifAlias": "Siemens, SIMATIC NET, SCALANCE XC206-2SFP, 6GK5 206-2BS00-2AC2, HW: Version 3, FW: Version V04.02.00, SVPM81xxxxx, Ethernet Port, R0/S0/X1 P1",
|
|
"ifPhysAddress": "d4f527665ad1",
|
|
"ifHardType": null,
|
|
"ifLastChange": 2376,
|
|
"ifVlan": "1000",
|
|
"ifTrunk": null,
|
|
"counter_in": null,
|
|
"counter_out": null,
|
|
"ignore": 0,
|
|
"disabled": 0,
|
|
"detailed": 0,
|
|
"deleted": 0,
|
|
"pagpOperationMode": null,
|
|
"pagpPortState": null,
|
|
"pagpPartnerDeviceId": null,
|
|
"pagpPartnerLearnMethod": null,
|
|
"pagpPartnerIfIndex": null,
|
|
"pagpPartnerGroupIfIndex": null,
|
|
"pagpPartnerDeviceName": null,
|
|
"pagpEthcOperationMode": null,
|
|
"pagpDeviceId": null,
|
|
"pagpGroupIfIndex": null,
|
|
"ifInUcastPkts": 0,
|
|
"ifInUcastPkts_prev": 0,
|
|
"ifInUcastPkts_delta": null,
|
|
"ifInUcastPkts_rate": null,
|
|
"ifOutUcastPkts": 0,
|
|
"ifOutUcastPkts_prev": 0,
|
|
"ifOutUcastPkts_delta": null,
|
|
"ifOutUcastPkts_rate": null,
|
|
"ifInErrors": 0,
|
|
"ifInErrors_prev": 0,
|
|
"ifInErrors_delta": null,
|
|
"ifInErrors_rate": null,
|
|
"ifOutErrors": 0,
|
|
"ifOutErrors_prev": 0,
|
|
"ifOutErrors_delta": null,
|
|
"ifOutErrors_rate": null,
|
|
"ifInOctets": 0,
|
|
"ifInOctets_prev": 0,
|
|
"ifInOctets_delta": null,
|
|
"ifInOctets_rate": null,
|
|
"ifOutOctets": 0,
|
|
"ifOutOctets_prev": 0,
|
|
"ifOutOctets_delta": null,
|
|
"ifOutOctets_rate": null,
|
|
"poll_prev": null,
|
|
"ifInNUcastPkts": 0,
|
|
"ifInNUcastPkts_prev": 0,
|
|
"ifInNUcastPkts_delta": null,
|
|
"ifInNUcastPkts_rate": null,
|
|
"ifOutNUcastPkts": 0,
|
|
"ifOutNUcastPkts_prev": 0,
|
|
"ifOutNUcastPkts_delta": null,
|
|
"ifOutNUcastPkts_rate": null,
|
|
"ifInDiscards": 0,
|
|
"ifInDiscards_prev": 0,
|
|
"ifInDiscards_delta": null,
|
|
"ifInDiscards_rate": null,
|
|
"ifOutDiscards": 0,
|
|
"ifOutDiscards_prev": 0,
|
|
"ifOutDiscards_delta": null,
|
|
"ifOutDiscards_rate": null,
|
|
"ifInUnknownProtos": 0,
|
|
"ifInUnknownProtos_prev": 0,
|
|
"ifInUnknownProtos_delta": null,
|
|
"ifInUnknownProtos_rate": null,
|
|
"ifInBroadcastPkts": 0,
|
|
"ifInBroadcastPkts_prev": 0,
|
|
"ifInBroadcastPkts_delta": null,
|
|
"ifInBroadcastPkts_rate": null,
|
|
"ifOutBroadcastPkts": 0,
|
|
"ifOutBroadcastPkts_prev": 0,
|
|
"ifOutBroadcastPkts_delta": null,
|
|
"ifOutBroadcastPkts_rate": null,
|
|
"ifInMulticastPkts": 0,
|
|
"ifInMulticastPkts_prev": 0,
|
|
"ifInMulticastPkts_delta": null,
|
|
"ifInMulticastPkts_rate": null,
|
|
"ifOutMulticastPkts": 0,
|
|
"ifOutMulticastPkts_prev": 0,
|
|
"ifOutMulticastPkts_delta": null,
|
|
"ifOutMulticastPkts_rate": null
|
|
},
|
|
{
|
|
"port_descr_type": "siemens, simatic net, scalance xc206-2sfp, 6gk5 206-2bs00-2ac2, hw",
|
|
"port_descr_descr": "Version 3, FW",
|
|
"port_descr_circuit": null,
|
|
"port_descr_speed": null,
|
|
"port_descr_notes": null,
|
|
"ifDescr": "Siemens, SIMATIC NET, SCALANCE XC206-2SFP, 6GK5 206-2BS00-2AC2, HW: Version 3, FW: Version V04.02.00, SVPM81xxxxx, Ethernet Port, R0/S0/X1 P2",
|
|
"ifName": "P0.2",
|
|
"portName": null,
|
|
"ifIndex": 2,
|
|
"ifSpeed": 100000000,
|
|
"ifSpeed_prev": null,
|
|
"ifConnectorPresent": "true",
|
|
"ifPromiscuousMode": "false",
|
|
"ifOperStatus": "down",
|
|
"ifOperStatus_prev": "down",
|
|
"ifAdminStatus": "up",
|
|
"ifAdminStatus_prev": null,
|
|
"ifDuplex": "halfDuplex",
|
|
"ifMtu": 1500,
|
|
"ifType": "ethernetCsmacd",
|
|
"ifAlias": "Siemens, SIMATIC NET, SCALANCE XC206-2SFP, 6GK5 206-2BS00-2AC2, HW: Version 3, FW: Version V04.02.00, SVPM81xxxxx, Ethernet Port, R0/S0/X1 P2",
|
|
"ifPhysAddress": "d4f527665ad2",
|
|
"ifHardType": null,
|
|
"ifLastChange": 2376,
|
|
"ifVlan": "1000",
|
|
"ifTrunk": null,
|
|
"counter_in": null,
|
|
"counter_out": null,
|
|
"ignore": 0,
|
|
"disabled": 0,
|
|
"detailed": 0,
|
|
"deleted": 0,
|
|
"pagpOperationMode": null,
|
|
"pagpPortState": null,
|
|
"pagpPartnerDeviceId": null,
|
|
"pagpPartnerLearnMethod": null,
|
|
"pagpPartnerIfIndex": null,
|
|
"pagpPartnerGroupIfIndex": null,
|
|
"pagpPartnerDeviceName": null,
|
|
"pagpEthcOperationMode": null,
|
|
"pagpDeviceId": null,
|
|
"pagpGroupIfIndex": null,
|
|
"ifInUcastPkts": 0,
|
|
"ifInUcastPkts_prev": 0,
|
|
"ifInUcastPkts_delta": null,
|
|
"ifInUcastPkts_rate": null,
|
|
"ifOutUcastPkts": 0,
|
|
"ifOutUcastPkts_prev": 0,
|
|
"ifOutUcastPkts_delta": null,
|
|
"ifOutUcastPkts_rate": null,
|
|
"ifInErrors": 0,
|
|
"ifInErrors_prev": 0,
|
|
"ifInErrors_delta": null,
|
|
"ifInErrors_rate": null,
|
|
"ifOutErrors": 0,
|
|
"ifOutErrors_prev": 0,
|
|
"ifOutErrors_delta": null,
|
|
"ifOutErrors_rate": null,
|
|
"ifInOctets": 0,
|
|
"ifInOctets_prev": 0,
|
|
"ifInOctets_delta": null,
|
|
"ifInOctets_rate": null,
|
|
"ifOutOctets": 0,
|
|
"ifOutOctets_prev": 0,
|
|
"ifOutOctets_delta": null,
|
|
"ifOutOctets_rate": null,
|
|
"poll_prev": null,
|
|
"ifInNUcastPkts": 0,
|
|
"ifInNUcastPkts_prev": 0,
|
|
"ifInNUcastPkts_delta": null,
|
|
"ifInNUcastPkts_rate": null,
|
|
"ifOutNUcastPkts": 0,
|
|
"ifOutNUcastPkts_prev": 0,
|
|
"ifOutNUcastPkts_delta": null,
|
|
"ifOutNUcastPkts_rate": null,
|
|
"ifInDiscards": 0,
|
|
"ifInDiscards_prev": 0,
|
|
"ifInDiscards_delta": null,
|
|
"ifInDiscards_rate": null,
|
|
"ifOutDiscards": 0,
|
|
"ifOutDiscards_prev": 0,
|
|
"ifOutDiscards_delta": null,
|
|
"ifOutDiscards_rate": null,
|
|
"ifInUnknownProtos": 0,
|
|
"ifInUnknownProtos_prev": 0,
|
|
"ifInUnknownProtos_delta": null,
|
|
"ifInUnknownProtos_rate": null,
|
|
"ifInBroadcastPkts": 0,
|
|
"ifInBroadcastPkts_prev": 0,
|
|
"ifInBroadcastPkts_delta": null,
|
|
"ifInBroadcastPkts_rate": null,
|
|
"ifOutBroadcastPkts": 0,
|
|
"ifOutBroadcastPkts_prev": 0,
|
|
"ifOutBroadcastPkts_delta": null,
|
|
"ifOutBroadcastPkts_rate": null,
|
|
"ifInMulticastPkts": 0,
|
|
"ifInMulticastPkts_prev": 0,
|
|
"ifInMulticastPkts_delta": null,
|
|
"ifInMulticastPkts_rate": null,
|
|
"ifOutMulticastPkts": 0,
|
|
"ifOutMulticastPkts_prev": 0,
|
|
"ifOutMulticastPkts_delta": null,
|
|
"ifOutMulticastPkts_rate": null
|
|
},
|
|
{
|
|
"port_descr_type": "siemens, simatic net, scalance xc206-2sfp, 6gk5 206-2bs00-2ac2, hw",
|
|
"port_descr_descr": "Version 3, FW",
|
|
"port_descr_circuit": null,
|
|
"port_descr_speed": null,
|
|
"port_descr_notes": null,
|
|
"ifDescr": "Siemens, SIMATIC NET, SCALANCE XC206-2SFP, 6GK5 206-2BS00-2AC2, HW: Version 3, FW: Version V04.02.00, SVPM81xxxxx, Ethernet Port, R0/S0/X1 P3",
|
|
"ifName": "P0.3",
|
|
"portName": null,
|
|
"ifIndex": 3,
|
|
"ifSpeed": 100000000,
|
|
"ifSpeed_prev": null,
|
|
"ifConnectorPresent": "true",
|
|
"ifPromiscuousMode": "false",
|
|
"ifOperStatus": "down",
|
|
"ifOperStatus_prev": "down",
|
|
"ifAdminStatus": "up",
|
|
"ifAdminStatus_prev": null,
|
|
"ifDuplex": "halfDuplex",
|
|
"ifMtu": 1500,
|
|
"ifType": "ethernetCsmacd",
|
|
"ifAlias": "Siemens, SIMATIC NET, SCALANCE XC206-2SFP, 6GK5 206-2BS00-2AC2, HW: Version 3, FW: Version V04.02.00, SVPM81xxxxx, Ethernet Port, R0/S0/X1 P3",
|
|
"ifPhysAddress": "d4f527665ad3",
|
|
"ifHardType": null,
|
|
"ifLastChange": 2377,
|
|
"ifVlan": "1000",
|
|
"ifTrunk": null,
|
|
"counter_in": null,
|
|
"counter_out": null,
|
|
"ignore": 0,
|
|
"disabled": 0,
|
|
"detailed": 0,
|
|
"deleted": 0,
|
|
"pagpOperationMode": null,
|
|
"pagpPortState": null,
|
|
"pagpPartnerDeviceId": null,
|
|
"pagpPartnerLearnMethod": null,
|
|
"pagpPartnerIfIndex": null,
|
|
"pagpPartnerGroupIfIndex": null,
|
|
"pagpPartnerDeviceName": null,
|
|
"pagpEthcOperationMode": null,
|
|
"pagpDeviceId": null,
|
|
"pagpGroupIfIndex": null,
|
|
"ifInUcastPkts": 0,
|
|
"ifInUcastPkts_prev": 0,
|
|
"ifInUcastPkts_delta": null,
|
|
"ifInUcastPkts_rate": null,
|
|
"ifOutUcastPkts": 0,
|
|
"ifOutUcastPkts_prev": 0,
|
|
"ifOutUcastPkts_delta": null,
|
|
"ifOutUcastPkts_rate": null,
|
|
"ifInErrors": 0,
|
|
"ifInErrors_prev": 0,
|
|
"ifInErrors_delta": null,
|
|
"ifInErrors_rate": null,
|
|
"ifOutErrors": 0,
|
|
"ifOutErrors_prev": 0,
|
|
"ifOutErrors_delta": null,
|
|
"ifOutErrors_rate": null,
|
|
"ifInOctets": 0,
|
|
"ifInOctets_prev": 0,
|
|
"ifInOctets_delta": null,
|
|
"ifInOctets_rate": null,
|
|
"ifOutOctets": 0,
|
|
"ifOutOctets_prev": 0,
|
|
"ifOutOctets_delta": null,
|
|
"ifOutOctets_rate": null,
|
|
"poll_prev": null,
|
|
"ifInNUcastPkts": 0,
|
|
"ifInNUcastPkts_prev": 0,
|
|
"ifInNUcastPkts_delta": null,
|
|
"ifInNUcastPkts_rate": null,
|
|
"ifOutNUcastPkts": 0,
|
|
"ifOutNUcastPkts_prev": 0,
|
|
"ifOutNUcastPkts_delta": null,
|
|
"ifOutNUcastPkts_rate": null,
|
|
"ifInDiscards": 0,
|
|
"ifInDiscards_prev": 0,
|
|
"ifInDiscards_delta": null,
|
|
"ifInDiscards_rate": null,
|
|
"ifOutDiscards": 0,
|
|
"ifOutDiscards_prev": 0,
|
|
"ifOutDiscards_delta": null,
|
|
"ifOutDiscards_rate": null,
|
|
"ifInUnknownProtos": 0,
|
|
"ifInUnknownProtos_prev": 0,
|
|
"ifInUnknownProtos_delta": null,
|
|
"ifInUnknownProtos_rate": null,
|
|
"ifInBroadcastPkts": 0,
|
|
"ifInBroadcastPkts_prev": 0,
|
|
"ifInBroadcastPkts_delta": null,
|
|
"ifInBroadcastPkts_rate": null,
|
|
"ifOutBroadcastPkts": 0,
|
|
"ifOutBroadcastPkts_prev": 0,
|
|
"ifOutBroadcastPkts_delta": null,
|
|
"ifOutBroadcastPkts_rate": null,
|
|
"ifInMulticastPkts": 0,
|
|
"ifInMulticastPkts_prev": 0,
|
|
"ifInMulticastPkts_delta": null,
|
|
"ifInMulticastPkts_rate": null,
|
|
"ifOutMulticastPkts": 0,
|
|
"ifOutMulticastPkts_prev": 0,
|
|
"ifOutMulticastPkts_delta": null,
|
|
"ifOutMulticastPkts_rate": null
|
|
},
|
|
{
|
|
"port_descr_type": "siemens, simatic net, scalance xc206-2sfp, 6gk5 206-2bs00-2ac2, hw",
|
|
"port_descr_descr": "Version 3, FW",
|
|
"port_descr_circuit": null,
|
|
"port_descr_speed": null,
|
|
"port_descr_notes": null,
|
|
"ifDescr": "Siemens, SIMATIC NET, SCALANCE XC206-2SFP, 6GK5 206-2BS00-2AC2, HW: Version 3, FW: Version V04.02.00, SVPM81xxxxx, Ethernet Port, R0/S0/X1 P4",
|
|
"ifName": "P0.4",
|
|
"portName": null,
|
|
"ifIndex": 4,
|
|
"ifSpeed": 100000000,
|
|
"ifSpeed_prev": null,
|
|
"ifConnectorPresent": "true",
|
|
"ifPromiscuousMode": "false",
|
|
"ifOperStatus": "down",
|
|
"ifOperStatus_prev": "down",
|
|
"ifAdminStatus": "up",
|
|
"ifAdminStatus_prev": null,
|
|
"ifDuplex": "halfDuplex",
|
|
"ifMtu": 1500,
|
|
"ifType": "ethernetCsmacd",
|
|
"ifAlias": "Siemens, SIMATIC NET, SCALANCE XC206-2SFP, 6GK5 206-2BS00-2AC2, HW: Version 3, FW: Version V04.02.00, SVPM81xxxxx, Ethernet Port, R0/S0/X1 P4",
|
|
"ifPhysAddress": "d4f527665ad4",
|
|
"ifHardType": null,
|
|
"ifLastChange": 2377,
|
|
"ifVlan": "10",
|
|
"ifTrunk": null,
|
|
"counter_in": null,
|
|
"counter_out": null,
|
|
"ignore": 0,
|
|
"disabled": 0,
|
|
"detailed": 0,
|
|
"deleted": 0,
|
|
"pagpOperationMode": null,
|
|
"pagpPortState": null,
|
|
"pagpPartnerDeviceId": null,
|
|
"pagpPartnerLearnMethod": null,
|
|
"pagpPartnerIfIndex": null,
|
|
"pagpPartnerGroupIfIndex": null,
|
|
"pagpPartnerDeviceName": null,
|
|
"pagpEthcOperationMode": null,
|
|
"pagpDeviceId": null,
|
|
"pagpGroupIfIndex": null,
|
|
"ifInUcastPkts": 0,
|
|
"ifInUcastPkts_prev": 0,
|
|
"ifInUcastPkts_delta": null,
|
|
"ifInUcastPkts_rate": null,
|
|
"ifOutUcastPkts": 0,
|
|
"ifOutUcastPkts_prev": 0,
|
|
"ifOutUcastPkts_delta": null,
|
|
"ifOutUcastPkts_rate": null,
|
|
"ifInErrors": 0,
|
|
"ifInErrors_prev": 0,
|
|
"ifInErrors_delta": null,
|
|
"ifInErrors_rate": null,
|
|
"ifOutErrors": 0,
|
|
"ifOutErrors_prev": 0,
|
|
"ifOutErrors_delta": null,
|
|
"ifOutErrors_rate": null,
|
|
"ifInOctets": 0,
|
|
"ifInOctets_prev": 0,
|
|
"ifInOctets_delta": null,
|
|
"ifInOctets_rate": null,
|
|
"ifOutOctets": 0,
|
|
"ifOutOctets_prev": 0,
|
|
"ifOutOctets_delta": null,
|
|
"ifOutOctets_rate": null,
|
|
"poll_prev": null,
|
|
"ifInNUcastPkts": 0,
|
|
"ifInNUcastPkts_prev": 0,
|
|
"ifInNUcastPkts_delta": null,
|
|
"ifInNUcastPkts_rate": null,
|
|
"ifOutNUcastPkts": 0,
|
|
"ifOutNUcastPkts_prev": 0,
|
|
"ifOutNUcastPkts_delta": null,
|
|
"ifOutNUcastPkts_rate": null,
|
|
"ifInDiscards": 0,
|
|
"ifInDiscards_prev": 0,
|
|
"ifInDiscards_delta": null,
|
|
"ifInDiscards_rate": null,
|
|
"ifOutDiscards": 0,
|
|
"ifOutDiscards_prev": 0,
|
|
"ifOutDiscards_delta": null,
|
|
"ifOutDiscards_rate": null,
|
|
"ifInUnknownProtos": 0,
|
|
"ifInUnknownProtos_prev": 0,
|
|
"ifInUnknownProtos_delta": null,
|
|
"ifInUnknownProtos_rate": null,
|
|
"ifInBroadcastPkts": 0,
|
|
"ifInBroadcastPkts_prev": 0,
|
|
"ifInBroadcastPkts_delta": null,
|
|
"ifInBroadcastPkts_rate": null,
|
|
"ifOutBroadcastPkts": 0,
|
|
"ifOutBroadcastPkts_prev": 0,
|
|
"ifOutBroadcastPkts_delta": null,
|
|
"ifOutBroadcastPkts_rate": null,
|
|
"ifInMulticastPkts": 0,
|
|
"ifInMulticastPkts_prev": 0,
|
|
"ifInMulticastPkts_delta": null,
|
|
"ifInMulticastPkts_rate": null,
|
|
"ifOutMulticastPkts": 0,
|
|
"ifOutMulticastPkts_prev": 0,
|
|
"ifOutMulticastPkts_delta": null,
|
|
"ifOutMulticastPkts_rate": null
|
|
},
|
|
{
|
|
"port_descr_type": "siemens, simatic net, scalance xc206-2sfp, 6gk5 206-2bs00-2ac2, hw",
|
|
"port_descr_descr": "Version 3, FW",
|
|
"port_descr_circuit": null,
|
|
"port_descr_speed": null,
|
|
"port_descr_notes": null,
|
|
"ifDescr": "Siemens, SIMATIC NET, SCALANCE XC206-2SFP, 6GK5 206-2BS00-2AC2, HW: Version 3, FW: Version V04.02.00, SVPM81xxxxx, Ethernet Port, R0/S0/X1 P5",
|
|
"ifName": "P0.5",
|
|
"portName": null,
|
|
"ifIndex": 5,
|
|
"ifSpeed": 100000000,
|
|
"ifSpeed_prev": null,
|
|
"ifConnectorPresent": "true",
|
|
"ifPromiscuousMode": "false",
|
|
"ifOperStatus": "down",
|
|
"ifOperStatus_prev": "down",
|
|
"ifAdminStatus": "up",
|
|
"ifAdminStatus_prev": null,
|
|
"ifDuplex": "halfDuplex",
|
|
"ifMtu": 1500,
|
|
"ifType": "ethernetCsmacd",
|
|
"ifAlias": "Siemens, SIMATIC NET, SCALANCE XC206-2SFP, 6GK5 206-2BS00-2AC2, HW: Version 3, FW: Version V04.02.00, SVPM81xxxxx, Ethernet Port, R0/S0/X1 P5",
|
|
"ifPhysAddress": "d4f527665ad5",
|
|
"ifHardType": null,
|
|
"ifLastChange": 2377,
|
|
"ifVlan": "1000",
|
|
"ifTrunk": null,
|
|
"counter_in": null,
|
|
"counter_out": null,
|
|
"ignore": 0,
|
|
"disabled": 0,
|
|
"detailed": 0,
|
|
"deleted": 0,
|
|
"pagpOperationMode": null,
|
|
"pagpPortState": null,
|
|
"pagpPartnerDeviceId": null,
|
|
"pagpPartnerLearnMethod": null,
|
|
"pagpPartnerIfIndex": null,
|
|
"pagpPartnerGroupIfIndex": null,
|
|
"pagpPartnerDeviceName": null,
|
|
"pagpEthcOperationMode": null,
|
|
"pagpDeviceId": null,
|
|
"pagpGroupIfIndex": null,
|
|
"ifInUcastPkts": 0,
|
|
"ifInUcastPkts_prev": 0,
|
|
"ifInUcastPkts_delta": null,
|
|
"ifInUcastPkts_rate": null,
|
|
"ifOutUcastPkts": 0,
|
|
"ifOutUcastPkts_prev": 0,
|
|
"ifOutUcastPkts_delta": null,
|
|
"ifOutUcastPkts_rate": null,
|
|
"ifInErrors": 0,
|
|
"ifInErrors_prev": 0,
|
|
"ifInErrors_delta": null,
|
|
"ifInErrors_rate": null,
|
|
"ifOutErrors": 0,
|
|
"ifOutErrors_prev": 0,
|
|
"ifOutErrors_delta": null,
|
|
"ifOutErrors_rate": null,
|
|
"ifInOctets": 0,
|
|
"ifInOctets_prev": 0,
|
|
"ifInOctets_delta": null,
|
|
"ifInOctets_rate": null,
|
|
"ifOutOctets": 0,
|
|
"ifOutOctets_prev": 0,
|
|
"ifOutOctets_delta": null,
|
|
"ifOutOctets_rate": null,
|
|
"poll_prev": null,
|
|
"ifInNUcastPkts": 0,
|
|
"ifInNUcastPkts_prev": 0,
|
|
"ifInNUcastPkts_delta": null,
|
|
"ifInNUcastPkts_rate": null,
|
|
"ifOutNUcastPkts": 0,
|
|
"ifOutNUcastPkts_prev": 0,
|
|
"ifOutNUcastPkts_delta": null,
|
|
"ifOutNUcastPkts_rate": null,
|
|
"ifInDiscards": 0,
|
|
"ifInDiscards_prev": 0,
|
|
"ifInDiscards_delta": null,
|
|
"ifInDiscards_rate": null,
|
|
"ifOutDiscards": 0,
|
|
"ifOutDiscards_prev": 0,
|
|
"ifOutDiscards_delta": null,
|
|
"ifOutDiscards_rate": null,
|
|
"ifInUnknownProtos": 0,
|
|
"ifInUnknownProtos_prev": 0,
|
|
"ifInUnknownProtos_delta": null,
|
|
"ifInUnknownProtos_rate": null,
|
|
"ifInBroadcastPkts": 0,
|
|
"ifInBroadcastPkts_prev": 0,
|
|
"ifInBroadcastPkts_delta": null,
|
|
"ifInBroadcastPkts_rate": null,
|
|
"ifOutBroadcastPkts": 0,
|
|
"ifOutBroadcastPkts_prev": 0,
|
|
"ifOutBroadcastPkts_delta": null,
|
|
"ifOutBroadcastPkts_rate": null,
|
|
"ifInMulticastPkts": 0,
|
|
"ifInMulticastPkts_prev": 0,
|
|
"ifInMulticastPkts_delta": null,
|
|
"ifInMulticastPkts_rate": null,
|
|
"ifOutMulticastPkts": 0,
|
|
"ifOutMulticastPkts_prev": 0,
|
|
"ifOutMulticastPkts_delta": null,
|
|
"ifOutMulticastPkts_rate": null
|
|
},
|
|
{
|
|
"port_descr_type": "siemens, simatic net, scalance xc206-2sfp, 6gk5 206-2bs00-2ac2, hw",
|
|
"port_descr_descr": "Version 3, FW",
|
|
"port_descr_circuit": null,
|
|
"port_descr_speed": null,
|
|
"port_descr_notes": null,
|
|
"ifDescr": "Siemens, SIMATIC NET, SCALANCE XC206-2SFP, 6GK5 206-2BS00-2AC2, HW: Version 3, FW: Version V04.02.00, SVPM81xxxxx, Ethernet Port, R0/S0/X1 P6",
|
|
"ifName": "P0.6",
|
|
"portName": null,
|
|
"ifIndex": 6,
|
|
"ifSpeed": 100000000,
|
|
"ifSpeed_prev": null,
|
|
"ifConnectorPresent": "true",
|
|
"ifPromiscuousMode": "false",
|
|
"ifOperStatus": "down",
|
|
"ifOperStatus_prev": "down",
|
|
"ifAdminStatus": "up",
|
|
"ifAdminStatus_prev": null,
|
|
"ifDuplex": "halfDuplex",
|
|
"ifMtu": 1500,
|
|
"ifType": "ethernetCsmacd",
|
|
"ifAlias": "Siemens, SIMATIC NET, SCALANCE XC206-2SFP, 6GK5 206-2BS00-2AC2, HW: Version 3, FW: Version V04.02.00, SVPM81xxxxx, Ethernet Port, R0/S0/X1 P6",
|
|
"ifPhysAddress": "d4f527665ad6",
|
|
"ifHardType": null,
|
|
"ifLastChange": 2377,
|
|
"ifVlan": "1000",
|
|
"ifTrunk": null,
|
|
"counter_in": null,
|
|
"counter_out": null,
|
|
"ignore": 0,
|
|
"disabled": 0,
|
|
"detailed": 0,
|
|
"deleted": 0,
|
|
"pagpOperationMode": null,
|
|
"pagpPortState": null,
|
|
"pagpPartnerDeviceId": null,
|
|
"pagpPartnerLearnMethod": null,
|
|
"pagpPartnerIfIndex": null,
|
|
"pagpPartnerGroupIfIndex": null,
|
|
"pagpPartnerDeviceName": null,
|
|
"pagpEthcOperationMode": null,
|
|
"pagpDeviceId": null,
|
|
"pagpGroupIfIndex": null,
|
|
"ifInUcastPkts": 0,
|
|
"ifInUcastPkts_prev": 0,
|
|
"ifInUcastPkts_delta": null,
|
|
"ifInUcastPkts_rate": null,
|
|
"ifOutUcastPkts": 0,
|
|
"ifOutUcastPkts_prev": 0,
|
|
"ifOutUcastPkts_delta": null,
|
|
"ifOutUcastPkts_rate": null,
|
|
"ifInErrors": 0,
|
|
"ifInErrors_prev": 0,
|
|
"ifInErrors_delta": null,
|
|
"ifInErrors_rate": null,
|
|
"ifOutErrors": 0,
|
|
"ifOutErrors_prev": 0,
|
|
"ifOutErrors_delta": null,
|
|
"ifOutErrors_rate": null,
|
|
"ifInOctets": 0,
|
|
"ifInOctets_prev": 0,
|
|
"ifInOctets_delta": null,
|
|
"ifInOctets_rate": null,
|
|
"ifOutOctets": 0,
|
|
"ifOutOctets_prev": 0,
|
|
"ifOutOctets_delta": null,
|
|
"ifOutOctets_rate": null,
|
|
"poll_prev": null,
|
|
"ifInNUcastPkts": 0,
|
|
"ifInNUcastPkts_prev": 0,
|
|
"ifInNUcastPkts_delta": null,
|
|
"ifInNUcastPkts_rate": null,
|
|
"ifOutNUcastPkts": 0,
|
|
"ifOutNUcastPkts_prev": 0,
|
|
"ifOutNUcastPkts_delta": null,
|
|
"ifOutNUcastPkts_rate": null,
|
|
"ifInDiscards": 0,
|
|
"ifInDiscards_prev": 0,
|
|
"ifInDiscards_delta": null,
|
|
"ifInDiscards_rate": null,
|
|
"ifOutDiscards": 0,
|
|
"ifOutDiscards_prev": 0,
|
|
"ifOutDiscards_delta": null,
|
|
"ifOutDiscards_rate": null,
|
|
"ifInUnknownProtos": 0,
|
|
"ifInUnknownProtos_prev": 0,
|
|
"ifInUnknownProtos_delta": null,
|
|
"ifInUnknownProtos_rate": null,
|
|
"ifInBroadcastPkts": 0,
|
|
"ifInBroadcastPkts_prev": 0,
|
|
"ifInBroadcastPkts_delta": null,
|
|
"ifInBroadcastPkts_rate": null,
|
|
"ifOutBroadcastPkts": 0,
|
|
"ifOutBroadcastPkts_prev": 0,
|
|
"ifOutBroadcastPkts_delta": null,
|
|
"ifOutBroadcastPkts_rate": null,
|
|
"ifInMulticastPkts": 0,
|
|
"ifInMulticastPkts_prev": 0,
|
|
"ifInMulticastPkts_delta": null,
|
|
"ifInMulticastPkts_rate": null,
|
|
"ifOutMulticastPkts": 0,
|
|
"ifOutMulticastPkts_prev": 0,
|
|
"ifOutMulticastPkts_delta": null,
|
|
"ifOutMulticastPkts_rate": null
|
|
},
|
|
{
|
|
"port_descr_type": "siemens, simatic net, 3rd party sfp opt. 1 gbit/s, -, hw",
|
|
"port_descr_descr": "Version A0, FW",
|
|
"port_descr_circuit": null,
|
|
"port_descr_speed": null,
|
|
"port_descr_notes": null,
|
|
"ifDescr": "Siemens, SIMATIC NET, 3rd Party SFP opt. 1 GBit/s, -, HW: Version A0, FW: Version -, S-, Ethernet Port, R0/S0/X1 P7",
|
|
"ifName": "P0.7",
|
|
"portName": null,
|
|
"ifIndex": 7,
|
|
"ifSpeed": 1000000000,
|
|
"ifSpeed_prev": null,
|
|
"ifConnectorPresent": "true",
|
|
"ifPromiscuousMode": "false",
|
|
"ifOperStatus": "down",
|
|
"ifOperStatus_prev": "down",
|
|
"ifAdminStatus": "up",
|
|
"ifAdminStatus_prev": null,
|
|
"ifDuplex": "fullDuplex",
|
|
"ifMtu": 1500,
|
|
"ifType": "ethernetCsmacd",
|
|
"ifAlias": "Siemens, SIMATIC NET, 3rd Party SFP opt. 1 GBit/s, -, HW: Version A0, FW: Version -, S-, Ethernet Port, R0/S0/X1 P7",
|
|
"ifPhysAddress": "d4f527665ad7",
|
|
"ifHardType": null,
|
|
"ifLastChange": 2377,
|
|
"ifVlan": "",
|
|
"ifTrunk": null,
|
|
"counter_in": null,
|
|
"counter_out": null,
|
|
"ignore": 0,
|
|
"disabled": 0,
|
|
"detailed": 0,
|
|
"deleted": 0,
|
|
"pagpOperationMode": null,
|
|
"pagpPortState": null,
|
|
"pagpPartnerDeviceId": null,
|
|
"pagpPartnerLearnMethod": null,
|
|
"pagpPartnerIfIndex": null,
|
|
"pagpPartnerGroupIfIndex": null,
|
|
"pagpPartnerDeviceName": null,
|
|
"pagpEthcOperationMode": null,
|
|
"pagpDeviceId": null,
|
|
"pagpGroupIfIndex": null,
|
|
"ifInUcastPkts": 0,
|
|
"ifInUcastPkts_prev": 0,
|
|
"ifInUcastPkts_delta": null,
|
|
"ifInUcastPkts_rate": null,
|
|
"ifOutUcastPkts": 0,
|
|
"ifOutUcastPkts_prev": 0,
|
|
"ifOutUcastPkts_delta": null,
|
|
"ifOutUcastPkts_rate": null,
|
|
"ifInErrors": 0,
|
|
"ifInErrors_prev": 0,
|
|
"ifInErrors_delta": null,
|
|
"ifInErrors_rate": null,
|
|
"ifOutErrors": 0,
|
|
"ifOutErrors_prev": 0,
|
|
"ifOutErrors_delta": null,
|
|
"ifOutErrors_rate": null,
|
|
"ifInOctets": 0,
|
|
"ifInOctets_prev": 0,
|
|
"ifInOctets_delta": null,
|
|
"ifInOctets_rate": null,
|
|
"ifOutOctets": 0,
|
|
"ifOutOctets_prev": 0,
|
|
"ifOutOctets_delta": null,
|
|
"ifOutOctets_rate": null,
|
|
"poll_prev": null,
|
|
"ifInNUcastPkts": 0,
|
|
"ifInNUcastPkts_prev": 0,
|
|
"ifInNUcastPkts_delta": null,
|
|
"ifInNUcastPkts_rate": null,
|
|
"ifOutNUcastPkts": 0,
|
|
"ifOutNUcastPkts_prev": 0,
|
|
"ifOutNUcastPkts_delta": null,
|
|
"ifOutNUcastPkts_rate": null,
|
|
"ifInDiscards": 0,
|
|
"ifInDiscards_prev": 0,
|
|
"ifInDiscards_delta": null,
|
|
"ifInDiscards_rate": null,
|
|
"ifOutDiscards": 0,
|
|
"ifOutDiscards_prev": 0,
|
|
"ifOutDiscards_delta": null,
|
|
"ifOutDiscards_rate": null,
|
|
"ifInUnknownProtos": 0,
|
|
"ifInUnknownProtos_prev": 0,
|
|
"ifInUnknownProtos_delta": null,
|
|
"ifInUnknownProtos_rate": null,
|
|
"ifInBroadcastPkts": 0,
|
|
"ifInBroadcastPkts_prev": 0,
|
|
"ifInBroadcastPkts_delta": null,
|
|
"ifInBroadcastPkts_rate": null,
|
|
"ifOutBroadcastPkts": 0,
|
|
"ifOutBroadcastPkts_prev": 0,
|
|
"ifOutBroadcastPkts_delta": null,
|
|
"ifOutBroadcastPkts_rate": null,
|
|
"ifInMulticastPkts": 0,
|
|
"ifInMulticastPkts_prev": 0,
|
|
"ifInMulticastPkts_delta": null,
|
|
"ifInMulticastPkts_rate": null,
|
|
"ifOutMulticastPkts": 0,
|
|
"ifOutMulticastPkts_prev": 0,
|
|
"ifOutMulticastPkts_delta": null,
|
|
"ifOutMulticastPkts_rate": null
|
|
},
|
|
{
|
|
"port_descr_type": "siemens, simatic net, sfp992-1ld, 6gk5 992-1am00-8aa0, hw",
|
|
"port_descr_descr": "Version 2, FW",
|
|
"port_descr_circuit": null,
|
|
"port_descr_speed": null,
|
|
"port_descr_notes": null,
|
|
"ifDescr": "Siemens, SIMATIC NET, SFP992-1LD, 6GK5 992-1AM00-8AA0, HW: Version 2, FW: Version -, S-, Ethernet Port, R0/S0/X1 P8",
|
|
"ifName": "P0.8",
|
|
"portName": null,
|
|
"ifIndex": 8,
|
|
"ifSpeed": 1000000000,
|
|
"ifSpeed_prev": null,
|
|
"ifConnectorPresent": "true",
|
|
"ifPromiscuousMode": "false",
|
|
"ifOperStatus": "up",
|
|
"ifOperStatus_prev": "up",
|
|
"ifAdminStatus": "up",
|
|
"ifAdminStatus_prev": null,
|
|
"ifDuplex": "fullDuplex",
|
|
"ifMtu": 1500,
|
|
"ifType": "ethernetCsmacd",
|
|
"ifAlias": "Siemens, SIMATIC NET, SFP992-1LD, 6GK5 992-1AM00-8AA0, HW: Version 2, FW: Version -, S-, Ethernet Port, R0/S0/X1 P8",
|
|
"ifPhysAddress": "d4f527665ad8",
|
|
"ifHardType": null,
|
|
"ifLastChange": 2934,
|
|
"ifVlan": "",
|
|
"ifTrunk": null,
|
|
"counter_in": null,
|
|
"counter_out": null,
|
|
"ignore": 0,
|
|
"disabled": 0,
|
|
"detailed": 0,
|
|
"deleted": 0,
|
|
"pagpOperationMode": null,
|
|
"pagpPortState": null,
|
|
"pagpPartnerDeviceId": null,
|
|
"pagpPartnerLearnMethod": null,
|
|
"pagpPartnerIfIndex": null,
|
|
"pagpPartnerGroupIfIndex": null,
|
|
"pagpPartnerDeviceName": null,
|
|
"pagpEthcOperationMode": null,
|
|
"pagpDeviceId": null,
|
|
"pagpGroupIfIndex": null,
|
|
"ifInUcastPkts": 0,
|
|
"ifInUcastPkts_prev": 0,
|
|
"ifInUcastPkts_delta": null,
|
|
"ifInUcastPkts_rate": null,
|
|
"ifOutUcastPkts": 0,
|
|
"ifOutUcastPkts_prev": 0,
|
|
"ifOutUcastPkts_delta": null,
|
|
"ifOutUcastPkts_rate": null,
|
|
"ifInErrors": 0,
|
|
"ifInErrors_prev": 0,
|
|
"ifInErrors_delta": null,
|
|
"ifInErrors_rate": null,
|
|
"ifOutErrors": 0,
|
|
"ifOutErrors_prev": 0,
|
|
"ifOutErrors_delta": null,
|
|
"ifOutErrors_rate": null,
|
|
"ifInOctets": 51293288436,
|
|
"ifInOctets_prev": 0,
|
|
"ifInOctets_delta": null,
|
|
"ifInOctets_rate": null,
|
|
"ifOutOctets": 750704202,
|
|
"ifOutOctets_prev": 0,
|
|
"ifOutOctets_delta": null,
|
|
"ifOutOctets_rate": null,
|
|
"poll_prev": null,
|
|
"ifInNUcastPkts": 0,
|
|
"ifInNUcastPkts_prev": 0,
|
|
"ifInNUcastPkts_delta": null,
|
|
"ifInNUcastPkts_rate": null,
|
|
"ifOutNUcastPkts": 0,
|
|
"ifOutNUcastPkts_prev": 0,
|
|
"ifOutNUcastPkts_delta": null,
|
|
"ifOutNUcastPkts_rate": null,
|
|
"ifInDiscards": 8609,
|
|
"ifInDiscards_prev": 0,
|
|
"ifInDiscards_delta": null,
|
|
"ifInDiscards_rate": null,
|
|
"ifOutDiscards": 0,
|
|
"ifOutDiscards_prev": 0,
|
|
"ifOutDiscards_delta": null,
|
|
"ifOutDiscards_rate": null,
|
|
"ifInUnknownProtos": 0,
|
|
"ifInUnknownProtos_prev": 0,
|
|
"ifInUnknownProtos_delta": null,
|
|
"ifInUnknownProtos_rate": null,
|
|
"ifInBroadcastPkts": 317050132,
|
|
"ifInBroadcastPkts_prev": 0,
|
|
"ifInBroadcastPkts_delta": null,
|
|
"ifInBroadcastPkts_rate": null,
|
|
"ifOutBroadcastPkts": 16949,
|
|
"ifOutBroadcastPkts_prev": 0,
|
|
"ifOutBroadcastPkts_delta": null,
|
|
"ifOutBroadcastPkts_rate": null,
|
|
"ifInMulticastPkts": 143685347,
|
|
"ifInMulticastPkts_prev": 0,
|
|
"ifInMulticastPkts_delta": null,
|
|
"ifInMulticastPkts_rate": null,
|
|
"ifOutMulticastPkts": 283154,
|
|
"ifOutMulticastPkts_prev": 0,
|
|
"ifOutMulticastPkts_delta": null,
|
|
"ifOutMulticastPkts_rate": null
|
|
},
|
|
{
|
|
"port_descr_type": null,
|
|
"port_descr_descr": null,
|
|
"port_descr_circuit": null,
|
|
"port_descr_speed": null,
|
|
"port_descr_notes": null,
|
|
"ifDescr": "Siemens, SIMATIC NET, SCALANCE XC206-2SFP, 6GK5 206-2BS00-2AC2, HW: Version 3, FW: Version V04.02.00, SVPM81xxxxx, Aggregation, AG1",
|
|
"ifName": "AG1",
|
|
"portName": null,
|
|
"ifIndex": 53,
|
|
"ifSpeed": 1000000000,
|
|
"ifSpeed_prev": null,
|
|
"ifConnectorPresent": "false",
|
|
"ifPromiscuousMode": "false",
|
|
"ifOperStatus": "up",
|
|
"ifOperStatus_prev": "up",
|
|
"ifAdminStatus": "up",
|
|
"ifAdminStatus_prev": null,
|
|
"ifDuplex": null,
|
|
"ifMtu": 1500,
|
|
"ifType": "ieee8023adLag",
|
|
"ifAlias": "po1",
|
|
"ifPhysAddress": "d4f527665ad9",
|
|
"ifHardType": null,
|
|
"ifLastChange": 3700,
|
|
"ifVlan": "1000",
|
|
"ifTrunk": null,
|
|
"counter_in": null,
|
|
"counter_out": null,
|
|
"ignore": 0,
|
|
"disabled": 0,
|
|
"detailed": 0,
|
|
"deleted": 0,
|
|
"pagpOperationMode": null,
|
|
"pagpPortState": null,
|
|
"pagpPartnerDeviceId": null,
|
|
"pagpPartnerLearnMethod": null,
|
|
"pagpPartnerIfIndex": null,
|
|
"pagpPartnerGroupIfIndex": null,
|
|
"pagpPartnerDeviceName": null,
|
|
"pagpEthcOperationMode": null,
|
|
"pagpDeviceId": null,
|
|
"pagpGroupIfIndex": null,
|
|
"ifInUcastPkts": 0,
|
|
"ifInUcastPkts_prev": 0,
|
|
"ifInUcastPkts_delta": null,
|
|
"ifInUcastPkts_rate": null,
|
|
"ifOutUcastPkts": 0,
|
|
"ifOutUcastPkts_prev": 0,
|
|
"ifOutUcastPkts_delta": null,
|
|
"ifOutUcastPkts_rate": null,
|
|
"ifInErrors": 0,
|
|
"ifInErrors_prev": 0,
|
|
"ifInErrors_delta": null,
|
|
"ifInErrors_rate": null,
|
|
"ifOutErrors": 0,
|
|
"ifOutErrors_prev": 0,
|
|
"ifOutErrors_delta": null,
|
|
"ifOutErrors_rate": null,
|
|
"ifInOctets": 51293288436,
|
|
"ifInOctets_prev": 0,
|
|
"ifInOctets_delta": null,
|
|
"ifInOctets_rate": null,
|
|
"ifOutOctets": 750704202,
|
|
"ifOutOctets_prev": 0,
|
|
"ifOutOctets_delta": null,
|
|
"ifOutOctets_rate": null,
|
|
"poll_prev": null,
|
|
"ifInNUcastPkts": 0,
|
|
"ifInNUcastPkts_prev": 0,
|
|
"ifInNUcastPkts_delta": null,
|
|
"ifInNUcastPkts_rate": null,
|
|
"ifOutNUcastPkts": 0,
|
|
"ifOutNUcastPkts_prev": 0,
|
|
"ifOutNUcastPkts_delta": null,
|
|
"ifOutNUcastPkts_rate": null,
|
|
"ifInDiscards": 8609,
|
|
"ifInDiscards_prev": 0,
|
|
"ifInDiscards_delta": null,
|
|
"ifInDiscards_rate": null,
|
|
"ifOutDiscards": 0,
|
|
"ifOutDiscards_prev": 0,
|
|
"ifOutDiscards_delta": null,
|
|
"ifOutDiscards_rate": null,
|
|
"ifInUnknownProtos": 0,
|
|
"ifInUnknownProtos_prev": 0,
|
|
"ifInUnknownProtos_delta": null,
|
|
"ifInUnknownProtos_rate": null,
|
|
"ifInBroadcastPkts": 317050132,
|
|
"ifInBroadcastPkts_prev": 0,
|
|
"ifInBroadcastPkts_delta": null,
|
|
"ifInBroadcastPkts_rate": null,
|
|
"ifOutBroadcastPkts": 16949,
|
|
"ifOutBroadcastPkts_prev": 0,
|
|
"ifOutBroadcastPkts_delta": null,
|
|
"ifOutBroadcastPkts_rate": null,
|
|
"ifInMulticastPkts": 143685347,
|
|
"ifInMulticastPkts_prev": 0,
|
|
"ifInMulticastPkts_delta": null,
|
|
"ifInMulticastPkts_rate": null,
|
|
"ifOutMulticastPkts": 283154,
|
|
"ifOutMulticastPkts_prev": 0,
|
|
"ifOutMulticastPkts_delta": null,
|
|
"ifOutMulticastPkts_rate": null
|
|
},
|
|
{
|
|
"port_descr_type": null,
|
|
"port_descr_descr": null,
|
|
"port_descr_circuit": null,
|
|
"port_descr_speed": null,
|
|
"port_descr_notes": null,
|
|
"ifDescr": "Siemens, SIMATIC NET, SCALANCE XC206-2SFP, 6GK5 206-2BS00-2AC2, HW: Version 3, FW: Version V04.02.00, SVPM81xxxxx, L3 VLAN, VLAN10",
|
|
"ifName": "vlan10",
|
|
"portName": null,
|
|
"ifIndex": 61,
|
|
"ifSpeed": 1000000000,
|
|
"ifSpeed_prev": null,
|
|
"ifConnectorPresent": "false",
|
|
"ifPromiscuousMode": "false",
|
|
"ifOperStatus": "up",
|
|
"ifOperStatus_prev": "up",
|
|
"ifAdminStatus": "up",
|
|
"ifAdminStatus_prev": null,
|
|
"ifDuplex": null,
|
|
"ifMtu": 1500,
|
|
"ifType": "l3ipvlan",
|
|
"ifAlias": "vlan10",
|
|
"ifPhysAddress": "d4f527665ad0",
|
|
"ifHardType": null,
|
|
"ifLastChange": 3706,
|
|
"ifVlan": "",
|
|
"ifTrunk": null,
|
|
"counter_in": null,
|
|
"counter_out": null,
|
|
"ignore": 0,
|
|
"disabled": 0,
|
|
"detailed": 0,
|
|
"deleted": 0,
|
|
"pagpOperationMode": null,
|
|
"pagpPortState": null,
|
|
"pagpPartnerDeviceId": null,
|
|
"pagpPartnerLearnMethod": null,
|
|
"pagpPartnerIfIndex": null,
|
|
"pagpPartnerGroupIfIndex": null,
|
|
"pagpPartnerDeviceName": null,
|
|
"pagpEthcOperationMode": null,
|
|
"pagpDeviceId": null,
|
|
"pagpGroupIfIndex": null,
|
|
"ifInUcastPkts": 0,
|
|
"ifInUcastPkts_prev": 0,
|
|
"ifInUcastPkts_delta": null,
|
|
"ifInUcastPkts_rate": null,
|
|
"ifOutUcastPkts": 0,
|
|
"ifOutUcastPkts_prev": 0,
|
|
"ifOutUcastPkts_delta": null,
|
|
"ifOutUcastPkts_rate": null,
|
|
"ifInErrors": 0,
|
|
"ifInErrors_prev": 0,
|
|
"ifInErrors_delta": null,
|
|
"ifInErrors_rate": null,
|
|
"ifOutErrors": 0,
|
|
"ifOutErrors_prev": 0,
|
|
"ifOutErrors_delta": null,
|
|
"ifOutErrors_rate": null,
|
|
"ifInOctets": 790698592,
|
|
"ifInOctets_prev": 0,
|
|
"ifInOctets_delta": null,
|
|
"ifInOctets_rate": null,
|
|
"ifOutOctets": 638830251,
|
|
"ifOutOctets_prev": 0,
|
|
"ifOutOctets_delta": null,
|
|
"ifOutOctets_rate": null,
|
|
"poll_prev": null,
|
|
"ifInNUcastPkts": 0,
|
|
"ifInNUcastPkts_prev": 0,
|
|
"ifInNUcastPkts_delta": null,
|
|
"ifInNUcastPkts_rate": null,
|
|
"ifOutNUcastPkts": 0,
|
|
"ifOutNUcastPkts_prev": 0,
|
|
"ifOutNUcastPkts_delta": null,
|
|
"ifOutNUcastPkts_rate": null,
|
|
"ifInDiscards": 1279,
|
|
"ifInDiscards_prev": 0,
|
|
"ifInDiscards_delta": null,
|
|
"ifInDiscards_rate": null,
|
|
"ifOutDiscards": 0,
|
|
"ifOutDiscards_prev": 0,
|
|
"ifOutDiscards_delta": null,
|
|
"ifOutDiscards_rate": null,
|
|
"ifInUnknownProtos": 0,
|
|
"ifInUnknownProtos_prev": 0,
|
|
"ifInUnknownProtos_delta": null,
|
|
"ifInUnknownProtos_rate": null,
|
|
"ifInBroadcastPkts": 0,
|
|
"ifInBroadcastPkts_prev": 0,
|
|
"ifInBroadcastPkts_delta": null,
|
|
"ifInBroadcastPkts_rate": null,
|
|
"ifOutBroadcastPkts": 0,
|
|
"ifOutBroadcastPkts_prev": 0,
|
|
"ifOutBroadcastPkts_delta": null,
|
|
"ifOutBroadcastPkts_rate": null,
|
|
"ifInMulticastPkts": 0,
|
|
"ifInMulticastPkts_prev": 0,
|
|
"ifInMulticastPkts_delta": null,
|
|
"ifInMulticastPkts_rate": null,
|
|
"ifOutMulticastPkts": 0,
|
|
"ifOutMulticastPkts_prev": 0,
|
|
"ifOutMulticastPkts_delta": null,
|
|
"ifOutMulticastPkts_rate": null
|
|
},
|
|
{
|
|
"port_descr_type": null,
|
|
"port_descr_descr": null,
|
|
"port_descr_circuit": null,
|
|
"port_descr_speed": null,
|
|
"port_descr_notes": null,
|
|
"ifDescr": "Siemens, SIMATIC NET, SCALANCE XC206-2SFP, 6GK5 206-2BS00-2AC2, HW: Version 3, FW: Version V04.02.00, SVPM81xxxxx, L3 VLAN, VLAN99",
|
|
"ifName": "vlan99",
|
|
"portName": null,
|
|
"ifIndex": 63,
|
|
"ifSpeed": 1000000000,
|
|
"ifSpeed_prev": null,
|
|
"ifConnectorPresent": "false",
|
|
"ifPromiscuousMode": "false",
|
|
"ifOperStatus": "up",
|
|
"ifOperStatus_prev": "up",
|
|
"ifAdminStatus": "up",
|
|
"ifAdminStatus_prev": null,
|
|
"ifDuplex": null,
|
|
"ifMtu": 1500,
|
|
"ifType": "l3ipvlan",
|
|
"ifAlias": "vlan99",
|
|
"ifPhysAddress": "d4f527665ad0",
|
|
"ifHardType": null,
|
|
"ifLastChange": 3707,
|
|
"ifVlan": "",
|
|
"ifTrunk": null,
|
|
"counter_in": null,
|
|
"counter_out": null,
|
|
"ignore": 0,
|
|
"disabled": 0,
|
|
"detailed": 0,
|
|
"deleted": 0,
|
|
"pagpOperationMode": null,
|
|
"pagpPortState": null,
|
|
"pagpPartnerDeviceId": null,
|
|
"pagpPartnerLearnMethod": null,
|
|
"pagpPartnerIfIndex": null,
|
|
"pagpPartnerGroupIfIndex": null,
|
|
"pagpPartnerDeviceName": null,
|
|
"pagpEthcOperationMode": null,
|
|
"pagpDeviceId": null,
|
|
"pagpGroupIfIndex": null,
|
|
"ifInUcastPkts": 0,
|
|
"ifInUcastPkts_prev": 0,
|
|
"ifInUcastPkts_delta": null,
|
|
"ifInUcastPkts_rate": null,
|
|
"ifOutUcastPkts": 0,
|
|
"ifOutUcastPkts_prev": 0,
|
|
"ifOutUcastPkts_delta": null,
|
|
"ifOutUcastPkts_rate": null,
|
|
"ifInErrors": 0,
|
|
"ifInErrors_prev": 0,
|
|
"ifInErrors_delta": null,
|
|
"ifInErrors_rate": null,
|
|
"ifOutErrors": 0,
|
|
"ifOutErrors_prev": 0,
|
|
"ifOutErrors_delta": null,
|
|
"ifOutErrors_rate": null,
|
|
"ifInOctets": 0,
|
|
"ifInOctets_prev": 0,
|
|
"ifInOctets_delta": null,
|
|
"ifInOctets_rate": null,
|
|
"ifOutOctets": 402,
|
|
"ifOutOctets_prev": 0,
|
|
"ifOutOctets_delta": null,
|
|
"ifOutOctets_rate": null,
|
|
"poll_prev": null,
|
|
"ifInNUcastPkts": 0,
|
|
"ifInNUcastPkts_prev": 0,
|
|
"ifInNUcastPkts_delta": null,
|
|
"ifInNUcastPkts_rate": null,
|
|
"ifOutNUcastPkts": 0,
|
|
"ifOutNUcastPkts_prev": 0,
|
|
"ifOutNUcastPkts_delta": null,
|
|
"ifOutNUcastPkts_rate": null,
|
|
"ifInDiscards": 0,
|
|
"ifInDiscards_prev": 0,
|
|
"ifInDiscards_delta": null,
|
|
"ifInDiscards_rate": null,
|
|
"ifOutDiscards": 0,
|
|
"ifOutDiscards_prev": 0,
|
|
"ifOutDiscards_delta": null,
|
|
"ifOutDiscards_rate": null,
|
|
"ifInUnknownProtos": 0,
|
|
"ifInUnknownProtos_prev": 0,
|
|
"ifInUnknownProtos_delta": null,
|
|
"ifInUnknownProtos_rate": null,
|
|
"ifInBroadcastPkts": 0,
|
|
"ifInBroadcastPkts_prev": 0,
|
|
"ifInBroadcastPkts_delta": null,
|
|
"ifInBroadcastPkts_rate": null,
|
|
"ifOutBroadcastPkts": 0,
|
|
"ifOutBroadcastPkts_prev": 0,
|
|
"ifOutBroadcastPkts_delta": null,
|
|
"ifOutBroadcastPkts_rate": null,
|
|
"ifInMulticastPkts": 0,
|
|
"ifInMulticastPkts_prev": 0,
|
|
"ifInMulticastPkts_delta": null,
|
|
"ifInMulticastPkts_rate": null,
|
|
"ifOutMulticastPkts": 0,
|
|
"ifOutMulticastPkts_prev": 0,
|
|
"ifOutMulticastPkts_delta": null,
|
|
"ifOutMulticastPkts_rate": null
|
|
},
|
|
{
|
|
"port_descr_type": "siemens, simatic net, scalance xc206-2sfp, 6gk5 206-2bs00-2ac2, hw",
|
|
"port_descr_descr": "Version 3, FW",
|
|
"port_descr_circuit": null,
|
|
"port_descr_speed": null,
|
|
"port_descr_notes": null,
|
|
"ifDescr": "Siemens, SIMATIC NET, SCALANCE XC206-2SFP, 6GK5 206-2BS00-2AC2, HW: Version 3, FW: Version V04.02.00, SVPM81xxxxx, loopback",
|
|
"ifName": "loopback0",
|
|
"portName": null,
|
|
"ifIndex": 105,
|
|
"ifSpeed": 1000000000,
|
|
"ifSpeed_prev": null,
|
|
"ifConnectorPresent": "false",
|
|
"ifPromiscuousMode": "false",
|
|
"ifOperStatus": "up",
|
|
"ifOperStatus_prev": "up",
|
|
"ifAdminStatus": "up",
|
|
"ifAdminStatus_prev": null,
|
|
"ifDuplex": null,
|
|
"ifMtu": 1500,
|
|
"ifType": "softwareLoopback",
|
|
"ifAlias": "Siemens, SIMATIC NET, SCALANCE XC206-2SFP, 6GK5 206-2BS00-2AC2, HW: Version 3, FW: Version V04.02.00, SVPM81xxxxx, loopback",
|
|
"ifPhysAddress": null,
|
|
"ifHardType": null,
|
|
"ifLastChange": 1728,
|
|
"ifVlan": "",
|
|
"ifTrunk": null,
|
|
"counter_in": null,
|
|
"counter_out": null,
|
|
"ignore": 0,
|
|
"disabled": 0,
|
|
"detailed": 0,
|
|
"deleted": 0,
|
|
"pagpOperationMode": null,
|
|
"pagpPortState": null,
|
|
"pagpPartnerDeviceId": null,
|
|
"pagpPartnerLearnMethod": null,
|
|
"pagpPartnerIfIndex": null,
|
|
"pagpPartnerGroupIfIndex": null,
|
|
"pagpPartnerDeviceName": null,
|
|
"pagpEthcOperationMode": null,
|
|
"pagpDeviceId": null,
|
|
"pagpGroupIfIndex": null,
|
|
"ifInUcastPkts": 0,
|
|
"ifInUcastPkts_prev": 0,
|
|
"ifInUcastPkts_delta": null,
|
|
"ifInUcastPkts_rate": null,
|
|
"ifOutUcastPkts": 0,
|
|
"ifOutUcastPkts_prev": 0,
|
|
"ifOutUcastPkts_delta": null,
|
|
"ifOutUcastPkts_rate": null,
|
|
"ifInErrors": 0,
|
|
"ifInErrors_prev": 0,
|
|
"ifInErrors_delta": null,
|
|
"ifInErrors_rate": null,
|
|
"ifOutErrors": 0,
|
|
"ifOutErrors_prev": 0,
|
|
"ifOutErrors_delta": null,
|
|
"ifOutErrors_rate": null,
|
|
"ifInOctets": 0,
|
|
"ifInOctets_prev": 0,
|
|
"ifInOctets_delta": null,
|
|
"ifInOctets_rate": null,
|
|
"ifOutOctets": 0,
|
|
"ifOutOctets_prev": 0,
|
|
"ifOutOctets_delta": null,
|
|
"ifOutOctets_rate": null,
|
|
"poll_prev": null,
|
|
"ifInNUcastPkts": 0,
|
|
"ifInNUcastPkts_prev": 0,
|
|
"ifInNUcastPkts_delta": null,
|
|
"ifInNUcastPkts_rate": null,
|
|
"ifOutNUcastPkts": 0,
|
|
"ifOutNUcastPkts_prev": 0,
|
|
"ifOutNUcastPkts_delta": null,
|
|
"ifOutNUcastPkts_rate": null,
|
|
"ifInDiscards": 0,
|
|
"ifInDiscards_prev": 0,
|
|
"ifInDiscards_delta": null,
|
|
"ifInDiscards_rate": null,
|
|
"ifOutDiscards": 0,
|
|
"ifOutDiscards_prev": 0,
|
|
"ifOutDiscards_delta": null,
|
|
"ifOutDiscards_rate": null,
|
|
"ifInUnknownProtos": 0,
|
|
"ifInUnknownProtos_prev": 0,
|
|
"ifInUnknownProtos_delta": null,
|
|
"ifInUnknownProtos_rate": null,
|
|
"ifInBroadcastPkts": 0,
|
|
"ifInBroadcastPkts_prev": 0,
|
|
"ifInBroadcastPkts_delta": null,
|
|
"ifInBroadcastPkts_rate": null,
|
|
"ifOutBroadcastPkts": 0,
|
|
"ifOutBroadcastPkts_prev": 0,
|
|
"ifOutBroadcastPkts_delta": null,
|
|
"ifOutBroadcastPkts_rate": null,
|
|
"ifInMulticastPkts": 0,
|
|
"ifInMulticastPkts_prev": 0,
|
|
"ifInMulticastPkts_delta": null,
|
|
"ifInMulticastPkts_rate": null,
|
|
"ifOutMulticastPkts": 0,
|
|
"ifOutMulticastPkts_prev": 0,
|
|
"ifOutMulticastPkts_delta": null,
|
|
"ifOutMulticastPkts_rate": null
|
|
}
|
|
]
|
|
}
|
|
},
|
|
"processors": {
|
|
"discovery": {
|
|
"processors": [
|
|
{
|
|
"entPhysicalIndex": 0,
|
|
"hrDeviceIndex": 0,
|
|
"processor_oid": ".1.3.6.1.4.1.4329.20.1.1.1.1.79.3.1.13.0",
|
|
"processor_index": "0",
|
|
"processor_type": "scalance-cpu",
|
|
"processor_usage": 54,
|
|
"processor_descr": "Processor",
|
|
"processor_precision": 1,
|
|
"processor_perc_warn": 75
|
|
}
|
|
]
|
|
},
|
|
"poller": "matches discovery"
|
|
},
|
|
"mempools": {
|
|
"discovery": {
|
|
"mempools": [
|
|
{
|
|
"mempool_index": "0",
|
|
"entPhysicalIndex": null,
|
|
"mempool_type": "scalance",
|
|
"mempool_class": "system",
|
|
"mempool_precision": 1,
|
|
"mempool_descr": "Memory",
|
|
"mempool_perc": 59,
|
|
"mempool_perc_oid": ".1.3.6.1.4.1.4329.20.1.1.1.1.79.3.1.13.1",
|
|
"mempool_used": 59,
|
|
"mempool_used_oid": null,
|
|
"mempool_free": 41,
|
|
"mempool_free_oid": null,
|
|
"mempool_total": 100,
|
|
"mempool_total_oid": null,
|
|
"mempool_largestfree": null,
|
|
"mempool_lowestfree": null,
|
|
"mempool_deleted": 0,
|
|
"mempool_perc_warn": 90
|
|
}
|
|
]
|
|
},
|
|
"poller": "matches discovery"
|
|
},
|
|
"sensors": {
|
|
"discovery": {
|
|
"sensors": [
|
|
{
|
|
"sensor_deleted": 0,
|
|
"sensor_class": "current",
|
|
"poller_type": "snmp",
|
|
"sensor_oid": ".1.3.6.1.4.1.4329.20.1.1.1.1.46.10.1.16.7",
|
|
"sensor_index": "snMspsSfpCurrent.7",
|
|
"sensor_type": "scalance",
|
|
"sensor_descr": "P0.7 Bias Current",
|
|
"group": null,
|
|
"sensor_divisor": 100000,
|
|
"sensor_multiplier": 1,
|
|
"sensor_current": 0.01591,
|
|
"sensor_limit": 0.1,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": 0,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": 1,
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_prev": null,
|
|
"user_func": null,
|
|
"state_name": null
|
|
},
|
|
{
|
|
"sensor_deleted": 0,
|
|
"sensor_class": "current",
|
|
"poller_type": "snmp",
|
|
"sensor_oid": ".1.3.6.1.4.1.4329.20.1.1.1.1.46.10.1.16.8",
|
|
"sensor_index": "snMspsSfpCurrent.8",
|
|
"sensor_type": "scalance",
|
|
"sensor_descr": "P0.8 Bias Current",
|
|
"group": null,
|
|
"sensor_divisor": 100000,
|
|
"sensor_multiplier": 1,
|
|
"sensor_current": 0.01687,
|
|
"sensor_limit": 0.065,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": 0.001,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": 1,
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_prev": null,
|
|
"user_func": null,
|
|
"state_name": null
|
|
},
|
|
{
|
|
"sensor_deleted": 0,
|
|
"sensor_class": "dbm",
|
|
"poller_type": "snmp",
|
|
"sensor_oid": ".1.3.6.1.4.1.4329.20.1.1.1.1.46.10.1.32.7",
|
|
"sensor_index": "snMspsSfpRxPowerdBm.7",
|
|
"sensor_type": "scalance",
|
|
"sensor_descr": "P0.7 Receive Power",
|
|
"group": null,
|
|
"sensor_divisor": 10,
|
|
"sensor_multiplier": 1,
|
|
"sensor_current": -99.9,
|
|
"sensor_limit": -2,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": -9.9,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": 1,
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_prev": null,
|
|
"user_func": null,
|
|
"state_name": null
|
|
},
|
|
{
|
|
"sensor_deleted": 0,
|
|
"sensor_class": "dbm",
|
|
"poller_type": "snmp",
|
|
"sensor_oid": ".1.3.6.1.4.1.4329.20.1.1.1.1.46.10.1.32.8",
|
|
"sensor_index": "snMspsSfpRxPowerdBm.8",
|
|
"sensor_type": "scalance",
|
|
"sensor_descr": "P0.8 Receive Power",
|
|
"group": null,
|
|
"sensor_divisor": 10,
|
|
"sensor_multiplier": 1,
|
|
"sensor_current": -1.8,
|
|
"sensor_limit": -1,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": -11.4,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": 1,
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_prev": null,
|
|
"user_func": null,
|
|
"state_name": null
|
|
},
|
|
{
|
|
"sensor_deleted": 0,
|
|
"sensor_class": "dbm",
|
|
"poller_type": "snmp",
|
|
"sensor_oid": ".1.3.6.1.4.1.4329.20.1.1.1.1.46.10.1.35.7",
|
|
"sensor_index": "snMspsSfpTxPowerdBm.7",
|
|
"sensor_type": "scalance",
|
|
"sensor_descr": "P0.7 Transmit Power",
|
|
"group": null,
|
|
"sensor_divisor": 10,
|
|
"sensor_multiplier": 1,
|
|
"sensor_current": -6.1,
|
|
"sensor_limit": -2,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": -9.9,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": 1,
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_prev": null,
|
|
"user_func": null,
|
|
"state_name": null
|
|
},
|
|
{
|
|
"sensor_deleted": 0,
|
|
"sensor_class": "dbm",
|
|
"poller_type": "snmp",
|
|
"sensor_oid": ".1.3.6.1.4.1.4329.20.1.1.1.1.46.10.1.35.8",
|
|
"sensor_index": "snMspsSfpTxPowerdBm.8",
|
|
"sensor_type": "scalance",
|
|
"sensor_descr": "P0.8 Transmit Power",
|
|
"group": null,
|
|
"sensor_divisor": 10,
|
|
"sensor_multiplier": 1,
|
|
"sensor_current": -5.4,
|
|
"sensor_limit": -1,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": -11.4,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": 1,
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_prev": null,
|
|
"user_func": null,
|
|
"state_name": null
|
|
},
|
|
{
|
|
"sensor_deleted": 0,
|
|
"sensor_class": "state",
|
|
"poller_type": "snmp",
|
|
"sensor_oid": ".1.3.6.1.4.1.4329.20.1.1.1.1.35.1.0",
|
|
"sensor_index": "0",
|
|
"sensor_type": "C-Plug",
|
|
"sensor_descr": "C-Plug",
|
|
"group": "Plugs",
|
|
"sensor_divisor": 1,
|
|
"sensor_multiplier": 1,
|
|
"sensor_current": 1,
|
|
"sensor_limit": null,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": null,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": 1,
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_prev": null,
|
|
"user_func": null,
|
|
"state_name": "C-Plug"
|
|
},
|
|
{
|
|
"sensor_deleted": 0,
|
|
"sensor_class": "state",
|
|
"poller_type": "snmp",
|
|
"sensor_oid": ".1.3.6.1.4.1.4329.20.1.1.1.1.28.1.0",
|
|
"sensor_index": "0",
|
|
"sensor_type": "Faults",
|
|
"sensor_descr": "Faults",
|
|
"group": "System",
|
|
"sensor_divisor": 1,
|
|
"sensor_multiplier": 1,
|
|
"sensor_current": 1,
|
|
"sensor_limit": null,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": null,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": 1,
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_prev": null,
|
|
"user_func": null,
|
|
"state_name": "Faults"
|
|
},
|
|
{
|
|
"sensor_deleted": 0,
|
|
"sensor_class": "state",
|
|
"poller_type": "snmp",
|
|
"sensor_oid": ".1.3.6.1.4.1.4329.20.1.1.1.1.28.4.0",
|
|
"sensor_index": "0",
|
|
"sensor_type": "Power Supply 1",
|
|
"sensor_descr": "Power Supply 1",
|
|
"group": "Power",
|
|
"sensor_divisor": 1,
|
|
"sensor_multiplier": 1,
|
|
"sensor_current": 2,
|
|
"sensor_limit": null,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": null,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": 1,
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_prev": null,
|
|
"user_func": null,
|
|
"state_name": "Power Supply 1"
|
|
},
|
|
{
|
|
"sensor_deleted": 0,
|
|
"sensor_class": "state",
|
|
"poller_type": "snmp",
|
|
"sensor_oid": ".1.3.6.1.4.1.4329.20.1.1.1.1.28.5.0",
|
|
"sensor_index": "0",
|
|
"sensor_type": "Power Supply 2",
|
|
"sensor_descr": "Power Supply 2",
|
|
"group": "Power",
|
|
"sensor_divisor": 1,
|
|
"sensor_multiplier": 1,
|
|
"sensor_current": 1,
|
|
"sensor_limit": null,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": null,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": 1,
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_prev": null,
|
|
"user_func": null,
|
|
"state_name": "Power Supply 2"
|
|
},
|
|
{
|
|
"sensor_deleted": 0,
|
|
"sensor_class": "temperature",
|
|
"poller_type": "snmp",
|
|
"sensor_oid": ".1.3.6.1.4.1.4329.20.1.1.1.1.79.7.1.16.0",
|
|
"sensor_index": "snMspsDiagnosticsTemperatureValue.0",
|
|
"sensor_type": "scalance",
|
|
"sensor_descr": "Chassis",
|
|
"group": null,
|
|
"sensor_divisor": 1,
|
|
"sensor_multiplier": 1,
|
|
"sensor_current": 35,
|
|
"sensor_limit": 55,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": 25,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": 1,
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_prev": null,
|
|
"user_func": null,
|
|
"state_name": null
|
|
},
|
|
{
|
|
"sensor_deleted": 0,
|
|
"sensor_class": "temperature",
|
|
"poller_type": "snmp",
|
|
"sensor_oid": ".1.3.6.1.4.1.4329.20.1.1.1.1.79.7.1.16.1",
|
|
"sensor_index": "snMspsDiagnosticsTemperatureValue.1",
|
|
"sensor_type": "scalance",
|
|
"sensor_descr": "P0.7 3rd Party S\n46 50 20 6F 70 74 2E 20 31 20 47 42 69 74 2F 73 \n00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 \n00 00 00 00 ",
|
|
"group": null,
|
|
"sensor_divisor": 1,
|
|
"sensor_multiplier": 1,
|
|
"sensor_current": 30,
|
|
"sensor_limit": 50,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": 20,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": 1,
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_prev": null,
|
|
"user_func": null,
|
|
"state_name": null
|
|
},
|
|
{
|
|
"sensor_deleted": 0,
|
|
"sensor_class": "temperature",
|
|
"poller_type": "snmp",
|
|
"sensor_oid": ".1.3.6.1.4.1.4329.20.1.1.1.1.79.7.1.16.2",
|
|
"sensor_index": "snMspsDiagnosticsTemperatureValue.2",
|
|
"sensor_type": "scalance",
|
|
"sensor_descr": "P0.8 SFP992-1LD.\n00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 \n00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 \n00 00 00 00 ",
|
|
"group": null,
|
|
"sensor_divisor": 1,
|
|
"sensor_multiplier": 1,
|
|
"sensor_current": 41,
|
|
"sensor_limit": 61,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": 31,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": 1,
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_prev": null,
|
|
"user_func": null,
|
|
"state_name": null
|
|
},
|
|
{
|
|
"sensor_deleted": 0,
|
|
"sensor_class": "voltage",
|
|
"poller_type": "snmp",
|
|
"sensor_oid": ".1.3.6.1.4.1.4329.20.1.1.1.1.46.10.1.13.7",
|
|
"sensor_index": "snMspsSfpVoltage.7",
|
|
"sensor_type": "scalance",
|
|
"sensor_descr": "P0.7 Supply Voltage",
|
|
"group": null,
|
|
"sensor_divisor": 100,
|
|
"sensor_multiplier": 1,
|
|
"sensor_current": 3.27,
|
|
"sensor_limit": 3.8,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": 2.7,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": 1,
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_prev": null,
|
|
"user_func": null,
|
|
"state_name": null
|
|
},
|
|
{
|
|
"sensor_deleted": 0,
|
|
"sensor_class": "voltage",
|
|
"poller_type": "snmp",
|
|
"sensor_oid": ".1.3.6.1.4.1.4329.20.1.1.1.1.46.10.1.13.8",
|
|
"sensor_index": "snMspsSfpVoltage.8",
|
|
"sensor_type": "scalance",
|
|
"sensor_descr": "P0.8 Supply Voltage",
|
|
"group": null,
|
|
"sensor_divisor": 100,
|
|
"sensor_multiplier": 1,
|
|
"sensor_current": 3.3,
|
|
"sensor_limit": 3.7,
|
|
"sensor_limit_warn": null,
|
|
"sensor_limit_low": 2.9,
|
|
"sensor_limit_low_warn": null,
|
|
"sensor_alert": 1,
|
|
"sensor_custom": "No",
|
|
"entPhysicalIndex": null,
|
|
"entPhysicalIndex_measured": null,
|
|
"sensor_prev": null,
|
|
"user_func": null,
|
|
"state_name": null
|
|
}
|
|
],
|
|
"state_indexes": [
|
|
{
|
|
"state_name": "C-Plug",
|
|
"state_descr": "notPresent",
|
|
"state_draw_graph": 0,
|
|
"state_value": 1,
|
|
"state_generic_value": 2
|
|
},
|
|
{
|
|
"state_name": "C-Plug",
|
|
"state_descr": "notAccepted",
|
|
"state_draw_graph": 0,
|
|
"state_value": 4,
|
|
"state_generic_value": 2
|
|
},
|
|
{
|
|
"state_name": "C-Plug",
|
|
"state_descr": "accepted",
|
|
"state_draw_graph": 1,
|
|
"state_value": 5,
|
|
"state_generic_value": 0
|
|
},
|
|
{
|
|
"state_name": "C-Plug",
|
|
"state_descr": "factory",
|
|
"state_draw_graph": 0,
|
|
"state_value": 6,
|
|
"state_generic_value": 2
|
|
},
|
|
{
|
|
"state_name": "C-Plug",
|
|
"state_descr": "missing",
|
|
"state_draw_graph": 0,
|
|
"state_value": 7,
|
|
"state_generic_value": 2
|
|
},
|
|
{
|
|
"state_name": "Faults",
|
|
"state_descr": "noFault",
|
|
"state_draw_graph": 0,
|
|
"state_value": 1,
|
|
"state_generic_value": 0
|
|
},
|
|
{
|
|
"state_name": "Faults",
|
|
"state_descr": "fault",
|
|
"state_draw_graph": 1,
|
|
"state_value": 2,
|
|
"state_generic_value": 2
|
|
},
|
|
{
|
|
"state_name": "Power Supply 1",
|
|
"state_descr": "active",
|
|
"state_draw_graph": 1,
|
|
"state_value": 0,
|
|
"state_generic_value": 0
|
|
},
|
|
{
|
|
"state_name": "Power Supply 1",
|
|
"state_descr": "inactive",
|
|
"state_draw_graph": 0,
|
|
"state_value": 1,
|
|
"state_generic_value": 2
|
|
},
|
|
{
|
|
"state_name": "Power Supply 2",
|
|
"state_descr": "active",
|
|
"state_draw_graph": 1,
|
|
"state_value": 0,
|
|
"state_generic_value": 0
|
|
},
|
|
{
|
|
"state_name": "Power Supply 2",
|
|
"state_descr": "inactive",
|
|
"state_draw_graph": 0,
|
|
"state_value": 1,
|
|
"state_generic_value": 2
|
|
}
|
|
]
|
|
},
|
|
"poller": "matches discovery"
|
|
},
|
|
"vlans": {
|
|
"discovery": {
|
|
"vlans": [
|
|
{
|
|
"vlan_vlan": 1,
|
|
"vlan_domain": 1,
|
|
"vlan_name": "default",
|
|
"vlan_type": null,
|
|
"vlan_mtu": null
|
|
},
|
|
{
|
|
"vlan_vlan": 10,
|
|
"vlan_domain": 1,
|
|
"vlan_name": "data",
|
|
"vlan_type": null,
|
|
"vlan_mtu": null
|
|
},
|
|
{
|
|
"vlan_vlan": 99,
|
|
"vlan_domain": 1,
|
|
"vlan_name": "mgmt",
|
|
"vlan_type": null,
|
|
"vlan_mtu": null
|
|
},
|
|
{
|
|
"vlan_vlan": 1000,
|
|
"vlan_domain": 1,
|
|
"vlan_name": "blackhole",
|
|
"vlan_type": null,
|
|
"vlan_mtu": null
|
|
}
|
|
],
|
|
"ports_vlans": [
|
|
{
|
|
"vlan": 1,
|
|
"baseport": 1,
|
|
"priority": 0,
|
|
"state": "unknown",
|
|
"cost": 0,
|
|
"untagged": 1
|
|
},
|
|
{
|
|
"vlan": 1,
|
|
"baseport": 2,
|
|
"priority": 0,
|
|
"state": "unknown",
|
|
"cost": 0,
|
|
"untagged": 1
|
|
},
|
|
{
|
|
"vlan": 1,
|
|
"baseport": 3,
|
|
"priority": 0,
|
|
"state": "unknown",
|
|
"cost": 0,
|
|
"untagged": 1
|
|
},
|
|
{
|
|
"vlan": 1,
|
|
"baseport": 4,
|
|
"priority": 0,
|
|
"state": "unknown",
|
|
"cost": 0,
|
|
"untagged": 1
|
|
},
|
|
{
|
|
"vlan": 1,
|
|
"baseport": 5,
|
|
"priority": 0,
|
|
"state": "unknown",
|
|
"cost": 0,
|
|
"untagged": 1
|
|
},
|
|
{
|
|
"vlan": 1,
|
|
"baseport": 6,
|
|
"priority": 0,
|
|
"state": "unknown",
|
|
"cost": 0,
|
|
"untagged": 1
|
|
},
|
|
{
|
|
"vlan": 1,
|
|
"baseport": 53,
|
|
"priority": 0,
|
|
"state": "unknown",
|
|
"cost": 0,
|
|
"untagged": 0
|
|
},
|
|
{
|
|
"vlan": 10,
|
|
"baseport": 4,
|
|
"priority": 0,
|
|
"state": "unknown",
|
|
"cost": 0,
|
|
"untagged": 1
|
|
},
|
|
{
|
|
"vlan": 10,
|
|
"baseport": 53,
|
|
"priority": 0,
|
|
"state": "unknown",
|
|
"cost": 0,
|
|
"untagged": 0
|
|
},
|
|
{
|
|
"vlan": 99,
|
|
"baseport": 4,
|
|
"priority": 0,
|
|
"state": "unknown",
|
|
"cost": 0,
|
|
"untagged": 1
|
|
},
|
|
{
|
|
"vlan": 99,
|
|
"baseport": 53,
|
|
"priority": 0,
|
|
"state": "unknown",
|
|
"cost": 0,
|
|
"untagged": 0
|
|
},
|
|
{
|
|
"vlan": 1000,
|
|
"baseport": 53,
|
|
"priority": 0,
|
|
"state": "unknown",
|
|
"cost": 0,
|
|
"untagged": 0
|
|
}
|
|
]
|
|
}
|
|
},
|
|
"stp": {
|
|
"discovery": {
|
|
"stp": [
|
|
{
|
|
"vlan": null,
|
|
"rootBridge": 0,
|
|
"bridgeAddress": "d4f527665ad0",
|
|
"protocolSpecification": "ieee8021d",
|
|
"priority": 0,
|
|
"timeSinceTopologyChange": "0",
|
|
"topChanges": 0,
|
|
"designatedRoot": "000000000000",
|
|
"rootCost": 0,
|
|
"rootPort": 0,
|
|
"maxAge": 20,
|
|
"helloTime": 2,
|
|
"holdTime": 1,
|
|
"forwardDelay": 15,
|
|
"bridgeMaxAge": 20,
|
|
"bridgeHelloTime": 2,
|
|
"bridgeForwardDelay": 15
|
|
}
|
|
]
|
|
},
|
|
"poller": "matches discovery"
|
|
}
|
|
}
|