* Extract DiscoveryItem and move some things to better places. Extract model class Fix up model construction. I have problem with construction... Makeshift model working. Switch constructor to factory. discover() and create() Support legacy discovery. Remove uneeded custom pollers Remove netonix custom detection as we try ucd on all os now. Add a few yaml procs. Fix a couple things. More processor discovery conversions Move Calix e7 to standard hrProcessorLoad, but it doesn't fully implement the HR-MIB, move things around to make it work. Add a few yaml procs. Fix a couple things. Correct some stupid mib stuff. Move more, drop php 5.3 Add netscaler which uses string indexes. Port fiberhome to yaml and use skip_values More conversions. BroadcomProcessorUsage Trait Serveriron and Ironware share some mibs. Create a common abstract os for them. Add yaml support for mib specification in each data entry Make legacy discover_processor() set 0 for hrDeviceIndex Untangle Dell switch OS processors Use use shared OS for groups if they don't have a specific group. fix silly mib mistake Make index optional Move HR and UCD to Traits and out of Processor. * forgot to update the fortiswitch index * Make sgos and avaya-ers match the old index. * fix comware test data * fix merge errors * fix dsm and remove pointless empty modules * file not found exception is in the wrong place. * Updated processor development docs
2845 lines
105 KiB
Plaintext
2845 lines
105 KiB
Plaintext
|
|
--
|
|
-- "@(#)fa.mib 00/07/07"
|
|
--
|
|
-- Title: Fibre Alliance Fibre Channel Management Framework Integration MIB
|
|
-- Rev 1.5, June 1, 1999.
|
|
--
|
|
-- Note: This is released for Brocade
|
|
--
|
|
-- Corrected revisionNumber description. last editor on Sept. 09, 2004
|
|
--
|
|
-- added FA MIB last edited on Dec. 18, 2000.
|
|
-- Last edit date: Sept. 09, 2004
|
|
|
|
FCMGMT-MIB DEFINITIONS ::= BEGIN
|
|
IMPORTS
|
|
IpAddress, TimeTicks, experimental
|
|
FROM RFC1155-SMI
|
|
OBJECT-TYPE
|
|
FROM RFC-1212
|
|
DisplayString
|
|
FROM RFC1213-MIB
|
|
TRAP-TYPE
|
|
FROM RFC-1215;
|
|
|
|
--Textual conventions for this MIB
|
|
|
|
FcNameId ::= OCTET STRING (SIZE(8))
|
|
|
|
FcGlobalId ::= OCTET STRING (SIZE(16))
|
|
|
|
FcAddressId ::= OCTET STRING (SIZE(3))
|
|
|
|
FcEventSeverity ::= INTEGER {
|
|
unknown (1),
|
|
emergency (2),
|
|
alert (3),
|
|
critical (4),
|
|
error (5),
|
|
warning (6),
|
|
notify (7),
|
|
info (8),
|
|
debug (9),
|
|
mark (10) -- All messages logged
|
|
}
|
|
|
|
FcUnitType ::= INTEGER {
|
|
unknown(1),
|
|
other(2), -- none of the following
|
|
hub(3), -- passive connectivity unit
|
|
-- supporting loop protocol.
|
|
switch(4), -- active connectivity unit
|
|
-- supporting multiple protocols.
|
|
gateway(5), -- unit that converts not only
|
|
-- the interface but also encapsulates
|
|
-- the frame into another protocol. The
|
|
-- assumption is that there is always
|
|
-- two gateways connected together. For
|
|
-- example, FC <-> ATM.
|
|
converter(6), -- unit that converts from one
|
|
-- interface to another. For
|
|
-- example, FC <-> SCSI.
|
|
hba(7), -- host bus adapter
|
|
proxy-agent(8), -- software proxy-agent
|
|
storage-device(9), -- disk,cd,tape,etc
|
|
host(10), -- host computer
|
|
storage-subsystem(11), -- raid, library, etc
|
|
module(12), -- subcomponent of a system
|
|
swdriver(13), -- software driver
|
|
storage-access-device(14), -- Provides storage management
|
|
-- and access for hetergeneous
|
|
-- hosts and heterogeneous devices.
|
|
wdm(15), -- waveform division mutiplexer
|
|
ups(16) -- uninterruptable power supply
|
|
}
|
|
|
|
|
|
|
|
|
|
|
|
----------------------------------------------------------------------
|
|
fcmgmt OBJECT IDENTIFIER ::= { experimental 94 }
|
|
|
|
-- groups in fcmgmt
|
|
|
|
connSet OBJECT IDENTIFIER ::= { fcmgmt 1 }
|
|
trapReg OBJECT IDENTIFIER ::= { fcmgmt 2 }
|
|
statSet OBJECT IDENTIFIER ::= { fcmgmt 4 }
|
|
connUnitServiceSet OBJECT IDENTIFIER ::= { fcmgmt 5 }
|
|
connUnitServiceScalars OBJECT IDENTIFIER ::= { connUnitServiceSet 1 }
|
|
connUnitServiceTables OBJECT IDENTIFIER ::= { connUnitServiceSet 2 }
|
|
|
|
revisionNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (4))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is the revision number for this MIB. The
|
|
format of the revision value is as follows
|
|
(0) = high order major revision number
|
|
(1) = low order major revision number
|
|
(2) = high order minor revision number
|
|
(3) = low order minor revision number
|
|
The value will be stored as an ASCII value. The
|
|
following is the current value of this object.
|
|
(0) = '0'
|
|
(1) = '3'
|
|
(2) = '0'
|
|
(3) = '0'
|
|
This defines a revision of 03.00
|
|
"
|
|
::= { fcmgmt 3 }
|
|
|
|
-- the connectivity unit group
|
|
|
|
-- Implementation of the group is mandatory for all systems.
|
|
|
|
uNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of connectivity units present on this
|
|
system (represented by this agent). May be a count
|
|
of the boards in a chassis or the number of full boxes
|
|
in a rack."
|
|
DEFVAL { 1 }
|
|
::= { connSet 1 }
|
|
|
|
systemURL OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The top-level URL of the system. If it does not exist
|
|
the value is empty string. The URL format is
|
|
implementation dependant and can have keywords embedded
|
|
that are preceeded by a percent sign (eg, %USER).
|
|
The following are the defined keywords that will
|
|
be recognized and replaced with data during a launch.
|
|
USER - replace with username
|
|
PASSWORD - replace with password
|
|
GLOBALID - replace with globalid
|
|
SERIALNO - replace with serial number
|
|
"
|
|
DEFVAL { "" }
|
|
::= { connSet 2 }
|
|
|
|
statusChangeTime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The sysuptime timestamp in centiseconds at which
|
|
the last status change occurred for any members of
|
|
the set."
|
|
::= { connSet 3 }
|
|
|
|
configurationChangeTime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The sysuptime timestamp in centiseconds at which
|
|
the last configuration change occurred for any
|
|
members of the set. This represents a union of change
|
|
information for connUnitConfigurationChangeTime."
|
|
::= { connSet 4 }
|
|
|
|
connUnitTableChangeTime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The sysuptime timestamp in centiseconds at which
|
|
the connUnitTable was updated (an entry was either
|
|
added or deleted."
|
|
::= { connSet 5 }
|
|
|
|
-- The Connectivity table contains general information on the
|
|
-- system's units.
|
|
connUnitTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ConnUnitEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of units under a single SNMP agent. The number
|
|
of entries is given by the value of uNumber. It is 1
|
|
for stand-alone system."
|
|
::= { connSet 6 }
|
|
|
|
connUnitEntry OBJECT-TYPE
|
|
SYNTAX ConnUnitEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A connectivity unit entry containing objects for a
|
|
particular unit."
|
|
INDEX { connUnitId }
|
|
::= { connUnitTable 1 }
|
|
|
|
ConnUnitEntry ::=
|
|
SEQUENCE {
|
|
connUnitId
|
|
OCTET STRING,
|
|
connUnitGlobalId
|
|
FcGlobalId,
|
|
connUnitType
|
|
FcUnitType,
|
|
connUnitNumports
|
|
INTEGER,
|
|
connUnitState
|
|
INTEGER,
|
|
connUnitStatus
|
|
INTEGER,
|
|
connUnitProduct
|
|
DisplayString,
|
|
connUnitSn
|
|
DisplayString,
|
|
connUnitUpTime
|
|
TimeTicks,
|
|
connUnitUrl
|
|
DisplayString,
|
|
connUnitDomainId
|
|
OCTET STRING,
|
|
connUnitProxyMaster
|
|
INTEGER,
|
|
connUnitPrincipal
|
|
INTEGER,
|
|
connUnitNumSensors
|
|
INTEGER,
|
|
connUnitStatusChangeTime
|
|
TimeTicks,
|
|
connUnitConfigurationChangeTime
|
|
TimeTicks,
|
|
connUnitNumRevs
|
|
INTEGER,
|
|
connUnitNumZones
|
|
INTEGER,
|
|
connUnitModuleId
|
|
OCTET STRING,
|
|
connUnitName
|
|
DisplayString,
|
|
connUnitInfo
|
|
DisplayString,
|
|
connUnitControl
|
|
INTEGER,
|
|
connUnitContact
|
|
DisplayString,
|
|
connUnitLocation
|
|
DisplayString,
|
|
connUnitEventFilter
|
|
FcEventSeverity,
|
|
connUnitNumEvents
|
|
INTEGER,
|
|
connUnitMaxEvents
|
|
INTEGER,
|
|
connUnitEventCurrID
|
|
INTEGER
|
|
}
|
|
|
|
connUnitId OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (16))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The unique identification for this connectivity unit
|
|
among those within this proxy domain.
|
|
The value MUST be unique within the proxy domain
|
|
because it is the index variable for connUnitTable.
|
|
The value assigned to a given conectivity unit
|
|
SHOULD be persistent across agent and unit resets.
|
|
It SHOULD be the same as connUnitGlobalId
|
|
if connUnitGlobalId is known and stable."
|
|
::= { connUnitEntry 1 }
|
|
|
|
connUnitGlobalId OBJECT-TYPE
|
|
SYNTAX FcGlobalId
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An optional global-scope identifier for this connectivity unit.
|
|
It MUST be a WWN for this connectivity unit
|
|
or 16 octets of value zero.
|
|
WWN formats requiring fewer than 16 octets
|
|
MUST be extended to 16 octets with trailing zero octets,
|
|
If a WWN is used for connUnitId,
|
|
the same WWN MUST be used for connUnitGlobalId.
|
|
When a non-zero value is provided,
|
|
it SHOULD be persistent across agent and unit resets.
|
|
It SHOULD be globally unique.
|
|
It SHOULD be one of these FC-PH/PH3 formats:
|
|
IEEE (NAA=1)
|
|
IEEE Extended (NAA=2)
|
|
IEEE Registered (NAA=5).
|
|
IEEE Registered extended (NAA=6).
|
|
|
|
Use of the IEEE formats allows any IEEE-registered vendor
|
|
to assure global uniqueness independently.
|
|
The following are some references on IEEE WWN formats:
|
|
http://standards.ieee.org/regauth/oui/tutorials/fibreformat.html
|
|
http://standards.ieee.org/regauth/oui/tutorials/fibrecomp_id.html
|
|
|
|
If one or more WWNs are associated with the connUnit
|
|
via other management methods,
|
|
one of them SHOULD be used for connUnitGlobalId.
|
|
If there is not a WWN assigned specifically to the connUnit,
|
|
there is some merit, though not a requirement,
|
|
to using a WWN assigned to (one of)
|
|
its permanently attached FC/LAN interface(s).
|
|
This can not risk uniqueness, though.
|
|
As a counterexample, if your
|
|
agent runs in a host and the host has an HBA,
|
|
it is quite possible that agent, host, and HBA
|
|
will all be distinct connUnits, so the host
|
|
and agent can not use the WWN of the HBA.
|
|
Another example:
|
|
If your hub has a built-in Ethernet port, it
|
|
might be reasonable for the hub to use its LAN
|
|
address (prefixed with the appropriate
|
|
NAA) as its connUnitId. But if the
|
|
Ethernet were a replaceable PCCard, the hub
|
|
should have an independent ID."
|
|
::= { connUnitEntry 2 }
|
|
|
|
connUnitType OBJECT-TYPE
|
|
SYNTAX FcUnitType
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of this connectivity unit."
|
|
::= { connUnitEntry 3 }
|
|
|
|
|
|
connUnitNumports OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of physical ports in the connectivity unit
|
|
(internal/embedded, external)."
|
|
::= { connUnitEntry 4 }
|
|
|
|
connUnitState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
online(2),
|
|
offline(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Overall state of the connectivity unit."
|
|
::= { connUnitEntry 5 }
|
|
|
|
connUnitStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
unused(2),
|
|
ok(3),
|
|
warning(4), -- needs attention
|
|
failed(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
|
|
DESCRIPTION
|
|
"Overall status of the connectivity unit."
|
|
::= { connUnitEntry 6 }
|
|
|
|
connUnitProduct OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..79))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The connectivity unit vendor's product
|
|
model name."
|
|
::= { connUnitEntry 7 }
|
|
|
|
connUnitSn OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..79))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The serial number for this connectivity unit."
|
|
::= { connUnitEntry 8 }
|
|
|
|
connUnitUpTime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of centiseconds since the
|
|
last unit initialization."
|
|
::= { connUnitEntry 9 }
|
|
|
|
connUnitUrl OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"URL to launch a management application,
|
|
if applicable. Otherwise empty string.
|
|
In a standalone unit, this would be the
|
|
same as the top-level URL. This has the same
|
|
definition as systemURL for keywords."
|
|
::= { connUnitEntry 10 }
|
|
|
|
connUnitDomainId OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(3))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"24 bit Fibre Channel address ID of this
|
|
connectivity unit, right justified with leading
|
|
zero's if required. This should be set to the
|
|
Fibre Channel address ID or if it is a switch
|
|
it would be set to the Domain Controller address.
|
|
If this value is not applicable,
|
|
return all bits set to one."
|
|
::= { connUnitEntry 11 }
|
|
|
|
connUnitProxyMaster OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
no(2),
|
|
yes(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A value of 'yes' means this is the proxy master
|
|
unit for a set of managed units. For example,
|
|
this could be the only unit with a management
|
|
card in it for a set of units. A standalone unit
|
|
should return 'yes' for this object."
|
|
::= { connUnitEntry 12 }
|
|
|
|
connUnitPrincipal OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
no(2),
|
|
yes(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Whether this connectivity unit is the principal unit
|
|
within the group of fabric elements. If this value
|
|
is not applicable, return unknown."
|
|
::= { connUnitEntry 13 }
|
|
|
|
connUnitNumSensors OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of sensors in the connUnitSensorTable."
|
|
::= { connUnitEntry 14 }
|
|
|
|
connUnitStatusChangeTime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The sysuptime timestamp in centiseconds
|
|
at which the last status change occurred."
|
|
::= { connUnitEntry 15 }
|
|
|
|
connUnitConfigurationChangeTime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The sysuptime timestamp in centiseconds
|
|
at which the last configuration change
|
|
occurred."
|
|
::= { connUnitEntry 16 }
|
|
|
|
connUnitNumRevs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of revisions in the connUnitRevsTable."
|
|
DEFVAL { 1 }
|
|
::= { connUnitEntry 17 }
|
|
|
|
connUnitNumZones OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Number of zones defined in connUnitZoneTable."
|
|
::= { connUnitEntry 18 }
|
|
|
|
connUnitModuleId OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(16))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is a unique id, persistent between boots,
|
|
that can be used to group a set of connUnits
|
|
together into a module. The intended use would
|
|
be to create a connUnit with a connUnitType of
|
|
'module' to represent a physical or logical
|
|
group of connectivity units. Then the value
|
|
of the group would be set to the value of
|
|
connUnitId for this 'container' connUnit.
|
|
connUnitModuleId should be zeros if this
|
|
connUnit is not part of a module."
|
|
::= { connUnitEntry 19 }
|
|
|
|
connUnitName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..79))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A display string containing a name for this
|
|
connectivity unit. This object value should be
|
|
persistent between boots."
|
|
::= { connUnitEntry 20 }
|
|
|
|
connUnitInfo OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A display string containing information
|
|
about this connectivity unit. This object value
|
|
should be persistent between boots."
|
|
::= { connUnitEntry 21 }
|
|
|
|
connUnitControl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
invalid(2),
|
|
resetConnUnitColdStart(3),
|
|
resetConnUnitWarmStart(4),
|
|
offlineConnUnit(5),
|
|
onlineConnUnit(6)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object is used to control the addressed
|
|
connUnit.
|
|
|
|
NOTE: 'Cold Start' and 'Warm Start'
|
|
are as defined in MIB II and are not meant
|
|
to be a factory reset.
|
|
|
|
resetConnUnitColdStart:
|
|
the addressed unit performs
|
|
a 'Cold Start' reset.
|
|
|
|
resetConnUnitWarmStart:
|
|
the addressed unit performs
|
|
a 'Warm Start' reset.
|
|
|
|
offlineConnUnit:
|
|
the addressed unit puts itself into
|
|
an implementation dependant 'offline' state.
|
|
In general,if a unit is in an offline state,
|
|
it cannot be used to perform meaningful
|
|
Fibre Channel work.
|
|
|
|
onlineConnUnit:
|
|
the addressed unit puts itself into an
|
|
implementation dependant 'online' state.
|
|
In general, if a unit is in an online state,
|
|
it is capable of performing meaningful
|
|
Fibre Channel work.
|
|
|
|
NOTE: Each implementation may chose not to allow
|
|
any or all of these values on a SET. "
|
|
|
|
::= { connUnitEntry 22 }
|
|
|
|
connUnitContact OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..79))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contact information for this connectivity
|
|
unit."
|
|
::= { connUnitEntry 23 }
|
|
|
|
connUnitLocation OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..79))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Location information for this connectivity
|
|
unit."
|
|
::= { connUnitEntry 24 }
|
|
|
|
connUnitEventFilter OBJECT-TYPE
|
|
SYNTAX FcEventSeverity
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value defines the event severity
|
|
that will be logged by this connectivity unit.
|
|
All events of severity less than or equal to
|
|
connUnitEventFilter are logged in connUnitEventTable."
|
|
::= { connUnitEntry 25 }
|
|
|
|
connUnitNumEvents OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of events currently in the
|
|
connUnitEventTable."
|
|
::= { connUnitEntry 26 }
|
|
|
|
connUnitMaxEvents OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Max number of events that can be defined
|
|
in connUnitEventTable."
|
|
::= { connUnitEntry 27 }
|
|
|
|
connUnitEventCurrID OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The last used event id (connUnitEventId)."
|
|
::= { connUnitEntry 28 }
|
|
|
|
|
|
------------------------------------------------------------------
|
|
-- The Table of revisions for hardware and software elements.
|
|
|
|
connUnitRevsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ConnUnitRevsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of the revisions supported by
|
|
connectivity units managed by this agent."
|
|
::= { connSet 7 }
|
|
|
|
connUnitRevsEntry OBJECT-TYPE
|
|
SYNTAX ConnUnitRevsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
INDEX { connUnitRevsUnitId,
|
|
connUnitRevsIndex }
|
|
::= { connUnitRevsTable 1 }
|
|
|
|
ConnUnitRevsEntry ::=
|
|
SEQUENCE {
|
|
connUnitRevsUnitId
|
|
OCTET STRING,
|
|
connUnitRevsIndex
|
|
INTEGER,
|
|
connUnitRevsRevId
|
|
DisplayString,
|
|
connUnitRevsDescription
|
|
DisplayString }
|
|
|
|
connUnitRevsUnitId OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (16))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The connUnitId of the connectivity unit
|
|
that contains this revision table."
|
|
::= { connUnitRevsEntry 1 }
|
|
|
|
connUnitRevsIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value among all connUnitRevsEntrys
|
|
with the same value of connUnitRevsUnitId,
|
|
in the range between 1 and
|
|
connUnitNumRevs[connUnitRevsUnitId]."
|
|
::= { connUnitRevsEntry 2 }
|
|
|
|
connUnitRevsRevId OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A vendor-specific string identifying a
|
|
revision of a component of the connUnit
|
|
indexed by connUnitRevsUnitId."
|
|
::= { connUnitRevsEntry 3 }
|
|
|
|
connUnitRevsDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of a component to which the revision
|
|
corresponds."
|
|
::= { connUnitRevsEntry 4 }
|
|
|
|
-----------------------------------------------------------------------
|
|
-- The Sensor table
|
|
|
|
connUnitSensorTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ConnUnitSensorEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of the sensors supported by each
|
|
connectivity unit managed by this agent."
|
|
::= { connSet 8 }
|
|
|
|
connUnitSensorEntry OBJECT-TYPE
|
|
SYNTAX ConnUnitSensorEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Each entry contains the information for a
|
|
specific sensor."
|
|
INDEX { connUnitSensorUnitId,
|
|
connUnitSensorIndex }
|
|
::= { connUnitSensorTable 1 }
|
|
|
|
ConnUnitSensorEntry ::=
|
|
SEQUENCE {
|
|
connUnitSensorUnitId
|
|
OCTET STRING,
|
|
connUnitSensorIndex
|
|
INTEGER,
|
|
connUnitSensorName
|
|
DisplayString,
|
|
connUnitSensorStatus
|
|
INTEGER,
|
|
connUnitSensorInfo
|
|
DisplayString,
|
|
connUnitSensorMessage
|
|
DisplayString,
|
|
connUnitSensorType
|
|
INTEGER,
|
|
connUnitSensorCharacteristic
|
|
INTEGER
|
|
}
|
|
|
|
connUnitSensorUnitId OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (16))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The connUnitId of the connectivity unit
|
|
that contains this sensor table."
|
|
::= { connUnitSensorEntry 1 }
|
|
|
|
connUnitSensorIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value among all connUnitSensorEntrys
|
|
with the same value of connUnitSensorUnitId,
|
|
in the range between 1 and
|
|
connUnitNumSensor[connUnitSensorUnitId]."
|
|
::= { connUnitSensorEntry 2}
|
|
|
|
connUnitSensorName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A textual identification of the sensor
|
|
intended primarily for operator use."
|
|
::= { connUnitSensorEntry 3 }
|
|
|
|
connUnitSensorStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
other(2),
|
|
ok(3), -- the sensor indicates ok
|
|
warning(4), -- the sensor indicates a warning
|
|
failed(5) -- the sensor indicates failure
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status indicated by the sensor."
|
|
::= { connUnitSensorEntry 4 }
|
|
|
|
connUnitSensorInfo OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Miscellaneous static info about the sensor
|
|
such as its serial number."
|
|
::= { connUnitSensorEntry 5 }
|
|
|
|
connUnitSensorMessage OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This describes the status of the sensor
|
|
as a message. It may also provide more
|
|
resolution on the sensor indication, for
|
|
example 'Cover temperature 1503K, above
|
|
nominal operating range'"
|
|
::= { connUnitSensorEntry 6 }
|
|
|
|
connUnitSensorType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
other(2),
|
|
battery(3),
|
|
fan(4),
|
|
power-supply(5),
|
|
transmitter(6),
|
|
enclosure(7),
|
|
board(8),
|
|
receiver(9)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of component being monitored by this
|
|
sensor."
|
|
::= { connUnitSensorEntry 7 }
|
|
|
|
connUnitSensorCharacteristic OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
other(2),
|
|
temperature(3),
|
|
pressure(4),
|
|
emf(5),
|
|
currentValue(6), -- current is a keyword
|
|
airflow(7),
|
|
frequency(8),
|
|
power(9),
|
|
door(10)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The characteristics being monitored by this
|
|
sensor."
|
|
::= { connUnitSensorEntry 8 }
|
|
|
|
-----------------------------------------------------------------------
|
|
-- The port table
|
|
|
|
connUnitPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ConnUnitPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Generic information on ports for a specific
|
|
connUnit."
|
|
::= { connSet 10 }
|
|
|
|
connUnitPortEntry OBJECT-TYPE
|
|
SYNTAX ConnUnitPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Each entry contains the information for
|
|
a specific port."
|
|
INDEX { connUnitPortUnitId,
|
|
connUnitPortIndex }
|
|
::= { connUnitPortTable 1 }
|
|
|
|
ConnUnitPortEntry ::=
|
|
SEQUENCE {
|
|
connUnitPortUnitId
|
|
OCTET STRING,
|
|
connUnitPortIndex
|
|
INTEGER,
|
|
connUnitPortType
|
|
INTEGER,
|
|
connUnitPortFCClassCap
|
|
OCTET STRING,
|
|
connUnitPortFCClassOp
|
|
OCTET STRING,
|
|
connUnitPortState
|
|
INTEGER,
|
|
connUnitPortStatus
|
|
INTEGER,
|
|
connUnitPortTransmitterType
|
|
INTEGER,
|
|
connUnitPortModuleType
|
|
INTEGER,
|
|
connUnitPortWwn
|
|
FcNameId,
|
|
connUnitPortFCId
|
|
OCTET STRING,
|
|
connUnitPortSn
|
|
DisplayString,
|
|
connUnitPortRevision
|
|
DisplayString,
|
|
connUnitPortVendor
|
|
DisplayString,
|
|
connUnitPortSpeed
|
|
INTEGER,
|
|
connUnitPortControl
|
|
INTEGER,
|
|
connUnitPortName
|
|
DisplayString,
|
|
connUnitPortPhysicalNumber
|
|
INTEGER,
|
|
connUnitPortStatObject
|
|
OBJECT IDENTIFIER,
|
|
connUnitPortProtocolCap
|
|
OCTET STRING,
|
|
connUnitPortProtocolOp
|
|
OCTET STRING,
|
|
connUnitPortNodeWwn
|
|
FcNameId,
|
|
connUnitPortHWState
|
|
INTEGER
|
|
}
|
|
|
|
connUnitPortUnitId OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (16))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The connUnitId of the connectivity unit
|
|
that contains this port."
|
|
::= { connUnitPortEntry 1 }
|
|
|
|
connUnitPortIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value among all connUnitPortEntrys
|
|
on this connectivity unit, between 0 and
|
|
connUnitNumPort[connUnitPortUnitId]."
|
|
::= { connUnitPortEntry 2 }
|
|
|
|
connUnitPortType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
other (2),
|
|
not-present (3),
|
|
hub-port (4),
|
|
n-port (5), -- end port for fabric
|
|
l-port (6), -- end port for loop
|
|
fl-port (7), -- public loop
|
|
f-port (8), -- fabric port
|
|
e-port (9), -- fabric expansion port
|
|
g-port (10), -- generic fabric port
|
|
domain-ctl (11), -- domain controller
|
|
hub-controller(12),
|
|
scsi (13), -- parallel SCSI port
|
|
escon (14),
|
|
lan (15),
|
|
wan (16),
|
|
ac (17), -- AC power line
|
|
dc (18), -- DC power line
|
|
ssa (19) -- serial storage architecture
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The port type."
|
|
::= { connUnitPortEntry 3 }
|
|
|
|
connUnitPortFCClassCap OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (2))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit mask that specifies the classes
|
|
of service capability of this port. If this is not
|
|
applicable, return all bits set to zero.
|
|
|
|
The bits have
|
|
the following definition:
|
|
unknown - 0
|
|
class-f - 1
|
|
class-one - 2
|
|
class-two - 4
|
|
class-three - 8
|
|
class-four - 16
|
|
class-five - 32
|
|
class-six - 64"
|
|
::= { connUnitPortEntry 4 }
|
|
|
|
connUnitPortFCClassOp OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (2))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit mask that specifies the classes
|
|
of service that are currently operational.
|
|
If this is not applicable, return all bits
|
|
set to zero. This object has the same
|
|
definition as connUnitPortFCClassCap"
|
|
::= { connUnitPortEntry 5 }
|
|
|
|
connUnitPortState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
online(2), -- available for meaningful work
|
|
offline(3), -- not available for meaningful work
|
|
bypassed(4), -- no longer used (4/12/00)
|
|
diagnostics(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The user selected state of the port hardware."
|
|
::= { connUnitPortEntry 6 }
|
|
|
|
connUnitPortStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
unused (2), -- device cannot report this status
|
|
ready (3), -- FCAL Loop or FCPH Link reset protocol
|
|
-- initialization has completed
|
|
warning (4), -- do not use (4/12/00)
|
|
failure (5), -- do not use (4/12/00)
|
|
notparticipating (6), -- loop notparticipating and does not
|
|
-- have a loop address
|
|
initializing (7), -- protocol is proceeding
|
|
bypass (8), -- do not use (4/12/00)
|
|
ols (9) -- FCP offline status
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An overall protocol status for the
|
|
port. This value of connUnitPortState is not
|
|
online, then this is reported Unknown."
|
|
::= { connUnitPortEntry 7 }
|
|
|
|
connUnitPortTransmitterType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
other(2),
|
|
unused(3),
|
|
shortwave(4),
|
|
longwave(5),
|
|
copper(6),
|
|
scsi(7),
|
|
longwaveNoOFC(8),
|
|
shortwaveNoOFC(9),
|
|
longwaveLED(10),
|
|
ssa(11)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The technology of the port transceiver."
|
|
::= { connUnitPortEntry 8 }
|
|
|
|
connUnitPortModuleType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
other(2),
|
|
gbic(3),
|
|
embedded(4), -- fixed, ie, oneXnine
|
|
glm(5),
|
|
gbicSerialId(6),
|
|
gbicNoSerialId(7),
|
|
gbicNotInstalled(8),
|
|
smallFormFactor(9)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The module type of the port connector."
|
|
::= { connUnitPortEntry 9 }
|
|
|
|
connUnitPortWwn OBJECT-TYPE
|
|
SYNTAX FcNameId
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The World Wide Name of the port
|
|
if applicable, otherwise empty string."
|
|
::= { connUnitPortEntry 10 }
|
|
|
|
connUnitPortFCId OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(3))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is the assigned Fibre Channel ID of
|
|
this port. This value is expected to be
|
|
a Big Endian value of 24 bits. If this is
|
|
loop, then it is the ALPA that is connected.
|
|
If this is an eport, then it will only
|
|
contain the domain ID left justified, zero
|
|
filled. If this port does not have a Fibre
|
|
Channel address, return all bits set to 1."
|
|
::= { connUnitPortEntry 11 }
|
|
|
|
connUnitPortSn OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..79))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The serial number of the unit (e.g., for
|
|
a GBIC). If this is not applicable, return
|
|
empty string."
|
|
::= { connUnitPortEntry 12 }
|
|
|
|
connUnitPortRevision OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..79))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The port revision (e.g., for a GBIC)."
|
|
::= { connUnitPortEntry 13 }
|
|
|
|
connUnitPortVendor OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..79))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The port vendor (e.g., for a GBIC)."
|
|
::= { connUnitPortEntry 14 }
|
|
|
|
connUnitPortSpeed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The speed of the port in kilobytes per
|
|
second."
|
|
::= { connUnitPortEntry 15 }
|
|
|
|
connUnitPortControl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
invalid(2),
|
|
resetConnUnitPort(3),
|
|
bypassConnUnitPort(4),
|
|
unbypassConnUnitPort(5),
|
|
offlineConnUnitPort(6),
|
|
onlineConnUnitPort(7),
|
|
resetConnUnitPortCounters(8)
|
|
}
|
|
ACCESS read-write -- (or maybe write-only)
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object is used to control the addressed
|
|
connUnit's port. Valid commands are:
|
|
|
|
resetConnUnitPort: If the addressed connUnit
|
|
allows this operation to be performed to this
|
|
port, the addressed port performs a
|
|
vendor-specific 'reset' operation. Examples of
|
|
these operations are: the Link Reset protocol,
|
|
the Loop Initialization protocol, or a
|
|
resynchronization occurring between the
|
|
transceiver in the addressed port to the
|
|
transceiver that the port is connected to.
|
|
|
|
bypassConnUnitPort: If the addressed connUnit
|
|
allows this operation to be performed to this
|
|
port, the addressed port performs a
|
|
vendor-specific 'bypass' operation. Examples of
|
|
these operations are:
|
|
transitioning from online to offline, a
|
|
request(NON-PARTICIPATING) command to the
|
|
Loop Port state machine, or removal of the
|
|
port from an arbitrated loop by a hub.
|
|
|
|
unbypassConnUnitPort: If the addressed connUnit
|
|
allows this operation to be performed to this
|
|
port, the addressed port performs a
|
|
vendor-specific 'unbypass' operation. Examples
|
|
of these operations are:
|
|
the Link Failure protocol, a
|
|
request(PARTICIPATING) command to the
|
|
Loop Port state machine, or addition of the
|
|
port to an arbitrated loop by a hub.
|
|
|
|
offlineConnUnitPort: If the addressed connUnit
|
|
allows this operation to be performed to this
|
|
port, the addressed port performs a
|
|
vendor-specific 'offline' operation. Examples
|
|
of these operations are:
|
|
disabling a port's transceiver, the Link
|
|
Failure protocol, request(NON-PARTICIPATING)
|
|
command to the Loop Port state machine, or
|
|
removal of the port from an arbitrated loop
|
|
by a hub.
|
|
|
|
onlineConnUnitPort: If the addressed connUnit
|
|
allows this operation to be performed to this
|
|
port, the addressed port performs a
|
|
vendor-specific 'online' operation. Examples
|
|
of these operations are:
|
|
enabling a port's transceiver, the Link
|
|
Failure protocol, request(PARTICIPATING)
|
|
command to the Loop Port state machine, or
|
|
addition of the port from an arbitrated loop
|
|
by a hub.
|
|
|
|
NOTE: Each implementation may chose not to allow
|
|
any or all of these values on a SET. "
|
|
|
|
::= { connUnitPortEntry 16 }
|
|
|
|
connUnitPortName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A string describing the addressed port."
|
|
::= { connUnitPortEntry 17 }
|
|
|
|
connUnitPortPhysicalNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is the internal port number this
|
|
port is known by. In many implementations,
|
|
this should be the same as connUnitPortIndex.
|
|
Some implementations may have an internal port
|
|
representation not compatible with the rules
|
|
for table indeces. In that case, provide the
|
|
internal representation of this port in this
|
|
object. This value may also be used in the
|
|
connUnitLinkPortNumberX or connUnitLinkPortNumberY
|
|
objects of the connUnitLinkTable."
|
|
::= { connUnitPortEntry 18 }
|
|
|
|
connUnitPortStatObject OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"This contains the OID of the first object of the
|
|
table that contains the statistics for this particular
|
|
port. If this has a value of zero, then there are no
|
|
statistics available for this port. The port type
|
|
information will help identify the statistics objects
|
|
that will be found in the table. From this point, one
|
|
would do a getnext to get the next statistics object.
|
|
When the first part of the OID changes, the end of
|
|
table is reached."
|
|
::= { connUnitPortEntry 19 }
|
|
|
|
connUnitPortProtocolCap OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (2))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit mask that specifies the driver level
|
|
protocol capability of this port. If this is not
|
|
applicable, return all bits set to zero.
|
|
|
|
The bits have
|
|
the following definition:
|
|
unknown - 0
|
|
Loop - 1
|
|
Fabric - 2
|
|
SCSI - 4
|
|
TCP/IP - 8
|
|
VI - 16
|
|
FICON - 32"
|
|
::= { connUnitPortEntry 20 }
|
|
|
|
connUnitPortProtocolOp OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (2))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit mask that specifies the driver level
|
|
protocol(s) that are currently operational.
|
|
If this is not applicable, return all bits
|
|
set to zero. This object has the same
|
|
definition as connUnitPortProtocolCap"
|
|
::= { connUnitPortEntry 21 }
|
|
|
|
connUnitPortNodeWwn OBJECT-TYPE
|
|
SYNTAX FcNameId
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Node World Wide Name of the port
|
|
if applicable, otherwise all zeros.
|
|
This should have the same value for a
|
|
group of related ports. The container is
|
|
defined as the largest physical entity.
|
|
For example, all ports on HBAs on a host
|
|
will have the same Node WWN. All ports on
|
|
the same storage subsystem will have the
|
|
same Node WWN."
|
|
::= { connUnitPortEntry 22 }
|
|
|
|
connUnitPortHWState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
failed (2), -- port failed diagnostics
|
|
bypassed (3), -- FCAL bypass, loop only
|
|
active (4), -- connected to a device
|
|
loopback (5), -- Port in ext loopback
|
|
txfault (6), -- Transmitter fault
|
|
noMedia (7), -- media not installed
|
|
linkDown (8) -- waiting for activity (rx sync)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The hardware detected state of the port."
|
|
::= { connUnitPortEntry 23 }
|
|
|
|
|
|
-----------------------------------------------------------------------
|
|
-- event group
|
|
|
|
connUnitEventTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ConnUnitEventEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The table of connectivity unit events. Errors,
|
|
warnings, and information should be reported
|
|
in this table."
|
|
::= { connSet 11 }
|
|
|
|
connUnitEventEntry OBJECT-TYPE
|
|
SYNTAX ConnUnitEventEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Each entry contains information on
|
|
a specific event for the given
|
|
connectivity unit."
|
|
INDEX { connUnitEventUnitId, connUnitEventIndex }
|
|
::= { connUnitEventTable 1 }
|
|
|
|
ConnUnitEventEntry ::=
|
|
SEQUENCE {
|
|
connUnitEventUnitId
|
|
OCTET STRING,
|
|
connUnitEventIndex
|
|
INTEGER,
|
|
connUnitEventId
|
|
INTEGER,
|
|
connUnitREventTime
|
|
DisplayString,
|
|
connUnitSEventTime
|
|
TimeTicks,
|
|
connUnitEventSeverity
|
|
FcEventSeverity,
|
|
connUnitEventType
|
|
INTEGER,
|
|
connUnitEventObject
|
|
OBJECT IDENTIFIER,
|
|
connUnitEventDescr
|
|
DisplayString
|
|
}
|
|
|
|
connUnitEventUnitId OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (16))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The connUnitId of the connectivity unit
|
|
that contains this event table."
|
|
::= { connUnitEventEntry 1 }
|
|
|
|
connUnitEventIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Each connectivity unit has its own event buffer.
|
|
As it wraps, it may write over previous events.
|
|
This object is an index into the buffer.
|
|
It is recommended that this table be read using
|
|
'getNext's to retrieve the initial table.
|
|
The management application should read the
|
|
event table at periodic intervals and then
|
|
determine if any new entries were added by
|
|
comparing the last known index value with the
|
|
current highest index value. The management
|
|
application should then update its copy of
|
|
the event table. If the read interval
|
|
is too long, it is possible that there may
|
|
be events that may not be contained in the
|
|
agent's internal event buffer.
|
|
For example, an agent may read events 50-75.
|
|
At the next read interval, connUnitEventCurrID
|
|
is 189. If the management app tries to read
|
|
event index 76, and the agent's internal buffer
|
|
is 100 entries max, event index 76 will no longer
|
|
be available.
|
|
The index value is an incrementing integer starting
|
|
from one every time there is a table reset.
|
|
On table reset, all contents are emptied and
|
|
all indeces are set to zero. When an
|
|
event is added to the table, the event is
|
|
assigned the next higher integer value than
|
|
the last item entered into the table. If the
|
|
index value reaches its maximum value, the next
|
|
item entered will cause the index value to
|
|
roll over and start at one again."
|
|
::= { connUnitEventEntry 2 }
|
|
|
|
connUnitEventId OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The internal event Id. Incremented for each
|
|
event, ranging between 0 and connUnitMaxEvents.
|
|
Not used as table index to simplify
|
|
the agent implementation. When this
|
|
reaches the end of the range specified by
|
|
connUnitMaxEvents, the Id will roll over to start
|
|
at zero. This value will be set back to zero at
|
|
reset. The relationship of this value to the index
|
|
is that internal event id may represent a smaller
|
|
number than a 32 bit integer (eg max 100 entries)
|
|
and would only have a value range up to
|
|
connUnitMaxEvents."
|
|
::= { connUnitEventEntry 3 }
|
|
|
|
connUnitREventTime OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (15))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is the real time when the event occurred.
|
|
It has the following format.
|
|
DDMMYYYY HHMMSS
|
|
DD=day number
|
|
MM=month number
|
|
YYYY=year number
|
|
HH=hour number
|
|
MM=minute number
|
|
SS=seconds number
|
|
If not applicable, return a NULL string."
|
|
::= { connUnitEventEntry 4 }
|
|
|
|
connUnitSEventTime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is the sysuptime timestamp when the
|
|
event occurred."
|
|
::= { connUnitEventEntry 5 }
|
|
|
|
connUnitEventSeverity OBJECT-TYPE
|
|
SYNTAX FcEventSeverity
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The event severity level."
|
|
::= { connUnitEventEntry 6 }
|
|
|
|
connUnitEventType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
other(2),
|
|
status(3),
|
|
configuration(4),
|
|
topology(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of this event."
|
|
::= { connUnitEventEntry 7 }
|
|
|
|
connUnitEventObject OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is used with the connUnitEventType
|
|
to identify which object the event refers to.
|
|
It can be the OID of a connectivity unit or of
|
|
another object like connUnitPortStatus[...]"
|
|
::= { connUnitEventEntry 8 }
|
|
|
|
connUnitEventDescr OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The description of the event."
|
|
::= { connUnitEventEntry 9 }
|
|
|
|
-- The link table
|
|
-- is intended to organize and communicate
|
|
-- any information the agent possesses
|
|
-- which would assist a management application
|
|
-- to discover the CONNECTIVITY UNITS in the
|
|
-- framework and the TOPOLOGY of their interconnect.
|
|
-- That is, the goal is to assist the management
|
|
-- application not only to LIST the elements of the framework,
|
|
-- but to MAP them.
|
|
|
|
-- With this goal, the agent SHOULD include
|
|
-- as much as it possesses about any links
|
|
-- from its own connectivity units to others,
|
|
-- including links among its own units.
|
|
|
|
-- An agent SHOULD include partial information
|
|
-- about links if it is not able to fully
|
|
-- define them in accord with the following structure;
|
|
-- however, the information MUST include either
|
|
-- a nonzero connUnitNodeId- or a nonzero connUnitPortWwn-
|
|
-- for each end of the link.
|
|
|
|
-- If the agent is able to discover links
|
|
-- which do not directly attach to members of its agency
|
|
-- and its discovery algorithm gives some assurance
|
|
-- the links are recently valid, it MAY include these links.
|
|
|
|
-- Link information entered by administrative action
|
|
-- MAY be included even if not validated directly
|
|
-- if the link has at least one endpoint in this agency,
|
|
-- but SHOULD NOT be included otherwise.
|
|
|
|
-- A connectivity unit should fill the table in as best it can.
|
|
-- One of the methods to fill this in would be to use the RNID
|
|
-- ELS (ANSI document 99-422v0). This allows one to query a
|
|
-- port for the information needed for the link table.
|
|
|
|
-- This table is accessed either directly if the management
|
|
-- software has an index value or via GetNexts. The value of
|
|
-- the indexes are not required to be contiguous. Each entry
|
|
-- created in this table will be assigned an index. This
|
|
-- relationship is kept persistent until the entry is removed
|
|
-- from the table or the system is reset. The total number of
|
|
-- entries are defined by the size of the table
|
|
|
|
-- For an entry to be considered to be valid, both the X (local)
|
|
-- and the Y (remote) need to have one valid value.
|
|
|
|
connUnitLinkTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ConnUnitLinkEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of links know to this agent from this
|
|
connectivity unit to other connectivity units."
|
|
::= { connSet 12 }
|
|
|
|
connUnitLinkEntry OBJECT-TYPE
|
|
SYNTAX ConnUnitLinkEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry describing a particular link to another."
|
|
INDEX { connUnitLinkUnitId,
|
|
connUnitLinkIndex }
|
|
::= { connUnitLinkTable 1 }
|
|
|
|
ConnUnitLinkEntry ::=
|
|
SEQUENCE {
|
|
connUnitLinkUnitId
|
|
OCTET STRING,
|
|
connUnitLinkIndex
|
|
INTEGER,
|
|
connUnitLinkNodeIdX
|
|
OCTET STRING,
|
|
connUnitLinkPortNumberX
|
|
INTEGER,
|
|
connUnitLinkPortWwnX
|
|
OCTET STRING,
|
|
connUnitLinkNodeIdY
|
|
OCTET STRING,
|
|
connUnitLinkPortNumberY
|
|
INTEGER,
|
|
connUnitLinkPortWwnY
|
|
OCTET STRING,
|
|
connUnitLinkAgentAddressY
|
|
OCTET STRING,
|
|
connUnitLinkAgentAddressTypeY
|
|
INTEGER,
|
|
connUnitLinkAgentPortY
|
|
INTEGER,
|
|
connUnitLinkUnitTypeY
|
|
FcUnitType,
|
|
connUnitLinkConnIdY
|
|
OCTET STRING,
|
|
connUnitLinkCurrIndex
|
|
INTEGER
|
|
}
|
|
|
|
connUnitLinkUnitId OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (16))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The connUnitId of the connectivity unit
|
|
that contains this link table."
|
|
::= { connUnitLinkEntry 1 }
|
|
|
|
connUnitLinkIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value is used to create a unique value
|
|
for each entry in the link table with the same
|
|
connUnitLinkUnitId. The value
|
|
can only be reused if it is not currently in
|
|
in use and the value is the next candidate to
|
|
be used. This value is allowed to wrap at the
|
|
highest value represented by the number of bits.
|
|
This value is reset to zero when the system is
|
|
Reset and the first value to be used is one."
|
|
::= { connUnitLinkEntry 2 }
|
|
|
|
connUnitLinkNodeIdX OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The node WWN of the unit at one end
|
|
of the link. If the node WWN is unknown
|
|
and the node is a connUnit in the responding
|
|
agent then the value of this object MUST BE
|
|
equal to its connUnitID."
|
|
::= { connUnitLinkEntry 3 }
|
|
|
|
connUnitLinkPortNumberX OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The port number on the unit specified by
|
|
connUnitLinkNodeIdX if known, otherwise -1.
|
|
If the value is nonnegative then it will be
|
|
equal to connUnitPortPhysicalNumber."
|
|
::= { connUnitLinkEntry 4 }
|
|
|
|
connUnitLinkPortWwnX OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(16))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The port WWN of the unit specified by
|
|
connUnitLinkNodeIdX if known,
|
|
otherwise 16 octets of binary 0"
|
|
::= { connUnitLinkEntry 5 }
|
|
|
|
connUnitLinkNodeIdY OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The node WWN of the unit at the other end
|
|
of the link. If the node WWN is unknown
|
|
and the node is a connUnit in the responding
|
|
SNMP agency then the value of this object
|
|
MUST BE equal to its connUnitID."
|
|
::= { connUnitLinkEntry 6 }
|
|
|
|
connUnitLinkPortNumberY OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The port number on the unit specified by
|
|
connUnitLinkNodeIdY if known, otherwise -1.
|
|
If the value is nonnegative then it will be
|
|
equal to connUnitPortPhysicalNumber."
|
|
::= { connUnitLinkEntry 7 }
|
|
|
|
connUnitLinkPortWwnY OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(16))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The port WWN on the unit specified by
|
|
connUnitLinkNodeIdY if known,
|
|
otherwise 16 octets of binary 0"
|
|
::= { connUnitLinkEntry 8 }
|
|
|
|
connUnitLinkAgentAddressY OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(16))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The address of an FCMGMT MIB agent for the
|
|
node identified by connUnitLinkNodeIdY,
|
|
if known; otherwise 16 octets of binary 0"
|
|
::= { connUnitLinkEntry 9 }
|
|
|
|
connUnitLinkAgentAddressTypeY OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If connUnitLinkAgentAddressY is nonzero,
|
|
it is a protocol address.
|
|
ConnUnitLinkAgentAddressTypeY is the
|
|
the 'address family number' assigned by IANA
|
|
to identify the address format.
|
|
(eg, 1 is Ipv4, 2 is Ipv6)."
|
|
::= { connUnitLinkEntry 10 }
|
|
|
|
connUnitLinkAgentPortY OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IP port number for the agent. This is
|
|
provided in case the agent is at a non-standard
|
|
SNMP port."
|
|
::= { connUnitLinkEntry 11 }
|
|
|
|
connUnitLinkUnitTypeY OBJECT-TYPE
|
|
SYNTAX FcUnitType
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Type of the FC connectivity unit as defined in
|
|
connUnitType."
|
|
::= { connUnitLinkEntry 12 }
|
|
|
|
connUnitLinkConnIdY OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(3))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This is the Fibre Channel ID of this port.
|
|
If the connectivity unit is a switch, this
|
|
is expected to be a Big Endian value of 24
|
|
bits. If this is loop, then it is the ALPA
|
|
that is connected. If this is an eport, then
|
|
it will only contain the domain ID. If not
|
|
any of those, unknown or cascaded loop,
|
|
return all bits set to 1."
|
|
::= { connUnitLinkEntry 13 }
|
|
|
|
connUnitLinkCurrIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The last used link index."
|
|
::= { connUnitLinkEntry 14 }
|
|
|
|
|
|
------------------------------------------------------------------
|
|
-- The following four tables have been obsoleted. These were used to
|
|
-- keep statistic information based on the type of port type. It was
|
|
-- changed for all ports to use a common statistics table.
|
|
|
|
-- Hub Port Statistics
|
|
|
|
-- connUnitPortStatHubTable OBJECT-TYPE
|
|
-- SYNTAX SEQUENCE OF ConnUnitPortStatHubEntry
|
|
-- ACCESS not-accessible
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "A list of statistics for the hub port type.
|
|
|
|
-- This object has been obsoleted."
|
|
-- ::= { statSet 1 }
|
|
|
|
|
|
-- Fabric Port Statistics
|
|
|
|
-- connUnitPortStatFabricTable OBJECT-TYPE
|
|
-- SYNTAX SEQUENCE OF ConnUnitPortStatFabricEntry
|
|
-- ACCESS not-accessible
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "A list of statistics for the fabric port types.
|
|
|
|
-- This object has been obsoleted."
|
|
-- ::= { statSet 2 }
|
|
|
|
-- SCSI Port Statistics
|
|
|
|
-- connUnitPortStatSCSITable OBJECT-TYPE
|
|
-- SYNTAX SEQUENCE OF ConnUnitPortStatSCSIEntry
|
|
-- ACCESS not-accessible
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "A list of statistics for the SCSI port type.
|
|
|
|
-- This object has been obsoleted."
|
|
-- ::= { statSet 3 }
|
|
|
|
-- LAN/WAN Port Statistics
|
|
|
|
-- connUnitPortStatLANTable OBJECT-TYPE
|
|
-- SYNTAX SEQUENCE OF ConnUnitPortStatLANEntry
|
|
-- ACCESS not-accessible
|
|
-- STATUS obsolete
|
|
-- DESCRIPTION
|
|
-- "A list of statistics for the LAN/WAN port type.
|
|
|
|
-- This object has been obsoleted."
|
|
-- ::= { statSet 4 }
|
|
|
|
|
|
|
|
-- There is one and only one statistics table for each
|
|
-- individual port. For all objects in statistics table, if the object is not
|
|
-- supported by the conn unit then the high order bit is set to 1 with all other
|
|
-- bits set to zero. The high order bit is reserved to indicate if the object
|
|
-- if supported or not. All objects start at a value of zero at hardware
|
|
-- initialization and continue incrementing till end of 63 bits and then
|
|
-- wrap to zero.
|
|
|
|
-- Port Statistics
|
|
|
|
connUnitPortStatTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ConnUnitPortStatEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of statistics for the fabric port types."
|
|
::= { statSet 5 }
|
|
|
|
connUnitPortStatEntry OBJECT-TYPE
|
|
SYNTAX ConnUnitPortStatEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An entry describing port statistics."
|
|
INDEX { connUnitPortStatUnitId,
|
|
connUnitPortStatIndex }
|
|
::= { connUnitPortStatTable 1 }
|
|
|
|
ConnUnitPortStatEntry ::=
|
|
SEQUENCE {
|
|
connUnitPortStatUnitId
|
|
FcGlobalId,
|
|
connUnitPortStatIndex
|
|
INTEGER,
|
|
connUnitPortStatCountError
|
|
OCTET STRING,
|
|
connUnitPortStatCountTxObjects
|
|
OCTET STRING,
|
|
connUnitPortStatCountRxObjects
|
|
OCTET STRING,
|
|
connUnitPortStatCountTxElements
|
|
OCTET STRING,
|
|
connUnitPortStatCountRxElements
|
|
OCTET STRING,
|
|
connUnitPortStatCountBBCreditZero
|
|
OCTET STRING,
|
|
connUnitPortStatCountInputBuffersFull
|
|
OCTET STRING,
|
|
connUnitPortStatCountFBSYFrames
|
|
OCTET STRING,
|
|
connUnitPortStatCountPBSYFrames
|
|
OCTET STRING,
|
|
connUnitPortStatCountFRJTFrames
|
|
OCTET STRING,
|
|
connUnitPortStatCountPRJTFrames
|
|
OCTET STRING,
|
|
connUnitPortStatCountClass1RxFrames
|
|
OCTET STRING,
|
|
connUnitPortStatCountClass1TxFrames
|
|
OCTET STRING,
|
|
connUnitPortStatCountClass1FBSYFrames
|
|
OCTET STRING,
|
|
connUnitPortStatCountClass1PBSYFrames
|
|
OCTET STRING,
|
|
connUnitPortStatCountClass1FRJTFrames
|
|
OCTET STRING,
|
|
connUnitPortStatCountClass1PRJTFrames
|
|
OCTET STRING,
|
|
connUnitPortStatCountClass2RxFrames
|
|
OCTET STRING,
|
|
connUnitPortStatCountClass2TxFrames
|
|
OCTET STRING,
|
|
connUnitPortStatCountClass2FBSYFrames
|
|
OCTET STRING,
|
|
connUnitPortStatCountClass2PBSYFrames
|
|
OCTET STRING,
|
|
connUnitPortStatCountClass2FRJTFrames
|
|
OCTET STRING,
|
|
connUnitPortStatCountClass2PRJTFrames
|
|
OCTET STRING,
|
|
connUnitPortStatCountClass3RxFrames
|
|
OCTET STRING,
|
|
connUnitPortStatCountClass3TxFrames
|
|
OCTET STRING,
|
|
connUnitPortStatCountClass3Discards
|
|
OCTET STRING,
|
|
connUnitPortStatCountRxMulticastObjects
|
|
OCTET STRING,
|
|
connUnitPortStatCountTxMulticastObjects
|
|
OCTET STRING,
|
|
connUnitPortStatCountRxBroadcastObjects
|
|
OCTET STRING,
|
|
connUnitPortStatCountTxBroadcastObjects
|
|
OCTET STRING,
|
|
connUnitPortStatCountRxLinkResets
|
|
OCTET STRING,
|
|
connUnitPortStatCountTxLinkResets
|
|
OCTET STRING,
|
|
connUnitPortStatCountNumberLinkResets
|
|
OCTET STRING,
|
|
connUnitPortStatCountRxOfflineSequences
|
|
OCTET STRING,
|
|
connUnitPortStatCountTxOfflineSequences
|
|
OCTET STRING,
|
|
connUnitPortStatCountNumberOfflineSequences
|
|
OCTET STRING,
|
|
connUnitPortStatCountLinkFailures
|
|
OCTET STRING,
|
|
connUnitPortStatCountInvalidCRC
|
|
OCTET STRING,
|
|
connUnitPortStatCountInvalidTxWords
|
|
OCTET STRING,
|
|
connUnitPortStatCountPrimitiveSequenceProtocolErrors
|
|
OCTET STRING,
|
|
connUnitPortStatCountLossofSignal
|
|
OCTET STRING,
|
|
connUnitPortStatCountLossofSynchronization
|
|
OCTET STRING,
|
|
connUnitPortStatCountInvalidOrderedSets
|
|
OCTET STRING,
|
|
connUnitPortStatCountFramesTooLong
|
|
OCTET STRING,
|
|
connUnitPortStatCountFramesTruncated
|
|
OCTET STRING,
|
|
connUnitPortStatCountAddressErrors
|
|
OCTET STRING,
|
|
connUnitPortStatCountDelimiterErrors
|
|
OCTET STRING,
|
|
connUnitPortStatCountEncodingDisparityErrors
|
|
OCTET STRING
|
|
}
|
|
|
|
connUnitPortStatUnitId OBJECT-TYPE
|
|
SYNTAX FcGlobalId
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The connUnitId of the connectivity unit
|
|
that contains this port stat table."
|
|
::= { connUnitPortStatEntry 1 }
|
|
|
|
connUnitPortStatIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value among all entrys
|
|
in this table, between 0 and
|
|
connUnitNumPort[connUnitPortUnitId]."
|
|
::= { connUnitPortStatEntry 2 }
|
|
|
|
connUnitPortStatCountError OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A count of the errors that have occured
|
|
on this port."
|
|
::= { connUnitPortStatEntry 3 }
|
|
|
|
connUnitPortStatCountTxObjects OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of frames/packets/IOs/etc that have been transmitted
|
|
by this port. Note: A Fibre Channel frame starts with SOF and
|
|
ends with EOF. FC loop devices should not count frames passed
|
|
through. This value represents the sum total for all other Tx
|
|
objects."
|
|
::= { connUnitPortStatEntry 4 }
|
|
|
|
connUnitPortStatCountRxObjects OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of frames/packets/IOs/etc that have been received
|
|
by this port. Note: A Fibre Channel frame starts with SOF and
|
|
ends with EOF. FC loop devices should not count frames passed
|
|
through. This value represents the sum total for all other Rx
|
|
objects."
|
|
::= { connUnitPortStatEntry 5 }
|
|
|
|
connUnitPortStatCountTxElements OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of octets or bytes that have been transmitted
|
|
by this port. One second periodic polling of the port. This
|
|
value is saved and compared with the next polled value to
|
|
compute net throughput. Note, for Fibre Channel, ordered
|
|
sets are not included in the count."
|
|
::= { connUnitPortStatEntry 6 }
|
|
|
|
connUnitPortStatCountRxElements OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of octets or bytes that have been received.
|
|
by this port. One second periodic polling of the port. This
|
|
value is saved and compared with the next polled value to
|
|
compute net throughput. Note, for Fibre Channel, ordered
|
|
sets are not included in the count."
|
|
::= { connUnitPortStatEntry 7 }
|
|
|
|
connUnitPortStatCountBBCreditZero OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Count of transitions in/out of BBcredit zero state.
|
|
The other side is not providing any credit. Note,
|
|
this is a Fibre Channel stat only."
|
|
::= { connUnitPortStatEntry 8 }
|
|
|
|
connUnitPortStatCountInputBuffersFull OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Count of occurrences when all input buffers of a
|
|
port were full and outbound buffer-to-buffer credit
|
|
transitioned to zero. There is no credit to
|
|
provide to other side. Note, this is a Fibre Channel
|
|
stat only."
|
|
::= { connUnitPortStatEntry 9 }
|
|
|
|
connUnitPortStatCountFBSYFrames OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Count of times that FBSY was returned to this port as a
|
|
result of a frame that could not be delivered to the other
|
|
end of the link. This occurs if either the Fabric or the
|
|
destination port is temporarily busy. Port can only occur
|
|
on SOFc1 frames (the frames that establish a connection).
|
|
Note, this is a Fibre Channel only stat. This is the sum
|
|
of all classes. If you cannot keep the by class counters,
|
|
then keep the sum counters."
|
|
::= { connUnitPortStatEntry 10 }
|
|
|
|
connUnitPortStatCountPBSYFrames OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Count of times that PBSY was returned to this port as a
|
|
result of a frame that could not be delivered to the other
|
|
end of the link. This occurs if the destination port is
|
|
temporarily busy. PBSY can only occur on SOFc1 frames
|
|
(the frames that establish a connection). Note, this is
|
|
a Fibre Channel only stat.This is the sum
|
|
of all classes. If you cannot keep the by class counters,
|
|
then keep the sum counters."
|
|
::= { connUnitPortStatEntry 11 }
|
|
|
|
connUnitPortStatCountFRJTFrames OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Count of times that FRJT was returned to this port as a
|
|
result of a Frame that was rejected by the fabric. Note,
|
|
This is the total for all classes and is a Fibre Channel
|
|
only stat."
|
|
::= { connUnitPortStatEntry 12 }
|
|
|
|
connUnitPortStatCountPRJTFrames OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Count of times that FRJT was returned to this port as a
|
|
result of a Frame that was rejected at the destination
|
|
N_Port. Note, This is the total for all classes and is
|
|
a Fibre Channel only stat."
|
|
::= { connUnitPortStatEntry 13 }
|
|
|
|
connUnitPortStatCountClass1RxFrames OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Count of Class 1 Frames received at this port. Note, this
|
|
is a Fibre Channel only stat."
|
|
::= { connUnitPortStatEntry 14 }
|
|
|
|
connUnitPortStatCountClass1TxFrames OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Count of Class 1 Frames transmitted out this port. Note,
|
|
this is a Fibre Channel only stat."
|
|
::= { connUnitPortStatEntry 15 }
|
|
|
|
connUnitPortStatCountClass1FBSYFrames OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Count of times that FBSY was returned to this port as a
|
|
result of a Class 1 Frame that could not be delivered to the
|
|
other end of the link. This occurs if either the Fabric or the
|
|
destination port is temporarily busy. FBSY can only occur on
|
|
SOFc1 frames (the frames that establish a connection). Note,
|
|
this is a Fibre Channel only stat."
|
|
::= { connUnitPortStatEntry 16 }
|
|
|
|
connUnitPortStatCountClass1PBSYFrames OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Count of times that PBSY was returned to this port as a result
|
|
of a Class 1 Frame that could not be delivered to the other end
|
|
of the link. This occurs if the destination N_Port is temporarily
|
|
busy. PBSY can only occur on SOFc1 frames (the frames that
|
|
establish a connection). Note, this is a Fibre Channel only
|
|
stat."
|
|
::= { connUnitPortStatEntry 17 }
|
|
|
|
connUnitPortStatCountClass1FRJTFrames OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Count of times that FRJT was returned to this port as a result
|
|
of a Class 1 Frame that was rejected by the fabric. Note, this
|
|
is a Fibre Channel only stat."
|
|
::= { connUnitPortStatEntry 18 }
|
|
|
|
connUnitPortStatCountClass1PRJTFrames OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Count of times that FRJT was returned to this port as a result
|
|
of a Class 1 Frame that was rejected at the destination N_Port.
|
|
Note, this is a Fibre Channel only stat."
|
|
::= { connUnitPortStatEntry 19 }
|
|
|
|
connUnitPortStatCountClass2RxFrames OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Count of Class 2 Frames received at this port. Note, this
|
|
is a Fibre Channel only stat."
|
|
::= { connUnitPortStatEntry 20 }
|
|
|
|
connUnitPortStatCountClass2TxFrames OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Count of Class 2 Frames transmitted out this port. Note,
|
|
this is a Fibre Channel only stat."
|
|
::= { connUnitPortStatEntry 21 }
|
|
|
|
connUnitPortStatCountClass2FBSYFrames OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Count of times that FBSY was returned to this port as a
|
|
result of a Class 2 Frame that could not be delivered to the
|
|
other end of the link. This occurs if either the Fabric or the
|
|
destination port is temporarily busy. FBSY can only occur on
|
|
SOFc1 frames (the frames that establish a connection). Note,
|
|
this is a Fibre Channel only stat."
|
|
::= { connUnitPortStatEntry 22 }
|
|
|
|
connUnitPortStatCountClass2PBSYFrames OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Count of times that PBSY was returned to this port as a result
|
|
of a Class 2 Frame that could not be delivered to the other end
|
|
of the link. This occurs if the destination N_Port is temporarily
|
|
busy. PBSY can only occur on SOFc1 frames (the frames that
|
|
establish a connection). Note, this is a Fibre Channel only
|
|
stat."
|
|
::= { connUnitPortStatEntry 23 }
|
|
|
|
connUnitPortStatCountClass2FRJTFrames OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Count of times that FRJT was returned to this port as a result
|
|
of a Class 2 Frame that was rejected by the fabric. Note, this
|
|
is a Fibre Channel only stat."
|
|
::= { connUnitPortStatEntry 24 }
|
|
|
|
connUnitPortStatCountClass2PRJTFrames OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Count of times that FRJT was returned to this port as a result
|
|
of a Class 2 Frame that was rejected at the destination N_Port.
|
|
Note, this is a Fibre Channel only stat."
|
|
::= { connUnitPortStatEntry 25 }
|
|
|
|
connUnitPortStatCountClass3RxFrames OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Count of Class 3 Frames received at this port. Note, this
|
|
is a Fibre Channel only stat."
|
|
::= { connUnitPortStatEntry 26 }
|
|
|
|
connUnitPortStatCountClass3TxFrames OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Count of Class 3 Frames transmitted out this port. Note,
|
|
this is a Fibre Channel only stat."
|
|
::= { connUnitPortStatEntry 27 }
|
|
|
|
connUnitPortStatCountClass3Discards OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Count of Class 3 Frames that were discarded upon reception
|
|
at this port. There is no FBSY or FRJT generated for Class 3
|
|
Frames. They are simply discarded if they cannot be delivered.
|
|
Note, this is a Fibre Channel only stat."
|
|
::= { connUnitPortStatEntry 28 }
|
|
|
|
connUnitPortStatCountRxMulticastObjects OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Count of Multicast Frames or Packets received at this port."
|
|
::= { connUnitPortStatEntry 29 }
|
|
|
|
connUnitPortStatCountTxMulticastObjects OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Count of Multicast Frames or Packets transmitted out this port."
|
|
::= { connUnitPortStatEntry 30 }
|
|
|
|
connUnitPortStatCountRxBroadcastObjects OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Count of Broadcast Frames or Packets received at this port."
|
|
::= { connUnitPortStatEntry 31 }
|
|
|
|
connUnitPortStatCountTxBroadcastObjects OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Count of Broadcast Frames or Packets transmitted out this port.
|
|
On a Fibre Channel loop, count only OPNr frames generated."
|
|
::= { connUnitPortStatEntry 32 }
|
|
|
|
connUnitPortStatCountRxLinkResets OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Count of Link resets. This is the number of LRs received. Note, this
|
|
is a Fibre Channel only stat."
|
|
::= { connUnitPortStatEntry 33 }
|
|
|
|
connUnitPortStatCountTxLinkResets OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Count of Link resets. This is the number LRs transmitted. Note, this
|
|
is a Fibre Channel only stat."
|
|
::= { connUnitPortStatEntry 34 }
|
|
|
|
connUnitPortStatCountNumberLinkResets OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Count of Link resets and LIPs detected at this port.
|
|
The number times the reset link protocol is initiated.
|
|
These are the count of the logical resets, a count of the
|
|
number of primatives. Note, this is a Fibre Channel only
|
|
stat."
|
|
::= { connUnitPortStatEntry 35 }
|
|
|
|
connUnitPortStatCountRxOfflineSequences OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Count of Offline Primitive OLS received at this port.
|
|
Note, this is a Fibre Channel only stat."
|
|
::= { connUnitPortStatEntry 36 }
|
|
|
|
connUnitPortStatCountTxOfflineSequences OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Count of Offline Primitive OLS transmitted by this port.
|
|
Note, this is a Fibre Channel only stat."
|
|
::= { connUnitPortStatEntry 37 }
|
|
|
|
connUnitPortStatCountNumberOfflineSequences OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Count of Offline Primitive sequence received at this port.
|
|
Note, this is a Fibre Channel only stat."
|
|
::= { connUnitPortStatEntry 38 }
|
|
|
|
connUnitPortStatCountLinkFailures OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Count of link failures. This count is part of the Link Error
|
|
Status Block (LESB). (FC-PH 29.8). Note, this is a Fibre
|
|
Channel only stat."
|
|
::= { connUnitPortStatEntry 39 }
|
|
|
|
connUnitPortStatCountInvalidCRC OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Count of frames received with invalid CRC. This count is
|
|
part of the Link Error Status Block (LESB). (FC-PH 29.8). Loop
|
|
ports should not count CRC errors passing through when
|
|
monitoring. Note, this is a Fibre Channel only stat."
|
|
::= { connUnitPortStatEntry 40 }
|
|
|
|
connUnitPortStatCountInvalidTxWords OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Count of invalid transmission words received at this
|
|
port. This count is part of the Link Error Status Block (LESB).
|
|
(FC-PH 29.8). Note, this is a Fibre Channel only stat."
|
|
::= { connUnitPortStatEntry 41 }
|
|
|
|
connUnitPortStatCountPrimitiveSequenceProtocolErrors OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Count of primitive sequence protocol errors detected at
|
|
this port. This count is part of the Link Error Status
|
|
Block (LESB). (FC-PH 29.8). Note, this is a Fibre Channel
|
|
only stat."
|
|
::= { connUnitPortStatEntry 42 }
|
|
|
|
connUnitPortStatCountLossofSignal OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Count of instances of signal loss detected at port.
|
|
This count is part of the Link Error Status Block (LESB).
|
|
(FC-PH 29.8). Note, this is a Fibre Channel only stat."
|
|
::= { connUnitPortStatEntry 43 }
|
|
|
|
connUnitPortStatCountLossofSynchronization OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Count of instances of synchronization loss detected at port.
|
|
This count is part of the Link Error Status Block (LESB).
|
|
(FC-PH 29.8). Note, this is a Fibre Channel only stat."
|
|
::= { connUnitPortStatEntry 44 }
|
|
|
|
connUnitPortStatCountInvalidOrderedSets OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Count of invalid ordered sets received at port. This count
|
|
is part of the Link Error Status Block (LESB). (FC-PH 29.8).
|
|
Note, this is a Fibre Channel only stat."
|
|
::= { connUnitPortStatEntry 45 }
|
|
|
|
connUnitPortStatCountFramesTooLong OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Count of frames received at this port where the
|
|
frame length was greater than what was agreed to in
|
|
FLOGI/PLOGI. This could be caused by losing the end of
|
|
frame delimiter. Note, this is a Fibre Channel only stat."
|
|
::= { connUnitPortStatEntry 46 }
|
|
|
|
connUnitPortStatCountFramesTruncated OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Count of frames received at this port where the
|
|
frame length was less than the minimum indicated by the
|
|
frame header - normally 24 bytes, but it could be more if the
|
|
DFCTL field indicates an optional header should have been
|
|
present. Note, this is a Fibre Channel only stat."
|
|
::= { connUnitPortStatEntry 47 }
|
|
|
|
connUnitPortStatCountAddressErrors OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Count of frames received with unknown addressing.
|
|
e.x. unknown SID or DID. the SID or DID is not known to the
|
|
routing algorithm. Note. this is a Fibre Channel only stat."
|
|
::= { connUnitPortStatEntry 48 }
|
|
|
|
connUnitPortStatCountDelimiterErrors OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Count of invalid frame delimiters received at this
|
|
port. An example is a frame with a class 2 start and and a
|
|
class 3 at the end. Note, this is a Fibre Channel only stat."
|
|
::= { connUnitPortStatEntry 49 }
|
|
|
|
connUnitPortStatCountEncodingDisparityErrors OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Count of disparity errors received at this port. Note,
|
|
this is a Fibre Channel only stat."
|
|
::= { connUnitPortStatEntry 50 }
|
|
|
|
|
|
--------------------------------------------------------------------
|
|
-- the Fibre Channel Simple Name Server table
|
|
--
|
|
-- The Fibre Channel Simple Name Server table contains an entry for each device
|
|
-- presently known to this connUnit. There will not be any version on this since
|
|
-- FC-GS3 does not define a version today.
|
|
--
|
|
-- This table is accessed either directly if the management
|
|
-- software has an index value or via GetNexts. The value of
|
|
-- the indexes are not required to be contiguous. Each entry
|
|
-- created in this table will be assigned an index. This
|
|
-- relationship is kept persistent until the entry is removed
|
|
-- from the table or the system is reset. The total number of
|
|
-- entries are defined by the size of the table
|
|
|
|
connUnitSnsMaxEntry OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum number of entries in the table."
|
|
::= { connUnitServiceScalars 1 }
|
|
|
|
connUnitSnsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ConnUnitSnsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains an entry for each object registered with
|
|
this port in the switch."
|
|
::= { connUnitServiceTables 1 }
|
|
|
|
connUnitSnsEntry OBJECT-TYPE
|
|
SYNTAX ConnUnitSnsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Simple Name Server table for the port represented by
|
|
connUnitSnsPortIndex ."
|
|
INDEX { connUnitSnsId, connUnitSnsPortIndex, connUnitSnsPortIdentifier }
|
|
::= { connUnitSnsTable 1 }
|
|
|
|
ConnUnitSnsEntry ::=
|
|
SEQUENCE {
|
|
connUnitSnsId
|
|
OCTET STRING,
|
|
connUnitSnsPortIndex
|
|
INTEGER,
|
|
connUnitSnsPortIdentifier
|
|
FcAddressId,
|
|
connUnitSnsPortName
|
|
FcNameId,
|
|
connUnitSnsNodeName
|
|
FcNameId,
|
|
connUnitSnsClassOfSvc
|
|
OCTET STRING,
|
|
connUnitSnsNodeIPAddress
|
|
OCTET STRING,
|
|
connUnitSnsProcAssoc
|
|
OCTET STRING,
|
|
connUnitSnsFC4Type
|
|
OCTET STRING,
|
|
connUnitSnsPortType
|
|
OCTET STRING,
|
|
connUnitSnsPortIPAddress
|
|
OCTET STRING,
|
|
connUnitSnsFabricPortName
|
|
FcNameId,
|
|
connUnitSnsHardAddress
|
|
FcAddressId,
|
|
connUnitSnsSymbolicPortName
|
|
DisplayString,
|
|
connUnitSnsSymbolicNodeName
|
|
DisplayString
|
|
}
|
|
|
|
connUnitSnsId OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (16))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The connUnitId of the connectivity unit
|
|
that contains this Name Server table."
|
|
::= { connUnitSnsEntry 1 }
|
|
|
|
connUnitSnsPortIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The physical port number of this SNS table entry. Each physical port
|
|
has an SNS table with 1-n entries indexed by connUnitSnsPortIdentifier (port
|
|
address)"
|
|
::= { connUnitSnsEntry 2 }
|
|
|
|
connUnitSnsPortIdentifier OBJECT-TYPE
|
|
SYNTAX FcAddressId
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Port Identifier for this entry in the SNS table."
|
|
::= { connUnitSnsEntry 3 }
|
|
|
|
connUnitSnsPortName OBJECT-TYPE
|
|
SYNTAX FcNameId
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Port Name for this entry in the SNS table."
|
|
::= { connUnitSnsEntry 4 }
|
|
|
|
connUnitSnsNodeName OBJECT-TYPE
|
|
SYNTAX FcNameId
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Node Name for this entry in the SNS table."
|
|
::= { connUnitSnsEntry 5 }
|
|
|
|
connUnitSnsClassOfSvc OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Classes of Service offered by this entry in the SNS table."
|
|
::= { connUnitSnsEntry 6 }
|
|
|
|
connUnitSnsNodeIPAddress OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(16))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IPv6 formatted address of the Node for this entry in the SNS table."
|
|
|
|
::= { connUnitSnsEntry 7 }
|
|
|
|
connUnitSnsProcAssoc OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Process Associator for this entry in the SNS table."
|
|
::= { connUnitSnsEntry 8 }
|
|
|
|
connUnitSnsFC4Type OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The FC-4 Types supported by this entry in the SNS table."
|
|
::= { connUnitSnsEntry 9 }
|
|
|
|
connUnitSnsPortType OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Port Type of this entry in the SNS table."
|
|
::= { connUnitSnsEntry 10 }
|
|
|
|
connUnitSnsPortIPAddress OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(16))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The IPv6 formatted address of this entry in the SNS table."
|
|
::= { connUnitSnsEntry 11 }
|
|
|
|
connUnitSnsFabricPortName OBJECT-TYPE
|
|
SYNTAX FcNameId
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Fabric Port name of this entry in the SNS table."
|
|
::= { connUnitSnsEntry 12 }
|
|
|
|
connUnitSnsHardAddress OBJECT-TYPE
|
|
SYNTAX FcAddressId
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Hard Address of this entry in the SNS table."
|
|
::= { connUnitSnsEntry 13 }
|
|
|
|
connUnitSnsSymbolicPortName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..79))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Symbolic Port Name of this entry in the SNS table."
|
|
::= { connUnitSnsEntry 14 }
|
|
|
|
connUnitSnsSymbolicNodeName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..79))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Symbolic Node Name of this entry in the SNS table."
|
|
::= { connUnitSnsEntry 15 }
|
|
|
|
|
|
-----------------------------------------------------------------------
|
|
-- SNMP trap registration group
|
|
|
|
trapMaxClients OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum number of SNMP trap recipients
|
|
supported by the connectivity unit."
|
|
::= { trapReg 1 }
|
|
|
|
trapClientCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current number of rows in the trap table."
|
|
::= { trapReg 2 }
|
|
|
|
trapRegTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TrapRegEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table containing a row for each IP address/port
|
|
number that traps will be sent to."
|
|
::= { trapReg 3 }
|
|
|
|
trapRegEntry OBJECT-TYPE
|
|
SYNTAX TrapRegEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Ip/Port pair for a specific client."
|
|
INDEX { trapRegIpAddress,
|
|
trapRegPort }
|
|
::= { trapRegTable 1 }
|
|
|
|
TrapRegEntry ::=
|
|
SEQUENCE {
|
|
trapRegIpAddress
|
|
IpAddress,
|
|
trapRegPort
|
|
INTEGER,
|
|
trapRegFilter
|
|
FcEventSeverity,
|
|
trapRegRowState
|
|
INTEGER
|
|
}
|
|
|
|
trapRegIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Ip address of a client registered for
|
|
traps."
|
|
::= { trapRegEntry 1 }
|
|
|
|
trapRegPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The UDP port to send traps to for this host.
|
|
Normally this would be the standard trap port
|
|
(162). This object is an index and must be
|
|
specified to create a row in this table."
|
|
::= { trapRegEntry 2 }
|
|
|
|
trapRegFilter OBJECT-TYPE
|
|
SYNTAX FcEventSeverity
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value defines the trap severity
|
|
filter for this trap host. The connUnit will send
|
|
traps to this host that have a severity level
|
|
less than or equal to this value.
|
|
The default value of this object is 'warning'."
|
|
::= { trapRegEntry 3}
|
|
|
|
trapRegRowState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
rowDestroy(1), -- Remove row from table.
|
|
rowInactive(2), -- Row exists, but TRAPs disabled
|
|
rowActive(3) -- Row exists and is enabled for
|
|
-- sending traps
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Specifies the state of the row.
|
|
rowDestroy
|
|
READ: Can never happen.
|
|
WRITE: Remove this row from the table.
|
|
rowInactive
|
|
READ: Indicates that this row does exist, but
|
|
that traps are not enabled to be sent to the
|
|
target.
|
|
WRITE: If the row does not exist, and the agent
|
|
allows writes to the trap table, then a new
|
|
row is created. The values of the optional
|
|
columns will be set to default values. Traps are
|
|
not enabled to be sent to the target. If the row
|
|
already existed, then traps are disabled from being
|
|
sent to the target.
|
|
rowActive
|
|
READ: Indicates that this row exists, and that traps
|
|
are enabled to be sent to the target.
|
|
WRITE: If the row does not exist, and the agent
|
|
allows writes to the trap table, then a new row is
|
|
created. The values of the optional columns will be
|
|
set to default values. Traps are enabled to be sent
|
|
to the target. If the row already exists, then traps
|
|
are enabled to be sent to the target.
|
|
|
|
A value of rowActive or rowInactive must be specified to
|
|
create a row in the table."
|
|
::= { trapRegEntry 4}
|
|
|
|
|
|
-- Related traps
|
|
|
|
connUnitStatusChange TRAP-TYPE
|
|
ENTERPRISE fcmgmt
|
|
VARIABLES { connUnitStatus, connUnitState }
|
|
DESCRIPTION
|
|
"The overall status of the connectivity unit has
|
|
changed.
|
|
Recommended severity level (for filtering): alert"
|
|
::= 1
|
|
|
|
-- connUnitAddedTrap , 2, no longer used
|
|
|
|
connUnitDeletedTrap TRAP-TYPE
|
|
ENTERPRISE fcmgmt
|
|
VARIABLES { connUnitId }
|
|
DESCRIPTION
|
|
"A connUnit has been deleted from this agent.
|
|
Recommended severity level (for filtering): warning"
|
|
::= 3
|
|
|
|
connUnitEventTrap TRAP-TYPE
|
|
ENTERPRISE fcmgmt
|
|
VARIABLES { connUnitEventId,
|
|
connUnitEventType,
|
|
connUnitEventObject,
|
|
connUnitEventDescr }
|
|
DESCRIPTION
|
|
"An event has been generated by the
|
|
connectivity unit.
|
|
Recommended severity level (for filtering): info"
|
|
::= 4
|
|
|
|
connUnitSensorStatusChange TRAP-TYPE
|
|
ENTERPRISE fcmgmt
|
|
VARIABLES { connUnitSensorStatus }
|
|
DESCRIPTION
|
|
"The overall status of the connectivity unit has
|
|
changed.
|
|
Recommended severity level (for filtering): alert"
|
|
::= 5
|
|
|
|
connUnitPortStatusChange TRAP-TYPE
|
|
ENTERPRISE fcmgmt
|
|
VARIABLES { connUnitPortStatus, connUnitPortState }
|
|
DESCRIPTION
|
|
"The overall status of the connectivity unit has
|
|
changed.
|
|
Recommended severity level (for filtering): alert"
|
|
::= 6
|
|
|
|
END
|
|
|
|
|
|
|