librenms/mibs/mib-jnx-if-extensions.txt
Adam Amstrong 10fed1baf0 add mibs!
git-svn-id: http://www.observium.org/svn/observer/trunk@413 61d68cd4-352d-0410-923a-c4978735b2b8
2009-04-28 12:43:50 +00:00

551 lines
17 KiB
Plaintext

--
-- Juniper Enterprise Specific MIB: Interface MIB Extension
--
-- Copyright (c) 1999-2003, 2007, Juniper Networks, Inc.
-- All rights reserved.
--
-- The contents of this document are subject to change without notice.
--
JUNIPER-IF-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Gauge32, Integer32, Counter64, Counter32
FROM SNMPv2-SMI
CounterBasedGauge64
FROM HCNUM-TC
ifEntry,ifIndex
FROM IF-MIB
TimeStamp
FROM SNMPv2-TC
jnxMibs
FROM JUNIPER-SMI;
ifJnx MODULE-IDENTITY
LAST-UPDATED "200307182153Z" -- Fri Jul 18 21:53:51 2003 UTC
ORGANIZATION "Juniper Networks, Inc."
CONTACT-INFO
" Juniper Technical Assistance Center
Juniper Networks, Inc.
1194 N. Mathilda Avenue
Sunnyvale, CA 94089
E-mail: support@juniper.net"
DESCRIPTION
"The MIB modules extends the ifTable as
defined in IF-MIB."
REVISION "200706050000Z" -- 05 June, 2007
DESCRIPTION
"New Time Domain Reflectometery Added"
REVISION "200210310000Z" -- 31 Oct, 2002
DESCRIPTION
"New error counters added to ifJnxTable"
REVISION "200106210000Z" -- 21 June, 2001
DESCRIPTION
"New objects ifHCIn1SecRate and
ifHCOut1SecRate added"
REVISION "200103150000Z" -- 15 March, 2001
DESCRIPTION
"Initial Version"
::= { jnxMibs 3 }
--
-- This table augments ifTable
--
ifJnxTable OBJECT-TYPE
SYNTAX SEQUENCE OF IfJnxEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of Juniper's extension to the interface entries.
The number of entries is given by the value of ifNumber.
This table contains additional objects for the interface
table."
::= { ifJnx 1 }
ifJnxEntry OBJECT-TYPE
SYNTAX IfJnxEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing additional management information
applicable to a particular interface."
AUGMENTS { ifEntry }
::= { ifJnxTable 1 }
IfJnxEntry ::=
SEQUENCE {
ifIn1SecRate Gauge32,
ifIn1SecOctets Gauge32,
ifIn1SecPkts Gauge32,
ifOut1SecRate Gauge32,
ifOut1SecOctets Gauge32,
ifOut1SecPkts Gauge32,
ifHCIn1SecRate CounterBasedGauge64,
ifHCOut1SecRate CounterBasedGauge64,
ifJnxInErrors Counter64,
ifJnxInFrameErrors Counter64,
ifJnxInQDrops Counter64,
ifJnxInRunts Counter64,
ifJnxInGiants Counter64,
ifJnxInDiscards Counter64,
ifJnxInHslCrcErrors Counter64,
ifJnxInHslFifoOverFlows Counter64,
ifJnxInL3Incompletes Counter64,
ifJnxInL2ChanErrors Counter64,
ifJnxInL2MismatchTimeouts Counter64,
ifJnxInInvalidVCs Counter64,
ifJnxInFifoErrors Counter32,
ifJnxBucketDrops Counter64,
ifJnxSramErrors Counter32,
ifJnxOutErrors Counter64,
ifJnxCollisions Counter64,
ifJnxCarrierTrans Counter64,
ifJnxOutQDrops Counter64,
ifJnxOutAgedErrors Counter64,
ifJnxOutFifoErrors Counter32,
ifJnxOutHslFifoUnderFlows Counter64,
ifJnxOutHslCrcErrors Counter32
}
ifIn1SecRate OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of bits per second (bps), delivered by
this (sub-)layer to its next higher (sub-)layer."
::= { ifJnxEntry 1 }
ifIn1SecOctets OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of octets per second (Bps, Bytes per
second), delivered by this (sub-)layer to its next
higher (sub-)layer."
::= { ifJnxEntry 2 }
ifIn1SecPkts OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets per second (pps), delivered
by this (sub-)layer to its next higher (sub-)layer."
::= { ifJnxEntry 3 }
ifOut1SecRate OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of bits per second (bps), delivered by
this (sub-)layer to its next lower (sub-)layer."
::= { ifJnxEntry 4 }
ifOut1SecOctets OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of octets per second (Bps, Bytes per
second), delivered by this (sub-)layer to its next
lower (sub-)layer."
::= { ifJnxEntry 5 }
ifOut1SecPkts OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets per second (pps), delivered
by this (sub-)layer to its next lower (sub-)layer."
::= { ifJnxEntry 6 }
ifHCIn1SecRate OBJECT-TYPE
SYNTAX CounterBasedGauge64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of bits per second (bps), delivered by
this (sub-)layer to its next higher (sub-)layer.
This object is a 64 bit version of ifIn1SecRate."
::= { ifJnxEntry 7 }
ifHCOut1SecRate OBJECT-TYPE
SYNTAX CounterBasedGauge64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of bits per second (bps), delivered by
this (sub-)layer to its next lower (sub-)layer.
This object is a 64 bit version of ifOut1SecRate."
::= { ifJnxEntry 8 }
ifJnxInErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Errors: The sum of the incoming frame aborts and FCS errors."
::= { ifJnxEntry 9 }
ifJnxInFrameErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Framing Errors: The number of input packets which were
misaligned."
::= { ifJnxEntry 10 }
ifJnxInQDrops OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Drops: The number of packets dropped by the input queue of
the I/O Manager ASIC."
::= { ifJnxEntry 11 }
ifJnxInRunts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Runts: Frames received that are smaller than the runt
threshold."
::= { ifJnxEntry 12 }
ifJnxInGiants OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Giants: Frames received that are larger than the giant
threshold."
::= { ifJnxEntry 13 }
ifJnxInDiscards OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Policed Discards: Frames that the incoming packet match code
discarded because they were not recognized or of interest."
::= { ifJnxEntry 14 }
ifJnxInHslCrcErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HS Link CRC Errors: The number of CRC errors on the
high-speed links between the ASICs responsible for handling
the router interfaces while receiving packets."
::= { ifJnxEntry 15 }
ifJnxInHslFifoOverFlows OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HS link FIFO overflows: The number of FIFO overflows on the
high-speed links between the ASICs responsible for handling
the router interfaces."
::= { ifJnxEntry 16 }
ifJnxInL3Incompletes OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"L3 incompletes: The number of incoming packets that fail
Layer 3 sanity checks of the header."
::= { ifJnxEntry 17 }
ifJnxInL2ChanErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"L2 channel errors: the number of incoming packets for which
the sofware could not find a valid logical interface."
::= { ifJnxEntry 18 }
ifJnxInL2MismatchTimeouts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"L2 mismatch timeouts: The count of malformed or short packets
that cause the incoming packet handler to discard the frame
as unreadable."
::= { ifJnxEntry 19 }
ifJnxInInvalidVCs OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Invalid VCs: Number of cells that arrived for a nonexistent
virtual circuit."
::= { ifJnxEntry 20 }
ifJnxInFifoErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"FIFO errors: The number of FIFO errors in the receive
direction as reported by the ASIC on the PIC."
::= { ifJnxEntry 21 }
ifJnxBucketDrops OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bucket drops: Drops due to traffic load exceeding the
interface transmit/receive leaky bucket configuration."
::= { ifJnxEntry 22 }
ifJnxSramErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SRAM errors: This counter increments when a hardware error
has occurred in the SRAM on the PIC."
::= { ifJnxEntry 23 }
ifJnxOutErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Errors: The sum of the outgoing frame aborts and FCS errors."
::= { ifJnxEntry 24 }
ifJnxCollisions OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Collisions: The number of output collisions detected on this
interface."
::= { ifJnxEntry 25 }
ifJnxCarrierTrans OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Carrier transitions: The number of times the interface saw
the carrier signal transition."
::= { ifJnxEntry 26 }
ifJnxOutQDrops OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Drops: The number of packets dropped by the output queue of
the I/O Manager ASIC."
::= { ifJnxEntry 27 }
ifJnxOutAgedErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Aged packets: The number of packets that remained in shared
packet SDRAM for so long that the system automatically purged
them."
::= { ifJnxEntry 28 }
ifJnxOutFifoErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"FIFO errors: The number of FIFO errors in the transmit
direction as reported by the ASIC on the PIC."
::= { ifJnxEntry 29 }
ifJnxOutHslFifoUnderFlows OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HS link FIFO underflows: The number of FIFO underflows on the
high-speed links between the ASICs responsible for handling
the router interfaces."
::= { ifJnxEntry 30 }
ifJnxOutHslCrcErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"HS Link CRC Errors: The number of CRC errors on the
high-speed links between the ASICs responsible for handling
the router interfaces while transmitting packets."
::= { ifJnxEntry 31 }
--
-- This table augments ifTable to map to Chassis MIB tables
--
ifChassisTable OBJECT-TYPE
SYNTAX SEQUENCE OF IfChassisEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of Juniper's extension to the interface entries.
The number of entries is given by the value of ifNumber.
This table contains additional objects for the interface
table to facilitate the identification of interfaces and
its mapping into the Chassis MIB tables."
::= { ifJnx 2 }
ifChassisEntry OBJECT-TYPE
SYNTAX IfChassisEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing additional management information
applicable to a particular interface."
AUGMENTS { ifEntry }
::= { ifChassisTable 1 }
IfChassisEntry ::=
SEQUENCE {
ifChassisFpc Integer32,
ifChassisPic Integer32,
ifChassisPort Integer32,
ifChassisChannel Integer32,
ifChassisLogicalUnit Integer32,
ifChassisPicIndex OCTET STRING
}
ifChassisFpc OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of the FPC card on which the interface
is located in the chassis. It is the chassis slot
in which the FPC card is installed for the specified
interface.
Although the number is labeled from 0 and up in the
chassis, the return value for this object always starts
from 1 according to Network Management convention.
Therefore, a value of zero means there is no real or
physical FPC associated with the specified interface."
::= { ifChassisEntry 1 }
ifChassisPic OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of the PIC card on which the interface
is located in the chassis. It is the PIC location
on the FPC card for the specified interface.
Although the number is labeled from 0 and up in the
chassis, the return value for this object always starts
from 1 according to Network Management convention.
Therefore, a value of zero means there is no real or
physical PIC associated with the specified interface."
::= { ifChassisEntry 2 }
ifChassisPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of the port on the PIC card on which the
interface is located in the chassis. It is the port
number on the PIC card for the specified interface.
Although the number is labeled from 0 and up in the
chassis, the return value for this object always starts
from 1 according to Network Management convention.
Therefore, a value of zero means there is no real or
physical port associated with the specified interface."
::= { ifChassisEntry 3 }
ifChassisChannel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The channel identifier for the specified interface
if and only if it is part of a channelized interface.
Although the channel is numbered from 0 and up in the
interface naming, the return value for this object
always starts from 1 according to Network Management
convention. For the interface which could not be
channelized, this object returns zero."
::= { ifChassisEntry 4 }
ifChassisLogicalUnit OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The logical unit number of the specified interface.
It is the logical part of the interface that is
configured on the physical or channel part if any.
Although the logical unit number is numbered from 0 and
up in the interface naming, the return value for this
object always starts from 1 according to Network
Management convention. For the interface which is
really a physical device, this value returns zero."
::= { ifChassisEntry 5 }
ifChassisPicIndex OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index or indices for the Chassis MIB tables.
This is the instance index which keys into the
jnxContentsTable in Chassis MIB.
For example, it could return an octet string of
'8.1.2.0' - meaning a PIC ('8', first digit)
at FPC slot 0 ('1-1', second digit minus one if nonzero)
PIC number 1 ('2-1', third digit minus one if nonzero)
port number whatever (fourth digit currently unused)
- which in turn could be plugged in by NMS directly
after any MIB objects in the jnxContentsTable, say
'jnxContentsDescr.8.1.2.0', so NMS could get that
PIC object for the specified interface.
This object is valid only for those interfaces having
real and physical PIC cards. Otherwise, it returns
an octet string of four zeros '0.0.0.0.'"
::= { ifChassisEntry 6 }
END