librenms/mibs/siemens/ULAF2-MIB
2024-04-30 14:38:01 +02:00

1056 lines
29 KiB
Plaintext

ULAF2-MIB DEFINITIONS ::= BEGIN
--------------------------------------------------------------------------------
-- The lineintegrator MIB
-- ______________
--
-- 1. Introduction
-- This document defines the enterprise specific MIB for the LineIntegrater,
-- which provides the management of the ULAF-2 transmission family.
-- The MIB is divided into three basic MIBs
-- proxyAgent MIB
-- device MIB
-- links MIB
--
-- 2. The proxyAgent MIB
-- _____________________
--
-- The proxyAgent MIB consists of a table with information about the
-- supervised serial ports and the connected devices. Either an OMI
-- equipment or a NAG-2D.x can be connected.
--
--
-- 3. The device MIB
-- _________________
--
-- The device MIB is a table, where each entry refers to a line card slot.
-- It contains the name of the inserted cards and a alarm attribute, which
-- is used to send SNMP traps to the manager, if a link goes down.
--
-- 5. The links MIB
-- _____________________
--
-- The links MIB consists of several tables, which contain detailed
-- management information about the line cards.
-- The links MIB is divided into three parts
-- link
-- near
-- far
-- The near part contains only configuration information about the line
-- card.
-- The link part is separated into configuration, performance ,fault
-- management and alarm management. In addition the performance part contains
-- a table about attenuation and error estimation of HDSL links (hdslTable).
--
-- 16.12.96 Urs Aebersold, Siemens Switzerland Ltd.
--------------------------------------------------------------------------------
IMPORTS
enterprises, NetworkAddress, IpAddress, Counter, Gauge,
TimeTicks
FROM RFC1155-SMI
DisplayString
FROM RFC1213-MIB
OBJECT-TYPE
FROM RFC-1212;
siemensCH OBJECT IDENTIFIER ::= { enterprises 1887 }
lineintegrator OBJECT IDENTIFIER ::= { siemensCH 1 }
ulaf2 OBJECT IDENTIFIER ::= { lineintegrator 1 }
proxyAgent OBJECT IDENTIFIER ::= { ulaf2 1 }
proxyAgtVers2 OBJECT IDENTIFIER ::= { proxyAgent 2 }
device OBJECT IDENTIFIER ::= { ulaf2 3 }
links OBJECT IDENTIFIER ::= { ulaf2 4 }
linksVers2 OBJECT IDENTIFIER ::= { links 2 }
--------------------------------------------------------------------------------
agtSystem OBJECT IDENTIFIER ::= { proxyAgtVers2 1 }
--------------------------------------------------------------------------------
agtSWVersion OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains software version of Proxy Subagent."
::= { agtSystem 1 }
agtDateLastPortChange OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains time when the connected device or the type of link of a device
equipment has changed.(Link Up and Down traps)."
::= { agtSystem 2 }
agtProxyFeatureFlag OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(33))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains a map of features supported by the local device.
Byte 0-31 contain the bit-coded feature flags 0..255
Byte 32 contains information about the validity of the
previous 32 bytes.
1 Ok The information in bytes 0..31 is valid
254 unknown values
255 unsupported variable for addressed device"
::= { agtSystem 3 }
agtProxyAciSupported OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Identifies this device as Ulaf+ OMI SNMP towards
Access Integrator. Always returns 'FullAciSupport'"
::= { agtSystem 4 }
--------------------------------------------------------------------------------
agtSerialPort OBJECT IDENTIFIER ::= { proxyAgtVers2 2 }
--------------------------------------------------------------------------------
agtPortNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object contains the number of available serial ports"
::= { agtSerialPort 1 }
agtPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgtPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { agtSerialPort 2 }
agtPortEntry OBJECT-TYPE
SYNTAX AgtPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
INDEX { agtPortIndex }
::= { agtPortTable 1 }
AgtPortEntry ::=
SEQUENCE
{
agtPortIndex INTEGER,
agtPortName DisplayString,
agtPortConnected INTEGER,
agtConnectedDevice DisplayString,
agtPortType INTEGER,
agtPortTypeNumber INTEGER,
agtPortServerName DisplayString,
agtPortState INTEGER,
agtPortDeviceFamily INTEGER,
agtPortTryingDevice INTEGER
}
agtPortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object corresponds to the port number. Ports are
enumarated beginning with one."
::= { agtPortEntry 1 }
agtPortName OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains name of device file"
::= { agtPortEntry 2 }
agtPortConnected OBJECT-TYPE
SYNTAX INTEGER
{
no(1),
yes(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object tells the agent, if the appropriate serial port
is used or not."
::= { agtPortEntry 3 }
agtConnectedDevice OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object contains the name of the connected device (e.g OMIBG)."
::= { agtPortEntry 4 }
agtPortType OBJECT-TYPE
SYNTAX INTEGER
{
local(1),
portType(2),
portServer(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object describes if the port is a local RS232 serial port,
a locally installed serial port card or the port is a remote
port of a port server"
::= { agtPortEntry 5 }
agtPortTypeNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object contains the number of the serial port of the
appropriate port type defined in agtPortType."
::= { agtPortEntry 6 }
agtPortServerName OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object contains a name to identify the port server"
::= { agtPortEntry 7 }
agtPortState OBJECT-TYPE
------------------------------------
-- new in V3.0
------------------------------------
SYNTAX INTEGER
{
unopenedSerial(1),
openedSerial(2),
connectingRemote(3),
openedRemote(4),
failedRemote(5),
disabled(6),
invalid(7),
unknown(254)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable shows in which reconnection state a port is.
The first two states refer to local serial ports or to
PortServer ports using the Digi RealPort drivers, the last
three states refer to PortServer ports using the
proprietory method of LineIntegrator.
1 UnopenedSerial Serial port, not opened
2 OpenedSerial Serial port, opened
3 ConnectingRemote Remote port, waiting for connection
4 OpenedRemote Remote port, opened
5 FailedRemote Remote port, connection failed
6 Disabled Port is disabled
7 Invalid Port entry is invalid (configuration file problem)
254 Unknown Unknown value"
::= { agtPortEntry 8 }
agtPortDeviceFamily OBJECT-TYPE
------------------------------------
-- new in V3.0
------------------------------------
SYNTAX INTEGER
{
ulaf2(1),
ulafPlus(2),
ulaf2AndPlus(3),
unknown(254)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable shows which device family will be tried during
the auto-discovery phase.
1 Ulaf2 Ulaf-2 Devices (OMI, NAG) will be discovered
2 UlafPlus Ulaf+ Devices (OMI, XTU) will be discovered
3 Ulaf2AndPlus Ulaf-2 and Ulaf+ devices will be discovered
254 Unknown Unknown value"
::= { agtPortEntry 9 }
agtPortTryingDevice OBJECT-TYPE
------------------------------------
-- new in V3.0
------------------------------------
SYNTAX INTEGER
{
disabled(1),
invalid(2),
none(3),
omi(4),
nag(5),
omiPlus(6),
desktopPlus(7),
unknown(254)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable shows which device is currently being tried on the port.
If no answer is received during 5 seconds, the next device will be tried
1 Disabled The port has been disabled, no device will be tried
2 Invalid The port is invalid, no device will be tried
3 None No device is being tried at the moment
4 Omi Trying Ulaf-2 OMI
5 Nag Trying Ulaf-2 NAG Desktop
6 OmiPlus Trying Ulaf+ OMI
7 DesktopPlus Trying Ulaf+ Desktop
254 Unknown Unknown value"
::= { agtPortEntry 10 }
--------------------------------------------------------------------------------
agtAlarmCountGroup OBJECT IDENTIFIER ::= { proxyAgtVers2 3 }
--------------------------------------------------------------------------------
agtAlarmCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object counts the number of Alarm traps
sent by this proxy since the last time the
variable has been read."
::= { agtAlarmCountGroup 1 }
--------------------------------------------------------------------------------
--------------------------------------------------------------------------------
agtPortServerReset OBJECT-TYPE
SYNTAX INTEGER
{
reset(1),
unknown(254)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This variable cannot be read (it returns unknown if read)
If reset(1) is written to it, the proxy tries to reset all
DigiInternational PortServers. It does not reset any other
manufacturer's port servers.
This step can be necessary, if a router between the proxy
and a PortServer has crashed and the PortServer keeps open
a stale connection to which the proxy can no longer connect.
Do not use this feature manually but use the option in the
LineIntegrator Menu in HP OpenView NNM."
::= { proxyAgtVers2 4 }
--------------------------------------------------------------------------------
-------------------------------------------------------------------------------
--
-- { COMMENTED OUT THIS SECTION, bee, 30-11-2000
--
-- This section has been deactivated after having been tested
-- the proxy supports these variables in principle but as the
-- OMI SNMP does not yet support them, this section of the
-- mib has been commented out. furthermore the corresponding
-- support in the proxy is beeing suppressed in the undefs.h
-- file.
--
-- to reactivate the section, you need to
-- - remove the undef lines from ~/work/proxy/src/undefs.h
-- - remove the minus (-) signs at the beginning of this
-- block (the curly bracket on the first comment line
-- is conveniently matched with a comment block at the
-- end, so Ctrl-G in Joe should jump between them)
--
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
-- agtOmiSnmpIpData OBJECT IDENTIFIER ::= { proxyAgtVers2 5 }
--
-------------------------------------------------------------------------------
--agtOmiSnmpIpDataMacAddress OBJECT-TYPE
-- SYNTAX OCTET STRING (SIZE(6))
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "Returns the 6 bytes of the OMI SNMP's or Proxy's
-- MAC Address"
-- ::= { agtOmiSnmpIpData 1 }
--
--agtOmiSnmpIpDataIpAddress OBJECT-TYPE
-- SYNTAX IpAddress
-- ACCESS read-write
-- STATUS mandatory
-- DESCRIPTION
-- "Returns the 4 bytes of the OMI SNMP's or Proxy's
-- IP Address"
-- ::= { agtOmiSnmpIpData 2 }
--
--agtOmiSnmpIpDataSubnetMask OBJECT-TYPE
-- SYNTAX IpAddress
-- ACCESS read-write
-- STATUS mandatory
-- DESCRIPTION
-- "Returns the 4 bytes of the OMI SNMP's or Proxy's
-- Subnet Mask"
-- ::= { agtOmiSnmpIpData 3 }
--
--agtOmiSnmpIpDataDefaultRouter OBJECT-TYPE
-- SYNTAX IpAddress
-- ACCESS read-write
-- STATUS mandatory
-- DESCRIPTION
-- "Returns the 4 bytes of the OMI SNMP's or Proxy's
-- Default Router IP Address"
-- ::= { agtOmiSnmpIpData 4 }
--
--agtOmiSnmpIpDataTrapDestNumber OBJECT-TYPE
-- SYNTAX INTEGER
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "Contains the number of entries in the
-- Trap Destination Table"
-- ::= { agtOmiSnmpIpData 5 }
--
--agtOmiSnmpIpDataTrapDestTable OBJECT-TYPE
-- SYNTAX SEQUENCE OF AgtOmiSnmpIpDataTrapDestEntry
-- ACCESS not-accessible
-- STATUS mandatory
-- DESCRIPTION
-- "Contains the IP Settings of the OMI SNMP"
-- ::= { agtOmiSnmpIpData 6 }
--
--agtOmiSnmpIpDataTrapDestEntry OBJECT-TYPE
-- SYNTAX AgtOmiSnmpIpDataTrapDestEntry
-- ACCESS not-accessible
-- STATUS mandatory
-- DESCRIPTION
-- "Contains the IP Settings of the OMI SNMP"
-- INDEX { agtOmiSnmpIpDataTrapDestIndex }
-- ::= { agtOmiSnmpIpDataTrapDestTable 1 }
--
--AgtOmiSnmpIpDataTrapDestEntry ::=
-- SEQUENCE
-- {
-- agtOmiSnmpIpDataTrapDestIndex INTEGER,
-- agtOmiSnmpIpDataTrapDestAddress OCTET STRING
-- }
--
--agtOmiSnmpIpDataTrapDestIndex OBJECT-TYPE
-- SYNTAX INTEGER
-- ACCESS read-only
-- STATUS mandatory
-- DESCRIPTION
-- "Index to the Trap Destinations"
-- ::= { agtOmiSnmpIpDataTrapDestEntry 1 }
--
--agtOmiSnmpIpDataTrapDestAddress OBJECT-TYPE
-- SYNTAX IpAddress
-- ACCESS read-write
-- STATUS mandatory
-- DESCRIPTION
-- "Returns the 4 bytes of the OMI SNMP's or Proxy's
-- Trap Destinations"
-- ::= { agtOmiSnmpIpDataTrapDestEntry 2 }
--
------------------------------------------------------------------------------
--
-- END OF COMMENTED OUT SECTION, bee, 30-11-2000 }
--
------------------------------------------------------------------------------
--------------------------------------------------------------------------------
deviceVers2 OBJECT IDENTIFIER ::= { device 2 }
--------------------------------------------------------------------------------
--------------------------------------------------------------------------------
deviceSystem OBJECT IDENTIFIER ::= { deviceVers2 1 }
--------------------------------------------------------------------------------
deviceSystemTable OBJECT-TYPE
SYNTAX SEQUENCE OF DeviceSystemEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { deviceSystem 1 }
deviceSystemEntry OBJECT-TYPE
SYNTAX DeviceSystemEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
INDEX { deviceSystemPortIndex }
::= { deviceSystemTable 1 }
DeviceSystemEntry ::=
SEQUENCE
{
deviceSystemPortIndex INTEGER,
deviceLinkNumber INTEGER,
deviceSWVersion DisplayString,
deviceExtAlarm INTEGER,
deviceDateLastLinkChange INTEGER,
deviceOmiFeatureFlag OCTET STRING
}
deviceSystemPortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object addresses the port of the proxy agent."
::= { deviceSystemEntry 1 }
deviceLinkNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object contains the maximum number of supported line cards "
::= { deviceSystemEntry 2 }
deviceSWVersion OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains software version of device."
::= { deviceSystemEntry 3 }
deviceExtAlarm OBJECT-TYPE
SYNTAX INTEGER
{
noAlarm(1),
urgent(2),
notUrgent(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object contains the external alarm of the OMI equipment."
::= { deviceSystemEntry 4 }
deviceDateLastLinkChange OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object contains the absolute date and time when the type
of link has changed its configuration.
(e.g. removing a line card).
(Link Up and Link Down Traps)"
::= { deviceSystemEntry 5 }
deviceOmiFeatureFlag OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(33))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains a map of features supported by the local device.
Byte 0-31 contain the bit-coded feature flags 0..255
Byte 32 contains information about the validity of the
previous 32 bytes.
1 Ok The information in bytes 0..31 is valid
254 unknown values
255 unsupported variable for addressed device"
::= { deviceSystemEntry 6 }
--------------------------------------------------------------------------------
deviceLinks OBJECT IDENTIFIER ::= { deviceVers2 2 }
--------------------------------------------------------------------------------
deviceLinkTable OBJECT-TYPE
SYNTAX SEQUENCE OF DeviceLinkEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { deviceLinks 1 }
deviceLinkEntry OBJECT-TYPE
SYNTAX DeviceLinkEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
INDEX { devicePortIndex, deviceLinkIndex }
::= { deviceLinkTable 1 }
DeviceLinkEntry ::=
SEQUENCE
{
devicePortIndex
INTEGER,
deviceLinkIndex
INTEGER,
deviceLinkName
DisplayString,
deviceLinkAlarm
INTEGER,
-------------------------------
-- added in V3.0
-------------------------------
deviceLinkLocalLtNt INTEGER,
deviceLinkLocalId DisplayString,
deviceLinkFarId DisplayString,
deviceLinkNumReg1 INTEGER,
deviceLinkNumReg2 INTEGER,
deviceLinkLocalModules INTEGER,
deviceLinkFarModules INTEGER,
deviceLinkLocalHwFabData DisplayString,
deviceLinkFarHwFabData DisplayString,
deviceLinkLocalG703FabData DisplayString,
deviceLinkLocalDataFabData DisplayString,
-------------------------------
-- added in V3.1
-------------------------------
deviceLinkLocalFeatureFlag OCTET STRING,
deviceLinkFarFeatureFlag OCTET STRING,
deviceLinkFarFeatureFlagState INTEGER,
-------------------------------
-- added in V3.4
-------------------------------
deviceLinkSruFeatureFlag OCTET STRING,
deviceLinkNumReg3 INTEGER,
deviceLinkNumReg4 INTEGER
}
devicePortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object addresses the port of the proxy agent."
::= { deviceLinkEntry 1 }
deviceLinkIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object addresses the links."
::= { deviceLinkEntry 2 }
deviceLinkName OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object contains the name of the inserted line card.
If no line card exists, the name is Unknown."
::= { deviceLinkEntry 3 }
deviceLinkAlarm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object contains the collected alarms
It is used to convert alarm notifications
to SNMP traps.
Bits 0,1 and 2 are used for the Alarm Summary
Bit 5 is used to signify a loop state change of Ulaf-2 Desktop devices
Bit Alarm Description
0 UA Urgent alarm
1 NUA Non urgent alarm
2 AIS Alarm indication signal
3 unused
4 unused
5 loopback change (Ulaf-2)
"
::= { deviceLinkEntry 4 }
-------------------------------
-- added in V3.0
-------------------------------
deviceLinkLocalLtNt OBJECT-TYPE
SYNTAX INTEGER
{
lt(1),
nt(2),
unknown(254),
unsupported(255)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates whether the management system is connected to
an LT or an NT device.
1 LT Device is configured as LT
2 NT Device is configured as NT (NT local)
254 unknown value
255 unsupported variable for addressed device"
::= { deviceLinkEntry 5 }
deviceLinkLocalId OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the Firmware ID of the local device."
::= { deviceLinkEntry 6 }
deviceLinkFarId OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the Firmware ID of the far device."
::= { deviceLinkEntry 7 }
deviceLinkNumReg1 OBJECT-TYPE
SYNTAX INTEGER
{
none(1),
one(2),
two(3),
three(4),
four(5),
five(6),
six(7),
seven(8),
eight(9),
unknown(254),
unsupported(255)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates how many regenerators were detected in HDSL path 1.
1 None No regenerator found
2 One One regenerator found (section A or 1)
3 Two Two regenerators found (section B or 2)
4 Three Three regenerators found (section 3)
5 Four Four regenerators found (section 4)
6 Five Five regenerators found (section 5)
7 Six Six regenerators found (section 6)
8 Seven Seven regenerators found (section 7)
9 Eight Eight regenerators found (section 8)
254 unknown value
255 unsupported value"
::= { deviceLinkEntry 8 }
deviceLinkNumReg2 OBJECT-TYPE
SYNTAX INTEGER
{
none(1),
one(2),
two(3),
three(4),
four(5),
five(6),
six(7),
seven(8),
eight(9),
unknown(254),
unsupported(255)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates how many regenerators were detected in HDSL path 1.
1 None No regenerator found
2 One One regenerator found (section A or 1)
3 Two Two regenerators found (section B or 2)
4 Three Three regenerators found (section 3)
5 Four Four regenerators found (section 4)
6 Five Five regenerators found (section 5)
7 Six Six regenerators found (section 6)
8 Seven Seven regenerators found (section 7)
9 Eight Eight regenerators found (section 8)
254 unknown value
255 unsupported value"
::= { deviceLinkEntry 9 }
deviceLinkLocalModules OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Gives a short summary of which modules are installed in the local
device. This variable is bit coded as follows:
Bit 0 G.703 Interface installed
Bit 1 Data Interface installed
Bit 2 Alarm Module installed
Bit 3 Clock Module installed
Bit 4 Debug Module installed
Bit 5 Rps Module installed
Bit 6 unknown value (ignore bits 0-5)
Bit 7 unsupported value (ignore bits 0-5)"
::= { deviceLinkEntry 10 }
deviceLinkFarModules OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Gives a short summary of which modules are installed in the far
device. This variable is bit coded as follows:
Bit 0 G.703 Interface installed
Bit 1 Data Interface installed
Bit 2 Alarm Module installed
Bit 3 Clock Module installed
Bit 4 Debug Module installed
Bit 5 Rps Module installed
Bit 6 unknown value (ignore bits 0-5)
Bit 7 unsupported value (ignore bits 0-5)"
::= { deviceLinkEntry 11 }
deviceLinkLocalHwFabData OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the Mainboard fabrication data of the local device."
::= { deviceLinkEntry 12 }
deviceLinkFarHwFabData OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the Mainboard fabrication data of the far device."
::= { deviceLinkEntry 13 }
deviceLinkLocalG703FabData OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the G703 Module fabrication data of the local device."
::= { deviceLinkEntry 14 }
deviceLinkLocalDataFabData OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains the Data Module fabrication data of the local device."
::= { deviceLinkEntry 15 }
-------------------------------
-- added in V3.0
-------------------------------
deviceLinkLocalFeatureFlag OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(33))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains a map of features supported by the local device.
Byte 0-31 contain the bit-coded feature flags 0..255
Byte 32 contains information about the validity of the
previous 32 bytes.
1 Ok The information in bytes 0..31 is valid
254 unknown values
255 unsupported variable for addressed device"
::= { deviceLinkEntry 16 }
deviceLinkFarFeatureFlag OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(33))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains a map of features supported by the local device.
Byte 0-31 contain the bit-coded feature flags 0..255
Byte 32 contains information about the validity of the
previous 32 bytes.
1 Ok The information in bytes 0..31 is valid
254 unknown values
255 unsupported variable for addressed device"
::= { deviceLinkEntry 17 }
deviceLinkFarFeatureFlagState OBJECT-TYPE
SYNTAX INTEGER
{
ok(1),
tooEarly(2),
legacy(3),
unknown(254),
unsupported(255)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the state and validity of deviceLinkFarFeatureFlag.
1 Ok The values of farFeatureFlag is valid
2 TooEarly The variable was read before the LT could determine the farFeatureFlag values
3 Legacy The far device is an Ulaf-2 device and has no feature flag
254 unknown values
255 unsupported variable for addressed device"
::= { deviceLinkEntry 18 }
-------------------------------
-- added in V3.0
-------------------------------
deviceLinkSruFeatureFlag OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(33))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains a map of features supported by the local device.
Byte 0-31 contain the bit-coded feature flags 0..255
Byte 32 contains information about the validity of the
previous 32 bytes.
1 Ok The information in bytes 0..31 is valid
254 unknown values
255 unsupported variable for addressed device"
::= { deviceLinkEntry 19 }
deviceLinkNumReg3 OBJECT-TYPE
SYNTAX INTEGER
{
none(1),
one(2),
two(3),
three(4),
four(5),
five(6),
six(7),
seven(8),
eight(9),
unknown(254),
unsupported(255)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates how many regenerators were detected in xDSL path 3.
1 None No regenerator found
2 One One regenerator found (section A or 1)
3 Two Two regenerators found (section B or 2)
4 Three Three regenerators found (section 3)
5 Four Four regenerators found (section 4)
6 Five Five regenerators found (section 5)
7 Six Six regenerators found (section 6)
8 Seven Seven regenerators found (section 7)
9 Eight Eight regenerators found (section 8)
254 unknown value
255 unsupported value"
::= { deviceLinkEntry 20 }
deviceLinkNumReg4 OBJECT-TYPE
SYNTAX INTEGER
{
none(1),
one(2),
two(3),
three(4),
four(5),
five(6),
six(7),
seven(8),
eight(9),
unknown(254),
unsupported(255)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates how many regenerators were detected in xDSL path 4.
1 None No regenerator found
2 One One regenerator found (section A or 1)
3 Two Two regenerators found (section B or 2)
4 Three Three regenerators found (section 3)
5 Four Four regenerators found (section 4)
6 Five Five regenerators found (section 5)
7 Six Six regenerators found (section 6)
8 Seven Seven regenerators found (section 7)
9 Eight Eight regenerators found (section 8)
254 unknown value
255 unsupported value"
::= { deviceLinkEntry 21 }
--------------------------------------------------------------------------------
link OBJECT IDENTIFIER ::= { linksVers2 1 }
--------------------------------------------------------------------------------
linkConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF LinkConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { link 1 }
linkConfigEntry OBJECT-TYPE
SYNTAX LinkConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
INDEX { linkConfigPortIndex, linkConfigIndex }
::= { linkConfigTable 1 }
LinkConfigEntry ::=
SEQUENCE
{
linkConfigPortIndex INTEGER,
linkConfigIndex INTEGER,
performance INTEGER
}
linkConfigPortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object addresses the port number of the proxy agent"
::= { linkConfigEntry 1 }
linkConfigIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object addresses the line card number of the OMI
equipment."
::= { linkConfigEntry 2 }
performance OBJECT-TYPE
SYNTAX INTEGER
{
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object defines if the performance management is running
or not"
::= { linkConfigEntry 4}
END