mirror of
https://github.com/librenms/librenms.git
synced 2024-09-21 18:38:25 +00:00
11147d3bbf
* Extract DiscoveryItem and move some things to better places. Extract model class Fix up model construction. I have problem with construction... Makeshift model working. Switch constructor to factory. discover() and create() Support legacy discovery. Remove uneeded custom pollers Remove netonix custom detection as we try ucd on all os now. Add a few yaml procs. Fix a couple things. More processor discovery conversions Move Calix e7 to standard hrProcessorLoad, but it doesn't fully implement the HR-MIB, move things around to make it work. Add a few yaml procs. Fix a couple things. Correct some stupid mib stuff. Move more, drop php 5.3 Add netscaler which uses string indexes. Port fiberhome to yaml and use skip_values More conversions. BroadcomProcessorUsage Trait Serveriron and Ironware share some mibs. Create a common abstract os for them. Add yaml support for mib specification in each data entry Make legacy discover_processor() set 0 for hrDeviceIndex Untangle Dell switch OS processors Use use shared OS for groups if they don't have a specific group. fix silly mib mistake Make index optional Move HR and UCD to Traits and out of Processor. * forgot to update the fortiswitch index * Make sgos and avaya-ers match the old index. * fix comware test data * fix merge errors * fix dsm and remove pointless empty modules * file not found exception is in the wrong place. * Updated processor development docs
191 lines
5.1 KiB
Plaintext
191 lines
5.1 KiB
Plaintext
-- This module defines enterprise MIBs for VPN IKE info
|
|
--
|
|
-- Copyright (c) 1999-2004, Juniper Networks, Inc.
|
|
-- All rights reserved.
|
|
|
|
NETSCREEN-VPN-IKE-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
netscreenVpn, netscreenVpnMibModule
|
|
FROM NETSCREEN-SMI
|
|
Integer32, MODULE-IDENTITY, OBJECT-TYPE
|
|
FROM SNMPv2-SMI
|
|
DisplayString
|
|
FROM SNMPv2-TC
|
|
;
|
|
|
|
netscreenVpnIkeMibModule MODULE-IDENTITY
|
|
LAST-UPDATED "200405032022Z" -- May 03, 2004
|
|
ORGANIZATION
|
|
"Juniper Networks, Inc."
|
|
CONTACT-INFO
|
|
"Customer Support
|
|
|
|
1194 North Mathilda Avenue
|
|
Sunnyvale, California 94089-1206
|
|
USA
|
|
|
|
Tel: 1-800-638-8296
|
|
E-mail: customerservice@juniper.net
|
|
HTTP://www.juniper.net"
|
|
DESCRIPTION
|
|
"This module defines the object that are used to monitor
|
|
VPN IKE info"
|
|
REVISION "200405030000Z" -- May 03, 2004
|
|
DESCRIPTION
|
|
"Modified copyright and contact information"
|
|
REVISION "200403030000Z" -- March 03, 2004
|
|
DESCRIPTION
|
|
"Converted to SMIv2 by Longview Software"
|
|
REVISION "200311130000Z" -- November 13, 2003
|
|
DESCRIPTION
|
|
"Correct spelling mistake"
|
|
REVISION "200109280000Z" -- September 28, 2001
|
|
DESCRIPTION
|
|
"No comment"
|
|
REVISION "200105140000Z" -- May 14, 2001
|
|
DESCRIPTION
|
|
"Creation Date"
|
|
::= { netscreenVpnMibModule 3 }
|
|
|
|
NsVpnIkeEntry ::= SEQUENCE
|
|
{
|
|
nsVpnIkeIndex Integer32,
|
|
nsVpnIkeName DisplayString,
|
|
nsVpnIkeReplayProc INTEGER,
|
|
nsVpnIkeGWTun DisplayString,
|
|
nsVpnIkePh2ProOne DisplayString,
|
|
nsVpnIkePh2ProTwo DisplayString,
|
|
nsVpnIkePh2ProThree DisplayString,
|
|
nsVpnIkePh2ProFour DisplayString,
|
|
nsVpnIkeMonitorEnable INTEGER,
|
|
nsVpnIkeTransMode INTEGER,
|
|
nsVpnIkeVsys Integer32
|
|
}
|
|
|
|
nsVpnIke OBJECT IDENTIFIER ::= { netscreenVpn 3 }
|
|
|
|
nsVpnIkeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF NsVpnIkeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPSec supports the automated generation and negotiation of
|
|
keys and security associations using the Internet Key
|
|
Exchange(IKE) protocol. This table collects the IKE
|
|
configuration in NetScreen device."
|
|
::= { nsVpnIke 1 }
|
|
|
|
nsVpnIkeEntry OBJECT-TYPE
|
|
SYNTAX NsVpnIkeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each entry in the nsVpnIkeTable holds a set of configuration
|
|
parameters associated with an IKE."
|
|
INDEX
|
|
{ nsVpnIkeIndex }
|
|
::= { nsVpnIkeTable 1 }
|
|
|
|
nsVpnIkeIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value for ike table. Its value ranges between 0 and
|
|
65535 and may not be contiguous."
|
|
::= { nsVpnIkeEntry 1 }
|
|
|
|
nsVpnIkeName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each IKE configuration can have a readable name."
|
|
::= { nsVpnIkeEntry 2 }
|
|
|
|
nsVpnIkeReplayProc OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable Replay Protection"
|
|
::= { nsVpnIkeEntry 3 }
|
|
|
|
nsVpnIkeGWTun OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Remote Gateway Tunnel Name"
|
|
::= { nsVpnIkeEntry 4 }
|
|
|
|
nsVpnIkePh2ProOne OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Phase 2 Proposal one"
|
|
::= { nsVpnIkeEntry 5 }
|
|
|
|
nsVpnIkePh2ProTwo OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Phase 2 Proposal two"
|
|
::= { nsVpnIkeEntry 6 }
|
|
|
|
nsVpnIkePh2ProThree OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Phase 2 Proposal three"
|
|
::= { nsVpnIkeEntry 7 }
|
|
|
|
nsVpnIkePh2ProFour OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Phase 2 Proposal four"
|
|
::= { nsVpnIkeEntry 8 }
|
|
|
|
nsVpnIkeMonitorEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable to monitor VPN tunnel's link status."
|
|
::= { nsVpnIkeEntry 9 }
|
|
|
|
nsVpnIkeTransMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Transport Mode Enable (For L2TP-over-IPSec only)"
|
|
::= { nsVpnIkeEntry 10 }
|
|
|
|
nsVpnIkeVsys OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"vsys the configuration belongs to."
|
|
::= { nsVpnIkeEntry 11 }
|
|
|
|
END
|
|
|
|
|