librenms/mibs/huawei/HUAWEI-PORT
Adam Amstrong fea1d1ab80 add VRP. break some layout.
git-svn-id: http://www.observium.org/svn/observer/trunk@2567 61d68cd4-352d-0410-923a-c4978735b2b8
2011-09-23 15:20:11 +00:00

1541 lines
56 KiB
Plaintext
Raw Blame History

-- ==================================================================
-- Copyright (C) 2007 by HUAWEI TECHNOLOGIES. All rights reserved.
--
-- Description: HUAWEI PORT MIB
-- Reference:
-- Version: V1.0
-- History:
-- V1.0 2007-10-21 publish
-- ==================================================================
HUAWEI-PORT-MIB DEFINITIONS ::= BEGIN
IMPORTS
hwDatacomm
FROM HUAWEI-MIB
OBJECT-GROUP, MODULE-COMPLIANCE
FROM SNMPv2-CONF
InterfaceIndex
FROM IF-MIB
Integer32, OBJECT-TYPE, MODULE-IDENTITY ,Counter64
FROM SNMPv2-SMI
DisplayString,TruthValue,RowStatus
FROM SNMPv2-TC
EnabledStatus
FROM P-BRIDGE-MIB;
hwPortMIB MODULE-IDENTITY
LAST-UPDATED "200710210930Z"
ORGANIZATION
"Huawei Technologies Co.,Ltd."
CONTACT-INFO
"VRP Team Huawei Technologies Co.,Ltd.
Huawei Bld.,NO.3 Xinxi Rd.,
Shang-Di Information Industry Base,
Hai-Dian District Beijing P.R. China
http://www.huawei.com
Zip:100085
"
DESCRIPTION
"The private mib file includes the general extent
information of the device.hwDatacomm(157).hwPortMIB"
::= { hwDatacomm 157 }
hwPortMIBObjects OBJECT IDENTIFIER ::= { hwPortMIB 1 }
hwEthernet OBJECT IDENTIFIER ::= { hwPortMIBObjects 1 }
hwEthernetTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwEthernetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Indicates the physical attributes of the Ethernet interface.
This table lists the physical attributes of various Ethernet interfaces."
::= { hwEthernet 1 }
hwEthernetEntry OBJECT-TYPE
SYNTAX HwEthernetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Indicates the physical attributes of the Ethernet interface.
This table lists the physical attributes of various Ethernet interfaces."
INDEX { hwEthernetIfIndex }
::= { hwEthernetTable 1 }
HwEthernetEntry ::=
SEQUENCE{
hwEthernetIfIndex
InterfaceIndex,
hwEthernetLoopback
INTEGER,
hwEthernetPortType
INTEGER,
hwEthernetSpeedSet
INTEGER,
hwEthernetDuplex
INTEGER,
hwEthernetNegotiation
EnabledStatus,
hwEthernetPortTypeOperate
INTEGER,
hwEthernetClock
INTEGER,
hwEthernetFlagJ0Mode
INTEGER,
hwEthernetFlagJ0Value
Integer32,
hwEthernetFlagJ0Trace
OCTET STRING,
hwEthernetFlagJ1Mode
INTEGER,
hwEthernetFlagJ1Value
Integer32,
hwEthernetFlagJ1Trace
OCTET STRING,
hwEthernetFlagC2Value
Integer32,
hwEthernetUpHoldTime
Integer32,
hwEthernetDownHoldTime
Integer32,
hwEthernetSubinterfaceStatisticEnable
EnabledStatus
}
hwEthernetIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Interface index(es) of port(s) present on the device ."
::= { hwEthernetEntry 1 }
hwEthernetLoopback OBJECT-TYPE
SYNTAX INTEGER{
otherLoop(1),
stopLoopback(2),
local(3),
remote(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The local loopback of an Ethernet interface is used to test the interface itself.
If an interface works in a normal situation, disable the local loopback.
By default, stopLoopback is used."
::= { hwEthernetEntry 11 }
hwEthernetPortType OBJECT-TYPE
SYNTAX INTEGER{
other(1),
copper(2),
fiber(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the type of the Ethernet interface: an optical interface or an electrical interface."
::= { hwEthernetEntry 12 }
hwEthernetSpeedSet OBJECT-TYPE
SYNTAX INTEGER{
other(1),
speed10(2),
speed100(3),
speed1000(4),
speed10000(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the speed of the Ethernet interface. This parameter takes effect only on some Ethernet
electrical interfaces rather than optical interfaces. The parameter can be 10 M, 100 M, 1000 M,
10000 M."
::= { hwEthernetEntry 13 }
hwEthernetDuplex OBJECT-TYPE
SYNTAX INTEGER{
full(1),
half(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the duplex mode of the Ethernet interface. An electrical Ethernet interface can
work in half-duplex mode or full-duplex mode. An optical Ethernet can work only in full-duplex mode."
::= { hwEthernetEntry 14 }
hwEthernetNegotiation OBJECT-TYPE
SYNTAX EnabledStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the auto-negotiation mode of the Ethernet electrical interface. By default, auto-negotiation is enabled.
The three objects, hwEthernetSpeedSet, hwEthernetDuplex, and hwEthernetNegotiation are associated with each other.
If the auto-negotiation of hwEthernetNegotiation is enabled, the values of hwEthernetSpeedSet and hwEthernetDuplex are auto-negotiated.
If hwEthernetSpeedSet is set to a certain value, hwEthernetDuplex is modified to the default value full,
and hwEthernetNegotiation is automatically changed to disable. If the auto-negotiation of hwEthernetNegotiation is
enabled, hwEthernetDuplex cannot be set."
::= { hwEthernetEntry 15 }
hwEthernetPortTypeOperate OBJECT-TYPE
SYNTAX INTEGER{
other(1),
copper(2),
fiber100(3),
fiber1000(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the link type of the Ethernet interface. The type can be optical link or electrical link.
This parameter takes effect only on specific Ethernet interfaces."
::= { hwEthernetEntry 16 }
hwEthernetClock OBJECT-TYPE
SYNTAX INTEGER{
master(1),
slave(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the mode of the clock. The mode can be master or slave.
By default, the mode of a clock is slave. This parameter takes effect only on the WAN board."
::= { hwEthernetEntry 20 }
hwEthernetFlagJ0Mode OBJECT-TYPE
SYNTAX INTEGER{
j01ByteMode(1),
j016ByteMode(2),
j064ByteOrNullMode(3),
peer(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Before the 10 GE WAN board processes packets, the overhead byte must be configured on the interface.
The overhead byte for the SDH frame, j0: Set section trace byte
The default value is j016ByteMode(2)<29><>hwEthernetFlagJ0Trace <20><>NetEngine"
::= { hwEthernetEntry 21 }
hwEthernetFlagJ0Value OBJECT-TYPE
SYNTAX Integer32(0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"j01ByteMode Value. When hwEthernetFlagJ0Mode is set to j01ByteMode, this parameter takes effect."
::= { hwEthernetEntry 22 }
hwEthernetFlagJ0Trace OBJECT-TYPE
SYNTAX OCTET STRING(SIZE (0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set section trace byte.
When hwEthernetFlagJ0Mode is set to j016ByteMode or j064ByteOrNullMode, this variable takes effect.
When hwEthernetFlagJ0Mode is set to j016ByteMode, this variable is up to 15 characters trace byte.
When hwEthernetFlagJ0Mode is set to j064ByteOrNullMode, this variable is up to 64 characters trace byte."
::= { hwEthernetEntry 23 }
hwEthernetFlagJ1Mode OBJECT-TYPE
SYNTAX INTEGER{
j11ByteMode(1),
j116ByteMode(2),
j164ByteOrNullMode(3),
peer(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the overhead byte of the SDH frame. j1<6A><31>sets path trace byte.
The default value is j116ByteMode(2) hwEthernetFlagJ1Trace NetEngine."
::= { hwEthernetEntry 24 }
hwEthernetFlagJ1Value OBJECT-TYPE
SYNTAX Integer32(0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"j11ByteMode Value. When hwEthernetFlagJ1Mode is set to j11ByteMode, this parameter takes effect."
::= { hwEthernetEntry 25 }
hwEthernetFlagJ1Trace OBJECT-TYPE
SYNTAX OCTET STRING(SIZE (0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set path trace byte.
When hwEthernetFlagJ1Mode is set to j116ByteMode or j164ByteOrNullMode, this variable takes effect.
When hwEthernetFlagJ1Mode is set to j116ByteMode, this variable is up to 15 characters trace byte.
When hwEthernetFlagJ1Mode is set to j164ByteOrNullMode, this variable is up to 64 characters trace byte."
::= { hwEthernetEntry 26 }
hwEthernetFlagC2Value OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the overhead byte of the SDH frame.
c2: indicates the signal label byte. It is a hexdecimal value ranging from 00 to FF.
The default value is 0x02."
::= { hwEthernetEntry 27 }
hwEthernetUpHoldTime OBJECT-TYPE
SYNTAX Integer32(0..3000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the response time to the event that the port turns Up. The units of hwEthernetUpHoldTime is millisecond."
::= { hwEthernetEntry 31 }
hwEthernetDownHoldTime OBJECT-TYPE
SYNTAX Integer32 (0..1000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the response time to the event that the port turns Down. The units of hwEthernetDownHoldTime is millisecond."
::= { hwEthernetEntry 32 }
hwEthernetSubinterfaceStatisticEnable OBJECT-TYPE
SYNTAX EnabledStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable the statistical function of the sub-interface."
::= { hwEthernetEntry 33 }
hwPos OBJECT IDENTIFIER ::= { hwPortMIBObjects 2 }
hwPosTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwPosEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Indicates the physical attributes of the POS interface.
This table lists the physical attributes of the POS interface."
::= { hwPos 1 }
hwPosEntry OBJECT-TYPE
SYNTAX HwPosEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Indicates the physical attributes of the POS interface.
This table lists the physical attributes of the POS interface."
INDEX { hwPosIfIndex }
::= { hwPosTable 1 }
HwPosEntry ::=
SEQUENCE{
hwPosIfIndex
InterfaceIndex,
hwPosLinkProtocol
INTEGER,
hwPosFrameFormat
INTEGER,
hwPosLoopback
INTEGER,
hwPosScramble
EnabledStatus,
hwPosClock
INTEGER,
hwPosCrcVerifyCode
INTEGER,
hwPosFlagJ0Mode
INTEGER,
hwPosFlagJ0Value
Integer32,
hwPosFlagJ0Trace
OCTET STRING,
hwPosFlagJ1Mode
INTEGER,
hwPosFlagJ1Value
Integer32,
hwPosFlagJ1Trace
OCTET STRING,
hwPosFlagC2Value
Integer32
}
hwPosIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Interface index(es) of port(s) present on the device ."
::= { hwPosEntry 1 }
hwPosLinkProtocol OBJECT-TYPE
SYNTAX INTEGER {
ietf(1),
nonstandard(2),
hdlc(3),
ppp(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the link layer protocol of the POS interface.
By default, on a POS interface, PPP serves as the link layer protocol."
::= { hwPosEntry 11 }
hwPosFrameFormat OBJECT-TYPE
SYNTAX INTEGER{
sonet(1),
sdh(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the frame type of the POS interface.
By default, the frame type of the POS interface is SDH.
This variable identifies whether a SONET or a SDH signal is used across this interface."
::= { hwPosEntry 12 }
hwPosLoopback OBJECT-TYPE
SYNTAX INTEGER{
otherLoop(1),
stopLoopback(2),
local(3),
remote(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The local loopback of a POS interface is used to test the interface itself.
If an interface works in a normal situation, disable the local loopback.
By default, stopLoopback is used."
::= { hwPosEntry 13 }
hwPosScramble OBJECT-TYPE
SYNTAX EnabledStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the scramble function of payload. By default, the scramble function of payload is enabled."
::= { hwPosEntry 14 }
hwPosClock OBJECT-TYPE
SYNTAX INTEGER{
master(1),
slave(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether the clock is in master mode or slave mode.
By default, the clock is in slave mode."
::= { hwPosEntry 15 }
hwPosCrcVerifyCode OBJECT-TYPE
SYNTAX INTEGER{
crc16(1),
crc32(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the length of the CRC verity code. The default value is 32."
::= { hwPosEntry 16 }
hwPosFlagJ0Mode OBJECT-TYPE
SYNTAX INTEGER{
j01ByteMode(1),
j016ByteMode(2),
j064ByteOrNullMode(3),
peer(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the overhead byte of the SDH frame. j0: sets section trace byte.
The default value is j016ByteMode(2);hwPosFlagJ0Trace <20><>NetEngine."
::= { hwPosEntry 21 }
hwPosFlagJ0Value OBJECT-TYPE
SYNTAX Integer32(0..127)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the value of j01ByteMode. When hwPosFlagJ0Mode is set to j01ByteMode, hwPosFlagJ0Value takes effect."
::= { hwPosEntry 22 }
hwPosFlagJ0Trace OBJECT-TYPE
SYNTAX OCTET STRING(SIZE (0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set section trace byte.
When hwPosFlagJ0Mode is set to j016ByteMode or j064ByteOrNullMode, this variable takes effect.
When hwPosFlagJ0Mode is set to j016ByteMode, the value of this variable is up to 15 characters trace byte.
When hwPosFlagJ0Mode is set to j064ByteOrNullMode, the value of this variable is up to 64 characters trace byte."
::= { hwPosEntry 23 }
hwPosFlagJ1Mode OBJECT-TYPE
SYNTAX INTEGER{
j11ByteMode(1),
j116ByteMode(2),
j164ByteOrNullMode(3),
peer(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the overhead byte of the SDH frame. j1: sets path trace byte.
The default value is j116ByteMode(2);hwPosFlagJ1Trace <20><>NetEngine."
::= { hwPosEntry 24 }
hwPosFlagJ1Value OBJECT-TYPE
SYNTAX Integer32(0..127)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the value of j11ByteMode. When hwPosFlagJ1Mode is set to j11ByteMode, hwPosFlagJ1Value takes effect."
::= { hwPosEntry 25 }
hwPosFlagJ1Trace OBJECT-TYPE
SYNTAX OCTET STRING(SIZE (0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set path trace byte.
When hwPosFlagJ1Mode is set to j116ByteMode or j164ByteOrNullMode, this variable takes effect.
When hwPosFlagJ1Mode is set to j116ByteMode, this variable is up to 15 characters trace byte.
When hwPosFlagJ1Mode is set to j164ByteOrNullMode, this variable is up to 64 characters trace byte."
::= { hwPosEntry 26 }
hwPosFlagC2Value OBJECT-TYPE
SYNTAX Integer32(0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the overhead byte of the SDH frame.
c2: indicates the signal label byte. It is a hexdecimal value ranging from 00 to FF.
The default value is 0x02."
::= { hwPosEntry 27 }
hwCpos OBJECT IDENTIFIER ::= { hwPortMIBObjects 3 }
hwCposTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwCposEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Indicates the physical attributes of the CPOS interface.
This table lists the physical attributes of the CPOS interface."
::= { hwCpos 1 }
hwCposEntry OBJECT-TYPE
SYNTAX HwCposEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Indicates the physical attributes of the CPOS interface.
This table lists the physical attributes of the CPOS interface."
INDEX { hwCposIfIndex }
::= { hwCposTable 1 }
HwCposEntry ::=
SEQUENCE{
hwCposIfIndex
InterfaceIndex,
hwCposIfType
INTEGER,
hwCposClock
INTEGER,
hwCposFrameFormat
INTEGER,
hwCposMultiplex
INTEGER,
hwCposLoopback
INTEGER,
hwCposFlagJ0Mode
INTEGER,
hwCposFlagJ0Value
Integer32,
hwCposFlagJ0Trace
OCTET STRING,
hwCposFlagJ1Mode
INTEGER,
hwCposFlagJ1Value
Integer32,
hwCposFlagJ1Trace
OCTET STRING,
hwCposFlagC2Value
Integer32
}
hwCposIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Interface index(es) of port(s) present on the device ."
::= { hwCposEntry 1 }
hwCposClock OBJECT-TYPE
SYNTAX INTEGER{
master(1),
slave(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether the clock is in master mode or slave mode.
By default, the clock is in slave mode."
::= { hwCposEntry 11 }
hwCposIfType OBJECT-TYPE
SYNTAX INTEGER{
stm1(1),
stm16(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the interface type."
::= { hwCposEntry 12 }
hwCposFrameFormat OBJECT-TYPE
SYNTAX INTEGER{
sonet(1),
sdh(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the frame type of the CPOS interface. By default, the frame type of the CPOS interface is SDH."
::= { hwCposEntry 13 }
hwCposMultiplex OBJECT-TYPE
SYNTAX INTEGER{
au3(1),
au4(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the multiplex mode of the AUG. By default, the multiplex mode of the AUG is au-4."
::= { hwCposEntry 14 }
hwCposLoopback OBJECT-TYPE
SYNTAX INTEGER{
otherloop(1),
stopLoopback(2),
local(3),
remote(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the loopback function of the CPOS interface. By default, the loopback function is disabled."
::= { hwCposEntry 15 }
hwCposFlagJ0Mode OBJECT-TYPE
SYNTAX INTEGER{
j01ByteMode(1),
j016ByteMode(2),
j064ByteOrNullMode(3),
peer(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the overhead byte of the SDH frame. j0: sets section trace byte.
The default value is j016ByteMode(2);hwCposFlagJ0Trace NetEngine."
::= { hwCposEntry 21 }
hwCposFlagJ0Value OBJECT-TYPE
SYNTAX Integer32(0..127)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"j01ByteMode Value . When hwCposFlagJ0Mode is set to j01ByteMode, hwCposFlagJ0Value takes effect."
::= { hwCposEntry 22 }
hwCposFlagJ0Trace OBJECT-TYPE
SYNTAX OCTET STRING(SIZE (0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set section trace byte.
When hwCposFlagJ0Mode is set to j016ByteMode or j064ByteOrNullMode, this variable takes effect.
When hwCposFlagJ0Mode is set to j016ByteMode, this variable is up to 15 characters trace byte.
When hwCposFlagJ0Mode is set to j064ByteOrNullMode, this variable is up to 64 characters trace byte."
::= { hwCposEntry 23 }
hwCposFlagJ1Mode OBJECT-TYPE
SYNTAX INTEGER{
j11ByteMode(1),
j116ByteMode(2),
j164ByteOrNullMode(3),
peer(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the overhead byte of the SDH frame. j1: sets path trace byte.
The default value is j116ByteMode(2);hwCposFlagJ1Trace NetEngine."
::= { hwCposEntry 24 }
hwCposFlagJ1Value OBJECT-TYPE
SYNTAX Integer32(0..127)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the value of j11ByteMode. When hwCposFlagJ1Mode is set to j11ByteMode, hwCposFlagJ1Value takes effect."
::= { hwCposEntry 25 }
hwCposFlagJ1Trace OBJECT-TYPE
SYNTAX OCTET STRING(SIZE (0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Set path trace byte.
When hwCposFlagJ1Mode is set to j116ByteMode or j164ByteOrNullMode, this variable takes effect.
When hwCposFlagJ1Mode is set to j116ByteMode, this variable is a string up to 15 characters trace byte.
When hwCposFlagJ1Mode is set to j164ByteOrNullMode, this variable is a string up to 64 characters trace byte."
::= { hwCposEntry 26 }
hwCposFlagC2Value OBJECT-TYPE
SYNTAX Integer32(0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the overhead byte of the SDH frame.
c2: indicates the signal label byte. It is a hexdecimal value ranging from 00 to FF.
The default value is 22(0x16)."
::= { hwCposEntry 27 }
hwDs0ChannelBundle OBJECT IDENTIFIER ::= { hwPortMIBObjects 4 }
--
-- hwDs0ChannelBundleTable table
--
hwDs0ChannelBundleTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwDs0ChannelBundleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is used to bundle timeslots of CE1/CT1 interfaces."
::= { hwDs0ChannelBundle 1 }
hwDs0ChannelBundleEntry OBJECT-TYPE
SYNTAX HwDs0ChannelBundleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is used to bundle timeslots of CE1/CT1 interfaces."
INDEX { hwDs0ChannelBundleParentIfIndex, hwDs0ChannelBundleDs1ChannelId, hwDs0ChannelBundleId }
::= { hwDs0ChannelBundleTable 1 }
HwDs0ChannelBundleEntry ::=
SEQUENCE {
hwDs0ChannelBundleParentIfIndex InterfaceIndex,
hwDs0ChannelBundleDs1ChannelId Integer32,
hwDs0ChannelBundleId Integer32,
hwDs0ChannelBundleIfIndex InterfaceIndex,
hwDs0ChannelBundleTimeSlots OCTET STRING,
hwDs0ChannelBundleSpeed INTEGER,
hwDs0ChannelBundleRowStatus RowStatus
}
hwDs0ChannelBundleParentIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Indicates the index of the parent interface."
::= { hwDs0ChannelBundleEntry 1 }
hwDs0ChannelBundleDs1ChannelId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Indicates the channel ID."
::= { hwDs0ChannelBundleEntry 2 }
hwDs0ChannelBundleId OBJECT-TYPE
SYNTAX Integer32(0..30)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Indicates the index number of the channel set."
::= { hwDs0ChannelBundleEntry 3 }
hwDs0ChannelBundleIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the index of the serial interface formed by the timeslot binding."
::= { hwDs0ChannelBundleEntry 11 }
hwDs0ChannelBundleTimeSlots OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..61))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the number of the range of the timeslot to be bound.
The value is an integer ranging from 0 to 31. Multiple timeslots are
separated by ','. The range of timeslot is expressed by using '-'.
For E1 card mode:
If the timeslots are '0-31', it means unframed format,
If the timeslots are '0-30', it means framed format,
For T1 card mode:
If the timeslots are '0-23', it means unframed format,
If the timeslots are '0-22', it means framed format,
and hwDs0ChannelBundleDs1ChannelId and hwDs0ChannelBundleId should be zero."
::= { hwDs0ChannelBundleEntry 12 }
hwDs0ChannelBundleSpeed OBJECT-TYPE
SYNTAX INTEGER {
s56 (1),
s64 (2)
}
UNITS "kilo bytes"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Configures the mode to configure the timeslots.
If the parameter 56 k is selected, the timeslots are bound in the mode of N x 56 kbit/s.
If the parameter 64 k is selected, the timeslots are bound in the mode of N x 64 kbit/s.
The default value is 64kbit/s."
DEFVAL { 64 }
::= { hwDs0ChannelBundleEntry 13 }
hwDs0ChannelBundleRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This variable is used to create or delete an object."
::= { hwDs0ChannelBundleEntry 51 }
hwDs1 OBJECT IDENTIFIER ::= { hwPortMIBObjects 5 }
--
-- hwDs1Table table
--
hwDs1Table OBJECT-TYPE
SYNTAX SEQUENCE OF HwDs1Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table lists all E1/CE1 interfaces or T1/CT1 interfaces.
After the mode of E3/CE3 interfaces or T3/CT3 interfaces is set to channelized, this table can be used
to create E1/CE1, or T1/CT1, or E3/CE3, or T3/CT3 interfaces."
::= { hwDs1 1 }
hwDs1Entry OBJECT-TYPE
SYNTAX HwDs1Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table lists all E1/CE1 interfaces or T1/CT1 interfaces.
After the mode of E3/CE3 interfaces or T3/CT3 interfaces is set to channelized, this table can be used
to create E1/CE1, or T1/CT1, or E3/CE3, or T3/CT3 interfaces."
INDEX { hwDs1ParentIfIndex, hwDs1ChannelId, hwDs1IfIndex }
::= { hwDs1Table 1 }
HwDs1Entry ::=
SEQUENCE {
hwDs1ParentIfIndex InterfaceIndex,
hwDs1ChannelId Integer32,
hwDs1IfIndex InterfaceIndex,
hwDs1ChannelType INTEGER,
hwDs1IfType INTEGER,
hwDs1Channelized TruthValue,
hwDs1CodeType INTEGER,
hwDs1Clock INTEGER,
hwDs1FrameFormat INTEGER,
hwDs1Cable INTEGER,
hwDs1Loopback INTEGER,
hwDs1RowStatus RowStatus
}
hwDs1ParentIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Indicates the index of the parent interface."
::= { hwDs1Entry 1 }
hwDs1ChannelId OBJECT-TYPE
SYNTAX Integer32(0..63)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Indicates the channel ID."
::= { hwDs1Entry 2 }
hwDs1IfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Indicates the interface index."
::= { hwDs1Entry 3 }
hwDs1ChannelType OBJECT-TYPE
SYNTAX INTEGER{
t1 (1),
e1 (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the interface type. The type can be E1/CE1 or T1/CT1."
::= { hwDs1Entry 11 }
hwDs1IfType OBJECT-TYPE
SYNTAX INTEGER{
e3 (1),
t3 (2),
cpos (3),
atm (4),
none (255)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the interface tyep.
e3: is multiplexed by CE3 interfaces.
t3: is multiplexed by CT3 interfaces.
cpos: is multiplexed by CPOS interfaces.
atm: is multiplexed by ATM interfaces.
none: indicates the physical interface.
default:none"
DEFVAL { none }
::= { hwDs1Entry 12 }
hwDs1Channelized OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the working mode of the interface.
true: indicates the channelized mode.
false: indicates the clear channel mode.
The default is true."
DEFVAL { true }
::= { hwDs1Entry 13 }
hwDs1CodeType OBJECT-TYPE
SYNTAX INTEGER{
ami (1),
hdb3 (2),
b8zs (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the code type of the interface.
ami: is short for Alternate Mark Inversion.
hdb3: is short for High Density Bipolar of Order 3.
b8zs: is short for Bipolar with 8-Zero Substitution."
DEFVAL { hdb3 }
::= { hwDs1Entry 14 }
hwDs1Clock OBJECT-TYPE
SYNTAX INTEGER{
master (1),
slave (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the clock mode of the interface.
master: indicates that the clock works in master mode and uses the internal clock signal.
slave: indicates that the clock works in slave mode and uses the line clock signal."
::= { hwDs1Entry 15 }
hwDs1FrameFormat OBJECT-TYPE
SYNTAX INTEGER{
esf (1),
sf (2),
noCrc4 (3),
crc (4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the frame format of the interface.
crc4: indicates that the frame format is CRC4.
no-crc4: indicates that the frame format is no-CRC4.
sf: indicates that the frame format is Super Frame.
esf: indicates that the frame format is Extended Super Frame.
By default, the frame format of an E1 interface is no-crc4.
By default, the frame format of a T1 interface is esf."
::= { hwDs1Entry 16 }
hwDs1Cable OBJECT-TYPE
SYNTAX INTEGER{
long (1),
short (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The cable command takes effect only if the E1 interface card uses 75-ohm coaxial cable.
The default is short. If no cable is connected, this parameter is displayed as null."
DEFVAL { short }
::= { hwDs1Entry 17 }
hwDs1Loopback OBJECT-TYPE
SYNTAX INTEGER{
local (1),
remote (2),
payload (3),
cell (4),
none (255)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Enable the loopback function of the interface.
local: enables the local loopback on the interface.
remote: enables the remote loopback on the interface.
payload: enables the remote payload loopback on the interface.
cell: enables the local cell loopback. The local cell loopback is used to test the local physical chip."
DEFVAL { none }
::= { hwDs1Entry 18 }
hwDs1RowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This variable is used to create or delete an object."
::= { hwDs1Entry 51 }
hwDs3 OBJECT IDENTIFIER ::= { hwPortMIBObjects 6 }
--
-- hwDs3Table Table
--
hwDs3Table OBJECT-TYPE
SYNTAX SEQUENCE OF HwDs3Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table lists all E3/CE3 interfaces or all T3/CT3 interfaces."
::= { hwDs3 1 }
hwDs3Entry OBJECT-TYPE
SYNTAX HwDs3Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table lists all E3/CE3 interfaces or all T3/CT3 interfaces."
INDEX { hwDs3ParentIfIndex, hwDs3ChannelId, hwDs3IfIndex }
::= { hwDs3Table 1 }
HwDs3Entry ::=
SEQUENCE {
hwDs3ParentIfIndex InterfaceIndex,
hwDs3ChannelId Integer32,
hwDs3IfIndex InterfaceIndex,
hwDs3ChannelType INTEGER,
hwDs3IfType INTEGER,
hwDs3Channelized TruthValue,
hwDs3Clock INTEGER,
hwDs3FrameFormat INTEGER,
hwDs3Scramble TruthValue,
hwDs3Cable INTEGER,
hwDs3NationalBit INTEGER,
hwDs3Loopback INTEGER,
hwDs3CreateSerial TruthValue,
hwDs3RowStatus RowStatus
}
hwDs3ParentIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Indicates the index of the parent interface."
::= { hwDs3Entry 1 }
hwDs3ChannelId OBJECT-TYPE
SYNTAX Integer32(0..3)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Indicates the index of the parent interface."
::= { hwDs3Entry 2 }
hwDs3IfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Indicates the interface index."
::= { hwDs3Entry 3 }
hwDs3ChannelType OBJECT-TYPE
SYNTAX INTEGER{
t3 (1),
e3 (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the interface type. The type can be E3/CE3 or T3/CT3."
::= { hwDs3Entry 11 }
hwDs3IfType OBJECT-TYPE
SYNTAX INTEGER{
cpos (1),
none (255)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the parent interface type of the interface.
cpos: is multiplexed by CPOS interfaces.
none: indicates the interface is a physical interface.
The default is none."
DEFVAL { none }
::= { hwDs3Entry 12 }
hwDs3Channelized OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the working mode of the interface.
true: indicates the channelized mode.
false: indicates the clear channel mode.
The default is true."
DEFVAL { true }
::= { hwDs3Entry 13 }
hwDs3Clock OBJECT-TYPE
SYNTAX INTEGER{
master (1),
slave (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the clock mode of the interface.
master: indicates that the clock works in master mode and uses the internal clock signal.
slave: indicates that the clock works in slave mode and uses the line clock signal."
::= { hwDs3Entry 14 }
hwDs3FrameFormat OBJECT-TYPE
SYNTAX INTEGER{
g832Adm (1),
g751Adm (2),
g751Plcp (3),
cbitAdm (4),
cbitPlcp (5),
m23Adm (6),
m23Plcp (7)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the frame format of the interface."
::= { hwDs3Entry 15 }
hwDs3Scramble OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the scramble function of the interface.
true: enables the scramble function.
false: disables the scramble function.
The default is false."
DEFVAL { false }
::= { hwDs3Entry 16 }
hwDs3Cable OBJECT-TYPE
SYNTAX INTEGER{
long (1),
short (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The cable command takes effect only if the E3 interface card uses 75-ohm coaxial cable.
The default is short. If no cable is connected, this parameter is displayed as null."
DEFVAL { short }
::= { hwDs3Entry 17 }
hwDs3NationalBit OBJECT-TYPE
SYNTAX INTEGER{
n0 (1),
n1 (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Indicates the national bit of the E3/CE3 interface.
n0: indicates the national bit is 0 and the interface supports only the communication within a country.
n1: indicates the national bit is 1 and the interface supports the international communication. "
DEFVAL { n0 }
::= { hwDs3Entry 18 }
hwDs3Loopback OBJECT-TYPE
SYNTAX INTEGER{
local (1),
remote (2),
payload (3),
cell (4),
none (255)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Enable the loopback function of the interface.
local: enables the local loopback on the interface.
remote: enables the remote loopback on the interface.
payload: enables the remote payload loopback on the interface.
cell: enables the local cell loopback. The local cell loopback is used to test the local physical chip."
DEFVAL { none }
::= { hwDs3Entry 19 }
hwDs3CreateSerial OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Create serial interface from Ds3 interface.
True create serial interface.
False destroy serial interface.
"
DEFVAL { false }
::= { hwDs3Entry 20 }
hwDs3RowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This variable is used to create or delete an object."
::= { hwDs3Entry 51 }
hwBundleSerial OBJECT IDENTIFIER ::= { hwPortMIBObjects 7 }
--
-- hwBundleSerialTable Table
--
hwBundleSerialTable OBJECT-TYPE
SYNTAX SEQUENCE OF HwBundleSerialEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Indicates the attribute of the serial interface formed by timeslots.
This table lists the physical attributes of the serial interface."
::= { hwBundleSerial 1 }
hwBundleSerialEntry OBJECT-TYPE
SYNTAX HwBundleSerialEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Indicates the attribute of the serial interface formed by timeslots.
This table lists the physical attributes of the serial interface."
INDEX { hwBundleSerialIfIndex }
::= { hwBundleSerialTable 1 }
HwBundleSerialEntry ::=
SEQUENCE{
hwBundleSerialIfIndex
InterfaceIndex,
hwBundleSerialLinkProtocol
INTEGER,
hwBundleSerialTimerHold
Integer32,
hwBundleSerialLoopback
TruthValue,
hwBundleSerialCrcVerifyCode
INTEGER
}
hwBundleSerialIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Interface index(es) of serial(s) present on the device ."
::= { hwBundleSerialEntry 1 }
hwBundleSerialLinkProtocol OBJECT-TYPE
SYNTAX INTEGER {
ietf(1),
nonstandard(2),
hdlc(3),
ppp(4),
lapb(5),
atm(6),
tdm(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The link-protocol of interface. The serial(s) always use PPP as its link-protocol for default."
::= { hwBundleSerialEntry 11 }
hwBundleSerialTimerHold OBJECT-TYPE
SYNTAX Integer32(0..32767)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the interval for sending Keepalive packets from the serial interface to the peer.
The default is 10 seconds."
::= { hwBundleSerialEntry 12 }
hwBundleSerialLoopback OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"true: enables the loopback on the serial interface.
false: disables the loopback on the serial interface.
By default, the loopback on the serial interface is disabled."
DEFVAL { false }
::= { hwBundleSerialEntry 13 }
hwBundleSerialCrcVerifyCode OBJECT-TYPE
SYNTAX INTEGER{
crc16(1),
crc32(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the length of the CRC verify code. The default is 32."
::= { hwBundleSerialEntry 14 }
hwPortConformance OBJECT IDENTIFIER ::= { hwPortMIB 11 }
hwPortCompliances OBJECT IDENTIFIER ::= { hwPortConformance 1 }
hwPortCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for systems supporting
the HUAWEI-PORT-MIB."
MODULE
MANDATORY-GROUPS { hwEthernetObjectGroup, hwPosObjectGroup, hwCposObjectGroup, hwBundleSerialObjectGroup,
hwDs0ChannelBundleObjectGroup, hwDs1ObjectGroup, hwDs3ObjectGroup }
::= { hwPortCompliances 1 }
hwPortGroups OBJECT IDENTIFIER ::= { hwPortConformance 2 }
hwEthernetObjectGroup OBJECT-GROUP
OBJECTS{
hwEthernetLoopback
,
hwEthernetPortType
,
hwEthernetSpeedSet
,
hwEthernetDuplex
,
hwEthernetNegotiation
,
hwEthernetPortTypeOperate
,
hwEthernetClock
,
hwEthernetFlagJ0Mode
,
hwEthernetFlagJ0Value
,
hwEthernetFlagJ0Trace
,
hwEthernetFlagJ1Mode
,
hwEthernetFlagJ1Value
,
hwEthernetFlagJ1Trace
,
hwEthernetFlagC2Value
,
hwEthernetUpHoldTime
,
hwEthernetDownHoldTime
,
hwEthernetSubinterfaceStatisticEnable
}
STATUS current
DESCRIPTION
"The Port attribute group."
::= { hwPortGroups 1 }
hwPosObjectGroup OBJECT-GROUP
OBJECTS{
hwPosLinkProtocol
,
hwPosFrameFormat
,
hwPosLoopback
,
hwPosScramble
,
hwPosClock
,
hwPosCrcVerifyCode
,
hwPosFlagJ0Mode
,
hwPosFlagJ0Value
,
hwPosFlagJ0Trace
,
hwPosFlagJ1Mode
,
hwPosFlagJ1Value
,
hwPosFlagJ1Trace
,
hwPosFlagC2Value
}
STATUS current
DESCRIPTION
"The Port attribute group."
::= { hwPortGroups 2 }
hwCposObjectGroup OBJECT-GROUP
OBJECTS{
hwCposFrameFormat
,
hwCposMultiplex
,
hwCposClock
,
hwCposIfType
,
hwCposLoopback
,
hwCposFlagJ0Mode
,
hwCposFlagJ0Value
,
hwCposFlagJ0Trace
,
hwCposFlagJ1Mode
,
hwCposFlagJ1Value
,
hwCposFlagJ1Trace
,
hwCposFlagC2Value
}
STATUS current
DESCRIPTION
"The Port attribute group."
::= { hwPortGroups 3 }
hwDs0ChannelBundleObjectGroup OBJECT-GROUP
OBJECTS{
hwDs0ChannelBundleIfIndex
,
hwDs0ChannelBundleTimeSlots
,
hwDs0ChannelBundleSpeed
,
hwDs0ChannelBundleRowStatus
}
STATUS current
DESCRIPTION
"The Port attribute group."
::= { hwPortGroups 4 }
hwDs1ObjectGroup OBJECT-GROUP
OBJECTS{
hwDs1ChannelType
,
hwDs1IfType
,
hwDs1Channelized
,
hwDs1CodeType
,
hwDs1Clock
,
hwDs1FrameFormat
,
hwDs1Cable
,
hwDs1Loopback
,
hwDs1RowStatus
}
STATUS current
DESCRIPTION
"The Port attribute group."
::= { hwPortGroups 5 }
hwDs3ObjectGroup OBJECT-GROUP
OBJECTS{
hwDs3ChannelType
,
hwDs3IfType
,
hwDs3Channelized
,
hwDs3Clock
,
hwDs3FrameFormat
,
hwDs3Scramble
,
hwDs3Cable
,
hwDs3NationalBit
,
hwDs3Loopback
,
hwDs3CreateSerial
,
hwDs3RowStatus
}
STATUS current
DESCRIPTION
"The Port attribute group."
::= { hwPortGroups 6 }
hwBundleSerialObjectGroup OBJECT-GROUP
OBJECTS{
hwBundleSerialLinkProtocol
,
hwBundleSerialTimerHold
,
hwBundleSerialCrcVerifyCode
,
hwBundleSerialLoopback
}
STATUS current
DESCRIPTION
"The Port attribute group."
::= { hwPortGroups 7 }
END
--