ATEN-IPMI-MIB DEFINITIONS ::= BEGIN
|
|
|
|
--
|
|
-- Top-level infrastructure of the ATEN CORP. enterprise MIB tree
|
|
--
|
|
|
|
IMPORTS
|
|
NOTIFICATION-TYPE, MODULE-IDENTITY, OBJECT-TYPE, enterprises, Integer32, IpAddress FROM SNMPv2-SMI
|
|
DateAndTime FROM SNMPv2-TC;
|
|
|
|
aten MODULE-IDENTITY
|
|
LAST-UPDATED "200903201150Z"
|
|
ORGANIZATION "www.aten.com.tw"
|
|
CONTACT-INFO "email:shuyufu@aten.com.tw"
|
|
DESCRIPTION "Top-level infrastructure of the ATEN CORP. enterprise MIB tree"
|
|
REVISION "200903201150Z"
|
|
DESCRIPTION "First draft"
|
|
::= { enterprises 21317 }
|
|
|
|
--
|
|
-- ATEN CORP. enterprise-specific management objects
|
|
--
|
|
|
|
ipmi OBJECT IDENTIFIER ::= { aten 1 }
|
|
boardinfo OBJECT IDENTIFIER ::= { ipmi 5 }
|
|
hardwareinfo OBJECT IDENTIFIER ::= { ipmi 6 }
|
|
storage OBJECT IDENTIFIER ::= { ipmi 7 }
|
|
powerinfo OBJECT IDENTIFIER ::= { ipmi 14 }
|
|
fruinfo OBJECT IDENTIFIER ::= { ipmi 16 }
|
|
ntpinfo OBJECT IDENTIFIER ::= { ipmi 17 }
|
|
nvme OBJECT IDENTIFIER ::= { ipmi 19 }
|
|
network OBJECT IDENTIFIER ::= { ipmi 21 }
|
|
smtp OBJECT IDENTIFIER ::= { ipmi 22 }
|
|
|
|
--
|
|
-- MIB Module Object Types
|
|
--
|
|
sel OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Number of SELs"
|
|
::= { ipmi 2 }
|
|
|
|
sensorTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SensorEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of sensors. The number of entries is
|
|
given by the value of ifNumber."
|
|
::= { ipmi 3 }
|
|
|
|
sensorEntry OBJECT-TYPE
|
|
SYNTAX SensorEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing management information applicable to a
|
|
particular sensor."
|
|
INDEX { sensorNumber }
|
|
::= { sensorTable 1 }
|
|
|
|
SensorEntry ::=
|
|
SEQUENCE {
|
|
sensorNumber Integer32,
|
|
sensorReading OCTET STRING,
|
|
sensorPositiveHysteresis Integer32,
|
|
sensorNegativeHysteresis Integer32,
|
|
lncThreshold OCTET STRING,
|
|
lcThreshold OCTET STRING,
|
|
lnrThreshold OCTET STRING,
|
|
uncThreshold OCTET STRING,
|
|
ucThreshold OCTET STRING,
|
|
unrThreshold OCTET STRING,
|
|
eventAssertionEnable Integer32,
|
|
eventDeassertionEnable Integer32,
|
|
sensorIDString OCTET STRING
|
|
}
|
|
|
|
sensorNumber OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value, greater than zero, for each interface. It
|
|
is recommended that values are assigned contiguously
|
|
starting from 1. The value for each interface sub-layer
|
|
must remain constant at least from one re-initialization of
|
|
the entity's network management system to the next re-
|
|
initialization."
|
|
::= { sensorEntry 1 }
|
|
|
|
sensorReading OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A textual string containing information about the
|
|
interface. This string should include the name of the
|
|
manufacturer, the product name and the version of the
|
|
interface hardware/software."
|
|
::= { sensorEntry 2 }
|
|
|
|
sensorPositiveHysteresis OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of interface. Additional values for ifType are
|
|
assigned by the Internet Assigned Numbers Authority (IANA),
|
|
through updating the syntax of the IANAifType textual
|
|
convention."
|
|
::= { sensorEntry 3 }
|
|
|
|
sensorNegativeHysteresis OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The size of the largest packet which can be sent/received
|
|
on the interface, specified in octets. For interfaces that
|
|
are used for transmitting network datagrams, this is the
|
|
size of the largest network datagram that can be sent on the
|
|
interface."
|
|
::= { sensorEntry 4 }
|
|
|
|
lncThreshold OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the interface's current bandwidth in bits
|
|
per second. For interfaces which do not vary in bandwidth
|
|
or for those where no accurate estimation can be made, this
|
|
object should contain the nominal bandwidth. If the
|
|
bandwidth of the interface is greater than the maximum value
|
|
reportable by this object then this object should report its
|
|
maximum value (4,294,967,295) and ifHighSpeed must be used
|
|
to report the interace's speed. For a sub-layer which has
|
|
no concept of bandwidth, this object should be zero."
|
|
::= { sensorEntry 5 }
|
|
|
|
lcThreshold OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The interface's address at its protocol sub-layer. For
|
|
example, for an 802.x interface, this object normally
|
|
contains a MAC address. The interface's media-specific MIB
|
|
must define the bit and byte ordering and the format of the
|
|
value of this object. For interfaces which do not have such
|
|
an address (e.g., a serial line), this object should contain
|
|
an octet string of zero length."
|
|
::= { sensorEntry 6 }
|
|
|
|
lnrThreshold OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The desired state of the interface. The testing(3) state
|
|
indicates that no operational packets can be passed. When a
|
|
managed system initializes, all interfaces start with
|
|
ifAdminStatus in the down(2) state. As a result of either
|
|
explicit management action or per configuration information
|
|
retained by the managed system, ifAdminStatus is then
|
|
changed to either the up(1) or testing(3) states (or remains
|
|
in the down(2) state)."
|
|
::= { sensorEntry 7 }
|
|
|
|
|
|
|
|
uncThreshold OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current operational state of the interface. The
|
|
testing(3) state indicates that no operational packets can
|
|
be passed. If ifAdminStatus is down(2) then ifOperStatus
|
|
should be down(2). If ifAdminStatus is changed to up(1)
|
|
then ifOperStatus should change to up(1) if the interface is
|
|
ready to transmit and receive network traffic; it should
|
|
change to dormant(5) if the interface is waiting for
|
|
external actions (such as a serial line waiting for an
|
|
incoming connection); it should remain in the down(2) state
|
|
if and only if there is a fault that prevents it from going
|
|
to the up(1) state; it should remain in the notPresent(6)
|
|
state if the interface has missing (typically, hardware)
|
|
components."
|
|
::= { sensorEntry 8 }
|
|
|
|
ucThreshold OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime at the time the interface entered
|
|
its current operational state. If the current state was
|
|
entered prior to the last re-initialization of the local
|
|
network management subsystem, then this object contains a
|
|
zero value."
|
|
::= { sensorEntry 9 }
|
|
|
|
unrThreshold OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of octets received on the interface,
|
|
|
|
|
|
including framing characters.
|
|
|
|
Discontinuities in the value of this counter can occur at
|
|
re-initialization of the management system, and at other
|
|
times as indicated by the value of
|
|
ifCounterDiscontinuityTime."
|
|
::= { sensorEntry 10 }
|
|
|
|
eventAssertionEnable OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of packets, delivered by this sub-layer to a
|
|
higher (sub-)layer, which were not addressed to a multicast
|
|
or broadcast address at this sub-layer.
|
|
|
|
Discontinuities in the value of this counter can occur at
|
|
re-initialization of the management system, and at other
|
|
times as indicated by the value of
|
|
ifCounterDiscontinuityTime."
|
|
::= { sensorEntry 11 }
|
|
|
|
eventDeassertionEnable OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of packets, delivered by this sub-layer to a
|
|
higher (sub-)layer, which were addressed to a multicast or
|
|
broadcast address at this sub-layer.
|
|
|
|
Discontinuities in the value of this counter can occur at
|
|
re-initialization of the management system, and at other
|
|
times as indicated by the value of
|
|
ifCounterDiscontinuityTime.
|
|
|
|
This object is deprecated in favour of ifInMulticastPkts and
|
|
ifInBroadcastPkts."
|
|
::= { sensorEntry 12 }
|
|
|
|
sensorIDString OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"16-byte length field for displaying each available sensors' ID string."
|
|
::= { sensorEntry 13 }
|
|
|
|
powerStatus OBJECT-TYPE
|
|
SYNTAX INTEGER { poweroff(0), poweron(1) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Get and set the power status of system.
|
|
Set case:
|
|
0 : power off
|
|
1 : power on
|
|
2 : power reset"
|
|
::= { ipmi 4 }
|
|
|
|
coldResetBMC OBJECT-TYPE
|
|
SYNTAX Integer32 (1)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Cold reset the BMC."
|
|
::= { ipmi 8 }
|
|
|
|
bmcMajorVesion OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"BMC Major Vesion"
|
|
::= { boardinfo 1 }
|
|
|
|
bmcMinorVesion OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"BMC Minor Vesion"
|
|
::= { boardinfo 2 }
|
|
|
|
bmcBuildDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"BMC FW Build Date"
|
|
::= { boardinfo 3 }
|
|
|
|
biosVesion OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"BIOS Vesion"
|
|
::= { boardinfo 4 }
|
|
|
|
biosBuildDate OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"BIOS Build Date"
|
|
::= { boardinfo 5 }
|
|
|
|
hostName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(64))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"BMC Host Name"
|
|
::= { boardinfo 6 }
|
|
|
|
bmcBuildVesion OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"BMC Build Vesion"
|
|
::= { boardinfo 7 }
|
|
|
|
serialNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Motherboard Serial Number"
|
|
::= { hardwareinfo 1 }
|
|
|
|
cpuTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CpuEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of CPUs. The number of entries is
|
|
given by the number of CPUs."
|
|
::= { hardwareinfo 2 }
|
|
|
|
cpuEntry OBJECT-TYPE
|
|
SYNTAX CpuEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing management information applicable to a
|
|
particular CPU."
|
|
INDEX { cpuNumber }
|
|
::= { cpuTable 1 }
|
|
|
|
CpuEntry ::=
|
|
SEQUENCE {
|
|
cpuNumber Integer32,
|
|
processor OCTET STRING,
|
|
speed Integer32,
|
|
core Integer32,
|
|
coreActive Integer32,
|
|
manufacturer OCTET STRING
|
|
}
|
|
|
|
cpuNumber OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value, greater than zero, for each CPU. It
|
|
is recommended that values are assigned contiguously
|
|
starting from 1."
|
|
::= { cpuEntry 1 }
|
|
|
|
processor OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(64))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Processor name."
|
|
::= { cpuEntry 2 }
|
|
|
|
speed OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Processor speed (MHz)."
|
|
::= { cpuEntry 3 }
|
|
|
|
core OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of processor cores."
|
|
::= { cpuEntry 4 }
|
|
|
|
coreActive OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of active processor cores."
|
|
::= { cpuEntry 5 }
|
|
|
|
manufacturer OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(64))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"CPU Manufacturer"
|
|
::= { cpuEntry 6 }
|
|
|
|
dimmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DimmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of DIMMs. The number of entries is
|
|
given by the number of DIMMs."
|
|
::= { hardwareinfo 3 }
|
|
|
|
dimmEntry OBJECT-TYPE
|
|
SYNTAX DimmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing management information applicable to a
|
|
particular DIMM."
|
|
INDEX { dimmNumber }
|
|
::= { dimmTable 1 }
|
|
|
|
DimmEntry ::=
|
|
SEQUENCE {
|
|
dimmNumber Integer32,
|
|
dimmLocation OCTET STRING,
|
|
dimmMaxCapSpeed Integer32,
|
|
dimmOpSpeed Integer32,
|
|
dimmSize Integer32,
|
|
dimmSerialNo OCTET STRING,
|
|
dimmPartNo OCTET STRING,
|
|
dimmManufacturer OCTET STRING
|
|
}
|
|
|
|
dimmNumber OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value, greater than zero, for each DIMM. It
|
|
is recommended that values are assigned contiguously
|
|
starting from 1."
|
|
::= { dimmEntry 1 }
|
|
|
|
dimmLocation OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(64))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The location of this DIMM."
|
|
::= { dimmEntry 2 }
|
|
|
|
dimmMaxCapSpeed OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The max capable speed (MHz) of this DIMM."
|
|
::= { dimmEntry 3 }
|
|
|
|
dimmOpSpeed OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current operation speed (MHz) of this DIMM."
|
|
::= { dimmEntry 4 }
|
|
|
|
dimmSize OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The size (MBytes) of this DIMM."
|
|
::= { dimmEntry 5 }
|
|
|
|
dimmSerialNo OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The serial number of this DIMM."
|
|
::= { dimmEntry 6 }
|
|
|
|
dimmPartNo OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(64))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The serial number of this DIMM."
|
|
::= { dimmEntry 7 }
|
|
|
|
dimmManufacturer OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(64))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The manufacturer of this DIMM."
|
|
::= { dimmEntry 8 }
|
|
|
|
controllerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ControllerEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of raid controllers. The number of entries is
|
|
given by the number of controllers."
|
|
::= { storage 1 }
|
|
|
|
controllerEntry OBJECT-TYPE
|
|
SYNTAX ControllerEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing management information applicable to a
|
|
particular controller."
|
|
INDEX { controllerNumber }
|
|
::= { controllerTable 1 }
|
|
|
|
ControllerEntry ::=
|
|
SEQUENCE {
|
|
controllerNumber Integer32,
|
|
controllerProductName OCTET STRING,
|
|
serial OCTET STRING,
|
|
package OCTET STRING,
|
|
fwVersion OCTET STRING,
|
|
biosVersion OCTET STRING,
|
|
bootBlockVersion OCTET STRING,
|
|
batteryStatus Integer32,
|
|
pcieLocation Integer32,
|
|
pcieSlot Integer32
|
|
}
|
|
|
|
controllerNumber OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value, greater than zero, for each controller. It
|
|
is recommended that values are assigned contiguously
|
|
starting from 1."
|
|
::= { controllerEntry 1 }
|
|
|
|
controllerProductName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(96))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Product name of the controller."
|
|
::= { controllerEntry 2 }
|
|
|
|
serial OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Serial number of the controller."
|
|
::= { controllerEntry 3 }
|
|
|
|
package OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(96))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Package version of the controller."
|
|
::= { controllerEntry 4 }
|
|
|
|
fwVersion OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Firmware version of the controller."
|
|
::= { controllerEntry 5 }
|
|
|
|
biosVersion OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"BIOS version of the controller."
|
|
::= { controllerEntry 6 }
|
|
|
|
bootBlockVersion OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Boot block version of the controller."
|
|
::= { controllerEntry 7 }
|
|
|
|
batteryStatus OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Battery status of the controller.
|
|
0: Missing
|
|
1: Charging
|
|
2: Discharging
|
|
3: Optimal
|
|
4: Needs to be replaced"
|
|
::= { controllerEntry 8 }
|
|
|
|
pcieLocation OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PCIE location of the controller.
|
|
0: ONBOARD
|
|
1: RISER WIO Right
|
|
2: RISER WIO Left
|
|
3: RISER Ultra IO"
|
|
::= { controllerEntry 9 }
|
|
|
|
pcieSlot OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PCIE slot number of the controller."
|
|
::= { controllerEntry 10 }
|
|
|
|
nicTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF NicEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of NICs. The number of entries is
|
|
given by the number of NICs."
|
|
::= { ipmi 20 }
|
|
|
|
nicEntry OBJECT-TYPE
|
|
SYNTAX NicEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing management information applicable to a
|
|
particular NIC."
|
|
INDEX { nicNumber }
|
|
::= { nicTable 1 }
|
|
|
|
NicEntry ::=
|
|
SEQUENCE {
|
|
nicNumber Integer32,
|
|
nicName OCTET STRING,
|
|
nicMac OCTET STRING,
|
|
nicIpv4Addr IpAddress,
|
|
nicIpv6Addr OCTET STRING,
|
|
nicGateway OCTET STRING,
|
|
nicNetmask OCTET STRING,
|
|
nicFqdn OCTET STRING,
|
|
nicDns OCTET STRING,
|
|
nicSpeed Integer32,
|
|
nicDescript OCTET STRING,
|
|
nicStatus OCTET STRING
|
|
}
|
|
|
|
nicNumber OBJECT-TYPE
|
|
SYNTAX Integer32 (1..32)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value, greater than zero, for each NIC. It
|
|
is recommended that values are assigned contiguously
|
|
starting from 1."
|
|
::= { nicEntry 1 }
|
|
|
|
nicName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of the NIC."
|
|
::= { nicEntry 2 }
|
|
|
|
nicMac OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(17))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"MAC of the NIC."
|
|
::= { nicEntry 3 }
|
|
|
|
nicIpv4Addr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPv4 address of the NIC."
|
|
::= { nicEntry 4 }
|
|
|
|
nicIpv6Addr OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(45))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPv6 address of the NIC."
|
|
::= { nicEntry 5 }
|
|
|
|
nicGateway OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(45))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Gateway of the NIC."
|
|
::= { nicEntry 6 }
|
|
|
|
nicNetmask OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(45))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Netmask of the NIC."
|
|
::= { nicEntry 7 }
|
|
|
|
nicFqdn OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(256))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"FQDN of the NIC."
|
|
::= { nicEntry 8 }
|
|
|
|
nicDns OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(91))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DNS of the NIC."
|
|
::= { nicEntry 9 }
|
|
|
|
nicSpeed OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Speed of the NIC. (Unit: Mbps)"
|
|
::= { nicEntry 10 }
|
|
|
|
nicDescript OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Description of the NIC."
|
|
::= { nicEntry 11 }
|
|
|
|
nicStatus OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status of the NIC."
|
|
::= { nicEntry 12 }
|
|
|
|
phyHddTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HddEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of HDDs. The number of entries is
|
|
given by the number of HDDs."
|
|
::= { storage 2 }
|
|
|
|
hddEntry OBJECT-TYPE
|
|
SYNTAX HddEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing management information applicable to a
|
|
particular HDD."
|
|
INDEX { hddNumber }
|
|
::= { phyHddTable 1 }
|
|
|
|
HddEntry ::=
|
|
SEQUENCE {
|
|
hddNumber Integer32,
|
|
hddControllerNumber Integer32,
|
|
enclosureNumber Integer32,
|
|
status Integer32,
|
|
temperature Integer32,
|
|
capacity Integer32,
|
|
vendor OCTET STRING,
|
|
modelName OCTET STRING,
|
|
revision OCTET STRING,
|
|
sn OCTET STRING,
|
|
linkSpeed Integer32,
|
|
fwState Integer32,
|
|
otherErrCount Integer32,
|
|
predictedFailCount Integer32,
|
|
mediaErrCount Integer32
|
|
}
|
|
|
|
hddNumber OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value, greater than zero, for each HDD. It
|
|
is recommended that values are assigned contiguously
|
|
starting from 1."
|
|
::= { hddEntry 1 }
|
|
|
|
hddControllerNumber OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The controller that this HDD belongs to."
|
|
::= { hddEntry 2 }
|
|
|
|
enclosureNumber OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The enclosure that this HDD belongs to."
|
|
::= { hddEntry 3 }
|
|
|
|
status OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current status of the HDD.
|
|
1: present
|
|
0: not present"
|
|
::= { hddEntry 4 }
|
|
|
|
temperature OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current temperature of the HDD."
|
|
::= { hddEntry 5 }
|
|
|
|
capacity OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Capacity(GB) of the HDD. "
|
|
::= { hddEntry 6 }
|
|
|
|
vendor OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The vendor of the HDD."
|
|
::= { hddEntry 7 }
|
|
|
|
modelName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Model name of the HDD."
|
|
::= { hddEntry 8 }
|
|
|
|
revision OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Revision of the HDD."
|
|
::= { hddEntry 9 }
|
|
|
|
sn OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The serial number of the HDD."
|
|
::= { hddEntry 10 }
|
|
|
|
linkSpeed OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The link speed of the HDD.
|
|
0: not defined
|
|
1: 1.5Gb/s - SATA 150
|
|
2: 3.0Gb/s
|
|
3: 6.0Gb/s
|
|
4: 12.0Gb/s"
|
|
::= { hddEntry 11 }
|
|
|
|
fwState OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The firmware state of the HDD.
|
|
00: Unconfigured good drive
|
|
01: Unconfigured bad drive
|
|
02: Hot spare drive
|
|
16: Configured-good drive(data invalid)
|
|
17: Configured-bad drive (data invalid)
|
|
20: Configured-drive is rebuilding
|
|
24: Configured-drive is online
|
|
32: drive is getting copied
|
|
64: drive is exposed and controlled by host
|
|
128: UnConfigured - shielded
|
|
130: Hot Spare - shielded
|
|
144: Configured - shielded"
|
|
::= { hddEntry 12 }
|
|
|
|
otherErrCount OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Other error count of the HDD."
|
|
::= { hddEntry 13 }
|
|
|
|
predictedFailCount OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Predicted fail count of the HDD."
|
|
::= { hddEntry 14 }
|
|
|
|
mediaErrCount OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Media error Count of the HDD."
|
|
::= { hddEntry 15 }
|
|
|
|
|
|
logHddTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF VolumeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of volumes. The number of entries is
|
|
given by the number of volumes."
|
|
::= { storage 3 }
|
|
|
|
volumeEntry OBJECT-TYPE
|
|
SYNTAX VolumeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing management information applicable to a
|
|
particular volume."
|
|
INDEX { volNumber }
|
|
::= { logHddTable 1 }
|
|
|
|
VolumeEntry ::=
|
|
SEQUENCE {
|
|
volNumber Integer32,
|
|
volControllerNumber Integer32,
|
|
volStatus Integer32,
|
|
volCapacity Integer32,
|
|
priRaidLevel Integer32,
|
|
raidLevelQualifier Integer32,
|
|
secRaidLevel Integer32,
|
|
ldStripSize Integer32,
|
|
numDevices Integer32,
|
|
spanDepth Integer32,
|
|
state Integer32,
|
|
volName OCTET STRING
|
|
}
|
|
|
|
volNumber OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value, greater than zero, for each volume. It
|
|
is recommended that values are assigned contiguously
|
|
starting from 1."
|
|
::= { volumeEntry 1 }
|
|
|
|
volControllerNumber OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The controller that this HDD belongs to."
|
|
::= { volumeEntry 2 }
|
|
|
|
volStatus OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current status of the volume.
|
|
1: present
|
|
0: not present"
|
|
::= { volumeEntry 3 }
|
|
|
|
volCapacity OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Capacity(GB) of the volume."
|
|
::= { volumeEntry 4 }
|
|
|
|
priRaidLevel OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Primary raid level of the volume."
|
|
::= { volumeEntry 5 }
|
|
|
|
raidLevelQualifier OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Raid level qaulifier of the volume."
|
|
::= { volumeEntry 6 }
|
|
|
|
secRaidLevel OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Secondary raid level of the volume."
|
|
::= { volumeEntry 7 }
|
|
|
|
ldStripSize OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"LD strip size of the volume.
|
|
(per DDF: 4=8K, 5=16K, 7=64K, 11=1MB, etc.)"
|
|
::= { volumeEntry 8 }
|
|
|
|
numDevices OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"number of drives per span."
|
|
::= { volumeEntry 9 }
|
|
|
|
spanDepth OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Span depth of the volume."
|
|
::= { volumeEntry 10 }
|
|
|
|
state OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"State of the volume.
|
|
0: offline
|
|
1: partially degraded
|
|
2: degraded
|
|
3: optimal"
|
|
::= { volumeEntry 11 }
|
|
|
|
volName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(64))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the volume."
|
|
::= { volumeEntry 12 }
|
|
|
|
userTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UserEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of all users."
|
|
::= { ipmi 9 }
|
|
|
|
userInfo OBJECT-TYPE
|
|
SYNTAX UserEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing management information applicable to a
|
|
particular user."
|
|
INDEX { id }
|
|
::= { userTable 1 }
|
|
|
|
UserEntry ::=
|
|
SEQUENCE {
|
|
id Integer32,
|
|
username OCTET STRING,
|
|
password OCTET STRING,
|
|
privilege Integer32
|
|
}
|
|
|
|
id OBJECT-TYPE
|
|
SYNTAX Integer32 (1..15)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value for user ID, greater than zero."
|
|
::= { userInfo 1 }
|
|
|
|
username OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"User name."
|
|
::= { userInfo 2 }
|
|
|
|
password OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(20))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Password."
|
|
::= { userInfo 3 }
|
|
|
|
privilege OBJECT-TYPE
|
|
SYNTAX Integer32 (2..4)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"User privilege."
|
|
::= { userInfo 4 }
|
|
|
|
uid OBJECT-TYPE
|
|
SYNTAX Integer32 (0..1)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Get and set the UID status.
|
|
Get case:
|
|
0 : off
|
|
1 : on
|
|
Set case:
|
|
0 : off
|
|
1 : on"
|
|
::= { ipmi 10 }
|
|
|
|
|
|
|
|
psuNumber OBJECT-TYPE
|
|
SYNTAX Integer32 (0..8)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of PSUs"
|
|
::= { powerinfo 1 }
|
|
|
|
psuTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PsuEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of PSUs. The number of entries is
|
|
given by the number of PSUs."
|
|
::= { powerinfo 2 }
|
|
|
|
psuEntry OBJECT-TYPE
|
|
SYNTAX PsuEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing a particular PSU information."
|
|
INDEX { psuIndex }
|
|
::= { psuTable 1 }
|
|
|
|
PsuEntry ::=
|
|
SEQUENCE {
|
|
psuIndex Integer32,
|
|
psuStatus Integer32,
|
|
inputVoltage OCTET STRING,
|
|
inputCurrent OCTET STRING,
|
|
inputPower Integer32,
|
|
outputVoltage OCTET STRING,
|
|
outputCurrent OCTET STRING,
|
|
outputPower Integer32,
|
|
temperature1 Integer32,
|
|
temperature2 Integer32,
|
|
fanRPM1 Integer32,
|
|
fanRPM2 Integer32,
|
|
psuSerialNumber OCTET STRING
|
|
}
|
|
|
|
psuIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..8)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value, start from one, for each PSU. It is
|
|
recommended that values are assigned contiguously
|
|
starting from 1."
|
|
::= { psuEntry 1 }
|
|
|
|
psuStatus OBJECT-TYPE
|
|
SYNTAX INTEGER { fail(0), good(1) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PSU Status."
|
|
::= { psuEntry 2 }
|
|
|
|
inputVoltage OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PSU Input Voltage."
|
|
::= { psuEntry 3 }
|
|
|
|
inputCurrent OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PSU Input Current."
|
|
::= { psuEntry 4 }
|
|
|
|
inputPower OBJECT-TYPE
|
|
SYNTAX Integer32 (1..1048576)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PSU Input Power."
|
|
::= { psuEntry 5 }
|
|
|
|
outputVoltage OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PSU Output Voltage."
|
|
::= { psuEntry 6 }
|
|
|
|
outputCurrent OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PSU Output Current."
|
|
::= { psuEntry 7 }
|
|
|
|
outputPower OBJECT-TYPE
|
|
SYNTAX Integer32 (1..1048576)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PSU Output Power."
|
|
::= { psuEntry 8 }
|
|
|
|
temperature1 OBJECT-TYPE
|
|
SYNTAX Integer32 (1..256)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PSU Temperature1."
|
|
::= { psuEntry 9 }
|
|
|
|
temperature2 OBJECT-TYPE
|
|
SYNTAX Integer32 (1..256)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PSU Temperature2."
|
|
::= { psuEntry 10 }
|
|
|
|
fanRPM1 OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PSU Fan RPM1."
|
|
::= { psuEntry 11 }
|
|
|
|
fanRPM2 OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PSU Fan RPM2."
|
|
::= { psuEntry 12 }
|
|
|
|
psuSerialNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PSU Serial Number."
|
|
::= { psuEntry 13 }
|
|
|
|
--
|
|
-- FanMode MIB (15)
|
|
--
|
|
fanMode OBJECT-TYPE
|
|
SYNTAX INTEGER { standard(0), fullspeed(1), optimal(2), pue2optimal(3), heavyIO(4)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { ipmi 15 }
|
|
|
|
--
|
|
-- FRU MIB (16)
|
|
--
|
|
chassis OBJECT IDENTIFIER ::= { fruinfo 1 }
|
|
board OBJECT IDENTIFIER ::= { fruinfo 2 }
|
|
product OBJECT IDENTIFIER ::= { fruinfo 3 }
|
|
|
|
chassisType OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"FRU Chassis Type."
|
|
::= { chassis 1 }
|
|
|
|
chassisPartNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"FRU Chassis Part Number"
|
|
::= { chassis 2 }
|
|
|
|
chassisSerialNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"FRU Chassis Serial Number"
|
|
::= { chassis 3 }
|
|
|
|
boardLanguage OBJECT-TYPE
|
|
SYNTAX INTEGER { afar(1), abkhazian(2), afrikaans(3), amharic(4), arabic(5), assamese(6), aymara(7), azerbaijani(8), bashkir(9), byelorussian(10), bulgarian(11), bihari(12), bislama(13), bengali(14), tibetan(15), breton(16), catalan(17), corsican(18), czech(19), welsh(20), danish(21), german(22), bhutani(23), greek(24), english(25), esperanto(26), spanish(27), estonian(28), basque(29), persian(30), finnish(31), fiji(32), faeroese(33), french(34), frisian(35), irish(36), gaelic(37), galician(38), guarani(39), gujarati(40), hausa(41), hindi(42), croatian(43), hungarian(44), armenian(45), interlingua(46), interlingue(47), inupiak(48), indonesian(49), icelandic(50), italian(51), hebrew(52), japanese(53), yiddish(54), javanese(55), georgian(56), kazakh(57), greenlandic(58), cambodian(59), kannada(60), korean(61), kashmiri(62), kurdish(63), kirghiz(64), latin(65), lingala(66), laothian(67), lithuanian(68), lettish(69), malagasy(70), maori(71), macedonian(72), malayalam(73), mongolian(74), moldavian(75), marathi(76), malay(77), maltese(78), burmese(79), nauru(80), nepali(81), dutch(82), norwegian(83), occitan(84), oromo(85), oriya(86), punjabi(87), polish(88), pushto(89), portuguese(90), quechua(91), rhaeto-romance(92), kirundi(93), romanian(94), russian(95), kinyarwanda(96), sanskrit(97), sindhi(98), sangro(99), serbo-croatian(100), singhalese(101), slovak(102), slovenian(103), samoan(104), shona(105), somali(106), albanian(107), serbian(108), siswati(109), sesotho(110), sudanese(111), swedish(112), swahili(113), tamil(114), tegulu(115), tajik(116), thai(117), tigrinya(118), turkmen(119), tagalog(120), setswana(121), tonga(122), turkish(123), tsonga(124), tatar(125), twi(126), ukrainian(127), urdu(128), uzbek(129), vietnamese(130), volapuk(131), wolof(132), xhosa(133), yoruba(134), chinese(135), zulu(136) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"FRU Board Language"
|
|
::= { board 1 }
|
|
|
|
boardManufacturer OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"FRU Board Manufacturer"
|
|
::= { board 2 }
|
|
|
|
boardProductName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"FRU Board Product Name"
|
|
::= { board 3 }
|
|
|
|
boardSerialNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"FRU Board Serial Number"
|
|
::= { board 4 }
|
|
|
|
boardPartNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"FRU Board part Number"
|
|
::= { board 5 }
|
|
|
|
productLanguage OBJECT-TYPE
|
|
SYNTAX INTEGER { afar(1), abkhazian(2), afrikaans(3), amharic(4), arabic(5), assamese(6), aymara(7), azerbaijani(8), bashkir(9), byelorussian(10), bulgarian(11), bihari(12), bislama(13), bengali(14), tibetan(15), breton(16), catalan(17), corsican(18), czech(19), welsh(20), danish(21), german(22), bhutani(23), greek(24), english(25), esperanto(26), spanish(27), estonian(28), basque(29), persian(30), finnish(31), fiji(32), faeroese(33), french(34), frisian(35), irish(36), gaelic(37), galician(38), guarani(39), gujarati(40), hausa(41), hindi(42), croatian(43), hungarian(44), armenian(45), interlingua(46), interlingue(47), inupiak(48), indonesian(49), icelandic(50), italian(51), hebrew(52), japanese(53), yiddish(54), javanese(55), georgian(56), kazakh(57), greenlandic(58), cambodian(59), kannada(60), korean(61), kashmiri(62), kurdish(63), kirghiz(64), latin(65), lingala(66), laothian(67), lithuanian(68), lettish(69), malagasy(70), maori(71), macedonian(72), malayalam(73), mongolian(74), moldavian(75), marathi(76), malay(77), maltese(78), burmese(79), nauru(80), nepali(81), dutch(82), norwegian(83), occitan(84), oromo(85), oriya(86), punjabi(87), polish(88), pushto(89), portuguese(90), quechua(91), rhaeto-romance(92), kirundi(93), romanian(94), russian(95), kinyarwanda(96), sanskrit(97), sindhi(98), sangro(99), serbo-croatian(100), singhalese(101), slovak(102), slovenian(103), samoan(104), shona(105), somali(106), albanian(107), serbian(108), siswati(109), sesotho(110), sudanese(111), swedish(112), swahili(113), tamil(114), tegulu(115), tajik(116), thai(117), tigrinya(118), turkmen(119), tagalog(120), setswana(121), tonga(122), turkish(123), tsonga(124), tatar(125), twi(126), ukrainian(127), urdu(128), uzbek(129), vietnamese(130), volapuk(131), wolof(132), xhosa(133), yoruba(134), chinese(135), zulu(136) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"FRU Product Language"
|
|
::= { product 1 }
|
|
|
|
productManufacturer OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"FRU Product Manufacturer"
|
|
::= { product 2 }
|
|
|
|
productName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"FRU Product Name"
|
|
::= { product 3 }
|
|
|
|
productPartNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"FRU Product Part Number"
|
|
::= { product 4 }
|
|
|
|
productVersion OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"FRU Product Version"
|
|
::= { product 5 }
|
|
|
|
productSerialNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"FRU Product Serial Number"
|
|
::= { product 6 }
|
|
|
|
productAssetTag OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(63))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"FRU Product Asset Tag"
|
|
::= { product 7 }
|
|
--
|
|
-- NTP INFO MIB (17)
|
|
--
|
|
timeZone OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(5))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Get and set time zone.
|
|
Get/Set case:
|
|
-1200
|
|
-1100
|
|
-1000
|
|
-0930
|
|
-0900
|
|
-0800
|
|
-0700
|
|
-0600
|
|
-0500
|
|
-0430
|
|
-0400
|
|
-0330
|
|
-0300
|
|
-0230
|
|
-0200
|
|
-0100
|
|
+0000
|
|
+0100
|
|
+0200
|
|
+0300
|
|
+0330
|
|
+0400
|
|
+0430
|
|
+0500
|
|
+0530
|
|
+0545
|
|
+0600
|
|
+0630
|
|
+0700
|
|
+0800
|
|
+0900
|
|
+0930
|
|
+1000
|
|
+1030
|
|
+1100
|
|
+1130
|
|
+1200
|
|
+1300
|
|
+1400"
|
|
::= { ntpinfo 1 }
|
|
|
|
ntpEnable OBJECT-TYPE
|
|
SYNTAX INTEGER { disabled(0), enabled(1) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Get and set NTP status.
|
|
Get case:
|
|
0 : off
|
|
1 : on
|
|
Set case:
|
|
0 : off
|
|
1 : on"
|
|
::= { ntpinfo 2 }
|
|
|
|
primaryNTPServer OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(127))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Get and set primary NTP server"
|
|
::= { ntpinfo 3 }
|
|
|
|
secondaryNTPServer OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(127))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Get and set secondary NTP server"
|
|
::= { ntpinfo 4 }
|
|
|
|
dst OBJECT-TYPE
|
|
SYNTAX INTEGER { disabled(0), enabled(1) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Get and set daylight saving time status
|
|
Get case:
|
|
0 : off
|
|
1 : on
|
|
Set case:
|
|
0 : off
|
|
1 : on"
|
|
::= { ntpinfo 5 }
|
|
|
|
selTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SelEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table displays a record of critical system events from the monitored system."
|
|
::= { ipmi 18 }
|
|
|
|
selEntry OBJECT-TYPE
|
|
SYNTAX SelEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry event logs indicate the time when a critical condition occurred and the time it was resolved"
|
|
INDEX { selEid }
|
|
::= { selTable 1 }
|
|
|
|
SelEntry ::=
|
|
SEQUENCE {
|
|
selEid Integer32,
|
|
selTimeStamp DateAndTime,
|
|
selSensorName OCTET STRING,
|
|
selSensorType OCTET STRING,
|
|
selDescription OCTET STRING,
|
|
selRawData OCTET STRING
|
|
}
|
|
|
|
selEid OBJECT-TYPE
|
|
SYNTAX Integer32 (1..512)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"system event log EID"
|
|
::= { selEntry 1 }
|
|
|
|
selTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"System event log trigger time"
|
|
::= { selEntry 2 }
|
|
|
|
selSensorName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"System evnet log sensor name"
|
|
::= { selEntry 3 }
|
|
|
|
selSensorType OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(64))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"System evnet log sensor type"
|
|
::= { selEntry 4 }
|
|
|
|
selDescription OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(512))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"System evnet log description"
|
|
::= { selEntry 5 }
|
|
|
|
selRawData OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(20))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"System evnet log raw data"
|
|
::= { selEntry 6 }
|
|
|
|
|
|
alertTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AlertEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of all alerts."
|
|
::= { ipmi 11 }
|
|
|
|
alertInfo OBJECT-TYPE
|
|
SYNTAX AlertEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing management information applicable to a
|
|
particular alert."
|
|
INDEX { id }
|
|
::= { alertTable 1 }
|
|
|
|
AlertEntry ::=
|
|
SEQUENCE {
|
|
alertNo Integer32,
|
|
alertLevel OCTET STRING,
|
|
destinationAddress OCTET STRING
|
|
}
|
|
|
|
alertNo OBJECT-TYPE
|
|
SYNTAX Integer32 (1..16)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique value for alert ID, greater than zero."
|
|
::= { alertInfo 1 }
|
|
|
|
alertLevel OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(25))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Alert Level."
|
|
::= { alertInfo 2 }
|
|
|
|
destinationAddress OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(270))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Alert Level."
|
|
::= { alertInfo 3 }
|
|
|
|
--
|
|
-- Network MIB (21)
|
|
--
|
|
|
|
ipv4DNSServer OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPv4 dns server."
|
|
::= { network 1 }
|
|
|
|
ipv4Gateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPv4 gateway"
|
|
::= { network 2 }
|
|
|
|
ipv6DNSServer OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(45))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPv6 dns server."
|
|
::= { network 3 }
|
|
|
|
ipv6DUID OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPv6 DUID"
|
|
::= { network 4 }
|
|
|
|
dhcpv6State OBJECT-TYPE
|
|
SYNTAX INTEGER { stateless(0) , stateful(1) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DHCPv6 State"
|
|
::= { network 5 }
|
|
|
|
hostname OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"BMC hostname"
|
|
::= { network 6 }
|
|
|
|
dhcpEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER { disabled(0), enabled(1) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DHCP enabled"
|
|
::= { network 7 }
|
|
|
|
vlanIDEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER { disabled(0), enabled(1) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"VLan enabled"
|
|
::= { network 8 }
|
|
|
|
vlanID OBJECT-TYPE
|
|
SYNTAX Integer32 (1..4095)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Vlan ID"
|
|
::= { network 9 }
|
|
|
|
lanInterface OBJECT-TYPE
|
|
SYNTAX INTEGER { dedicated(0) , shared(1) ,failover(2)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"the current Lan interface"
|
|
::= { network 10 }
|
|
|
|
rmcpPort OBJECT-TYPE
|
|
SYNTAX Integer32 (1..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPMI port number"
|
|
::= { network 11 }
|
|
|
|
activeLanInterface OBJECT-TYPE
|
|
SYNTAX INTEGER { dedicated(0) , shared(1) ,failover(2)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"which Lan interface is active."
|
|
::= { network 12 }
|
|
|
|
dedicatedLanDuplex OBJECT-TYPE
|
|
SYNTAX INTEGER { unknown(0), fullduplex(1) , halfduplex(2)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Duplex Mode of the dedicated Lan"
|
|
::= { network 13 }
|
|
|
|
sharedLanDuplex OBJECT-TYPE
|
|
SYNTAX INTEGER { unknown(0), fullduplex(1) , halfduplex(2)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Duplex Mode of the share Lan"
|
|
::= { network 14 }
|
|
|
|
|
|
--
|
|
-- SMTP MIB (22)
|
|
--
|
|
|
|
smtpEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER { disabled(0), enabled(1) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"enable Email server "
|
|
::= { smtp 1 }
|
|
|
|
smtpServer OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Email server"
|
|
::= { smtp 2 }
|
|
|
|
smtpPort OBJECT-TYPE
|
|
SYNTAX Integer32 (1..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"the port number of the email server"
|
|
::= { smtp 3 }
|
|
|
|
smtpUsername OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"the username for email server's authentication"
|
|
::= { smtp 4 }
|
|
|
|
smtpSenderEmail OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"the sender's email address"
|
|
::= { smtp 5 }
|
|
|
|
--
|
|
-- MouseMode MIB (23)
|
|
--
|
|
mouseMode OBJECT-TYPE
|
|
SYNTAX INTEGER { absolute(1), relative(2), single(3) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"the port number of the email server"
|
|
::= { ipmi 23 }
|
|
|
|
--
|
|
-- BootOrder MIB (24)
|
|
--
|
|
sysBootOrder OBJECT-TYPE
|
|
SYNTAX INTEGER { none(0), pxe(1), hdd(2), diags(3), cdDvd(4), biosSetup(5), floppy(6), usbKey(7), usbHdd(8), usbFloppy(9), usbCD(10), uefiUsbKey(11), uefiCD(12), uefiHdd(13), uefiUsbHdd(14), uefiUsbCD(15) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"One time change system boot order."
|
|
::= { ipmi 24 }
|
|
|
|
|
|
--
|
|
-- NVMe MIB (19)
|
|
--
|
|
|
|
nvmeCtrlTbl OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF NVMeCtrlEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of NVMe controllers. The number of entries is
|
|
given by the number of controllers."
|
|
::= { nvme 1 }
|
|
|
|
nvmeCtrlEntry OBJECT-TYPE
|
|
SYNTAX NVMeCtrlEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing a particular NVMe controller information."
|
|
INDEX { nvmeCtrlPresent }
|
|
::= { nvmeCtrlTbl 1 }
|
|
|
|
NVMeCtrlEntry ::=
|
|
SEQUENCE {
|
|
nvmeCtrlPresent Integer32,
|
|
maxTemp Integer32,
|
|
maxSlotNum Integer32,
|
|
onboard Integer32,
|
|
driverIndex Integer32,
|
|
cpldVer OCTET STRING
|
|
}
|
|
|
|
nvmeCtrlPresent OBJECT-TYPE
|
|
SYNTAX INTEGER { absent(0), present(1) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NVMe controllor present or not."
|
|
::= { nvmeCtrlEntry 1 }
|
|
|
|
maxTemp OBJECT-TYPE
|
|
SYNTAX Integer32 (1..127)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum temperature from all existed NVMe drives."
|
|
::= { nvmeCtrlEntry 2 }
|
|
|
|
maxSlotNum OBJECT-TYPE
|
|
SYNTAX Integer32 (0..31)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum slot number at each group."
|
|
::= { nvmeCtrlEntry 3 }
|
|
|
|
onboard OBJECT-TYPE
|
|
SYNTAX INTEGER { no(0), yes(1) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NVMe controller type."
|
|
::= { nvmeCtrlEntry 4 }
|
|
|
|
driverIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (0..1)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NVMe BPN driver index."
|
|
::= { nvmeCtrlEntry 5 }
|
|
|
|
cpldVer OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"CPLD FW version of this NVMe controller."
|
|
::= { nvmeCtrlEntry 6 }
|
|
|
|
nvmeDriveTbl OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF NVMeDriveEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of NVMe drives. The number of entries is
|
|
given by the number of drives."
|
|
::= { nvme 2 }
|
|
|
|
nvmeDriveEntry OBJECT-TYPE
|
|
SYNTAX NVMeDriveEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing a particular NVMe drive information."
|
|
INDEX { slotId }
|
|
::= { nvmeDriveTbl 1 }
|
|
|
|
NVMeDriveEntry ::=
|
|
SEQUENCE {
|
|
slotId Integer32,
|
|
groupId Integer32,
|
|
nvmeDrivePresent Integer32,
|
|
locate Integer32,
|
|
save2Remove Integer32,
|
|
vmdMode Integer32,
|
|
temp Integer32,
|
|
classCode OCTET STRING,
|
|
vendorID OCTET STRING,
|
|
serialNum OCTET STRING,
|
|
modelNum OCTET STRING,
|
|
port0MaxLinkSpd OCTET STRING,
|
|
port0MaxLinkWidth OCTET STRING,
|
|
port1MaxLinkSpd OCTET STRING,
|
|
port1MaxLinkWidth OCTET STRING,
|
|
initPowerRequirement Integer32,
|
|
maxPowerRequirement Integer32
|
|
}
|
|
|
|
slotId OBJECT-TYPE
|
|
SYNTAX Integer32 (0..31)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NVMe Slot ID at one group."
|
|
::= { nvmeDriveEntry 1 }
|
|
|
|
groupId OBJECT-TYPE
|
|
SYNTAX Integer32 (0..7)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group ID at this slot."
|
|
::= { nvmeDriveEntry 2 }
|
|
|
|
nvmeDrivePresent OBJECT-TYPE
|
|
SYNTAX INTEGER { absent(0), present(1) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NVMe drive presence at this slot."
|
|
::= { nvmeDriveEntry 3 }
|
|
|
|
locate OBJECT-TYPE
|
|
SYNTAX INTEGER { dislocate(0), locate(1) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NVMe drive locate/dislocate status at this slot."
|
|
::= { nvmeDriveEntry 4 }
|
|
|
|
save2Remove OBJECT-TYPE
|
|
SYNTAX INTEGER { not-ready(0), ready(1) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NVMe drive save2Remove status at this slot."
|
|
::= { nvmeDriveEntry 5 }
|
|
|
|
vmdMode OBJECT-TYPE
|
|
SYNTAX INTEGER { vmd-off(0), vmd-on(1) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NVMe drive vmdMode status at this slot."
|
|
::= { nvmeDriveEntry 6 }
|
|
|
|
temp OBJECT-TYPE
|
|
SYNTAX Integer32 (0..127)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NVMe drive temperature at this slot."
|
|
::= { nvmeDriveEntry 7 }
|
|
|
|
classCode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NVMe drive class code at this slot."
|
|
::= { nvmeDriveEntry 8 }
|
|
|
|
vendorID OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NVMe drive class code at this slot."
|
|
::= { nvmeDriveEntry 9 }
|
|
|
|
serialNum OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(20))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NVMe drive serial number at this slot."
|
|
::= { nvmeDriveEntry 10 }
|
|
|
|
modelNum OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(40))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NVMe drive model number at this slot."
|
|
::= { nvmeDriveEntry 11 }
|
|
|
|
port0MaxLinkSpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NVMe drive port0 max link speed at this slot."
|
|
::= { nvmeDriveEntry 12 }
|
|
|
|
port0MaxLinkWidth OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NVMe drive port0 max link width at this slot."
|
|
::= { nvmeDriveEntry 13 }
|
|
|
|
port1MaxLinkSpd OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NVMe drive port1 max link speed at this slot."
|
|
::= { nvmeDriveEntry 14 }
|
|
|
|
port1MaxLinkWidth OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NVMe drive port1 max link width at this slot."
|
|
::= { nvmeDriveEntry 15 }
|
|
|
|
initPowerRequirement OBJECT-TYPE
|
|
SYNTAX Integer32 (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Initial power requirment (Watts)."
|
|
::= { nvmeDriveEntry 16 }
|
|
|
|
maxPowerRequirement OBJECT-TYPE
|
|
SYNTAX Integer32 (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum power requirment (Watts)."
|
|
::= { nvmeDriveEntry 17 }
|
|
|
|
guid NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION "GUID."
|
|
::= { ipmi 30 }
|
|
|
|