librenms/mibs/adic/ADIC-INTELLIGENT-STORAGE-MIB
Kevin Zink c1abbdc2c2
Add Quantum Scalar I6000 Tape Library (#14915)
* Add Quantum Scalar I6000 Tape Library

* Update quantum.yaml

Poller  deactivation removed

* Update quantum_scalari6000.json

---------

Co-authored-by: Tony Murray <murraytony@gmail.com>
2023-11-02 00:29:08 -05:00

1387 lines
51 KiB
Plaintext

-- Name: ADIC Enterprise Intelligent Storage MIB
-- Version: 1.25
--
-- **********************************************************
-- * *
-- * SMI v1 version *
-- * *
-- **********************************************************
--
-- Copyright (c) 2002-2014 Quantum Corporation
--
-- Revision History:
-- $Log: ADIC_INTELLIGENT_STORAGE_MIB.mib $
-- Revision 1.25 2015/12/07 10:26:49MST Bob Ackerman (backerman)
-- Add module identify so we can support dynamic module loading
-- Revision 1.24 2015/01/22 10:26:49MST Bob Ackerman (backerman)
-- Add power consumption to the power supply table
-- Revision 1.23 2014/03/06 10:26:49MST Carsten Prigge (cprigge)
-- Clean up MIB files and add power supply status
-- Revision 1.22 2013/09/16 10:26:49MST Carsten Prigge (cprigge)
-- Clean up MIB files to reduce errors from various MIB browsers
-- Revision 1.21 2006/11/01 10:13:06MST Darrel Somer (dsomer)
--
-- Revision 1.20 2006/11/01 10:12:08MST Darrel Somer (dsomer)
-- Add states to doorstatus to match master in mib project.
-- Revision 1.19 2004/12/09 15:26:29MST ihamadi
-- Removed extra double dashes from comments that turned off comment blocks
-- Revision 1.18 2004/12/06 13:10:34MST ihamadi
-- Updated Variable trapIntendedUsage has been added
-- Revision 1.32 2004/12/03 15:07:14MST dhawthorne
-- Added trapIntendedUsage to trap payload table
-- Revision 1.31 2004/03/04 17:22:59EST dhawthorne
-- Change unimplemented tables/variables to status "optional"
-- Comment out unimplemented traps
-- Revision 1.30 2004/01/08 17:40:38EST dhawthorne
-- Added componentIpAddress
-- Revision 1.29 2003/07/29 11:25:29EDT dhawthorne
-- Added virtual(10) to productLibraryClass enumeration
-- Revision 1.28 2003/05/22 15:59:12EDT dhawthorne
-- Change AdicGlobalId SIZE to 8 octets
-- Revision 1.27 2003/05/04 14:59:56EDT dhawthorne
-- Updated productVersion description clause.
-- Revision 1.26 2003/05/02 11:17:47EDT dhawthorne
-- Added libraryClassChange trap (#504)
-- Revision 1.25 2003/04/30 16:58:13EDT dhawthorne
-- Added componentAdded and componentRemoved traps.
-- Added AdicDriveStatus enumeration.
-- Revision 1.24 2003/04/08 14:07:08EDT dhawthorne
-- Add noData(7) to AdicSensorStatus
-- Revision 1.23 2003/04/03 19:04:07EST dhawthorne
-- Added notInstalled(6) to AdicSensorStatus enum.
-- Revision 1.22 2003/02/19 12:20:19EST dhawthorne
-- Changed componentId access to read-only. Removed "Persistent across boots" from description clause.
-- Revision 1.21 2003/02/19 11:38:34EST dhawthorne
-- Added componentGeoAddr objects to component table.
-- Revision 1.20 2003/01/07 12:34:33EST dhawthorne
-- Import TRAP-TYP from RFC-1215
-- Revision 1.19 2002/12/18 19:11:43EST dhawthorne
-- Added trapSummaryText field.
-- Revision 1.17 2002/12/18 16:02:31EST dhawthorne
-- Remove "Sensor" part from cooling fan trap definition.
-- Revision 1.16 2002/12/16 15:49:59EST dhawthorne
-- Added trap payload table
-- Added voltage, fan and temperature change traps
-- Revision 1.15 2002/12/12 11:05:26EST dhawthorne
-- Fixed syntax error - tried to check this into the main trunk, but
-- MKS created a branch instead (1.13.1.1)
-- Revision 1.13.1.1 2002/12/12 08:59:48MST dhawthorne
-- Fixed syntax error: missing comma in componentControl enumeration
-- Revision 1.13 2002/11/25 16:44:29MST dhawthorne
-- Added componentFirmwareVersion to componentTable.
-- Revision 1.12 2002/11/20 19:19:08EST dhawthorne
-- Removed "unknown" and "invalid" from componentControl enum
-- Shifted the remaining values to start at 1
-- Revision 1.11 2002/11/20 19:08:08EST dhawthorne
-- Added powerSupplyRatedVoltage and powerSupplyLocation
-- Revision 1.10 2002/11/20 18:03:16EST dhawthorne
-- Added AdicEnable Type Assignment
-- Revision 1.9 2002/11/20 15:53:41EST dhawthorne
-- added productSerialNumber
-- Revision 1.8 2002/10/28 18:07:38EST dhawthorne
-- Added RED identifier
-- Removed fan speed control
-- Revision 1.7 2002/10/08 16:42:18EDT dhawthorne
-- Renumbered temperature sensosr and cooling fan OIDs to remove gap (column 5 was missing)
-- Revision 1.6 2002/10/04 18:34:48EDT dhawthorne
-- Removed all enum or SIZE definitions from SEQUENCE clauses to satisfy jMIBc compiler
-- Revision 1.5 2002/09/25 17:41:15EDT dhawthorne
-- Commented out some Imports to quiet compiler warnings.
-- Revision 1.4 2002/09/25 17:16:06EDT dhawthorne
-- Corrected coolingFanVariableSpeed SYNTAX clause
-- Revision 1.3 2002/09/16 11:28:59EDT dhawthorne
-- In AdicComponentType enumeration, change dmcb(2) to cmb(2)
-- Revision 1.2 2002/08/19 12:33:01EDT dhawthorne
-- Re-wrote ADIC-ROBOTICS-MIB as a result of our 8/15/2002 design review
-- Revision 1.1 2002/08/12 09:53:03EDT jbruegger
-- Initial revision
-- Member imported to project e:/mks/projects/mib/mib.pj
--
--
ADIC-INTELLIGENT-STORAGE-MIB
--
-- **********************************************************
-- * *
-- * This MIB defines the ADIC OID tree hierarchy and the *
-- * set of all ADIC MIBs components may import as needed. *
-- * Of particular importance is the inventory group and *
-- * componentTable which provide a global way to list all *
-- * of the components in the product. Each component is *
-- * given a unique value of the componentId index; *
-- * componentId is imported by other ADIC MIBs and used as *
-- * an index, allowing management of multiple like *
-- * components through by a single proxy agent. *
-- * *
-- **********************************************************
DEFINITIONS ::= BEGIN
IMPORTS
enterprises, Counter, IpAddress
FROM RFC1155-SMI
OBJECT-TYPE
FROM RFC-1212
DisplayString
FROM RFC1213-MIB
TRAP-TYPE
FROM RFC-1215;
-- **********************************************************
-- * *
-- * ADIC Specific Object Identifiers *
-- * *
-- **********************************************************
-- Quantum (formerly ADIC) enterprises ID
quantum OBJECT IDENTIFIER ::= { enterprises 3764 }
-- The following are from "ADIC Storage MIB Design Document"
-- Version 1.0 2/16/2001 by Paul Rutherford
storage OBJECT IDENTIFIER ::= { quantum 1 } -- Paul mentions the storage OID but does not define it
-- Dean made up the iPenguin Product Identifier OID as per Paul's document
intelligent MODULE-IDENTITY
LAST-UPDATED "201509240000Z"
ORGANIZATION "Quantum Corporation"
CONTACT-INFO
" Quantum Corporation
224 Airport Parkway, Suite 300
San Jose, CA 95110
Tel: +1 800 284-5101
E-mail: support@quantum.com"
DESCRIPTION
"This MIB provides Tape Library product information."
REVISION "201509240000Z"
DESCRIPTION
"MIB update as of September 2015"
::= { storage 1 }
-- Standard product info for all products
productAgentInfo OBJECT IDENTIFIER ::= { intelligent 10 }
-- Global data that pertains to the iPenguin as a whole
globalData OBJECT IDENTIFIER ::= { intelligent 20 }
-- iPenguin components
components OBJECT IDENTIFIER ::= { intelligent 30 }
software OBJECT IDENTIFIER ::= { intelligent 100 }
hardware OBJECT IDENTIFIER ::= { intelligent 200 }
powerAndCooling OBJECT IDENTIFIER ::= { hardware 200 }
sml OBJECT IDENTIFIER ::= { intelligent 300 }
network OBJECT IDENTIFIER ::= { intelligent 400 }
notification OBJECT IDENTIFIER ::= { intelligent 500 }
--Type assignments
-- Current MIB version
AdicMibVersion ::= DisplayString (SIZE(0..40))
-- a truth value
Boolean ::= INTEGER { true(1), false(2) }
-- Runtime Error Detection Identifier
AdicREDIdentifier ::= Counter
AdicEnable ::= INTEGER { enabled(1), disabled(2) }
AdicAgentStatus ::= INTEGER { other(1), unknown(2), ok(3), non-critical(4), critical(5), non-recoverable(6) }
AdicOnlineStatus ::= INTEGER { online(1), offline(2), shutdown(3) }
AdicVaryStatus ::= INTEGER { variedOn(1), variedOff(2), inTransition(3) }
AdicGlobalId ::= OCTET STRING (SIZE(8))
AdicComponentType ::= INTEGER { mcb(1), cmb(2), fcIoBlade(3), scsiIoBlade(4), rcu(5), networkChassis(6),
libaryModule(7), powerSupply(8), eeb(9), hdc(10) }
AdicInterfaceType ::= INTEGER { parallelSCSI(1), fibreChannel(2), Other(3), mixedScsiAndFc(4) }
-- Power and Cooling related type definitions
-- These describe sensor voltage, temperature, fan RPMs, etc. properties and states
AdicSensorStatus ::= INTEGER { nominal(1), warningLow(2), warningHigh(3), alarmLow(4), alarmHigh(5), notInstalled(6), noData(7) }
AdicVoltageType ::= INTEGER { dc(1), ac(2) }
AdicPowerSupplyStatus ::= INTEGER { unknown(1), notInstalled(2), ok(3), poweredOff(4), failed(5) }
AdicTrapSeverity ::= INTEGER { emergency(1), alarm(2), warning(3), notice(4), informational(5) }
AdicDoorStatus ::= INTEGER { open(1), closed(2), closedAndLocked(3), closedAndUnlocked(4), controllerFailed(5), notInstalled(6), noData(7) }
AdicDriveStatus ::= INTEGER { idle(1), loading(2), ejecting(3), inserted(4), removed(5), notInstalled(6), noData(7) }
AdicTowerStatus ::= INTEGER { open(1), closed(2), closedAndVariedOn(3), closedAndVariedOff(4), controllerFailed(5), notInstalled(6), noData(7) }
-- Row Status Object
RowStatus ::= INTEGER { active(1), -- See RFC 2579
notInService(2), -- for complete
notReady(3), -- description
createAndGo(4), -- of RowStatus
createAndWait(5), -- Syntax
destroy(6) }
-- AdicDateAndTime is identical to the SMIv2 DateAndTime Textual Convention
-- It is defined here because we maintain compatibility with strict SMIv1
-- MIB compilers, which may not allow the DateAndTime Textual Convention
-- to be imported
-- Octet 1 and 2 - Year ( 0 ... 65536 ) in network byte order
-- Octet 3 - Month ( 1 ... 12 )
-- Octet 4 - Day ( 1 ... 31 )
-- Octet 5 - Hour (0 ... 23 )
-- Octet 6 - Minute ( 0 ... 59 )
-- Octet 7 - Seconds ( 0 ... 60 ) [ Use 60 for leap second ]
-- Octet 8 - Deci-seconds ( 0 ... 9 )
-- Octet 9 - Direction from UTC ( '+' or '-' )
-- Octet 10 - Hours from UTC ( 0 ... 11 )
-- Octet 11 - Minutes from UTC ( 0 ... 59 )
AdicDateAndTime ::= OCTET STRING (SIZE(8|11))
-- **********************************************************
-- * *
-- * ADIC Standard productAgentInfo Group Objects *
-- * *
-- **********************************************************
productMibVersion OBJECT-TYPE
SYNTAX AdicMibVersion
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MIB version identifier."
::= { productAgentInfo 1 }
productSnmpAgentVersion OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"SNMP agent version identifier."
::= { productAgentInfo 2 }
productName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Name of ADIC branded product. Uniquely identifies
the product, independent of OEM."
::= { productAgentInfo 3 }
productDisplayName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Name of this agent for display purposes. May
be customized for OEM."
::= { productAgentInfo 4 }
productDescription OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A short description of this SNMP agent."
::= { productAgentInfo 5 }
productVendor OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Name of the product vendor or OEM."
::= { productAgentInfo 6 }
productVersion OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"String Format: MNNO.TVBBBPP
Examples
1. 091a.TR054
Version 0.91, build 54 of the RCS test code for ADIC
2. 100A.GM052
Version 1.00, build 52 of the MCB GA candidate code for ADIC
M Major version number
NN Minor version number
O OEM (Uppercase when release candidate, otherwise lowercase)
A/a - ADIC
Others - Reserved)
T Target
G - GA Candidate Release (labeled build that is a release candidate)
T - Test build (labeled build used for formal testing)
D - Dev build (labeled build used for unit testing)
(lower case) - specifies developer of a local build
V Variant
S - System
R - RCS
M - MCB
BBB Build number (3 digit sequential number specifying exact build)
PP Patch Number (Optional alphanumeric characters denoting patch
level of this build if necessary)"
::= { productAgentInfo 7 }
productDisplayVersion OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The version identifier according to the vendor or OEM."
::= { productAgentInfo 8 }
productLibraryClass OBJECT-TYPE
SYNTAX INTEGER { basic(1), intelligent(2), virtual(10) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Basic library includes minimal connectivity hardware.
Intelligent library includes SAN appliances and value-added
features."
::= { productAgentInfo 9 }
productSerialNumber OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The serial number of the physical library."
::= { productAgentInfo 10 }
-- **********************************************************
-- * *
-- * ADIC Standard globalData Group Objects *
-- * *
-- **********************************************************
agentGlobalStatus OBJECT-TYPE
SYNTAX AdicAgentStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current overall status of the agent."
::= { globalData 1 }
agentLastGlobalStatus OBJECT-TYPE
SYNTAX AdicAgentStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The status before the current status which
induced an initiative to issue a global status
change trap."
::= { globalData 2 }
agentTimeStamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The last time that the agent values have been updated.
Universal time in seconds since UTC 1/1/70."
::= { globalData 3 }
agentGetTimeOut OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Suggested time out in milliseconds for how long
an SNMP management application should wait while
attempting to poll the SNMP agent."
::= { globalData 4 }
agentModifiers OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Agent functional modifiers, when set the modifier is
active.
-----------------------------------------------------
Bit 3 => Agent in debug mode.
-----------------------------------------------------
All other bits are product specific."
::= { globalData 5 }
agentRefreshRate OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Rate in seconds at which the agent cached data is
being updated."
::= { globalData 6 }
-- The Component table contains general information on the iPenguin's
-- components, particularly the unique identifier used to identify each
-- component in this MIB.
componentTable OBJECT-TYPE
SYNTAX SEQUENCE OF ComponentEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"General information about the system's components, including the
unique identifiers. The structure this table is based on the
Fibre Alliance MIB connUnitEntry."
::= { components 10 }
componentEntry OBJECT-TYPE
SYNTAX ComponentEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A component entry containing objects for a
particular component."
INDEX { componentId }
::= { componentTable 1 }
ComponentEntry ::=
SEQUENCE {
componentId AdicGlobalId,
componentType AdicComponentType,
componentDisplayName DisplayString,
componentInfo DisplayString,
componentLocation DisplayString,
componentVendor DisplayString,
componentSn DisplayString,
componentStatus INTEGER,
componentControl INTEGER,
componentREDId AdicREDIdentifier,
componentFirmwareVersion DisplayString,
componentGeoAddrAisle INTEGER,
componentGeoAddrFrame INTEGER,
componentGeoAddrRack INTEGER,
componentGeoAddrChassis INTEGER,
componentGeoAddrBlade INTEGER,
componentIpAddress IpAddress
}
componentId OBJECT-TYPE
SYNTAX AdicGlobalId
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The unique identification for this component
among those within this proxy domain."
::= { componentEntry 1 }
componentType OBJECT-TYPE
SYNTAX AdicComponentType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of this component."
::= { componentEntry 2 }
componentDisplayName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..79))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Name of this component for display purposes.
Different OEMs may have different display names for
the same ADIC product."
::= { componentEntry 3 }
componentInfo OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A display string containing information
about this component."
::= { componentEntry 4 }
componentLocation OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..79))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Location information for this component."
::= { componentEntry 5 }
componentVendor OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..79))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Name vendor of this component."
::= { componentEntry 6 }
componentSn OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..79))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The serial number for this component."
::= { componentEntry 7 }
componentStatus OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
unused(2), -- cannot report status
ok(3), -- available for meaningful work
warning(4), -- something needs attention
failed(5) -- something has failed
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Overall status of the component."
::= { componentEntry 8 }
componentControl OBJECT-TYPE
SYNTAX INTEGER {
resetColdStart(1),
resetWarmStart(2),
offline(3),
online(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object is used to control the addressed
connUnit.
NOTE: 'Cold Start' and 'Warm Start'
are as defined in MIB II and are not meant
to be a factory reset.
resetColdStart:
the addressed unit performs
a 'Cold Start' reset.
resetWarmStart:
the addressed unit performs
a 'Warm Start' reset.
offline:
the addressed unit puts itself into
an implementation dependant 'offline' state.
online:
the addressed unit puts itself into an
implementation dependant 'online' state."
::= { componentEntry 9 }
componentREDId OBJECT-TYPE
SYNTAX AdicREDIdentifier
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Runtime Error Detection identifier for this component."
::= { componentEntry 10 }
componentFirmwareVersion OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Firmware version (or level) for this component."
::= { componentEntry 11 }
componentGeoAddrAisle OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The aisle number where this component is located.
A negative value indicates that an aisle number
is not applicable to this component."
::= { componentEntry 12 }
componentGeoAddrFrame OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The frame number where this component is located.
A negative value indicates that a frame number is
not applicable to this component."
::= { componentEntry 13 }
componentGeoAddrRack OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The rack number where this component is located.
A negative value indicates that a rack number is
not applicable to this component."
::= { componentEntry 14 }
componentGeoAddrChassis OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The chassis number where this component is located.
A negative value indicates that a chassis number is
not applicable to this component."
::= { componentEntry 15 }
componentGeoAddrBlade OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The blade number within the network chasis where
this component is located. A negative value
indicates that a blade number is not applicable
to this component."
::= { componentEntry 16 }
componentIpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"IP address of this component. If the component
has no IP address, this object returns 0.0.0.0.
The address may refer to an internal network not
accessible to an external management application."
::= { componentEntry 17 }
-- **********************************************************
-- * *
-- * Power and Cooling Group *
-- * *
-- * This group and the objects defined within it are *
-- * intended to aggregate Power and Cooling information *
-- * from all sub-components in the library. *
-- * *
-- **********************************************************
-- The Power Supply table contains one entry for every power supply in
-- the library
powerSupplyTable OBJECT-TYPE
SYNTAX SEQUENCE OF PowerSupplyEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table provides power supply information."
::= { powerAndCooling 10 }
powerSupplyEntry OBJECT-TYPE
SYNTAX PowerSupplyEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry contains the information for a
specific power supply."
INDEX { componentId, powerSupplyIndex }
::= { powerSupplyTable 1 }
PowerSupplyEntry ::=
SEQUENCE { powerSupplyIndex INTEGER,
powerSupplyName DisplayString,
powerSupplyWattage INTEGER,
powerSupplyType AdicVoltageType,
powerSupplyREDId AdicREDIdentifier,
powerSupplyRatedVoltage INTEGER,
powerSupplyLocation DisplayString,
powerSupplyStatus AdicPowerSupplyStatus,
powerSupplyPowerConsumption INTEGER
}
powerSupplyIndex OBJECT-TYPE
SYNTAX INTEGER (0..1024)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Index of this power supply within the
component specified by componentId."
::= { powerSupplyEntry 1 }
powerSupplyName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Display name of this power supply."
::= { powerSupplyEntry 2 }
powerSupplyWattage OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Maximum power output of this power supply.
Units are in Watts."
::= { powerSupplyEntry 3 }
powerSupplyType OBJECT-TYPE
SYNTAX AdicVoltageType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Power supply type, AC or DC."
::= { powerSupplyEntry 4 }
powerSupplyREDId OBJECT-TYPE
SYNTAX AdicREDIdentifier
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Runtime Error Detection identifier for this
power supply."
::= { powerSupplyEntry 5 }
powerSupplyRatedVoltage OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Rated output voltage of this power supply. Units are in in millivolts."
::= { powerSupplyEntry 6 }
powerSupplyLocation OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Power supply location in the library."
::= { powerSupplyEntry 7 }
powerSupplyStatus OBJECT-TYPE
SYNTAX AdicPowerSupplyStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Power Supply operational status."
::= { powerSupplyEntry 8 }
powerSupplyPowerConsumption OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Power consumption of this power supply. Units are in watts."
::= { powerSupplyEntry 9 }
-- The Voltage Sensor table contains one entry for every voltage sensor in
-- the library. A power supply may have multiple voltage sensors in various
-- locations
voltageSensorTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoltageSensorEntry
ACCESS not-accessible
STATUS optional
DESCRIPTION
"This table provides voltage sensor information."
::= { powerAndCooling 20 }
voltageSensorEntry OBJECT-TYPE
SYNTAX VoltageSensorEntry
ACCESS not-accessible
STATUS optional
DESCRIPTION
"Each entry contains the information for a
specific voltage sensor."
INDEX { componentId, powerSupplyIndex, voltageSensorIndex }
::= { voltageSensorTable 1 }
VoltageSensorEntry ::=
SEQUENCE {
voltageSensorIndex INTEGER,
voltageSensorName DisplayString,
voltageSensorStatus AdicSensorStatus,
voltageSensorMillivolts INTEGER,
voltageSensorType AdicVoltageType,
voltageSensorNominalLo INTEGER,
voltageSensorNominalHi INTEGER,
voltageSensorWarningLo INTEGER,
voltageSensorWarningHi INTEGER,
voltageSensorLocation DisplayString,
voltageSensorREDId AdicREDIdentifier
}
voltageSensorIndex OBJECT-TYPE
SYNTAX INTEGER (0..1024)
ACCESS read-only
STATUS optional
DESCRIPTION
"Index of this voltage sensor within the
component specified by componentId."
::= { voltageSensorEntry 1 }
voltageSensorName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"Display name of this voltage sensor."
::= { voltageSensorEntry 2 }
voltageSensorStatus OBJECT-TYPE
SYNTAX AdicSensorStatus
ACCESS read-only
STATUS optional
DESCRIPTION
"Voltage sensor state; - nominal, warning or alarm."
::= { voltageSensorEntry 3 }
voltageSensorMillivolts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Voltage sensor voltage. units are in millivolts."
::= { voltageSensorEntry 4 }
voltageSensorType OBJECT-TYPE
SYNTAX AdicVoltageType
ACCESS read-only
STATUS optional
DESCRIPTION
"Voltage sensor type; - DC or AC."
::= { voltageSensorEntry 5 }
voltageSensorNominalLo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Lower voltage limit of the nominal state
for this voltage sensor. Units are in millivolts."
::= { voltageSensorEntry 6 }
voltageSensorNominalHi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Upper voltage limit of the nominal state
for this voltage sensor. Units are in millivolts."
::= { voltageSensorEntry 7 }
voltageSensorWarningLo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Lower voltage limit of the warning state
for this voltage sensor. Units are in millivolts.
If the voltage falls below this limit, the
sensor enters the alarm state."
::= { voltageSensorEntry 8 }
voltageSensorWarningHi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Upper voltage limit of the warning state
for this voltage sensor. Units are in millivolts.
If the voltage rises above this limit, the
sensor enters the alarm state."
::= { voltageSensorEntry 9 }
voltageSensorLocation OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"Physical location of the voltage sensor."
::= { voltageSensorEntry 10 }
voltageSensorREDId OBJECT-TYPE
SYNTAX AdicREDIdentifier
ACCESS read-only
STATUS optional
DESCRIPTION
"Runtime Error Detection identifier for this
voltage sensor."
::= { voltageSensorEntry 11 }
-- The Temperature Sensor table contains one entry for each temperature
-- sensor in the library
temperatureSensorTable OBJECT-TYPE
SYNTAX SEQUENCE OF TemperatureSensorEntry
ACCESS not-accessible
STATUS optional
DESCRIPTION
"This table provides temperature sensor information"
::= { powerAndCooling 30 }
temperatureSensorEntry OBJECT-TYPE
SYNTAX TemperatureSensorEntry
ACCESS not-accessible
STATUS optional
DESCRIPTION
"Each entry contains the information for a
specific sensor of a specifc component id."
INDEX { componentId, temperatureSensorIndex }
::= { temperatureSensorTable 1 }
TemperatureSensorEntry ::=
SEQUENCE {
temperatureSensorIndex INTEGER,
temperatureSensorName DisplayString,
temperatureSensorStatus AdicSensorStatus,
temperatureSensorDegreesCelsius INTEGER,
temperatureSensorNominalLo INTEGER,
temperatureSensorNominalHi INTEGER,
temperatureSensorWarningLo INTEGER,
temperatureSensorWarningHi INTEGER,
temperatureSensorLocation DisplayString,
temperatureSensorREDId AdicREDIdentifier
}
temperatureSensorIndex OBJECT-TYPE
SYNTAX INTEGER (0..1024)
ACCESS read-only
STATUS optional
DESCRIPTION
"Index of this temperature sensor within the
component specified by componentId."
::= { temperatureSensorEntry 1 }
temperatureSensorName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"Display name of this temperature sensor."
::= { temperatureSensorEntry 2 }
temperatureSensorStatus OBJECT-TYPE
SYNTAX AdicSensorStatus
ACCESS read-only
STATUS optional
DESCRIPTION
"Current state of the temperature sensor; - Nominal, warning or alarm."
::= { temperatureSensorEntry 3 }
temperatureSensorDegreesCelsius OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The temperature in degrees Celsius for this
temperature sensor."
::= { temperatureSensorEntry 4 }
temperatureSensorNominalLo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Lower temperature limit of the nominal state
for this temperature sensor. Units are in degrees Celsius."
::= { temperatureSensorEntry 5 }
temperatureSensorNominalHi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Upper temperature limit of the nominal state
for this temperature sensor. Units are in degrees Celsius."
::= { temperatureSensorEntry 6 }
temperatureSensorWarningLo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Lower temperature limit of the warning state
for this temperature sensor. Units are in degrees Celsius.
If the temperature falls below this limit,
the sensor enters the alarm state."
::= { temperatureSensorEntry 7 }
temperatureSensorWarningHi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Upper temperature limit of the warning state
for this temperature sensor. Units are in degrees Celsius.
If the temperature rises above this
limit, the sensor enters the alarm state."
::= { temperatureSensorEntry 8 }
temperatureSensorLocation OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"Physical location of this temperature sensor."
::= { temperatureSensorEntry 9 }
temperatureSensorREDId OBJECT-TYPE
SYNTAX AdicREDIdentifier
ACCESS read-only
STATUS optional
DESCRIPTION
"Runtime Error Detection identifier for this
temperature sensor."
::= { temperatureSensorEntry 10 }
-- The Cooling Fan table contains one entry for each temperature
-- sensor in the library
coolingFanTable OBJECT-TYPE
SYNTAX SEQUENCE OF CoolingFanEntry
ACCESS not-accessible
STATUS optional
DESCRIPTION
"This table provides library (not drive) cooling fan information."
::= { powerAndCooling 40 }
coolingFanEntry OBJECT-TYPE
SYNTAX CoolingFanEntry
ACCESS not-accessible
STATUS optional
DESCRIPTION
"Each entry contains the information for a
specific cooling fan."
INDEX { componentId, coolingFanIndex }
::= { coolingFanTable 1 }
CoolingFanEntry ::=
SEQUENCE {
coolingFanIndex INTEGER,
coolingFanName DisplayString,
coolingFanStatus AdicSensorStatus,
coolingFanRPM INTEGER,
coolingFanNominalLo INTEGER,
coolingFanNominalHi INTEGER,
coolingFanWarningLo INTEGER,
coolingFanWarningHi INTEGER,
coolingFanLocation DisplayString,
coolingFanREDId AdicREDIdentifier
}
coolingFanIndex OBJECT-TYPE
SYNTAX INTEGER (0..1024)
ACCESS read-only
STATUS optional
DESCRIPTION
"Index of this cooling fan within the
component specified by componentId."
::= { coolingFanEntry 1 }
coolingFanName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"Display name of this cooling fan."
::= { coolingFanEntry 2 }
coolingFanStatus OBJECT-TYPE
SYNTAX AdicSensorStatus
ACCESS read-only
STATUS optional
DESCRIPTION
"Cooling fan state; - nominal, warning or alarm."
::= { coolingFanEntry 3 }
coolingFanRPM OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"The fan speed in revolutions per minute."
::= { coolingFanEntry 4 }
coolingFanNominalLo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Lower fan speed limit of the nominal state
for this fan. Units are in RPM."
::= { coolingFanEntry 5 }
coolingFanNominalHi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Upper fan speed limit of the nominal state
for this fan. Units are in RPM."
::= { coolingFanEntry 6 }
coolingFanWarningLo OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Lower fan speed limit of the warning state
for this fan. Units are in RPM. If the speed
falls below this limit, the fan enters the
alarm state."
::= { coolingFanEntry 7 }
coolingFanWarningHi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION
"Upper fan speed limit of the warning state
for this fan. Units are in RPM. If the speed
rises above this limit, the fan enters the
alarm state."
::= { coolingFanEntry 8 }
coolingFanLocation OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS optional
DESCRIPTION
"Physical location of this fan."
::= { coolingFanEntry 9 }
coolingFanREDId OBJECT-TYPE
SYNTAX AdicREDIdentifier
ACCESS read-only
STATUS optional
DESCRIPTION
"Runtime Error Detection identifier for this fan."
::= { coolingFanEntry 10 }
-- **********************************************************
-- * *
-- * Notification Group *
-- * *
-- * Trap-related object definitions. *
-- * *
-- **********************************************************
--
-- The Trap Header Table
-- Defines common objects used in trap payloads
-- These objects exist only for the purpose of
-- describing trap payloads according to the
-- RFC 1215 TRAP-TYPE con struct. The table
-- may appear empty when traversed with GET or
-- GET-NEXT
trapPayloadTable OBJECT-TYPE
SYNTAX SEQUENCE OF TrapPayloadEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Defines objects common to all trap payloads."
::= { notification 10 }
trapPayloadEntry OBJECT-TYPE
SYNTAX TrapPayloadEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry contains the information for a
specific cooling fan."
INDEX { trapSequenceNumber }
::= { trapPayloadTable 1 }
TrapPayloadEntry ::=
SEQUENCE {
trapSequenceNumber INTEGER,
trapSeverity AdicTrapSeverity,
trapSummaryText DisplayString,
trapIntendedUsage INTEGER,
trapInstance INTEGER,
trapInstanceValue INTEGER
}
trapSequenceNumber OBJECT-TYPE
SYNTAX INTEGER (0 .. 65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The incrementing trap notification sequence number associated with this trap."
::= { trapPayloadEntry 1 }
trapSeverity OBJECT-TYPE
SYNTAX AdicTrapSeverity
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The TRAP notification severity."
::= { trapPayloadEntry 2 }
trapSummaryText OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The TRAP information summary."
::= { trapPayloadEntry 3 }
trapIntendedUsage OBJECT-TYPE
SYNTAX INTEGER { public(1), triggerRefresh(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this qualifier aids the
management application in determining
how to respond to the trap. If the
value is public(1), the information is
intended to be propagated to external
observers, such as sending email. If
the value is triggerRefresh(2), the
information is intended to update the
management application's data model,
but not necessarily propagated to external
observers."
::= { trapPayloadEntry 4 }
trapInstance OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The specifc TRAP instance for this TRAP."
::= { trapPayloadEntry 5 }
trapInstanceValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A management application specifc TRAP instance value
to further TRAP response processing."
::= { trapPayloadEntry 6 }
--
-- Intelligent Storage MIB Trap Definitions
-- (Additional ones definbed in ADIC Managment MIB)
--
-- Group traps according to trap "specific" number as follows:
--
-- 1 - 99 Power and Cooling Traps
-- 100 - 199 Physical Library Traps
-- 200 - 299 Logical Library Traps
-- 300 - 399 Connectivity Traps
-- 400 - 499 RAS
-- 500 - 599 System Level Traps
--
--
-- Note: Not all TRAPs are reported to an external receiver
-- and used internally by the library only.
-- THE VOLTAGE SENSOR STATUS CHANGE TRAP HAS BEEN
-- SUPERCEDED BY THE RAS POWER STATUS GROUP TRAP
--
-- voltageSensorStatusChange TRAP-TYPE
-- ENTERPRISE intelligent
-- VARIABLES
-- {
-- componentId,
-- trapSequenceNumber,
-- trapSeverity,
-- trapSummaryText,
-- powerSupplyIndex,
-- voltageSensorIndex,
-- voltageSensorStatus
-- }
-- DESCRIPTION
-- ""
-- ::= 1
-- THE TEMPERATURE SENSOR STATUS CHANGE TRAP HAS BEEN
-- SUPERCEDED BY THE RAS COOLING STATUS GROUP TRAP
--
-- temperatureSensorStatusChange TRAP-TYPE
-- ENTERPRISE intelligent
-- VARIABLES
-- {
-- componentId,
-- trapSequenceNumber,
-- trapSeverity,
-- trapSummaryText,
-- temperatureSensorIndex,
-- temperatureSensorStatus
-- }
-- DESCRIPTION
-- ""
-- ::= 2
-- THE COOLING FAN STATUS CHANGE TRAP HAS BEEN
-- SUPERCEDED BY THE RAS COOLING STATUS GROUP TRAP
--
-- coolingFanStatusChange TRAP-TYPE
-- ENTERPRISE intelligent
-- VARIABLES
-- {
-- componentId,
-- trapSequenceNumber,
-- trapSeverity,
-- trapSummaryText,
-- coolingFanIndex,
-- coolingFanStatus
-- }
-- DESCRIPTION
-- ""
-- ::= 3
-- TRAP 500 - external TRAP
startupSequenceComplete TRAP-TYPE
ENTERPRISE intelligent
VARIABLES
{
componentId,
trapSummaryText
}
DESCRIPTION
"The physical library completed a library initialization sequence:
componentId - identifies reporting controller
trapSummaryText - identifies completion of library initialization sequence
"
::= 500
-- TRAP 501 - external TRAP
shutdownSequenceInitiated TRAP-TYPE
ENTERPRISE intelligent
VARIABLES
{
componentId,
trapSummaryText
}
DESCRIPTION
"The physical library initiated a shutdown operation:
componentId - identifies reporting controller
trapSummaryText - identifies library shutdown operation
"
::= 501
-- TRAP 502 - internal TRAP only
componentAdded TRAP-TYPE
ENTERPRISE intelligent
VARIABLES
{
componentId, -- ID of new component added (i.e. blade)
componentType
}
DESCRIPTION
"The component indicated by the value
of componentId has been added to the
library."
::= 502
-- TRAP 503 - internal TRAP only
componentRemoved TRAP-TYPE
ENTERPRISE intelligent
VARIABLES
{
componentId, -- ID of component removed (i.e. blade)
componentType
}
DESCRIPTION
"The component indicated by the value
of componentId has been removed from the
library."
::= 503
-- TRAP 504 - internal TRAP only
productLibraryClassChange TRAP-TYPE
ENTERPRISE intelligent
VARIABLES
{
productLibraryClass, -- Before change
productLibraryClass -- After change
}
DESCRIPTION
"The product library class has changed.
This occurs when connectivity hardware
is added or removed. The payload contains
the productLibraryClass before and after
the change."
::= 504
END