{ "os": { "discovery": { "devices": [ { "sysName": "", "sysObjectID": ".1.3.6.1.4.1.11863.5.33", "sysDescr": "JetStream 24-Port Gigabit L2 Managed Switch with 4 SFP Slots", "sysContact": "", "version": "3.0.3 Build 20181101 Rel.42543(s)", "hardware": "T2600G-28TS 3.0", "features": null, "location": "", "os": "jetstream", "type": "network", "serial": "217B851000014", "icon": "tplink.svg" } ] }, "poller": "matches discovery" }, "mempools": { "discovery": { "mempools": [ { "mempool_index": "1", "entPhysicalIndex": null, "mempool_type": "jetstream", "mempool_class": "system", "mempool_precision": 1, "mempool_descr": "Memory #1", "mempool_perc": 68, "mempool_perc_oid": ".1.3.6.1.4.1.11863.6.4.1.2.1.1.2.1", "mempool_used": 68, "mempool_used_oid": null, "mempool_free": 32, "mempool_free_oid": null, "mempool_total": 100, "mempool_total_oid": null, "mempool_largestfree": null, "mempool_lowestfree": null, "mempool_deleted": 0, "mempool_perc_warn": 90 } ] }, "poller": "matches discovery" }, "processors": { "discovery": { "processors": [ { "entPhysicalIndex": 0, "hrDeviceIndex": 0, "processor_oid": ".1.3.6.1.4.1.11863.6.4.1.1.1.1.2.1", "processor_index": "1", "processor_type": "jetstream", "processor_usage": 27, "processor_descr": "Proc #1", "processor_precision": 1, "processor_perc_warn": 75 } ] }, "poller": "matches discovery" }, "sensors": { "discovery": { "sensors": [ { "sensor_deleted": 0, "sensor_class": "current", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.4.49177", "sensor_index": "ddmStatusBiasCurrent.49177", "sensor_type": "jetstream", "sensor_descr": "DDM Bias Current 1/0/25", "group": "SFPs", "sensor_divisor": 1000, "sensor_multiplier": 1, "sensor_current": 0.009568, "sensor_limit": 0.015, "sensor_limit_warn": 0.013, "sensor_limit_low": 0.001, "sensor_limit_low_warn": 0.002, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "49177", "entPhysicalIndex_measured": "ports", "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": null }, { "sensor_deleted": 0, "sensor_class": "current", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.4.49178", "sensor_index": "ddmStatusBiasCurrent.49178", "sensor_type": "jetstream", "sensor_descr": "DDM Bias Current 1/0/26", "group": "SFPs", "sensor_divisor": 1000, "sensor_multiplier": 1, "sensor_current": 0.009176, "sensor_limit": 0.015, "sensor_limit_warn": 0.013, "sensor_limit_low": 0.001, "sensor_limit_low_warn": 0.002, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "49178", "entPhysicalIndex_measured": "ports", "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.6.49177", "sensor_index": "ddmStatusRxPow.49177", "sensor_type": "jetstream", "sensor_descr": "DDM RX Power 1/0/25", "group": "SFPs", "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": -5.9998036493484, "sensor_limit": 0, "sensor_limit_warn": -1.0001543745061, "sensor_limit_low": -28.538719643218, "sensor_limit_low_warn": -26.98970004336, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "49177", "entPhysicalIndex_measured": "ports", "sensor_prev": null, "user_func": "mw_to_dbm", "rrd_type": "GAUGE", "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.6.49178", "sensor_index": "ddmStatusRxPow.49178", "sensor_type": "jetstream", "sensor_descr": "DDM RX Power 1/0/26", "group": "SFPs", "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": -5.9998036493484, "sensor_limit": 0, "sensor_limit_warn": -1.0001543745061, "sensor_limit_low": -28.538719643218, "sensor_limit_low_warn": -26.98970004336, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "49178", "entPhysicalIndex_measured": "ports", "sensor_prev": null, "user_func": "mw_to_dbm", "rrd_type": "GAUGE", "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.5.49177", "sensor_index": "ddmStatusTxPow.49177", "sensor_type": "jetstream", "sensor_descr": "DDM TX Power 1/0/25", "group": "SFPs", "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": -4.0011692792631, "sensor_limit": 0, "sensor_limit_warn": -1.0001543745061, "sensor_limit_low": -11.999706407559, "sensor_limit_low_warn": -11.001794975729, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "49177", "entPhysicalIndex_measured": "ports", "sensor_prev": null, "user_func": "mw_to_dbm", "rrd_type": "GAUGE", "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.5.49178", "sensor_index": "ddmStatusTxPow.49178", "sensor_type": "jetstream", "sensor_descr": "DDM TX Power 1/0/26", "group": "SFPs", "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": -3.9902710431325, "sensor_limit": 0, "sensor_limit_warn": -1.0001543745061, "sensor_limit_low": -11.999706407559, "sensor_limit_low_warn": -11.001794975729, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "49178", "entPhysicalIndex_measured": "ports", "sensor_prev": null, "user_func": "mw_to_dbm", "rrd_type": "GAUGE", "state_name": null }, { "sensor_deleted": 0, "sensor_class": "state", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.7.49177", "sensor_index": "49177", "sensor_type": "ddmStatusDataReady", "sensor_descr": "DDM Data Ready 1/0/25", "group": "SFPs", "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": 0, "sensor_limit": null, "sensor_limit_warn": null, "sensor_limit_low": null, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "49177", "entPhysicalIndex_measured": "ports", "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": "ddmStatusDataReady" }, { "sensor_deleted": 0, "sensor_class": "state", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.7.49178", "sensor_index": "49178", "sensor_type": "ddmStatusDataReady", "sensor_descr": "DDM Data Ready 1/0/26", "group": "SFPs", "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": 0, "sensor_limit": null, "sensor_limit_warn": null, "sensor_limit_low": null, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "49178", "entPhysicalIndex_measured": "ports", "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": "ddmStatusDataReady" }, { "sensor_deleted": 0, "sensor_class": "state", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.8.49177", "sensor_index": "49177", "sensor_type": "ddmStatusLossSignal", "sensor_descr": "DDM Loss of Signal 1/0/25", "group": "SFPs", "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": 0, "sensor_limit": null, "sensor_limit_warn": null, "sensor_limit_low": null, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "49177", "entPhysicalIndex_measured": "ports", "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": "ddmStatusLossSignal" }, { "sensor_deleted": 0, "sensor_class": "state", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.8.49178", "sensor_index": "49178", "sensor_type": "ddmStatusLossSignal", "sensor_descr": "DDM Loss of Signal 1/0/26", "group": "SFPs", "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": 0, "sensor_limit": null, "sensor_limit_warn": null, "sensor_limit_low": null, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "49178", "entPhysicalIndex_measured": "ports", "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": "ddmStatusLossSignal" }, { "sensor_deleted": 0, "sensor_class": "state", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.9.49177", "sensor_index": "49177", "sensor_type": "ddmStatusTxFault", "sensor_descr": "DDM TX Fault 1/0/25", "group": "SFPs", "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": 0, "sensor_limit": null, "sensor_limit_warn": null, "sensor_limit_low": null, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "49177", "entPhysicalIndex_measured": "ports", "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": "ddmStatusTxFault" }, { "sensor_deleted": 0, "sensor_class": "state", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.9.49178", "sensor_index": "49178", "sensor_type": "ddmStatusTxFault", "sensor_descr": "DDM TX Fault 1/0/26", "group": "SFPs", "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": 0, "sensor_limit": null, "sensor_limit_warn": null, "sensor_limit_low": null, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "49178", "entPhysicalIndex_measured": "ports", "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": "ddmStatusTxFault" }, { "sensor_deleted": 0, "sensor_class": "temperature", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.2.49177", "sensor_index": "ddmStatusTemperature.49177", "sensor_type": "jetstream", "sensor_descr": "DDM Temperature 1/0/25", "group": "SFPs", "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": 50, "sensor_limit": 80, "sensor_limit_warn": 75, "sensor_limit_low": -10, "sensor_limit_low_warn": -5, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "49177", "entPhysicalIndex_measured": "ports", "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": null }, { "sensor_deleted": 0, "sensor_class": "temperature", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.2.49178", "sensor_index": "ddmStatusTemperature.49178", "sensor_type": "jetstream", "sensor_descr": "DDM Temperature 1/0/26", "group": "SFPs", "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": 52, "sensor_limit": 80, "sensor_limit_warn": 75, "sensor_limit_low": -10, "sensor_limit_low_warn": -5, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "49178", "entPhysicalIndex_measured": "ports", "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.3.49177", "sensor_index": "ddmStatusVoltage.49177", "sensor_type": "jetstream", "sensor_descr": "DDM Voltage 1/0/25", "group": "SFPs", "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": 3.4162, "sensor_limit": 3.6, "sensor_limit_warn": 3.5, "sensor_limit_low": 3, "sensor_limit_low_warn": 3.1, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "49177", "entPhysicalIndex_measured": "ports", "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.3.49178", "sensor_index": "ddmStatusVoltage.49178", "sensor_type": "jetstream", "sensor_descr": "DDM Voltage 1/0/26", "group": "SFPs", "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": 3.385, "sensor_limit": 3.6, "sensor_limit_warn": 3.5, "sensor_limit_low": 3, "sensor_limit_low_warn": 3.1, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "49178", "entPhysicalIndex_measured": "ports", "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": null } ], "state_indexes": [ { "state_name": "ddmStatusDataReady", "state_descr": "False", "state_draw_graph": 0, "state_value": 0, "state_generic_value": 0 }, { "state_name": "ddmStatusDataReady", "state_descr": "True", "state_draw_graph": 1, "state_value": 1, "state_generic_value": 2 }, { "state_name": "ddmStatusDataReady", "state_descr": "N/A", "state_draw_graph": 2, "state_value": 2, "state_generic_value": 2 }, { "state_name": "ddmStatusLossSignal", "state_descr": "False", "state_draw_graph": 0, "state_value": 0, "state_generic_value": 0 }, { "state_name": "ddmStatusLossSignal", "state_descr": "True", "state_draw_graph": 1, "state_value": 1, "state_generic_value": 2 }, { "state_name": "ddmStatusLossSignal", "state_descr": "N/A", "state_draw_graph": 2, "state_value": 2, "state_generic_value": 2 }, { "state_name": "ddmStatusTxFault", "state_descr": "False", "state_draw_graph": 0, "state_value": 0, "state_generic_value": 0 }, { "state_name": "ddmStatusTxFault", "state_descr": "True", "state_draw_graph": 1, "state_value": 1, "state_generic_value": 2 }, { "state_name": "ddmStatusTxFault", "state_descr": "N/A", "state_draw_graph": 2, "state_value": 2, "state_generic_value": 2 } ] }, "poller": { "sensors": [ { "sensor_deleted": 0, "sensor_class": "current", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.4.49177", "sensor_index": "ddmStatusBiasCurrent.49177", "sensor_type": "jetstream", "sensor_descr": "DDM Bias Current 1/0/25", "group": "SFPs", "sensor_divisor": 1000, "sensor_multiplier": 1, "sensor_current": 0.009568, "sensor_limit": 0.015, "sensor_limit_warn": 0.013, "sensor_limit_low": 0.001, "sensor_limit_low_warn": 0.002, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "49177", "entPhysicalIndex_measured": "ports", "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": null }, { "sensor_deleted": 0, "sensor_class": "current", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.4.49178", "sensor_index": "ddmStatusBiasCurrent.49178", "sensor_type": "jetstream", "sensor_descr": "DDM Bias Current 1/0/26", "group": "SFPs", "sensor_divisor": 1000, "sensor_multiplier": 1, "sensor_current": 0.009176, "sensor_limit": 0.015, "sensor_limit_warn": 0.013, "sensor_limit_low": 0.001, "sensor_limit_low_warn": 0.002, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "49178", "entPhysicalIndex_measured": "ports", "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.6.49177", "sensor_index": "ddmStatusRxPow.49177", "sensor_type": "jetstream", "sensor_descr": "DDM RX Power 1/0/25", "group": "SFPs", "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": -5.9998036493484, "sensor_limit": 0, "sensor_limit_warn": -1.0001543745061, "sensor_limit_low": -28.538719643218, "sensor_limit_low_warn": -26.98970004336, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "49177", "entPhysicalIndex_measured": "ports", "sensor_prev": -5.9998036493484, "user_func": "mw_to_dbm", "rrd_type": "GAUGE", "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.6.49178", "sensor_index": "ddmStatusRxPow.49178", "sensor_type": "jetstream", "sensor_descr": "DDM RX Power 1/0/26", "group": "SFPs", "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": -5.9998036493484, "sensor_limit": 0, "sensor_limit_warn": -1.0001543745061, "sensor_limit_low": -28.538719643218, "sensor_limit_low_warn": -26.98970004336, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "49178", "entPhysicalIndex_measured": "ports", "sensor_prev": -5.9998036493484, "user_func": "mw_to_dbm", "rrd_type": "GAUGE", "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.5.49177", "sensor_index": "ddmStatusTxPow.49177", "sensor_type": "jetstream", "sensor_descr": "DDM TX Power 1/0/25", "group": "SFPs", "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": -4.0011692792631, "sensor_limit": 0, "sensor_limit_warn": -1.0001543745061, "sensor_limit_low": -11.999706407559, "sensor_limit_low_warn": -11.001794975729, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "49177", "entPhysicalIndex_measured": "ports", "sensor_prev": -4.0011692792631, "user_func": "mw_to_dbm", "rrd_type": "GAUGE", "state_name": null }, { "sensor_deleted": 0, "sensor_class": "dbm", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.5.49178", "sensor_index": "ddmStatusTxPow.49178", "sensor_type": "jetstream", "sensor_descr": "DDM TX Power 1/0/26", "group": "SFPs", "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": -3.9902710431325, "sensor_limit": 0, "sensor_limit_warn": -1.0001543745061, "sensor_limit_low": -11.999706407559, "sensor_limit_low_warn": -11.001794975729, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "49178", "entPhysicalIndex_measured": "ports", "sensor_prev": -3.9902710431325, "user_func": "mw_to_dbm", "rrd_type": "GAUGE", "state_name": null }, { "sensor_deleted": 0, "sensor_class": "state", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.7.49177", "sensor_index": "49177", "sensor_type": "ddmStatusDataReady", "sensor_descr": "DDM Data Ready 1/0/25", "group": "SFPs", "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": 0, "sensor_limit": null, "sensor_limit_warn": null, "sensor_limit_low": null, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "49177", "entPhysicalIndex_measured": "ports", "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": "ddmStatusDataReady" }, { "sensor_deleted": 0, "sensor_class": "state", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.7.49178", "sensor_index": "49178", "sensor_type": "ddmStatusDataReady", "sensor_descr": "DDM Data Ready 1/0/26", "group": "SFPs", "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": 0, "sensor_limit": null, "sensor_limit_warn": null, "sensor_limit_low": null, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "49178", "entPhysicalIndex_measured": "ports", "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": "ddmStatusDataReady" }, { "sensor_deleted": 0, "sensor_class": "state", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.8.49177", "sensor_index": "49177", "sensor_type": "ddmStatusLossSignal", "sensor_descr": "DDM Loss of Signal 1/0/25", "group": "SFPs", "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": 0, "sensor_limit": null, "sensor_limit_warn": null, "sensor_limit_low": null, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "49177", "entPhysicalIndex_measured": "ports", "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": "ddmStatusLossSignal" }, { "sensor_deleted": 0, "sensor_class": "state", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.8.49178", "sensor_index": "49178", "sensor_type": "ddmStatusLossSignal", "sensor_descr": "DDM Loss of Signal 1/0/26", "group": "SFPs", "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": 0, "sensor_limit": null, "sensor_limit_warn": null, "sensor_limit_low": null, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "49178", "entPhysicalIndex_measured": "ports", "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": "ddmStatusLossSignal" }, { "sensor_deleted": 0, "sensor_class": "state", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.9.49177", "sensor_index": "49177", "sensor_type": "ddmStatusTxFault", "sensor_descr": "DDM TX Fault 1/0/25", "group": "SFPs", "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": 0, "sensor_limit": null, "sensor_limit_warn": null, "sensor_limit_low": null, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "49177", "entPhysicalIndex_measured": "ports", "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": "ddmStatusTxFault" }, { "sensor_deleted": 0, "sensor_class": "state", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.9.49178", "sensor_index": "49178", "sensor_type": "ddmStatusTxFault", "sensor_descr": "DDM TX Fault 1/0/26", "group": "SFPs", "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": 0, "sensor_limit": null, "sensor_limit_warn": null, "sensor_limit_low": null, "sensor_limit_low_warn": null, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "49178", "entPhysicalIndex_measured": "ports", "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": "ddmStatusTxFault" }, { "sensor_deleted": 0, "sensor_class": "temperature", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.2.49177", "sensor_index": "ddmStatusTemperature.49177", "sensor_type": "jetstream", "sensor_descr": "DDM Temperature 1/0/25", "group": "SFPs", "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": 50, "sensor_limit": 80, "sensor_limit_warn": 75, "sensor_limit_low": -10, "sensor_limit_low_warn": -5, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "49177", "entPhysicalIndex_measured": "ports", "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": null }, { "sensor_deleted": 0, "sensor_class": "temperature", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.2.49178", "sensor_index": "ddmStatusTemperature.49178", "sensor_type": "jetstream", "sensor_descr": "DDM Temperature 1/0/26", "group": "SFPs", "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": 52, "sensor_limit": 80, "sensor_limit_warn": 75, "sensor_limit_low": -10, "sensor_limit_low_warn": -5, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "49178", "entPhysicalIndex_measured": "ports", "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.3.49177", "sensor_index": "ddmStatusVoltage.49177", "sensor_type": "jetstream", "sensor_descr": "DDM Voltage 1/0/25", "group": "SFPs", "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": 3.4162, "sensor_limit": 3.6, "sensor_limit_warn": 3.5, "sensor_limit_low": 3, "sensor_limit_low_warn": 3.1, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "49177", "entPhysicalIndex_measured": "ports", "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": null }, { "sensor_deleted": 0, "sensor_class": "voltage", "poller_type": "snmp", "sensor_oid": ".1.3.6.1.4.1.11863.6.96.1.7.1.1.3.49178", "sensor_index": "ddmStatusVoltage.49178", "sensor_type": "jetstream", "sensor_descr": "DDM Voltage 1/0/26", "group": "SFPs", "sensor_divisor": 1, "sensor_multiplier": 1, "sensor_current": 3.385, "sensor_limit": 3.6, "sensor_limit_warn": 3.5, "sensor_limit_low": 3, "sensor_limit_low_warn": 3.1, "sensor_alert": 1, "sensor_custom": "No", "entPhysicalIndex": "49178", "entPhysicalIndex_measured": "ports", "sensor_prev": null, "user_func": null, "rrd_type": "GAUGE", "state_name": null } ], "state_indexes": [ { "state_name": "ddmStatusDataReady", "state_descr": "False", "state_draw_graph": 0, "state_value": 0, "state_generic_value": 0 }, { "state_name": "ddmStatusDataReady", "state_descr": "True", "state_draw_graph": 1, "state_value": 1, "state_generic_value": 2 }, { "state_name": "ddmStatusDataReady", "state_descr": "N/A", "state_draw_graph": 2, "state_value": 2, "state_generic_value": 2 }, { "state_name": "ddmStatusLossSignal", "state_descr": "False", "state_draw_graph": 0, "state_value": 0, "state_generic_value": 0 }, { "state_name": "ddmStatusLossSignal", "state_descr": "True", "state_draw_graph": 1, "state_value": 1, "state_generic_value": 2 }, { "state_name": "ddmStatusLossSignal", "state_descr": "N/A", "state_draw_graph": 2, "state_value": 2, "state_generic_value": 2 }, { "state_name": "ddmStatusTxFault", "state_descr": "False", "state_draw_graph": 0, "state_value": 0, "state_generic_value": 0 }, { "state_name": "ddmStatusTxFault", "state_descr": "True", "state_draw_graph": 1, "state_value": 1, "state_generic_value": 2 }, { "state_name": "ddmStatusTxFault", "state_descr": "N/A", "state_draw_graph": 2, "state_value": 2, "state_generic_value": 2 } ] } } }