-- -- Dell Remote Access Controller (RAC) and Chassis Management Controller (CMC) -- Management Information Base -- -- This MIB is the legacy iDRAC MIB. Changes are no longer made to this MIB -- for iDRACs. iDRACs don't support all of the objects and traps defined -- in this MIB. There is a new and more extensive iDRAC MIB available for -- newer iDRACs (iDRAC7 and newer). -- -- This MIB is also the CMC MIB. Changes are made to this MIB only for CMCs now. -- -- Copyright (c) 2014 Dell Inc. -- -- Last Changed Revision: 16 -- Last Changed Date: 2014-07-14 12:25:06 -0500 (Mon, 14 Jul 2014) -- Text Last Updated: 2014-07-14 12:25:06 -0500 (Mon, 14 Jul 2014) -- DELL-RAC-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises, TimeTicks FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215 DisplayString FROM RFC1213-MIB; -- text convention ------------------------------------------------------------------------ ------------------------------------------------------------------------------- -- This data type is used to model textual information taken -- from the NVT ASCII character set. By convention, objects -- with this syntax are declared as having -- SIZE (0..1023) ------------------------------------------------------------------------------- DellString ::= DisplayString (SIZE (0..1023)) DellRacType ::= INTEGER { other(1), -- the DRAC type is not one of the following unknown(2), -- the DRAC type is unknown dracIII(3), -- Drac III era(4), -- ERA drac4(5), -- Drac 4 drac5(6), -- Drac 5 drac5MC(7), -- Drac 5/MC cmc(8), -- CMC idrac(9), -- iDRAC idrac7monolithic(16), -- iDRAC7 Monolithic idrac7modular(17), -- iDRAC7 Modular vrtxCMC(18), -- VRTX CMC fx2CMC(19), -- FX2 Family CMC idrac8monolithic(32), -- iDRAC8 Monolithic idrac8modular(33) -- iDRAC8 Modular } DellStatus ::= INTEGER { other(1), -- the status of the object is not one of the following: unknown(2), -- the status of the object is unknown -- (not known or monitored) ok(3), -- the status of the object is ok nonCritical(4), -- the status of the object is warning, non-critical critical(5), -- the status of the object is critical (failure) nonRecoverable(6) -- the status of the object is non-recoverable (dead) } ------------------------------------------------------------------------------- -- DellPowerReading is a string representation of a floating point value, -- having exactly 3 digits of precision, and a maximum of 31 characters. -- -- DellChassisPowerIndexRange defines the possible chassis power instances -- in this MIB. -- -- DellCMCPSUIndexRange defines the possible CMC Power Supply Unit (PSU) -- instances, per chassis power instance, in this MIB. -- -- DellCMCPSUCapable is an enumeration of PSU presence and/or monitoring -- capabilities. -- -- DellTemperatureReading is an integer value, expressed in degrees Celsius. ------------------------------------------------------------------------------- DellPowerReading ::= DisplayString (SIZE (0..32)) DellCMCPowerIndexRange ::= INTEGER (1..1) DellCMCPSUIndexRange ::= INTEGER (1..6) DellCMCPSUCapable ::= INTEGER { absent(1), -- power supply is not present none(2), -- no power monitoring abilities basic(3) -- basic power monitoring abilities } DellTemperatureReading ::= INTEGER ------------------------------------------------------------------------------- -- DellTimestamp is defined in the displayable format: -- -- yyyymmddHHMMSS.uuuuuuDooo -- -- where yyyy is the year, mm is the month number, dd is the day of the month, -- HHMMSS are the hours, minutes and seconds, respectively, uuuuuu is the -- number of microseconds, D is the UTC offset direction, and ooo is the -- offset from UTC, in minutes. -- -- Note: D is a plus (+) sign if east of UTC, and a minus (-) if west of UTC. -- -- For example, Wednesday, May 25, 1994, at 1:30:15 PM EDT -- would be represented as: 19940525133015.000000-300 ------------------------------------------------------------------------------- DellTimestamp ::= DisplayString (SIZE (26)) ------------------------------------------------------------------------------- -- DellCMCServerIndexRange defines the possible chassis server instances -- in this MIB. -- -- DellCMCServerCapable is an enumeration of server presence and/or monitoring -- capabilities. ------------------------------------------------------------------------------- DellCMCServerIndexRange ::= INTEGER (1..32) DellCMCServerCapable ::= INTEGER { absent(1), -- server is not present none(2), -- no server monitoring abilities basic(3), -- basic server monitoring abilities off(4) -- server is powered off } -- MIB Objects and Tables -------------------------------------------------------- dell OBJECT IDENTIFIER ::= { enterprises 674 } server3 OBJECT IDENTIFIER ::= { dell 10892 } drsOutofBandGroup OBJECT IDENTIFIER ::= { server3 2 } drsInformationGroup OBJECT IDENTIFIER ::= { drsOutofBandGroup 1 } drsProductInfoGroup OBJECT IDENTIFIER ::= { drsInformationGroup 1 } drsFirmwareGroup OBJECT IDENTIFIER ::= { drsInformationGroup 2 } drsStatusGroup OBJECT IDENTIFIER ::= { drsOutofBandGroup 2 } drsChassisStatusGroup OBJECT IDENTIFIER ::= { drsOutofBandGroup 3 } drsStatusNowGroup OBJECT IDENTIFIER ::= { drsChassisStatusGroup 1 } drsStatusPrevGroup OBJECT IDENTIFIER ::= { drsChassisStatusGroup 2 } drsStatusChangeGroup OBJECT IDENTIFIER ::= { drsChassisStatusGroup 3 } drsChassisPowerGroup OBJECT IDENTIFIER ::= { drsOutofBandGroup 4 } DrsCMCPowerTableEntry ::= SEQUENCE { drsChassisIndex DellCMCPowerIndexRange, drsPotentialPower DellPowerReading, drsIdlePower DellPowerReading, drsMaxPowerSpecification DellPowerReading, drsPowerSurplus DellPowerReading, drsKWhCumulative DellPowerReading, drsKWhCumulativeTime DellTimestamp, drsWattsPeakUsage DellPowerReading, drsWattsPeakTime DellTimestamp, drsWattsMinUsage DellPowerReading, drsWattsMinTime DellTimestamp, drsWattsResetTime DellTimestamp, drsWattsReading DellPowerReading, drsAmpsReading DellPowerReading } DrsCMCPSUTableEntry ::= SEQUENCE { drsPSUChassisIndex DellCMCPowerIndexRange, drsPSUIndex DellCMCPSUIndexRange, drsPSULocation DellString, drsPSUMonitoringCapable DellCMCPSUCapable, drsPSUVoltsReading DellPowerReading, drsPSUAmpsReading DellPowerReading, drsPSUWattsReading DellPowerReading } drsChassisServerGroup OBJECT IDENTIFIER ::= { drsOutofBandGroup 5 } DrsCMCServerTableEntry ::= SEQUENCE { drsServerIndex DellCMCServerIndexRange, drsServerMonitoringCapable DellCMCServerCapable, drsServerServiceTag DellString, drsServerSlotName DellString, drsServerSlotNumber DellString, drsServerNodeID DellString } drsCMCAlertGroup OBJECT IDENTIFIER ::= { drsOutofBandGroup 20 } drsChassisAlertVariables OBJECT IDENTIFIER ::= { drsCMCAlertGroup 10 } drsCMCAlert2Group OBJECT IDENTIFIER ::= { drsOutofBandGroup 21 } drsChassisAlert2Variables OBJECT IDENTIFIER ::= { drsCMCAlert2Group 10 } drsAlertGroup OBJECT IDENTIFIER ::= { drsOutofBandGroup 5000 } drsAlertVariables OBJECT IDENTIFIER ::= { drsAlertGroup 10 } -- Variables and Traps ------------------------------------------------------------------------ ------------------------------------------------------------------------------- -- group: product information ------------------------------------------------------------------------------- drsProductName OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "0001.0001.0001 This attribute defines the product name of a chassis management controller." ::= { drsProductInfoGroup 1 } drsProductShortName OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "0001.0001.0002 This attribute defines the short product name of a chassis management controller. " ::= { drsProductInfoGroup 2 } drsProductDescription OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "0001.0001.0003 This attribute defines the product description of a chassis management controller. " ::= { drsProductInfoGroup 3 } drsProductManufacturer OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "0001.0001.0004 This attribute defines the product manufacturer of a chassis management controller. " ::= { drsProductInfoGroup 4 } drsProductVersion OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "0001.0001.0005 This attribute defines the product version of a chassis management controller. " ::= { drsProductInfoGroup 5 } drsChassisServiceTag OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "0001.0001.0007 This attribute defines the Service Tag of the chassis. " ::= { drsProductInfoGroup 6 } drsProductURL OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "0001.0001.0006 This attribute defines the out-of-band UI URL of a chassis management controller. " ::= { drsProductInfoGroup 7 } drsProductChassisAssetTag OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "0001.0001.0008 This attribute defines the Asset Tag of the chassis. " ::= { drsProductInfoGroup 8 } drsProductChassisLocation OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "0001.0001.0009 This attribute defines the location of the chassis. " ::= { drsProductInfoGroup 9 } drsProductChassisName OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "0001.0001.0010 This attribute defines the name of the chassis. " ::= { drsProductInfoGroup 10 } drsSystemServiceTag OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "0001.0001.0011 This attribute defines the service tag of a system. " ::= { drsProductInfoGroup 11 } drsProductSystemAssetTag OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "0001.0001.0012 This attribute defines the asset tag of a system. " ::= { drsProductInfoGroup 12 } drsProductSystemSlot OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "0001.0001.0013 This attribute defines the slot number of a CMC. " ::= { drsProductInfoGroup 13 } drsProductType OBJECT-TYPE SYNTAX DellRacType ACCESS read-only STATUS mandatory DESCRIPTION "0001.0001.0014 This attribute defines type of a remote access card " ::= { drsProductInfoGroup 14 } drsProductChassisDataCenter OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "0001.0001.0015 This attribute defines the Data Center locator of the chassis. " ::= { drsProductInfoGroup 15 } drsProductChassisAisle OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "0001.0001.0016 This attribute defines the Aisle locator of the chassis. " ::= { drsProductInfoGroup 16 } drsProductChassisRack OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "0001.0001.0017 This attribute defines the Rack locator of the chassis. " ::= { drsProductInfoGroup 17 } drsProductChassisRackSlot OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "0001.0001.0018 This attribute defines the Rack Slot locator of the chassis. " ::= { drsProductInfoGroup 18 } drsProductChassisModel OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "0001.0001.0019 This attribute defines the Model of the chassis." ::= { drsProductInfoGroup 19 } drsProductChassisExpressServiceCode OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "0001.0001.0020 This attribute defines the Express Service Code of the chassis." ::= { drsProductInfoGroup 20 } drsProductChassisSystemID OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "0001.0001.0021 This attribute defines the System ID of the chassis." ::= { drsProductInfoGroup 21 } drsProductChassisSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "0001.0001.0022 This attribute defines the size of the chassis in rack units (U). A U is a standard unit of measure for the height of a rack or rack-mountable component." ::= { drsProductInfoGroup 22 } ------------------------------------------------------------------------------- -- group: firmware ------------------------------------------------------------------------------- drsFirmwareVersion OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "0001.0002.0001 This attribute defines the firmware version of chassis management controller 1." ::= { drsFirmwareGroup 1 } drsiKVMFirmwareVersion OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "0001.0002.0002 This attribute defines the firmware version of the iKVM. " ::= { drsFirmwareGroup 2 } drsFirmwareVersion2 OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "0001.0002.0003 This attribute defines the firmware version of chassis management controller 2." ::= { drsFirmwareGroup 3 } ------------------------------------------------------------------------------- -- group: chassis status ------------------------------------------------------------------------------- drsGlobalSystemStatus OBJECT-TYPE SYNTAX DellStatus ACCESS read-only STATUS mandatory DESCRIPTION "0002.0001.0001 This attribute defines the overall chassis status being monitored by the chassis management card." ::= { drsStatusGroup 1 } drsGlobalCurrStatus OBJECT-TYPE SYNTAX DellStatus ACCESS read-only STATUS mandatory DESCRIPTION "0003.0001.0001 This attribute defines the overall chassis status being monitored by the chassis management card." ::= { drsStatusNowGroup 1 } drsIOMCurrStatus OBJECT-TYPE SYNTAX DellStatus ACCESS read-only STATUS mandatory DESCRIPTION "0003.0001.0002 This attribute defines the IOM subsystem status being monitored by the chassis management card." ::= { drsStatusNowGroup 2 } drsKVMCurrStatus OBJECT-TYPE SYNTAX DellStatus ACCESS read-only STATUS mandatory DESCRIPTION "0003.0001.0003 This attribute defines the iKVM subsystem health status being monitored by the chassis management card." ::= { drsStatusNowGroup 3 } drsRedCurrStatus OBJECT-TYPE SYNTAX DellStatus ACCESS read-only STATUS mandatory DESCRIPTION "0003.0001.0004 This attribute defines the Redundancy status being monitored by the chassis management card." ::= { drsStatusNowGroup 4 } drsPowerCurrStatus OBJECT-TYPE SYNTAX DellStatus ACCESS read-only STATUS mandatory DESCRIPTION "0003.0001.0005 This attribute defines the power subsystem health status being monitored by the chassis management card." ::= { drsStatusNowGroup 5 } drsFanCurrStatus OBJECT-TYPE SYNTAX DellStatus ACCESS read-only STATUS mandatory DESCRIPTION "0003.0001.0006 This attribute defines the Fan subsystem health status being monitored by the chassis management card." ::= { drsStatusNowGroup 6 } drsBladeCurrStatus OBJECT-TYPE SYNTAX DellStatus ACCESS read-only STATUS mandatory DESCRIPTION "0003.0001.0007 This attribute defines the Blade subsystem health status being monitored by the chassis management card." ::= { drsStatusNowGroup 7 } drsTempCurrStatus OBJECT-TYPE SYNTAX DellStatus ACCESS read-only STATUS mandatory DESCRIPTION "0003.0001.0008 This attribute defines the Temp Sensor subsystem health status being monitored by the chassis management card." ::= { drsStatusNowGroup 8 } drsCMCCurrStatus OBJECT-TYPE SYNTAX DellStatus ACCESS read-only STATUS mandatory DESCRIPTION "0003.0001.0009 This attribute defines the CMC health status being monitored by the chassis management card." ::= { drsStatusNowGroup 9 } drsChassisFrontPanelAmbientTemperature OBJECT-TYPE SYNTAX DellTemperatureReading ACCESS read-only STATUS mandatory DESCRIPTION "0003.0001.0010 This attribute defines the ambient temperature reading (in degrees Celsius) for the chassis front panel controller." ::= { drsStatusNowGroup 10 } drsCMCAmbientTemperature OBJECT-TYPE SYNTAX DellTemperatureReading ACCESS read-only STATUS mandatory DESCRIPTION "0003.0001.0011 This attribute defines the ambient temperature reading (in degrees Celsius) for the chassis management card." ::= { drsStatusNowGroup 11 } drsCMCProcessorTemperature OBJECT-TYPE SYNTAX DellTemperatureReading ACCESS read-only STATUS mandatory DESCRIPTION "0003.0001.0012 This attribute defines the temperature reading (in degrees Celsius) for the chassis management card processor." ::= { drsStatusNowGroup 12 } drsGlobalPrevStatus OBJECT-TYPE SYNTAX DellStatus ACCESS read-only STATUS mandatory DESCRIPTION "0003.0002.0001 This attribute defines the previous chassis status recorded by the chassis management card." ::= { drsStatusPrevGroup 1 } drsIOMPrevStatus OBJECT-TYPE SYNTAX DellStatus ACCESS read-only STATUS mandatory DESCRIPTION "0003.0002.0002 This attribute defines the previous IOM subsystem status recorded by the chassis management card." ::= { drsStatusPrevGroup 2 } drsKVMPrevStatus OBJECT-TYPE SYNTAX DellStatus ACCESS read-only STATUS mandatory DESCRIPTION "0003.0002.0003 This attribute defines the previous iKVM subsystem health status recorded by the chassis management card." ::= { drsStatusPrevGroup 3 } drsRedPrevStatus OBJECT-TYPE SYNTAX DellStatus ACCESS read-only STATUS mandatory DESCRIPTION "0003.0002.0004 This attribute defines the previous Redundancy status recorded by the chassis management card." ::= { drsStatusPrevGroup 4 } drsPowerPrevStatus OBJECT-TYPE SYNTAX DellStatus ACCESS read-only STATUS mandatory DESCRIPTION "0003.0002.0005 This attribute defines the previous power subsystem health status recorded by the chassis management card." ::= { drsStatusPrevGroup 5 } drsFanPrevStatus OBJECT-TYPE SYNTAX DellStatus ACCESS read-only STATUS mandatory DESCRIPTION "0003.0002.0006 This attribute defines the previous Fan health status being monitored by the chassis management card." ::= { drsStatusPrevGroup 6 } drsBladePrevStatus OBJECT-TYPE SYNTAX DellStatus ACCESS read-only STATUS mandatory DESCRIPTION "0003.0002.0007 This attribute defines the previous Blade subsystem health status recorded by the chassis management card." ::= { drsStatusPrevGroup 7 } drsTempPrevStatus OBJECT-TYPE SYNTAX DellStatus ACCESS read-only STATUS mandatory DESCRIPTION "0003.0001.0008 This attribute defines the Temp Sensor health status being monitored by the chassis management card." ::= { drsStatusPrevGroup 8 } drsCMCPrevStatus OBJECT-TYPE SYNTAX DellStatus ACCESS read-only STATUS mandatory DESCRIPTION "0003.0001.0009 This attribute defines the CMC health status being monitored by the chassis management card." ::= { drsStatusPrevGroup 9 } drsGlobalChangeTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "0003.0003.0001 This attribute defines the timestamp of the most recent global status change." ::= { drsStatusChangeGroup 1 } drsIOMChangeTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "0003.0003.0002 This attribute defines the timestamp of the most recent IOM status change." ::= { drsStatusChangeGroup 2 } drsKVMChangeTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "0003.0003.0003 This attribute defines the timestamp of the most recent iKVM status change." ::= { drsStatusChangeGroup 3 } drsRedChangeTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "0003.0003.0004 This attribute defines the timestamp of the most recent Redundancy status change." ::= { drsStatusChangeGroup 4 } drsPowerChangeTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "0003.0003.0005 This attribute defines the timestamp of the most recent power health status change." ::= { drsStatusChangeGroup 5 } drsFanChangeTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "0003.0003.0006 This attribute defines the timestamp of the most recent Fan health status change." ::= { drsStatusChangeGroup 6 } drsBladeChangeTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "0003.0003.0007 This attribute defines the timestamp of the most recent Blade health status change." ::= { drsStatusChangeGroup 7 } drsTempChangeTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "0003.0003.0008 This attribute defines the timestamp of the most recent Temp Sensor health status change." ::= { drsStatusChangeGroup 8 } drsCMCChangeTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "0003.0003.0009 This attribute defines the timestamp of the most recent CMC health status change." ::= { drsStatusChangeGroup 9 } ------------------------------------------------------------------------------- -- group: chassis power ------------------------------------------------------------------------------- drsCMCPowerTable OBJECT-TYPE SYNTAX SEQUENCE OF DrsCMCPowerTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "0004.0001 This object defines the CMC power table." ::= { drsChassisPowerGroup 1 } drsCMCPowerTableEntry OBJECT-TYPE SYNTAX DrsCMCPowerTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "0004.0001.0001 This object defines the CMC power table entry." INDEX { drsChassisIndex } ::= { drsCMCPowerTable 1 } drsCMCPSUTable OBJECT-TYPE SYNTAX SEQUENCE OF DrsCMCPSUTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "0004.0002 This object defines the CMC PSU table." ::= { drsChassisPowerGroup 2 } drsCMCPSUTableEntry OBJECT-TYPE SYNTAX DrsCMCPSUTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "0004.0002.0001 This object defines the CMC PSU table entry." INDEX { drsPSUChassisIndex, drsPSUIndex } ::= { drsCMCPSUTable 1 } ------------------------------------------------------------------------------- -- table: CMC power information ------------------------------------------------------------------------------- drsChassisIndex OBJECT-TYPE SYNTAX DellCMCPowerIndexRange ACCESS read-only STATUS mandatory DESCRIPTION "0004.0001.0001.0001 This attribute defines the index (one-based) of the associated chassis." ::= { drsCMCPowerTableEntry 1 } drsPotentialPower OBJECT-TYPE SYNTAX DellPowerReading ACCESS read-only STATUS mandatory DESCRIPTION "0004.0001.0001.0002 This attribute defines the power (in Watts) required by the chassis infrastructure, plus the sum of the maximum power requirements for all currently powered-on servers." ::= { drsCMCPowerTableEntry 2 } drsIdlePower OBJECT-TYPE SYNTAX DellPowerReading ACCESS read-only STATUS mandatory DESCRIPTION "0004.0001.0001.0003 This attribute defines the power (in Watts) required by the chassis infrastructure, plus the sum of the minimum power requirements for all currently powered-on servers." ::= { drsCMCPowerTableEntry 3 } drsMaxPowerSpecification OBJECT-TYPE SYNTAX DellPowerReading ACCESS read-only STATUS mandatory DESCRIPTION "0004.0001.0001.0004 This attribute defines the power limit (in Watts) at which server throttling will take place." ::= { drsCMCPowerTableEntry 4 } drsPowerSurplus OBJECT-TYPE SYNTAX DellPowerReading ACCESS read-only STATUS mandatory DESCRIPTION "0004.0001.0001.0005 This attribute defines the power surplus (in Watts) remaining above the drsPotentialPower reading." ::= { drsCMCPowerTableEntry 5 } drsKWhCumulative OBJECT-TYPE SYNTAX DellPowerReading ACCESS read-only STATUS mandatory DESCRIPTION "0004.0001.0001.0006 This attribute defines the cumulative chassis power usage (in KWh) since last reset." ::= { drsCMCPowerTableEntry 6 } drsKWhCumulativeTime OBJECT-TYPE SYNTAX DellTimestamp ACCESS read-only STATUS mandatory DESCRIPTION "0004.0001.0001.0007 This attribute defines the timestamp of the most recent chassis power accumulator reset." ::= { drsCMCPowerTableEntry 7 } drsWattsPeakUsage OBJECT-TYPE SYNTAX DellPowerReading ACCESS read-only STATUS mandatory DESCRIPTION "0004.0001.0001.0008 This attribute defines the chassis peak power usage (in Watts) since last reset." ::= { drsCMCPowerTableEntry 8 } drsWattsPeakTime OBJECT-TYPE SYNTAX DellTimestamp ACCESS read-only STATUS mandatory DESCRIPTION "0004.0001.0001.0009 This attribute defines the timestamp of the most recent chassis peak power usage." ::= { drsCMCPowerTableEntry 9 } drsWattsMinUsage OBJECT-TYPE SYNTAX DellPowerReading ACCESS read-only STATUS mandatory DESCRIPTION "0004.0001.0001.0010 This attribute defines the chassis mimimum power usage (in Watts) since last reset." ::= { drsCMCPowerTableEntry 10 } drsWattsMinTime OBJECT-TYPE SYNTAX DellTimestamp ACCESS read-only STATUS mandatory DESCRIPTION "0004.0001.0001.0011 This attribute defines the timestamp of the most recent chassis minimum power usage." ::= { drsCMCPowerTableEntry 11 } drsWattsResetTime OBJECT-TYPE SYNTAX DellTimestamp ACCESS read-only STATUS mandatory DESCRIPTION "0004.0001.0001.0012 This attribute defines the timestamp of the most recent reset of the chassis min/peak Watts readings." ::= { drsCMCPowerTableEntry 12 } drsWattsReading OBJECT-TYPE SYNTAX DellPowerReading ACCESS read-only STATUS mandatory DESCRIPTION "0004.0001.0001.0013 This attribute defines the instantaneous chassis power usage (in Watts)." ::= { drsCMCPowerTableEntry 13 } drsAmpsReading OBJECT-TYPE SYNTAX DellPowerReading ACCESS read-only STATUS mandatory DESCRIPTION "0004.0001.0001.0014 This attribute defines the instantaneous chassis current usage (in Watts)." ::= { drsCMCPowerTableEntry 14 } ------------------------------------------------------------------------------- -- table: CMC PSU info ------------------------------------------------------------------------------- drsPSUChassisIndex OBJECT-TYPE SYNTAX DellCMCPowerIndexRange ACCESS read-only STATUS mandatory DESCRIPTION "0004.0002.0001.0001 This attribute defines the index (one-based) of the associated chassis." ::= { drsCMCPSUTableEntry 1 } drsPSUIndex OBJECT-TYPE SYNTAX DellCMCPSUIndexRange ACCESS read-only STATUS mandatory DESCRIPTION "0004.0002.0001.0002 This attribute defines the index (one-based) of the associated CMC PSU." ::= { drsCMCPSUTableEntry 2 } drsPSULocation OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "0004.0002.0001.0003 This attribute defines the location of the CMC PSU." ::= { drsCMCPSUTableEntry 3 } drsPSUMonitoringCapable OBJECT-TYPE SYNTAX DellCMCPSUCapable ACCESS read-only STATUS mandatory DESCRIPTION "0004.0002.0001.0004 This attribute defines the PSU Monitoring capabilities, or the absence of a PSU in this location." ::= { drsCMCPSUTableEntry 4 } drsPSUVoltsReading OBJECT-TYPE SYNTAX DellPowerReading ACCESS read-only STATUS mandatory DESCRIPTION "0004.0002.0001.0005 This attribute defines the instantaneous PSU Voltage reading." ::= { drsCMCPSUTableEntry 5 } drsPSUAmpsReading OBJECT-TYPE SYNTAX DellPowerReading ACCESS read-only STATUS mandatory DESCRIPTION "0004.0002.0001.0006 This attribute defines the instantaneous PSU Current reading." ::= { drsCMCPSUTableEntry 6 } drsPSUWattsReading OBJECT-TYPE SYNTAX DellPowerReading ACCESS read-only STATUS mandatory DESCRIPTION "0004.0002.0001.0007 This attribute defines the instantaneous PSU Wattage reading." ::= { drsCMCPSUTableEntry 7 } ------------------------------------------------------------------------------- -- group: chassis servers ------------------------------------------------------------------------------- drsCMCServerTable OBJECT-TYPE SYNTAX SEQUENCE OF DrsCMCServerTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "0005.0001 This object defines the CMC server table." ::= { drsChassisServerGroup 1 } drsCMCServerTableEntry OBJECT-TYPE SYNTAX DrsCMCServerTableEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "0005.0001.0001 This object defines the CMC server table entry." INDEX { drsServerIndex } ::= { drsCMCServerTable 1 } ------------------------------------------------------------------------------- -- table: CMC Server info ------------------------------------------------------------------------------- drsServerIndex OBJECT-TYPE SYNTAX DellCMCServerIndexRange ACCESS read-only STATUS mandatory DESCRIPTION "0005.0001.0001.0001 This attribute defines the index (one-based) of the associated CMC server." ::= { drsCMCServerTableEntry 1 } drsServerMonitoringCapable OBJECT-TYPE SYNTAX DellCMCServerCapable ACCESS read-only STATUS mandatory DESCRIPTION "0005.0001.0001.0002 This attribute defines the server monitoring capabilities, or the absence of a server in this location." ::= { drsCMCServerTableEntry 2 } drsServerServiceTag OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "0005.0001.0001.0003 This attribute defines the Service Tag of the CMC server." ::= { drsCMCServerTableEntry 3 } drsServerSlotName OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "0005.0001.0001.0004 This attribute defines the Slot Name of the CMC server." ::= { drsCMCServerTableEntry 4 } drsServerSlotNumber OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "0005.0001.0001.0005 This attribute defines the Chassis Slot Number of the CMC server." ::= { drsCMCServerTableEntry 5 } drsServerNodeID OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "0005.0001.0001.0006 This attribute defines the Node ID of the CMC server. The Node ID provides a unique identifier for the server." ::= { drsCMCServerTableEntry 6 } ------------------------------------------------------------------------------- -- group: Chassis Alerts 1 ------------------------------------------------------------------------------- drsCASubSystem OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "0020.0010.0001 This attribute defines the Sub-System Name of the CMC Alert" ::= { drsChassisAlertVariables 1 } drsCASSCurrStatus OBJECT-TYPE SYNTAX DellStatus ACCESS read-only STATUS mandatory DESCRIPTION "0020.0010.0002 This attribute defines the Current Status of the Alerting Sub-System" ::= { drsChassisAlertVariables 2 } drsCASSPrevStatus OBJECT-TYPE SYNTAX DellStatus ACCESS read-only STATUS mandatory DESCRIPTION "0020.0010.0003 This attribute defines the Previous Status of the Alerting Sub-System" ::= { drsChassisAlertVariables 3 } drsCASSChangeTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "0020.0010.0004 This attribute defines the Timestamp of Most Recent Change of the Alerting Sub-System" ::= { drsChassisAlertVariables 4 } drsCAMessage OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "0020.0010.0005 This attribute defines the CSSD message of the CMC Alert" ::= { drsChassisAlertVariables 5 } alertCMCTestTrap TRAP-TYPE ENTERPRISE drsOutofBandGroup DESCRIPTION "The CMC has generated a test trap" --#TYPE "CMC Test Trap" --#SUMMARY "CMC Test Trap" --#SEVERITY INFORMATIONAL --#CATEGORY Error Events ::= 2000 alertCMCNormalTrap TRAP-TYPE ENTERPRISE drsOutofBandGroup VARIABLES { drsProductChassisName, drsProductChassisLocation, drsGlobalCurrStatus, drsCASubSystem, drsCASSCurrStatus, drsCASSPrevStatus, drsCASSChangeTime, drsCAMessage } DESCRIPTION "The CMC reported a return-to-normal or informational event." --#TYPE "CMC Return-to-Normal / Informational Trap" --#SUMMARY "Return-to-Normal / Informational Trap from CMC in system %s in location %s, message: %s" --#ARGUMENTS {0,1,7} --#SEVERITY NORMAL --#CATEGORY Error Events ::= 2002 alertCMCWarningTrap TRAP-TYPE ENTERPRISE drsOutofBandGroup VARIABLES { drsProductChassisName, drsProductChassisLocation, drsGlobalCurrStatus, drsCASubSystem, drsCASSCurrStatus, drsCASSPrevStatus, drsCASSChangeTime, drsCAMessage } DESCRIPTION "The CMC reported a warning event." --#TYPE "CMC Warning Trap" --#SUMMARY "Warning Trap from CMC in system %s in location %s, message: %s" --#ARGUMENTS {0,1,7} --#SEVERITY WARNING --#CATEGORY Error Events ::= 2003 alertCMCCriticalTrap TRAP-TYPE ENTERPRISE drsOutofBandGroup VARIABLES { drsProductChassisName, drsProductChassisLocation, drsGlobalCurrStatus, drsCASubSystem, drsCASSCurrStatus, drsCASSPrevStatus, drsCASSChangeTime, drsCAMessage } DESCRIPTION "The CMC reported a critical event." --#TYPE "CMC Critical Trap" --#SUMMARY "Critical Trap from CMC in system %s in location %s, message: %s" --#ARGUMENTS {0,1,7} --#SEVERITY CRITICAL --#CATEGORY Error Events ::= 2004 alertCMCNonRecoverableTrap TRAP-TYPE ENTERPRISE drsOutofBandGroup VARIABLES { drsProductChassisName, drsProductChassisLocation, drsGlobalCurrStatus, drsCASubSystem, drsCASSCurrStatus, drsCASSPrevStatus, drsCASSChangeTime, drsCAMessage } DESCRIPTION "The CMC reported a catastrophic event." --#TYPE "CMC Non-Recoverable Trap" --#SUMMARY "Non-Recoverable Trap from CMC in system %s in location %s, message: %s" --#ARGUMENTS {0,1,7} --#SEVERITY NON-RECOVERABLE --#CATEGORY Error Events ::= 2005 ------------------------------------------------------------------------------- -- group: Chassis Alerts 2 ------------------------------------------------------------------------------- drsCA2MessageID OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) ACCESS read-only STATUS mandatory DESCRIPTION "Message ID of the alert." ::= { drsChassisAlert2Variables 1 } drsCA2Message OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "Message describing the alert." ::= { drsChassisAlert2Variables 2 } drsCA2MessageArgs OBJECT-TYPE SYNTAX DellString ACCESS read-only STATUS mandatory DESCRIPTION "Concatenated set of strings representing any message arguments that were used to construct the alert message. Each message argument string is enclosed in double quotes, and there is a comma after the ending double quote of each message argument string, except the last one. Any double quotes found within a message argument string were preprocessed and changed to single quotes." ::= { drsChassisAlert2Variables 3 } drsCA2AlertStatus OBJECT-TYPE SYNTAX DellStatus ACCESS read-only STATUS mandatory DESCRIPTION "Status of the alert." ::= { drsChassisAlert2Variables 4 } drsCA2FQDD OBJECT-TYPE SYNTAX DisplayString (SIZE (0..512)) ACCESS read-only STATUS mandatory DESCRIPTION "Fully qualified device descriptor of device causing the alert." ::= { drsChassisAlert2Variables 5 } ------------------------------------------------------------------------------ -- Chassis Alerts 2: System: Amperage Probe Traps -- -- Category: System/1 -- Subcategory: AMP/16 ------------------------------------------------------------------------------ alert2AmperageProbeNormal TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Current sensor reading is within range." --#TYPE "System: Amperage Normal" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 2179 alert2AmperageProbeWarning TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Current sensor has detected a warning value." --#TYPE "System: Amperage Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2178 alert2AmperageProbeFailure TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Current sensor has detected a failure value." --#TYPE "System: Amperage Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2177 ------------------------------------------------------------------------------ -- Chassis Alerts 2: System: Battery Traps -- -- Category: System/1 -- Subcategory: BAT/22 ------------------------------------------------------------------------------ alert2BatteryNormal TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Battery state has returned to normal; or battery presence had been detected." --#TYPE "System: Battery Normal" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 2227 alert2BatteryWarning TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Battery is low." --#TYPE "System: Battery Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2226 alert2BatteryFailure TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Battery has failed or battery is absent." --#TYPE "System: Battery Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2225 ------------------------------------------------------------------------------ -- Chassis Alerts 2: System: Cable Traps -- -- Category: System/1 -- Subcategory: CBL/43 ------------------------------------------------------------------------------ alert2CableFailure TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Cable failure." --#TYPE "System: Cable Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2393 ------------------------------------------------------------------------------ -- Chassis Alerts 2: System: CMC Traps -- -- Category: System/1 -- Subcategory: CMC/62 ------------------------------------------------------------------------------ alert2CMCWarning TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Chassis Management Controller detected a warning." --#TYPE "System: CMC Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2546 alert2CMCFailure TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Chassis Management Controller detected an error." --#TYPE "System: CMC Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2545 ------------------------------------------------------------------------------ -- Chassis Alerts 2: System: Fan Traps -- -- Category: System/1 -- Subcategory: FAN/13 ------------------------------------------------------------------------------ alert2FanInformation TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Fan information." --#TYPE "System: Fan Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 2155 alert2FanWarning TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Fan warning." --#TYPE "System: Fan Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2154 alert2FanFailure TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Fan failure." --#TYPE "System: Fan Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2153 ------------------------------------------------------------------------------ -- Chassis Alerts 2: System: Hardware Configuration Traps -- -- Category: System/1 -- Subcategory: HWC/35 ------------------------------------------------------------------------------ alert2HardwareConfigurationInformation TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Hardware configuration information." --#TYPE "System: Hardware Configuration Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 2331 alert2HardwareConfigurationWarning TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Hardware configuration warning." --#TYPE "System: Hardware Configuration Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2330 alert2HardwareConfigurationFailure TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Hardware configuration failure or critical event." --#TYPE "System: Hardware Configuration Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2329 ------------------------------------------------------------------------------ -- Chassis Alerts 2: System: IO Virtualization Traps -- -- Category: System/1 -- Subcategory: IOV/63 ------------------------------------------------------------------------------ alert2IOVirtualizationInformation TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "IO Virtualization information." --#TYPE "System: IO Virtualization Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 2555 alert2IOVirtualizationWarning TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "IO Virtualization warning." --#TYPE "System: IO Virtualization Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2554 alert2IOVirtualizationFailure TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "IO Virtualization failure or critical event." --#TYPE "System: IO Virtualization Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2553 ------------------------------------------------------------------------------ -- Chassis Alerts 2: System: Link Status Traps -- -- Category: System/1 -- Subcategory: LNK/25 ------------------------------------------------------------------------------ alert2LinkStatusInformation TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Link status information." --#TYPE "System: Link Status Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 2251 alert2LinkStatusWarning TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Link status warning." --#TYPE "System: Link Status Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2250 alert2LinkStatusFailure TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Link status failure or critical event." --#TYPE "System: Link Status Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2249 ------------------------------------------------------------------------------ -- Chassis Alerts 2: System: PCI Device Traps -- -- Category: System/1 -- Subcategory: PCI/46 ------------------------------------------------------------------------------ alert2PCIDeviceInformation TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "PCI device information." --#TYPE "System: PCI Device Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 2419 alert2PCIDeviceWarning TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "PCI device warning." --#TYPE "System: PCI Device Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2418 alert2PCIDeviceFailure TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "PCI device failure or critical event." --#TYPE "System: PCI Device Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2417 ------------------------------------------------------------------------------ -- Chassis Alerts 2: System: Power Supply Traps -- -- Category: System/1 -- Subcategory: PSU/17 ------------------------------------------------------------------------------ alert2PowerSupplyNormal TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Power supply has returned to normal." --#TYPE "System: Power Supply Normal" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 2187 alert2PowerSupplyWarning TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Power supply has detected a warning." --#TYPE "System: Power Supply Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2186 alert2PowerSupplyFailure TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Power supply has detected a failure." --#TYPE "System: Power Supply Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2185 ------------------------------------------------------------------------------ -- Chassis Alerts 2: System: Power Supply Absent Traps -- -- Category: System/1 -- Subcategory: PSUA/52 ------------------------------------------------------------------------------ alert2PowerSupplyAbsent TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Power supply is absent." --#TYPE "System: Power Supply Absent" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2465 ------------------------------------------------------------------------------ -- Chassis Alerts 2: System: Power Usage Traps -- -- Category: System/1 -- Subcategory: PWR/28 ------------------------------------------------------------------------------ alert2PowerUsageInformation TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Power usage information." --#TYPE "System: Power Usage Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 2275 alert2PowerUsageWarning TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Power usage warning." --#TYPE "System: Power Usage Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2274 ------------------------------------------------------------------------------ -- Chassis Alerts 2: System: Redundancy Traps -- -- Category: System/1 -- Subcategory: RDU/53 ------------------------------------------------------------------------------ alert2RedundancyInformation TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Redundancy information." --#TYPE "System: Redundancy Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 2475 alert2RedundancyDegraded TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Redundancy is degraded." --#TYPE "System: Redundancy Degraded" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2474 alert2RedundancyLost TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Redundancy is lost." --#TYPE "System: Redundancy Lost" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2473 ------------------------------------------------------------------------------ -- Chassis Alerts 2: System: Security Event Traps -- -- Category: System/1 -- Subcategory: SEC/42 ------------------------------------------------------------------------------ alert2SecurityInformation TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Security information." --#TYPE "System: Security Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 2387 alert2SecurityWarning TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Security warning." --#TYPE "System: Security Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 2386 alert2SecurityFailure TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Security failure or critical event." --#TYPE "System: Security Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Error Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 2385 ------------------------------------------------------------------------------ -- Chassis Alerts 2: System: System Event Log Traps -- -- Category: System/1 -- Subcategory: SEL/41 ------------------------------------------------------------------------------ alert2SystemEventLogInformation TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "System Event Log information." --#TYPE "System: System Event Log Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 2379 alert2SystemEventLogWarning TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "System Event Log warning." --#TYPE "System: System Event Log Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2378 alert2SystemEventLogFailure TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "System Event Log failure or critical event." --#TYPE "System: System Event Log Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Error Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 2377 ------------------------------------------------------------------------------ -- Chassis Alerts 2: System: Software Configuration Traps -- -- Category: System/1 -- Subcategory: SWC/36 ------------------------------------------------------------------------------ alert2SoftwareConfigurationInformation TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Software configuration information." --#TYPE "System: Software Configuration Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 2339 alert2SoftwareConfigurationWarning TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Software configuration warning." --#TYPE "System: Software Configuration Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2338 ------------------------------------------------------------------------------ -- Chassis Alerts 2: System: Temperature Probe Traps -- -- Category: System/1 -- Subcategory: TMP/14 ------------------------------------------------------------------------------ alert2TemperatureProbeNormal TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Temperature sensor value is within range." --#TYPE "System: Temperature Normal" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 2163 alert2TemperatureProbeWarning TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Temperature sensor has detected a warning value." --#TYPE "System: Temperature Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2162 alert2TemperatureProbeFailure TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Temperature sensor has detected a failure value." --#TYPE "System: Temperature Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2161 ------------------------------------------------------------------------------ -- Chassis Alerts 2: System: Voltage Probe Traps -- -- Category: System/1 -- Subcategory: VLT/15 ------------------------------------------------------------------------------ alert2VoltageProbeNormal TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Voltage sensor reading is within range." --#TYPE "System: Voltage Normal" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 2171 alert2VoltageProbeWarning TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Voltage sensor has detected a warning value." --#TYPE "System: Voltage Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2170 alert2VoltageProbeFailure TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Voltage sensor has detected a failure value." --#TYPE "System: Voltage Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 2169 ------------------------------------------------------------------------------- -- Chassis Alerts 2: Storage: Battery Traps -- -- Category: Storage/2 -- Subcategory: BAT/22 ------------------------------------------------------------------------------- alert2StorageBatteryInformation TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Storage Battery information." --#TYPE "Storage: Battery Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Error Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 4275 alert2StorageBatteryWarning TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Storage Battery warning." --#TYPE "Storage: Battery Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 4274 alert2StorageBatteryFailure TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Storage Battery failure." --#TYPE "Storage: Battery Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Error Events" --#STATE FAILED --#STATUS MANDATORY ::= 4273 ------------------------------------------------------------------------------ -- Chassis Alerts 2: Storage: Controller Traps -- -- Category: Storage/2 -- Subcategory: CTL/29 ------------------------------------------------------------------------------ alert2StorageControllerInformation TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Storage Controller information." --#TYPE "Storage: Controller Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Error Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 4331 alert2StorageControllerWarning TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Storage Controller warning." --#TYPE "Storage: Controller Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 4330 alert2StorageControllerFailure TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Storage Controller failure." --#TYPE "Storage: Controller Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Error Events" --#STATE FAILED --#STATUS MANDATORY ::= 4329 ------------------------------------------------------------------------------ -- Chassis Alerts 2: Storage: Enclosure Traps -- -- Category: Storage/2 -- Subcategory: ENC/30 ------------------------------------------------------------------------------ alert2StorageEnclosureInformation TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Storage Enclosure information." --#TYPE "Storage: Enclosure Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Error Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 4339 alert2StorageEnclosureWarning TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Storage Enclosure warning." --#TYPE "Storage: Enclosure Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 4338 alert2StorageEnclosureFailure TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Storage Enclosure failure." --#TYPE "Storage: Enclosure Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Error Events" --#STATE FAILED --#STATUS MANDATORY ::= 4337 ------------------------------------------------------------------------------ -- Chassis Alerts 2: Storage: Fan Traps -- -- Category: Storage/2 -- Subcategory: FAN/13 ------------------------------------------------------------------------------ alert2StorageFanInformation TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Storage Fan information." --#TYPE "Storage: Fan Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Error Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 4203 alert2StorageFanWarning TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Storage Fan warning." --#TYPE "Storage: Fan Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 4202 alert2StorageFanFailure TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Storage Fan failure." --#TYPE "Storage: Fan Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Error Events" --#STATE FAILED --#STATUS MANDATORY ::= 4201 ------------------------------------------------------------------------------ -- Chassis Alerts 2: Storage: Physical Disk Traps -- -- Category: Storage/2 -- Subcategory: PDR/31 ------------------------------------------------------------------------------ alert2StoragePhysicalDiskInformation TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Storage Physical disk information." --#TYPE "Storage: Physical Disk Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Error Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 4347 alert2StoragePhysicalDiskWarning TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Storage Physical disk warning." --#TYPE "Storage: Physical Disk Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 4346 alert2StoragePhysicalDiskFailure TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Storage Physical disk failure." --#TYPE "Storage: Physical Disk Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Error Events" --#STATE FAILED --#STATUS MANDATORY ::= 4345 ------------------------------------------------------------------------------ -- Chassis Alerts 2: Storage: Power Supply Traps -- -- Category: Storage/2 -- Subcategory: PSU/17 ------------------------------------------------------------------------------ alert2StoragePowerSupplyInformation TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Storage Power supply information." --#TYPE "Storage: Power Supply Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Error Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 4235 alert2StoragePowerSupplyWarning TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Storage Power supply warning." --#TYPE "Storage: Power Supply Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 4234 alert2StoragePowerSupplyFailure TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Storage Power supply failure." --#TYPE "Storage: Power Supply Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Error Events" --#STATE FAILED --#STATUS MANDATORY ::= 4233 ------------------------------------------------------------------------------ -- Chassis Alerts 2: Storage: Storage Management Status Traps -- -- Category: Storage/2 -- Subcategory: STOR/10 ------------------------------------------------------------------------------ alert2StorageManagementInformation TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Storage Management information. There is no global status change associated with this trap." --#TYPE "Storage: Storage Management Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Error Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 4179 alert2StorageManagementWarning TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Storage Management has detected a device independent warning condition. There is no global status change associated with this trap." --#TYPE "Storage: Storage Management Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 4178 alert2StorageManagementFailure TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Storage Management has detected a device independent error condition. There is no global status change associated with this trap." --#TYPE "Storage: Storage Management Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Error Events" --#STATE FAILED --#STATUS MANDATORY ::= 4177 ------------------------------------------------------------------------------ -- Chassis Alerts 2: Storage: Temperature Probe Traps -- -- Category: Storage/2 -- Subcategory: TMP/14 ------------------------------------------------------------------------------ alert2StorageTemperatureProbeInformation TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Storage Temperature probe information." --#TYPE "Storage: Temperature Probe Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Error Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 4211 alert2StorageTemperatureProbeWarning TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Storage Temperature probe warning." --#TYPE "Storage: Temperature Probe Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 4210 alert2StorageTemperatureProbeFailure TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Storage Temperature probe failure." --#TYPE "Storage: Temperature Probe Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Error Events" --#STATE FAILED --#STATUS MANDATORY ::= 4209 ------------------------------------------------------------------------------ -- Chassis Alerts 2: Storage: Virtual Disk Traps -- -- Category: Storage/2 -- Subcategory: VDR/32 ------------------------------------------------------------------------------ alert2StorageVirtualDiskInformation TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Storage Virtual disk information." --#TYPE "Storage: Virtual Disk Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Error Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 4355 alert2StorageVirtualDiskWarning TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Storage Virtual disk warning." --#TYPE "Storage: Virtual Disk Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 4354 alert2StorageVirtualDiskFailure TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Storage Virtual disk failure." --#TYPE "Storage: Virtual Disk Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Error Events" --#STATE FAILED --#STATUS MANDATORY ::= 4353 ------------------------------------------------------------------------------ -- Chassis Alerts 2: Audit: CMC Traps -- -- Category: Audit/4 -- Subcategory: CMC/62 ------------------------------------------------------------------------------ alert2CMCAuditInformation TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Chassis Management Controller audit information." --#TYPE "Audit: CMC Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 8691 alert2CMCAuditWarning TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Chassis Management Controller audit warning." --#TYPE "Audit: CMC Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 8690 alert2CMCAuditFailure TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Chassis Management Controller audit failure or critical event." --#TYPE "Audit: CMC Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 8689 ------------------------------------------------------------------------------ -- Chassis Alerts 2: Audit: IO Virtualization Traps -- -- Category: Audit/4 -- Subcategory: IOV/63 ------------------------------------------------------------------------------ alert2IOVirtualizationAuditWarning TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "IO Virtualization audit warning." --#TYPE "Audit: IO Virtualization Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 8698 ------------------------------------------------------------------------------ -- Chassis Alerts 2: Audit: License Traps -- -- Category: Audit/4 -- Subcategory: LIC/40 ------------------------------------------------------------------------------ alert2LicenseInformation TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "License information." --#TYPE "Audit: License Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 8515 alert2LicenseWarning TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "License warning." --#TYPE "Audit: License Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 8514 alert2LicenseFailure TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "License failure." --#TYPE "Audit: License Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 8513 ------------------------------------------------------------------------------ -- Chassis Alerts 2: Audit: PCI Device Traps -- -- Category: Audit/4 -- Subcategory: PCI/46 ------------------------------------------------------------------------------ alert2PCIDeviceAuditWarning TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "PCI device audit warning." --#TYPE "Audit: PCI Device Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 8562 ------------------------------------------------------------------------------ -- Chassis Alerts 2: Audit: Power Supply Traps -- -- Category: Audit/4 -- Subcategory: PSU/17 ------------------------------------------------------------------------------ alert2PowerSupplyAuditWarning TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Power Supply audit warning." --#TYPE "Audit: Power Supply Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 8330 alert2PowerSupplyAuditFailure TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Power Supply audit failure or critical event." --#TYPE "Audit: Power Supply Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 8329 ------------------------------------------------------------------------------ -- Chassis Alerts 2: Audit: Power Usage Traps -- -- Category: Audit/4 -- Subcategory: PWR/28 ------------------------------------------------------------------------------ alert2PowerUsageAuditWarning TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Power usage audit warning." --#TYPE "Audit: Power Usage Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 8418 alert2PowerUsageAuditFailure TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Power usage audit failure or critical event." --#TYPE "Audit: Power Usage Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 8417 ------------------------------------------------------------------------------ -- Chassis Alerts 2: Audit: Software Change Traps -- -- Category: Audit/4 -- Subcategory: SWU/21 ------------------------------------------------------------------------------ alert2SoftwareChangeAuditFailure TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Software change audit failure or critical event." --#TYPE "Audit: Software Change Failure" --#SEVERITY CRITICAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Error Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 8361 ------------------------------------------------------------------------------ -- Chassis Alerts 2: Configuration: IO Virtualization Traps -- -- Category: Configuration/5 -- Subcategory: IOV/63 ------------------------------------------------------------------------------ alert2IOVConfigurationInformation TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "IO Virtualization configuration information." --#TYPE "Configuration: IO Virtualization Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 10747 alert2IOVConfigurationWarning TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "IO Virtualization configuration warning." --#TYPE "Configuration: IO Virtualization Warning" --#SEVERITY MINOR --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Status Events" --#STATE DEGRADED --#STATUS MANDATORY ::= 10746 ------------------------------------------------------------------------------ -- Chassis Alerts 2: Configuration: PCI Device Traps -- -- Category: Configuration/5 -- Subcategory: PCI/46 ------------------------------------------------------------------------------ alert2PCIDeviceConfigurationInformation TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "PCI device configuration information." --#TYPE "Configuration: PCI Device Information" --#SEVERITY INFORMATIONAL --#SUMMARY "Message ID: %s, Message: %s," --#SUMMARY "Device Status: %d, Device FQDD: %s," --#SUMMARY "Chassis Service Tag: %s, Chassis Name: %s," --#SUMMARY "Chassis Location: %s, Global Status: %d" --#ARGUMENTS {0, 1, 3, 4, 7, 5, 8} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 10611 ------------------------------------------------------------------------------ -- Chassis Alerts 2: Configuration: Test Traps -- -- Category: Configuration/5 -- Subcategory: TST/19 ------------------------------------------------------------------------------ alert2CMCTestTrap TRAP-TYPE ENTERPRISE drsCMCAlert2Group VARIABLES { drsCA2MessageID, drsCA2Message, drsCA2MessageArgs, drsCA2AlertStatus, drsCA2FQDD, drsProductChassisName, drsProductChassisLocation, drsChassisServiceTag, drsGlobalCurrStatus } DESCRIPTION "Test trap generated by CMC in response to a user request." --#TYPE "Configuration: CMC Test Trap" --#SEVERITY INFORMATIONAL --#SUMMARY "%s" --#ARGUMENTS {1} --#CATEGORY "Status Events" --#STATE OPERATIONAL --#STATUS MANDATORY ::= 10395 ------------------------------------------------------------------------------- -- group: Legacy Alerts ------------------------------------------------------------------------------- drsAlertSystem OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..255)) ACCESS read-only STATUS mandatory DESCRIPTION "5000.0010.0001 Name of the system generating the alert." --DEFAULT get-function-async get_%n_async --DEFAULT next-function-async std_next_async ::= { drsAlertVariables 1 } drsAlertTableIndexOID OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "5000.0010.0002 0.0" --DEFAULT get-function-async get_OID_null_async --DEFAULT next-function-async std_next_async ::= { drsAlertVariables 2 } drsAlertMessage OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..1024)) ACCESS read-only STATUS mandatory DESCRIPTION "5000.0010.0003 Message describing the alert." --DEFAULT get-function-async get_string_null_async --DEFAULT next-function-async std_next_async ::= { drsAlertVariables 3 } drsAlertCurrentStatus OBJECT-TYPE SYNTAX DellStatus ACCESS read-only STATUS mandatory DESCRIPTION "5000.0010.0004 Current status of object causing the alert." --DEFAULT get-function-async get_dellstatus_unknow_async --DEFAULT next-function-async std_next_async ::= { drsAlertVariables 4 } drsAlertPreviousStatus OBJECT-TYPE SYNTAX DellStatus ACCESS read-only STATUS mandatory DESCRIPTION "5000.0010.0005 Previous status of object causing the alert." --DEFAULT get-function-async get_dellstatus_unknow_async --DEFAULT next-function-async std_next_async ::= { drsAlertVariables 5 } drsAlertData OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..1024)) ACCESS read-only STATUS mandatory DESCRIPTION "5000.0010.0006 Alert data." --DEFAULT get-function-async get_string_null_async --DEFAULT next-function-async std_next_async ::= { drsAlertVariables 6 } alertDrscTestTrapEvent TRAP-TYPE ENTERPRISE drsOutofBandGroup VARIABLES { drsAlertSystem, drsAlertTableIndexOID, drsAlertMessage, drsAlertCurrentStatus, drsAlertPreviousStatus, drsAlertData } DESCRIPTION "The RAC generated a test trap event in response to a user request." --#TYPE "Dell RAC Test TRAP Event" --#SUMMARY "%s" --#ARGUMENTS {2} --#SEVERITY INFORMATIONAL --#CATEGORY Status Events ::= 1001 alertDrscAuthError TRAP-TYPE ENTERPRISE drsOutofBandGroup VARIABLES { drsAlertSystem, drsAlertTableIndexOID, drsAlertMessage, drsAlertCurrentStatus, drsAlertPreviousStatus, drsAlertData } DESCRIPTION "The RAC Authentication Failures during a time period have Exceeded a Threshold." --#TYPE "Dell RAC Authentication Error" --#SUMMARY "%s" --#ARGUMENTS {2} --#SEVERITY MINOR --#CATEGORY Error Events ::= 1002 alertDrscLostESM TRAP-TYPE ENTERPRISE drsOutofBandGroup VARIABLES { drsAlertSystem, drsAlertTableIndexOID, drsAlertMessage, drsAlertCurrentStatus, drsAlertPreviousStatus, drsAlertData } DESCRIPTION "The RAC cannot communicate with the baseboard management controller (ESM)." --#TYPE "Dell RAC Lost Communication with ESM" --#SUMMARY "%s" --#ARGUMENTS {2} --#SEVERITY MINOR --#CATEGORY Error Events ::= 1003 alertDrscFoundESM TRAP-TYPE ENTERPRISE drsOutofBandGroup VARIABLES { drsAlertSystem, drsAlertTableIndexOID, drsAlertMessage, drsAlertCurrentStatus, drsAlertPreviousStatus, drsAlertData } DESCRIPTION "The RAC is communicating normally with the baseboard management controller (ESM)." --#TYPE "Dell RAC Communication with ESM is OK" --#SUMMARY "%s" --#ARGUMENTS {2} --#SEVERITY INFORMATIONAL --#CATEGORY Error Events ::= 1004 alertDrscPowerOff TRAP-TYPE ENTERPRISE drsOutofBandGroup VARIABLES { drsAlertSystem, drsAlertTableIndexOID, drsAlertMessage, drsAlertCurrentStatus, drsAlertPreviousStatus, drsAlertData } DESCRIPTION "The RAC has detected a System power state change to powered-off." --#TYPE "Dell RAC Detected System Powered-Off" --#SUMMARY "%s" --#ARGUMENTS {2} --#SEVERITY CRITICAL --#CATEGORY Error Events ::= 1005 alertDrscPowerOn TRAP-TYPE ENTERPRISE drsOutofBandGroup VARIABLES { drsAlertSystem, drsAlertTableIndexOID, drsAlertMessage, drsAlertCurrentStatus, drsAlertPreviousStatus, drsAlertData } DESCRIPTION "The RAC has detected a system power state change to powered-on." --#TYPE "Dell RAC Detected System Powered-On" --#SUMMARY "%s" --#ARGUMENTS {2} --#SEVERITY INFORMATIONAL --#CATEGORY Error Events ::= 1006 alertDrscWatchdogExpired TRAP-TYPE ENTERPRISE drsOutofBandGroup VARIABLES { drsAlertSystem, drsAlertTableIndexOID, drsAlertMessage, drsAlertCurrentStatus, drsAlertPreviousStatus, drsAlertData } DESCRIPTION "The RAC has detected that the system watchdog has expired indicating a system hang." --#TYPE "Dell RAC Detected Watchdog Expired" --#SUMMARY "%s" --#ARGUMENTS {2} --#SEVERITY CRITICAL --#CATEGORY Error Events ::= 1007 alertDrscBattLow TRAP-TYPE ENTERPRISE drsOutofBandGroup VARIABLES { drsAlertSystem, drsAlertTableIndexOID, drsAlertMessage, drsAlertCurrentStatus, drsAlertPreviousStatus, drsAlertData } DESCRIPTION "The RAC Battery charge is below 25% indicating that the battery may only be able to power the DRSC for 8-10 minutes." --#TYPE "Dell RAC Battery Charge Low" --#SUMMARY "%s" --#ARGUMENTS {2} --#SEVERITY MINOR --#CATEGORY Error Events ::= 1008 alertDrscTempNormal TRAP-TYPE ENTERPRISE drsOutofBandGroup VARIABLES { drsAlertSystem, drsAlertTableIndexOID, drsAlertMessage, drsAlertCurrentStatus, drsAlertPreviousStatus, drsAlertData } DESCRIPTION "The RAC Temperature probe has retured to a normal value." --#TYPE "Dell RAC Temperature Normal" --#SUMMARY "%s" --#ARGUMENTS {2} --#SEVERITY INFORMATIONAL --#CATEGORY Error Events ::= 1009 alertDrscTempWarning TRAP-TYPE ENTERPRISE drsOutofBandGroup VARIABLES { drsAlertSystem, drsAlertTableIndexOID, drsAlertMessage, drsAlertCurrentStatus, drsAlertPreviousStatus, drsAlertData } DESCRIPTION "The RAC Temperature probe has detected a Warning value." --#TYPE "Dell RAC Temperature Warning" --#SUMMARY "%s" --#ARGUMENTS {2} --#SEVERITY MINOR --#CATEGORY Error Events ::= 1010 alertDrscTempCritical TRAP-TYPE ENTERPRISE drsOutofBandGroup VARIABLES { drsAlertSystem, drsAlertTableIndexOID, drsAlertMessage, drsAlertCurrentStatus, drsAlertPreviousStatus, drsAlertData } DESCRIPTION "The RAC Temperature probe has detected a failure (or critical) value." --#TYPE "Dell RAC Temperature Failure" --#SUMMARY "%s" --#ARGUMENTS {2} --#SEVERITY CRITICAL --#CATEGORY Error Events ::= 1011 alertDrscVoltNormal TRAP-TYPE ENTERPRISE drsOutofBandGroup VARIABLES { drsAlertSystem, drsAlertTableIndexOID, drsAlertMessage, drsAlertCurrentStatus, drsAlertPreviousStatus, drsAlertData } DESCRIPTION "The RAC voltage has returned to a normal value." --#TYPE "Dell RAC Voltage Normal" --#SUMMARY "%s" --#ARGUMENTS {2} --#SEVERITY INFORMATIONAL --#CATEGORY Error Events ::= 1012 alertDrscVoltWarning TRAP-TYPE ENTERPRISE drsOutofBandGroup VARIABLES { drsAlertSystem, drsAlertTableIndexOID, drsAlertMessage, drsAlertCurrentStatus, drsAlertPreviousStatus, drsAlertData } DESCRIPTION "The RAC voltage probe has detected a warning value." --#TYPE "Dell RAC Battery Warning" --#SUMMARY "%s" --#ARGUMENTS {2} --#SEVERITY MINOR --#CATEGORY Error Events ::= 1013 alertDrscVoltCritical TRAP-TYPE ENTERPRISE drsOutofBandGroup VARIABLES { drsAlertSystem, drsAlertTableIndexOID, drsAlertMessage, drsAlertCurrentStatus, drsAlertPreviousStatus, drsAlertData } DESCRIPTION "The RAC voltage probe has detected a failure (or critical) value." --#TYPE "Dell RAC Voltage Failure" --#SUMMARY "%s" --#ARGUMENTS {2} --#SEVERITY CRITICAL --#CATEGORY Error Events ::= 1014 alertDrscSELWarning TRAP-TYPE ENTERPRISE drsOutofBandGroup VARIABLES { drsAlertSystem, drsAlertTableIndexOID, drsAlertMessage, drsAlertCurrentStatus, drsAlertPreviousStatus, drsAlertData } DESCRIPTION "The RAC has detected a new event in the System Event Log with Severity: Warning." --#TYPE "Dell RAC System Event Log Warning" --#SUMMARY "%s" --#ARGUMENTS {2} --#SEVERITY MAJOR --#CATEGORY Error Events ::= 1015 alertDrscSELCritical TRAP-TYPE ENTERPRISE drsOutofBandGroup VARIABLES { drsAlertSystem, drsAlertTableIndexOID, drsAlertMessage, drsAlertCurrentStatus, drsAlertPreviousStatus, drsAlertData } DESCRIPTION "The RAC has detected a new event in the System Event Log with Severity: Critical." --#TYPE "Dell RAC System Event Log Critical" --#SUMMARY "%s" --#ARGUMENTS {2} --#SEVERITY CRITICAL --#CATEGORY Error Events ::= 1016 alertDrscSEL80percentFull TRAP-TYPE ENTERPRISE drsOutofBandGroup VARIABLES { drsAlertSystem, drsAlertTableIndexOID, drsAlertMessage, drsAlertCurrentStatus, drsAlertPreviousStatus, drsAlertData } DESCRIPTION "The RAC has detected that the System Event Log is 80% full." --#TYPE "Dell System Event Log 80% Full Warning" --#SUMMARY "%s" --#ARGUMENTS {2} --#SEVERITY MAJOR --#CATEGORY Status Events ::= 1017 alertDrscSEL90percentFull TRAP-TYPE ENTERPRISE drsOutofBandGroup VARIABLES { drsAlertSystem, drsAlertTableIndexOID, drsAlertMessage, drsAlertCurrentStatus, drsAlertPreviousStatus, drsAlertData } DESCRIPTION "The RAC has detected that the System Event Log is 90% full." --#TYPE " Dell System Event Log 90% Full Warning " --#SUMMARY "%s" --#ARGUMENTS {2} --#SEVERITY MAJOR --#CATEGORY Status Events ::= 1018 alertDrscSEL100percentFull TRAP-TYPE ENTERPRISE drsOutofBandGroup VARIABLES { drsAlertSystem, drsAlertTableIndexOID, drsAlertMessage, drsAlertCurrentStatus, drsAlertPreviousStatus, drsAlertData } DESCRIPTION "The RAC has detected that the System Event Log is 100% full." --#TYPE " Dell System Event Log 100% Full Warning " --#SUMMARY "%s" --#ARGUMENTS {2} --#SEVERITY MAJOR --#CATEGORY Status Events ::= 1019 alertDrscSELNormal TRAP-TYPE ENTERPRISE drsOutofBandGroup VARIABLES { drsAlertSystem, drsAlertTableIndexOID, drsAlertMessage, drsAlertCurrentStatus, drsAlertPreviousStatus, drsAlertData } DESCRIPTION "The RAC has detected a new event in the System Event Log with Severity: Normal." --#TYPE "Dell RAC System Event Log Normal" --#SUMMARY "%s" --#ARGUMENTS {2} --#SEVERITY INFORMATIONAL --#CATEGORY Error Events ::= 1020 END