* Added more DELL switches in order to get proper CPU stats
More DELL switches supported:
* N4032
* N2048
* N2024
* N3048
* N2048P
* 54XX
* fixed indent as requested by phpcbf
* fixed multiline argument function call
* removed blank lines
* Added CPU stats for N4064F
* Added test data for N4064F
* fixed indent as requested by phpcbf
* Added test data for Dell Powerconnect 5424
* Added test data for Dell Powerconnect 5448
* Added test data for Dell Powerconnect 5524
* Added test data for Dell Powerconnect N4032
* Added test data for Dell Powerconnect N2024
* Added test data for Dell Powerconnect N2048
* Added test data for Dell Powerconnect N2048P
* Added test data for Dell Powerconnect N3048
* Fixed processor usage data
* Fixed snmpsim data for 3056
* Fixed processor usage
* easier to read format
* remove space changes
* 3056 should be 8%
* Fixed Junos port/vlan relationships for els and non-els based software
* fixed tabs
* Add test data
* Updated test data
* Update module_tables.yaml
* Update junos_qfx5100.json
* Update junos_qfx5100.json
* Update junos_qfx5100.json
* Update opengear MIBs to latest version.
* Replace PHP signal discovery with YAML.
* Update Opengear YAML with new sensors.
* Add test data for Opengear.
* Add the test data json for Opengear.
* Named to numbered index to avoid data loss.
* Simple linear port graph prediction
Simple linear prediction line for in and out if graph "to" value is in the future
Improve graph date handling
* thinner line
* Make test specify timezone
* Laravel 5.8
and dependencies
* Fix cache time
* upstream base file changes
* Accidentally ran composer with PHP 7.3
* fix test error
* one more
* one more
* one more
* fix dotenv loading
* Add more api helper functions
to centralize code more
* Enable cors
* Initial Legacy route in Laravel
* Force api v0 responses to json
Add a couple more routes
* more paths, pretty print the json response
pass parameters to the api function
* devices basic functions
* Port generic graph function
check permissions function accepts callback to avoid lots of if statements
* move vlans
* links
* graphs
* fdb
* health
* wireless
* port graphs
* ip functions
split em up
* port_stack
* components
* compoment add/edit/delete
* get_device_groups
* port stats
* port graphs
* get_devices_by_group
* port_groups
* api_get_graph
* show_endpoints
* get_bill
* get_bill_graph
* get_bill_graphdata
* get_bill_history
* get_bill_history_graph
* remaining bill functions
* list_alerts
* ack/unmute alert
* Some cleanups
* Some cleanups
* list_alert_rules
* alert rule add/edit/delete
* inventory
* list_cbgp
* vrf
* list_ipsec
* list_fdb
* list_links (fix both usages)
* list_locations
* list_locations
* list_vlans
* list_ip_addresses
* list_arp
* list_ip_networks
* cleanup
* services
* list_logs and fix authlog.......
* cleanup
* cleanup 2
* remove slim
* don't load schema more than once
* basic test
* fix style
* downgrade laravel-cors to a version that supports PHP 7.1
* initial database migrations
* first part, discovery
* second part, polling
* add SAP polling and discovery
* style checks
* rename variables in more generic way
* html global pages for sdp and sdp binds
* add Services and SAPs
* port links, database, etc.
* html device routing pages
* add tests
* checks
* rework database id relationship
* scruntinizer inspection
* fix unit test for new mpls tables
* Update MRV MIBs to version 5.14.1
* Learn SlotTemperature limits from the new MIB.
* Rename MIB files to the name of the MIB.
* Update mrv-od.snmprec
* Update mrv-od.json
* Added support for snmp monitored PDU from fs.com
* Added support for snmp monitored PDU from fs.com
* Fix sysObjectID 1.3.6.1.4.1.30966
* Create fs-net-pdu.json
* Add phase2 name to IPSEC sensor.
For VPN tunnels with more than one phase2, the sensor is confusing.
Using the phase2 value provides both the phase1 and phase2 name for a more complete sensor.
* Update fortigate.yaml
phase1\phase2 naming for a more clear sensor.
test data to come
* add test data
* more test data?
* missing whitespace compared to original
* Remove wireless data
* Added support for DGD and BER that are avalible on newer infinera-groove FW
* updated tests for new groove sensors
* Update infinera-groove.inc.php
* Update infinera-groove.inc.php
* Force test to run again
* Default to null for group yaml discovery.
* Update test data for a154bda yaml group null fix.
* Changes to guessed limit functions for sensors.
Original behaviour
===================
The file `includes/discovery/functions.inc.php` contains
`sensor_limit_low()` and `sensor_limit()` which both attempt to
guess a sane value for sensors when no explicitly defined
low_limit or high_limit can be found during discovery.
Both switch control structures used in those two functions
have empty case statements which means that if one of those matches,
it's going to fall through and run the code for each subsequent
case until a `break` is reached.
For example, when we call `function sensor_low_limit(dbm, -13.036)`
it will return the value `-12.3842` instead of `null`. That is
because there will be a match at `case 'dbm':` which falls through
all the way to `case 'cooling':`, where it performs
`$limit = -13.036 * 0.95` before hitting a `break`.
Changed behaviour
===================
Removed `power_consumed` and `count` guessed low_limit and
high_limit, I personally added those sensor classes in PR #9471
when I didn't understand that a switch control structure has
fall-through behaviour so I can guarantee that guessing limits for
those is a mistake on my behalf. It should not be there, only
power_factor can have guessed limits. Apologies for the issue,
I'm still a beginning programmer!
Furthermore, I removed guessed high_limit values for `current`
and `power` because these are supposed to draw higher values as
more devices or components are installed on for example a PDU or
a chassis.
Finally, I removed guessed low_limit and high_limit for `dbm`
sensors, there is a much too large variance in power budget on
commercially available optical transceivers for there to be a
sensible window where you can guess these values.
* Documentation on adding sensor classes.
* Update test data - sensor limit changes @ 30212d2
* Device Groups rewrite
Updated web ui
Static or dynamic groups allowed
Alert rule query builder
Translation support
Permissions support
* cleanup, make relationship save, and validate it
* builder WIP
* rules builder and rules saving/loading
* Parse query builder to Laravel Fluent query
* Upgrade existing groups when editing.
Properly update only dynamic groups when polling.
* remove unused old code
Update API and other places to use Eloquent
* debug output in poller restored
* Fix up some things
creating static
improved validation
fix js error on creation
Fix static groups in polling
* hide pattern for static group
* Implement authorization
Use in the menu too
* update schema
* fix rollback
* Don't abort on invalid queries
* fixes to query builder
* add test data, looks like macros aren't handled (omitted them because groups don't use them generally)
* Add macro support for QueryBuilderFluentParser
* add test for macro that accepts value
* More space in forms
Retain rules when converted to static
no duplicate names allowed
* Better error feedback
Update related devices on save
* Add button icon
* format
* update docs
* fix tests
* Fix some QueryBuilderFluentParser issues with OR
updated/more test data
* Show device groups runtime
fix querybuilder.json format
* Store table joins in the rules to minimize polling time
Update group joins in daily.sh (and when they are saved)
* Update daily.php
* Add units to time
* Device Groups rewrite
Updated web ui
Static or dynamic groups allowed
Alert rule query builder
Translation support
Permissions support
* cleanup, make relationship save, and validate it
* builder WIP
* rules builder and rules saving/loading
* Parse query builder to Laravel Fluent query
* Upgrade existing groups when editing.
Properly update only dynamic groups when polling.
* remove unused old code
Update API and other places to use Eloquent
* debug output in poller restored
* Fix up some things
creating static
improved validation
fix js error on creation
Fix static groups in polling
* hide pattern for static group
* Implement authorization
Use in the menu too
* update schema
* fix rollback
* Don't abort on invalid queries
* fixes to query builder
* add test data, looks like macros aren't handled (omitted them because groups don't use them generally)
* Add macro support for QueryBuilderFluentParser
* add test for macro that accepts value
* More space in forms
Retain rules when converted to static
no duplicate names allowed
* Better error feedback
Update related devices on save
* Add button icon
* format
* update docs
* fix tests
* Aruba IAP: Fix Radio State Sensor
Fix state sensor for radio status from warning when disabled to unknown state.
* Update aruba-instant.json
* Update aruba-instant_105.json
* Fix Software Version #
I don't think setting $firmware does anything, not to mention the regex wasn't matching correctly. I tested this fix tons of different software versions and they all seem to work.
* Revert "OS CIMC Software Version Number"
* version and features
* fixed feature
* Fix Extra Blank line EOF
* Extend the Dell drac module to report CMC status and sensors
* CMC status sensors do not have chassis id
* Update test data for drac OS
* Add missing test data for drac os
* WIP - Add MPLS Support
This introduce the generic MPLS support
- New database tables for MPLS LSPs
- actually discovery and polling on NOKIA SR OS (Timetra) devices
- new routing->MPLS HTML pages
- ToDo MPLS LSP paths table and views
Suggestions and improvements are welcome
* add db schema
* some fixes
* add path table, discovery and polling
* add path views
* add test data
* Convert MPLS module to new style
Implement a SyncsModels trait to simplify code a lot
* abs() for negative value from snmp (bug?), test data
* fix db schema
* Fix up test data, remove uneeded data in json
* fix whitespace
* Fix Software Version #
I don't think setting $firmware does anything, not to mention the regex wasn't matching correctly. I tested this fix tons of different software versions and they all seem to work.
* Revert "OS CIMC Software Version Number"
* cimc-version-fix
* added test data
* Update cimc.snmprec
* Dynamic entPhysicalIndex values for YamlDiscovery
* Use degree symbol when displaying temperature values
* Adjust SNMP options for new snmp_get_multi()
The OS polling module for mrv-od was using snmpget commands with
-Ovqs, rather than -OQUs, which meant that the equal sign was
stripped in the snmpget output. But that equal sign is now used
as the explode() delimiter so it broke the construction of the
returned array for the snmp_get_multi() function.
Additionally, I removed the NBS-CMMC-MIB:: prefix which is no
longer returned by snmp_get_multi() as part of the OID. Now,
the mrv-od.inc.php OS polling module is retrieving data from
positions in the array with actual content.
* Convert mrv-od to yaml, improve sensors discovery
Converted sensors discovery for mrv-od to yaml, retaining all
functionality for pre-cache, dbm, and temperature. Replaced specific
SFF-8472 Digital Diagnostics state sensors with generic ones, given that
we are now reading out detailed values through new dbm, current, voltage
sensors.
Reasoning: the generic Digital Diagnostics state sensors report state
diagsOk, or else the worst severity level measured among all of the
Digital Diagnostics values for that optical data point. You'd really
only want to set a generic "alarm" so the box can report that it
thinks something is wrong, whereafter a human can look at the graphs
and/or the CLI to draw their conclusions about the alarm. Otherwise,
things would quickly become too spammy as you are essentially duplicating
every sensor across both regular measurements and state measurements.
Further changes:
- Increase maximum number of detected PSUs from 4 to 8 per the MIB.
- State sensor to detect (in)sufficient power budget for all modules.
- Use skip_values to hide state sensors with the notSupported value.
- Use skip_values to hide sensors which are unsupported per the MIB,
signified by the device returning special values -1 or -2147483648.
- Add dBm, temperature "over" graphs to the mrv-od device header bar.
* Add mrv-od entity-physical support
MRV does not use the ENTITY-MIB data format, so we had to reconstruct
the inventory from their proprietary format using the following tables
from their NBS-CMMC-MIB:
- nbsCmmcChassisTable
- nbsCmmcSlotTable
- nbsCmmcPortTable
Additionally, since sensors didn't have their own ifindex in the
NBS-CMMC-MIB, I went ahead and appended the last OID digit to
the "containing" ifindex create a unique number. The same was
done for the sensors in the yaml-discovery.
* Test data for mrv-od, fix 2* pre-commit.php issues
* Fix entPhysicalIndex returning 0 instead of null
Some unit test breakage was caused by 62167ebcb which changed
the code to return 0 instead of null when {{ $index }} was
set as the entPhysicalIndex in the YamlDiscovery. So now we
detect if it returns some value which may be interpreted as
false, and if so we set null rather than 0.