* Add support for FiberStore "data center" switches
FiberStore has two different model lines of switches, and this adds
support for the "data center" line. This was configured and tested
against the N5860-48SC model.
The MIBs are from FiberStore's website, with the exception of the
FS-FIBER-MIB (the website version is a little behind the software, so
support sent me an updated version and should be getting it published
soon).
This does not currently handle 4x10 or 4x25 QSFP+ light levels, as I
don't currently have any to test against.
* Add test data for fs-switch-dc
This is from a production switch, with data filtered to just the
FiberStore enterprises OID.
* Update fs-switch-dc_fs-switch-dc.json
* correct processors warn field name
* Update fs-switch-dc_fs-switch-dc.json
* Update fs-switch-dc.yaml
---------
Co-authored-by: Tony Murray <murraytony@gmail.com>
* FS OAP OEO and EDFA mibs
* definitions and discovery yaml
* current dbm state temperature and voltage updates
* update on poller and discovery modules
* test data
* removing unneeded pollers and discovery modules as requested
* update to os test data
test data now reflects fs-nmu details instead of module details as module may not be present at previous oid or module may not be present at all in the device
* OS update and Test Date Updates
* channels numbers
* removal of default true poller and discovery modules
* reintroduced previous OEO module data
* StyleCI fixes
* Update fs-nmu.inc.php
* Update fs-nmu.inc.php
* Update fs-nmu.inc.php
* Update fs-nmu.inc.php
* Update fs-nmu.inc.php
Co-authored-by: Neil Lathwood <gh+n@laf.io>
* extend FS switches support
* MIB compilation
* HW and Ver
* sensors and CPU
* tests
* correct version
* try to handle properly "down" as not up, for OperStat like lowerLayerDown
* try to handle properly "down" as not up, for OperStat like lowerLayerDown
* try to handle properly "down" as not up, for OperStat like lowerLayerDown
* try to replace "down" with "not up" :)
* fix other ifOperStatus checks