From df7b72afaec91683e4418966f4b94c4f7933f9ac Mon Sep 17 00:00:00 2001 From: Steven Barnes Date: Mon, 23 Apr 2018 14:46:47 -0500 Subject: [PATCH] Update PDU2-MIB (#8475) Also - it appears that some sensors for these Raritan PDUs still want to pull the MIB out of `/opt/librenms/mib` instead of the raritan folder. Also this MIB adds humidity sensors. --- mibs/raritan/PDU2-MIB | 20869 ++++++++++++++++++++++------------------ 1 file changed, 11297 insertions(+), 9572 deletions(-) diff --git a/mibs/raritan/PDU2-MIB b/mibs/raritan/PDU2-MIB index 74211703ea..415c687d5b 100644 --- a/mibs/raritan/PDU2-MIB +++ b/mibs/raritan/PDU2-MIB @@ -8,10825 +8,12550 @@ IMPORTS InetAddressType, InetAddress, InetPortNumber FROM INET-ADDRESS-MIB sysContact, sysName, sysLocation FROM RFC1213-MIB; - raritan MODULE-IDENTITY - LAST-UPDATED "201406040000Z" -- June 04, 2014 + LAST-UPDATED "201711130000Z" -- November 13, 2017 ORGANIZATION "Raritan" - CONTACT-INFO " - Author: Raritan Americas, Inc. - postal: Raritan Americas, Inc. - 400 Cottontail Lane - Somerset, NJ 08873 - email: tech@raritan.com - phone: +1 732 764 8886 - " - DESCRIPTION "This MIB describes the SNMP functions of the Dominion PX G2 - Power Distribution Unit by Raritan Computer." + CONTACT-INFO + "Author: Raritan Americas, Inc. + postal: Raritan Americas, Inc. + 400 Cottontail Lane + Somerset, NJ 08873 + email: tech@raritan.com + phone: +1 732 764 8886" + DESCRIPTION + "This MIB describes the SNMP functions of the Raritan PX2, PX3 + and BCM2 series power distribution units by Raritan." + + REVISION "201711130000Z" -- November 13, 2017 + DESCRIPTION + "PX2/PX3 release 3.4.0: + 1) Changed STATUS of inletConfigurationTable/inletRCMResidualOperatingCurrent to obsolete + 2) Added to trapInformationGroup: + smartCardReaderId + smartCardTimestamp + smartCardType + smartCardId + suspectedTripCauseLabel + 3) Added the following traps: + smartCardInserted + smartCardRemoved + 4) Deprecated the following traps: + rfCodeTagConnected + rfCodeTagDisconnected + 5) Revised the DESCRIPTION of all objects + 6) SensorTypeEnumeration: Added + doorLockState(49) + doorHandleLock(50) + 7) Added to overCurrentProtectorSensorStateChange trap: + suspectedTripCauseLabel" + + REVISION "201612020000Z" -- December 2, 2016 + DESCRIPTION + "PX2/PX3 release 3.3.10: + 1) Added 'none(2)' to DeviceCascadeTypeEnumeration + 2) Deprecated unitConfigurationTable/pxMACAddress + 3) Deprecated unitConfigurationTable/networkInterfaceType + 4) Added pduSerialNumber to the OBJECTS clause of all traps + 5) Deprecated activeDNSServerTable/activeDNSServerAddressSource + 6) Deprecated activeNTPServerTable/activeNTPServerAddressSource + 7) Changed STATUS of unitConfigurationTable/useDHCPProvidedNTPServer to obsolete + 8) Added OBJECT-GROUP obsoleteObjectsGroup + 9) Modified DESCRPTION of the following: + deviceCascadeType + deviceCascadePosition + outletPowerCyclingPowerOffPeriod + pduPowerCyclingPowerOffPeriod + globalOutletPowerCyclingPowerOffPeriod + usbSlaveConnected + usbSlaveDisconnected" + + REVISION "201602160000Z" -- February 16, 2016 + DESCRIPTION + "PX2/PX3 release 3.3.0: + 1) Added inletRatedCurrent to the following traps: + powerMeterModified + powerMeterAdded + 2) Added activeNTPServerCount to unitConfigurationTable + 3) Added activeNTPServerTable" + + REVISION "201602090000Z" -- February 9, 2016 + DESCRIPTION + "PX2/PX3 release 3.2.20: + 1) Added the following: + NetworkInterfaceTypeEnumeration, + networkInterfaceType to unitConfigurationTable + 2) Added AddressSourceEnumeration + 3) Added activeDNS ServerCount to unitConfigurationTable + 4) Added activeDNSServerTable" + + REVISION "201510260000Z" -- October 26, 2015 + DESCRIPTION + "PX2/PX3 release 3.2.10: + 1) Added to trapInformation: + phoneNumber + 2) Added the following traps: + smsMessageTransmissionFailure trap" + + REVISION "201509300000Z" -- September 30, 2015 + DESCRIPTION + "PX2/PX3 release 3.2.1: + - Support for PMC/BCM2 + - Line and node information for component poles + + 1) SensorTypeEnumeration: Added + reactivePower(29) + displacementPowerFactor(35) + 2) SensorUnitsEnumeration: Added + var(23) + 3) ProductTypeEnumeration: Added + powerMeter(3) + 4) Added the following enumerations: + PanelLayoutEnumeration + PanelNumberingEnumeration + CircuitTypeEnumeration + PhaseEnumeration + LineEnumeration + PowerMeterTypeEnumeration + 5) Added the following tables: + inletPoleConfigurationTable + overCurrentProtectorPoleConfigurationTable + outletPoleConfigurationTable + transferSwitchPoleConfigurationTable + powerMeterConfigurationTable + circuitConfigurationTable + circuitPoleConfigurationTable + circuitSensorConfigurationTable + circuitPoleSensorConfigurationTable + circuitSensorLogTable + circuitPoleSensorLogTable + circuitSensorMeasurementsTable + circuitPoleSensorMeasurementsTable + circuitSensorControlTable + 6) unitConfigurationTable: Added + circuitCount + 7) inletDeviceCapabilities: Added + reactivePower(28) + 8) inletPoleCapabilities: Added + phaseAngle(23) + reactivePower(28) + displacementPowerFactor(34) + 9) overCurrentProtectorConfigurationTable: Added + overCurrentProtectorPoleCount + 10) transferSwitchConfigurationTable: Added + transferSwitchPoleCount + 11) Added the following to trapInformation: + circuitNumber + circuitPoleNumber + 12) Added the following traps: + circuitSensorStateChange + circuitPoleSensorStateChange + circuitAdded + circuitDeleted + circuitModified + circuitSensorReset + powerMeterAdded + powerMeterDeleted + powerMeterModified + 13) Revised the DESCRIPTION clauses of: + pduCount + pduId + inletPoleCount" + + REVISION "201502180000Z" -- February 18, 2015 + DESCRIPTION + "PX2/PX3 release 3.1.0: + - Support absolute humidity sensors + + 1) SensorStateEnumeration: Added + nonRedundant(30) + 2) SensorTypeEnumeration: Added + absoluteHumidity(28) + 3) SensorUnitsEnumeration: Added + grampercubicmeter(22) + 4) Corrected the possible states for the rcmState, operatingState and activeInlet sensors + 5) Documented that the unitSensorResetValue object in unitSensorControlTable applies + only to multi-inlet PDUs + 6) Deprecated inletRatedVA, inletRatedFrequency + 7) inletDeviceCapabilities: Corrected bit values for residualCurrent(25) + and rcmState(26)" REVISION "201406040000Z" -- June 04, 2014 + DESCRIPTION + "PX2/PX3 release 3.0.0: + - Support for signed sensor readings + - Support for unit-level power and energy sensors + - Send trap on peripheral device firmware update + - Allow peripheral device auto management to be disabled + - Allow front panel outlet switching to be enabled or disabled + - Support DX-PIR occupancy sensor - DESCRIPTION "PX2 release 3.0.0: - - Support for signed sensor readings - - Support for unit-level power and energy sensors - - Send trap on peripheral device firmware update - - Allow peripheral device auto management to be disabled - - Allow front panel outlet switching to be enabled or disabled - - Support DX-PIR occupancy sensor - - 1) Changed the SYNTAX from Integer32 to Unsigned32: - measurementsUnitSensorValue - 2) Added signed value, range and threshold columns to: - unitSensorConfigurationTable - unitSensorMeasurementsTable - pduSensorStateChange - inletSensorConfigurationTable - inletSensorMeasurementsTable - inletSensorLogTable - inletSensorStateChange - inletPoleSensorConfigurationTable - inletPoleSensorMeasurementsTable - inletPoleSensorLogTable - inletPoleSensorStateChange - overCurrentProtectorSensorConfigurationTable - overCurrentProtectorSensorMeasurementsTable - overCurrentProtectorSensorLogTable - overCurrentProtectorSensorStateChange - outletSensorConfigurationTable - outletSensorMeasurementsTable - outletSensorLogTable - outletSensorStateChange - outletPoleSensorConfigurationTable - outletPoleSensorMeasurementsTable - outletPoleSensorLogTable - outletPoleSensorStateChange - 3) Added unsigned value, range and threshold columns to: - unitSensorLogTable - transferSwitchSensorConfigurationTable - transferSwitchSensorMeasurementsTable - transferSwitchSensorLogTable - transferSwitchSensorStateChange - 4) Added UnitSensorControlTable - 5) Added unitSensorReset and unitSensorStateChange traps - 6) Deprecated pduSensorStateChange trap - 7) Added to unitConfigurationTable: - peripheralDevicesAutoManagement - frontPanelOutletSwitching - frontPanelRCMSelfTest - frontPanelActuatorControl - 8) Added to externalSensorConfigurationTable: - externalSensorAlarmedToNormalDelay - 9) Deprecated: - wireCount in unitConfiguraionTable - tables for wireSensors - traps for wireSensors - 10) SensorStateEnumeration: Added - fail(14) - 11) ProductTypeEnumeration: Renamed - rackSts(2) to transferSwitch - 12) Added: - PeripheralDeviceFirmwareUpdateStateEnumeration - peripheralDeviceFirmwareUpdateState - peripheralDeviceFirmwareUpdate trap - 13) Added userName to the following traps: - bulkConfigurationSaved - bulkConfigurationCopied - lhxSupportChanged - deviceSettingsSaved - deviceSettingsRestored - " - + 1) Changed the SYNTAX from Integer32 to Unsigned32: + measurementsUnitSensorValue + 2) Added signed value, range and threshold columns to: + unitSensorConfigurationTable + unitSensorMeasurementsTable + pduSensorStateChange + inletSensorConfigurationTable + inletSensorMeasurementsTable + inletSensorLogTable + inletSensorStateChange + inletPoleSensorConfigurationTable + inletPoleSensorMeasurementsTable + inletPoleSensorLogTable + inletPoleSensorStateChange + overCurrentProtectorSensorConfigurationTable + overCurrentProtectorSensorMeasurementsTable + overCurrentProtectorSensorLogTable + overCurrentProtectorSensorStateChange + outletSensorConfigurationTable + outletSensorMeasurementsTable + outletSensorLogTable + outletSensorStateChange + outletPoleSensorConfigurationTable + outletPoleSensorMeasurementsTable + outletPoleSensorLogTable + outletPoleSensorStateChange + 3) Added unsigned value, range and threshold columns to: + unitSensorLogTable + transferSwitchSensorConfigurationTable + transferSwitchSensorMeasurementsTable + transferSwitchSensorLogTable + transferSwitchSensorStateChange + 4) Added UnitSensorControlTable + 5) Added unitSensorReset and unitSensorStateChange traps + 6) Deprecated pduSensorStateChange trap + 7) Added to unitConfigurationTable: + peripheralDevicesAutoManagement + frontPanelOutletSwitching + frontPanelRCMSelfTest + frontPanelActuatorControl + 8) Added to externalSensorConfigurationTable: + externalSensorAlarmedToNormalDelay + 9) Deprecated: + wireCount in unitConfiguraionTable + tables for wireSensors + traps for wireSensors + 10) SensorStateEnumeration: Added + fail(14) + 11) ProductTypeEnumeration: Renamed + rackSts(2) to transferSwitch + 12) Added: + PeripheralDeviceFirmwareUpdateStateEnumeration + peripheralDeviceFirmwareUpdateState + peripheralDeviceFirmwareUpdate trap + 13) Added userName to the following traps: + bulkConfigurationSaved + bulkConfigurationCopied + lhxSupportChanged + deviceSettingsSaved + deviceSettingsRestored" REVISION "201401090000Z" -- January 9, 2014 + DESCRIPTION + "PX2/PX3 release 2.6.0: + - Support for PX3TS transfer switches - DESCRIPTION "PX2 release 2.6.0: - - Support for PX3TS transfer switches - - 1) SensorTypeEnumeration: - Removed: - scrOpenStatus - scrShortStatus - Added: - i1SmpsStatus(46) - i2SmpsStatus(47) - switchStatus(48) - 2) SensorStateEnumeration: - Removed: - marginal - fail - Added: - i1OpenFault(22) - i1ShortFault(23) - i2OpenFault(24) - i2ShortFault(25) - fault(26) - warning(27) - critical(28) - 3) unitDeviceCapabilities: Added - i1SmpsStatus(45) - i2SmpsStatus(46) - 4) transferSwitchCapabilities: Added - switchStatus(47) - 5) Added transferSwitchConfiguration table - 6) unitSensorLogTable: - Removed: - logUnitSensorAvgValue - logUnitSensorMaxValue - logUnitSensorMinValue - Added: - logUnitSensorSignedAvgValue - logUnitSensorSignedMaxValue - logUnitSensorSignedMinValue - " - + 1) SensorTypeEnumeration: + Removed: + scrOpenStatus + scrShortStatus + Added: + i1SmpsStatus(46) + i2SmpsStatus(47) + switchStatus(48) + 2) SensorStateEnumeration: + Removed: + marginal + fail + Added: + i1OpenFault(22) + i1ShortFault(23) + i2OpenFault(24) + i2ShortFault(25) + fault(26) + warning(27) + critical(28) + 3) unitDeviceCapabilities: Added + i1SmpsStatus(45) + i2SmpsStatus(46) + 4) transferSwitchCapabilities: Added + switchStatus(47) + 5) Added transferSwitchConfiguration table + 6) unitSensorLogTable: + Removed: + logUnitSensorAvgValue + logUnitSensorMaxValue + logUnitSensorMinValue + Added: + logUnitSensorSignedAvgValue + logUnitSensorSignedMaxValue + logUnitSensorSignedMinValue" REVISION "201401070000Z" -- January 7, 2014 + DESCRIPTION + "PX2/PX3 release 2.5.30: + - Accumulating sensors (energy counters) can be reset + - Sensor accuray and tolerance variables are deprecated - DESCRIPTION "PX2 release 2.5.30: - - Accumulating sensors (energy counters) can be reset - - Sensor accuray and tolerance variables are deprecated - - 1) Added peripheralDevicePackagePosition and peripheralDevicePackageState - 2) Added radiusError trap - 3) Added serverReachabilityError trap - 4) Deprecated the following: - unitSensorConfigurationTable/unitSensorAccuracy - unitSensorConfigurationTable/unitSensorTolerance - inletSensorConfigurationTable/inletSensorAccuracy - inletSensorConfigurationTable/inletSensorTolerance - inletPoleSensorConfigurationTable/inletPoleSensorAccuracy - inletPoleSensorConfigurationTable/inletPoleSensorTolerance - outletSensorConfigurationTable/outetSensorAccuracy - outletSensorConfigurationTable/outletSensorTolerance - outletPoleSensorConfigurationTable/outetPoleSensorAccuracy - outletPoleSensorConfigurationTable/outletPoleSensorTolerance - overCurrentProtectorSensorConfigurationTable/overCurrentProtectorSensorAccuracy - overCurrentProtectorSensorConfigurationTable/overCurrentProtectorSensorTolerance - externalSensorConfigurationTable/externalSensorAccuracy - externalSensorConfigurationTable/externalSensorTolerance - wireSensorConfigurationTable/wireSensorAccuracy - wireSensorConfigurationTable/wireSensorTolerance - transferSwitchSensorConfigurationTable/transferSwitchSensorAccuracy - transferSwitchSensorConfigurationTable/transferSwitchSensorTolerance - 5) Added inletSensorReset and outletSensorReset traps - 6) Added inletSensorControl and inletSensorControlTable - 7) Added outletSensorControl and outletSensorControlTable - 8) Added unknownPeripheralDeviceAttached trap - " - + 1) Added peripheralDevicePackagePosition and peripheralDevicePackageState + 2) Added radiusError trap + 3) Added serverReachabilityError trap + 4) Deprecated the following: + unitSensorConfigurationTable/unitSensorAccuracy + unitSensorConfigurationTable/unitSensorTolerance + inletSensorConfigurationTable/inletSensorAccuracy + inletSensorConfigurationTable/inletSensorTolerance + inletPoleSensorConfigurationTable/inletPoleSensorAccuracy + inletPoleSensorConfigurationTable/inletPoleSensorTolerance + outletSensorConfigurationTable/outetSensorAccuracy + outletSensorConfigurationTable/outletSensorTolerance + outletPoleSensorConfigurationTable/outetPoleSensorAccuracy + outletPoleSensorConfigurationTable/outletPoleSensorTolerance + overCurrentProtectorSensorConfigurationTable/overCurrentProtectorSensorAccuracy + overCurrentProtectorSensorConfigurationTable/overCurrentProtectorSensorTolerance + externalSensorConfigurationTable/externalSensorAccuracy + externalSensorConfigurationTable/externalSensorTolerance + wireSensorConfigurationTable/wireSensorAccuracy + wireSensorConfigurationTable/wireSensorTolerance + transferSwitchSensorConfigurationTable/transferSwitchSensorAccuracy + transferSwitchSensorConfigurationTable/transferSwitchSensorTolerance + 5) Added inletSensorReset and outletSensorReset traps + 6) Added inletSensorControl and inletSensorControlTable + 7) Added outletSensorControl and outletSensorControlTable + 8) Added unknownPeripheralDeviceAttached trap" REVISION "201311210000Z" -- November 21, 2013 + DESCRIPTION + "PX2/PX3 release 2.5.20: + - Support for residual current monitors + - Support for USB cascading with one IP address + - Support for line-neutral voltage sensors - DESCRIPTION "PX2 release 2.5.20: - - Support for residual current monitors - - Support for USB cascading with one IP address - - Support for line-neutral voltage sensors - - 1) SensorTypeEnumeration: Added - rmsVoltageLN(25) - residualCurrent(26) - rcmState(27) - 2) SensorStateEnumeration: Added - warning(27) - critical(28) - selfTest(29) - 3) inletDeviceCapabilities: Added - residualCurrent(26) - rcmState(27) - 4) Added rmsVoltageLN(24) to inletPoleCapabilities - 5) Added inletRCMResidualOperatingCurrent to inletConfigurationTable - 6) Added rcmControl under control - 7) Added rcmSelfTestTable under rcmControl - 8) Added DeviceCascadeTypeEnumeration - 9) Added deviceCascadeType, deviceCascadePosition to unitConfigurationTable - 10) Added agentInetPortNumber under trapInformation - 11) Added agentInetPortNumber as a varbind to all traps - 12) Added peripheralDevicePackageTable containing information on peripheral - device packages - " - + 1) SensorTypeEnumeration: Added + rmsVoltageLN(25) + residualCurrent(26) + rcmState(27) + 2) SensorStateEnumeration: Added + warning(27) + critical(28) + selfTest(29) + 3) inletDeviceCapabilities: Added + residualCurrent(26) + rcmState(27) + 4) Added rmsVoltageLN(24) to inletPoleCapabilities + 5) Added inletRCMResidualOperatingCurrent to inletConfigurationTable + 6) Added rcmControl under control + 7) Added rcmSelfTestTable under rcmControl + 8) Added DeviceCascadeTypeEnumeration + 9) Added deviceCascadeType, deviceCascadePosition to unitConfigurationTable + 10) Added agentInetPortNumber under trapInformation + 11) Added agentInetPortNumber as a varbind to all traps + 12) Added peripheralDevicePackageTable containing information on peripheral + device packages" REVISION "201309180000Z" -- September 18, 2013 - - DESCRIPTION " - 1) Added serverConnectivityUnrecoverable trap - - " - + DESCRIPTION + "1) Added serverConnectivityUnrecoverable trap" REVISION "201308010000Z" -- August 1, 2013 - - DESCRIPTION " - 1) Add RCBO OCP types - - " + DESCRIPTION + "1) Added RCBO OCP types" REVISION "201307100000Z" -- July 10, 2013 - - DESCRIPTION " - 1) Added externalSensorTypeDefaultThresholdsTable - - " - + DESCRIPTION + "1) Added externalSensorTypeDefaultThresholdsTable" REVISION "201307020000Z" -- July 2, 2013 - - DESCRIPTION " - 1) Added relayBehaviorOnPowerLoss to unitConfigurationTable - " - + DESCRIPTION + "1) Added relayBehaviorOnPowerLoss to unitConfigurationTable" REVISION "201305210000Z" -- May 21, 2013 - - DESCRIPTION " - 1) Added inletEnableState to inletConfigurationTable - 2) Added traps: inletEnabled and inletDisabled - " - + DESCRIPTION + "1) Added inletEnableState to inletConfigurationTable + 2) Added traps: inletEnabled and inletDisabled" REVISION "201304260000Z" -- April 26, 2013 - - DESCRIPTION " - 1) Added traps: webcamInserted and webcamRemoved - 2) Added trapInformation parameters: webcamModel,webcamConnectionPort - - " - + DESCRIPTION + "1) Added traps: webcamInserted and webcamRemoved + 2) Added trapInformation parameters: webcamModel, webcamConnectionPort" REVISION "201303270000Z" -- March 27, 2013 - - DESCRIPTION " - 1) Changed outletSource to outletPowerSource in outletConfigurationTable - 2) Changed transferSwitchSource1 and transferSwitchSource2 to - transferSwitchPowerSource1 and transferSwitchPowerSource2 in transferSwitchConfigurationTable - 3) Changed overCurrentProtectorSource to overCurrentProtectorPowerSource in overCurrentProtectorConfigurationTable - 4) Changed wireSource to wirePowerSource in wireConfigurationTable - - " + DESCRIPTION + "1) Changed outletSource to outletPowerSource in outletConfigurationTable + 2) Changed transferSwitchSource1 and transferSwitchSource2 to + transferSwitchPowerSource1 and transferSwitchPowerSource2 in transferSwitchConfigurationTable + 3) Changed overCurrentProtectorSource to overCurrentProtectorPowerSource in overCurrentProtectorConfigurationTable + 4) Changed wireSource to wirePowerSource in wireConfigurationTable" REVISION "201303251000Z" -- March 25, 2013 - - DESCRIPTION " - 1) Added comments showing the possible states for each sensor type. - " - + DESCRIPTION + "1) Added comments showing the possible states for each sensor type." REVISION "201303250000Z" -- March 25, 2013 - - DESCRIPTION " - 1) Added outletSource to outletConfigurationTable - 2) Added transferSwitchSource1 and transferSwitchSource2 to transferSwitchConfigurationTable - 3) Added overCurrentProtectorSource to overCurrentProtectorConfigurationTable - 4) Added wireSource to wireConfigurationTable - - " - + DESCRIPTION + "1) Added outletSource to outletConfigurationTable + 2) Added transferSwitchSource1 and transferSwitchSource2 to transferSwitchConfigurationTable + 3) Added overCurrentProtectorSource to overCurrentProtectorConfigurationTable + 4) Added wireSource to wireConfigurationTable" REVISION "201303180000Z" -- March 18, 2013 - - DESCRIPTION " 1) Added meteringControllerCount to the unitConfigurationTable - 2) Added meteringController to BoardTypeEnumeration - " - + DESCRIPTION + "1) Added meteringControllerCount to the unitConfigurationTable + 2) Added meteringController to BoardTypeEnumeration" REVISION "201302250000Z" -- February 25, 2013 - - DESCRIPTION " - 1) Added ProductTypeEnumeration - 2) Added productType to unitConfigurationTable - " + DESCRIPTION + "1) Added ProductTypeEnumeration + 2) Added productType to unitConfigurationTable" REVISION "201302040000Z" -- February 04, 2013 - - DESCRIPTION " 1) Added TransferSwitchTransferReasonEnumeration - 2) Added transferSwitchLastTransferReason to transferSwitchControlTable - 3) Added transferSwitchLastTransferReason to transferSwitchSensorStateChange trap - " - + DESCRIPTION + "1) Added TransferSwitchTransferReasonEnumeration + 2) Added transferSwitchLastTransferReason to transferSwitchControlTable + 3) Added transferSwitchLastTransferReason to transferSwitchSensorStateChange trap" REVISION "201301240000Z" -- January 24, 2013 - - DESCRIPTION "Added required sensor types and units - " + DESCRIPTION + "1) Added required sensor types and units" REVISION "201211200000Z" -- November 20, 2012 - - DESCRIPTION "1) Added externalSensorIsActuator and externalSensorPosition to the externalSensorConfigurationTable - 2) Added actuatorControlTable - " - + DESCRIPTION + "1) Added externalSensorIsActuator and externalSensorPosition to the externalSensorConfigurationTable + 2) Added actuatorControlTable" REVISION "201211150000Z" -- November 15, 2012 - - DESCRIPTION "1) Removed transferSwitchOutputCapabilities from transferSwitchConfigurationTable - 2) Removed the following tables: - transferSwitchOutputSensorConfigurationTable - transferSwitchOutputSensorLogTable - transferSwitchOutputSensorMeasurementsTable - 3) Removed transferSwitchOutputSensorStateChange trap - 4) Added transferSwitchControlTable - 5) Removed the following entries from SensorTypeEnumeration: - overTemperatureFault - fans - internalFault - inletPhaseDeviationFault - overloadFault - 6) Added the following entries to SensorTypeEnumeration: - overloadStatus - overheatStatus - scrOpenStatus - scrShortStatus - fanStatus - inletPhaseSyncAngle - inletPhaseSync - 7) Added the following entries to SensorStateEnumeration: - inSync, - outOfSync - 8) Renamed transferSwitchNoTransferIfPhaseDeviationFault to - transferSwitchAutoReTransferRequiresPhaseSync - " - + DESCRIPTION + "1) Removed transferSwitchOutputCapabilities from transferSwitchConfigurationTable + 2) Removed the following tables: + transferSwitchOutputSensorConfigurationTable + transferSwitchOutputSensorLogTable + transferSwitchOutputSensorMeasurementsTable + 3) Removed transferSwitchOutputSensorStateChange trap + 4) Added transferSwitchControlTable + 5) Removed the following entries from SensorTypeEnumeration: + overTemperatureFault + fans + internalFault + inletPhaseDeviationFault + overloadFault + 6) Added the following entries to SensorTypeEnumeration: + overloadStatus + overheatStatus + scrOpenStatus + scrShortStatus + fanStatus + inletPhaseSyncAngle + inletPhaseSync + 7) Added the following entries to SensorStateEnumeration: + inSync, + outOfSync + 8) Renamed transferSwitchNoTransferIfPhaseDeviationFault to + transferSwitchAutoReTransferRequiresPhaseSync" REVISION "201210050000Z" -- October 5, 2012 - - DESCRIPTION "1) Modified the DESCRIPTION of the following. - outletSwitchControlTable - transferSwitchOutputSensorMeasurementsEntry - overCurrentProtectorSensorMeasurementsEntry - outletPoleSensorMeasurementsEntry - transferSwitchOutputSensorLogEntry - transferSwitchOutputSensorLogTable - wireSensorLogEntry - externalSensorNumber - controllerConfigurationEntry - SensorUnitsEnumeration - measurementsGroup - logGroup - " - - + DESCRIPTION + "1) Modified the DESCRIPTION of the following: + outletSwitchControlTable + transferSwitchOutputSensorMeasurementsEntry + overCurrentProtectorSensorMeasurementsEntry + outletPoleSensorMeasurementsEntry + transferSwitchOutputSensorLogEntry + transferSwitchOutputSensorLogTable + wireSensorLogEntry + externalSensorNumber + controllerConfigurationEntry + SensorUnitsEnumeration + measurementsGroup + logGroup" REVISION "201210040000Z" -- October 4, 2012 - - DESCRIPTION "1) In the transferSwitchConfigurationTable, - replaced transferSwitchFrequencyDeviation with - transferSwitchLowerMarginalFrequency and transferSwitchUpperMarginalFrequency - " - + DESCRIPTION + "1) In the transferSwitchConfigurationTable, + replaced transferSwitchFrequencyDeviation with + transferSwitchLowerMarginalFrequency and transferSwitchUpperMarginalFrequency" REVISION "201209280000Z" -- September 28, 2012 + DESCRIPTION + "1) Modified the DESCRIPTION of the following: + bulkConfigurationCopied, userModified, userSessionTimeout" - DESCRIPTION "1) Modified the DESCRIPTION of the following. - bulkConfigurationCopied, userModified, userSessionTimeout - " - - REVISION "201209210000Z" -- September 21, 2012 - - DESCRIPTION "1) Added the following traps: - deviceSettingsSaved, deviceSettingsRestored - " - + DESCRIPTION + "1) Added the following traps: + deviceSettingsSaved, deviceSettingsRestored" REVISION "201209200000Z" -- September 20, 2012 - - DESCRIPTION "1) Added the following objects to the transferSwitchConfigurationTable: - transferSwitchInternalFaultType - 2) Added transferSwitchInternalFaultType to transferSwitchSensorStateChange trap - 3) Added marginal to SensorStateEnumeration - " - + DESCRIPTION + "1) Added the following objects to the transferSwitchConfigurationTable: + transferSwitchInternalFaultType + 2) Added transferSwitchInternalFaultType to transferSwitchSensorStateChange trap + 3) Added marginal to SensorStateEnumeration" REVISION "201209170000Z" -- September 17, 2012 - - DESCRIPTION "Deprecated the following objects from the unitConfigurationTable - pxInetAddressType, - pxInetIPAddress, - pxInetNetmask, - pxInetGateway - - " + DESCRIPTION + "1) Deprecated the following objects from the unitConfigurationTable + pxInetAddressType + pxInetIPAddress + pxInetNetmask + pxInetGateway" REVISION "201209040000Z" -- September 4, 2012 + DESCRIPTION + "Support for transfer Switch objects and sensors + 1) Added transferSwitchCount to unitConfigurationTable + 2) Added the following tables: + transferSwitchConfigurationTable + transferSwitchSensorConfigurationTable + transferSwitchSensorLogTable + transferSwitchSensorMeasurementsTable + transferSwitchOutputSensorConfigurationTable + transferSwitchOutputSensorLogTable + transferSwitchOutputSensorMeasurementsTable + 3) Added + transferSwitchSensorStateChange trap + transferSwitchOutputSensorStateChange trap" - DESCRIPTION "Support for transfer Switch objects and sensors. - 1. Added transferSwitchCount to unitConfigurationTable - 2. Added the following tables: - transferSwitchConfigurationTable, - transferSwitchSensorConfigurationTable, - transferSwitchSensorLogTable, - transferSwitchSensorMeasurementsTable - transferSwitchOutputSensorConfigurationTable, - transferSwitchOutputSensorLogTable, - transferSwitchOutputSensorMeasurementsTable - 3. Added - transferSwitchSensorStateChange trap - transferSwitchOutputSensorStateChange trap - - " - REVISION "201206220000Z" -- June 22, 2012 - - DESCRIPTION " - 1. Added surgeProtectorStatus to SensorTypeEnumeration - 2. Added surgeProtectorStatus to inletDeviceCapabilities - " - + DESCRIPTION + "1) Added surgeProtectorStatus to SensorTypeEnumeration + 2) Added surgeProtectorStatus to inletDeviceCapabilities" REVISION "201206180000Z" -- June 18, 2012 - - DESCRIPTION "Added a comment before the section listing the traps. - The comment notes that the pxInetIPAddressType and - pxInetIPAddress fields are not used for IPv6 traps - " - - - - + DESCRIPTION + "1) Added a comment before the section listing the traps. + The comment notes that the pxInetIPAddressType and + pxInetIPAddress fields are not used for IPv6 traps" REVISION "201206060000Z" -- June 6, 2012 + DESCRIPTION + "Support for wire objects and sensors + 1) Added wireCount to unitConfigurationTable + 2) Added the following tables: + wireConfigurationTable + wireSensorConfigurationTable + wireSensorLogTable + wireSensorMeasurementsTable + 3) Added wireSensorStateChange trap" - DESCRIPTION "Support for wire objects and sensors. - 1. Added wireCount to unitConfigurationTable - 2. Added the following tables: - wireConfigurationTable, - wireSensorConfigurationTable, - wireSensorLogTable, - wireSensorMeasurementsTable - 3. Added wireSensorStateChange trap - " + REVISION "201205250000Z" -- May 25, 2012 + DESCRIPTION + "1) Added userAccepted/DeclinedRestrictedServiceAgreement traps" - - REVISION "201205250000Z" -- May 25, 2012 - - - DESCRIPTION "added userAccepted/DeclinedRestrictedServiceAgreement traps" - REVISION "201205150000Z" -- May 15, 2012 - - DESCRIPTION " - 1. Added support for NTP servers. - Added the following objects under info - synchronizeWithNTPServer, useDHCPProvidedNTPServer, - firstNTPServerAddressType, firstNTPServerAddress, - secondNTPServerAddressType, secondNTPServerAddress - - " - + DESCRIPTION + "Added support for NTP servers + 1) Added the following objects under info: + synchronizeWithNTPServer + useDHCPProvidedNTPServer + firstNTPServerAddressType + firstNTPServerAddress + secondNTPServerAddressType + secondNTPServerAddress" REVISION "201203260000Z" -- March 26, 2012 - - DESCRIPTION "added lhxSupportChanged trap." - + DESCRIPTION + "1) Added lhxSupportChanged trap" REVISION "201112130000Z" -- December 13, 2011 - - DESCRIPTION " - 1. Added usbSlaveConnected, usbSlaveDisonnected traps - - " - - - + DESCRIPTION + "1) Added usbSlaveConnected, usbSlaveDisonnected traps" REVISION "201111290000Z" -- November 29, 2011 - - DESCRIPTION " - 1. Added cascadedDeviceConnected to UnitConfigurationEntryStruct - - " - + DESCRIPTION + "1) Added cascadedDeviceConnected to UnitConfigurationEntryStruct" REVISION "201110250000Z" -- October 25, 2011 - - DESCRIPTION " - 1. Added DeviceIdentificationParameterEnumeration - 2. Added deviceIdentificationChanged Trap - 3. Added sysContact, sysName, sysLocation to all traps - - " - + DESCRIPTION + "1) Added DeviceIdentificationParameterEnumeration + 2) Added deviceIdentificationChanged Trap + 3) Added sysContact, sysName, sysLocation to all traps" REVISION "201106160000Z" -- June 16, 2011 - - DESCRIPTION " - 1. Changed DESCRIPTION of outletSequencingDelay - - " - + DESCRIPTION + "1) Changed DESCRIPTION of outletSequencingDelay" REVISION "201103220000Z" -- March 22, 2011 - - DESCRIPTION " - 1. Added rfCodeTagConnected, rfCodeTagDisconnected traps - 2. Changed MAX-ACCESS for externalOnOffSensorSubtype to read-write - " - + DESCRIPTION + "1) Added rfCodeTagConnected, rfCodeTagDisconnected traps + 2) Changed MAX-ACCESS for externalOnOffSensorSubtype to read-write" REVISION "201102210000Z" -- February 21, 2011 - - DESCRIPTION " - 1. Added rpm(19) to SensorUnitsEnumeration - " - + DESCRIPTION + "1) Added rpm(19) to SensorUnitsEnumeration" REVISION "201102140000Z" -- February 14, 2011 - - DESCRIPTION " - 1. Changed 5WIRE IEC60309 enumerations from 250V to 208V - " + DESCRIPTION + "1) Changed 5WIRE IEC60309 enumerations from 250V to 208V" REVISION "201102080000Z" -- February 8, 2011 - - DESCRIPTION " - 1. Removed OnOffSensorSubtypeEnumeration - 2. Changed SYNTAX of externalOnOffSensorSubtype to SensorTypeEnumeration - 3. Added binary, contact, fanspeed, none to SensorTypeEnumeration - 4. Changed outletPoleCapabilities to be the same as inletPoleCapabilities - " + DESCRIPTION + "1) Removed OnOffSensorSubtypeEnumeration + 2) Changed SYNTAX of externalOnOffSensorSubtype to SensorTypeEnumeration + 3) Added binary, contact, fanspeed, none to SensorTypeEnumeration + 4) Changed outletPoleCapabilities to be the same as inletPoleCapabilities" REVISION "201102030000Z" -- February 3, 2011 - - DESCRIPTION " - 1. Added externalSensorSerialNumber,externalOnOffSensorSubtype, externalSensorChannelNumber - to the externalSensorStateChange trap." + DESCRIPTION + "1) Added externalSensorSerialNumber,externalOnOffSensorSubtype, externalSensorChannelNumber + to the externalSensorStateChange trap." REVISION "201101310000Z" -- January 31, 2011 - - DESCRIPTION " - 1. Modifed the DESCRIPTION of the powerControl trap - " - + DESCRIPTION + "1) Modifed the DESCRIPTION of the powerControl trap" REVISION "201012150000Z" -- December 15, 2010 - - DESCRIPTION " - 1. Added dataLoggingEnableForAllSensors to logConfigurationTable - " - + DESCRIPTION + "1) Added dataLoggingEnableForAllSensors to logConfigurationTable" REVISION "201012131131Z" -- December 13, 2010 - - DESCRIPTION " - 1. Added inrushGuardDelay to unitConfigurationTable - 2. Added outletSequenceDelay to outletConfigurationTable - 3. Deprecated outletSequencingDelay - " - + DESCRIPTION + "1) Added inrushGuardDelay to unitConfigurationTable + 2) Added outletSequenceDelay to outletConfigurationTable + 3) Deprecated outletSequencingDelay" REVISION "201012130000Z" -- December 13, 2010 - - DESCRIPTION "1. Added externalOnOffSensorSubtype to ExternalSensorConfigurationEntryStruct - 2. Added OnOffSensorSubtypeEnumeration - 3. Added alarmed to SensorStateEnumeration - 4. Removed firmwareFileDiscarded trap - 5. Removed securityViolation trap - " - + DESCRIPTION + "1) Added externalOnOffSensorSubtype to ExternalSensorConfigurationEntryStruct + 2) Added OnOffSensorSubtypeEnumeration + 3) Added alarmed to SensorStateEnumeration + 4) Removed firmwareFileDiscarded trap + 5) Removed securityViolation trap" REVISION "201012070000Z" -- December 7, 2010 - - DESCRIPTION "1. changed DESCRIPTION of measurementPeriod to say that the value is fixed at 1 second. - " + DESCRIPTION + "1) Changed DESCRIPTION of measurementPeriod to say that the value is fixed at 1 second" REVISION "201010070000Z" -- October 7, 2010 - - DESCRIPTION "1. added ocpFUSEPAIR(5) to OverCurrentProtectorTypeEnumeration - 2. changed ocpFUSE1POLE(4) to ocpFUSE(4) in OverCurrentProtectorTypeEnumeration - " + DESCRIPTION + "1) Added ocpFUSEPAIR(5) to OverCurrentProtectorTypeEnumeration + 2) Changed ocpFUSE1POLE(4) to ocpFUSE(4) in OverCurrentProtectorTypeEnumeration" REVISION "201010040000Z" -- October 4, 2010 - - DESCRIPTION "1. added ocpFUSE2POLE(5) to OverCurrentProtectorTypeEnumeration - 2. changed ocpFUSE(4) to ocpFUSE1POLE(4) in OverCurrentProtectorTypeEnumeration - " + DESCRIPTION + "1) added ocpFUSE2POLE(5) to OverCurrentProtectorTypeEnumeration + 2) changed ocpFUSE(4) to ocpFUSE1POLE(4) in OverCurrentProtectorTypeEnumeration" REVISION "201009010000Z" -- September 1, 2010 - - DESCRIPTION "1. Removed userName from serverNotReachable and serverReachable traps - " + DESCRIPTION + "1) Removed userName from serverNotReachable and serverReachable traps" REVISION "201008050000Z" -- August 5, 2010 - - DESCRIPTION "1. Added reliabilityDataTableSequenceNumber - 2. Changed SYNTAX of reliabilityErrorLogIndex to Integer32(1..2147483647)" + DESCRIPTION + "1) Added reliabilityDataTableSequenceNumber + 2) Changed SYNTAX of reliabilityErrorLogIndex to Integer32(1..2147483647)" REVISION "201007230000Z" -- July 23, 2010 - - DESCRIPTION "1. Moved serverCount to unitConfigurationTable " - + DESCRIPTION + "1) Moved serverCount to unitConfigurationTable" REVISION "201007220000Z" -- July 22, 2010 - - DESCRIPTION "1. Added support for the Reliability Tables - 2. Added new group reliabilityGroup - 3. Defined nodes reliability,reliabilityData,reliabilityErrorLog - 4. Added reliabilityDataTable & reliabilityErrorLogTable" - - + DESCRIPTION + "1) Added support for the Reliability Tables + 2) Added new group reliabilityGroup + 3) Defined nodes reliability,reliabilityData,reliabilityErrorLog + 4) Added reliabilityDataTable & reliabilityErrorLogTable" REVISION "201007210000Z" -- July 21, 2010 - - DESCRIPTION "1. Added plug56PA320 to PlugTypeEnumeration - 2. Added plug56P320F to PlugTypeEnumeration" + DESCRIPTION + "1) Added plug56PA320 to PlugTypeEnumeration + 2) Added plug56P320F to PlugTypeEnumeration" REVISION "201007140000Z" -- July 14, 2010 - - DESCRIPTION "1. Added the following traps: - pingServerEnabled, pingServerDisabled, serverNotReachable, serverReachable - 2. Added the serverReachabilityTable - " - + DESCRIPTION + "1) Added the following traps: + pingServerEnabled + pingServerDisabled + serverNotReachable + serverReachable + 2) Added the serverReachabilityTable" REVISION "201007060000Z" -- July 6, 2010 - - DESCRIPTION "1. Added externalSensorChannelNumber to externalSensorConfigurationTable - " - + DESCRIPTION + "1) Added externalSensorChannelNumber to externalSensorConfigurationTable" - REVISION "201007010000Z" -- July 1, 2010 - - DESCRIPTION "1. added outletSwitchingState to outletSwitchControlTable - 2. added outletSwitchingTimeStamp to outletSwitchControlTable" - - + DESCRIPTION + "1) Added outletSwitchingState to outletSwitchControlTable + 2) Added outletSwitchingTimeStamp to outletSwitchControlTable" REVISION "201006300000Z" -- June 30, 2010 - - DESCRIPTION "1. added switchingOperation to the powerControl trap - " - + DESCRIPTION + "1) Added switchingOperation to the powerControl trap" REVISION "201006210000Z" -- June 21, 2010 - - DESCRIPTION "1. added support for Load shedding - 2. added loadShedding to the unitConfigurationTable. - 3. added nonCritical to the outletConfigurationTable - 4. added loadSheddingModeEntered & loadSheddingModeExited traps - 5. modified description of inletPlug in inletConfigurationTable" + DESCRIPTION + "1) Added support for Load shedding + 2) Added loadShedding to the unitConfigurationTable. + 3) Added nonCritical to the outletConfigurationTable + 4) Added loadSheddingModeEntered & loadSheddingModeExited traps + 5) Modified description of inletPlug in inletConfigurationTable" REVISION "201006030000Z" -- June 3, 2010 - - DESCRIPTION "1. added plugOTHER to PlugTypeEnumeration - 2. added receptacleOTHER to ReceptacleTypeEnumeration - 3. added inletPlugDescriptor to inletConfigurationTable - 4. added outletReceptacleDescriptor to outletConfigurationTable - " + DESCRIPTION + "1) Added plugOTHER to PlugTypeEnumeration + 2) Added receptacleOTHER to ReceptacleTypeEnumeration + 3) Added inletPlugDescriptor to inletConfigurationTable + 4) Added outletReceptacleDescriptor to outletConfigurationTable" REVISION "201005270000Z" -- May 27, 2010 - - DESCRIPTION "1. added INetAddressType and INetAddress to represent IP addresses - 2. unitConfigurationTable: deprecated pxIpAddress - 3. unitConfigurationTable: added pxInetAddressType,pxInetIPAddress,pxInetNetmask,pxInetGateway - 2: added pxInetAddressType,pxInetIPAddress to all traps - 3: defined new trap deviceUpdateFailed" + DESCRIPTION + "1) Added INetAddressType and INetAddress to represent IP addresses + 2) unitConfigurationTable: deprecated pxIpAddress + 3) unitConfigurationTable: added + pxInetAddressType + pxInetIPAddress + pxInetNetmask + pxInetGateway + 4) Added pxInetAddressType,pxInetIPAddress to all traps + 5) Defined new trap deviceUpdateFailed" REVISION "201005240000Z" -- May 24, 2010 - - DESCRIPTION "Added typeOfSensor to externalSensorStateChange trap" + DESCRIPTION + "Added typeOfSensor to externalSensorStateChange trap" REVISION "201004190000Z" -- April 19, 2010 - - DESCRIPTION "modified the DESCRIPTION of the deviceUpdateCompleted trap" + DESCRIPTION + "Modified the DESCRIPTION of the deviceUpdateCompleted trap" REVISION "201004150000Z" -- April 15, 2010 - - DESCRIPTION "modified the DESCRIPTION of all SensorStateChangeDelay parameters" - + DESCRIPTION + "Modified the DESCRIPTION of all SensorStateChangeDelay parameters" REVISION "201004080000Z" -- April 8, 2010 - - DESCRIPTION "modified the DESCRIPTION of sensor parameters that do not apply to discrete sensors" + DESCRIPTION + "Modified the DESCRIPTION of sensor parameters that do not apply to discrete sensors" REVISION "201003290000Z" -- March 29, 2010 - - DESCRIPTION "added trap ldapError" - + DESCRIPTION + "Added trap ldapError" REVISION "201003250000Z" -- March 25, 2010 - - DESCRIPTION "changed the SYNTAX of the following objects from Integer32 to Unsigned32: - logInletSensorMaxValue, - logInletSensorMinValue, - logInletSensorAvgValue, - logInletPoleSensorMaxValue, - logInletPoleSensorMinValue, - logInletPoleSensorAvgValue, - logOutletSensorMaxValue, - logOutletSensorMinValue, - logOutletSensorAvgValue, - logOutletPoleSensorMaxValue, - logOutlePoletSensorMinValue, - logOutletPoleSensorAvgValue, - logOverCurrentProtectorSensorMaxValue, - logOverCurrentProtectorSensorMinValue, - logOverCurrentProtectorSensorAvgValue, - measurementsInletSensorValue, - measurementsInletPoleSensorValue, - measurementsOutletSensorValue, - measurementsOutletPoleSensorValue, - measurementsOverCurrentProtectorSensorValue" + DESCRIPTION + "Changed the SYNTAX of the following objects from Integer32 to Unsigned32: + logInletSensorMaxValue, + logInletSensorMinValue, + logInletSensorAvgValue, + logInletPoleSensorMaxValue, + logInletPoleSensorMinValue, + logInletPoleSensorAvgValue, + logOutletSensorMaxValue, + logOutletSensorMinValue, + logOutletSensorAvgValue, + logOutletPoleSensorMaxValue, + logOutlePoletSensorMinValue, + logOutletPoleSensorAvgValue, + logOverCurrentProtectorSensorMaxValue, + logOverCurrentProtectorSensorMinValue, + logOverCurrentProtectorSensorAvgValue, + measurementsInletSensorValue, + measurementsInletPoleSensorValue, + measurementsOutletSensorValue, + measurementsOutletPoleSensorValue, + measurementsOverCurrentProtectorSensorValue" REVISION "201003160000Z" -- March 16, 2010 - - DESCRIPTION "added trap smtpMessageTransmissionFailure" + DESCRIPTION + "Added trap smtpMessageTransmissionFailure" REVISION "201003010000Z" -- March 1, 2010 - - DESCRIPTION "changed externalSensorsZCoordinateUnits to an Enumeration" + DESCRIPTION + "Changed externalSensorsZCoordinateUnits to an enumeration" REVISION "201001290000Z" -- January 29, 2010 - - DESCRIPTION "The first version of the MIB." + DESCRIPTION + "The first version of the MIB" - - - - ::= { enterprises 13742 } + ::= { enterprises 13742 } -pdu2 OBJECT IDENTIFIER ::= { raritan 6 } +pdu2 OBJECT IDENTIFIER ::= { raritan 6 } -traps OBJECT IDENTIFIER ::= { pdu2 0 } -trapInformation OBJECT IDENTIFIER ::= { traps 0 } -board OBJECT IDENTIFIER ::= { pdu2 1 } -environmental OBJECT IDENTIFIER ::= { pdu2 2 } -configuration OBJECT IDENTIFIER ::= { pdu2 3 } -control OBJECT IDENTIFIER ::= { pdu2 4 } -measurements OBJECT IDENTIFIER ::= { pdu2 5 } -log OBJECT IDENTIFIER ::= { pdu2 6 } -conformance OBJECT IDENTIFIER ::= { pdu2 9 } -reliability OBJECT IDENTIFIER ::= { pdu2 10 } +traps OBJECT IDENTIFIER ::= { pdu2 0 } +trapInformation OBJECT IDENTIFIER ::= { traps 0 } +board OBJECT IDENTIFIER ::= { pdu2 1 } +environmental OBJECT IDENTIFIER ::= { pdu2 2 } +configuration OBJECT IDENTIFIER ::= { pdu2 3 } +control OBJECT IDENTIFIER ::= { pdu2 4 } +measurements OBJECT IDENTIFIER ::= { pdu2 5 } +log OBJECT IDENTIFIER ::= { pdu2 6 } +conformance OBJECT IDENTIFIER ::= { pdu2 9 } +reliability OBJECT IDENTIFIER ::= { pdu2 10 } -unit OBJECT IDENTIFIER ::= { configuration 2 } -inlets OBJECT IDENTIFIER ::= { configuration 3 } -overCurrentProtector OBJECT IDENTIFIER ::= { configuration 4 } -outlets OBJECT IDENTIFIER ::= { configuration 5 } -externalSensors OBJECT IDENTIFIER ::= { configuration 6 } -serverReachability OBJECT IDENTIFIER ::= { configuration 7 } -wires OBJECT IDENTIFIER ::= { configuration 8 } -transferSwitch OBJECT IDENTIFIER ::= { configuration 9 } +unit OBJECT IDENTIFIER ::= { configuration 2 } +inlets OBJECT IDENTIFIER ::= { configuration 3 } +overCurrentProtector OBJECT IDENTIFIER ::= { configuration 4 } +outlets OBJECT IDENTIFIER ::= { configuration 5 } +externalSensors OBJECT IDENTIFIER ::= { configuration 6 } +serverReachability OBJECT IDENTIFIER ::= { configuration 7 } +wires OBJECT IDENTIFIER ::= { configuration 8 } +transferSwitch OBJECT IDENTIFIER ::= { configuration 9 } +powerMeter OBJECT IDENTIFIER ::= { configuration 10 } +circuit OBJECT IDENTIFIER ::= { configuration 11 } +outletControl OBJECT IDENTIFIER ::= { control 1 } +externalSensorControl OBJECT IDENTIFIER ::= { control 2 } +transferSwitchControl OBJECT IDENTIFIER ::= { control 3 } +actuatorControl OBJECT IDENTIFIER ::= { control 4 } +rcmControl OBJECT IDENTIFIER ::= { control 5 } +inletSensorControl OBJECT IDENTIFIER ::= { control 6 } +outletSensorControl OBJECT IDENTIFIER ::= { control 7 } +unitSensorControl OBJECT IDENTIFIER ::= { control 8 } +circuitSensorControl OBJECT IDENTIFIER ::= { control 9 } +measurementsUnit OBJECT IDENTIFIER ::= { measurements 1 } +measurementsInlet OBJECT IDENTIFIER ::= { measurements 2 } +measurementsOverCurrentProtector OBJECT IDENTIFIER ::= { measurements 3 } +measurementsOutlet OBJECT IDENTIFIER ::= { measurements 4 } +measurementsExternalSensor OBJECT IDENTIFIER ::= { measurements 5 } +measurementsWire OBJECT IDENTIFIER ::= { measurements 6 } +measurementsTransferSwitch OBJECT IDENTIFIER ::= { measurements 7 } +measurementsCircuit OBJECT IDENTIFIER ::= { measurements 8 } -outletControl OBJECT IDENTIFIER ::= { control 1 } -externalSensorControl OBJECT IDENTIFIER ::= { control 2 } -transferSwitchControl OBJECT IDENTIFIER ::= { control 3 } -actuatorControl OBJECT IDENTIFIER ::= { control 4 } -rcmControl OBJECT IDENTIFIER ::= { control 5 } -inletSensorControl OBJECT IDENTIFIER ::= { control 6 } -outletSensorControl OBJECT IDENTIFIER ::= { control 7 } -unitSensorControl OBJECT IDENTIFIER ::= { control 8 } +logUnit OBJECT IDENTIFIER ::= { log 1 } +logInlet OBJECT IDENTIFIER ::= { log 2 } +logOverCurrentProtector OBJECT IDENTIFIER ::= { log 3 } +logOutlet OBJECT IDENTIFIER ::= { log 4 } +logExternalSensor OBJECT IDENTIFIER ::= { log 5 } +logWire OBJECT IDENTIFIER ::= { log 6 } +logTransferSwitch OBJECT IDENTIFIER ::= { log 7 } +logCircuit OBJECT IDENTIFIER ::= { log 8 } +reliabilityData OBJECT IDENTIFIER ::= { reliability 1 } +reliabilityErrorLog OBJECT IDENTIFIER ::= { reliability 2 } -measurementsUnit OBJECT IDENTIFIER ::= { measurements 1 } -measurementsInlet OBJECT IDENTIFIER ::= { measurements 2 } -measurementsOverCurrentProtector OBJECT IDENTIFIER ::= { measurements 3 } -measurementsOutlet OBJECT IDENTIFIER ::= { measurements 4 } -measurementsExternalSensor OBJECT IDENTIFIER ::= { measurements 5 } -measurementsWire OBJECT IDENTIFIER ::= { measurements 6 } -measurementsTransferSwitch OBJECT IDENTIFIER ::= { measurements 7 } - -logUnit OBJECT IDENTIFIER ::= { log 1 } -logInlet OBJECT IDENTIFIER ::= { log 2 } -logOverCurrentProtector OBJECT IDENTIFIER ::= { log 3 } -logOutlet OBJECT IDENTIFIER ::= { log 4 } -logExternalSensor OBJECT IDENTIFIER ::= { log 5 } -logWire OBJECT IDENTIFIER ::= { log 6 } -logTransferSwitch OBJECT IDENTIFIER ::= { log 7 } - -reliabilityData OBJECT IDENTIFIER ::= { reliability 1 } -reliabilityErrorLog OBJECT IDENTIFIER ::= { reliability 2 } - - - - - - - - -compliances OBJECT IDENTIFIER ::= { conformance 1 } -groups OBJECT IDENTIFIER ::= { conformance 2 } +compliances OBJECT IDENTIFIER ::= { conformance 1 } +groups OBJECT IDENTIFIER ::= { conformance 2 } -- Conformance Information -- compliance statements +complianceRev2 MODULE-COMPLIANCE + STATUS current + DESCRIPTION + "The requirements for conformance to the PDU2-MIB." + MODULE -- this module -complianceRev2 MODULE-COMPLIANCE - STATUS current - DESCRIPTION - "The requirements for conformance to the PDU2-MIB." - MODULE -- this module + GROUP configGroup + DESCRIPTION + "The configuration group." - GROUP configGroup - DESCRIPTION - "The configuration group." + OBJECT powerMeterPhaseCTRating + MIN-ACCESS read-only + DESCRIPTION + "configuration is not required" - GROUP logGroup - DESCRIPTION - "The log group." + OBJECT powerMeterNeutralCTRating + MIN-ACCESS read-only + DESCRIPTION + "configuration is not required" - GROUP measurementsGroup - DESCRIPTION - "The measurements group." + OBJECT powerMeterEarthCTRating + MIN-ACCESS read-only + DESCRIPTION + "configuration is not required" - GROUP controlGroup - DESCRIPTION - "The control group." + OBJECT circuitName + MIN-ACCESS read-only + DESCRIPTION + "configuration is not required" - GROUP trapInformationGroup - DESCRIPTION - "The information group." + OBJECT circuitRatedCurrent + MIN-ACCESS read-only + DESCRIPTION + "configuration is not required" - GROUP trapsGroup - DESCRIPTION - "The information group." + OBJECT circuitPoleCTNumber + MIN-ACCESS read-only + DESCRIPTION + "configuration is not required" - GROUP reliabilityGroup - DESCRIPTION - "The reliability group." + OBJECT circuitPolePhase + MIN-ACCESS read-only + DESCRIPTION + "configuration is not required" - ::= { compliances 2 } + OBJECT circuitCTRating + MIN-ACCESS read-only + DESCRIPTION + "configuration is not required" -complianceRev1 MODULE-COMPLIANCE - STATUS deprecated - DESCRIPTION - "The requirements for conformance to the PDU2-MIB." - MODULE -- this module + GROUP logGroup + DESCRIPTION + "The log group." - GROUP ipAddressGroup - DESCRIPTION - "The ipAddress group." + GROUP measurementsGroup + DESCRIPTION + "The measurements group." - GROUP oldConfigGroup - DESCRIPTION - "old (deprecated) configuration data" + GROUP controlGroup + DESCRIPTION + "The control group." - GROUP oldLogGroup - DESCRIPTION - "old (deprecated) logging data" + GROUP trapInformationGroup + DESCRIPTION + "The information group." - GROUP oldMeasurementsGroup - DESCRIPTION - "old (deprecated) measurement data" + GROUP trapsGroup + DESCRIPTION + "The information group." - GROUP oldTrapsGroup - DESCRIPTION - "old (deprecated) traps" + GROUP reliabilityGroup + DESCRIPTION + "The reliability group." - ::= { compliances 1 } + ::= { compliances 2 } +complianceRev1 MODULE-COMPLIANCE + STATUS deprecated + DESCRIPTION + "The requirements for conformance to the PDU2-MIB." + MODULE -- this module + GROUP ipAddressGroup + DESCRIPTION + "The ipAddress group." + GROUP oldConfigGroup + DESCRIPTION + "old (deprecated) configuration data" + + GROUP oldLogGroup + DESCRIPTION + "old (deprecated) logging data" + + GROUP oldMeasurementsGroup + DESCRIPTION + "old (deprecated) measurement data" + + GROUP oldTrapsGroup + DESCRIPTION + "old (deprecated) traps" + + ::= { compliances 1 } -- units of conformance -configGroup OBJECT-GROUP - OBJECTS { pduCount, - pduManufacturer, - pduModel, - pduSerialNumber, - pduRatedVoltage, - pduRatedCurrent, - pduRatedFrequency, - pduRatedVA, - pduImage, - inletCount, - transferSwitchCount, - productType, - overCurrentProtectorCount, - outletCount, - inletControllerCount, - outletControllerCount, - meteringControllerCount, - externalSensorCount, - pxMACAddress, - utcOffset, - pduName, - boardVersion, - boardFirmwareVersion, - boardFirmwareTimeStamp, - unitSensorLogAvailable, - unitSensorUnits, - unitSensorDecimalDigits, - unitSensorResolution, - unitSensorMaximum, - unitSensorMinimum, - unitSensorHysteresis, - unitSensorStateChangeDelay, - unitSensorLowerCriticalThreshold, - unitSensorLowerWarningThreshold, - unitSensorUpperCriticalThreshold, - unitSensorUpperWarningThreshold, - unitSensorEnabledThresholds, - unitSensorSignedMaximum, - unitSensorSignedMinimum, - unitSensorSignedLowerCriticalThreshold, - unitSensorSignedLowerWarningThreshold, - unitSensorSignedUpperCriticalThreshold, - unitSensorSignedUpperWarningThreshold, - inletLabel, - inletName, - inletPlug, - inletPoleCount, - inletRatedVoltage, - inletRatedCurrent, - inletRatedFrequency, - inletRatedVA, - inletDeviceCapabilities, - inletPoleCapabilities, - inletPlugDescriptor, - inletEnableState, - inletSensorLogAvailable, - inletSensorUnits, - inletSensorDecimalDigits, - inletSensorResolution, - inletSensorMaximum, - inletSensorMinimum, - inletSensorHysteresis, - inletSensorStateChangeDelay, - inletSensorLowerCriticalThreshold, - inletSensorLowerWarningThreshold, - inletSensorUpperCriticalThreshold, - inletSensorUpperWarningThreshold, - inletSensorEnabledThresholds, - inletSensorSignedMaximum, - inletSensorSignedMinimum, - inletSensorSignedLowerCriticalThreshold, - inletSensorSignedLowerWarningThreshold, - inletSensorSignedUpperCriticalThreshold, - inletSensorSignedUpperWarningThreshold, - inletPoleSensorLogAvailable, - inletPoleSensorUnits, - inletPoleSensorDecimalDigits, - inletPoleSensorResolution, - inletPoleSensorMaximum, - inletPoleSensorMinimum, - inletPoleSensorHysteresis, - inletPoleSensorStateChangeDelay, - inletPoleSensorLowerCriticalThreshold, - inletPoleSensorLowerWarningThreshold, - inletPoleSensorUpperCriticalThreshold, - inletPoleSensorUpperWarningThreshold, - inletPoleSensorEnabledThresholds, - inletPoleSensorSignedMaximum, - inletPoleSensorSignedMinimum, - inletPoleSensorSignedLowerCriticalThreshold, - inletPoleSensorSignedLowerWarningThreshold, - inletPoleSensorSignedUpperCriticalThreshold, - inletPoleSensorSignedUpperWarningThreshold, - inletRCMResidualOperatingCurrent, - overCurrentProtectorLabel, - overCurrentProtectorName, - overCurrentProtectorType, - overCurrentProtectorRatedCurrent, - overCurrentProtectorCapabilities, - overCurrentProtectorSensorLogAvailable, - overCurrentProtectorSensorUnits, - overCurrentProtectorSensorDecimalDigits, - overCurrentProtectorSensorResolution, - overCurrentProtectorSensorMaximum, - overCurrentProtectorSensorMinimum, - overCurrentProtectorSensorHysteresis, - overCurrentProtectorSensorStateChangeDelay, - overCurrentProtectorSensorLowerCriticalThreshold, - overCurrentProtectorSensorLowerWarningThreshold, - overCurrentProtectorSensorUpperCriticalThreshold, - overCurrentProtectorSensorUpperWarningThreshold, - overCurrentProtectorSensorEnabledThresholds, - overCurrentProtectorSensorSignedMaximum, - overCurrentProtectorSensorSignedMinimum, - overCurrentProtectorSensorSignedLowerCriticalThreshold, - overCurrentProtectorSensorSignedLowerWarningThreshold, - overCurrentProtectorSensorSignedUpperCriticalThreshold, - overCurrentProtectorSensorSignedUpperWarningThreshold, - overCurrentProtectorPowerSource, - outletLabel, - outletName, - outletReceptacle, - outletPoleCount, - outletRatedVoltage, - outletRatedCurrent, - outletRatedVA, - outletDeviceCapabilities, - outletPoleCapabilities, - outletPowerCyclingPowerOffPeriod, - outletStateOnStartup, - outletUseGlobalPowerCyclingPowerOffPeriod, - outletSwitchable, - outletReceptacleDescriptor, - outletNonCritical, - outletSequenceDelay, - outletSensorLogAvailable, - outletSensorUnits, - outletSensorDecimalDigits, - outletSensorResolution, - outletSensorMaximum, - outletSensorMinimum, - outletSensorHysteresis, - outletSensorStateChangeDelay, - outletSensorLowerCriticalThreshold, - outletSensorLowerWarningThreshold, - outletSensorUpperCriticalThreshold, - outletSensorUpperWarningThreshold, - outletSensorEnabledThresholds, - outletSensorSignedMaximum, - outletSensorSignedMinimum, - outletSensorSignedLowerCriticalThreshold, - outletSensorSignedLowerWarningThreshold, - outletSensorSignedUpperCriticalThreshold, - outletSensorSignedUpperWarningThreshold, - outletPoleSensorLogAvailable, - outletPoleSensorUnits, - outletPoleSensorDecimalDigits, - outletPoleSensorResolution, - outletPoleSensorMaximum, - outletPoleSensorMinimum, - outletPoleSensorHysteresis, - outletPoleSensorStateChangeDelay, - outletPoleSensorLowerCriticalThreshold, - outletPoleSensorLowerWarningThreshold, - outletPoleSensorUpperCriticalThreshold, - outletPoleSensorUpperWarningThreshold, - outletPoleSensorEnabledThresholds, - outletPoleSensorSignedMaximum, - outletPoleSensorSignedMinimum, - outletPoleSensorSignedLowerCriticalThreshold, - outletPoleSensorSignedLowerWarningThreshold, - outletPoleSensorSignedUpperCriticalThreshold, - outletPoleSensorSignedUpperWarningThreshold, - outletPowerSource, - externalSensorType, - externalSensorSerialNumber, - externalSensorName, - externalSensorDescription, - externalSensorXCoordinate, - externalSensorYCoordinate, - externalSensorZCoordinate, - externalSensorChannelNumber, - externalOnOffSensorSubtype, - externalSensorLogAvailable, - externalSensorUnits, - externalSensorDecimalDigits, - externalSensorResolution, - externalSensorMaximum, - externalSensorMinimum, - externalSensorHysteresis, - externalSensorStateChangeDelay, - externalSensorLowerCriticalThreshold, - externalSensorLowerWarningThreshold, - externalSensorUpperCriticalThreshold, - externalSensorUpperWarningThreshold, - externalSensorEnabledThresholds, - externalSensorsZCoordinateUnits, - externalSensorIsActuator, - externalSensorPosition, - externalSensorUseDefaultThresholds, - externalSensorTypeDefaultHysteresis, - externalSensorTypeDefaultStateChangeDelay, - externalSensorTypeDefaultLowerCriticalThreshold, - externalSensorTypeDefaultLowerWarningThreshold, - externalSensorTypeDefaultUpperCriticalThreshold, - externalSensorTypeDefaultUpperWarningThreshold, - externalSensorTypeDefaultEnabledThresholds, - measurementPeriod, - measurementsPerLogEntry, - logSize, - unitDeviceCapabilities, - globalOutletPowerCyclingPowerOffPeriod, - globalOutletStateOnStartup, - relayBehaviorOnPowerLoss, - pduPowerCyclingPowerOffPeriod, - pduDaisychainMemberType, - managedExternalSensorCount, - outletPowerupSequence, - loadShedding, - serverCount, - serverIPAddress, - serverPingEnabled, - inrushGuardDelay, - cascadedDeviceConnected, - synchronizeWithNTPServer, - useDHCPProvidedNTPServer, - firstNTPServerAddressType, - firstNTPServerAddress, - secondNTPServerAddressType, - secondNTPServerAddress, - transferSwitchLabel, - transferSwitchName, - transferSwitchPreferredInlet, - transferSwitchAutoReTransferEnabled, - transferSwitchAutoReTransferWaitTime, - transferSwitchAutoReTransferRequiresPhaseSync, - transferSwitchFrontPanelManualTransferButtonEnabled, - transferSwitchCapabilities, - transferSwitchSensorLogAvailable, - transferSwitchSensorUnits, - transferSwitchSensorDecimalDigits, - transferSwitchSensorResolution, - transferSwitchSensorMaximum, - transferSwitchSensorMinimum, - transferSwitchSensorHysteresis, - transferSwitchSensorStateChangeDelay, - transferSwitchSensorLowerCriticalThreshold, - transferSwitchSensorLowerWarningThreshold, - transferSwitchSensorUpperCriticalThreshold, - transferSwitchSensorUpperWarningThreshold, - transferSwitchSensorEnabledThresholds, - transferSwitchSensorSignedMaximum, - transferSwitchSensorSignedMinimum, - transferSwitchSensorSignedLowerCriticalThreshold, - transferSwitchSensorSignedLowerWarningThreshold, - transferSwitchSensorSignedUpperCriticalThreshold, - transferSwitchSensorSignedUpperWarningThreshold, - transferSwitchPowerSource1, - transferSwitchPowerSource2, - peripheralDevicePackageSerialNumber, - peripheralDevicePackageModel, - peripheralDevicePackageFirmwareVersion, - peripheralDevicePackageMinFirmwareVersion, - peripheralDevicePackageFirmwareTimeStamp, - peripheralDevicePackagePosition, - peripheralDevicePackageState, - deviceCascadeType, - deviceCascadePosition, - peripheralDevicesAutoManagement, - externalSensorAlarmedToNormalDelay, - frontPanelOutletSwitching, - frontPanelRCMSelfTest, - frontPanelActuatorControl - } - STATUS current - DESCRIPTION - "A collection of objects representing configuration data." - ::= { groups 1 } +configGroup OBJECT-GROUP + OBJECTS { pduCount, + pduManufacturer, + pduModel, + pduSerialNumber, + pduRatedVoltage, + pduRatedCurrent, + pduRatedFrequency, + pduRatedVA, + pduImage, + inletCount, + transferSwitchCount, + productType, + overCurrentProtectorCount, + outletCount, + inletControllerCount, + outletControllerCount, + meteringControllerCount, + externalSensorCount, + circuitCount, + utcOffset, + pduName, + boardVersion, + boardFirmwareVersion, + boardFirmwareTimeStamp, + unitSensorLogAvailable, + unitSensorUnits, + unitSensorDecimalDigits, + unitSensorResolution, + unitSensorMaximum, + unitSensorMinimum, + unitSensorHysteresis, + unitSensorStateChangeDelay, + unitSensorLowerCriticalThreshold, + unitSensorLowerWarningThreshold, + unitSensorUpperCriticalThreshold, + unitSensorUpperWarningThreshold, + unitSensorEnabledThresholds, + unitSensorSignedMaximum, + unitSensorSignedMinimum, + unitSensorSignedLowerCriticalThreshold, + unitSensorSignedLowerWarningThreshold, + unitSensorSignedUpperCriticalThreshold, + unitSensorSignedUpperWarningThreshold, + inletLabel, + inletName, + inletPlug, + inletPoleCount, + inletRatedVoltage, + inletRatedCurrent, + inletDeviceCapabilities, + inletPoleCapabilities, + inletPlugDescriptor, + inletEnableState, + inletPoleLine, + inletPoleNode, + inletSensorLogAvailable, + inletSensorUnits, + inletSensorDecimalDigits, + inletSensorResolution, + inletSensorMaximum, + inletSensorMinimum, + inletSensorHysteresis, + inletSensorStateChangeDelay, + inletSensorLowerCriticalThreshold, + inletSensorLowerWarningThreshold, + inletSensorUpperCriticalThreshold, + inletSensorUpperWarningThreshold, + inletSensorEnabledThresholds, + inletSensorSignedMaximum, + inletSensorSignedMinimum, + inletSensorSignedLowerCriticalThreshold, + inletSensorSignedLowerWarningThreshold, + inletSensorSignedUpperCriticalThreshold, + inletSensorSignedUpperWarningThreshold, + inletPoleSensorLogAvailable, + inletPoleSensorUnits, + inletPoleSensorDecimalDigits, + inletPoleSensorResolution, + inletPoleSensorMaximum, + inletPoleSensorMinimum, + inletPoleSensorHysteresis, + inletPoleSensorStateChangeDelay, + inletPoleSensorLowerCriticalThreshold, + inletPoleSensorLowerWarningThreshold, + inletPoleSensorUpperCriticalThreshold, + inletPoleSensorUpperWarningThreshold, + inletPoleSensorEnabledThresholds, + inletPoleSensorSignedMaximum, + inletPoleSensorSignedMinimum, + inletPoleSensorSignedLowerCriticalThreshold, + inletPoleSensorSignedLowerWarningThreshold, + inletPoleSensorSignedUpperCriticalThreshold, + inletPoleSensorSignedUpperWarningThreshold, + overCurrentProtectorLabel, + overCurrentProtectorName, + overCurrentProtectorType, + overCurrentProtectorRatedCurrent, + overCurrentProtectorCapabilities, + overCurrentProtectorPoleCount, + overCurrentProtectorPoleLine, + overCurrentProtectorPoleInNode, + overCurrentProtectorPoleOutNode, + overCurrentProtectorSensorLogAvailable, + overCurrentProtectorSensorUnits, + overCurrentProtectorSensorDecimalDigits, + overCurrentProtectorSensorResolution, + overCurrentProtectorSensorMaximum, + overCurrentProtectorSensorMinimum, + overCurrentProtectorSensorHysteresis, + overCurrentProtectorSensorStateChangeDelay, + overCurrentProtectorSensorLowerCriticalThreshold, + overCurrentProtectorSensorLowerWarningThreshold, + overCurrentProtectorSensorUpperCriticalThreshold, + overCurrentProtectorSensorUpperWarningThreshold, + overCurrentProtectorSensorEnabledThresholds, + overCurrentProtectorSensorSignedMaximum, + overCurrentProtectorSensorSignedMinimum, + overCurrentProtectorSensorSignedLowerCriticalThreshold, + overCurrentProtectorSensorSignedLowerWarningThreshold, + overCurrentProtectorSensorSignedUpperCriticalThreshold, + overCurrentProtectorSensorSignedUpperWarningThreshold, + overCurrentProtectorPowerSource, + outletLabel, + outletName, + outletReceptacle, + outletPoleCount, + outletRatedVoltage, + outletRatedCurrent, + outletRatedVA, + outletDeviceCapabilities, + outletPoleCapabilities, + outletPowerCyclingPowerOffPeriod, + outletStateOnStartup, + outletUseGlobalPowerCyclingPowerOffPeriod, + outletSwitchable, + outletReceptacleDescriptor, + outletNonCritical, + outletSequenceDelay, + outletPoleLine, + outletPoleNode, + outletSensorLogAvailable, + outletSensorUnits, + outletSensorDecimalDigits, + outletSensorResolution, + outletSensorMaximum, + outletSensorMinimum, + outletSensorHysteresis, + outletSensorStateChangeDelay, + outletSensorLowerCriticalThreshold, + outletSensorLowerWarningThreshold, + outletSensorUpperCriticalThreshold, + outletSensorUpperWarningThreshold, + outletSensorEnabledThresholds, + outletSensorSignedMaximum, + outletSensorSignedMinimum, + outletSensorSignedLowerCriticalThreshold, + outletSensorSignedLowerWarningThreshold, + outletSensorSignedUpperCriticalThreshold, + outletSensorSignedUpperWarningThreshold, + outletPoleSensorLogAvailable, + outletPoleSensorUnits, + outletPoleSensorDecimalDigits, + outletPoleSensorResolution, + outletPoleSensorMaximum, + outletPoleSensorMinimum, + outletPoleSensorHysteresis, + outletPoleSensorStateChangeDelay, + outletPoleSensorLowerCriticalThreshold, + outletPoleSensorLowerWarningThreshold, + outletPoleSensorUpperCriticalThreshold, + outletPoleSensorUpperWarningThreshold, + outletPoleSensorEnabledThresholds, + outletPoleSensorSignedMaximum, + outletPoleSensorSignedMinimum, + outletPoleSensorSignedLowerCriticalThreshold, + outletPoleSensorSignedLowerWarningThreshold, + outletPoleSensorSignedUpperCriticalThreshold, + outletPoleSensorSignedUpperWarningThreshold, + outletPowerSource, + externalSensorType, + externalSensorSerialNumber, + externalSensorName, + externalSensorDescription, + externalSensorXCoordinate, + externalSensorYCoordinate, + externalSensorZCoordinate, + externalSensorChannelNumber, + externalOnOffSensorSubtype, + externalSensorLogAvailable, + externalSensorUnits, + externalSensorDecimalDigits, + externalSensorResolution, + externalSensorMaximum, + externalSensorMinimum, + externalSensorHysteresis, + externalSensorStateChangeDelay, + externalSensorLowerCriticalThreshold, + externalSensorLowerWarningThreshold, + externalSensorUpperCriticalThreshold, + externalSensorUpperWarningThreshold, + externalSensorEnabledThresholds, + externalSensorsZCoordinateUnits, + externalSensorIsActuator, + externalSensorPosition, + externalSensorUseDefaultThresholds, + externalSensorTypeDefaultHysteresis, + externalSensorTypeDefaultStateChangeDelay, + externalSensorTypeDefaultLowerCriticalThreshold, + externalSensorTypeDefaultLowerWarningThreshold, + externalSensorTypeDefaultUpperCriticalThreshold, + externalSensorTypeDefaultUpperWarningThreshold, + externalSensorTypeDefaultEnabledThresholds, + measurementPeriod, + measurementsPerLogEntry, + logSize, + unitDeviceCapabilities, + globalOutletPowerCyclingPowerOffPeriod, + globalOutletStateOnStartup, + relayBehaviorOnPowerLoss, + pduPowerCyclingPowerOffPeriod, + pduDaisychainMemberType, + managedExternalSensorCount, + outletPowerupSequence, + loadShedding, + serverCount, + serverIPAddress, + serverPingEnabled, + inrushGuardDelay, + cascadedDeviceConnected, + synchronizeWithNTPServer, + firstNTPServerAddressType, + firstNTPServerAddress, + secondNTPServerAddressType, + secondNTPServerAddress, + transferSwitchLabel, + transferSwitchName, + transferSwitchPreferredInlet, + transferSwitchPoleCount, + transferSwitchAutoReTransferEnabled, + transferSwitchAutoReTransferWaitTime, + transferSwitchAutoReTransferRequiresPhaseSync, + transferSwitchFrontPanelManualTransferButtonEnabled, + transferSwitchCapabilities, + transferSwitchPoleLine, + transferSwitchPoleIn1Node, + transferSwitchPoleIn2Node, + transferSwitchPoleOutNode, + transferSwitchSensorLogAvailable, + transferSwitchSensorUnits, + transferSwitchSensorDecimalDigits, + transferSwitchSensorResolution, + transferSwitchSensorMaximum, + transferSwitchSensorMinimum, + transferSwitchSensorHysteresis, + transferSwitchSensorStateChangeDelay, + transferSwitchSensorLowerCriticalThreshold, + transferSwitchSensorLowerWarningThreshold, + transferSwitchSensorUpperCriticalThreshold, + transferSwitchSensorUpperWarningThreshold, + transferSwitchSensorEnabledThresholds, + transferSwitchSensorSignedMaximum, + transferSwitchSensorSignedMinimum, + transferSwitchSensorSignedLowerCriticalThreshold, + transferSwitchSensorSignedLowerWarningThreshold, + transferSwitchSensorSignedUpperCriticalThreshold, + transferSwitchSensorSignedUpperWarningThreshold, + transferSwitchPowerSource1, + transferSwitchPowerSource2, + peripheralDevicePackageSerialNumber, + peripheralDevicePackageModel, + peripheralDevicePackageFirmwareVersion, + peripheralDevicePackageMinFirmwareVersion, + peripheralDevicePackageFirmwareTimeStamp, + peripheralDevicePackagePosition, + peripheralDevicePackageState, + deviceCascadeType, + deviceCascadePosition, + peripheralDevicesAutoManagement, + externalSensorAlarmedToNormalDelay, + frontPanelOutletSwitching, + frontPanelRCMSelfTest, + frontPanelActuatorControl, + powerMeterPanelPositions, + powerMeterPanelLayout, + powerMeterPanelNumbering, + powerMeterPhaseCTRating, + powerMeterNeutralCTRating, + powerMeterEarthCTRating, + powerMeterBranchCount, + powerMeterType, + circuitPoleCount, + circuitName, + circuitType, + circuitRatedCurrent, + circuitCTRating, + circuitCapabilities, + circuitPoleCapabilities, + circuitPowerSource, + circuitPolePanelPosition, + circuitPoleCTNumber, + circuitPolePhase, + circuitSensorLogAvailable, + circuitSensorUnits, + circuitSensorDecimalDigits, + circuitSensorResolution, + circuitSensorMaximum, + circuitSensorMinimum, + circuitSensorHysteresis, + circuitSensorStateChangeDelay, + circuitSensorLowerCriticalThreshold, + circuitSensorLowerWarningThreshold, + circuitSensorUpperCriticalThreshold, + circuitSensorUpperWarningThreshold, + circuitSensorEnabledThresholds, + circuitSensorSignedMaximum, + circuitSensorSignedMinimum, + circuitSensorSignedLowerCriticalThreshold, + circuitSensorSignedLowerWarningThreshold, + circuitSensorSignedUpperCriticalThreshold, + circuitSensorSignedUpperWarningThreshold, + circuitPoleSensorLogAvailable, + circuitPoleSensorUnits, + circuitPoleSensorDecimalDigits, + circuitPoleSensorResolution, + circuitPoleSensorMaximum, + circuitPoleSensorMinimum, + circuitPoleSensorHysteresis, + circuitPoleSensorStateChangeDelay, + circuitPoleSensorLowerCriticalThreshold, + circuitPoleSensorLowerWarningThreshold, + circuitPoleSensorUpperCriticalThreshold, + circuitPoleSensorUpperWarningThreshold, + circuitPoleSensorEnabledThresholds, + circuitPoleSensorSignedMaximum, + circuitPoleSensorSignedMinimum, + circuitPoleSensorSignedLowerCriticalThreshold, + circuitPoleSensorSignedLowerWarningThreshold, + circuitPoleSensorSignedUpperCriticalThreshold, + circuitPoleSensorSignedUpperWarningThreshold, + activeDNSServerAddressType, + activeDNSServerAddress, + activeDNSServerCount, + activeNTPServerAddressType, + activeNTPServerAddress, + activeNTPServerCount } + STATUS current + DESCRIPTION + "A collection of objects representing configuration data." + ::= { groups 1 } -ipAddressGroup OBJECT-GROUP - OBJECTS { - pxIPAddress, - netmask, - gateway, - pxInetAddressType, - pxInetIPAddress, - pxInetNetmask, - pxInetGateway - } - STATUS deprecated - DESCRIPTION - "A collection of objects representing configuration data." - ::= { groups 12 } +ipAddressGroup OBJECT-GROUP + OBJECTS { pxIPAddress, + netmask, + gateway, + pxInetAddressType, + pxInetIPAddress, + pxInetNetmask, + pxInetGateway } + STATUS deprecated + DESCRIPTION + "A collection of objects representing configuration data." + ::= { groups 12 } +obsoleteObjectsGroup OBJECT-GROUP + OBJECTS { useDHCPProvidedNTPServer, + inletRCMResidualOperatingCurrent } + STATUS obsolete + DESCRIPTION + "A collection of obsolete objects." + ::= { groups 20 } -oldConfigGroup OBJECT-GROUP - OBJECTS { - outletSequencingDelay, - unitSensorAccuracy, - unitSensorTolerance, - inletSensorAccuracy, - inletSensorTolerance, - inletPoleSensorAccuracy, - inletPoleSensorTolerance, - outletSensorAccuracy, - outletSensorTolerance, - outletPoleSensorAccuracy, - outletPoleSensorTolerance, - overCurrentProtectorSensorAccuracy, - overCurrentProtectorSensorTolerance, - externalSensorAccuracy, - externalSensorTolerance, - wireSensorAccuracy, - wireSensorTolerance, - transferSwitchSensorAccuracy, - transferSwitchSensorTolerance, - wireCount, - wireLabel, - wireCapabilities, - wireSensorLogAvailable, - wireSensorUnits, - wireSensorDecimalDigits, - wireSensorResolution, - wireSensorMaximum, - wireSensorMinimum, - wireSensorHysteresis, - wireSensorStateChangeDelay, - wireSensorLowerCriticalThreshold, - wireSensorLowerWarningThreshold, - wireSensorUpperCriticalThreshold, - wireSensorUpperWarningThreshold, - wireSensorEnabledThresholds, - wirePowerSource - } - STATUS deprecated - DESCRIPTION - "A collection of objects representing old (deprecated) configuration data." - ::= { groups 13 } +oldConfigGroup OBJECT-GROUP + OBJECTS { outletSequencingDelay, + unitSensorAccuracy, + unitSensorTolerance, + inletSensorAccuracy, + inletSensorTolerance, + inletPoleSensorAccuracy, + inletPoleSensorTolerance, + outletSensorAccuracy, + outletSensorTolerance, + outletPoleSensorAccuracy, + outletPoleSensorTolerance, + overCurrentProtectorSensorAccuracy, + overCurrentProtectorSensorTolerance, + externalSensorAccuracy, + externalSensorTolerance, + wireSensorAccuracy, + wireSensorTolerance, + transferSwitchSensorAccuracy, + transferSwitchSensorTolerance, + wireCount, + wireLabel, + wireCapabilities, + wireSensorLogAvailable, + wireSensorUnits, + wireSensorDecimalDigits, + wireSensorResolution, + wireSensorMaximum, + wireSensorMinimum, + wireSensorHysteresis, + wireSensorStateChangeDelay, + wireSensorLowerCriticalThreshold, + wireSensorLowerWarningThreshold, + wireSensorUpperCriticalThreshold, + wireSensorUpperWarningThreshold, + wireSensorEnabledThresholds, + wirePowerSource, + inletRatedFrequency, + inletRatedVA, + pxMACAddress, + networkInterfaceType, + activeDNSServerAddressSource, + activeNTPServerAddressSource } + STATUS deprecated + DESCRIPTION + "A collection of objects representing old (deprecated) configuration data." + ::= { groups 13 } +logGroup OBJECT-GROUP + OBJECTS { dataLogging, + oldestLogID, + newestLogID, + logTimeStamp, + dataLoggingEnableForAllSensors, + logUnitSensorDataAvailable, + logUnitSensorState, + logUnitSensorAvgValue, + logUnitSensorMaxValue, + logUnitSensorMinValue, + logUnitSensorSignedAvgValue, + logUnitSensorSignedMaxValue, + logUnitSensorSignedMinValue, + logInletSensorDataAvailable, + logInletSensorState, + logInletSensorAvgValue, + logInletSensorMaxValue, + logInletSensorMinValue, + logInletSensorSignedAvgValue, + logInletSensorSignedMaxValue, + logInletSensorSignedMinValue, + logInletPoleSensorDataAvailable, + logInletPoleSensorState, + logInletPoleSensorAvgValue, + logInletPoleSensorMaxValue, + logInletPoleSensorMinValue, + logInletPoleSensorSignedAvgValue, + logInletPoleSensorSignedMaxValue, + logInletPoleSensorSignedMinValue, + logOutletSensorDataAvailable, + logOutletSensorState, + logOutletSensorAvgValue, + logOutletSensorMaxValue, + logOutletSensorMinValue, + logOutletSensorSignedAvgValue, + logOutletSensorSignedMaxValue, + logOutletSensorSignedMinValue, + logOutletPoleSensorDataAvailable, + logOutletPoleSensorState, + logOutletPoleSensorAvgValue, + logOutletPoleSensorMaxValue, + logOutletPoleSensorMinValue, + logOutletPoleSensorSignedAvgValue, + logOutletPoleSensorSignedMaxValue, + logOutletPoleSensorSignedMinValue, + logOverCurrentProtectorSensorDataAvailable, + logOverCurrentProtectorSensorState, + logOverCurrentProtectorSensorAvgValue, + logOverCurrentProtectorSensorMaxValue, + logOverCurrentProtectorSensorMinValue, + logOverCurrentProtectorSensorSignedAvgValue, + logOverCurrentProtectorSensorSignedMaxValue, + logOverCurrentProtectorSensorSignedMinValue, + logExternalSensorDataAvailable, + logExternalSensorState, + logExternalSensorAvgValue, + logExternalSensorMaxValue, + logExternalSensorMinValue, + logTransferSwitchSensorDataAvailable, + logTransferSwitchSensorState, + logTransferSwitchSensorAvgValue, + logTransferSwitchSensorMaxValue, + logTransferSwitchSensorMinValue, + logTransferSwitchSensorSignedAvgValue, + logTransferSwitchSensorSignedMaxValue, + logTransferSwitchSensorSignedMinValue, + logCircuitSensorDataAvailable, + logCircuitSensorState, + logCircuitSensorAvgValue, + logCircuitSensorMaxValue, + logCircuitSensorMinValue, + logCircuitSensorSignedAvgValue, + logCircuitSensorSignedMaxValue, + logCircuitSensorSignedMinValue, + logCircuitPoleSensorDataAvailable, + logCircuitPoleSensorState, + logCircuitPoleSensorAvgValue, + logCircuitPoleSensorMaxValue, + logCircuitPoleSensorMinValue, + logCircuitPoleSensorSignedAvgValue, + logCircuitPoleSensorSignedMaxValue, + logCircuitPoleSensorSignedMinValue } + STATUS current + DESCRIPTION + "A collection of objects providing logging (history of readings) capabilities + about the PDU." + ::= { groups 2 } -logGroup OBJECT-GROUP - OBJECTS { - dataLogging, - oldestLogID, - newestLogID, - logTimeStamp, - dataLoggingEnableForAllSensors, - logUnitSensorDataAvailable, - logUnitSensorState, - logUnitSensorAvgValue, - logUnitSensorMaxValue, - logUnitSensorMinValue, - logUnitSensorSignedAvgValue, - logUnitSensorSignedMaxValue, - logUnitSensorSignedMinValue, - logInletSensorDataAvailable, - logInletSensorState, - logInletSensorAvgValue, - logInletSensorMaxValue, - logInletSensorMinValue, - logInletSensorSignedAvgValue, - logInletSensorSignedMaxValue, - logInletSensorSignedMinValue, - logInletPoleSensorDataAvailable, - logInletPoleSensorState, - logInletPoleSensorAvgValue, - logInletPoleSensorMaxValue, - logInletPoleSensorMinValue, - logInletPoleSensorSignedAvgValue, - logInletPoleSensorSignedMaxValue, - logInletPoleSensorSignedMinValue, - logOutletSensorDataAvailable, - logOutletSensorState, - logOutletSensorAvgValue, - logOutletSensorMaxValue, - logOutletSensorMinValue, - logOutletSensorSignedAvgValue, - logOutletSensorSignedMaxValue, - logOutletSensorSignedMinValue, - logOutletPoleSensorDataAvailable, - logOutletPoleSensorState, - logOutletPoleSensorAvgValue, - logOutletPoleSensorMaxValue, - logOutletPoleSensorMinValue, - logOutletPoleSensorSignedAvgValue, - logOutletPoleSensorSignedMaxValue, - logOutletPoleSensorSignedMinValue, - logOverCurrentProtectorSensorDataAvailable, - logOverCurrentProtectorSensorState, - logOverCurrentProtectorSensorAvgValue, - logOverCurrentProtectorSensorMaxValue, - logOverCurrentProtectorSensorMinValue, - logOverCurrentProtectorSensorSignedAvgValue, - logOverCurrentProtectorSensorSignedMaxValue, - logOverCurrentProtectorSensorSignedMinValue, - logExternalSensorDataAvailable, - logExternalSensorState, - logExternalSensorAvgValue, - logExternalSensorMaxValue, - logExternalSensorMinValue, - logTransferSwitchSensorDataAvailable, - logTransferSwitchSensorState, - logTransferSwitchSensorAvgValue, - logTransferSwitchSensorMaxValue, - logTransferSwitchSensorMinValue, - logTransferSwitchSensorSignedAvgValue, - logTransferSwitchSensorSignedMaxValue, - logTransferSwitchSensorSignedMinValue - } - STATUS current - DESCRIPTION - "A collection of objects providing logging (history of readings) capabilities - about the PDU." - ::= { groups 2 } +oldLogGroup OBJECT-GROUP + OBJECTS { logWireSensorDataAvailable, + logWireSensorState, + logWireSensorAvgValue, + logWireSensorMaxValue, + logWireSensorMinValue } + STATUS deprecated + DESCRIPTION + "A collection of objects representing old (deprecated) logging data." + ::= { groups 14 } +measurementsGroup OBJECT-GROUP + OBJECTS { measurementsUnitSensorIsAvailable, + measurementsUnitSensorState, + measurementsUnitSensorValue, + measurementsUnitSensorTimeStamp, + measurementsUnitSensorSignedValue, + measurementsInletSensorIsAvailable, + measurementsInletSensorState, + measurementsInletSensorValue, + measurementsInletSensorTimeStamp, + measurementsInletSensorSignedValue, + measurementsInletPoleSensorIsAvailable, + measurementsInletPoleSensorState, + measurementsInletPoleSensorValue, + measurementsInletPoleSensorTimeStamp, + measurementsInletPoleSensorSignedValue, + measurementsOutletSensorIsAvailable, + measurementsOutletSensorState, + measurementsOutletSensorValue, + measurementsOutletSensorTimeStamp, + measurementsOutletSensorSignedValue, + measurementsOutletPoleSensorIsAvailable, + measurementsOutletPoleSensorState, + measurementsOutletPoleSensorValue, + measurementsOutletPoleSensorTimeStamp, + measurementsOutletPoleSensorSignedValue, + measurementsOverCurrentProtectorSensorIsAvailable, + measurementsOverCurrentProtectorSensorState, + measurementsOverCurrentProtectorSensorValue, + measurementsOverCurrentProtectorSensorTimeStamp, + measurementsOverCurrentProtectorSensorSignedValue, + measurementsExternalSensorIsAvailable, + measurementsExternalSensorState, + measurementsExternalSensorValue, + measurementsExternalSensorTimeStamp, + measurementsTransferSwitchSensorIsAvailable, + measurementsTransferSwitchSensorState, + measurementsTransferSwitchSensorValue, + measurementsTransferSwitchSensorTimeStamp, + measurementsTransferSwitchSensorSignedValue, + measurementsCircuitSensorIsAvailable, + measurementsCircuitSensorState, + measurementsCircuitSensorValue, + measurementsCircuitSensorTimeStamp, + measurementsCircuitSensorSignedValue, + measurementsCircuitPoleSensorIsAvailable, + measurementsCircuitPoleSensorState, + measurementsCircuitPoleSensorValue, + measurementsCircuitPoleSensorTimeStamp, + measurementsCircuitPoleSensorSignedValue } + STATUS current + DESCRIPTION + "A collection of objects providing measurements (most recent data) capabilities. + about the PDU." + ::= { groups 3 } -oldLogGroup OBJECT-GROUP - OBJECTS { - logWireSensorDataAvailable, - logWireSensorState, - logWireSensorAvgValue, - logWireSensorMaxValue, - logWireSensorMinValue - } - STATUS deprecated - DESCRIPTION - "A collection of objects representing old (deprecated) logging data." - ::= { groups 14 } - -measurementsGroup OBJECT-GROUP - OBJECTS { - measurementsUnitSensorIsAvailable, - measurementsUnitSensorState, - measurementsUnitSensorValue, - measurementsUnitSensorTimeStamp, - measurementsUnitSensorSignedValue, - measurementsInletSensorIsAvailable, - measurementsInletSensorState, - measurementsInletSensorValue, - measurementsInletSensorTimeStamp, - measurementsInletSensorSignedValue, - measurementsInletPoleSensorIsAvailable, - measurementsInletPoleSensorState, - measurementsInletPoleSensorValue, - measurementsInletPoleSensorTimeStamp, - measurementsInletPoleSensorSignedValue, - measurementsOutletSensorIsAvailable, - measurementsOutletSensorState, - measurementsOutletSensorValue, - measurementsOutletSensorTimeStamp, - measurementsOutletSensorSignedValue, - measurementsOutletPoleSensorIsAvailable, - measurementsOutletPoleSensorState, - measurementsOutletPoleSensorValue, - measurementsOutletPoleSensorTimeStamp, - measurementsOutletPoleSensorSignedValue, - measurementsOverCurrentProtectorSensorIsAvailable, - measurementsOverCurrentProtectorSensorState, - measurementsOverCurrentProtectorSensorValue, - measurementsOverCurrentProtectorSensorTimeStamp, - measurementsOverCurrentProtectorSensorSignedValue, - measurementsExternalSensorIsAvailable, - measurementsExternalSensorState, - measurementsExternalSensorValue, - measurementsExternalSensorTimeStamp, - measurementsTransferSwitchSensorIsAvailable, - measurementsTransferSwitchSensorState, - measurementsTransferSwitchSensorValue, - measurementsTransferSwitchSensorTimeStamp, - measurementsTransferSwitchSensorSignedValue - } - STATUS current - DESCRIPTION - "A collection of objects providing measurements (most recent data) capabilities. - about the PDU." - ::= { groups 3 } - - -oldMeasurementsGroup OBJECT-GROUP - OBJECTS { - measurementsWireSensorIsAvailable, - measurementsWireSensorState, - measurementsWireSensorValue, - measurementsWireSensorTimeStamp - } - STATUS deprecated - DESCRIPTION - "A collection of objects representing old (deprecated) measurement data." - ::= { groups 15 } - -controlGroup OBJECT-GROUP - OBJECTS { - switchingOperation, - outletSwitchingState, - outletSwitchingTimeStamp, - transferSwitchActiveInlet, - transferSwitchTransferToInlet, - transferSwitchAlarmOverride, - transferSwitchLastTransferReason, - actuatorState, - rcmState, - inletSensorResetValue, - outletSensorResetValue, - unitSensorResetValue - } - STATUS current - DESCRIPTION - "A collection of objects providing the ability to control various components - of a PDU." - ::= { groups 4 } +oldMeasurementsGroup OBJECT-GROUP + OBJECTS { measurementsWireSensorIsAvailable, + measurementsWireSensorState, + measurementsWireSensorValue, + measurementsWireSensorTimeStamp } + STATUS deprecated + DESCRIPTION + "A collection of objects representing old (deprecated) measurement data." + ::= { groups 15 } +controlGroup OBJECT-GROUP + OBJECTS { switchingOperation, + outletSwitchingState, + outletSwitchingTimeStamp, + transferSwitchActiveInlet, + transferSwitchTransferToInlet, + transferSwitchAlarmOverride, + transferSwitchLastTransferReason, + actuatorState, + rcmState, + inletSensorResetValue, + outletSensorResetValue, + unitSensorResetValue, + circuitSensorResetValue } + STATUS current + DESCRIPTION + "A collection of objects providing the ability to control various components + of a PDU." + ::= { groups 4 } trapInformationGroup OBJECT-GROUP - OBJECTS { - userName, - targetUser, - imageVersion, - roleName, - oldSensorState, - pduNumber, - inletPoleNumber, - outletPoleNumber, - externalSensorNumber, - typeOfSensor, - smtpMessageRecipients, - smtpServer, - errorDescription, - deviceChangedParameter, - changedParameterNewValue, - lhxSupportEnabled, - webcamModel, - webcamConnectionPort, - agentInetPortNumber, - peripheralDeviceRomcode, - peripheralDeviceFirmwareUpdateState - } - STATUS current - DESCRIPTION - "A collection of objects providing information in the traps." - ::= { groups 5 } + OBJECTS { userName, + targetUser, + imageVersion, + roleName, + oldSensorState, + pduNumber, + inletPoleNumber, + outletPoleNumber, + externalSensorNumber, + typeOfSensor, + smtpMessageRecipients, + smtpServer, + errorDescription, + deviceChangedParameter, + changedParameterNewValue, + lhxSupportEnabled, + webcamModel, + webcamConnectionPort, + agentInetPortNumber, + peripheralDeviceRomcode, + peripheralDeviceFirmwareUpdateState, + circuitNumber, + circuitPoleNumber, + phoneNumber, + smartCardReaderId, + smartCardTimestamp, + smartCardType, + smartCardId, + suspectedTripCauseLabel } + STATUS current + DESCRIPTION + "A collection of objects providing information in the traps." + ::= { groups 5 } +trapsGroup NOTIFICATION-GROUP + NOTIFICATIONS { systemStarted, + systemReset, + userLogin, + userLogout, + userAuthenticationFailure, + userSessionTimeout, + userAdded, + userModified, + userDeleted, + roleAdded, + roleModified, + roleDeleted, + deviceUpdateStarted, + deviceUpdateCompleted, + userBlocked, + powerControl, + userPasswordChanged, + passwordSettingsChanged, + firmwareValidationFailed, + logFileCleared, + bulkConfigurationSaved, + bulkConfigurationCopied, + inletSensorStateChange, + inletPoleSensorStateChange, + outletSensorStateChange, + outletPoleSensorStateChange, + overCurrentProtectorSensorStateChange, + externalSensorStateChange, + smtpMessageTransmissionFailure, + ldapError, + deviceUpdateFailed, + loadSheddingModeEntered, + loadSheddingModeExited, + pingServerEnabled, + pingServerDisabled, + serverNotReachable, + serverReachable, + deviceIdentificationChanged, + usbSlaveConnected, + usbSlaveDisconnected, + lhxSupportChanged, + userAcceptedRestrictedServiceAgreement, + userDeclinedRestrictedServiceAgreement, + transferSwitchSensorStateChange, + deviceSettingsSaved, + deviceSettingsRestored, + webcamInserted, + webcamRemoved, + inletEnabled, + inletDisabled, + serverConnectivityUnrecoverable, + radiusError, + serverReachabilityError, + inletSensorReset, + outletSensorReset, + unitSensorReset, + circuitSensorReset, + unknownPeripheralDeviceAttached, + peripheralDeviceFirmwareUpdate, + unitSensorStateChange, + circuitSensorStateChange, + circuitPoleSensorStateChange, + circuitAdded, + circuitDeleted, + circuitModified, + powerMeterAdded, + powerMeterDeleted, + powerMeterModified, + smsMessageTransmissionFailure, + smartCardInserted, + smartCardRemoved } + STATUS current + DESCRIPTION + "A collection of traps." + ::= { groups 9 } -trapsGroup NOTIFICATION-GROUP - NOTIFICATIONS { systemStarted, - systemReset, - userLogin, - userLogout, - userAuthenticationFailure, - userSessionTimeout, - userAdded, - userModified, - userDeleted, - roleAdded, - roleModified, - roleDeleted, - deviceUpdateStarted, - deviceUpdateCompleted, - userBlocked, - powerControl, - userPasswordChanged, - passwordSettingsChanged, - firmwareValidationFailed, - logFileCleared, - bulkConfigurationSaved, - bulkConfigurationCopied, - inletSensorStateChange, - inletPoleSensorStateChange, - outletSensorStateChange, - outletPoleSensorStateChange, - overCurrentProtectorSensorStateChange, - externalSensorStateChange, - smtpMessageTransmissionFailure, - ldapError, - deviceUpdateFailed, - loadSheddingModeEntered, - loadSheddingModeExited, - pingServerEnabled, - pingServerDisabled, - serverNotReachable, - serverReachable, - rfCodeTagConnected, - rfCodeTagDisconnected, - deviceIdentificationChanged, - usbSlaveConnected, - usbSlaveDisconnected, - lhxSupportChanged, - userAcceptedRestrictedServiceAgreement, - userDeclinedRestrictedServiceAgreement, - transferSwitchSensorStateChange, - deviceSettingsSaved, - deviceSettingsRestored, - webcamInserted, - webcamRemoved, - inletEnabled, - inletDisabled, - serverConnectivityUnrecoverable, - radiusError, - serverReachabilityError, - inletSensorReset, - outletSensorReset, - unitSensorReset, - unknownPeripheralDeviceAttached, - peripheralDeviceFirmwareUpdate, - unitSensorStateChange - } - STATUS current - DESCRIPTION - "A collection of traps." - ::= { groups 9 } +oldTrapsGroup NOTIFICATION-GROUP + NOTIFICATIONS { wireSensorStateChange, + pduSensorStateChange, + rfCodeTagConnected, + rfCodeTagDisconnected } + STATUS deprecated + DESCRIPTION + "A collection of objects representing old (deprecated) traps." + ::= { groups 16 } -oldTrapsGroup NOTIFICATION-GROUP - NOTIFICATIONS { wireSensorStateChange, - pduSensorStateChange - } - STATUS deprecated - DESCRIPTION - "A collection of objects representing old (deprecated) traps." - ::= { groups 16 } - -reliabilityGroup OBJECT-GROUP - OBJECTS { - reliabilityId, - reliabilityDataValue, - reliabilityDataMaxPossible, - reliabilityDataWorstValue, - reliabilityDataThreshold, - reliabilityDataRawUpperBytes, - reliabilityDataRawLowerBytes, - reliabilityDataFlags, - reliabilityErrorLogId, - reliabilityErrorLogValue, - reliabilityErrorLogThreshold, - reliabilityErrorLogRawUpperBytes, - reliabilityErrorLogRawLowerBytes, - reliabilityErrorLogPOH, - reliabilityErrorLogTime, - reliabilityDataTableSequenceNumber - - } - STATUS current - DESCRIPTION - "A collection of objects providing reliability data." - ::= { groups 10 } +reliabilityGroup OBJECT-GROUP + OBJECTS { reliabilityId, + reliabilityDataValue, + reliabilityDataMaxPossible, + reliabilityDataWorstValue, + reliabilityDataThreshold, + reliabilityDataRawUpperBytes, + reliabilityDataRawLowerBytes, + reliabilityDataFlags, + reliabilityErrorLogId, + reliabilityErrorLogValue, + reliabilityErrorLogThreshold, + reliabilityErrorLogRawUpperBytes, + reliabilityErrorLogRawLowerBytes, + reliabilityErrorLogPOH, + reliabilityErrorLogTime, + reliabilityDataTableSequenceNumber } + STATUS current + DESCRIPTION + "A collection of objects providing reliability data." + ::= { groups 10 } -- Textual Conventions - - SensorTypeEnumeration ::= TEXTUAL-CONVENTION - STATUS current - DESCRIPTION - "The types a sensor can be." - SYNTAX INTEGER { - rmsCurrent(1), - peakCurrent(2), - unbalancedCurrent(3), - rmsVoltage(4), - activePower(5), - apparentPower(6), - powerFactor(7), - activeEnergy(8), - apparentEnergy(9), - temperature(10), - humidity(11), - airFlow(12), - airPressure(13), - onOff(14), - trip(15), - vibration(16), - waterDetection(17), - smokeDetection(18), - binary(19), - contact(20), - fanSpeed(21), - surgeProtectorStatus(22), - frequency(23), - phaseAngle(24), - rmsVoltageLN(25), - residualCurrent(26), - rcmState(27), - other(30), - none(31), - powerQuality(32), - overloadStatus(33), - overheatStatus(34), - fanStatus(37), - inletPhaseSyncAngle(38), - inletPhaseSync(39), - operatingState(40), - activeInlet(41), - illuminance(42), - doorContact(43), - tamperDetection(44), - motionDetection(45), - i1smpsStatus(46), - i2smpsStatus(47), - switchStatus(48) - } - - + STATUS current + DESCRIPTION + "The types a sensor can be." + SYNTAX INTEGER { rmsCurrent(1), + peakCurrent(2), + unbalancedCurrent(3), + rmsVoltage(4), + activePower(5), + apparentPower(6), + powerFactor(7), + activeEnergy(8), + apparentEnergy(9), + temperature(10), + humidity(11), + airFlow(12), + airPressure(13), + onOff(14), + trip(15), + vibration(16), + waterDetection(17), + smokeDetection(18), + binary(19), + contact(20), + fanSpeed(21), + surgeProtectorStatus(22), + frequency(23), + phaseAngle(24), + rmsVoltageLN(25), + residualCurrent(26), + rcmState(27), + absoluteHumidity(28), + reactivePower(29), + other(30), + none(31), + powerQuality(32), + overloadStatus(33), + overheatStatus(34), + displacementPowerFactor(35), + fanStatus(37), + inletPhaseSyncAngle(38), + inletPhaseSync(39), + operatingState(40), + activeInlet(41), + illuminance(42), + doorContact(43), + tamperDetection(44), + motionDetection(45), + i1smpsStatus(46), + i2smpsStatus(47), + switchStatus(48), + doorLockState(49), + doorHandleLock(50) } SensorStateEnumeration ::= TEXTUAL-CONVENTION - STATUS current - DESCRIPTION - "The states a sensor can be in." - SYNTAX INTEGER { unavailable(-1), - open(0), - closed(1), - belowLowerCritical(2), - belowLowerWarning(3), - normal(4), - aboveUpperWarning(5), - aboveUpperCritical(6), - on(7), - off(8), - detected(9), - notDetected(10), - alarmed(11), - ok(12), - fail(14), - yes(15), - no(16), - standby(17), - one(18), - two(19), - inSync(20), - outOfSync(21), - i1OpenFault(22), - i1ShortFault(23), - i2OpenFault(24), - i2ShortFault(25), - fault(26), - warning(27), - critical(28), - selfTest(29) - } - --- Possible Sensor States for each Sensor Type --- This comment must be updated whenever a new sensor type is added. --- Sensor Type Sensor States --- rmsCurrent unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical --- peakCurrent unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical --- unbalancedCurrent unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical --- rmsVoltage unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical --- activePower unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical --- apparentPower unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical --- powerFactor unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical --- activeEnergy unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical --- apparentEnergy unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical --- temperature unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical --- humidity unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical --- airFlow unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical --- airPressure unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical --- onOff unavailable,on,off --- trip unavailable,open,closed --- vibration unavailable,normal,alarmed --- waterDetection unavailable,normal,alarmed --- smokeDetection unavailable,normal,alarmed --- binary unavailable,normal,alarmed --- contact unavailable,normal,alarmed --- fanSpeed unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical --- surgeProtectorStatus unavailable,ok,fault --- frequency unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical --- phaseAngle unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical --- powerQuality unavailable,normal,warning,critical --- overloadStatus unavailable,ok,fault --- overheatStatus unavailable,ok,fault --- fanStatus unavailable,ok,fault --- residualCurrent unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical --- rcmState unavailable,normal,alarmed,selfTest,fail --- inletPhaseSyncAngle unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical --- inletPhaseSync unavailable,inSync,outOfSync --- operatingState unavailable,normal,standby,off --- activeInlet unavailable,one,two,none --- illuminance unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical --- doorContact unavailable,open,closed --- tamperDetection unavailable,normal,alarmed --- motionDetection unavailable,?? --- i1smpsStatus unavailable,ok,fault --- i2smpsStatus unavailable,ok,fault --- switchStatus unavailable,ok,i1OpenFault,i1ShortFault,i2OpenFault,i2ShortFault - + STATUS current + DESCRIPTION + "The states a sensor can be in." + SYNTAX INTEGER { unavailable(-1), + open(0), + closed(1), + belowLowerCritical(2), + belowLowerWarning(3), + normal(4), + aboveUpperWarning(5), + aboveUpperCritical(6), + on(7), + off(8), + detected(9), + notDetected(10), + alarmed(11), + ok(12), + fail(14), + yes(15), + no(16), + standby(17), + one(18), + two(19), + inSync(20), + outOfSync(21), + i1OpenFault(22), + i1ShortFault(23), + i2OpenFault(24), + i2ShortFault(25), + fault(26), + warning(27), + critical(28), + selfTest(29), + nonRedundant(30) } +-- Possible Sensor States for each Sensor Type +-- This comment must be updated whenever a new sensor type is added. +-- Sensor Type Sensor States +-- rmsCurrent unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical +-- peakCurrent unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical +-- unbalancedCurrent unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical +-- rmsVoltage unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical +-- activePower unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical +-- apparentPower unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical +-- powerFactor unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical +-- activeEnergy unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical +-- apparentEnergy unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical +-- temperature unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical +-- humidity unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical +-- airFlow unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical +-- airPressure unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical +-- onOff unavailable,on,off +-- trip unavailable,open,closed +-- vibration unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical +-- waterDetection unavailable,normal,alarmed +-- smokeDetection unavailable,normal,alarmed +-- binary unavailable,normal,alarmed +-- contact unavailable,normal,alarmed +-- fanSpeed unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical +-- surgeProtectorStatus unavailable,ok,fault +-- frequency unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical +-- phaseAngle unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical +-- powerQuality unavailable,normal,warning,critical +-- overloadStatus unavailable,ok,fault +-- overheatStatus unavailable,ok,fault +-- fanStatus unavailable,ok,fault +-- residualCurrent unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical +-- rcmState unavailable,normal,warning,critical,selfTest,fail +-- reactivePower unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical +-- inletPhaseSyncAngle unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical +-- inletPhaseSync unavailable,inSync,outOfSync +-- operatingState unavailable,normal,standby,nonRedundant,off +-- activeInlet unavailable,one,two,off +-- illuminance unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical +-- doorContact unavailable,open,closed +-- tamperDetection unavailable,normal,alarmed +-- motionDetection unavailable,?? +-- i1smpsStatus unavailable,ok,fault +-- i2smpsStatus unavailable,ok,fault +-- switchStatus unavailable,ok,i1OpenFault,i1ShortFault,i2OpenFault,i2ShortFault +-- displacementPowerFactor unavailable,belowLowerCritical,belowLowerWarning,normal,aboveUpperWarning,aboveUpperCritical +-- doorLockState unavailable,open,closed +-- doorHandleLock unavailable,open,closed +-- doorHandleSwitch unavailable,open,closed PlugTypeEnumeration ::= TEXTUAL-CONVENTION - STATUS current - DESCRIPTION - "The types of inlet plug." - SYNTAX INTEGER { plugOTHER(-1), - plugNONE(0), - plug56P320(1), - plug56P520(2), - plug56P532(3), - plugCS8365C(4), - plugIEC320C14(5), - plugIEC320C20(6), - plugIEC603093WIRE250V16A(7), - plugIEC603093WIRE250V20A(8), - plugIEC603093WIRE250V30A(9), - plugIEC603093WIRE250V32A(10), - plugIEC603093WIRE250V60A(11), - plugIEC603093WIRE250V63A(12), - plugIEC603093WIRE250V100A(13), - plugIEC603093WIRE250V125A(14), - plugIEC603094WIRE250V20A(15), - plugIEC603094WIRE250V30A(16), - plugIEC603094WIRE250V60A(17), - plugIEC603094WIRE250V100A(18), - plugIEC603095WIRE208V20A(23), - plugIEC603095WIRE208V30A(24), - plugIEC603095WIRE208V60A(25), - plugIEC603095WIRE208V100A(26), - plugIEC603095WIRE415V16A(27), - plugIEC603095WIRE415V32A(28), - plugIEC603095WIRE415V63A(29), - plugIEC603095WIRE415V125A(30), - plugIEC603095WIRE480V20A(31), - plugIEC603095WIRE480V30A(32), - plugIEC603095WIRE480V60A(33), - plugIEC603095WIRE480V100A(34), - plugNEMA515P(35), - plugNEMAL515P(36), - plugNEMA520P(37), - plugNEMAL520P(38), - plugNEMAL530P(39), - plugNEMAL615P(40), - plugNEMAL620P(41), - plugNEMAL630P(42), - plugNEMAL1520P(43), - plugNEMAL1530P(44), - plugNEMAL2120P(45), - plugNEMAL2130P(46), - plugNEMAL2230P(47), - plug56P320F(48), - plug56PA320(49) - - } + STATUS current + DESCRIPTION + "The types of inlet plug." + SYNTAX INTEGER { plugOTHER(-1), + plugNONE(0), + plug56P320(1), + plug56P520(2), + plug56P532(3), + plugCS8365C(4), + plugIEC320C14(5), + plugIEC320C20(6), + plugIEC603093WIRE250V16A(7), + plugIEC603093WIRE250V20A(8), + plugIEC603093WIRE250V30A(9), + plugIEC603093WIRE250V32A(10), + plugIEC603093WIRE250V60A(11), + plugIEC603093WIRE250V63A(12), + plugIEC603093WIRE250V100A(13), + plugIEC603093WIRE250V125A(14), + plugIEC603094WIRE250V20A(15), + plugIEC603094WIRE250V30A(16), + plugIEC603094WIRE250V60A(17), + plugIEC603094WIRE250V100A(18), + plugIEC603095WIRE208V20A(23), + plugIEC603095WIRE208V30A(24), + plugIEC603095WIRE208V60A(25), + plugIEC603095WIRE208V100A(26), + plugIEC603095WIRE415V16A(27), + plugIEC603095WIRE415V32A(28), + plugIEC603095WIRE415V63A(29), + plugIEC603095WIRE415V125A(30), + plugIEC603095WIRE480V20A(31), + plugIEC603095WIRE480V30A(32), + plugIEC603095WIRE480V60A(33), + plugIEC603095WIRE480V100A(34), + plugNEMA515P(35), + plugNEMAL515P(36), + plugNEMA520P(37), + plugNEMAL520P(38), + plugNEMAL530P(39), + plugNEMAL615P(40), + plugNEMAL620P(41), + plugNEMAL630P(42), + plugNEMAL1520P(43), + plugNEMAL1530P(44), + plugNEMAL2120P(45), + plugNEMAL2130P(46), + plugNEMAL2230P(47), + plug56P320F(48), + plug56PA320(49) } ReceptacleTypeEnumeration ::= TEXTUAL-CONVENTION - STATUS current - DESCRIPTION - "The types of outlet receptacle." - SYNTAX INTEGER { receptacleOTHER(-1), - receptacleNONE(0), - receptacleBS1363(1), - receptacle56P532(3), - receptacleCS8364C(4), - receptacleIEC320C13(5), - receptacleIEC320C19(6), - receptacleIEC603093WIRE250V16A(7), - receptacleIEC603093WIRE250V20A(8), - receptacleIEC603093WIRE250V30A(9), - receptacleIEC603093WIRE250V32A(10), - receptacleIEC603093WIRE250V60A(11), - receptacleIEC603093WIRE250V63A(12), - receptacleIEC603093WIRE250V100A(13), - receptacleIEC603093WIRE250V125A(14), - receptacleIEC603094WIRE250V20A(15), - receptacleIEC603094WIRE250V30A(16), - receptacleIEC603094WIRE250V60A(17), - receptacleIEC603094WIRE250V100A(18), - receptacleIEC603095WIRE208V20A(23), - receptacleIEC603095WIRE208V30A(24), - receptacleIEC603095WIRE208V60A(25), - receptacleIEC603095WIRE208V100A(26), - receptacleIEC603095WIRE415V16A(27), - receptacleIEC603095WIRE415V32A(28), - receptacleIEC603095WIRE415V63A(29), - receptacleIEC603095WIRE415V125A(30), - receptacleIEC603095WIRE480V20A(31), - receptacleIEC603095WIRE480V30A(32), - receptacleIEC603095WIRE480V60A(33), - receptacleIEC603095WIRE480V100A(34), - receptacleNEMA515R(35), - receptacleNEMAL515R(36), - receptacleNEMA520R(37), - receptacleNEMAL520R(38), - receptacleNEMAL530R(39), - receptacleNEMAL615R(40), - receptacleNEMAL620R(41), - receptacleNEMAL630R(42), - receptacleNEMAL1520R(43), - receptacleNEMAL1530R(44), - receptacleNEMAL2120RP(45), - receptacleNEMAL2130R(46), - receptacleSCHUKOTYPEE(47), - receptacleSCHUKOTYPEF(48) - } + STATUS current + DESCRIPTION + "The types of outlet receptacle." + SYNTAX INTEGER { receptacleOTHER(-1), + receptacleNONE(0), + receptacleBS1363(1), + receptacle56P532(3), + receptacleCS8364C(4), + receptacleIEC320C13(5), + receptacleIEC320C19(6), + receptacleIEC603093WIRE250V16A(7), + receptacleIEC603093WIRE250V20A(8), + receptacleIEC603093WIRE250V30A(9), + receptacleIEC603093WIRE250V32A(10), + receptacleIEC603093WIRE250V60A(11), + receptacleIEC603093WIRE250V63A(12), + receptacleIEC603093WIRE250V100A(13), + receptacleIEC603093WIRE250V125A(14), + receptacleIEC603094WIRE250V20A(15), + receptacleIEC603094WIRE250V30A(16), + receptacleIEC603094WIRE250V60A(17), + receptacleIEC603094WIRE250V100A(18), + receptacleIEC603095WIRE208V20A(23), + receptacleIEC603095WIRE208V30A(24), + receptacleIEC603095WIRE208V60A(25), + receptacleIEC603095WIRE208V100A(26), + receptacleIEC603095WIRE415V16A(27), + receptacleIEC603095WIRE415V32A(28), + receptacleIEC603095WIRE415V63A(29), + receptacleIEC603095WIRE415V125A(30), + receptacleIEC603095WIRE480V20A(31), + receptacleIEC603095WIRE480V30A(32), + receptacleIEC603095WIRE480V60A(33), + receptacleIEC603095WIRE480V100A(34), + receptacleNEMA515R(35), + receptacleNEMAL515R(36), + receptacleNEMA520R(37), + receptacleNEMAL520R(38), + receptacleNEMAL530R(39), + receptacleNEMAL615R(40), + receptacleNEMAL620R(41), + receptacleNEMAL630R(42), + receptacleNEMAL1520R(43), + receptacleNEMAL1530R(44), + receptacleNEMAL2120RP(45), + receptacleNEMAL2130R(46), + receptacleSCHUKOTYPEE(47), + receptacleSCHUKOTYPEF(48) } OverCurrentProtectorTypeEnumeration ::= TEXTUAL-CONVENTION - STATUS current - DESCRIPTION - "The types of overcurrent protectors." - SYNTAX INTEGER { ocpBREAKER1POLE(1), - ocpBREAKER2POLE(2), - ocpBREAKER3POLE(3), - ocpFUSE(4), - ocpFUSEPAIR(5), - ocpRCBO2POLE(6), - ocpRCBO3POLE(7), - ocpRCBO4POLE(8) - } - + STATUS current + DESCRIPTION + "The types of overcurrent protectors." + SYNTAX INTEGER { ocpBREAKER1POLE(1), + ocpBREAKER2POLE(2), + ocpBREAKER3POLE(3), + ocpFUSE(4), + ocpFUSEPAIR(5), + ocpRCBO2POLE(6), + ocpRCBO3POLE(7), + ocpRCBO4POLE(8) } BoardTypeEnumeration ::= TEXTUAL-CONVENTION - STATUS current - DESCRIPTION - "The types of boards." - SYNTAX INTEGER { mainController(1), - inletController(2), - outletController(3), - meteringController(4) - } - + STATUS current + DESCRIPTION + "The types of boards." + SYNTAX INTEGER { mainController(1), + inletController(2), + outletController(3), + meteringController(4) } OutletSwitchingOperationsEnumeration ::= TEXTUAL-CONVENTION - STATUS current - DESCRIPTION - "The switching operations on an outlet." - SYNTAX INTEGER { off(0), - on(1), - cycle(2) - } - - - + STATUS current + DESCRIPTION + "The switching operations on an outlet." + SYNTAX INTEGER { off(0), + on(1), + cycle(2) } SensorUnitsEnumeration ::= TEXTUAL-CONVENTION - STATUS current - DESCRIPTION - "The sensor units." - SYNTAX INTEGER { none(-1), - other(0), - volt(1), - amp(2), - watt(3), - voltamp(4), - wattHour(5), - voltampHour(6), - degreeC(7), - hertz(8), - percent(9), - meterpersec(10), - pascal(11), - psi(12), - g(13), - degreeF(14), - feet(15), - inches(16), - cm(17), - meters(18), - rpm(19), - degrees(20), - lux(21) - } + STATUS current + DESCRIPTION + "The sensor units." + SYNTAX INTEGER { none(-1), + other(0), + volt(1), + amp(2), + watt(3), + voltamp(4), + wattHour(5), + voltampHour(6), + degreeC(7), + hertz(8), + percent(9), + meterpersec(10), + pascal(11), + psi(12), + g(13), + degreeF(14), + feet(15), + inches(16), + cm(17), + meters(18), + rpm(19), + degrees(20), + lux(21), + grampercubicmeter(22), + var(23) } DaisychainMemberTypeEnumeration ::= TEXTUAL-CONVENTION - STATUS current - DESCRIPTION - "The daisy chain member type." - SYNTAX INTEGER { standalone(0), - master(1), - slave(2) - } - + STATUS current + DESCRIPTION + "The daisy chain member type." + SYNTAX INTEGER { standalone(0), + master(1), + slave(2) } URL ::= TEXTUAL-CONVENTION - DISPLAY-HINT "255a" - STATUS current - DESCRIPTION - "A Uniform Resource Locator (URL), as defined in RFC1738." - SYNTAX OCTET STRING (SIZE (0..255)) - + DISPLAY-HINT "255a" + STATUS current + DESCRIPTION + "A Uniform Resource Locator (URL), as defined in RFC1738." + SYNTAX OCTET STRING (SIZE (0..255)) GlobalOutletStateOnStartupEnumeration ::= TEXTUAL-CONVENTION - STATUS current - DESCRIPTION - "The global outlet state on device start up; can be overridden per outlet." - SYNTAX INTEGER { - off(0), - on(1), - lastKnownState(2) - } + STATUS current + DESCRIPTION + "The global outlet state on device start up; can be overridden per outlet." + SYNTAX INTEGER { off(0), + on(1), + lastKnownState(2) } OutletStateOnStartupEnumeration ::= TEXTUAL-CONVENTION - STATUS current - DESCRIPTION - "The outlet state on device start up; this overrides the global value." - SYNTAX INTEGER { off(0), - on(1), - lastKnownState(2), - globalOutletStateOnStartup(3) - } - + STATUS current + DESCRIPTION + "The outlet state on device start up; this overrides the global value." + SYNTAX INTEGER { off(0), + on(1), + lastKnownState(2), + globalOutletStateOnStartup(3) } ExternalSensorsZCoordinateUnitsEnumeration ::= TEXTUAL-CONVENTION - STATUS current - DESCRIPTION - "The units of the external Sensor Z Coordinate. - rackUnits implies that the Z Coordinate for all external sensors - is in rack Units (U) - text implies that the Z Coordinate for all external sensors - is a text string (label) " - SYNTAX INTEGER { rackUnits(0), - text(1) - } + STATUS current + DESCRIPTION + "The units of the external sensor Z coordinate. + rackUnits implies that the Z coordinate for all external sensors + is in rack units (U) + text implies that the Z coordinate for all external sensors + is a text string (label)" + SYNTAX INTEGER { rackUnits(0), + text(1) } - - -HundredthsOfAPercentage ::= TEXTUAL-CONVENTION - DISPLAY-HINT "d" - STATUS current - DESCRIPTION - "Data type for reporting values in hundredths of percentage, i.e. 0.01 %." - SYNTAX Unsigned32 (0..10000) +HundredthsOfAPercentage ::= TEXTUAL-CONVENTION + DISPLAY-HINT "d" + STATUS current + DESCRIPTION + "Data type for reporting values in hundredths of percentage, i.e. 0.01 %." + SYNTAX Unsigned32 (0..10000) DeviceIdentificationParameterEnumeration ::= TEXTUAL-CONVENTION - STATUS current - DESCRIPTION - "The configurable parameters." - SYNTAX INTEGER { pduName(0), - sysContact(1), - sysName(2), - sysLocation(3) - } - + STATUS current + DESCRIPTION + "The configurable parameters." + SYNTAX INTEGER { pduName(0), + sysContact(1), + sysName(2), + sysLocation(3) } TransferSwitchTransferReasonEnumeration ::= TEXTUAL-CONVENTION - STATUS current - DESCRIPTION - "Transfer Switch Transfer Reason" - SYNTAX INTEGER { - unknown(0), - startup(1), - manualTransfer(2), - automaticReTransfer(3), - powerFailure(4), - powerQuality(5), - overloadAlarm(6), - overheatAlarm(7), - internalFailure(8) - } + STATUS current + DESCRIPTION + "Transfer Switch Transfer Reason" + SYNTAX INTEGER { unknown(0), + startup(1), + manualTransfer(2), + automaticReTransfer(3), + powerFailure(4), + powerQuality(5), + overloadAlarm(6), + overheatAlarm(7), + internalFailure(8) } ProductTypeEnumeration ::= TEXTUAL-CONVENTION - STATUS current - DESCRIPTION - "The product types." - SYNTAX INTEGER { rackPdu(0), - bcm(1), - transferSwitch(2) - } + STATUS current + DESCRIPTION + "The product types." + SYNTAX INTEGER { rackPdu(0), + bcm(1), + transferSwitch(2), + powerMeter(3) } RelayPowerLossBehaviorEnumeration ::= TEXTUAL-CONVENTION - STATUS current - DESCRIPTION - "The type of relay behavior on power loss." - SYNTAX INTEGER { - nonLatching(0), - latching(1) - } - + STATUS current + DESCRIPTION + "The type of relay behavior on power loss." + SYNTAX INTEGER { nonLatching(0), + latching(1) } DeviceCascadeTypeEnumeration ::= TEXTUAL-CONVENTION - STATUS current - DESCRIPTION - "The type of configured cascading on this device." - SYNTAX INTEGER { - bridging(0), - portForwarding(1) - } + STATUS current + DESCRIPTION + "The type of configured cascading on this device." + SYNTAX INTEGER { bridging(0), + portForwarding(1), + none(2) } PeripheralDeviceFirmwareUpdateStateEnumeration ::= TEXTUAL-CONVENTION - STATUS current - DESCRIPTION - "The state of an peripheral device firmware update." - SYNTAX INTEGER { started(1), - successful(2), - failed(3) - } + STATUS current + DESCRIPTION + "The state of a peripheral device firmware update." + SYNTAX INTEGER { started(1), + successful(2), + failed(3) } --- the Unit group +PanelLayoutEnumeration ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "The panel circuit position layout." + SYNTAX INTEGER { invalid(-1), + oneColumn(1), + twoColumns(2) } --- Implementation for managing the PDUs +PanelNumberingEnumeration ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "The panel circuit position numbering scheme." + SYNTAX INTEGER { invalid(-1), + oddEven(1), + sequential(2) } -pduCount OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The number of PDUs" - ::= { configuration 1 } +CircuitTypeEnumeration ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "The panel circuit types." + SYNTAX INTEGER { onePhaseLL(1), + onePhaseLN(2), + onePhaseLLN(3), + threePhase(4) } +PhaseEnumeration ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "The power phase." + SYNTAX INTEGER { phaseA(1), + phaseB(2), + phaseC(3), + neutral(4), + earth(5) } --- the Nameplate table +LineEnumeration ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "The Lines: L1, L2, L3, N." + SYNTAX INTEGER { lineL1(1), + lineL2(2), + lineL3(3), + lineNeutral(4) } --- The Nameplate table contains information on the PDU's nameplate. +PowerMeterTypeEnumeration ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "The power meter types" + SYNTAX INTEGER { singlePhase(1), + splitPhase(2), + threePhase(3) } +NetworkInterfaceTypeEnumeration ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "The type of network interface." + SYNTAX INTEGER { wired(0), + wireless(1) } -nameplateTable OBJECT-TYPE - SYNTAX SEQUENCE OF NameplateEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A list of PDU nameplate entries. The number of - entries is given by the value of pduCount." - ::= { unit 1 } +AddressSourceEnumeration ::= TEXTUAL-CONVENTION + STATUS current + DESCRIPTION + "How was the address obtained?" + SYNTAX INTEGER { static(1), + dhcp(2), + dhcpv6(3) } -nameplateEntry OBJECT-TYPE - SYNTAX NameplateEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "An entry providing PDU nameplate information." - INDEX { pduId } - ::= { nameplateTable 1 } +-- Global OIDs -NameplateEntryStruct ::= SEQUENCE { pduId Integer32, - pduManufacturer DisplayString, - pduModel DisplayString, - pduSerialNumber DisplayString, - pduRatedVoltage DisplayString, - pduRatedCurrent DisplayString, - pduRatedFrequency DisplayString, - pduRatedVA DisplayString, - pduImage URL - - } +pduCount OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of PDUs managed by this MIB. -pduId OBJECT-TYPE - SYNTAX Integer32(1..256) - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A unique value for each PDU. Its value - ranges between 1 and the value of pduCount." - ::= { nameplateEntry 1 } + For PX2, PX3 and PX3TS, pduCount is always 1 + For BCM2, pduCount is the number of power meters plus 1 (for the main controller)" + ::= { configuration 1 } -pduManufacturer OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The PDU manaufacturer." - ::= { nameplateEntry 2 } +-- nameplateTable: PDU nameplate information -pduModel OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The PDU model." - ::= { nameplateEntry 3 } +nameplateTable OBJECT-TYPE + SYNTAX SEQUENCE OF NameplateEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of PDU nameplate entries. The number of + entries is given by the value of pduCount." + ::= { unit 1 } +nameplateEntry OBJECT-TYPE + SYNTAX NameplateEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry providing PDU nameplate information." + INDEX { pduId } + ::= { nameplateTable 1 } -pduSerialNumber OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The PDU serial Number." - ::= { nameplateEntry 4 } +NameplateEntryStruct ::= SEQUENCE { + pduId Integer32, + pduManufacturer DisplayString, + pduModel DisplayString, + pduSerialNumber DisplayString, + pduRatedVoltage DisplayString, + pduRatedCurrent DisplayString, + pduRatedFrequency DisplayString, + pduRatedVA DisplayString, + pduImage URL + } +pduId OBJECT-TYPE + SYNTAX Integer32(0..256) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A unique value for each PDU or power meter. -pduRatedVoltage OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The PDU voltage rating." - ::= { nameplateEntry 5 } + For PX2, PX3 and PX3TS, pduId is always 1 + For BCM2, pduId can be: + - 0 for the main controller + - The meter ID (rotary switch) for power meter" + ::= { nameplateEntry 1 } +pduManufacturer OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The PDU manufacturer." + ::= { nameplateEntry 2 } -pduRatedCurrent OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The PDU current rating." - ::= { nameplateEntry 6 } +pduModel OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The PDU model name." + ::= { nameplateEntry 3 } -pduRatedFrequency OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The PDU frequency rating." - ::= { nameplateEntry 7 } +pduSerialNumber OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The PDU serial number." + ::= { nameplateEntry 4 } +pduRatedVoltage OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The PDU voltage rating." + ::= { nameplateEntry 5 } -pduRatedVA OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The PDU VA (VoltAmps) rating." - ::= { nameplateEntry 8 } +pduRatedCurrent OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The PDU current rating." + ::= { nameplateEntry 6 } +pduRatedFrequency OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The PDU frequency rating." + ::= { nameplateEntry 7 } -pduImage OBJECT-TYPE - SYNTAX URL - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The URL of the wiring diagram for this PDU." - - ::= { nameplateEntry 9} +pduRatedVA OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The PDU VA (VoltAmps) rating." + ::= { nameplateEntry 8 } +pduImage OBJECT-TYPE + SYNTAX URL + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The URL of the wiring diagram for this PDU." + ::= { nameplateEntry 9 } +-- unitConfigurationTable: PDU configuration and settings --- the UnitConfiguration table +unitConfigurationTable OBJECT-TYPE + SYNTAX SEQUENCE OF UnitConfigurationEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of PDU configuration entries. The number of + entries is given by the value of pduCount." + ::= { unit 2 } --- The UnitConfiguration table contains information on the PDU's configuration. +unitConfigurationEntry OBJECT-TYPE + SYNTAX UnitConfigurationEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing configuration objects for a particular PDU." + INDEX { pduId } + ::= { unitConfigurationTable 1 } +UnitConfigurationEntryStruct ::= SEQUENCE { + inletCount Integer32, + overCurrentProtectorCount Integer32, + outletCount Integer32, + inletControllerCount Integer32, + outletControllerCount Integer32, + externalSensorCount Integer32, + pxIPAddress IpAddress, + netmask IpAddress, + gateway IpAddress, + pxMACAddress MacAddress, + utcOffset DisplayString, + pduName DisplayString, + networkInterfaceType NetworkInterfaceTypeEnumeration, + externalSensorsZCoordinateUnits ExternalSensorsZCoordinateUnitsEnumeration, + unitDeviceCapabilities BITS, + outletSequencingDelay Unsigned32, + globalOutletPowerCyclingPowerOffPeriod Unsigned32, + globalOutletStateOnStartup GlobalOutletStateOnStartupEnumeration, + outletPowerupSequence DisplayString, + pduPowerCyclingPowerOffPeriod Unsigned32, + pduDaisychainMemberType DaisychainMemberTypeEnumeration, + managedExternalSensorCount Integer32, + pxInetAddressType InetAddressType, + pxInetIPAddress InetAddress, + pxInetNetmask InetAddress, + pxInetGateway InetAddress, + loadShedding TruthValue, + serverCount Integer32, + inrushGuardDelay Unsigned32, + cascadedDeviceConnected TruthValue, + synchronizeWithNTPServer TruthValue, + useDHCPProvidedNTPServer TruthValue, + firstNTPServerAddressType InetAddressType, + firstNTPServerAddress InetAddress, + secondNTPServerAddressType InetAddressType, + secondNTPServerAddress InetAddress, + wireCount Integer32, + transferSwitchCount Integer32, + productType ProductTypeEnumeration, + meteringControllerCount Integer32, + relayBehaviorOnPowerLoss RelayPowerLossBehaviorEnumeration, + deviceCascadeType DeviceCascadeTypeEnumeration, + deviceCascadePosition Integer32, + peripheralDevicesAutoManagement TruthValue, + frontPanelOutletSwitching TruthValue, + frontPanelRCMSelfTest TruthValue, + frontPanelActuatorControl TruthValue, + circuitCount Integer32, + activeDNSServerCount Integer32, + activeNTPServerCount Integer32 + } -unitConfigurationTable OBJECT-TYPE - SYNTAX SEQUENCE OF UnitConfigurationEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A list of PDU configuration entries. The number of - entries is given by the value of pduCount." - ::= { unit 2 } +inletCount OBJECT-TYPE + SYNTAX Integer32(1..256) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of inlets." + ::= { unitConfigurationEntry 2 } -unitConfigurationEntry OBJECT-TYPE - SYNTAX UnitConfigurationEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "An entry containing configuration objects for a particular PDU." - INDEX { pduId } - ::= { unitConfigurationTable 1 } +overCurrentProtectorCount OBJECT-TYPE + SYNTAX Integer32(0..255) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of overcurrent protectors." + ::= { unitConfigurationEntry 3 } -UnitConfigurationEntryStruct ::= SEQUENCE { - inletCount Integer32, - overCurrentProtectorCount Integer32, - outletCount Integer32, - inletControllerCount Integer32, - outletControllerCount Integer32, - externalSensorCount Integer32, - pxIPAddress IpAddress, - netmask IpAddress, - gateway IpAddress, - pxMACAddress MacAddress, - utcOffset DisplayString, - pduName DisplayString, - externalSensorsZCoordinateUnits ExternalSensorsZCoordinateUnitsEnumeration, - unitDeviceCapabilities BITS, - outletSequencingDelay Unsigned32, - globalOutletPowerCyclingPowerOffPeriod Unsigned32, - globalOutletStateOnStartup GlobalOutletStateOnStartupEnumeration, - outletPowerupSequence DisplayString, - pduPowerCyclingPowerOffPeriod Unsigned32, - pduDaisychainMemberType DaisychainMemberTypeEnumeration, - managedExternalSensorCount Integer32, - pxInetAddressType InetAddressType, - pxInetIPAddress InetAddress, - pxInetNetmask InetAddress, - pxInetGateway InetAddress, - loadShedding TruthValue, - serverCount Integer32, - inrushGuardDelay Unsigned32, - cascadedDeviceConnected TruthValue, - synchronizeWithNTPServer TruthValue, - useDHCPProvidedNTPServer TruthValue, - firstNTPServerAddressType InetAddressType, - firstNTPServerAddress InetAddress, - secondNTPServerAddressType InetAddressType, - secondNTPServerAddress InetAddress, - wireCount Integer32, - transferSwitchCount Integer32, - productType ProductTypeEnumeration, - meteringControllerCount Integer32, - relayBehaviorOnPowerLoss RelayPowerLossBehaviorEnumeration, - deviceCascadeType DeviceCascadeTypeEnumeration, - deviceCascadePosition Integer32, - peripheralDevicesAutoManagement TruthValue, - frontPanelOutletSwitching TruthValue, - frontPanelRCMSelfTest TruthValue, - frontPanelActuatorControl TruthValue - } +outletCount OBJECT-TYPE + SYNTAX Integer32(1..256) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of outlets." + ::= { unitConfigurationEntry 4 } +inletControllerCount OBJECT-TYPE + SYNTAX Integer32(0..255) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of inlet controllers." + ::= { unitConfigurationEntry 5 } +outletControllerCount OBJECT-TYPE + SYNTAX Integer32(0..255) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of outlet controllers." + ::= { unitConfigurationEntry 6 } -inletCount OBJECT-TYPE - SYNTAX Integer32(1..256) - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The number of inlets." - ::= { unitConfigurationEntry 2 } +externalSensorCount OBJECT-TYPE + SYNTAX Integer32(0..255) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The maximum supported number of external sensors. This value is + fixed and does not reflect how many sensors are actually connected." + ::= { unitConfigurationEntry 7 } -overCurrentProtectorCount OBJECT-TYPE - SYNTAX Integer32(0..255) - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The number of overcurrent protectors." - ::= { unitConfigurationEntry 3 } +pxIPAddress OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The current IP address. A value of 0.0.0.0 indicates an error + or an unset option." + ::= { unitConfigurationEntry 8 } -outletCount OBJECT-TYPE - SYNTAX Integer32(1..256) - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The number of outlets." - ::= { unitConfigurationEntry 4 } +netmask OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The current netmask. A value of 0.0.0.0 indicates an error + or an unset option." + ::= { unitConfigurationEntry 9 } -inletControllerCount OBJECT-TYPE - SYNTAX Integer32(0..255) - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The number of inlet controllers." - ::= { unitConfigurationEntry 5 } +gateway OBJECT-TYPE + SYNTAX IpAddress + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The current gateway. A value of 0.0.0.0 indicates an error + or an unset option." + ::= { unitConfigurationEntry 10 } +pxMACAddress OBJECT-TYPE + SYNTAX MacAddress + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The current MAC address. + If bridge interface is enabled, then equal to the MAC address of Ethernet 1 + else if Ethernet 1 is enabled, then equal to the MAC address of Ethernet 1 + else if Ethernet 2 is enabled, then equal to the MAC address of Ethernet 2 + else if Wlan is enabled, then equal to the MAC address of Wlan + else return SNMP_ERR_NOSUCHNAME" + ::= { unitConfigurationEntry 11 } -outletControllerCount OBJECT-TYPE - SYNTAX Integer32(0..255) - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The number of outlet controllers." - ::= { unitConfigurationEntry 6 } +utcOffset OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current UTC offset." + ::= { unitConfigurationEntry 12 } -externalSensorCount OBJECT-TYPE - SYNTAX Integer32(0..255) - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The number of external sensors." - ::= { unitConfigurationEntry 7 } +pduName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The user-defined name for the PDU." + ::= { unitConfigurationEntry 13 } - -pxIPAddress OBJECT-TYPE - SYNTAX IpAddress - MAX-ACCESS read-only - STATUS deprecated - DESCRIPTION - "The current IP address. A value of 0.0.0.0 indicates an error - or an unset option." - ::= { unitConfigurationEntry 8 } - -netmask OBJECT-TYPE - SYNTAX IpAddress - MAX-ACCESS read-only - STATUS deprecated - DESCRIPTION - "The current netmask. A value of 0.0.0.0 indicates an error - or an unset option." - ::= { unitConfigurationEntry 9 } - - -gateway OBJECT-TYPE - SYNTAX IpAddress - MAX-ACCESS read-only - STATUS deprecated - DESCRIPTION - "The current gateway. A value of 0.0.0.0 indicates an error - or an unset option." - ::= { unitConfigurationEntry 10 } - -pxMACAddress OBJECT-TYPE - SYNTAX MacAddress - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The current MAC address." - ::= { unitConfigurationEntry 11 } - - -utcOffset OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The current UTC offset." - ::= { unitConfigurationEntry 12 } - -pduName OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The user-defined name for the PDU." - ::= { unitConfigurationEntry 13 } - - - - - +networkInterfaceType OBJECT-TYPE + SYNTAX NetworkInterfaceTypeEnumeration + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The network interface type: wired or wireless. + If only the Wireless interface is enabled, then equal to wireless + else equal to wired" + ::= { unitConfigurationEntry 14 } externalSensorsZCoordinateUnits OBJECT-TYPE - SYNTAX ExternalSensorsZCoordinateUnitsEnumeration - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "External Sensor Z Coordinate units: Freeform Text or Rack Units (U) - Default is U." - ::= { unitConfigurationEntry 34 } + SYNTAX ExternalSensorsZCoordinateUnitsEnumeration + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "External sensor Z coordinate units: freeform text or rack units (U) + Default is U." + ::= { unitConfigurationEntry 34 } -unitDeviceCapabilities OBJECT-TYPE - SYNTAX BITS{ - i1smpsStatus(45), - i2smpsStatus(46) - } - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "A bit string which indicates which unit sensors are available." - ::= { unitConfigurationEntry 35 } +unitDeviceCapabilities OBJECT-TYPE + SYNTAX BITS{ i1smpsStatus(45), + i2smpsStatus(46) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A bit string indicating which unit sensors are available." + ::= { unitConfigurationEntry 35 } -outletSequencingDelay OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS deprecated - DESCRIPTION - "It is deprecated. This is an alias for inrushGuardDelay - " - ::= { unitConfigurationEntry 36 } +outletSequencingDelay OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS deprecated + DESCRIPTION + "It is deprecated. This is an alias for inrushGuardDelay" + ::= { unitConfigurationEntry 36 } +globalOutletPowerCyclingPowerOffPeriod OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The power-off period when an outlet is cycled; + applies to all outlets unless overridden at the outlet level; + specified in seconds; + 1 <= value <= 3600 seconds." + ::= { unitConfigurationEntry 37 } -globalOutletPowerCyclingPowerOffPeriod OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The power-off period when an outlet is cycled; - applies to all outlets unless overridden at the outlet level; - specified in seconds; - 0 <= value <= 3600 seconds." - ::= { unitConfigurationEntry 37 } +globalOutletStateOnStartup OBJECT-TYPE + SYNTAX GlobalOutletStateOnStartupEnumeration + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The outlet state on device startup; applies to all outlets + unless overridden at the outlet level. + Note that this value is ignored if relayBehaviorOnPowerLoss is set to latching." + ::= { unitConfigurationEntry 38 } +outletPowerupSequence OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The sequence in which will the outlets will be switched on under the following conditions. + 1) Switch all outlets on operation is executed + 2) Power to the PDU is cycled + String must consist of a comma separated sequence of the outlet numbers and + all outlet numbers must be included. The numbers entered must be a permutation of the numbers + 1,2,3,-outletnumber. + Example for a 12 outlet PDU: 1,12,3,5,6,7,10,2,4,11,9,8. -globalOutletStateOnStartup OBJECT-TYPE - SYNTAX GlobalOutletStateOnStartupEnumeration - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The outlet state on device startup; applies to all outlets - unless overridden at the outlet level. - Note that this value is ignored if relayBehaviorOnPowerLoss is set to latching." - ::= { unitConfigurationEntry 38 } + The per outlet sequence delays are defined as outletSequenceDelay in the outletConfigurationTable" + ::= { unitConfigurationEntry 39 } -outletPowerupSequence OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The sequence in which will the outlets will be switched on under the following conditions. - 1) Switch all outlets on operation is executed - 2) Power to the PDU is cycled - String must consist of a comma separated sequence of the outlet numbers and - all outlet numbers must be included. The numbers entered must be a permutation of the numbers - 1,2,3,-outletnumber. - Example for a 12 outlet PDU: 1,12,3,5,6,7,10,2,4,11,9,8. +pduPowerCyclingPowerOffPeriod OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "When power to the PX is cycled (either manually or because of a + temporary power loss), this number determines how many seconds the + PX will wait before it provides power to the outlets. + specified in seconds: + 1 <= value <= 3600 seconds. + Note that this value is ignored if relayBehaviorOnPowerLoss is set to latching." + ::= { unitConfigurationEntry 40 } - The per outlet sequence delays are defined as outletSequenceDelay in the outletConfigurationTable - " - ::= { unitConfigurationEntry 39 } +pduDaisychainMemberType OBJECT-TYPE + SYNTAX DaisychainMemberTypeEnumeration + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The daisy chain member type." + ::= { unitConfigurationEntry 41 } +managedExternalSensorCount OBJECT-TYPE + SYNTAX Integer32(0..255) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of managed external sensors" + ::= { unitConfigurationEntry 42 } -pduPowerCyclingPowerOffPeriod OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "When power to the PX is cycled (either manually or because of a - temporary power loss), this number determines how many seconds the - PX will wait before it provides power to the outlets. - specified in seconds: - 0 <= value <= 3600 seconds. - Note that this value is ignored if relayBehaviorOnPowerLoss is set to latching." - ::= { unitConfigurationEntry 40 } +pxInetAddressType OBJECT-TYPE + SYNTAX InetAddressType + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The type of address format + This object is deprecated in favor of ipAddressTable from the IP-MIB (rfc4293)." + ::= { unitConfigurationEntry 50 } +pxInetIPAddress OBJECT-TYPE + SYNTAX InetAddress + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The current IP address. A value of 0.0.0.0 indicates an error + or an unset option. + This object is deprecated in favor of ipAddressTable from the IP-MIB (rfc4293). + For IPv6, its value is 0.0.0.0" + ::= { unitConfigurationEntry 51 } -pduDaisychainMemberType OBJECT-TYPE - SYNTAX DaisychainMemberTypeEnumeration - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The daisy chain member type." - ::= { unitConfigurationEntry 41 } +pxInetNetmask OBJECT-TYPE + SYNTAX InetAddress + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The current netmask. A value of 0.0.0.0 indicates an error + or an unset option. + This object is deprecated in favor of ipAddressTable from the IP-MIB (rfc4293). + For IPv6, its value is 0.0.0.0" + ::= { unitConfigurationEntry 52 } +pxInetGateway OBJECT-TYPE + SYNTAX InetAddress + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The current gateway. A value of 0.0.0.0 indicates an error + or an unset option. + This object is deprecated in favor of ipAddressTable from the IP-MIB (rfc4293). + For IPv6, its value is 0.0.0.0" + ::= { unitConfigurationEntry 53 } -managedExternalSensorCount OBJECT-TYPE - SYNTAX Integer32(0..255) - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The number of managed external sensors " - ::= { unitConfigurationEntry 42 } +loadShedding OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enter/Exit Load Shedding Mode" + ::= { unitConfigurationEntry 55 } +serverCount OBJECT-TYPE + SYNTAX Integer32(0..255) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of servers monitored with the server reachability feature" + ::= { unitConfigurationEntry 56 } -pxInetAddressType OBJECT-TYPE - SYNTAX InetAddressType - MAX-ACCESS read-only - STATUS deprecated - DESCRIPTION - "The type of address format - This object is deprecated in favor of ipAddressTable from the IP-MIB (rfc4293)." - ::= { unitConfigurationEntry 50 } - - -pxInetIPAddress OBJECT-TYPE - SYNTAX InetAddress - MAX-ACCESS read-only - STATUS deprecated - DESCRIPTION - "The current IP address. A value of 0.0.0.0 indicates an error - or an unset option. - This object is deprecated in favor of ipAddressTable from the IP-MIB (rfc4293). - For IPv6, its value is 0.0.0.0 " - ::= { unitConfigurationEntry 51 } - -pxInetNetmask OBJECT-TYPE - SYNTAX InetAddress - MAX-ACCESS read-only - STATUS deprecated - DESCRIPTION - "The current netmask. A value of 0.0.0.0 indicates an error - or an unset option. - This object is deprecated in favor of ipAddressTable from the IP-MIB (rfc4293). - For IPv6, its value is 0.0.0.0 " - ::= { unitConfigurationEntry 52 } - - -pxInetGateway OBJECT-TYPE - SYNTAX InetAddress - MAX-ACCESS read-only - STATUS deprecated - DESCRIPTION - "The current gateway. A value of 0.0.0.0 indicates an error - or an unset option. - This object is deprecated in favor of ipAddressTable from the IP-MIB (rfc4293). - For IPv6, its value is 0.0.0.0 " - ::= { unitConfigurationEntry 53 } - -loadShedding OBJECT-TYPE - SYNTAX TruthValue - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "Enter/Exit Load Shedding Mode" - ::= { unitConfigurationEntry 55 } - - -serverCount OBJECT-TYPE - SYNTAX Integer32(0..255) - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The number of servers" - ::= { unitConfigurationEntry 56 } - - -inrushGuardDelay OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The time interval between switching on two outlets; - specified in milliseconds; - 100 <= value <= 100000 milliseconds." - ::= { unitConfigurationEntry 57 } - - -cascadedDeviceConnected OBJECT-TYPE - SYNTAX TruthValue - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "Indicates whether another PX2 is connected using an USB cable to - the USB-A port of this PX2 in a cascaded configuration. - true: Connected - false: Not Connected" - ::= { unitConfigurationEntry 58 } - +inrushGuardDelay OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The time interval between switching on two outlets; + specified in milliseconds; + 100 <= value <= 100000 milliseconds." + ::= { unitConfigurationEntry 57 } +cascadedDeviceConnected OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates whether another PX2 is connected using an USB cable to + the USB-A port of this PX2 in a cascaded configuration." + ::= { unitConfigurationEntry 58 } synchronizeWithNTPServer OBJECT-TYPE - SYNTAX TruthValue - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "Will time be obtained using NTP? - true: time will be obtained using NTP servers - false: time will not be obtained using NTP servers - Deafault is false." - - ::= { unitConfigurationEntry 59 } + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Indicates whether time is synchronized with an NTP server." + ::= { unitConfigurationEntry 59 } useDHCPProvidedNTPServer OBJECT-TYPE - SYNTAX TruthValue - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "Will the NTP server addresses be provided by DHCP/BOOTP? - This is used only if synchronizeWithNTPServer is enabled - Default is enabled, i.e. DHCP provided NTP servers will be used " - - ::= { unitConfigurationEntry 60 } + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS obsolete + DESCRIPTION + "**NOTE: This object is obsolete. Its functionality has been replaced + by the following: + - If at least one of firstNTPServerAddress and secondNTPServerAddress + has been configured then use the static NTP servers + - else use the DHCP-provided NTP servers" + ::= { unitConfigurationEntry 60 } firstNTPServerAddressType OBJECT-TYPE - SYNTAX InetAddressType - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "Represents the type of the corresponding instance - of firstNTPServerAddress object." - DEFVAL { ipv4 } - ::= { unitConfigurationEntry 61 } - -firstNTPServerAddress OBJECT-TYPE - SYNTAX InetAddress - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The address of the primary ntp server." - ::= { unitConfigurationEntry 62 } + SYNTAX InetAddressType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Represents the type of the corresponding instance + of firstNTPServerAddress object. When setting this value, + be sure that firstNTPServerAddress is of this address type, + e.g. by setting both of them." + DEFVAL { ipv4 } + ::= { unitConfigurationEntry 61 } +firstNTPServerAddress OBJECT-TYPE + SYNTAX InetAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The address of the primary NTP server. + When setting this value, be sure that it + is of the type specified in firstNTPServerAddressType, + e.g. by setting both of them." + ::= { unitConfigurationEntry 62 } secondNTPServerAddressType OBJECT-TYPE - SYNTAX InetAddressType - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "Represents the type of the corresponding instance - of secondNTPServerAddress object. - Default is ipv4" - - ::= { unitConfigurationEntry 63 } + SYNTAX InetAddressType + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Represents the type of the corresponding instance + of secondNTPServerAddress object. When setting this value, + be sure that secondNTPServerAddress is of this address type, + e.g. by setting both of them. + Default is ipv4" + ::= { unitConfigurationEntry 63 } -secondNTPServerAddress OBJECT-TYPE - SYNTAX InetAddress - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The address of the second ntp server." - ::= { unitConfigurationEntry 64 } +secondNTPServerAddress OBJECT-TYPE + SYNTAX InetAddress + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The address of the second NTP server. + When setting this value, be sure that it + is of the type specified in secondNTPServerAddressType, + e.g. by setting both of them." + ::= { unitConfigurationEntry 64 } -wireCount OBJECT-TYPE - SYNTAX Integer32(0..255) - MAX-ACCESS read-only - STATUS deprecated - DESCRIPTION - "The number of wires." - ::= { unitConfigurationEntry 65 } +wireCount OBJECT-TYPE + SYNTAX Integer32(0..255) + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The number of wire objects in the PDU topology. This feature is no + longer used, the returned value is always 0." + ::= { unitConfigurationEntry 65 } -transferSwitchCount OBJECT-TYPE - SYNTAX Integer32(0..255) - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The number of transfer switches." - ::= { unitConfigurationEntry 66 } +transferSwitchCount OBJECT-TYPE + SYNTAX Integer32(0..255) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of transfer switches." + ::= { unitConfigurationEntry 66 } +productType OBJECT-TYPE + SYNTAX ProductTypeEnumeration + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The product type (PDU, BCM, transfer switch or power meter)." + ::= { unitConfigurationEntry 67 } -productType OBJECT-TYPE - SYNTAX ProductTypeEnumeration - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The product type. - Is this product a PDU, STS, BCM,...? - " - ::= { unitConfigurationEntry 67} +meteringControllerCount OBJECT-TYPE + SYNTAX Integer32(0..255) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of metering controllers." + ::= { unitConfigurationEntry 68 } +relayBehaviorOnPowerLoss OBJECT-TYPE + SYNTAX RelayPowerLossBehaviorEnumeration + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The relay behavior on power loss (latching or non-latching)." + ::= { unitConfigurationEntry 69 } -meteringControllerCount OBJECT-TYPE - SYNTAX Integer32(0..255) - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The number of metering controllers." - ::= { unitConfigurationEntry 68 } +deviceCascadeType OBJECT-TYPE + SYNTAX DeviceCascadeTypeEnumeration + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The type of network cascade this device is part of (none, bridging + or port forwarding)." + ::= { unitConfigurationEntry 70 } -relayBehaviorOnPowerLoss OBJECT-TYPE - SYNTAX RelayPowerLossBehaviorEnumeration - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The relay behavior on power loss." - ::= { unitConfigurationEntry 69} - -deviceCascadeType OBJECT-TYPE - SYNTAX DeviceCascadeTypeEnumeration - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The configured type of cascading: - default is bridging. - This can be set only if the unit is the master." - ::= { unitConfigurationEntry 70} - -deviceCascadePosition OBJECT-TYPE - SYNTAX Integer32(0..99) - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The position of the device in the cascaded chain. - 0: master - >= 1: slaves " - ::= { unitConfigurationEntry 71 } +deviceCascadePosition OBJECT-TYPE + SYNTAX Integer32(0..99) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The position of the device in the cascade chain. Only supported in + port forwarding mode, 0 otherwise." + ::= { unitConfigurationEntry 71 } peripheralDevicesAutoManagement OBJECT-TYPE - SYNTAX TruthValue - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "Auto-management enabled state for peripheral devices." - ::= { unitConfigurationEntry 72} + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Defines whether newly-connected peripheral devices are automatically + assigned to an unused slot." + ::= { unitConfigurationEntry 72 } -frontPanelOutletSwitching OBJECT-TYPE - SYNTAX TruthValue - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "Enables/disables switching of outlets using the PDU front panel." - ::= { unitConfigurationEntry 73} +frontPanelOutletSwitching OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables/disables switching of outlets using the PDU front panel." + ::= { unitConfigurationEntry 73 } -frontPanelRCMSelfTest OBJECT-TYPE - SYNTAX TruthValue - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "Enables/disables front panel RCM self-test." - ::= { unitConfigurationEntry 74} +frontPanelRCMSelfTest OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables/disables front panel RCM self-test." + ::= { unitConfigurationEntry 74 } -frontPanelActuatorControl OBJECT-TYPE - SYNTAX TruthValue - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "Enables/disables front panel peripheral actuator control." - ::= { unitConfigurationEntry 75} +frontPanelActuatorControl OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables/disables front panel peripheral actuator control." + ::= { unitConfigurationEntry 75 } --- The ControllerConfiguration table contains information on the controllers in the PDU +circuitCount OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of branch circuits in a panel." + ::= { unitConfigurationEntry 76 } +activeDNSServerCount OBJECT-TYPE + SYNTAX Integer32(0..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of active DNS servers" + ::= { unitConfigurationEntry 77 } -controllerConfigurationTable OBJECT-TYPE - SYNTAX SEQUENCE OF ControllerConfigurationEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A list of entries for the boards in each PDU. The number of - entries is given by the value of - inletControllerCount + outletControllerCount + 1 (for main controller board)." - ::= { unit 3} +activeNTPServerCount OBJECT-TYPE + SYNTAX Integer32(0..16) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of active NTP servers" + ::= { unitConfigurationEntry 78 } -controllerConfigurationEntry OBJECT-TYPE - SYNTAX ControllerConfigurationEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "An entry containing objects for a controller." - INDEX { pduId, boardType, boardIndex } - ::= { controllerConfigurationTable 1 } +-- activeDNSServerTable: information about active DNS servers -ControllerConfigurationEntryStruct ::= SEQUENCE { - boardType BoardTypeEnumeration, - boardIndex Integer32, - boardVersion DisplayString, - boardFirmwareVersion DisplayString, - boardFirmwareTimeStamp Unsigned32 - } +activeDNSServerTable OBJECT-TYPE + SYNTAX SEQUENCE OF ActiveDNSServerEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of active DNS server entries. The number of rows in the table is + given by the value of activeDNSServerCount in unitConfigurationTable." + ::= { unit 6 } +activeDNSServerEntry OBJECT-TYPE + SYNTAX ActiveDNSServerEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing an active DNS server for a particular PDU." + INDEX { pduId, activeDNSServerIndex } + ::= { activeDNSServerTable 1 } +ActiveDNSServerEntryStruct ::= SEQUENCE { + activeDNSServerIndex Integer32, + activeDNSServerAddressType InetAddressType, + activeDNSServerAddress InetAddress, + activeDNSServerAddressSource AddressSourceEnumeration + } -boardType OBJECT-TYPE - SYNTAX BoardTypeEnumeration - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "The type of board." - ::= { controllerConfigurationEntry 1 } +activeDNSServerIndex OBJECT-TYPE + SYNTAX Integer32(1..16) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A unique value for a DNS server. Its value ranges between 1 and activeDNSServerCount." + ::= { activeDNSServerEntry 2 } -boardIndex OBJECT-TYPE - SYNTAX Integer32(1..256) - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A unique value for each controller. Its value - ranges between 1 and the value of - inletControllerCount + outletControllerCount + 1." - ::= { controllerConfigurationEntry 2 } +activeDNSServerAddressType OBJECT-TYPE + SYNTAX InetAddressType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Represents the type of the corresponding instance + of activeDNSServerAddress object." + ::= { activeDNSServerEntry 3 } -boardVersion OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The board hardware version." - ::= { controllerConfigurationEntry 4 } +activeDNSServerAddress OBJECT-TYPE + SYNTAX InetAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The address of the DNS server." + ::= { activeDNSServerEntry 4 } -boardFirmwareVersion OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The firmware version." - ::= { controllerConfigurationEntry 6 } +activeDNSServerAddressSource OBJECT-TYPE + SYNTAX AddressSourceEnumeration + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "How was the address obtained: static, DHCP, DHCPv6? + No longer used, always set to static." + ::= { activeDNSServerEntry 5 } -boardFirmwareTimeStamp OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The time when the board firmware was updated in UNIX(epoch)time. - It is measured in seconds relative to January 1, 1970 (midnight UTC/GMT), - i.e a value of 0 indicates January 1, 1970 (midnight UTC/GMT)." - ::= { controllerConfigurationEntry 8 } +-- activeNTPServerTable: information about active NTP servers +activeNTPServerTable OBJECT-TYPE + SYNTAX SEQUENCE OF ActiveNTPServerEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of active NTP server entries. The number of rows in the table is + given by the value of activeNTPServerCount in unitConfigurationTable." + ::= { unit 7 } +activeNTPServerEntry OBJECT-TYPE + SYNTAX ActiveNTPServerEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing an active NTP server for a particular PDU." + INDEX { pduId, activeNTPServerIndex } + ::= { activeNTPServerTable 1 } --- The LogConfiguration table contains information on the logs in the PDU. +ActiveNTPServerEntryStruct ::= SEQUENCE { + activeNTPServerIndex Integer32, + activeNTPServerAddressType InetAddressType, + activeNTPServerAddress InetAddress, + activeNTPServerAddressSource AddressSourceEnumeration + } +activeNTPServerIndex OBJECT-TYPE + SYNTAX Integer32(1..16) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A unique value for an NTP server. Its value ranges between 1 and activeNTPServerCount." + ::= { activeNTPServerEntry 2 } -logConfigurationTable OBJECT-TYPE - SYNTAX SEQUENCE OF LogConfigurationEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A table of parameters for the data logging feature. The number of - entries is given by the value of pduCount." - ::= { unit 4} +activeNTPServerAddressType OBJECT-TYPE + SYNTAX InetAddressType + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Represents the type of the corresponding instance + of activeNTPServerAddress object, e.g. IPv4, IPv6, DNS Name" + ::= { activeNTPServerEntry 3 } -logConfigurationEntry OBJECT-TYPE - SYNTAX LogConfigurationEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "An entry containing data logging parameters - for a particular PDU." - INDEX { pduId } - ::= { logConfigurationTable 1 } +activeNTPServerAddress OBJECT-TYPE + SYNTAX InetAddress + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The address of the NTP server." + ::= { activeNTPServerEntry 4 } -LogConfigurationEntryStruct ::= SEQUENCE { - dataLogging TruthValue, - measurementPeriod Integer32, - measurementsPerLogEntry Integer32, - logSize Integer32, - dataLoggingEnableForAllSensors TruthValue - } +activeNTPServerAddressSource OBJECT-TYPE + SYNTAX AddressSourceEnumeration + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "How was the address obtained: static, DHCP, DHCPv6? + No longer used, always set to static." + ::= { activeNTPServerEntry 5 } +-- controllerConfigurationTable: information about the controllers in a PDU -dataLogging OBJECT-TYPE - SYNTAX TruthValue - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "Data Retrieval: enabled/disabled." - ::= { logConfigurationEntry 1 } +controllerConfigurationTable OBJECT-TYPE + SYNTAX SEQUENCE OF ControllerConfigurationEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of entries for the boards in a PDU. The number of entries is + one more than the sum of inletControllerCount, outletControllerCount + and meterControllerCount." + ::= { unit 3 } -measurementPeriod OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "Data Collection periodicity. This is the periodicity of the data collected by the PX. - This value is fixed at 1 second." - ::= { logConfigurationEntry 2 } +controllerConfigurationEntry OBJECT-TYPE + SYNTAX ControllerConfigurationEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing objects for a controller." + INDEX { pduId, boardType, boardIndex } + ::= { controllerConfigurationTable 1 } +ControllerConfigurationEntryStruct ::= SEQUENCE { + boardType BoardTypeEnumeration, + boardIndex Integer32, + boardVersion DisplayString, + boardFirmwareVersion DisplayString, + boardFirmwareTimeStamp Unsigned32 + } -measurementsPerLogEntry OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The number of measurements used for each entry in the log." - ::= { logConfigurationEntry 3 } +boardType OBJECT-TYPE + SYNTAX BoardTypeEnumeration + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The type of board." + ::= { controllerConfigurationEntry 1 } -logSize OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The number of entries in the log." - ::= { logConfigurationEntry 4 } +boardIndex OBJECT-TYPE + SYNTAX Integer32(1..256) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A unique value for each controller." + ::= { controllerConfigurationEntry 2 } +boardVersion OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The board hardware version." + ::= { controllerConfigurationEntry 4 } -dataLoggingEnableForAllSensors OBJECT-TYPE - SYNTAX TruthValue - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "Operation to control data logging for all sensors. - If this OID is set to true, then all xxxSensorLogAvailable are set to true - If this OID is set to false, then all xxxSensorLogAvailable are set to false +boardFirmwareVersion OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The firmware version." + ::= { controllerConfigurationEntry 6 } - " - ::= { logConfigurationEntry 5 } +boardFirmwareTimeStamp OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time when the board firmware was updated as UNIX timestamp. + It is measured in seconds since January 1, 1970 (midnight UTC/GMT)" + ::= { controllerConfigurationEntry 8 } +-- logConfigurationTable: information and configuration for the sensor data log +logConfigurationTable OBJECT-TYPE + SYNTAX SEQUENCE OF LogConfigurationEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table of parameters for the data logging feature. The number of + entries is given by the value of pduCount." + ::= { unit 4 } --- the TrapInformation +logConfigurationEntry OBJECT-TYPE + SYNTAX LogConfigurationEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing data logging parameters for a particular PDU." + INDEX { pduId } + ::= { logConfigurationTable 1 } --- The TrapInformation table defines information sent in the traps. +LogConfigurationEntryStruct ::= SEQUENCE { + dataLogging TruthValue, + measurementPeriod Integer32, + measurementsPerLogEntry Integer32, + logSize Integer32, + dataLoggingEnableForAllSensors TruthValue + } +dataLogging OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Defines whether sensor data logging is enabled." + ::= { logConfigurationEntry 1 } +measurementPeriod OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Data collection periodicity. This is the periodicity of the data + collected by the PDU. This value is fixed at 1 second." + ::= { logConfigurationEntry 2 } -trapInformationTable OBJECT-TYPE - SYNTAX SEQUENCE OF TrapInformationEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A list of Trap Information entries. The number of - entries is given by the value of pduCount." - ::= { trapInformation 1 } +measurementsPerLogEntry OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The number of measurements aggregated into a data log entry." + ::= { logConfigurationEntry 3 } -trapInformationEntry OBJECT-TYPE - SYNTAX TrapInformationEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "An entry containing objects used in traps." - INDEX { pduId } - ::= { trapInformationTable 1 } +logSize OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The capacity (number of entries) of the data log." + ::= { logConfigurationEntry 4 } -TrapInformationEntryStruct ::= SEQUENCE { - userName DisplayString, - targetUser DisplayString, - imageVersion DisplayString, - roleName DisplayString, - smtpMessageRecipients DisplayString, - smtpServer DisplayString - } +dataLoggingEnableForAllSensors OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Operation to control data logging for all sensors: + - when set to true, all *SensorLogAvailable OIDs are set to true + - when set to false, all *SensorLogAvailable OIDs are set to false" + ::= { logConfigurationEntry 5 } +-- Information objects used exclusively in traps +trapInformationTable OBJECT-TYPE + SYNTAX SEQUENCE OF TrapInformationEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A group of objects used exclusively in traps. This is a table for + historic reasons; it can't be queried from the SNMP agent." + ::= { trapInformation 1 } -userName OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The user currently logged in." - ::= { trapInformationEntry 2 } +trapInformationEntry OBJECT-TYPE + SYNTAX TrapInformationEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing objects used in traps." + INDEX { pduId } + ::= { trapInformationTable 1 } -targetUser OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The user added, deleted, or modified." - ::= { trapInformationEntry 3 } +TrapInformationEntryStruct ::= SEQUENCE { + userName DisplayString, + targetUser DisplayString, + imageVersion DisplayString, + roleName DisplayString, + smtpMessageRecipients DisplayString, + smtpServer DisplayString + } +userName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The user currently logged in." + ::= { trapInformationEntry 2 } -imageVersion OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The version of the upgrade image." - ::= { trapInformationEntry 5 } - -roleName OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The role added, deleted, or modified." - ::= { trapInformationEntry 6 } - - -smtpMessageRecipients OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "Comma separated list of SMTP Message recipients" - ::= { trapInformationEntry 7 } - - -smtpServer OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The IP address/host name of the SMTP server" - ::= { trapInformationEntry 8 } +targetUser OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The user added, deleted, or modified." + ::= { trapInformationEntry 3 } +imageVersion OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The version of the upgrade image." + ::= { trapInformationEntry 5 } +roleName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The role added, deleted, or modified." + ::= { trapInformationEntry 6 } +smtpMessageRecipients OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Comma separated list of SMTP message recipients" + ::= { trapInformationEntry 7 } +smtpServer OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The IP address/host name of the SMTP server" + ::= { trapInformationEntry 8 } -- Additional Information needed for traps. +oldSensorState OBJECT-TYPE + SYNTAX SensorStateEnumeration + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "The old sensor state used in sensor state transition traps." + ::= { trapInformation 2 } +pduNumber OBJECT-TYPE + SYNTAX Integer32(1..256) + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "A unique value for each PDU. Its value ranges between 1 and the + value of pduCount." + ::= { trapInformation 3 } -oldSensorState OBJECT-TYPE - SYNTAX SensorStateEnumeration - MAX-ACCESS accessible-for-notify - STATUS current - DESCRIPTION - "The old sensor state used in Sensor State Transition traps." - ::= { trapInformation 2} +inletPoleNumber OBJECT-TYPE + SYNTAX Integer32(1..256) + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "A unique value for each inlet pole. Its value ranges between 1 + and the value of inletPoleCount." + ::= { trapInformation 5 } -pduNumber OBJECT-TYPE - SYNTAX Integer32(1..256) - MAX-ACCESS accessible-for-notify - STATUS current - DESCRIPTION - "A unique value for each PDU. Its value - ranges between 1 and the value of pduCount." - ::= { trapInformation 3 } +outletPoleNumber OBJECT-TYPE + SYNTAX Integer32(1..256) + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "A unique value for each outlet pole. Its value ranges between 1 + and the value of outletPoleCount." + ::= { trapInformation 7 } +externalSensorNumber OBJECT-TYPE + SYNTAX Integer32(1..256) + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "A unique value for each external sensor. Its value ranges between 1 + and the value of externalSensorCount." + ::= { trapInformation 8 } +typeOfSensor OBJECT-TYPE + SYNTAX SensorTypeEnumeration + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "The type of sensor." + ::= { trapInformation 10 } +errorDescription OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "Description of the error" + ::= { trapInformation 11 } -inletPoleNumber OBJECT-TYPE - SYNTAX Integer32(1..256) - MAX-ACCESS accessible-for-notify - STATUS current - DESCRIPTION - "A unique value for each inlet Pole. Its value - ranges between 1 and the value of inletPoleCount." - ::= { trapInformation 5 } +deviceChangedParameter OBJECT-TYPE + SYNTAX DeviceIdentificationParameterEnumeration + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "Identifies the parameter that has changed." + ::= { trapInformation 12 } +changedParameterNewValue OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "The new value of the changed parameter" + ::= { trapInformation 13 } +lhxSupportEnabled OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "The new enabled state for Schroff LHX support." + ::= { trapInformation 14 } +webcamModel OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "The model of the webcam" + ::= { trapInformation 15 } +webcamConnectionPort OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "The port to which the webcam is connected" + ::= { trapInformation 16 } -outletPoleNumber OBJECT-TYPE - SYNTAX Integer32(1..256) - MAX-ACCESS accessible-for-notify - STATUS current - DESCRIPTION - "A unique value for each outlet Pole. Its value - ranges between 1 and the value of outletPoleCount." - ::= { trapInformation 7 } - - - -externalSensorNumber OBJECT-TYPE - SYNTAX Integer32(1..256) - MAX-ACCESS accessible-for-notify - STATUS current - DESCRIPTION - "A unique value for each external sensor. Its value - ranges between 1 and the value of externalSensorCount." - ::= { trapInformation 8 } - - - - - -typeOfSensor OBJECT-TYPE - SYNTAX SensorTypeEnumeration - MAX-ACCESS accessible-for-notify - STATUS current - DESCRIPTION - "The type of sensor." - ::= { trapInformation 10 } - - -errorDescription OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS accessible-for-notify - STATUS current - DESCRIPTION - "Description of the Error" - ::= { trapInformation 11 } - - -deviceChangedParameter OBJECT-TYPE - SYNTAX DeviceIdentificationParameterEnumeration - MAX-ACCESS accessible-for-notify - STATUS current - DESCRIPTION - "Description of the parameter(s) that changed. - " - ::= { trapInformation 12 } - - -changedParameterNewValue OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS accessible-for-notify - STATUS current - DESCRIPTION - "The new value of the changed parameter " - ::= { trapInformation 13 } - - -lhxSupportEnabled OBJECT-TYPE - SYNTAX TruthValue - MAX-ACCESS accessible-for-notify - STATUS current - DESCRIPTION - "The new enabled state for Schroff LHX Support." - ::= { trapInformation 14 } - - - -webcamModel OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS accessible-for-notify - STATUS current - DESCRIPTION - "The model of the Webcam " - ::= { trapInformation 15 } - - -webcamConnectionPort OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS accessible-for-notify - STATUS current - DESCRIPTION - "The port to which the Webcam is connected " - ::= { trapInformation 16 } - -agentInetPortNumber OBJECT-TYPE - SYNTAX InetPortNumber - MAX-ACCESS accessible-for-notify - STATUS current - DESCRIPTION - "The UDP port number used for accessing - the SNMP agent on the device. - Examples: - If deviceCascadeType is portForwarding, then - master: 50500 - slave 1:50501 - slave 2: 50502 - ...... - If cascading mode is not portForwarding and default (Standard) ports are being used, then - port: 161 - - " - ::= { trapInformation 18 } - -peripheralDeviceRomcode OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS accessible-for-notify - STATUS current - DESCRIPTION - "The Romcode of an peripheral device" - ::= { trapInformation 19 } +agentInetPortNumber OBJECT-TYPE + SYNTAX InetPortNumber + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "The UDP port number used for accessing the SNMP agent on the device. + This is necessary to identify the slave in a port forwarding cascade." + ::= { trapInformation 18 } +peripheralDeviceRomcode OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "The 1-wire romcode of a peripheral device" + ::= { trapInformation 19 } peripheralDeviceFirmwareUpdateState OBJECT-TYPE - SYNTAX PeripheralDeviceFirmwareUpdateStateEnumeration - MAX-ACCESS accessible-for-notify - STATUS current - DESCRIPTION - "The firmware update state of an peripheral device" - ::= { trapInformation 20 } + SYNTAX PeripheralDeviceFirmwareUpdateStateEnumeration + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "The firmware update state of a peripheral device" + ::= { trapInformation 20 } +circuitNumber OBJECT-TYPE + SYNTAX Integer32(1..33000) + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "A unique value for each circuit. Defined as follows: + circuitNumber = 1000 * panelId + circuitPosition --- the unitSensorConfiguration table + Examples: + 1045 is the the circuit on panel 1 with lowest circuit position equal to 45 + 4067 is the the circuit on panel 4 with lowest circuit position equal to 67." + ::= { trapInformation 21 } --- The unitSensorConfiguration table contains information on the PDU's unit Sensors. +circuitPoleNumber OBJECT-TYPE + SYNTAX Integer32(1..256) + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "A unique value for each circuit pole." + ::= { trapInformation 22 } +phoneNumber OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "The phone number of e.g. an SMS receiver." + ::= { trapInformation 23 } -unitSensorConfigurationTable OBJECT-TYPE - SYNTAX SEQUENCE OF UnitSensorConfigurationEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A list of unit level sensors for a PDU." - ::= { unit 5 } +smartCardReaderId OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "The ID of a smartcard reader." + ::= { trapInformation 24 } -unitSensorConfigurationEntry OBJECT-TYPE - SYNTAX UnitSensorConfigurationEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "An entry containing unit sensor parameters." - INDEX { pduId, sensorType } - ::= { unitSensorConfigurationTable 1 } +smartCardTimestamp OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "The timestamp indicating when the smartcard was inserted or removed. + It is measured in seconds since January 1, 1970 UTC" + ::= { trapInformation 25 } -UnitSensorConfigurationEntryStruct ::= SEQUENCE {sensorType SensorTypeEnumeration, - unitSensorLogAvailable TruthValue, - unitSensorUnits SensorUnitsEnumeration, - unitSensorDecimalDigits Unsigned32, - unitSensorAccuracy HundredthsOfAPercentage, - unitSensorResolution Unsigned32, - unitSensorTolerance Unsigned32, - unitSensorMaximum Unsigned32, - unitSensorMinimum Unsigned32, - unitSensorHysteresis Unsigned32, - unitSensorStateChangeDelay Unsigned32, - unitSensorLowerCriticalThreshold Unsigned32, - unitSensorLowerWarningThreshold Unsigned32, - unitSensorUpperCriticalThreshold Unsigned32, - unitSensorUpperWarningThreshold Unsigned32, - unitSensorEnabledThresholds BITS, - unitSensorSignedMaximum Integer32, - unitSensorSignedMinimum Integer32, - unitSensorSignedLowerCriticalThreshold Integer32, - unitSensorSignedLowerWarningThreshold Integer32, - unitSensorSignedUpperCriticalThreshold Integer32, - unitSensorSignedUpperWarningThreshold Integer32 - } +smartCardType OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "The type of a smartcard." + ::= { trapInformation 26 } -sensorType OBJECT-TYPE - SYNTAX SensorTypeEnumeration - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "The type of sensor." - ::= { unitSensorConfigurationEntry 1 } +smartCardId OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "The ID/serial number of a smartcard." + ::= { trapInformation 27 } -unitSensorLogAvailable OBJECT-TYPE - SYNTAX TruthValue - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "Is logging enabled for the sensor?" - ::= { unitSensorConfigurationEntry 4 } +suspectedTripCauseLabel OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS accessible-for-notify + STATUS current + DESCRIPTION + "The label of the outlet that likely caused the OCP trip, + if it can be determined." + ::= { trapInformation 28 } -unitSensorUnits OBJECT-TYPE - SYNTAX SensorUnitsEnumeration - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The units in which the sensor data is reported. - " - ::= { unitSensorConfigurationEntry 6 } +-- unitSensorConfigurationTable: information and settings for unit-level sensors -unitSensorDecimalDigits OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The number of digits displayed to the right of the decimal point." - ::= { unitSensorConfigurationEntry 7 } +unitSensorConfigurationTable OBJECT-TYPE + SYNTAX SEQUENCE OF UnitSensorConfigurationEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of unit-level sensors for a PDU." + ::= { unit 5 } -unitSensorAccuracy OBJECT-TYPE - SYNTAX HundredthsOfAPercentage - MAX-ACCESS read-only - STATUS deprecated - DESCRIPTION - "The accuracy: how close (in percent) the measurement is to the actual value." - ::= { unitSensorConfigurationEntry 8 } +unitSensorConfigurationEntry OBJECT-TYPE + SYNTAX UnitSensorConfigurationEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing unit sensor parameters." + INDEX { pduId, sensorType } + ::= { unitSensorConfigurationTable 1 } +UnitSensorConfigurationEntryStruct ::= SEQUENCE { + sensorType SensorTypeEnumeration, + unitSensorLogAvailable TruthValue, + unitSensorUnits SensorUnitsEnumeration, + unitSensorDecimalDigits Unsigned32, + unitSensorAccuracy HundredthsOfAPercentage, + unitSensorResolution Unsigned32, + unitSensorTolerance Unsigned32, + unitSensorMaximum Unsigned32, + unitSensorMinimum Unsigned32, + unitSensorHysteresis Unsigned32, + unitSensorStateChangeDelay Unsigned32, + unitSensorLowerCriticalThreshold Unsigned32, + unitSensorLowerWarningThreshold Unsigned32, + unitSensorUpperCriticalThreshold Unsigned32, + unitSensorUpperWarningThreshold Unsigned32, + unitSensorEnabledThresholds BITS, + unitSensorSignedMaximum Integer32, + unitSensorSignedMinimum Integer32, + unitSensorSignedLowerCriticalThreshold Integer32, + unitSensorSignedLowerWarningThreshold Integer32, + unitSensorSignedUpperCriticalThreshold Integer32, + unitSensorSignedUpperWarningThreshold Integer32 + } -unitSensorResolution OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The resolution: the minimum difference between any two measured values - The value of this OID variable should be scaled by - unitSensorDecimalDigits. For example, if the value is 1 and - unitSensorDecimalDigits is 2, then actual value is 0.01." - ::= { unitSensorConfigurationEntry 9 } +sensorType OBJECT-TYPE + SYNTAX SensorTypeEnumeration + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "The type of sensor." + ::= { unitSensorConfigurationEntry 1 } -unitSensorTolerance OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS deprecated - DESCRIPTION - "The resolution: the difference between a sensor value and the actual value - The value of this OID variable should be scaled by - (unitSensorDecimalDigits + 1). For example, if the value is 50 and - unitSensorDecimalDigits is 2, then actual value is 0.05." - ::= { unitSensorConfigurationEntry 10 } +unitSensorLogAvailable OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is data logging enabled for the sensor?" + ::= { unitSensorConfigurationEntry 4 } -unitSensorMaximum OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The largest possible reading as an unsigned integer. - The value of this OID variable should be scaled by - unitSensorDecimalDigits. For example, if the value is 1 and - unitSensorDecimalDigits is 2, then actual value is 0.01. - The value is clamped if the scaled maximum exceeds 4294967295. It - is undefined for sensors which can have negative readings. - This parameter does not apply to sensors without numerical reading." - ::= { unitSensorConfigurationEntry 11 } +unitSensorUnits OBJECT-TYPE + SYNTAX SensorUnitsEnumeration + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The unit in which the sensor reading is reported. + This parameter does not apply to sensors without numerical reading." + ::= { unitSensorConfigurationEntry 6 } -unitSensorMinimum OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The smallest possible reading as an unsigned integer. - The value of this OID variable should be scaled by - unitSensorDecimalDigits. For example, if the value is 1 and - unitSensorDecimalDigits is 2, then actual value is 0.01. - The value is undefined for sensors which can have negative readings. - This parameter does not apply to sensors without numerical reading." - ::= { unitSensorConfigurationEntry 12 } +unitSensorDecimalDigits OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of digits displayed to the right of the decimal point." + ::= { unitSensorConfigurationEntry 7 } -unitSensorHysteresis OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The hysteresis used for deassertions - The value of this OID variable should be scaled by - unitSensorDecimalDigits. For example, if the value is 1 and - unitSensorDecimalDigits is 2, then actual value is 0.01. - This parameter does not apply to sensors without numerical reading." - ::= { unitSensorConfigurationEntry 13 } +unitSensorAccuracy OBJECT-TYPE + SYNTAX HundredthsOfAPercentage + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The accuracy: the maximum relative difference (in percent) between + measurement and the actual value. + This parameter does not apply to sensors without numerical reading." + ::= { unitSensorConfigurationEntry 8 } -unitSensorStateChangeDelay OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The delay measured in samples before a state is asserted. - If the value is zero, then the state is asserted as soon as - it is detected; if it is non-zero, say n, then the assertion - condition must exist for n+1 consecutive samples before the corresponding - assertion event is reported. - This parameter does not apply to sensors without numerical reading." - ::= { unitSensorConfigurationEntry 14 } +unitSensorResolution OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The resolution: the minimum difference between any two measured values + The value of this OID variable should be scaled by + unitSensorDecimalDigits. For example, if the value is 1 and + unitSensorDecimalDigits is 2, then actual value is 0.01. + This parameter does not apply to sensors without numerical reading." + ::= { unitSensorConfigurationEntry 9 } -unitSensorLowerCriticalThreshold OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The lower critical threshold as an unsigned integer. - The value of this OID variable should be scaled by - unitSensorDecimalDigits. For example, if the value is 1 and - unitSensorDecimalDigits is 2, then actual value is 0.01. - The value is clamped if the scaled threshold exceeds 4294967295. It - is undefined for sensors which can have negative readings. - This parameter does not apply to sensors without numerical reading." - ::= { unitSensorConfigurationEntry 21 } +unitSensorTolerance OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The tolerance: the maximum difference between measurement and the + actual value. The value of this OID variable should be scaled by + (unitSensorDecimalDigits + 1). For example, if the value is 50 and + unitSensorDecimalDigits is 2, then actual value is 0.05. + This parameter does not apply to sensors without numerical reading." + ::= { unitSensorConfigurationEntry 10 } -unitSensorLowerWarningThreshold OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The lower warning threshold as an unsigned integer. - The value of this OID variable should be scaled by - unitSensorDecimalDigits. For example, if the value is 1 and - unitSensorDecimalDigits is 2, then actual value is 0.01. - The value is clamped if the scaled threshold exceeds 4294967295. It - is undefined for sensors which can have negative readings. - This parameter does not apply to sensors without numerical reading." - ::= { unitSensorConfigurationEntry 22 } +unitSensorMaximum OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The largest possible reading as an unsigned integer. + The value of this OID variable should be scaled by + unitSensorDecimalDigits. For example, if the value is 1 and + unitSensorDecimalDigits is 2, then actual value is 0.01. + The value is clamped if the scaled maximum exceeds 4294967295. It + is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { unitSensorConfigurationEntry 11 } -unitSensorUpperCriticalThreshold OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The upper critical threshold as an unsigned integer. - The value of this OID variable should be scaled by - unitSensorDecimalDigits. For example, if the value is 1 and - unitSensorDecimalDigits is 2, then actual value is 0.01. - The value is clamped if the scaled threshold exceeds 4294967295. It - is undefined for sensors which can have negative readings. - This parameter does not apply to sensors without numerical reading." - ::= { unitSensorConfigurationEntry 23 } +unitSensorMinimum OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The smallest possible reading as an unsigned integer. + The value of this OID variable should be scaled by + unitSensorDecimalDigits. For example, if the value is 1 and + unitSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { unitSensorConfigurationEntry 12 } -unitSensorUpperWarningThreshold OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The upper warning threshold as an unsigned integer. - The value of this OID variable should be scaled by - unitSensorDecimalDigits. For example, if the value is 1 and - unitSensorDecimalDigits is 2, then actual value is 0.01. - The value is clamped if the scaled threshold exceeds 4294967295. It - is undefined for sensors which can have negative readings. - This parameter does not apply to sensors without numerical reading." - ::= { unitSensorConfigurationEntry 24 } +unitSensorHysteresis OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The hysteresis used when crossing a threshold towards the normal state. + The value of this OID variable should be scaled by + unitSensorDecimalDigits. For example, if the value is 1 and + unitSensorDecimalDigits is 2, then actual value is 0.01. + This parameter does not apply to sensors without numerical reading." + ::= { unitSensorConfigurationEntry 13 } -unitSensorEnabledThresholds OBJECT-TYPE - SYNTAX BITS { - lowerCritical(0), - lowerWarning(1), - upperWarning(2), - upperCritical(3) - } - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "A bit string which indicates which thresholds are enabled. - This parameter does not apply to sensors without numerical reading." - ::= { unitSensorConfigurationEntry 25 } +unitSensorStateChangeDelay OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The delay measured in samples before a state is asserted. + If the value is zero, then the state is asserted as soon as + it is detected; if it is non-zero, say n, then the assertion + condition must exist for n+1 consecutive samples before the + event is reported. + This parameter does not apply to sensors without numerical reading." + ::= { unitSensorConfigurationEntry 14 } -unitSensorSignedMaximum OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The largest possible reading as a signed integer. - The value of this OID variable should be scaled by - unitSensorDecimalDigits. For example, if the value is 1 and - unitSensorDecimalDigits is 2, then actual value is 0.01. - The value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647). - This parameter does not apply to sensors without numerical reading." - ::= { unitSensorConfigurationEntry 26 } +unitSensorLowerCriticalThreshold OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The lower critical threshold as an unsigned integer. + The value of this OID variable should be scaled by + unitSensorDecimalDigits. For example, if the value is 1 and + unitSensorDecimalDigits is 2, then actual value is 0.01. + The value is clamped if the scaled threshold exceeds 4294967295. It + is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { unitSensorConfigurationEntry 21 } -unitSensorSignedMinimum OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The smallest possible reading as a signed integer. - The value of this OID variable should be scaled by - unitSensorDecimalDigits. For example, if the value is 1 and - unitSensorDecimalDigits is 2, then actual value is 0.01. - This value determines whether to use the signed or unsigned threshold - and value columns: If the minimum is below zero the sensor can have - negative readings and the signed columns should be used. - This parameter does not apply to sensors without numerical reading." - ::= { unitSensorConfigurationEntry 27 } +unitSensorLowerWarningThreshold OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The lower warning threshold as an unsigned integer. + The value of this OID variable should be scaled by + unitSensorDecimalDigits. For example, if the value is 1 and + unitSensorDecimalDigits is 2, then actual value is 0.01. + The value is clamped if the scaled threshold exceeds 4294967295. It + is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { unitSensorConfigurationEntry 22 } + +unitSensorUpperCriticalThreshold OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The upper critical threshold as an unsigned integer. + The value of this OID variable should be scaled by + unitSensorDecimalDigits. For example, if the value is 1 and + unitSensorDecimalDigits is 2, then actual value is 0.01. + The value is clamped if the scaled threshold exceeds 4294967295. It + is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { unitSensorConfigurationEntry 23 } + +unitSensorUpperWarningThreshold OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The upper warning threshold as an unsigned integer. + The value of this OID variable should be scaled by + unitSensorDecimalDigits. For example, if the value is 1 and + unitSensorDecimalDigits is 2, then actual value is 0.01. + The value is clamped if the scaled threshold exceeds 4294967295. It + is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { unitSensorConfigurationEntry 24 } + +unitSensorEnabledThresholds OBJECT-TYPE + SYNTAX BITS { lowerCritical(0), + lowerWarning(1), + upperWarning(2), + upperCritical(3) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "A bit string indicating which thresholds are enabled. + This parameter does not apply to sensors without numerical reading." + ::= { unitSensorConfigurationEntry 25 } + +unitSensorSignedMaximum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The largest possible reading as a signed integer. + The value of this OID variable should be scaled by + unitSensorDecimalDigits. For example, if the value is 1 and + unitSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { unitSensorConfigurationEntry 26 } + +unitSensorSignedMinimum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The smallest possible reading as a signed integer. + The value of this OID variable should be scaled by + unitSensorDecimalDigits. For example, if the value is 1 and + unitSensorDecimalDigits is 2, then actual value is 0.01. + This value determines whether to use the signed or unsigned threshold + and value columns: If the minimum is below zero the sensor can have + negative readings and the signed columns should be used. + This parameter does not apply to sensors without numerical reading." + ::= { unitSensorConfigurationEntry 27 } unitSensorSignedLowerCriticalThreshold OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The lower critical threshold as a signed integer. - The value of this OID variable should be scaled by - unitSensorDecimalDigits. For example, if the value is 1 and - unitSensorDecimalDigits is 2, then actual value is 0.01. - The value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647). - This parameter does not apply to sensors without numerical reading." - ::= { unitSensorConfigurationEntry 28 } + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The lower critical threshold as a signed integer. + The value of this OID variable should be scaled by + unitSensorDecimalDigits. For example, if the value is 1 and + unitSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { unitSensorConfigurationEntry 28 } unitSensorSignedLowerWarningThreshold OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The lower warning threshold as a signed integer. - The value of this OID variable should be scaled by - unitSensorDecimalDigits. For example, if the value is 1 and - unitSensorDecimalDigits is 2, then actual value is 0.01. - The value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647). - This parameter does not apply to sensors without numerical reading." - ::= { unitSensorConfigurationEntry 29 } + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The lower warning threshold as a signed integer. + The value of this OID variable should be scaled by + unitSensorDecimalDigits. For example, if the value is 1 and + unitSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { unitSensorConfigurationEntry 29 } unitSensorSignedUpperCriticalThreshold OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The upper critical threshold as a signed integer. - The value of this OID variable should be scaled by - unitSensorDecimalDigits. For example, if the value is 1 and - unitSensorDecimalDigits is 2, then actual value is 0.01. - The value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647). - This parameter does not apply to sensors without numerical reading." - ::= { unitSensorConfigurationEntry 30 } + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The upper critical threshold as a signed integer. + The value of this OID variable should be scaled by + unitSensorDecimalDigits. For example, if the value is 1 and + unitSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { unitSensorConfigurationEntry 30 } unitSensorSignedUpperWarningThreshold OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The upper warning threshold as a signed integer. - The value of this OID variable should be scaled by - unitSensorDecimalDigits. For example, if the value is 1 and - unitSensorDecimalDigits is 2, then actual value is 0.01. - The value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647). - This parameter does not apply to sensors without numerical reading." - ::= { unitSensorConfigurationEntry 31 } + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The upper warning threshold as a signed integer. + The value of this OID variable should be scaled by + unitSensorDecimalDigits. For example, if the value is 1 and + unitSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { unitSensorConfigurationEntry 31 } +-- inletConfigurationTable: inlet information and settings +inletConfigurationTable OBJECT-TYPE + SYNTAX SEQUENCE OF InletConfigurationEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of inlet configuration entries. The number of + entries is given by the value of inletCount for the PDU." + ::= { inlets 3 } --- the inletConfiguration table +inletConfigurationEntry OBJECT-TYPE + SYNTAX InletConfigurationEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing parametersfor a particular inlet." + INDEX { pduId, inletId } + ::= { inletConfigurationTable 1 } --- The inletConfiguration table contains information on the PDU's inlets. +InletConfigurationEntryStruct ::= SEQUENCE { + inletId Integer32, + inletLabel DisplayString, + inletName DisplayString, + inletPlug PlugTypeEnumeration, + inletPoleCount Integer32, + inletRatedVoltage DisplayString, + inletRatedCurrent DisplayString, + inletRatedFrequency DisplayString, + inletRatedVA DisplayString, + inletDeviceCapabilities BITS, + inletPoleCapabilities BITS, + inletPlugDescriptor DisplayString, + inletEnableState TruthValue, + inletRCMResidualOperatingCurrent Unsigned32 + } +inletId OBJECT-TYPE + SYNTAX Integer32(1..256) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A unique value for each inlet. Its value ranges between 1 and the + value of inletCount." + ::= { inletConfigurationEntry 1 } -inletConfigurationTable OBJECT-TYPE - SYNTAX SEQUENCE OF InletConfigurationEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A list of inlet configuration entries. The number of - entries is given by the value of inletCount for the PDU." - ::= { inlets 3 } +inletLabel OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The label on the PDU identifying the inlet." + ::= { inletConfigurationEntry 2 } -inletConfigurationEntry OBJECT-TYPE - SYNTAX InletConfigurationEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "An entry containing parametersfor a particular inlet." - INDEX { pduId, inletId } - ::= { inletConfigurationTable 1 } +inletName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The user-defined name." + ::= { inletConfigurationEntry 3 } -InletConfigurationEntryStruct ::= SEQUENCE {inletId Integer32, - inletLabel DisplayString, - inletName DisplayString, - inletPlug PlugTypeEnumeration, - inletPoleCount Integer32, - inletRatedVoltage DisplayString, - inletRatedCurrent DisplayString, - inletRatedFrequency DisplayString, - inletRatedVA DisplayString, - inletDeviceCapabilities BITS, - inletPoleCapabilities BITS, - inletPlugDescriptor DisplayString, - inletEnableState TruthValue, - inletRCMResidualOperatingCurrent Unsigned32 - } +inletPlug OBJECT-TYPE + SYNTAX PlugTypeEnumeration + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The type of plug/receptacle wired to the inlet. + Note: PlugTypeEnumeration is no longer updated, unlisted plugs will be + reported as plugOTHER. Use inletPlugDescriptor to reliably determine + the plug type." + ::= { inletConfigurationEntry 4 } -inletId OBJECT-TYPE - SYNTAX Integer32(1..256) - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A unique value for each inlet. Its value - ranges between 1 and the value of inletCount." - ::= { inletConfigurationEntry 1 } +inletPoleCount OBJECT-TYPE + SYNTAX Integer32(2..5) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of poles. + PDU: + 2 for 1-phase circuits + 3 for 3-phase delta-wired models + 4 for 3-phase wye-wired models, pole 4 is neutral + Power Meter: + 2 to 5 depending on the power meter type: + Pole 1 is Phase A + Pole 2 is Phase B + Pole 3 is Phase C + Pole 4 is Neutral + Pole 5 is Earth" + ::= { inletConfigurationEntry 5 } +inletRatedVoltage OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The inlet voltage rating." + ::= { inletConfigurationEntry 6 } -inletLabel OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The label on the PDU identifying the inlet." - ::= { inletConfigurationEntry 2 } +inletRatedCurrent OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The inlet current rating." + ::= { inletConfigurationEntry 7 } -inletName OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The user-defined name." - ::= { inletConfigurationEntry 3 } +inletRatedFrequency OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The inlet frequency rating. + Deprecated: use pduRatedFrequency for unit nameplate information." + ::= { inletConfigurationEntry 8 } -inletPlug OBJECT-TYPE - SYNTAX PlugTypeEnumeration - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The type of plug/receptacle wired to the inlet." - ::= { inletConfigurationEntry 4 } +inletRatedVA OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The inlet VA (VoltAmps) rating. + Deprecated: use pduRatedVA for unit nameplate information." + ::= { inletConfigurationEntry 9 } -inletPoleCount OBJECT-TYPE - SYNTAX Integer32(2..4) - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The number of poles. For inlets with neutral poles, this number will - include the neutral pole; however, sensors are not supported for - neutral poles" - ::= { inletConfigurationEntry 5 } +inletDeviceCapabilities OBJECT-TYPE + SYNTAX BITS { rmsCurrent(0), + peakCurrent(1), + unbalancedCurrent(2), + rmsVoltage(3), + activePower(4), + apparentPower(5), + powerFactor(6), + activeEnergy(7), + apparentEnergy(8), + surgeProtectorStatus(21), + frequency(22), + phaseAngle(23), + residualCurrent(25), + rcmState(26), + reactivePower(28), + powerQuality(31) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A bit string indicating which inlet sensors are available." + ::= { inletConfigurationEntry 10 } -inletRatedVoltage OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The inlet voltage rating." - ::= { inletConfigurationEntry 6 } +inletPoleCapabilities OBJECT-TYPE + SYNTAX BITS { rmsCurrent(0), + peakCurrent(1), + rmsVoltage(3), + activePower(4), + apparentPower(5), + powerFactor(6), + activeEnergy(7), + apparentEnergy(8), + phaseAngle(23), + rmsVoltageLN(24), + reactivePower(28), + displacementPowerFactor(34) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A bit string indicating which inlet pole sensors are available." + ::= { inletConfigurationEntry 11 } +inletPlugDescriptor OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The inlet plug type as a string." + ::= { inletConfigurationEntry 12 } -inletRatedCurrent OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The inlet current rating." - ::= { inletConfigurationEntry 7 } +inletEnableState OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enable/disable PDU operation for this inlet. + When PDU operation is disabled the sensors for this inlet and all + children will no longer be updated, and outlet switching is no longer + allowed. This is only meaningful for multi-inlet units if one inlet + is temporarily expected to be powered down. + Disabling the inlet of a single-inlet unit is forbidden and any + attempt to do so will result in an error." + ::= { inletConfigurationEntry 13 } +inletRCMResidualOperatingCurrent OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS obsolete + DESCRIPTION + "**NOTE:This object is obsolete. + Its functionality was implemented by existing RCM sensor thresholds. + The Residual Operating Current (Threshold) for the RCM State sensor. + For inlets without an RCM, any attempt to access this OID will return + NoSuchInstance error. The value of this OID is in milliamps." + ::= { inletConfigurationEntry 14 } -inletRatedFrequency OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The inlet frequency rating." - ::= { inletConfigurationEntry 8 } +-- inletPoleConfigurationTable: inlet pole information +inletPoleConfigurationTable OBJECT-TYPE + SYNTAX SEQUENCE OF InletPoleConfigurationEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of inlet pole configuration entries. The number of + entries is given by the value of inletPoleCount for the inlet." + ::= { inlets 5 } +inletPoleConfigurationEntry OBJECT-TYPE + SYNTAX InletPoleConfigurationEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing parameters for a particular inlet pole." + INDEX { pduId, inletId, inletPoleIndex } + ::= { inletPoleConfigurationTable 1 } +InletPoleConfigurationEntryStruct ::= SEQUENCE { + inletPoleLine LineEnumeration, + inletPoleNode Integer32 + } -inletRatedVA OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The inlet VA (VoltAmps) rating." - ::= { inletConfigurationEntry 9 } +inletPoleLine OBJECT-TYPE + SYNTAX LineEnumeration + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The phase for this inlet pole." + ::= { inletPoleConfigurationEntry 1 } +inletPoleNode OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The node to which this inlet pole is connected" + ::= { inletPoleConfigurationEntry 2 } +-- inletSensorConfigurationTable: information and settings for inlet sensors -inletDeviceCapabilities OBJECT-TYPE - SYNTAX BITS{ - rmsCurrent(0), - peakCurrent(1), - unbalancedCurrent(2), - rmsVoltage(3), - activePower(4), - apparentPower(5), - powerFactor(6), - activeEnergy(7), - apparentEnergy(8), - surgeProtectorStatus(21), - frequency(22), - phaseAngle(23), - residualCurrent(26), - rcmState(27), - powerQuality(31) - } - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "A bit string which indicates which inlet sensors are available." - ::= { inletConfigurationEntry 10 } +inletSensorConfigurationTable OBJECT-TYPE + SYNTAX SEQUENCE OF InletSensorConfigurationEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of configuration entries for an inlet sensor." + ::= { inlets 4 } -inletPoleCapabilities OBJECT-TYPE - SYNTAX BITS{ - rmsCurrent(0), - peakCurrent(1), - rmsVoltage(3), - activePower(4), - apparentPower(5), - powerFactor(6), - activeEnergy(7), - apparentEnergy(8), - rmsVoltageLN(24) - } - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "A bit string which indicates which inletpole sensors are available." - ::= { inletConfigurationEntry 11 } - -inletPlugDescriptor OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "Description of the Plug" - ::= { inletConfigurationEntry 12 } - -inletEnableState OBJECT-TYPE - SYNTAX TruthValue - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "Is this PDU operation is enabled for this inlet? - When PDU operation is disabled the sensors for this inlet and all - children will no longer be updated, and outlet switching is no longer - allowed. This is only meaningful for multi-inlet units if one inlet - is temporarily expected to be powered down. - Disabling the inlet of a single-inlet unit is forbidden and any - attempt to do so will result in an error." - ::= { inletConfigurationEntry 13 } - - -inletRCMResidualOperatingCurrent OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The Residual Operating Current (Threshold) for the RCM State sensor. - For inlets without an RCM, any attempt to access this OID will return - NoSuchInstance error. The value of this OID is in milliamps. - " - ::= { inletConfigurationEntry 14 } - - - - - - - --- The inletSensorConfiguration table contains information on the PDU's inlet Sensors. - - -inletSensorConfigurationTable OBJECT-TYPE - SYNTAX SEQUENCE OF InletSensorConfigurationEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A list of configuration entries for an inlet sensor." - ::= { inlets 4 } - -inletSensorConfigurationEntry OBJECT-TYPE - SYNTAX InletSensorConfigurationEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "An entry containing objects for configuring an inlet sensor." - INDEX { pduId, inletId, sensorType } - ::= { inletSensorConfigurationTable 1 } +inletSensorConfigurationEntry OBJECT-TYPE + SYNTAX InletSensorConfigurationEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing objects for configuring an inlet sensor." + INDEX { pduId, inletId, sensorType } + ::= { inletSensorConfigurationTable 1 } InletSensorConfigurationEntryStruct ::= SEQUENCE { - inletSensorLogAvailable TruthValue, - inletSensorUnits SensorUnitsEnumeration, - inletSensorDecimalDigits Unsigned32, - inletSensorAccuracy HundredthsOfAPercentage, - inletSensorResolution Unsigned32, - inletSensorTolerance Unsigned32, - inletSensorMaximum Unsigned32, - inletSensorMinimum Unsigned32, - inletSensorHysteresis Unsigned32, - inletSensorStateChangeDelay Unsigned32, - inletSensorLowerCriticalThreshold Unsigned32, - inletSensorLowerWarningThreshold Unsigned32, - inletSensorUpperCriticalThreshold Unsigned32, - inletSensorUpperWarningThreshold Unsigned32, - inletSensorEnabledThresholds BITS, - inletSensorSignedMaximum Integer32, - inletSensorSignedMinimum Integer32, - inletSensorSignedLowerCriticalThreshold Integer32, - inletSensorSignedLowerWarningThreshold Integer32, - inletSensorSignedUpperCriticalThreshold Integer32, - inletSensorSignedUpperWarningThreshold Integer32 - } + inletSensorLogAvailable TruthValue, + inletSensorUnits SensorUnitsEnumeration, + inletSensorDecimalDigits Unsigned32, + inletSensorAccuracy HundredthsOfAPercentage, + inletSensorResolution Unsigned32, + inletSensorTolerance Unsigned32, + inletSensorMaximum Unsigned32, + inletSensorMinimum Unsigned32, + inletSensorHysteresis Unsigned32, + inletSensorStateChangeDelay Unsigned32, + inletSensorLowerCriticalThreshold Unsigned32, + inletSensorLowerWarningThreshold Unsigned32, + inletSensorUpperCriticalThreshold Unsigned32, + inletSensorUpperWarningThreshold Unsigned32, + inletSensorEnabledThresholds BITS, + inletSensorSignedMaximum Integer32, + inletSensorSignedMinimum Integer32, + inletSensorSignedLowerCriticalThreshold Integer32, + inletSensorSignedLowerWarningThreshold Integer32, + inletSensorSignedUpperCriticalThreshold Integer32, + inletSensorSignedUpperWarningThreshold Integer32 + } -inletSensorLogAvailable OBJECT-TYPE - SYNTAX TruthValue - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "Is logging enabled for the sensor?" - ::= { inletSensorConfigurationEntry 4 } +inletSensorLogAvailable OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is data logging enabled for the sensor?" + ::= { inletSensorConfigurationEntry 4 } -inletSensorUnits OBJECT-TYPE - SYNTAX SensorUnitsEnumeration - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The base units. - This parameter does not apply to sensors without numerical reading, - e.g. surge protector status sensors." - ::= { inletSensorConfigurationEntry 6 } +inletSensorUnits OBJECT-TYPE + SYNTAX SensorUnitsEnumeration + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The unit in which the sensor reading is reported. + This parameter does not apply to sensors without numerical reading." + ::= { inletSensorConfigurationEntry 6 } -inletSensorDecimalDigits OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The number of digits displayed to the right of the decimal point. - This parameter does not apply to sensors without numerical reading, - e.g. surge protector status sensors." - ::= { inletSensorConfigurationEntry 7 } +inletSensorDecimalDigits OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of digits displayed to the right of the decimal point. + This parameter does not apply to sensors without numerical reading." + ::= { inletSensorConfigurationEntry 7 } -inletSensorAccuracy OBJECT-TYPE - SYNTAX HundredthsOfAPercentage - MAX-ACCESS read-only - STATUS deprecated - DESCRIPTION - "The accuracy: how close (in percent) the measurement is to the actual value. - This parameter does not apply to sensors without numerical reading, - e.g. surge protector status sensors." - ::= { inletSensorConfigurationEntry 8 } +inletSensorAccuracy OBJECT-TYPE + SYNTAX HundredthsOfAPercentage + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The accuracy: the maximum relative difference (in percent) between + measurement and the actual value. + This parameter does not apply to sensors without numerical reading." + ::= { inletSensorConfigurationEntry 8 } -inletSensorResolution OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The resolution: the minimum difference between any two measured values - The value of this OID variable should be scaled by - inletSensorDecimalDigits. For example, if the value is 1 and - inletSensorDecimalDigits is 2, then actual value is 0.01. - This parameter does not apply to sensors without numerical reading, - e.g. surge protector status sensors." - ::= { inletSensorConfigurationEntry 9 } +inletSensorResolution OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The resolution: the minimum difference between any two measured values + The value of this OID variable should be scaled by + inletSensorDecimalDigits. For example, if the value is 1 and + inletSensorDecimalDigits is 2, then actual value is 0.01. + This parameter does not apply to sensors without numerical reading." + ::= { inletSensorConfigurationEntry 9 } -inletSensorTolerance OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS deprecated - DESCRIPTION - "The resolution: the difference between a sensor value and the actual value - The value of this OID variable should be scaled by - (inletSensorDecimalDigits + 1). For example, if the value is 50 and - inletSensorDecimalDigits is 2, then actual value is 0.05. - This parameter does not apply to sensors without numerical reading, - e.g. surge protector status sensors." - ::= { inletSensorConfigurationEntry 10 } +inletSensorTolerance OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The tolerance: the maximum difference between measurement and the + actual value. The value of this OID variable should be scaled by + (inletSensorDecimalDigits + 1). For example, if the value is 50 and + inletSensorDecimalDigits is 2, then actual value is 0.05. + This parameter does not apply to sensors without numerical reading." + ::= { inletSensorConfigurationEntry 10 } -inletSensorMaximum OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The largest possible reading as an unsigned integer. - The value of this OID variable should be scaled by - inletSensorDecimalDigits. For example, if the value is 1 and - inletSensorDecimalDigits is 2, then actual value is 0.01. - The value is clamped if the scaled maximum exceeds 4294967295. It - is undefined for sensors which can have negative readings. - This parameter does not apply to sensors without numerical reading, - e.g. surge protector status sensors." - ::= { inletSensorConfigurationEntry 11 } +inletSensorMaximum OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The largest possible reading as an unsigned integer. + The value of this OID variable should be scaled by + inletSensorDecimalDigits. For example, if the value is 1 and + inletSensorDecimalDigits is 2, then actual value is 0.01. + The value is clamped if the scaled maximum exceeds 4294967295. It + is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { inletSensorConfigurationEntry 11 } -inletSensorMinimum OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The smallest possible reading as an unsigned integer. - The value of this OID variable should be scaled by - inletSensorDecimalDigits. For example, if the value is 1 and - inletSensorDecimalDigits is 2, then actual value is 0.01. - The value is undefined for sensors which can have negative readings. - This parameter does not apply to sensors without numerical reading, - e.g. surge protector status sensors." - ::= { inletSensorConfigurationEntry 12 } +inletSensorMinimum OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The smallest possible reading as an unsigned integer. + The value of this OID variable should be scaled by + inletSensorDecimalDigits. For example, if the value is 1 and + inletSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { inletSensorConfigurationEntry 12 } -inletSensorHysteresis OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The hysteresis used for deassertions - The value of this OID variable should be scaled by - inletSensorDecimalDigits. For example, if the value is 1 and - inletSensorDecimalDigits is 2, then actual value is 0.01. - This parameter does not apply to sensors without numerical reading, - e.g. surge protector status sensors." - ::= { inletSensorConfigurationEntry 13 } +inletSensorHysteresis OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The hysteresis used when crossing a threshold towards the normal state. + The value of this OID variable should be scaled by + inletSensorDecimalDigits. For example, if the value is 1 and + inletSensorDecimalDigits is 2, then actual value is 0.01. + This parameter does not apply to sensors without numerical reading." + ::= { inletSensorConfigurationEntry 13 } -inletSensorStateChangeDelay OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The delay measured in samples before a state is asserted. - If the value is zero, then the state is asserted as soon as - it is detected; if it is non-zero, say n, then the assertion - condition must exist for n+1 consecutive samples before the corresponding - assertion event is reported. - This parameter does not apply to sensors without numerical reading, - e.g. surge protector status sensors." - ::= { inletSensorConfigurationEntry 14 } +inletSensorStateChangeDelay OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The delay measured in samples before a state is asserted. + If the value is zero, then the state is asserted as soon as + it is detected; if it is non-zero, say n, then the assertion + condition must exist for n+1 consecutive samples before the + event is reported. + This parameter does not apply to sensors without numerical reading." + ::= { inletSensorConfigurationEntry 14 } -inletSensorLowerCriticalThreshold OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The lower critical threshold as an unsigned integer. - The value of this OID variable should be scaled by - inletSensorDecimalDigits. For example, if the value is 1 and - inletSensorDecimalDigits is 2, then actual value is 0.01. - The value is clamped if the scaled threshold exceeds 4294967295. It - is undefined for sensors which can have negative readings. - This parameter does not apply to sensors without numerical reading, - e.g. surge protector status sensors." - ::= { inletSensorConfigurationEntry 21 } +inletSensorLowerCriticalThreshold OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The lower critical threshold as an unsigned integer. + The value of this OID variable should be scaled by + inletSensorDecimalDigits. For example, if the value is 1 and + inletSensorDecimalDigits is 2, then actual value is 0.01. + The value is clamped if the scaled threshold exceeds 4294967295. It + is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { inletSensorConfigurationEntry 21 } -inletSensorLowerWarningThreshold OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The lower warning threshold as an unsigned integer. - The value of this OID variable should be scaled by - inletSensorDecimalDigits. For example, if the value is 1 and - inletSensorDecimalDigits is 2, then actual value is 0.01. - The value is clamped if the scaled threshold exceeds 4294967295. It - is undefined for sensors which can have negative readings. - This parameter does not apply to sensors without numerical reading, - e.g. surge protector status sensors." - ::= { inletSensorConfigurationEntry 22 } +inletSensorLowerWarningThreshold OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The lower warning threshold as an unsigned integer. + The value of this OID variable should be scaled by + inletSensorDecimalDigits. For example, if the value is 1 and + inletSensorDecimalDigits is 2, then actual value is 0.01. + The value is clamped if the scaled threshold exceeds 4294967295. It + is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { inletSensorConfigurationEntry 22 } -inletSensorUpperCriticalThreshold OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The upper critical threshold as an unsigned integer. - The value of this OID variable should be scaled by - inletSensorDecimalDigits. For example, if the value is 1 and - inletSensorDecimalDigits is 2, then actual value is 0.01. - The value is clamped if the scaled threshold exceeds 4294967295. It - is undefined for sensors which can have negative readings. - This parameter does not apply to sensors without numerical reading, - e.g. surge protector status sensors." - ::= { inletSensorConfigurationEntry 23 } +inletSensorUpperCriticalThreshold OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The upper critical threshold as an unsigned integer. + The value of this OID variable should be scaled by + inletSensorDecimalDigits. For example, if the value is 1 and + inletSensorDecimalDigits is 2, then actual value is 0.01. + The value is clamped if the scaled threshold exceeds 4294967295. It + is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { inletSensorConfigurationEntry 23 } -inletSensorUpperWarningThreshold OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The upper warning threshold as an unsigned integer. - The value of this OID variable should be scaled by - inletSensorDecimalDigits. For example, if the value is 1 and - inletSensorDecimalDigits is 2, then actual value is 0.01. - The value is clamped if the scaled threshold exceeds 4294967295. It - is undefined for sensors which can have negative readings. - This parameter does not apply to sensors without numerical reading, - e.g. surge protector status sensors." - ::= { inletSensorConfigurationEntry 24 } +inletSensorUpperWarningThreshold OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The upper warning threshold as an unsigned integer. + The value of this OID variable should be scaled by + inletSensorDecimalDigits. For example, if the value is 1 and + inletSensorDecimalDigits is 2, then actual value is 0.01. + The value is clamped if the scaled threshold exceeds 4294967295. It + is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { inletSensorConfigurationEntry 24 } -inletSensorEnabledThresholds OBJECT-TYPE - SYNTAX BITS{ - lowerCritical(0), - lowerWarning(1), - upperWarning(2), - upperCritical(3) - } - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "A bit string which indicates which thresholds are enabled. - This parameter does not apply to sensors without numerical reading, - e.g. surge protector status sensors." - ::= { inletSensorConfigurationEntry 25 } +inletSensorEnabledThresholds OBJECT-TYPE + SYNTAX BITS { lowerCritical(0), + lowerWarning(1), + upperWarning(2), + upperCritical(3) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "A bit string indicating which thresholds are enabled. + This parameter does not apply to sensors without numerical reading." + ::= { inletSensorConfigurationEntry 25 } -inletSensorSignedMaximum OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The largest possible reading as a signed integer. - The value of this OID variable should be scaled by - inletSensorDecimalDigits. For example, if the value is 1 and - inletSensorDecimalDigits is 2, then actual value is 0.01. - The value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647). - This parameter does not apply to sensors without numerical reading, - e.g. surge protector status sensors." - ::= { inletSensorConfigurationEntry 26 } +inletSensorSignedMaximum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The largest possible reading as a signed integer. + The value of this OID variable should be scaled by + inletSensorDecimalDigits. For example, if the value is 1 and + inletSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { inletSensorConfigurationEntry 26 } -inletSensorSignedMinimum OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The smallest possible reading as a signed integer. - The value of this OID variable should be scaled by - inletSensorDecimalDigits. For example, if the value is 1 and - inletSensorDecimalDigits is 2, then actual value is 0.01. - This value determines whether to use the signed or unsigned threshold - and value columns: If the minimum is below zero the sensor can have - negative readings and the signed columns should be used. - This parameter does not apply to sensors without numerical reading, - e.g. surge protector status sensors." - ::= { inletSensorConfigurationEntry 27 } +inletSensorSignedMinimum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The smallest possible reading as a signed integer. + The value of this OID variable should be scaled by + inletSensorDecimalDigits. For example, if the value is 1 and + inletSensorDecimalDigits is 2, then actual value is 0.01. + This value determines whether to use the signed or unsigned threshold + and value columns: If the minimum is below zero the sensor can have + negative readings and the signed columns should be used. + This parameter does not apply to sensors without numerical reading." + ::= { inletSensorConfigurationEntry 27 } inletSensorSignedLowerCriticalThreshold OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The lower critical threshold as a signed integer. - The value of this OID variable should be scaled by - inletSensorDecimalDigits. For example, if the value is 1 and - inletSensorDecimalDigits is 2, then actual value is 0.01. - The value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647). - This parameter does not apply to sensors without numerical reading, - e.g. surge protector status sensors." - ::= { inletSensorConfigurationEntry 28 } + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The lower critical threshold as a signed integer. + The value of this OID variable should be scaled by + inletSensorDecimalDigits. For example, if the value is 1 and + inletSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { inletSensorConfigurationEntry 28 } inletSensorSignedLowerWarningThreshold OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The lower warning threshold as a signed integer. - The value of this OID variable should be scaled by - inletSensorDecimalDigits. For example, if the value is 1 and - inletSensorDecimalDigits is 2, then actual value is 0.01. - The value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647). - This parameter does not apply to sensors without numerical reading, - e.g. surge protector status sensors." - ::= { inletSensorConfigurationEntry 29 } + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The lower warning threshold as a signed integer. + The value of this OID variable should be scaled by + inletSensorDecimalDigits. For example, if the value is 1 and + inletSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { inletSensorConfigurationEntry 29 } inletSensorSignedUpperCriticalThreshold OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The upper critical threshold as a signed integer. - The value of this OID variable should be scaled by - inletSensorDecimalDigits. For example, if the value is 1 and - inletSensorDecimalDigits is 2, then actual value is 0.01. - The value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647). - This parameter does not apply to sensors without numerical reading, - e.g. surge protector status sensors." - ::= { inletSensorConfigurationEntry 30 } + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The upper critical threshold as a signed integer. + The value of this OID variable should be scaled by + inletSensorDecimalDigits. For example, if the value is 1 and + inletSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { inletSensorConfigurationEntry 30 } inletSensorSignedUpperWarningThreshold OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The upper warning threshold as a signed integer. - The value of this OID variable should be scaled by - inletSensorDecimalDigits. For example, if the value is 1 and - inletSensorDecimalDigits is 2, then actual value is 0.01. - The value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647). - This parameter does not apply to sensors without numerical reading, - e.g. surge protector status sensors." - ::= { inletSensorConfigurationEntry 31 } + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The upper warning threshold as a signed integer. + The value of this OID variable should be scaled by + inletSensorDecimalDigits. For example, if the value is 1 and + inletSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { inletSensorConfigurationEntry 31 } +-- inletPoleSensorConfigurationTable: information and settings for inlet pole sensors +inletPoleSensorConfigurationTable OBJECT-TYPE + SYNTAX SEQUENCE OF InletPoleSensorConfigurationEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of configuration entries for an inlet pole sensor." + ::= { inlets 6 } --- The inletPoleSensorConfiguration table contains information on the PDU's inlet pole Sensors. +inletPoleSensorConfigurationEntry OBJECT-TYPE + SYNTAX InletPoleSensorConfigurationEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing objects for configuring an inlet pole sensor." + INDEX { pduId, inletId, inletPoleIndex, sensorType } + ::= { inletPoleSensorConfigurationTable 1 } +InletPoleSensorConfigurationEntryStruct ::= SEQUENCE { + inletPoleIndex Integer32, + inletPoleSensorLogAvailable TruthValue, + inletPoleSensorUnits SensorUnitsEnumeration, + inletPoleSensorDecimalDigits Unsigned32, + inletPoleSensorAccuracy HundredthsOfAPercentage, + inletPoleSensorResolution Unsigned32, + inletPoleSensorTolerance Unsigned32, + inletPoleSensorMaximum Unsigned32, + inletPoleSensorMinimum Unsigned32, + inletPoleSensorHysteresis Unsigned32, + inletPoleSensorStateChangeDelay Unsigned32, + inletPoleSensorLowerCriticalThreshold Unsigned32, + inletPoleSensorLowerWarningThreshold Unsigned32, + inletPoleSensorUpperCriticalThreshold Unsigned32, + inletPoleSensorUpperWarningThreshold Unsigned32, + inletPoleSensorEnabledThresholds BITS, + inletPoleSensorSignedMaximum Integer32, + inletPoleSensorSignedMinimum Integer32, + inletPoleSensorSignedLowerCriticalThreshold Integer32, + inletPoleSensorSignedLowerWarningThreshold Integer32, + inletPoleSensorSignedUpperCriticalThreshold Integer32, + inletPoleSensorSignedUpperWarningThreshold Integer32 + } -inletPoleSensorConfigurationTable OBJECT-TYPE - SYNTAX SEQUENCE OF InletPoleSensorConfigurationEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A list of configuration entries for an inlet pole sensor." - ::= { inlets 6 } +inletPoleIndex OBJECT-TYPE + SYNTAX Integer32(1..256) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A unique value for each inlet pole. Its value + ranges between 1 and the value of inletPoleCount." + ::= { inletPoleSensorConfigurationEntry 1 } -inletPoleSensorConfigurationEntry OBJECT-TYPE - SYNTAX InletPoleSensorConfigurationEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "An entry containing objects - for configuring an inlet pole sensor." - INDEX { pduId, inletId,inletPoleIndex,sensorType } - ::= { inletPoleSensorConfigurationTable 1 } +inletPoleSensorLogAvailable OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is data logging enabled for the sensor?" + ::= { inletPoleSensorConfigurationEntry 4 } -InletPoleSensorConfigurationEntryStruct ::= SEQUENCE { inletPoleIndex Integer32, - inletPoleSensorLogAvailable TruthValue, - inletPoleSensorUnits SensorUnitsEnumeration, - inletPoleSensorDecimalDigits Unsigned32, - inletPoleSensorAccuracy HundredthsOfAPercentage, - inletPoleSensorResolution Unsigned32, - inletPoleSensorTolerance Unsigned32, - inletPoleSensorMaximum Unsigned32, - inletPoleSensorMinimum Unsigned32, - inletPoleSensorHysteresis Unsigned32, - inletPoleSensorStateChangeDelay Unsigned32, - inletPoleSensorLowerCriticalThreshold Unsigned32, - inletPoleSensorLowerWarningThreshold Unsigned32, - inletPoleSensorUpperCriticalThreshold Unsigned32, - inletPoleSensorUpperWarningThreshold Unsigned32, - inletPoleSensorEnabledThresholds BITS, - inletPoleSensorSignedMaximum Integer32, - inletPoleSensorSignedMinimum Integer32, - inletPoleSensorSignedLowerCriticalThreshold Integer32, - inletPoleSensorSignedLowerWarningThreshold Integer32, - inletPoleSensorSignedUpperCriticalThreshold Integer32, - inletPoleSensorSignedUpperWarningThreshold Integer32 - } +inletPoleSensorUnits OBJECT-TYPE + SYNTAX SensorUnitsEnumeration + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The unit in which the sensor reading is reported. + This parameter does not apply to sensors without numerical reading." + ::= { inletPoleSensorConfigurationEntry 6 } -inletPoleIndex OBJECT-TYPE - SYNTAX Integer32(1..256) - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A unique value for each inlet Pole. Its value - ranges between 1 and the value of inletPoleCount." - ::= { inletPoleSensorConfigurationEntry 1 } +inletPoleSensorDecimalDigits OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of digits displayed to the right of the decimal point. + This parameter does not apply to sensors without numerical reading." + ::= { inletPoleSensorConfigurationEntry 7 } -inletPoleSensorLogAvailable OBJECT-TYPE - SYNTAX TruthValue - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "Is logging enabled for the sensor?" - ::= { inletPoleSensorConfigurationEntry 4 } +inletPoleSensorAccuracy OBJECT-TYPE + SYNTAX HundredthsOfAPercentage + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The accuracy: the maximum relative difference (in percent) between + measurement and the actual value. + This parameter does not apply to sensors without numerical reading." + ::= { inletPoleSensorConfigurationEntry 8 } +inletPoleSensorResolution OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The resolution: the minimum difference between any two measured values + The value of this OID variable should be scaled by + inletPoleSensorDecimalDigits. For example, if the value is 1 and + inletPoleSensorDecimalDigits is 2, then actual value is 0.01. + This parameter does not apply to sensors without numerical reading." + ::= { inletPoleSensorConfigurationEntry 9 } -inletPoleSensorUnits OBJECT-TYPE - SYNTAX SensorUnitsEnumeration - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The base units. - This parameter does not apply to sensors without numerical reading." - ::= { inletPoleSensorConfigurationEntry 6 } +inletPoleSensorTolerance OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The tolerance: the maximum difference between measurement and the + actual value. The value of this OID variable should be scaled by + (inletPoleSensorDecimalDigits + 1). For example, if the value is 50 and + inletPoleSensorDecimalDigits is 2, then actual value is 0.05. + This parameter does not apply to sensors without numerical reading." + ::= { inletPoleSensorConfigurationEntry 10 } +inletPoleSensorMaximum OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The largest possible reading as an unsigned integer. + The value of this OID variable should be scaled by + inletPoleSensorDecimalDigits. For example, if the value is 1 and + inletPoleSensorDecimalDigits is 2, then actual value is 0.01. + The value is clamped if the scaled maximum exceeds 4294967295. It + is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { inletPoleSensorConfigurationEntry 11 } -inletPoleSensorDecimalDigits OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The number of digits displayed to the right of the decimal point. - This parameter does not apply to sensors without numerical reading." - ::= { inletPoleSensorConfigurationEntry 7 } +inletPoleSensorMinimum OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The smallest possible reading as an unsigned integer. + The value of this OID variable should be scaled by + inletPoleSensorDecimalDigits. For example, if the value is 1 and + inletPoleSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { inletPoleSensorConfigurationEntry 12 } +inletPoleSensorHysteresis OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The hysteresis used when crossing a threshold towards the normal state. + The value of this OID variable should be scaled by + inletPoleSensorDecimalDigits. For example, if the value is 1 and + inletPoleSensorDecimalDigits is 2, then actual value is 0.01. + This parameter does not apply to sensors without numerical reading." + ::= { inletPoleSensorConfigurationEntry 13 } - - -inletPoleSensorAccuracy OBJECT-TYPE - SYNTAX HundredthsOfAPercentage - MAX-ACCESS read-only - STATUS deprecated - DESCRIPTION - "The accuracy: how close (in percent) the measurement is to the actual value. - This parameter does not apply to sensors without numerical reading." - ::= { inletPoleSensorConfigurationEntry 8 } - - -inletPoleSensorResolution OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The resolution: the minimum difference between any two measured values - The value of this OID variable should be scaled by - inletPoleSensorDecimalDigits. For example, if the value is 1 and - inletPoleSensorDecimalDigits is 2, then actual value is 0.01. - This parameter does not apply to sensors without numerical reading." - ::= { inletPoleSensorConfigurationEntry 9 } - -inletPoleSensorTolerance OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS deprecated - DESCRIPTION - "The resolution: the difference between a sensor value and the actual value - The value of this OID variable should be scaled by - (inletPoleSensorDecimalDigits + 1). For example, if the value is 50 and - inletPoleSensorDecimalDigits is 2, then actual value is 0.05. - This parameter does not apply to sensors without numerical reading." - ::= { inletPoleSensorConfigurationEntry 10 } - -inletPoleSensorMaximum OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The largest possible reading as an unsigned integer. - The value of this OID variable should be scaled by - inletPoleSensorDecimalDigits. For example, if the value is 1 and - inletPoleSensorDecimalDigits is 2, then actual value is 0.01. - The value is clamped if the scaled maximum exceeds 4294967295. It - is undefined for sensors which can have negative readings. - This parameter does not apply to sensors without numerical reading." - ::= { inletPoleSensorConfigurationEntry 11 } - -inletPoleSensorMinimum OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The smallest possible reading as an unsigned integer. - The value of this OID variable should be scaled by - inletPoleSensorDecimalDigits. For example, if the value is 1 and - inletPoleSensorDecimalDigits is 2, then actual value is 0.01. - The value is undefined for sensors which can have negative readings. - This parameter does not apply to sensors without numerical reading." - ::= { inletPoleSensorConfigurationEntry 12 } - -inletPoleSensorHysteresis OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The hysteresis used for deassertions - The value of this OID variable should be scaled by - inletPoleSensorDecimalDigits. For example, if the value is 1 and - inletPoleSensorDecimalDigits is 2, then actual value is 0.01. - This parameter does not apply to sensors without numerical reading." - ::= { inletPoleSensorConfigurationEntry 13 } - -inletPoleSensorStateChangeDelay OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The delay measured in samples before a state is asserted. - If the value is zero, then the state is asserted as soon as - it is detected; if it is non-zero, say n, then the assertion - condition must exist for n+1 consecutive samples before the corresponding - assertion event is reported. - This parameter does not apply to sensors without numerical reading." - ::= { inletPoleSensorConfigurationEntry 14 } +inletPoleSensorStateChangeDelay OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The delay measured in samples before a state is asserted. + If the value is zero, then the state is asserted as soon as + it is detected; if it is non-zero, say n, then the assertion + condition must exist for n+1 consecutive samples before the + event is reported. + This parameter does not apply to sensors without numerical reading." + ::= { inletPoleSensorConfigurationEntry 14 } inletPoleSensorLowerCriticalThreshold OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The lower critical threshold as an unsigned integer. - The value of this OID variable should be scaled by - inletPoleSensorDecimalDigits. For example, if the value is 1 and - inletPoleSensorDecimalDigits is 2, then actual value is 0.01. - The value is clamped if the scaled threshold exceeds 4294967295. It - is undefined for sensors which can have negative readings. - This parameter does not apply to sensors without numerical reading." - ::= { inletPoleSensorConfigurationEntry 21 } + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The lower critical threshold as an unsigned integer. + The value of this OID variable should be scaled by + inletPoleSensorDecimalDigits. For example, if the value is 1 and + inletPoleSensorDecimalDigits is 2, then actual value is 0.01. + The value is clamped if the scaled threshold exceeds 4294967295. It + is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { inletPoleSensorConfigurationEntry 21 } -inletPoleSensorLowerWarningThreshold OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The lower warning threshold as an unsigned integer. - The value of this OID variable should be scaled by - inletPoleSensorDecimalDigits. For example, if the value is 1 and - inletPoleSensorDecimalDigits is 2, then actual value is 0.01. - The value is clamped if the scaled threshold exceeds 4294967295. It - is undefined for sensors which can have negative readings. - This parameter does not apply to sensors without numerical reading." - ::= { inletPoleSensorConfigurationEntry 22 } +inletPoleSensorLowerWarningThreshold OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The lower warning threshold as an unsigned integer. + The value of this OID variable should be scaled by + inletPoleSensorDecimalDigits. For example, if the value is 1 and + inletPoleSensorDecimalDigits is 2, then actual value is 0.01. + The value is clamped if the scaled threshold exceeds 4294967295. It + is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { inletPoleSensorConfigurationEntry 22 } inletPoleSensorUpperCriticalThreshold OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The upper critical threshold as an unsigned integer. - The value of this OID variable should be scaled by - inletPoleSensorDecimalDigits. For example, if the value is 1 and - inletPoleSensorDecimalDigits is 2, then actual value is 0.01. - The value is clamped if the scaled threshold exceeds 4294967295. It - is undefined for sensors which can have negative readings. - This parameter does not apply to sensors without numerical reading." - ::= { inletPoleSensorConfigurationEntry 23 } + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The upper critical threshold as an unsigned integer. + The value of this OID variable should be scaled by + inletPoleSensorDecimalDigits. For example, if the value is 1 and + inletPoleSensorDecimalDigits is 2, then actual value is 0.01. + The value is clamped if the scaled threshold exceeds 4294967295. It + is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { inletPoleSensorConfigurationEntry 23 } -inletPoleSensorUpperWarningThreshold OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The upper warning threshold as an unsigned integer. - The value of this OID variable should be scaled by - inletPoleSensorDecimalDigits. For example, if the value is 1 and - inletPoleSensorDecimalDigits is 2, then actual value is 0.01. - The value is clamped if the scaled threshold exceeds 4294967295. It - is undefined for sensors which can have negative readings. - This parameter does not apply to sensors without numerical reading." - ::= { inletPoleSensorConfigurationEntry 24 } +inletPoleSensorUpperWarningThreshold OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The upper warning threshold as an unsigned integer. + The value of this OID variable should be scaled by + inletPoleSensorDecimalDigits. For example, if the value is 1 and + inletPoleSensorDecimalDigits is 2, then actual value is 0.01. + The value is clamped if the scaled threshold exceeds 4294967295. It + is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { inletPoleSensorConfigurationEntry 24 } -inletPoleSensorEnabledThresholds OBJECT-TYPE - SYNTAX BITS{ - lowerCritical(0), - lowerWarning(1), - upperWarning(2), - upperCritical(3) - } - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "A bit string which indicates which thresholds are enabled. - This parameter does not apply to sensors without numerical reading." - ::= { inletPoleSensorConfigurationEntry 25 } +inletPoleSensorEnabledThresholds OBJECT-TYPE + SYNTAX BITS { lowerCritical(0), + lowerWarning(1), + upperWarning(2), + upperCritical(3) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "A bit string indicating which thresholds are enabled. + This parameter does not apply to sensors without numerical reading." + ::= { inletPoleSensorConfigurationEntry 25 } -inletPoleSensorSignedMaximum OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The largest possible reading as a signed integer. - The value of this OID variable should be scaled by - inletPoleSensorDecimalDigits. For example, if the value is 1 and - inletPoleSensorDecimalDigits is 2, then actual value is 0.01. - The value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647). - This parameter does not apply to sensors without numerical reading." - ::= { inletPoleSensorConfigurationEntry 26 } +inletPoleSensorSignedMaximum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The largest possible reading as a signed integer. + The value of this OID variable should be scaled by + inletPoleSensorDecimalDigits. For example, if the value is 1 and + inletPoleSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { inletPoleSensorConfigurationEntry 26 } -inletPoleSensorSignedMinimum OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The smallest possible reading as a signed integer. - The value of this OID variable should be scaled by - inletPoleSensorDecimalDigits. For example, if the value is 1 and - inletPoleSensorDecimalDigits is 2, then actual value is 0.01. - This value determines whether to use the signed or unsigned threshold - and value columns: If the minimum is below zero the sensor can have - negative readings and the signed columns should be used. - This parameter does not apply to sensors without numerical reading." - ::= { inletPoleSensorConfigurationEntry 27 } +inletPoleSensorSignedMinimum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The smallest possible reading as a signed integer. + The value of this OID variable should be scaled by + inletPoleSensorDecimalDigits. For example, if the value is 1 and + inletPoleSensorDecimalDigits is 2, then actual value is 0.01. + This value determines whether to use the signed or unsigned threshold + and value columns: If the minimum is below zero the sensor can have + negative readings and the signed columns should be used. + This parameter does not apply to sensors without numerical reading." + ::= { inletPoleSensorConfigurationEntry 27 } inletPoleSensorSignedLowerCriticalThreshold OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The lower critical threshold as a signed integer. - The value of this OID variable should be scaled by - inletPoleSensorDecimalDigits. For example, if the value is 1 and - inletPoleSensorDecimalDigits is 2, then actual value is 0.01. - The value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647). - This parameter does not apply to sensors without numerical reading." - ::= { inletPoleSensorConfigurationEntry 28 } + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The lower critical threshold as a signed integer. + The value of this OID variable should be scaled by + inletPoleSensorDecimalDigits. For example, if the value is 1 and + inletPoleSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { inletPoleSensorConfigurationEntry 28 } inletPoleSensorSignedLowerWarningThreshold OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The lower warning threshold as a signed integer. - The value of this OID variable should be scaled by - inletPoleSensorDecimalDigits. For example, if the value is 1 and - inletPoleSensorDecimalDigits is 2, then actual value is 0.01. - The value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647). - This parameter does not apply to sensors without numerical reading." - ::= { inletPoleSensorConfigurationEntry 29 } + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The lower warning threshold as a signed integer. + The value of this OID variable should be scaled by + inletPoleSensorDecimalDigits. For example, if the value is 1 and + inletPoleSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { inletPoleSensorConfigurationEntry 29 } inletPoleSensorSignedUpperCriticalThreshold OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The upper critical threshold as a signed integer. - The value of this OID variable should be scaled by - inletPoleSensorDecimalDigits. For example, if the value is 1 and - inletPoleSensorDecimalDigits is 2, then actual value is 0.01. - The value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647). - This parameter does not apply to sensors without numerical reading." - ::= { inletPoleSensorConfigurationEntry 30 } + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The upper critical threshold as a signed integer. + The value of this OID variable should be scaled by + inletPoleSensorDecimalDigits. For example, if the value is 1 and + inletPoleSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { inletPoleSensorConfigurationEntry 30 } inletPoleSensorSignedUpperWarningThreshold OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The upper warning threshold as a signed integer. - The value of this OID variable should be scaled by - inletPoleSensorDecimalDigits. For example, if the value is 1 and - inletPoleSensorDecimalDigits is 2, then actual value is 0.01. - The value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647). - This parameter does not apply to sensors without numerical reading." - ::= { inletPoleSensorConfigurationEntry 31 } + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The upper warning threshold as a signed integer. + The value of this OID variable should be scaled by + inletPoleSensorDecimalDigits. For example, if the value is 1 and + inletPoleSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { inletPoleSensorConfigurationEntry 31 } +-- overCurrentProtectorConfigurationTable: information and settings for overcurrent protectors +overCurrentProtectorConfigurationTable OBJECT-TYPE + SYNTAX SEQUENCE OF OverCurrentProtectorConfigurationEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of overcurrent protector configuration entries. The number of + entries is given by the value of overCurrentProtectorCount for the PDU." + ::= { overCurrentProtector 3 } --- the overCurrentProtectorConfiguration table +overCurrentProtectorConfigurationEntry OBJECT-TYPE + SYNTAX OverCurrentProtectorConfigurationEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing objects for a particular overcurrent protector." + INDEX { pduId, overCurrentProtectorIndex } + ::= { overCurrentProtectorConfigurationTable 1 } --- The overCurrentProtectorConfiguration table contains information on the PDU's overcurrent protectors. +OverCurrentProtectorConfigurationEntryStruct ::= SEQUENCE { + overCurrentProtectorIndex Integer32, + overCurrentProtectorLabel DisplayString, + overCurrentProtectorName DisplayString, + overCurrentProtectorType OverCurrentProtectorTypeEnumeration, + overCurrentProtectorRatedCurrent DisplayString, + overCurrentProtectorPoleCount Integer32, + overCurrentProtectorCapabilities BITS, + overCurrentProtectorPowerSource RowPointer + } +overCurrentProtectorIndex OBJECT-TYPE + SYNTAX Integer32(1..256) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A unique value for each overcurrent protector. Its value + ranges between 1 and the value of overCurrentProtectorCount." + ::= { overCurrentProtectorConfigurationEntry 1 } -overCurrentProtectorConfigurationTable OBJECT-TYPE - SYNTAX SEQUENCE OF OverCurrentProtectorConfigurationEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A list of overCurrentProtector configuration entries. The number of - entries is given by the value of overCurrentProtectorCount for the PDU." - ::= { overCurrentProtector 3 } +overCurrentProtectorLabel OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The label on the PDU identifying the overcurrent protector." + ::= { overCurrentProtectorConfigurationEntry 2 } -overCurrentProtectorConfigurationEntry OBJECT-TYPE - SYNTAX OverCurrentProtectorConfigurationEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "An entry containing objects for a particular overCurrentProtector." - INDEX { pduId, overCurrentProtectorIndex } - ::= { overCurrentProtectorConfigurationTable 1 } +overCurrentProtectorName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The user-defined name." + ::= { overCurrentProtectorConfigurationEntry 3 } -OverCurrentProtectorConfigurationEntryStruct ::= SEQUENCE { overCurrentProtectorIndex Integer32, - overCurrentProtectorLabel DisplayString, - overCurrentProtectorName DisplayString, - overCurrentProtectorType OverCurrentProtectorTypeEnumeration, - overCurrentProtectorRatedCurrent DisplayString, - overCurrentProtectorCapabilities BITS, - overCurrentProtectorPowerSource RowPointer - } +overCurrentProtectorType OBJECT-TYPE + SYNTAX OverCurrentProtectorTypeEnumeration + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The type of overcurrent protector." + ::= { overCurrentProtectorConfigurationEntry 4 } +overCurrentProtectorRatedCurrent OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The current rating." + ::= { overCurrentProtectorConfigurationEntry 5 } -overCurrentProtectorIndex OBJECT-TYPE - SYNTAX Integer32(1..256) - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A unique value for each overcurrent protector. Its value - ranges between 1 and the value of overCurrentProtectorCount." - ::= { overCurrentProtectorConfigurationEntry 1 } +overCurrentProtectorPoleCount OBJECT-TYPE + SYNTAX Integer32(1..3) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of overcurrent protector poles." + ::= { overCurrentProtectorConfigurationEntry 6 } -overCurrentProtectorLabel OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The label on the PDU identifying the overcurrent protector." - ::= { overCurrentProtectorConfigurationEntry 2 } +overCurrentProtectorCapabilities OBJECT-TYPE + SYNTAX BITS { rmsCurrent(0), + peakCurrent(1), + trip(14) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A bit string indicating which overcurrent protector sensors are available." + ::= { overCurrentProtectorConfigurationEntry 9 } -overCurrentProtectorName OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The user-defined name." - ::= { overCurrentProtectorConfigurationEntry 3 } +overCurrentProtectorPowerSource OBJECT-TYPE + SYNTAX RowPointer + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object allows discovery of how the PDU is wired. It indicates the + overcurrent protector's power source which can be one of the following: + - an inlet + - another overcurrent protector + - a transfer switch -overCurrentProtectorType OBJECT-TYPE - SYNTAX OverCurrentProtectorTypeEnumeration - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The type of overcurrent protector." - ::= { overCurrentProtectorConfigurationEntry 4 } + If the power source is an inlet, it contains the OID of + an inletLabel in the inletConfigurationTable. The indices of the OID can + then be used to reference other objects in the inlet tables. + If the power source is an overcurrent protector, it + contains the OID of an overCurrentProtectorLabel in the + overCurrentProtectorConfigurationTable. The indices of the OID can then be + used to reference other objects in the overcurrent protector tables. + If the power source is a transfer switch, it + contains the OID of a transferSwitchLabel in the + transferSwitchConfigurationTable. The indices of the OID can then be + used to reference other objects in the transfer switch tables." + ::= { overCurrentProtectorConfigurationEntry 10 } +-- overCurrentProtectorPoleConfigurationTable: overcurrent protector pole information -overCurrentProtectorRatedCurrent OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The current rating." - ::= { overCurrentProtectorConfigurationEntry 5 } +overCurrentProtectorPoleConfigurationTable OBJECT-TYPE + SYNTAX SEQUENCE OF OverCurrentProtectorPoleConfigurationEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of overcurrent protector pole configuration entries. The number of + entries is given by the value of overCurrentProtectorPoleCount." + ::= { overCurrentProtector 5 } +overCurrentProtectorPoleConfigurationEntry OBJECT-TYPE + SYNTAX OverCurrentProtectorPoleConfigurationEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing parameters for a particular overcurrent protector pole." + INDEX { pduId, overCurrentProtectorIndex, overCurrentProtectorPoleIndex } + ::= { overCurrentProtectorPoleConfigurationTable 1 } +OverCurrentProtectorPoleConfigurationEntryStruct ::= SEQUENCE { + overCurrentProtectorPoleIndex Integer32, + overCurrentProtectorPoleLine LineEnumeration, + overCurrentProtectorPoleInNode Integer32, + overCurrentProtectorPoleOutNode Integer32 + } -overCurrentProtectorCapabilities OBJECT-TYPE - SYNTAX BITS{ - rmsCurrent(0), - peakCurrent(1), - trip(14) - } - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "A bit string which indicates which overcurrent protector sensors are available." - ::= { overCurrentProtectorConfigurationEntry 9 } +overCurrentProtectorPoleIndex OBJECT-TYPE + SYNTAX Integer32(1..256) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A unique value for each overcurrent protector pole. Its value + ranges between 1 and the value of overCurrentProtectorPoleCount." + ::= { overCurrentProtectorPoleConfigurationEntry 1 } -overCurrentProtectorPowerSource OBJECT-TYPE - SYNTAX RowPointer - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "This object allows discovery of how the PDU is wired. It indicates the - overCurrentProtector's power source which can one of the following: - overCurrentProtector - transfer switch - inlet +overCurrentProtectorPoleLine OBJECT-TYPE + SYNTAX LineEnumeration + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The phase for this overcurrent protector pole." + ::= { overCurrentProtectorPoleConfigurationEntry 2 } - If the power source is an OverCurrentProtector, it - contains the OID of an overCurrentProtectorLabel in the - overCurrentProtectorConfiguration Table. The index of the OID can then be - used to reference other objects in the overCurrentProtectorConfigurationTable. +overCurrentProtectorPoleInNode OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The node to which this overcurrent protector pole input is connected" + ::= { overCurrentProtectorPoleConfigurationEntry 3 } - If the power source is an inlet, it contains the OID of - an inletLabel in the inletConfigurationTable. The index of the OID can - then be used to reference other objects in the inletConfigurationTable. +overCurrentProtectorPoleOutNode OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The node to which this overcurrent protector pole output is connected" + ::= { overCurrentProtectorPoleConfigurationEntry 4 } - If the power source is a transferSwitch, it - contains the OID of a transferSwitchLabel in the - transferSwitchConfiguration Table. The index of the OID can then be - used to reference other objects in the transferSwitchConfigurationTable. - " - ::= { overCurrentProtectorConfigurationEntry 10 } +-- overCurrentProtectorSensorConfigurationTable: information and settings for OCP sensors +overCurrentProtectorSensorConfigurationTable OBJECT-TYPE + SYNTAX SEQUENCE OF OverCurrentProtectorSensorConfigurationEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of overcurrent protector sensor configuration entries." + ::= { overCurrentProtector 4 } - - --- The overCurrentProtectorSensorConfiguration table contains information on the PDU's overcurrent protector Sensors. - - -overCurrentProtectorSensorConfigurationTable OBJECT-TYPE - SYNTAX SEQUENCE OF OverCurrentProtectorSensorConfigurationEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A list of overCurrentProtectorSensor configuration entries." - ::= { overCurrentProtector 4 } - -overCurrentProtectorSensorConfigurationEntry OBJECT-TYPE - SYNTAX OverCurrentProtectorSensorConfigurationEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "An overCurrentProtectorSensor entry containing objects for a - particular overCurrentProtector Sensor." - INDEX { pduId, overCurrentProtectorIndex, sensorType } - ::= { overCurrentProtectorSensorConfigurationTable 1 } +overCurrentProtectorSensorConfigurationEntry OBJECT-TYPE + SYNTAX OverCurrentProtectorSensorConfigurationEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An overcurrent protector sensor entry containing objects for a + particular overcurrent protector sensor." + INDEX { pduId, overCurrentProtectorIndex, sensorType } + ::= { overCurrentProtectorSensorConfigurationTable 1 } OverCurrentProtectorSensorConfigurationEntryStruct ::= SEQUENCE { - overCurrentProtectorSensorLogAvailable TruthValue, - overCurrentProtectorSensorUnits SensorUnitsEnumeration, - overCurrentProtectorSensorDecimalDigits Unsigned32, - overCurrentProtectorSensorAccuracy HundredthsOfAPercentage, - overCurrentProtectorSensorResolution Unsigned32, - overCurrentProtectorSensorTolerance Unsigned32, - overCurrentProtectorSensorMaximum Unsigned32, - overCurrentProtectorSensorMinimum Unsigned32, - overCurrentProtectorSensorHysteresis Unsigned32, - overCurrentProtectorSensorStateChangeDelay Unsigned32, - overCurrentProtectorSensorLowerCriticalThreshold Unsigned32, - overCurrentProtectorSensorLowerWarningThreshold Unsigned32, - overCurrentProtectorSensorUpperCriticalThreshold Unsigned32, - overCurrentProtectorSensorUpperWarningThreshold Unsigned32, - overCurrentProtectorSensorEnabledThresholds BITS, - overCurrentProtectorSensorSignedMaximum Integer32, - overCurrentProtectorSensorSignedMinimum Integer32, - overCurrentProtectorSensorSignedLowerCriticalThreshold Integer32, - overCurrentProtectorSensorSignedLowerWarningThreshold Integer32, - overCurrentProtectorSensorSignedUpperCriticalThreshold Integer32, - overCurrentProtectorSensorSignedUpperWarningThreshold Integer32 - } + overCurrentProtectorSensorLogAvailable TruthValue, + overCurrentProtectorSensorUnits SensorUnitsEnumeration, + overCurrentProtectorSensorDecimalDigits Unsigned32, + overCurrentProtectorSensorAccuracy HundredthsOfAPercentage, + overCurrentProtectorSensorResolution Unsigned32, + overCurrentProtectorSensorTolerance Unsigned32, + overCurrentProtectorSensorMaximum Unsigned32, + overCurrentProtectorSensorMinimum Unsigned32, + overCurrentProtectorSensorHysteresis Unsigned32, + overCurrentProtectorSensorStateChangeDelay Unsigned32, + overCurrentProtectorSensorLowerCriticalThreshold Unsigned32, + overCurrentProtectorSensorLowerWarningThreshold Unsigned32, + overCurrentProtectorSensorUpperCriticalThreshold Unsigned32, + overCurrentProtectorSensorUpperWarningThreshold Unsigned32, + overCurrentProtectorSensorEnabledThresholds BITS, + overCurrentProtectorSensorSignedMaximum Integer32, + overCurrentProtectorSensorSignedMinimum Integer32, + overCurrentProtectorSensorSignedLowerCriticalThreshold Integer32, + overCurrentProtectorSensorSignedLowerWarningThreshold Integer32, + overCurrentProtectorSensorSignedUpperCriticalThreshold Integer32, + overCurrentProtectorSensorSignedUpperWarningThreshold Integer32 + } overCurrentProtectorSensorLogAvailable OBJECT-TYPE - SYNTAX TruthValue - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "Is logging available for this sensor?" - ::= { overCurrentProtectorSensorConfigurationEntry 4 } + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is data logging enabled for this sensor?" + ::= { overCurrentProtectorSensorConfigurationEntry 4 } -overCurrentProtectorSensorUnits OBJECT-TYPE - SYNTAX SensorUnitsEnumeration - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The base units - This parameter does not apply to sensors without numerical reading, - e.g. trip sensors." - ::= { overCurrentProtectorSensorConfigurationEntry 6 } +overCurrentProtectorSensorUnits OBJECT-TYPE + SYNTAX SensorUnitsEnumeration + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The unit in which the sensor reading is reported. + This parameter does not apply to sensors without numerical reading." + ::= { overCurrentProtectorSensorConfigurationEntry 6 } overCurrentProtectorSensorDecimalDigits OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The number of digits displayed to the right of the decimal point. - This parameter does not apply to sensors without numerical reading, - e.g. trip sensors." - ::= { overCurrentProtectorSensorConfigurationEntry 7 } + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of digits displayed to the right of the decimal point. + This parameter does not apply to sensors without numerical reading." + ::= { overCurrentProtectorSensorConfigurationEntry 7 } -overCurrentProtectorSensorAccuracy OBJECT-TYPE - SYNTAX HundredthsOfAPercentage - MAX-ACCESS read-only - STATUS deprecated - DESCRIPTION - "The accuracy: how close (in percent) the measurement is to the actual value - This parameter does not apply to sensors without numerical reading, - e.g. trip sensors." - ::= { overCurrentProtectorSensorConfigurationEntry 8 } +overCurrentProtectorSensorAccuracy OBJECT-TYPE + SYNTAX HundredthsOfAPercentage + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The accuracy: the maximum relative difference (in percent) between + measurement and the actual value. + This parameter does not apply to sensors without numerical reading." + ::= { overCurrentProtectorSensorConfigurationEntry 8 } -overCurrentProtectorSensorResolution OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The resolution: the minimum difference between any two measured values - The value of this OID variable should be scaled by - overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and - overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01. - This parameter does not apply to sensors without numerical reading, - e.g. trip sensors." - ::= { overCurrentProtectorSensorConfigurationEntry 9 } +overCurrentProtectorSensorResolution OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The resolution: the minimum difference between any two measured values + The value of this OID variable should be scaled by + overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and + overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01. + This parameter does not apply to sensors without numerical reading." + ::= { overCurrentProtectorSensorConfigurationEntry 9 } -overCurrentProtectorSensorTolerance OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS deprecated - DESCRIPTION - "The resolution: the difference between a sensor value and the actual value - The value of this OID variable should be scaled by - (overCurrentProtectorSensorDecimalDigits + 1). For example, if the value is 50 and - overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.05. - This parameter does not apply to sensors without numerical reading, - e.g. trip sensors." - ::= { overCurrentProtectorSensorConfigurationEntry 10 } +overCurrentProtectorSensorTolerance OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The tolerance: the maximum difference between measurement and the + actual value. The value of this OID variable should be scaled by + (overCurrentProtectorSensorDecimalDigits + 1). For example, if the value is 50 and + overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.05. + This parameter does not apply to sensors without numerical reading." + ::= { overCurrentProtectorSensorConfigurationEntry 10 } -overCurrentProtectorSensorMaximum OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The largest possible reading as an unsigned integer. - The value of this OID variable should be scaled by - overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and - overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01. - The value is clamped if the scaled maximum exceeds 4294967295. It - is undefined for sensors which can have negative readings. - This parameter does not apply to sensors without numerical reading, - e.g. trip sensors." - ::= { overCurrentProtectorSensorConfigurationEntry 11 } +overCurrentProtectorSensorMaximum OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The largest possible reading as an unsigned integer. + The value of this OID variable should be scaled by + overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and + overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01. + The value is clamped if the scaled maximum exceeds 4294967295. It + is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { overCurrentProtectorSensorConfigurationEntry 11 } -overCurrentProtectorSensorMinimum OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The smallest possible reading as an unsigned integer. - The value of this OID variable should be scaled by - overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and - overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01. - The value is undefined for sensors which can have negative readings. - This parameter does not apply to sensors without numerical reading, - e.g. trip sensors." - ::= { overCurrentProtectorSensorConfigurationEntry 12 } +overCurrentProtectorSensorMinimum OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The smallest possible reading as an unsigned integer. + The value of this OID variable should be scaled by + overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and + overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { overCurrentProtectorSensorConfigurationEntry 12 } -overCurrentProtectorSensorHysteresis OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The hysteresis used for deassertions - The value of this OID variable should be scaled by - overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and - overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01. - This parameter does not apply to sensors without numerical reading, - e.g. trip sensors." - ::= { overCurrentProtectorSensorConfigurationEntry 13 } +overCurrentProtectorSensorHysteresis OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The hysteresis used when crossing a threshold towards the normal state. + The value of this OID variable should be scaled by + overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and + overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01. + This parameter does not apply to sensors without numerical reading." + ::= { overCurrentProtectorSensorConfigurationEntry 13 } overCurrentProtectorSensorStateChangeDelay OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The delay measured in samples before a state is asserted. - If the value is zero, then the state is asserted as soon as - it is detected; if it is non-zero, say n, then the assertion - condition must exist for n+1 consecutive samples before the corresponding - assertion event is reported. - This parameter does not apply to sensors without numerical reading, - e.g. trip sensors." - ::= { overCurrentProtectorSensorConfigurationEntry 14 } + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The delay measured in samples before a state is asserted. + If the value is zero, then the state is asserted as soon as + it is detected; if it is non-zero, say n, then the assertion + condition must exist for n+1 consecutive samples before the + event is reported. + This parameter does not apply to sensors without numerical reading." + ::= { overCurrentProtectorSensorConfigurationEntry 14 } overCurrentProtectorSensorLowerCriticalThreshold OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The lower critical threshold as an unsigned integer. - The value of this OID variable should be scaled by - overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and - overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01. - The value is clamped if the scaled threshold exceeds 4294967295. It - is undefined for sensors which can have negative readings. - This parameter does not apply to sensors without numerical reading, - e.g. trip sensors." - ::= { overCurrentProtectorSensorConfigurationEntry 21 } + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The lower critical threshold as an unsigned integer. + The value of this OID variable should be scaled by + overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and + overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01. + The value is clamped if the scaled threshold exceeds 4294967295. It + is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { overCurrentProtectorSensorConfigurationEntry 21 } overCurrentProtectorSensorLowerWarningThreshold OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The lower warning threshold as an unsigned integer. - The value of this OID variable should be scaled by - overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and - overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01. - The value is clamped if the scaled threshold exceeds 4294967295. It - is undefined for sensors which can have negative readings. - This parameter does not apply to sensors without numerical reading, - e.g. trip sensors." - ::= { overCurrentProtectorSensorConfigurationEntry 22 } + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The lower warning threshold as an unsigned integer. + The value of this OID variable should be scaled by + overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and + overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01. + The value is clamped if the scaled threshold exceeds 4294967295. It + is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { overCurrentProtectorSensorConfigurationEntry 22 } overCurrentProtectorSensorUpperCriticalThreshold OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The upper critical threshold as an unsigned integer. - The value of this OID variable should be scaled by - overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and - overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01. - The value is clamped if the scaled threshold exceeds 4294967295. It - is undefined for sensors which can have negative readings. - This parameter does not apply to sensors without numerical reading, - e.g. trip sensors." - ::= { overCurrentProtectorSensorConfigurationEntry 23 } + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The upper critical threshold as an unsigned integer. + The value of this OID variable should be scaled by + overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and + overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01. + The value is clamped if the scaled threshold exceeds 4294967295. It + is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { overCurrentProtectorSensorConfigurationEntry 23 } overCurrentProtectorSensorUpperWarningThreshold OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The upper warning threshold as an unsigned integer. - The value of this OID variable should be scaled by - overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and - overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01. - The value is clamped if the scaled threshold exceeds 4294967295. It - is undefined for sensors which can have negative readings. - This parameter does not apply to sensors without numerical reading, - e.g. trip sensors." - ::= { overCurrentProtectorSensorConfigurationEntry 24 } + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The upper warning threshold as an unsigned integer. + The value of this OID variable should be scaled by + overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and + overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01. + The value is clamped if the scaled threshold exceeds 4294967295. It + is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { overCurrentProtectorSensorConfigurationEntry 24 } overCurrentProtectorSensorEnabledThresholds OBJECT-TYPE - SYNTAX BITS{ - lowerCritical(0), - lowerWarning(1), - upperWarning(2), - upperCritical(3) - } - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "A bit string which indicates which thresholds are enabled. - This parameter does not apply to sensors without numerical reading, - e.g. trip sensors." - ::= { overCurrentProtectorSensorConfigurationEntry 25} + SYNTAX BITS { lowerCritical(0), + lowerWarning(1), + upperWarning(2), + upperCritical(3) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "A bit string indicating which thresholds are enabled. + This parameter does not apply to sensors without numerical reading." + ::= { overCurrentProtectorSensorConfigurationEntry 25} overCurrentProtectorSensorSignedMaximum OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The largest possible reading as a signed integer. - The value of this OID variable should be scaled by - overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and - overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01. - The value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647). - This parameter does not apply to sensors without numerical reading, - e.g. trip sensors." - ::= { overCurrentProtectorSensorConfigurationEntry 26 } + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The largest possible reading as a signed integer. + The value of this OID variable should be scaled by + overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and + overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { overCurrentProtectorSensorConfigurationEntry 26 } overCurrentProtectorSensorSignedMinimum OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The smallest possible reading as a signed integer. - The value of this OID variable should be scaled by - overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and - overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01. - This value determines whether to use the signed or unsigned threshold - and value columns: If the minimum is below zero the sensor can have - negative readings and the signed columns should be used. - This parameter does not apply to sensors without numerical reading, - e.g. trip sensors." - ::= { overCurrentProtectorSensorConfigurationEntry 27 } + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The smallest possible reading as a signed integer. + The value of this OID variable should be scaled by + overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and + overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01. + This value determines whether to use the signed or unsigned threshold + and value columns: If the minimum is below zero the sensor can have + negative readings and the signed columns should be used. + This parameter does not apply to sensors without numerical reading." + ::= { overCurrentProtectorSensorConfigurationEntry 27 } overCurrentProtectorSensorSignedLowerCriticalThreshold OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The lower critical threshold as a signed integer. - The value of this OID variable should be scaled by - overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and - overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01. - The value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647). - This parameter does not apply to sensors without numerical reading, - e.g. trip sensors." - ::= { overCurrentProtectorSensorConfigurationEntry 28 } + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The lower critical threshold as a signed integer. + The value of this OID variable should be scaled by + overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and + overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { overCurrentProtectorSensorConfigurationEntry 28 } overCurrentProtectorSensorSignedLowerWarningThreshold OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The lower warning threshold as a signed integer. - The value of this OID variable should be scaled by - overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and - overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01. - The value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647). - This parameter does not apply to sensors without numerical reading, - e.g. trip sensors." - ::= { overCurrentProtectorSensorConfigurationEntry 29 } + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The lower warning threshold as a signed integer. + The value of this OID variable should be scaled by + overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and + overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { overCurrentProtectorSensorConfigurationEntry 29 } overCurrentProtectorSensorSignedUpperCriticalThreshold OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The upper critical threshold as a signed integer. - The value of this OID variable should be scaled by - overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and - overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01. - The value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647). - This parameter does not apply to sensors without numerical reading, - e.g. trip sensors." - ::= { overCurrentProtectorSensorConfigurationEntry 30 } + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The upper critical threshold as a signed integer. + The value of this OID variable should be scaled by + overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and + overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { overCurrentProtectorSensorConfigurationEntry 30 } overCurrentProtectorSensorSignedUpperWarningThreshold OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The upper warning threshold as a signed integer. - The value of this OID variable should be scaled by - overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and - overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01. - The value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647). - This parameter does not apply to sensors without numerical reading, - e.g. trip sensors." - ::= { overCurrentProtectorSensorConfigurationEntry 31 } + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The upper warning threshold as a signed integer. + The value of this OID variable should be scaled by + overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and + overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { overCurrentProtectorSensorConfigurationEntry 31 } +-- outletConfigurationTable: outlet information and settings +outletConfigurationTable OBJECT-TYPE + SYNTAX SEQUENCE OF OutletConfigurationEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of outlet configuration entries. The number of + entries is given by the value of outletCount for the PDU." + ::= { outlets 3 } --- the outletConfiguration table - --- The outletConfiguration table contains information on the PDU's outlets. - - -outletConfigurationTable OBJECT-TYPE - SYNTAX SEQUENCE OF OutletConfigurationEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A list of outlet configuration entries. The number of - entries is given by the value of outletCount for the PDU." - ::= { outlets 3 } - -outletConfigurationEntry OBJECT-TYPE - SYNTAX OutletConfigurationEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "An outlet entry containing parameters for a particular outlet." - INDEX { pduId, outletId } - ::= { outletConfigurationTable 1 } +outletConfigurationEntry OBJECT-TYPE + SYNTAX OutletConfigurationEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An outlet entry containing parameters for a particular outlet." + INDEX { pduId, outletId } + ::= { outletConfigurationTable 1 } OutletConfigurationEntryStruct ::= SEQUENCE { - outletId Integer32, - outletLabel DisplayString, - outletName DisplayString, - outletReceptacle ReceptacleTypeEnumeration, - outletPoleCount Integer32, - outletRatedVoltage DisplayString, - outletRatedCurrent DisplayString, - outletRatedVA DisplayString, - outletDeviceCapabilities BITS, - outletPoleCapabilities BITS, - outletPowerCyclingPowerOffPeriod Unsigned32, - outletStateOnStartup OutletStateOnStartupEnumeration, - outletUseGlobalPowerCyclingPowerOffPeriod TruthValue, - outletSwitchable TruthValue, - outletReceptacleDescriptor DisplayString, - outletNonCritical TruthValue, - outletSequenceDelay Unsigned32, - outletPowerSource RowPointer - } + outletId Integer32, + outletLabel DisplayString, + outletName DisplayString, + outletReceptacle ReceptacleTypeEnumeration, + outletPoleCount Integer32, + outletRatedVoltage DisplayString, + outletRatedCurrent DisplayString, + outletRatedVA DisplayString, + outletDeviceCapabilities BITS, + outletPoleCapabilities BITS, + outletPowerCyclingPowerOffPeriod Unsigned32, + outletStateOnStartup OutletStateOnStartupEnumeration, + outletUseGlobalPowerCyclingPowerOffPeriod TruthValue, + outletSwitchable TruthValue, + outletReceptacleDescriptor DisplayString, + outletNonCritical TruthValue, + outletSequenceDelay Unsigned32, + outletPowerSource RowPointer + } -outletId OBJECT-TYPE - SYNTAX Integer32(1..256) - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A unique value for each outlet. Its value - ranges between 1 and the value of outletCount." - ::= { outletConfigurationEntry 1 } +outletId OBJECT-TYPE + SYNTAX Integer32(1..256) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A unique value for each outlet. Its value + ranges between 1 and the value of outletCount." + ::= { outletConfigurationEntry 1 } +outletLabel OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The label on the PDU identifying the outlet." + ::= { outletConfigurationEntry 2 } -outletLabel OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The label on the PDU identifying the outlet." - ::= { outletConfigurationEntry 2 } +outletName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The user-defined name." + ::= { outletConfigurationEntry 3 } -outletName OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The user-defined name." - ::= { outletConfigurationEntry 3 } +outletReceptacle OBJECT-TYPE + SYNTAX ReceptacleTypeEnumeration + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The receptacle type. + Note: ReceptacleTypeEnumeration is no longer updated, unlisted receptacles + will be listed as receptacleOTHER. Use outletReceptacleDescriptor to + reliably determine the receptacle type." + ::= { outletConfigurationEntry 4 } -outletReceptacle OBJECT-TYPE - SYNTAX ReceptacleTypeEnumeration - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The plug." - ::= { outletConfigurationEntry 4 } +outletPoleCount OBJECT-TYPE + SYNTAX Integer32(2..4) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of poles." + ::= { outletConfigurationEntry 5 } -outletPoleCount OBJECT-TYPE - SYNTAX Integer32(2..4) - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The number of poles." - ::= { outletConfigurationEntry 5 } +outletRatedVoltage OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The outlet voltage rating." + ::= { outletConfigurationEntry 6 } -outletRatedVoltage OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The outlet voltage rating." - ::= { outletConfigurationEntry 6 } +outletRatedCurrent OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The outlet current rating." + ::= { outletConfigurationEntry 7 } +outletRatedVA OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The outlet VA (VoltAmps) rating." + ::= { outletConfigurationEntry 8 } -outletRatedCurrent OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The outlet current rating." - ::= { outletConfigurationEntry 7 } +outletDeviceCapabilities OBJECT-TYPE + SYNTAX BITS { rmsCurrent(0), + peakCurrent(1), + unbalancedCurrent(2), + rmsVoltage(3), + activePower(4), + apparentPower(5), + powerFactor(6), + activeEnergy(7), + apparentEnergy(8), + onOff(13), + frequency(22), + phaseAngle(23) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A bit string indicating which outlet sensors are available." + ::= { outletConfigurationEntry 10 } +outletPoleCapabilities OBJECT-TYPE + SYNTAX BITS { rmsCurrent(0), + peakCurrent(1), + rmsVoltage(3), + activePower(4), + apparentPower(5), + powerFactor(6), + activeEnergy(7), + apparentEnergy(8), + rmsVoltageLN(24) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A bit string indicating which outlet pole sensors are available." + ::= { outletConfigurationEntry 11 } -outletRatedVA OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The outlet VA (VoltAmps) rating." - ::= { outletConfigurationEntry 8 } +outletPowerCyclingPowerOffPeriod OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The power-off period when an outlet is cycled. + Overrides the global value if outletUseGlobalPowerCyclingPowerOffPeriod + is false. + Specified in seconds, 1 <= value <= 3600." + ::= { outletConfigurationEntry 12 } +outletStateOnStartup OBJECT-TYPE + SYNTAX OutletStateOnStartupEnumeration + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The outlet state on device startup. + This value is ignored if relayBehaviorOnPowerLoss is set to latching." + ::= { outletConfigurationEntry 13 } +outletUseGlobalPowerCyclingPowerOffPeriod OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Indicates which power-off period to use when the outlet is cycled: + - true: use globalOutletPowerCyclingPowerOffPeriod + - false: use outletPowerCyclingPowerOffPeriod" + ::= { outletConfigurationEntry 14 } -outletDeviceCapabilities OBJECT-TYPE - SYNTAX BITS{ - rmsCurrent(0), - peakCurrent(1), - unbalancedCurrent(2), - rmsVoltage(3), - activePower(4), - apparentPower(5), - powerFactor(6), - activeEnergy(7), - apparentEnergy(8), - onOff(13), - frequency(22), - phaseAngle(23) - } - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "A bit string which indicates which outlet sensors are available." - ::= { outletConfigurationEntry 10 } +outletSwitchable OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Is this outlet switchable?" + ::= { outletConfigurationEntry 28 } -outletPoleCapabilities OBJECT-TYPE - SYNTAX BITS{ - rmsCurrent(0), - peakCurrent(1), - rmsVoltage(3), - activePower(4), - apparentPower(5), - powerFactor(6), - activeEnergy(7), - apparentEnergy(8), - rmsVoltageLN(24) - } - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "A bit string which indicates which outlet pole sensors are available." - ::= { outletConfigurationEntry 11 } +outletReceptacleDescriptor OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The outlet receptacle type as a string." + ::= { outletConfigurationEntry 29 } +outletNonCritical OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is this outlet non-critical? Non-critical outlets will be switched + off when load shedding is enabled." + ::= { outletConfigurationEntry 30 } -outletPowerCyclingPowerOffPeriod OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The power-off period when an outlet is cycled; - overrides the global value; - specified in seconds; - 0 <= value <= 3600 seconds." - ::= { outletConfigurationEntry 12 } +outletSequenceDelay OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The time interval between switching on this outlet and the next outlet in the + outlet sequence. + This applies to the following operations. + 1) Switch all outlets on operation is executed + 2) Power to the PDU is cycled + It is specified in seconds, 0 <= value <= 3600 seconds. + The effective time interval used can never be less than the inrushGuardDelay + defined in the unitConfigurationTable." + ::= { outletConfigurationEntry 32 } +outletPowerSource OBJECT-TYPE + SYNTAX RowPointer + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object allows discovery of how the PDU is wired. It indicates the + outlet's power source which can one of the following: + - an inlet + - an overcurrent protector + - a transfer switch -outletStateOnStartup OBJECT-TYPE - SYNTAX OutletStateOnStartupEnumeration - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The outlet state on device startup; - overrides the global value. - Note that this value is ignored if - relayBehaviorOnPowerLoss is set to latching." - ::= { outletConfigurationEntry 13} + If the power source is an inlet, it contains the OID of + an inletLabel in the inletConfigurationTable. The indices of the OID can + then be used to reference other objects in the inlet tables. + If the power source is an overcurrent protector, it + contains the OID of an overCurrentProtectorLabel in the + overCurrentProtectorConfigurationTable. The indices of the OID can then be + used to reference other objects in the overcurrent protector tables. -outletUseGlobalPowerCyclingPowerOffPeriod OBJECT-TYPE - SYNTAX TruthValue - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "If this true, then use globalOutletPowerCyclingPowerOffPeriod." - ::= { outletConfigurationEntry 14 } + If the power source is a transfer switch, it + contains the OID of a transferSwitchLabel in the + transferSwitchConfigurationTable. The indices of the OID can then be + used to reference other objects in the transfer switch tables." + ::= { outletConfigurationEntry 33} +-- outetPoleConfigurationTable: outlet pole information +outletPoleConfigurationTable OBJECT-TYPE + SYNTAX SEQUENCE OF OutletPoleConfigurationEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of outlet pole configuration entries. The number of + entries is given by the value of outletPoleCount for the PDU." + ::= { outlets 5 } +outletPoleConfigurationEntry OBJECT-TYPE + SYNTAX OutletPoleConfigurationEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing parameters for a particular outlet pole." + INDEX { pduId, outletId, outletPoleIndex } + ::= { outletPoleConfigurationTable 1 } -outletSwitchable OBJECT-TYPE - SYNTAX TruthValue - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "Is this outlet switchable?" - ::= { outletConfigurationEntry 28 } +OutletPoleConfigurationEntryStruct ::= SEQUENCE { + outletPoleLine LineEnumeration, + outletPoleNode Integer32 + } +outletPoleLine OBJECT-TYPE + SYNTAX LineEnumeration + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The phase for this outlet pole." + ::= { outletPoleConfigurationEntry 1 } -outletReceptacleDescriptor OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "Description of the Receptacle" - ::= { outletConfigurationEntry 29 } +outletPoleNode OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The node to which this outlet pole is connected" + ::= { outletPoleConfigurationEntry 2 } +-- outletSensorConfigurationTable: information and settings for outlet sensors -outletNonCritical OBJECT-TYPE - SYNTAX TruthValue - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "Is this outlet non-critical?" - ::= { outletConfigurationEntry 30 } +outletSensorConfigurationTable OBJECT-TYPE + SYNTAX SEQUENCE OF OutletSensorConfigurationEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of outlet sensor configuration entries." + ::= { outlets 4 } - - - - -outletSequenceDelay OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The time interval between switching on this outlet and the next outlet in the - outlet sequence. - This applies to the following operations. - 1) Switch all outlets on operation is executed - 2) Power to the PDU is cycledThis applies only when all outlets are being switched on or cycled. - It is specified in seconds; - 1 <= value <= 3600 seconds. - The actual time interval used can never be less than the inrushGuardDelay defined - in the unitConfigurationTable. - Examples: - 1) inrush Guard Delay is 2 seconds and outletSequenceDelay is 5 seconds. - The time interval will be 5 seconds - 2) inrush Guard Delay is 5 seconds and outletSequenceDelay is 2 seconds. - The time interval will be 5 seconds - " - ::= { outletConfigurationEntry 32 } - - -outletPowerSource OBJECT-TYPE - SYNTAX RowPointer - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "This object allows discovery of how the PDU is wired. It indicates the - outlet's power source which can one of the following: - overCurrentProtector - transfer switch - inlet - - If the power source is an OverCurrentProtector, it - contains the OID of an overCurrentProtectorLabel in the - overCurrentProtectorConfiguration Table. The index of the OID can then be - used to reference other objects in the overCurrentProtectorConfigurationTable. - - If the power source is an inlet, it contains the OID of - an inletLabel in the inletConfigurationTable. The index of the OID can - then be used to reference other objects in the inletConfigurationTable. - - If the power source is a transferSwitch, it - contains the OID of a transferSwitchLabel in the - transferSwitchConfiguration Table. The index of the OID can then be - used to reference other objects in the transferSwitchConfigurationTable. - - " - ::= { outletConfigurationEntry 33} - - - --- The outletSensorConfiguration table contains information on the PDU's inlet Sensors. - - -outletSensorConfigurationTable OBJECT-TYPE - SYNTAX SEQUENCE OF OutletSensorConfigurationEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A list of outlet configuration entries. The number of - entries is given by the value of outletCount for the PDU." - ::= { outlets 4 } - -outletSensorConfigurationEntry OBJECT-TYPE - SYNTAX OutletSensorConfigurationEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "An entry containing parameters for an outlet sensor." - INDEX { pduId, outletId,sensorType } - ::= { outletSensorConfigurationTable 1 } +outletSensorConfigurationEntry OBJECT-TYPE + SYNTAX OutletSensorConfigurationEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing parameters for an outlet sensor." + INDEX { pduId, outletId, sensorType } + ::= { outletSensorConfigurationTable 1 } OutletSensorConfigurationEntryStruct ::= SEQUENCE { - outletSensorLogAvailable TruthValue, - outletSensorUnits SensorUnitsEnumeration, - outletSensorDecimalDigits Unsigned32, - outletSensorAccuracy HundredthsOfAPercentage, - outletSensorResolution Unsigned32, - outletSensorTolerance Unsigned32, - outletSensorMaximum Unsigned32, - outletSensorMinimum Unsigned32, - outletSensorHysteresis Unsigned32, - outletSensorStateChangeDelay Unsigned32, - outletSensorLowerCriticalThreshold Unsigned32, - outletSensorLowerWarningThreshold Unsigned32, - outletSensorUpperCriticalThreshold Unsigned32, - outletSensorUpperWarningThreshold Unsigned32, - outletSensorEnabledThresholds BITS, - outletSensorSignedMaximum Integer32, - outletSensorSignedMinimum Integer32, - outletSensorSignedLowerCriticalThreshold Integer32, - outletSensorSignedLowerWarningThreshold Integer32, - outletSensorSignedUpperCriticalThreshold Integer32, - outletSensorSignedUpperWarningThreshold Integer32 - } + outletSensorLogAvailable TruthValue, + outletSensorUnits SensorUnitsEnumeration, + outletSensorDecimalDigits Unsigned32, + outletSensorAccuracy HundredthsOfAPercentage, + outletSensorResolution Unsigned32, + outletSensorTolerance Unsigned32, + outletSensorMaximum Unsigned32, + outletSensorMinimum Unsigned32, + outletSensorHysteresis Unsigned32, + outletSensorStateChangeDelay Unsigned32, + outletSensorLowerCriticalThreshold Unsigned32, + outletSensorLowerWarningThreshold Unsigned32, + outletSensorUpperCriticalThreshold Unsigned32, + outletSensorUpperWarningThreshold Unsigned32, + outletSensorEnabledThresholds BITS, + outletSensorSignedMaximum Integer32, + outletSensorSignedMinimum Integer32, + outletSensorSignedLowerCriticalThreshold Integer32, + outletSensorSignedLowerWarningThreshold Integer32, + outletSensorSignedUpperCriticalThreshold Integer32, + outletSensorSignedUpperWarningThreshold Integer32 + } -outletSensorLogAvailable OBJECT-TYPE - SYNTAX TruthValue - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "Is logging available for this sensor?" - ::= { outletSensorConfigurationEntry 4 } +outletSensorLogAvailable OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is data logging enabled for this sensor?" + ::= { outletSensorConfigurationEntry 4 } -outletSensorUnits OBJECT-TYPE - SYNTAX SensorUnitsEnumeration - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The base units. - This parameter does not apply to sensors without numerical reading, - e.g. outlet state sensors." - ::= { outletSensorConfigurationEntry 6 } +outletSensorUnits OBJECT-TYPE + SYNTAX SensorUnitsEnumeration + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The unit in which the sensor reading is reported. + This parameter does not apply to sensors without numerical reading." + ::= { outletSensorConfigurationEntry 6 } -outletSensorDecimalDigits OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The number of digits displayed to the right of the decimal point - This parameter does not apply to sensors without numerical reading, - e.g. outlet state sensors." - ::= { outletSensorConfigurationEntry 7 } +outletSensorDecimalDigits OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of digits displayed to the right of the decimal point + This parameter does not apply to sensors without numerical reading." + ::= { outletSensorConfigurationEntry 7 } -outletSensorAccuracy OBJECT-TYPE - SYNTAX HundredthsOfAPercentage - MAX-ACCESS read-only - STATUS deprecated - DESCRIPTION - "The accuracy: how close (in percent) the measurement is to the actual value - This parameter does not apply to sensors without numerical reading, - e.g. outlet state sensors." - ::= { outletSensorConfigurationEntry 8 } +outletSensorAccuracy OBJECT-TYPE + SYNTAX HundredthsOfAPercentage + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The accuracy: the maximum relative difference (in percent) between + measurement and the actual value. + This parameter does not apply to sensors without numerical reading." + ::= { outletSensorConfigurationEntry 8 } -outletSensorResolution OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The resolution: the minimum difference between any two measured values - The value of this OID variable should be scaled by - outletSensorDecimalDigits. For example, if the value is 1 and - outletSensorDecimalDigits is 2, then actual value is 0.01. - This parameter does not apply to sensors without numerical reading, - e.g. outlet state sensors." - ::= { outletSensorConfigurationEntry 9 } +outletSensorResolution OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The resolution: the minimum difference between any two measured values + The value of this OID variable should be scaled by + outletSensorDecimalDigits. For example, if the value is 1 and + outletSensorDecimalDigits is 2, then actual value is 0.01. + This parameter does not apply to sensors without numerical reading." + ::= { outletSensorConfigurationEntry 9 } -outletSensorTolerance OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS deprecated - DESCRIPTION - "The resolution: the difference between a sensor value and the actual value - The value of this OID variable should be scaled by - (outletSensorDecimalDigits + 1). For example, if the value is 50 and - outletSensorDecimalDigits is 2, then actual value is 0.05. - This parameter does not apply to sensors without numerical reading, - e.g. outlet state sensors." - ::= { outletSensorConfigurationEntry 10 } +outletSensorTolerance OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The tolerance: the maximum difference between measurement and the + actual value. The value of this OID variable should be scaled by + (outletSensorDecimalDigits + 1). For example, if the value is 50 and + outletSensorDecimalDigits is 2, then actual value is 0.05. + This parameter does not apply to sensors without numerical reading." + ::= { outletSensorConfigurationEntry 10 } -outletSensorMaximum OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The largest possible reading as an unsigned integer. - The value of this OID variable should be scaled by - outletSensorDecimalDigits. For example, if the value is 1 and - outletSensorDecimalDigits is 2, then actual value is 0.01. - The value is clamped if the scaled maximum exceeds 4294967295. It - is undefined for sensors which can have negative readings. - This parameter does not apply to sensors without numerical reading, - e.g. outlet state sensors." - ::= { outletSensorConfigurationEntry 11 } +outletSensorMaximum OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The largest possible reading as an unsigned integer. + The value of this OID variable should be scaled by + outletSensorDecimalDigits. For example, if the value is 1 and + outletSensorDecimalDigits is 2, then actual value is 0.01. + The value is clamped if the scaled maximum exceeds 4294967295. It + is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { outletSensorConfigurationEntry 11 } -outletSensorMinimum OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The smallest possible reading as an unsigned integer. - The value of this OID variable should be scaled by - outletSensorDecimalDigits. For example, if the value is 1 and - outletSensorDecimalDigits is 2, then actual value is 0.01. - The value is undefined for sensors which can have negative readings. - This parameter does not apply to sensors without numerical reading, - e.g. outlet state sensors." - ::= { outletSensorConfigurationEntry 12 } +outletSensorMinimum OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The smallest possible reading as an unsigned integer. + The value of this OID variable should be scaled by + outletSensorDecimalDigits. For example, if the value is 1 and + outletSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { outletSensorConfigurationEntry 12 } -outletSensorHysteresis OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The hysteresis used for deassertions - The value of this OID variable should be scaled by - outletSensorDecimalDigits. For example, if the value is 1 and - outletSensorDecimalDigits is 2, then actual value is 0.01. - This parameter does not apply to sensors without numerical reading, - e.g. outlet state sensors." - ::= { outletSensorConfigurationEntry 13 } +outletSensorHysteresis OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The hysteresis used when crossing a threshold towards the normal state. + The value of this OID variable should be scaled by + outletSensorDecimalDigits. For example, if the value is 1 and + outletSensorDecimalDigits is 2, then actual value is 0.01. + This parameter does not apply to sensors without numerical reading." + ::= { outletSensorConfigurationEntry 13 } -outletSensorStateChangeDelay OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The delay measured in samples before a state is asserted. - If the value is zero, then the state is asserted as soon as - it is detected; if it is non-zero, say n, then the assertion - condition must exist for n+1 consecutive samples before the corresponding - assertion event is reported. - This parameter does not apply to sensors without numerical reading, - e.g. outlet state sensors." - ::= { outletSensorConfigurationEntry 14 } +outletSensorStateChangeDelay OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The delay measured in samples before a state is asserted. + If the value is zero, then the state is asserted as soon as + it is detected; if it is non-zero, say n, then the assertion + condition must exist for n+1 consecutive samples before the + event is reported. + This parameter does not apply to sensors without numerical reading." + ::= { outletSensorConfigurationEntry 14 } -outletSensorLowerCriticalThreshold OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The lower critical threshold as an unsigned integer. - The value of this OID variable should be scaled by - outletSensorDecimalDigits. For example, if the value is 1 and - outletSensorDecimalDigits is 2, then actual value is 0.01. - The value is clamped if the scaled threshold exceeds 4294967295. It - is undefined for sensors which can have negative readings. - This parameter does not apply to sensors without numerical reading, - e.g. outlet state sensors." - ::= { outletSensorConfigurationEntry 21 } +outletSensorLowerCriticalThreshold OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The lower critical threshold as an unsigned integer. + The value of this OID variable should be scaled by + outletSensorDecimalDigits. For example, if the value is 1 and + outletSensorDecimalDigits is 2, then actual value is 0.01. + The value is clamped if the scaled threshold exceeds 4294967295. It + is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { outletSensorConfigurationEntry 21 } -outletSensorLowerWarningThreshold OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The lower warning threshold as an unsigned integer. - The value of this OID variable should be scaled by - outletSensorDecimalDigits. For example, if the value is 1 and - outletSensorDecimalDigits is 2, then actual value is 0.01. - The value is clamped if the scaled threshold exceeds 4294967295. It - is undefined for sensors which can have negative readings. - This parameter does not apply to sensors without numerical reading, - e.g. outlet state sensors." - ::= { outletSensorConfigurationEntry 22 } +outletSensorLowerWarningThreshold OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The lower warning threshold as an unsigned integer. + The value of this OID variable should be scaled by + outletSensorDecimalDigits. For example, if the value is 1 and + outletSensorDecimalDigits is 2, then actual value is 0.01. + The value is clamped if the scaled threshold exceeds 4294967295. It + is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { outletSensorConfigurationEntry 22 } -outletSensorUpperCriticalThreshold OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The upper critical threshold as an unsigned integer. - The value of this OID variable should be scaled by - outletSensorDecimalDigits. For example, if the value is 1 and - outletSensorDecimalDigits is 2, then actual value is 0.01. - The value is clamped if the scaled threshold exceeds 4294967295. It - is undefined for sensors which can have negative readings. - This parameter does not apply to sensors without numerical reading, - e.g. outlet state sensors." - ::= { outletSensorConfigurationEntry 23 } +outletSensorUpperCriticalThreshold OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The upper critical threshold as an unsigned integer. + The value of this OID variable should be scaled by + outletSensorDecimalDigits. For example, if the value is 1 and + outletSensorDecimalDigits is 2, then actual value is 0.01. + The value is clamped if the scaled threshold exceeds 4294967295. It + is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { outletSensorConfigurationEntry 23 } -outletSensorUpperWarningThreshold OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The upper warning threshold as an unsigned integer. - The value of this OID variable should be scaled by - outletSensorDecimalDigits. For example, if the value is 1 and - outletSensorDecimalDigits is 2, then actual value is 0.01. - The value is clamped if the scaled threshold exceeds 4294967295. It - is undefined for sensors which can have negative readings. - This parameter does not apply to sensors without numerical reading, - e.g. outlet state sensors." - ::= { outletSensorConfigurationEntry 24 } +outletSensorUpperWarningThreshold OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The upper warning threshold as an unsigned integer. + The value of this OID variable should be scaled by + outletSensorDecimalDigits. For example, if the value is 1 and + outletSensorDecimalDigits is 2, then actual value is 0.01. + The value is clamped if the scaled threshold exceeds 4294967295. It + is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { outletSensorConfigurationEntry 24 } -outletSensorEnabledThresholds OBJECT-TYPE - SYNTAX BITS{ - lowerCritical(0), - lowerWarning(1), - upperWarning(2), - upperCritical(3) - } - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "A bit string which indicates which thresholds are enabled. - This parameter does not apply to sensors without numerical reading, - e.g. outlet state sensors." - ::= { outletSensorConfigurationEntry 25 } +outletSensorEnabledThresholds OBJECT-TYPE + SYNTAX BITS { lowerCritical(0), + lowerWarning(1), + upperWarning(2), + upperCritical(3) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "A bit string indicating which thresholds are enabled. + This parameter does not apply to sensors without numerical reading." + ::= { outletSensorConfigurationEntry 25 } -outletSensorSignedMaximum OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The largest possible reading as a signed integer. - The value of this OID variable should be scaled by - outletSensorDecimalDigits. For example, if the value is 1 and - outletSensorDecimalDigits is 2, then actual value is 0.01. - The value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647). - This parameter does not apply to sensors without numerical reading, - e.g. outlet state sensors." - ::= { outletSensorConfigurationEntry 26 } +outletSensorSignedMaximum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The largest possible reading as a signed integer. + The value of this OID variable should be scaled by + outletSensorDecimalDigits. For example, if the value is 1 and + outletSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { outletSensorConfigurationEntry 26 } -outletSensorSignedMinimum OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The smallest possible reading as a signed integer. - The value of this OID variable should be scaled by - outletSensorDecimalDigits. For example, if the value is 1 and - outletSensorDecimalDigits is 2, then actual value is 0.01. - This value determines whether to use the signed or unsigned threshold - and value columns: If the minimum is below zero the sensor can have - negative readings and the signed columns should be used. - This parameter does not apply to sensors without numerical reading, - e.g. outlet state sensors." - ::= { outletSensorConfigurationEntry 27 } +outletSensorSignedMinimum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The smallest possible reading as a signed integer. + The value of this OID variable should be scaled by + outletSensorDecimalDigits. For example, if the value is 1 and + outletSensorDecimalDigits is 2, then actual value is 0.01. + This value determines whether to use the signed or unsigned threshold + and value columns: If the minimum is below zero the sensor can have + negative readings and the signed columns should be used. + This parameter does not apply to sensors without numerical reading." + ::= { outletSensorConfigurationEntry 27 } outletSensorSignedLowerCriticalThreshold OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The lower critical threshold as a signed integer. - The value of this OID variable should be scaled by - outletSensorDecimalDigits. For example, if the value is 1 and - outletSensorDecimalDigits is 2, then actual value is 0.01. - The value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647). - This parameter does not apply to sensors without numerical reading, - e.g. outlet state sensors." - ::= { outletSensorConfigurationEntry 28 } + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The lower critical threshold as a signed integer. + The value of this OID variable should be scaled by + outletSensorDecimalDigits. For example, if the value is 1 and + outletSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { outletSensorConfigurationEntry 28 } outletSensorSignedLowerWarningThreshold OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The lower warning threshold as a signed integer. - The value of this OID variable should be scaled by - outletSensorDecimalDigits. For example, if the value is 1 and - outletSensorDecimalDigits is 2, then actual value is 0.01. - The value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647). - This parameter does not apply to sensors without numerical reading, - e.g. outlet state sensors." - ::= { outletSensorConfigurationEntry 29 } + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The lower warning threshold as a signed integer. + The value of this OID variable should be scaled by + outletSensorDecimalDigits. For example, if the value is 1 and + outletSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { outletSensorConfigurationEntry 29 } outletSensorSignedUpperCriticalThreshold OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The upper critical threshold as a signed integer. - The value of this OID variable should be scaled by - outletSensorDecimalDigits. For example, if the value is 1 and - outletSensorDecimalDigits is 2, then actual value is 0.01. - The value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647). - This parameter does not apply to sensors without numerical reading, - e.g. outlet state sensors." - ::= { outletSensorConfigurationEntry 30 } + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The upper critical threshold as a signed integer. + The value of this OID variable should be scaled by + outletSensorDecimalDigits. For example, if the value is 1 and + outletSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { outletSensorConfigurationEntry 30 } outletSensorSignedUpperWarningThreshold OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The upper warning threshold as a signed integer. - The value of this OID variable should be scaled by - outletSensorDecimalDigits. For example, if the value is 1 and - outletSensorDecimalDigits is 2, then actual value is 0.01. - The value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647). - This parameter does not apply to sensors without numerical reading, - e.g. outlet state sensors." - ::= { outletSensorConfigurationEntry 31 } + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The upper warning threshold as a signed integer. + The value of this OID variable should be scaled by + outletSensorDecimalDigits. For example, if the value is 1 and + outletSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { outletSensorConfigurationEntry 31 } +-- outletPoleSensorConfigurationTable: information and settings for outlet pole sensors +outletPoleSensorConfigurationTable OBJECT-TYPE + SYNTAX SEQUENCE OF OutletPoleSensorConfigurationEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of outlet pole sensor configuration entries." + ::= { outlets 6 } --- The outletPoleSensorConfiguration table contains information on the PDU's outlet pole Sensors. +outletPoleSensorConfigurationEntry OBJECT-TYPE + SYNTAX OutletPoleSensorConfigurationEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing objects for configuring an outlet pole sensor." + INDEX { pduId, outletId, outletPoleIndex, sensorType } + ::= { outletPoleSensorConfigurationTable 1 } +OutletPoleSensorConfigurationEntryStruct ::= SEQUENCE { + outletPoleIndex Integer32, + outletPoleSensorLogAvailable TruthValue, + outletPoleSensorUnits SensorUnitsEnumeration, + outletPoleSensorDecimalDigits Unsigned32, + outletPoleSensorAccuracy HundredthsOfAPercentage, + outletPoleSensorResolution Unsigned32, + outletPoleSensorTolerance Unsigned32, + outletPoleSensorMaximum Unsigned32, + outletPoleSensorMinimum Unsigned32, + outletPoleSensorHysteresis Unsigned32, + outletPoleSensorStateChangeDelay Unsigned32, + outletPoleSensorLowerCriticalThreshold Unsigned32, + outletPoleSensorLowerWarningThreshold Unsigned32, + outletPoleSensorUpperCriticalThreshold Unsigned32, + outletPoleSensorUpperWarningThreshold Unsigned32, + outletPoleSensorEnabledThresholds BITS, + outletPoleSensorSignedMaximum Integer32, + outletPoleSensorSignedMinimum Integer32, + outletPoleSensorSignedLowerCriticalThreshold Integer32, + outletPoleSensorSignedLowerWarningThreshold Integer32, + outletPoleSensorSignedUpperCriticalThreshold Integer32, + outletPoleSensorSignedUpperWarningThreshold Integer32 + } -outletPoleSensorConfigurationTable OBJECT-TYPE - SYNTAX SEQUENCE OF OutletPoleSensorConfigurationEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A list of outlet pole sensor configuration entries. The number of - entries is given by the value of outletPoleCount." - ::= { outlets 6 } +outletPoleIndex OBJECT-TYPE + SYNTAX Integer32(1..256) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A unique value for each outlet pole. Its value + ranges between 1 and the value of outletPoleCount." + ::= { outletPoleSensorConfigurationEntry 1 } -outletPoleSensorConfigurationEntry OBJECT-TYPE - SYNTAX OutletPoleSensorConfigurationEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "An entry containing objects - for configuring an outlet pole sensor." - INDEX { pduId, outletId,outletPoleIndex,sensorType } - ::= { outletPoleSensorConfigurationTable 1 } +outletPoleSensorLogAvailable OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is data logging enabled for the sensor?" + ::= { outletPoleSensorConfigurationEntry 4 } -OutletPoleSensorConfigurationEntryStruct ::= SEQUENCE { outletPoleIndex Integer32, - outletPoleSensorLogAvailable TruthValue, - outletPoleSensorUnits SensorUnitsEnumeration, - outletPoleSensorDecimalDigits Unsigned32, - outletPoleSensorAccuracy HundredthsOfAPercentage, - outletPoleSensorResolution Unsigned32, - outletPoleSensorTolerance Unsigned32, - outletPoleSensorMaximum Unsigned32, - outletPoleSensorMinimum Unsigned32, - outletPoleSensorHysteresis Unsigned32, - outletPoleSensorStateChangeDelay Unsigned32, - outletPoleSensorLowerCriticalThreshold Unsigned32, - outletPoleSensorLowerWarningThreshold Unsigned32, - outletPoleSensorUpperCriticalThreshold Unsigned32, - outletPoleSensorUpperWarningThreshold Unsigned32, - outletPoleSensorEnabledThresholds BITS, - outletPoleSensorSignedMaximum Integer32, - outletPoleSensorSignedMinimum Integer32, - outletPoleSensorSignedLowerCriticalThreshold Integer32, - outletPoleSensorSignedLowerWarningThreshold Integer32, - outletPoleSensorSignedUpperCriticalThreshold Integer32, - outletPoleSensorSignedUpperWarningThreshold Integer32 - } +outletPoleSensorUnits OBJECT-TYPE + SYNTAX SensorUnitsEnumeration + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The unit in which the sensor reading is reported. + This parameter does not apply to sensors without numerical reading." + ::= { outletPoleSensorConfigurationEntry 6 } -outletPoleIndex OBJECT-TYPE - SYNTAX Integer32(1..256) - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A unique value for each outlet Pole. Its value - ranges between 1 and the value of outletPoleCount." - ::= { outletPoleSensorConfigurationEntry 1 } +outletPoleSensorDecimalDigits OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of digits displayed to the right of the decimal point. + This parameter does not apply to sensors without numerical reading." + ::= { outletPoleSensorConfigurationEntry 7 } -outletPoleSensorLogAvailable OBJECT-TYPE - SYNTAX TruthValue - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "Is logging enabled for the sensor?" - ::= { outletPoleSensorConfigurationEntry 4 } +outletPoleSensorAccuracy OBJECT-TYPE + SYNTAX HundredthsOfAPercentage + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The accuracy: the maximum relative difference (in percent) between + measurement and the actual value. + This parameter does not apply to sensors without numerical reading." + ::= { outletPoleSensorConfigurationEntry 8 } -outletPoleSensorUnits OBJECT-TYPE - SYNTAX SensorUnitsEnumeration - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The base units. - This parameter does not apply to sensors without numerical reading." - ::= { outletPoleSensorConfigurationEntry 6 } +outletPoleSensorResolution OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The resolution: the minimum difference between any two measured values + The value of this OID variable should be scaled by + outletPoleSensorDecimalDigits. For example, if the value is 1 and + outletPoleSensorDecimalDigits is 2, then actual value is 0.01. + This parameter does not apply to sensors without numerical reading." + ::= { outletPoleSensorConfigurationEntry 9 } -outletPoleSensorDecimalDigits OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The number of digits displayed to the right of the decimal point. - This parameter does not apply to sensors without numerical reading." - ::= { outletPoleSensorConfigurationEntry 7 } +outletPoleSensorTolerance OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The tolerance: the maximum difference between measurement and the + actual value. The value of this OID variable should be scaled by + (outletPoleSensorDecimalDigits + 1). For example, if the value is 50 and + outletPoleSensorDecimalDigits is 2, then actual value is 0.05. + This parameter does not apply to sensors without numerical reading." + ::= { outletPoleSensorConfigurationEntry 10 } -outletPoleSensorAccuracy OBJECT-TYPE - SYNTAX HundredthsOfAPercentage - MAX-ACCESS read-only - STATUS deprecated - DESCRIPTION - "The accuracy: how close (in percent) the measurement is to the actual value. - This parameter does not apply to sensors without numerical reading." - ::= { outletPoleSensorConfigurationEntry 8 } +outletPoleSensorMaximum OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The largest possible reading as an unsigned integer. + The value of this OID variable should be scaled by + outletPoleSensorDecimalDigits. For example, if the value is 1 and + outletPoleSensorDecimalDigits is 2, then actual value is 0.01. + The value is clamped if the scaled maximum exceeds 4294967295. It + is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { outletPoleSensorConfigurationEntry 11 } +outletPoleSensorMinimum OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The smallest possible reading as an unsigned integer. + The value of this OID variable should be scaled by + outletPoleSensorDecimalDigits. For example, if the value is 1 and + outletPoleSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { outletPoleSensorConfigurationEntry 12 } -outletPoleSensorResolution OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The resolution: the minimum difference between any two measured values - The value of this OID variable should be scaled by - outletPoleSensorDecimalDigits. For example, if the value is 50 and - outletPoleSensorDecimalDigits is 2, then actual value is 0.05. - This parameter does not apply to sensors without numerical reading." - ::= { outletPoleSensorConfigurationEntry 9 } +outletPoleSensorHysteresis OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The hysteresis used when crossing a threshold towards the normal state. + The value of this OID variable should be scaled by + outletPoleSensorDecimalDigits. For example, if the value is 1 and + outletPoleSensorDecimalDigits is 2, then actual value is 0.01. + This parameter does not apply to sensors without numerical reading." + ::= { outletPoleSensorConfigurationEntry 13 } -outletPoleSensorTolerance OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS deprecated - DESCRIPTION - "The resolution: the difference between a sensor value and the actual value - The value of this OID variable should be scaled by - (outletPoleSensorDecimalDigits + 1). For example, if the value is 50 and - outletPoleSensorDecimalDigits is 2, then actual value is 0.05. - This parameter does not apply to sensors without numerical reading." - ::= { outletPoleSensorConfigurationEntry 10 } - -outletPoleSensorMaximum OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The largest possible reading as an unsigned integer. - The value of this OID variable should be scaled by - outletPoleSensorDecimalDigits. For example, if the value is 1 and - outletPoleSensorDecimalDigits is 2, then actual value is 0.01. - The value is clamped if the scaled maximum exceeds 4294967295. It - is undefined for sensors which can have negative readings. - This parameter does not apply to sensors without numerical reading." - ::= { outletPoleSensorConfigurationEntry 11 } - -outletPoleSensorMinimum OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The smallest possible reading as an unsigned integer. - The value of this OID variable should be scaled by - outletPoleSensorDecimalDigits. For example, if the value is 1 and - outletPoleSensorDecimalDigits is 2, then actual value is 0.01. - The value is undefined for sensors which can have negative readings. - This parameter does not apply to sensors without numerical reading." - ::= { outletPoleSensorConfigurationEntry 12 } - -outletPoleSensorHysteresis OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The hysteresis used for deassertions - The value of this OID variable should be scaled by - outletPoleSensorDecimalDigits. For example, if the value is 1 and - outletPoleSensorDecimalDigits is 2, then actual value is 0.01. - This parameter does not apply to sensors without numerical reading." - ::= { outletPoleSensorConfigurationEntry 13 } - -outletPoleSensorStateChangeDelay OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The delay measured in samples before a state is asserted. - If the value is zero, then the state is asserted as soon as - it is detected; if it is non-zero, say n, then the assertion - condition must exist for n+1 consecutive samples before the corresponding - assertion event is reported. - This parameter does not apply to sensors without numerical reading." - ::= { outletPoleSensorConfigurationEntry 14 } +outletPoleSensorStateChangeDelay OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The delay measured in samples before a state is asserted. + If the value is zero, then the state is asserted as soon as + it is detected; if it is non-zero, say n, then the assertion + condition must exist for n+1 consecutive samples before the + event is reported. + This parameter does not apply to sensors without numerical reading." + ::= { outletPoleSensorConfigurationEntry 14 } outletPoleSensorLowerCriticalThreshold OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The lower critical threshold as an unsigned integer. - The value of this OID variable should be scaled by - outletPoleSensorDecimalDigits. For example, if the value is 1 and - outletPoleSensorDecimalDigits is 2, then actual value is 0.01. - The value is clamped if the scaled threshold exceeds 4294967295. It - is undefined for sensors which can have negative readings. - This parameter does not apply to sensors without numerical reading." - ::= { outletPoleSensorConfigurationEntry 21 } + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The lower critical threshold as an unsigned integer. + The value of this OID variable should be scaled by + outletPoleSensorDecimalDigits. For example, if the value is 1 and + outletPoleSensorDecimalDigits is 2, then actual value is 0.01. + The value is clamped if the scaled threshold exceeds 4294967295. It + is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { outletPoleSensorConfigurationEntry 21 } outletPoleSensorLowerWarningThreshold OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The lower warning threshold as an unsigned integer. - The value of this OID variable should be scaled by - outletPoleSensorDecimalDigits. For example, if the value is 1 and - outletPoleSensorDecimalDigits is 2, then actual value is 0.01. - The value is clamped if the scaled threshold exceeds 4294967295. It - is undefined for sensors which can have negative readings. - This parameter does not apply to sensors without numerical reading." - ::= { outletPoleSensorConfigurationEntry 22 } + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The lower warning threshold as an unsigned integer. + The value of this OID variable should be scaled by + outletPoleSensorDecimalDigits. For example, if the value is 1 and + outletPoleSensorDecimalDigits is 2, then actual value is 0.01. + The value is clamped if the scaled threshold exceeds 4294967295. It + is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { outletPoleSensorConfigurationEntry 22 } outletPoleSensorUpperCriticalThreshold OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The upper critical threshold as an unsigned integer. - The value of this OID variable should be scaled by - outletPoleSensorDecimalDigits. For example, if the value is 1 and - outletPoleSensorDecimalDigits is 2, then actual value is 0.01. - The value is clamped if the scaled threshold exceeds 4294967295. It - is undefined for sensors which can have negative readings. - This parameter does not apply to sensors without numerical reading." - ::= { outletPoleSensorConfigurationEntry 23 } + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The upper critical threshold as an unsigned integer. + The value of this OID variable should be scaled by + outletPoleSensorDecimalDigits. For example, if the value is 1 and + outletPoleSensorDecimalDigits is 2, then actual value is 0.01. + The value is clamped if the scaled threshold exceeds 4294967295. It + is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { outletPoleSensorConfigurationEntry 23 } outletPoleSensorUpperWarningThreshold OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The upper warning threshold as an unsigned integer. - The value of this OID variable should be scaled by - outletPoleSensorDecimalDigits. For example, if the value is 1 and - outletPoleSensorDecimalDigits is 2, then actual value is 0.01. - The value is clamped if the scaled threshold exceeds 4294967295. It - is undefined for sensors which can have negative readings. - This parameter does not apply to sensors without numerical reading." - ::= { outletPoleSensorConfigurationEntry 24 } + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The upper warning threshold as an unsigned integer. + The value of this OID variable should be scaled by + outletPoleSensorDecimalDigits. For example, if the value is 1 and + outletPoleSensorDecimalDigits is 2, then actual value is 0.01. + The value is clamped if the scaled threshold exceeds 4294967295. It + is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { outletPoleSensorConfigurationEntry 24 } -outletPoleSensorEnabledThresholds OBJECT-TYPE - SYNTAX BITS{ - lowerCritical(0), - lowerWarning(1), - upperWarning(2), - upperCritical(3) - } - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "A bit string which indicates which thresholds are enabled. - This parameter does not apply to sensors without numerical reading." - ::= { outletPoleSensorConfigurationEntry 25 } +outletPoleSensorEnabledThresholds OBJECT-TYPE + SYNTAX BITS { lowerCritical(0), + lowerWarning(1), + upperWarning(2), + upperCritical(3) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "A bit string indicating which thresholds are enabled. + This parameter does not apply to sensors without numerical reading." + ::= { outletPoleSensorConfigurationEntry 25 } -outletPoleSensorSignedMaximum OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The largest possible reading as a signed integer. - The value of this OID variable should be scaled by - outletPoleSensorDecimalDigits. For example, if the value is 1 and - outletPoleSensorDecimalDigits is 2, then actual value is 0.01. - The value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647). - This parameter does not apply to sensors without numerical reading." - ::= { outletPoleSensorConfigurationEntry 26 } +outletPoleSensorSignedMaximum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The largest possible reading as a signed integer. + The value of this OID variable should be scaled by + outletPoleSensorDecimalDigits. For example, if the value is 1 and + outletPoleSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { outletPoleSensorConfigurationEntry 26 } -outletPoleSensorSignedMinimum OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The smallest possible reading as a signed integer. - The value of this OID variable should be scaled by - outletPoleSensorDecimalDigits. For example, if the value is 1 and - outletPoleSensorDecimalDigits is 2, then actual value is 0.01. - This value determines whether to use the signed or unsigned threshold - and value columns: If the minimum is below zero the sensor can have - negative readings and the signed columns should be used. - This parameter does not apply to sensors without numerical reading." - ::= { outletPoleSensorConfigurationEntry 27 } +outletPoleSensorSignedMinimum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The smallest possible reading as a signed integer. + The value of this OID variable should be scaled by + outletPoleSensorDecimalDigits. For example, if the value is 1 and + outletPoleSensorDecimalDigits is 2, then actual value is 0.01. + This value determines whether to use the signed or unsigned threshold + and value columns: If the minimum is below zero the sensor can have + negative readings and the signed columns should be used. + This parameter does not apply to sensors without numerical reading." + ::= { outletPoleSensorConfigurationEntry 27 } outletPoleSensorSignedLowerCriticalThreshold OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The lower critical threshold as a signed integer. - The value of this OID variable should be scaled by - outletPoleSensorDecimalDigits. For example, if the value is 1 and - outletPoleSensorDecimalDigits is 2, then actual value is 0.01. - The value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647). - This parameter does not apply to sensors without numerical reading." - ::= { outletPoleSensorConfigurationEntry 28 } + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The lower critical threshold as a signed integer. + The value of this OID variable should be scaled by + outletPoleSensorDecimalDigits. For example, if the value is 1 and + outletPoleSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { outletPoleSensorConfigurationEntry 28 } outletPoleSensorSignedLowerWarningThreshold OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The lower warning threshold as a signed integer. - The value of this OID variable should be scaled by - outletPoleSensorDecimalDigits. For example, if the value is 1 and - outletPoleSensorDecimalDigits is 2, then actual value is 0.01. - The value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647). - This parameter does not apply to sensors without numerical reading." - ::= { outletPoleSensorConfigurationEntry 29 } + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The lower warning threshold as a signed integer. + The value of this OID variable should be scaled by + outletPoleSensorDecimalDigits. For example, if the value is 1 and + outletPoleSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { outletPoleSensorConfigurationEntry 29 } outletPoleSensorSignedUpperCriticalThreshold OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The upper critical threshold as a signed integer. - The value of this OID variable should be scaled by - outletPoleSensorDecimalDigits. For example, if the value is 1 and - outletPoleSensorDecimalDigits is 2, then actual value is 0.01. - The value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647). - This parameter does not apply to sensors without numerical reading." - ::= { outletPoleSensorConfigurationEntry 30 } + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The upper critical threshold as a signed integer. + The value of this OID variable should be scaled by + outletPoleSensorDecimalDigits. For example, if the value is 1 and + outletPoleSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { outletPoleSensorConfigurationEntry 30 } outletPoleSensorSignedUpperWarningThreshold OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The upper warning threshold as a signed integer. - The value of this OID variable should be scaled by - outletPoleSensorDecimalDigits. For example, if the value is 1 and - outletPoleSensorDecimalDigits is 2, then actual value is 0.01. - The value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647). - This parameter does not apply to sensors without numerical reading." - ::= { outletPoleSensorConfigurationEntry 31 } + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The upper warning threshold as a signed integer. + The value of this OID variable should be scaled by + outletPoleSensorDecimalDigits. For example, if the value is 1 and + outletPoleSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { outletPoleSensorConfigurationEntry 31 } +-- externalSensorConfigurationTable: external sensor information and settings +externalSensorConfigurationTable OBJECT-TYPE + SYNTAX SEQUENCE OF ExternalSensorConfigurationEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of external sensor configuration entries. The number of + entries is given by the value of externalSensorCount for the PDU." + ::= { externalSensors 3 } --- the externalSensorConfiguration table +externalSensorConfigurationEntry OBJECT-TYPE + SYNTAX ExternalSensorConfigurationEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing parameters for an external sensor." + INDEX { pduId, sensorID } + ::= { externalSensorConfigurationTable 1 } --- The externalSensorConfiguration table contains information on the PDU's external Sensors. +ExternalSensorConfigurationEntryStruct ::= SEQUENCE { + sensorID Integer32, + externalSensorType SensorTypeEnumeration, + externalSensorSerialNumber DisplayString, + externalSensorName DisplayString, + externalSensorDescription DisplayString, + externalSensorXCoordinate DisplayString, + externalSensorYCoordinate DisplayString, + externalSensorZCoordinate DisplayString, + externalSensorChannelNumber Integer32, + externalOnOffSensorSubtype SensorTypeEnumeration, + externalSensorLogAvailable TruthValue, + externalSensorUnits SensorUnitsEnumeration, + externalSensorDecimalDigits Unsigned32, + externalSensorAccuracy HundredthsOfAPercentage, + externalSensorResolution Unsigned32, + externalSensorTolerance Unsigned32, + externalSensorMaximum Integer32, + externalSensorMinimum Integer32, + externalSensorHysteresis Unsigned32, + externalSensorStateChangeDelay Unsigned32, + externalSensorLowerCriticalThreshold Integer32, + externalSensorLowerWarningThreshold Integer32, + externalSensorUpperCriticalThreshold Integer32, + externalSensorUpperWarningThreshold Integer32, + externalSensorEnabledThresholds BITS, + externalSensorIsActuator TruthValue, + externalSensorPosition DisplayString, + externalSensorUseDefaultThresholds TruthValue, + externalSensorAlarmedToNormalDelay Integer32 + } +sensorID OBJECT-TYPE + SYNTAX Integer32(1..256) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A unique value for each sensor. Its value + ranges between 1 and the value of externalSensorCount." + ::= { externalSensorConfigurationEntry 1 } +externalSensorType OBJECT-TYPE + SYNTAX SensorTypeEnumeration + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The type of sensor." + ::= { externalSensorConfigurationEntry 2 } -externalSensorConfigurationTable OBJECT-TYPE - SYNTAX SEQUENCE OF ExternalSensorConfigurationEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A list of externalSensor configuration entries. The number of - entries is given by the value of externalSensorCount for the PDU." - ::= { externalSensors 3 } +externalSensorSerialNumber OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The sensor serial number." + ::= { externalSensorConfigurationEntry 3 } -externalSensorConfigurationEntry OBJECT-TYPE - SYNTAX ExternalSensorConfigurationEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "An entry containing parameters for an external sensor." - INDEX { pduId, sensorID } - ::= { externalSensorConfigurationTable 1 } +externalSensorName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The user-defined name." + ::= { externalSensorConfigurationEntry 4 } -ExternalSensorConfigurationEntryStruct ::= SEQUENCE {sensorID Integer32, - externalSensorType SensorTypeEnumeration, - externalSensorSerialNumber DisplayString, - externalSensorName DisplayString, - externalSensorDescription DisplayString, - externalSensorXCoordinate DisplayString, - externalSensorYCoordinate DisplayString, - externalSensorZCoordinate DisplayString, - externalSensorChannelNumber Integer32, - externalOnOffSensorSubtype SensorTypeEnumeration, - externalSensorLogAvailable TruthValue, - externalSensorUnits SensorUnitsEnumeration, - externalSensorDecimalDigits Unsigned32, - externalSensorAccuracy HundredthsOfAPercentage, - externalSensorResolution Unsigned32, - externalSensorTolerance Unsigned32, - externalSensorMaximum Integer32, - externalSensorMinimum Integer32, - externalSensorHysteresis Unsigned32, - externalSensorStateChangeDelay Unsigned32, - externalSensorLowerCriticalThreshold Integer32, - externalSensorLowerWarningThreshold Integer32, - externalSensorUpperCriticalThreshold Integer32, - externalSensorUpperWarningThreshold Integer32, - externalSensorEnabledThresholds BITS, - externalSensorIsActuator TruthValue, - externalSensorPosition DisplayString, - externalSensorUseDefaultThresholds TruthValue, - externalSensorAlarmedToNormalDelay Integer32 - } +externalSensorDescription OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The user-defined description." + ::= { externalSensorConfigurationEntry 5 } -sensorID OBJECT-TYPE - SYNTAX Integer32(1..256) - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A unique value for each sensor. Its value - ranges between 1 and the value of externalSensorCount." - ::= { externalSensorConfigurationEntry 1 } +externalSensorXCoordinate OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The X coordinate." + ::= { externalSensorConfigurationEntry 6 } +externalSensorYCoordinate OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The Y coordinate." + ::= { externalSensorConfigurationEntry 7 } -externalSensorType OBJECT-TYPE - SYNTAX SensorTypeEnumeration - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The type of sensor." - ::= { externalSensorConfigurationEntry 2 } +externalSensorZCoordinate OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The Z coordinate. The value must be a number if + externalSensorsZCoordinateUnits is rackUnits." + ::= { externalSensorConfigurationEntry 8 } +externalSensorChannelNumber OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The channel number. + This applies only to contact sensors, -1 for other sensors." + ::= { externalSensorConfigurationEntry 9 } +externalOnOffSensorSubtype OBJECT-TYPE + SYNTAX SensorTypeEnumeration + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The subtype of the binary sensor." + ::= { externalSensorConfigurationEntry 10 } +externalSensorLogAvailable OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is data logging enabled for this sensor?" + ::= { externalSensorConfigurationEntry 14 } +externalSensorUnits OBJECT-TYPE + SYNTAX SensorUnitsEnumeration + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The unit in which the sensor reading is reported. + This parameter does not apply to sensors without numerical reading." + ::= { externalSensorConfigurationEntry 16 } -externalSensorSerialNumber OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The sensor serial number." - ::= { externalSensorConfigurationEntry 3 } +externalSensorDecimalDigits OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of digits displayed to the right of the decimal point. + This parameter does not apply to sensors without numerical reading." + ::= { externalSensorConfigurationEntry 17 } -externalSensorName OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The user-defined name." - ::= { externalSensorConfigurationEntry 4 } +externalSensorAccuracy OBJECT-TYPE + SYNTAX HundredthsOfAPercentage + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The accuracy: the maximum relative difference (in percent) between + measurement and the actual value. + This parameter does not apply to sensors without numerical reading." + ::= { externalSensorConfigurationEntry 18 } -externalSensorDescription OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The user-defined description." - ::= { externalSensorConfigurationEntry 5 } +externalSensorResolution OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The resolution: the minimum difference between any two measured values + The value of this OID variable should be scaled by + externalSensorDecimalDigits. For example, if the value is 1 and + externalSensorDecimalDigits is 2, then actual value is 0.01. + This parameter does not apply to sensors without numerical reading." + ::= { externalSensorConfigurationEntry 19 } -externalSensorXCoordinate OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The X coordinate." - ::= { externalSensorConfigurationEntry 6 } +externalSensorTolerance OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The tolerance: the maximum difference between measurement and the + actual value. The value of this OID variable should be scaled by + (externalSensorDecimalDigits + 1). For example, if the value is 50 and + externalSensorDecimalDigits is 2, then actual value is 0.05. + This parameter does not apply to sensors without numerical reading." + ::= { externalSensorConfigurationEntry 20 } -externalSensorYCoordinate OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The Y coordinate." - ::= { externalSensorConfigurationEntry 7 } +externalSensorMaximum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The largest possible value + The value of this OID variable should be scaled by + externalSensorDecimalDigits. For example, if the value is 1 and + externalSensorDecimalDigits is 2, then actual value is 0.01. + This parameter does not apply to sensors without numerical reading." + ::= { externalSensorConfigurationEntry 21 } -externalSensorZCoordinate OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The Z coordinate." - ::= { externalSensorConfigurationEntry 8 } +externalSensorMinimum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The smallest possible value + The value of this OID variable should be scaled by + externalSensorDecimalDigits. For example, if the value is 1 and + externalSensorDecimalDigits is 2, then actual value is 0.01. + This parameter does not apply to sensors without numerical reading." + ::= { externalSensorConfigurationEntry 22 } +externalSensorHysteresis OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The hysteresis used when crossing a threshold towards the normal state. + The value of this OID variable should be scaled by + externalSensorDecimalDigits. For example, if the value is 1 and + externalSensorDecimalDigits is 2, then actual value is 0.01. + This parameter does not apply to sensors without numerical reading." + ::= { externalSensorConfigurationEntry 23 } -externalSensorChannelNumber OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The channel number, applies only to contact sensors; - -1 for other sensors" - ::= { externalSensorConfigurationEntry 9 } +externalSensorStateChangeDelay OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The delay measured in samples before a state is asserted. + If the value is zero, then the state is asserted as soon as + it is detected; if it is non-zero, say n, then the assertion + condition must exist for n+1 consecutive samples before the + event is reported. + This parameter does not apply to sensors without numerical reading." + ::= { externalSensorConfigurationEntry 24 } -externalOnOffSensorSubtype OBJECT-TYPE - SYNTAX SensorTypeEnumeration - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The subtype of the binary sensor" - ::= { externalSensorConfigurationEntry 10 } +externalSensorLowerCriticalThreshold OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The lower critical threshold + The value of this OID variable should be scaled by + externalSensorDecimalDigits. For example, if the value is 1 and + externalSensorDecimalDigits is 2, then actual value is 0.01. + This parameter does not apply to sensors without numerical reading." + ::= { externalSensorConfigurationEntry 31 } +externalSensorLowerWarningThreshold OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The lower warning threshold + The value of this OID variable should be scaled by + externalSensorDecimalDigits. For example, if the value is 1 and + externalSensorDecimalDigits is 2, then actual value is 0.01. + This parameter does not apply to sensors without numerical reading." + ::= { externalSensorConfigurationEntry 32 } +externalSensorUpperCriticalThreshold OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The upper critical threshold + The value of this OID variable should be scaled by + externalSensorDecimalDigits. For example, if the value is 1 and + externalSensorDecimalDigits is 2, then actual value is 0.01. + This parameter does not apply to sensors without numerical reading." + ::= { externalSensorConfigurationEntry 33 } +externalSensorUpperWarningThreshold OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The upper warning threshold + The value of this OID variable should be scaled by + externalSensorDecimalDigits. For example, if the value is 1 and + externalSensorDecimalDigits is 2, then actual value is 0.01. + This parameter does not apply to sensors without numerical reading." + ::= { externalSensorConfigurationEntry 34 } -externalSensorLogAvailable OBJECT-TYPE - SYNTAX TruthValue - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "Is logging available for this sensor?" - ::= { externalSensorConfigurationEntry 14 } +externalSensorEnabledThresholds OBJECT-TYPE + SYNTAX BITS { lowerCritical(0), + lowerWarning(1), + upperWarning(2), + upperCritical(3) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "A bit string indicating which thresholds are enabled. + This parameter does not apply to sensors without numerical reading." + ::= { externalSensorConfigurationEntry 35} -externalSensorUnits OBJECT-TYPE - SYNTAX SensorUnitsEnumeration - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The base units - This parameter does not apply - to onOff, trip, vibration, waterDetection, - smokeDetection sensors." - ::= { externalSensorConfigurationEntry 16 } +externalSensorIsActuator OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Indicates whether the sensor is an actuator." + ::= { externalSensorConfigurationEntry 36 } -externalSensorDecimalDigits OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The number of digits displayed to the right of the decimal point - This parameter does not apply - to onOff, trip, vibration, waterDetection, - smokeDetection sensors." - ::= { externalSensorConfigurationEntry 17 } +externalSensorPosition OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The position of the sensor in the bus topology. + The format is a semicolon separated list of Keyword:value pairs. + Keyword can be one of the following: + ONBOARD, DEVICE-1WIREPORT, HUBPORT, CHAIN-POSITION + Examples: + 1) Onboard sensor + ONBOARD:CC1 + 2) Old sensor connected to device 1-wire port + DEVICE-1WIREPORT:2 + 3) New-style sensor connected to device 1-wire port + DEVICE-1WIREPORT:2;CHAIN-POSITION:3 + 4) New-style sensor connected to hub port 3 + DEVICE-1WIREPORT:2;CHAIN-POSITION:1;HUBPORT:3;CHAIN-POSITION:1 + 5) Old-style sensor connected to end of new-style sensor chain + DEVICE-1WIREPORT:2;" + ::= { externalSensorConfigurationEntry 37 } - - -externalSensorAccuracy OBJECT-TYPE - SYNTAX HundredthsOfAPercentage - MAX-ACCESS read-only - STATUS deprecated - DESCRIPTION - "The accuracy: how close (in percent) the measurement is to the actual value - This parameter does not apply - to onOff, trip, vibration, waterDetection, - smokeDetection sensors." - ::= { externalSensorConfigurationEntry 18 } - - -externalSensorResolution OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The resolution: the minimum difference between any two measured values - The value of this OID variable should be scaled by - externalSensorDecimalDigits. For example, if the value is 1 and - externalSensorDecimalDigits is 2, then actual value is 0.01. - This parameter does not apply - to onOff, trip, vibration, waterDetection, - smokeDetection sensors." - ::= { externalSensorConfigurationEntry 19 } - -externalSensorTolerance OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS deprecated - DESCRIPTION - "The resolution: the difference between a sensor value and the actual value - The value of this OID variable should be scaled by - (externalSensorDecimalDigits + 1). For example, if the value is 50 and - externalSensorDecimalDigits is 2, then actual value is 0.05. - This parameter does not apply - to onOff, trip, vibration, waterDetection, - smokeDetection sensors." - ::= { externalSensorConfigurationEntry 20 } - -externalSensorMaximum OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The largest possible value - The value of this OID variable should be scaled by - externalSensorDecimalDigits. For example, if the value is 1 and - externalSensorDecimalDigits is 2, then actual value is 0.01. - This parameter does not apply - to onOff, trip, vibration, waterDetection, - smokeDetection sensors." - ::= { externalSensorConfigurationEntry 21 } - -externalSensorMinimum OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The smallest possible value - The value of this OID variable should be scaled by - externalSensorDecimalDigits. For example, if the value is 1 and - externalSensorDecimalDigits is 2, then actual value is 0.01. - This parameter does not apply - to onOff, trip, vibration, waterDetection, - smokeDetection sensors." - ::= { externalSensorConfigurationEntry 22 } - - - -externalSensorHysteresis OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The hysteresis used for deassertions - The value of this OID variable should be scaled by - externalSensorDecimalDigits. For example, if the value is 1 and - externalSensorDecimalDigits is 2, then actual value is 0.01. - This parameter does not apply - to onOff, trip, vibration, waterDetection, - smokeDetection sensors." - ::= { externalSensorConfigurationEntry 23 } - -externalSensorStateChangeDelay OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The delay measured in samples before a state is asserted. - If the value is zero, then the state is asserted as soon as - it is detected; if it is non-zero, say n, then the assertion - condition must exist for n+1 consecutive samples before the corresponding - assertion event is reported. - At present, this value cannot be written (set)" - ::= { externalSensorConfigurationEntry 24 } - -externalSensorLowerCriticalThreshold OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The lower critical threshold - The value of this OID variable should be scaled by - externalSensorDecimalDigits. For example, if the value is 1 and - externalSensorDecimalDigits is 2, then actual value is 0.01. - This parameter does not apply - to onOff, trip, vibration, waterDetection, - smokeDetection sensors." - ::= { externalSensorConfigurationEntry 31 } - -externalSensorLowerWarningThreshold OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The lower non-critical (warning) threshold - The value of this OID variable should be scaled by - externalSensorDecimalDigits. For example, if the value is 1 and - externalSensorDecimalDigits is 2, then actual value is 0.01. - This parameter does not apply - to onOff, trip, vibration, waterDetection, - smokeDetection sensors." - ::= { externalSensorConfigurationEntry 32 } - -externalSensorUpperCriticalThreshold OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The upper critical threshold - The value of this OID variable should be scaled by - externalSensorDecimalDigits. For example, if the value is 1 and - externalSensorDecimalDigits is 2, then actual value is 0.01. - This parameter does not apply - to onOff, trip, vibration, waterDetection, - smokeDetection sensors." - ::= { externalSensorConfigurationEntry 33 } - -externalSensorUpperWarningThreshold OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The upper non-critical (warning) threshold - The value of this OID variable should be scaled by - externalSensorDecimalDigits. For example, if the value is 1 and - externalSensorDecimalDigits is 2, then actual value is 0.01. - This parameter does not apply - to onOff, trip, vibration, waterDetection, - smokeDetection sensors." - ::= { externalSensorConfigurationEntry 34 } - - -externalSensorEnabledThresholds OBJECT-TYPE - SYNTAX BITS{ - lowerCritical(0), - lowerWarning(1), - upperWarning(2), - upperCritical(3) - } - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "A bit string which indicates which thresholds are enabled. - This parameter does not apply - to onOff, trip, vibration, waterDetection, - smokeDetection sensors - " - ::= { externalSensorConfigurationEntry 35} - - -externalSensorIsActuator OBJECT-TYPE - SYNTAX TruthValue - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "Is this an actuator? - True: It is an actuator - False: It is not an actuator" - ::= { externalSensorConfigurationEntry 36 } - - -externalSensorPosition OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The position of the sensor. - The format is a semicolon separated list of Keyword:value pairs - Keyword1:Value1;Keyword2:value2;... - Keyword can be one of the following: ONBOARD,DEVICE-1WIREPORT;HUBPORT,CHAIN-POSITION - Examples - 1) Onboard Sensor - ONBOARD:CC1 - 2) Old sensor connected to device 1-wire port - DEVICE-1WIREPORT:2 - 3) Old sensor connected to hub port - DEVICE-1WIREPORT:2;HUBPORT:3 - 4) New style sensor connected to device 1-wire port - DEVICE-1WIREPORT:2;CHAIN-POSITION:3 - 5) Old style sensor connected to end of new style sensor chain - DEVICE-1WIREPORT:2;CHAIN-POSITION:7 - " - ::= { externalSensorConfigurationEntry 37 } - - -externalSensorUseDefaultThresholds OBJECT-TYPE - SYNTAX TruthValue - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "Use default thresholds for this sensor? - True: Use Default thresholds for this sensor - - False: Do not Use Default thresholds for this sensor" - ::= { externalSensorConfigurationEntry 38 } +externalSensorUseDefaultThresholds OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Use default thresholds for this sensor? + True: Use default thresholds from externalSensorTypeDefaultThresholdsTable + False: Use sensor-specific thresholds from this table" + ::= { externalSensorConfigurationEntry 38 } externalSensorAlarmedToNormalDelay OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The delay in seconds for transitions from the alarmed state to the normal state. - If the sensor type is motionDetection, - then it can set to a value greater >= 0 - For all other sensor types, - the value is 0 and cannot be set to any other value. - " - ::= { externalSensorConfigurationEntry 39 } + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The delay (in seconds) before the sensor returns from alarmed to normal. + This is supported for motion detectors only. For all other sensors the + value is 0 and cannot be set to any other value." + ::= { externalSensorConfigurationEntry 39 } +-- externalSensorTypeDefaultThresholdsTable: Default thresholds for each external sensor type --- This table applies only to G1 External sensors. --- This table is used for bulk configuration of G1 External sensors. +externalSensorTypeDefaultThresholdsTable OBJECT-TYPE + SYNTAX SEQUENCE OF ExternalSensorTypeDefaultThresholdsEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table listing the default thresholds for each sensor type. + The table contains a row for each supported type of external sensor + with a numeric reading." + ::= { externalSensors 4 } - - -externalSensorTypeDefaultThresholdsTable OBJECT-TYPE - SYNTAX SEQUENCE OF ExternalSensorTypeDefaultThresholdsEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A list of entries listing the default thresholds for each sensor type. " - ::= { externalSensors 4 } - -externalSensorTypeDefaultThresholdsEntry OBJECT-TYPE - SYNTAX ExternalSensorTypeDefaultThresholdsEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "An entry containing default thresholds for a sensor type." - INDEX { pduId, sensorType } - ::= { externalSensorTypeDefaultThresholdsTable 1 } +externalSensorTypeDefaultThresholdsEntry OBJECT-TYPE + SYNTAX ExternalSensorTypeDefaultThresholdsEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing default thresholds for a sensor type." + INDEX { pduId, sensorType } + ::= { externalSensorTypeDefaultThresholdsTable 1 } ExternalSensorTypeDefaultThresholdsEntryStruct ::= SEQUENCE { - externalSensorTypeDefaultHysteresis Unsigned32, - externalSensorTypeDefaultStateChangeDelay Unsigned32, - externalSensorTypeDefaultLowerCriticalThreshold Integer32, - externalSensorTypeDefaultLowerWarningThreshold Integer32, - externalSensorTypeDefaultUpperCriticalThreshold Integer32, - externalSensorTypeDefaultUpperWarningThreshold Integer32, - externalSensorTypeDefaultEnabledThresholds BITS - - } + externalSensorTypeDefaultHysteresis Unsigned32, + externalSensorTypeDefaultStateChangeDelay Unsigned32, + externalSensorTypeDefaultLowerCriticalThreshold Integer32, + externalSensorTypeDefaultLowerWarningThreshold Integer32, + externalSensorTypeDefaultUpperCriticalThreshold Integer32, + externalSensorTypeDefaultUpperWarningThreshold Integer32, + externalSensorTypeDefaultEnabledThresholds BITS + } +externalSensorTypeDefaultHysteresis OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The hysteresis used when crossing a threshold towards the normal state. + The value of this OID variable should be scaled by + externalSensorDecimalDigits. For example, if the value is 1 and + externalSensorDecimalDigits is 2, then actual value is 0.01." + ::= { externalSensorTypeDefaultThresholdsEntry 3 } +externalSensorTypeDefaultStateChangeDelay OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The delay measured in samples before a state is asserted. + If the value is zero, then the state is asserted as soon as + it is detected; if it is non-zero, say n, then the assertion + condition must exist for n+1 consecutive samples before the + event is reported." + ::= { externalSensorTypeDefaultThresholdsEntry 4 } +externalSensorTypeDefaultLowerCriticalThreshold OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The lower critical threshold + The value of this OID variable should be scaled by + externalSensorDecimalDigits. For example, if the value is 1 and + externalSensorDecimalDigits is 2, then actual value is 0.01." + ::= { externalSensorTypeDefaultThresholdsEntry 5 } -externalSensorTypeDefaultHysteresis OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The hysteresis used for deassertions - The value of this OID variable should be scaled by - externalSensorDecimalDigits. For example, if the value is 1 and - externalSensorDecimalDigits is 2, then actual value is 0.01. - This parameter does not apply - to onOff, trip, vibration, waterDetection, - smokeDetection sensors." - ::= { externalSensorTypeDefaultThresholdsEntry 3 } +externalSensorTypeDefaultLowerWarningThreshold OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The lower warning threshold + The value of this OID variable should be scaled by + externalSensorDecimalDigits. For example, if the value is 1 and + externalSensorDecimalDigits is 2, then actual value is 0.01." + ::= { externalSensorTypeDefaultThresholdsEntry 6 } -externalSensorTypeDefaultStateChangeDelay OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The delay measured in samples before a state is asserted. - If the value is zero, then the state is asserted as soon as - it is detected; if it is non-zero, say n, then the assertion - condition must exist for n+1 consecutive samples before the corresponding - assertion event is reported. - At present, this value cannot be written (set)" - ::= { externalSensorTypeDefaultThresholdsEntry 4 } +externalSensorTypeDefaultUpperCriticalThreshold OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The upper critical threshold + The value of this OID variable should be scaled by + externalSensorDecimalDigits. For example, if the value is 1 and + externalSensorDecimalDigits is 2, then actual value is 0.01." + ::= { externalSensorTypeDefaultThresholdsEntry 7 } -externalSensorTypeDefaultLowerCriticalThreshold OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The lower critical threshold - The value of this OID variable should be scaled by - externalSensorDecimalDigits. For example, if the value is 1 and - externalSensorDecimalDigits is 2, then actual value is 0.01. - This parameter does not apply - to onOff, trip, vibration, waterDetection, - smokeDetection sensors." - ::= { externalSensorTypeDefaultThresholdsEntry 5 } +externalSensorTypeDefaultUpperWarningThreshold OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The upper warning threshold + The value of this OID variable should be scaled by + externalSensorDecimalDigits. For example, if the value is 1 and + externalSensorDecimalDigits is 2, then actual value is 0.01." + ::= { externalSensorTypeDefaultThresholdsEntry 8 } +externalSensorTypeDefaultEnabledThresholds OBJECT-TYPE + SYNTAX BITS { lowerCritical(0), + lowerWarning(1), + upperWarning(2), + upperCritical(3) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "A bit string indicating which thresholds are enabled." + ::= { externalSensorTypeDefaultThresholdsEntry 9} +-- serverReachabilityTable: Settings for the server reachability feature -externalSensorTypeDefaultLowerWarningThreshold OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The lower non-critical (warning) threshold - The value of this OID variable should be scaled by - externalSensorDecimalDigits. For example, if the value is 1 and - externalSensorDecimalDigits is 2, then actual value is 0.01. - This parameter does not apply - to onOff, trip, vibration, waterDetection, - smokeDetection sensors." - ::= { externalSensorTypeDefaultThresholdsEntry 6 } +serverReachabilityTable OBJECT-TYPE + SYNTAX SEQUENCE OF ServerReachabilityEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of server entries. The number of + entries is given by the value of serverCount for the PDU." + ::= { serverReachability 3 } +serverReachabilityEntry OBJECT-TYPE + SYNTAX ServerReachabilityEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing parameters for a server." + INDEX { pduId, serverID } + ::= { serverReachabilityTable 1 } -externalSensorTypeDefaultUpperCriticalThreshold OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The upper critical threshold - The value of this OID variable should be scaled by - externalSensorDecimalDigits. For example, if the value is 1 and - externalSensorDecimalDigits is 2, then actual value is 0.01. - This parameter does not apply - to onOff, trip, vibration, waterDetection, - smokeDetection sensors." - ::= { externalSensorTypeDefaultThresholdsEntry 7 } +ServerReachabilityEntryStruct ::= SEQUENCE { + serverID Integer32, + serverIPAddress DisplayString, + serverPingEnabled TruthValue + } +serverID OBJECT-TYPE + SYNTAX Integer32(1..256) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A unique value for each server. Its value + ranges between 1 and the value of serverCount for that PDU" + ::= { serverReachabilityEntry 1 } -externalSensorTypeDefaultUpperWarningThreshold OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The upper non-critical (warning) threshold - The value of this OID variable should be scaled by - externalSensorDecimalDigits. For example, if the value is 1 and - externalSensorDecimalDigits is 2, then actual value is 0.01. - This parameter does not apply - to onOff, trip, vibration, waterDetection, - smokeDetection sensors." - ::= { externalSensorTypeDefaultThresholdsEntry 8 } +serverIPAddress OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The IP Address/host name of the server" + ::= { serverReachabilityEntry 3 } +serverPingEnabled OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is ping enabled for this server?" + ::= { serverReachabilityEntry 4 } -externalSensorTypeDefaultEnabledThresholds OBJECT-TYPE - SYNTAX BITS{ - lowerCritical(0), - lowerWarning(1), - upperWarning(2), - upperCritical(3) - } - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "A bit string which indicates which thresholds are enabled. - This parameter does not apply - to onOff, trip, vibration, waterDetection, - smokeDetection sensors - " - ::= { externalSensorTypeDefaultThresholdsEntry 9} +-- wireConfigurationTable: Information about wire objects in the PDU +wireConfigurationTable OBJECT-TYPE + SYNTAX SEQUENCE OF WireConfigurationEntryStruct + MAX-ACCESS not-accessible + STATUS deprecated + DESCRIPTION + "A list of wire configuration entries. The number of + entries is given by the value of wireCount for the PDU. + Note: This feature is no longer used, the table is always empty." + ::= { wires 3 } - - - - --- the server reachability table - --- The server Reachability table contains information on the ping feature. - - - - -serverReachabilityTable OBJECT-TYPE - SYNTAX SEQUENCE OF ServerReachabilityEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A list of server entries. The number of - entries is given by the value of serverCount for the PDU." - ::= { serverReachability 3 } - -serverReachabilityEntry OBJECT-TYPE - SYNTAX ServerReachabilityEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "An entry containing parameters for a server." - INDEX { pduId, serverID } - ::= { serverReachabilityTable 1 } - -ServerReachabilityEntryStruct ::= SEQUENCE {serverID Integer32, - serverIPAddress DisplayString, - serverPingEnabled TruthValue - } - -serverID OBJECT-TYPE - SYNTAX Integer32(1..256) - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A unique value for each server. Its value - ranges between 1 and the value of serverCount for that PDU" - ::= { serverReachabilityEntry 1 } - - - - - -serverIPAddress OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The IP Address/host name of the server" - ::= { serverReachabilityEntry 3 } - - -serverPingEnabled OBJECT-TYPE - SYNTAX TruthValue - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "Is ping enabled for this server?" - ::= { serverReachabilityEntry 4 } - - --- the wireConfiguration table - --- The wireConfiguration table contains information on the PDU's wires. - - -wireConfigurationTable OBJECT-TYPE - SYNTAX SEQUENCE OF WireConfigurationEntryStruct - MAX-ACCESS not-accessible - STATUS deprecated - DESCRIPTION - "A list of wire configuration entries. The number of - entries is given by the value of wireCount for the PDU." - ::= { wires 3 } - -wireConfigurationEntry OBJECT-TYPE - SYNTAX WireConfigurationEntryStruct - MAX-ACCESS not-accessible - STATUS deprecated - DESCRIPTION - "An entry containing objects for a particular wire." - INDEX { pduId, wireId } - ::= { wireConfigurationTable 1 } +wireConfigurationEntry OBJECT-TYPE + SYNTAX WireConfigurationEntryStruct + MAX-ACCESS not-accessible + STATUS deprecated + DESCRIPTION + "An entry containing objects for a particular wire." + INDEX { pduId, wireId } + ::= { wireConfigurationTable 1 } WireConfigurationEntryStruct ::= SEQUENCE { - wireId Integer32, - wireLabel DisplayString, - wireCapabilities BITS, - wirePowerSource RowPointer - } + wireId Integer32, + wireLabel DisplayString, + wireCapabilities BITS, + wirePowerSource RowPointer + } -wireId OBJECT-TYPE - SYNTAX Integer32(1..256) - MAX-ACCESS not-accessible - STATUS deprecated - DESCRIPTION - "A unique value for each wire. Its value - ranges between 1 and the value of wireCount." - ::= { wireConfigurationEntry 1 } +wireId OBJECT-TYPE + SYNTAX Integer32(1..256) + MAX-ACCESS not-accessible + STATUS deprecated + DESCRIPTION + "A unique value for each wire. Its value + ranges between 1 and the value of wireCount." + ::= { wireConfigurationEntry 1 } -wireLabel OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS read-only - STATUS deprecated - DESCRIPTION - "The label on the PDU identifying the wire." - ::= { wireConfigurationEntry 2 } +wireLabel OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The label on the PDU identifying the wire." + ::= { wireConfigurationEntry 2 } -wireCapabilities OBJECT-TYPE - SYNTAX BITS { - rmsCurrent(0), - peakCurrent(1), - unbalancedCurrent(2), - rmsVoltage(3), - activePower(4), - apparentPower(5), - powerFactor(6), - activeEnergy(7), - apparentEnergy(8) - } - MAX-ACCESS read-only - STATUS deprecated - DESCRIPTION - "A bit string which indicates which wire sensors are available." - ::= { wireConfigurationEntry 3 } +wireCapabilities OBJECT-TYPE + SYNTAX BITS { rmsCurrent(0), + peakCurrent(1), + unbalancedCurrent(2), + rmsVoltage(3), + activePower(4), + apparentPower(5), + powerFactor(6), + activeEnergy(7), + apparentEnergy(8) } + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "A bit string indicating which wire sensors are available." + ::= { wireConfigurationEntry 3 } +wirePowerSource OBJECT-TYPE + SYNTAX RowPointer + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "This object allows discovery of how the PDU is wired. It indicates the + wire's power source which can one of the following: + - an inlet + - an overcurrent protector + - a transfer switch -wirePowerSource OBJECT-TYPE - SYNTAX RowPointer - MAX-ACCESS read-only - STATUS deprecated - DESCRIPTION - "This object allows discovery of how the PDU is wired. It indicates the - wire's power source which can one of the following: - overCurrentProtector - transfer switch - inlet + If the power source is an inlet, it contains the OID of + an inletLabel in the inletConfigurationTable. The indices of the OID can + then be used to reference other objects in the inlet tables. - If the power source is an OverCurrentProtector, it - contains the OID of an overCurrentProtectorLabel in the - overCurrentProtectorConfiguration Table. The index of the OID can then be - used to reference other objects in the overCurrentProtectorConfigurationTable. + If the power source is an overcurrent protector, it + contains the OID of an overCurrentProtectorLabel in the + overCurrentProtectorConfigurationTable. The indices of the OID can then be + used to reference other objects in the overcurrent protector tables. - If the power source is an inlet, it contains the OID of - an inletLabel in the inletConfigurationTable. The index of the OID can - then be used to reference other objects in the inletConfigurationTable. + If the power source is a transfer switch, it + contains the OID of a transferSwitchLabel in the + transferSwitchConfigurationTable. The indices of the OID can then be + used to reference other objects in the transfer switch tables." + ::= { wireConfigurationEntry 4 } - If the power source is a transferSwitch, it - contains the OID of a transferSwitchLabel in the - transferSwitchConfiguration Table. The index of the OID can then be - used to reference other objects in the transferSwitchConfigurationTable. - - " - ::= { wireConfigurationEntry 4} +-- wireSensorConfigurationTable: information and settings for wire sensors +wireSensorConfigurationTable OBJECT-TYPE + SYNTAX SEQUENCE OF WireSensorConfigurationEntryStruct + MAX-ACCESS not-accessible + STATUS deprecated + DESCRIPTION + "A list of wire sensor configuration entries. + Note: This feature is no longer used, the table is always empty." + ::= { wires 4 } - - - - - --- The wireSensorConfiguration table contains information on the PDU's wire Sensors. - -wireSensorConfigurationTable OBJECT-TYPE - SYNTAX SEQUENCE OF WireSensorConfigurationEntryStruct - MAX-ACCESS not-accessible - STATUS deprecated - DESCRIPTION - "A list of wireSensor configuration entries." - ::= { wires 4 } - -wireSensorConfigurationEntry OBJECT-TYPE - SYNTAX WireSensorConfigurationEntryStruct - MAX-ACCESS not-accessible - STATUS deprecated - DESCRIPTION - "An wireSensor entry containing objects for a - particular wire Sensor." - INDEX { pduId, wireId, sensorType } - ::= { wireSensorConfigurationTable 1 } +wireSensorConfigurationEntry OBJECT-TYPE + SYNTAX WireSensorConfigurationEntryStruct + MAX-ACCESS not-accessible + STATUS deprecated + DESCRIPTION + "An wireSensor entry containing objects for a particular wire Sensor." + INDEX { pduId, wireId, sensorType } + ::= { wireSensorConfigurationTable 1 } WireSensorConfigurationEntryStruct ::= SEQUENCE { - wireSensorLogAvailable TruthValue, - wireSensorUnits SensorUnitsEnumeration, - wireSensorDecimalDigits Unsigned32, - wireSensorAccuracy HundredthsOfAPercentage, - wireSensorResolution Unsigned32, - wireSensorTolerance Unsigned32, - wireSensorMaximum Unsigned32, - wireSensorMinimum Unsigned32, - wireSensorHysteresis Unsigned32, - wireSensorStateChangeDelay Unsigned32, - wireSensorLowerCriticalThreshold Unsigned32, - wireSensorLowerWarningThreshold Unsigned32, - wireSensorUpperCriticalThreshold Unsigned32, - wireSensorUpperWarningThreshold Unsigned32, - wireSensorEnabledThresholds BITS - } + wireSensorLogAvailable TruthValue, + wireSensorUnits SensorUnitsEnumeration, + wireSensorDecimalDigits Unsigned32, + wireSensorAccuracy HundredthsOfAPercentage, + wireSensorResolution Unsigned32, + wireSensorTolerance Unsigned32, + wireSensorMaximum Unsigned32, + wireSensorMinimum Unsigned32, + wireSensorHysteresis Unsigned32, + wireSensorStateChangeDelay Unsigned32, + wireSensorLowerCriticalThreshold Unsigned32, + wireSensorLowerWarningThreshold Unsigned32, + wireSensorUpperCriticalThreshold Unsigned32, + wireSensorUpperWarningThreshold Unsigned32, + wireSensorEnabledThresholds BITS + } -wireSensorLogAvailable OBJECT-TYPE - SYNTAX TruthValue - MAX-ACCESS read-write - STATUS deprecated - DESCRIPTION - "Is logging available for this sensor?" - ::= { wireSensorConfigurationEntry 4 } +wireSensorLogAvailable OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS deprecated + DESCRIPTION + "Is data logging enabled for this sensor?" + ::= { wireSensorConfigurationEntry 4 } +wireSensorUnits OBJECT-TYPE + SYNTAX SensorUnitsEnumeration + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The unit in which the sensor reading is reported. + This parameter does not apply to sensors without numerical reading." + ::= { wireSensorConfigurationEntry 6 } -wireSensorUnits OBJECT-TYPE - SYNTAX SensorUnitsEnumeration - MAX-ACCESS read-only - STATUS deprecated - DESCRIPTION - "The base units" - ::= { wireSensorConfigurationEntry 6 } +wireSensorDecimalDigits OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The number of digits displayed to the right of the decimal point. + This parameter does not apply to sensors without numerical reading." + ::= { wireSensorConfigurationEntry 7 } -wireSensorDecimalDigits OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS deprecated - DESCRIPTION - "The number of digits displayed to the right of the decimal point." - ::= { wireSensorConfigurationEntry 7 } +wireSensorAccuracy OBJECT-TYPE + SYNTAX HundredthsOfAPercentage + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The accuracy: the maximum relative difference (in percent) between + measurement and the actual value. + This parameter does not apply to sensors without numerical reading." + ::= { wireSensorConfigurationEntry 8 } -wireSensorAccuracy OBJECT-TYPE - SYNTAX HundredthsOfAPercentage - MAX-ACCESS read-only - STATUS deprecated - DESCRIPTION - "The accuracy: how close (in percent) the measurement is to the actual value" - ::= { wireSensorConfigurationEntry 8 } +wireSensorResolution OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The resolution: the minimum difference between any two measured values + The value of this OID variable should be scaled by + wireSensorDecimalDigits. For example, if the value is 1 and + wireSensorDecimalDigits is 2, then actual value is 0.01. + This parameter does not apply to sensors without numerical reading." + ::= { wireSensorConfigurationEntry 9 } -wireSensorResolution OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS deprecated - DESCRIPTION - "The resolution: the minimum difference between any two measured values - The value of this OID variable should be scaled by - wireSensorDecimalDigits. For example, if the value is 1 and - wireSensorDecimalDigits is 2, then actual value is 0.01." - ::= { wireSensorConfigurationEntry 9 } +wireSensorTolerance OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The tolerance: the maximum difference between measurement and the + actual value. The value of this OID variable should be scaled by + (wireSensorDecimalDigits + 1). For example, if the value is 50 and + wireSensorDecimalDigits is 2, then actual value is 0.05. + This parameter does not apply to sensors without numerical reading." + ::= { wireSensorConfigurationEntry 10 } -wireSensorTolerance OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS deprecated - DESCRIPTION - "The resolution: the difference between a sensor value and the actual value - The value of this OID variable should be scaled by - (wireSensorDecimalDigits + 1). For example, if the value is 50 and - wireSensorDecimalDigits is 2, then actual value is 0.05." - ::= { wireSensorConfigurationEntry 10 } +wireSensorMaximum OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The largest possible value + The value of this OID variable should be scaled by + wireSensorDecimalDigits. For example, if the value is 1 and + wireSensorDecimalDigits is 2, then actual value is 0.01. + This parameter does not apply to sensors without numerical reading." + ::= { wireSensorConfigurationEntry 11 } -wireSensorMaximum OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS deprecated - DESCRIPTION - "The largest possible value - The value of this OID variable should be scaled by - wireSensorDecimalDigits. For example, if the value is 1 and - wireSensorDecimalDigits is 2, then actual value is 0.01." - ::= { wireSensorConfigurationEntry 11 } +wireSensorMinimum OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The smallest possible value + The value of this OID variable should be scaled by + wireSensorDecimalDigits. For example, if the value is 1 and + wireSensorDecimalDigits is 2, then actual value is 0.01. + This parameter does not apply to sensors without numerical reading." + ::= { wireSensorConfigurationEntry 12 } -wireSensorMinimum OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS deprecated - DESCRIPTION - "The smallest possible value - The value of this OID variable should be scaled by - wireSensorDecimalDigits. For example, if the value is 1 and - wireSensorDecimalDigits is 2, then actual value is 0.01." - ::= { wireSensorConfigurationEntry 12 } +wireSensorHysteresis OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS deprecated + DESCRIPTION + "The hysteresis used when crossing a threshold towards the normal state. + The value of this OID variable should be scaled by + wireSensorDecimalDigits. For example, if the value is 1 and + wireSensorDecimalDigits is 2, then actual value is 0.01. + This parameter does not apply to sensors without numerical reading." + ::= { wireSensorConfigurationEntry 13 } -wireSensorHysteresis OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS deprecated - DESCRIPTION - "The hysteresis used for deassertions - The value of this OID variable should be scaled by - wireSensorDecimalDigits. For example, if the value is 1 and - wireSensorDecimalDigits is 2, then actual value is 0.01." - ::= { wireSensorConfigurationEntry 13 } +wireSensorStateChangeDelay OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS deprecated + DESCRIPTION + "The delay measured in samples before a state is asserted. + If the value is zero, then the state is asserted as soon as + it is detected; if it is non-zero, say n, then the assertion + condition must exist for n+1 consecutive samples before the + event is reported. + This parameter does not apply to sensors without numerical reading." + ::= { wireSensorConfigurationEntry 14 } -wireSensorStateChangeDelay OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS deprecated - DESCRIPTION - "The delay measured in samples before a state is asserted. - If the value is zero, then the state is asserted as soon as - it is detected; if it is non-zero, say n, then the assertion - condition must exist for n+1 consecutive samples before the corresponding - assertion event is reported. - At present, this value cannot be written (set)" - ::= { wireSensorConfigurationEntry 14 } +wireSensorLowerCriticalThreshold OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS deprecated + DESCRIPTION + "The lower critical threshold + The value of this OID variable should be scaled by + wireSensorDecimalDigits. For example, if the value is 1 and + wireSensorDecimalDigits is 2, then actual value is 0.01. + This parameter does not apply to sensors without numerical reading." + ::= { wireSensorConfigurationEntry 21 } -wireSensorLowerCriticalThreshold OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS deprecated - DESCRIPTION - "The lower critical threshold - The value of this OID variable should be scaled by - wireSensorDecimalDigits. For example, if the value is 1 and - wireSensorDecimalDigits is 2, then actual value is 0.01." - ::= { wireSensorConfigurationEntry 21 } +wireSensorLowerWarningThreshold OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS deprecated + DESCRIPTION + "The lower non-critical (warning) threshold + The value of this OID variable should be scaled by + wireSensorDecimalDigits. For example, if the value is 1 and + wireSensorDecimalDigits is 2, then actual value is 0.01. + This parameter does not apply to sensors without numerical reading." + ::= { wireSensorConfigurationEntry 22 } -wireSensorLowerWarningThreshold OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS deprecated - DESCRIPTION - "The lower non-critical (warning) threshold - The value of this OID variable should be scaled by - wireSensorDecimalDigits. For example, if the value is 1 and - wireSensorDecimalDigits is 2, then actual value is 0.01." - ::= { wireSensorConfigurationEntry 22 } +wireSensorUpperCriticalThreshold OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS deprecated + DESCRIPTION + "The upper critical threshold + The value of this OID variable should be scaled by + wireSensorDecimalDigits. For example, if the value is 1 and + wireSensorDecimalDigits is 2, then actual value is 0.01. + This parameter does not apply to sensors without numerical reading." + ::= { wireSensorConfigurationEntry 23 } -wireSensorUpperCriticalThreshold OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS deprecated - DESCRIPTION - "The upper critical threshold - The value of this OID variable should be scaled by - wireSensorDecimalDigits. For example, if the value is 1 and - wireSensorDecimalDigits is 2, then actual value is 0.01." - ::= { wireSensorConfigurationEntry 23 } +wireSensorUpperWarningThreshold OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS deprecated + DESCRIPTION + "The upper non-critical (warning) threshold + The value of this OID variable should be scaled by + wireSensorDecimalDigits. For example, if the value is 1 and + wireSensorDecimalDigits is 2, then actual value is 0.01. + This parameter does not apply to sensors without numerical reading." + ::= { wireSensorConfigurationEntry 24 } -wireSensorUpperWarningThreshold OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS deprecated - DESCRIPTION - "The upper non-critical (warning) threshold - The value of this OID variable should be scaled by - wireSensorDecimalDigits. For example, if the value is 1 and - wireSensorDecimalDigits is 2, then actual value is 0.01." - ::= { wireSensorConfigurationEntry 24 } +wireSensorEnabledThresholds OBJECT-TYPE + SYNTAX BITS { lowerCritical(0), + lowerWarning(1), + upperWarning(2), + upperCritical(3) } + MAX-ACCESS read-write + STATUS deprecated + DESCRIPTION + "A bit string indicating which thresholds are enabled. + This parameter does not apply to sensors without numerical reading." + ::= { wireSensorConfigurationEntry 25 } -wireSensorEnabledThresholds OBJECT-TYPE - SYNTAX BITS { - lowerCritical(0), - lowerWarning(1), - upperWarning(2), - upperCritical(3) - } - MAX-ACCESS read-write - STATUS deprecated - DESCRIPTION - "A bit string which indicates which thresholds are enabled." - ::= { wireSensorConfigurationEntry 25 } +-- transferSwitchConfigurationTable: transfer switch information and settings +transferSwitchConfigurationTable OBJECT-TYPE + SYNTAX SEQUENCE OF TransferSwitchConfigurationEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of transfer switch configuration entries. The number of + entries is given by the value of transferSwitchCount." + ::= { transferSwitch 3 } +transferSwitchConfigurationEntry OBJECT-TYPE + SYNTAX TransferSwitchConfigurationEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing objects for a particular transfer switch." + INDEX { pduId, transferSwitchId } + ::= { transferSwitchConfigurationTable 1 } +TransferSwitchConfigurationEntryStruct ::= SEQUENCE { + transferSwitchId Integer32, + transferSwitchLabel DisplayString, + transferSwitchName DisplayString, + transferSwitchPreferredInlet Integer32, + transferSwitchPoleCount Integer32, + transferSwitchAutoReTransferEnabled TruthValue, + transferSwitchAutoReTransferWaitTime Unsigned32, + transferSwitchAutoReTransferRequiresPhaseSync TruthValue, + transferSwitchFrontPanelManualTransferButtonEnabled TruthValue, + transferSwitchCapabilities BITS, + transferSwitchPowerSource1 RowPointer, + transferSwitchPowerSource2 RowPointer + } --- the transferSwitchConfiguration table +transferSwitchId OBJECT-TYPE + SYNTAX Integer32(1..256) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A unique value for each transfer switch. Its value + ranges between 1 and the value of transferSwitchCount." + ::= { transferSwitchConfigurationEntry 1 } --- The tsConfiguration table contains information on the TS ( Transfer Switch). +transferSwitchLabel OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The label on the PDU identifying the transfer switch." + ::= { transferSwitchConfigurationEntry 2 } +transferSwitchName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The user-defined name of the transfer switch." + ::= { transferSwitchConfigurationEntry 3 } -transferSwitchConfigurationTable OBJECT-TYPE - SYNTAX SEQUENCE OF TransferSwitchConfigurationEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A list of transfer switch configuration entries. The number of - entries is given by the value of transferSwitchCount." - ::= { transferSwitch 3 } +transferSwitchPreferredInlet OBJECT-TYPE + SYNTAX Integer32(1..64) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The preferred inlet. This is the inlet to be selected in case both + inlets have acceptable power." + ::= { transferSwitchConfigurationEntry 4 } -transferSwitchConfigurationEntry OBJECT-TYPE - SYNTAX TransferSwitchConfigurationEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "An entry containing objects for a particular transferSwitch." - INDEX { pduId, transferSwitchId } - ::= { transferSwitchConfigurationTable 1 } +transferSwitchPoleCount OBJECT-TYPE + SYNTAX Integer32(2..4) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of poles." + ::= { transferSwitchConfigurationEntry 5 } -TransferSwitchConfigurationEntryStruct ::= SEQUENCE { transferSwitchId Integer32, - transferSwitchLabel DisplayString, - transferSwitchName DisplayString, - transferSwitchPreferredInlet Integer32, - transferSwitchAutoReTransferEnabled TruthValue, - transferSwitchAutoReTransferWaitTime Unsigned32, - transferSwitchAutoReTransferRequiresPhaseSync TruthValue, - transferSwitchFrontPanelManualTransferButtonEnabled TruthValue, - transferSwitchCapabilities BITS, - transferSwitchPowerSource1 RowPointer, - transferSwitchPowerSource2 RowPointer - } +transferSwitchAutoReTransferEnabled OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables or disables automatic retransfer from the standby inlet to + the preferred inlet after power has been restored." + ::= { transferSwitchConfigurationEntry 20 } +transferSwitchAutoReTransferWaitTime OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The delay for automatic retransfers. Retransfer occurs this many + seconds after the condition causing the original transfer has been + corrected." + ::= { transferSwitchConfigurationEntry 21 } -transferSwitchId OBJECT-TYPE - SYNTAX Integer32(1..256) - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A unique value for each transfer switch. Its value - ranges between 1 and the value of transferSwitchCount." - ::= { transferSwitchConfigurationEntry 1 } +transferSwitchAutoReTransferRequiresPhaseSync OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables or disables automatic retransfer in case the two inlets are + not synchronized. If set to True, automatic retransfer is inhibited while + a phase sync alarm is present, i.e. the phase difference between the two + inlets is too large." + ::= { transferSwitchConfigurationEntry 22 } -transferSwitchLabel OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The label on the PDU identifying the TS." - ::= { transferSwitchConfigurationEntry 2 } +transferSwitchFrontPanelManualTransferButtonEnabled OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Enables or disables the Manual Transfer button on the unit's front panel." + ::= { transferSwitchConfigurationEntry 23 } -transferSwitchName OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The user-defined name of the transferSwitch." - ::= { transferSwitchConfigurationEntry 3 } +transferSwitchCapabilities OBJECT-TYPE + SYNTAX BITS { overloadStatus(32), + inletPhaseSyncAngle(37), + inletPhaseSync(38), + operatingState(39), + activeInlet(40), + switchStatus(47) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A bit string indicating which sensors are available for the transfer switch." + ::= { transferSwitchConfigurationEntry 24 } -transferSwitchPreferredInlet OBJECT-TYPE - SYNTAX Integer32(1..64) - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The preferred Inlet. The TS powers the outlet from the preferred inlet when acceptable power - is available from the preferred inlet. " - ::= { transferSwitchConfigurationEntry 4 } +transferSwitchPowerSource1 OBJECT-TYPE + SYNTAX RowPointer + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object allows discovery of how the PDU is wired. It indicates the + transfer switch's first power source, typically a fuse. + It contains the OID of an overCurrentProtectorLabel in the + overCurrentProtectorConfiguration Table. The indices of the OID can then be + used to reference other objects in the overcurrent protector tables." + ::= { transferSwitchConfigurationEntry 31 } -transferSwitchAutoReTransferEnabled OBJECT-TYPE - SYNTAX TruthValue - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The TS can be configured to automatically retransfer back to the preferred inlet when power is restored. - Re-transfer only occurs if this variable is true." - ::= { transferSwitchConfigurationEntry 20 } +transferSwitchPowerSource2 OBJECT-TYPE + SYNTAX RowPointer + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object allows discovery of how the PDU is wired. It indicates the + transfer switch's second power source, typically a fuse. + It contains the OID of an overCurrentProtectorLabel in the + overCurrentProtectorConfiguration Table. The indices of the OID can then be + used to reference other objects in the overcurrent protector tables." + ::= { transferSwitchConfigurationEntry 32 } -transferSwitchAutoReTransferWaitTime OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The Auto Re-Transfer Wait Time. Re-transfer occurs this many seconds after the condition causing the - original transfer has been corrected." - ::= { transferSwitchConfigurationEntry 21 } +-- transferSwitchPoleConfigurationTable: transfer switch pole information +transferSwitchPoleConfigurationTable OBJECT-TYPE + SYNTAX SEQUENCE OF TransferSwitchPoleConfigurationEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of transfer switch pole configuration entries. The number of + entries is given by the value of transferSwitchPoleCount." + ::= { transferSwitch 5 } -transferSwitchAutoReTransferRequiresPhaseSync OBJECT-TYPE - SYNTAX TruthValue - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "If this parameter is False, then do not retransfer if there is a PHASE_SYNC_FAULT in effect. A - PHASE_SYNC_FAULT occurs when the phase difference between the inlets is too high." - ::= { transferSwitchConfigurationEntry 22 } +transferSwitchPoleConfigurationEntry OBJECT-TYPE + SYNTAX TransferSwitchPoleConfigurationEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing parameters for a particular transfer switch pole." + INDEX { pduId, transferSwitchId, transferSwitchPoleIndex } + ::= { transferSwitchPoleConfigurationTable 1 } +TransferSwitchPoleConfigurationEntryStruct ::= SEQUENCE { + transferSwitchPoleIndex Integer32, + transferSwitchPoleLine LineEnumeration, + transferSwitchPoleIn1Node Integer32, + transferSwitchPoleIn2Node Integer32, + transferSwitchPoleOutNode Integer32 + } -transferSwitchFrontPanelManualTransferButtonEnabled OBJECT-TYPE - SYNTAX TruthValue - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "If this parameter is false, then manual transfers caused by pressing the front panel switch are disabled. " - ::= { transferSwitchConfigurationEntry 23 } +transferSwitchPoleIndex OBJECT-TYPE + SYNTAX Integer32(1..256) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A unique value for each transfer switch pole. Its value + ranges between 1 and the value of transferSwitchPoleCount." + ::= { transferSwitchPoleConfigurationEntry 1 } +transferSwitchPoleLine OBJECT-TYPE + SYNTAX LineEnumeration + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The phase for this transfer switch pole." + ::= { transferSwitchPoleConfigurationEntry 2 } -transferSwitchCapabilities OBJECT-TYPE - SYNTAX BITS { - overloadStatus(32), - inletPhaseSyncAngle(37), - inletPhaseSync(38), - operatingState(39), - activeInlet(40), - switchStatus(47) - - } - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "A bit string which indicates which sensors are available for the transfer switch." - ::= { transferSwitchConfigurationEntry 24 } +transferSwitchPoleIn1Node OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The node to which this transfer switch pole input 1 is connected" + ::= { transferSwitchPoleConfigurationEntry 3 } +transferSwitchPoleIn2Node OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The node to which this transfer switch pole input 2 is connected" + ::= { transferSwitchPoleConfigurationEntry 4 } -transferSwitchPowerSource1 OBJECT-TYPE - SYNTAX RowPointer - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "This object allows discovery of how the PDU is wired. It indicates the - transferSwitch's first power source which can one of the following: - overCurrentProtector - transfer switch - inlet +transferSwitchPoleOutNode OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The node to which this transfer switch pole output is connected" + ::= { transferSwitchPoleConfigurationEntry 5 } - If the power source is an OverCurrentProtector, it - contains the OID of an overCurrentProtectorLabel in the - overCurrentProtectorConfiguration Table. The index of the OID can then be - used to reference other objects in the overCurrentProtectorConfigurationTable. +-- transferSwitchSensorConfigurationTable: information and settings for transfer switch sensors - If the power source is an inlet, it contains the OID of - an inletLabel in the inletConfigurationTable. The index of the OID can - then be used to reference other objects in the inletConfigurationTable. +transferSwitchSensorConfigurationTable OBJECT-TYPE + SYNTAX SEQUENCE OF TransferSwitchSensorConfigurationEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of transfer switch sensor configuration entries." + ::= { transferSwitch 4 } - If the power source is a transferSwitch, it - contains the OID of a transferSwitchLabel in the - transferSwitchConfiguration Table. The index of the OID can then be - used to reference other objects in the transferSwitchConfigurationTable. - - " - ::= { transferSwitchConfigurationEntry 31 } - - - -transferSwitchPowerSource2 OBJECT-TYPE - SYNTAX RowPointer - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "This object allows discovery of how the PDU is wired. It indicates the - transferSwitch's second power source which can one of the following: - overCurrentProtector - transfer switch - inlet - - If the power source is an OverCurrentProtector, it - contains the OID of an overCurrentProtectorLabel in the - overCurrentProtectorConfiguration Table. The index of the OID can then be - used to reference other objects in the overCurrentProtectorConfigurationTable. - - If the power source is an inlet, it contains the OID of - an inletLabel in the inletConfigurationTable. The index of the OID can - then be used to reference other objects in the inletConfigurationTable. - - If the power source is a transferSwitch, it - contains the OID of a transferSwitchLabel in the - transferSwitchConfiguration Table. The index of the OID can then be - used to reference other objects in the transferSwitchConfigurationTable - - " - ::= { transferSwitchConfigurationEntry 32 } - - - - - --- The transfer switch sensor configuration table contains information on the transfer switch's sensors. - -transferSwitchSensorConfigurationTable OBJECT-TYPE - SYNTAX SEQUENCE OF TransferSwitchSensorConfigurationEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A list of transfer switch sensor configuration entries. " - ::= { transferSwitch 4 } - -transferSwitchSensorConfigurationEntry OBJECT-TYPE - SYNTAX TransferSwitchSensorConfigurationEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "An entry containing parameters for a transfer switch sensor." - INDEX { pduId, transferSwitchId, sensorType } - ::= { transferSwitchSensorConfigurationTable 1 } +transferSwitchSensorConfigurationEntry OBJECT-TYPE + SYNTAX TransferSwitchSensorConfigurationEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing parameters for a transfer switch sensor." + INDEX { pduId, transferSwitchId, sensorType } + ::= { transferSwitchSensorConfigurationTable 1 } TransferSwitchSensorConfigurationEntryStruct ::= SEQUENCE { - transferSwitchSensorLogAvailable TruthValue, - transferSwitchSensorUnits SensorUnitsEnumeration, - transferSwitchSensorDecimalDigits Unsigned32, - transferSwitchSensorAccuracy HundredthsOfAPercentage, - transferSwitchSensorResolution Unsigned32, - transferSwitchSensorTolerance Unsigned32, - transferSwitchSensorMaximum Unsigned32, - transferSwitchSensorMinimum Unsigned32, - transferSwitchSensorHysteresis Unsigned32, - transferSwitchSensorStateChangeDelay Unsigned32, - transferSwitchSensorLowerCriticalThreshold Unsigned32, - transferSwitchSensorLowerWarningThreshold Unsigned32, - transferSwitchSensorUpperCriticalThreshold Unsigned32, - transferSwitchSensorUpperWarningThreshold Unsigned32, - transferSwitchSensorEnabledThresholds BITS, - transferSwitchSensorSignedMaximum Integer32, - transferSwitchSensorSignedMinimum Integer32, - transferSwitchSensorSignedLowerCriticalThreshold Integer32, - transferSwitchSensorSignedLowerWarningThreshold Integer32, - transferSwitchSensorSignedUpperCriticalThreshold Integer32, - transferSwitchSensorSignedUpperWarningThreshold Integer32 - } + transferSwitchSensorLogAvailable TruthValue, + transferSwitchSensorUnits SensorUnitsEnumeration, + transferSwitchSensorDecimalDigits Unsigned32, + transferSwitchSensorAccuracy HundredthsOfAPercentage, + transferSwitchSensorResolution Unsigned32, + transferSwitchSensorTolerance Unsigned32, + transferSwitchSensorMaximum Unsigned32, + transferSwitchSensorMinimum Unsigned32, + transferSwitchSensorHysteresis Unsigned32, + transferSwitchSensorStateChangeDelay Unsigned32, + transferSwitchSensorLowerCriticalThreshold Unsigned32, + transferSwitchSensorLowerWarningThreshold Unsigned32, + transferSwitchSensorUpperCriticalThreshold Unsigned32, + transferSwitchSensorUpperWarningThreshold Unsigned32, + transferSwitchSensorEnabledThresholds BITS, + transferSwitchSensorSignedMaximum Integer32, + transferSwitchSensorSignedMinimum Integer32, + transferSwitchSensorSignedLowerCriticalThreshold Integer32, + transferSwitchSensorSignedLowerWarningThreshold Integer32, + transferSwitchSensorSignedUpperCriticalThreshold Integer32, + transferSwitchSensorSignedUpperWarningThreshold Integer32 + } -transferSwitchSensorLogAvailable OBJECT-TYPE - SYNTAX TruthValue - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "Is logging available for this sensor?" - ::= { transferSwitchSensorConfigurationEntry 4 } +transferSwitchSensorLogAvailable OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is data logging enabled for this sensor?" + ::= { transferSwitchSensorConfigurationEntry 4 } -transferSwitchSensorUnits OBJECT-TYPE - SYNTAX SensorUnitsEnumeration - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The base units. - This parameter does not apply to sensors without numerical reading, - e.g. operational state or switch fault sensors." - ::= { transferSwitchSensorConfigurationEntry 6 } +transferSwitchSensorUnits OBJECT-TYPE + SYNTAX SensorUnitsEnumeration + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The unit in which the sensor reading is reported. + This parameter does not apply to sensors without numerical reading." + ::= { transferSwitchSensorConfigurationEntry 6 } -transferSwitchSensorDecimalDigits OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The number of digits displayed to the right of the decimal point - This parameter does not apply to sensors without numerical reading, - e.g. operational state or switch fault sensors." - ::= { transferSwitchSensorConfigurationEntry 7 } +transferSwitchSensorDecimalDigits OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of digits displayed to the right of the decimal point + This parameter does not apply to sensors without numerical reading." + ::= { transferSwitchSensorConfigurationEntry 7 } -transferSwitchSensorAccuracy OBJECT-TYPE - SYNTAX HundredthsOfAPercentage - MAX-ACCESS read-only - STATUS deprecated - DESCRIPTION - "The accuracy: how close (in percent) the measurement is to the actual value - This parameter does not apply to sensors without numerical reading, - e.g. operational state or switch fault sensors." - ::= { transferSwitchSensorConfigurationEntry 8 } +transferSwitchSensorAccuracy OBJECT-TYPE + SYNTAX HundredthsOfAPercentage + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The accuracy: how close (in percent) the measurement is to the actual value + This parameter does not apply to sensors without numerical reading." + ::= { transferSwitchSensorConfigurationEntry 8 } -transferSwitchSensorResolution OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The resolution: the minimum difference between any two measured values - The value of this OID variable should be scaled by - transferSwitchSensorDecimalDigits. For example, if the value is 1 and - transferSwitchSensorDecimalDigits is 2, then actual value is 0.01. - This parameter does not apply to sensors without numerical reading, - e.g. operational state or switch fault sensors." - ::= { transferSwitchSensorConfigurationEntry 9 } +transferSwitchSensorResolution OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The resolution: the minimum difference between any two measured values + The value of this OID variable should be scaled by + transferSwitchSensorDecimalDigits. For example, if the value is 1 and + transferSwitchSensorDecimalDigits is 2, then actual value is 0.01. + This parameter does not apply to sensors without numerical reading." + ::= { transferSwitchSensorConfigurationEntry 9 } -transferSwitchSensorTolerance OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS deprecated - DESCRIPTION - "The resolution: the difference between a sensor value and the actual value - The value of this OID variable should be scaled by - (transferSwitchSensorDecimalDigits + 1). For example, if the value is 50 and - transferSwitchSensorDecimalDigits is 2, then actual value is 0.05. - This parameter does not apply to sensors without numerical reading, - e.g. operational state or switch fault sensors." - ::= { transferSwitchSensorConfigurationEntry 10 } +transferSwitchSensorTolerance OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The tolerance: the maximum difference between measurement and the + actual value. The value of this OID variable should be scaled by + (transferSwitchSensorDecimalDigits + 1). For example, if the value is 50 and + transferSwitchSensorDecimalDigits is 2, then actual value is 0.05. + This parameter does not apply to sensors without numerical reading." + ::= { transferSwitchSensorConfigurationEntry 10 } -transferSwitchSensorMaximum OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The largest possible reading as an unsigned integer. - The value of this OID variable should be scaled by - transferSwitchSensorDecimalDigits. For example, if the value is 1 and - transferSwitchSensorDecimalDigits is 2, then actual value is 0.01. - The value is clamped if the scaled maximum exceeds 4294967295. It - is undefined for sensors which can have negative readings. - This parameter does not apply to sensors without numerical reading, - e.g. operational state or switch fault sensors." - ::= { transferSwitchSensorConfigurationEntry 11 } +transferSwitchSensorMaximum OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The largest possible reading as an unsigned integer. + The value of this OID variable should be scaled by + transferSwitchSensorDecimalDigits. For example, if the value is 1 and + transferSwitchSensorDecimalDigits is 2, then actual value is 0.01. + The value is clamped if the scaled maximum exceeds 4294967295. It + is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { transferSwitchSensorConfigurationEntry 11 } -transferSwitchSensorMinimum OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The smallest possible reading as an unsigned integer. - The value of this OID variable should be scaled by - transferSwitchSensorDecimalDigits. For example, if the value is 1 and - transferSwitchSensorDecimalDigits is 2, then actual value is 0.01. - The value is undefined for sensors which can have negative readings. - This parameter does not apply to sensors without numerical reading, - e.g. operational state or switch fault sensors." - ::= { transferSwitchSensorConfigurationEntry 12 } +transferSwitchSensorMinimum OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The smallest possible reading as an unsigned integer. + The value of this OID variable should be scaled by + transferSwitchSensorDecimalDigits. For example, if the value is 1 and + transferSwitchSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { transferSwitchSensorConfigurationEntry 12 } -transferSwitchSensorHysteresis OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The hysteresis used for deassertions - The value of this OID variable should be scaled by - transferSwitchSensorDecimalDigits. For example, if the value is 1 and - transferSwitchSensorDecimalDigits is 2, then actual value is 0.01. - This parameter does not apply to sensors without numerical reading, - e.g. operational state or switch fault sensors." - ::= { transferSwitchSensorConfigurationEntry 13 } +transferSwitchSensorHysteresis OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The hysteresis used when crossing a threshold towards the normal state. + The value of this OID variable should be scaled by + transferSwitchSensorDecimalDigits. For example, if the value is 1 and + transferSwitchSensorDecimalDigits is 2, then actual value is 0.01. + This parameter does not apply to sensors without numerical reading." + ::= { transferSwitchSensorConfigurationEntry 13 } -transferSwitchSensorStateChangeDelay OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The delay measured in samples before a state is asserted. - If the value is zero, then the state is asserted as soon as - it is detected; if it is non-zero, say n, then the assertion - condition must exist for n+1 consecutive samples before the corresponding - assertion event is reported. - This parameter does not apply to sensors without numerical reading, - e.g. operational state or switch fault sensors." - ::= { transferSwitchSensorConfigurationEntry 14 } +transferSwitchSensorStateChangeDelay OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The delay measured in samples before a state is asserted. + If the value is zero, then the state is asserted as soon as + it is detected; if it is non-zero, say n, then the assertion + condition must exist for n+1 consecutive samples before the + event is reported. + This parameter does not apply to sensors without numerical reading." + ::= { transferSwitchSensorConfigurationEntry 14 } transferSwitchSensorLowerCriticalThreshold OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The lower critical threshold as an unsigned integer. - The value of this OID variable should be scaled by - transferSwitchSensorDecimalDigits. For example, if the value is 1 and - transferSwitchSensorDecimalDigits is 2, then actual value is 0.01. - The value is clamped if the scaled threshold exceeds 4294967295. It - is undefined for sensors which can have negative readings. - This parameter does not apply to sensors without numerical reading, - e.g. operational state or switch fault sensors." - ::= { transferSwitchSensorConfigurationEntry 21 } + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The lower critical threshold as an unsigned integer. + The value of this OID variable should be scaled by + transferSwitchSensorDecimalDigits. For example, if the value is 1 and + transferSwitchSensorDecimalDigits is 2, then actual value is 0.01. + The value is clamped if the scaled threshold exceeds 4294967295. It + is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { transferSwitchSensorConfigurationEntry 21 } transferSwitchSensorLowerWarningThreshold OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The lower warning threshold as an unsigned integer. - The value of this OID variable should be scaled by - transferSwitchSensorDecimalDigits. For example, if the value is 1 and - transferSwitchSensorDecimalDigits is 2, then actual value is 0.01. - The value is clamped if the scaled threshold exceeds 4294967295. It - is undefined for sensors which can have negative readings. - This parameter does not apply to sensors without numerical reading, - e.g. operational state or switch fault sensors." - ::= { transferSwitchSensorConfigurationEntry 22 } + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The lower warning threshold as an unsigned integer. + The value of this OID variable should be scaled by + transferSwitchSensorDecimalDigits. For example, if the value is 1 and + transferSwitchSensorDecimalDigits is 2, then actual value is 0.01. + The value is clamped if the scaled threshold exceeds 4294967295. It + is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { transferSwitchSensorConfigurationEntry 22 } transferSwitchSensorUpperCriticalThreshold OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The upper critical threshold as an unsigned integer. - The value of this OID variable should be scaled by - transferSwitchSensorDecimalDigits. For example, if the value is 1 and - transferSwitchSensorDecimalDigits is 2, then actual value is 0.01. - The value is clamped if the scaled threshold exceeds 4294967295. It - is undefined for sensors which can have negative readings. - This parameter does not apply to sensors without numerical reading, - e.g. operational state or switch fault sensors." - ::= { transferSwitchSensorConfigurationEntry 23 } + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The upper critical threshold as an unsigned integer. + The value of this OID variable should be scaled by + transferSwitchSensorDecimalDigits. For example, if the value is 1 and + transferSwitchSensorDecimalDigits is 2, then actual value is 0.01. + The value is clamped if the scaled threshold exceeds 4294967295. It + is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { transferSwitchSensorConfigurationEntry 23 } transferSwitchSensorUpperWarningThreshold OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The upper warning threshold as an unsigned integer. - The value of this OID variable should be scaled by - transferSwitchSensorDecimalDigits. For example, if the value is 1 and - transferSwitchSensorDecimalDigits is 2, then actual value is 0.01. - The value is clamped if the scaled threshold exceeds 4294967295. It - is undefined for sensors which can have negative readings. - This parameter does not apply to sensors without numerical reading, - e.g. operational state or switch fault sensors." - ::= { transferSwitchSensorConfigurationEntry 24 } + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The upper warning threshold as an unsigned integer. + The value of this OID variable should be scaled by + transferSwitchSensorDecimalDigits. For example, if the value is 1 and + transferSwitchSensorDecimalDigits is 2, then actual value is 0.01. + The value is clamped if the scaled threshold exceeds 4294967295. It + is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { transferSwitchSensorConfigurationEntry 24 } transferSwitchSensorEnabledThresholds OBJECT-TYPE - SYNTAX BITS { - lowerCritical(0), - lowerWarning(1), - upperWarning(2), - upperCritical(3) - } - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "A bit string which indicates which thresholds are enabled. - This parameter does not apply to sensors without numerical reading, - e.g. operational state or switch fault sensors." - ::= { transferSwitchSensorConfigurationEntry 25 } + SYNTAX BITS { lowerCritical(0), + lowerWarning(1), + upperWarning(2), + upperCritical(3) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "A bit string indicating which thresholds are enabled. + This parameter does not apply to sensors without numerical reading." + ::= { transferSwitchSensorConfigurationEntry 25 } -transferSwitchSensorSignedMaximum OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The largest possible reading as a signed integer. - The value of this OID variable should be scaled by - transferSwitchSensorDecimalDigits. For example, if the value is 1 and - transferSwitchSensorDecimalDigits is 2, then actual value is 0.01. - The value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647). - This parameter does not apply to sensors without numerical reading, - e.g. operational state or switch fault sensors." - ::= { transferSwitchSensorConfigurationEntry 26 } +transferSwitchSensorSignedMaximum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The largest possible reading as a signed integer. + The value of this OID variable should be scaled by + transferSwitchSensorDecimalDigits. For example, if the value is 1 and + transferSwitchSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { transferSwitchSensorConfigurationEntry 26 } -transferSwitchSensorSignedMinimum OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The smallest possible reading as a signed integer. - The value of this OID variable should be scaled by - transferSwitchSensorDecimalDigits. For example, if the value is 1 and - transferSwitchSensorDecimalDigits is 2, then actual value is 0.01. - This value determines whether to use the signed or unsigned threshold - and value columns: If the minimum is below zero the sensor can have - negative readings and the signed columns should be used. - This parameter does not apply to sensors without numerical reading, - e.g. operational state or switch fault sensors." - ::= { transferSwitchSensorConfigurationEntry 27 } +transferSwitchSensorSignedMinimum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The smallest possible reading as a signed integer. + The value of this OID variable should be scaled by + transferSwitchSensorDecimalDigits. For example, if the value is 1 and + transferSwitchSensorDecimalDigits is 2, then actual value is 0.01. + This value determines whether to use the signed or unsigned threshold + and value columns: If the minimum is below zero the sensor can have + negative readings and the signed columns should be used. + This parameter does not apply to sensors without numerical reading." + ::= { transferSwitchSensorConfigurationEntry 27 } transferSwitchSensorSignedLowerCriticalThreshold OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The lower critical threshold as a signed integer. - The value of this OID variable should be scaled by - transferSwitchSensorDecimalDigits. For example, if the value is 1 and - transferSwitchSensorDecimalDigits is 2, then actual value is 0.01. - The value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647). - This parameter does not apply to sensors without numerical reading, - e.g. operational state or switch fault sensors." - ::= { transferSwitchSensorConfigurationEntry 28 } + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The lower critical threshold as a signed integer. + The value of this OID variable should be scaled by + transferSwitchSensorDecimalDigits. For example, if the value is 1 and + transferSwitchSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { transferSwitchSensorConfigurationEntry 28 } transferSwitchSensorSignedLowerWarningThreshold OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The lower warning threshold as a signed integer. - The value of this OID variable should be scaled by - transferSwitchSensorDecimalDigits. For example, if the value is 1 and - transferSwitchSensorDecimalDigits is 2, then actual value is 0.01. - The value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647). - This parameter does not apply to sensors without numerical reading, - e.g. operational state or switch fault sensors." - ::= { transferSwitchSensorConfigurationEntry 29 } + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The lower warning threshold as a signed integer. + The value of this OID variable should be scaled by + transferSwitchSensorDecimalDigits. For example, if the value is 1 and + transferSwitchSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { transferSwitchSensorConfigurationEntry 29 } transferSwitchSensorSignedUpperCriticalThreshold OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The upper critical threshold as a signed integer. - The value of this OID variable should be scaled by - transferSwitchSensorDecimalDigits. For example, if the value is 1 and - transferSwitchSensorDecimalDigits is 2, then actual value is 0.01. - The value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647). - This parameter does not apply to sensors without numerical reading, - e.g. operational state or switch fault sensors." - ::= { transferSwitchSensorConfigurationEntry 30 } + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The upper critical threshold as a signed integer. + The value of this OID variable should be scaled by + transferSwitchSensorDecimalDigits. For example, if the value is 1 and + transferSwitchSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { transferSwitchSensorConfigurationEntry 30 } transferSwitchSensorSignedUpperWarningThreshold OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The upper warning threshold as a signed integer. - The value of this OID variable should be scaled by - transferSwitchSensorDecimalDigits. For example, if the value is 1 and - transferSwitchSensorDecimalDigits is 2, then actual value is 0.01. - The value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647). - This parameter does not apply to sensors without numerical reading, - e.g. operational state or switch fault sensors." - ::= { transferSwitchSensorConfigurationEntry 31 } + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The upper warning threshold as a signed integer. + The value of this OID variable should be scaled by + transferSwitchSensorDecimalDigits. For example, if the value is 1 and + transferSwitchSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { transferSwitchSensorConfigurationEntry 31 } +-- powerMeterConfigurationTable: BCM2/PMC power meter and panel information +powerMeterConfigurationTable OBJECT-TYPE + SYNTAX SEQUENCE OF PowerMeterConfigurationEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of power meter and panel configuration entries. + Note: Also see inlet tables for settings and sensor information." + ::= { powerMeter 2 } --- The PeripheralDevicePackageTable table contains information on the peripheral Device Packages connected to the PDU +powerMeterConfigurationEntry OBJECT-TYPE + SYNTAX PowerMeterConfigurationEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing configuration objects for power meters and panels." + INDEX { pduId } + ::= { powerMeterConfigurationTable 1 } +PowerMeterConfigurationEntryStruct ::= SEQUENCE { + powerMeterPhaseCTRating Unsigned32, + powerMeterNeutralCTRating Unsigned32, + powerMeterEarthCTRating Unsigned32, + powerMeterBranchCount Unsigned32, + powerMeterPanelPositions Integer32, + powerMeterPanelLayout PanelLayoutEnumeration, + powerMeterPanelNumbering PanelNumberingEnumeration, + powerMeterType PowerMeterTypeEnumeration + } -peripheralDevicePackageTable OBJECT-TYPE - SYNTAX SEQUENCE OF PeripheralDevicePackageEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A list of entries for the peripheral Device Packages connected to each PDU. The number of - entries is given by the value of peripheralDevicePackagesCount." - ::= { externalSensors 5} +powerMeterPhaseCTRating OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The rating of the phase CT in Amps, or 0 if no CT is present. + At present, read-only access; + see MIN-ACCESS in MODULE-COMPLIANCE ModulecomplianceRev2" + ::= { powerMeterConfigurationEntry 2 } -peripheralDevicePackageEntry OBJECT-TYPE - SYNTAX PeripheralDevicePackageEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "An entry containing objects for a controller." - INDEX { pduId, peripheralDevicePackageId } - ::= { peripheralDevicePackageTable 1 } +powerMeterNeutralCTRating OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The rating of the neutral CT in Amps, or 0 if no CT is present. + At present, read-only access; + see MIN-ACCESS in MODULE-COMPLIANCE ModulecomplianceRev2" + ::= { powerMeterConfigurationEntry 3 } -PeripheralDevicePackageEntryStruct ::= SEQUENCE { - peripheralDevicePackageId Integer32, - peripheralDevicePackageSerialNumber DisplayString, - peripheralDevicePackageModel DisplayString, - peripheralDevicePackageFirmwareVersion DisplayString, - peripheralDevicePackageMinFirmwareVersion DisplayString, - peripheralDevicePackageFirmwareTimeStamp Unsigned32, - peripheralDevicePackagePosition DisplayString, - peripheralDevicePackageState DisplayString - } +powerMeterEarthCTRating OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The rating of the earth CT in Amps, or 0 if no CT is present. + At present, read-only access; + see MIN-ACCESS in MODULE-COMPLIANCE ModulecomplianceRev2" + ::= { powerMeterConfigurationEntry 4 } +powerMeterBranchCount OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The maximum number of circuits supported by the panel. + This can be used to distinguish between panels (>0) and power meters (0). + See circuitCount for the number of currently defined circuits." + ::= { powerMeterConfigurationEntry 5 } +powerMeterPanelPositions OBJECT-TYPE + SYNTAX Integer32(1..256) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of circuit positions in the panel. + Its value is specified by the user when configuring a panel" + ::= { powerMeterConfigurationEntry 6 } +powerMeterPanelLayout OBJECT-TYPE + SYNTAX PanelLayoutEnumeration + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The panel circuit position layout: one or two columns. + This is valid only for panels, the value is -1 for power meters." + ::= { powerMeterConfigurationEntry 7 } -peripheralDevicePackageId OBJECT-TYPE - SYNTAX Integer32(1..256) - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A unique value for each peripheral device package." - ::= { peripheralDevicePackageEntry 1 } +powerMeterPanelNumbering OBJECT-TYPE + SYNTAX PanelNumberingEnumeration + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The panel circuit position numbering scheme: odd/even or sequential. + This is valid only for panels, the value is -1 for power meters." + ::= { powerMeterConfigurationEntry 8 } +powerMeterType OBJECT-TYPE + SYNTAX PowerMeterTypeEnumeration + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The power meter type: 3-phase, single-phase or split-phase." + ::= { powerMeterConfigurationEntry 9 } -peripheralDevicePackageSerialNumber OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The peripheral device package serial number." - ::= { peripheralDevicePackageEntry 3 } +-- circuitConfigurationTable: BCM2/PMC branch circuit information -peripheralDevicePackageModel OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The peripheral device package model. - Examples are DX-D2C6, DPX2-T1, DPX2-T1H1, DPX2-T2H1, DPX2-T3H1" - ::= { peripheralDevicePackageEntry 4 } +circuitConfigurationTable OBJECT-TYPE + SYNTAX SEQUENCE OF CircuitConfigurationEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of circuit configuration entries. The number of + entries is given by the value of panelCircuitPositionCount." + ::= { circuit 2 } +circuitConfigurationEntry OBJECT-TYPE + SYNTAX CircuitConfigurationEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing configuration objects for the circuit." + INDEX { pduId, circuitId } + ::= { circuitConfigurationTable 1 } +CircuitConfigurationEntryStruct ::= SEQUENCE { + circuitId Integer32, + circuitPoleCount Integer32, + circuitName DisplayString, + circuitType CircuitTypeEnumeration, + circuitRatedCurrent Unsigned32, + circuitCTRating Unsigned32, + circuitCapabilities BITS, + circuitPoleCapabilities BITS, + circuitPowerSource RowPointer + } -peripheralDevicePackageFirmwareVersion OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The peripheral device package firmware version." - ::= { peripheralDevicePackageEntry 5 } +circuitId OBJECT-TYPE + SYNTAX Integer32(1..1024) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A unique value for each circuit. Its value is the smallest panel + position occupied by the circuit." + ::= { circuitConfigurationEntry 1 } +circuitPoleCount OBJECT-TYPE + SYNTAX Integer32(1..256) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of panel positions occupied by the circuit." + ::= { circuitConfigurationEntry 2 } -peripheralDevicePackageMinFirmwareVersion OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The peripheral device package minimum firmware version. - This field may be empty. If it is not empty, then it shall not be possible - to downgrade the peripheral device firmware to a - version < minimum firmware version number." - ::= { peripheralDevicePackageEntry 6 } +circuitName OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The user-defined name for the circuit. + At present, read-only access; + see MIN-ACCESS in MODULE-COMPLIANCE ModulecomplianceRev2" + ::= { circuitConfigurationEntry 3 } +circuitType OBJECT-TYPE + SYNTAX CircuitTypeEnumeration + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The circuit type: line-line, line-neutral, line-line-neutral or 3-phase" + ::= { circuitConfigurationEntry 4 } -peripheralDevicePackageFirmwareTimeStamp OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The time when the peripheralDevicePackage firmware was updated in UNIX(epoch)time. - It is measured in seconds relative to January 1, 1970 (midnight UTC/GMT), - i.e a value of 0 indicates January 1, 1970 (midnight UTC/GMT)." - ::= { peripheralDevicePackageEntry 7 } +circuitRatedCurrent OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The rating of the breaker for the circuit in Amps. + At present, read-only access; + see MIN-ACCESS in MODULE-COMPLIANCE ModulecomplianceRev2" + ::= { circuitConfigurationEntry 5 } + +circuitCTRating OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The rating of the CTs metering this circuit in Amps. + At present, read-only access; + see MIN-ACCESS in MODULE-COMPLIANCE ModulecomplianceRev2" + ::= { circuitConfigurationEntry 6 } + +circuitCapabilities OBJECT-TYPE + SYNTAX BITS { rmsCurrent(0), + peakCurrent(1), + unbalancedCurrent(2), + rmsVoltage(3), + activePower(4), + apparentPower(5), + powerFactor(6), + activeEnergy(7), + apparentEnergy(8), + surgeProtectorStatus(21), + frequency(22), + phaseAngle(23), + residualCurrent(25), + rcmState(26), + reactivePower(28), + powerQuality(31), + displacementPowerFactor(34) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A bit string indicating which sensors are available for the circuit." + ::= { circuitConfigurationEntry 7 } + +circuitPoleCapabilities OBJECT-TYPE + SYNTAX BITS { rmsCurrent(0), + peakCurrent(1), + rmsVoltage(3), + activePower(4), + apparentPower(5), + powerFactor(6), + activeEnergy(7), + apparentEnergy(8), + phaseAngle(23), + rmsVoltageLN(24), + reactivePower(28), + displacementPowerFactor(34) } + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "A bit string indicating which sensors are available for each circuit pole." + ::= { circuitConfigurationEntry 8 } + +circuitPowerSource OBJECT-TYPE + SYNTAX RowPointer + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "This object allows discovery of how the circuit is wired. It indicates the + circuit's power source, typically an inlet. + + It contains the OID of an inletLabel in the inletConfigurationTable. + The indices of the OID can then be used to reference other objects in the + inlet and power meter tables." + ::= { circuitConfigurationEntry 9 } + +-- circuitPoleConfigurationTable: BCM2/PMC branch circuit pole information + +circuitPoleConfigurationTable OBJECT-TYPE + SYNTAX SEQUENCE OF CircuitPoleConfigurationEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of branch circuit pole configuration entries. The number of + entries is given by the value of circuitPoleCount for the circuit." + ::= { circuit 3 } + +circuitPoleConfigurationEntry OBJECT-TYPE + SYNTAX CircuitPoleConfigurationEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing configuration objects for the circuit poles." + INDEX { pduId, circuitId, circuitPoleId } + ::= { circuitPoleConfigurationTable 1 } + +CircuitPoleConfigurationEntryStruct ::= SEQUENCE { + circuitPoleId Integer32, + circuitPolePanelPosition Integer32, + circuitPoleCTNumber Integer32, + circuitPolePhase PhaseEnumeration + } + +circuitPoleId OBJECT-TYPE + SYNTAX Integer32(1..256) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A unique value for each circuit pole. Its value + ranges between 1 and the value of circuitPoleCount." + ::= { circuitPoleConfigurationEntry 1 } + +circuitPolePanelPosition OBJECT-TYPE + SYNTAX Integer32(1..256) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The panel position for this pole." + ::= { circuitPoleConfigurationEntry 2 } + +circuitPoleCTNumber OBJECT-TYPE + SYNTAX Integer32(0..256) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The CT number for this circuit pole, or 0 if no CT is present. + At present, read-only access; + see MIN-ACCESS in MODULE-COMPLIANCE ModulecomplianceRev2" + ::= { circuitPoleConfigurationEntry 3 } + +circuitPolePhase OBJECT-TYPE + SYNTAX PhaseEnumeration + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The phase for this circuit pole. + At present, read-only access; + see MIN-ACCESS in MODULE-COMPLIANCE ModulecomplianceRev2" + ::= { circuitPoleConfigurationEntry 4 } + +-- circuitSensorConfigurationTable: information and settings for BCM2/PMC circuit sensors + +circuitSensorConfigurationTable OBJECT-TYPE + SYNTAX SEQUENCE OF CircuitSensorConfigurationEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of configuration entries for branch circuit sensor." + ::= { circuit 4 } + +circuitSensorConfigurationEntry OBJECT-TYPE + SYNTAX CircuitSensorConfigurationEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing objects for configuring a branch circuit sensor." + INDEX { pduId, circuitId, sensorType } + ::= { circuitSensorConfigurationTable 1 } + +CircuitSensorConfigurationEntryStruct ::= SEQUENCE { + circuitSensorLogAvailable TruthValue, + circuitSensorUnits SensorUnitsEnumeration, + circuitSensorDecimalDigits Unsigned32, + circuitSensorResolution Unsigned32, + circuitSensorMaximum Unsigned32, + circuitSensorMinimum Unsigned32, + circuitSensorHysteresis Unsigned32, + circuitSensorStateChangeDelay Unsigned32, + circuitSensorLowerCriticalThreshold Unsigned32, + circuitSensorLowerWarningThreshold Unsigned32, + circuitSensorUpperCriticalThreshold Unsigned32, + circuitSensorUpperWarningThreshold Unsigned32, + circuitSensorEnabledThresholds BITS, + circuitSensorSignedMaximum Integer32, + circuitSensorSignedMinimum Integer32, + circuitSensorSignedLowerCriticalThreshold Integer32, + circuitSensorSignedLowerWarningThreshold Integer32, + circuitSensorSignedUpperCriticalThreshold Integer32, + circuitSensorSignedUpperWarningThreshold Integer32 + } + +circuitSensorLogAvailable OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is data logging enabled for the sensor?" + ::= { circuitSensorConfigurationEntry 4 } + +circuitSensorUnits OBJECT-TYPE + SYNTAX SensorUnitsEnumeration + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The unit in which the sensor reading is reported. + This parameter does not apply to sensors without numerical reading." + ::= { circuitSensorConfigurationEntry 6 } + +circuitSensorDecimalDigits OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of digits displayed to the right of the decimal point. + This parameter does not apply to sensors without numerical reading." + ::= { circuitSensorConfigurationEntry 7 } + +circuitSensorResolution OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The resolution: the minimum difference between any two measured values + The value of this OID variable should be scaled by + inletSensorDecimalDigits. For example, if the value is 1 and + inletSensorDecimalDigits is 2, then actual value is 0.01. + This parameter does not apply to sensors without numerical reading." + ::= { circuitSensorConfigurationEntry 9 } + +circuitSensorMaximum OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The largest possible reading as an unsigned integer. + The value of this OID variable should be scaled by + inletSensorDecimalDigits. For example, if the value is 1 and + inletSensorDecimalDigits is 2, then actual value is 0.01. + The value is clamped if the scaled maximum exceeds 4294967295. It + is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { circuitSensorConfigurationEntry 11 } + +circuitSensorMinimum OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The smallest possible reading as an unsigned integer. + The value of this OID variable should be scaled by + inletSensorDecimalDigits. For example, if the value is 1 and + inletSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { circuitSensorConfigurationEntry 12 } + +circuitSensorHysteresis OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The hysteresis used when crossing a threshold towards the normal state. + The value of this OID variable should be scaled by + inletSensorDecimalDigits. For example, if the value is 1 and + inletSensorDecimalDigits is 2, then actual value is 0.01. + This parameter does not apply to sensors without numerical reading." + ::= { circuitSensorConfigurationEntry 13 } + +circuitSensorStateChangeDelay OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The delay measured in samples before a state is asserted. + If the value is zero, then the state is asserted as soon as + it is detected; if it is non-zero, say n, then the assertion + condition must exist for n+1 consecutive samples before the + event is reported. + This parameter does not apply to sensors without numerical reading." + ::= { circuitSensorConfigurationEntry 14 } + +circuitSensorLowerCriticalThreshold OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The lower critical threshold as an unsigned integer. + The value of this OID variable should be scaled by + inletSensorDecimalDigits. For example, if the value is 1 and + inletSensorDecimalDigits is 2, then actual value is 0.01. + The value is clamped if the scaled threshold exceeds 4294967295. It + is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { circuitSensorConfigurationEntry 21 } + +circuitSensorLowerWarningThreshold OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The lower warning threshold as an unsigned integer. + The value of this OID variable should be scaled by + inletSensorDecimalDigits. For example, if the value is 1 and + inletSensorDecimalDigits is 2, then actual value is 0.01. + The value is clamped if the scaled threshold exceeds 4294967295. It + is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { circuitSensorConfigurationEntry 22 } + +circuitSensorUpperCriticalThreshold OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The upper critical threshold as an unsigned integer. + The value of this OID variable should be scaled by + inletSensorDecimalDigits. For example, if the value is 1 and + inletSensorDecimalDigits is 2, then actual value is 0.01. + The value is clamped if the scaled threshold exceeds 4294967295. It + is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { circuitSensorConfigurationEntry 23 } + +circuitSensorUpperWarningThreshold OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The upper warning threshold as an unsigned integer. + The value of this OID variable should be scaled by + inletSensorDecimalDigits. For example, if the value is 1 and + inletSensorDecimalDigits is 2, then actual value is 0.01. + The value is clamped if the scaled threshold exceeds 4294967295. It + is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { circuitSensorConfigurationEntry 24 } + +circuitSensorEnabledThresholds OBJECT-TYPE + SYNTAX BITS { lowerCritical(0), + lowerWarning(1), + upperWarning(2), + upperCritical(3) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "A bit string indicating which thresholds are enabled. + This parameter does not apply to sensors without numerical reading." + ::= { circuitSensorConfigurationEntry 25 } + +circuitSensorSignedMaximum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The largest possible reading as a signed integer. + The value of this OID variable should be scaled by + inletSensorDecimalDigits. For example, if the value is 1 and + inletSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { circuitSensorConfigurationEntry 26 } + +circuitSensorSignedMinimum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The smallest possible reading as a signed integer. + The value of this OID variable should be scaled by + inletSensorDecimalDigits. For example, if the value is 1 and + inletSensorDecimalDigits is 2, then actual value is 0.01. + This value determines whether to use the signed or unsigned threshold + and value columns: If the minimum is below zero the sensor can have + negative readings and the signed columns should be used. + This parameter does not apply to sensors without numerical reading." + ::= { circuitSensorConfigurationEntry 27 } + +circuitSensorSignedLowerCriticalThreshold OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The lower critical threshold as a signed integer. + The value of this OID variable should be scaled by + inletSensorDecimalDigits. For example, if the value is 1 and + inletSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { circuitSensorConfigurationEntry 28 } + +circuitSensorSignedLowerWarningThreshold OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The lower warning threshold as a signed integer. + The value of this OID variable should be scaled by + inletSensorDecimalDigits. For example, if the value is 1 and + inletSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { circuitSensorConfigurationEntry 29 } + +circuitSensorSignedUpperCriticalThreshold OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The upper critical threshold as a signed integer. + The value of this OID variable should be scaled by + inletSensorDecimalDigits. For example, if the value is 1 and + inletSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { circuitSensorConfigurationEntry 30 } + +circuitSensorSignedUpperWarningThreshold OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The upper warning threshold as a signed integer. + The value of this OID variable should be scaled by + inletSensorDecimalDigits. For example, if the value is 1 and + inletSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { circuitSensorConfigurationEntry 31 } + +-- circuitPoleSensorConfigurationTable: information and settings for BCM2/PMC circuit pole sensors + +circuitPoleSensorConfigurationTable OBJECT-TYPE + SYNTAX SEQUENCE OF CircuitPoleSensorConfigurationEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of configuration entries for a circuit's pole sensors." + ::= { circuit 6 } + +circuitPoleSensorConfigurationEntry OBJECT-TYPE + SYNTAX CircuitPoleSensorConfigurationEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing objects for configuring a circuit pole sensor." + INDEX { pduId, circuitId, circuitPoleId, sensorType } + ::= { circuitPoleSensorConfigurationTable 1 } + +CircuitPoleSensorConfigurationEntryStruct ::= SEQUENCE { + circuitPoleSensorLogAvailable TruthValue, + circuitPoleSensorUnits SensorUnitsEnumeration, + circuitPoleSensorDecimalDigits Unsigned32, + circuitPoleSensorResolution Unsigned32, + circuitPoleSensorMaximum Unsigned32, + circuitPoleSensorMinimum Unsigned32, + circuitPoleSensorHysteresis Unsigned32, + circuitPoleSensorStateChangeDelay Unsigned32, + circuitPoleSensorLowerCriticalThreshold Unsigned32, + circuitPoleSensorLowerWarningThreshold Unsigned32, + circuitPoleSensorUpperCriticalThreshold Unsigned32, + circuitPoleSensorUpperWarningThreshold Unsigned32, + circuitPoleSensorEnabledThresholds BITS, + circuitPoleSensorSignedMaximum Integer32, + circuitPoleSensorSignedMinimum Integer32, + circuitPoleSensorSignedLowerCriticalThreshold Integer32, + circuitPoleSensorSignedLowerWarningThreshold Integer32, + circuitPoleSensorSignedUpperCriticalThreshold Integer32, + circuitPoleSensorSignedUpperWarningThreshold Integer32 + } + +circuitPoleSensorLogAvailable OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Is data logging enabled for the sensor?" + ::= { circuitPoleSensorConfigurationEntry 4 } + +circuitPoleSensorUnits OBJECT-TYPE + SYNTAX SensorUnitsEnumeration + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The unit in which the sensor reading is reported. + This parameter does not apply to sensors without numerical reading." + ::= { circuitPoleSensorConfigurationEntry 6 } + +circuitPoleSensorDecimalDigits OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The number of digits displayed to the right of the decimal point. + This parameter does not apply to sensors without numerical reading." + ::= { circuitPoleSensorConfigurationEntry 7 } + +circuitPoleSensorResolution OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The resolution: the minimum difference between any two measured values + The value of this OID variable should be scaled by + inletPoleSensorDecimalDigits. For example, if the value is 1 and + inletPoleSensorDecimalDigits is 2, then actual value is 0.01. + This parameter does not apply to sensors without numerical reading." + ::= { circuitPoleSensorConfigurationEntry 9 } + +circuitPoleSensorMaximum OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The largest possible reading as an unsigned integer. + The value of this OID variable should be scaled by + inletPoleSensorDecimalDigits. For example, if the value is 1 and + inletPoleSensorDecimalDigits is 2, then actual value is 0.01. + The value is clamped if the scaled maximum exceeds 4294967295. It + is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { circuitPoleSensorConfigurationEntry 11 } + +circuitPoleSensorMinimum OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The smallest possible reading as an unsigned integer. + The value of this OID variable should be scaled by + inletPoleSensorDecimalDigits. For example, if the value is 1 and + inletPoleSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { circuitPoleSensorConfigurationEntry 12 } + +circuitPoleSensorHysteresis OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The hysteresis used when crossing a threshold towards the normal state. + The value of this OID variable should be scaled by + inletPoleSensorDecimalDigits. For example, if the value is 1 and + inletPoleSensorDecimalDigits is 2, then actual value is 0.01. + This parameter does not apply to sensors without numerical reading." + ::= { circuitPoleSensorConfigurationEntry 13 } + +circuitPoleSensorStateChangeDelay OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The delay measured in samples before a state is asserted. + If the value is zero, then the state is asserted as soon as + it is detected; if it is non-zero, say n, then the assertion + condition must exist for n+1 consecutive samples before the + event is reported. + This parameter does not apply to sensors without numerical reading." + ::= { circuitPoleSensorConfigurationEntry 14 } + +circuitPoleSensorLowerCriticalThreshold OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The lower critical threshold as an unsigned integer. + The value of this OID variable should be scaled by + inletPoleSensorDecimalDigits. For example, if the value is 1 and + inletPoleSensorDecimalDigits is 2, then actual value is 0.01. + The value is clamped if the scaled threshold exceeds 4294967295. It + is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { circuitPoleSensorConfigurationEntry 21 } + +circuitPoleSensorLowerWarningThreshold OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The lower warning threshold as an unsigned integer. + The value of this OID variable should be scaled by + inletPoleSensorDecimalDigits. For example, if the value is 1 and + inletPoleSensorDecimalDigits is 2, then actual value is 0.01. + The value is clamped if the scaled threshold exceeds 4294967295. It + is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { circuitPoleSensorConfigurationEntry 22 } + +circuitPoleSensorUpperCriticalThreshold OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The upper critical threshold as an unsigned integer. + The value of this OID variable should be scaled by + inletPoleSensorDecimalDigits. For example, if the value is 1 and + inletPoleSensorDecimalDigits is 2, then actual value is 0.01. + The value is clamped if the scaled threshold exceeds 4294967295. It + is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { circuitPoleSensorConfigurationEntry 23 } + +circuitPoleSensorUpperWarningThreshold OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The upper warning threshold as an unsigned integer. + The value of this OID variable should be scaled by + inletPoleSensorDecimalDigits. For example, if the value is 1 and + inletPoleSensorDecimalDigits is 2, then actual value is 0.01. + The value is clamped if the scaled threshold exceeds 4294967295. It + is undefined for sensors which can have negative readings. + This parameter does not apply to sensors without numerical reading." + ::= { circuitPoleSensorConfigurationEntry 24 } + +circuitPoleSensorEnabledThresholds OBJECT-TYPE + SYNTAX BITS { lowerCritical(0), + lowerWarning(1), + upperWarning(2), + upperCritical(3) } + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "A bit string indicating which thresholds are enabled. + This parameter does not apply to sensors without numerical reading." + ::= { circuitPoleSensorConfigurationEntry 25 } + +circuitPoleSensorSignedMaximum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The largest possible reading as a signed integer. + The value of this OID variable should be scaled by + inletPoleSensorDecimalDigits. For example, if the value is 1 and + inletPoleSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { circuitPoleSensorConfigurationEntry 26 } + +circuitPoleSensorSignedMinimum OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The smallest possible reading as a signed integer. + The value of this OID variable should be scaled by + inletPoleSensorDecimalDigits. For example, if the value is 1 and + inletPoleSensorDecimalDigits is 2, then actual value is 0.01. + This value determines whether to use the signed or unsigned threshold + and value columns: If the minimum is below zero the sensor can have + negative readings and the signed columns should be used. + This parameter does not apply to sensors without numerical reading." + ::= { circuitPoleSensorConfigurationEntry 27 } + +circuitPoleSensorSignedLowerCriticalThreshold OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The lower critical threshold as a signed integer. + The value of this OID variable should be scaled by + inletPoleSensorDecimalDigits. For example, if the value is 1 and + inletPoleSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { circuitPoleSensorConfigurationEntry 28 } + +circuitPoleSensorSignedLowerWarningThreshold OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The lower warning threshold as a signed integer. + The value of this OID variable should be scaled by + inletPoleSensorDecimalDigits. For example, if the value is 1 and + inletPoleSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { circuitPoleSensorConfigurationEntry 29 } + +circuitPoleSensorSignedUpperCriticalThreshold OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The upper critical threshold as a signed integer. + The value of this OID variable should be scaled by + inletPoleSensorDecimalDigits. For example, if the value is 1 and + inletPoleSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { circuitPoleSensorConfigurationEntry 30 } + +circuitPoleSensorSignedUpperWarningThreshold OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The upper warning threshold as a signed integer. + The value of this OID variable should be scaled by + inletPoleSensorDecimalDigits. For example, if the value is 1 and + inletPoleSensorDecimalDigits is 2, then actual value is 0.01. + The value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { circuitPoleSensorConfigurationEntry 31 } + +-- peripheralDevicePackageTable: peripheral device package information + +peripheralDevicePackageTable OBJECT-TYPE + SYNTAX SEQUENCE OF PeripheralDevicePackageEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of entries for the peripheral device packages connected to a PDU. + The number of entries is given by the value of peripheralDevicePackagesCount. + A peripheral device package contains one or more sensors or actuators in a + single enclosure." + ::= { externalSensors 5 } + +peripheralDevicePackageEntry OBJECT-TYPE + SYNTAX PeripheralDevicePackageEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing objects for a peripheral device package." + INDEX { pduId, peripheralDevicePackageId } + ::= { peripheralDevicePackageTable 1 } + +PeripheralDevicePackageEntryStruct ::= SEQUENCE { + peripheralDevicePackageId Integer32, + peripheralDevicePackageSerialNumber DisplayString, + peripheralDevicePackageModel DisplayString, + peripheralDevicePackageFirmwareVersion DisplayString, + peripheralDevicePackageMinFirmwareVersion DisplayString, + peripheralDevicePackageFirmwareTimeStamp Unsigned32, + peripheralDevicePackagePosition DisplayString, + peripheralDevicePackageState DisplayString + } + +peripheralDevicePackageId OBJECT-TYPE + SYNTAX Integer32(1..256) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A unique value for each peripheral device package." + ::= { peripheralDevicePackageEntry 1 } + +peripheralDevicePackageSerialNumber OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The peripheral device package serial number." + ::= { peripheralDevicePackageEntry 3 } + +peripheralDevicePackageModel OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The peripheral device package model. + Examples are DX-D2C6, DPX2-T1, DPX2-T1H1, DPX2-T2H1, DPX2-T3H1" + ::= { peripheralDevicePackageEntry 4 } + +peripheralDevicePackageFirmwareVersion OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The peripheral device package firmware version." + ::= { peripheralDevicePackageEntry 5 } + +peripheralDevicePackageMinFirmwareVersion OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The peripheral device package minimum firmware version. + This field may be empty. If it is not empty, then it shall not be possible + to downgrade the peripheral device firmware to an older version." + ::= { peripheralDevicePackageEntry 6 } + +peripheralDevicePackageFirmwareTimeStamp OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time when the peripheral device package firmware was last updated. + It is measured in seconds since January 1, 1970 (midnight UTC/GMT)." + ::= { peripheralDevicePackageEntry 7 } peripheralDevicePackagePosition OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The position of the package. - The format is a semicolon separated list of Keyword:value pairs - - Keyword1:Value1;Keyword2:value2;... - Keyword can be one of the following: - ONBOARD,DEVICE-1WIREPORT;HUBPORT,CHAIN-POSITION - Examples - 1) Onboard Sensor - ONBOARD:CC1 - 2) Old sensor connected to device 1-wire port - DEVICE-1WIREPORT:2 - 3) Old sensor connected to hub port - DEVICE-1WIREPORT:2;HUBPORT:3 - 4) New style sensor connected to device 1-wire port - DEVICE-1WIREPORT:2;CHAIN-POSITION:3 - 5) Old style sensor connected to end of new style sensor chain - DEVICE-1WIREPORT:2;CHAIN-POSITION:7 - " - ::= { peripheralDevicePackageEntry 8 } + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The position of the package in the bus topology. + The format is a semicolon separated list of Keyword:value pairs. + Keyword can be one of the following: + ONBOARD, DEVICE-1WIREPORT, HUBPORT, CHAIN-POSITION + + Examples: + 1) Onboard Sensor + ONBOARD:CC1 + 2) Old sensor connected to device 1-wire port + DEVICE-1WIREPORT:2 + 3) New-style sensor connected to device 1-wire port + DEVICE-1WIREPORT:2;CHAIN-POSITION:3 + 4) New-style sensor connected to hub port 3 + DEVICE-1WIREPORT:2;CHAIN-POSITION:1;HUBPORT:3;CHAIN-POSITION:1 + 5) Old-style sensor connected to end of new-style sensor chain + DEVICE-1WIREPORT:2;" + ::= { peripheralDevicePackageEntry 8 } peripheralDevicePackageState OBJECT-TYPE - SYNTAX DisplayString - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The state of the package." - ::= { peripheralDevicePackageEntry 9 } + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The state of the package." + ::= { peripheralDevicePackageEntry 9 } +-- sensor data log tables --- the log table +logIndexTable OBJECT-TYPE + SYNTAX SEQUENCE OF LogIndexEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A table containing current indices for the data log buffer." + ::= { logUnit 1 } --- The logIndexTable - -logIndexTable OBJECT-TYPE - SYNTAX SEQUENCE OF LogIndexEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A table of log entries." - ::= { logUnit 1 } - -logIndexEntry OBJECT-TYPE - SYNTAX LogIndexEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "An entry in the log containing sensor data." - INDEX { pduId } - ::= { logIndexTable 1 } +logIndexEntry OBJECT-TYPE + SYNTAX LogIndexEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing the current indices for a PDU's data log buffer." + INDEX { pduId } + ::= { logIndexTable 1 } LogIndexEntryStruct ::= SEQUENCE { - oldestLogID Integer32, - newestLogID Integer32 - } + oldestLogID Integer32, + newestLogID Integer32 + } +oldestLogID OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The index of the oldest data in the buffer for this PDU." + ::= { logIndexEntry 2 } +newestLogID OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The index of the newest data in the buffer for this PDU." + ::= { logIndexEntry 3 } +-- logTimeStampTable: timestamp information for each data log entry -oldestLogID OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The index of the oldest data in the buffer for this PDU." - ::= { logIndexEntry 2 } +logTimeStampTable OBJECT-TYPE + SYNTAX SEQUENCE OF LogTimeStampEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of entries containing the timestamps of the entries in the log." + ::= { logUnit 2 } -newestLogID OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The index of the newest data in the buffer for this PDU." - ::= { logIndexEntry 3 } +logTimeStampEntry OBJECT-TYPE + SYNTAX LogTimeStampEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing the timestamp for log entries." + INDEX { pduId, logIndex } + ::= { logTimeStampTable 1 } +LogTimeStampEntryStruct ::= SEQUENCE { + logIndex Integer32, + logTimeStamp Unsigned32 + } +logIndex OBJECT-TYPE + SYNTAX Integer32(1..256) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A unique value for each entry in the log. Its value + ranges between 1 and the value of logSize." + ::= { logTimeStampEntry 1 } --- The logTimeStampTable +logTimeStamp OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The time when the data was collected. It is measured in seconds since + January 1, 1970 (midnight UTC/GMT)." + ::= { logTimeStampEntry 2 } -logTimeStampTable OBJECT-TYPE - SYNTAX SEQUENCE OF LogTimeStampEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A list of entries containing the timestamps of the entries in the log." - ::= { logUnit 2 } +-- unitSensorLogTable: unit-level sensor log data -logTimeStampEntry OBJECT-TYPE - SYNTAX LogTimeStampEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "An entry containing the timestamp for log entries." - INDEX { pduId, logIndex } - ::= { logTimeStampTable 1 } +unitSensorLogTable OBJECT-TYPE + SYNTAX SEQUENCE OF UnitSensorLogEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of unit sensor entries in the log." + ::= { logUnit 3 } -LogTimeStampEntryStruct ::= SEQUENCE {logIndex Integer32, - logTimeStamp Unsigned32 - } - -logIndex OBJECT-TYPE - SYNTAX Integer32(1..256) - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A unique value for each entry in the log. Its value - ranges between 1 and the value of logSize." - ::= { logTimeStampEntry 1 } - - -logTimeStamp OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The time when the data was collected. It is measured in seconds relative to - January 1, 1970 (midnight UTC/GMT), i.e a value of 0 indicates - January 1, 1970 (midnight UTC/GMT)." - ::= { logTimeStampEntry 2 } - - - - --- The unitSensorLogTable - -unitSensorLogTable OBJECT-TYPE - SYNTAX SEQUENCE OF UnitSensorLogEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A list of unit sensor entries in the log." - ::= { logUnit 3 } - -unitSensorLogEntry OBJECT-TYPE - SYNTAX UnitSensorLogEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "An entry containing log objects for an unit sensor." - INDEX { pduId, sensorType, logIndex } - ::= { unitSensorLogTable 1 } +unitSensorLogEntry OBJECT-TYPE + SYNTAX UnitSensorLogEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing log objects for a unit sensor." + INDEX { pduId, sensorType, logIndex } + ::= { unitSensorLogTable 1 } UnitSensorLogEntryStruct ::= SEQUENCE { - logUnitSensorDataAvailable TruthValue, - logUnitSensorState SensorStateEnumeration, - logUnitSensorAvgValue Unsigned32, - logUnitSensorMaxValue Unsigned32, - logUnitSensorMinValue Unsigned32, - logUnitSensorSignedAvgValue Integer32, - logUnitSensorSignedMaxValue Integer32, - logUnitSensorSignedMinValue Integer32 - } + logUnitSensorDataAvailable TruthValue, + logUnitSensorState SensorStateEnumeration, + logUnitSensorAvgValue Unsigned32, + logUnitSensorMaxValue Unsigned32, + logUnitSensorMinValue Unsigned32, + logUnitSensorSignedAvgValue Integer32, + logUnitSensorSignedMaxValue Integer32, + logUnitSensorSignedMinValue Integer32 + } -logUnitSensorDataAvailable OBJECT-TYPE - SYNTAX TruthValue - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "Is data available for this sensor during this measurement period?" - ::= { unitSensorLogEntry 2 } +logUnitSensorDataAvailable OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Is data available for this sensor during this measurement period?" + ::= { unitSensorLogEntry 2 } -logUnitSensorState OBJECT-TYPE - SYNTAX SensorStateEnumeration - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The sensor state." - ::= { unitSensorLogEntry 3 } +logUnitSensorState OBJECT-TYPE + SYNTAX SensorStateEnumeration + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The most critical sensor state during this measurement period." + ::= { unitSensorLogEntry 3 } -logUnitSensorAvgValue OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The average sensor reading for the log period as an unsigned integer. - The value of this OID variable should be scaled by - unitSensorDecimalDigits. For example, if the value is 1 and - unitSensorDecimalDigits is 2, then actual value is 0.01. - This value will wrap around if the scaled sensor reading exceeds - 4294967295. It is undefined for sensors which can have negative - readings." - ::= { unitSensorLogEntry 4 } +logUnitSensorAvgValue OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The average sensor reading for the log period as an unsigned integer. + The value of this OID variable should be scaled by + unitSensorDecimalDigits. For example, if the value is 1 and + unitSensorDecimalDigits is 2, then actual value is 0.01. + This value will wrap around if the scaled sensor reading exceeds + 4294967295. It is undefined for sensors which can have negative + readings. + This object does not apply to sensors without numerical reading." + ::= { unitSensorLogEntry 4 } -logUnitSensorMaxValue OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The maximum sensor reading for the log period as an unsigned integer. - The value of this OID variable should be scaled by - unitSensorDecimalDigits. For example, if the value is 1 and - unitSensorDecimalDigits is 2, then actual value is 0.01. - This value will wrap around if the scaled sensor reading exceeds - 4294967295. It is undefined for sensors which can have negative - readings." - ::= { unitSensorLogEntry 5 } +logUnitSensorMaxValue OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The maximum sensor reading for the log period as an unsigned integer. + The value of this OID variable should be scaled by + unitSensorDecimalDigits. For example, if the value is 1 and + unitSensorDecimalDigits is 2, then actual value is 0.01. + This value will wrap around if the scaled sensor reading exceeds + 4294967295. It is undefined for sensors which can have negative + readings. + This object does not apply to sensors without numerical reading." + ::= { unitSensorLogEntry 5 } -logUnitSensorMinValue OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The minimum sensor reading for the log period as an unsigned integer. - The value of this OID variable should be scaled by - unitSensorDecimalDigits. For example, if the value is 1 and - unitSensorDecimalDigits is 2, then actual value is 0.01. - This value will wrap around if the scaled sensor reading exceeds - 4294967295. It is undefined for sensors which can have negative - readings." - ::= { unitSensorLogEntry 6 } +logUnitSensorMinValue OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The minimum sensor reading for the log period as an unsigned integer. + The value of this OID variable should be scaled by + unitSensorDecimalDigits. For example, if the value is 1 and + unitSensorDecimalDigits is 2, then actual value is 0.01. + This value will wrap around if the scaled sensor reading exceeds + 4294967295. It is undefined for sensors which can have negative + readings. + This object does not apply to sensors without numerical reading." + ::= { unitSensorLogEntry 6 } -logUnitSensorSignedAvgValue OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The average sensor reading for the log period as a signed integer. - The value of this OID variable should be scaled by - unitSensorDecimalDigits. For example, if the value is 1 and - unitSensorDecimalDigits is 2, then actual value is 0.01. - This value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647)." - ::= { unitSensorLogEntry 7 } +logUnitSensorSignedAvgValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The average sensor reading for the log period as a signed integer. + The value of this OID variable should be scaled by + unitSensorDecimalDigits. For example, if the value is 1 and + unitSensorDecimalDigits is 2, then actual value is 0.01. + This value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This object does not apply to sensors without numerical reading." + ::= { unitSensorLogEntry 7 } -logUnitSensorSignedMaxValue OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The maximum sensor reading for the log period as a signed integer. - The value of this OID variable should be scaled by - unitSensorDecimalDigits. For example, if the value is 1 and - unitSensorDecimalDigits is 2, then actual value is 0.01. - This value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647)." - ::= { unitSensorLogEntry 8 } +logUnitSensorSignedMaxValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The maximum sensor reading for the log period as a signed integer. + The value of this OID variable should be scaled by + unitSensorDecimalDigits. For example, if the value is 1 and + unitSensorDecimalDigits is 2, then actual value is 0.01. + This value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This object does not apply to sensors without numerical reading." + ::= { unitSensorLogEntry 8 } -logUnitSensorSignedMinValue OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The minimum sensor reading for the log period as a signed integer. - The value of this OID variable should be scaled by - unitSensorDecimalDigits. For example, if the value is 1 and - unitSensorDecimalDigits is 2, then actual value is 0.01. - This value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647)." - ::= { unitSensorLogEntry 9 } +logUnitSensorSignedMinValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The minimum sensor reading for the log period as a signed integer. + The value of this OID variable should be scaled by + unitSensorDecimalDigits. For example, if the value is 1 and + unitSensorDecimalDigits is 2, then actual value is 0.01. + This value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This object does not apply to sensors without numerical reading." + ::= { unitSensorLogEntry 9 } +-- inletSensorLogTable: inlet sensor log data +inletSensorLogTable OBJECT-TYPE + SYNTAX SEQUENCE OF InletSensorLogEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of inlet sensor entries in the log." + ::= { logInlet 3 } --- The inletSensorLogTable - - - -inletSensorLogTable OBJECT-TYPE - SYNTAX SEQUENCE OF InletSensorLogEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A list of inlet sensor entries. The number of - entries is given by the value of inletCount for the PDU." - ::= { logInlet 3 } - -inletSensorLogEntry OBJECT-TYPE - SYNTAX InletSensorLogEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "An entry containing log objects for an inlet sensor." - INDEX { pduId, inletId, sensorType, logIndex } - ::= { inletSensorLogTable 1 } +inletSensorLogEntry OBJECT-TYPE + SYNTAX InletSensorLogEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing log objects for an inlet sensor." + INDEX { pduId, inletId, sensorType, logIndex } + ::= { inletSensorLogTable 1 } InletSensorLogEntryStruct ::= SEQUENCE { - logInletSensorDataAvailable TruthValue, - logInletSensorState SensorStateEnumeration, - logInletSensorAvgValue Unsigned32, - logInletSensorMaxValue Unsigned32, - logInletSensorMinValue Unsigned32, - logInletSensorSignedAvgValue Integer32, - logInletSensorSignedMaxValue Integer32, - logInletSensorSignedMinValue Integer32 - } + logInletSensorDataAvailable TruthValue, + logInletSensorState SensorStateEnumeration, + logInletSensorAvgValue Unsigned32, + logInletSensorMaxValue Unsigned32, + logInletSensorMinValue Unsigned32, + logInletSensorSignedAvgValue Integer32, + logInletSensorSignedMaxValue Integer32, + logInletSensorSignedMinValue Integer32 + } -logInletSensorDataAvailable OBJECT-TYPE - SYNTAX TruthValue - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "Is data available for this sensor during this measurement period?" - ::= { inletSensorLogEntry 2 } +logInletSensorDataAvailable OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Is data available for this sensor during this measurement period?" + ::= { inletSensorLogEntry 2 } -logInletSensorState OBJECT-TYPE - SYNTAX SensorStateEnumeration - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The sensor state." - ::= { inletSensorLogEntry 3 } +logInletSensorState OBJECT-TYPE + SYNTAX SensorStateEnumeration + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The most critical sensor state during this measurement period." + ::= { inletSensorLogEntry 3 } -logInletSensorAvgValue OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The average sensor reading for the log period as an unsigned integer. - The value of this OID variable should be scaled by - inletSensorDecimalDigits. For example, if the value is 1 and - inletSensorDecimalDigits is 2, then actual value is 0.01. - This value will wrap around if the scaled sensor reading exceeds - 4294967295. It is undefined for sensors which can have negative - readings." - ::= { inletSensorLogEntry 4 } +logInletSensorAvgValue OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The average sensor reading for the log period as an unsigned integer. + The value of this OID variable should be scaled by + inletSensorDecimalDigits. For example, if the value is 1 and + inletSensorDecimalDigits is 2, then actual value is 0.01. + This value will wrap around if the scaled sensor reading exceeds + 4294967295. It is undefined for sensors which can have negative + readings. + This object does not apply to sensors without numerical reading." + ::= { inletSensorLogEntry 4 } -logInletSensorMaxValue OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The maximum sensor reading for the log period as an unsigned integer. - The value of this OID variable should be scaled by - inletSensorDecimalDigits. For example, if the value is 1 and - inletSensorDecimalDigits is 2, then actual value is 0.01. - This value will wrap around if the scaled sensor reading exceeds - 4294967295. It is undefined for sensors which can have negative - readings." - ::= { inletSensorLogEntry 5 } +logInletSensorMaxValue OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The maximum sensor reading for the log period as an unsigned integer. + The value of this OID variable should be scaled by + inletSensorDecimalDigits. For example, if the value is 1 and + inletSensorDecimalDigits is 2, then actual value is 0.01. + This value will wrap around if the scaled sensor reading exceeds + 4294967295. It is undefined for sensors which can have negative + readings. + This object does not apply to sensors without numerical reading." + ::= { inletSensorLogEntry 5 } -logInletSensorMinValue OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The minimum sensor reading for the log period as an unsigned integer. - The value of this OID variable should be scaled by - inletSensorDecimalDigits. For example, if the value is 1 and - inletSensorDecimalDigits is 2, then actual value is 0.01. - This value will wrap around if the scaled sensor reading exceeds - 4294967295. It is undefined for sensors which can have negative - readings." - ::= { inletSensorLogEntry 6 } +logInletSensorMinValue OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The minimum sensor reading for the log period as an unsigned integer. + The value of this OID variable should be scaled by + inletSensorDecimalDigits. For example, if the value is 1 and + inletSensorDecimalDigits is 2, then actual value is 0.01. + This value will wrap around if the scaled sensor reading exceeds + 4294967295. It is undefined for sensors which can have negative + readings. + This object does not apply to sensors without numerical reading." + ::= { inletSensorLogEntry 6 } -logInletSensorSignedAvgValue OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The average sensor reading for the log period as a signed integer. - The value of this OID variable should be scaled by - inletSensorDecimalDigits. For example, if the value is 1 and - inletSensorDecimalDigits is 2, then actual value is 0.01. - This value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647)." - ::= { inletSensorLogEntry 7 } +logInletSensorSignedAvgValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The average sensor reading for the log period as a signed integer. + The value of this OID variable should be scaled by + inletSensorDecimalDigits. For example, if the value is 1 and + inletSensorDecimalDigits is 2, then actual value is 0.01. + This value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This object does not apply to sensors without numerical reading." + ::= { inletSensorLogEntry 7 } -logInletSensorSignedMaxValue OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The maximum sensor reading for the log period as a signed integer. - The value of this OID variable should be scaled by - inletSensorDecimalDigits. For example, if the value is 1 and - inletSensorDecimalDigits is 2, then actual value is 0.01. - This value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647)." - ::= { inletSensorLogEntry 8 } +logInletSensorSignedMaxValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The maximum sensor reading for the log period as a signed integer. + The value of this OID variable should be scaled by + inletSensorDecimalDigits. For example, if the value is 1 and + inletSensorDecimalDigits is 2, then actual value is 0.01. + This value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This object does not apply to sensors without numerical reading." + ::= { inletSensorLogEntry 8 } -logInletSensorSignedMinValue OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The minimum sensor reading for the log period as a signed integer. - The value of this OID variable should be scaled by - inletSensorDecimalDigits. For example, if the value is 1 and - inletSensorDecimalDigits is 2, then actual value is 0.01. - This value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647)." - ::= { inletSensorLogEntry 9 } +logInletSensorSignedMinValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The minimum sensor reading for the log period as a signed integer. + The value of this OID variable should be scaled by + inletSensorDecimalDigits. For example, if the value is 1 and + inletSensorDecimalDigits is 2, then actual value is 0.01. + This value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This object does not apply to sensors without numerical reading." + ::= { inletSensorLogEntry 9 } +-- inletPoleSensorLogTable: inlet pole sensor log data --- The inletPoleSensorLogTable +inletPoleSensorLogTable OBJECT-TYPE + SYNTAX SEQUENCE OF InletPoleSensorLogEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of inletPole sensor entries in the log." + ::= { logInlet 4 } -inletPoleSensorLogTable OBJECT-TYPE - SYNTAX SEQUENCE OF InletPoleSensorLogEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A list of inletPole sensor entries. The number of - entries is given by the value of inletPoleCount for the inlet." - ::= { logInlet 4 } - -inletPoleSensorLogEntry OBJECT-TYPE - SYNTAX InletPoleSensorLogEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "An entry containing log objects for an inletPole sensor." - INDEX { pduId,inletId, inletPoleIndex,sensorType,logIndex } - ::= { inletPoleSensorLogTable 1 } +inletPoleSensorLogEntry OBJECT-TYPE + SYNTAX InletPoleSensorLogEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing log objects for an inlet pole sensor." + INDEX { pduId, inletId, inletPoleIndex, sensorType, logIndex } + ::= { inletPoleSensorLogTable 1 } InletPoleSensorLogEntryStruct ::= SEQUENCE { - logInletPoleSensorDataAvailable TruthValue, - logInletPoleSensorState SensorStateEnumeration, - logInletPoleSensorAvgValue Unsigned32, - logInletPoleSensorMaxValue Unsigned32, - logInletPoleSensorMinValue Unsigned32, - logInletPoleSensorSignedAvgValue Integer32, - logInletPoleSensorSignedMaxValue Integer32, - logInletPoleSensorSignedMinValue Integer32 - } + logInletPoleSensorDataAvailable TruthValue, + logInletPoleSensorState SensorStateEnumeration, + logInletPoleSensorAvgValue Unsigned32, + logInletPoleSensorMaxValue Unsigned32, + logInletPoleSensorMinValue Unsigned32, + logInletPoleSensorSignedAvgValue Integer32, + logInletPoleSensorSignedMaxValue Integer32, + logInletPoleSensorSignedMinValue Integer32 + } -logInletPoleSensorDataAvailable OBJECT-TYPE - SYNTAX TruthValue - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "Is data available for this sensor during this measurement period?" - ::= { inletPoleSensorLogEntry 2 } +logInletPoleSensorDataAvailable OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Is data available for this sensor during this measurement period?" + ::= { inletPoleSensorLogEntry 2 } +logInletPoleSensorState OBJECT-TYPE + SYNTAX SensorStateEnumeration + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The most critical sensor state during this measurement period." + ::= { inletPoleSensorLogEntry 3 } -logInletPoleSensorState OBJECT-TYPE - SYNTAX SensorStateEnumeration - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The sensor state." - ::= { inletPoleSensorLogEntry 3 } +logInletPoleSensorAvgValue OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The average sensor reading for the log period as an unsigned integer. + The value of this OID variable should be scaled by + inletPoleSensorDecimalDigits. For example, if the value is 1 and + inletPoleSensorDecimalDigits is 2, then actual value is 0.01. + This value will wrap around if the scaled sensor reading exceeds + 4294967295. It is undefined for sensors which can have negative + readings. + This object does not apply to sensors without numerical reading." + ::= { inletPoleSensorLogEntry 4 } -logInletPoleSensorAvgValue OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The average sensor reading for the log period as an unsigned integer. - The value of this OID variable should be scaled by - inletPoleSensorDecimalDigits. For example, if the value is 1 and - inletPoleSensorDecimalDigits is 2, then actual value is 0.01. - This value will wrap around if the scaled sensor reading exceeds - 4294967295. It is undefined for sensors which can have negative - readings." - ::= { inletPoleSensorLogEntry 4 } +logInletPoleSensorMaxValue OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The maximum sensor reading for the log period as an unsigned integer. + The value of this OID variable should be scaled by + inletPoleSensorDecimalDigits. For example, if the value is 1 and + inletPoleSensorDecimalDigits is 2, then actual value is 0.01. + This value will wrap around if the scaled sensor reading exceeds + 4294967295. It is undefined for sensors which can have negative + readings. + This object does not apply to sensors without numerical reading." + ::= { inletPoleSensorLogEntry 5 } -logInletPoleSensorMaxValue OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The maximum sensor reading for the log period as an unsigned integer. - The value of this OID variable should be scaled by - inletPoleSensorDecimalDigits. For example, if the value is 1 and - inletPoleSensorDecimalDigits is 2, then actual value is 0.01. - This value will wrap around if the scaled sensor reading exceeds - 4294967295. It is undefined for sensors which can have negative - readings." - ::= { inletPoleSensorLogEntry 5 } +logInletPoleSensorMinValue OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The minimum sensor reading for the log period as an unsigned integer. + The value of this OID variable should be scaled by + inletPoleSensorDecimalDigits. For example, if the value is 1 and + inletPoleSensorDecimalDigits is 2, then actual value is 0.01. + This value will wrap around if the scaled sensor reading exceeds + 4294967295. It is undefined for sensors which can have negative + readings. + This object does not apply to sensors without numerical reading." + ::= { inletPoleSensorLogEntry 6 } -logInletPoleSensorMinValue OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The minimum sensor reading for the log period as an unsigned integer. - The value of this OID variable should be scaled by - inletPoleSensorDecimalDigits. For example, if the value is 1 and - inletPoleSensorDecimalDigits is 2, then actual value is 0.01. - This value will wrap around if the scaled sensor reading exceeds - 4294967295. It is undefined for sensors which can have negative - readings." - ::= { inletPoleSensorLogEntry 6 } +logInletPoleSensorSignedAvgValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The average sensor reading for the log period as a signed integer. + The value of this OID variable should be scaled by + inletPoleSensorDecimalDigits. For example, if the value is 1 and + inletPoleSensorDecimalDigits is 2, then actual value is 0.01. + This value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This object does not apply to sensors without numerical reading." + ::= { inletPoleSensorLogEntry 7 } -logInletPoleSensorSignedAvgValue OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The average sensor reading for the log period as a signed integer. - The value of this OID variable should be scaled by - inletPoleSensorDecimalDigits. For example, if the value is 1 and - inletPoleSensorDecimalDigits is 2, then actual value is 0.01. - This value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647)." - ::= { inletPoleSensorLogEntry 7 } +logInletPoleSensorSignedMaxValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The maximum sensor reading for the log period as a signed integer. + The value of this OID variable should be scaled by + inletPoleSensorDecimalDigits. For example, if the value is 1 and + inletPoleSensorDecimalDigits is 2, then actual value is 0.01. + This value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This object does not apply to sensors without numerical reading." + ::= { inletPoleSensorLogEntry 8 } -logInletPoleSensorSignedMaxValue OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The maximum sensor reading for the log period as a signed integer. - The value of this OID variable should be scaled by - inletPoleSensorDecimalDigits. For example, if the value is 1 and - inletPoleSensorDecimalDigits is 2, then actual value is 0.01. - This value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647)." - ::= { inletPoleSensorLogEntry 8 } +logInletPoleSensorSignedMinValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The minimum sensor reading for the log period as a signed integer. + The value of this OID variable should be scaled by + inletPoleSensorDecimalDigits. For example, if the value is 1 and + inletPoleSensorDecimalDigits is 2, then actual value is 0.01. + This value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This object does not apply to sensors without numerical reading." + ::= { inletPoleSensorLogEntry 9 } -logInletPoleSensorSignedMinValue OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The minimum sensor reading for the log period as a signed integer. - The value of this OID variable should be scaled by - inletPoleSensorDecimalDigits. For example, if the value is 1 and - inletPoleSensorDecimalDigits is 2, then actual value is 0.01. - This value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647)." - ::= { inletPoleSensorLogEntry 9 } +-- outletSensorLogTable: outlet sensor log data +outletSensorLogTable OBJECT-TYPE + SYNTAX SEQUENCE OF OutletSensorLogEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of outlet sensor entries in the log." + ::= { logOutlet 3 } - --- The outletSensorLogTable - -outletSensorLogTable OBJECT-TYPE - SYNTAX SEQUENCE OF OutletSensorLogEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A list of outlet sensor entries. The number of - entries is given by the value of outletCount for the PDU." - ::= { logOutlet 3 } - -outletSensorLogEntry OBJECT-TYPE - SYNTAX OutletSensorLogEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "An entry containing log objects for an outlet sensor." - INDEX { pduId, outletId, sensorType,logIndex } - ::= { outletSensorLogTable 1 } +outletSensorLogEntry OBJECT-TYPE + SYNTAX OutletSensorLogEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing log objects for an outlet sensor." + INDEX { pduId, outletId, sensorType, logIndex } + ::= { outletSensorLogTable 1 } OutletSensorLogEntryStruct ::= SEQUENCE { - logOutletSensorDataAvailable TruthValue, - logOutletSensorState SensorStateEnumeration, - logOutletSensorAvgValue Unsigned32, - logOutletSensorMaxValue Unsigned32, - logOutletSensorMinValue Unsigned32, - logOutletSensorSignedAvgValue Integer32, - logOutletSensorSignedMaxValue Integer32, - logOutletSensorSignedMinValue Integer32 - } + logOutletSensorDataAvailable TruthValue, + logOutletSensorState SensorStateEnumeration, + logOutletSensorAvgValue Unsigned32, + logOutletSensorMaxValue Unsigned32, + logOutletSensorMinValue Unsigned32, + logOutletSensorSignedAvgValue Integer32, + logOutletSensorSignedMaxValue Integer32, + logOutletSensorSignedMinValue Integer32 + } -logOutletSensorDataAvailable OBJECT-TYPE - SYNTAX TruthValue - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "Is data available for this sensor during this measurement period?" - ::= { outletSensorLogEntry 2 } +logOutletSensorDataAvailable OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Is data available for this sensor during this measurement period?" + ::= { outletSensorLogEntry 2 } -logOutletSensorState OBJECT-TYPE - SYNTAX SensorStateEnumeration - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The sensor state." - ::= { outletSensorLogEntry 3 } +logOutletSensorState OBJECT-TYPE + SYNTAX SensorStateEnumeration + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The most critical sensor state during this measurement period." + ::= { outletSensorLogEntry 3 } -logOutletSensorAvgValue OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The average sensor reading for the log period as an unsigned integer. - The value of this OID variable should be scaled by - outletSensorDecimalDigits. For example, if the value is 1 and - outletSensorDecimalDigits is 2, then actual value is 0.01. - This value will wrap around if the scaled sensor reading exceeds - 4294967295. It is undefined for sensors which can have negative - readings." - ::= { outletSensorLogEntry 4 } +logOutletSensorAvgValue OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The average sensor reading for the log period as an unsigned integer. + The value of this OID variable should be scaled by + outletSensorDecimalDigits. For example, if the value is 1 and + outletSensorDecimalDigits is 2, then actual value is 0.01. + This value will wrap around if the scaled sensor reading exceeds + 4294967295. It is undefined for sensors which can have negative + readings. + This object does not apply to sensors without numerical reading." + ::= { outletSensorLogEntry 4 } -logOutletSensorMaxValue OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The maximum sensor reading for the log period as an unsigned integer. - The value of this OID variable should be scaled by - outletSensorDecimalDigits. For example, if the value is 1 and - outletSensorDecimalDigits is 2, then actual value is 0.01. - This value will wrap around if the scaled sensor reading exceeds - 4294967295. It is undefined for sensors which can have negative - readings." - ::= { outletSensorLogEntry 5 } +logOutletSensorMaxValue OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The maximum sensor reading for the log period as an unsigned integer. + The value of this OID variable should be scaled by + outletSensorDecimalDigits. For example, if the value is 1 and + outletSensorDecimalDigits is 2, then actual value is 0.01. + This value will wrap around if the scaled sensor reading exceeds + 4294967295. It is undefined for sensors which can have negative + readings. + This object does not apply to sensors without numerical reading." + ::= { outletSensorLogEntry 5 } -logOutletSensorMinValue OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The minimum sensor reading for the log period as an unsigned integer. - The value of this OID variable should be scaled by - outletSensorDecimalDigits. For example, if the value is 1 and - outletSensorDecimalDigits is 2, then actual value is 0.01. - This value will wrap around if the scaled sensor reading exceeds - 4294967295. It is undefined for sensors which can have negative - readings." - ::= { outletSensorLogEntry 6 } +logOutletSensorMinValue OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The minimum sensor reading for the log period as an unsigned integer. + The value of this OID variable should be scaled by + outletSensorDecimalDigits. For example, if the value is 1 and + outletSensorDecimalDigits is 2, then actual value is 0.01. + This value will wrap around if the scaled sensor reading exceeds + 4294967295. It is undefined for sensors which can have negative + readings. + This object does not apply to sensors without numerical reading." + ::= { outletSensorLogEntry 6 } -logOutletSensorSignedAvgValue OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The average sensor reading for the log period as a signed integer. - The value of this OID variable should be scaled by - outletSensorDecimalDigits. For example, if the value is 1 and - outletSensorDecimalDigits is 2, then actual value is 0.01. - This value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647)." - ::= { outletSensorLogEntry 7 } +logOutletSensorSignedAvgValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The average sensor reading for the log period as a signed integer. + The value of this OID variable should be scaled by + outletSensorDecimalDigits. For example, if the value is 1 and + outletSensorDecimalDigits is 2, then actual value is 0.01. + This value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This object does not apply to sensors without numerical reading." + ::= { outletSensorLogEntry 7 } -logOutletSensorSignedMaxValue OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The maximum sensor reading for the log period as a signed integer. - The value of this OID variable should be scaled by - outletSensorDecimalDigits. For example, if the value is 1 and - outletSensorDecimalDigits is 2, then actual value is 0.01. - This value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647)." - ::= { outletSensorLogEntry 8 } +logOutletSensorSignedMaxValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The maximum sensor reading for the log period as a signed integer. + The value of this OID variable should be scaled by + outletSensorDecimalDigits. For example, if the value is 1 and + outletSensorDecimalDigits is 2, then actual value is 0.01. + This value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This object does not apply to sensors without numerical reading." + ::= { outletSensorLogEntry 8 } -logOutletSensorSignedMinValue OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The minimum sensor reading for the log period as a signed integer. - The value of this OID variable should be scaled by - outletSensorDecimalDigits. For example, if the value is 1 and - outletSensorDecimalDigits is 2, then actual value is 0.01. - This value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647)." - ::= { outletSensorLogEntry 9 } +logOutletSensorSignedMinValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The minimum sensor reading for the log period as a signed integer. + The value of this OID variable should be scaled by + outletSensorDecimalDigits. For example, if the value is 1 and + outletSensorDecimalDigits is 2, then actual value is 0.01. + This value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This object does not apply to sensors without numerical reading." + ::= { outletSensorLogEntry 9 } +-- outletPoleSensorLogTable: outlet pole sensor log data +outletPoleSensorLogTable OBJECT-TYPE + SYNTAX SEQUENCE OF OutletPoleSensorLogEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of outlet pole sensor entries in the log." + ::= { logOutlet 4 } --- The outletPoleSensorLogTable - -outletPoleSensorLogTable OBJECT-TYPE - SYNTAX SEQUENCE OF OutletPoleSensorLogEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A list of outletPole sensor entries. The number of - entries is given by the value of outletPoleCount for the outlet." - ::= { logOutlet 4 } - -outletPoleSensorLogEntry OBJECT-TYPE - SYNTAX OutletPoleSensorLogEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "An entry containing log objects for an outletPole sensor." - INDEX { pduId, outletId, outletPoleIndex,sensorType,logIndex } - ::= { outletPoleSensorLogTable 1 } +outletPoleSensorLogEntry OBJECT-TYPE + SYNTAX OutletPoleSensorLogEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing log objects for an outlet pole sensor." + INDEX { pduId, outletId, outletPoleIndex, sensorType, logIndex } + ::= { outletPoleSensorLogTable 1 } OutletPoleSensorLogEntryStruct ::= SEQUENCE { - logOutletPoleSensorDataAvailable TruthValue, - logOutletPoleSensorState SensorStateEnumeration, - logOutletPoleSensorAvgValue Unsigned32, - logOutletPoleSensorMaxValue Unsigned32, - logOutletPoleSensorMinValue Unsigned32, - logOutletPoleSensorSignedAvgValue Integer32, - logOutletPoleSensorSignedMaxValue Integer32, - logOutletPoleSensorSignedMinValue Integer32 - } + logOutletPoleSensorDataAvailable TruthValue, + logOutletPoleSensorState SensorStateEnumeration, + logOutletPoleSensorAvgValue Unsigned32, + logOutletPoleSensorMaxValue Unsigned32, + logOutletPoleSensorMinValue Unsigned32, + logOutletPoleSensorSignedAvgValue Integer32, + logOutletPoleSensorSignedMaxValue Integer32, + logOutletPoleSensorSignedMinValue Integer32 + } -logOutletPoleSensorDataAvailable OBJECT-TYPE - SYNTAX TruthValue - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "Is data available for this sensor during this measurement period?" - ::= { outletPoleSensorLogEntry 2 } +logOutletPoleSensorDataAvailable OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Is data available for this sensor during this measurement period?" + ::= { outletPoleSensorLogEntry 2 } -logOutletPoleSensorState OBJECT-TYPE - SYNTAX SensorStateEnumeration - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The sensor state." - ::= { outletPoleSensorLogEntry 3 } +logOutletPoleSensorState OBJECT-TYPE + SYNTAX SensorStateEnumeration + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The most critical sensor state during this measurement period." + ::= { outletPoleSensorLogEntry 3 } -logOutletPoleSensorAvgValue OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The average sensor reading for the log period as an unsigned integer. - The value of this OID variable should be scaled by - outletPoleSensorDecimalDigits. For example, if the value is 1 and - outletPoleSensorDecimalDigits is 2, then actual value is 0.01. - This value will wrap around if the scaled sensor reading exceeds - 4294967295. It is undefined for sensors which can have negative - readings." - ::= { outletPoleSensorLogEntry 4 } +logOutletPoleSensorAvgValue OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The average sensor reading for the log period as an unsigned integer. + The value of this OID variable should be scaled by + outletPoleSensorDecimalDigits. For example, if the value is 1 and + outletPoleSensorDecimalDigits is 2, then actual value is 0.01. + This value will wrap around if the scaled sensor reading exceeds + 4294967295. It is undefined for sensors which can have negative + readings. + This object does not apply to sensors without numerical reading." + ::= { outletPoleSensorLogEntry 4 } -logOutletPoleSensorMaxValue OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The maximum sensor reading for the log period as an unsigned integer. - The value of this OID variable should be scaled by - outletPoleSensorDecimalDigits. For example, if the value is 1 and - outletPoleSensorDecimalDigits is 2, then actual value is 0.01. - This value will wrap around if the scaled sensor reading exceeds - 4294967295. It is undefined for sensors which can have negative - readings." - ::= { outletPoleSensorLogEntry 5 } +logOutletPoleSensorMaxValue OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The maximum sensor reading for the log period as an unsigned integer. + The value of this OID variable should be scaled by + outletPoleSensorDecimalDigits. For example, if the value is 1 and + outletPoleSensorDecimalDigits is 2, then actual value is 0.01. + This value will wrap around if the scaled sensor reading exceeds + 4294967295. It is undefined for sensors which can have negative + readings. + This object does not apply to sensors without numerical reading." + ::= { outletPoleSensorLogEntry 5 } -logOutletPoleSensorMinValue OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The minimum sensor reading for the log period as an unsigned integer. - The value of this OID variable should be scaled by - outletPoleSensorDecimalDigits. For example, if the value is 1 and - outletPoleSensorDecimalDigits is 2, then actual value is 0.01. - This value will wrap around if the scaled sensor reading exceeds - 4294967295. It is undefined for sensors which can have negative - readings." - ::= { outletPoleSensorLogEntry 6 } +logOutletPoleSensorMinValue OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The minimum sensor reading for the log period as an unsigned integer. + The value of this OID variable should be scaled by + outletPoleSensorDecimalDigits. For example, if the value is 1 and + outletPoleSensorDecimalDigits is 2, then actual value is 0.01. + This value will wrap around if the scaled sensor reading exceeds + 4294967295. It is undefined for sensors which can have negative + readings. + This object does not apply to sensors without numerical reading." + ::= { outletPoleSensorLogEntry 6 } -logOutletPoleSensorSignedAvgValue OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The average sensor reading for the log period as a signed integer. - The value of this OID variable should be scaled by - outletPoleSensorDecimalDigits. For example, if the value is 1 and - outletPoleSensorDecimalDigits is 2, then actual value is 0.01. - This value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647)." - ::= { outletPoleSensorLogEntry 7 } +logOutletPoleSensorSignedAvgValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The average sensor reading for the log period as a signed integer. + The value of this OID variable should be scaled by + outletPoleSensorDecimalDigits. For example, if the value is 1 and + outletPoleSensorDecimalDigits is 2, then actual value is 0.01. + This value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This object does not apply to sensors without numerical reading." + ::= { outletPoleSensorLogEntry 7 } -logOutletPoleSensorSignedMaxValue OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The maximum sensor reading for the log period as a signed integer. - The value of this OID variable should be scaled by - outletPoleSensorDecimalDigits. For example, if the value is 1 and - outletPoleSensorDecimalDigits is 2, then actual value is 0.01. - This value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647)." - ::= { outletPoleSensorLogEntry 8 } +logOutletPoleSensorSignedMaxValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The maximum sensor reading for the log period as a signed integer. + The value of this OID variable should be scaled by + outletPoleSensorDecimalDigits. For example, if the value is 1 and + outletPoleSensorDecimalDigits is 2, then actual value is 0.01. + This value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This object does not apply to sensors without numerical reading." + ::= { outletPoleSensorLogEntry 8 } -logOutletPoleSensorSignedMinValue OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The minimum sensor reading for the log period as a signed integer. - The value of this OID variable should be scaled by - outletPoleSensorDecimalDigits. For example, if the value is 1 and - outletPoleSensorDecimalDigits is 2, then actual value is 0.01. - This value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647)." - ::= { outletPoleSensorLogEntry 9 } +logOutletPoleSensorSignedMinValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The minimum sensor reading for the log period as a signed integer. + The value of this OID variable should be scaled by + outletPoleSensorDecimalDigits. For example, if the value is 1 and + outletPoleSensorDecimalDigits is 2, then actual value is 0.01. + This value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This object does not apply to sensors without numerical reading." + ::= { outletPoleSensorLogEntry 9 } +-- overCurrentProtectorSensorLogTable: overcurrent protector sensor log data +overCurrentProtectorSensorLogTable OBJECT-TYPE + SYNTAX SEQUENCE OF OverCurrentProtectorSensorLogEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of overcurrent protector sensor entries in the log." + ::= { logOverCurrentProtector 3 } --- The overCurrentProtectorSensorLogTable - -overCurrentProtectorSensorLogTable OBJECT-TYPE - SYNTAX SEQUENCE OF OverCurrentProtectorSensorLogEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A list of overCurrentProtector sensor entries. The number of - entries is given by the value of overCurrentProtectorCount for the PDU." - ::= { logOverCurrentProtector 3 } - -overCurrentProtectorSensorLogEntry OBJECT-TYPE - SYNTAX OverCurrentProtectorSensorLogEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "An entry containing log objects for an overCurrentProtector sensor." - INDEX { pduId, overCurrentProtectorIndex, sensorType, logIndex } - ::= { overCurrentProtectorSensorLogTable 1 } +overCurrentProtectorSensorLogEntry OBJECT-TYPE + SYNTAX OverCurrentProtectorSensorLogEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing log objects for an overcurrent protector sensor." + INDEX { pduId, overCurrentProtectorIndex, sensorType, logIndex } + ::= { overCurrentProtectorSensorLogTable 1 } OverCurrentProtectorSensorLogEntryStruct ::= SEQUENCE { - logOverCurrentProtectorSensorDataAvailable TruthValue, - logOverCurrentProtectorSensorState SensorStateEnumeration, - logOverCurrentProtectorSensorAvgValue Unsigned32, - logOverCurrentProtectorSensorMaxValue Unsigned32, - logOverCurrentProtectorSensorMinValue Unsigned32, - logOverCurrentProtectorSensorSignedAvgValue Integer32, - logOverCurrentProtectorSensorSignedMaxValue Integer32, - logOverCurrentProtectorSensorSignedMinValue Integer32 - } + logOverCurrentProtectorSensorDataAvailable TruthValue, + logOverCurrentProtectorSensorState SensorStateEnumeration, + logOverCurrentProtectorSensorAvgValue Unsigned32, + logOverCurrentProtectorSensorMaxValue Unsigned32, + logOverCurrentProtectorSensorMinValue Unsigned32, + logOverCurrentProtectorSensorSignedAvgValue Integer32, + logOverCurrentProtectorSensorSignedMaxValue Integer32, + logOverCurrentProtectorSensorSignedMinValue Integer32 + } logOverCurrentProtectorSensorDataAvailable OBJECT-TYPE - SYNTAX TruthValue - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "Is data available for this sensor during this measurement period?" - ::= { overCurrentProtectorSensorLogEntry 2 } + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Is data available for this sensor during this measurement period?" + ::= { overCurrentProtectorSensorLogEntry 2 } -logOverCurrentProtectorSensorState OBJECT-TYPE - SYNTAX SensorStateEnumeration - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The sensor state." - ::= { overCurrentProtectorSensorLogEntry 3 } +logOverCurrentProtectorSensorState OBJECT-TYPE + SYNTAX SensorStateEnumeration + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The most critical sensor state during this measurement period." + ::= { overCurrentProtectorSensorLogEntry 3 } logOverCurrentProtectorSensorAvgValue OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The average sensor reading for the log period as an unsigned integer. - The value of this OID variable should be scaled by - overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and - overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01. - This value will wrap around if the scaled sensor reading exceeds - 4294967295. It is undefined for sensors which can have negative - readings." - ::= { overCurrentProtectorSensorLogEntry 4 } + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The average sensor reading for the log period as an unsigned integer. + The value of this OID variable should be scaled by + overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and + overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01. + This value will wrap around if the scaled sensor reading exceeds + 4294967295. It is undefined for sensors which can have negative + readings. + This object does not apply to sensors without numerical reading." + ::= { overCurrentProtectorSensorLogEntry 4 } logOverCurrentProtectorSensorMaxValue OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The maximum sensor reading for the log period as an unsigned integer. - The value of this OID variable should be scaled by - overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and - overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01. - This value will wrap around if the scaled sensor reading exceeds - 4294967295. It is undefined for sensors which can have negative - readings." - ::= { overCurrentProtectorSensorLogEntry 5 } + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The maximum sensor reading for the log period as an unsigned integer. + The value of this OID variable should be scaled by + overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and + overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01. + This value will wrap around if the scaled sensor reading exceeds + 4294967295. It is undefined for sensors which can have negative + readings. + This object does not apply to sensors without numerical reading." + ::= { overCurrentProtectorSensorLogEntry 5 } logOverCurrentProtectorSensorMinValue OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The minimum sensor reading for the log period as an unsigned integer. - The value of this OID variable should be scaled by - overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and - overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01. - This value will wrap around if the scaled sensor reading exceeds - 4294967295. It is undefined for sensors which can have negative - readings." - ::= { overCurrentProtectorSensorLogEntry 6 } + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The minimum sensor reading for the log period as an unsigned integer. + The value of this OID variable should be scaled by + overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and + overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01. + This value will wrap around if the scaled sensor reading exceeds + 4294967295. It is undefined for sensors which can have negative + readings. + This object does not apply to sensors without numerical reading." + ::= { overCurrentProtectorSensorLogEntry 6 } logOverCurrentProtectorSensorSignedAvgValue OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The average sensor reading for the log period as a signed integer. - The value of this OID variable should be scaled by - overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and - overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01. - This value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647)." - ::= { overCurrentProtectorSensorLogEntry 7 } + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The average sensor reading for the log period as a signed integer. + The value of this OID variable should be scaled by + overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and + overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01. + This value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This object does not apply to sensors without numerical reading." + ::= { overCurrentProtectorSensorLogEntry 7 } logOverCurrentProtectorSensorSignedMaxValue OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The maximum sensor reading for the log period as a signed integer. - The value of this OID variable should be scaled by - overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and - overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01. - This value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647)." - ::= { overCurrentProtectorSensorLogEntry 8 } + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The maximum sensor reading for the log period as a signed integer. + The value of this OID variable should be scaled by + overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and + overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01. + This value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This object does not apply to sensors without numerical reading." + ::= { overCurrentProtectorSensorLogEntry 8 } logOverCurrentProtectorSensorSignedMinValue OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The minimum sensor reading for the log period as a signed integer. - The value of this OID variable should be scaled by - overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and - overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01. - This value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647)." - ::= { overCurrentProtectorSensorLogEntry 9 } + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The minimum sensor reading for the log period as a signed integer. + The value of this OID variable should be scaled by + overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and + overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01. + This value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This object does not apply to sensors without numerical reading." + ::= { overCurrentProtectorSensorLogEntry 9 } +-- externalSensorLogTable: external sensor log data +externalSensorLogTable OBJECT-TYPE + SYNTAX SEQUENCE OF ExternalSensorLogEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of external sensor entries in the log." + ::= { logExternalSensor 3 } --- The externalSensorLogTable - -externalSensorLogTable OBJECT-TYPE - SYNTAX SEQUENCE OF ExternalSensorLogEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A list of external sensor entries. The number of - entries is given by the value of externalSensorCount for the PDU." - ::= { logExternalSensor 3 } - -externalSensorLogEntry OBJECT-TYPE - SYNTAX ExternalSensorLogEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "An entry containing log objects for an external sensor." - INDEX { pduId, sensorID, logIndex } - ::= { externalSensorLogTable 1 } +externalSensorLogEntry OBJECT-TYPE + SYNTAX ExternalSensorLogEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing log objects for an external sensor." + INDEX { pduId, sensorID, logIndex } + ::= { externalSensorLogTable 1 } ExternalSensorLogEntryStruct ::= SEQUENCE { - logExternalSensorDataAvailable TruthValue, - logExternalSensorState SensorStateEnumeration, - logExternalSensorAvgValue Integer32, - logExternalSensorMaxValue Integer32, - logExternalSensorMinValue Integer32 - } + logExternalSensorDataAvailable TruthValue, + logExternalSensorState SensorStateEnumeration, + logExternalSensorAvgValue Integer32, + logExternalSensorMaxValue Integer32, + logExternalSensorMinValue Integer32 + } -logExternalSensorDataAvailable OBJECT-TYPE - SYNTAX TruthValue - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "Is data available for this sensor during this measurement period?" - ::= { externalSensorLogEntry 2 } +logExternalSensorDataAvailable OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Is data available for this sensor during this measurement period?" + ::= { externalSensorLogEntry 2 } -logExternalSensorState OBJECT-TYPE - SYNTAX SensorStateEnumeration - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The sensor state." - ::= { externalSensorLogEntry 3 } +logExternalSensorState OBJECT-TYPE + SYNTAX SensorStateEnumeration + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The most critical sensor state during this measurement period." + ::= { externalSensorLogEntry 3 } -logExternalSensorAvgValue OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The sensor reading average value. - The value of this OID variable should be scaled by - externalSensorDecimalDigits. For example, if the value is 1 and - externalSensorDecimalDigits is 2, then actual value is 0.01." - ::= { externalSensorLogEntry 4 } +logExternalSensorAvgValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The sensor reading average value. + The value of this OID variable should be scaled by + externalSensorDecimalDigits. For example, if the value is 1 and + externalSensorDecimalDigits is 2, then actual value is 0.01. + This object does not apply to sensors without numerical reading." + ::= { externalSensorLogEntry 4 } -logExternalSensorMaxValue OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The sensor reading maximum value. - The value of this OID variable should be scaled by - externalSensorDecimalDigits. For example, if the value is 1 and - externalSensorDecimalDigits is 2, then actual value is 0.01." - ::= { externalSensorLogEntry 5 } +logExternalSensorMaxValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The sensor reading maximum value. + The value of this OID variable should be scaled by + externalSensorDecimalDigits. For example, if the value is 1 and + externalSensorDecimalDigits is 2, then actual value is 0.01. + This object does not apply to sensors without numerical reading." + ::= { externalSensorLogEntry 5 } -logExternalSensorMinValue OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The sensor reading minimum value. - The value of this OID variable should be scaled by - externalSensorDecimalDigits. For example, if the value is 1 and - externalSensorDecimalDigits is 2, then actual value is 0.01." - ::= { externalSensorLogEntry 6 } +logExternalSensorMinValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The sensor reading minimum value. + The value of this OID variable should be scaled by + externalSensorDecimalDigits. For example, if the value is 1 and + externalSensorDecimalDigits is 2, then actual value is 0.01. + This object does not apply to sensors without numerical reading." + ::= { externalSensorLogEntry 6 } +-- wireSensorLogTable: wire sensor log data --- The wireSensorLogTable +wireSensorLogTable OBJECT-TYPE + SYNTAX SEQUENCE OF WireSensorLogEntryStruct + MAX-ACCESS not-accessible + STATUS deprecated + DESCRIPTION + "A list of wire sensor entries in the log. + Note: This feature is no longer used, the table is always empty." + ::= { logWire 3 } -wireSensorLogTable OBJECT-TYPE - SYNTAX SEQUENCE OF WireSensorLogEntryStruct - MAX-ACCESS not-accessible - STATUS deprecated - DESCRIPTION - "A list of wire sensor entries. The number of - entries is given by the value of wireCount for the PDU." - ::= { logWire 3 } - -wireSensorLogEntry OBJECT-TYPE - SYNTAX WireSensorLogEntryStruct - MAX-ACCESS not-accessible - STATUS deprecated - DESCRIPTION - "An entry containing log objects for a wire sensor." - INDEX { pduId, wireId, sensorType, logIndex } - ::= { wireSensorLogTable 1 } +wireSensorLogEntry OBJECT-TYPE + SYNTAX WireSensorLogEntryStruct + MAX-ACCESS not-accessible + STATUS deprecated + DESCRIPTION + "An entry containing log objects for a wire sensor." + INDEX { pduId, wireId, sensorType, logIndex } + ::= { wireSensorLogTable 1 } WireSensorLogEntryStruct ::= SEQUENCE { - logWireSensorDataAvailable TruthValue, - logWireSensorState SensorStateEnumeration, - logWireSensorAvgValue Unsigned32, - logWireSensorMaxValue Unsigned32, - logWireSensorMinValue Unsigned32 - } + logWireSensorDataAvailable TruthValue, + logWireSensorState SensorStateEnumeration, + logWireSensorAvgValue Unsigned32, + logWireSensorMaxValue Unsigned32, + logWireSensorMinValue Unsigned32 + } -logWireSensorDataAvailable OBJECT-TYPE - SYNTAX TruthValue - MAX-ACCESS read-only - STATUS deprecated - DESCRIPTION - "Is data available for this sensor during this measurement period?" - ::= { wireSensorLogEntry 2 } +logWireSensorDataAvailable OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "Is data available for this sensor during this measurement period?" + ::= { wireSensorLogEntry 2 } -logWireSensorState OBJECT-TYPE - SYNTAX SensorStateEnumeration - MAX-ACCESS read-only - STATUS deprecated - DESCRIPTION - "The sensor state." - ::= { wireSensorLogEntry 3 } +logWireSensorState OBJECT-TYPE + SYNTAX SensorStateEnumeration + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The most critical sensor state during this measurement period." + ::= { wireSensorLogEntry 3 } -logWireSensorAvgValue OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS deprecated - DESCRIPTION - "The sensor reading average value. - The value of this OID variable should be scaled by - wireSensorDecimalDigits. For example, if the value is 1 and - wireSensorDecimalDigits is 2, then actual value is 0.01. - This value will wrap around if the value exceeds 4294967295" - ::= { wireSensorLogEntry 4 } +logWireSensorAvgValue OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The sensor reading average value. + The value of this OID variable should be scaled by + wireSensorDecimalDigits. For example, if the value is 1 and + wireSensorDecimalDigits is 2, then actual value is 0.01. + This value will wrap around if the value exceeds 4294967295. + This object does not apply to sensors without numerical reading." + ::= { wireSensorLogEntry 4 } -logWireSensorMaxValue OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS deprecated - DESCRIPTION - "The sensor reading maximum value. - The value of this OID variable should be scaled by - wireSensorDecimalDigits. For example, if the value is 1 and - wireSensorDecimalDigits is 2, then actual value is 0.01. - This value will wrap around if the value exceeds 4294967295" - ::= { wireSensorLogEntry 5 } +logWireSensorMaxValue OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The sensor reading maximum value. + The value of this OID variable should be scaled by + wireSensorDecimalDigits. For example, if the value is 1 and + wireSensorDecimalDigits is 2, then actual value is 0.01. + This value will wrap around if the value exceeds 4294967295. + This object does not apply to sensors without numerical reading." + ::= { wireSensorLogEntry 5 } -logWireSensorMinValue OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS deprecated - DESCRIPTION - "The sensor reading minimum value. - The value of this OID variable should be scaled by - wireSensorDecimalDigits. For example, if the value is 1 and - wireSensorDecimalDigits is 2, then actual value is 0.01. - This value will wrap around if the value exceeds 4294967295." - ::= { wireSensorLogEntry 6 } +logWireSensorMinValue OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The sensor reading minimum value. + The value of this OID variable should be scaled by + wireSensorDecimalDigits. For example, if the value is 1 and + wireSensorDecimalDigits is 2, then actual value is 0.01. + This value will wrap around if the value exceeds 4294967295. + This object does not apply to sensors without numerical reading." + ::= { wireSensorLogEntry 6 } +-- transferSwitchSensorLogTable: transfer switch sensor log data +transferSwitchSensorLogTable OBJECT-TYPE + SYNTAX SEQUENCE OF TransferSwitchSensorLogEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of transfer switch sensor entries in the log." + ::= { logTransferSwitch 3 } - - - --- The transferSwitchSensorLogTable - -transferSwitchSensorLogTable OBJECT-TYPE - SYNTAX SEQUENCE OF TransferSwitchSensorLogEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A list of Transfer Switch sensor entries. The number of - entries is given by the value of transferSwitchCount for the PDU." - ::= { logTransferSwitch 3 } - -transferSwitchSensorLogEntry OBJECT-TYPE - SYNTAX TransferSwitchSensorLogEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "An entry containing log objects for a transfer switch sensor." - INDEX { pduId, transferSwitchId, sensorType, logIndex } - ::= { transferSwitchSensorLogTable 1 } +transferSwitchSensorLogEntry OBJECT-TYPE + SYNTAX TransferSwitchSensorLogEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing log objects for a transfer switch sensor." + INDEX { pduId, transferSwitchId, sensorType, logIndex } + ::= { transferSwitchSensorLogTable 1 } TransferSwitchSensorLogEntryStruct ::= SEQUENCE { - logTransferSwitchSensorDataAvailable TruthValue, - logTransferSwitchSensorState SensorStateEnumeration, - logTransferSwitchSensorAvgValue Unsigned32, - logTransferSwitchSensorMaxValue Unsigned32, - logTransferSwitchSensorMinValue Unsigned32, - logTransferSwitchSensorSignedAvgValue Integer32, - logTransferSwitchSensorSignedMaxValue Integer32, - logTransferSwitchSensorSignedMinValue Integer32 - } + logTransferSwitchSensorDataAvailable TruthValue, + logTransferSwitchSensorState SensorStateEnumeration, + logTransferSwitchSensorAvgValue Unsigned32, + logTransferSwitchSensorMaxValue Unsigned32, + logTransferSwitchSensorMinValue Unsigned32, + logTransferSwitchSensorSignedAvgValue Integer32, + logTransferSwitchSensorSignedMaxValue Integer32, + logTransferSwitchSensorSignedMinValue Integer32 + } -logTransferSwitchSensorDataAvailable OBJECT-TYPE - SYNTAX TruthValue - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "Is data available for this sensor during this measurement period?" - ::= { transferSwitchSensorLogEntry 2 } +logTransferSwitchSensorDataAvailable OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Is data available for this sensor during this measurement period?" + ::= { transferSwitchSensorLogEntry 2 } -logTransferSwitchSensorState OBJECT-TYPE - SYNTAX SensorStateEnumeration - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The sensor state." - ::= { transferSwitchSensorLogEntry 3 } +logTransferSwitchSensorState OBJECT-TYPE + SYNTAX SensorStateEnumeration + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The most critical sensor state during this measurement period." + ::= { transferSwitchSensorLogEntry 3 } -logTransferSwitchSensorAvgValue OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The average sensor reading for the log period as an unsigned integer. - The value of this OID variable should be scaled by - transferSwitchSensorDecimalDigits. For example, if the value is 1 and - transferSwitchSensorDecimalDigits is 2, then actual value is 0.01. - This value will wrap around if the scaled sensor reading exceeds - 4294967295. It is undefined for sensors which can have negative - readings." - ::= { transferSwitchSensorLogEntry 4 } +logTransferSwitchSensorAvgValue OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The average sensor reading for the log period as an unsigned integer. + The value of this OID variable should be scaled by + transferSwitchSensorDecimalDigits. For example, if the value is 1 and + transferSwitchSensorDecimalDigits is 2, then actual value is 0.01. + This value will wrap around if the scaled sensor reading exceeds + 4294967295. It is undefined for sensors which can have negative + readings. + This object does not apply to sensors without numerical reading." + ::= { transferSwitchSensorLogEntry 4 } -logTransferSwitchSensorMaxValue OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The maximum sensor reading for the log period as an unsigned integer. - The value of this OID variable should be scaled by - transferSwitchSensorDecimalDigits. For example, if the value is 1 and - transferSwitchSensorDecimalDigits is 2, then actual value is 0.01. - This value will wrap around if the scaled sensor reading exceeds - 4294967295. It is undefined for sensors which can have negative - readings." - ::= { transferSwitchSensorLogEntry 5 } +logTransferSwitchSensorMaxValue OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The maximum sensor reading for the log period as an unsigned integer. + The value of this OID variable should be scaled by + transferSwitchSensorDecimalDigits. For example, if the value is 1 and + transferSwitchSensorDecimalDigits is 2, then actual value is 0.01. + This value will wrap around if the scaled sensor reading exceeds + 4294967295. It is undefined for sensors which can have negative + readings. + This object does not apply to sensors without numerical reading." + ::= { transferSwitchSensorLogEntry 5 } -logTransferSwitchSensorMinValue OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The minimum sensor reading for the log period as an unsigned integer. - The value of this OID variable should be scaled by - transferSwitchSensorDecimalDigits. For example, if the value is 1 and - transferSwitchSensorDecimalDigits is 2, then actual value is 0.01. - This value will wrap around if the scaled sensor reading exceeds - 4294967295. It is undefined for sensors which can have negative - readings." - ::= { transferSwitchSensorLogEntry 6 } +logTransferSwitchSensorMinValue OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The minimum sensor reading for the log period as an unsigned integer. + The value of this OID variable should be scaled by + transferSwitchSensorDecimalDigits. For example, if the value is 1 and + transferSwitchSensorDecimalDigits is 2, then actual value is 0.01. + This value will wrap around if the scaled sensor reading exceeds + 4294967295. It is undefined for sensors which can have negative + readings. + This object does not apply to sensors without numerical reading." + ::= { transferSwitchSensorLogEntry 6 } logTransferSwitchSensorSignedAvgValue OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The average sensor reading for the log period as a signed integer. - The value of this OID variable should be scaled by - transferSwitchSensorDecimalDigits. For example, if the value is 1 and - transferSwitchSensorDecimalDigits is 2, then actual value is 0.01. - This value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647)." - ::= { transferSwitchSensorLogEntry 7 } + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The average sensor reading for the log period as a signed integer. + The value of this OID variable should be scaled by + transferSwitchSensorDecimalDigits. For example, if the value is 1 and + transferSwitchSensorDecimalDigits is 2, then actual value is 0.01. + This value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This object does not apply to sensors without numerical reading." + ::= { transferSwitchSensorLogEntry 7 } logTransferSwitchSensorSignedMaxValue OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The maximum sensor reading for the log period as a signed integer. - The value of this OID variable should be scaled by - transferSwitchSensorDecimalDigits. For example, if the value is 1 and - transferSwitchSensorDecimalDigits is 2, then actual value is 0.01. - This value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647)." - ::= { transferSwitchSensorLogEntry 8 } + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The maximum sensor reading for the log period as a signed integer. + The value of this OID variable should be scaled by + transferSwitchSensorDecimalDigits. For example, if the value is 1 and + transferSwitchSensorDecimalDigits is 2, then actual value is 0.01. + This value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This object does not apply to sensors without numerical reading." + ::= { transferSwitchSensorLogEntry 8 } logTransferSwitchSensorSignedMinValue OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The minimum sensor reading for the log period as a signed integer. - The value of this OID variable should be scaled by - transferSwitchSensorDecimalDigits. For example, if the value is 1 and - transferSwitchSensorDecimalDigits is 2, then actual value is 0.01. - This value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647)." - ::= { transferSwitchSensorLogEntry 9 } + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The minimum sensor reading for the log period as a signed integer. + The value of this OID variable should be scaled by + transferSwitchSensorDecimalDigits. For example, if the value is 1 and + transferSwitchSensorDecimalDigits is 2, then actual value is 0.01. + This value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This object does not apply to sensors without numerical reading." + ::= { transferSwitchSensorLogEntry 9 } +-- circuitSensorLogTable: BCM2/PMC circuit sensor log data +circuitSensorLogTable OBJECT-TYPE + SYNTAX SEQUENCE OF CircuitSensorLogEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of circuit sensor entries in the log." + ::= { logCircuit 3 } --- the Measurements table +circuitSensorLogEntry OBJECT-TYPE + SYNTAX CircuitSensorLogEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing log objects for a circuit sensor." + INDEX { pduId, circuitId, sensorType, logIndex } + ::= { circuitSensorLogTable 1 } +CircuitSensorLogEntryStruct ::= SEQUENCE { + logCircuitSensorDataAvailable TruthValue, + logCircuitSensorState SensorStateEnumeration, + logCircuitSensorAvgValue Unsigned32, + logCircuitSensorMaxValue Unsigned32, + logCircuitSensorMinValue Unsigned32, + logCircuitSensorSignedAvgValue Integer32, + logCircuitSensorSignedMaxValue Integer32, + logCircuitSensorSignedMinValue Integer32 + } +logCircuitSensorDataAvailable OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Is data available for this sensor during this measurement period?" + ::= { circuitSensorLogEntry 2 } --- The unitSensorMeasurementsTable +logCircuitSensorState OBJECT-TYPE + SYNTAX SensorStateEnumeration + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The most critical sensor state during this measurement period." + ::= { circuitSensorLogEntry 3 } -unitSensorMeasurementsTable OBJECT-TYPE - SYNTAX SEQUENCE OF UnitSensorMeasurementsEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A list of unit sensor entries." - ::= { measurementsUnit 3 } +logCircuitSensorAvgValue OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The average sensor reading for the log period as an unsigned integer. + The value of this OID variable should be scaled by + inletSensorDecimalDigits. For example, if the value is 1 and + inletSensorDecimalDigits is 2, then actual value is 0.01. + This value will wrap around if the scaled sensor reading exceeds + 4294967295. It is undefined for sensors which can have negative + readings. + This object does not apply to sensors without numerical reading." + ::= { circuitSensorLogEntry 4 } -unitSensorMeasurementsEntry OBJECT-TYPE - SYNTAX UnitSensorMeasurementsEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "An entry containing measurement objects for an unit sensor." - INDEX { pduId, sensorType } - ::= { unitSensorMeasurementsTable 1 } +logCircuitSensorMaxValue OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The maximum sensor reading for the log period as an unsigned integer. + The value of this OID variable should be scaled by + inletSensorDecimalDigits. For example, if the value is 1 and + inletSensorDecimalDigits is 2, then actual value is 0.01. + This value will wrap around if the scaled sensor reading exceeds + 4294967295. It is undefined for sensors which can have negative + readings. + This object does not apply to sensors without numerical reading." + ::= { circuitSensorLogEntry 5 } + +logCircuitSensorMinValue OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The minimum sensor reading for the log period as an unsigned integer. + The value of this OID variable should be scaled by + inletSensorDecimalDigits. For example, if the value is 1 and + inletSensorDecimalDigits is 2, then actual value is 0.01. + This value will wrap around if the scaled sensor reading exceeds + 4294967295. It is undefined for sensors which can have negative + readings. + This object does not apply to sensors without numerical reading." + ::= { circuitSensorLogEntry 6 } + +logCircuitSensorSignedAvgValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The average sensor reading for the log period as a signed integer. + The value of this OID variable should be scaled by + inletSensorDecimalDigits. For example, if the value is 1 and + inletSensorDecimalDigits is 2, then actual value is 0.01. + This value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This object does not apply to sensors without numerical reading." + ::= { circuitSensorLogEntry 7 } + +logCircuitSensorSignedMaxValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The maximum sensor reading for the log period as a signed integer. + The value of this OID variable should be scaled by + inletSensorDecimalDigits. For example, if the value is 1 and + inletSensorDecimalDigits is 2, then actual value is 0.01. + This value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This object does not apply to sensors without numerical reading." + ::= { circuitSensorLogEntry 8 } + +logCircuitSensorSignedMinValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The minimum sensor reading for the log period as a signed integer. + The value of this OID variable should be scaled by + inletSensorDecimalDigits. For example, if the value is 1 and + inletSensorDecimalDigits is 2, then actual value is 0.01. + This value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This object does not apply to sensors without numerical reading." + ::= { circuitSensorLogEntry 9 } + +-- circuitPoleSensorLogTable: BCM2/PMC circuit pole sensor log data + +circuitPoleSensorLogTable OBJECT-TYPE + SYNTAX SEQUENCE OF CircuitPoleSensorLogEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of circuit pole sensor entries in the log." + ::= { logCircuit 5 } + +circuitPoleSensorLogEntry OBJECT-TYPE + SYNTAX CircuitPoleSensorLogEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing log objects for a circuit pole sensor." + INDEX { pduId, circuitId, circuitPoleId, sensorType, logIndex } + ::= { circuitPoleSensorLogTable 1 } + +CircuitPoleSensorLogEntryStruct ::= SEQUENCE { + logCircuitPoleSensorDataAvailable TruthValue, + logCircuitPoleSensorState SensorStateEnumeration, + logCircuitPoleSensorAvgValue Unsigned32, + logCircuitPoleSensorMaxValue Unsigned32, + logCircuitPoleSensorMinValue Unsigned32, + logCircuitPoleSensorSignedAvgValue Integer32, + logCircuitPoleSensorSignedMaxValue Integer32, + logCircuitPoleSensorSignedMinValue Integer32 + } + +logCircuitPoleSensorDataAvailable OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Is data available for this sensor during this measurement period?" + ::= { circuitPoleSensorLogEntry 2 } + +logCircuitPoleSensorState OBJECT-TYPE + SYNTAX SensorStateEnumeration + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The most critical sensor state during this measurement period." + ::= { circuitPoleSensorLogEntry 3 } + +logCircuitPoleSensorAvgValue OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The average sensor reading for the log period as an unsigned integer. + The value of this OID variable should be scaled by + inletSensorDecimalDigits. For example, if the value is 1 and + inletSensorDecimalDigits is 2, then actual value is 0.01. + This value will wrap around if the scaled sensor reading exceeds + 4294967295. It is undefined for sensors which can have negative + readings. + This object does not apply to sensors without numerical reading." + ::= { circuitPoleSensorLogEntry 4 } + +logCircuitPoleSensorMaxValue OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The maximum sensor reading for the log period as an unsigned integer. + The value of this OID variable should be scaled by + inletSensorDecimalDigits. For example, if the value is 1 and + inletSensorDecimalDigits is 2, then actual value is 0.01. + This value will wrap around if the scaled sensor reading exceeds + 4294967295. It is undefined for sensors which can have negative + readings. + This object does not apply to sensors without numerical reading." + ::= { circuitPoleSensorLogEntry 5 } + +logCircuitPoleSensorMinValue OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The minimum sensor reading for the log period as an unsigned integer. + The value of this OID variable should be scaled by + inletSensorDecimalDigits. For example, if the value is 1 and + inletSensorDecimalDigits is 2, then actual value is 0.01. + This value will wrap around if the scaled sensor reading exceeds + 4294967295. It is undefined for sensors which can have negative + readings. + This object does not apply to sensors without numerical reading." + ::= { circuitPoleSensorLogEntry 6 } + +logCircuitPoleSensorSignedAvgValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The average sensor reading for the log period as a signed integer. + The value of this OID variable should be scaled by + inletSensorDecimalDigits. For example, if the value is 1 and + inletSensorDecimalDigits is 2, then actual value is 0.01. + This value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This object does not apply to sensors without numerical reading." + ::= { circuitPoleSensorLogEntry 7 } + +logCircuitPoleSensorSignedMaxValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The maximum sensor reading for the log period as a signed integer. + The value of this OID variable should be scaled by + inletSensorDecimalDigits. For example, if the value is 1 and + inletSensorDecimalDigits is 2, then actual value is 0.01. + This value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This object does not apply to sensors without numerical reading." + ::= { circuitPoleSensorLogEntry 8 } + +logCircuitPoleSensorSignedMinValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The minimum sensor reading for the log period as a signed integer. + The value of this OID variable should be scaled by + inletSensorDecimalDigits. For example, if the value is 1 and + inletSensorDecimalDigits is 2, then actual value is 0.01. + This value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This object does not apply to sensors without numerical reading." + ::= { circuitPoleSensorLogEntry 9 } + +-- unitSensorMeasurementsTable: unit-level sensor readings + +unitSensorMeasurementsTable OBJECT-TYPE + SYNTAX SEQUENCE OF UnitSensorMeasurementsEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of unit sensor entries." + ::= { measurementsUnit 3 } + +unitSensorMeasurementsEntry OBJECT-TYPE + SYNTAX UnitSensorMeasurementsEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing measurement objects for an unit sensor." + INDEX { pduId, sensorType } + ::= { unitSensorMeasurementsTable 1 } UnitSensorMeasurementsEntryStruct ::= SEQUENCE { - measurementsUnitSensorIsAvailable TruthValue, - measurementsUnitSensorState SensorStateEnumeration, - measurementsUnitSensorValue Unsigned32, - measurementsUnitSensorTimeStamp Unsigned32, - measurementsUnitSensorSignedValue Integer32 - } + measurementsUnitSensorIsAvailable TruthValue, + measurementsUnitSensorState SensorStateEnumeration, + measurementsUnitSensorValue Unsigned32, + measurementsUnitSensorTimeStamp Unsigned32, + measurementsUnitSensorSignedValue Integer32 + } +measurementsUnitSensorIsAvailable OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Is the sensor available?" + ::= { unitSensorMeasurementsEntry 2 } +measurementsUnitSensorState OBJECT-TYPE + SYNTAX SensorStateEnumeration + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The sensor state." + ::= { unitSensorMeasurementsEntry 3 } -measurementsUnitSensorIsAvailable OBJECT-TYPE - SYNTAX TruthValue - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "Is the sensor available?" - ::= { unitSensorMeasurementsEntry 2 } +measurementsUnitSensorValue OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The sensor reading as an unsigned integer. + The value of this OID variable should be scaled by + unitSensorDecimalDigits. For example, if the value is 1 and + unitSensorDecimalDigits is 2, then actual value is 0.01. + This value will wrap around if the scaled sensor reading exceeds + 4294967295. It is undefined for sensors which can have negative + readings. + This parameter does not apply to sensors without numerical reading." + ::= { unitSensorMeasurementsEntry 4 } +measurementsUnitSensorTimeStamp OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The timestamp." + ::= { unitSensorMeasurementsEntry 5 } +measurementsUnitSensorSignedValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The sensor reading as a signed integer. + The value of this OID variable should be scaled by + unitSensorDecimalDigits. For example, if the value is 1 and + unitSensorDecimalDigits is 2, then actual value is 0.01. + This value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { unitSensorMeasurementsEntry 6 } -measurementsUnitSensorState OBJECT-TYPE - SYNTAX SensorStateEnumeration - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The sensor state." - ::= { unitSensorMeasurementsEntry 3 } +-- inletSensorMeasurementsTable: inlet sensor readings -measurementsUnitSensorValue OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The sensor reading as an unsigned integer. - The value of this OID variable should be scaled by - unitSensorDecimalDigits. For example, if the value is 1 and - unitSensorDecimalDigits is 2, then actual value is 0.01. - This value will wrap around if the scaled sensor reading exceeds - 4294967295. It is undefined for sensors which can have negative - readings. - This parameter does not apply to sensors without numerical reading, - e.g. power supply status sensors." - ::= { unitSensorMeasurementsEntry 4 } +inletSensorMeasurementsTable OBJECT-TYPE + SYNTAX SEQUENCE OF InletSensorMeasurementsEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of inlet sensor entries." + ::= { measurementsInlet 3 } -measurementsUnitSensorTimeStamp OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The timestamp." - ::= { unitSensorMeasurementsEntry 5 } - -measurementsUnitSensorSignedValue OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The sensor reading as a signed integer. - The value of this OID variable should be scaled by - unitSensorDecimalDigits. For example, if the value is 1 and - unitSensorDecimalDigits is 2, then actual value is 0.01. - This value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647). - This parameter does not apply to sensors without numerical reading, - e.g. power supply status sensors." - ::= { unitSensorMeasurementsEntry 6 } - - - --- The inletSensorMeasurementsTable - -inletSensorMeasurementsTable OBJECT-TYPE - SYNTAX SEQUENCE OF InletSensorMeasurementsEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A list of inlet sensor entries. The number of - entries is given by the value of inletCount for the PDU." - ::= { measurementsInlet 3 } - -inletSensorMeasurementsEntry OBJECT-TYPE - SYNTAX InletSensorMeasurementsEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "An entry containing measurement objects for an inlet sensor." - INDEX { pduId, inletId, sensorType } - ::= { inletSensorMeasurementsTable 1 } +inletSensorMeasurementsEntry OBJECT-TYPE + SYNTAX InletSensorMeasurementsEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing measurement objects for an inlet sensor." + INDEX { pduId, inletId, sensorType } + ::= { inletSensorMeasurementsTable 1 } InletSensorMeasurementsEntryStruct ::= SEQUENCE { - measurementsInletSensorIsAvailable TruthValue, - measurementsInletSensorState SensorStateEnumeration, - measurementsInletSensorValue Unsigned32, - measurementsInletSensorTimeStamp Unsigned32, - measurementsInletSensorSignedValue Integer32 - } + measurementsInletSensorIsAvailable TruthValue, + measurementsInletSensorState SensorStateEnumeration, + measurementsInletSensorValue Unsigned32, + measurementsInletSensorTimeStamp Unsigned32, + measurementsInletSensorSignedValue Integer32 + } -measurementsInletSensorIsAvailable OBJECT-TYPE - SYNTAX TruthValue - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "Is the sensor available?" - ::= { inletSensorMeasurementsEntry 2 } +measurementsInletSensorIsAvailable OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Is the sensor available?" + ::= { inletSensorMeasurementsEntry 2 } -measurementsInletSensorState OBJECT-TYPE - SYNTAX SensorStateEnumeration - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The sensor state." - ::= { inletSensorMeasurementsEntry 3 } +measurementsInletSensorState OBJECT-TYPE + SYNTAX SensorStateEnumeration + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The sensor state." + ::= { inletSensorMeasurementsEntry 3 } -measurementsInletSensorValue OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The sensor reading as an unsigned integer. - The value of this OID variable should be scaled by - inletSensorDecimalDigits. For example, if the value is 1 and - inletSensorDecimalDigits is 2, then actual value is 0.01. - This value will wrap around if the scaled sensor reading exceeds - 4294967295. It is undefined for sensors which can have negative - readings. - This parameter does not apply to sensors without numerical reading, - e.g. surge protector status sensors." - ::= { inletSensorMeasurementsEntry 4 } +measurementsInletSensorValue OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The sensor reading as an unsigned integer. + The value of this OID variable should be scaled by + inletSensorDecimalDigits. For example, if the value is 1 and + inletSensorDecimalDigits is 2, then actual value is 0.01. + This value will wrap around if the scaled sensor reading exceeds + 4294967295. It is undefined for sensors which can have negative + readings. + This parameter does not apply to sensors without numerical reading." + ::= { inletSensorMeasurementsEntry 4 } -measurementsInletSensorTimeStamp OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The timestamp." - ::= { inletSensorMeasurementsEntry 5 } +measurementsInletSensorTimeStamp OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The timestamp." + ::= { inletSensorMeasurementsEntry 5 } -measurementsInletSensorSignedValue OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The sensor reading as a signed integer. - The value of this OID variable should be scaled by - inletSensorDecimalDigits. For example, if the value is 1 and - inletSensorDecimalDigits is 2, then actual value is 0.01. - This value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647). - This parameter does not apply to sensors without numerical reading, - e.g. surge protector status sensors." - ::= { inletSensorMeasurementsEntry 6 } +measurementsInletSensorSignedValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The sensor reading as a signed integer. + The value of this OID variable should be scaled by + inletSensorDecimalDigits. For example, if the value is 1 and + inletSensorDecimalDigits is 2, then actual value is 0.01. + This value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { inletSensorMeasurementsEntry 6 } +-- inletPoleSensorMeasurementsTable: inlet pole sensor readings +inletPoleSensorMeasurementsTable OBJECT-TYPE + SYNTAX SEQUENCE OF InletPoleSensorMeasurementsEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of inlet pole sensor entries." + ::= { measurementsInlet 4 } --- The inletPoleSensorMeasurementsTable - -inletPoleSensorMeasurementsTable OBJECT-TYPE - SYNTAX SEQUENCE OF InletPoleSensorMeasurementsEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A list of inletPole sensor entries. The number of - entries is given by the value of inletPoleCount for the inlet." - ::= { measurementsInlet 4 } - -inletPoleSensorMeasurementsEntry OBJECT-TYPE - SYNTAX InletPoleSensorMeasurementsEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "An entry containing measurement objects for an inletPole sensor." - INDEX { pduId, inletId, inletPoleIndex,sensorType } - ::= { inletPoleSensorMeasurementsTable 1 } +inletPoleSensorMeasurementsEntry OBJECT-TYPE + SYNTAX InletPoleSensorMeasurementsEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing measurement objects for an inlet pole sensor." + INDEX { pduId, inletId, inletPoleIndex, sensorType } + ::= { inletPoleSensorMeasurementsTable 1 } InletPoleSensorMeasurementsEntryStruct ::= SEQUENCE { - measurementsInletPoleSensorIsAvailable TruthValue, - measurementsInletPoleSensorState SensorStateEnumeration, - measurementsInletPoleSensorValue Unsigned32, - measurementsInletPoleSensorTimeStamp Unsigned32, - measurementsInletPoleSensorSignedValue Integer32 - } - + measurementsInletPoleSensorIsAvailable TruthValue, + measurementsInletPoleSensorState SensorStateEnumeration, + measurementsInletPoleSensorValue Unsigned32, + measurementsInletPoleSensorTimeStamp Unsigned32, + measurementsInletPoleSensorSignedValue Integer32 + } measurementsInletPoleSensorIsAvailable OBJECT-TYPE - SYNTAX TruthValue - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "Is the sensor available?" - ::= { inletPoleSensorMeasurementsEntry 2 } + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Is the sensor available?" + ::= { inletPoleSensorMeasurementsEntry 2 } -measurementsInletPoleSensorState OBJECT-TYPE - SYNTAX SensorStateEnumeration - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The sensor state." - ::= { inletPoleSensorMeasurementsEntry 3 } +measurementsInletPoleSensorState OBJECT-TYPE + SYNTAX SensorStateEnumeration + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The sensor state." + ::= { inletPoleSensorMeasurementsEntry 3 } -measurementsInletPoleSensorValue OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The sensor reading as an unsigned integer. - The value of this OID variable should be scaled by - inletPoleSensorDecimalDigits. For example, if the value is 1 and - inletPoleSensorDecimalDigits is 2, then actual value is 0.01. - This value will wrap around if the scaled sensor reading exceeds - 4294967295. It is undefined for sensors which can have negative - readings. - This parameter does not apply to sensors without numerical reading." - ::= { inletPoleSensorMeasurementsEntry 4 } +measurementsInletPoleSensorValue OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The sensor reading as an unsigned integer. + The value of this OID variable should be scaled by + inletPoleSensorDecimalDigits. For example, if the value is 1 and + inletPoleSensorDecimalDigits is 2, then actual value is 0.01. + This value will wrap around if the scaled sensor reading exceeds + 4294967295. It is undefined for sensors which can have negative + readings. + This parameter does not apply to sensors without numerical reading." + ::= { inletPoleSensorMeasurementsEntry 4 } -measurementsInletPoleSensorTimeStamp OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The timestamp." - ::= { inletPoleSensorMeasurementsEntry 5 } +measurementsInletPoleSensorTimeStamp OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The timestamp." + ::= { inletPoleSensorMeasurementsEntry 5 } measurementsInletPoleSensorSignedValue OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The sensor reading as a signed integer. - The value of this OID variable should be scaled by - inletPoleSensorDecimalDigits. For example, if the value is 1 and - inletPoleSensorDecimalDigits is 2, then actual value is 0.01. - This value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647). - This parameter does not apply to sensors without numerical reading." - ::= { inletPoleSensorMeasurementsEntry 6 } + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The sensor reading as a signed integer. + The value of this OID variable should be scaled by + inletPoleSensorDecimalDigits. For example, if the value is 1 and + inletPoleSensorDecimalDigits is 2, then actual value is 0.01. + This value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { inletPoleSensorMeasurementsEntry 6 } +-- outletSensorMeasurementsTable: outlet sensor readings +outletSensorMeasurementsTable OBJECT-TYPE + SYNTAX SEQUENCE OF OutletSensorMeasurementsEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of outlet sensor entries." + ::= { measurementsOutlet 3 } --- The outletSensorMeasurementsTable - -outletSensorMeasurementsTable OBJECT-TYPE - SYNTAX SEQUENCE OF OutletSensorMeasurementsEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A list of outlet sensor entries. The number of - entries is given by the value of outletCount for the PDU." - ::= { measurementsOutlet 3 } - -outletSensorMeasurementsEntry OBJECT-TYPE - SYNTAX OutletSensorMeasurementsEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "An entry containing measurement objects for an outlet sensor." - INDEX { pduId, outletId, sensorType } - ::= { outletSensorMeasurementsTable 1 } +outletSensorMeasurementsEntry OBJECT-TYPE + SYNTAX OutletSensorMeasurementsEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing measurement objects for an outlet sensor." + INDEX { pduId, outletId, sensorType } + ::= { outletSensorMeasurementsTable 1 } OutletSensorMeasurementsEntryStruct ::= SEQUENCE { - measurementsOutletSensorIsAvailable TruthValue, - measurementsOutletSensorState SensorStateEnumeration, - measurementsOutletSensorValue Unsigned32, - measurementsOutletSensorTimeStamp Unsigned32, - measurementsOutletSensorSignedValue Integer32 - } + measurementsOutletSensorIsAvailable TruthValue, + measurementsOutletSensorState SensorStateEnumeration, + measurementsOutletSensorValue Unsigned32, + measurementsOutletSensorTimeStamp Unsigned32, + measurementsOutletSensorSignedValue Integer32 + } -measurementsOutletSensorIsAvailable OBJECT-TYPE - SYNTAX TruthValue - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "Is the sensor available?" - ::= { outletSensorMeasurementsEntry 2 } +measurementsOutletSensorIsAvailable OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Is the sensor available?" + ::= { outletSensorMeasurementsEntry 2 } -measurementsOutletSensorState OBJECT-TYPE - SYNTAX SensorStateEnumeration - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The sensor state." - ::= { outletSensorMeasurementsEntry 3 } +measurementsOutletSensorState OBJECT-TYPE + SYNTAX SensorStateEnumeration + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The sensor state." + ::= { outletSensorMeasurementsEntry 3 } -measurementsOutletSensorValue OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The sensor reading as an unsigned integer. - The value of this OID variable should be scaled by - outletSensorDecimalDigits. For example, if the value is 1 and - outletSensorDecimalDigits is 2, then actual value is 0.01. - This value will wrap around if the scaled sensor reading exceeds - 4294967295. It is undefined for sensors which can have negative - readings. - This parameter does not apply to sensors without numerical reading, - e.g. outlet state sensors." - ::= { outletSensorMeasurementsEntry 4 } +measurementsOutletSensorValue OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The sensor reading as an unsigned integer. + The value of this OID variable should be scaled by + outletSensorDecimalDigits. For example, if the value is 1 and + outletSensorDecimalDigits is 2, then actual value is 0.01. + This value will wrap around if the scaled sensor reading exceeds + 4294967295. It is undefined for sensors which can have negative + readings. + This parameter does not apply to sensors without numerical reading." + ::= { outletSensorMeasurementsEntry 4 } -measurementsOutletSensorTimeStamp OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The timestamp." - ::= { outletSensorMeasurementsEntry 5 } +measurementsOutletSensorTimeStamp OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The timestamp." + ::= { outletSensorMeasurementsEntry 5 } -measurementsOutletSensorSignedValue OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The sensor reading as a signed integer. - The value of this OID variable should be scaled by - outletSensorDecimalDigits. For example, if the value is 1 and - outletSensorDecimalDigits is 2, then actual value is 0.01. - This value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647). - This parameter does not apply to sensors without numerical reading, - e.g. outlet state sensors." - ::= { outletSensorMeasurementsEntry 6 } +measurementsOutletSensorSignedValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The sensor reading as a signed integer. + The value of this OID variable should be scaled by + outletSensorDecimalDigits. For example, if the value is 1 and + outletSensorDecimalDigits is 2, then actual value is 0.01. + This value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { outletSensorMeasurementsEntry 6 } +-- outletPoleSensorMeasurementsTable: outlet pole sensor readings +outletPoleSensorMeasurementsTable OBJECT-TYPE + SYNTAX SEQUENCE OF OutletPoleSensorMeasurementsEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of outlet pole sensor entries." + ::= { measurementsOutlet 4 } --- The outletPoleSensorMeasurementsTable - -outletPoleSensorMeasurementsTable OBJECT-TYPE - SYNTAX SEQUENCE OF OutletPoleSensorMeasurementsEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A list of outletPole sensor entries. The number of - entries is given by the value of outletPoletCount for the outlet." - ::= { measurementsOutlet 4 } - -outletPoleSensorMeasurementsEntry OBJECT-TYPE - SYNTAX OutletPoleSensorMeasurementsEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "An entry containing measurement objects for an outletPole sensor." - INDEX { pduId, outletId, outletPoleIndex,sensorType } - ::= { outletPoleSensorMeasurementsTable 1 } +outletPoleSensorMeasurementsEntry OBJECT-TYPE + SYNTAX OutletPoleSensorMeasurementsEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing measurement objects for an outlet pole sensor." + INDEX { pduId, outletId, outletPoleIndex, sensorType } + ::= { outletPoleSensorMeasurementsTable 1 } OutletPoleSensorMeasurementsEntryStruct ::= SEQUENCE { - measurementsOutletPoleSensorIsAvailable TruthValue, - measurementsOutletPoleSensorState SensorStateEnumeration, - measurementsOutletPoleSensorValue Unsigned32, - measurementsOutletPoleSensorTimeStamp Unsigned32, - measurementsOutletPoleSensorSignedValue Integer32 - } + measurementsOutletPoleSensorIsAvailable TruthValue, + measurementsOutletPoleSensorState SensorStateEnumeration, + measurementsOutletPoleSensorValue Unsigned32, + measurementsOutletPoleSensorTimeStamp Unsigned32, + measurementsOutletPoleSensorSignedValue Integer32 + } measurementsOutletPoleSensorIsAvailable OBJECT-TYPE - SYNTAX TruthValue - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "Is the sensor available?" - ::= { outletPoleSensorMeasurementsEntry 2 } + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Is the sensor available?" + ::= { outletPoleSensorMeasurementsEntry 2 } -measurementsOutletPoleSensorState OBJECT-TYPE - SYNTAX SensorStateEnumeration - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The sensor state." - ::= { outletPoleSensorMeasurementsEntry 3 } +measurementsOutletPoleSensorState OBJECT-TYPE + SYNTAX SensorStateEnumeration + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The sensor state." + ::= { outletPoleSensorMeasurementsEntry 3 } -measurementsOutletPoleSensorValue OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The sensor reading as an unsigned integer. - The value of this OID variable should be scaled by - outletPoleSensorDecimalDigits. For example, if the value is 50 and - outletPoleSensorDecimalDigits is 2, then actual value is 0.05. - This value will wrap around if the scaled sensor reading exceeds - 4294967295. It is undefined for sensors which can have negative - readings. - This parameter does not apply to sensors without numerical reading." - ::= { outletPoleSensorMeasurementsEntry 4 } +measurementsOutletPoleSensorValue OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The sensor reading as an unsigned integer. + The value of this OID variable should be scaled by + outletPoleSensorDecimalDigits. For example, if the value is 1 and + outletPoleSensorDecimalDigits is 2, then actual value is 0.01. + This value will wrap around if the scaled sensor reading exceeds + 4294967295. It is undefined for sensors which can have negative + readings. + This parameter does not apply to sensors without numerical reading." + ::= { outletPoleSensorMeasurementsEntry 4 } measurementsOutletPoleSensorTimeStamp OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The timestamp." - ::= { outletPoleSensorMeasurementsEntry 5 } + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The timestamp." + ::= { outletPoleSensorMeasurementsEntry 5 } measurementsOutletPoleSensorSignedValue OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The sensor reading as a signed integer. - The value of this OID variable should be scaled by - outletPoleSensorDecimalDigits. For example, if the value is 50 and - outletPoleSensorDecimalDigits is 2, then actual value is 0.05. - This value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647). - This parameter does not apply to sensors without numerical reading." - ::= { outletPoleSensorMeasurementsEntry 6 } + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The sensor reading as a signed integer. + The value of this OID variable should be scaled by + outletPoleSensorDecimalDigits. For example, if the value is 1 and + outletPoleSensorDecimalDigits is 2, then actual value is 0.01. + This value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { outletPoleSensorMeasurementsEntry 6 } +-- overCurrentProtectorSensorMeasurementsTable: overcurrent protector sensor readings +overCurrentProtectorSensorMeasurementsTable OBJECT-TYPE + SYNTAX SEQUENCE OF OverCurrentProtectorSensorMeasurementsEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of overcurrent protector sensor entries." + ::= { measurementsOverCurrentProtector 3 } --- The overCurrentProtectorSensorMeasurementsTable - -overCurrentProtectorSensorMeasurementsTable OBJECT-TYPE - SYNTAX SEQUENCE OF OverCurrentProtectorSensorMeasurementsEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A list of overCurrentProtector sensor entries. The number of - entries is given by the value of overCurrentProtectorCount for the PDU." - ::= { measurementsOverCurrentProtector 3 } - -overCurrentProtectorSensorMeasurementsEntry OBJECT-TYPE - SYNTAX OverCurrentProtectorSensorMeasurementsEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "An entry containing measurement objects for an overCurrentProtector." - INDEX { pduId, overCurrentProtectorIndex, sensorType } - ::= { overCurrentProtectorSensorMeasurementsTable 1 } +overCurrentProtectorSensorMeasurementsEntry OBJECT-TYPE + SYNTAX OverCurrentProtectorSensorMeasurementsEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing measurement objects for an overcurrent protector sensor." + INDEX { pduId, overCurrentProtectorIndex, sensorType } + ::= { overCurrentProtectorSensorMeasurementsTable 1 } OverCurrentProtectorSensorMeasurementsEntryStruct ::= SEQUENCE { - measurementsOverCurrentProtectorSensorIsAvailable TruthValue, - measurementsOverCurrentProtectorSensorState SensorStateEnumeration, - measurementsOverCurrentProtectorSensorValue Unsigned32, - measurementsOverCurrentProtectorSensorTimeStamp Unsigned32, - measurementsOverCurrentProtectorSensorSignedValue Integer32 - } - + measurementsOverCurrentProtectorSensorIsAvailable TruthValue, + measurementsOverCurrentProtectorSensorState SensorStateEnumeration, + measurementsOverCurrentProtectorSensorValue Unsigned32, + measurementsOverCurrentProtectorSensorTimeStamp Unsigned32, + measurementsOverCurrentProtectorSensorSignedValue Integer32 + } measurementsOverCurrentProtectorSensorIsAvailable OBJECT-TYPE - SYNTAX TruthValue - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "Is the sensor available?" - ::= { overCurrentProtectorSensorMeasurementsEntry 2 } + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Is the sensor available?" + ::= { overCurrentProtectorSensorMeasurementsEntry 2 } measurementsOverCurrentProtectorSensorState OBJECT-TYPE - SYNTAX SensorStateEnumeration - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The sensor state." - ::= { overCurrentProtectorSensorMeasurementsEntry 3 } + SYNTAX SensorStateEnumeration + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The sensor state." + ::= { overCurrentProtectorSensorMeasurementsEntry 3 } measurementsOverCurrentProtectorSensorValue OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The sensor reading as an unsigned integer. - The value of this OID variable should be scaled by - overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and - overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01. - This value will wrap around if the scaled sensor reading exceeds - 4294967295. It is undefined for sensors which can have negative - readings. - This parameter does not apply to sensors without numerical reading, - e.g. trip sensors." - ::= { overCurrentProtectorSensorMeasurementsEntry 4 } + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The sensor reading as an unsigned integer. + The value of this OID variable should be scaled by + overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and + overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01. + This value will wrap around if the scaled sensor reading exceeds + 4294967295. It is undefined for sensors which can have negative + readings. + This parameter does not apply to sensors without numerical reading." + ::= { overCurrentProtectorSensorMeasurementsEntry 4 } measurementsOverCurrentProtectorSensorTimeStamp OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The timestamp." - ::= { overCurrentProtectorSensorMeasurementsEntry 5 } + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The timestamp." + ::= { overCurrentProtectorSensorMeasurementsEntry 5 } measurementsOverCurrentProtectorSensorSignedValue OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The sensor reading as a signed integer. - The value of this OID variable should be scaled by - overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and - overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01. - This value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647). - This parameter does not apply to sensors without numerical reading, - e.g. trip sensors." - ::= { overCurrentProtectorSensorMeasurementsEntry 6 } + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The sensor reading as a signed integer. + The value of this OID variable should be scaled by + overCurrentProtectorSensorDecimalDigits. For example, if the value is 1 and + overCurrentProtectorSensorDecimalDigits is 2, then actual value is 0.01. + This value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { overCurrentProtectorSensorMeasurementsEntry 6 } +-- externalSensorMeasurementsTable: external sensor readings +externalSensorMeasurementsTable OBJECT-TYPE + SYNTAX SEQUENCE OF ExternalSensorMeasurementsEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of external sensor entries. The number of + entries is given by the value of externalSensorCount + for the PDU." + ::= { measurementsExternalSensor 3 } --- The externalSensorMeasurementsTable - -externalSensorMeasurementsTable OBJECT-TYPE - SYNTAX SEQUENCE OF ExternalSensorMeasurementsEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A list of external sensor entries. The number of - entries is given by the value of externalSensorCount for the PDU." - ::= { measurementsExternalSensor 3 } - -externalSensorMeasurementsEntry OBJECT-TYPE - SYNTAX ExternalSensorMeasurementsEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "An entry containing measurement objects for an external sensor." - INDEX { pduId, sensorID } - ::= { externalSensorMeasurementsTable 1 } +externalSensorMeasurementsEntry OBJECT-TYPE + SYNTAX ExternalSensorMeasurementsEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing measurement objects for an external sensor." + INDEX { pduId, sensorID } + ::= { externalSensorMeasurementsTable 1 } ExternalSensorMeasurementsEntryStruct ::= SEQUENCE { - measurementsExternalSensorIsAvailable TruthValue, - measurementsExternalSensorState SensorStateEnumeration, - measurementsExternalSensorValue Integer32, - measurementsExternalSensorTimeStamp Unsigned32 - } + measurementsExternalSensorIsAvailable TruthValue, + measurementsExternalSensorState SensorStateEnumeration, + measurementsExternalSensorValue Integer32, + measurementsExternalSensorTimeStamp Unsigned32 + } +measurementsExternalSensorIsAvailable OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Is the sensor available?" + ::= { externalSensorMeasurementsEntry 2 } -measurementsExternalSensorIsAvailable OBJECT-TYPE - SYNTAX TruthValue - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "Is the sensor available?" - ::= { externalSensorMeasurementsEntry 2 } +measurementsExternalSensorState OBJECT-TYPE + SYNTAX SensorStateEnumeration + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The sensor state." + ::= { externalSensorMeasurementsEntry 3 } +measurementsExternalSensorValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The sensor reading as a signed integer. + The value of this OID variable should be scaled by + externalSensorDecimalDigits. For example, if the value is 1 and + externalSensorDecimalDigits is 2, then actual value is 0.01. + This parameter does not apply to sensors without numerical reading." + ::= { externalSensorMeasurementsEntry 4 } -measurementsExternalSensorState OBJECT-TYPE - SYNTAX SensorStateEnumeration - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The sensor state." - ::= { externalSensorMeasurementsEntry 3 } +measurementsExternalSensorTimeStamp OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The sensor reading timestamp." + ::= { externalSensorMeasurementsEntry 5 } -measurementsExternalSensorValue OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The sensor reading as a signed integer. - The value of this OID variable should be scaled by - externalSensorDecimalDigits. For example, if the value is 1 and - externalSensorDecimalDigits is 2, then actual value is 0.01. - This parameter does not apply to sensors without numerical reading, - e.g. contact closure or smoke detection sensors." - ::= { externalSensorMeasurementsEntry 4 } +-- wireSensorMeasurementsTable: wire sensor readings -measurementsExternalSensorTimeStamp OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The sensor reading timestamp." - ::= { externalSensorMeasurementsEntry 5 } +wireSensorMeasurementsTable OBJECT-TYPE + SYNTAX SEQUENCE OF WireSensorMeasurementsEntryStruct + MAX-ACCESS not-accessible + STATUS deprecated + DESCRIPTION + "A list of wire sensor entries. + Note: This feature is no longer used, the table is always empty." + ::= { measurementsWire 3 } - - --- The wireSensorMeasurementsTable - -wireSensorMeasurementsTable OBJECT-TYPE - SYNTAX SEQUENCE OF WireSensorMeasurementsEntryStruct - MAX-ACCESS not-accessible - STATUS deprecated - DESCRIPTION - "A list of wire sensor entries. The number of - entries is given by the value of wireCount for the PDU." - ::= { measurementsWire 3 } - -wireSensorMeasurementsEntry OBJECT-TYPE - SYNTAX WireSensorMeasurementsEntryStruct - MAX-ACCESS not-accessible - STATUS deprecated - DESCRIPTION - "An entry containing measurement objects for a wire." - INDEX { pduId, wireId, sensorType } - ::= { wireSensorMeasurementsTable 1 } +wireSensorMeasurementsEntry OBJECT-TYPE + SYNTAX WireSensorMeasurementsEntryStruct + MAX-ACCESS not-accessible + STATUS deprecated + DESCRIPTION + "An entry containing measurement objects for a wire." + INDEX { pduId, wireId, sensorType } + ::= { wireSensorMeasurementsTable 1 } WireSensorMeasurementsEntryStruct ::= SEQUENCE { - measurementsWireSensorIsAvailable TruthValue, - measurementsWireSensorState SensorStateEnumeration, - measurementsWireSensorValue Unsigned32, - measurementsWireSensorTimeStamp Unsigned32 - } + measurementsWireSensorIsAvailable TruthValue, + measurementsWireSensorState SensorStateEnumeration, + measurementsWireSensorValue Unsigned32, + measurementsWireSensorTimeStamp Unsigned32 + } -measurementsWireSensorIsAvailable OBJECT-TYPE - SYNTAX TruthValue - MAX-ACCESS read-only - STATUS deprecated - DESCRIPTION - "Is the sensor available?" - ::= { wireSensorMeasurementsEntry 2 } +measurementsWireSensorIsAvailable OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "Is the sensor available?" + ::= { wireSensorMeasurementsEntry 2 } -measurementsWireSensorState OBJECT-TYPE - SYNTAX SensorStateEnumeration - MAX-ACCESS read-only - STATUS deprecated - DESCRIPTION - "The sensor state." - ::= { wireSensorMeasurementsEntry 3 } +measurementsWireSensorState OBJECT-TYPE + SYNTAX SensorStateEnumeration + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The sensor state." + ::= { wireSensorMeasurementsEntry 3 } -measurementsWireSensorValue OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS deprecated - DESCRIPTION - "The sensor value. - The value of this OID variable should be scaled by - wireSensorDecimalDigits. For example, if the value is 1 and - wireSensorDecimalDigits is 2, then actual value is 0.01. - This value will wrap around if the value exceeds 4294967295 - This parameter does not apply to sensors without numerical reading." - ::= { wireSensorMeasurementsEntry 4 } +measurementsWireSensorValue OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The sensor value. + The value of this OID variable should be scaled by + wireSensorDecimalDigits. For example, if the value is 1 and + wireSensorDecimalDigits is 2, then actual value is 0.01. + This value will wrap around if the value exceeds 4294967295 + This parameter does not apply to sensors without numerical reading." + ::= { wireSensorMeasurementsEntry 4 } -measurementsWireSensorTimeStamp OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS deprecated - DESCRIPTION - "The timestamp." - ::= { wireSensorMeasurementsEntry 5 } +measurementsWireSensorTimeStamp OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS deprecated + DESCRIPTION + "The timestamp." + ::= { wireSensorMeasurementsEntry 5 } +-- transferSwitchSensorMeasurementsTable: transfer switch sensor readings +transferSwitchSensorMeasurementsTable OBJECT-TYPE + SYNTAX SEQUENCE OF TransferSwitchSensorMeasurementsEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of transfer switch sensor entries." + ::= { measurementsTransferSwitch 3 } - - - --- The transfer switch SensorMeasurementsTable - -transferSwitchSensorMeasurementsTable OBJECT-TYPE - SYNTAX SEQUENCE OF TransferSwitchSensorMeasurementsEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A list of transfer switch sensor entries. The number of - entries is given by the value of transferSwitchCount for the PDU." - ::= { measurementsTransferSwitch 3 } - -transferSwitchSensorMeasurementsEntry OBJECT-TYPE - SYNTAX TransferSwitchSensorMeasurementsEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "An entry containing measurement objects for a transfer switch." - INDEX { pduId, transferSwitchId, sensorType } - ::= { transferSwitchSensorMeasurementsTable 1 } +transferSwitchSensorMeasurementsEntry OBJECT-TYPE + SYNTAX TransferSwitchSensorMeasurementsEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing measurement objects for a transfer switch sensor." + INDEX { pduId, transferSwitchId, sensorType } + ::= { transferSwitchSensorMeasurementsTable 1 } TransferSwitchSensorMeasurementsEntryStruct ::= SEQUENCE { - measurementsTransferSwitchSensorIsAvailable TruthValue, - measurementsTransferSwitchSensorState SensorStateEnumeration, - measurementsTransferSwitchSensorValue Unsigned32, - measurementsTransferSwitchSensorTimeStamp Unsigned32, - measurementsTransferSwitchSensorSignedValue Integer32 - } + measurementsTransferSwitchSensorIsAvailable TruthValue, + measurementsTransferSwitchSensorState SensorStateEnumeration, + measurementsTransferSwitchSensorValue Unsigned32, + measurementsTransferSwitchSensorTimeStamp Unsigned32, + measurementsTransferSwitchSensorSignedValue Integer32 + } -measurementsTransferSwitchSensorIsAvailable OBJECT-TYPE - SYNTAX TruthValue - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "Is the sensor available?" - ::= { transferSwitchSensorMeasurementsEntry 2 } +measurementsTransferSwitchSensorIsAvailable OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Is the sensor available?" + ::= { transferSwitchSensorMeasurementsEntry 2 } -measurementsTransferSwitchSensorState OBJECT-TYPE - SYNTAX SensorStateEnumeration - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The sensor state." - ::= { transferSwitchSensorMeasurementsEntry 3 } +measurementsTransferSwitchSensorState OBJECT-TYPE + SYNTAX SensorStateEnumeration + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The sensor state." + ::= { transferSwitchSensorMeasurementsEntry 3 } measurementsTransferSwitchSensorValue OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The sensor reading as an unsigned integer. - The value of this OID variable should be scaled by - transferSwitchSensorDecimalDigits. For example, if the value is 1 and - transferSwitchSensorDecimalDigits is 2, then actual value is 0.01. - This value will wrap around if the scaled sensor reading exceeds - 4294967295. It is undefined for sensors which can have negative - readings. - This parameter does not apply to sensors without numerical reading, - e.g. operational state or switch fault sensors." - ::= { transferSwitchSensorMeasurementsEntry 4 } + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The sensor reading as an unsigned integer. + The value of this OID variable should be scaled by + transferSwitchSensorDecimalDigits. For example, if the value is 1 and + transferSwitchSensorDecimalDigits is 2, then actual value is 0.01. + This value will wrap around if the scaled sensor reading exceeds + 4294967295. It is undefined for sensors which can have negative + readings. + This parameter does not apply to sensors without numerical reading." + ::= { transferSwitchSensorMeasurementsEntry 4 } -measurementsTransferSwitchSensorTimeStamp OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The timestamp." - ::= { transferSwitchSensorMeasurementsEntry 5 } +measurementsTransferSwitchSensorTimeStamp OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The timestamp." + ::= { transferSwitchSensorMeasurementsEntry 5 } -measurementsTransferSwitchSensorSignedValue OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The sensor reading as a signed integer. - The value of this OID variable should be scaled by - transferSwitchSensorDecimalDigits. For example, if the value is 1 and - transferSwitchSensorDecimalDigits is 2, then actual value is 0.01. - This value is undefined for sensors whose range exceeds the - Integer32 range (-2147483648 .. 2147483647). - This parameter does not apply to sensors without numerical reading, - e.g. operational state or switch fault sensors." - ::= { transferSwitchSensorMeasurementsEntry 6 } +measurementsTransferSwitchSensorSignedValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The sensor reading as a signed integer. + The value of this OID variable should be scaled by + transferSwitchSensorDecimalDigits. For example, if the value is 1 and + transferSwitchSensorDecimalDigits is 2, then actual value is 0.01. + This value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { transferSwitchSensorMeasurementsEntry 6 } +-- circuitSensorMeasurementsTable: BCM2/PMC branch circuit sensor readings +circuitSensorMeasurementsTable OBJECT-TYPE + SYNTAX SEQUENCE OF CircuitSensorMeasurementsEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of circuit sensor entries." + ::= { measurementsCircuit 3 } --- the OutletSwitchControlTable +circuitSensorMeasurementsEntry OBJECT-TYPE + SYNTAX CircuitSensorMeasurementsEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing measurement objects for a circuit sensor." + INDEX { pduId, circuitId, sensorType } + ::= { circuitSensorMeasurementsTable 1 } --- The OutletSwitchControl table implements switching of outlets. +CircuitSensorMeasurementsEntryStruct ::= SEQUENCE { + measurementsCircuitSensorIsAvailable TruthValue, + measurementsCircuitSensorState SensorStateEnumeration, + measurementsCircuitSensorValue Unsigned32, + measurementsCircuitSensorTimeStamp Unsigned32, + measurementsCircuitSensorSignedValue Integer32 + } +measurementsCircuitSensorIsAvailable OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Is the sensor available?" + ::= { circuitSensorMeasurementsEntry 2 } -outletSwitchControlTable OBJECT-TYPE - SYNTAX SEQUENCE OF OutletSwitchControlEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A list of outlets for a PDU. The number of - entries is given by the value of outletCount." - ::= { outletControl 2 } +measurementsCircuitSensorState OBJECT-TYPE + SYNTAX SensorStateEnumeration + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The sensor state." + ::= { circuitSensorMeasurementsEntry 3 } -outletSwitchControlEntry OBJECT-TYPE - SYNTAX OutletSwitchControlEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "An entry for implementing switching operations on an outlet." - INDEX { pduId, outletId } - ::= { outletSwitchControlTable 1 } +measurementsCircuitSensorValue OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The sensor reading as an unsigned integer. + The value of this OID variable should be scaled by + inletSensorDecimalDigits. For example, if the value is 1 and + inletSensorDecimalDigits is 2, then actual value is 0.01. + This value will wrap around if the scaled sensor reading exceeds + 4294967295. It is undefined for sensors which can have negative + readings. + This parameter does not apply to sensors without numerical reading." + ::= { circuitSensorMeasurementsEntry 4 } -OutletSwitchControlEntryStruct ::= SEQUENCE { - switchingOperation OutletSwitchingOperationsEnumeration, - outletSwitchingState SensorStateEnumeration, - outletSwitchingTimeStamp Unsigned32 - } +measurementsCircuitSensorTimeStamp OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The timestamp." + ::= { circuitSensorMeasurementsEntry 5 } +measurementsCircuitSensorSignedValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The sensor reading as a signed integer. + The value of this OID variable should be scaled by + inletSensorDecimalDigits. For example, if the value is 1 and + inletSensorDecimalDigits is 2, then actual value is 0.01. + This value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { circuitSensorMeasurementsEntry 6 } +-- circuitPoleSensorMeasurementsTable: BCM2/PMC circuit pole sensor readings -switchingOperation OBJECT-TYPE - SYNTAX OutletSwitchingOperationsEnumeration - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The switching operation." - ::= { outletSwitchControlEntry 2 } +circuitPoleSensorMeasurementsTable OBJECT-TYPE + SYNTAX SEQUENCE OF CircuitPoleSensorMeasurementsEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of panel circuit pole sensor entries." + ::= { measurementsCircuit 4 } +circuitPoleSensorMeasurementsEntry OBJECT-TYPE + SYNTAX CircuitPoleSensorMeasurementsEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing measurement objects for a circuit pole sensor." + INDEX { pduId, circuitId, circuitPoleId, sensorType } + ::= { circuitPoleSensorMeasurementsTable 1 } -outletSwitchingState OBJECT-TYPE - SYNTAX SensorStateEnumeration - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The outlet state at present" - ::= { outletSwitchControlEntry 3 } +CircuitPoleSensorMeasurementsEntryStruct ::= SEQUENCE { + measurementsCircuitPoleSensorIsAvailable TruthValue, + measurementsCircuitPoleSensorState SensorStateEnumeration, + measurementsCircuitPoleSensorValue Unsigned32, + measurementsCircuitPoleSensorTimeStamp Unsigned32, + measurementsCircuitPoleSensorSignedValue Integer32 + } +measurementsCircuitPoleSensorIsAvailable OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Is the sensor available?" + ::= { circuitPoleSensorMeasurementsEntry 2 } -outletSwitchingTimeStamp OBJECT-TYPE - SYNTAX Unsigned32 - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The timestamp indicating when the outlet was last switched" - ::= { outletSwitchControlEntry 4 } +measurementsCircuitPoleSensorState OBJECT-TYPE + SYNTAX SensorStateEnumeration + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The sensor state." + ::= { circuitPoleSensorMeasurementsEntry 3 } +measurementsCircuitPoleSensorValue OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The sensor reading as an unsigned integer. + The value of this OID variable should be scaled by + inletSensorDecimalDigits. For example, if the value is 1 and + inletSensorDecimalDigits is 2, then actual value is 0.01. + This value will wrap around if the scaled sensor reading exceeds + 4294967295. It is undefined for sensors which can have negative + readings. + This parameter does not apply to sensors without numerical reading." + ::= { circuitPoleSensorMeasurementsEntry 4 } --- the transferSwitchControlTable +measurementsCircuitPoleSensorTimeStamp OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The timestamp." + ::= { circuitPoleSensorMeasurementsEntry 5 } --- The TransferSwitchControl table implements control operations of transfer switches. +measurementsCircuitPoleSensorSignedValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The sensor reading as a signed integer. + The value of this OID variable should be scaled by + inletSensorDecimalDigits. For example, if the value is 1 and + inletSensorDecimalDigits is 2, then actual value is 0.01. + This value is undefined for sensors whose range exceeds the + Integer32 range (-2147483648 .. 2147483647). + This parameter does not apply to sensors without numerical reading." + ::= { circuitPoleSensorMeasurementsEntry 6 } +-- outletSwitchControlTable: objects for controlling outlets -transferSwitchControlTable OBJECT-TYPE - SYNTAX SEQUENCE OF TransferSwitchControlEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A list of transfer switches for a PDU. The number of - entries is given by the value of transferSwitchCount." - ::= { transferSwitchControl 1 } +outletSwitchControlTable OBJECT-TYPE + SYNTAX SEQUENCE OF OutletSwitchControlEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of outlets for a PDU. The number of + entries is given by the value of outletCount." + ::= { outletControl 2 } -transferSwitchControlEntry OBJECT-TYPE - SYNTAX TransferSwitchControlEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "An entry for implementing switching operations on a transfer switch." - INDEX { pduId, transferSwitchId } - ::= { transferSwitchControlTable 1 } +outletSwitchControlEntry OBJECT-TYPE + SYNTAX OutletSwitchControlEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry for implementing switching operations on an outlet." + INDEX { pduId, outletId } + ::= { outletSwitchControlTable 1 } + +OutletSwitchControlEntryStruct ::= SEQUENCE { + switchingOperation OutletSwitchingOperationsEnumeration, + outletSwitchingState SensorStateEnumeration, + outletSwitchingTimeStamp Unsigned32 + } + +switchingOperation OBJECT-TYPE + SYNTAX OutletSwitchingOperationsEnumeration + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The switching operation: switch on, switch off or power-cycle." + ::= { outletSwitchControlEntry 2 } + +outletSwitchingState OBJECT-TYPE + SYNTAX SensorStateEnumeration + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The outlet state at present" + ::= { outletSwitchControlEntry 3 } + +outletSwitchingTimeStamp OBJECT-TYPE + SYNTAX Unsigned32 + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The timestamp indicating when the outlet was last switched" + ::= { outletSwitchControlEntry 4 } + +-- transferSwitchControlTable: objects for controlling transfer switches + +transferSwitchControlTable OBJECT-TYPE + SYNTAX SEQUENCE OF TransferSwitchControlEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of transfer switches for a PDU. The number of + entries is given by the value of transferSwitchCount." + ::= { transferSwitchControl 1 } + +transferSwitchControlEntry OBJECT-TYPE + SYNTAX TransferSwitchControlEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry for implementing switching operations on a transfer switch." + INDEX { pduId, transferSwitchId } + ::= { transferSwitchControlTable 1 } TransferSwitchControlEntryStruct ::= SEQUENCE { - transferSwitchActiveInlet Integer32, - transferSwitchTransferToInlet Integer32, - transferSwitchAlarmOverride TruthValue, - transferSwitchLastTransferReason TransferSwitchTransferReasonEnumeration - } + transferSwitchActiveInlet Integer32, + transferSwitchTransferToInlet Integer32, + transferSwitchAlarmOverride TruthValue, + transferSwitchLastTransferReason TransferSwitchTransferReasonEnumeration + } -transferSwitchActiveInlet OBJECT-TYPE - SYNTAX Integer32(1..64) - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The index of the currently active inlet." - ::= { transferSwitchControlEntry 1 } +transferSwitchActiveInlet OBJECT-TYPE + SYNTAX Integer32(1..64) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The index of the currently active inlet." + ::= { transferSwitchControlEntry 1 } -transferSwitchTransferToInlet OBJECT-TYPE - SYNTAX Integer32(1..64) - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "Select the active inlet. If the new inlet is available, it will become - both active and preferred, otherwise an inconsistentValue error will - be returned. - By default the switching operation will fail if the phase difference - between the inlets is too large. In this case the switch can be forced - by writing transferSwitchAlarmOverride as True in the same request. - This variable will always read as 0." - ::= { transferSwitchControlEntry 2 } +transferSwitchTransferToInlet OBJECT-TYPE + SYNTAX Integer32(1..64) + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Select the active inlet. If the new inlet is available, it will become + both active and preferred, otherwise an inconsistentValue error will + be returned. + By default the switching operation will fail if the phase difference + between the inlets is too large. In this case the switch can be forced + by writing transferSwitchAlarmOverride as True in the same request. + This variable will always read as 0." + ::= { transferSwitchControlEntry 2 } -transferSwitchAlarmOverride OBJECT-TYPE - SYNTAX TruthValue - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "Force transfer even if the phase difference between the inlets is too - large. - This may only be written together with transferSwitchTransferToInlet, - otherwise an inconsistentValue error will be returned. Always reads as - false." - ::= { transferSwitchControlEntry 3 } +transferSwitchAlarmOverride OBJECT-TYPE + SYNTAX TruthValue + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Force transfer even if the phase difference between the inlets is too + large. + This may only be written together with transferSwitchTransferToInlet, + otherwise an inconsistentValue error will be returned. Always reads as + false." + ::= { transferSwitchControlEntry 3 } transferSwitchLastTransferReason OBJECT-TYPE - SYNTAX TransferSwitchTransferReasonEnumeration - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The reason for the most recent transfer" - ::= { transferSwitchControlEntry 4 } + SYNTAX TransferSwitchTransferReasonEnumeration + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The reason for the most recent transfer" + ::= { transferSwitchControlEntry 4 } +-- actuatorControlTable: objects for controlling peripheral actuators - -- the actuatorControlTable +actuatorControlTable OBJECT-TYPE + SYNTAX SEQUENCE OF ActuatorControlEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of actuators for a PDU. " + ::= { actuatorControl 2 } --- The actuatorControl table implements user-initiated state changes for an actuator. +actuatorControlEntry OBJECT-TYPE + SYNTAX ActuatorControlEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry for implementing user-initiated state changes for an actuator." + INDEX { pduId, sensorID } + ::= { actuatorControlTable 1 } +ActuatorControlEntryStruct ::= SEQUENCE { + actuatorState SensorStateEnumeration + } -actuatorControlTable OBJECT-TYPE - SYNTAX SEQUENCE OF ActuatorControlEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A list of actuators for a PDU. " - ::= { actuatorControl 2 } +actuatorState OBJECT-TYPE + SYNTAX SensorStateEnumeration + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The actuator state. + A get operation retrieves the state of the actuator. + A set operation changes the state of the sensor. + The valid states for set operations are on(7) and off(8). + Attempting to set the state to any other value will generate an error." + ::= { actuatorControlEntry 2 } -actuatorControlEntry OBJECT-TYPE - SYNTAX ActuatorControlEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "An entry for implementing user-initiated state changes for an actuator." - INDEX { pduId, sensorID } - ::= { actuatorControlTable 1 } +-- rcmSelfTestTable: objects for controlling RCM (residual current) sensors -ActuatorControlEntryStruct ::= SEQUENCE { - actuatorState SensorStateEnumeration - } +rcmSelfTestTable OBJECT-TYPE + SYNTAX SEQUENCE OF RcmSelfTestEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of RCMs." + ::= { rcmControl 2 } +rcmSelfTestEntry OBJECT-TYPE + SYNTAX RcmSelfTestEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry for initiating the self test of an RCM." + INDEX { pduId, inletId } + ::= { rcmSelfTestTable 1 } +RcmSelfTestEntryStruct ::= SEQUENCE { + rcmState SensorStateEnumeration + } +rcmState OBJECT-TYPE + SYNTAX SensorStateEnumeration + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "The rcm state. + A Get operation retrieves the state of the RCM State Sensor. + A Set operation changes the state of the sensor. + The only valid state for set operations is selfTest(29). + When rcmState is set to selfTest, self test of the RCM starts. + Attempting to set the state to any other value will generate an error. + If the current state is selfTest, then an attempt to set the value to selfTest + will be ignored." + ::= { rcmSelfTestEntry 2 } -actuatorState OBJECT-TYPE - SYNTAX SensorStateEnumeration - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The actuator state. - A Get operation retrieves the state of the actuator. - A Set operation changes the stae of the sensor. - The valid states for set operations are on and Off. - Attempting to set the state to any other value will generate an error. " - ::= { actuatorControlEntry 2 } +-- inletSensorControlTable: objects for controlling inlet sensors +inletSensorControlTable OBJECT-TYPE + SYNTAX SEQUENCE OF InletSensorControlEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of control entries for the inlet sensors of a PDU. The set + of valid indices is defined by the value of inletCount and the + inletDeviceCapabilities entry for the selected inlet." + ::= { inletSensorControl 1 } --- the RCM (Residual Control Monitor) Self Test Table - --- The rcmSelfTest table implements self test of the RCM. - - -rcmSelfTestTable OBJECT-TYPE - SYNTAX SEQUENCE OF RcmSelfTestEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A list of RCMs. " - ::= { rcmControl 2 } - -rcmSelfTestEntry OBJECT-TYPE - SYNTAX RcmSelfTestEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "An entry for implementing self test of an RCM." - INDEX { pduId, inletId } - ::= { rcmSelfTestTable 1 } - -RcmSelfTestEntryStruct ::= SEQUENCE { - rcmState SensorStateEnumeration - } - - - - -rcmState OBJECT-TYPE - SYNTAX SensorStateEnumeration - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "The rcm state. - A Get operation retrieves the state of the RCM State Sensor. - A Set operation changes the state of the sensor. - The valid state for set operations is selfTest. - When rcmState is set to selfTest, self test of the RCM starts. - Attempting to set the state to any other value will generate an error. - If the current state is selfTest, then an attempt to set the value to selfTest - will be ignored. - - " - ::= { rcmSelfTestEntry 2 } - - --- the InletSensorControlTable - --- The InletSensorControl table implements operations on inlet sensors - -inletSensorControlTable OBJECT-TYPE - SYNTAX SEQUENCE OF InletSensorControlEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A list of control entries for the inlet sensors of a PDU. The set - of valid indexes is defined by the value of inletCount and the - inletDeviceCapabilities entry for the selected inlet." - ::= { inletSensorControl 1 } - -inletSensorControlEntry OBJECT-TYPE - SYNTAX InletSensorControlEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "An entry used for controlling an inlet sensor." - INDEX { pduId, inletId, sensorType } - ::= { inletSensorControlTable 1 } +inletSensorControlEntry OBJECT-TYPE + SYNTAX InletSensorControlEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry used for controlling an inlet sensor." + INDEX { pduId, inletId, sensorType } + ::= { inletSensorControlTable 1 } InletSensorControlEntryStruct ::= SEQUENCE { - inletSensorResetValue Integer32 - } + inletSensorResetValue Integer32 + } -inletSensorResetValue OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "Writing to this variable sets a new value for the addressed sensor. Only - accumulating sensors (e.g. energy counters) can be reset, and currently - the only supported value is 0. Writing any other value returns an error. - This variable will always read as 0." - ::= { inletSensorControlEntry 1 } +inletSensorResetValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Writing to this variable sets a new value for the addressed sensor. Only + accumulating sensors (e.g. energy counters) can be reset, and currently + the only supported value is 0. Writing any other value returns an error. + This variable will always read as 0." + ::= { inletSensorControlEntry 1 } +-- outletSensorControlTable: objects for controlling outlet sensors --- the OutletSensorControlTable +outletSensorControlTable OBJECT-TYPE + SYNTAX SEQUENCE OF OutletSensorControlEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of control entries for the outlet sensors of a PDU. The set + of valid indices is defined by the value of outletCount and the + outletDeviceCapabilities entry for the selected outlet." + ::= { outletSensorControl 1 } --- The OutletSensorControl table implements operations on outlet sensors - -outletSensorControlTable OBJECT-TYPE - SYNTAX SEQUENCE OF OutletSensorControlEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A list of control entries for the outlet sensors of a PDU. The set - of valid indexes is defined by the value of outletCount and the - outletDeviceCapabilities entry for the selected outlet." - ::= { outletSensorControl 1 } - -outletSensorControlEntry OBJECT-TYPE - SYNTAX OutletSensorControlEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "An entry used for controlling an outlet sensor." - INDEX { pduId, outletId, sensorType } - ::= { outletSensorControlTable 1 } +outletSensorControlEntry OBJECT-TYPE + SYNTAX OutletSensorControlEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry used for controlling an outlet sensor." + INDEX { pduId, outletId, sensorType } + ::= { outletSensorControlTable 1 } OutletSensorControlEntryStruct ::= SEQUENCE { - outletSensorResetValue Integer32 - } + outletSensorResetValue Integer32 + } -outletSensorResetValue OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "Writing to this variable sets a new value for the addressed sensor. Only - accumulating sensors (e.g. energy counters) can be reset, and currently - the only supported value is 0. Writing any other value returns an error. - This variable will always read as 0." - ::= { outletSensorControlEntry 1 } +outletSensorResetValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Writing to this variable sets a new value for the addressed sensor. Only + accumulating sensors (e.g. energy counters) can be reset, and currently + the only supported value is 0. Writing any other value returns an error. + This variable will always read as 0." + ::= { outletSensorControlEntry 1 } --- the UnitSensorControlTable +-- unitSensorControlTable: objects for controlling unit sensors --- The UnitSensorControl table implements operations on pdu sensors +unitSensorControlTable OBJECT-TYPE + SYNTAX SEQUENCE OF UnitSensorControlEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of control entries for the global sensors of a PDU. The set + of valid indices is defined by the value of pduCount and the + pduDeviceCapabilities entry." + ::= { unitSensorControl 1 } -unitSensorControlTable OBJECT-TYPE - SYNTAX SEQUENCE OF UnitSensorControlEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A list of control entries for the global sensors of a PDU. The set - of valid indexes is defined by the value of pduCount and the - pduDeviceCapabilities entry." - ::= { unitSensorControl 1 } - -unitSensorControlEntry OBJECT-TYPE - SYNTAX UnitSensorControlEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "An entry used for controlling an global sensor." - INDEX { pduId, sensorType } - ::= { unitSensorControlTable 1 } +unitSensorControlEntry OBJECT-TYPE + SYNTAX UnitSensorControlEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry used for controlling an global sensor." + INDEX { pduId, sensorType } + ::= { unitSensorControlTable 1 } UnitSensorControlEntryStruct ::= SEQUENCE { - unitSensorResetValue Integer32 - } + unitSensorResetValue Integer32 + } -unitSensorResetValue OBJECT-TYPE - SYNTAX Integer32 - MAX-ACCESS read-write - STATUS current - DESCRIPTION - "Writing to this variable sets a new value for the addressed sensor. Only - accumulating sensors (e.g. energy counters) can be reset, and currently - the only supported value is 0. Writing any other value returns an error. - This variable will always read as 0." - ::= { unitSensorControlEntry 1 } +unitSensorResetValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Writing to this variable sets a new value for the addressed sensor. Only + accumulating sensors (e.g. energy counters) can be reset, and currently + the only supported value is 0. Writing any other value returns an error. + This variable will always read as 0. + This object applies only to multi-inlet PDUs." + ::= { unitSensorControlEntry 1 } --- the ReliabilityData table +-- circuitSensorControlTable: objects for controlling BCM2/PMC circuit sensors --- The ReliabilityData table contains reliability data for the PDU. +circuitSensorControlTable OBJECT-TYPE + SYNTAX SEQUENCE OF CircuitSensorControlEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of control entries for the circuit sensors of a BCM2. The maximum + number of entries is given by the value of panelCircuitPositionCount." + ::= { circuitSensorControl 1 } +circuitSensorControlEntry OBJECT-TYPE + SYNTAX CircuitSensorControlEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry used for controlling an circuit sensor." + INDEX { pduId, circuitId, sensorType } + ::= { circuitSensorControlTable 1 } -reliabilityDataTableSequenceNumber OBJECT-TYPE - SYNTAX Integer32(1..2147483647) - MAX-ACCESS read-only - STATUS current - DESCRIPTION - "The sequence number for updates to the reliability data table" - ::= { reliabilityData 1 } +CircuitSensorControlEntryStruct ::= SEQUENCE { + circuitSensorResetValue Integer32 + } +circuitSensorResetValue OBJECT-TYPE + SYNTAX Integer32 + MAX-ACCESS read-write + STATUS current + DESCRIPTION + "Writing to this variable sets a new value for the addressed sensor. Only + accumulating sensors (e.g. energy counters) can be reset, and currently + the only supported value is 0. Writing any other value returns an error. + This variable will always read as 0." + ::= { circuitSensorControlEntry 1 } -reliabilityDataTable OBJECT-TYPE - SYNTAX SEQUENCE OF ReliabilityDataEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "A list of PDU reliability data entries." - ::= { reliabilityData 2 } +-- reliabilityData table: PDU reliability data -reliabilityDataEntry OBJECT-TYPE - SYNTAX ReliabilityDataEntryStruct - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "An entry containing reliability data for a particular PDU." - INDEX { reliabilityIndex } - ::= { reliabilityDataTable 1 } +reliabilityDataTableSequenceNumber OBJECT-TYPE + SYNTAX Integer32(1..2147483647) + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "The sequence number for updates to the reliability data table" + ::= { reliabilityData 1 } + +reliabilityDataTable OBJECT-TYPE + SYNTAX SEQUENCE OF ReliabilityDataEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "A list of PDU reliability data entries." + ::= { reliabilityData 2 } + +reliabilityDataEntry OBJECT-TYPE + SYNTAX ReliabilityDataEntryStruct + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "An entry containing reliability data for a particular PDU." + INDEX { reliabilityIndex } + ::= { reliabilityDataTable 1 } ReliabilityDataEntryStruct ::= SEQUENCE { - reliabilityIndex Integer32, - reliabilityId DisplayString, - reliabilityDataValue Unsigned32, - reliabilityDataMaxPossible Unsigned32, - reliabilityDataWorstValue Unsigned32, - reliabilityDataThreshold Unsigned32, - reliabilityDataRawUpperBytes Unsigned32, - reliabilityDataRawLowerBytes Unsigned32, - reliabilityDataFlags BITS - } + reliabilityIndex Integer32, + reliabilityId DisplayString, + reliabilityDataValue Unsigned32, + reliabilityDataMaxPossible Unsigned32, + reliabilityDataWorstValue Unsigned32, + reliabilityDataThreshold Unsigned32, + reliabilityDataRawUpperBytes Unsigned32, + reliabilityDataRawLowerBytes Unsigned32, + reliabilityDataFlags BITS + } +reliabilityIndex OBJECT-TYPE + SYNTAX Integer32(1..4096) + MAX-ACCESS not-accessible + STATUS current + DESCRIPTION + "Index of the entry in the reliability data table." + ::= { reliabilityDataEntry 1 } +reliabilityId OBJECT-TYPE + SYNTAX DisplayString + MAX-ACCESS read-only + STATUS current + DESCRIPTION + "Unique ID of the entry. + POH + Power on hours. -reliabilityIndex OBJECT-TYPE - SYNTAX Integer32(1..4096) - MAX-ACCESS not-accessible - STATUS current - DESCRIPTION - "Index of the entry in the table." - ::= { reliabilityDataEntry 1 } + CB.