diff --git a/html/images/logos/alvarion.png b/html/images/logos/alvarion.png
new file mode 100644
index 0000000000..6f4c7bd9bd
Binary files /dev/null and b/html/images/logos/alvarion.png differ
diff --git a/html/images/os/alvarion.png b/html/images/os/alvarion.png
new file mode 100644
index 0000000000..cb9099ed11
Binary files /dev/null and b/html/images/os/alvarion.png differ
diff --git a/includes/definitions/breeze.yaml b/includes/definitions/breeze.yaml
new file mode 100644
index 0000000000..4820100196
--- /dev/null
+++ b/includes/definitions/breeze.yaml
@@ -0,0 +1,11 @@
+os: breeze
+text: Alvarion Breeze
+type: wireless
+icon: alvarion
+over:
+ - { graph: device_bits, text: 'Device Traffic' }
+mib_dir:
+ - alvarion
+discovery:
+ - sysObjectId:
+ - .1.3.6.1.4.1.12394.4.
\ No newline at end of file
diff --git a/includes/polling/os/breeze.inc.php b/includes/polling/os/breeze.inc.php
new file mode 100644
index 0000000000..40319a88a3
--- /dev/null
+++ b/includes/polling/os/breeze.inc.php
@@ -0,0 +1,26 @@
+.
+ *
+ * @package LibreNMS
+ * @link http://librenms.org
+ * @copyright 2017 Neil Lathwood
+ * @author Neil Lathwood
+ */
+
+$version = trim(snmp_get($device, 'brzaccVLRunningSoftwareVersion.0', '-Oqv', 'ALVARION-DOT11-WLAN-MIB'), '"');
diff --git a/mibs/alvarion/ALVARION-DOT11-WLAN-MIB b/mibs/alvarion/ALVARION-DOT11-WLAN-MIB
new file mode 100755
index 0000000000..ca595efacb
--- /dev/null
+++ b/mibs/alvarion/ALVARION-DOT11-WLAN-MIB
@@ -0,0 +1,6077 @@
+-- Title: ALVARION Private MIB
+-- This Private MIB supports BreezeAccess_VL, BreezeACCESS_4900 and BreezeNET-B product lines.
+--
+--
+-- Version: 4.5.16
+-- Date: Tuesday August 14 2007
+-- Comments: ALVARION agents also support the following Public MIBs:
+
+-- This MIB supports BreezeACCESS VL products (AU and SU),
+-- BreezeACCESS 4900 (AU and SU) and
+-- BreezeNET-B products (BU and RB).
+
+-- Some MIB compilers require that the following lines
+-- for proper compilation
+
+--#include "rfc1155.smi"
+--#include "rfc1212.smi"
+
+
+-- mgmt OBJECT IDENTIFIER ::= { iso org(3) dod(6) internet(1) mgmt(2) }
+-- mib OBJECT IDENTIFIER ::= { mgmt 1 }
+-- directory OBJECT IDENTIFIER ::= { internet 1 }
+-- experimental OBJECT IDENTIFIER ::= { internet 3 }
+-- private OBJECT IDENTIFIER ::= { internet 4 }
+-- enterprises OBJECT IDENTIFIER ::= { private 1 }
+
+-- End of lines which might be needed to other MIB browsers
+-- for proper compilation
+
+
+ALVARION-DOT11-WLAN-MIB DEFINITIONS ::= BEGIN
+
+
+ IMPORTS
+ MODULE-IDENTITY, NOTIFICATION-TYPE, enterprises, IpAddress,Counter32,OBJECT-TYPE
+ FROM SNMPv2-SMI;
+
+alvarion OBJECT IDENTIFIER ::= { enterprises 12394 }
+products OBJECT IDENTIFIER ::= { alvarion 1 }
+
+breezeAccessVLMib MODULE-IDENTITY
+ LAST-UPDATED "0708141146Z"
+ ORGANIZATION "Alvarion Ltd."
+ CONTACT-INFO "Alvarion Customer Service
+ Postal: Alvarion Ltd.
+ Barzel 21
+ Tel Aviv 69710
+ ISRAEL
+ E-mail: CS_Coordinator@alvarion.com"
+ DESCRIPTION
+ "BreezeAccess VL, BreezeACCESS 4900 and BreezeNET-B"
+ REVISION "0708141146Z"
+ DESCRIPTION
+ "Version 4.5"
+ ::= { products 1 }
+
+
+MacAddress ::= OCTET STRING (SIZE(6))
+DisplayString ::= OCTET STRING
+
+alvarionOID OBJECT IDENTIFIER ::= { alvarion 4 }
+brzAccessVLOID OBJECT IDENTIFIER ::= { alvarionOID 1 }
+
+
+brzAccessVLAU OBJECT IDENTIFIER ::= { brzAccessVLOID 1 }
+brzAccessVLSU OBJECT IDENTIFIER ::= { brzAccessVLOID 2 }
+
+brzAccessVLAU-BS OBJECT IDENTIFIER ::= { brzAccessVLOID 4 }
+brzAccessVLAU-SA OBJECT IDENTIFIER ::= { brzAccessVLOID 5 }
+
+brzAccessVLAUS-BS OBJECT IDENTIFIER ::= { brzAccessVLOID 6 }
+brzAccessVLAUS-SA OBJECT IDENTIFIER ::= { brzAccessVLOID 7 }
+brzAccessAU-EZ OBJECT IDENTIFIER ::= { brzAccessVLOID 8 }
+
+brzAccessVLSU-6-1D OBJECT IDENTIFIER ::= { brzAccessVLOID 11 }
+brzAccessVLSU-6-BD OBJECT IDENTIFIER ::= { brzAccessVLOID 12 }
+brzAccessVLSU-24-BD OBJECT IDENTIFIER ::= { brzAccessVLOID 13 }
+brzAccessVLSU-BD OBJECT IDENTIFIER ::= { brzAccessVLOID 14 }
+brzAccessVLSU-54-BD OBJECT IDENTIFIER ::= { brzAccessVLOID 15 }
+
+brzAccessVLSU-3-1D OBJECT IDENTIFIER ::= { brzAccessVLOID 16 }
+brzAccessVLSU-3-4D OBJECT IDENTIFIER ::= { brzAccessVLOID 17 }
+brzAccessVLSU-I OBJECT IDENTIFIER ::= { brzAccessVLOID 18 }
+
+brzNetB-BU-B14 OBJECT IDENTIFIER ::= { brzAccessVLOID 21 }
+brzNetB-BU-B28 OBJECT IDENTIFIER ::= { brzAccessVLOID 22 }
+brzNetB-BU-B100 OBJECT IDENTIFIER ::= { brzAccessVLOID 23 }
+
+brzNetB-RB-B14 OBJECT IDENTIFIER ::= { brzAccessVLOID 31 }
+brzNetB-RB-B28 OBJECT IDENTIFIER ::= { brzAccessVLOID 32 }
+brzNetB-RB-B100 OBJECT IDENTIFIER ::= { brzAccessVLOID 33 }
+
+brzAccess4900-AU-BS OBJECT IDENTIFIER ::= { brzAccessVLOID 41 }
+brzAccess4900-AU-SA OBJECT IDENTIFIER ::= { brzAccessVLOID 42 }
+brzAccess4900-SU-BD OBJECT IDENTIFIER ::= { brzAccessVLOID 51 }
+
+brzAccessVLProducts OBJECT IDENTIFIER ::= { brzAccessVLOID 3 }
+
+-- ****************************************************************************************
+-- ****************************************************************************************
+-- General System Info
+-- ===================
+brzaccVLSysInfo OBJECT IDENTIFIER ::= {breezeAccessVLMib 1}
+
+
+ brzaccVLUnitHwVersion OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..32))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Hardware platform version."
+ ::= { brzaccVLSysInfo 1 }
+
+ brzaccVLRunningSoftwareVersion OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..32))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Running software version."
+ ::= { brzaccVLSysInfo 2 }
+
+ brzaccVLRunningFrom OBJECT-TYPE
+ SYNTAX INTEGER { mainVersion(1) , shadowVersion(2)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The memory (main or shadow) from which the current version is
+ running from."
+ ::= { brzaccVLSysInfo 3 }
+
+ brzaccVLMainVersionNumber OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..32))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Main software version number."
+ ::= { brzaccVLSysInfo 4 }
+
+ brzaccVLMainVersionFileName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..32))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Main software version file name."
+ ::= { brzaccVLSysInfo 5 }
+
+
+ brzaccVLShadowVersionNumber OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..32))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Shadow software version number."
+ ::= { brzaccVLSysInfo 6 }
+
+ brzaccVLShadowVersionFileName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..32))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Shadow software version file name."
+ ::= { brzaccVLSysInfo 7 }
+
+ brzaccVLUnitMacAddress OBJECT-TYPE
+ SYNTAX MacAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Unit hardware MAC address."
+ ::= { brzaccVLSysInfo 8 }
+
+ brzaccVLUnitType OBJECT-TYPE
+ SYNTAX INTEGER {auBS (1), auSA(2) , su-6-1D(3),su-6-BD(4),su-24-BD(5),
+ bu-B14(6),bu-B28(7),rb-B14(8),rb-B28(9),su-BD(10),su-54-BD (11),
+ su-3-1D(12),su-3-4D(13),ausBS(14),ausSA(15),
+ auBS4900(16),auSA4900(17),su4900(18), bu-B100(19), rb-B100(20), su-I(21),
+ au-E(22) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ auBS (1) : AU-BS (modular access unit).
+ auSA (2) : AU-SA (stand-alone access unit).
+ su-6-1D (3) : SU-6-1D (subscriber unit supporting 6 Mbps)
+ su-6-BD (4) : SU-6-BD (subscriber unit supporting 6 Mbps).
+ su-24-BD (5) : SU-24-BD (subscriber unit supporting 24 Mbps).
+ bu-B14 (6) : BU-B14 (BreezeNET Base Unit supporting 14 Mbps).
+ bu-B28 (7) : BU-B28 (BreezeNET Base Unit supporting 28 Mbps).
+ rb-B14 (8) : RB-B14 (BreezeNET Remote Bridge supporting 14 Mbps).
+ rb-B28 (9) : RB-B28 (BreezeNET Remote Bridge supporting 28 Mbps).
+ su-BD (10) : SU-BD (subscriber unit).
+ su-54-BD(11) : SU-54-BD (subscriber unit supporting 54 Mbps).
+ su-3-1D (12) : SU-3-1D (subscriber unit supporting 3 Mbps).
+ su-3-4D (13) : SU-3-4D (subscriber unit supporting 3 Mbps).
+ ausBS (14) : AUS-BS (modular access unit supporting maxim 8 or 25
+ (via licensing) subscribers and allowing association
+ only with SU-3 or SU-6).
+ ausSA (15) : AUS-SA (stand-alone access unit supporting maxim 8 or 25
+ (via licensing) subscribers and allowing association
+ only with SU-3 or SU-6 ).
+ auBS4900(16) : AU-BS-4900 (BreezeAccess 4900 modular access unit)
+ auSA4900(17) : AU-SA-4900 (BreezeAccess 4900 stand alone access unit)
+ suBD4900(18) : SU-BD-4900 (BreezeAccess 4900 subscriber unit)
+ bu-B100 (19) : BU-B100 (BreezeNET Base Unit unlimited throughput)
+ rb-B100 (20) : BU-B100 (BreezeNET Remote Bridge unlimited throughput)
+ su-I (21) : SU-I
+ au-E (22) : AU-E"
+ ::= { brzaccVLSysInfo 9 }
+
+ brzaccVLAssociatedAU OBJECT-TYPE
+ SYNTAX MacAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Associated AU/BU MAC address."
+ ::= { brzaccVLSysInfo 10 }
+
+ brzaccVLNumOfAssociationsSinceLastReset OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The number of associations since last reset, including
+ duplicate associations (re-associations)."
+ ::= { brzaccVLSysInfo 11 }
+
+ brzaccVLCurrentNumOfAssociations OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ Not applicable to BreezeNET-B products.
+ The number of SUs currently associated with the AU.
+ BreezeNET-B products return 65535."
+ ::= { brzaccVLSysInfo 13 }
+
+ brzaccVLUnitBootVersion OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..32))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Boot version."
+ ::= { brzaccVLSysInfo 14 }
+
+ brzaccVLRadioBand OBJECT-TYPE
+ SYNTAX INTEGER {band-5-8GHz (1), band-5-4GHz (2) , band-4-9GHz (3),band-5-2GHz (4),band-2-4GHz (5),band-5-3GHz (6),band-4-9GHzJapan (7)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The unit's radio band."
+ ::= { brzaccVLSysInfo 15 }
+
+ brzaccVLCurrentEthernetPortState OBJECT-TYPE
+ SYNTAX INTEGER { halfDuplexAnd10Mbps (1),
+ fullDuplexAnd10Mbps (2),
+ halfDuplexAnd100Mbps (3),
+ fullDuplexAnd100Mbps (4),
+ linkDown (5) }
+
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The current Ethernet port state."
+ ::= { brzaccVLSysInfo 16 }
+
+
+
+ brzaccVLTimeSinceLastReset OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..32))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The elapsed time since last reset."
+ ::= { brzaccVLSysInfo 17 }
+
+brzaccVLCountryDependentParameters OBJECT IDENTIFIER ::= {brzaccVLSysInfo 18}
+
+ brzaccVLCountryCode OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..32))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The country code and country name or country group name
+ that is supported by the unit."
+ ::= { brzaccVLCountryDependentParameters 1 }
+
+ brzaccVLCountryDependentParamsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BrzaccVLCountryDependentParameterEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. A table of country dependent parameters."
+ ::= {brzaccVLCountryDependentParameters 2}
+
+ brzaccVLCountryDependentParameterEntry OBJECT-TYPE
+ SYNTAX BrzaccVLCountryDependentParameterEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ An entry in the Country Dependent Parameters table."
+ INDEX { brzaccVLCountryDependentParameterTableIdx }
+ ::= { brzaccVLCountryDependentParamsTable 1 }
+
+ BrzaccVLCountryDependentParameterEntry ::= SEQUENCE {
+ brzaccVLCountryDependentParameterTableIdx INTEGER,
+ brzaccVLCountryDependentParameterFrequencies DisplayString,
+ brzaccVLAllowedBandwidth INTEGER,
+ brzaccVLRegulationMaxTxPowerAtAntennaPort INTEGER,
+ brzaccVLRegulationMaxEIRP INTEGER,
+ brzaccVLMinModulationLevel INTEGER,
+ brzaccVLMaxModulationLevel INTEGER,
+ brzaccVLBurstModeSupport INTEGER,
+ brzaccVLMaximumBurstDuration INTEGER,
+ brzaccVLDfsSupport INTEGER,
+ brzaccVLMinimumHwRevision INTEGER
+ }
+
+ brzaccVLCountryDependentParameterTableIdx OBJECT-TYPE
+ SYNTAX INTEGER (1..5)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The sub-band ID of the entry in the Country Dependent
+ Parameters table. Serves also as index for the table entry."
+ ::= { brzaccVLCountryDependentParameterEntry 1 }
+
+ brzaccVLCountryDependentParameterFrequencies OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The frequencies included in the applicable sub-band entry."
+ ::= { brzaccVLCountryDependentParameterEntry 2 }
+
+ brzaccVLAllowedBandwidth OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The bandwidth when using the applicable the sub-band."
+ ::= { brzaccVLCountryDependentParameterEntry 3 }
+
+ brzaccVLRegulationMaxTxPowerAtAntennaPort OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The maximum allowed Tx power when using the applicable sub-band.
+ A RegulationMaxTxPowerAtAntennaPort of 255, means no limit"
+ ::= { brzaccVLCountryDependentParameterEntry 4 }
+
+ brzaccVLRegulationMaxEIRP OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The maximum Tx EIRP
+ when using the applicable sub-band.
+ A Regulation Max EIRP of 0, means no limit."
+ ::= { brzaccVLCountryDependentParameterEntry 5 }
+
+
+ brzaccVLMinModulationLevel OBJECT-TYPE
+ SYNTAX INTEGER { level1 (1),
+ level2 (2),
+ level3 (3),
+ level4 (4),
+ level5 (5),
+ level6 (6),
+ level7 (7),
+ level8 (8)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The minimum supported modulation level."
+ ::= { brzaccVLCountryDependentParameterEntry 6 }
+
+ brzaccVLMaxModulationLevel OBJECT-TYPE
+ SYNTAX INTEGER { level1 (1),
+ level2 (2),
+ level3 (3),
+ level4 (4),
+ level5 (5),
+ level6 (6),
+ level7 (7),
+ level8 (8)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The maximum supported modulation level."
+ ::= { brzaccVLCountryDependentParameterEntry 7 }
+
+ brzaccVLBurstModeSupport OBJECT-TYPE
+ SYNTAX INTEGER {supported(1), notSupported(2)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The supported Burst Mode Option."
+ ::= { brzaccVLCountryDependentParameterEntry 8}
+
+ brzaccVLMaximumBurstDuration OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Applicable only if Burst Mode Option is supported.
+ The maximum supported burst duration."
+ ::= { brzaccVLCountryDependentParameterEntry 9}
+
+
+ brzaccVLDfsSupport OBJECT-TYPE
+ SYNTAX INTEGER {supported(1), notSupported(2)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ The supported Dfs Option."
+ ::= { brzaccVLCountryDependentParameterEntry 10}
+
+ brzaccVLMinimumHwRevision OBJECT-TYPE
+ SYNTAX INTEGER {hwRevisionA (1), hwRevisionB (2),
+ hwRevisionC (3), hwRevisionD (4),
+ hwRevisionE (5), na (255)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The Minimum HW Revision needed to support the country code."
+ ::= { brzaccVLCountryDependentParameterEntry 11}
+
+
+ brzaccVLAuthenticationEncryptionSupport OBJECT-TYPE
+ SYNTAX INTEGER {supported(1), notSupported(2)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The supported Authentication Encryption Option."
+ ::= { brzaccVLCountryDependentParameters 3 }
+
+ brzaccVLDataEncryptionSupport OBJECT-TYPE
+ SYNTAX INTEGER {supported(1), notSupported(2)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The supported Data Encryption Option."
+ ::= { brzaccVLCountryDependentParameters 4 }
+
+ brzaccVLAESEncryptionSupport OBJECT-TYPE
+ SYNTAX INTEGER {supported(1), notSupported(2)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The supported AES Encryption Option."
+ ::= { brzaccVLCountryDependentParameters 5 }
+
+ brzaccVLAntennaGainChange OBJECT-TYPE
+ SYNTAX INTEGER {supported(1), notSupported(2)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Indicates whether the Antenna Gain parameter is changeable or fixed."
+ ::= { brzaccVLSysInfo 19 }
+
+ brzaccVLAteTestResults OBJECT-TYPE
+ SYNTAX INTEGER { none(0), pass(1), fail(2) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Results of ATE Test "
+ ::= { brzaccVLSysInfo 20 }
+
+ brzaccVLSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..35))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Serial Number of the unit"
+ ::= { brzaccVLSysInfo 21 }
+
+-- Unit Control
+-- ============
+brzaccVLUnitControl OBJECT IDENTIFIER ::= {breezeAccessVLMib 2}
+
+ brzaccVLResetUnit OBJECT-TYPE
+ SYNTAX INTEGER { cancel (1), resetSystemNow (2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Resets the unit and applies new parameter values."
+ ::= { brzaccVLUnitControl 1 }
+
+
+ brzaccVLSetDefaults OBJECT-TYPE
+ SYNTAX INTEGER { noDefaultSettingRequested (0),
+ completeFactory (1),
+ partialFactory (2),
+ completeOperator (3),
+ partialOperator (4),
+ cancelCurrentPendingRequest(5) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Sets unit configuration to Defaults values after the
+ next reset.
+ noDefaultSettingRequested : Read-Only Option, no Default setting was Issued.
+ completeFactory : All parameters revert to Factory
+ Defaults values.
+ partialFactory : All parameters revert to Factory
+ Defaults values, except the parameters
+ required for maintaining wireless
+ connectivity.
+ completeOperator: All parameters revert to Operator
+ Defaults values.
+ partialOperator : All parameters revert to Operator
+ Defaults values, except the parameters
+ required for maintaining wireless
+ connectivity.
+ cancelCurrentPendingRequest : Default Setting request is cancelled."
+ ::= { brzaccVLUnitControl 2 }
+
+ brzaccVLUnitName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..32))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The unit name.
+ A string of up to 32 printable ASCII characters."
+ ::= { brzaccVLUnitControl 3 }
+
+ brzaccVLFlashMemoryControl OBJECT-TYPE
+ SYNTAX INTEGER { resetAndBootFromShadowVersion (1),
+ useRunningVersionAfterReset (2),cancel(3) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ resetAndBootFromShadowVersion : Activates the backup
+ version.
+ useRunningVersionAfterReset : The currently active
+ version will become the main
+ version and will be activated
+ after next reset."
+ ::= { brzaccVLUnitControl 4 }
+
+
+ brzaccVLTelnetLogoutTimer OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Time-out of management via Telnet program.
+ Automatic exit if the program is inactive for the
+ defined time.
+ Range: 1 to 999 (minutes)."
+ ::= { brzaccVLUnitControl 5 }
+
+ brzaccVLSaveCurrentConfigurationAsOperatorDefaults OBJECT-TYPE
+ SYNTAX INTEGER { saveAsDefaults (1),cancel(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Saves the current configuration as Operator Defaults.
+ Cannot be executed after requesting set defaults
+ and the unit was not reset."
+ ::= { brzaccVLUnitControl 6 }
+
+ brzaccVLExitTelnet OBJECT-TYPE
+ SYNTAX INTEGER { cancelOperation (1), exit (2)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Exit the management via Telnet program."
+ ::= { brzaccVLUnitControl 7 }
+
+brzaccVLUnitPasswords OBJECT IDENTIFIER ::= {brzaccVLUnitControl 8}
+
+ brzaccVLReadOnlyPassword OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(1..8))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The User (read only) password.
+ This is also the Read Community String.
+ Up to 8 printable ASCII characters."
+ ::= { brzaccVLUnitPasswords 1 }
+
+ brzaccVLInstallerPassword OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(1..8))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The Installer password.
+ Up to 8 printable ASCII characters."
+ ::= { brzaccVLUnitPasswords 2 }
+
+ brzaccVLAdminPassword OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(1..8))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The Administrator password. Accessible only with SNMP Write
+ Community String (administrator password).
+ Up to 8 printable ASCII characters."
+ ::= { brzaccVLUnitPasswords 3 }
+
+
+ brzaccVLEthernetNegotiationMode OBJECT-TYPE
+ SYNTAX INTEGER { force10MbpsAndHalfDuplex (1),
+ force10MbpsAndFullDuplex (2),
+ force100MbpsAndHalfDuplex (3),
+ force100MbpsAndFullDuplex (4),
+ autoNegotiationMode (5) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The speed/duplex mode of the Ethernet port."
+ ::= { brzaccVLUnitControl 9 }
+
+brzaccVLFTPParameters OBJECT IDENTIFIER ::= {brzaccVLUnitControl 10}
+
+brzaccVLFTPServerParams OBJECT IDENTIFIER ::= {brzaccVLFTPParameters 1}
+
+ brzaccVLFTPServerUserName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..18))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The user name to be used for access to the FTP server.
+ Accessible only with SNMP Write Community String
+ (administrator password)."
+ ::= { brzaccVLFTPServerParams 1 }
+
+ brzaccVLFTPServerPassword OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..18))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The password to be used for access to the FTP server.
+ Accessible only with SNMP Write Community String
+ (administrator password)."
+ ::= { brzaccVLFTPServerParams 2 }
+
+ brzaccVLFTPClientIPAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ For SW version higher than 4.0 this is read-only.
+ The IP address of the FTP stack in the unit."
+ ::= { brzaccVLFTPServerParams 3 }
+
+ brzaccVLFTPServerIpAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The IP address of the FTP server."
+ ::= { brzaccVLFTPServerParams 4 }
+
+ brzaccVLFTPClientMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The Mask of the FTP stack in the unit."
+ ::= { brzaccVLFTPServerParams 5 }
+
+
+ brzaccVLFTPGatewayIpAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The FTP Gateway address"
+ ::= { brzaccVLFTPServerParams 6 }
+
+
+brzaccVLFTPSwDownload OBJECT IDENTIFIER ::= {brzaccVLFTPParameters 2}
+
+ brzaccVLFTPSwFileName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(1..20))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The name of the SW file to be downloaded."
+ ::= { brzaccVLFTPSwDownload 1 }
+
+ brzaccVLFTPSwSourceDir OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..80))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The source directory of the required file in the FTP server.
+ Up to 80 printable ASCII characters.
+ Use dot (.) To clear field"
+ ::= { brzaccVLFTPSwDownload 2 }
+
+ brzaccVLFTPDownloadSwFile OBJECT-TYPE
+ SYNTAX INTEGER { downloadFile (1) , cancel (2)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Execution of the SW download operation"
+ ::= { brzaccVLFTPSwDownload 3 }
+
+brzaccVLConfigurationFileLoading OBJECT IDENTIFIER ::= {brzaccVLFTPParameters 3}
+
+ brzaccVLConfigurationFileName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(1..20))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The name of the configuration file to be downloaded/uploaded."
+ ::= { brzaccVLConfigurationFileLoading 1 }
+
+ brzaccVLOperatorDefaultsFileName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(1..20))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The name of the Operator Defaults file to be downloaded/uploaded"
+ ::= { brzaccVLConfigurationFileLoading 2 }
+
+ brzaccVLFTPConfigurationFileSourceDir OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..80))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The source directory of the required file in the FTP server.
+ Up to 80 printable ASCII characters.
+ Use dot (.) To clear field"
+ ::= { brzaccVLConfigurationFileLoading 3 }
+
+ brzaccVLExecuteFTPConfigurationFileLoading OBJECT-TYPE
+ SYNTAX INTEGER {executeFTPGetConfigurationFile (1), executeFTPPutConfigurationFile (2),
+ executeFTPGetOperatorDefaults (3) , executeFTPPutOperatorDefaults (4), cancel (5) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Execution of the file download/upload operation."
+ ::= { brzaccVLConfigurationFileLoading 4 }
+
+
+
+brzaccVLEventLogFileUploading OBJECT IDENTIFIER ::= {brzaccVLFTPParameters 4}
+
+ brzaccVLEventLogFileName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(1..20))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The name of the Event Log file to be uploaded."
+ ::= { brzaccVLEventLogFileUploading 1 }
+
+ brzaccVLEventLogDestinationDir OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..80))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The destination directory of the event log file.
+ Up to 80 printable ASCII characters.
+ Use dot (.) To clear field."
+ ::= { brzaccVLEventLogFileUploading 2 }
+
+ brzaccVLUploadEventLogFile OBJECT-TYPE
+ SYNTAX INTEGER { uploadFile (1) , cancel (2)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Execution of the event log upload operation."
+ ::= { brzaccVLEventLogFileUploading 3 }
+
+ brzaccVLLoadingStatus OBJECT-TYPE
+ SYNTAX INTEGER {inProcess (1), successful (2), failed (3)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The status of the last loading operation."
+ ::= { brzaccVLUnitControl 11 }
+
+brzaccVLEventLogFileParams OBJECT IDENTIFIER ::= {brzaccVLUnitControl 12}
+
+ brzaccVLEventLogPolicy OBJECT-TYPE
+ SYNTAX INTEGER {message (1), warning (2), error (3),fatal(4), logNone(5)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The lowest level event to be registered in the event log."
+ ::= { brzaccVLEventLogFileParams 1 }
+
+ brzaccVLEraseEventLog OBJECT-TYPE
+ SYNTAX INTEGER { eraseEventLog (1),cancel(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Erase the event log."
+ ::= { brzaccVLEventLogFileParams 2 }
+
+ brzaccVLSystemLocation OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..34))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The unit location."
+ ::= { brzaccVLUnitControl 13 }
+
+brzaccVLFeatureUpgrade OBJECT IDENTIFIER ::= {brzaccVLUnitControl 14}
+
+ brzaccVLFeatureUpgradeManually OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(32..64))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Upgrade unit to support new feature. Enter your license number
+ (32 to 64 hex digits)."
+ ::= { brzaccVLFeatureUpgrade 1 }
+
+ brzaccVLChangeUnitType OBJECT-TYPE
+ SYNTAX INTEGER { bu(1), rb(2), cancel(3) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable RB/BU only.
+ Change the unit type between BU and RB."
+ ::= { brzaccVLUnitControl 15 }
+
+ brzaccLighteAPWorkingMode OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ Change unit running mode: 0 - VL mode 1 - Mixed cell mode"
+ ::= { brzaccVLUnitControl 16 }
+
+
+-- Network Management Params
+-- =========================
+ brzaccVLNwMngParameters OBJECT IDENTIFIER ::= {breezeAccessVLMib 3}
+
+ brzaccVLAccessToNwMng OBJECT-TYPE
+ SYNTAX INTEGER { fromWirelessOnly (1),
+ fromEthernetOnly (2),
+ fromBothWirelessAndEthernet (3),
+ na (255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The port to be used for remote management."
+ ::= { brzaccVLNwMngParameters 1 }
+
+
+ brzaccVLNwMngFilter OBJECT-TYPE
+ SYNTAX INTEGER { disable (1),
+ activateOnEthernetPort (2),
+ activateOnWirelessPort (3),
+ activateOnBothWirelessAndEthernet (4),
+ na (255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Disables or enable on one of the ports, or on both
+ ports, IP address based filtering of management messages
+ (e.g. SNMP , Telnet , TFTP , DHCP)."
+ ::= { brzaccVLNwMngParameters 2 }
+
+
+
+
+ mngIpFilterTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF MngIpFilterEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ A Management IP Filter Table of up to 3 IP addresses
+ of devices that are authorized to access the unit
+ for management purposes."
+ ::= { brzaccVLNwMngParameters 3 }
+
+ mngIpFilterEntry OBJECT-TYPE
+ SYNTAX MngIpFilterEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ A Management IP Filter Table entry."
+ INDEX { brzaccVLNwMngIpTableIdx }
+ ::= { mngIpFilterTable 1 }
+
+ MngIpFilterEntry ::= SEQUENCE { brzaccVLNwMngIpAddress IpAddress,
+ brzaccVLNwMngIpTableIdx INTEGER }
+
+ brzaccVLNwMngIpAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ An IP address in the Management IP Filter Table."
+ ::= { mngIpFilterEntry 1 }
+
+ brzaccVLNwMngIpTableIdx OBJECT-TYPE
+ SYNTAX INTEGER (1..10)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ A table index for an entry in the Management IP Filter
+ Table."
+ ::= { mngIpFilterEntry 2 }
+
+
+ brzaccVLDeleteOneNwIpAddr OBJECT-TYPE
+ SYNTAX INTEGER (0 | 1..10 | 255)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ 0 - cancel operation.
+ 1..10 - Deletes a single selected entry from the Management IP
+ Filter Table."
+ ::= { brzaccVLNwMngParameters 4 }
+
+ brzaccVLDeleteAllNwIpAddrs OBJECT-TYPE
+ SYNTAX INTEGER { deleteAll (1), cancelOperation (2), na (255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Deletes all entries from the Management IP Filter Table."
+ ::= { brzaccVLNwMngParameters 5 }
+
+ brzaccVLAccessToNwTrap OBJECT-TYPE
+ SYNTAX INTEGER { disable(1), enable(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Enables or disables sending of traps."
+ ::= { brzaccVLNwMngParameters 6 }
+
+ mngTrapTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF MngTrapEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ A Management Trap Table of up to 10 IP addresses of
+ stations to send traps to."
+ ::= { brzaccVLNwMngParameters 7 }
+
+ mngTrapEntry OBJECT-TYPE
+ SYNTAX MngTrapEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ A Management Trap Table entry."
+ INDEX { brzaccVLNwTrapTableIdx }
+ ::= { mngTrapTable 1 }
+
+ MngTrapEntry ::= SEQUENCE { brzaccVLNwMngTrapCommunity DisplayString,
+ brzaccVLNwMngTrapAddress IpAddress,
+ brzaccVLNwTrapTableIdx INTEGER }
+
+ brzaccVLNwMngTrapCommunity OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..14))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The trap community associated with the applicable
+ entry in the Management Trap Table.
+ Up to 14 printable case sensitive ASCII characters."
+ ::= { mngTrapEntry 1 }
+
+ brzaccVLNwMngTrapAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ An IP address in the Management Trap Table entry."
+ ::= { mngTrapEntry 2 }
+
+ brzaccVLNwTrapTableIdx OBJECT-TYPE
+ SYNTAX INTEGER (1..10)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Tables Index for an entry in the Management Trap Table."
+ ::= { mngTrapEntry 3 }
+
+
+ brzaccVLDeleteOneTrapAddr OBJECT-TYPE
+ SYNTAX INTEGER (0 | 1..10 | 255)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ 0 - cancel operation.
+ 1..10 - Deletes a single selected entry from the Management
+ Trap Table."
+ ::= { brzaccVLNwMngParameters 8 }
+
+
+ brzaccVLDeleteAllTrapAddrs OBJECT-TYPE
+ SYNTAX INTEGER { deleteAll (1),cancelOperation (2), na (255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Deletes all entries from the Management Trap Table."
+ ::= { brzaccVLNwMngParameters 9 }
+
+ brzaccVLMngIpRangesTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BrzaccVLMngIpRangeEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Table of Management IP Address Ranges"
+ ::= { brzaccVLNwMngParameters 10 }
+
+ brzaccVLMngIpRangeEntry OBJECT-TYPE
+ SYNTAX BrzaccVLMngIpRangeEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ A Management IP Address Ranges Table entry"
+ INDEX { brzaccVLMngIpRangeIdx }
+ ::= { brzaccVLMngIpRangesTable 1 }
+
+ BrzaccVLMngIpRangeEntry ::= SEQUENCE {
+ brzaccVLMngIpRangeIdx INTEGER,
+ brzaccVLMngIpRangeFlag INTEGER,
+ brzaccVLMngIpRangeStart IpAddress,
+ brzaccVLMngIpRangeEnd IpAddress,
+ brzaccVLMngIpRangeMask IpAddress
+ }
+
+
+ brzaccVLMngIpRangeIdx OBJECT-TYPE
+ SYNTAX INTEGER (1..10)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Index of an entry in the Management IP Address Ranges Table"
+ ::= { brzaccVLMngIpRangeEntry 1 }
+
+ brzaccVLMngIpRangeFlag OBJECT-TYPE
+ SYNTAX INTEGER { rangeDefinedByStartEndAddr(1), rangeDefinedByStartAddrMask(2)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Defines the method of defining the range:
+ Using Start & End Address( rangeDefinedByStartEndAddr ),
+ or using Start Address and Mask ( rangeDefinedByStartAddrSubNetMask )."
+ ::= { brzaccVLMngIpRangeEntry 2 }
+
+
+ brzaccVLMngIpRangeStart OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Start Address of the range"
+ ::= { brzaccVLMngIpRangeEntry 3 }
+
+ brzaccVLMngIpRangeEnd OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ End Address of the range.
+ Used only if brzaccVLMngIpRangeFlag is rangeDefinedByStartEndAddr"
+ ::= { brzaccVLMngIpRangeEntry 4 }
+
+ brzaccVLMngIpRangeMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ End Address of the range.
+ Used only if brzaccVLMngIpRangeFlag is rangeDefinedByStartAddrMask"
+ ::= { brzaccVLMngIpRangeEntry 5 }
+
+ brzaccVLDeleteOneNwIpRange OBJECT-TYPE
+ SYNTAX INTEGER (0 | 1..10 | 255)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ 0 - cancel operation.
+ 1..10 - Deletes a single selected entry from the Management IP
+ Ranges Table."
+ ::= { brzaccVLNwMngParameters 11 }
+
+
+ brzaccVLDeleteAllNwIpRanges OBJECT-TYPE
+ SYNTAX INTEGER { deleteAll (1), cancelOperation (2), na (255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Deletes all entries from the Management IP Ranges Table."
+ ::= { brzaccVLNwMngParameters 12 }
+
+ brzaccVLApClientIpAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB unit only.
+ The IP Address of the WIFI WIMAX unit"
+ ::= { brzaccVLNwMngParameters 13 }
+
+-- IP Params:
+-- ===========
+brzaccVLIpParams OBJECT IDENTIFIER ::= {breezeAccessVLMib 4}
+
+ brzaccVLUnitIpAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ IP address of the unit."
+ ::= { brzaccVLIpParams 1 }
+
+ brzaccVLSubNetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Subnet mask of the unit."
+ ::= { brzaccVLIpParams 2 }
+
+ brzaccVLDefaultGWAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Default gateway IP address of the unit."
+ ::= { brzaccVLIpParams 3 }
+
+ brzaccVLUseDhcp OBJECT-TYPE
+ SYNTAX INTEGER{ disable (1),
+ dhcpOnly (2),
+ automatic (3) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ DHCP client mode of operation.
+ disabled : Use regular (manual) methods to configure IP
+ parameters.
+ dHCP Only: Use DHCP server to configure IP parameters.
+ automatic: Use DHCP server to configure IP parameters.
+ If a DHCP server is not available, use
+ manually configured values."
+ ::= { brzaccVLIpParams 4 }
+
+ brzaccVLAccessToDHCP OBJECT-TYPE
+ SYNTAX INTEGER{ fromWirelessOnly (1),
+ fromEthernetOnly (2),
+ fromBothWirelessAndEthernet (3) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The port to be used for communicating with a DHCP server."
+ ::= { brzaccVLIpParams 5 }
+
+ brzaccVLRunTimeIPaddr OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The run-time IP address. If DHCP is used the Run Time
+ IP Address is the address given to the unit by the
+ server. Otherwise it is the manually configured address."
+ ::= { brzaccVLIpParams 6 }
+
+ brzaccVLRunTimeSubNetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The run-time Subnet Mask. If DHCP is used the Run Time
+ Subnet Mask is the mask given to the unit by the server.
+ Otherwise it is the manually configured mask."
+ ::= { brzaccVLIpParams 7 }
+
+ brzaccVLRunTimeDefaultIPGateway OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The run-time Gateway IP address. If DHCP is used the
+ Run Time Gateway IP Address is the address given to the
+ unit by the server. Otherwise it is the manually
+ configured address."
+ ::= { brzaccVLIpParams 8 }
+
+
+-- Bridge Params
+-- ==============
+brzaccVLBridgeParameters OBJECT IDENTIFIER ::= {breezeAccessVLMib 5}
+
+
+brzaccVLVLANSupport OBJECT IDENTIFIER ::= {brzaccVLBridgeParameters 1}
+
+ brzaccVLVlanID OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ VLAN ID for data frame tagging.
+ Applicable to Access Link only.
+ Range: 1 to 4094. 0 - not applicable."
+ ::= { brzaccVLVLANSupport 1 }
+
+ brzaccVLEthernetLinkType OBJECT-TYPE
+ SYNTAX INTEGER { accessLink (1),
+ trunkLink (2),
+ hybridLink (3),
+ serviceProviderLink (4) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ VLAN support mode (Link Type).
+ The Access Link option is not available for AU/BU.
+ Service Provider Link is not available for BU/RB."
+ ::= { brzaccVLVLANSupport 2 }
+
+ brzaccVLManagementVlanID OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ VLAN ID for management frame tagging.
+ Range: 1 to 4094, 65535 for No VLAN tagging."
+ ::= { brzaccVLVLANSupport 3 }
+
+brzaccVLVLANForwarding OBJECT IDENTIFIER ::= {brzaccVLVLANSupport 4}
+
+ brzaccVLVlanForwardingSupport OBJECT-TYPE
+ SYNTAX INTEGER { disable (1) , enable (2), na(255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Enables or disables the VLAN forwarding feature.
+ (applicable in Trunk and Service Provider links only)."
+ ::= { brzaccVLVLANForwarding 1 }
+
+ brzaccVLVlanForwardingTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BrzaccVLVlanForwardingEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ A VLAN Forwarding Table of up to 20 VLAN IDs of devices
+ to which data frames are forwarded when VLAN Forwarding
+ is Enabled. (applicable in Trunk and Service Provider links only)."
+ ::= { brzaccVLVLANForwarding 2 }
+
+ brzaccVLVlanForwardingEntry OBJECT-TYPE
+ SYNTAX BrzaccVLVlanForwardingEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ A VLAN Forwarding Table entry. (applicable in Trunk and Service Provider
+ links only)."
+ INDEX { brzaccVLVlanForwardingTableIdx }
+ ::= { brzaccVLVlanForwardingTable 1 }
+
+ BrzaccVLVlanForwardingEntry ::= SEQUENCE {
+ brzaccVLVlanForwardingTableIdx INTEGER,
+ brzaccVLVlanIdForwarding INTEGER
+ }
+
+
+ brzaccVLVlanForwardingTableIdx OBJECT-TYPE
+ SYNTAX INTEGER (1..20)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ A read only table index for a VLAN entry in the VLAN
+ Forwarding Table."
+ ::= { brzaccVLVlanForwardingEntry 1 }
+
+ brzaccVLVlanIdForwarding OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The list of VLAN ID's in the VLAN ID Forwarding Table.
+ To Remove a VLAN ID - SET the corresponding entry to 0.
+ To Add a new VLAN ID SET an entry which is currently 0.
+ Range : 0 to 4094"
+ ::= { brzaccVLVlanForwardingEntry 2 }
+
+brzaccVLVlanRelaying OBJECT IDENTIFIER ::= {brzaccVLVLANSupport 5}
+
+ brzaccVLVlanRelayingSupport OBJECT-TYPE
+ SYNTAX INTEGER { disable (1) , enable (2), na(255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ Not applicable to BreezeNET-B products.
+ Enables or disables VLAN Relaying (applicable in
+ Trunk and Service Provider links only)."
+ ::= { brzaccVLVlanRelaying 1 }
+
+ brzaccVLVlanRelayingTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BrzaccVLVlanRelayingEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ Not applicable to BreezeNET-B products.
+ A VLAN Relaying Table of up to 20 VLAN IDs of devices
+ to which data frames are relayed when VLAN Relaying is
+ Enabled. (applicable in Trunk and Service Provider links only)."
+ ::= { brzaccVLVlanRelaying 2 }
+
+ brzaccVLVlanRelayingEntry OBJECT-TYPE
+ SYNTAX BrzaccVLVlanRelayingEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ Not applicable to BreezeNET-B products.
+ A VLAN Relaying Table entry. (applicable in Trunk and Service
+ Provider links only)."
+ INDEX { brzaccVLVlanRelayingTableIdx }
+ ::= { brzaccVLVlanRelayingTable 1 }
+
+ BrzaccVLVlanRelayingEntry ::= SEQUENCE {
+ brzaccVLVlanRelayingTableIdx INTEGER,
+ brzaccVLVlanIdRelaying INTEGER
+ }
+
+ brzaccVLVlanRelayingTableIdx OBJECT-TYPE
+ SYNTAX INTEGER (1..20)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ Not applicable to BreezeNET-B products.
+ A table index for a VLAN entry in the VLAN
+ Relaying Table."
+ ::= { brzaccVLVlanRelayingEntry 1 }
+
+
+ brzaccVLVlanIdRelaying OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ Not applicable to BreezeNET-B products.
+ The list of VLAN ID's in the VLAN ID Relaying Table.
+ To Remove a VLAN ID - SET the corresponding entry to 0.
+ To Add a new VLAN ID SET an entry which is currently 0.
+ Range: 0 to 4094 , 0 - remove entry."
+ ::= { brzaccVLVlanRelayingEntry 2 }
+
+
+brzaccVLVLANTrafficPriority OBJECT IDENTIFIER ::= {brzaccVLVLANSupport 6}
+
+ brzaccVLVlanDataPriority OBJECT-TYPE
+ SYNTAX INTEGER { na(255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Priority tagging for data frames. Applicable to Access
+ Link only.
+ Range: 0 to 7."
+ ::= { brzaccVLVLANTrafficPriority 1 }
+
+ brzaccVLVlanManagementPriority OBJECT-TYPE
+ SYNTAX INTEGER { na(255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Priority tagging for management frames. Applicable to
+ Access Link and Trunk Link only.
+ Range: 0 to 7."
+ ::= { brzaccVLVLANTrafficPriority 2 }
+
+
+ brzaccVLVlanPriorityThreshold OBJECT-TYPE
+ SYNTAX INTEGER { na(255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. Not applicable to units with SW
+ version 3.1 or higher.
+ Priority threshold for tagged frames received from
+ Ethernet port. Applicable to Hybrid Link and Trunk Link
+ only.
+ Valid values: 0-7."
+ ::= { brzaccVLVLANTrafficPriority 3 }
+
+ brzaccVLVLANQinQ OBJECT IDENTIFIER ::= {brzaccVLVLANSupport 7}
+
+ brzaccVLQinQEthertype OBJECT-TYPE
+ SYNTAX INTEGER (33025 .. 36864|37120|37376)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU and SU. Not applicable to BreezeNET-B units.
+ The Ethernet type of the Service Provider Tag.
+ The range is 0x8101(33025) - 0x9000(36864), 0x9100(37120), 0x9200(37376)."
+ ::= { brzaccVLVLANQinQ 1 }
+
+ brzaccVLQinQProviderVlanID OBJECT-TYPE
+ SYNTAX INTEGER (1..4094)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU only.
+ VLAN ID of the Service Provider Tag."
+ ::= { brzaccVLVLANQinQ 2 }
+
+ brzaccVLBridgeAgingTime OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Bridge aging time for devices on both the Ethernet and
+ wireless link sides.
+ Range: 20 to 2000 seconds."
+ ::= { brzaccVLBridgeParameters 2 }
+
+ brzaccVLBroadcastRelaying OBJECT-TYPE
+ SYNTAX INTEGER { disable (1),
+ broadcastMulticastEnable (2),
+ broadcastEnable (3),
+ multicastEnable (4),
+ na (255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ Not applicable to BreezeNET-B products.
+ Enables/disables the relaying of broadcast messages to
+ the wireless link."
+ ::= { brzaccVLBridgeParameters 4 }
+
+ brzaccVLUnicastRelaying OBJECT-TYPE
+ SYNTAX INTEGER { disable(1), enable(2), na (255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ Not applicable to BreezeNET-B products.
+ Enables/disables the relaying of unicast messages to
+ the wireless link."
+ ::= { brzaccVLBridgeParameters 5 }
+
+ brzaccVLEthBroadcastFiltering OBJECT-TYPE
+ SYNTAX INTEGER { disable (1),
+ onEthernetOnly (2),
+ onWirelessOnly (3),
+ onBothWirelessAndEthernet (4),
+ na (255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Enables/disables the filtering of Ethernet (layer2)
+ broadcasts.
+ disable : No filtering.
+ onEthernetOnly : Filters broadcasts received on the Ethernet port only.
+ onWirelessOnly : Filters broadcasts received on the Wlan port only.
+ onBothWirelessAndEth: Filters broadcasts received on both ports."
+ ::= { brzaccVLBridgeParameters 6 }
+
+brzaccVLEthBroadcastingParameters OBJECT IDENTIFIER ::= {brzaccVLBridgeParameters 7}
+
+ brzaccVLDHCPBroadcastOverrideFilter OBJECT-TYPE
+ SYNTAX INTEGER { disable (1), enable (2), na (255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Enables or disables the broadcasting of DHCP messages,
+ overriding the general *brzaccVLEthBroadcastFiltering Ethernet
+ broadcast filtering option."
+ ::= { brzaccVLEthBroadcastingParameters 1 }
+
+ brzaccVLPPPoEBroadcastOverrideFilter OBJECT-TYPE
+ SYNTAX INTEGER { disable (1), enable (2), na (255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Enables or disables the broadcasting of PPPoE messages,
+ overriding the general *brzaccVLEthBroadcastFiltering Ethernet
+ broadcast filtering option."
+ ::= { brzaccVLEthBroadcastingParameters 2 }
+
+ brzaccVLARPBroadcastOverrideFilter OBJECT-TYPE
+ SYNTAX INTEGER { disable (1), enable (2), na (255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Enables or disables the broadcasting of ARP messages,
+ overriding the general *brzaccVLEthBroadcastFiltering Ethernet
+ broadcast filtering option."
+ ::= { brzaccVLEthBroadcastingParameters 3 }
+
+ brzaccVLEthBroadcastMulticastLimiterOption OBJECT-TYPE
+ SYNTAX INTEGER { disable (1),
+ limitOnlyBroadcasts(2),
+ limitMulticastsExceptBroadcasts(3),
+ limitAllMulticasts(4) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Enable/disable the limiter for multicast and broadcast packets."
+ ::= { brzaccVLEthBroadcastingParameters 4 }
+
+ brzaccVLEthBroadcastMulticastLimiterThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The limit on the number of multicast and broadcast packets when the
+ Ethernet Broadcast/Multicast Limiter Option is enabled.
+ Range: 0 to 204800"
+ ::= { brzaccVLEthBroadcastingParameters 5 }
+
+ brzaccVLEthBroadcastMulticastLimiterSendTrapInterval OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The minimum time between two successive traps that are sent indicating the
+ number of packets that were dropped by the Ethernet Broadcast/Multicast
+ Limiter since the last trap was sent.
+ Range: 1 to 60 minutes"
+ ::= { brzaccVLEthBroadcastingParameters 6 }
+
+brzaccVLToSPriorityParameters OBJECT IDENTIFIER ::= {brzaccVLBridgeParameters 8}
+
+ brzaccVLToSPrecedenceThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. Not applicable to units with SW version 3.1 or higher.
+ Priority threshold (based on the ToS) for frames received
+ from the Ethernet port.
+ Range: 0 to 7."
+ ::= { brzaccVLToSPriorityParameters 1 }
+
+ brzaccVLRoamingOption OBJECT-TYPE
+ SYNTAX INTEGER { disable (1), enable (2), na(255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Disable/enable the roaming feature. When enabled, the SU/RB will start
+ scanning for an AU/BU after about one second of not receiving beacons or data
+ from current AU/BU. Once it found a new AU/BU, it will also send through
+ the wireless network a roaming SNAP on behalf of its clients informing
+ other devices in the network of their new location. When disabled, it
+ will wait for about seven seconds before starting scanning, and it will not
+ send a roaming SNAP."
+ ::= { brzaccVLBridgeParameters 9 }
+
+brzaccVLMacAddressDenyList OBJECT IDENTIFIER ::= {brzaccVLBridgeParameters 10}
+
+ brzaccVLMacAddressDenyListTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BrzaccVLMacAddressDenyListEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ Not applicable to BreezeNET-B units.
+ A list of up to 100 MAC Addresses of SUs.
+ If brzaccVLMacAddressDenyListAction is set to denyList,
+ these are SUs that are not allowed to transfer data
+ to the AU.
+ If brzaccVLMacAddressDenyListAction is set to allowList,
+ only these SUs are allowed to transfer data to the AU."
+ ::= { brzaccVLMacAddressDenyList 1 }
+
+ brzaccVLMacAddressDenyListEntry OBJECT-TYPE
+ SYNTAX BrzaccVLMacAddressDenyListEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ Not applicable to BreezeNET-B units.
+ An entry in the Mac Address Deny List Table."
+ INDEX { brzaccVLMacAddressDenyListTableIdx }
+ ::= { brzaccVLMacAddressDenyListTable 1 }
+
+ BrzaccVLMacAddressDenyListEntry ::= SEQUENCE {
+ brzaccVLMacAddressDenyListTableIdx INTEGER,
+ brzaccVLMacAddressDenyListId MacAddress
+ }
+
+ brzaccVLMacAddressDenyListTableIdx OBJECT-TYPE
+ SYNTAX INTEGER (1..100)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ Not applicable to BreezeNET-B units.
+ A read only table index for a MAC Address entry
+ in the Mac Address Deny List Table. Range: 1 to 100."
+ ::= { brzaccVLMacAddressDenyListEntry 1 }
+
+ brzaccVLMacAddressDenyListId OBJECT-TYPE
+ SYNTAX MacAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ Not applicable to BreezeNET-B units.
+ The list of MAC Addresses in the Mac Address Deny
+ List Table.
+ To Remove a MAC Address - SET the corresponding entry
+ to 0.
+ To Add a new MAC Address - SET an entry which is
+ currently 0."
+ ::= { brzaccVLMacAddressDenyListEntry 2 }
+
+ brzaccVLMacAddressDenyListAdd OBJECT-TYPE
+ SYNTAX MacAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ Not applicable to BreezeNET-B units.
+ Add a MAC address to the MAC Address Deny List Table"
+ ::= { brzaccVLMacAddressDenyList 2 }
+
+ brzaccVLMacAddressDenyListRemove OBJECT-TYPE
+ SYNTAX MacAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ Not applicable to BreezeNET-B units.
+ Delete a MAC address from the MAC Address Deny List Table"
+ ::= { brzaccVLMacAddressDenyList 3 }
+
+ brzaccVLNumberOfMacAddressesInDenyList OBJECT-TYPE
+ SYNTAX INTEGER { na(255) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ Not applicable to BreezeNET-B units.
+ Number of MAC addresses in the MAC Address Deny List Table."
+ ::= { brzaccVLMacAddressDenyList 4 }
+
+brzaccVLMacAddressDenyListAction OBJECT-TYPE
+ SYNTAX INTEGER { denyList(1), allowedList(2), na(255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ Define the action to be used by the Mac Address Deny List.
+ allowedList(2) means that the list becomes Allow list."
+ ::= { brzaccVLMacAddressDenyList 5 }
+
+
+brzAccVLPortsControl OBJECT IDENTIFIER ::= {brzaccVLBridgeParameters 11}
+
+ brzaccVLEthernetPortControl OBJECT-TYPE
+ SYNTAX INTEGER { disable(1), enable(2), na(255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Enable/disable the Ethernet port. When disabled, only
+ data frames are blocked. Management frames are accepted."
+ ::= { brzAccVLPortsControl 1 }
+
+
+-- Air Interface Params
+-- =====================
+brzaccVLAirInterface OBJECT IDENTIFIER ::= {breezeAccessVLMib 6}
+
+brzaccVLESSIDParameters OBJECT IDENTIFIER ::= {brzaccVLAirInterface 1}
+
+ brzaccVLESSID OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..31))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The Extended Service Set ID (ESSID) used to prevent
+ the merging of collocated systems.
+ The ESSID is accessible only with the write community
+ string (administrator password).
+ Up to 31 printable case sensitive ASCII characters."
+ ::= { brzaccVLESSIDParameters 1 }
+
+
+ brzaccVLOperatorESSIDOption OBJECT-TYPE
+ SYNTAX INTEGER {disable (1) , enable (2), na (255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Enabling/disabling the use of the Operator ESSID."
+ ::= { brzaccVLESSIDParameters 2 }
+
+
+ brzaccVLOperatorESSID OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..31))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ A secondary ESSID to support easy installation of SUs as well as
+ the use of the Best AU/BU feature.
+ Accessible only with SNMP Write Community
+ Up to 31 printable case sensitive ASCII characters."
+ ::= { brzaccVLESSIDParameters 3}
+
+ brzaccVLRunTimeESSID OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(31))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ The ESSID of the associated AU/BU.
+ Accessible only with SNMP Write Community.
+ Up to 31 printable ASCII characters, case sensitive."
+ ::= { brzaccVLESSIDParameters 4 }
+
+
+ brzaccVLMaximumCellRadius OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ For AU/BU: read-write. In units with SW version 2.0 and up -
+ applicable only when the Cell Distance Mode is set to Manual.
+ The highest distance from the AU/BU of any SU/RB served by it.
+ Affects the maximum time the units wait for a response message
+ and the slot size by taking into account the round trip propagation delay.
+ For SU/RB: read-only. The distance is learned from the AU/BU.
+ Range: For units below version 2.0 the range is 0 - 50000 Meters.
+ Otherwise - the range is 0 to 54 Kilometers.
+ 0 means no compensation (minimum slot size, maximal delay timeout)."
+ ::= { brzaccVLAirInterface 2 }
+
+ brzaccVLAIFS OBJECT-TYPE
+ SYNTAX INTEGER { oneSlot (1), twoSlots (2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU and SU. Not applicable to BreezeNET-B products.
+ Not applicable if Wireless Link Prioritization is enabled.
+ Arbitration Inter-Frame Spacing (AIFS) value, in slots.
+ This is the number of time slots that define the DIFS. (DIFS=SIFS+AIFS).
+ A value of 1 should be used only in point-to-point applications to
+ allow one unit to have advantage over the other unit."
+ ::= { brzaccVLAirInterface 3 }
+
+
+ brzaccVLWirelessTrapThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ A wireless link quality threshold, expressed in % of retransmissions,
+ for sending the brzaccVLAUWirelessQualityTRAP.
+ This trap indicate whether the quality has gone below or
+ above the specified threshold.
+ The Threshold Range: 1 to 100 (% retransmissions)."
+ ::= { brzaccVLAirInterface 4 }
+
+
+
+ brzaccVLTransmitPowerTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BrzaccVLTransmitPowerEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ A table of transmit power parameters. "
+ ::= { brzaccVLAirInterface 5}
+
+ brzaccVLTransmitPowerEntry OBJECT-TYPE
+ SYNTAX BrzaccVLTransmitPowerEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ An entry in the Transmit Power Table."
+ INDEX { brzaccVLTransmitPowerIdx }
+ ::= { brzaccVLTransmitPowerTable 1 }
+
+ BrzaccVLTransmitPowerEntry ::= SEQUENCE { brzaccVLTransmitPowerIdx INTEGER,
+ brzaccVLApplicableModulationLevel INTEGER,
+ brzaccVLMaximumTxPowerRange DisplayString,
+ brzaccVLTxPower DisplayString,
+ brzaccVLCurrentTxPower DisplayString
+ }
+
+ brzaccVLTransmitPowerIdx OBJECT-TYPE
+ SYNTAX INTEGER (1..4)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ An index of an entry in the Transmit Power Table."
+ ::= { brzaccVLTransmitPowerEntry 1 }
+
+
+ brzaccVLApplicableModulationLevel OBJECT-TYPE
+ SYNTAX INTEGER {level1to5 (1), level6 (2), level7 (3),level8 (4)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The applicable modulation level for an entry in the Transmit Power Table.
+ Level 8 is not applicable to units with HW revision A."
+ ::= { brzaccVLTransmitPowerEntry 2 }
+
+ brzaccVLMaximumTxPowerRange OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The allowed range for the brzaccVLTxPower parameter at the
+ applicable modulation level . Range: -10 to the maximum allowed
+ power level at the applicable modulation level , in dBm."
+ ::= { brzaccVLTransmitPowerEntry 3 }
+
+
+ brzaccVLTxPower OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Read-only for units with SW version 4.0 and higher.
+ In AU/BU: The transmit power in dBm defined for the applicable rate.
+ In SU/RB: If ATPC is disabled, this is the transmit power in dBm
+ defined for the applicable rate.
+ If ATPC is enabled, it serves as the initial transmit power in dBm
+ for the ATPC algorithm.
+ In SU/RB: The range is -10 dBm to the power value defined by
+ brzaccVLMaximumTxPower for the applicable modulation level.
+ In AU/BU: The range is -10 dBm to the power value defined by
+ brzaccVLMaximumTxPowerRange for the applicable modulation level."
+ ::= { brzaccVLTransmitPowerEntry 4 }
+
+
+
+ brzaccVLCurrentTxPower OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB.
+ The actual transmit power in dBm for the applicable rate.
+ Range: -17 to the maximum value defined by brzaccVLMaximumTxPowerRange
+ for the applicable modulation level."
+ ::= { brzaccVLTransmitPowerEntry 5 }
+
+ brzaccVLMaximumTransmitPowerTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BrzaccVLMaximumTransmitPowerEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ A table of maximum transmit power parameters. "
+ ::= { brzaccVLAirInterface 6}
+
+ brzaccVLMaximumTransmitPowerEntry OBJECT-TYPE
+ SYNTAX BrzaccVLMaximumTransmitPowerEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ An entry in the Maximum Transmit Power Table."
+ INDEX { brzaccVLMaximumTransmitPowerIdx }
+ ::= { brzaccVLMaximumTransmitPowerTable 1 }
+
+ BrzaccVLMaximumTransmitPowerEntry ::= SEQUENCE { brzaccVLMaximumTransmitPowerIdx INTEGER,
+ brzaccVLMaxTxApplicableModulationLevel INTEGER,
+ brzaccVLDefinedMaximumTxPowerRange DisplayString,
+ brzaccVLMaxTxPower DisplayString
+ }
+
+ brzaccVLMaximumTransmitPowerIdx OBJECT-TYPE
+ SYNTAX INTEGER (1..4)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ An index of an entry in the Maximum Transmit Power Table."
+ ::= { brzaccVLMaximumTransmitPowerEntry 1 }
+
+
+ brzaccVLMaxTxApplicableModulationLevel OBJECT-TYPE
+ SYNTAX INTEGER {level1to5 (1), level6 (2), level7 (3),level8 (4)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ The applicable modulation level for an entry in the Maximum
+ Transmit Power Table.
+ Level 8 is not applicable to units with HW revision A."
+ ::= { brzaccVLMaximumTransmitPowerEntry 2 }
+
+ brzaccVLDefinedMaximumTxPowerRange OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ The allowed range for the brzaccVLMaxTxPower parameter at the
+ applicable modulation level .
+ Range: -10 to the maximum allowed power level at the applicable
+ modulation level , in dBm."
+ ::= { brzaccVLMaximumTransmitPowerEntry 3 }
+
+
+ brzaccVLMaxTxPower OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Read-only for units with SW version 4.0 and higher.
+ The maximum value that can be configured for the brzaccVLTxPower
+ parameter. This is also the maximum power level that can be reached
+ by the ATPC algorithm.
+ The range is -10 dBm to the maximum value defined by
+ brzaccVLDefinedMaximumTxPowerRange for the applicable modulation level."
+ ::= { brzaccVLMaximumTransmitPowerEntry 4 }
+
+ brzaccVLMaxNumOfAssociations OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ Not applicable to BreezeNET-B products.
+ Sets the upper limit for the number of SUs
+ that can be associated with the AU.
+ Range: For regular AUs (AU-BS, AU-SA)
+ the range is from 0 to 512 if encryption is disabled
+ the range id form 0 to 124 if encryption is enabled
+ For AUS-BS and AUS-SA with SW version 4.0 and higher
+ the range is between 0 to 8 or 25 (via licensing).
+ For AUS-BS and AUS-SA with SW version below 4.0 the range
+ is between 0 to 5.
+ BreezeNET-B products return 65535."
+ ::= { brzaccVLAirInterface 10 }
+
+
+brzaccVLBestAu OBJECT IDENTIFIER ::= {brzaccVLAirInterface 11}
+
+ brzaccVLBestAuSupport OBJECT-TYPE
+ SYNTAX INTEGER { disable (1), enable (2), na (255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Disable/enable the Best AU/BU selection mechanism."
+ ::= { brzaccVLBestAu 1 }
+
+ brzaccVLBestAuNoOfScanningAttempts OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ The number of scanning attempts to collect information
+ for the Best AU/BU decision.
+ Range: 1 to 255."
+ ::= { brzaccVLBestAu 2 }
+
+ brzaccVLPreferredAuMacAddress OBJECT-TYPE
+ SYNTAX MacAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ The MAC address of the preferred AU/BU (overriding the
+ Best AU/BU selection process).
+ 000000000000 means no preferred AU/BU."
+ ::= { brzaccVLBestAu 3 }
+
+ brzaccVLNeighborAuTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BrzaccVLNeighborAuEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ A table of data on neighboring AUs/BUs."
+ ::= { brzaccVLBestAu 4}
+
+ brzaccVLNeighborAuEntry OBJECT-TYPE
+ SYNTAX BrzaccVLNeighborAuEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ An entry in the Neighbor AU/BU Table."
+ INDEX { brzaccVLNeighborAuIdx }
+ ::= { brzaccVLNeighborAuTable 1 }
+
+ BrzaccVLNeighborAuEntry ::= SEQUENCE { brzaccVLNeighborAuIdx INTEGER,
+ brzaccVLNeighborAuMacAdd MacAddress,
+ brzaccVLNeighborAuESSID DisplayString,
+ brzaccVLNeighborAuSNR INTEGER,
+ brzaccVLNeighborAuAssocLoadStatus INTEGER,
+ brzaccVLNeighborAuMark INTEGER,
+ brzaccVLNeighborAuHwRevision INTEGER,
+ brzaccVLNeighborAuCountryCode INTEGER,
+ brzaccVLNeighborAuSwVer DisplayString,
+ brzaccVLNeighborAuAtpcOption INTEGER,
+ brzaccVLNeighborAuAdapModOption INTEGER,
+ brzaccVLNeighborAuBurstModeOption INTEGER,
+ brzaccVLNeighborAuDfsOption INTEGER,
+ brzaccVLNeighborAuConcatenationOption INTEGER,
+ brzaccVLNeighborAuLearnCountryCodeBySU INTEGER,
+ brzaccVLNeighborAuSecurityMode INTEGER,
+ brzaccVLNeighborAuAuthOption INTEGER,
+ brzaccVLNeighborAuDataEncyptOption INTEGER,
+ brzaccVLNeighborAuPerSuDistanceLearning INTEGER
+ }
+
+ brzaccVLNeighborAuIdx OBJECT-TYPE
+ SYNTAX INTEGER (1..20)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ An index of an entry in the Neighbor AU/BU Table."
+ ::= { brzaccVLNeighborAuEntry 1 }
+
+ brzaccVLNeighborAuMacAdd OBJECT-TYPE
+ SYNTAX MacAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ A MAC address of an AU/BU in the Neighbor AU/BU Table."
+ ::= { brzaccVLNeighborAuEntry 2 }
+
+ brzaccVLNeighborAuESSID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ The ESSID of an AU/BU in the Neighbor AU/BU Table.
+ Accessible only with SNMP Write Community."
+ ::= { brzaccVLNeighborAuEntry 3 }
+
+ brzaccVLNeighborAuSNR OBJECT-TYPE
+ SYNTAX INTEGER { na (255) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ The received signal quality (SNR) in dB of an AU/BU
+ in the Neighbor AU/BU Table."
+ ::= { brzaccVLNeighborAuEntry 4 }
+
+ brzaccVLNeighborAuAssocLoadStatus OBJECT-TYPE
+ SYNTAX INTEGER { full (1),notFull (2), na (255) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Neighbor AU/BU association load status in the Neighbor
+ AU/BU Table."
+ ::= { brzaccVLNeighborAuEntry 5 }
+
+ brzaccVLNeighborAuMark OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Neighbor AU/BU mark in the Neighbor AU/BU Table."
+ ::= { brzaccVLNeighborAuEntry 6 }
+
+ brzaccVLNeighborAuHwRevision OBJECT-TYPE
+ SYNTAX INTEGER {hwRevisionA (1), hwRevisionB (2), hwRevisionC (3),
+ hwRevisionD (4), hwRevisionE (5),na (255)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Neighbor AU/BU HW revision in the Neighbor AU/BU Table."
+ ::= { brzaccVLNeighborAuEntry 7 }
+
+ brzaccVLNeighborAuCountryCode OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Neighbor AU/BU supported country code in the Neighbor
+ AU/BU Table."
+ ::= { brzaccVLNeighborAuEntry 8 }
+
+ brzaccVLNeighborAuSwVer OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Neighbor AU/BU SW version in the Neighbor
+ AU/BU Table."
+ ::= { brzaccVLNeighborAuEntry 9 }
+
+ brzaccVLNeighborAuAtpcOption OBJECT-TYPE
+ SYNTAX INTEGER { disable (1), enable (2), na (255)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Neighbor AU/BU ATPC option configuration in the Neighbor
+ AU/BU Table."
+ ::= { brzaccVLNeighborAuEntry 10 }
+
+ brzaccVLNeighborAuAdapModOption OBJECT-TYPE
+ SYNTAX INTEGER { disable (1), enable (2), na (255)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Neighbor AU/BU adaptive modulation option configuration
+ in the Neighbor AU/BU Table."
+ ::= { brzaccVLNeighborAuEntry 11 }
+
+ brzaccVLNeighborAuBurstModeOption OBJECT-TYPE
+ SYNTAX INTEGER { disable (1), enable (2), na (255)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Neighbor AU/BU burst mode option configuration
+ in the Neighbor AU/BU Table."
+ ::= { brzaccVLNeighborAuEntry 12 }
+
+ brzaccVLNeighborAuDfsOption OBJECT-TYPE
+ SYNTAX INTEGER { disable (1), enable (2), na(255)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Neighbor AU/BU DFS option configuration
+ in the Neighbor AU/BU Table."
+ ::= { brzaccVLNeighborAuEntry 14 }
+
+ brzaccVLNeighborAuConcatenationOption OBJECT-TYPE
+ SYNTAX INTEGER { disable (1), enable (2), na (255)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Neighbor AU/BU concatenation option configuration
+ in the Neighbor AU/BU Table."
+ ::= { brzaccVLNeighborAuEntry 15 }
+
+ brzaccVLNeighborAuLearnCountryCodeBySU OBJECT-TYPE
+ SYNTAX INTEGER { disable (1), enable (2), na (255)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU only.
+ Starting with 4.0 is not applicable for BA4900 and BreezeNET B products.
+ Neighbor AU Learn Country Code by SU configuration
+ in the Neighbor AU Table."
+ ::= { brzaccVLNeighborAuEntry 17 }
+
+ brzaccVLNeighborAuSecurityMode OBJECT-TYPE
+ SYNTAX INTEGER {wep(1), aesOCB(2), fips197(3), na (255)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Neighbor AU/BU security mode configuration
+ in the Neighbor AU/BU Table."
+ ::= { brzaccVLNeighborAuEntry 18 }
+
+ brzaccVLNeighborAuAuthOption OBJECT-TYPE
+ SYNTAX INTEGER {openSystem (1), sharedKey (2), na (255)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Neighbor AU/BU authentication option configuration
+ in the Neighbor AU/BU Table."
+ ::= { brzaccVLNeighborAuEntry 19 }
+
+ brzaccVLNeighborAuDataEncyptOption OBJECT-TYPE
+ SYNTAX INTEGER {disable (1), enable (2), na (255)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Neighbor AU/BU data encryption option configuration
+ in the Neighbor AU/BU Table."
+ ::= { brzaccVLNeighborAuEntry 20 }
+
+ brzaccVLNeighborAuPerSuDistanceLearning OBJECT-TYPE
+ SYNTAX INTEGER {disable (1), enable (2), na (255)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU only.
+ Neighbor AU per SU distance learning option configuration
+ in the Neighbor AU Table."
+ ::= { brzaccVLNeighborAuEntry 21 }
+
+brzaccVLFrequencyDefinition OBJECT IDENTIFIER ::= {brzaccVLAirInterface 12}
+
+
+ brzaccVLSubBandLowerFrequency OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS obsolete
+ DESCRIPTION
+ "Applicable to SU only.
+ Not applicable to units with SW version 2.0 or higher.
+ The lowest frequency in the subset to be used for scanning.
+ For 5.8GHz products the range is 5740 to 5830 MHz using 10MHz resolution.
+ For 4.9GHz products the range is 4920 to 5080 MHz using 10MHz resolution.
+ For HW Revision C and above this leaf is not relevant - shall return 0."
+ ::= { brzaccVLFrequencyDefinition 1 }
+
+ brzaccVLSubBandUpperFrequency OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS obsolete
+ DESCRIPTION
+ "Applicable to SU only.
+ Not applicable to units with SW version 2.0 or higher.
+ The highest frequency in the subset to be used for scanning.
+ For 5.8GHz products the range is 5740 to 5830 MHz using 10MHz resolution.
+ For 4.9GHz products the range is 4920 to 5080 MHz using 10MHz resolution.
+ For HW Revision C and above this leaf is not relevant - shall return 0."
+ ::= { brzaccVLFrequencyDefinition 2 }
+
+ brzaccVLScanningStep OBJECT-TYPE
+ SYNTAX INTEGER { mhz-5(1), mhz-10(2) , mhz-20(3), na(255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units - For flexible Sub-Bands only.
+ For units with version 2.0 and above this is a read-only parameter.
+ The scanning step to be used for generating the frequency subset."
+ ::= { brzaccVLFrequencyDefinition 3 }
+
+
+ brzaccVLFrequencySubsetTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BrzaccVLFrequencySubsetEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB and to AU/BU.
+ Not applicable to SU/RB with SW version 4.0 and higher.
+ The Frequency Subset Table that includes all frequencies from
+ the selected Sub-band."
+ ::= { brzaccVLFrequencyDefinition 4 }
+
+ brzaccVLFrequencySubsetEntry OBJECT-TYPE
+ SYNTAX BrzaccVLFrequencySubsetEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB and to AU/BU.
+ Not applicable to SU/RB with SW version 4.0 and higher.
+ An entry in the Frequency Subset Table. "
+ INDEX { brzaccVLFrequencySubsetTableIdx }
+ ::= { brzaccVLFrequencySubsetTable 1 }
+
+ BrzaccVLFrequencySubsetEntry ::= SEQUENCE {
+ brzaccVLFrequencySubsetTableIdx INTEGER,
+ brzaccVLFrequencySubsetFrequency INTEGER,
+ brzaccVLFrequencySubsetActive INTEGER,
+ brzaccVLFrequencySubsetFrequencyNew DisplayString
+ }
+
+ brzaccVLFrequencySubsetTableIdx OBJECT-TYPE
+ SYNTAX INTEGER (1..40)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB and to AU/BU.
+ Not applicable to SU/RB with SW version 4.0 and higher.
+ An index of an entry in the Frequency subset Table."
+ ::= { brzaccVLFrequencySubsetEntry 1 }
+
+
+ brzaccVLFrequencySubsetFrequency OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB and to AU/BU.
+ Not applicable to SU/RB with SW version 4.0 and higher.
+ Applicable to all units with HW revision B and lower
+ (for units with HW revision C and higher replaced by
+ brzaccVLFrequencySubsetFrequencyNew to support a
+ resolution of 0.5 MHz).
+ The frequency in MHz of an entry in the Frequency Subset table."
+ ::= { brzaccVLFrequencySubsetEntry 2 }
+
+ brzaccVLFrequencySubsetActive OBJECT-TYPE
+ SYNTAX INTEGER {active (1) , notActive (2)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB and to AU/BU.
+ Not applicable to SU/RB with SW version 4.0 and higher.
+ The status of an entry in the Frequency subset Table.
+ The frequency of an active entry will be included in the
+ final list of frequencies to be used for scanning."
+ ::= { brzaccVLFrequencySubsetEntry 3 }
+
+ brzaccVLFrequencySubsetFrequencyNew OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Not applicable to SU/RB with SW version 4.0 and higher.
+ The frequency in MHz of an entry in the Frequency Subset table.
+ (Replaces brzaccVLFrequencySubsetFrequency to support a resolution
+ of 0.5 MHz for units with HW revision C and higher)."
+ ::= { brzaccVLFrequencySubsetEntry 4 }
+
+ brzaccVLSetSelectedFreqSubset OBJECT-TYPE
+ SYNTAX INTEGER {setSelectedFreqsSubset(1) ,cancel (2)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB and to AU/BU.
+ Not applicable to SU/RB with SW version 4.0 and higher.
+ Apply the selected subset.
+ After the next reset the new subset will be used."
+ ::= { brzaccVLFrequencyDefinition 5 }
+
+
+
+
+ brzaccVLCurrentFrequencySubsetTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BrzaccVLCurrentFrequencySubsetEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB and to AU/BU.
+ Not applicable to SU/RB with SW version 4.0 and higher.
+ The Current Frequency Subset table. In SU/RB it includes all
+ frequencies that are currently used for scanning.
+ In AU/BU it includes all frequencies that can be used by the
+ DFS mechanism (if applicable)"
+ ::= { brzaccVLFrequencyDefinition 6 }
+
+ brzaccVLCurrentFrequencySubsetEntry OBJECT-TYPE
+ SYNTAX BrzaccVLCurrentFrequencySubsetEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB and to AU/BU.
+ An entry in the Current Frequency Subset Table. "
+ INDEX { brzaccVLCurrentFrequencySubsetTableIdx }
+ ::= { brzaccVLCurrentFrequencySubsetTable 1 }
+
+ BrzaccVLCurrentFrequencySubsetEntry ::= SEQUENCE {
+ brzaccVLCurrentFrequencySubsetTableIdx INTEGER,
+ brzaccVLCurrentFrequencySubsetFrequency INTEGER,
+ brzaccVLCurrentFrequencySubsetFrequencyNew DisplayString
+ }
+
+ brzaccVLCurrentFrequencySubsetTableIdx OBJECT-TYPE
+ SYNTAX INTEGER (1..40)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB and to AU/BU.
+ An index of an entry in the Current Frequency subset Table.
+ Not applicable to SU/RB with SW version 4.0 and higher."
+ ::= { brzaccVLCurrentFrequencySubsetEntry 1 }
+
+
+ brzaccVLCurrentFrequencySubsetFrequency OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Not applicable to SU/RB with SW version 4.0 and higher.
+ Applicable to all units with HW revision B and lower
+ (for units with HW revision C and higher replaced by
+ brzaccVLCurrentFrequencySubsetFrequencyNew to support
+ a resolution of 0.5 MHz).
+ The frequency in MHz of an entry in the Current Frequency Subset table."
+ ::= { brzaccVLCurrentFrequencySubsetEntry 2 }
+
+ brzaccVLCurrentFrequencySubsetFrequencyNew OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. Not applicable to SU/RB with SW version 4.0 and higher.
+ The frequency in MHz of an entry in the Current Frequency Subset table.
+ (Replaces brzaccVLCurrentFrequencySubsetFrequency to support a
+ resolution of 0.5 MHz for units with HW revision C and higher)."
+ ::= { brzaccVLCurrentFrequencySubsetEntry 3 }
+
+ brzaccVLCurrentAUOperatingFrequency OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU with HW revision B and lower
+ (for units with HW revision C and higher replaced by
+ brzaccVLCurrentUOperatingFrequencyNew to support a resolution
+ of 0.5 MHz).
+ The operating frequency in MHz.
+ For 5.8GHz products with SW version below 2.0 the range is
+ 5740 to 5830 MHz using 10MHz resolution.
+ For units with SW version 2.0 and up the range is as defined
+ in the selected Sub Band."
+ ::= { brzaccVLFrequencyDefinition 7 }
+
+ brzaccVLCurrentAUOperatingFrequencyNew OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU. The operating frequency in MHz.
+ (Replaces brzaccVLCurrentAUOperatingFrequency to support
+ a resolution of 0.5 MHz for units with HW revision C and higher).
+ For 5.8GHz products with SW version below 2.0 the range is
+ 5740 to 5830 MHz using 10MHz resolution.
+ For units with SW version 2.0 and up the range is as defined
+ in the selected Sub Band."
+ ::= { brzaccVLFrequencyDefinition 13 }
+
+ brzaccVLAUDefinedFrequency OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU with HW revision B and lower
+ (for units with HW revision C and higher replaced by
+ brzaccVLAUDefinedFrequencyNew to support a resolution of 0.5 MHz).
+ For 5.8GHz products with SW version below 2.0 this is the frequency
+ in MHz of the AU/BU after the next reset.
+ For units with SW version 2.0 and up this is the frequency in MHz
+ to use when the DFS Option is disabled.
+ For 5.8GHz products with SW version below 2.0 the range is
+ 5740 to 5830 MHz using 10MHz resolution.
+ For units with SW version 2.0 and up the range is as defined
+ in the selected Sub Band."
+ ::= { brzaccVLFrequencyDefinition 8 }
+
+ brzaccVLAUDefinedFrequencyNew OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU.
+ For 5.8GHz products with SW version below 2.0 this is the
+ frequency in MHz of the AU/BU after the next reset.
+ For units with SW version 2.0 and up this is the
+ frequency in MHz to use when the DFS Option is disabled.
+ (Replaces brzaccVLAUDefinedFrequency to support a resolution
+ of 0.5 MHz for units with HW revision C and higher).
+ For 5.8GHz products with SW version below 2.0 the range
+ is 5740 to 5830 MHz using 10MHz resolution.
+ For units with SW version 2.0 and up the range is as
+ defined in the selected Sub Band."
+ ::= { brzaccVLFrequencyDefinition 14 }
+
+ brzaccVLCurrentSUOperatingFrequency OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ The frequency used currently by the unit.
+ For 5.8GHz products with SW version below 2.0 the range is
+ 5740 to 5830 MHz using 10MHz resolution.
+ For units with SW version 2.0 and up the range is as defined
+ in the selected Sub Band."
+ ::= { brzaccVLFrequencyDefinition 9 }
+
+brzaccVLSubBandSelect OBJECT IDENTIFIER ::= {brzaccVLFrequencyDefinition 10}
+
+
+ brzaccVLSelectSubBandIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units with SW version below 4.0
+ For units with SW version 4.0 and up it is applicable
+ only for AU/BU. For SU/RB it defines only the sub-band
+ for the Spectrum Analyzer.
+ The ID of the sub-band used by the unit."
+ ::= { brzaccVLSubBandSelect 1 }
+
+
+
+brzaccVLDFSParameters OBJECT IDENTIFIER ::= {brzaccVLFrequencyDefinition 11}
+
+ brzaccVLDFSOption OBJECT-TYPE
+ SYNTAX INTEGER { disable (1) , enable (2), na (255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Enabling/disabling the DFS Algorithm.
+ Not applicable if DFS Option is not supported by the current Sub Band."
+ ::= { brzaccVLDFSParameters 1 }
+
+ brzaccVLDFSChannelCheckTime OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Defines the time the unit checks the channel for presence of
+ radar signals and does not transmit after power up or association
+ or after moving to a new channel due to detecting radar in the used
+ channel. Range: 1 to 3600 (seconds)."
+ ::= { brzaccVLDFSParameters 3 }
+
+
+ brzaccVLDFSChannelAvoidancePeriod OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Defines the time after detecting radar signals in a channel of
+ avoiding using the channel or adjacent channels in
+ accordance with the bandwidth. Range: 1 to 60 (minutes)."
+ ::= { brzaccVLDFSParameters 4 }
+
+
+ brzaccVLDFSSuWaitingOption OBJECT-TYPE
+ SYNTAX INTEGER { disable (1) , enable (2), na(255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Defines whether the associated SUs should wait for this AU/BU
+ after it stopped transmitting due to radar detection, before
+ they starts scanning for other AUs/BUs."
+ ::= { brzaccVLDFSParameters 5 }
+
+
+ brzaccVLDFSClearRadarDetectedChannelsAfterReset OBJECT-TYPE
+ SYNTAX INTEGER { cancel (1), clearRadarChannels (2), na(255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Clear Radar Detected and Adjacent to Radar channels after unit reset.
+ Returns the unit to operate in default frequency."
+ ::= { brzaccVLDFSParameters 6 }
+
+ brzaccVLDFSRadarDetectionChannelsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BrzaccVLDFSRadarDetectionChannelsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Applicable only when DFS option is on.
+ Displays the current channels defined in the sub-band and their radar
+ detection status."
+ ::= { brzaccVLDFSParameters 7 }
+
+ brzaccVLDFSRadarDetectionChannelsEntry OBJECT-TYPE
+ SYNTAX BrzaccVLDFSRadarDetectionChannelsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ An entry in the brzaccVLDFSRadarDetectionChannelsTable."
+ INDEX { brzaccVLDFSChannelIdx }
+ ::= { brzaccVLDFSRadarDetectionChannelsTable 1 }
+
+ BrzaccVLDFSRadarDetectionChannelsEntry ::= SEQUENCE {
+ brzaccVLDFSChannelIdx INTEGER,
+ brzaccVLDFSChannelFrequency INTEGER,
+ brzaccVLDFSChannelRadarStatus INTEGER,
+ brzaccVLDFSChannelFrequencyNew DisplayString }
+
+ brzaccVLDFSChannelIdx OBJECT-TYPE
+ SYNTAX INTEGER (1..40)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only. Read-only.
+ The index of the entry in the
+ brzaccVLDFSRadarDetectionChannelsTable."
+ ::= { brzaccVLDFSRadarDetectionChannelsEntry 1 }
+
+ brzaccVLDFSChannelFrequency OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU with HW revision B and lower
+ (for units with HW revision C and higher replaced by
+ brzaccVLDFSChannelFrequency New to support a resolution
+ of 0.5 MHz).
+ The frequency in MHz of a channel in the DFS Radar
+ Detection Channels Table."
+ ::= { brzaccVLDFSRadarDetectionChannelsEntry 2 }
+
+ brzaccVLDFSChannelRadarStatus OBJECT-TYPE
+ SYNTAX INTEGER { radarFree (1),
+ adjacentToRadar (2),
+ radarDetected (3) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ The radar detection status of a channel in
+ brzaccVLDFSRadarDetectionChannelTable."
+ ::= { brzaccVLDFSRadarDetectionChannelsEntry 3 }
+
+ brzaccVLDFSChannelFrequencyNew OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU. The frequency of a channel in the
+ DFS Radar Detection Channels Table.
+ (Replaces brzaccVLDFSChannelFrequency to support a
+ resolution of 0.5 MHz for units with HW revision C and higher)."
+ ::= { brzaccVLDFSRadarDetectionChannelsEntry 4 }
+
+ brzaccVLDFSMinimumPulsesToDetect OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Defines the minimum number of pulses to detect a radar.
+ Range: 1 - 100."
+ ::= { brzaccVLDFSParameters 8 }
+
+
+brzaccVLDFSChannelReuseParameters OBJECT IDENTIFIER ::= {brzaccVLDFSParameters 9}
+
+ brzaccVLDFSChannelReuseOption OBJECT-TYPE
+ SYNTAX INTEGER { disable (1) , enable (2), na (255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Enabling/disabling the DFS Channel Reuse Algorithm.
+ Not applicable if DFS Option is not supported by the current Sub Band."
+ ::= { brzaccVLDFSChannelReuseParameters 1 }
+
+ brzaccVLDFSRadarActivityAssessmentPeriod OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Range: 1 to 12 (Houres)."
+ ::= { brzaccVLDFSChannelReuseParameters 2 }
+
+ brzaccVLDFSMaximumNumberOfDetectionsInAssessmentPeriod OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Range: 1 to 10 (Times)."
+ ::= { brzaccVLDFSChannelReuseParameters 3 }
+
+ brzaccVLCountryCodeLearningBySU OBJECT-TYPE
+ SYNTAX INTEGER { disable(1), enable(2), na(255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ Starting with 4.0 it is nor applicable for BA4900 and BreezeNET B.
+ Defines whether the SUs learn the country code of the AU."
+ ::= { brzaccVLFrequencyDefinition 12 }
+
+
+-- AUTOMATIC SUB BAND SELECT BEGIN
+
+ brzaccVLAutoSubBandSelect OBJECT IDENTIFIER ::= { brzaccVLFrequencyDefinition 15 }
+
+ brzaccVLAutoSubBandSelectedFreqSubset OBJECT-TYPE
+ SYNTAX INTEGER { setAllSelectedFreqsSubset(1), cancel (2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB with SW version 4.0 and higher.
+ Apply the selected subset. After the next reset the new
+ subset will be used for scanning."
+ ::= { brzaccVLAutoSubBandSelect 1 }
+
+ brzaccVLAutoSubBandFrequencySubsetTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BrzaccVLAutoSubBandFrequencySubsetEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB with SW version 4.0 and higher.
+ The Frequency Subset Table that includes all available
+ sub-bands and all the frequencies in these sub-bands."
+ ::= { brzaccVLAutoSubBandSelect 2 }
+
+ brzaccVLAutoSubBandFrequencySubsetEntry OBJECT-TYPE
+ SYNTAX BrzaccVLAutoSubBandFrequencySubsetEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB with SW version 4.0 and higher.
+ An entry in the Frequency Subset Table. "
+ INDEX { brzaccVLAutoSubBandFrequencySubsetBandIdx, brzaccVLAutoSubBandFrequencySubsetFrequencyIdx }
+ ::= { brzaccVLAutoSubBandFrequencySubsetTable 1 }
+
+ BrzaccVLAutoSubBandFrequencySubsetEntry ::= SEQUENCE {
+ brzaccVLAutoSubBandFrequencySubsetBandIdx INTEGER,
+ brzaccVLAutoSubBandFrequencySubsetFrequencyIdx INTEGER,
+ brzaccVLAutoSubBandFrequencySubsetActive INTEGER,
+ brzaccVLAutoSubBandFrequencySubsetFrequency DisplayString
+ }
+
+ brzaccVLAutoSubBandFrequencySubsetBandIdx OBJECT-TYPE
+ SYNTAX INTEGER (1..5)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB with SW version 4.0 and higher.
+ The index of the applicable Sub Band.
+ This is the Sub Band ID of the relevant entry in
+ the Country Dependent Parameters table.
+ Serves also as an index of the entry in the
+ Frequency subset Table."
+ ::= { brzaccVLAutoSubBandFrequencySubsetEntry 1 }
+
+ brzaccVLAutoSubBandFrequencySubsetFrequencyIdx OBJECT-TYPE
+ SYNTAX INTEGER (1..40)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB with SW version 4.0 and higher.
+ The index of the applicable frequency in the
+ applicable Sub Band.
+ Serves also as an index of the entry in the
+ Frequency subset Table."
+ ::= { brzaccVLAutoSubBandFrequencySubsetEntry 2 }
+
+
+ brzaccVLAutoSubBandFrequencySubsetActive OBJECT-TYPE
+ SYNTAX INTEGER {active (1) , notActive (2)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB with SW version 4.0 and higher.
+ The status of an entry in the Auto Sub Band Frequency subset Table.
+ The frequency of an active entry will be included in the
+ final list of frequencies to be used for scanning."
+ ::= { brzaccVLAutoSubBandFrequencySubsetEntry 3 }
+
+ brzaccVLAutoSubBandFrequencySubsetFrequency OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB with SW version 4.0 and higher.
+ The frequency in MHz of the entry in the Auto Sub Band Frequency Subset table."
+ ::= { brzaccVLAutoSubBandFrequencySubsetEntry 4 }
+
+
+-- AUTOMATIC SUB BAND SELECT END
+
+
+brzaccVLATPC OBJECT IDENTIFIER ::= {brzaccVLAirInterface 13}
+
+ brzaccVLAtpcOption OBJECT-TYPE
+ SYNTAX INTEGER { disable (1) , enable (2) , na (255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable all units.
+ Enabling/disabling the ATPC Algorithm."
+ ::= { brzaccVLATPC 1 }
+
+ brzaccVLDeltaFromMinSNRLevel OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable AU/BU only.
+ The Minimum SNR Level plus the value of this parameter define the
+ maximum desired level of the average SNR at the AU/BU.
+ If the ATPC Option is enabled, than if the received SNR is above
+ the maximum desired level, the AU/BU will transmit Power-Down
+ messages to the applicable SU/RB.
+ Range: 4 to 20 (dB)."
+ ::= { brzaccVLATPC 2 }
+
+ brzaccVLMinimumSNRLevel OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable AU/BU only.
+ Defines the minimum desired level of the average SNR at the AU/BU.
+ Below this level, if *AtpcOption is enabled, the AU/BU will transmit
+ ATPC Power-Up messages to the applicable SU/RB.
+ The *MinimumSNRLevel cannot be higher than *MaximumSNRLevel.
+ Range: 4 to 60 (dB)."
+ ::= { brzaccVLATPC 3 }
+
+
+ brzaccVLMinimumIntervalBetweenATPCMessages OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable AU/BU only.
+ The minimum interval between two consecutive AU/BU to SU/RB messages.
+ Range: 1 to 3600 (Sec)."
+ ::= { brzaccVLATPC 4 }
+
+
+
+ brzaccVLPowerLevelSteps OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable AU/BU only.
+ The step in dB that the SU/RB will use when receiving an ATPC
+ Power-Up/Power-Down message.
+ Range: 1 to 20 (dB)."
+ ::= { brzaccVLATPC 6 }
+
+brzaccVLCellDistanceParameters OBJECT IDENTIFIER ::= {brzaccVLAirInterface 15}
+
+ brzaccVLCellDistanceMode OBJECT-TYPE
+ SYNTAX INTEGER { automatic (1) , manual (2), na (255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable AU/BU only.
+ The selected mode of deciding on Cell Distance."
+ ::= { brzaccVLCellDistanceParameters 1 }
+
+ brzaccVLFairnessFactor OBJECT-TYPE
+ SYNTAX INTEGER { na (255)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable AU/BU only.
+ Not applicable to BreezeNET-B products for SW version below 4.0.
+ The percentage of the maximum distance that is taken into
+ account in the time slot calculation. Range: 0 to 100
+ (Percent). A value of 0 means the minimal slot size
+ (9 microseconds).
+ BreezeNET-B products with SW version below 4.0 return na."
+ ::= { brzaccVLCellDistanceParameters 2 }
+
+ brzaccVLMeasuredCellDistance OBJECT-TYPE
+ SYNTAX INTEGER {below-2-Km(1)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable AU/BU only.
+ The Maximum Cell Distance as calculated by the AU/BU.
+ Range: 0 to 54 (Kilometers)."
+ ::= { brzaccVLCellDistanceParameters 3 }
+
+ brzaccVLUnitWithMaxDistance OBJECT-TYPE
+ SYNTAX MacAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable AU only.
+ Not applicable to BreezeNET-B units.
+ The MAC address of the unit with the maximum distance
+ from the AU."
+ ::= { brzaccVLCellDistanceParameters 4 }
+
+ brzaccVLPerSuDistanceLearning OBJECT-TYPE
+ SYNTAX INTEGER { disable (1) , enable (2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Aplicable to AU only. Applicable only if Cell Distance Mode is
+ set to Automatic. When disabled, all SUs in the cell will use
+ for the ACK Timeout the computed distance of the farthest SU.
+ When enabled, each SU will use its own computed distance"
+ ::= { brzaccVLCellDistanceParameters 5 }
+
+ brzaccVLScanningMode OBJECT-TYPE
+ SYNTAX INTEGER { passive (1), active (2)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ The scanning mode. In cells where the DFS Option is enabled
+ Scanning Mode is forced to Passive."
+ ::= { brzaccVLAirInterface 16 }
+
+ brzaccVLAntennaGain OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. Read-write in units where
+ brzaccVLAntennaGainChange is supported.
+ Read-only in units where brzaccVLAntennaGainChange is not supported.
+ The net gain (including cable attenuation for detached antennas) of
+ the antenna.
+ Range: 0 - to Maximum EIRP defined by country code + 10 (dBi).
+ A value of -2 (this value is configurable only in factory)
+ means don't care.
+ A value of -1 (this value is configurable only in factory)
+ means that the unit will not transmit until the actual value
+ is configured."
+ ::= { brzaccVLAirInterface 17 }
+
+brzaccVLSpectrumAnalysisParameters OBJECT IDENTIFIER ::= {brzaccVLAirInterface 18}
+
+ brzaccVLSpectrumAnalysisChannelScanPeriod OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The period of staying on each channel for information gathering
+ when performing Spectrum analysis.
+ Range: 2-30 seconds."
+ ::= { brzaccVLSpectrumAnalysisParameters 1 }
+
+ brzaccVLSpectrumAnalysisScanCycles OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The number of scanning cycles when performing Spectrum Analysis.
+ Range: 1-100."
+ ::= { brzaccVLSpectrumAnalysisParameters 2 }
+
+ brzaccVLAutomaticChannelSelection OBJECT-TYPE
+ SYNTAX INTEGER { disable (1), enable (2), na (255)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Defines weather the AU/BU shall choose the most noise free channel
+ upon startup after spectrum analysis."
+ ::= { brzaccVLSpectrumAnalysisParameters 3 }
+
+ brzaccVLSpectrumAnalysisActivation OBJECT-TYPE
+ SYNTAX INTEGER { cancelOperation (1), activateNow (2)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Activates spectrum analysis, the unit is automatically reset upon
+ activation."
+ ::= { brzaccVLSpectrumAnalysisParameters 4 }
+
+ brzaccVLSpectrumAnalysisStatus OBJECT-TYPE
+ SYNTAX INTEGER { inactive (1), currentlyActive (2)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Defines weather the unit is currently under performing
+ a spectrum analysis process."
+ ::= { brzaccVLSpectrumAnalysisParameters 5 }
+
+ brzaccVLResetSpectrumCounters OBJECT-TYPE
+ SYNTAX INTEGER { cancelOperation (1), resetCounters (2)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Resets the spectrum analysis counters."
+ ::= { brzaccVLSpectrumAnalysisParameters 6 }
+
+ brzaccVLSpectrumAnalysisInformationTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BrzaccVLSpectrumAnalysisInformationEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The spectrum analysis information table."
+ ::= { brzaccVLSpectrumAnalysisParameters 7 }
+
+ brzaccVLSpectrumAnalysisInformationEntry OBJECT-TYPE
+ SYNTAX BrzaccVLSpectrumAnalysisInformationEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The spectrum analysis information table entry."
+ INDEX { brzaccVLSpectrumAnalysisInformationTableIdx }
+ ::= { brzaccVLSpectrumAnalysisInformationTable 1 }
+
+ BrzaccVLSpectrumAnalysisInformationEntry ::= SEQUENCE {
+ brzaccVLSpectrumAnalysisInformationTableIdx INTEGER,
+ brzaccVLSpectrumAnalysisInformationChannel DisplayString,
+ brzaccVLSpectrumAnalysisInformationSignalCount INTEGER,
+ brzaccVLSpectrumAnalysisInformationSignalSNR INTEGER,
+ brzaccVLSpectrumAnalysisInformationSignalWidth INTEGER,
+ brzaccVLSpectrumAnalysisInformationOFDMFrames INTEGER
+ }
+
+
+ brzaccVLSpectrumAnalysisInformationTableIdx OBJECT-TYPE
+ SYNTAX INTEGER (1..60)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ A read only table index for a Spectrum Analysis Information entry in the
+ Spectrum Analysis Information Table."
+ ::= { brzaccVLSpectrumAnalysisInformationEntry 1 }
+
+ brzaccVLSpectrumAnalysisInformationChannel OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The channels in the Spectrum Analysis Information Table.
+ If the unit is currently under spectrum analysis the channels would
+ be those on which the analysis is currently performed.
+ If the unit is in normal mode the channels would be the those on
+ which the last analysis was performed."
+ ::= { brzaccVLSpectrumAnalysisInformationEntry 2 }
+
+ brzaccVLSpectrumAnalysisInformationSignalCount OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The number of signals (excluding OFDM frames) detected in the channel.
+ If the unit is currently under spectrum analysis the count would
+ be of the analysis that is currently performed.
+ If the unit is in normal mode the count would be of the last
+ analysis performed."
+ ::= { brzaccVLSpectrumAnalysisInformationEntry 3 }
+
+ brzaccVLSpectrumAnalysisInformationSignalSNR OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The approximate SNR of the signals (excluding OFDM frames)
+ detected in the channel.
+ If the unit is currently under spectrum analysis the SNR would
+ be of the analysis that is currently performed.
+ If the unit is in normal mode the SNR would be of the last
+ analysis performed."
+ ::= { brzaccVLSpectrumAnalysisInformationEntry 4 }
+
+ brzaccVLSpectrumAnalysisInformationSignalWidth OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The average width of the signals (excluding OFDM frames)
+ detected in the channel.
+ If the unit is currently under spectrum analysis the width would
+ be of the analysis that is currently performed.
+ If the unit is in normal mode the width would be of the last
+ analysis performed."
+ ::= { brzaccVLSpectrumAnalysisInformationEntry 5 }
+
+ brzaccVLSpectrumAnalysisInformationOFDMFrames OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The number of OFDM frames detected in the channel.
+ If the unit is currently under spectrum analysis the count would
+ be of the analysis that is currently performed.
+ If the unit is in normal mode the count would be of the last
+ analysis performed."
+ ::= { brzaccVLSpectrumAnalysisInformationEntry 6 }
+
+ brzaccVLMaxNumOfAssociationsLimit OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ Not applicable to BreezeNET-B products.
+ Shows the limit for the number of SUs that can be associated
+ with the AU.
+ For AU-BS, AU-SA if Data Encryption is enabled, the upper
+ limit is 124, otherwise it is 512.
+ For AUS-BS, AUS-SA with SW version 4.0 and higher the upper limit
+ is 8 or 25 (via licensing).
+ For AUS-BS, AUS-SA with SW version below 4.0 the upper limit is 5.
+ BreezeNET-B products return 65535."
+ ::= { brzaccVLAirInterface 19 }
+
+brzaccVLDisassociate OBJECT IDENTIFIER ::= {brzaccVLAirInterface 20}
+
+ brzaccVLDisassociateAllSUs OBJECT-TYPE
+ SYNTAX INTEGER { cancelOperation (1), disassociateAllSUs(2)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ The AU shall disassociate all its associated units."
+ ::= { brzaccVLDisassociate 1 }
+
+ brzaccVLDisassociateSuByMacAddress OBJECT-TYPE
+ SYNTAX MacAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ The AU shall disassociate the SU with the configured MAC address."
+ ::= { brzaccVLDisassociate 2 }
+
+ brzaccVLTxControl OBJECT-TYPE
+ SYNTAX INTEGER { on (1), off(2), ethernetStatusControl(3)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Tx Control of the AU/BU.
+ Starting with version 4.0 it is run-time.
+ For SW version below 4.0 the unit reset itself.
+ If set to ethernetStatusControl, the unit will not transmit
+ if the Ethernet link is down.
+ This parameter can be configured only via the ethernet port."
+ ::= { brzaccVLAirInterface 21 }
+
+ brzaccVLLostBeaconsWatchdogThreshold OBJECT-TYPE
+ SYNTAX INTEGER ( 0 | 100..1000 )
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ The number of unsuccessful consecutive transmissions beacons
+ before Internal refresh is performed.
+ 0 means that the lost beacons watchdog is not
+ used and internal refresh is not performed."
+ ::= { brzaccVLAirInterface 22}
+
+ brzaccVLTransmitPower OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units with SW version 4.0 and higher.
+ The uniform transmit power for all modulation levels. For a specific
+ modulation level the effective transmit power (brzaccVLTxPower) is
+ the minimum between the uniform transmit power and the maximum
+ transmit power for that modulation level."
+ ::= { brzaccVLAirInterface 23 }
+
+ brzaccVLMaximumTxPower OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to only SU/RB with SW version 4.0 and higher.
+ The Maximum Transmit Power for all modulation levels.
+ The Maximum Transmit Power for a specific modulation level is the
+ minimum between this parameter and the hardware limitation for
+ that modulation level"
+ ::= { brzaccVLAirInterface 24 }
+
+ brzaccVLCountryCodeParameters OBJECT IDENTIFIER ::= {brzaccVLAirInterface 25}
+
+ brzaccVLCountryCodeReApply OBJECT-TYPE
+ SYNTAX INTEGER { reapply(1),cancel(2), na(255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Re-apply country code parameters."
+ ::= { brzaccVLCountryCodeParameters 1 }
+
+
+-- Service Params
+-- ==============
+ brzaccVLServiceParameters OBJECT IDENTIFIER ::= {breezeAccessVLMib 7}
+
+-- brzaccVLMirCirOption OBJECT-TYPE
+-- SYNTAX INTEGER {disable (1),
+-- enable (2),
+-- na (255)}
+-- MAX-ACCESS read-write
+-- STATUS current
+-- DESCRIPTION
+-- "Applicable to AU and SU. Read-only in SU.
+-- The setting in the AU enables/disables the MIR/CIR support
+-- feature for all SUs served by the AU."
+-- ::= { brzaccVLServiceParameters 1 }
+
+ brzaccVLMirDownlink OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ The Maximum Information Rate (MIR) from AU/BU to SU/RB.
+ MIR must be above brzaccVLCirDownlink value.
+ Range for set: 128 to 2,048 (Kbps) for SU-3 with SW version below 4.0,
+ 128 to 3,072 (Kbps) for SU-3 with SW version 4.0 and higher,
+ 128 to 3,968 (Kbps) for SU-6 with SW version less than 4.0,
+ 128 to 6,016 (Kbps) for SU-6 with SW version greater than 4.0,
+ 128 to 14,976 (Kbps) for SU-24,
+ 128 to 53,888 (Kbps) for SU-BD and SU-54,
+ 128 to 6,912 (Kbps) for RB-14,
+ 128 to 22,016 (Kbps) for RB-28,
+ 128 to 107,904 (Kbps) for RB-100.
+ 128 to 6,016 (Kbps) for SU-I.
+ The actual value (Get) will be the entered value rounded to the nearest
+ multiple of 128 (N*128)."
+ ::= { brzaccVLServiceParameters 2 }
+
+ brzaccVLMirUplink OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ The Maximum Information Rate (MIR) from SU/RB to AU/BU.
+ MIR must be above brzaccVLCirUplink value.
+ Range for set: 128 to 2,048 (Kbps) for SU-3,
+ 128 to 3,968 (Kbps) for SU-6 with SW version less than 4.0,
+ 128 to 4,096 (Kbps) for SU-6 with SW version greater than 4.0,
+ 128 to 14,976 (Kbps) for SU-24,
+ 128 to 53,888 (Kbps) for SU-BD and SU-54,
+ 128 to 6,912 (Kbps) for RB-14,
+ 128 to 22,016 (Kbps) for RB-28,
+ 128 to 107,904 (Kbps) for RB-100.
+ 128 to 2,048 (Kbps) for SU-I.
+ The actual value (Get) will be the entered value rounded to the nearest
+ multiple of 128 (N*128)."
+ ::= { brzaccVLServiceParameters 3 }
+
+
+ brzaccVLCirDownlink OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU only.
+ Not applicable to BreezeNET-B products.
+ The Committed Information Rate (CIR) from AU to SU.
+ CIR must be below brzaccVLMirDownlink value.
+ Range for Set:
+ 0 to 2,048 (Kbps) for SU-3 with SW version below 4.0,
+ 0 to 3,072 (Kbps) for SU-3 with SW version 4.0 and higher,
+ 0 to 3,968 (Kbps) for SU-6 with SW version less than 4.0,
+ 0 to 6,016 (Kbps) for SU-6 with SW version greater than 4.0
+ 0 to 14,976 (Kbps) for SU-24,
+ 0 to 45,056 (Kbps) for SU-BD and SU-54.
+ 0 to 6,016 (Kbps) for SU-I.
+ The actual value (Get) will be the entered value rounded to the
+ nearest multiple of 128 (N*128).
+ BreezeNET-B products will return 65535."
+ ::= { brzaccVLServiceParameters 4 }
+
+
+ brzaccVLCirUplink OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU only.
+ Not applicable to BreezeNET-B products.
+ The Committed Information Rate (CIR) from SU to AU.
+ CIR must be below brzaccVLMirUplink value.
+ Range for Set:
+ 0 to 2,048 (Kbps) for SU-3,
+ 0 to 3,968 (Kbps) for SU-6 with SW version less than 4.0,
+ 0 to 4,096 (Kbps) for SU-6 with SW version greater than 4.0,
+ 0 to 14,976 (Kbps) for SU-24,
+ 0 to 45,056 (Kbps) for SU-BD and SU-54.
+ 0 to 2,048 (Kbps) for SU-I.
+ The actual value (Get) will be the entered value rounded to the nearest
+ multiple of 128 (N*128).
+ BreezeNET-B products will return 65535."
+ ::= { brzaccVLServiceParameters 5 }
+
+
+ brzaccVLMaxDelay OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU only.
+ Not applicable to BreezeNET-B products.
+ The maximal time packets may be delayed by the
+ CIR\MIR mechanism. Above the configured maximal period
+ the packets are discarded.
+ Range: 300 to 10000 milliseconds.
+ BreezeNET-B products return 65535."
+ ::= { brzaccVLServiceParameters 6 }
+
+ brzaccVLMaxBurstDuration OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU and SU.
+ Not applicable to BreezeNET-B products.
+ The maximum time during which inactivity bonus time
+ can be accumulated for future burst transmissions.
+ Range: 0 to 2000 milliseconds.
+ BreezeNET-B products return 65535"
+ ::= { brzaccVLServiceParameters 7 }
+
+ brzaccVLGracefulDegradationLimit OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ Not applicable to BreezeNET-B products.
+ The maximum limit for activating the graceful
+ degradation algorithm.
+ Range: 0 to 70% rate of the CIR.
+ BreezeNET-B products return 255."
+ ::= { brzaccVLServiceParameters 8 }
+
+ brzaccVLMirOnlyOption OBJECT-TYPE
+ SYNTAX INTEGER {disable (1), enable (2), na (255)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ Not applicable to BreezeNET-B products.
+ When brzaccMirOnly is enabled, it overrides the CIR/MIR
+ algorithm for determining actual information rate and
+ forces the algorithm to operate with MIR parameter
+ settings only. When enabled, the Graceful Degradation
+ algorithm is disabled."
+ ::= { brzaccVLServiceParameters 9 }
+
+
+brzaccVLTrafficPrioritization OBJECT IDENTIFIER ::= {brzaccVLServiceParameters 10}
+
+brzaccVLTrafficPriVLAN OBJECT IDENTIFIER ::= {brzaccVLTrafficPrioritization 1}
+
+brzaccVLVLANPriorityThreshold OBJECT-TYPE
+ SYNTAX INTEGER (1..7)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ If the VLAN Priority's value of the frame is less than or equal to this
+ threshold the frame will get LOW priority, otherwise the frame will get
+ HIGH priority.
+ Untagged frames will get LOW priority"
+ ::= { brzaccVLTrafficPriVLAN 1 }
+
+
+brzaccVLTrafficPriIPToS OBJECT IDENTIFIER ::= {brzaccVLTrafficPrioritization 2}
+
+brzaccVLToSPrioritizationOption OBJECT-TYPE
+ SYNTAX INTEGER {disable(1), ipPrecedence(2), dSCP(3) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. Disable/Enable IP ToS prioritization and
+ choose the interpretation of the IP ToS field from IP header.
+ ipPrecedence(2): The IP ToS field is defined by RFC791. In this
+ case the prioritization will be done using the
+ Precedence sub-field of IP ToS. This sub-field
+ has 3 bits, so it can be between 0 and 7.
+ dSCP(3): The IP ToS field is defined by RFC2474. In this
+ case the prioritization will be done using the
+ DSCP sub-field. The size of the sub-field is 6 bits,
+ so the range is 0 to 63."
+ ::= { brzaccVLTrafficPriIPToS 1 }
+
+brzaccVLIPPrecedenceThreshold OBJECT-TYPE
+ SYNTAX INTEGER (0..7)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. The threshold of Precedence sub-field of IP ToS
+ field from IP Header (RFC791) to be used when the ToS Prioritization
+ Option is set to IP Precedence.
+ If the Precedence sub-field of a frame is less than or equal to this
+ threshold the frame will have LOW priority, otherwise it will get HIGH
+ priority."
+ ::= { brzaccVLTrafficPriIPToS 2 }
+
+brzaccVLIPDSCPThreshold OBJECT-TYPE
+ SYNTAX INTEGER (0..63)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. The threshold of DSCP sub-field of IP ToS
+ field from IP Header (RFC2474) to be used when ToS Prioritization
+ Option is set to DSCP.
+ If the DSCP sub-field of a frame is less than or equal to this
+ threshold the frame will have LOW priority, otherwise it will get
+ HIGH priority."
+ ::= { brzaccVLTrafficPriIPToS 3 }
+
+
+brzaccVLTrafficPriUdpTcpPortRange OBJECT IDENTIFIER ::= {brzaccVLTrafficPrioritization 3}
+
+brzaccVLUdpTcpPortRangePrioritizationOption OBJECT-TYPE
+ SYNTAX INTEGER {disable(1), udpOnly(2), tcpOnly(3), udpANDtcp(4) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. Disable/Enable Prioritization using UDP and/or
+ TCP Port Ranges.
+ udpOnly(2) : prioritization will be done only for UDP packets
+ tcpOnly(3) : prioritization will be done only for TCP packets
+ udpANDtcp(4): prioritization will be done for UDP and TCP packets"
+ ::= { brzaccVLTrafficPriUdpTcpPortRange 1 }
+
+brzaccVLUdpPortRangeConfig OBJECT IDENTIFIER ::= {brzaccVLTrafficPriUdpTcpPortRange 2}
+
+brzaccVLUdpPortPriRTPRTCP OBJECT-TYPE
+ SYNTAX INTEGER {rtpANDrtcp(1),rtpOnly(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicale to all units.
+ RTP/RTCP ports prioritization option for UDP packets.
+ rtpANDrtcp(1): the possible RTP and RTCP packet with destination port in the
+ defined port ranges will get HIGH priority
+ rtpOnly(2): only possible RTP packet (packet with even destination port )
+ with destination port in the defined port ranges will get HIGH
+ priority."
+ ::= { brzaccVLUdpPortRangeConfig 1 }
+
+brzaccVLUdpPortRangeNum OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. The number of entries in the UDP Port Range Table"
+ ::= { brzaccVLUdpPortRangeConfig 2 }
+
+brzaccVLUdpPortRangeTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BrzaccVLUdpPortRangeEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. A table of UDP port ranges use for prioritization.
+ The user can define up to 64 ranges.
+ An entry is empty if start is 65535 and end is 0"
+ ::= { brzaccVLUdpPortRangeConfig 3 }
+
+brzaccVLUdpPortRangeEntry OBJECT-TYPE
+ SYNTAX BrzaccVLUdpPortRangeEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. A UDP Port Ranges Table entry."
+ INDEX { brzaccVLUdpPortRangeIdx }
+ ::= { brzaccVLUdpPortRangeTable 1 }
+
+BrzaccVLUdpPortRangeEntry ::= SEQUENCE {
+ brzaccVLUdpPortRangeStart INTEGER,
+ brzaccVLUdpPortRangeEnd INTEGER,
+ brzaccVLUdpPortRangeIdx INTEGER
+ }
+
+brzaccVLUdpPortRangeStart OBJECT-TYPE
+ SYNTAX INTEGER(0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. Start port of an UDP Port Range"
+ ::= { brzaccVLUdpPortRangeEntry 1 }
+
+brzaccVLUdpPortRangeEnd OBJECT-TYPE
+ SYNTAX INTEGER(0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. End port of an UDP Port Range"
+ ::= { brzaccVLUdpPortRangeEntry 2 }
+
+brzaccVLUdpPortRangeIdx OBJECT-TYPE
+ SYNTAX INTEGER(1..64)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. UDP Port Range Entry's index "
+ ::= { brzaccVLUdpPortRangeEntry 3 }
+
+
+brzaccVLUdpPortRangeAdd OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..250))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. Add port range(s) to UDP Port Ranges Table.
+ Get operation will return the empty string.
+ A range is defined - or where is the Start
+ Port of the range and is the End Port. If only is
+ specified the range is -.
+ The value of and are between 0..65535.
+ The user can add several ranges using a comma to separate between ranges.
+ Example: 10-256,99,987-900"
+ ::= { brzaccVLUdpPortRangeConfig 4 }
+
+brzaccVLUdpPortRangeDelete OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..250))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. Delete port range(s) from UDP Port Ranges Table.
+ Get operation will return the empty string.
+ A range is defined - or where is the Start
+ Port of the range and is the End Port. If only is
+ specified the range is -.
+ The value of and are between 0..65535.
+ The user can delete several ranges using a comma to separate between
+ ranges.
+ Example: 10-256,99,987-900"
+ ::= { brzaccVLUdpPortRangeConfig 5 }
+
+brzaccVLUdpPortRangeDeleteAll OBJECT-TYPE
+ SYNTAX INTEGER { deleteAll(1), cancelOperation(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. Delete all entries form UDP Port Ranges Table.
+ Get operation will return 1"
+ ::= { brzaccVLUdpPortRangeConfig 6 }
+
+
+
+brzaccVLTcpPortRangeConfig OBJECT IDENTIFIER ::= {brzaccVLTrafficPriUdpTcpPortRange 3}
+
+brzaccVLTcpPortPriRTPRTCP OBJECT-TYPE
+ SYNTAX INTEGER {rtpANDrtcp(1),rtpOnly(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. RTP/RTCP ports prioritization option for TCP packets.
+ rtpANDrtcp(1): the possible RTP and RTCP packet with destination port
+ in the defined port ranges will get HIGH priority
+ rtpOnly(2): only possible RTP packet (packet with even destination port )"
+ ::= { brzaccVLTcpPortRangeConfig 1 }
+
+brzaccVLTcpPortRangeNum OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. The number of entries in the TCP Port Range Table"
+ ::= { brzaccVLTcpPortRangeConfig 2 }
+
+brzaccVLTcpPortRangeTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BrzaccVLTcpPortRangeEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of TCP Port Ranges use for prioritization.
+ The user can define up to 64 ranges.
+ An entry is empty if start is 65535 and end is 0"
+ ::= { brzaccVLTcpPortRangeConfig 3 }
+
+brzaccVLTcpPortRangeEntry OBJECT-TYPE
+ SYNTAX BrzaccVLTcpPortRangeEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. A TCP Port Ranges Table entry."
+ INDEX { brzaccVLTcpPortRangeIdx }
+ ::= { brzaccVLTcpPortRangeTable 1 }
+
+BrzaccVLTcpPortRangeEntry ::= SEQUENCE {
+ brzaccVLTcpPortRangeStart INTEGER,
+ brzaccVLTcpPortRangeEnd INTEGER,
+ brzaccVLTcpPortRangeIdx INTEGER
+ }
+
+brzaccVLTcpPortRangeStart OBJECT-TYPE
+ SYNTAX INTEGER(0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. Start port of a TCP Port Range"
+ ::= { brzaccVLTcpPortRangeEntry 1 }
+
+brzaccVLTcpPortRangeEnd OBJECT-TYPE
+ SYNTAX INTEGER(0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. End port of a TCP Port Range"
+ ::= { brzaccVLTcpPortRangeEntry 2 }
+
+brzaccVLTcpPortRangeIdx OBJECT-TYPE
+ SYNTAX INTEGER(1..64)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. TCP Port Range Entry's index"
+ ::= { brzaccVLTcpPortRangeEntry 3 }
+
+
+brzaccVLTcpPortRangeAdd OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..250))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. Add port range(s) to TCP Port Ranges Table.
+ Get operation will return the empty string.
+ A range is defined - or where is the Start
+ Port of the range and is the End Port. If only is specified
+ the range is -.
+ The value of and are between 0..65535.
+ The user can add several ranges using comma to separate between ranges.
+ Example: 10-256,99,987-900"
+ ::= { brzaccVLTcpPortRangeConfig 4 }
+
+brzaccVLTcpPortRangeDelete OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..250))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. Delete port range(s) from TCP Port Ranges Table.
+ Get operation will return the empty string.
+ A range is defined - or where is the Start
+ Port of the range and is the End Port. If only is specified
+ the range is -.
+ The value of and are between 0..65535.
+ The user can delete several ranges using comma to separate between ranges.
+ Example: 10-256,99,987-900"
+ ::= { brzaccVLTcpPortRangeConfig 5 }
+
+brzaccVLTcpPortRangeDeleteAll OBJECT-TYPE
+ SYNTAX INTEGER { deleteAll(1), cancelOperation(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. Delete all entries form TCP Port Ranges Table
+ Get operation will return 1"
+ ::= { brzaccVLTcpPortRangeConfig 6 }
+
+brzaccVLWirelessLinkPrioritization OBJECT IDENTIFIER ::= {brzaccVLTrafficPrioritization 4}
+
+brzaccVLWirelessLinkPrioritizationOption OBJECT-TYPE
+ SYNTAX INTEGER { disable(1), enable(2), na(255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable only to AU with a license for the Wireless Link Prioritization feature and to BU-100.
+ Enable/disable the traffic prioritization over the
+ Wireless Link"
+ ::= { brzaccVLWirelessLinkPrioritization 1}
+
+brzaccVLlowPriorityAIFS OBJECT-TYPE
+ SYNTAX INTEGER (3..254)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable only to AU with a license for the Wireless Link Prioritization feature and to BU-100.
+ Applicable only if the Wireless Link Prioritization Option is enabled.
+ Define the AIFS (Arbitration Inter-frame Space) that will be used
+ for transmitting Low Priority Traffic"
+ ::= { brzaccVLWirelessLinkPrioritization 2}
+
+brzaccVLHWRetriesHighPriority OBJECT-TYPE
+ SYNTAX INTEGER (0..14)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable only to AU with a license for the Wireless Link Prioritization feature and to BU-100.
+ Applicable only if the Wireless Link Prioritization Option is enabled.
+ Defines the Maximum number of HW Retries for a unicast data packet
+ that has High Priority"
+ ::= { brzaccVLWirelessLinkPrioritization 3}
+
+brzaccVLHWRetriesLowPriority OBJECT-TYPE
+ SYNTAX INTEGER (0..14)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable only to AU with a license for the Wireless Link Prioritization feature and to BU-100.
+ Applicable only if the Wireless Link Prioritization Option is enabled.
+ Defines the Maximum number of HW Retries for a unicast data packet
+ that has Low Priority"
+ ::= { brzaccVLWirelessLinkPrioritization 4}
+
+brzaccVLAUBurstDurationHighPriority OBJECT-TYPE
+ SYNTAX INTEGER (0..40)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable only to AU with a license for the Wireless Link Prioritization feature and to BU-100.
+ Applicable only if the Wireless Link Prioritization Option is enabled.
+ Defines the Maximum duration of burst that can be done by AU with
+ High Priority packets.
+ The time is given in 250 microseconds units"
+ ::= { brzaccVLWirelessLinkPrioritization 5}
+
+brzaccVLAUBurstDurationLowPriority OBJECT-TYPE
+ SYNTAX INTEGER (0..40)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable only to AU with a license for the Wireless Link Prioritization feature and to BU-100.
+ Applicable only if the Wireless Link Prioritization Option is enabled.
+ Defines the Maximum duration of burst that can be done by AU
+ with Low Priority packets.
+ The time is given in 250 microseconds units"
+ ::= { brzaccVLWirelessLinkPrioritization 6}
+
+brzaccVLSUBurstDurationHighPriority OBJECT-TYPE
+ SYNTAX INTEGER (0..40)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable only to AU with a license for the Wireless Link Prioritization feature and to BU-100.
+ Applicable only if the Wireless Link Prioritization Option is enabled.
+ Defines the Maximum duration of burst that can be done by SU/RB
+ with High Priority packets.
+ The parameter is configurable in AU and the SUs/RB will learn it
+ form AU/BU.
+ The time is given in 250 microseconds units"
+ ::= { brzaccVLWirelessLinkPrioritization 7}
+
+brzaccVLSUBurstDurationLowPriority OBJECT-TYPE
+ SYNTAX INTEGER (0..40)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable only to AU with a license for the Wireless Link Prioritization feature and to BU-100.
+ Applicable only if the Wireless Link Prioritization Option is enabled.
+ Defines the Maximum duration of burst that can be done by SU/RB
+ with High Priority packets.
+ The parameter is configurable in AU/BU and the SUs/RB will learn it
+ from AU/BU.
+ The time is given in 250 microseconds units"
+ ::= { brzaccVLWirelessLinkPrioritization 8}
+
+
+--DRAP BEGIN
+
+brzaccVLDrap OBJECT IDENTIFIER ::= { brzaccVLServiceParameters 11 }
+
+brzaccVLDrapSupport OBJECT-TYPE
+ SYNTAX INTEGER {disable(1), enable(2), na(255)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU. Not applicable to BreezeNET B products
+ Disable/Enable the DRAP feature"
+ ::= { brzaccVLDrap 1 }
+
+brzaccVLDrapUdpPort OBJECT-TYPE
+ SYNTAX INTEGER (8000..8200)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU when DRAP support is enabled.
+ Not applicable to BreezeNET B products.
+ The UDP port used for the DRAP server"
+ ::= { brzaccVLDrap 2 }
+
+brzaccVLDrapMaxNumberOfVoiceCalls OBJECT-TYPE
+ SYNTAX INTEGER (0..255)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU when DRAP support is enabled.
+ Not applicable to BreezeNET B products.
+ The maximum number of voice calls that can be supported by the AU"
+ ::= { brzaccVLDrap 3 }
+
+brzaccVLDrapTTL OBJECT-TYPE
+ SYNTAX INTEGER (1..255)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU when DRAP support is enabled.
+ Not applicable to BreezeNET B products.
+ The maximum time between two allocation requests"
+ ::= { brzaccVLDrap 4 }
+
+brzaccVLDrapNoOfActiveVoiceCalls OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU when DRAP support is enabled.
+ Not applicable to BreezeNET B products.
+ The current total number of active voice calls."
+ ::= { brzaccVLDrap 5 }
+
+
+--DRAP END
+
+brzaccVLLowPriorityTrafficMinimumPercent OBJECT-TYPE
+ SYNTAX INTEGER (0..100)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The minimum percent of the traffic rate that is allocated to the low priority traffic"
+ ::= { brzaccVLServiceParameters 12 }
+
+
+brzaccVLSUPMirDownlink OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ The Maximum Information Rate (MIR) from AU to SUP.
+ Range for set: 128 to 12,032 (Kbps).
+ The actual value (Get) will be the entered value rounded to the nearest
+ multiple of 128 (N*128)."
+ ::= { brzaccVLServiceParameters 13 }
+
+brzaccVLMIRThresholdPercent OBJECT-TYPE
+ SYNTAX INTEGER (0..100)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ MIR Threshold Percent"
+ ::= { brzaccVLServiceParameters 14 }
+
+-- User Filtering Params
+-- =====================
+ brzaccVLUserFilterParams OBJECT IDENTIFIER ::= {breezeAccessVLMib 8}
+
+ brzaccVLUserFilterOption OBJECT-TYPE
+ SYNTAX INTEGER { disable (1),
+ ipOnly (2),
+ userDefinedAddrOnly (3),
+ pPPoEOnly (4),
+ na (255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Defines user-filtering options.
+ disable: No filtering.
+ iPOnly: Only IP protocol frames pass.
+ userDefinedAddrOnly: Only ip frames to/from user defined IP
+ addresses pass.
+ pPPoE Only: Only PPPoE frames pass."
+ ::= { brzaccVLUserFilterParams 1 }
+
+ brzaccVLIpFilterTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BrzaccVLIpFilterEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ An IP Filter Table of up to 8 user defined addresses,
+ or address groups, to be used if the selected User
+ Filtering option is userDefinedAddrOnly."
+ ::= { brzaccVLUserFilterParams 2 }
+
+ brzaccVLIpFilterEntry OBJECT-TYPE
+ SYNTAX BrzaccVLIpFilterEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ An IP Filter Table entry."
+ INDEX { brzaccVLIpFilterIdx }
+ ::= { brzaccVLIpFilterTable 1 }
+
+ BrzaccVLIpFilterEntry ::= SEQUENCE {
+ brzaccVLIpID IpAddress,
+ brzaccVLMaskID IpAddress,
+ brzaccVLIpFilterRange INTEGER,
+ brzaccVLIpFilterIdx INTEGER
+ }
+
+ brzaccVLIpID OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ An IP address of an IP Filter Table entry."
+ ::= { brzaccVLIpFilterEntry 1 }
+
+ brzaccVLMaskID OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ An IP Mask of an IP Filter Table entry. Either a mask
+ or a range, but not both can be used to define an
+ address group. If the range is other than 0, than the mask is
+ ignored and only the range value is used to define the address group."
+ ::= { brzaccVLIpFilterEntry 2 }
+
+ brzaccVLIpFilterRange OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ An addresses range for the IP Filter Table entry. The
+ first address in the range is the IP address.
+ O means that the range is not used.
+ Either a mask or a range, but not both can be used to
+ define an address group.
+ If the range is other than 0, than the mask is ignored and
+ only the range value is used to define the address group.
+ Range: 0 to 255."
+ ::= { brzaccVLIpFilterEntry 3 }
+
+ brzaccVLIpFilterIdx OBJECT-TYPE
+ SYNTAX INTEGER (1..8)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ A table index for the IP Filter Table entry."
+ ::= { brzaccVLIpFilterEntry 4 }
+
+ brzaccVLDeleteOneUserFilter OBJECT-TYPE
+ SYNTAX INTEGER { deletefirstEntry (1), deletesecondEntry (2),
+ deletethirdEntry (3), deletefourthEntry (4),
+ deletefifthEntry (5), deletesixthEntry (6),
+ deleteseventhEntry(7), deleteeighthEntry (8),
+ cancelOperation (9), na (255) }
+
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Deletes a single selected entry from the IP Filter
+ Table."
+ ::= { brzaccVLUserFilterParams 3 }
+
+ brzaccVLDeleteAllUserFilters OBJECT-TYPE
+ SYNTAX INTEGER { deleteAll (1), cancelOperation (2),
+ na (255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Deletes all entries from the IP Filter Table."
+ ::= { brzaccVLUserFilterParams 4 }
+
+ brzaccVLDHCPUnicastOverrideFilter OBJECT-TYPE
+ SYNTAX INTEGER { disable (1), enable (2), na (255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Enables or disables the unicast DHCP messages,
+ overriding the IP Filtering option."
+ ::= { brzaccVLUserFilterParams 5 }
+
+
+
+-- Security Params
+-- ==================
+brzaccVLSecurityParameters OBJECT IDENTIFIER ::= {breezeAccessVLMib 9}
+
+ brzaccVLAuthenticationAlgorithm OBJECT-TYPE
+ SYNTAX INTEGER {openSystem(1) , sharedKey(2)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Enables/disables the authentication encryption option.
+ openSystem: Authentication messages are not encrypted.
+ sharedKey : Authentication messages are encrypted "
+ ::= { brzaccVLSecurityParameters 1 }
+
+ brzaccVLSUDefaultKeyID OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ The key to be used for encryption of authentication messages
+ and/or data.
+ Range: 1 to 4. "
+ ::= { brzaccVLSecurityParameters 2 }
+
+ brzaccVLDataEncryptionOption OBJECT-TYPE
+ SYNTAX INTEGER {disable(1) , enable(2)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Enables/disables the data encryption option. "
+ ::= { brzaccVLSecurityParameters 3 }
+
+ brzaccVLAUDefaultMulticastKeyID OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ The key to be used for encryption of multicasts and broadcasts."
+ ::= { brzaccVLSecurityParameters 4 }
+
+ brzaccVLSecurityMode OBJECT-TYPE
+ SYNTAX INTEGER {wep(1) , aesOCB(2), fips197(3)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. The fips197 option is applicable only to units with a license to
+ use FIPS 197 algorithm.
+ The encryption algorithm to be used for authentication messages
+ and/or data encryption."
+ ::= { brzaccVLSecurityParameters 5 }
+
+
+ brzaccVLAuthenticationPromiscuousMode OBJECT-TYPE
+ SYNTAX INTEGER {disable(1) , enable(2)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Enables/disable the promiscuous mode allowing authentication of
+ and communication with all SUs/RB regardless of their security
+ parameters."
+ ::= { brzaccVLSecurityParameters 6 }
+
+
+ brzaccVLKey1 OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(32))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Key number 1. Accessible only with SNMP Write Community String
+ (administrator password).
+ Valid values: 32 hexadecimal digits."
+ ::= { brzaccVLSecurityParameters 7 }
+
+ brzaccVLKey2 OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(32))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Key number 2. Accessible only with SNMP Write Community String
+ (administrator password).
+ Valid values: 32 hexadecimal digits."
+ ::= { brzaccVLSecurityParameters 8 }
+
+ brzaccVLKey3 OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(32))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Key number 3. Accessible only with SNMP Write Community String
+ (administrator password).
+ Valid values: 32 hexadecimal digits."
+ ::= { brzaccVLSecurityParameters 9 }
+
+ brzaccVLKey4 OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(32))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Key number 4. Accessible only with SNMP Write Community String
+ (administrator password).
+ Valid values: 32 hexadecimal digits."
+ ::= { brzaccVLSecurityParameters 10 }
+
+ brzaccVLSecurityModeSupport OBJECT-TYPE
+ SYNTAX INTEGER (0..7)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. Returns types of encryption that are supported.
+ 0 - no encryption
+ 1 - WEP
+ 2 - AES OCB
+ 3 - WEP and AES OCB
+ 4 - FIPS-197
+ 5 - FIPS-197 and WEP
+ 6 - FIPS-197 and AES OCB
+ 7 - FIPS-197, AES OCB and WEP"
+ ::= { brzaccVLSecurityParameters 12 }
+
+--brzaccVLSecurityPermission OBJECT IDENTIFIER ::= {brzaccVLSecurityParameters 12}
+--
+-- brzaccVLDataEncryptionPermission OBJECT-TYPE
+-- SYNTAX INTEGER {permitted(1), notPermitted(2)}
+-- MAX-ACCESS read-only
+-- STATUS current
+-- DESCRIPTION
+-- "."
+-- ::= { brzaccVLSecurityPermission 1 }
+--
+-- brzaccVLEncryptionByAESPermission OBJECT-TYPE
+-- SYNTAX INTEGER {permitted(1), notPermitted(2)}
+-- MAX-ACCESS read-only
+-- STATUS current
+-- DESCRIPTION
+-- "."
+-- ::= { brzaccVLSecurityPermission 2 }
+--
+--
+-- brzaccVLAuthenticationBySharedKeyAlgorithmPermission OBJECT-TYPE
+-- SYNTAX INTEGER {permitted(1), notPermitted(2)}
+-- MAX-ACCESS read-only
+-- STATUS current
+-- DESCRIPTION
+-- "."
+-- ::= { brzaccVLSecurityPermission 3 }
+
+
+-- Performance Params
+-- ==================
+brzaccVLPerformanceParams OBJECT IDENTIFIER ::= {breezeAccessVLMib 10}
+
+ brzaccVLRTSThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU and AU.
+ Not applicable to BreezeNET-B products.
+ The minimum frame size that requires an RTS/CTS handshake.
+ Range: For units bearing SW version 3.0 and above: 20 to 3400 bytes,
+ for previous SW versions 20 to 1600 bytes.
+ BreezeNET-B products return 65535."
+ ::= { brzaccVLPerformanceParams 1 }
+
+ brzaccVLMinContentionWindow OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU and AU.
+ For units bearing SW version 4.0 and above applicable to
+ BreezeNET-B products, for previous SW versions not applicable
+ to BreezeNET-B products.
+ The initial value to be used by the contention window calculation
+ algorithm.
+ Value must be 0 or power of 2 minus 1 (7,15,31...).
+ Range: 0 to 1023, excluding 1 and 3.
+ BreezeNET-B products with SW version below 4.0 return 65535."
+ ::= { brzaccVLPerformanceParams 3 }
+
+ brzaccVLMaxContentionWindow OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU and AU.
+ For units bearing SW version 4.0 and above applicable to
+ BreezeNET-B products, for previous SW versions not applicable
+ to BreezeNET-B products.
+ The maximum value to be used by the contention window calculation
+ algorithm.
+ Value must be power of 2 minus 1 (7,15,31...)
+ Range: 7 to 1023."
+ ::= { brzaccVLPerformanceParams 4 }
+
+ brzaccVLMaximumModulationLevel OBJECT-TYPE
+ SYNTAX INTEGER { level1 (1),
+ level2 (2),
+ level3 (3),
+ level4 (4),
+ level5 (5),
+ level6 (6),
+ level7 (7),
+ level8 (8)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ If the Adaptive Modulation algorithm is enabled, it sets the
+ Maximum Modulation Level to be used.
+ If The Modulation algorithm is disabled, it sets the Fixed
+ Modulation Level to be used.
+ The range is 1 to 8. 8 is not applicable for units with HW revision A."
+ ::= { brzaccVLPerformanceParams 5 }
+
+ brzaccVLMulticastModulationLevel OBJECT-TYPE
+ SYNTAX INTEGER { level1 (1),
+ level2 (2),
+ level3 (3),
+ level4 (4),
+ level5 (5),
+ level6 (6),
+ level7 (7),
+ level8 (8)
+ }
+
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ The modulation level for multicast and broadcast data frames.
+ The range is 1 to 8.
+ 8 is not applicable for units with HW revision A."
+ ::= { brzaccVLPerformanceParams 6 }
+
+ brzaccVLAvgSNRMemoryFactor OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The weight of history in average SNR calculation.
+ The higher is the value, the higher is the weight of history.
+ Range: -1 (Disregard History) to 32."
+ ::= { brzaccVLPerformanceParams 7 }
+
+ brzaccVLHardwareRetries OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Not applicable if Wireless Link Prioritization is enabled.
+ The maximum number of trials to transmit an unacknowledged
+ frame in each Hardware Retrial phase.
+ Range : 1 to 14."
+ ::= { brzaccVLPerformanceParams 8 }
+
+
+brzaccVLAdaptiveModulationParams OBJECT IDENTIFIER ::= {brzaccVLPerformanceParams 9}
+
+ brzaccVLAdaptiveModulationAlgorithmOption OBJECT-TYPE
+ SYNTAX INTEGER { disable (1) , enable (2), na (255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Enables/disables the adaptive modulation level decision mechanism."
+ ::= { brzaccVLAdaptiveModulationParams 1 }
+
+
+ brzaccVLSoftwareRetrySupport OBJECT-TYPE
+ SYNTAX INTEGER { disable (1) , enable (2), na (255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Read-only for units with version 2.0.
+ Not applicable for units with SW version 3.0 and higher.
+ The status of the Software Retry mechanism.
+ Enabled when the Adaptive Modulation algorithm is enabled and
+ the Burst Mode Option is disabled. Otherwise it is disabled."
+ ::= { brzaccVLAdaptiveModulationParams 2 }
+
+
+ brzaccVLNumOfSoftwareRetries OBJECT-TYPE
+ SYNTAX INTEGER { na (255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Read-only for units with version 2.0.
+ Not applicable for units with SW version 3.0 and higher.
+ The maximum number of times to use the Software Retry mechanism
+ when it is enabled."
+ ::= { brzaccVLAdaptiveModulationParams 3 }
+
+
+
+ brzaccVLMinIntervalBetweenAdaptiveModulationAlgorithmMessages OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable all units.
+ The minimum interval between two consecutive AU/BU to SU/RB messages.
+ Range: 1 to 3600 (Sec)."
+ ::= { brzaccVLAdaptiveModulationParams 4 }
+
+ brzaccVLAdaptiveModulationDecisionThresholds OBJECT-TYPE
+ SYNTAX INTEGER { normal (1) , high (2), na (255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Defines the setting of thresholds for the rate decision algorithm.
+ high (2) should typically be used when the SNR is lower than 13dB."
+ ::= { brzaccVLAdaptiveModulationParams 5 }
+
+brzaccVLBurstMode OBJECT IDENTIFIER ::= {brzaccVLPerformanceParams 10}
+
+ brzaccVLBurstModeOption OBJECT-TYPE
+ SYNTAX INTEGER { disable (1) , enable (2), blocked(3), na (255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Applicable only if Burst Mode Option is supported by country
+ specific parameters of the Sub Band.
+ Not applicable if Wireless Link Prioritization is enabled.
+ Enables/disable burst mode operation.
+ In SU/RB with HW Revision B or lower blocked(3) value is returned
+ when Security Mode is Wep , Data Encryption Option
+ is Enabled and Burst option is Enabled.
+ In AU/BU with HW Revision B or lower blocked(3) value is returned
+ when Dfs Option is Enabled and Burst mode is enabled."
+ ::= { brzaccVLBurstMode 1 }
+
+ brzaccVLBurstInterval OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Not applicable if Wireless Link Prioritization is enabled.
+ Burst mode interval in milliseconds.
+ Range: 1 to the maximum value as defined in the country
+ specific parameters of the Sub Band (milliseconds)."
+ ::= { brzaccVLBurstMode 2 }
+
+brzaccVLConcatenationParameters OBJECT IDENTIFIER ::= {brzaccVLPerformanceParams 11}
+
+ brzaccVLConcatenationOption OBJECT-TYPE
+ SYNTAX INTEGER { disable (1), enable (2), na (255)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Defines the Concatenation option."
+ ::= { brzaccVLConcatenationParameters 1 }
+
+ brzaccVLConcatenationMaximumNumberOfFrames OBJECT-TYPE
+ SYNTAX INTEGER (2..8)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units with SW version 3.X .
+ Not applicable for version 4.0 and higher.
+ Defines the maximum numbers of frames that can be concatenated.
+ Range:2 to 8 (frames)."
+ ::= { brzaccVLConcatenationParameters 2 }
+
+ brzaccVLConcatenationMaxFrameSize OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Defines the maximum size of a concatenated frame.
+ Range:
+ 256 to 2200 (bytes) for BreezeNET-B products BU/RB14 BU/RB28,
+ or for AU/SU with HW revision A or B.
+ 256 to 4032 (bytes) for AU/SU with HW Revision
+ C or higher and BreezeNET-B products BU/RB100."
+ ::= { brzaccVLConcatenationParameters 3 }
+
+
+-- Site Survey Params
+-- ==================
+brzaccVLSiteSurvey OBJECT IDENTIFIER ::= {breezeAccessVLMib 11}
+
+ brzaccVLAverageReceiveSNR OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ The average Signal to Noise Ratio of received frames."
+ ::= { brzaccVLSiteSurvey 1 }
+
+-- Traffic Counters
+-- ================
+brzaccVLTrafficStatistics OBJECT IDENTIFIER ::= {brzaccVLSiteSurvey 2}
+
+
+ brzaccVLResetTrafficCounters OBJECT-TYPE
+ SYNTAX INTEGER { reset (1),cancel(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Resets the traffic counters."
+ ::= { brzaccVLTrafficStatistics 1 }
+
+brzaccVLEthCounters OBJECT IDENTIFIER ::= {brzaccVLTrafficStatistics 2}
+brzaccVLWirelessLinkCounters OBJECT IDENTIFIER ::= {brzaccVLTrafficStatistics 3}
+brzaccVLWirelessLinkEvents OBJECT IDENTIFIER ::= {brzaccVLTrafficStatistics 4}
+
+brzaccVLPerModulationLevelCounters OBJECT IDENTIFIER ::= {brzaccVLTrafficStatistics 5}
+
+
+ brzaccVLResetPerModulationLevelCounters OBJECT-TYPE
+ SYNTAX INTEGER { resetCounters(1) , cancel (2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Resets the per-Modulation Level counters ."
+ ::= { brzaccVLPerModulationLevelCounters 1 }
+
+
+
+ brzaccVLSUPerModulationLevelCountersTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BrzaccVLSUPerModulationLevelCountersEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB.
+ Per Rate Counters table."
+ ::= { brzaccVLPerModulationLevelCounters 2 }
+
+ brzaccVLSUPerModulationLevelCountersEntry OBJECT-TYPE
+ SYNTAX BrzaccVLSUPerModulationLevelCountersEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB.
+ An entry in the Per modulation Counters table."
+ INDEX { brzaccVLSUPerModulationLevelCountersTableIdx }
+ ::= { brzaccVLSUPerModulationLevelCountersTable 1 }
+
+ BrzaccVLSUPerModulationLevelCountersEntry ::= SEQUENCE {
+ brzaccVLSUPerModulationLevelCountersTableIdx INTEGER,
+ brzaccVLSUPerModulationLevelCountersApplicableModLevel INTEGER,
+ brzaccVLSUPerModulationLevelCountersTxSuccess Counter32,
+ brzaccVLSUPerModulationLevelCountersTxFailed Counter32
+ }
+
+
+ brzaccVLSUPerModulationLevelCountersTableIdx OBJECT-TYPE
+ SYNTAX INTEGER (1..8)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB.
+ An index of an entry in the Per modulation level Counters table."
+ ::= { brzaccVLSUPerModulationLevelCountersEntry 1 }
+
+ brzaccVLSUPerModulationLevelCountersApplicableModLevel OBJECT-TYPE
+ SYNTAX INTEGER {
+ modLevel-1 (1),
+ modLevel-2 (2),
+ modLevel-3 (3),
+ modLevel-4 (4),
+ modLevel-5 (5),
+ modLevel-6 (6),
+ modLevel-7 (7),
+ modLevel-8 (8)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB.
+ The applicable modulation level of the entry in the Per
+ modulation level Counters table.
+ Modulation Level 8 is not applicable for units with HW revision A."
+ ::= { brzaccVLSUPerModulationLevelCountersEntry 2 }
+
+
+ brzaccVLSUPerModulationLevelCountersTxSuccess OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB.
+ The total number of successfully transmitted unicasts at the
+ applicable modulation level."
+ ::= { brzaccVLSUPerModulationLevelCountersEntry 3 }
+
+
+ brzaccVLSUPerModulationLevelCountersTxFailed OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB.
+ The total number of dropped frames at the applicable
+ Modulation Level."
+ ::= { brzaccVLSUPerModulationLevelCountersEntry 4 }
+
+
+ brzaccVLAverageModulationLevel OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB.
+ The average modulation level for successful transmission
+ (rounded to nearest integer) since last reset of the
+ Per Modulation Level counters.
+ Range: 1 to 8."
+ ::= { brzaccVLPerModulationLevelCounters 3 }
+
+ brzaccVLTotalRxFramesViaEthernet OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Total number of frames received via the Ethernet port."
+ ::= { brzaccVLEthCounters 1 }
+
+ brzaccVLTxWirelessToEthernet OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Total number of frames transmitted to the Ethernet port."
+ ::= { brzaccVLEthCounters 2 }
+
+brzaccVLTxFramesToWireless OBJECT IDENTIFIER ::= {brzaccVLWirelessLinkCounters 1}
+
+ brzaccVLAUBeaconsToWireless OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ The number of beacons transmitted to the wireless media."
+ ::= { brzaccVLTxFramesToWireless 1 }
+
+-- brzaccVLOtherMngFramesToWireless OBJECT-TYPE
+-- SYNTAX Counter32
+-- MAX-ACCESS read-only
+-- STATUS current
+-- DESCRIPTION
+-- "Applicable to AU and SU.
+-- The number of management frames transmitted to the wireless media.
+-- In AU, this count does not include Beacons."
+-- ::= { brzaccVLTxFramesToWireless 2 }
+
+ brzaccVLDataAndOtherMngFramesToWireless OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ The number of data and management frames transmitted to the
+ wireless media. The count includes one count for each data
+ frame transmitted successfully (excluding retransmissions)."
+ ::= { brzaccVLTxFramesToWireless 3 }
+
+ brzaccVLTotalTxFramesToWireless OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The number of frames transmitted to the wireless media.
+ The count includes one count for each data frame
+ that was transmitted successfully (excluding retransmissions),
+ and also the number of transmitted control and management frames,
+ including beacons."
+ ::= { brzaccVLTxFramesToWireless 4 }
+
+ brzaccVLTotalTransmittedUnicasts OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ The total number of unicast frames successfully transmitted
+ to the wireless media, excluding retransmissions."
+ ::= { brzaccVLTxFramesToWireless 5 }
+
+ brzaccVLTotalTransmittedConcatenatedFramesDouble OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all products.
+ The total number of double concatenated frames successfully transmitted
+ to the wireless media, excluding retransmissions."
+ ::= { brzaccVLTxFramesToWireless 6 }
+
+ brzaccVLTotalTransmittedConcatenatedFramesSingle OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all products.
+ The total number of double concatenated frames successfully transmitted
+ to the wireless media, excluding retransmissions."
+ ::= { brzaccVLTxFramesToWireless 7 }
+
+ brzaccVLTotalTransmittedConcatenatedFramesMore OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all products.
+ The total number of concatenated frames with more then two frames successfully
+ transmitted to the wireless media, excluding retransmissions."
+ ::= { brzaccVLTxFramesToWireless 8 }
+
+ brzaccVLTotalRxFramesFromWireless OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The total number of frames that were received
+ from the wireless media.
+ The count includes data and control and management
+ frames, including beacons received from the AU/BU.
+ The count does not include frames that were discarded
+ internally, bad frames and duplicate frames."
+ ::= { brzaccVLWirelessLinkCounters 2 }
+
+ brzaccVLTotalRetransmittedFrames OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The total number of retransmissions of data frames
+ (counts all unsuccessful transmissions/retransmissions)."
+ ::= { brzaccVLWirelessLinkCounters 3 }
+
+ brzaccVLFramesDropped OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The number of dropped frames.
+ The frames that were retransmitted to the extent
+ of the maximum allowed number of retransmissions
+ without being acknowledged.."
+ ::= { brzaccVLWirelessLinkCounters 4 }
+
+
+brzaccVLDataFramesSubmittedToBridge OBJECT IDENTIFIER ::= {brzaccVLWirelessLinkCounters 5}
+
+ brzaccVLFramesSubmittedViaHighQueue OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Frames submitted to the internal bridge via the High priority queue.
+ for transmission to the wireless media."
+ ::= { brzaccVLDataFramesSubmittedToBridge 1 }
+
+ brzaccVLFramesSubmittedViaMidQueue OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Frames submitted to the internal bridge via the Mid priority queue
+ for transmission to the wireless media."
+ ::= { brzaccVLDataFramesSubmittedToBridge 2 }
+
+ brzaccVLFramesSubmittedViaLowQueue OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Frames submitted to the internal bridge via the Low priority queue
+ for transmission to the wireless media."
+ ::= { brzaccVLDataFramesSubmittedToBridge 3 }
+
+ brzaccVLTotalNoOfDataFramesSubmitted OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The total number of data frames submitted to the internal bridge
+ for transmission to the wireless media."
+ ::= { brzaccVLDataFramesSubmittedToBridge 4 }
+
+
+ brzaccVLTotalRecievedDataFrames OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The total number of data frames received from the
+ wireless media, including duplicate frames."
+ ::= { brzaccVLWirelessLinkCounters 6 }
+
+ brzaccVLRecievedBadFrames OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The number of frames received from the wireless
+ media with errors (CRC errors)."
+ ::= { brzaccVLWirelessLinkCounters 7 }
+
+ brzaccVLNoOfDuplicateFramesDiscarded OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The number of frames discarded due to receiving multiple copies."
+ ::= { brzaccVLWirelessLinkCounters 8 }
+
+ brzaccVLNoOfInternallyDiscardedMirCir OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The number of data frames received from the Ethernet port that were
+ discarded by the MIR/CIR mechanism either to avoid exceeding the
+ maximum allowed information rate, or when the wireless link conditions
+ do not enable reaching the allowed rate."
+ ::= { brzaccVLWirelessLinkCounters 9 }
+
+ brzaccVLTotalRxConcatenatedFramesDouble OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The total number of double concatenated frames received
+ from the wireless media, including duplicate frames."
+ ::= { brzaccVLWirelessLinkCounters 10 }
+
+ brzaccVLTotalRxConcatenatedFramesSingle OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The total number of data fast frames single concatenated
+ frames received from the wireless media, including duplicate frames."
+ ::= { brzaccVLWirelessLinkCounters 11 }
+
+ brzaccVLTotalRxConcatenatedFramesMore OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The total number of data fast frames concatenated with more then two
+ frames received from the wireless media, including duplicate frames."
+ ::= { brzaccVLWirelessLinkCounters 12 }
+
+-- brzaccVLInternallyGeneratedFramesSubmittedToBridge OBJECT-TYPE
+-- SYNTAX Counter32
+-- MAX-ACCESS read-only
+-- STATUS current
+-- DESCRIPTION
+-- "Applicable to SU and AU. Read-only.
+-- The number of internally generated frames(wireless management and control frames)
+-- submitted to the bridge for transmission to the wireless media."
+-- ::= { brzaccVLWirelessLinkCounters 10 }
+
+
+brzaccVLTxEvents OBJECT IDENTIFIER ::= {brzaccVLWirelessLinkEvents 1}
+
+ brzaccVLDroppedFrameEvents OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The number of frames that were dropped because they were retransmitted
+ to the maximum allowed number of retransmissions without being
+ acknowledged."
+ ::= { brzaccVLTxEvents 1 }
+
+ brzaccVLFramesDelayedDueToSwRetry OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Not applicable for units with SW Version 3.0 and higher.
+ The number of frames that were delayed because the SW retry
+ algorithm was activated on a previous frame designated for the
+ same recipient."
+ ::= { brzaccVLTxEvents 2 }
+
+ brzaccVLUnderrunEvents OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The number of frames whose transmission was aborted because the rate
+ of submitting frames for transmission exceeded the available
+ transmission capability."
+ ::= { brzaccVLTxEvents 3 }
+
+ brzaccVLOthersTxEvents OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The number of Tx events due to problems other than those of
+ the other Tx Events counters."
+ ::= { brzaccVLTxEvents 4 }
+
+ brzaccVLTotalTxEvents OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The total number of Tx special events."
+ ::= { brzaccVLTxEvents 5 }
+
+brzaccVLRxEvents OBJECT IDENTIFIER ::= {brzaccVLWirelessLinkEvents 2}
+
+ brzaccVLPhyErrors OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units, only when DFS is enabled.
+ The number of unidentified signals."
+ ::= { brzaccVLRxEvents 1 }
+
+ brzaccVLCRCErrors OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The number of frames received from the wireless media containing
+ CRC errors."
+ ::= { brzaccVLRxEvents 2 }
+
+ brzaccVLOverrunEvents OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The number of frames that were discarded because the receive
+ rate exceeded the processing capability or the capacity of the
+ Ethernet port."
+ ::= { brzaccVLRxEvents 3 }
+
+ brzaccVLRxDecryptEvents OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The number of frames that were not received properly due to a
+ problem in the data decryption mechanism."
+ ::= { brzaccVLRxEvents 4 }
+
+ brzaccVLTotalRxEvents OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The total number of Rx special events."
+ ::= { brzaccVLRxEvents 5 }
+
+
+-- Associations Database
+--
+brzaccVLMacAddressDatabase OBJECT IDENTIFIER ::= {brzaccVLSiteSurvey 5}
+
+brzaccVLAUMacAddressDatabase OBJECT IDENTIFIER ::= {brzaccVLMacAddressDatabase 1}
+
+brzaccVLAUAdbResetAllModulationLevelCounters OBJECT-TYPE
+ SYNTAX INTEGER { reset (1), cancel (2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ To reset all the counters for all SUs/RB in the MAC Address Database."
+ ::= { brzaccVLAUMacAddressDatabase 1 }
+
+brzaccVLAUAdbTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BrzaccVLAUAdbEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ AU/BU MAC Address Database table."
+ ::= { brzaccVLAUMacAddressDatabase 2 }
+
+brzaccVLAUAdbEntry OBJECT-TYPE
+ SYNTAX BrzaccVLAUAdbEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ An entry in the AU/BU MAC Address Database table."
+ INDEX { brzaccVLAdbIndex }
+ ::= { brzaccVLAUAdbTable 1 }
+
+
+BrzaccVLAUAdbEntry ::= SEQUENCE {
+ brzaccVLAdbIndex INTEGER,
+ brzaccVLAdbMacAddress MacAddress,
+ brzaccVLAdbStatus INTEGER,
+ brzaccVLAdbSwVersion DisplayString,
+ brzaccVLAdbSNR INTEGER,
+ brzaccVLAdbMaxModulationLevel INTEGER,
+ brzaccVLAdbTxFramesTotal Counter32,
+ brzaccVLAdbDroppedFramesTotal Counter32,
+ brzaccVLAdbTxSuccessModLevel1 Counter32,
+ brzaccVLAdbTxSuccessModLevel2 Counter32,
+ brzaccVLAdbTxSuccessModLevel3 Counter32,
+ brzaccVLAdbTxSuccessModLevel4 Counter32,
+ brzaccVLAdbTxSuccessModLevel5 Counter32,
+ brzaccVLAdbTxSuccessModLevel6 Counter32,
+ brzaccVLAdbTxSuccessModLevel7 Counter32,
+ brzaccVLAdbTxSuccessModLevel8 Counter32,
+ brzaccVLAdbTxFailedModLevel1 Counter32,
+ brzaccVLAdbTxFailedModLevel2 Counter32,
+ brzaccVLAdbTxFailedModLevel3 Counter32,
+ brzaccVLAdbTxFailedModLevel4 Counter32,
+ brzaccVLAdbTxFailedModLevel5 Counter32,
+ brzaccVLAdbTxFailedModLevel6 Counter32,
+ brzaccVLAdbTxFailedModLevel7 Counter32,
+ brzaccVLAdbTxFailedModLevel8 Counter32,
+ brzaccVLAdbCirTx INTEGER,
+ brzaccVLAdbMirTx INTEGER,
+ brzaccVLAdbCirRx INTEGER,
+ brzaccVLAdbMirRx INTEGER,
+ brzaccVLAdbCirMaxDelay INTEGER,
+ brzaccVLAdbDistance INTEGER,
+ brzaccVLAdbHwRevision INTEGER,
+ brzaccVLAdbCpldVer DisplayString,
+ brzaccVLAdbCountryCode INTEGER,
+ brzaccVLAdbBootVer DisplayString,
+ brzaccVLAdbAtpcOption INTEGER,
+ brzaccVLAdbAdapModOption INTEGER,
+ brzaccVLAdbBurstModeOption INTEGER,
+ brzaccVLAdbConcatenationOption INTEGER,
+ brzaccVLAdbSecurityMode INTEGER,
+ brzaccVLAdbAuthOption INTEGER,
+ brzaccVLAdbDataEncyptOption INTEGER,
+ brzaccVLAdbAge INTEGER,
+ brzaccVLAdbUnitName DisplayString
+ }
+
+brzaccVLAdbIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..512)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ The index of an entry in the AU/BU MAC Address Database table."
+ ::= { brzaccVLAUAdbEntry 1 }
+
+brzaccVLAdbMacAddress OBJECT-TYPE
+ SYNTAX MacAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ The MAC Address of an SU/RB entry in the MAC Address Database
+ table."
+ ::= { brzaccVLAUAdbEntry 2 }
+
+brzaccVLAdbStatus OBJECT-TYPE
+ SYNTAX INTEGER { associated (1),
+ authenticated (2),
+ notAuthenticated (3) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ The status of the relevant SU/RB."
+ ::= { brzaccVLAUAdbEntry 3 }
+
+brzaccVLAdbSwVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ The SW version of the relevant SU/RB."
+ ::= { brzaccVLAUAdbEntry 4 }
+
+brzaccVLAdbSNR OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ The average Signal to Noise Ratio in dB of frames received by
+ the AU/BU from the relevant SU/RB."
+ ::= { brzaccVLAUAdbEntry 5 }
+
+brzaccVLAdbMaxModulationLevel OBJECT-TYPE
+ SYNTAX INTEGER { modLevel-1 (1),
+ modLevel-2 (2),
+ modLevel-3 (3),
+ modLevel-4 (4),
+ modLevel-5 (5),
+ modLevel-6 (6),
+ modLevel-7 (7),
+ modLevel-8 (8)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ The value configured in the relevant SU/RB for the Maximum Modulation
+ Level parameter.
+ Modulation Level 8 is not applicable for units with HW revision A."
+ ::= { brzaccVLAUAdbEntry 6 }
+
+brzaccVLAdbTxFramesTotal OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Counts the total number of unicast frames (excluding retransmissions)
+ that were successfully transmitted to the SU/RB over the wireless link."
+ ::= { brzaccVLAUAdbEntry 7 }
+
+brzaccVLAdbDroppedFramesTotal OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Counts the total number of frames intended to the SU/RB that
+ were dropped because they were retransmitted to the extent
+ of the maximum allowed number of retransmissions without
+ being acknowledged."
+ ::= { brzaccVLAUAdbEntry 8 }
+
+brzaccVLAdbTxSuccessModLevel1 OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Counts the total number of unicast frames (excluding retransmissions)
+ that were successfully transmitted to the SU/RB over the wireless link
+ using modulation level 1."
+ ::= { brzaccVLAUAdbEntry 9 }
+
+brzaccVLAdbTxSuccessModLevel2 OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Counts the total number of unicast frames (excluding retransmissions)
+ that were successfully transmitted to the SU/RB over the wireless link
+ using modulation level 2."
+ ::= { brzaccVLAUAdbEntry 10 }
+
+brzaccVLAdbTxSuccessModLevel3 OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Counts the total number of unicast frames (excluding retransmissions)
+ that were successfully transmitted to the SU/BU over the wireless link
+ using modulation level 3."
+ ::= { brzaccVLAUAdbEntry 11 }
+
+brzaccVLAdbTxSuccessModLevel4 OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Counts the total number of unicast frames (excluding retransmissions)
+ that were successfully transmitted to the SU/RB over the wireless link
+ using modulation level 4."
+ ::= { brzaccVLAUAdbEntry 12 }
+
+brzaccVLAdbTxSuccessModLevel5 OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Counts the total number of unicast frames (excluding retransmissions)
+ that were successfully transmitted to the SU/RB over the wireless link
+ using modulation level 5."
+ ::= { brzaccVLAUAdbEntry 13 }
+
+brzaccVLAdbTxSuccessModLevel6 OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Counts the total number of unicast frames (excluding retransmissions)
+ that were successfully transmitted to the SU/BU over the wireless link
+ using modulation level 6."
+ ::= { brzaccVLAUAdbEntry 14 }
+
+brzaccVLAdbTxSuccessModLevel7 OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Counts the total number of unicast frames (excluding retransmissions)
+ that were successfully transmitted to the SU/RB over the wireless link
+ using modulation level 7."
+ ::= { brzaccVLAUAdbEntry 15 }
+
+brzaccVLAdbTxSuccessModLevel8 OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Counts the total number of unicast frames (excluding retransmissions)
+ that were successfully transmitted to the SU/RB over the wireless link
+ using modulation level 8.
+ Not applicable for units with HW revision A."
+ ::= { brzaccVLAUAdbEntry 16 }
+
+brzaccVLAdbTxFailedModLevel1 OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Counts the total number of failures to successfully
+ transmit unicast frames intended to the SU/RB using modulation level 1."
+ ::= { brzaccVLAUAdbEntry 17 }
+
+brzaccVLAdbTxFailedModLevel2 OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Counts the total number of failures to successfully
+ transmit unicast frames intended to the SU/RB using modulation level 2."
+ ::= { brzaccVLAUAdbEntry 18 }
+
+brzaccVLAdbTxFailedModLevel3 OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Counts the total number of failures to successfully
+ transmit unicast frames intended to the SU/RB using modulation level 3."
+ ::= { brzaccVLAUAdbEntry 19 }
+
+brzaccVLAdbTxFailedModLevel4 OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Counts the total number of failures to successfully
+ transmit unicast frames intended to the SU/RB using modulation level 4."
+ ::= { brzaccVLAUAdbEntry 20 }
+
+brzaccVLAdbTxFailedModLevel5 OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Counts the total number of failures to successfully
+ transmit unicast frames intended to the SU/RB using modulation level 5."
+ ::= { brzaccVLAUAdbEntry 21 }
+
+brzaccVLAdbTxFailedModLevel6 OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Counts the total number of failures to successfully
+ transmit unicast frames intended to the SU/RB using modulation level 6."
+ ::= { brzaccVLAUAdbEntry 22 }
+
+brzaccVLAdbTxFailedModLevel7 OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Counts the total number of failures to successfully
+ transmit unicast frames intended to the SU/RB using modulation level 7."
+ ::= { brzaccVLAUAdbEntry 23 }
+
+brzaccVLAdbTxFailedModLevel8 OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Counts the total number of failures to successfully
+ transmit unicast frames intended to the SU/RB using modulation level 8.
+ Not applicable for units with HW revision A."
+ ::= { brzaccVLAUAdbEntry 24 }
+
+brzaccVLAdbCirTx OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU Only.
+ Not applicable to BreezeNET-B products. Read-only.
+ The value configured in the relevant SU for the CIR:
+ SU to AU parameter."
+ ::= { brzaccVLAUAdbEntry 25 }
+
+brzaccVLAdbMirTx OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ The value configured in the relevant SU/RB for the MIR:
+ SU/RB to AU/BU parameter."
+ ::= { brzaccVLAUAdbEntry 26 }
+
+brzaccVLAdbCirRx OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU Only.
+ Not applicable to BreezeNET-B products.
+ The value configured in the relevant SU for the CIR:
+ AU to SU parameter."
+ ::= { brzaccVLAUAdbEntry 27 }
+
+brzaccVLAdbMirRx OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ The value configured in the relevant SU/RB for the MIR:
+ AU/BU to SU/RB parameter."
+ ::= { brzaccVLAUAdbEntry 28 }
+
+brzaccVLAdbCirMaxDelay OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU Only.
+ Not applicable to BreezeNET-B products.
+ The value configured in the relevant SU for the CIR Maximum
+ Delay parameter."
+ ::= { brzaccVLAUAdbEntry 29 }
+
+brzaccVLAdbDistance OBJECT-TYPE
+ SYNTAX INTEGER {below-2-Km(1)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU Only.
+ The distance between the SU/RB and the AU/BU (In Kilometers)."
+ ::= { brzaccVLAUAdbEntry 30 }
+
+brzaccVLAdbHwRevision OBJECT-TYPE
+ SYNTAX INTEGER {hwRevisionA(1), hwRevisionB(2), hwRevisionC(3),
+ hwRevisionD(4), hwRevisionE(5), na(255)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU Only.
+ The SU/RB HW Revision."
+ ::= { brzaccVLAUAdbEntry 31 }
+
+brzaccVLAdbCpldVer OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU Only.
+ The SU/RB CPLD Version."
+ ::= { brzaccVLAUAdbEntry 32 }
+
+brzaccVLAdbCountryCode OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU Only.
+ The SU/RB supported country code."
+ ::= { brzaccVLAUAdbEntry 33 }
+
+brzaccVLAdbBootVer OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU Only.
+ The SU/RB Boot Version."
+ ::= { brzaccVLAUAdbEntry 34 }
+
+brzaccVLAdbAtpcOption OBJECT-TYPE
+ SYNTAX INTEGER {disable (1), enable (2), na (255)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU Only.
+ The SU/RB ATPC option configuration."
+ ::= { brzaccVLAUAdbEntry 35 }
+
+brzaccVLAdbAdapModOption OBJECT-TYPE
+ SYNTAX INTEGER {disable (1), enable (2), na (255)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU Only.
+ The SU/RB adaptive modulation option configuration."
+ ::= { brzaccVLAUAdbEntry 36 }
+
+brzaccVLAdbBurstModeOption OBJECT-TYPE
+ SYNTAX INTEGER {disable (1), enable (2), na (255)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU Only.
+ The SU/RB burst mode option configuration."
+ ::= { brzaccVLAUAdbEntry 37 }
+
+brzaccVLAdbConcatenationOption OBJECT-TYPE
+ SYNTAX INTEGER {disable (1), enable (2), na(255)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU Only.
+ The SU/RB concatenation option configuration."
+ ::= { brzaccVLAUAdbEntry 39 }
+
+brzaccVLAdbSecurityMode OBJECT-TYPE
+ SYNTAX INTEGER {wep(1), aes(2), fips197(3), na(255)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU Only.
+ The SU/RB security mode configuration."
+ ::= { brzaccVLAUAdbEntry 41 }
+
+brzaccVLAdbAuthOption OBJECT-TYPE
+ SYNTAX INTEGER {openSystem (1), sharedKey (2), na (255)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU Only.
+ The SU/RB authentication algorithm configuration."
+ ::= { brzaccVLAUAdbEntry 42 }
+
+brzaccVLAdbDataEncyptOption OBJECT-TYPE
+ SYNTAX INTEGER {disable (1), enable (2), na (255)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU Only.
+ The SU/RB data encryption option configuration."
+ ::= { brzaccVLAUAdbEntry 43 }
+
+brzaccVLAdbAge OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ The time since any packet was received from the relevant SU/RB."
+ ::= { brzaccVLAUAdbEntry 44 }
+
+brzaccVLAdbUnitName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ The unit name of the relevant SU/RB."
+ ::= { brzaccVLAUAdbEntry 45 }
+
+
+brzaccVLUpLinkQualityIndicator OBJECT IDENTIFIER ::= { brzaccVLSiteSurvey 6}
+
+brzaccVLMeasureUpLinkQualityIndicator OBJECT-TYPE
+ SYNTAX INTEGER { start (1) , cancel (2)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB.
+ Starts calculation of LQI.
+ The calculation will be for a period of 10 seconds."
+ ::= { brzaccVLUpLinkQualityIndicator 1 }
+
+
+brzaccVLReadUpLinkQualityIndicator OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB.
+ The results of the last LQI calculation.
+ Range: 1 to 8."
+ ::= { brzaccVLUpLinkQualityIndicator 2 }
+
+
+brzaccVLUpLinkQualityIndicatorStatus OBJECT-TYPE
+ SYNTAX INTEGER {fullTest(1) , limitedTest(2)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB Only.
+ Indicates the test conditions.
+ fullTest means that there are no limitations
+ on the range of available modulation levels, and that all modulation levels
+ from 1 to 8 can be used.
+ limitedTest indicates that the results may not indicate the true quality since
+ the available range is limited - by HW (HW Revision A),
+ or by the applicable parameters in the country code,
+ or by the configurable Maximum Modulation Level parameter."
+ ::= { brzaccVLUpLinkQualityIndicator 3 }
+
+-- AC pinpoint table end
+
+brzaccVLMacPinpoint OBJECT IDENTIFIER ::= {brzaccVLSiteSurvey 7}
+
+ brzaccVLMacPinpointTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BrzaccVLMacPinpointEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ A table that contains information about wireless device
+ used by a certain Ethernet station in order to
+ connect to the wireless network"
+ ::= { brzaccVLMacPinpoint 1 }
+
+ brzaccVLMacPinpointEntry OBJECT-TYPE
+ SYNTAX BrzaccVLMacPinpointEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only. An entry in the MAC Pinpoint Table.
+ Each entry contains an Ethernet station MAC address and the MAC
+ address of the wireless device used to connect it to the wireless
+ network"
+ INDEX { mptEthernetStationMACAddress }
+ ::= { brzaccVLMacPinpointTable 1 }
+
+ BrzaccVLMacPinpointEntry ::=
+ SEQUENCE {
+ mptEthernetStationMACAddress
+ MacAddress,
+ mptUnitMACAddress
+ MacAddress
+ }
+
+ mptEthernetStationMACAddress OBJECT-TYPE
+ SYNTAX MacAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ The MAC address of the Ethernet station. It is used as an
+ index in the MAC Pinpoint Table."
+ ::= { brzaccVLMacPinpointEntry 1 }
+
+ mptUnitMACAddress OBJECT-TYPE
+ SYNTAX MacAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only. The MAC address of the wireless
+ device used by the station with the MAC Address from the
+ index in order to access the wireless network."
+ ::= { brzaccVLMacPinpointEntry 2 }
+-- AC pinpoint table end
+
+-- GATEWAY TABLE BEGIN
+
+brzaccVLDrapGatewaysTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BrzaccVLDrapGatewayEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table provides information about Gateways supporting DRAP that are
+ registered at the AU"
+ ::= { brzaccVLSiteSurvey 8 }
+
+brzaccVLDrapGatewayEntry OBJECT-TYPE
+ SYNTAX BrzaccVLDrapGatewayEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A Drap Gateway Entry."
+ INDEX { brzaccVLDrapGatewayIndex }
+ ::= { brzaccVLDrapGatewaysTable 1 }
+
+BrzaccVLDrapGatewayEntry ::= SEQUENCE {
+ brzaccVLDrapGatewayIndex INTEGER,
+ brzaccVLDrapGatewayIP IpAddress,
+ brzaccVLDrapGatewayType INTEGER,
+ brzaccVLDrapGatewayNoOfActiveVoiceCalls INTEGER
+ }
+
+brzaccVLDrapGatewayIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..512)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Gateway Entry's Index"
+ ::= { brzaccVLDrapGatewayEntry 1 }
+
+brzaccVLDrapGatewayIP OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The IP address of the Gateway"
+ ::= { brzaccVLDrapGatewayEntry 2 }
+
+brzaccVLDrapGatewayType OBJECT-TYPE
+ SYNTAX INTEGER { vgDataVoice (4), vgData1Voice1 (5),
+ vgData4Voice2 (6), vgDataVoice2(7),
+ ngData4Wireless (11),
+ vgUnknown(255)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The Gateway type"
+ ::= { brzaccVLDrapGatewayEntry 3 }
+
+brzaccVLDrapGatewayNoOfActiveVoiceCalls OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current number of active voice calls handled by the Gateway"
+ ::= { brzaccVLDrapGatewayEntry 4 }
+
+-- GATEWAY TABLE END
+
+-- ****************************************************************************************
+-- TRAP defenitions:
+-- ****************************************************************************************
+
+brzaccVLTraps OBJECT IDENTIFIER ::= { breezeAccessVLMib 14 }
+
+brzaccVLTrapSUMacAddr OBJECT-TYPE
+ SYNTAX MacAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ SU/RB MAC Address."
+ ::= { brzaccVLTraps 1 }
+
+--brzaccVLTrapSNRQuality OBJECT-TYPE
+-- SYNTAX INTEGER
+-- MAX-ACCESS read-only
+-- STATUS current
+-- DESCRIPTION
+-- "Applicable to SU only.
+-- SNR of received signal."
+-- ::= { brzaccVLTraps 2 }
+
+brzaccVLTrapText OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Textual string for future use."
+ ::= { brzaccVLTraps 3 }
+
+brzaccVLTrapToggle OBJECT-TYPE
+ SYNTAX INTEGER{
+ on (1),
+ off (2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ An On/Off toggle status."
+ ::= { brzaccVLTraps 4 }
+
+brzaccVLTrapParameterChanged OBJECT-TYPE
+ SYNTAX INTEGER{ cirOrMir (1),
+ ipFilter (2),
+ vlan (4)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ A modification to one of the parameters related to CIR/MIR,
+ IP Filtering or VLAN."
+ ::= { brzaccVLTraps 5 }
+
+brzaccVLTrapAccessRights OBJECT-TYPE
+ SYNTAX INTEGER{ notLoggedIn (1),
+ readOnly (2),
+ installer (3),
+ administrator (4),
+ factory (5) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The access rights used for login."
+ ::= { brzaccVLTraps 6 }
+
+brzaccVLTrapLog OBJECT-TYPE
+ SYNTAX INTEGER{ telnetLogin (3),
+ telnetLogout (4) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Login or logout to the Monitor program via Telnet."
+ ::= { brzaccVLTraps 7 }
+
+brzaccVLTrapTelnetUserIpAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The IP address of a Telnet user."
+ ::= { brzaccVLTraps 8 }
+
+brzaccVLTrapRTx OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Retransmissions as a percentage of total transmissions."
+ ::= { brzaccVLTraps 9 }
+
+brzaccVLTrapFtpOrTftpStatus OBJECT-TYPE
+ SYNTAX INTEGER{
+ successful (1),
+ failed (2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The status of the last FTP/TFTP loading procedure."
+ ::= { brzaccVLTraps 10 }
+
+brzaccVLDFSMoveFreq OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU with HW revision B and lower
+ (for units with HW revision C and higher replaced by
+ brzaccVLTrapDFSMoveFreq New to support a resolution of 0.5 MHz).
+ The new frequency in MHz after detecting radar on a previous channel."
+ ::= { brzaccVLTraps 11 }
+
+brzaccVLDFSMoveFreqNew OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU.
+ The new frequency in MHz after detecting radar on a previous channel.
+ (Replaces brzaccVLDFSMoveFreq to support a resolution of 0.5 MHz for
+ units with HW revision C and higher)."
+ ::= { brzaccVLTraps 12 }
+
+
+brzaccVLEthBroadcastThresholdExceeded OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The number of packets that are dropped by the ethernet broadcast/multicast limiter."
+ ::= { brzaccVLTraps 13 }
+
+
+brzaccVLTrapSubscriberType OBJECT-TYPE
+ SYNTAX INTEGER{ unknownSubscriberType(0),
+ su-3(3) , su-6(6) , rb-14(14),
+ su-24(24), rb-28(28), su-54(54),
+ rb-100(100) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AUS only.
+ The type of subscriber that was rejected by AUS"
+ ::= { brzaccVLTraps 14 }
+
+
+brzaccVLTrapMACAddress OBJECT-TYPE
+ SYNTAX MacAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to BU/RB only.
+ The MAC address of the BNET B unit whose type has been changed"
+ ::= { brzaccVLTraps 15 }
+
+brzaccVLNewUnitTypeTrap OBJECT-TYPE
+ SYNTAX INTEGER { bu(1), rb(2) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to BU/RB only.
+ The new type of the BNET B unit."
+ ::= { brzaccVLTraps 16 }
+
+brzaccVLTrapSWVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The SW version of the SU that tries to associate
+ with a station that has Wireless Link Prioritization Enabled"
+ ::= { brzaccVLTraps 17 }
+
+--
+-- Private Traps for BreezeAccessVL
+--
+
+brzaccVLSUassociatedAUTRAP NOTIFICATION-TYPE
+ OBJECTS
+ {
+ brzaccVLTrapSUMacAddr -- SU MAC address
+ }
+ STATUS current
+ DESCRIPTION
+ "An AU/BU trap indicating a new association with an SU/RB."
+ ::= { brzAccessVLProducts 2 }
+
+brzaccVLAUdisassociatedTRAP NOTIFICATION-TYPE
+ OBJECTS
+ {
+ brzaccVLTrapSUMacAddr --Unit MAC address
+ }
+ STATUS current
+ DESCRIPTION
+ "An AU/BU trap indicating that an SU/RB has been disassociated
+ from the AU.
+ The AU/BU decides that an SU/RB has been disassociated from it and remove it
+ from the ADB after receiving from another AU/BU a SNAP frame with the SU/RB
+ MAC address.
+ The SNAP frame indicating a network topology change where the SU/RB has
+ associated with another AU/BU will be received if both AUs/BUs are
+ connected to the same Ethernet backbone."
+ ::= { brzAccessVLProducts 3 }
+
+brzaccVLAUagingTRAP NOTIFICATION-TYPE
+ OBJECTS
+ {
+ brzaccVLTrapSUMacAddr -- Unit MAC address
+ }
+ STATUS current
+ DESCRIPTION
+ "An AU/BU trap indicating that the unit association was aged out
+ and removed from the Association database following its failure
+ to acknowledge a specified number of consecutive frames."
+ ::= { brzAccessVLProducts 4 }
+
+brzaccVLSUassociatedTRAP NOTIFICATION-TYPE
+ OBJECTS
+ {
+-- brzaccVLLastAUMacAddress, Old AU mac address
+ brzaccVLAssociatedAU -- New AU mac address
+-- brzaccVLTrapLastSNRQuality, Average SNR with old AU
+ }
+ STATUS current
+ DESCRIPTION
+ "An SU/RB trap indicating association with an AU/BU.
+ In addition to the MAC address information of the AU/BU, the
+ trap also includes information on the average SNR of frames
+ received from the AU/BU."
+ ::= { brzAccessVLProducts 6 }
+
+brzaccVLAUwirelessQualityTRAP NOTIFICATION-TYPE
+ OBJECTS
+ {
+ brzaccVLTrapToggle,
+ brzaccVLTrapRTx
+ }
+ STATUS current
+ DESCRIPTION
+ "An AU/BU trap, indicating that the quality of the wireless
+ link (retransmissions rate) has changed and dropped below (Off) or increased
+ above (On) a threshold , defined by the *brzaccVLWirelessTrapThreshold.
+ The threshold for AU/BU is a percentage of retransmissions."
+ ::= { brzAccessVLProducts 20 }
+
+brzaccVLPowerUpFromReset NOTIFICATION-TYPE
+ OBJECTS
+ {
+ brzaccVLUnitMacAddress -- Unit MAC address
+ }
+ STATUS current
+ DESCRIPTION
+ "An AU/BU trap indicating power up after Reset."
+ ::= { brzAccessVLProducts 101 }
+
+brzaccVLTelnetStatusTRAP NOTIFICATION-TYPE
+ OBJECTS
+ {
+ brzaccVLTrapLog,
+ brzaccVLTrapAccessRights,
+ brzaccVLTrapTelnetUserIpAddress
+ }
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ A trap indicating that a log-in or log-out has been performed
+ via Telnet. Includes the log-in access
+ right and the IP address of the PC performing Telnet."
+ ::= { brzAccessVLProducts 102 }
+
+brzaccVLParameterChangedTRAP NOTIFICATION-TYPE
+ OBJECTS
+ {
+ brzaccVLTrapParameterChanged
+ }
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. A trap indicating a change in a CIR/MIR, IP Filter
+ or VLAN parameter."
+ ::= { brzAccessVLProducts 103 }
+
+brzaccVLLoadingStatusTRAP NOTIFICATION-TYPE
+ OBJECTS
+ {
+ brzaccVLTrapFtpOrTftpStatus,
+ brzaccVLUnitMacAddress
+ }
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ A trap indicating that last FTP/TFTP loading process has been
+ finished successfully or failed. "
+ ::= { brzAccessVLProducts 104 }
+
+brzaccVLPromiscuousModeTRAP NOTIFICATION-TYPE
+ OBJECTS
+ {
+ brzaccVLTrapToggle,
+ brzaccVLUnitMacAddress
+ }
+ STATUS current
+ DESCRIPTION
+ "An AU/BU trap, indicating that the AU/BU In (On) Promiscuous Mode or
+ out (Off) Promiscuous Mode."
+ ::= { brzAccessVLProducts 105 }
+
+brzaccVLDFSRadarDetecetedTRAP NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "DFS: Applicable to AU/BU only.
+ A trap indicating that a radar was detected. "
+ ::= { brzAccessVLProducts 106 }
+
+brzaccVLDFSFrequcnyTRAP NOTIFICATION-TYPE
+ OBJECTS
+ {
+ brzaccVLDFSMoveFreq,
+ brzaccVLDFSMoveFreqNew
+ }
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ A trap indicating that the unit moved to a new frequency. "
+ ::= { brzAccessVLProducts 107 }
+
+brzaccVLDFSNoFreeChannelsExistsTRAP NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ A trap indicating that a radar was detected and there is no
+ free channel. "
+ ::= { brzAccessVLProducts 108 }
+
+brzaccVLEthBroadcastMulticatLimiterTRAP NOTIFICATION-TYPE
+ OBJECTS
+ {
+ brzaccVLEthBroadcastThresholdExceeded
+ }
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. The trap is send if the
+ ethernet broadcast filter threshold is exceeded
+ and it contains the number of dropped packets."
+ ::= { brzAccessVLProducts 109 }
+
+brzaccVLAUSUnsupportedSubscriberTypeTRAP NOTIFICATION-TYPE
+ OBJECTS
+ {
+ brzaccVLTrapSUMacAddr,
+ brzaccVLTrapSubscriberType
+ }
+ STATUS current
+ DESCRIPTION
+ "Applicable to AUS only.
+ This trap is generated when a subscriber with unsupported type tries to associate to AUS.
+ The AUS supports only SU-3 and SU-6.
+ The first variable of the trap is the subscriber MAC Address.
+ The second variable is the type of subscriber"
+ ::= { brzAccessVLProducts 110 }
+
+
+brzaccVLUnitTypeChangedTRAP NOTIFICATION-TYPE
+ OBJECTS
+ {
+ brzaccVLTrapMACAddress,
+ brzaccVLNewUnitTypeTrap
+ }
+ STATUS current
+ DESCRIPTION
+ "Applicable to BU/RB only.
+ This trap is generated when the user change the type of the BreezeNET B unit.
+ The RB can be converted in BU or vice versa.
+ The first variable of the trap is the unit MAC Address.
+ The second variable is the new type of the unit"
+ ::= { brzAccessVLProducts 111 }
+
+brzaccVLWLPrioritizationNotSupportedBySUTRAP NOTIFICATION-TYPE
+ OBJECTS
+ {
+ brzaccVLTrapSUMacAddr,
+ brzaccVLTrapSWVersion
+ }
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ This trap is generated when an SU/RB with a SW version below 4.0
+ that does not support Wireless Link Prioritization is associated
+ with an AU/BU with thw Wireless Link Prioritization Option enabled.
+ The first variable of the trap is the SU/RB MAC Address.
+ The second variable is the SW version of the SU/RB"
+ ::= { brzAccessVLProducts 112 }
+END
diff --git a/mibs/alvarion/ALVARION-DOT11-WLAN-TST-MIB b/mibs/alvarion/ALVARION-DOT11-WLAN-TST-MIB
new file mode 100755
index 0000000000..a2bc3ded71
--- /dev/null
+++ b/mibs/alvarion/ALVARION-DOT11-WLAN-TST-MIB
@@ -0,0 +1,1560 @@
+-- Title: BREEZECOM Private MIB
+-- This Private MIB supports all BREEZECOM products.
+-- This File includes support for all the BreezeAccess Product Line.
+--
+--
+-- Version: 4.5.16
+-- Date: Tuesday August 14 2007
+-- Comments: BREEZECOM agents also support the following Public MIBs:
+-- - MIB-II ( RFC1213 )
+-- - BRIDGE - MIB ( RFC1286 )
+
+
+-- Some MIB compilers require that the following lines
+-- for proper compilation
+
+--#include "rfc1155.smi"
+--#include "rfc1212.smi"
+
+ALVARION-DOT11-WLAN-TST-MIB DEFINITIONS ::= BEGIN
+
+ IMPORTS
+ enterprises
+ FROM RFC1155-SMI
+ OBJECT-TYPE
+ FROM RFC1212;
+
+-- mgmt OBJECT IDENTIFIER ::= { iso org(3) dod(6) internet(1) mgmt(2) }
+-- mib OBJECT IDENTIFIER ::= { mgmt 1 }
+-- directory OBJECT IDENTIFIER ::= { internet 1 }
+-- experimental OBJECT IDENTIFIER ::= { internet 3 }
+-- private OBJECT IDENTIFIER ::= { internet 4 }
+-- enterprises OBJECT IDENTIFIER ::= { private 1 }
+
+-- End of lines which might be needed to other MIB browsers
+-- for proper compilation
+
+
+
+ MacAddress ::= OCTET STRING (SIZE(6))
+ DisplayString ::= OCTET STRING
+
+
+-- breezecom OBJECT IDENTIFIER ::= { enterprises 710 }
+-- breezecomPrvRev OBJECT IDENTIFIER ::= { breezecom 3 }
+-- brzAccessMib OBJECT IDENTIFIER ::= { breezecomPrvRev 3}
+
+ alvarion OBJECT IDENTIFIER ::= { enterprises 12394 }
+ alvarionPrvRev OBJECT IDENTIFIER ::= { alvarion 3 }
+ brzLighteningMib OBJECT IDENTIFIER ::= { alvarionPrvRev 1 }
+ brzLighteningTest OBJECT IDENTIFIER ::= { alvarionPrvRev 2 }
+
+
+-- ****************************************************************************************
+-- ****************************************************************************************
+
+-- Service Params
+-- ==============
+
+ brzLighteGenParams OBJECT IDENTIFIER ::= { brzLighteningTest 1 }
+
+ brzLighteUnitName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteGenParams 1 }
+
+ brzLighteUnitType OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteGenParams 2 }
+
+ brzLighteUnitBand OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteGenParams 3 }
+
+ brzLighteUnitHwVer OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteGenParams 4 }
+
+ brzLighteUnitSwVer OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteGenParams 5 }
+
+ brzLighteUnitShadowVer OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteGenParams 6 }
+
+ brzLighteUnitFlashType OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteGenParams 7 }
+
+ brzLighteUnitFlashSize OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteGenParams 8 }
+
+
+ brzLighteUnitStatus OBJECT-TYPE
+ SYNTAX INTEGER {scaning(0), sync_waitForAdd(1), authenticating(2),
+ authenticated(3),associated(4),unknown(5)}
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteGenParams 10 }
+
+ brzLighteUnitAssocStatus OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteGenParams 11 }
+
+ brzLighteUnitBssId OBJECT-TYPE
+ SYNTAX MacAddress
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteGenParams 12 }
+
+ brzLighteUnitMacAddress OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteGenParams 13 }
+
+ brzLighteLockFlashUnitMacAddress OBJECT-TYPE
+ SYNTAX INTEGER {flashMacAdd_Lock(1), flashMacAdd_UnLock(2)}
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteGenParams 14 }
+
+ brzLighteUnitHWReset OBJECT-TYPE
+ SYNTAX INTEGER {resetHW(1), cancel(2)}
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteGenParams 15 }
+
+
+ brzLighteTxRxSettings OBJECT IDENTIFIER ::= { brzLighteningTest 2 }
+
+ brzLighteSetTransmitMode OBJECT-TYPE
+ SYNTAX INTEGER {Cont_tx_100_Data(1),tx_CW(3),Cont_tx_99_Data(4)}
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteTxRxSettings 1 }
+
+
+ brzLighteTxFrequencyCenter OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteTxRxSettings 2 }
+
+ brzLighteRxFrequencyCenter OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteTxRxSettings 3 }
+
+ brzLighteTransmitParams OBJECT IDENTIFIER ::= { brzLighteTxRxSettings 4 }
+
+ brzLighteTransmitPowerLevel OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteTransmitParams 1 }
+
+
+ brzLighteBitRate OBJECT-TYPE
+ SYNTAX INTEGER {mbps_6(6),mbps_9(9),mbps_12(12),
+ mbps_18(18),mbps_24(24),mbps_36(36),
+ mbps_48(48),mbps_54(54)}
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteTransmitParams 2 }
+
+
+ brzLighteTxVVAParams OBJECT IDENTIFIER ::= { brzLighteTransmitParams 3 }
+
+ brzLighteSetTxVVA OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteTxVVAParams 1 }
+
+
+ brzLighteVVATableStatus OBJECT-TYPE
+ SYNTAX INTEGER {unBurned(0),burned(1)}
+ ACCESS read-only
+ STATUS obsolete
+ DESCRIPTION
+ "."
+ ::= { brzLighteTxVVAParams 7 }
+
+ brzLightePoutAtTRSwitchRxMode OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteTxVVAParams 8 }
+
+ brzLighteNewVvaParams OBJECT IDENTIFIER ::= { brzLighteTxVVAParams 9 }
+
+ brzLighteSetOpenLoopState OBJECT-TYPE
+ SYNTAX INTEGER {cancel(0),setOpenLoop(1)}
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Set The unit to min pcdac power , vva 0 , open loop state -> for rev C only."
+ ::= { brzLighteNewVvaParams 1 }
+
+ brzLighteMaxPowerOpenLoop OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteNewVvaParams 2 }
+
+
+
+ brzLighteNewVvaTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF brzLighteNewVvaEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of up to 63 indexes."
+ ::= { brzLighteNewVvaParams 7 }
+
+ brzLighteNewVvaEntry OBJECT-TYPE
+ SYNTAX brzLighteNewVvaEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table entry."
+ INDEX { brzLighteNewVvaEntry }
+ ::= { brzLighteNewVvaTable 1 }
+
+ brzLighteNewVvaTableIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteNewVvaEntry 1 }
+
+ brzLighteNewVvaTableData OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteNewVvaEntry 2 }
+
+
+ brzLighteTxNewVVATableRequest OBJECT-TYPE
+ SYNTAX INTEGER {burn(0),load(1), cancel(2)}
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { brzLighteNewVvaParams 8 }
+
+
+ brzLighteMaxPowerAtMaxRate OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ ""
+ ::= { brzLighteNewVvaParams 9 }
+
+
+ brzLighteNewVVaTableStatus OBJECT-TYPE
+ SYNTAX INTEGER {vvaNotCalibrated(0) , vvaCalibrated(1)}
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " 0 = NOT Calibrated - use Hard Coded Table accordig to Hw Revision ,
+ 1 = VVa Table calibrated for 5.4 GHz Units."
+ ::= { brzLighteNewVvaParams 10 }
+
+
+ brzLighteFixVVaAttenuation_5_4GHz OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " ."
+ ::= { brzLighteNewVvaParams 11 }
+
+
+ brzLighteSetNewVVaTableToLinear OBJECT-TYPE
+ SYNTAX INTEGER {cancel(0) , setLinear(1)}
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ " ."
+ ::= { brzLighteNewVvaParams 12 }
+
+
+
+ brzLightePCDAC OBJECT IDENTIFIER ::= { brzLighteTransmitParams 4 }
+
+ brzLightePcdacTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF brzLightePcdacEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of up to 63 indexes."
+ ::= { brzLightePCDAC 1 }
+
+ brzLightePcdacEntry OBJECT-TYPE
+ SYNTAX brzLightePcdacEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table entry."
+ INDEX { brzLightePcdacTableIdx }
+ ::= { brzLightePcdacTable 1 }
+
+ brzLightePcdacEntry ::= SEQUENCE {
+ brzLightePcdacTableIdx INTEGER,
+ brzLightePcdacTableData INTEGER
+ }
+
+ brzLightePcdacTableIdx OBJECT-TYPE
+ SYNTAX INTEGER {pcdac_Min(0),pcdac_Max(1),pcdac_0_pcnt(2),pcdac_5_pcnt(3),
+ pcdac_10_pcnt(4),pcdac_20_pcnt(5),pcdac_30_pcnt(6),pcdac_50_pcnt(7),
+ pcdac_70_pcnt(8),pcdac_85_pcnt(9),pcdac_90_pcnt(10),pcdac_95_pcnt(11),pcdac_100_pcnt(12)}
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A table Index."
+ ::= { brzLightePcdacEntry 1 }
+
+
+ brzLightePcdacTableData OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLightePcdacEntry 2 }
+
+ brzLightePcdacTableCurrentChannel OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLightePCDAC 2 }
+
+
+ brzLightePcdacTableRequest OBJECT-TYPE
+ SYNTAX INTEGER {write_pcdac_Channels(0), write_pcdac_Values(1), cancel(2)}
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLightePCDAC 3 }
+
+ brzLightePcdacBurnToFlash OBJECT-TYPE
+ SYNTAX INTEGER {cancel (0), burn_to_flash(1)}
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLightePCDAC 4 }
+
+
+
+ brzLightePcdacChannelsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF brzLightePcdacChannelsEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of up to 10 indexes."
+ ::= { brzLightePCDAC 5 }
+
+ brzLightePcdacChannelsEntry OBJECT-TYPE
+ SYNTAX brzLightePcdacChannelsEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table entry."
+ INDEX { brzLightePcdacChannelsTableIdx }
+ ::= { brzLightePcdacChannelsTable 1 }
+
+ brzLightePcdacChannelsEntry ::= SEQUENCE {
+ brzLightePcdacChannelsTableIdx INTEGER,
+ brzLightePcdacChannelsTableData INTEGER
+ }
+
+ brzLightePcdacChannelsTableIdx OBJECT-TYPE
+ SYNTAX INTEGER {channel_0(0),channel_1(1),channel_2(2),
+ channel_3(3),channel_4(4),channel_5(5),
+ channel_6(6),channel_7(7),channel_8(8),channel_9(9)}
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A table Index."
+ ::= { brzLightePcdacChannelsEntry 1 }
+
+
+ brzLightePcdacChannelsTableData OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLightePcdacChannelsEntry 2 }
+
+ brzLighteTransmit OBJECT IDENTIFIER ::= { brzLighteTransmitParams 5 }
+
+
+ brzLighteSetTransmitOn OBJECT-TYPE
+ SYNTAX INTEGER {start_Tx(1),stop_Tx(2)}
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteTransmit 1 }
+
+ brzLighteforcePowerTx OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Enter the power multipled by 2."
+ ::= { brzLighteTransmitParams 6 }
+
+ brzLighteRereadProm OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteTransmitParams 7 }
+
+ brzLighteTypeOfTxPattern OBJECT-TYPE
+ SYNTAX INTEGER {FixedPattern(0) , randomPattern(1)}
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteTransmitParams 8 }
+
+ brzLighteTxFixedPattern OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Enter Exactly 8 Hex digits."
+ ::= { brzLighteTransmitParams 9 }
+
+ brzLighteTurboMode OBJECT-TYPE
+ SYNTAX INTEGER {normal(0) , turbo(1), half(2) , quarter(3)}
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteTransmitParams 10 }
+
+
+ brzLightenewTxGainOffset OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteTransmitParams 11 }
+
+ brzLighteGainStep OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteTransmitParams 12 }
+
+
+
+ brzLighteChannelMode OBJECT-TYPE
+ SYNTAX INTEGER {channel_57(0) ,channel_24(1) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteTransmitParams 13 }
+
+
+
+ brzLighteRawPowerDataRevisionC OBJECT IDENTIFIER ::= { brzLighteTransmitParams 14 }
+
+ brzLightePwr1_Xg1 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteRawPowerDataRevisionC 1 }
+
+ brzLightePwr2_Xg1 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteRawPowerDataRevisionC 2 }
+
+ brzLightePwr3_Xg1 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteRawPowerDataRevisionC 3 }
+
+ brzLightePwr4_Xg1 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteRawPowerDataRevisionC 4 }
+
+ brzLightePcd2_Delta OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteRawPowerDataRevisionC 5 }
+
+ brzLightePcd3_Delta OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteRawPowerDataRevisionC 6 }
+
+ brzLightePcd4_Delta OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteRawPowerDataRevisionC 7 }
+
+ brzLightePwr1_xg2 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteRawPowerDataRevisionC 8 }
+
+ brzLightePwr2_xg2 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteRawPowerDataRevisionC 9 }
+
+ brzLightePwr3_xg2 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteRawPowerDataRevisionC 10 }
+
+ brzLightePcd1 OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteRawPowerDataRevisionC 11 }
+
+ brzLighteTxGainForNormalMode OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteTransmitParams 15 }
+
+
+ brzLighteRecieveParams OBJECT IDENTIFIER ::= { brzLighteTxRxSettings 5 }
+
+
+ brzLighteRxVVA OBJECT IDENTIFIER ::= { brzLighteRecieveParams 2 }
+
+ brzLighteSetRxVVA OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteRxVVA 1 }
+
+ brzLighteTRSwitchControl OBJECT-TYPE
+ SYNTAX INTEGER {normal(1),rx_and_Tx_attenuated(2),tx_attenuated_state(3),rx_attenuated_state(4)}
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteTxRxSettings 6 }
+
+ brzLighteTRSwitchOption OBJECT-TYPE
+ SYNTAX INTEGER {disable(0), enable(1)}
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Enable/Disable the TR/Switch algorithm running in normal mode."
+ ::= { brzLighteTxRxSettings 7 }
+
+ brzLightePcktLen OBJECT-TYPE
+ SYNTAX INTEGER (1..4056)
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Packet length for OFDM 99% - Body length"
+ ::= { brzLighteTxRxSettings 8 }
+
+ brzLighteTests OBJECT IDENTIFIER ::= { brzLighteningTest 3 }
+ brzLighteBerPerTest OBJECT IDENTIFIER ::= { brzLighteTests 1 }
+ brzLighteBerPerParams OBJECT IDENTIFIER ::= { brzLighteBerPerTest 1 }
+
+ brzLighteBerPerParamsLength OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteBerPerParams 1 }
+
+ brzLighteBerPerParamsInterval OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteBerPerParams 2 }
+
+ brzLighteBerPerParamsRate OBJECT-TYPE
+ SYNTAX INTEGER {mbps_6(6),mbps_9(9),mbps_12(12),
+ mbps_18(18),mbps_24(24),mbps_36(36),
+ mbps_48(48),mbps_54(54)}
+ --,all_Rates(100)}
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteBerPerParams 3 }
+
+ brzLighteBerPerParamsPackets OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteBerPerParams 4 }
+
+
+ brzLighteResetBerPerCounters OBJECT-TYPE
+ SYNTAX INTEGER {cancel(0), reset(1)}
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteBerPerTest 2 }
+
+ brzLighteRunBerPerTest OBJECT-TYPE
+ SYNTAX INTEGER {run_Tx_ber_test(0), run_Rx_ber_test(1),stop_test(2)}
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteBerPerTest 3 }
+
+ brzLighteBerPerTestResults OBJECT IDENTIFIER ::= { brzLighteBerPerTest 4 }
+
+ brzLighteErrors OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Applicable to SU and AU. Read-only.
+ The number of frames received from the wireless
+ media with errors (CRC errors)."
+ ::= { brzLighteBerPerTestResults 1 }
+
+
+ brzLighteGoodPacketsRecieved OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Applicable to SU and AU. Read only.
+ The total number of frames that were received
+ from the wireless media.
+ The count includes data and control and management
+ frames, including beacons received from the AU.
+ The count does not include frames that were discarded
+ internally, bad frames and duplicate frames."
+ ::= { brzLighteBerPerTestResults 3 }
+
+ brzLighteRssiTest OBJECT IDENTIFIER ::= { brzLighteTests 2 }
+
+ brzLighteAvgRssiRecieved OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteRssiTest 1 }
+
+ brzLighteInRangeRecievedPackets OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteRssiTest 2 }
+
+ brzLighteOutOfRangeRecievedPackets OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteRssiTest 3 }
+
+
+
+ brzLighteRxRssiTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF brzLighteRxRssiEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of up to 63 indexes."
+ ::= { brzLighteRssiTest 4 }
+
+ brzLighteRxRssiEntry OBJECT-TYPE
+ SYNTAX brzLighteRxRssiEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table entry."
+ INDEX { brzLighteRxRssiTableIdx }
+ ::= { brzLighteRxRssiTable 1 }
+
+ brzLighteRxRssiEntry ::= SEQUENCE {
+ brzLighteRxRssiTableIdx INTEGER,
+ brzLighteRxRssiTableData INTEGER
+ }
+
+ brzLighteRxRssiTableIdx OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A table Index."
+ ::= { brzLighteRxRssiEntry 1 }
+
+ brzLighteRxRssiTableData OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteRxRssiEntry 2 }
+
+
+
+
+
+
+
+
+
+ brzLighteBistTest OBJECT IDENTIFIER ::= { brzLighteTests 3 }
+
+-- brzLighteRunBistTest OBJECT-TYPE
+-- SYNTAX INTEGER {runSdram_Test(1),runFlash_Test(2)}
+-- ACCESS read-write
+-- STATUS mandatory
+-- DESCRIPTION
+-- "."
+-- ::= { brzLighteBistTest 1 }
+--
+ brzLighteMemoryTestResult OBJECT-TYPE
+ SYNTAX INTEGER {pass(0),fail(1)}
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteBistTest 1 }
+
+ brzLighteEthernetMacRegTestResult OBJECT-TYPE
+ SYNTAX INTEGER {pass(0),fail(1)}
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteBistTest 2 }
+
+ brzLighteEthernetPhyRegTestResult OBJECT-TYPE
+ SYNTAX INTEGER {pass(0),fail(1)}
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteBistTest 3 }
+
+ brzLighteEthernetIntrptTestResult OBJECT-TYPE
+ SYNTAX INTEGER {pass(0),fail(1)}
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteBistTest 4 }
+
+
+ brzLightLedsTest OBJECT IDENTIFIER ::= { brzLighteTests 4 }
+
+ brzLighteTurnLedsOn OBJECT-TYPE
+ SYNTAX INTEGER {turnLedsOn(1),turnLedsOff(2)}
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLightLedsTest 1 }
+
+ brzLightDebugParams OBJECT IDENTIFIER ::= { brzLighteningTest 5 }
+--
+
+ brzLighteSwitchSettintTime OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLightDebugParams 1 }
+
+ brzLighteTxEndTo_Xlna_On OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLightDebugParams 2 }
+
+
+ brzLighteTxEndTo_Xpa_Off OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLightDebugParams 3 }
+
+ brzLighteTxFrameTo_Xpa_On OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLightDebugParams 4 }
+
+
+ brzLighteBeaconsRate OBJECT-TYPE
+ SYNTAX INTEGER {stopBeacons(1) , cancel(2)}
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLightDebugParams 5 }
+
+
+ brzLighteObSetting OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLightDebugParams 6 }
+
+ brzLighteDbSetting OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLightDebugParams 7 }
+
+ brzLighteXpdGain OBJECT-TYPE
+ SYNTAX INTEGER {val_0(0), val_6(6) , val12(12), val_18(18)}
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLightDebugParams 8 }
+
+ brzLighteToggleExternalPower OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLightDebugParams 9 }
+
+ brzLightePowerOverride OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLightDebugParams 10 }
+
+ brzLighteAntennaSwitch OBJECT-TYPE
+ SYNTAX INTEGER {switch(1) , cancel(2)}
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLightDebugParams 11 }
+
+ brzLighteRfGainBoost OBJECT-TYPE
+ SYNTAX INTEGER {val_0(0) , val_5(5) , val_10(10)}
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLightDebugParams 12 }
+
+ brzLighteConfigSet OBJECT-TYPE
+ SYNTAX INTEGER {regConfig(1) , cancel(2)}
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLightDebugParams 13 }
+
+ brzLighteTxPowerTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BrzLighteTxPowerEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table of up to 63 indexes."
+ ::= { brzLightDebugParams 14 }
+
+ brzLighteTxPowerEntry OBJECT-TYPE
+ SYNTAX BrzLighteTxPowerEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A table entry."
+ INDEX { brzLighteTxPowerTableIdx }
+ ::= { brzLighteTxPowerTable 1 }
+
+ brzLighteTxPowerEntry ::= SEQUENCE {
+ brzLighteTxPowerTableIdx INTEGER,
+ brzLighteTxPowerTablePcdac INTEGER
+ }
+
+ brzLighteTxPowerTableIdx OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A table Index."
+ ::= { brzLighteTxPowerEntry 1 }
+
+
+ brzLighteTxPowerTablePcdac OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "A table Index."
+ ::= { brzLighteTxPowerEntry 2 }
+
+
+
+
+ brzLighteFtpStatus OBJECT-TYPE
+ SYNTAX INTEGER {ftpActive(1) ,ftpSuccess(2), ftpFail(3)}
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLightDebugParams 15 }
+
+
+
+
+brzLightAuAvarageSNR OBJECT IDENTIFIER ::= { brzLightDebugParams 16 }
+
+ brzLighteAuAvgSNRSupport OBJECT-TYPE
+ SYNTAX INTEGER {disable (0) , enable(1)}
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLightAuAvarageSNR 1 }
+
+
+ brzLighteShowAuAvgSNR OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLightAuAvarageSNR 2 }
+
+
+
+ brzaccVLRtsCtsFailed OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "."
+ ::= { brzLightDebugParams 17 }
+
+
+ brzLighteHeatControl OBJECT-TYPE
+ SYNTAX INTEGER {normal_heat_operation(0), mac_roc_heater_on(1)}
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLightDebugParams 18 }
+
+
+ brzLightePaSleepControl OBJECT-TYPE
+ SYNTAX INTEGER {paSleepOfF(0), paSleepOn(1)}
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLightDebugParams 19 }
+
+
+ brzLighteFilterControl OBJECT-TYPE
+ SYNTAX INTEGER {lowband(0), upperBand(1)}
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "When FIL_SEL='0' Japanese lower band 4950 MHz is Selected
+ When FIL_SEL='1' Japanese upper band 5060 MHz is Selected."
+ ::= { brzLightDebugParams 20 }
+
+ brzLighteTx_frame_to_tx_d_start OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLightDebugParams 21 }
+
+
+ brzLighteTx_frame_to_xpaa_on OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLightDebugParams 22 }
+
+ brzLighteAteMode OBJECT-TYPE
+ SYNTAX INTEGER {normalMode(0),ateMode_Tx(1),ateMode_Rx(2)}
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteningTest 7 }
+
+
+
+
+
+brzLighteWCU OBJECT IDENTIFIER ::= { brzLighteningTest 9 }
+
+ brzLighteChallengeText OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteWCU 1 }
+
+
+ brzLighteCpldVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteWCU 2 }
+
+
+ brzLighteAuType OBJECT-TYPE
+ SYNTAX INTEGER {auNI(1) , auBS(2),suOnly(3)}
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteWCU 3 }
+
+ brzLighteHwMaxRate OBJECT-TYPE
+ SYNTAX INTEGER {rate6Mbps(1) , rate24Mbps(2),rate14Mbps(3),
+ rate28Mbps(4),rate54Mbps(5),rateUnLimitedMbps(6),
+ rate3Mbps(7), rateSUIMbps(9)}
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteWCU 4 }
+
+ brzLighteSysConfiguration OBJECT-TYPE
+ SYNTAX INTEGER {pToMultiPoint(1) , pToPoint(2)}
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteWCU 5 }
+
+
+ brzaccVLUnitHwOutputPower OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU and SU.
+ The output power to the antenna port supported by the unit"
+ ::= { brzLighteWCU 6 }
+
+
+ brzLighteChannelBandwidth OBJECT-TYPE
+ SYNTAX INTEGER {channelBW5Mhz(1) , channelBW10Mhz(2),channelBW20Mhz(3)}
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteWCU 7 }
+
+
+ brzLighteDeleteShadowVersion OBJECT-TYPE
+ SYNTAX INTEGER {deleteShadow(1) , cancel(2)}
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteWCU 8 }
+
+
+ brzLighteBridgeMode OBJECT-TYPE
+ SYNTAX INTEGER {mode_BD(1) , mode_1D(2), mode_4D(3)}
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteWCU 9 }
+
+
+brzLighteSecurityPermissions OBJECT IDENTIFIER ::= { brzLighteWCU 10 }
+
+ brzLighteSecurityPermission OBJECT-TYPE
+ SYNTAX INTEGER {forbidden(1) , permitted(2)}
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteSecurityPermissions 1 }
+
+
+ brzLighteDataEncryption OBJECT-TYPE
+ SYNTAX INTEGER {forbidden(1) , permitted(2)}
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteSecurityPermissions 2 }
+
+
+ brzLighteEncryptionByAes OBJECT-TYPE
+ SYNTAX INTEGER {forbidden(1) , permitted(2)}
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteSecurityPermissions 3 }
+
+
+
+ AuthenticationBySharedKeyAlgorithm OBJECT-TYPE
+ SYNTAX INTEGER {forbidden(1) , permitted(2)}
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteSecurityPermissions 4 }
+
+ brzLighteUnitConfigurationMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ AU_BS(1) , AU_SA(2) ,SU_6_1D(3),
+ SU_6_BD(4),SU_24_BD(5),BU_B14(6),
+ BU_B28(7) ,RB_B14(8) ,RB_B28(9),SU_BD(10),SU_54_BD(11),
+ SU_3_1D (12), SU_3_4D (13),
+ AUS_BS(14), AUS_SA(15),
+ AU_BS_4900(16), AU_SA_4900(17), SU_BD_4900(18),
+ BU_B100(19), RB_B100(20), SU_I(21),
+ AU_EZ(22),
+ setDefaults(100)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteWCU 11 }
+
+
+ brzLighteHwUnitType OBJECT-TYPE
+ SYNTAX INTEGER { AU(1) , SU(2) ,ATE_AU(3),ATE_SU(4) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteWCU 12 }
+
+
+ brzLighteSetConfigurationMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ AU_BS(1) , AU_SA(2) ,SU_6_1D(3),
+ SU_6_BD(4),SU_24_BD(5),BU_B14(6),
+ BU_B28(7) ,RB_B14(8) ,RB_B28(9),SU_BD(10),SU_54_BD(11),
+ SU_3_1D (12), SU_3_4D (13),
+ AUS_BS(14), AUS_SA(15),
+ AU_BS_4900(16), AU_SA_4900(17), SU_BD_4900(18),
+ BU_B100(19), RB_B100(20), SU_I(21),
+ AU_EZ(22),
+ setDefaults(100)
+ }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteWCU 13 }
+
+
+ brzLighteCountryCode OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "."
+ ::= { brzLighteWCU 14 }
+
+
+ brzLighteAntennaGain OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ " -1 stands for: do NOT transmit, -2 stands for: don't care."
+ ::= { brzLighteWCU 15 }
+
+brzLighteOemParams OBJECT IDENTIFIER ::= { brzLighteWCU 16 }
+
+ brzLighteFixOemType OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(32))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Get/Set OEM Type of Unit.
+ 1: Alvarion,
+ 4: Nera,
+ 6: Empty OEM Strings."
+ ::= { brzLighteOemParams 1 }
+
+ brzLighteOemProjectNameString OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(32))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Get/Set OEM Product Line of Unit.
+ The setting is only possible if the oem string is empty."
+ ::= { brzLighteOemParams 2 }
+
+ brzLighteOemManufactureNameString OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(32))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Get/Set OEM Vendor Name for Unit.
+ The setting is only possible if the oem string is empty."
+ ::= { brzLighteOemParams 3 }
+
+ brzLighteSetMibEnterprise OBJECT-TYPE
+ SYNTAX INTEGER { enterprise710 (710), enterprise8295 (8295) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "enterprise710 - breezecom, enterprise8295 - bwa.
+ will come into effect only after next reset. To use
+ this, the unit must be in technician mode. "
+ ::= { brzLighteOemParams 4 }
+
+
+ brzLighteAtherosRegTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BrzLighteAtherosRegEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. Atheros registers Table"
+ ::= {brzLighteningTest 11}
+
+ brzLighteAtherosRegEntry OBJECT-TYPE
+ SYNTAX BrzLighteAtherosRegEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ AN entry in the Atheros register table"
+ INDEX { brzLighteAtherosRegOffsetMask }
+ ::= { brzLighteAtherosRegTable 1 }
+
+ BrzLighteAtherosRegEntry ::= SEQUENCE {
+ brzLighteAtehrosRegValue INTEGER,
+ brzLighteAtherosRegOffsetMask INTEGER
+ }
+
+ brzLighteAtehrosRegValue OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ ""
+ ::= { brzLighteAtherosRegEntry 1 }
+
+ brzLighteAtherosRegOffsetMask OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ ""
+ ::= { brzLighteAtherosRegEntry 2 }
+
+ brzLighteAUSSubscribersNo OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Number of Subscribers that can be associated to AUS"
+ ::= { brzLighteWCU 17 }
+
+ brzLighteSUPMaxMirDownlink OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ Range for set: 128 to 53,888 (Kbps)
+ The actual value (Get) will be the entered value rounded to the nearest
+ multiple of 128 (N*128)."
+ ::= { brzLighteWCU 19 }
+
+ brzLighteBNB10MHzSupport OBJECT-TYPE
+ SYNTAX INTEGER { nonSupported(0), supported(1) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to BNB only"
+ ::= { brzLighteWCU 20 }
+
+
+ brzLighteModemUtilisation OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Modem Utilization value"
+ ::= { brzLighteningTest 12 }
+
+brzLighteANI OBJECT IDENTIFIER ::= { brzLighteningTest 13 }
+
+ brzLighteNoiseImmunityStateControl OBJECT-TYPE
+ SYNTAX INTEGER { Manual(0),Automatic(1) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Noise Immunity State Control"
+ ::= { brzLighteANI 1 }
+
+ brzLighteNoiseImmunityLevel OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Noise Immunity Level
+ Allowed range is 0 to 4"
+ ::= { brzLighteANI 2 }
+
+ brzLighteSpurImunityLevel OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Spur Imunity Level
+ Allowed range is 0 to 7"
+ ::= { brzLighteANI 3 }
+
+ brzLighteOFDMWeakSignal OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "OFDM Weak Signal
+ Allowed range is 0 to 1"
+ ::= { brzLighteANI 4 }
+
+ brzLightePulseDetectionSensitivity OBJECT-TYPE
+ SYNTAX INTEGER { Low(0),High(1) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Pulse Detection Sensitivity"
+ ::= { brzLighteANI 5 }
+
+brzLighteANIState OBJECT IDENTIFIER ::= { brzLighteningTest 14 }
+
+ brzLighte_noiseImmunityLevel OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "noiseImmunityLevel"
+ ::= { brzLighteANIState 1 }
+
+ brzLighte_spurImmunityLevel OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "spurImmunityLevel"
+ ::= { brzLighteANIState 2 }
+
+ brzLighte_ofdmWeakSigDetectionOff OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "ofdmWeakSigDetectionOff"
+ ::= { brzLighteANIState 3 }
+
+ brzLighte_cckWeakSigThresholdHigh OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "cckWeakSigThresholdHigh"
+ ::= { brzLighteANIState 4 }
+
+ brzLighte_firstepLevel OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "firstepLevel"
+ ::= { brzLighteANIState 5 }
+
+ brzLighte_spurImmunityBias OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "spurImmunityBias"
+ ::= { brzLighteANIState 6 }
+
+ brzLighte_phyErrStatsDisabled OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "phyErrStatsDisabled"
+ ::= { brzLighteANIState 7 }
+
+ brzLighteVLAteSetTestResults OBJECT-TYPE
+ SYNTAX INTEGER {none(0), pass(1), fail(2)}
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Set the Ate Test Results"
+ ::= { brzLighteGenParams 16 }
+
+ brzLighteVLSetSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..35))
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Set the Serial Number"
+ ::= { brzLighteGenParams 17 }
+END
diff --git a/mibs/alvarion/BWA-DOT11-WLAN-MIB b/mibs/alvarion/BWA-DOT11-WLAN-MIB
new file mode 100755
index 0000000000..3135e6c5e2
--- /dev/null
+++ b/mibs/alvarion/BWA-DOT11-WLAN-MIB
@@ -0,0 +1,6053 @@
+-- Title: BWA Private MIB
+-- This Private MIB supports BWA-PtMP and BWA-PtP product lines.
+--
+--
+-- Version: 4.5.16
+-- Date: Tuesday August 14 2007
+-- Comments: BWA agents also support the following Public MIBs:
+
+-- This MIB supports BWA VL products (AU and SU),
+-- BWA 4900 (AU and SU) and
+-- BWA-PtP products (BU and RB).
+
+-- Some MIB compilers require that the following lines
+-- for proper compilation
+
+--#include "rfc1155.smi"
+--#include "rfc1212.smi"
+
+
+-- mgmt OBJECT IDENTIFIER ::= { iso org(3) dod(6) internet(1) mgmt(2) }
+-- mib OBJECT IDENTIFIER ::= { mgmt 1 }
+-- directory OBJECT IDENTIFIER ::= { internet 1 }
+-- experimental OBJECT IDENTIFIER ::= { internet 3 }
+-- private OBJECT IDENTIFIER ::= { internet 4 }
+-- enterprises OBJECT IDENTIFIER ::= { private 1 }
+
+-- End of lines which might be needed to other MIB browsers
+-- for proper compilation
+
+
+BWA-DOT11-WLAN-MIB DEFINITIONS ::= BEGIN
+
+
+ IMPORTS
+ MODULE-IDENTITY, NOTIFICATION-TYPE, enterprises, IpAddress,Counter32,OBJECT-TYPE
+ FROM SNMPv2-SMI;
+
+bwa OBJECT IDENTIFIER ::= { enterprises 12394 }
+products OBJECT IDENTIFIER ::= { bwa 1 }
+
+bwaVLMib MODULE-IDENTITY
+ LAST-UPDATED "0708141146Z"
+ ORGANIZATION "BWA Products"
+ CONTACT-INFO "Contact Man
+ Postal: BWA Products
+ Street Number ZipCode
+ Country
+ Tel: 000-0-0000000
+ Fax: 000-0-0000000
+ E-mail: E-mail"
+ DESCRIPTION
+ "BWA VL products, BWA 4900, BWA-PtP"
+ REVISION "0708141146Z"
+ DESCRIPTION
+ "Version 4.5"
+ ::= { products 1 }
+
+
+ MacAddress ::= OCTET STRING (SIZE(6))
+ DisplayString ::= OCTET STRING
+
+bwaOID OBJECT IDENTIFIER ::= { bwa 4 }
+bwaVLOID OBJECT IDENTIFIER ::= { bwaOID 1 }
+
+
+bwaVLAU OBJECT IDENTIFIER ::= { bwaVLOID 1 }
+bwaVLSU OBJECT IDENTIFIER ::= { bwaVLOID 2 }
+
+bwaVLAU-BS OBJECT IDENTIFIER ::= { bwaVLOID 4 }
+bwaVLAU-SA OBJECT IDENTIFIER ::= { bwaVLOID 5 }
+
+bwaVLAUS-BS OBJECT IDENTIFIER ::= { bwaVLOID 6 }
+bwaVLAUS-SA OBJECT IDENTIFIER ::= { bwaVLOID 7 }
+bwaVLAU-EZ OBJECT IDENTIFIER ::= { bwaVLOID 8 }
+
+
+bwaVLSU-6-1D OBJECT IDENTIFIER ::= { bwaVLOID 11 }
+bwaVLSU-6-BD OBJECT IDENTIFIER ::= { bwaVLOID 12 }
+bwaVLSU-24-BD OBJECT IDENTIFIER ::= { bwaVLOID 13 }
+bwaVLSU-BD OBJECT IDENTIFIER ::= { bwaVLOID 14 }
+bwaVLSU-54-BD OBJECT IDENTIFIER ::= { bwaVLOID 15 }
+
+bwaVLSU-3-1D OBJECT IDENTIFIER ::= { bwaVLOID 16 }
+bwaVLSU-3-4D OBJECT IDENTIFIER ::= { bwaVLOID 17 }
+bwaVLSU-I OBJECT IDENTIFIER ::= { bwaVLOID 18 }
+
+
+ptp-BU-B14 OBJECT IDENTIFIER ::= { bwaVLOID 21 }
+ptp-BU-B28 OBJECT IDENTIFIER ::= { bwaVLOID 22 }
+ptp-BU-B100 OBJECT IDENTIFIER ::= { bwaVLOID 23 }
+
+ptp-RB-B14 OBJECT IDENTIFIER ::= { bwaVLOID 31 }
+ptp-RB-B28 OBJECT IDENTIFIER ::= { bwaVLOID 32 }
+ptp-RB-B100 OBJECT IDENTIFIER ::= { bwaVLOID 33 }
+
+bwa4900-AU-BS OBJECT IDENTIFIER ::= { bwaVLOID 41 }
+bwa4900-AU-SA OBJECT IDENTIFIER ::= { bwaVLOID 42 }
+bwa4900-SU-BD OBJECT IDENTIFIER ::= { bwaVLOID 51 }
+
+bwaVLProducts OBJECT IDENTIFIER ::= { bwaVLOID 3 }
+
+-- ****************************************************************************************
+-- ****************************************************************************************
+-- General System Info
+-- ===================
+bwaVLSysInfo OBJECT IDENTIFIER ::= {bwaVLMib 1}
+
+
+ bwaVLUnitHwVersion OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..32))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Hardware platform version."
+ ::= { bwaVLSysInfo 1 }
+
+ bwaVLRunningSoftwareVersion OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..32))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Running software version."
+ ::= { bwaVLSysInfo 2 }
+
+ bwaVLRunningFrom OBJECT-TYPE
+ SYNTAX INTEGER { mainVersion(1) , shadowVersion(2)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The memory (main or shadow) from which the current version is
+ running from."
+ ::= { bwaVLSysInfo 3 }
+
+ bwaVLMainVersionNumber OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..32))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Main software version number."
+ ::= { bwaVLSysInfo 4 }
+
+ bwaVLMainVersionFileName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..32))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Main software version file name."
+ ::= { bwaVLSysInfo 5 }
+
+
+ bwaVLShadowVersionNumber OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..32))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Shadow software version number."
+ ::= { bwaVLSysInfo 6 }
+
+ bwaVLShadowVersionFileName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..32))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Shadow software version file name."
+ ::= { bwaVLSysInfo 7 }
+
+ bwaVLUnitMacAddress OBJECT-TYPE
+ SYNTAX MacAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Unit hardware MAC address."
+ ::= { bwaVLSysInfo 8 }
+
+ bwaVLUnitType OBJECT-TYPE
+ SYNTAX INTEGER {auBS (1), auSA(2) , su-6-1D(3),su-6-BD(4),su-24-BD(5),
+ bu-B14(6),bu-B28(7),rb-B14(8),rb-B28(9),su-BD(10),su-54-BD (11),
+ su-3-1D(12),su-3-4D(13),ausBS(14),ausSA(15),
+ auBS4900(16),auSA4900(17),su4900(18), bu-B100(19), rb-B100(20), su-I(21),
+ au-E(22) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ auBS (1) : AU-BS (modular access unit).
+ auSA (2) : AU-SA (stand-alone access unit).
+ su-6-1D (3) : SU-6-1D (subscriber unit supporting 6 Mbps)
+ su-6-BD (4) : SU-6-BD (subscriber unit supporting 6 Mbps).
+ su-24-BD (5) : SU-24-BD (subscriber unit supporting 24 Mbps).
+ bu-B14 (6) : BU-B14 (PtP Base Unit supporting 14 Mbps).
+ bu-B28 (7) : BU-B28 (PtP Base Unit supporting 28 Mbps).
+ rb-B14 (8) : RB-B14 (PtP Remote Bridge supporting 14 Mbps).
+ rb-B28 (9) : RB-B28 (PtP Remote Bridge supporting 28 Mbps).
+ su-BD (10) : SU-BD (subscriber unit).
+ su-54-BD(11) : SU-54-BD (subscriber unit supporting 54 Mbps).
+ su-3-1D (12) : SU-3-1D (subscriber unit supporting 3 Mbps).
+ su-3-4D (13) : SU-3-4D (subscriber unit supporting 3 Mbps).
+ ausBS (14) : AUS-BS (modular access unit supporting maxim 8 or 25
+ (via licensing) subscribers and allowing association
+ only with SU-3 or SU-6).
+ ausSA (15) : AUS-SA (stand-alone access unit supporting maxim 8 or 25
+ (via licensing)subscribers and allowing association only
+ with SU-3 or SU-6 ).
+ auBS4900(16) : AU-BS-4900 (BWA 4900 modular access unit)
+ auSA4900(17) : AU-SA-4900 (BWA 4900 stand alone access unit)
+ suBD4900(18) : SU-BD-4900 (BWA 4900 subscriber unit)
+ bu-B100 (19) : BU-B100 (PtP Base Unit unlimited throughput)
+ rb-B100 (20) : BU-B100 (PtP Remote Bridge unlimited throughput)
+ su-I (21) : SU-I
+ au-E (22) : AU-E"
+ ::= { bwaVLSysInfo 9 }
+
+ bwaVLAssociatedAU OBJECT-TYPE
+ SYNTAX MacAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Associated AU/BU MAC address."
+ ::= { bwaVLSysInfo 10 }
+
+ bwaVLNumOfAssociationsSinceLastReset OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The number of associations since last reset, including
+ duplicate associations (re-associations)."
+ ::= { bwaVLSysInfo 11 }
+
+ bwaVLCurrentNumOfAssociations OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ Not applicable to BWA-PtP products.
+ The number of SUs currently associated with the AU.
+ BWA-PtP products return 65535."
+ ::= { bwaVLSysInfo 13 }
+
+ bwaVLUnitBootVersion OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..32))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Boot version."
+ ::= { bwaVLSysInfo 14 }
+
+ bwaVLRadioBand OBJECT-TYPE
+ SYNTAX INTEGER {band-5-8GHz (1), band-5-4GHz (2) , band-4-9GHz (3),band-5-2GHz (4),band-2-4GHz (5),band-5-3GHz (6),band-4-9GHzJapan (7)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The unit's radio band."
+ ::= { bwaVLSysInfo 15 }
+
+ bwaVLCurrentEthernetPortState OBJECT-TYPE
+ SYNTAX INTEGER { halfDuplexAnd10Mbps (1),
+ fullDuplexAnd10Mbps (2),
+ halfDuplexAnd100Mbps (3),
+ fullDuplexAnd100Mbps (4),
+ linkDown (5) }
+
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The current Ethernet port state."
+ ::= { bwaVLSysInfo 16 }
+
+
+
+ bwaVLTimeSinceLastReset OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..32))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The elapsed time since last reset."
+ ::= { bwaVLSysInfo 17 }
+
+bwaVLCountryDependentParameters OBJECT IDENTIFIER ::= {bwaVLSysInfo 18}
+
+ bwaVLCountryCode OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..32))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The country code and country name or country group name
+ that is supported by the unit."
+ ::= { bwaVLCountryDependentParameters 1 }
+
+ bwaVLCountryDependentParamsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BwaVLCountryDependentParameterEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. A table of country dependent parameters."
+ ::= {bwaVLCountryDependentParameters 2}
+
+ bwaVLCountryDependentParameterEntry OBJECT-TYPE
+ SYNTAX BwaVLCountryDependentParameterEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ An entry in the Country Dependent Parameters table."
+ INDEX { bwaVLCountryDependentParameterTableIdx }
+ ::= { bwaVLCountryDependentParamsTable 1 }
+
+ BwaVLCountryDependentParameterEntry ::= SEQUENCE {
+ bwaVLCountryDependentParameterTableIdx INTEGER,
+ bwaVLCountryDependentParameterFrequencies DisplayString,
+ bwaVLAllowedBandwidth INTEGER,
+ bwaVLRegulationMaxTxPowerAtAntennaPort INTEGER,
+ bwaVLRegulationMaxEIRP INTEGER,
+ bwaVLMinModulationLevel INTEGER,
+ bwaVLMaxModulationLevel INTEGER,
+ bwaVLBurstModeSupport INTEGER,
+ bwaVLMaximumBurstDuration INTEGER,
+ bwaVLDfsSupport INTEGER,
+ bwaVLMinimumHwRevision INTEGER
+ }
+
+ bwaVLCountryDependentParameterTableIdx OBJECT-TYPE
+ SYNTAX INTEGER (1..5)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The sub-band ID of the entry in the Country Dependent
+ Parameters table. Serves also as index for the table entry."
+ ::= { bwaVLCountryDependentParameterEntry 1 }
+
+ bwaVLCountryDependentParameterFrequencies OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The frequencies included in the applicable sub-band entry."
+ ::= { bwaVLCountryDependentParameterEntry 2 }
+
+ bwaVLAllowedBandwidth OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The bandwidth when using the applicable the sub-band."
+ ::= { bwaVLCountryDependentParameterEntry 3 }
+
+ bwaVLRegulationMaxTxPowerAtAntennaPort OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The maximum allowed Tx power when using the applicable sub-band.
+ A RegulationMaxTxPowerAtAntennaPort of 255, means no limit"
+ ::= { bwaVLCountryDependentParameterEntry 4 }
+
+ bwaVLRegulationMaxEIRP OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The maximum Tx EIRP
+ when using the applicable sub-band.
+ A Regulation Max EIRP of 0, means no limit."
+ ::= { bwaVLCountryDependentParameterEntry 5 }
+
+
+ bwaVLMinModulationLevel OBJECT-TYPE
+ SYNTAX INTEGER { level1 (1),
+ level2 (2),
+ level3 (3),
+ level4 (4),
+ level5 (5),
+ level6 (6),
+ level7 (7),
+ level8 (8)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The minimum supported modulation level."
+ ::= { bwaVLCountryDependentParameterEntry 6 }
+
+ bwaVLMaxModulationLevel OBJECT-TYPE
+ SYNTAX INTEGER { level1 (1),
+ level2 (2),
+ level3 (3),
+ level4 (4),
+ level5 (5),
+ level6 (6),
+ level7 (7),
+ level8 (8)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The maximum supported modulation level."
+ ::= { bwaVLCountryDependentParameterEntry 7 }
+
+ bwaVLBurstModeSupport OBJECT-TYPE
+ SYNTAX INTEGER {supported(1), notSupported(2)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The supported Burst Mode Option."
+ ::= { bwaVLCountryDependentParameterEntry 8}
+
+ bwaVLMaximumBurstDuration OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Applicable only if Burst Mode Option is supported.
+ The maximum supported burst duration."
+ ::= { bwaVLCountryDependentParameterEntry 9}
+
+
+ bwaVLDfsSupport OBJECT-TYPE
+ SYNTAX INTEGER {supported(1), notSupported(2)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ The supported Dfs Option."
+ ::= { bwaVLCountryDependentParameterEntry 10}
+
+ bwaVLMinimumHwRevision OBJECT-TYPE
+ SYNTAX INTEGER {hwRevisionA (1), hwRevisionB (2),
+ hwRevisionC (3), hwRevisionD (4),
+ hwRevisionE (5), na (255)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The Minimum HW Revision needed to support the country code."
+ ::= { bwaVLCountryDependentParameterEntry 11}
+
+
+ bwaVLAuthenticationEncryptionSupport OBJECT-TYPE
+ SYNTAX INTEGER {supported(1), notSupported(2)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The supported Authentication Encryption Option."
+ ::= { bwaVLCountryDependentParameters 3 }
+
+ bwaVLDataEncryptionSupport OBJECT-TYPE
+ SYNTAX INTEGER {supported(1), notSupported(2)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The supported Data Encryption Option."
+ ::= { bwaVLCountryDependentParameters 4 }
+
+ bwaVLAESEncryptionSupport OBJECT-TYPE
+ SYNTAX INTEGER {supported(1), notSupported(2)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The supported AES Encryption Option."
+ ::= { bwaVLCountryDependentParameters 5 }
+
+ bwaVLAntennaGainChange OBJECT-TYPE
+ SYNTAX INTEGER {supported(1), notSupported(2)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Indicates whether the Antenna Gain parameter is changeable or fixed."
+ ::= { bwaVLSysInfo 19 }
+
+ bwaVLAteTestResults OBJECT-TYPE
+ SYNTAX INTEGER { none(0), pass(1), fail(2) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Results of ATE Test "
+ ::= { bwaVLSysInfo 20 }
+
+ bwaVLSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..35))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Serial Number of the unit"
+ ::= { bwaVLSysInfo 21 }
+
+-- Unit Control
+-- ============
+bwaVLUnitControl OBJECT IDENTIFIER ::= {bwaVLMib 2}
+
+ bwaVLResetUnit OBJECT-TYPE
+ SYNTAX INTEGER { cancel (1), resetSystemNow (2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Resets the unit and applies new parameter values."
+ ::= { bwaVLUnitControl 1 }
+
+
+ bwaVLSetDefaults OBJECT-TYPE
+ SYNTAX INTEGER { noDefaultSettingRequested (0),
+ completeFactory (1),
+ partialFactory (2),
+ completeOperator (3),
+ partialOperator (4),
+ cancelCurrentPendingRequest(5) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Sets unit configuration to Defaults values after the
+ next reset.
+ noDefaultSettingRequested : Read-Only Option, no Default setting was Issued.
+ completeFactory : All parameters revert to Factory
+ Defaults values.
+ partialFactory : All parameters revert to Factory
+ Defaults values, except the parameters
+ required for maintaining wireless
+ connectivity.
+ completeOperator: All parameters revert to Operator
+ Defaults values.
+ partialOperator : All parameters revert to Operator
+ Defaults values, except the parameters
+ required for maintaining wireless
+ connectivity.
+ cancelCurrentPendingRequest : Default Setting request is cancelled."
+ ::= { bwaVLUnitControl 2 }
+
+ bwaVLUnitName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..32))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The unit name.
+ A string of up to 32 printable ASCII characters."
+ ::= { bwaVLUnitControl 3 }
+
+ bwaVLFlashMemoryControl OBJECT-TYPE
+ SYNTAX INTEGER { resetAndBootFromShadowVersion (1),
+ useRunningVersionAfterReset (2),cancel(3) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ resetAndBootFromShadowVersion : Activates the backup
+ version.
+ useRunningVersionAfterReset : The currently active
+ version will become the main
+ version and will be activated
+ after next reset."
+ ::= { bwaVLUnitControl 4 }
+
+
+ bwaVLTelnetLogoutTimer OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Time-out of management via Telnet program.
+ Automatic exit if the program is inactive for the
+ defined time.
+ Range: 1 to 999 (minutes)."
+ ::= { bwaVLUnitControl 5 }
+
+ bwaVLSaveCurrentConfigurationAsOperatorDefaults OBJECT-TYPE
+ SYNTAX INTEGER { saveAsDefaults (1),cancel(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Saves the current configuration as Operator Defaults.
+ Cannot be executed after requesting set defaults
+ and the unit was not reset."
+ ::= { bwaVLUnitControl 6 }
+
+ bwaVLExitTelnet OBJECT-TYPE
+ SYNTAX INTEGER { cancelOperation (1), exit (2)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Exit the management via Telnet program."
+ ::= { bwaVLUnitControl 7 }
+
+bwaVLUnitPasswords OBJECT IDENTIFIER ::= {bwaVLUnitControl 8}
+
+ bwaVLReadOnlyPassword OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(1..8))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The User (read only) password.
+ This is also the Read Community String.
+ Up to 8 printable ASCII characters."
+ ::= { bwaVLUnitPasswords 1 }
+
+ bwaVLInstallerPassword OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(1..8))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The Installer password.
+ Up to 8 printable ASCII characters."
+ ::= { bwaVLUnitPasswords 2 }
+
+ bwaVLAdminPassword OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(1..8))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The Administrator password. Accessible only with SNMP Write
+ Community String (administrator password).
+ Up to 8 printable ASCII characters."
+ ::= { bwaVLUnitPasswords 3 }
+
+
+ bwaVLEthernetNegotiationMode OBJECT-TYPE
+ SYNTAX INTEGER { force10MbpsAndHalfDuplex (1),
+ force10MbpsAndFullDuplex (2),
+ force100MbpsAndHalfDuplex (3),
+ force100MbpsAndFullDuplex (4),
+ autoNegotiationMode (5) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The speed/duplex mode of the Ethernet port."
+ ::= { bwaVLUnitControl 9 }
+
+bwaVLFTPParameters OBJECT IDENTIFIER ::= {bwaVLUnitControl 10}
+
+bwaVLFTPServerParams OBJECT IDENTIFIER ::= {bwaVLFTPParameters 1}
+
+ bwaVLFTPServerUserName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..18))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The user name to be used for access to the FTP server.
+ Accessible only with SNMP Write Community String
+ (administrator password)."
+ ::= { bwaVLFTPServerParams 1 }
+
+ bwaVLFTPServerPassword OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..18))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The password to be used for access to the FTP server.
+ Accessible only with SNMP Write Community String
+ (administrator password)."
+ ::= { bwaVLFTPServerParams 2 }
+
+ bwaVLFTPClientIPAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ For SW version higher than 4.0 this is read-only.
+ The IP address of the FTP stack in the unit."
+ ::= { bwaVLFTPServerParams 3 }
+
+ bwaVLFTPServerIpAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The IP address of the FTP server."
+ ::= { bwaVLFTPServerParams 4 }
+
+ bwaVLFTPClientMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The Mask of the FTP stack in the unit."
+ ::= { bwaVLFTPServerParams 5 }
+
+
+ bwaVLFTPGatewayIpAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The FTP Gateway address"
+ ::= { bwaVLFTPServerParams 6 }
+
+
+bwaVLFTPSwDownload OBJECT IDENTIFIER ::= {bwaVLFTPParameters 2}
+
+ bwaVLFTPSwFileName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(1..20))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The name of the SW file to be downloaded."
+ ::= { bwaVLFTPSwDownload 1 }
+
+ bwaVLFTPSwSourceDir OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..80))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The source directory of the required file in the FTP server.
+ Up to 80 printable ASCII characters.
+ Use dot (.) To clear field"
+ ::= { bwaVLFTPSwDownload 2 }
+
+ bwaVLFTPDownloadSwFile OBJECT-TYPE
+ SYNTAX INTEGER { downloadFile (1) , cancel (2)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Execution of the SW download operation"
+ ::= { bwaVLFTPSwDownload 3 }
+
+bwaVLConfigurationFileLoading OBJECT IDENTIFIER ::= {bwaVLFTPParameters 3}
+
+ bwaVLConfigurationFileName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(1..20))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The name of the configuration file to be downloaded/uploaded."
+ ::= { bwaVLConfigurationFileLoading 1 }
+
+ bwaVLOperatorDefaultsFileName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(1..20))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The name of the Operator Defaults file to be downloaded/uploaded"
+ ::= { bwaVLConfigurationFileLoading 2 }
+
+ bwaVLFTPConfigurationFileSourceDir OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..80))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The source directory of the required file in the FTP server.
+ Up to 80 printable ASCII characters.
+ Use dot (.) To clear field"
+ ::= { bwaVLConfigurationFileLoading 3 }
+
+ bwaVLExecuteFTPConfigurationFileLoading OBJECT-TYPE
+ SYNTAX INTEGER {executeFTPGetConfigurationFile (1), executeFTPPutConfigurationFile (2),
+ executeFTPGetOperatorDefaults (3) , executeFTPPutOperatorDefaults (4), cancel (5) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Execution of the file download/upload operation."
+ ::= { bwaVLConfigurationFileLoading 4 }
+
+
+
+bwaVLEventLogFileUploading OBJECT IDENTIFIER ::= {bwaVLFTPParameters 4}
+
+ bwaVLEventLogFileName OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(1..20))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The name of the Event Log file to be uploaded."
+ ::= { bwaVLEventLogFileUploading 1 }
+
+ bwaVLEventLogDestinationDir OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..80))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The destination directory of the event log file.
+ Up to 80 printable ASCII characters.
+ Use dot (.) To clear field."
+ ::= { bwaVLEventLogFileUploading 2 }
+
+ bwaVLUploadEventLogFile OBJECT-TYPE
+ SYNTAX INTEGER { uploadFile (1) , cancel (2)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Execution of the event log upload operation."
+ ::= { bwaVLEventLogFileUploading 3 }
+
+ bwaVLLoadingStatus OBJECT-TYPE
+ SYNTAX INTEGER {inProcess (1), successful (2), failed (3)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The status of the last loading operation."
+ ::= { bwaVLUnitControl 11 }
+
+bwaVLEventLogFileParams OBJECT IDENTIFIER ::= {bwaVLUnitControl 12}
+
+ bwaVLEventLogPolicy OBJECT-TYPE
+ SYNTAX INTEGER {message (1), warning (2), error (3),fatal(4), logNone(5)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The lowest level event to be registered in the event log."
+ ::= { bwaVLEventLogFileParams 1 }
+
+ bwaVLEraseEventLog OBJECT-TYPE
+ SYNTAX INTEGER { eraseEventLog (1),cancel(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Erase the event log."
+ ::= { bwaVLEventLogFileParams 2 }
+
+ bwaVLSystemLocation OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..34))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The unit location."
+ ::= { bwaVLUnitControl 13 }
+
+bwaVLFeatureUpgrade OBJECT IDENTIFIER ::= {bwaVLUnitControl 14}
+
+ bwaVLFeatureUpgradeManually OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(32..64))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Upgrade unit to support new feature. Enter your license number
+ (32 to 64 hex digits)."
+ ::= { bwaVLFeatureUpgrade 1 }
+
+bwaVLChangeUnitType OBJECT-TYPE
+ SYNTAX INTEGER { bu(1), rb(2), cancel(3) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable RB/BU only.
+ Change the unit type between BU and RB."
+ ::= { bwaVLUnitControl 15 }
+
+ bwaLighteAPWorkingMode OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ Change unit running mode: 0 - VL mode 1 - Mixed cell mode"
+ ::= { bwaVLUnitControl 16 }
+
+
+-- Network Management Params
+-- =========================
+ bwaVLNwMngParameters OBJECT IDENTIFIER ::= {bwaVLMib 3}
+
+ bwaVLAccessToNwMng OBJECT-TYPE
+ SYNTAX INTEGER { fromWirelessOnly (1),
+ fromEthernetOnly (2),
+ fromBothWirelessAndEthernet (3),
+ na (255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The port to be used for remote management."
+ ::= { bwaVLNwMngParameters 1 }
+
+
+ bwaVLNwMngFilter OBJECT-TYPE
+ SYNTAX INTEGER { disable (1),
+ activateOnEthernetPort (2),
+ activateOnWirelessPort (3),
+ activateOnBothWirelessAndEthernet (4),
+ na (255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Disables or enable on one of the ports, or on both
+ ports, IP address based filtering of management messages
+ (e.g. SNMP , Telnet , TFTP , DHCP)."
+ ::= { bwaVLNwMngParameters 2 }
+
+
+
+
+ mngIpFilterTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF MngIpFilterEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ A Management IP Filter Table of up to 3 IP addresses
+ of devices that are authorized to access the unit
+ for management purposes."
+ ::= { bwaVLNwMngParameters 3 }
+
+ mngIpFilterEntry OBJECT-TYPE
+ SYNTAX MngIpFilterEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ A Management IP Filter Table entry."
+ INDEX { bwaVLNwMngIpTableIdx }
+ ::= { mngIpFilterTable 1 }
+
+ MngIpFilterEntry ::= SEQUENCE { bwaVLNwMngIpAddress IpAddress,
+ bwaVLNwMngIpTableIdx INTEGER }
+
+ bwaVLNwMngIpAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ An IP address in the Management IP Filter Table."
+ ::= { mngIpFilterEntry 1 }
+
+ bwaVLNwMngIpTableIdx OBJECT-TYPE
+ SYNTAX INTEGER (1..10)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ A table index for an entry in the Management IP Filter
+ Table."
+ ::= { mngIpFilterEntry 2 }
+
+
+ bwaVLDeleteOneNwIpAddr OBJECT-TYPE
+ SYNTAX INTEGER (0 | 1..10 | 255)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ 0 - cancel operation.
+ 1..10 - Deletes a single selected entry from the Management IP
+ Filter Table."
+ ::= { bwaVLNwMngParameters 4 }
+
+ bwaVLDeleteAllNwIpAddrs OBJECT-TYPE
+ SYNTAX INTEGER { deleteAll (1), cancelOperation (2), na (255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Deletes all entries from the Management IP Filter Table."
+ ::= { bwaVLNwMngParameters 5 }
+
+ bwaVLAccessToNwTrap OBJECT-TYPE
+ SYNTAX INTEGER { disable(1), enable(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Enables or disables sending of traps."
+ ::= { bwaVLNwMngParameters 6 }
+
+ mngTrapTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF MngTrapEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ A Management Trap Table of up to 10 IP addresses of
+ stations to send traps to."
+ ::= { bwaVLNwMngParameters 7 }
+
+ mngTrapEntry OBJECT-TYPE
+ SYNTAX MngTrapEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ A Management Trap Table entry."
+ INDEX { bwaVLNwTrapTableIdx }
+ ::= { mngTrapTable 1 }
+
+ MngTrapEntry ::= SEQUENCE { bwaVLNwMngTrapCommunity DisplayString,
+ bwaVLNwMngTrapAddress IpAddress,
+ bwaVLNwTrapTableIdx INTEGER }
+
+ bwaVLNwMngTrapCommunity OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..14))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The trap community associated with the applicable
+ entry in the Management Trap Table.
+ Up to 14 printable case sensitive ASCII characters."
+ ::= { mngTrapEntry 1 }
+
+ bwaVLNwMngTrapAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ An IP address in the Management Trap Table entry."
+ ::= { mngTrapEntry 2 }
+
+ bwaVLNwTrapTableIdx OBJECT-TYPE
+ SYNTAX INTEGER (1..10)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Tables Index for an entry in the Management Trap Table."
+ ::= { mngTrapEntry 3 }
+
+
+ bwaVLDeleteOneTrapAddr OBJECT-TYPE
+ SYNTAX INTEGER (0 | 1..10 | 255)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ 0 - cancel operation.
+ 1..10 - Deletes a single selected entry from the Management
+ Trap Table."
+ ::= { bwaVLNwMngParameters 8 }
+
+
+ bwaVLDeleteAllTrapAddrs OBJECT-TYPE
+ SYNTAX INTEGER { deleteAll (1),cancelOperation (2), na (255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Deletes all entries from the Management Trap Table."
+ ::= { bwaVLNwMngParameters 9 }
+
+ bwaVLMngIpRangesTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BwaVLMngIpRangeEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Table of Management IP Address Ranges"
+ ::= { bwaVLNwMngParameters 10 }
+
+ bwaVLMngIpRangeEntry OBJECT-TYPE
+ SYNTAX BwaVLMngIpRangeEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ A Management IP Address Ranges Table entry"
+ INDEX { bwaVLMngIpRangeIdx }
+ ::= { bwaVLMngIpRangesTable 1 }
+
+ BwaVLMngIpRangeEntry ::= SEQUENCE {
+ bwaVLMngIpRangeIdx INTEGER,
+ bwaVLMngIpRangeFlag INTEGER,
+ bwaVLMngIpRangeStart IpAddress,
+ bwaVLMngIpRangeEnd IpAddress,
+ bwaVLMngIpRangeMask IpAddress
+ }
+
+
+ bwaVLMngIpRangeIdx OBJECT-TYPE
+ SYNTAX INTEGER (1..10)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Index of an entry in the Management IP Address Ranges Table"
+ ::= { bwaVLMngIpRangeEntry 1 }
+
+ bwaVLMngIpRangeFlag OBJECT-TYPE
+ SYNTAX INTEGER { rangeDefinedByStartEndAddr(1), rangeDefinedByStartAddrMask(2)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Defines the method of defining the range:
+ Using Start & End Address( rangeDefinedByStartEndAddr ),
+ or using Start Address and Mask ( rangeDefinedByStartAddrSubNetMask )."
+ ::= { bwaVLMngIpRangeEntry 2 }
+
+
+ bwaVLMngIpRangeStart OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Start Address of the range"
+ ::= { bwaVLMngIpRangeEntry 3 }
+
+ bwaVLMngIpRangeEnd OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ End Address of the range.
+ Used only if bwaVLMngIpRangeFlag is rangeDefinedByStartEndAddr"
+ ::= { bwaVLMngIpRangeEntry 4 }
+
+ bwaVLMngIpRangeMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ End Address of the range.
+ Used only if bwaVLMngIpRangeFlag is rangeDefinedByStartAddrMask"
+ ::= { bwaVLMngIpRangeEntry 5 }
+
+ bwaVLDeleteOneNwIpRange OBJECT-TYPE
+ SYNTAX INTEGER (0 | 1..10 | 255)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ 0 - cancel operation.
+ 1..10 - Deletes a single selected entry from the Management IP
+ Ranges Table."
+ ::= { bwaVLNwMngParameters 11 }
+
+
+ bwaVLDeleteAllNwIpRanges OBJECT-TYPE
+ SYNTAX INTEGER { deleteAll (1), cancelOperation (2), na (255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Deletes all entries from the Management IP Ranges Table."
+ ::= { bwaVLNwMngParameters 12 }
+
+ bwaVLApClientIpAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB unit only.
+ The IP Address of the WIFI WIMAX unit"
+ ::= { bwaVLNwMngParameters 13 }
+
+-- IP Params:
+-- ===========
+bwaVLIpParams OBJECT IDENTIFIER ::= {bwaVLMib 4}
+
+ bwaVLUnitIpAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ IP address of the unit."
+ ::= { bwaVLIpParams 1 }
+
+ bwaVLSubNetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Subnet mask of the unit."
+ ::= { bwaVLIpParams 2 }
+
+ bwaVLDefaultGWAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Default gateway IP address of the unit."
+ ::= { bwaVLIpParams 3 }
+
+ bwaVLUseDhcp OBJECT-TYPE
+ SYNTAX INTEGER{ disable (1),
+ dhcpOnly (2),
+ automatic (3) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ DHCP client mode of operation.
+ disabled : Use regular (manual) methods to configure IP
+ parameters.
+ dHCP Only: Use DHCP server to configure IP parameters.
+ automatic: Use DHCP server to configure IP parameters.
+ If a DHCP server is not available, use
+ manually configured values."
+ ::= { bwaVLIpParams 4 }
+
+ bwaVLAccessToDHCP OBJECT-TYPE
+ SYNTAX INTEGER{ fromWirelessOnly (1),
+ fromEthernetOnly (2),
+ fromBothWirelessAndEthernet (3) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The port to be used for communicating with a DHCP server."
+ ::= { bwaVLIpParams 5 }
+
+ bwaVLRunTimeIPaddr OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The run-time IP address. If DHCP is used the Run Time
+ IP Address is the address given to the unit by the
+ server. Otherwise it is the manually configured address."
+ ::= { bwaVLIpParams 6 }
+
+ bwaVLRunTimeSubNetMask OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The run-time Subnet Mask. If DHCP is used the Run Time
+ Subnet Mask is the mask given to the unit by the server.
+ Otherwise it is the manually configured mask."
+ ::= { bwaVLIpParams 7 }
+
+ bwaVLRunTimeDefaultIPGateway OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The run-time Gateway IP address. If DHCP is used the
+ Run Time Gateway IP Address is the address given to the
+ unit by the server. Otherwise it is the manually
+ configured address."
+ ::= { bwaVLIpParams 8 }
+
+
+-- Bridge Params
+-- ==============
+bwaVLBridgeParameters OBJECT IDENTIFIER ::= {bwaVLMib 5}
+
+
+bwaVLVLANSupport OBJECT IDENTIFIER ::= {bwaVLBridgeParameters 1}
+
+ bwaVLVlanID OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ VLAN ID for data frame tagging.
+ Applicable to Access Link only.
+ Range: 1 to 4094. 0 - not applicable."
+ ::= { bwaVLVLANSupport 1 }
+
+ bwaVLEthernetLinkType OBJECT-TYPE
+ SYNTAX INTEGER { accessLink (1),
+ trunkLink (2),
+ hybridLink (3),
+ serviceProviderLink (4) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ VLAN support mode (Link Type).
+ The Access Link option is not available for AU/BU.
+ Service Provider Link is not available for BU/RB."
+ ::= { bwaVLVLANSupport 2 }
+
+ bwaVLManagementVlanID OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ VLAN ID for management frame tagging.
+ Range: 1 to 4094, 65535 for No VLAN tagging."
+ ::= { bwaVLVLANSupport 3 }
+
+bwaVLVLANForwarding OBJECT IDENTIFIER ::= {bwaVLVLANSupport 4}
+
+ bwaVLVlanForwardingSupport OBJECT-TYPE
+ SYNTAX INTEGER { disable (1) , enable (2), na(255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Enables or disables the VLAN forwarding feature.
+ (applicable in Trunk and Service Provider links only)."
+ ::= { bwaVLVLANForwarding 1 }
+
+ bwaVLVlanForwardingTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BwaVLVlanForwardingEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ A VLAN Forwarding Table of up to 20 VLAN IDs of devices
+ to which data frames are forwarded when VLAN Forwarding
+ is Enabled. (applicable in Trunk and Service Provider links only)."
+ ::= { bwaVLVLANForwarding 2 }
+
+ bwaVLVlanForwardingEntry OBJECT-TYPE
+ SYNTAX BwaVLVlanForwardingEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ A VLAN Forwarding Table entry. (applicable in Trunk and Service Provider
+ links only)."
+ INDEX { bwaVLVlanForwardingTableIdx }
+ ::= { bwaVLVlanForwardingTable 1 }
+
+ BwaVLVlanForwardingEntry ::= SEQUENCE {
+ bwaVLVlanForwardingTableIdx INTEGER,
+ bwaVLVlanIdForwarding INTEGER
+ }
+
+
+ bwaVLVlanForwardingTableIdx OBJECT-TYPE
+ SYNTAX INTEGER (1..20)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ A read only table index for a VLAN entry in the VLAN
+ Forwarding Table."
+ ::= { bwaVLVlanForwardingEntry 1 }
+
+ bwaVLVlanIdForwarding OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The list of VLAN ID's in the VLAN ID Forwarding Table.
+ To Remove a VLAN ID - SET the corresponding entry to 0.
+ To Add a new VLAN ID SET an entry which is currently 0.
+ Range : 0 to 4094"
+ ::= { bwaVLVlanForwardingEntry 2 }
+
+bwaVLVlanRelaying OBJECT IDENTIFIER ::= {bwaVLVLANSupport 5}
+
+ bwaVLVlanRelayingSupport OBJECT-TYPE
+ SYNTAX INTEGER { disable (1) , enable (2), na(255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ Not applicable to BWA-PtP products.
+ Enables or disables VLAN Relaying (applicable in
+ Trunk and Service Provider links only)."
+ ::= { bwaVLVlanRelaying 1 }
+
+ bwaVLVlanRelayingTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BwaVLVlanRelayingEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ Not applicable to BWA-PtP products.
+ A VLAN Relaying Table of up to 20 VLAN IDs of devices
+ to which data frames are relayed when VLAN Relaying is
+ Enabled. (applicable in Trunk and Service Provider links only)."
+ ::= { bwaVLVlanRelaying 2 }
+
+ bwaVLVlanRelayingEntry OBJECT-TYPE
+ SYNTAX BwaVLVlanRelayingEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ Not applicable to BWA-PtP products.
+ A VLAN Relaying Table entry. (applicable in Trunk and Service
+ Provider links only)."
+ INDEX { bwaVLVlanRelayingTableIdx }
+ ::= { bwaVLVlanRelayingTable 1 }
+
+ BwaVLVlanRelayingEntry ::= SEQUENCE {
+ bwaVLVlanRelayingTableIdx INTEGER,
+ bwaVLVlanIdRelaying INTEGER
+ }
+
+ bwaVLVlanRelayingTableIdx OBJECT-TYPE
+ SYNTAX INTEGER (1..20)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ Not applicable to BWA-PtP products.
+ A table index for a VLAN entry in the VLAN
+ Relaying Table."
+ ::= { bwaVLVlanRelayingEntry 1 }
+
+
+ bwaVLVlanIdRelaying OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ Not applicable to BWA-PtP products.
+ The list of VLAN ID's in the VLAN ID Relaying Table.
+ To Remove a VLAN ID - SET the corresponding entry to 0.
+ To Add a new VLAN ID SET an entry which is currently 0.
+ Range: 0 to 4094 , 0 - remove entry."
+ ::= { bwaVLVlanRelayingEntry 2 }
+
+
+bwaVLVLANTrafficPriority OBJECT IDENTIFIER ::= {bwaVLVLANSupport 6}
+
+ bwaVLVlanDataPriority OBJECT-TYPE
+ SYNTAX INTEGER { na(255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Priority tagging for data frames. Applicable to Access
+ Link only.
+ Range: 0 to 7."
+ ::= { bwaVLVLANTrafficPriority 1 }
+
+ bwaVLVlanManagementPriority OBJECT-TYPE
+ SYNTAX INTEGER { na(255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Priority tagging for management frames. Applicable to
+ Access Link and Trunk Link only.
+ Range: 0 to 7."
+ ::= { bwaVLVLANTrafficPriority 2 }
+
+
+ bwaVLVlanPriorityThreshold OBJECT-TYPE
+ SYNTAX INTEGER { na(255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. Not applicable to units with SW
+ version 3.1 or higher.
+ Priority threshold for tagged frames received from
+ Ethernet port. Applicable to Hybrid Link and Trunk Link
+ only.
+ Valid values: 0-7."
+ ::= { bwaVLVLANTrafficPriority 3 }
+
+ bwaVLVLANQinQ OBJECT IDENTIFIER ::= {bwaVLVLANSupport 7}
+
+ bwaVLQinQEthertype OBJECT-TYPE
+ SYNTAX INTEGER (33025 .. 36864|37120|37376)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU and SU. Not applicable to PtP units.
+ The Ethernet type of the Service Provider Tag.
+ The range is 0x8101(33025) - 0x9000(36864), 0x9100(37120), 0x9200(37376)."
+ ::= { bwaVLVLANQinQ 1 }
+
+ bwaVLQinQProviderVlanID OBJECT-TYPE
+ SYNTAX INTEGER (1..4094)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU only.
+ VLAN ID of the Service Provider Tag."
+ ::= { bwaVLVLANQinQ 2 }
+
+ bwaVLBridgeAgingTime OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Bridge aging time for devices on both the Ethernet and
+ wireless link sides.
+ Range: 20 to 2000 seconds."
+ ::= { bwaVLBridgeParameters 2 }
+
+ bwaVLBroadcastRelaying OBJECT-TYPE
+ SYNTAX INTEGER { disable (1),
+ broadcastMulticastEnable (2),
+ broadcastEnable (3),
+ multicastEnable (4),
+ na (255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ Not applicable to BWA-PtP products.
+ Enables/disables the relaying of broadcast messages to
+ the wireless link."
+ ::= { bwaVLBridgeParameters 4 }
+
+ bwaVLUnicastRelaying OBJECT-TYPE
+ SYNTAX INTEGER { disable(1), enable(2), na (255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ Not applicable to BWA-PtP products.
+ Enables/disables the relaying of unicast messages to
+ the wireless link."
+ ::= { bwaVLBridgeParameters 5 }
+
+ bwaVLEthBroadcastFiltering OBJECT-TYPE
+ SYNTAX INTEGER { disable (1),
+ onEthernetOnly (2),
+ onWirelessOnly (3),
+ onBothWirelessAndEthernet (4),
+ na (255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Enables/disables the filtering of Ethernet (layer2)
+ broadcasts.
+ disable : No filtering.
+ onEthernetOnly : Filters broadcasts received on the Ethernet port only.
+ onWirelessOnly : Filters broadcasts received on the Wlan port only.
+ onBothWirelessAndEth: Filters broadcasts received on both ports."
+ ::= { bwaVLBridgeParameters 6 }
+
+bwaVLEthBroadcastingParameters OBJECT IDENTIFIER ::= {bwaVLBridgeParameters 7}
+
+ bwaVLDHCPBroadcastOverrideFilter OBJECT-TYPE
+ SYNTAX INTEGER { disable (1), enable (2), na (255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Enables or disables the broadcasting of DHCP messages,
+ overriding the general *bwaVLEthBroadcastFiltering Ethernet
+ broadcast filtering option."
+ ::= { bwaVLEthBroadcastingParameters 1 }
+
+ bwaVLPPPoEBroadcastOverrideFilter OBJECT-TYPE
+ SYNTAX INTEGER { disable (1), enable (2), na (255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Enables or disables the broadcasting of PPPoE messages,
+ overriding the general *bwaVLEthBroadcastFiltering Ethernet
+ broadcast filtering option."
+ ::= { bwaVLEthBroadcastingParameters 2 }
+
+ bwaVLARPBroadcastOverrideFilter OBJECT-TYPE
+ SYNTAX INTEGER { disable (1), enable (2), na (255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Enables or disables the broadcasting of ARP messages,
+ overriding the general *bwaVLEthBroadcastFiltering Ethernet
+ broadcast filtering option."
+ ::= { bwaVLEthBroadcastingParameters 3 }
+
+ bwaVLEthBroadcastMulticastLimiterOption OBJECT-TYPE
+ SYNTAX INTEGER { disable (1),
+ limitOnlyBroadcasts(2),
+ limitMulticastsExceptBroadcasts(3),
+ limitAllMulticasts(4) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Enable/disable the limiter for multicast and broadcast packets."
+ ::= { bwaVLEthBroadcastingParameters 4 }
+
+ bwaVLEthBroadcastMulticastLimiterThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The limit on the number of multicast and broadcast packets when the
+ Ethernet Broadcast/Multicast Limiter Option is enabled.
+ Range: 0 to 204800"
+ ::= { bwaVLEthBroadcastingParameters 5 }
+
+ bwaVLEthBroadcastMulticastLimiterSendTrapInterval OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The minimum time between two successive traps that are sent indicating the
+ number of packets that were dropped by the Ethernet Broadcast/Multicast
+ Limiter since the last trap was sent.
+ Range: 1 to 60 minutes"
+ ::= { bwaVLEthBroadcastingParameters 6 }
+
+bwaVLToSPriorityParameters OBJECT IDENTIFIER ::= {bwaVLBridgeParameters 8}
+
+ bwaVLToSPrecedenceThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. Not applicable to units with SW version 3.1 or higher.
+ Priority threshold (based on the ToS) for frames received
+ from the Ethernet port.
+ Range: 0 to 7."
+ ::= { bwaVLToSPriorityParameters 1 }
+
+ bwaVLRoamingOption OBJECT-TYPE
+ SYNTAX INTEGER { disable (1), enable (2), na(255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Disable/enable the roaming feature. When enabled, the SU/RB will start
+ scanning for an AU/BU after about one second of not receiving beacons or data
+ from current AU/BU. Once it found a new AU/BU, it will also send through
+ the wireless network a roaming SNAP on behalf of its clients informing
+ other devices in the network of their new location. When disabled, it
+ will wait for about seven seconds before starting scanning, and it will not
+ send a roaming SNAP."
+ ::= { bwaVLBridgeParameters 9 }
+
+bwaVLMacAddressDenyList OBJECT IDENTIFIER ::= {bwaVLBridgeParameters 10}
+
+ bwaVLMacAddressDenyListTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BwaVLMacAddressDenyListEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ Not applicable to BWA-PtP units.
+ A list of up to 100 MAC Addresses of SUs.
+ If bwaVLMacAddressDenyListAction is set to denyList,
+ these are SUs that are not allowed to transfer data
+ to the AU.
+ If bwaVLMacAddressDenyListAction is set to allowList,
+ only these SUs are allowed to transfer data to the AU."
+ ::= { bwaVLMacAddressDenyList 1 }
+
+ bwaVLMacAddressDenyListEntry OBJECT-TYPE
+ SYNTAX BwaVLMacAddressDenyListEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ Not applicable to BWA-PtP units.
+ An entry in the Mac Address Deny List Table."
+ INDEX { bwaVLMacAddressDenyListTableIdx }
+ ::= { bwaVLMacAddressDenyListTable 1 }
+
+ BwaVLMacAddressDenyListEntry ::= SEQUENCE {
+ bwaVLMacAddressDenyListTableIdx INTEGER,
+ bwaVLMacAddressDenyListId MacAddress
+ }
+
+ bwaVLMacAddressDenyListTableIdx OBJECT-TYPE
+ SYNTAX INTEGER (1..100)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ Not applicable to BWA-PtP units.
+ A read only table index for a MAC Address entry
+ in the Mac Address Deny List Table. Range: 1 to 100."
+ ::= { bwaVLMacAddressDenyListEntry 1 }
+
+ bwaVLMacAddressDenyListId OBJECT-TYPE
+ SYNTAX MacAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ Not applicable to BWA-PtP units.
+ The list of MAC Addresses in the Mac Address Deny
+ List Table.
+ To Remove a MAC Address - SET the corresponding entry
+ to 0.
+ To Add a new MAC Address - SET an entry which is
+ currently 0."
+ ::= { bwaVLMacAddressDenyListEntry 2 }
+
+ bwaVLMacAddressDenyListAdd OBJECT-TYPE
+ SYNTAX MacAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ Not applicable to BWA-PtP units.
+ Add a MAC address to the MAC Address Deny List Table"
+ ::= { bwaVLMacAddressDenyList 2 }
+
+ bwaVLMacAddressDenyListRemove OBJECT-TYPE
+ SYNTAX MacAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ Not applicable to BWA-PtP units.
+ Delete a MAC address from the MAC Address Deny List Table"
+ ::= { bwaVLMacAddressDenyList 3 }
+
+ bwaVLNumberOfMacAddressesInDenyList OBJECT-TYPE
+ SYNTAX INTEGER { na(255) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ Not applicable to BWA-PtP units.
+ Number of MAC addresses in the MAC Address Deny List Table."
+ ::= { bwaVLMacAddressDenyList 4 }
+
+bwaVLMacAddressDenyListAction OBJECT-TYPE
+ SYNTAX INTEGER { denyList(1), allowedList(2), na(255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ Define the action to be used by the Mac Address Deny List.
+ allowedList(2) means that the list becomes Allow list."
+ ::= { bwaVLMacAddressDenyList 5 }
+
+
+bwaVLPortsControl OBJECT IDENTIFIER ::= {bwaVLBridgeParameters 11}
+
+ bwaVLEthernetPortControl OBJECT-TYPE
+ SYNTAX INTEGER { disable(1), enable(2), na(255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Enable/disable the Ethernet port. When disabled, only
+ data frames are blocked. Management frames are accepted."
+ ::= { bwaVLPortsControl 1 }
+
+
+-- Air Interface Params
+-- =====================
+bwaVLAirInterface OBJECT IDENTIFIER ::= {bwaVLMib 6}
+
+bwaVLESSIDParameters OBJECT IDENTIFIER ::= {bwaVLAirInterface 1}
+
+ bwaVLESSID OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..31))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The Extended Service Set ID (ESSID) used to prevent
+ the merging of collocated systems.
+ The ESSID is accessible only with the write community
+ string (administrator password).
+ Up to 31 printable case sensitive ASCII characters."
+ ::= { bwaVLESSIDParameters 1 }
+
+
+ bwaVLOperatorESSIDOption OBJECT-TYPE
+ SYNTAX INTEGER {disable (1) , enable (2), na (255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Enabling/disabling the use of the Operator ESSID."
+ ::= { bwaVLESSIDParameters 2 }
+
+
+ bwaVLOperatorESSID OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..31))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ A secondary ESSID to support easy installation of SUs as well as
+ the use of the Best AU/BU feature.
+ Accessible only with SNMP Write Community
+ Up to 31 printable case sensitive ASCII characters."
+ ::= { bwaVLESSIDParameters 3}
+
+ bwaVLRunTimeESSID OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(31))
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ The ESSID of the associated AU/BU.
+ Accessible only with SNMP Write Community.
+ Up to 31 printable ASCII characters, case sensitive."
+ ::= { bwaVLESSIDParameters 4 }
+
+
+ bwaVLMaximumCellRadius OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ For AU/BU: read-write. In units with SW version 2.0 and up -
+ applicable only when the Cell Distance Mode is set to Manual.
+ The highest distance from the AU/BU of any SU/RB served by it.
+ Affects the maximum time the units wait for a response message
+ and the slot size by taking into account the round trip propagation delay.
+ For SU/RB: read-only. The distance is learned from the AU/BU.
+ Range: For units below version 2.0 the range is 0 - 50000 Meters.
+ Otherwise - the range is 0 to 54 Kilometers.
+ 0 means no compensation (minimum slot size, maximal delay timeout)."
+ ::= { bwaVLAirInterface 2 }
+
+ bwaVLAIFS OBJECT-TYPE
+ SYNTAX INTEGER { oneSlot (1), twoSlots (2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU and SU. Not applicable to BWA-PtP products.
+ Not applicable if Wireless Link Prioritization is enabled.
+ Arbitration Inter-Frame Spacing (AIFS) value, in slots.
+ This is the number of time slots that define the DIFS. (DIFS=SIFS+AIFS).
+ A value of 1 should be used only in point-to-point applications to
+ allow one unit to have advantage over the other unit."
+ ::= { bwaVLAirInterface 3 }
+
+
+ bwaVLWirelessTrapThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ A wireless link quality threshold, expressed in % of retransmissions,
+ for sending the bwaVLAUWirelessQualityTRAP.
+ This trap indicate whether the quality has gone below or
+ above the specified threshold.
+ The Threshold Range: 1 to 100 (% retransmissions)."
+ ::= { bwaVLAirInterface 4 }
+
+
+
+ bwaVLTransmitPowerTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BwaVLTransmitPowerEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ A table of transmit power parameters. "
+ ::= { bwaVLAirInterface 5}
+
+ bwaVLTransmitPowerEntry OBJECT-TYPE
+ SYNTAX BwaVLTransmitPowerEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ An entry in the Transmit Power Table."
+ INDEX { bwaVLTransmitPowerIdx }
+ ::= { bwaVLTransmitPowerTable 1 }
+
+ BwaVLTransmitPowerEntry ::= SEQUENCE { bwaVLTransmitPowerIdx INTEGER,
+ bwaVLApplicableModulationLevel INTEGER,
+ bwaVLMaximumTxPowerRange DisplayString,
+ bwaVLTxPower DisplayString,
+ bwaVLCurrentTxPower DisplayString
+ }
+
+ bwaVLTransmitPowerIdx OBJECT-TYPE
+ SYNTAX INTEGER (1..4)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ An index of an entry in the Transmit Power Table."
+ ::= { bwaVLTransmitPowerEntry 1 }
+
+
+ bwaVLApplicableModulationLevel OBJECT-TYPE
+ SYNTAX INTEGER {level1to5 (1), level6 (2), level7 (3),level8 (4)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The applicable modulation level for an entry in the Transmit Power Table.
+ Level 8 is not applicable to units with HW revision A."
+ ::= { bwaVLTransmitPowerEntry 2 }
+
+ bwaVLMaximumTxPowerRange OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The allowed range for the bwaVLTxPower parameter at the
+ applicable modulation level . Range: -10 to the maximum allowed
+ power level at the applicable modulation level , in dBm."
+ ::= { bwaVLTransmitPowerEntry 3 }
+
+
+ bwaVLTxPower OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Read-only for units with SW version 4.0 and higher.
+ In AU/BU: The transmit power in dBm defined for the applicable rate.
+ In SU/RB: If ATPC is disabled, this is the transmit power in dBm
+ defined for the applicable rate.
+ If ATPC is enabled, it serves as the initial transmit power in dBm
+ for the ATPC algorithm.
+ In SU/RB: The range is -10 dBm to the power value defined by
+ bwaVLMaximumTxPower for the applicable modulation level.
+ In AU/BU: The range is -10 dBm to the power value defined by
+ bwaVLMaximumTxPowerRange for the applicable modulation level."
+ ::= { bwaVLTransmitPowerEntry 4 }
+
+
+
+ bwaVLCurrentTxPower OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB.
+ The actual transmit power in dBm for the applicable rate.
+ Range: -17 to the maximum value defined by bwaVLMaximumTxPowerRange
+ for the applicable modulation level."
+ ::= { bwaVLTransmitPowerEntry 5 }
+
+ bwaVLMaximumTransmitPowerTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BwaVLMaximumTransmitPowerEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ A table of maximum transmit power parameters. "
+ ::= { bwaVLAirInterface 6}
+
+ bwaVLMaximumTransmitPowerEntry OBJECT-TYPE
+ SYNTAX BwaVLMaximumTransmitPowerEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ An entry in the Maximum Transmit Power Table."
+ INDEX { bwaVLMaximumTransmitPowerIdx }
+ ::= { bwaVLMaximumTransmitPowerTable 1 }
+
+ BwaVLMaximumTransmitPowerEntry ::= SEQUENCE { bwaVLMaximumTransmitPowerIdx INTEGER,
+ bwaVLMaxTxApplicableModulationLevel INTEGER,
+ bwaVLDefinedMaximumTxPowerRange DisplayString,
+ bwaVLMaxTxPower DisplayString
+ }
+
+ bwaVLMaximumTransmitPowerIdx OBJECT-TYPE
+ SYNTAX INTEGER (1..4)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ An index of an entry in the Maximum Transmit Power Table."
+ ::= { bwaVLMaximumTransmitPowerEntry 1 }
+
+
+ bwaVLMaxTxApplicableModulationLevel OBJECT-TYPE
+ SYNTAX INTEGER {level1to5 (1), level6 (2), level7 (3),level8 (4)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ The applicable modulation level for an entry in the Maximum
+ Transmit Power Table.
+ Level 8 is not applicable to units with HW revision A."
+ ::= { bwaVLMaximumTransmitPowerEntry 2 }
+
+ bwaVLDefinedMaximumTxPowerRange OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ The allowed range for the bwaVLMaxTxPower parameter at the
+ applicable modulation level .
+ Range: -10 to the maximum allowed power level at the applicable
+ modulation level , in dBm."
+ ::= { bwaVLMaximumTransmitPowerEntry 3 }
+
+
+ bwaVLMaxTxPower OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Read-only for units with SW version 4.0 and higher.
+ The maximum value that can be configured for the bwaVLTxPower
+ parameter. This is also the maximum power level that can be reached
+ by the ATPC algorithm.
+ The range is -10 dBm to the maximum value defined by
+ bwaVLDefinedMaximumTxPowerRange for the applicable modulation level."
+ ::= { bwaVLMaximumTransmitPowerEntry 4 }
+
+ bwaVLMaxNumOfAssociations OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ Not applicable to BWA-PtP products.
+ Sets the upper limit for the number of SUs
+ that can be associated with the AU.
+ Range: For regular AUs (AU-BS, AU-SA)
+ the range is from 0 to 512 if encryption is disabled
+ the range id form 0 to 124 if encryption is enabled
+ For AUS-BS and AUS-SA with SW version 4.0 and higher
+ the range is between 0 to 8 or 25 (via licensing).
+ For AUS-BS and AUS-SA with SW version below 4.0 the range
+ is between 0 to 5.
+ BWA-PtP products return 65535."
+ ::= { bwaVLAirInterface 10 }
+
+
+bwaVLBestAu OBJECT IDENTIFIER ::= {bwaVLAirInterface 11}
+
+ bwaVLBestAuSupport OBJECT-TYPE
+ SYNTAX INTEGER { disable (1), enable (2), na (255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Disable/enable the Best AU/BU selection mechanism."
+ ::= { bwaVLBestAu 1 }
+
+ bwaVLBestAuNoOfScanningAttempts OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ The number of scanning attempts to collect information
+ for the Best AU/BU decision.
+ Range: 1 to 255."
+ ::= { bwaVLBestAu 2 }
+
+ bwaVLPreferredAuMacAddress OBJECT-TYPE
+ SYNTAX MacAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ The MAC address of the preferred AU/BU (overriding the
+ Best AU/BU selection process).
+ 000000000000 means no preferred AU/BU."
+ ::= { bwaVLBestAu 3 }
+
+ bwaVLNeighborAuTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BwaVLNeighborAuEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ A table of data on neighboring AUs/BUs."
+ ::= { bwaVLBestAu 4}
+
+ bwaVLNeighborAuEntry OBJECT-TYPE
+ SYNTAX BwaVLNeighborAuEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ An entry in the Neighbor AU/BU Table."
+ INDEX { bwaVLNeighborAuIdx }
+ ::= { bwaVLNeighborAuTable 1 }
+
+ BwaVLNeighborAuEntry ::= SEQUENCE { bwaVLNeighborAuIdx INTEGER,
+ bwaVLNeighborAuMacAdd MacAddress,
+ bwaVLNeighborAuESSID DisplayString,
+ bwaVLNeighborAuSNR INTEGER,
+ bwaVLNeighborAuAssocLoadStatus INTEGER,
+ bwaVLNeighborAuMark INTEGER,
+ bwaVLNeighborAuHwRevision INTEGER,
+ bwaVLNeighborAuCountryCode INTEGER,
+ bwaVLNeighborAuSwVer DisplayString,
+ bwaVLNeighborAuAtpcOption INTEGER,
+ bwaVLNeighborAuAdapModOption INTEGER,
+ bwaVLNeighborAuBurstModeOption INTEGER,
+ bwaVLNeighborAuDfsOption INTEGER,
+ bwaVLNeighborAuConcatenationOption INTEGER,
+ bwaVLNeighborAuLearnCountryCodeBySU INTEGER,
+ bwaVLNeighborAuSecurityMode INTEGER,
+ bwaVLNeighborAuAuthOption INTEGER,
+ bwaVLNeighborAuDataEncyptOption INTEGER,
+ bwaVLNeighborAuPerSuDistanceLearning INTEGER
+ }
+
+ bwaVLNeighborAuIdx OBJECT-TYPE
+ SYNTAX INTEGER (1..20)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ An index of an entry in the Neighbor AU/BU Table."
+ ::= { bwaVLNeighborAuEntry 1 }
+
+ bwaVLNeighborAuMacAdd OBJECT-TYPE
+ SYNTAX MacAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ A MAC address of an AU/BU in the Neighbor AU/BU Table."
+ ::= { bwaVLNeighborAuEntry 2 }
+
+ bwaVLNeighborAuESSID OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ The ESSID of an AU/BU in the Neighbor AU/BU Table.
+ Accessible only with SNMP Write Community."
+ ::= { bwaVLNeighborAuEntry 3 }
+
+ bwaVLNeighborAuSNR OBJECT-TYPE
+ SYNTAX INTEGER { na (255) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ The received signal quality (SNR) in dB of an AU/BU
+ in the Neighbor AU/BU Table."
+ ::= { bwaVLNeighborAuEntry 4 }
+
+ bwaVLNeighborAuAssocLoadStatus OBJECT-TYPE
+ SYNTAX INTEGER { full (1),notFull (2), na (255) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Neighbor AU/BU association load status in the Neighbor
+ AU/BU Table."
+ ::= { bwaVLNeighborAuEntry 5 }
+
+ bwaVLNeighborAuMark OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Neighbor AU/BU mark in the Neighbor AU/BU Table."
+ ::= { bwaVLNeighborAuEntry 6 }
+
+ bwaVLNeighborAuHwRevision OBJECT-TYPE
+ SYNTAX INTEGER {hwRevisionA (1), hwRevisionB (2), hwRevisionC (3),
+ hwRevisionD (4), hwRevisionE (5),na (255)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Neighbor AU/BU HW revision in the Neighbor AU/BU Table."
+ ::= { bwaVLNeighborAuEntry 7 }
+
+ bwaVLNeighborAuCountryCode OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Neighbor AU/BU supported country code in the Neighbor
+ AU/BU Table."
+ ::= { bwaVLNeighborAuEntry 8 }
+
+ bwaVLNeighborAuSwVer OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Neighbor AU/BU SW version in the Neighbor
+ AU/BU Table."
+ ::= { bwaVLNeighborAuEntry 9 }
+
+ bwaVLNeighborAuAtpcOption OBJECT-TYPE
+ SYNTAX INTEGER { disable (1), enable (2), na (255)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Neighbor AU/BU ATPC option configuration in the Neighbor
+ AU/BU Table."
+ ::= { bwaVLNeighborAuEntry 10 }
+
+ bwaVLNeighborAuAdapModOption OBJECT-TYPE
+ SYNTAX INTEGER { disable (1), enable (2), na (255)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Neighbor AU/BU adaptive modulation option configuration
+ in the Neighbor AU/BU Table."
+ ::= { bwaVLNeighborAuEntry 11 }
+
+ bwaVLNeighborAuBurstModeOption OBJECT-TYPE
+ SYNTAX INTEGER { disable (1), enable (2), na (255)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Neighbor AU/BU burst mode option configuration
+ in the Neighbor AU/BU Table."
+ ::= { bwaVLNeighborAuEntry 12 }
+
+ bwaVLNeighborAuDfsOption OBJECT-TYPE
+ SYNTAX INTEGER { disable (1), enable (2), na(255)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Neighbor AU/BU DFS option configuration
+ in the Neighbor AU/BU Table."
+ ::= { bwaVLNeighborAuEntry 14 }
+
+ bwaVLNeighborAuConcatenationOption OBJECT-TYPE
+ SYNTAX INTEGER { disable (1), enable (2), na (255)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Neighbor AU/BU concatenation option configuration
+ in the Neighbor AU/BU Table."
+ ::= { bwaVLNeighborAuEntry 15 }
+
+ bwaVLNeighborAuLearnCountryCodeBySU OBJECT-TYPE
+ SYNTAX INTEGER { disable (1), enable (2), na (255)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU only.
+ Starting with 4.0 is not applicable for BWA 4900 and BWA PtP products.
+ Neighbor AU Learn Country Code by SU configuration
+ in the Neighbor AU Table."
+ ::= { bwaVLNeighborAuEntry 17 }
+
+ bwaVLNeighborAuSecurityMode OBJECT-TYPE
+ SYNTAX INTEGER {wep(1), aesOCB(2), fips197(3), na(255)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Neighbor AU/BU security mode configuration
+ in the Neighbor AU/BU Table."
+ ::= { bwaVLNeighborAuEntry 18 }
+
+ bwaVLNeighborAuAuthOption OBJECT-TYPE
+ SYNTAX INTEGER {openSystem (1), sharedKey (2), na (255)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Neighbor AU/BU authentication option configuration
+ in the Neighbor AU/BU Table."
+ ::= { bwaVLNeighborAuEntry 19 }
+
+ bwaVLNeighborAuDataEncyptOption OBJECT-TYPE
+ SYNTAX INTEGER {disable (1), enable (2), na (255)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Neighbor AU/BU data encryption option configuration
+ in the Neighbor AU/BU Table."
+ ::= { bwaVLNeighborAuEntry 20 }
+
+ bwaVLNeighborAuPerSuDistanceLearning OBJECT-TYPE
+ SYNTAX INTEGER {disable (1), enable (2), na (255)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU only.
+ Neighbor AU per SU distance learning option configuration
+ in the Neighbor AU Table."
+ ::= { bwaVLNeighborAuEntry 21 }
+
+bwaVLFrequencyDefinition OBJECT IDENTIFIER ::= {bwaVLAirInterface 12}
+
+
+ bwaVLSubBandLowerFrequency OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS obsolete
+ DESCRIPTION
+ "Applicable to SU only.
+ Not applicable to units with SW version 2.0 or higher.
+ The lowest frequency in the subset to be used for scanning.
+ For 5.8GHz products the range is 5740 to 5830 MHz using 10MHz resolution.
+ For 4.9GHz products the range is 4920 to 5080 MHz using 10MHz resolution.
+ For HW Revision C and above this leaf is not relevant - shall return 0."
+ ::= { bwaVLFrequencyDefinition 1 }
+
+ bwaVLSubBandUpperFrequency OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS obsolete
+ DESCRIPTION
+ "Applicable to SU only.
+ Not applicable to units with SW version 2.0 or higher.
+ The highest frequency in the subset to be used for scanning.
+ For 5.8GHz products the range is 5740 to 5830 MHz using 10MHz resolution.
+ For 4.9GHz products the range is 4920 to 5080 MHz using 10MHz resolution.
+ For HW Revision C and above this leaf is not relevant - shall return 0."
+ ::= { bwaVLFrequencyDefinition 2 }
+
+ bwaVLScanningStep OBJECT-TYPE
+ SYNTAX INTEGER { mhz-5(1), mhz-10(2) , mhz-20(3), na(255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units - For flexible Sub-Bands only.
+ For units with version 2.0 and above this is a read-only parameter.
+ The scanning step to be used for generating the frequency subset."
+ ::= { bwaVLFrequencyDefinition 3 }
+
+
+ bwaVLFrequencySubsetTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BwaVLFrequencySubsetEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB and to AU/BU.
+ Not applicable to SU/RB with SW version 4.0 and higher.
+ The Frequency Subset Table that includes all frequencies from
+ the selected Sub-band."
+ ::= { bwaVLFrequencyDefinition 4 }
+
+ bwaVLFrequencySubsetEntry OBJECT-TYPE
+ SYNTAX BwaVLFrequencySubsetEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB and to AU/BU.
+ Not applicable to SU/RB with SW version 4.0 and higher.
+ An entry in the Frequency Subset Table. "
+ INDEX { bwaVLFrequencySubsetTableIdx }
+ ::= { bwaVLFrequencySubsetTable 1 }
+
+ BwaVLFrequencySubsetEntry ::= SEQUENCE {
+ bwaVLFrequencySubsetTableIdx INTEGER,
+ bwaVLFrequencySubsetFrequency INTEGER,
+ bwaVLFrequencySubsetActive INTEGER,
+ bwaVLFrequencySubsetFrequencyNew DisplayString
+ }
+
+ bwaVLFrequencySubsetTableIdx OBJECT-TYPE
+ SYNTAX INTEGER (1..40)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB and to AU/BU.
+ Not applicable to SU/RB with SW version 4.0 and higher.
+ An index of an entry in the Frequency subset Table."
+ ::= { bwaVLFrequencySubsetEntry 1 }
+
+
+ bwaVLFrequencySubsetFrequency OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB and to AU/BU.
+ Not applicable to SU/RB with SW version 4.0 and higher.
+ Applicable to all units with HW revision B and lower
+ (for units with HW revision C and higher replaced by
+ bwaVLFrequencySubsetFrequencyNew to support a
+ resolution of 0.5 MHz).
+ The frequency in MHz of an entry in the Frequency Subset table."
+ ::= { bwaVLFrequencySubsetEntry 2 }
+
+ bwaVLFrequencySubsetActive OBJECT-TYPE
+ SYNTAX INTEGER {active (1) , notActive (2)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB and to AU/BU.
+ Not applicable to SU/RB with SW version 4.0 and higher.
+ The status of an entry in the Frequency subset Table.
+ The frequency of an active entry will be included in the
+ final list of frequencies to be used for scanning."
+ ::= { bwaVLFrequencySubsetEntry 3 }
+
+ bwaVLFrequencySubsetFrequencyNew OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Not applicable to SU/RB with SW version 4.0 and higher.
+ The frequency in MHz of an entry in the Frequency Subset table.
+ (Replaces bwaVLFrequencySubsetFrequency to support a resolution
+ of 0.5 MHz for units with HW revision C and higher)."
+ ::= { bwaVLFrequencySubsetEntry 4 }
+
+ bwaVLSetSelectedFreqSubset OBJECT-TYPE
+ SYNTAX INTEGER {setSelectedFreqsSubset(1) ,cancel (2)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB and to AU/BU.
+ Not applicable to SU/RB with SW version 4.0 and higher.
+ Apply the selected subset.
+ After the next reset the new subset will be used."
+ ::= { bwaVLFrequencyDefinition 5 }
+
+
+
+
+ bwaVLCurrentFrequencySubsetTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BwaVLCurrentFrequencySubsetEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB and to AU/BU.
+ Not applicable to SU/RB with SW version 4.0 and higher.
+ The Current Frequency Subset table. In SU/RB it includes all
+ frequencies that are currently used for scanning.
+ In AU/BU it includes all frequencies that can be used by the
+ DFS mechanism (if applicable)"
+ ::= { bwaVLFrequencyDefinition 6 }
+
+ bwaVLCurrentFrequencySubsetEntry OBJECT-TYPE
+ SYNTAX BwaVLCurrentFrequencySubsetEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB and to AU/BU.
+ An entry in the Current Frequency Subset Table. "
+ INDEX { bwaVLCurrentFrequencySubsetTableIdx }
+ ::= { bwaVLCurrentFrequencySubsetTable 1 }
+
+ BwaVLCurrentFrequencySubsetEntry ::= SEQUENCE {
+ bwaVLCurrentFrequencySubsetTableIdx INTEGER,
+ bwaVLCurrentFrequencySubsetFrequency INTEGER,
+ bwaVLCurrentFrequencySubsetFrequencyNew DisplayString
+ }
+
+ bwaVLCurrentFrequencySubsetTableIdx OBJECT-TYPE
+ SYNTAX INTEGER (1..40)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB and to AU/BU.
+ An index of an entry in the Current Frequency subset Table.
+ Not applicable to SU/RB with SW version 4.0 and higher."
+ ::= { bwaVLCurrentFrequencySubsetEntry 1 }
+
+
+ bwaVLCurrentFrequencySubsetFrequency OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Not applicable to SU/RB with SW version 4.0 and higher.
+ Applicable to all units with HW revision B and lower
+ (for units with HW revision C and higher replaced by
+ bwaVLCurrentFrequencySubsetFrequencyNew to support
+ a resolution of 0.5 MHz).
+ The frequency in MHz of an entry in the Current Frequency Subset table."
+ ::= { bwaVLCurrentFrequencySubsetEntry 2 }
+
+ bwaVLCurrentFrequencySubsetFrequencyNew OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. Not applicable to SU/RB with SW version 4.0 and higher.
+ The frequency in MHz of an entry in the Current Frequency Subset table.
+ (Replaces bwaVLCurrentFrequencySubsetFrequency to support a
+ resolution of 0.5 MHz for units with HW revision C and higher)."
+ ::= { bwaVLCurrentFrequencySubsetEntry 3 }
+
+ bwaVLCurrentAUOperatingFrequency OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU with HW revision B and lower
+ (for units with HW revision C and higher replaced by
+ bwaVLCurrentUOperatingFrequencyNew to support a resolution
+ of 0.5 MHz).
+ The operating frequency in MHz.
+ For 5.8GHz products with SW version below 2.0 the range is
+ 5740 to 5830 MHz using 10MHz resolution.
+ For units with SW version 2.0 and up the range is as defined
+ in the selected Sub Band."
+ ::= { bwaVLFrequencyDefinition 7 }
+
+ bwaVLCurrentAUOperatingFrequencyNew OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU. The operating frequency in MHz.
+ (Replaces bwaVLCurrentAUOperatingFrequency to support
+ a resolution of 0.5 MHz for units with HW revision C and higher).
+ For 5.8GHz products with SW version below 2.0 the range is
+ 5740 to 5830 MHz using 10MHz resolution.
+ For units with SW version 2.0 and up the range is as defined
+ in the selected Sub Band."
+ ::= { bwaVLFrequencyDefinition 13 }
+
+ bwaVLAUDefinedFrequency OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU with HW revision B and lower
+ (for units with HW revision C and higher replaced by
+ bwaVLAUDefinedFrequencyNew to support a resolution of 0.5 MHz).
+ For 5.8GHz products with SW version below 2.0 this is the frequency
+ in MHz of the AU/BU after the next reset.
+ For units with SW version 2.0 and up this is the frequency in MHz
+ to use when the DFS Option is disabled.
+ For 5.8GHz products with SW version below 2.0 the range is
+ 5740 to 5830 MHz using 10MHz resolution.
+ For units with SW version 2.0 and up the range is as defined
+ in the selected Sub Band."
+ ::= { bwaVLFrequencyDefinition 8 }
+
+ bwaVLAUDefinedFrequencyNew OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU.
+ For 5.8GHz products with SW version below 2.0 this is the
+ frequency in MHz of the AU/BU after the next reset.
+ For units with SW version 2.0 and up this is the
+ frequency in MHz to use when the DFS Option is disabled.
+ (Replaces bwaVLAUDefinedFrequency to support a resolution
+ of 0.5 MHz for units with HW revision C and higher).
+ For 5.8GHz products with SW version below 2.0 the range
+ is 5740 to 5830 MHz using 10MHz resolution.
+ For units with SW version 2.0 and up the range is as
+ defined in the selected Sub Band."
+ ::= { bwaVLFrequencyDefinition 14 }
+
+ bwaVLCurrentSUOperatingFrequency OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ The frequency used currently by the unit.
+ For 5.8GHz products with SW version below 2.0 the range is
+ 5740 to 5830 MHz using 10MHz resolution.
+ For units with SW version 2.0 and up the range is as defined
+ in the selected Sub Band."
+ ::= { bwaVLFrequencyDefinition 9 }
+
+bwaVLSubBandSelect OBJECT IDENTIFIER ::= {bwaVLFrequencyDefinition 10}
+
+
+ bwaVLSelectSubBandIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units with SW version below 4.0
+ For units with SW version 4.0 and up it is applicable
+ only for AU/BU. For SU/RB it defines only the sub-band
+ for the Spectrum Analyzer.
+ The ID of the sub-band used by the unit."
+ ::= { bwaVLSubBandSelect 1 }
+
+
+
+bwaVLDFSParameters OBJECT IDENTIFIER ::= {bwaVLFrequencyDefinition 11}
+
+ bwaVLDFSOption OBJECT-TYPE
+ SYNTAX INTEGER { disable (1) , enable (2), na (255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Enabling/disabling the DFS Algorithm.
+ Not applicable if DFS Option is not supported by the current Sub Band."
+ ::= { bwaVLDFSParameters 1 }
+
+ bwaVLDFSChannelCheckTime OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Defines the time the unit checks the channel for presence of
+ radar signals and does not transmit after power up or association
+ or after moving to a new channel due to detecting radar in the used
+ channel. Range: 1 to 3600 (seconds)."
+ ::= { bwaVLDFSParameters 3 }
+
+
+ bwaVLDFSChannelAvoidancePeriod OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Defines the time after detecting radar signals in a channel of
+ avoiding using the channel or adjacent channels in
+ accordance with the bandwidth. Range: 1 to 60 (minutes)."
+ ::= { bwaVLDFSParameters 4 }
+
+
+ bwaVLDFSSuWaitingOption OBJECT-TYPE
+ SYNTAX INTEGER { disable (1) , enable (2), na(255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Defines whether the associated SUs should wait for this AU/BU
+ after it stopped transmitting due to radar detection, before
+ they starts scanning for other AUs/BUs."
+ ::= { bwaVLDFSParameters 5 }
+
+
+ bwaVLDFSClearRadarDetectedChannelsAfterReset OBJECT-TYPE
+ SYNTAX INTEGER { cancel (1), clearRadarChannels (2), na(255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Clear Radar Detected and Adjacent to Radar channels after unit reset.
+ Returns the unit to operate in default frequency."
+ ::= { bwaVLDFSParameters 6 }
+
+ bwaVLDFSRadarDetectionChannelsTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BwaVLDFSRadarDetectionChannelsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Applicable only when DFS option is on.
+ Displays the current channels defined in the sub-band and their radar
+ detection status."
+ ::= { bwaVLDFSParameters 7 }
+
+ bwaVLDFSRadarDetectionChannelsEntry OBJECT-TYPE
+ SYNTAX BwaVLDFSRadarDetectionChannelsEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ An entry in the bwaVLDFSRadarDetectionChannelsTable."
+ INDEX { bwaVLDFSChannelIdx }
+ ::= { bwaVLDFSRadarDetectionChannelsTable 1 }
+
+ BwaVLDFSRadarDetectionChannelsEntry ::= SEQUENCE {
+ bwaVLDFSChannelIdx INTEGER,
+ bwaVLDFSChannelFrequency INTEGER,
+ bwaVLDFSChannelRadarStatus INTEGER,
+ bwaVLDFSChannelFrequencyNew DisplayString }
+
+ bwaVLDFSChannelIdx OBJECT-TYPE
+ SYNTAX INTEGER (1..40)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only. Read-only.
+ The index of the entry in the
+ bwaVLDFSRadarDetectionChannelsTable."
+ ::= { bwaVLDFSRadarDetectionChannelsEntry 1 }
+
+ bwaVLDFSChannelFrequency OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU with HW revision B and lower
+ (for units with HW revision C and higher replaced by
+ bwaVLDFSChannelFrequency New to support a resolution
+ of 0.5 MHz).
+ The frequency in MHz of a channel in the DFS Radar
+ Detection Channels Table."
+ ::= { bwaVLDFSRadarDetectionChannelsEntry 2 }
+
+ bwaVLDFSChannelRadarStatus OBJECT-TYPE
+ SYNTAX INTEGER { radarFree (1),
+ adjacentToRadar (2),
+ radarDetected (3) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ The radar detection status of a channel in
+ bwaVLDFSRadarDetectionChannelTable."
+ ::= { bwaVLDFSRadarDetectionChannelsEntry 3 }
+
+ bwaVLDFSChannelFrequencyNew OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU. The frequency of a channel in the
+ DFS Radar Detection Channels Table.
+ (Replaces bwaVLDFSChannelFrequency to support a
+ resolution of 0.5 MHz for units with HW revision C and higher)."
+ ::= { bwaVLDFSRadarDetectionChannelsEntry 4 }
+
+ bwaVLDFSMinimumPulsesToDetect OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Defines the minimum number of pulses to detect a radar.
+ Range: 1 - 100."
+ ::= { bwaVLDFSParameters 8 }
+
+
+bwaVLDFSChannelReuseParameters OBJECT IDENTIFIER ::= {bwaVLDFSParameters 9}
+
+ bwaVLDFSChannelReuseOption OBJECT-TYPE
+ SYNTAX INTEGER { disable (1) , enable (2), na (255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Enabling/disabling the DFS Channel Reuse Algorithm.
+ Not applicable if DFS Option is not supported by the current Sub Band."
+ ::= { bwaVLDFSChannelReuseParameters 1 }
+
+ bwaVLDFSRadarActivityAssessmentPeriod OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Range: 1 to 12 (Houres)."
+ ::= { bwaVLDFSChannelReuseParameters 2 }
+
+ bwaVLDFSMaximumNumberOfDetectionsInAssessmentPeriod OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Range: 1 to 10 (Times)."
+ ::= { bwaVLDFSChannelReuseParameters 3 }
+
+ bwaVLCountryCodeLearningBySU OBJECT-TYPE
+ SYNTAX INTEGER { disable(1), enable(2), na(255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ Starting with 4.0 it is nor applicable for BWA 4900 and BWA PtP.
+ Defines whether the SUs learn the country code of the AU."
+ ::= { bwaVLFrequencyDefinition 12 }
+
+
+-- AUTOMATIC SUB BAND SELECT BEGIN
+
+ bwaVLAutoSubBandSelect OBJECT IDENTIFIER ::= { bwaVLFrequencyDefinition 15 }
+
+ bwaVLAutoSubBandSelectedFreqSubset OBJECT-TYPE
+ SYNTAX INTEGER { setAllSelectedFreqsSubset(1), cancel (2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB with SW version 4.0 and higher.
+ Apply the selected subset. After the next reset the new
+ subset will be used for scanning."
+ ::= { bwaVLAutoSubBandSelect 1 }
+
+ bwaVLAutoSubBandFrequencySubsetTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BwaVLAutoSubBandFrequencySubsetEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB with SW version 4.0 and higher.
+ The Frequency Subset Table that includes all available
+ sub-bands and all the frequencies in these sub-bands."
+ ::= { bwaVLAutoSubBandSelect 2 }
+
+ bwaVLAutoSubBandFrequencySubsetEntry OBJECT-TYPE
+ SYNTAX BwaVLAutoSubBandFrequencySubsetEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB with SW version 4.0 and higher.
+ An entry in the Frequency Subset Table. "
+ INDEX { bwaVLAutoSubBandFrequencySubsetBandIdx, bwaVLAutoSubBandFrequencySubsetFrequencyIdx }
+ ::= { bwaVLAutoSubBandFrequencySubsetTable 1 }
+
+ BwaVLAutoSubBandFrequencySubsetEntry ::= SEQUENCE {
+ bwaVLAutoSubBandFrequencySubsetBandIdx INTEGER,
+ bwaVLAutoSubBandFrequencySubsetFrequencyIdx INTEGER,
+ bwaVLAutoSubBandFrequencySubsetActive INTEGER,
+ bwaVLAutoSubBandFrequencySubsetFrequency DisplayString
+ }
+
+ bwaVLAutoSubBandFrequencySubsetBandIdx OBJECT-TYPE
+ SYNTAX INTEGER (1..5)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB with SW version 4.0 and higher.
+ The index of the applicable Sub Band.
+ This is the Sub Band ID of the relevant entry in
+ the Country Dependent Parameters table.
+ Serves also as an index of the entry in the
+ Frequency subset Table."
+ ::= { bwaVLAutoSubBandFrequencySubsetEntry 1 }
+
+ bwaVLAutoSubBandFrequencySubsetFrequencyIdx OBJECT-TYPE
+ SYNTAX INTEGER (1..40)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB with SW version 4.0 and higher.
+ The index of the applicable frequency in the
+ applicable Sub Band.
+ Serves also as an index of the entry in the
+ Frequency subset Table."
+ ::= { bwaVLAutoSubBandFrequencySubsetEntry 2 }
+
+
+ bwaVLAutoSubBandFrequencySubsetActive OBJECT-TYPE
+ SYNTAX INTEGER {active (1) , notActive (2)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB with SW version 4.0 and higher.
+ The status of an entry in the Auto Sub Band Frequency subset Table.
+ The frequency of an active entry will be included in the
+ final list of frequencies to be used for scanning."
+ ::= { bwaVLAutoSubBandFrequencySubsetEntry 3 }
+
+ bwaVLAutoSubBandFrequencySubsetFrequency OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB with SW version 4.0 and higher.
+ The frequency in MHz of the entry in the Auto Sub Band Frequency Subset table."
+ ::= { bwaVLAutoSubBandFrequencySubsetEntry 4 }
+
+
+-- AUTOMATIC SUB BAND SELECT END
+
+
+bwaVLATPC OBJECT IDENTIFIER ::= {bwaVLAirInterface 13}
+
+ bwaVLAtpcOption OBJECT-TYPE
+ SYNTAX INTEGER { disable (1) , enable (2) , na (255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable all units.
+ Enabling/disabling the ATPC Algorithm."
+ ::= { bwaVLATPC 1 }
+
+ bwaVLDeltaFromMinSNRLevel OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable AU/BU only.
+ The Minimum SNR Level plus the value of this parameter define the
+ maximum desired level of the average SNR at the AU/BU.
+ If the ATPC Option is enabled, than if the received SNR is above
+ the maximum desired level, the AU/BU will transmit Power-Down
+ messages to the applicable SU/RB.
+ Range: 4 to 20 (dB)."
+ ::= { bwaVLATPC 2 }
+
+ bwaVLMinimumSNRLevel OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable AU/BU only.
+ Defines the minimum desired level of the average SNR at the AU/BU.
+ Below this level, if *AtpcOption is enabled, the AU/BU will transmit
+ ATPC Power-Up messages to the applicable SU/RB.
+ The *MinimumSNRLevel cannot be higher than *MaximumSNRLevel.
+ Range: 4 to 60 (dB)."
+ ::= { bwaVLATPC 3 }
+
+
+ bwaVLMinimumIntervalBetweenATPCMessages OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable AU/BU only.
+ The minimum interval between two consecutive AU/BU to SU/RB messages.
+ Range: 1 to 3600 (Sec)."
+ ::= { bwaVLATPC 4 }
+
+
+
+ bwaVLPowerLevelSteps OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable AU/BU only.
+ The step in dB that the SU/RB will use when receiving an ATPC
+ Power-Up/Power-Down message.
+ Range: 1 to 20 (dB)."
+ ::= { bwaVLATPC 6 }
+
+bwaVLCellDistanceParameters OBJECT IDENTIFIER ::= {bwaVLAirInterface 15}
+
+ bwaVLCellDistanceMode OBJECT-TYPE
+ SYNTAX INTEGER { automatic (1) , manual (2), na (255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable AU/BU only.
+ The selected mode of deciding on Cell Distance."
+ ::= { bwaVLCellDistanceParameters 1 }
+
+ bwaVLFairnessFactor OBJECT-TYPE
+ SYNTAX INTEGER { na (255)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable AU/BU only.
+ Not applicable to BWA-PtP products for SW version below 4.0..
+ The percentage of the maximum distance that is taken into
+ account in the time slot calculation. Range: 0 to 100
+ (Percent). A value of 0 means the minimal slot size
+ (9 microseconds).
+ BWA-PtP products with SW version below 4.0 return na."
+ ::= { bwaVLCellDistanceParameters 2 }
+
+ bwaVLMeasuredCellDistance OBJECT-TYPE
+ SYNTAX INTEGER {below-2-Km(1)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable AU/BU only.
+ The Maximum Cell Distance as calculated by the AU/BU.
+ Range: 0 to 54 (Kilometers)."
+ ::= { bwaVLCellDistanceParameters 3 }
+
+ bwaVLUnitWithMaxDistance OBJECT-TYPE
+ SYNTAX MacAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable AU only.
+ Not applicable to BWA-PtP units.
+ The MAC address of the unit with the maximum distance
+ from the AU."
+ ::= { bwaVLCellDistanceParameters 4 }
+
+ bwaVLPerSuDistanceLearning OBJECT-TYPE
+ SYNTAX INTEGER { disable (1) , enable (2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Aplicable to AU only. Applicable only if Cell Distance Mode is
+ set to Automatic. When disabled, all SUs in the cell will use
+ for the ACK Timeout the computed distance of the farthest SU.
+ When enabled, each SU will use its own computed distance"
+ ::= { bwaVLCellDistanceParameters 5 }
+
+ bwaVLScanningMode OBJECT-TYPE
+ SYNTAX INTEGER { passive (1), active (2)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ The scanning mode. In cells where the DFS Option is enabled
+ Scanning Mode is forced to Passive."
+ ::= { bwaVLAirInterface 16 }
+
+ bwaVLAntennaGain OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. Read-write in units where
+ bwaVLAntennaGainChange is supported.
+ Read-only in units where bwaVLAntennaGainChange is not supported.
+ The net gain (including cable attenuation for detached antennas) of
+ the antenna.
+ Range: 0 - to Maximum EIRP defined by country code + 10 (dBi).
+ A value of -2 (this value is configurable only in factory)
+ means don't care.
+ A value of -1 (this value is configurable only in factory)
+ means that the unit will not transmit until the actual value
+ is configured."
+ ::= { bwaVLAirInterface 17 }
+
+bwaVLSpectrumAnalysisParameters OBJECT IDENTIFIER ::= {bwaVLAirInterface 18}
+
+ bwaVLSpectrumAnalysisChannelScanPeriod OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The period of staying on each channel for information gathering
+ when performing Spectrum analysis.
+ Range: 2-30 seconds."
+ ::= { bwaVLSpectrumAnalysisParameters 1 }
+
+ bwaVLSpectrumAnalysisScanCycles OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The number of scanning cycles when performing Spectrum Analysis.
+ Range: 1-100."
+ ::= { bwaVLSpectrumAnalysisParameters 2 }
+
+ bwaVLAutomaticChannelSelection OBJECT-TYPE
+ SYNTAX INTEGER { disable (1), enable (2), na (255)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Defines weather the AU/BU shall choose the most noise free channel
+ upon startup after spectrum analysis."
+ ::= { bwaVLSpectrumAnalysisParameters 3 }
+
+ bwaVLSpectrumAnalysisActivation OBJECT-TYPE
+ SYNTAX INTEGER { cancelOperation (1), activateNow (2)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Activates spectrum analysis, the unit is automatically reset upon
+ activation."
+ ::= { bwaVLSpectrumAnalysisParameters 4 }
+
+ bwaVLSpectrumAnalysisStatus OBJECT-TYPE
+ SYNTAX INTEGER { inactive (1), currentlyActive (2)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Defines weather the unit is currently under performing
+ a spectrum analysis process."
+ ::= { bwaVLSpectrumAnalysisParameters 5 }
+
+ bwaVLResetSpectrumCounters OBJECT-TYPE
+ SYNTAX INTEGER { cancelOperation (1), resetCounters (2)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Resets the spectrum analysis counters."
+ ::= { bwaVLSpectrumAnalysisParameters 6 }
+
+ bwaVLSpectrumAnalysisInformationTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BwaVLSpectrumAnalysisInformationEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The spectrum analysis information table."
+ ::= { bwaVLSpectrumAnalysisParameters 7 }
+
+ bwaVLSpectrumAnalysisInformationEntry OBJECT-TYPE
+ SYNTAX BwaVLSpectrumAnalysisInformationEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The spectrum analysis information table entry."
+ INDEX { bwaVLSpectrumAnalysisInformationTableIdx }
+ ::= { bwaVLSpectrumAnalysisInformationTable 1 }
+
+ BwaVLSpectrumAnalysisInformationEntry ::= SEQUENCE {
+ bwaVLSpectrumAnalysisInformationTableIdx INTEGER,
+ bwaVLSpectrumAnalysisInformationChannel DisplayString,
+ bwaVLSpectrumAnalysisInformationSignalCount INTEGER,
+ bwaVLSpectrumAnalysisInformationSignalSNR INTEGER,
+ bwaVLSpectrumAnalysisInformationSignalWidth INTEGER,
+ bwaVLSpectrumAnalysisInformationOFDMFrames INTEGER
+ }
+
+
+ bwaVLSpectrumAnalysisInformationTableIdx OBJECT-TYPE
+ SYNTAX INTEGER (1..60)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ A read only table index for a Spectrum Analysis Information entry in the
+ Spectrum Analysis Information Table."
+ ::= { bwaVLSpectrumAnalysisInformationEntry 1 }
+
+ bwaVLSpectrumAnalysisInformationChannel OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The channels in the Spectrum Analysis Information Table.
+ If the unit is currently under spectrum analysis the channels would
+ be those on which the analysis is currently performed.
+ If the unit is in normal mode the channels would be the those on
+ which the last analysis was performed."
+ ::= { bwaVLSpectrumAnalysisInformationEntry 2 }
+
+ bwaVLSpectrumAnalysisInformationSignalCount OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The number of signals (excluding OFDM frames) detected in the channel.
+ If the unit is currently under spectrum analysis the count would
+ be of the analysis that is currently performed.
+ If the unit is in normal mode the count would be of the last
+ analysis performed."
+ ::= { bwaVLSpectrumAnalysisInformationEntry 3 }
+
+ bwaVLSpectrumAnalysisInformationSignalSNR OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The approximate SNR of the signals (excluding OFDM frames)
+ detected in the channel.
+ If the unit is currently under spectrum analysis the SNR would
+ be of the analysis that is currently performed.
+ If the unit is in normal mode the SNR would be of the last
+ analysis performed."
+ ::= { bwaVLSpectrumAnalysisInformationEntry 4 }
+
+ bwaVLSpectrumAnalysisInformationSignalWidth OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The average width of the signals (excluding OFDM frames)
+ detected in the channel.
+ If the unit is currently under spectrum analysis the width would
+ be of the analysis that is currently performed.
+ If the unit is in normal mode the width would be of the last
+ analysis performed."
+ ::= { bwaVLSpectrumAnalysisInformationEntry 5 }
+
+ bwaVLSpectrumAnalysisInformationOFDMFrames OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The number of OFDM frames detected in the channel.
+ If the unit is currently under spectrum analysis the count would
+ be of the analysis that is currently performed.
+ If the unit is in normal mode the count would be of the last
+ analysis performed."
+ ::= { bwaVLSpectrumAnalysisInformationEntry 6 }
+
+ bwaVLMaxNumOfAssociationsLimit OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ Not applicable to BWA-PtP products.
+ Shows the limit for the number of SUs that can be associated
+ with the AU.
+ For AU-BS, AU-SA if Data Encryption is enabled, the upper
+ limit is 124, otherwise it is 512.
+ For AUS-BS, AUS-SA with SW version 4.0 and higher the upper limit
+ is 8 or 25 (via licensing).
+ For AUS-BS, AUS-SA with SW version below 4.0 the upper limit is 5.
+ BWA-PtP products return 65535."
+ ::= { bwaVLAirInterface 19 }
+
+bwaVLDisassociate OBJECT IDENTIFIER ::= {bwaVLAirInterface 20}
+
+ bwaVLDisassociateAllSUs OBJECT-TYPE
+ SYNTAX INTEGER { cancelOperation (1), disassociateAllSUs(2)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ The AU shall disassociate all its associated units."
+ ::= { bwaVLDisassociate 1 }
+
+ bwaVLDisassociateSuByMacAddress OBJECT-TYPE
+ SYNTAX MacAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ The AU shall disassociate the SU with the configured MAC address."
+ ::= { bwaVLDisassociate 2 }
+
+ bwaVLTxControl OBJECT-TYPE
+ SYNTAX INTEGER { on (1), off(2)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Tx Control of the AU/BU.
+ Starting with version 4.0 it is run-time.
+ For SW version below 4.0 the unit reset itself.
+ If set to ethernetStatusControl, the unit will not transmit
+ if the Ethernet link is down.
+ This parameter can be configured only via the ethernet port."
+ ::= { bwaVLAirInterface 21 }
+
+ bwaVLLostBeaconsWatchdogThreshold OBJECT-TYPE
+ SYNTAX INTEGER ( 0 | 100..1000 )
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ The number of unsuccessful consecutive transmissions beacons
+ before Internal refresh is performed.
+ 0 means that the lost beacons watchdog is not
+ used and internal refresh is not performed."
+ ::= { bwaVLAirInterface 22}
+
+ bwaVLTransmitPower OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units with SW version 4.0 and higher.
+ The uniform transmit power for all modulation levels. For a specific
+ modulation level the effective transmit power (bwaVLTxPower) is
+ the minimum between the uniform transmit power and the maximum
+ transmit power for that modulation level."
+ ::= { bwaVLAirInterface 23 }
+
+ bwaVLMaximumTxPower OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to only SU/RB with SW version 4.0 and higher.
+ The Maximum Transmit Power for all modulation levels.
+ The Maximum Transmit Power for a specific modulation level is the
+ minimum between this parameter and the hardware limitation for
+ that modulation level"
+ ::= { bwaVLAirInterface 24 }
+
+ bwaVLCountryCodeParameters OBJECT IDENTIFIER ::= {bwaVLAirInterface 25}
+
+ bwaLCountryCodeReApply OBJECT-TYPE
+ SYNTAX INTEGER { reapply(1),cancel(2), na(255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Re-apply country code parameters."
+ ::= { bwaVLCountryCodeParameters 1 }
+
+
+-- Service Params
+-- ==============
+ bwaVLServiceParameters OBJECT IDENTIFIER ::= {bwaVLMib 7}
+
+-- bwaVLMirCirOption OBJECT-TYPE
+-- SYNTAX INTEGER {disable (1),
+-- enable (2),
+-- na (255)}
+-- MAX-ACCESS read-write
+-- STATUS current
+-- DESCRIPTION
+-- "Applicable to AU and SU. Read-only in SU.
+-- The setting in the AU enables/disables the MIR/CIR support
+-- feature for all SUs served by the AU."
+-- ::= { bwaVLServiceParameters 1 }
+
+ bwaVLMirDownlink OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ The Maximum Information Rate (MIR) from AU/BU to SU/RB.
+ MIR must be above bwaVLCirDownlink value.
+ Range for set: 128 to 2,048 (Kbps) for SU-3 with SW version below 4.0,
+ 128 to 3,072 (Kbps) for SU-3 with SW version 4.0 and higher,
+ 128 to 3,968 (Kbps) for SU-6 with SW version less than 4.0,
+ 128 to 6,016 (Kbps) for SU-6 with SW version greater than 4.0,
+ 128 to 14,976 (Kbps) for SU-24,
+ 128 to 53,888 (Kbps) for SU-BD and SU-54,
+ 128 to 6,912 (Kbps) for RB-14,
+ 128 to 22,016 (Kbps) for RB-28,
+ 128 to 107,904 (Kbps) for RB-100.
+ 128 to 6,016 (Kbps) for SU-I.
+ The actual value (Get) will be the entered value rounded to the nearest
+ multiple of 128 (N*128)."
+ ::= { bwaVLServiceParameters 2 }
+
+ bwaVLMirUplink OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ The Maximum Information Rate (MIR) from SU/RB to AU/BU.
+ MIR must be above bwaVLCirUplink value.
+ Range for set: 128 to 2,048 (Kbps) for SU-3,
+ 128 to 3,968 (Kbps) for SU-6 with SW version less than 4.0,
+ 128 to 4,096 (Kbps) for SU-6 with SW version greater than 4.0,
+ 128 to 14,976 (Kbps) for SU-24,
+ 128 to 53,888 (Kbps) for SU-BD and SU-54,
+ 128 to 6,912 (Kbps) for RB-14,
+ 128 to 22,016 (Kbps) for RB-28,
+ 128 to 107,904 (Kbps) for RB-100.
+ 128 to 2,048 (Kbps) for SU-I.
+ The actual value (Get) will be the entered value rounded to the nearest
+ multiple of 128 (N*128)."
+ ::= { bwaVLServiceParameters 3 }
+
+
+ bwaVLCirDownlink OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU only.
+ Not applicable to BWA-PtP products.
+ The Committed Information Rate (CIR) from AU to SU.
+ CIR must be below bwaVLMirDownlink value.
+ Range for Set:
+ 0 to 2,048 (Kbps) for SU-3 with SW version below 4.0,
+ 0 to 3,072 (Kbps) for SU-3 with SW version 4.0 and higher,
+ 0 to 3,968 (Kbps) for SU-6 with SW version less than 4.0,
+ 0 to 6,016 (Kbps) for SU-6 with SW version greater than 4.0
+ 0 to 14,976 (Kbps) for SU-24,
+ 0 to 45,056 (Kbps) for SU-BD and SU-54.
+ 0 to 6,016 (Kbps) for SU-I.
+ The actual value (Get) will be the entered value rounded to the
+ nearest multiple of 128 (N*128).
+ BWA-PtP products will return 65535."
+ ::= { bwaVLServiceParameters 4 }
+
+
+ bwaVLCirUplink OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU only.
+ Not applicable to BWA-PtP products.
+ The Committed Information Rate (CIR) from SU to AU.
+ CIR must be below bwaVLMirUplink value.
+ Range for Set:
+ 0 to 2,048 (Kbps) for SU-3,
+ 0 to 3,968 (Kbps) for SU-6 with SW version less than 4.0,
+ 0 to 4,096 (Kbps) for SU-6 with SW version greater than 4.0,
+ 0 to 14,976 (Kbps) for SU-24,
+ 0 to 45,056 (Kbps) for SU-BD and SU-54.
+ 0 to 2,048 (Kbps) for SU-I.
+ The actual value (Get) will be the entered value rounded to the nearest
+ multiple of 128 (N*128).
+ BWA-PtP products will return 65535."
+ ::= { bwaVLServiceParameters 5 }
+
+
+ bwaVLMaxDelay OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU only.
+ Not applicable to BWA-PtP products.
+ The maximal time packets may be delayed by the
+ CIR\MIR mechanism. Above the configured maximal period
+ the packets are discarded.
+ Range: 300 to 10000 milliseconds.
+ BWA-PtP products return 65535."
+ ::= { bwaVLServiceParameters 6 }
+
+ bwaVLMaxBurstDuration OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU and SU.
+ Not applicable to BWA-PtP products.
+ The maximum time during which inactivity bonus time
+ can be accumulated for future burst transmissions.
+ Range: 0 to 2000 milliseconds.
+ BWA-PtP products return 65535"
+ ::= { bwaVLServiceParameters 7 }
+
+ bwaVLGracefulDegradationLimit OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ Not applicable to BWA-PtP products.
+ The maximum limit for activating the graceful
+ degradation algorithm.
+ Range: 0 to 70% rate of the CIR.
+ BWA-PtP products return 255."
+ ::= { bwaVLServiceParameters 8 }
+
+ bwaVLMirOnlyOption OBJECT-TYPE
+ SYNTAX INTEGER {disable (1), enable (2), na (255)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ Not applicable to BWA-PtP products.
+ When bwaMirOnly is enabled, it overrides the CIR/MIR
+ algorithm for determining actual information rate and
+ forces the algorithm to operate with MIR parameter
+ settings only. When enabled, the Graceful Degradation
+ algorithm is disabled."
+ ::= { bwaVLServiceParameters 9 }
+
+
+bwaVLTrafficPrioritization OBJECT IDENTIFIER ::= {bwaVLServiceParameters 10}
+
+bwaVLTrafficPriVLAN OBJECT IDENTIFIER ::= {bwaVLTrafficPrioritization 1}
+
+bwaVLVLANPriorityThreshold OBJECT-TYPE
+ SYNTAX INTEGER (1..7)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ If the VLAN Priority's value of the frame is less than or equal to this
+ threshold the frame will get LOW priority, otherwise the frame will get
+ HIGH priority.
+ Untagged frames will get LOW priority"
+ ::= { bwaVLTrafficPriVLAN 1 }
+
+
+bwaVLTrafficPriIPToS OBJECT IDENTIFIER ::= {bwaVLTrafficPrioritization 2}
+
+bwaVLToSPrioritizationOption OBJECT-TYPE
+ SYNTAX INTEGER {disable(1), ipPrecedence(2), dSCP(3) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. Disable/Enable IP ToS prioritization and
+ choose the interpretation of the IP ToS field from IP header.
+ ipPrecedence(2): The IP ToS field is defined by RFC791. In this
+ case the prioritization will be done using the
+ Precedence sub-field of IP ToS. This sub-field
+ has 3 bits, so it can be between 0 and 7.
+ dSCP(3): The IP ToS field is defined by RFC2474. In this
+ case the prioritization will be done using the
+ DSCP sub-field. The size of the sub-field is 6 bits,
+ so the range is 0 to 63."
+ ::= { bwaVLTrafficPriIPToS 1 }
+
+bwaVLIPPrecedenceThreshold OBJECT-TYPE
+ SYNTAX INTEGER (0..7)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. The threshold of Precedence sub-field of IP ToS
+ field from IP Header (RFC791) to be used when the ToS Prioritization
+ Option is set to IP Precedence.
+ If the Precedence sub-field of a frame is less than or equal to this
+ threshold the frame will have LOW priority, otherwise it will get HIGH
+ priority."
+ ::= { bwaVLTrafficPriIPToS 2 }
+
+bwaVLIPDSCPThreshold OBJECT-TYPE
+ SYNTAX INTEGER (0..63)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. The threshold of DSCP sub-field of IP ToS
+ field from IP Header (RFC2474) to be used when ToS Prioritization
+ Option is set to DSCP.
+ If the DSCP sub-field of a frame is less than or equal to this
+ threshold the frame will have LOW priority, otherwise it will get
+ HIGH priority."
+ ::= { bwaVLTrafficPriIPToS 3 }
+
+
+bwaVLTrafficPriUdpTcpPortRange OBJECT IDENTIFIER ::= {bwaVLTrafficPrioritization 3}
+
+bwaVLUdpTcpPortRangePrioritizationOption OBJECT-TYPE
+ SYNTAX INTEGER {disable(1), udpOnly(2), tcpOnly(3), udpANDtcp(4) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. Disable/Enable Prioritization using UDP and/or
+ TCP Port Ranges.
+ udpOnly(2) : prioritization will be done only for UDP packets
+ tcpOnly(3) : prioritization will be done only for TCP packets
+ udpANDtcp(4): prioritization will be done for UDP and TCP packets"
+ ::= { bwaVLTrafficPriUdpTcpPortRange 1 }
+
+bwaVLUdpPortRangeConfig OBJECT IDENTIFIER ::= {bwaVLTrafficPriUdpTcpPortRange 2}
+
+bwaVLUdpPortPriRTPRTCP OBJECT-TYPE
+ SYNTAX INTEGER {rtpANDrtcp(1),rtpOnly(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicale to all units.
+ RTP/RTCP ports prioritization option for UDP packets.
+ rtpANDrtcp(1): the possible RTP and RTCP packet with destination port in the
+ defined port ranges will get HIGH priority
+ rtpOnly(2): only possible RTP packet (packet with even destination port )
+ with destination port in the defined port ranges will get HIGH
+ priority."
+ ::= { bwaVLUdpPortRangeConfig 1 }
+
+bwaVLUdpPortRangeNum OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. The number of entries in the UDP Port Range Table"
+ ::= { bwaVLUdpPortRangeConfig 2 }
+
+bwaVLUdpPortRangeTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BwaVLUdpPortRangeEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. A table of UDP port ranges use for prioritization.
+ The user can define up to 64 ranges.
+ An entry is empty if start is 65535 and end is 0"
+ ::= { bwaVLUdpPortRangeConfig 3 }
+
+bwaVLUdpPortRangeEntry OBJECT-TYPE
+ SYNTAX BwaVLUdpPortRangeEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. A UDP Port Ranges Table entry."
+ INDEX { bwaVLUdpPortRangeIdx }
+ ::= { bwaVLUdpPortRangeTable 1 }
+
+BwaVLUdpPortRangeEntry ::= SEQUENCE {
+ bwaVLUdpPortRangeStart INTEGER,
+ bwaVLUdpPortRangeEnd INTEGER,
+ bwaVLUdpPortRangeIdx INTEGER
+ }
+
+bwaVLUdpPortRangeStart OBJECT-TYPE
+ SYNTAX INTEGER(0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. Start port of an UDP Port Range"
+ ::= { bwaVLUdpPortRangeEntry 1 }
+
+bwaVLUdpPortRangeEnd OBJECT-TYPE
+ SYNTAX INTEGER(0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. End port of an UDP Port Range"
+ ::= { bwaVLUdpPortRangeEntry 2 }
+
+bwaVLUdpPortRangeIdx OBJECT-TYPE
+ SYNTAX INTEGER(1..64)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. UDP Port Range Entry's index "
+ ::= { bwaVLUdpPortRangeEntry 3 }
+
+
+bwaVLUdpPortRangeAdd OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..250))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. Add port range(s) to UDP Port Ranges Table.
+ Get operation will return the empty string.
+ A range is defined - or where is the Start
+ Port of the range and is the End Port. If only is
+ specified the range is -.
+ The value of and are between 0..65535.
+ The user can add several ranges using a comma to separate between ranges.
+ Example: 10-256,99,987-900"
+ ::= { bwaVLUdpPortRangeConfig 4 }
+
+bwaVLUdpPortRangeDelete OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..250))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. Delete port range(s) from UDP Port Ranges Table.
+ Get operation will return the empty string.
+ A range is defined - or where is the Start
+ Port of the range and is the End Port. If only is
+ specified the range is -.
+ The value of and are between 0..65535.
+ The user can delete several ranges using a comma to separate between
+ ranges.
+ Example: 10-256,99,987-900"
+ ::= { bwaVLUdpPortRangeConfig 5 }
+
+bwaVLUdpPortRangeDeleteAll OBJECT-TYPE
+ SYNTAX INTEGER { deleteAll(1), cancelOperation(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. Delete all entries form UDP Port Ranges Table.
+ Get operation will return 1"
+ ::= { bwaVLUdpPortRangeConfig 6 }
+
+
+
+bwaVLTcpPortRangeConfig OBJECT IDENTIFIER ::= {bwaVLTrafficPriUdpTcpPortRange 3}
+
+bwaVLTcpPortPriRTPRTCP OBJECT-TYPE
+ SYNTAX INTEGER {rtpANDrtcp(1),rtpOnly(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. RTP/RTCP ports prioritization option for TCP packets.
+ rtpANDrtcp(1): the possible RTP and RTCP packet with destination port
+ in the defined port ranges will get HIGH priority
+ rtpOnly(2): only possible RTP packet (packet with even destination port )"
+ ::= { bwaVLTcpPortRangeConfig 1 }
+
+bwaVLTcpPortRangeNum OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. The number of entries in the TCP Port Range Table"
+ ::= { bwaVLTcpPortRangeConfig 2 }
+
+bwaVLTcpPortRangeTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BwaVLTcpPortRangeEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Table of TCP Port Ranges use for prioritization.
+ The user can define up to 64 ranges.
+ An entry is empty if start is 65535 and end is 0"
+ ::= { bwaVLTcpPortRangeConfig 3 }
+
+bwaVLTcpPortRangeEntry OBJECT-TYPE
+ SYNTAX BwaVLTcpPortRangeEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. A TCP Port Ranges Table entry."
+ INDEX { bwaVLTcpPortRangeIdx }
+ ::= { bwaVLTcpPortRangeTable 1 }
+
+BwaVLTcpPortRangeEntry ::= SEQUENCE {
+ bwaVLTcpPortRangeStart INTEGER,
+ bwaVLTcpPortRangeEnd INTEGER,
+ bwaVLTcpPortRangeIdx INTEGER
+ }
+
+bwaVLTcpPortRangeStart OBJECT-TYPE
+ SYNTAX INTEGER(0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. Start port of a TCP Port Range"
+ ::= { bwaVLTcpPortRangeEntry 1 }
+
+bwaVLTcpPortRangeEnd OBJECT-TYPE
+ SYNTAX INTEGER(0..65535)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. End port of a TCP Port Range"
+ ::= { bwaVLTcpPortRangeEntry 2 }
+
+bwaVLTcpPortRangeIdx OBJECT-TYPE
+ SYNTAX INTEGER(1..64)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. TCP Port Range Entry's index"
+ ::= { bwaVLTcpPortRangeEntry 3 }
+
+
+bwaVLTcpPortRangeAdd OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..250))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. Add port range(s) to TCP Port Ranges Table.
+ Get operation will return the empty string.
+ A range is defined - or where is the Start
+ Port of the range and is the End Port. If only is specified
+ the range is -.
+ The value of and are between 0..65535.
+ The user can add several ranges using comma to separate between ranges.
+ Example: 10-256,99,987-900"
+ ::= { bwaVLTcpPortRangeConfig 4 }
+
+bwaVLTcpPortRangeDelete OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(0..250))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. Delete port range(s) from TCP Port Ranges Table.
+ Get operation will return the empty string.
+ A range is defined - or where is the Start
+ Port of the range and is the End Port. If only is specified
+ the range is -.
+ The value of and are between 0..65535.
+ The user can delete several ranges using comma to separate between ranges.
+ Example: 10-256,99,987-900"
+ ::= { bwaVLTcpPortRangeConfig 5 }
+
+bwaVLTcpPortRangeDeleteAll OBJECT-TYPE
+ SYNTAX INTEGER { deleteAll(1), cancelOperation(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. Delete all entries form TCP Port Ranges Table
+ Get operation will return 1"
+ ::= { bwaVLTcpPortRangeConfig 6 }
+
+bwaVLWirelessLinkPrioritization OBJECT IDENTIFIER ::= {bwaVLTrafficPrioritization 4}
+
+bwaVLWirelessLinkPrioritizationOption OBJECT-TYPE
+ SYNTAX INTEGER { disable(1), enable(2), na(255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable only to AU with a license for the Wireless Link Prioritization feature and to BU-100.
+ Enable/disable the traffic prioritization over the
+ Wireless Link"
+ ::= { bwaVLWirelessLinkPrioritization 1}
+
+bwaVLlowPriorityAIFS OBJECT-TYPE
+ SYNTAX INTEGER (3..254)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable only to AU with a license for the Wireless Link Prioritization feature and to BU-100.
+ Applicable only if the Wireless Link Prioritization Option is enabled.
+ Define the AIFS (Arbitration Inter-frame Space) that will be used
+ for transmitting Low Priority Traffic"
+ ::= { bwaVLWirelessLinkPrioritization 2}
+
+bwaVLHWRetriesHighPriority OBJECT-TYPE
+ SYNTAX INTEGER (0..14)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable only to AU with a license for the Wireless Link Prioritization feature and to BU-100.
+ Applicable only if the Wireless Link Prioritization Option is enabled.
+ Defines the Maximum number of HW Retries for a unicast data packet
+ that has High Priority"
+ ::= { bwaVLWirelessLinkPrioritization 3}
+
+bwaVLHWRetriesLowPriority OBJECT-TYPE
+ SYNTAX INTEGER (0..14)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable only to AU with a license for the Wireless Link Prioritization feature and to BU-100.
+ Applicable only if the Wireless Link Prioritization Option is enabled.
+ Defines the Maximum number of HW Retries for a unicast data packet
+ that has Low Priority"
+ ::= { bwaVLWirelessLinkPrioritization 4}
+
+bwaVLAUBurstDurationHighPriority OBJECT-TYPE
+ SYNTAX INTEGER (0..40)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable only to AU with a license for the Wireless Link Prioritization feature and to BU-100.
+ Applicable only if the Wireless Link Prioritization Option is enabled.
+ Defines the Maximum duration of burst that can be done by AU with
+ High Priority packets.
+ The time is given in 250 microseconds units"
+ ::= { bwaVLWirelessLinkPrioritization 5}
+
+bwaVLAUBurstDurationLowPriority OBJECT-TYPE
+ SYNTAX INTEGER (0..40)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable only to AU with a license for the Wireless Link Prioritization feature and to BU-100.
+ Applicable only if the Wireless Link Prioritization Option is enabled.
+ Defines the Maximum duration of burst that can be done by AU
+ with Low Priority packets.
+ The time is given in 250 microseconds units"
+ ::= { bwaVLWirelessLinkPrioritization 6}
+
+bwaVLSUBurstDurationHighPriority OBJECT-TYPE
+ SYNTAX INTEGER (0..40)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable only to AU with a license for the Wireless Link Prioritization feature and to BU-100.
+ Applicable only if the Wireless Link Prioritization Option is enabled.
+ Defines the Maximum duration of burst that can be done by SU/RB
+ with High Priority packets.
+ The parameter is configurable in AU and the SUs/RB will learn it
+ form AU/BU.
+ The time is given in 250 microseconds units"
+ ::= { bwaVLWirelessLinkPrioritization 7}
+
+bwaVLSUBurstDurationLowPriority OBJECT-TYPE
+ SYNTAX INTEGER (0..40)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable only to AU with a license for the Wireless Link Prioritization feature and to BU-100.
+ Applicable only if the Wireless Link Prioritization Option is enabled.
+ Defines the Maximum duration of burst that can be done by SU/RB
+ with High Priority packets.
+ The parameter is configurable in AU/BU and the SUs/RB will learn it
+ from AU/BU.
+ The time is given in 250 microseconds units"
+ ::= { bwaVLWirelessLinkPrioritization 8}
+
+
+--DRAP BEGIN
+
+bwaVLDrap OBJECT IDENTIFIER ::= { bwaVLServiceParameters 11 }
+
+bwaVLDrapSupport OBJECT-TYPE
+ SYNTAX INTEGER {disable(1), enable(2), na(255)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU. Not applicable to BWA PtP products.
+ Disable/Enable the DRAP feature"
+ ::= { bwaVLDrap 1 }
+
+bwaVLDrapUdpPort OBJECT-TYPE
+ SYNTAX INTEGER (8000..8200)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU when DRAP support is enabled.
+ Not applicable to BWA PtP products.
+ The UDP port used for the DRAP server"
+ ::= { bwaVLDrap 2 }
+
+bwaVLDrapMaxNumberOfVoiceCalls OBJECT-TYPE
+ SYNTAX INTEGER (0..255)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU when DRAP support is enabled.
+ Not applicable to BWA PtP products.
+ The maximum number of voice calls that can be supported by the AU"
+ ::= { bwaVLDrap 3 }
+
+bwaVLDrapTTL OBJECT-TYPE
+ SYNTAX INTEGER (1..255)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU when DRAP support is enabled.
+ Not applicable to BWA PtP products.
+ The maximum time between two allocation requests"
+ ::= { bwaVLDrap 4 }
+
+bwaVLDrapNoOfActiveVoiceCalls OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU when DRAP support is enabled.
+ Not applicable to BWA PtP products.
+ The current total number of active voice calls."
+ ::= { bwaVLDrap 5 }
+
+
+--DRAP END
+
+bwaVLLowPriorityTrafficMinimumPercent OBJECT-TYPE
+ SYNTAX INTEGER (0..100)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "The minimum percent of the traffic rate that is allocated to the low priority traffic"
+ ::= { bwaVLServiceParameters 12 }
+
+bwaVLSUPMirDownlink OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ The Maximum Information Rate (MIR) from AU to SUP.
+ Range for set: 128 to 12,032 (Kbps).
+ The actual value (Get) will be the entered value rounded to the nearest
+ multiple of 128 (N*128)."
+ ::= { bwaVLServiceParameters 13 }
+
+bwaVLMIRThresholdPercent OBJECT-TYPE
+ SYNTAX INTEGER (0..100)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU only.
+ MIR Threshold Percent"
+ ::= { bwaVLServiceParameters 14 }
+
+
+-- User Filtering Params
+-- =====================
+ bwaVLUserFilterParams OBJECT IDENTIFIER ::= {bwaVLMib 8}
+
+ bwaVLUserFilterOption OBJECT-TYPE
+ SYNTAX INTEGER { disable (1),
+ ipOnly (2),
+ userDefinedAddrOnly (3),
+ pPPoEOnly (4),
+ na (255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Defines user-filtering options.
+ disable: No filtering.
+ iPOnly: Only IP protocol frames pass.
+ userDefinedAddrOnly: Only ip frames to/from user defined IP
+ addresses pass.
+ pPPoE Only: Only PPPoE frames pass."
+ ::= { bwaVLUserFilterParams 1 }
+
+ bwaVLIpFilterTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BwaVLIpFilterEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ An IP Filter Table of up to 8 user defined addresses,
+ or address groups, to be used if the selected User
+ Filtering option is userDefinedAddrOnly."
+ ::= { bwaVLUserFilterParams 2 }
+
+ bwaVLIpFilterEntry OBJECT-TYPE
+ SYNTAX BwaVLIpFilterEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ An IP Filter Table entry."
+ INDEX { bwaVLIpFilterIdx }
+ ::= { bwaVLIpFilterTable 1 }
+
+ BwaVLIpFilterEntry ::= SEQUENCE {
+ bwaVLIpID IpAddress,
+ bwaVLMaskID IpAddress,
+ bwaVLIpFilterRange INTEGER,
+ bwaVLIpFilterIdx INTEGER
+ }
+
+ bwaVLIpID OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ An IP address of an IP Filter Table entry."
+ ::= { bwaVLIpFilterEntry 1 }
+
+ bwaVLMaskID OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ An IP Mask of an IP Filter Table entry. Either a mask
+ or a range, but not both can be used to define an
+ address group. If the range is other than 0, than the mask is
+ ignored and only the range value is used to define the address group."
+ ::= { bwaVLIpFilterEntry 2 }
+
+ bwaVLIpFilterRange OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ An addresses range for the IP Filter Table entry. The
+ first address in the range is the IP address.
+ O means that the range is not used.
+ Either a mask or a range, but not both can be used to
+ define an address group.
+ If the range is other than 0, than the mask is ignored and
+ only the range value is used to define the address group.
+ Range: 0 to 255."
+ ::= { bwaVLIpFilterEntry 3 }
+
+ bwaVLIpFilterIdx OBJECT-TYPE
+ SYNTAX INTEGER (1..8)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ A table index for the IP Filter Table entry."
+ ::= { bwaVLIpFilterEntry 4 }
+
+ bwaVLDeleteOneUserFilter OBJECT-TYPE
+ SYNTAX INTEGER { deletefirstEntry (1), deletesecondEntry (2),
+ deletethirdEntry (3), deletefourthEntry (4),
+ deletefifthEntry (5), deletesixthEntry (6),
+ deleteseventhEntry(7), deleteeighthEntry (8),
+ cancelOperation (9), na (255) }
+
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Deletes a single selected entry from the IP Filter
+ Table."
+ ::= { bwaVLUserFilterParams 3 }
+
+ bwaVLDeleteAllUserFilters OBJECT-TYPE
+ SYNTAX INTEGER { deleteAll (1), cancelOperation (2),
+ na (255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Deletes all entries from the IP Filter Table."
+ ::= { bwaVLUserFilterParams 4 }
+
+ bwaVLDHCPUnicastOverrideFilter OBJECT-TYPE
+ SYNTAX INTEGER { disable (1), enable (2), na (255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ Enables or disables the unicast DHCP messages,
+ overriding the IP Filtering option."
+ ::= { bwaVLUserFilterParams 5 }
+
+
+
+-- Security Params
+-- ==================
+bwaVLSecurityParameters OBJECT IDENTIFIER ::= {bwaVLMib 9}
+
+ bwaVLAuthenticationAlgorithm OBJECT-TYPE
+ SYNTAX INTEGER {openSystem(1) , sharedKey(2)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Enables/disables the authentication encryption option.
+ openSystem: Authentication messages are not encrypted.
+ sharedKey : Authentication messages are encrypted "
+ ::= { bwaVLSecurityParameters 1 }
+
+ bwaVLSUDefaultKeyID OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ The key to be used for encryption of authentication messages
+ and/or data.
+ Range: 1 to 4. "
+ ::= { bwaVLSecurityParameters 2 }
+
+ bwaVLDataEncryptionOption OBJECT-TYPE
+ SYNTAX INTEGER {disable(1) , enable(2)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Enables/disables the data encryption option. "
+ ::= { bwaVLSecurityParameters 3 }
+
+ bwaVLAUDefaultMulticastKeyID OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ The key to be used for encryption of multicasts and broadcasts."
+ ::= { bwaVLSecurityParameters 4 }
+
+ bwaVLSecurityMode OBJECT-TYPE
+ SYNTAX INTEGER {wep(1) , aesOCB(2), fips197(3)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. The fips197 option is applicable only to units with a license to
+ use FIPS 197 algorithm.
+ The encryption algorithm to be used for authentication messages
+ and/or data encryption."
+ ::= { bwaVLSecurityParameters 5 }
+
+
+ bwaVLAuthenticationPromiscuousMode OBJECT-TYPE
+ SYNTAX INTEGER {disable(1) , enable(2)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Enables/disable the promiscuous mode allowing authentication of
+ and communication with all SUs/RB regardless of their security
+ parameters."
+ ::= { bwaVLSecurityParameters 6 }
+
+
+ bwaVLKey1 OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(32))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Key number 1. Accessible only with SNMP Write Community String
+ (administrator password).
+ Valid values: 32 hexadecimal digits."
+ ::= { bwaVLSecurityParameters 7 }
+
+ bwaVLKey2 OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(32))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Key number 2. Accessible only with SNMP Write Community String
+ (administrator password).
+ Valid values: 32 hexadecimal digits."
+ ::= { bwaVLSecurityParameters 8 }
+
+ bwaVLKey3 OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(32))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Key number 3. Accessible only with SNMP Write Community String
+ (administrator password).
+ Valid values: 32 hexadecimal digits."
+ ::= { bwaVLSecurityParameters 9 }
+
+ bwaVLKey4 OBJECT-TYPE
+ SYNTAX DisplayString (SIZE(32))
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Key number 4. Accessible only with SNMP Write Community String
+ (administrator password).
+ Valid values: 32 hexadecimal digits."
+ ::= { bwaVLSecurityParameters 10 }
+
+bwaVLSecurityModeSupport OBJECT-TYPE
+ SYNTAX INTEGER (0..7)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. Returns types of encryption that are supported.
+ 0 - no encryption
+ 1 - WEP
+ 2 - AES OCB
+ 3 - WEP and AES OCB
+ 4 - FIPS-197
+ 5 - FIPS-197 and WEP
+ 6 - FIPS-197 and AES OCB
+ 7 - FIPS-197, AES OCB and WEP"
+ ::= { bwaVLSecurityParameters 12 }
+
+
+-- Performance Params
+-- ==================
+bwaVLPerformanceParams OBJECT IDENTIFIER ::= {bwaVLMib 10}
+
+ bwaVLRTSThreshold OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU and AU.
+ Not applicable to BWA-PtP products.
+ The minimum frame size that requires an RTS/CTS handshake.
+ Range: For units bearing SW version 3.0 and above: 20 to 3400 bytes,
+ for previous SW versions 20 to 1600 bytes.
+ BWA-PtP products return 65535."
+ ::= { bwaVLPerformanceParams 1 }
+
+ bwaVLMinContentionWindow OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU and AU.
+ For units bearing SW version 4.0 and above applicable to
+ BWA PtP products, for previous SW versions not applicable
+ to BWA PtP products.
+ The initial value to be used by the contention window calculation
+ algorithm.
+ Value must be 0 or power of 2 minus 1 (7,15,31...).
+ Range: 0 to 1023, excluding 1 and 3.
+ BWA-PtP products with SW version below 4.0 return 65535."
+ ::= { bwaVLPerformanceParams 3 }
+
+ bwaVLMaxContentionWindow OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU and AU.
+ For units bearing SW version 4.0 and above applicable to
+ BWA PtP products, for previous SW versions not applicable
+ to BWA PtP products.
+ The maximum value to be used by the contention window calculation
+ algorithm.
+ Value must be power of 2 minus 1 (7,15,31...)
+ Range: 7 to 1023."
+ ::= { bwaVLPerformanceParams 4 }
+
+ bwaVLMaximumModulationLevel OBJECT-TYPE
+ SYNTAX INTEGER { level1 (1),
+ level2 (2),
+ level3 (3),
+ level4 (4),
+ level5 (5),
+ level6 (6),
+ level7 (7),
+ level8 (8)
+ }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ If the Adaptive Modulation algorithm is enabled, it sets the
+ Maximum Modulation Level to be used.
+ If The Modulation algorithm is disabled, it sets the Fixed
+ Modulation Level to be used.
+ The range is 1 to 8. 8 is not applicable for units with HW revision A."
+ ::= { bwaVLPerformanceParams 5 }
+
+ bwaVLMulticastModulationLevel OBJECT-TYPE
+ SYNTAX INTEGER { level1 (1),
+ level2 (2),
+ level3 (3),
+ level4 (4),
+ level5 (5),
+ level6 (6),
+ level7 (7),
+ level8 (8)
+ }
+
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ The modulation level for multicast and broadcast data frames.
+ The range is 1 to 8.
+ 8 is not applicable for units with HW revision A."
+ ::= { bwaVLPerformanceParams 6 }
+
+ bwaVLAvgSNRMemoryFactor OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The weight of history in average SNR calculation.
+ The higher is the value, the higher is the weight of history.
+ Range: -1 (Disregard History) to 32."
+ ::= { bwaVLPerformanceParams 7 }
+
+ bwaVLHardwareRetries OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Not applicable if Wireless Link Prioritization is enabled.
+ The maximum number of trials to transmit an unacknowledged
+ frame in each Hardware Retrial phase.
+ Range : 1 to 14."
+ ::= { bwaVLPerformanceParams 8 }
+
+
+bwaVLAdaptiveModulationParams OBJECT IDENTIFIER ::= {bwaVLPerformanceParams 9}
+
+ bwaVLAdaptiveModulationAlgorithmOption OBJECT-TYPE
+ SYNTAX INTEGER { disable (1) , enable (2), na (255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Enables/disables the adaptive modulation level decision mechanism."
+ ::= { bwaVLAdaptiveModulationParams 1 }
+
+
+ bwaVLSoftwareRetrySupport OBJECT-TYPE
+ SYNTAX INTEGER { disable (1) , enable (2), na (255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Read-only for units with version 2.0.
+ Not applicable for units with SW version 3.0 and higher.
+ The status of the Software Retry mechanism.
+ Enabled when the Adaptive Modulation algorithm is enabled and
+ the Burst Mode Option is disabled. Otherwise it is disabled."
+ ::= { bwaVLAdaptiveModulationParams 2 }
+
+
+ bwaVLNumOfSoftwareRetries OBJECT-TYPE
+ SYNTAX INTEGER { na (255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Read-only for units with version 2.0.
+ Not applicable for units with SW version 3.0 and higher.
+ The maximum number of times to use the Software Retry mechanism
+ when it is enabled."
+ ::= { bwaVLAdaptiveModulationParams 3 }
+
+
+
+ bwaVLMinIntervalBetweenAdaptiveModulationAlgorithmMessages OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable all units.
+ The minimum interval between two consecutive AU/BU to SU/RB messages.
+ Range: 1 to 3600 (Sec)."
+ ::= { bwaVLAdaptiveModulationParams 4 }
+
+ bwaVLAdaptiveModulationDecisionThresholds OBJECT-TYPE
+ SYNTAX INTEGER { normal (1) , high (2), na (255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Defines the setting of thresholds for the rate decision algorithm.
+ high (2) should typically be used when the SNR is lower than 13dB."
+ ::= { bwaVLAdaptiveModulationParams 5 }
+
+bwaVLBurstMode OBJECT IDENTIFIER ::= {bwaVLPerformanceParams 10}
+
+ bwaVLBurstModeOption OBJECT-TYPE
+ SYNTAX INTEGER { disable (1) , enable (2), blocked(3), na (255) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Applicable only if Burst Mode Option is supported by country
+ specific parameters of the Sub Band.
+ Not applicable if Wireless Link Prioritization is enabled.
+ Enables/disable burst mode operation.
+ In SU/RB with HW Revision B or lower blocked(3) value is returned
+ when Security Mode is Wep , Data Encryption Option
+ is Enabled and Burst option is Enabled.
+ In AU/BU with HW Revision B or lower blocked(3) value is returned
+ when Dfs Option is Enabled and Burst mode is enabled."
+ ::= { bwaVLBurstMode 1 }
+
+ bwaVLBurstInterval OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Not applicable if Wireless Link Prioritization is enabled.
+ Burst mode interval in milliseconds.
+ Range: 1 to the maximum value as defined in the country
+ specific parameters of the Sub Band (milliseconds)."
+ ::= { bwaVLBurstMode 2 }
+
+bwaVLConcatenationParameters OBJECT IDENTIFIER ::= {bwaVLPerformanceParams 11}
+
+ bwaVLConcatenationOption OBJECT-TYPE
+ SYNTAX INTEGER { disable (1), enable (2), na (255)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Defines the Concatenation option."
+ ::= { bwaVLConcatenationParameters 1 }
+
+ bwaVLConcatenationMaximumNumberOfFrames OBJECT-TYPE
+ SYNTAX INTEGER (2..8)
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units with SW version 3.X .
+ Not applicable for version 4.0 and higher.
+ Defines the maximum numbers of frames that can be concatenated.
+ Range:2 to 8 (frames)."
+ ::= { bwaVLConcatenationParameters 2 }
+
+ bwaVLConcatenationMaxFrameSize OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Defines the maximum size of a concatenated frame.
+ Range:
+ 256 to 2200 (bytes) for BWA PtP products BU/RB14 BU/RB28,
+ or for AU/SU with HW revision A or B.
+ 256 to 4032 (bytes) for AU/SU with HW Revision
+ C or higher and BWA PtP products BU/RB100."
+ ::= { bwaVLConcatenationParameters 3 }
+
+
+-- Site Survey Params
+-- ==================
+bwaVLSiteSurvey OBJECT IDENTIFIER ::= {bwaVLMib 11}
+
+ bwaVLAverageReceiveSNR OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB only.
+ The average Signal to Noise Ratio of received frames."
+ ::= { bwaVLSiteSurvey 1 }
+
+-- Traffic Counters
+-- ================
+bwaVLTrafficStatistics OBJECT IDENTIFIER ::= {bwaVLSiteSurvey 2}
+
+
+ bwaVLResetTrafficCounters OBJECT-TYPE
+ SYNTAX INTEGER { reset (1),cancel(2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Resets the traffic counters."
+ ::= { bwaVLTrafficStatistics 1 }
+
+bwaVLEthCounters OBJECT IDENTIFIER ::= {bwaVLTrafficStatistics 2}
+bwaVLWirelessLinkCounters OBJECT IDENTIFIER ::= {bwaVLTrafficStatistics 3}
+bwaVLWirelessLinkEvents OBJECT IDENTIFIER ::= {bwaVLTrafficStatistics 4}
+
+bwaVLPerModulationLevelCounters OBJECT IDENTIFIER ::= {bwaVLTrafficStatistics 5}
+
+
+ bwaVLResetPerModulationLevelCounters OBJECT-TYPE
+ SYNTAX INTEGER { resetCounters(1) , cancel (2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Resets the per-Modulation Level counters ."
+ ::= { bwaVLPerModulationLevelCounters 1 }
+
+
+
+ bwaVLSUPerModulationLevelCountersTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BwaVLSUPerModulationLevelCountersEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB.
+ Per Rate Counters table."
+ ::= { bwaVLPerModulationLevelCounters 2 }
+
+ bwaVLSUPerModulationLevelCountersEntry OBJECT-TYPE
+ SYNTAX BwaVLSUPerModulationLevelCountersEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB.
+ An entry in the Per modulation Counters table."
+ INDEX { bwaVLSUPerModulationLevelCountersTableIdx }
+ ::= { bwaVLSUPerModulationLevelCountersTable 1 }
+
+ BwaVLSUPerModulationLevelCountersEntry ::= SEQUENCE {
+ bwaVLSUPerModulationLevelCountersTableIdx INTEGER,
+ bwaVLSUPerModulationLevelCountersApplicableModLevel INTEGER,
+ bwaVLSUPerModulationLevelCountersTxSuccess Counter32,
+ bwaVLSUPerModulationLevelCountersTxFailed Counter32
+ }
+
+
+ bwaVLSUPerModulationLevelCountersTableIdx OBJECT-TYPE
+ SYNTAX INTEGER (1..8)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB.
+ An index of an entry in the Per modulation level Counters table."
+ ::= { bwaVLSUPerModulationLevelCountersEntry 1 }
+
+ bwaVLSUPerModulationLevelCountersApplicableModLevel OBJECT-TYPE
+ SYNTAX INTEGER {
+ modLevel-1 (1),
+ modLevel-2 (2),
+ modLevel-3 (3),
+ modLevel-4 (4),
+ modLevel-5 (5),
+ modLevel-6 (6),
+ modLevel-7 (7),
+ modLevel-8 (8)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB.
+ The applicable modulation level of the entry in the Per
+ modulation level Counters table.
+ Modulation Level 8 is not applicable for units with HW revision A."
+ ::= { bwaVLSUPerModulationLevelCountersEntry 2 }
+
+
+ bwaVLSUPerModulationLevelCountersTxSuccess OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB.
+ The total number of successfully transmitted unicasts at the
+ applicable modulation level."
+ ::= { bwaVLSUPerModulationLevelCountersEntry 3 }
+
+
+ bwaVLSUPerModulationLevelCountersTxFailed OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB.
+ The total number of dropped frames at the applicable
+ Modulation Level."
+ ::= { bwaVLSUPerModulationLevelCountersEntry 4 }
+
+
+ bwaVLAverageModulationLevel OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB.
+ The average modulation level for successful transmission
+ (rounded to nearest integer) since last reset of the
+ Per Modulation Level counters.
+ Range: 1 to 8."
+ ::= { bwaVLPerModulationLevelCounters 3 }
+
+ bwaVLTotalRxFramesViaEthernet OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Total number of frames received via the Ethernet port."
+ ::= { bwaVLEthCounters 1 }
+
+ bwaVLTxWirelessToEthernet OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Total number of frames transmitted to the Ethernet port."
+ ::= { bwaVLEthCounters 2 }
+
+bwaVLTxFramesToWireless OBJECT IDENTIFIER ::= {bwaVLWirelessLinkCounters 1}
+
+ bwaVLAUBeaconsToWireless OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ The number of beacons transmitted to the wireless media."
+ ::= { bwaVLTxFramesToWireless 1 }
+
+-- bwaVLOtherMngFramesToWireless OBJECT-TYPE
+-- SYNTAX Counter32
+-- MAX-ACCESS read-only
+-- STATUS current
+-- DESCRIPTION
+-- "Applicable to AU and SU.
+-- The number of management frames transmitted to the wireless media.
+-- In AU, this count does not include Beacons."
+-- ::= { bwaVLTxFramesToWireless 2 }
+
+ bwaVLDataAndOtherMngFramesToWireless OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ The number of data and management frames transmitted to the
+ wireless media. The count includes one count for each data
+ frame transmitted successfully (excluding retransmissions)."
+ ::= { bwaVLTxFramesToWireless 3 }
+
+ bwaVLTotalTxFramesToWireless OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The number of frames transmitted to the wireless media.
+ The count includes one count for each data frame
+ that was transmitted successfully (excluding retransmissions),
+ and also the number of transmitted control and management frames,
+ including beacons."
+ ::= { bwaVLTxFramesToWireless 4 }
+
+ bwaVLTotalTransmittedUnicasts OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ The total number of unicast frames successfully transmitted
+ to the wireless media, excluding retransmissions."
+ ::= { bwaVLTxFramesToWireless 5 }
+
+ bwaVLTotalTransmittedConcatenatedFramesDouble OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all products.
+ The total number of double concatenated frames successfully transmitted
+ to the wireless media, excluding retransmissions."
+ ::= { bwaVLTxFramesToWireless 6 }
+
+ bwaVLTotalTransmittedConcatenatedFramesSingle OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all products.
+ The total number of double concatenated frames successfully transmitted
+ to the wireless media, excluding retransmissions."
+ ::= { bwaVLTxFramesToWireless 7 }
+
+ bwaVLTotalTransmittedConcatenatedFramesMore OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all products.
+ The total number of concatenated frames with more then two frames successfully
+ transmitted to the wireless media, excluding retransmissions."
+ ::= { bwaVLTxFramesToWireless 8 }
+
+ bwaVLTotalRxFramesFromWireless OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The total number of frames that were received
+ from the wireless media.
+ The count includes data and control and management
+ frames, including beacons received from the AU/BU.
+ The count does not include frames that were discarded
+ internally, bad frames and duplicate frames."
+ ::= { bwaVLWirelessLinkCounters 2 }
+
+ bwaVLTotalRetransmittedFrames OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The total number of retransmissions of data frames
+ (counts all unsuccessful transmissions/retransmissions)."
+ ::= { bwaVLWirelessLinkCounters 3 }
+
+ bwaVLFramesDropped OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The number of dropped frames.
+ The frames that were retransmitted to the extent
+ of the maximum allowed number of retransmissions
+ without being acknowledged.."
+ ::= { bwaVLWirelessLinkCounters 4 }
+
+
+bwaVLDataFramesSubmittedToBridge OBJECT IDENTIFIER ::= {bwaVLWirelessLinkCounters 5}
+
+ bwaVLFramesSubmittedViaHighQueue OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Frames submitted to the internal bridge via the High priority queue.
+ for transmission to the wireless media."
+ ::= { bwaVLDataFramesSubmittedToBridge 1 }
+
+ bwaVLFramesSubmittedViaMidQueue OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Frames submitted to the internal bridge via the Mid priority queue
+ for transmission to the wireless media."
+ ::= { bwaVLDataFramesSubmittedToBridge 2 }
+
+ bwaVLFramesSubmittedViaLowQueue OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Frames submitted to the internal bridge via the Low priority queue
+ for transmission to the wireless media."
+ ::= { bwaVLDataFramesSubmittedToBridge 3 }
+
+ bwaVLTotalNoOfDataFramesSubmitted OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The total number of data frames submitted to the internal bridge
+ for transmission to the wireless media."
+ ::= { bwaVLDataFramesSubmittedToBridge 4 }
+
+
+ bwaVLTotalRecievedDataFrames OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The total number of data frames received from the
+ wireless media, including duplicate frames."
+ ::= { bwaVLWirelessLinkCounters 6 }
+
+ bwaVLRecievedBadFrames OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The number of frames received from the wireless
+ media with errors (CRC errors)."
+ ::= { bwaVLWirelessLinkCounters 7 }
+
+ bwaVLNoOfDuplicateFramesDiscarded OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The number of frames discarded due to receiving multiple copies."
+ ::= { bwaVLWirelessLinkCounters 8 }
+
+ bwaVLNoOfInternallyDiscardedMirCir OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The number of data frames received from the Ethernet port that were
+ discarded by the MIR/CIR mechanism either to avoid exceeding the
+ maximum allowed information rate, or when the wireless link conditions
+ do not enable reaching the allowed rate."
+ ::= { bwaVLWirelessLinkCounters 9 }
+
+ bwaVLTotalRxConcatenatedFramesDouble OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The total number of double concatenated frames received
+ from the wireless media, including duplicate frames."
+ ::= { bwaVLWirelessLinkCounters 10 }
+
+ bwaVLTotalRxConcatenatedFramesSingle OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The total number of data fast frames single concatenated
+ frames received from the wireless media, including duplicate frames."
+ ::= { bwaVLWirelessLinkCounters 11 }
+
+ bwaVLTotalRxConcatenatedFramesMore OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The total number of data fast frames concatenated with more then two
+ frames received from the wireless media, including duplicate frames."
+ ::= { bwaVLWirelessLinkCounters 12 }
+
+-- bwaVLInternallyGeneratedFramesSubmittedToBridge OBJECT-TYPE
+-- SYNTAX Counter32
+-- MAX-ACCESS read-only
+-- STATUS current
+-- DESCRIPTION
+-- "Applicable to SU and AU. Read-only.
+-- The number of internally generated frames(wireless management and control frames)
+-- submitted to the bridge for transmission to the wireless media."
+-- ::= { bwaVLWirelessLinkCounters 10 }
+
+
+bwaVLTxEvents OBJECT IDENTIFIER ::= {bwaVLWirelessLinkEvents 1}
+
+ bwaVLDroppedFrameEvents OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The number of frames that were dropped because they were retransmitted
+ to the maximum allowed number of retransmissions without being
+ acknowledged."
+ ::= { bwaVLTxEvents 1 }
+
+ bwaVLFramesDelayedDueToSwRetry OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Not applicable for units with SW Version 3.0 and higher.
+ The number of frames that were delayed because the SW retry
+ algorithm was activated on a previous frame designated for the
+ same recipient."
+ ::= { bwaVLTxEvents 2 }
+
+ bwaVLUnderrunEvents OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The number of frames whose transmission was aborted because the rate
+ of submitting frames for transmission exceeded the available
+ transmission capability."
+ ::= { bwaVLTxEvents 3 }
+
+ bwaVLOthersTxEvents OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The number of Tx events due to problems other than those of
+ the other Tx Events counters."
+ ::= { bwaVLTxEvents 4 }
+
+ bwaVLTotalTxEvents OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The total number of Tx special events."
+ ::= { bwaVLTxEvents 5 }
+
+bwaVLRxEvents OBJECT IDENTIFIER ::= {bwaVLWirelessLinkEvents 2}
+
+ bwaVLPhyErrors OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units, only when DFS is enabled.
+ The number of unidentified signals."
+ ::= { bwaVLRxEvents 1 }
+
+ bwaVLCRCErrors OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The number of frames received from the wireless media containing
+ CRC errors."
+ ::= { bwaVLRxEvents 2 }
+
+ bwaVLOverrunEvents OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The number of frames that were discarded because the receive
+ rate exceeded the processing capability or the capacity of the
+ Ethernet port."
+ ::= { bwaVLRxEvents 3 }
+
+ bwaVLRxDecryptEvents OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The number of frames that were not received properly due to a
+ problem in the data decryption mechanism."
+ ::= { bwaVLRxEvents 4 }
+
+ bwaVLTotalRxEvents OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The total number of Rx special events."
+ ::= { bwaVLRxEvents 5 }
+
+
+-- Associations Database
+--
+bwaVLMacAddressDatabase OBJECT IDENTIFIER ::= {bwaVLSiteSurvey 5}
+
+bwaVLAUMacAddressDatabase OBJECT IDENTIFIER ::= {bwaVLMacAddressDatabase 1}
+
+bwaVLAUAdbResetAllModulationLevelCounters OBJECT-TYPE
+ SYNTAX INTEGER { reset (1), cancel (2) }
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ To reset all the counters for all SUs/RB in the MAC Address Database."
+ ::= { bwaVLAUMacAddressDatabase 1 }
+
+bwaVLAUAdbTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BwaVLAUAdbEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ AU/BU MAC Address Database table."
+ ::= { bwaVLAUMacAddressDatabase 2 }
+
+bwaVLAUAdbEntry OBJECT-TYPE
+ SYNTAX BwaVLAUAdbEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ An entry in the AU/BU MAC Address Database table."
+ INDEX { bwaVLAdbIndex }
+ ::= { bwaVLAUAdbTable 1 }
+
+
+BwaVLAUAdbEntry ::= SEQUENCE {
+ bwaVLAdbIndex INTEGER,
+ bwaVLAdbMacAddress MacAddress,
+ bwaVLAdbStatus INTEGER,
+ bwaVLAdbSwVersion DisplayString,
+ bwaVLAdbSNR INTEGER,
+ bwaVLAdbMaxModulationLevel INTEGER,
+ bwaVLAdbTxFramesTotal Counter32,
+ bwaVLAdbDroppedFramesTotal Counter32,
+ bwaVLAdbTxSuccessModLevel1 Counter32,
+ bwaVLAdbTxSuccessModLevel2 Counter32,
+ bwaVLAdbTxSuccessModLevel3 Counter32,
+ bwaVLAdbTxSuccessModLevel4 Counter32,
+ bwaVLAdbTxSuccessModLevel5 Counter32,
+ bwaVLAdbTxSuccessModLevel6 Counter32,
+ bwaVLAdbTxSuccessModLevel7 Counter32,
+ bwaVLAdbTxSuccessModLevel8 Counter32,
+ bwaVLAdbTxFailedModLevel1 Counter32,
+ bwaVLAdbTxFailedModLevel2 Counter32,
+ bwaVLAdbTxFailedModLevel3 Counter32,
+ bwaVLAdbTxFailedModLevel4 Counter32,
+ bwaVLAdbTxFailedModLevel5 Counter32,
+ bwaVLAdbTxFailedModLevel6 Counter32,
+ bwaVLAdbTxFailedModLevel7 Counter32,
+ bwaVLAdbTxFailedModLevel8 Counter32,
+ bwaVLAdbCirTx INTEGER,
+ bwaVLAdbMirTx INTEGER,
+ bwaVLAdbCirRx INTEGER,
+ bwaVLAdbMirRx INTEGER,
+ bwaVLAdbCirMaxDelay INTEGER,
+ bwaVLAdbDistance INTEGER,
+ bwaVLAdbHwRevision INTEGER,
+ bwaVLAdbCpldVer DisplayString,
+ bwaVLAdbCountryCode INTEGER,
+ bwaVLAdbBootVer DisplayString,
+ bwaVLAdbAtpcOption INTEGER,
+ bwaVLAdbAdapModOption INTEGER,
+ bwaVLAdbBurstModeOption INTEGER,
+ bwaVLAdbConcatenationOption INTEGER,
+ bwaVLAdbSecurityMode INTEGER,
+ bwaVLAdbAuthOption INTEGER,
+ bwaVLAdbDataEncyptOption INTEGER,
+ bwaVLAdbAge INTEGER,
+ bwaVLAdbUnitName DisplayString
+ }
+
+bwaVLAdbIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..512)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ The index of an entry in the AU/BU MAC Address Database table."
+ ::= { bwaVLAUAdbEntry 1 }
+
+bwaVLAdbMacAddress OBJECT-TYPE
+ SYNTAX MacAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ The MAC Address of an SU/RB entry in the MAC Address Database
+ table."
+ ::= { bwaVLAUAdbEntry 2 }
+
+bwaVLAdbStatus OBJECT-TYPE
+ SYNTAX INTEGER { associated (1),
+ authenticated (2),
+ notAuthenticated (3) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ The status of the relevant SU/RB."
+ ::= { bwaVLAUAdbEntry 3 }
+
+bwaVLAdbSwVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ The SW version of the relevant SU/RB."
+ ::= { bwaVLAUAdbEntry 4 }
+
+bwaVLAdbSNR OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ The average Signal to Noise Ratio in dB of frames received by
+ the AU/BU from the relevant SU/RB."
+ ::= { bwaVLAUAdbEntry 5 }
+
+bwaVLAdbMaxModulationLevel OBJECT-TYPE
+ SYNTAX INTEGER { modLevel-1 (1),
+ modLevel-2 (2),
+ modLevel-3 (3),
+ modLevel-4 (4),
+ modLevel-5 (5),
+ modLevel-6 (6),
+ modLevel-7 (7),
+ modLevel-8 (8)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ The value configured in the relevant SU/RB for the Maximum Modulation
+ Level parameter.
+ Modulation Level 8 is not applicable for units with HW revision A."
+ ::= { bwaVLAUAdbEntry 6 }
+
+bwaVLAdbTxFramesTotal OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Counts the total number of unicast frames (excluding retransmissions)
+ that were successfully transmitted to the SU/RB over the wireless link."
+ ::= { bwaVLAUAdbEntry 7 }
+
+bwaVLAdbDroppedFramesTotal OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Counts the total number of frames intended to the SU/RB that
+ were dropped because they were retransmitted to the extent
+ of the maximum allowed number of retransmissions without
+ being acknowledged."
+ ::= { bwaVLAUAdbEntry 8 }
+
+bwaVLAdbTxSuccessModLevel1 OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Counts the total number of unicast frames (excluding retransmissions)
+ that were successfully transmitted to the SU/RB over the wireless link
+ using modulation level 1."
+ ::= { bwaVLAUAdbEntry 9 }
+
+bwaVLAdbTxSuccessModLevel2 OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Counts the total number of unicast frames (excluding retransmissions)
+ that were successfully transmitted to the SU/RB over the wireless link
+ using modulation level 2."
+ ::= { bwaVLAUAdbEntry 10 }
+
+bwaVLAdbTxSuccessModLevel3 OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Counts the total number of unicast frames (excluding retransmissions)
+ that were successfully transmitted to the SU/BU over the wireless link
+ using modulation level 3."
+ ::= { bwaVLAUAdbEntry 11 }
+
+bwaVLAdbTxSuccessModLevel4 OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Counts the total number of unicast frames (excluding retransmissions)
+ that were successfully transmitted to the SU/RB over the wireless link
+ using modulation level 4."
+ ::= { bwaVLAUAdbEntry 12 }
+
+bwaVLAdbTxSuccessModLevel5 OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Counts the total number of unicast frames (excluding retransmissions)
+ that were successfully transmitted to the SU/RB over the wireless link
+ using modulation level 5."
+ ::= { bwaVLAUAdbEntry 13 }
+
+bwaVLAdbTxSuccessModLevel6 OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Counts the total number of unicast frames (excluding retransmissions)
+ that were successfully transmitted to the SU/BU over the wireless link
+ using modulation level 6."
+ ::= { bwaVLAUAdbEntry 14 }
+
+bwaVLAdbTxSuccessModLevel7 OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Counts the total number of unicast frames (excluding retransmissions)
+ that were successfully transmitted to the SU/RB over the wireless link
+ using modulation level 7."
+ ::= { bwaVLAUAdbEntry 15 }
+
+bwaVLAdbTxSuccessModLevel8 OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Counts the total number of unicast frames (excluding retransmissions)
+ that were successfully transmitted to the SU/RB over the wireless link
+ using modulation level 8.
+ Not applicable for units with HW revision A."
+ ::= { bwaVLAUAdbEntry 16 }
+
+bwaVLAdbTxFailedModLevel1 OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Counts the total number of failures to successfully
+ transmit unicast frames intended to the SU/RB using modulation level 1."
+ ::= { bwaVLAUAdbEntry 17 }
+
+bwaVLAdbTxFailedModLevel2 OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Counts the total number of failures to successfully
+ transmit unicast frames intended to the SU/RB using modulation level 2."
+ ::= { bwaVLAUAdbEntry 18 }
+
+bwaVLAdbTxFailedModLevel3 OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Counts the total number of failures to successfully
+ transmit unicast frames intended to the SU/RB using modulation level 3."
+ ::= { bwaVLAUAdbEntry 19 }
+
+bwaVLAdbTxFailedModLevel4 OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Counts the total number of failures to successfully
+ transmit unicast frames intended to the SU/RB using modulation level 4."
+ ::= { bwaVLAUAdbEntry 20 }
+
+bwaVLAdbTxFailedModLevel5 OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Counts the total number of failures to successfully
+ transmit unicast frames intended to the SU/RB using modulation level 5."
+ ::= { bwaVLAUAdbEntry 21 }
+
+bwaVLAdbTxFailedModLevel6 OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Counts the total number of failures to successfully
+ transmit unicast frames intended to the SU/RB using modulation level 6."
+ ::= { bwaVLAUAdbEntry 22 }
+
+bwaVLAdbTxFailedModLevel7 OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Counts the total number of failures to successfully
+ transmit unicast frames intended to the SU/RB using modulation level 7."
+ ::= { bwaVLAUAdbEntry 23 }
+
+bwaVLAdbTxFailedModLevel8 OBJECT-TYPE
+ SYNTAX Counter32
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Counts the total number of failures to successfully
+ transmit unicast frames intended to the SU/RB using modulation level 8.
+ Not applicable for units with HW revision A."
+ ::= { bwaVLAUAdbEntry 24 }
+
+bwaVLAdbCirTx OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU Only.
+ Not applicable to BWA-PtP products. Read-only.
+ The value configured in the relevant SU for the CIR:
+ SU to AU parameter."
+ ::= { bwaVLAUAdbEntry 25 }
+
+bwaVLAdbMirTx OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ The value configured in the relevant SU/RB for the MIR:
+ SU/RB to AU/BU parameter."
+ ::= { bwaVLAUAdbEntry 26 }
+
+bwaVLAdbCirRx OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU Only.
+ Not applicable to BWA-PtP products.
+ The value configured in the relevant SU for the CIR:
+ AU to SU parameter."
+ ::= { bwaVLAUAdbEntry 27 }
+
+bwaVLAdbMirRx OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ The value configured in the relevant SU/RB for the MIR:
+ AU/BU to SU/RB parameter."
+ ::= { bwaVLAUAdbEntry 28 }
+
+bwaVLAdbCirMaxDelay OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU Only.
+ Not applicable to BWA-PtP products.
+ The value configured in the relevant SU for the CIR Maximum
+ Delay parameter."
+ ::= { bwaVLAUAdbEntry 29 }
+
+bwaVLAdbDistance OBJECT-TYPE
+ SYNTAX INTEGER {below-2-Km(1)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU Only.
+ The distance between the SU/RB and the AU/BU (In Kilometers)."
+ ::= { bwaVLAUAdbEntry 30 }
+
+bwaVLAdbHwRevision OBJECT-TYPE
+ SYNTAX INTEGER {hwRevisionA(1), hwRevisionB(2), hwRevisionC(3),
+ hwRevisionD(4), hwRevisionE(5), na(255)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU Only.
+ The SU/RB HW Revision."
+ ::= { bwaVLAUAdbEntry 31 }
+
+bwaVLAdbCpldVer OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU Only.
+ The SU/RB CPLD Version."
+ ::= { bwaVLAUAdbEntry 32 }
+
+bwaVLAdbCountryCode OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU Only.
+ The SU/RB supported country code."
+ ::= { bwaVLAUAdbEntry 33 }
+
+bwaVLAdbBootVer OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU Only.
+ The SU/RB Boot Version."
+ ::= { bwaVLAUAdbEntry 34 }
+
+bwaVLAdbAtpcOption OBJECT-TYPE
+ SYNTAX INTEGER {disable (1), enable (2), na (255)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU Only.
+ The SU/RB ATPC option configuration."
+ ::= { bwaVLAUAdbEntry 35 }
+
+bwaVLAdbAdapModOption OBJECT-TYPE
+ SYNTAX INTEGER {disable (1), enable (2), na (255)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU Only.
+ The SU/RB adaptive modulation option configuration."
+ ::= { bwaVLAUAdbEntry 36 }
+
+bwaVLAdbBurstModeOption OBJECT-TYPE
+ SYNTAX INTEGER {disable (1), enable (2), na (255)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU Only.
+ The SU/RB burst mode option configuration."
+ ::= { bwaVLAUAdbEntry 37 }
+
+bwaVLAdbConcatenationOption OBJECT-TYPE
+ SYNTAX INTEGER {disable (1), enable (2), na(255)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU Only.
+ The SU/RB concatenation option configuration."
+ ::= { bwaVLAUAdbEntry 39 }
+
+bwaVLAdbSecurityMode OBJECT-TYPE
+ SYNTAX INTEGER {wep(1), aes(2), fips197(3), na(255)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU Only.
+ The SU/RB security mode configuration."
+ ::= { bwaVLAUAdbEntry 41 }
+
+bwaVLAdbAuthOption OBJECT-TYPE
+ SYNTAX INTEGER {openSystem (1), sharedKey (2), na (255)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU Only.
+ The SU/RB authentication algorithm configuration."
+ ::= { bwaVLAUAdbEntry 42 }
+
+bwaVLAdbDataEncyptOption OBJECT-TYPE
+ SYNTAX INTEGER {disable (1), enable (2), na (255)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU Only.
+ The SU/RB data encryption option configuration."
+ ::= { bwaVLAUAdbEntry 43 }
+
+bwaVLAdbAge OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ The time since any packet was received from the relevant SU/RB."
+ ::= { bwaVLAUAdbEntry 44 }
+
+bwaVLAdbUnitName OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ The unit name of the relevant SU/RB."
+ ::= { bwaVLAUAdbEntry 45 }
+
+bwaVLUpLinkQualityIndicator OBJECT IDENTIFIER ::= { bwaVLSiteSurvey 6}
+
+bwaVLMeasureUpLinkQualityIndicator OBJECT-TYPE
+ SYNTAX INTEGER { start (1) , cancel (2)}
+ MAX-ACCESS read-write
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB.
+ Starts calculation of LQI.
+ The calculation will be for a period of 10 seconds."
+ ::= { bwaVLUpLinkQualityIndicator 1 }
+
+
+bwaVLReadUpLinkQualityIndicator OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB.
+ The results of the last LQI calculation.
+ Range: 1 to 8."
+ ::= { bwaVLUpLinkQualityIndicator 2 }
+
+
+bwaVLUpLinkQualityIndicatorStatus OBJECT-TYPE
+ SYNTAX INTEGER {fullTest(1) , limitedTest(2)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to SU/RB Only.
+ Indicates the test conditions.
+ fullTest means that there are no limitations
+ on the range of available modulation levels, and that all modulation levels
+ from 1 to 8 can be used.
+ limitedTest indicates that the results may not indicate the true quality since
+ the available range is limited - by HW (HW Revision A),
+ or by the applicable parameters in the country code,
+ or by the configurable Maximum Modulation Level parameter."
+ ::= { bwaVLUpLinkQualityIndicator 3 }
+
+-- AC pinpoint table end
+
+bwaVLMacPinpoint OBJECT IDENTIFIER ::= {bwaVLSiteSurvey 7}
+
+ bwaVLMacPinpointTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BwaVLMacPinpointEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ A table that contains information about wireless device
+ used by a certain Ethernet station in order to
+ connect to the wireless network"
+ ::= { bwaVLMacPinpoint 1 }
+
+ bwaVLMacPinpointEntry OBJECT-TYPE
+ SYNTAX BwaVLMacPinpointEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only. An entry in the MAC Pinpoint Table.
+ Each entry contains an Ethernet station MAC address and the MAC
+ address of the wireless device used to connect it to the wireless
+ network"
+ INDEX { mptEthernetStationMACAddress }
+ ::= { bwaVLMacPinpointTable 1 }
+
+ BwaVLMacPinpointEntry ::=
+ SEQUENCE {
+ mptEthernetStationMACAddress
+ MacAddress,
+ mptUnitMACAddress
+ MacAddress
+ }
+
+ mptEthernetStationMACAddress OBJECT-TYPE
+ SYNTAX MacAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ The MAC address of the Ethernet station. It is used as an
+ index in the MAC Pinpoint Table."
+ ::= { bwaVLMacPinpointEntry 1 }
+
+ mptUnitMACAddress OBJECT-TYPE
+ SYNTAX MacAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only. The MAC address of the wireless
+ device used by the station with the MAC Address from the
+ index in order to access the wireless network."
+ ::= { bwaVLMacPinpointEntry 2 }
+-- AC pinpoint table end
+
+-- GATEWAY TABLE BEGIN
+
+bwaVLDrapGatewaysTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF BwaVLDrapGatewayEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "This table provides information about Gateways supporting DRAP that are
+ registered at the AU"
+ ::= { bwaVLSiteSurvey 8 }
+
+bwaVLDrapGatewayEntry OBJECT-TYPE
+ SYNTAX BwaVLDrapGatewayEntry
+ MAX-ACCESS not-accessible
+ STATUS current
+ DESCRIPTION
+ "A Drap Gateway Entry."
+ INDEX { bwaVLDrapGatewayIndex }
+ ::= { bwaVLDrapGatewaysTable 1 }
+
+BwaVLDrapGatewayEntry ::= SEQUENCE {
+ bwaVLDrapGatewayIndex INTEGER,
+ bwaVLDrapGatewayIP IpAddress,
+ bwaVLDrapGatewayType INTEGER,
+ bwaVLDrapGatewayNoOfActiveVoiceCalls INTEGER
+ }
+
+bwaVLDrapGatewayIndex OBJECT-TYPE
+ SYNTAX INTEGER (1..512)
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Gateway Entry's Index"
+ ::= { bwaVLDrapGatewayEntry 1 }
+
+bwaVLDrapGatewayIP OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The IP address of the Gateway"
+ ::= { bwaVLDrapGatewayEntry 2 }
+
+bwaVLDrapGatewayType OBJECT-TYPE
+ SYNTAX INTEGER { vgDataVoice (4), vgData1Voice1 (5),
+ vgData4Voice2 (6), vgDataVoice2(7),
+ ngData4Wireless (11),
+ vgUnknown(255)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The Gateway type"
+ ::= { bwaVLDrapGatewayEntry 3 }
+
+bwaVLDrapGatewayNoOfActiveVoiceCalls OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The current number of active voice calls handled by the Gateway"
+ ::= { bwaVLDrapGatewayEntry 4 }
+
+-- GATEWAY TABLE END
+
+-- ****************************************************************************************
+-- TRAP defenitions:
+-- ****************************************************************************************
+
+bwaVLTraps OBJECT IDENTIFIER ::= { bwaVLMib 14 }
+
+bwaVLTrapSUMacAddr OBJECT-TYPE
+ SYNTAX MacAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ SU/RB MAC Address."
+ ::= { bwaVLTraps 1 }
+
+--bwaVLTrapSNRQuality OBJECT-TYPE
+-- SYNTAX INTEGER
+-- MAX-ACCESS read-only
+-- STATUS current
+-- DESCRIPTION
+-- "Applicable to SU only.
+-- SNR of received signal."
+-- ::= { bwaVLTraps 2 }
+
+bwaVLTrapText OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Textual string for future use."
+ ::= { bwaVLTraps 3 }
+
+bwaVLTrapToggle OBJECT-TYPE
+ SYNTAX INTEGER{
+ on (1),
+ off (2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ An On/Off toggle status."
+ ::= { bwaVLTraps 4 }
+
+bwaVLTrapParameterChanged OBJECT-TYPE
+ SYNTAX INTEGER{ cirOrMir (1),
+ ipFilter (2),
+ vlan (4)}
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ A modification to one of the parameters related to CIR/MIR,
+ IP Filtering or VLAN."
+ ::= { bwaVLTraps 5 }
+
+bwaVLTrapAccessRights OBJECT-TYPE
+ SYNTAX INTEGER{ notLoggedIn (1),
+ readOnly (2),
+ installer (3),
+ administrator (4),
+ factory (5) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The access rights used for login."
+ ::= { bwaVLTraps 6 }
+
+bwaVLTrapLog OBJECT-TYPE
+ SYNTAX INTEGER{ telnetLogin (3),
+ telnetLogout (4) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ Login or logout to the Monitor program via Telnet."
+ ::= { bwaVLTraps 7 }
+
+bwaVLTrapTelnetUserIpAddress OBJECT-TYPE
+ SYNTAX IpAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The IP address of a Telnet user."
+ ::= { bwaVLTraps 8 }
+
+bwaVLTrapRTx OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ Retransmissions as a percentage of total transmissions."
+ ::= { bwaVLTraps 9 }
+
+bwaVLTrapFtpOrTftpStatus OBJECT-TYPE
+ SYNTAX INTEGER{
+ successful (1),
+ failed (2)
+ }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The status of the last FTP/TFTP loading procedure."
+ ::= { bwaVLTraps 10 }
+
+bwaVLDFSMoveFreq OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU with HW revision B and lower
+ (for units with HW revision C and higher replaced by
+ bwaVLTrapDFSMoveFreq New to support a resolution of 0.5 MHz).
+ The new frequency in MHz after detecting radar on a previous channel."
+ ::= { bwaVLTraps 11 }
+
+bwaVLDFSMoveFreqNew OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU.
+ The new frequency in MHz after detecting radar on a previous channel.
+ (Replaces bwaVLDFSMoveFreq to support a resolution of 0.5 MHz for
+ units with HW revision C and higher)."
+ ::= { bwaVLTraps 12 }
+
+
+bwaVLEthBroadcastThresholdExceeded OBJECT-TYPE
+ SYNTAX INTEGER
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ The number of packets that are dropped by the ethernet broadcast/multicast limiter."
+ ::= { bwaVLTraps 13 }
+
+
+bwaVLTrapSubscriberType OBJECT-TYPE
+ SYNTAX INTEGER{ unknownSubscriberType(0),
+ su-3(3) , su-6(6) , rb-14(14),
+ su-24(24), rb-28(28), su-54(54),
+ rb-100(100) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to AUS only.
+ The type of subscriber that was rejected by AUS"
+ ::= { bwaVLTraps 14 }
+
+
+bwaVLTrapMACAddress OBJECT-TYPE
+ SYNTAX MacAddress
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to BU/RB only.
+ The MAC address of the BWA PtP unit whose type has been changed"
+ ::= { bwaVLTraps 15 }
+
+bwaVLNewUnitTypeTrap OBJECT-TYPE
+ SYNTAX INTEGER { bu(1), rb(2) }
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "Applicable to BU/RB only.
+ The new type of the BWA PtP unit."
+ ::= { bwaVLTraps 16 }
+
+bwaVLTrapSWVersion OBJECT-TYPE
+ SYNTAX DisplayString
+ MAX-ACCESS read-only
+ STATUS current
+ DESCRIPTION
+ "The SW version of the SU that tries to associate
+ with a station that has Wireless Link Prioritization Enabled"
+ ::= { bwaVLTraps 17 }
+
+--
+-- Private Traps for BWA-PtMP
+--
+
+bwaVLSUassociatedAUTRAP NOTIFICATION-TYPE
+ OBJECTS
+ {
+ bwaVLTrapSUMacAddr -- SU MAC address
+ }
+ STATUS current
+ DESCRIPTION
+ "An AU/BU trap indicating a new association with an SU/RB."
+ ::= { bwaVLProducts 2 }
+
+bwaVLAUdisassociatedTRAP NOTIFICATION-TYPE
+ OBJECTS
+ {
+ bwaVLTrapSUMacAddr --Unit MAC address
+ }
+ STATUS current
+ DESCRIPTION
+ "An AU/BU trap indicating that an SU/RB has been disassociated
+ from the AU.
+ The AU/BU decides that an SU/RB has been disassociated from it and remove it
+ from the ADB after receiving from another AU/BU a SNAP frame with the SU/RB
+ MAC address.
+ The SNAP frame indicating a network topology change where the SU/RB has
+ associated with another AU/BU will be received if both AUs/BUs are
+ connected to the same Ethernet backbone."
+ ::= { bwaVLProducts 3 }
+
+bwaVLAUagingTRAP NOTIFICATION-TYPE
+ OBJECTS
+ {
+ bwaVLTrapSUMacAddr -- Unit MAC address
+ }
+ STATUS current
+ DESCRIPTION
+ "An AU/BU trap indicating that the unit association was aged out
+ and removed from the Association database following its failure
+ to acknowledge a specified number of consecutive frames."
+ ::= { bwaVLProducts 4 }
+
+bwaVLSUassociatedTRAP NOTIFICATION-TYPE
+ OBJECTS
+ {
+-- bwaVLLastAUMacAddress, Old AU mac address
+ bwaVLAssociatedAU -- New AU mac address
+-- bwaVLTrapLastSNRQuality, Average SNR with old AU
+ }
+ STATUS current
+ DESCRIPTION
+ "An SU/RB trap indicating association with an AU/BU.
+ In addition to the MAC address information of the AU/BU, the
+ trap also includes information on the average SNR of frames
+ received from the AU/BU."
+ ::= { bwaVLProducts 6 }
+
+bwaVLAUwirelessQualityTRAP NOTIFICATION-TYPE
+ OBJECTS
+ {
+ bwaVLTrapToggle,
+ bwaVLTrapRTx
+ }
+ STATUS current
+ DESCRIPTION
+ "An AU/BU trap, indicating that the quality of the wireless
+ link (retransmissions rate) has changed and dropped below (Off) or increased
+ above (On) a threshold , defined by the *bwaVLWirelessTrapThreshold.
+ The threshold for AU/BU is a percentage of retransmissions."
+ ::= { bwaVLProducts 20 }
+
+bwaVLPowerUpFromReset NOTIFICATION-TYPE
+ OBJECTS
+ {
+ bwaVLUnitMacAddress -- Unit MAC address
+ }
+ STATUS current
+ DESCRIPTION
+ "An AU/BU trap indicating power up after Reset."
+ ::= { bwaVLProducts 101 }
+
+bwaVLTelnetStatusTRAP NOTIFICATION-TYPE
+ OBJECTS
+ {
+ bwaVLTrapLog,
+ bwaVLTrapAccessRights,
+ bwaVLTrapTelnetUserIpAddress
+ }
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ A trap indicating that a log-in or log-out has been performed
+ via Telnet. Includes the log-in access
+ right and the IP address of the PC performing Telnet."
+ ::= { bwaVLProducts 102 }
+
+bwaVLParameterChangedTRAP NOTIFICATION-TYPE
+ OBJECTS
+ {
+ bwaVLTrapParameterChanged
+ }
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. A trap indicating a change in a CIR/MIR, IP Filter
+ or VLAN parameter."
+ ::= { bwaVLProducts 103 }
+
+bwaVLLoadingStatusTRAP NOTIFICATION-TYPE
+ OBJECTS
+ {
+ bwaVLTrapFtpOrTftpStatus,
+ bwaVLUnitMacAddress
+ }
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units.
+ A trap indicating that last FTP/TFTP loading process has been
+ finished successfully or failed. "
+ ::= { bwaVLProducts 104 }
+
+bwaVLPromiscuousModeTRAP NOTIFICATION-TYPE
+ OBJECTS
+ {
+ bwaVLTrapToggle,
+ bwaVLUnitMacAddress
+ }
+ STATUS current
+ DESCRIPTION
+ "An AU/BU trap, indicating that the AU/BU In (On) Promiscuous Mode or
+ out (Off) Promiscuous Mode."
+ ::= { bwaVLProducts 105 }
+
+bwaVLDFSRadarDetecetedTRAP NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "DFS: Applicable to AU/BU only.
+ A trap indicating that a radar was detected. "
+ ::= { bwaVLProducts 106 }
+
+bwaVLDFSFrequcnyTRAP NOTIFICATION-TYPE
+ OBJECTS
+ {
+ bwaVLDFSMoveFreq,
+ bwaVLDFSMoveFreqNew
+ }
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ A trap indicating that the unit moved to a new frequency. "
+ ::= { bwaVLProducts 107 }
+
+bwaVLDFSNoFreeChannelsExistsTRAP NOTIFICATION-TYPE
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ A trap indicating that a radar was detected and there is no
+ free channel. "
+ ::= { bwaVLProducts 108 }
+
+bwaVLEthBroadcastMulticatLimiterTRAP NOTIFICATION-TYPE
+ OBJECTS
+ {
+ bwaVLEthBroadcastThresholdExceeded
+ }
+ STATUS current
+ DESCRIPTION
+ "Applicable to all units. The trap is send if the
+ ethernet broadcast filter threshold is exceeded
+ and it contains the number of dropped packets."
+ ::= { bwaVLProducts 109 }
+
+bwaVLAUSUnsupportedSubscriberTypeTRAP NOTIFICATION-TYPE
+ OBJECTS
+ {
+ bwaVLTrapSUMacAddr,
+ bwaVLTrapSubscriberType
+ }
+ STATUS current
+ DESCRIPTION
+ "Applicable to AUS only.
+ This trap is generated when a subscriber with unsupported type tries to associate to AUS.
+ The AUS supports only SU-3 and SU-6.
+ The first variable of the trap is the subscriber MAC Address.
+ The second variable is the type of subscriber"
+ ::= { bwaVLProducts 110 }
+
+
+bwaVLUnitTypeChangedTRAP NOTIFICATION-TYPE
+ OBJECTS
+ {
+ bwaVLTrapMACAddress,
+ bwaVLNewUnitTypeTrap
+ }
+ STATUS current
+ DESCRIPTION
+ "Applicable to BU/RB only.
+ This trap is generated when the user change the type of the BWA PtP unit.
+ The RB can be converted in BU or vice versa.
+ The first variable of the trap is the unit MAC Address.
+ The second variable is the new type of the unit"
+ ::= { bwaVLProducts 111 }
+
+bwaVLWLPrioritizationNotSupportedBySUTRAP NOTIFICATION-TYPE
+ OBJECTS
+ {
+ bwaVLTrapSUMacAddr,
+ bwaVLTrapSWVersion
+ }
+ STATUS current
+ DESCRIPTION
+ "Applicable to AU/BU only.
+ This trap is generated when an SU/RB with a SW version below 4.0
+ that does not support Wireless Link Prioritization is associated
+ with an AU/BU with thw Wireless Link Prioritization Option enabled.
+ The first variable of the trap is the SU/RB MAC Address.
+ The second variable is the SW version of the SU/RB"
+ ::= { bwaVLProducts 112 }
+
+END
diff --git a/tests/OSDiscoveryTest.php b/tests/OSDiscoveryTest.php
index 4b4130a6ac..3b0b768d24 100644
--- a/tests/OSDiscoveryTest.php
+++ b/tests/OSDiscoveryTest.php
@@ -358,6 +358,11 @@ class DiscoveryTest extends \PHPUnit_Framework_TestCase
$this->checkOS('bnt', 'bnt1');
}
+ public function testBreeze()
+ {
+ $this->checkOS('breeze');
+ }
+
public function testBrother()
{
$this->checkOS('brother');
diff --git a/tests/snmpsim/breeze.snmprec b/tests/snmpsim/breeze.snmprec
new file mode 100644
index 0000000000..99657e0cb0
--- /dev/null
+++ b/tests/snmpsim/breeze.snmprec
@@ -0,0 +1,2 @@
+1.3.6.1.2.1.1.1.0|4|Alvarion - BreezeNet B , Version: 4.0.24 (Date: Jul 03 2006, 15:31:42)
+1.3.6.1.2.1.1.2.0|6|1.3.6.1.4.1.12394.4.1.33