mirror of
https://github.com/librenms/librenms.git
synced 2024-09-21 10:28:13 +00:00
MegaRaid controller in Linux (Broadcom/LSI) (#12999)
* Add power consumed
* Revert "Add power consumed"
This reverts commit 424554ac04bd340de2fd962cb6808045024ef783.
* Start with tempsensorts aus some states
* Inventory data
* Convert plugins to Blade
* Revert "Convert plugins to Blade"
This reverts commit 8d1d3ff5b1
.
* fix style
* Add FANs and Powersupplies
* fix style
* add test data
* add a short description for the doc
* refresh Testfile
This commit is contained in:
parent
1084bd6d1a
commit
c984cdbebc
@ -105,6 +105,7 @@ by following the steps under the `SNMP Extend` heading.
|
||||
1. [Mailcow-dockerized postfix](#mailcow-dockerized-postfix) - SNMP extend
|
||||
1. [Mailscanner](#mailscanner) - SNMP extend
|
||||
1. [Mdadm](#mdadm) - SNMP extend
|
||||
1. [MegaRAID](#megaraid) - SNMP extend
|
||||
1. [Memcached](#memcached) - SNMP extend
|
||||
1. [Munin](#munin) - Agent
|
||||
1. [MySQL](#mysql) - SNMP extend, Agent
|
||||
@ -924,6 +925,21 @@ The application should be auto-discovered as described at the
|
||||
top of the page. If it is not, please follow the steps set out
|
||||
under `SNMP Extend` heading top of page.
|
||||
|
||||
|
||||
## MegaRAID
|
||||
|
||||
This software from Broadcom/LSI let you monitor MegaRAID controller.
|
||||
|
||||
1. Download the [external software](https://docs.broadcom.com/docs/1211132411799) and follow the included install instructions.
|
||||
|
||||
2. Add the following line to your snmpd.conf file (usually /etc/snmp/snmpd.conf)
|
||||
```
|
||||
pass .1.3.6.1.4.1.3582 /usr/sbin/lsi_mrdsnmpmain
|
||||
```
|
||||
|
||||
3. Restart snmpd on your host
|
||||
|
||||
|
||||
## Memcached
|
||||
|
||||
### SNMP Extend
|
||||
|
142
includes/definitions/discovery/linux.yaml
Normal file
142
includes/definitions/discovery/linux.yaml
Normal file
@ -0,0 +1,142 @@
|
||||
mib: LSI-MegaRAID-SAS-MIB
|
||||
modules:
|
||||
sensors:
|
||||
temperature:
|
||||
data:
|
||||
-
|
||||
oid: adapterPropertiesTable
|
||||
value: temperatureROC
|
||||
num_oid: '.1.3.6.1.4.1.3582.4.1.4.1.2.1.42.{{ $index }}'
|
||||
index: 'controllertemp.{{ $index }}'
|
||||
group: 'RAID Controller {{ $adapterID-APT }}'
|
||||
descr: 'Controller'
|
||||
-
|
||||
oid: bbuTable
|
||||
value: temperature
|
||||
num_oid: '.1.3.6.1.4.1.3582.4.1.4.1.6.2.1.16.{{ $index }}'
|
||||
index: 'bbutemp.{{ $index }}'
|
||||
group: 'RAID Controller {{ $adpID }}'
|
||||
descr: 'BBU'
|
||||
-
|
||||
oid: physicalDriveTable
|
||||
value: pdTemperature
|
||||
num_oid: '.1.3.6.1.4.1.3582.4.1.4.2.1.2.1.36.{{ $index }}'
|
||||
index: 'slot.{{ $index }}'
|
||||
group: 'RAID Controller {{ $adpID-PDT }} Enclosure {{ enclDeviceId }}'
|
||||
descr: '/c{{ $adpID-PDT }}/e{{ $enclDeviceId }}/s{{ $slotNumber }}'
|
||||
count:
|
||||
data:
|
||||
-
|
||||
oid: adapterPropertiesTable
|
||||
value: vdPresentCount
|
||||
num_oid: '.1.3.6.1.4.1.3582.4.1.4.1.2.1.18.{{ $index }}'
|
||||
index: 'vdsum.{{ $index }}'
|
||||
group: 'RAID Controller {{ $adapterID-APT }}'
|
||||
descr: 'Virtual disks'
|
||||
-
|
||||
oid: adapterPropertiesTable
|
||||
value: pdDiskPredFailureCount
|
||||
num_oid: '.1.3.6.1.4.1.3582.4.1.4.1.2.1.19.{{ $index }}'
|
||||
index: 'vdfail.{{ $index }}'
|
||||
group: 'RAID Controller {{ $adapterID-APT }}'
|
||||
warn_limit: 1
|
||||
descr: 'Virtual disk failure'
|
||||
-
|
||||
oid: adapterPropertiesTable
|
||||
value: pdDiskPredFailureCount
|
||||
num_oid: '.1.3.6.1.4.1.3582.4.1.4.1.2.1.23.{{ $index }}'
|
||||
index: 'criticaldisks.{{ $index }}'
|
||||
group: 'RAID Controller {{ $adapterID-APT }}'
|
||||
warn_limit: 1
|
||||
descr: 'Critical disks'
|
||||
-
|
||||
oid: adapterPropertiesTable
|
||||
value: pdDiskFailedCount
|
||||
num_oid: '.1.3.6.1.4.1.3582.4.1.4.1.2.1.24.{{ $index }}'
|
||||
index: 'faileddisks.{{ $index }}'
|
||||
group: 'RAID Controller {{ $adapterID-APT }}'
|
||||
warn_limit: 1
|
||||
descr: 'Failed disks'
|
||||
state:
|
||||
data:
|
||||
-
|
||||
oid: adapterPropertiesTable
|
||||
value: alarmState
|
||||
num_oid: '.1.3.6.1.4.1.3582.4.1.4.1.2.1.4.{{ $index }}'
|
||||
group: 'RAID Controller {{ $adapterID-APT }}'
|
||||
descr: 'Alarm'
|
||||
state_name: alarmState
|
||||
states:
|
||||
- { descr: disabled , graph: 0, value: 0, generic: 1 }
|
||||
- { descr: enabled , graph: 0, value: 1, generic: 0 }
|
||||
-
|
||||
oid: enclosurePowerSupplyTable
|
||||
value: powerSupplyStatus
|
||||
num_oid: '.1.3.6.1.4.1.3582.4.1.5.5.1.3.{{ $index }}'
|
||||
group: 'Enclosure {{ $enclosureId-EPST }}'
|
||||
descr: 'Powersupply {{ $powerSupplyID }}'
|
||||
state_name: powerSupplyStatus
|
||||
states:
|
||||
- { descr: invalid , graph: 0, value: 1, generic: 2 }
|
||||
- { descr: ok , graph: 0, value: 2, generic: 0 }
|
||||
- { descr: critical , graph: 0, value: 3, generic: 2 }
|
||||
- { descr: nonCritical , graph: 0, value: 4, generic: 1 }
|
||||
- { descr: unrecoverable , graph: 0, value: 5, generic: 2 }
|
||||
- { descr: notInstalled , graph: 0, value: 6, generic: 3 }
|
||||
- { descr: unknown , graph: 0, value: 7, generic: 1 }
|
||||
- { descr: notAvailible , graph: 0, value: 8, generic: 3 }
|
||||
-
|
||||
oid: enclosureFanTable
|
||||
value: fanStatus
|
||||
num_oid: '.1.3.6.1.4.1.3582.4.1.5.3.1.3.{{ $index }}'
|
||||
group: 'Enclosure {{ $enclosureId }}'
|
||||
descr: 'FAN {{ $fanID }}'
|
||||
state_name: fanStatus
|
||||
states:
|
||||
- { descr: invalid , graph: 0, value: 1, generic: 2 }
|
||||
- { descr: ok , graph: 0, value: 2, generic: 0 }
|
||||
- { descr: critical , graph: 0, value: 3, generic: 2 }
|
||||
- { descr: nonCritical , graph: 0, value: 4, generic: 1 }
|
||||
- { descr: unrecoverable , graph: 0, value: 5, generic: 2 }
|
||||
- { descr: notInstalled , graph: 0, value: 6, generic: 3 }
|
||||
- { descr: unknown , graph: 0, value: 7, generic: 1 }
|
||||
- { descr: notAvailible , graph: 0, value: 8, generic: 3 }
|
||||
-
|
||||
oid: enclosureAlarmTable
|
||||
value: alarmStatus
|
||||
num_oid: '.1.3.6.1.4.1.3582.4.1.5.7.{{ $index }}'
|
||||
group: 'Enclosure {{ $enclosureId-EAT }}'
|
||||
descr: 'Alarm'
|
||||
state_name: alarmStatus
|
||||
states:
|
||||
- { descr: invalid , graph: 0, value: 1, generic: 2 }
|
||||
- { descr: ok , graph: 0, value: 2, generic: 0 }
|
||||
- { descr: critical , graph: 0, value: 3, generic: 2 }
|
||||
- { descr: nonCritical , graph: 0, value: 4, generic: 1 }
|
||||
- { descr: unrecoverable , graph: 0, value: 5, generic: 2 }
|
||||
- { descr: notInstalled , graph: 0, value: 6, generic: 3 }
|
||||
- { descr: unknown , graph: 0, value: 7, generic: 1 }
|
||||
- { descr: notAvailible , graph: 0, value: 8, generic: 3 }
|
||||
-
|
||||
oid: bbuTable
|
||||
value: chargerStatus
|
||||
num_oid: '.1.3.6.1.4.1.3582.4.1.4.1.6.2.1.20.{{ $index }}'
|
||||
group: 'RAID Controller {{ $adpID }}'
|
||||
descr: 'BBU charger'
|
||||
state_name: chargerStatus
|
||||
states:
|
||||
- { descr: notAvailible, graph: 0, value: -1, generic: 3 }
|
||||
- { descr: off , graph: 0, value: 0, generic: 2 }
|
||||
- { descr: complete , graph: 0, value: 1, generic: 0 }
|
||||
- { descr: progress , graph: 0, value: 2, generic: 1 }
|
||||
-
|
||||
oid: bbuTable
|
||||
value: batteryReplacement
|
||||
num_oid: '.1.3.6.1.4.1.3582.4.1.4.1.6.2.1.27.{{ $index }}'
|
||||
group: 'RAID Controller {{ $adpID }}'
|
||||
descr: 'BBU replacement'
|
||||
state_name: batteryReplacement
|
||||
states:
|
||||
- { descr: not availible , graph: 0, value: -1, generic: 3 }
|
||||
- { descr: needsReplacement , graph: 0, value: 1, generic: 2 }
|
||||
- { descr: ok , graph: 0, value: 0, generic: 0 }
|
113
includes/discovery/entity-physical/linux.inc.php
Normal file
113
includes/discovery/entity-physical/linux.inc.php
Normal file
@ -0,0 +1,113 @@
|
||||
<?php
|
||||
|
||||
$controller_array = snmpwalk_cache_multi_oid($device, 'adapterInfoTable', $controller_array, 'LSI-MegaRAID-SAS-MIB');
|
||||
$enclosures = snmpwalk_cache_multi_oid($device, 'enclosureTable', $enclosures, 'LSI-MegaRAID-SAS-MIB');
|
||||
$drives = snmpwalk_cache_multi_oid($device, 'physicalDriveTable', $drives, 'LSI-MegaRAID-SAS-MIB');
|
||||
$bbus = snmpwalk_cache_multi_oid($device, 'bbuTable', $bbus, 'LSI-MegaRAID-SAS-MIB');
|
||||
|
||||
foreach ($controller_array as $controller) {
|
||||
// Discover the chassis
|
||||
$entity_array[] = [
|
||||
'entPhysicalIndex' => 200 + $controller['adapterID-AIT'],
|
||||
'entPhysicalParentRelPos' => $controller['adapterID-AIT'],
|
||||
'entPhysicalDescr' => '/C' . $controller['adapterID-AIT'],
|
||||
'entPhysicalClass' => 'port',
|
||||
'entPhysicalModelName' => $controller['productName'],
|
||||
'entPhysicalSerialNum' => $controller['serialNo'],
|
||||
'entPhysicalContainedIn' => '0',
|
||||
'entPhysicalVendorType' => $controller['adapterVendorID'],
|
||||
'entPhysicalFirmwareRev' => $controller['firmwareVersion'],
|
||||
];
|
||||
}
|
||||
|
||||
foreach ($bbus as $bbu) {
|
||||
// Discover the chassis
|
||||
$entity_array[] = [
|
||||
'entPhysicalIndex' => 1000 + $bbu['pdIndex'],
|
||||
'entPhysicalClass' => 'charge',
|
||||
'entPhysicalModelName' => $bbu['deviceName'],
|
||||
'entPhysicalSerialNum' => $bbu['serialNumber'],
|
||||
'entPhysicalContainedIn' => 200 + $bbu['adpID'],
|
||||
'entPhysicalIsFRU' => 'true',
|
||||
'entPhysicalFirmwareRev' => $bbu['firmwareStatus'],
|
||||
];
|
||||
}
|
||||
|
||||
foreach ($enclosures as $enclosure) {
|
||||
// Discover the chassis
|
||||
$entity_array[] = [
|
||||
'entPhysicalIndex' => 210 + $enclosure['deviceId'],
|
||||
'entPhysicalMfgName' => $enclosure['slotCount'],
|
||||
'entPhysicalParentRelPos' => $enclosure['deviceId'],
|
||||
'entPhysicalDescr' => '/C' . $enclosure['adapterID-CDIT'] . '/E' . $enclosure['deviceId'],
|
||||
'entPhysicalClass' => 'chassis',
|
||||
'entPhysicalModelName' => $enclosure['productID'],
|
||||
'entPhysicalSerialNum' => $enclosure['enclSerialNumber'],
|
||||
'entPhysicalContainedIn' => 200 + $enclosure['adapterID-CDIT'],
|
||||
'entPhysicalVendorType' => $enclosure['adapterVendorID'],
|
||||
'entPhysicalFirmwareRev' => $enclosure['firmwareVersion'],
|
||||
];
|
||||
}
|
||||
|
||||
foreach ($drives as $drive) {
|
||||
// Discover the chassis
|
||||
$entity_array[] = [
|
||||
'entPhysicalIndex' => 500 + $drive['enclDeviceId'] * 100 + $drive['physDevID'],
|
||||
'entPhysicalParentRelPos' => $drive['slotNumber'],
|
||||
'entPhysicalDescr' => '/C' . $drive['adpID-PDT'] . '/E' . $drive['enclDeviceId'] . '/S' . $drive['slotNumber'],
|
||||
'entPhysicalClass' => 'drive',
|
||||
'entPhysicalModelName' => $drive['pdProductID'],
|
||||
'entPhysicalSerialNum' => $drive['pdSerialNumber'],
|
||||
'entPhysicalContainedIn' => 210 + $drive['enclDeviceId'],
|
||||
'entPhysicalIsFRU' => 'true',
|
||||
'entPhysicalFirmwareRev' => $drive['pdFwversion'],
|
||||
];
|
||||
}
|
||||
|
||||
foreach ($entity_array as $entPhysicalIndex => $entry) {
|
||||
$entPhysicalIndex = array_key_exists('entPhysicalIndex', $entry) ? $entry['entPhysicalIndex'] : '';
|
||||
$entPhysicalDescr = array_key_exists('entPhysicalDescr', $entry) ? $entry['entPhysicalDescr'] : '';
|
||||
$entPhysicalClass = array_key_exists('entPhysicalClass', $entry) ? $entry['entPhysicalClass'] : '';
|
||||
$entPhysicalName = array_key_exists('entPhysicalName', $entry) ? $entry['entPhysicalName'] : '';
|
||||
$entPhysicalModelName = array_key_exists('entPhysicalModelName', $entry) ? $entry['entPhysicalModelName'] : '';
|
||||
$entPhysicalSerialNum = array_key_exists('entPhysicalSerialNum', $entry) ? $entry['entPhysicalSerialNum'] : '';
|
||||
$entPhysicalContainedIn = array_key_exists('entPhysicalContainedIn', $entry) ? $entry['entPhysicalContainedIn'] : '';
|
||||
$entPhysicalMfgName = array_key_exists('entPhysicalMfgName', $entry) ? $entry['entPhysicalMfgName'] : '';
|
||||
$entPhysicalParentRelPos = array_key_exists('entPhysicalParentRelPos', $entry) ? $entry['entPhysicalParentRelPos'] : '';
|
||||
$entPhysicalVendorType = array_key_exists('entPhysicalVendorType', $entry) ? $entry['entPhysicalVendorType'] : '';
|
||||
$entPhysicalHardwareRev = array_key_exists('entPhysicalHardwareRev', $entry) ? $entry['entPhysicalHardwareRev'] : '';
|
||||
$entPhysicalFirmwareRev = array_key_exists('entPhysicalFirmwareRev', $entry) ? $entry['entPhysicalFirmwareRev'] : '';
|
||||
$entPhysicalSoftwareRev = array_key_exists('entPhysicalSoftwareRev', $entry) ? $entry['entPhysicalSoftwareRev'] : '';
|
||||
$entPhysicalIsFRU = array_key_exists('entPhysicalIsFRU', $entry) ? $entry['entPhysicalIsFRU'] : '';
|
||||
$entPhysicalAlias = array_key_exists('entPhysicalAlias', $entry) ? $entry['entPhysicalAlias'] : '';
|
||||
$entPhysicalAssetID = array_key_exists('entPhysicalAssetID', $entry) ? $entry['entPhysicalAssetID'] : '';
|
||||
$ifIndex = array_key_exists('ifIndex', $entry) ? $entry['ifIndex'] : '';
|
||||
|
||||
discover_entity_physical($valid,
|
||||
$device,
|
||||
$entPhysicalIndex,
|
||||
$entPhysicalDescr,
|
||||
$entPhysicalClass,
|
||||
$entPhysicalName,
|
||||
$entPhysicalModelName,
|
||||
$entPhysicalSerialNum,
|
||||
$entPhysicalContainedIn,
|
||||
$entPhysicalMfgName,
|
||||
$entPhysicalParentRelPos,
|
||||
$entPhysicalVendorType,
|
||||
$entPhysicalHardwareRev,
|
||||
$entPhysicalFirmwareRev,
|
||||
$entPhysicalSoftwareRev,
|
||||
$entPhysicalIsFRU,
|
||||
$entPhysicalAlias,
|
||||
$entPhysicalAssetID,
|
||||
$ifIndex);
|
||||
}//end foreach
|
||||
|
||||
echo "\n";
|
||||
unset(
|
||||
$update_data,
|
||||
$insert_data,
|
||||
$entry,
|
||||
$entity_array
|
||||
);
|
5898
mibs/LSI-MegaRAID-SAS-MIB
Normal file
5898
mibs/LSI-MegaRAID-SAS-MIB
Normal file
File diff suppressed because it is too large
Load Diff
4143
tests/data/linux_lsi.json
Normal file
4143
tests/data/linux_lsi.json
Normal file
File diff suppressed because it is too large
Load Diff
2673
tests/snmpsim/linux_lsi.snmprec
Normal file
2673
tests/snmpsim/linux_lsi.snmprec
Normal file
File diff suppressed because it is too large
Load Diff
Loading…
Reference in New Issue