diff --git a/includes/definitions/discovery/logmaster.yaml b/includes/definitions/discovery/logmaster.yaml
new file mode 100644
index 0000000000..0aed883089
--- /dev/null
+++ b/includes/definitions/discovery/logmaster.yaml
@@ -0,0 +1,62 @@
+mib: UPS-MIB:XPPC-MIB
+modules:
+ sensors:
+ temperature:
+ data:
+ -
+ oid: upsEnvTemperature
+ num_oid: .1.3.6.1.4.1.935.1.1.1.9.1.1.
+ index: 'upsEnvTemperature.{{ $index }}'
+ descr: Environment
+ humidity:
+ data:
+ -
+ oid: upsEnvHumidity
+ num_oid: .1.3.6.1.4.1.935.1.1.1.9.1.2.
+ index: 'upsEnvHumidity.{{ $index }}'
+ descr: Environment
+ state:
+ data:
+ -
+ oid: upsSmartBatteryReplaceIndicator
+ num_oid: .1.3.6.1.4.1.935.1.1.1.2.2.5.
+ descr: Battery Replace Status
+ index: 'upsSmartBatteryReplaceIndicator.{{ $index }}'
+ state_name: upsSmartBatteryReplaceIndicator
+ states:
+ - { descr: noBatteryNeedsReplacing, graph: 0, value: 1, generic: 0 }
+ - { descr: batteryNeedsReplacing, graph: 0, value: 2, generic: 2 }
+ -
+ oid: upsBaseOutputStatus
+ num_oid: .1.3.6.1.4.1.935.1.1.1.4.1.1.
+ descr: Output Status
+ index: 'upsBaseOutputStatus.{{ $index }}'
+ state_name: upsBaseOutputStatus
+ states:
+ - { descr: unknown, graph: 0, value: 1, generic: 3 }
+ - { descr: onLine, graph: 0, value: 2, generic: 0 }
+ - { descr: onBattery, graph: 0, value: 3, generic: 1 }
+ - { descr: onBoost, graph: 0, value: 4, generic: 1 }
+ - { descr: sleeping, graph: 0, value: 5, generic: 1 }
+ - { descr: onBypass, graph: 0, value: 6, generic: 3 }
+ - { descr: rebooting, graph: 0, value: 7, generic: 3 }
+ - { descr: standBy, graph: 0, value: 8, generic: 1 }
+ - { descr: onBuck, graph: 0, value: 9, generic: 1 }
+ -
+ oid: upsEnvWater
+ num_oid: .1.3.6.1.4.1.935.1.1.1.9.1.3.
+ descr: Water Status
+ index: 'upsEnvWater.{{ $index }}'
+ state_name: upsEnvWater
+ states:
+ - { descr: normal, graph: 0, value: 1, generic: 0 }
+ - { descr: abnormal, graph: 0, value: 2, generic: 1 }
+ -
+ oid: upsEnvSmoke
+ num_oid: .1.3.6.1.4.1.935.1.1.1.9.1.4.
+ descr: Smoke Status
+ index: 'upsEnvSmoke.{{ $index }}'
+ state_name: upsEnvSmoke
+ states:
+ - { descr: normal, graph: 0, value: 1, generic: 0 }
+ - { descr: abnormal, graph: 0, value: 2, generic: 1 }
\ No newline at end of file
diff --git a/includes/definitions/logmaster.yaml b/includes/definitions/logmaster.yaml
new file mode 100644
index 0000000000..300e5413fa
--- /dev/null
+++ b/includes/definitions/logmaster.yaml
@@ -0,0 +1,40 @@
+os: logmaster
+text: 'LogMaster'
+type: power
+rfc1628_compat: 1
+icon: logmaster
+mib_dir:
+ - logmaster
+discovery:
+ -
+ sysObjectId: .1.3.6.1.4.1.935
+ sysDescr: 'LogWeb'
+discovery_modules:
+ arp-table: 0
+ bgp-peers: 0
+ cisco-vrf-lite: 0
+ entity-physical: 0
+ ports: 0
+ ports-stack: 0
+ mempools: 0
+ discovery-protocols: 0
+ storage: 0
+ ucd-diskio: 0
+poller_modules:
+ bgp-peers: 0
+ entity-physical: 0
+ hr-mib: 0
+ ipSystemStats: 0
+ ipmi: 0
+ ntp: 0
+ ospf: 0
+ processors: 0
+ services: 0
+ netstats: 0
+ ports: 0
+ stp: 0
+ mempools: 0
+ storage: 0
+ ucd-diskio: 0
+ ucd-mib: 0
+ wireless: 0
diff --git a/mibs/XPPC-MIB b/mibs/XPPC-MIB
new file mode 100644
index 0000000000..526a308559
--- /dev/null
+++ b/mibs/XPPC-MIB
@@ -0,0 +1,2349 @@
+--PPC-MIB { iso(1) org(3) dod(6) internet(1) private(4)
+-- enterprises(1) ppc(935) }
+-- Title: PPC TOP LEVEL MIB
+-- Date: January 07, 1994 Version 1.00
+--
+-- Date: January 17, 1994 Version 1.01
+--
+-- Date: July 14, 1994 Version 1.02
+--
+-- Date: May 16, 2003 Version 2.00
+
+XPPC-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ TRAP-TYPE
+ FROM RFC-1215
+ DisplayString
+ FROM RFC1213-MIB
+ OBJECT-TYPE
+ FROM RFC-1212
+ enterprises,
+ IpAddress
+ FROM RFC1155-SMI;
+
+
+ppc OBJECT IDENTIFIER
+ ::= { enterprises 935 }
+
+products OBJECT IDENTIFIER
+ ::= { ppc 1 }
+
+ppcmgmt OBJECT IDENTIFIER
+ ::= { ppc 2 }
+
+hardware OBJECT IDENTIFIER
+ ::= { products 1 }
+
+mconfig OBJECT IDENTIFIER
+ ::= { ppcmgmt 1 }
+
+ups OBJECT IDENTIFIER
+ ::= { hardware 1 }
+
+upsIdentp OBJECT IDENTIFIER
+ ::= { ups 1 }
+
+upsBatteryp OBJECT IDENTIFIER
+ ::= { ups 2 }
+
+upsInputp OBJECT IDENTIFIER
+ ::= { ups 3 }
+
+upsOutputp OBJECT IDENTIFIER
+ ::= { ups 4 }
+
+upsConfigp OBJECT IDENTIFIER
+ ::= { ups 5 }
+
+upsControlp OBJECT IDENTIFIER
+ ::= { ups 6 }
+
+upsTestp OBJECT IDENTIFIER
+ ::= { ups 7 }
+
+upsThreePhase OBJECT IDENTIFIER
+ ::= { ups 8 }
+
+upsEnvironment OBJECT IDENTIFIER
+ ::= { ups 9 }
+
+upsBaseIdent OBJECT IDENTIFIER
+ ::= { upsIdentp 1 }
+
+upsSmartIdent OBJECT IDENTIFIER
+ ::= { upsIdentp 2 }
+
+upsBaseBattery OBJECT IDENTIFIER
+ ::= { upsBatteryp 1 }
+
+upsSmartBattery OBJECT IDENTIFIER
+ ::= { upsBatteryp 2 }
+
+upsBaseInput OBJECT IDENTIFIER
+ ::= { upsInputp 1 }
+
+upsSmartInput OBJECT IDENTIFIER
+ ::= { upsInputp 2 }
+
+upsBaseOutput OBJECT IDENTIFIER
+ ::= { upsOutputp 1 }
+
+upsSmartOutput OBJECT IDENTIFIER
+ ::= { upsOutputp 2 }
+
+upsBaseConfig OBJECT IDENTIFIER
+ ::= { upsConfigp 1 }
+
+upsSmartConfig OBJECT IDENTIFIER
+ ::= { upsConfigp 2 }
+
+upsBaseControl OBJECT IDENTIFIER
+ ::= { upsControlp 1 }
+
+upsSmartControl OBJECT IDENTIFIER
+ ::= { upsControlp 2 }
+
+upsBaseTest OBJECT IDENTIFIER
+ ::= { upsTestp 1 }
+
+upsSmartTest OBJECT IDENTIFIER
+ ::= { upsTestp 2 }
+
+upsThreePhaseBatteryGrp OBJECT IDENTIFIER
+ ::= { upsThreePhase 1 }
+
+upsThreePhaseInputGrp OBJECT IDENTIFIER
+ ::= { upsThreePhase 2 }
+
+upsThreePhaseOutputGrp OBJECT IDENTIFIER
+ ::= { upsThreePhase 3 }
+
+upsThreePhaseBypassGrp OBJECT IDENTIFIER
+ ::= { upsThreePhase 4 }
+
+upsThreePhaseDCandRectifierStatusGrp OBJECT IDENTIFIER
+ ::= { upsThreePhase 5 }
+
+upsThreePhaseUPSStatusGrp OBJECT IDENTIFIER
+ ::= { upsThreePhase 6 }
+
+upsThreePhaseFaultStatusGrp OBJECT IDENTIFIER
+ ::= { upsThreePhase 7 }
+
+upsThreePhaseRatingGrp OBJECT IDENTIFIER
+ ::= { upsThreePhase 8 }
+
+-- object types
+-- the ppcmgmt group
+-- the mconfig group
+
+mconfigTrapsReceiversNum OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of managers to send traps to."
+ ::= { mconfig 1 }
+
+
+mconfigTrapsReceiversTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF MconfigTrapsReceiversEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of managers to send traps to. The number of
+ entries is given by the value of mconfigNumTrapReceivers"
+ ::= { mconfig 2 }
+
+
+mconfigTrapsReceiversEntry OBJECT-TYPE
+ SYNTAX MconfigTrapsReceiversEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The managers to send traps to."
+ INDEX {
+ trapsIndex }
+ ::= { mconfigTrapsReceiversTable 1 }
+
+
+MconfigTrapsReceiversEntry ::= SEQUENCE {
+ trapsIndex INTEGER,
+ trapsReceiverAddr IpAddress,
+ receiverCommunityString DisplayString,
+ severityLevel INTEGER,
+ receiverAccept INTEGER }
+
+
+trapsIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to a trap receiver entry."
+ ::= { mconfigTrapsReceiversEntry 1 }
+
+
+trapsReceiverAddr OBJECT-TYPE
+ SYNTAX IpAddress
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The IP address of the manager to send a trap to."
+ ::= { mconfigTrapsReceiversEntry 2 }
+
+
+receiverCommunityString OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The community name to use in the trap when
+ sent to the manager."
+ ::= { mconfigTrapsReceiversEntry 3 }
+
+
+severityLevel OBJECT-TYPE
+ SYNTAX INTEGER {
+ information(1),
+ warning(2),
+ severe(3) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The severity threshold of traps to send to the manager.
+ traps are labeled in severity as informational(1), warning(2),
+ severe(3). Only traps of equal or greater severity than
+ this value are sent to the manager."
+ ::= { mconfigTrapsReceiversEntry 4 }
+
+
+receiverAccept OBJECT-TYPE
+ SYNTAX INTEGER {
+ yes(1),
+ no(2) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "An entry will become active if yes, and will
+ be deleted if no."
+ ::= { mconfigTrapsReceiversEntry 5 }
+
+
+-- the ups group
+-- the upsBaseIdent group
+
+upsBaseIdentModel OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The UPS model name (e.g. 'Intelligent 8000E 900VA')."
+ ::= { upsBaseIdent 1 }
+
+
+upsBaseIdentUpsName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "An 8 byte ID string identifying the UPS. This object
+ can be set by the administrator."
+ ::= { upsBaseIdent 2 }
+
+
+-- the upsSmartIdent group
+
+upsSmartIdentFirmwareRevision OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The firmware revision of the UPS system."
+ ::= { upsSmartIdent 1 }
+
+
+upsSmartIdentDateOfManufacture OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The date when the UPS was manufactured in mm/dd/yy format."
+ ::= { upsSmartIdent 2 }
+
+
+upsSmartIdentUpsSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "An 8-character string identifying the serial number of
+ the UPS internal microprocessor. This number is set at
+ the factory. NOTE: This number does NOT correspond to
+ the serial number on the rear of the UPS."
+ ::= { upsSmartIdent 3 }
+
+
+upsSmartIdentAgentFirmwareRevision OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The firmware revision of the UPS SNMP Proxy agent."
+ ::= { upsSmartIdent 4 }
+
+
+-- the upsBaseBattery group
+
+upsBaseBatteryStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(1),
+ batteryNormal(2),
+ batteryLow(3) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The status of the UPS batteries. A batteryLow(3)
+ value indicates the UPS will be unable to sustain the
+ current load, and its services will be lost if power is
+ not restored. The amount of run time in reserve at the
+ time of low battery can be configured by the
+ upsSmartConfigLowBatteryRunTime."
+ ::= { upsBaseBattery 1 }
+
+
+upsBaseBatteryTimeOnBattery OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The elapsed time in seconds since the UPS has switched
+ to battery power."
+ ::= { upsBaseBattery 2 }
+
+
+upsBaseBatteryLastReplaceDate OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The date when the UPS system's batteries were last replaced
+ in mm/dd/yy format. For UPS models, this value is originally
+ set in the factory. When the UPS batteries are replaced,
+ this value should be reset by the administrator."
+ ::= { upsBaseBattery 3 }
+
+
+-- the upsSmartBattery group
+
+upsSmartBatteryCapacity OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The remaining battery capacity expressed in
+ percent of full capacity."
+ ::= { upsSmartBattery 1 }
+
+
+upsSmartBatteryVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current battery voltage expressed in 1/10 VDC."
+ ::= { upsSmartBattery 2 }
+
+
+upsSmartBatteryTemperature OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current internal UPS temperature expressed in tenths of
+ a Celsius degree."
+ ::= { upsSmartBattery 3 }
+
+
+upsSmartBatteryRunTimeRemaining OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The UPS battery run time remaining before battery
+ exhaustion, in seconds."
+ ::= { upsSmartBattery 4 }
+
+
+upsSmartBatteryReplaceIndicator OBJECT-TYPE
+ SYNTAX INTEGER {
+ noBatteryNeedsReplacing(1),
+ batteryNeedsReplacing(2) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates whether the UPS batteries need replacing."
+ ::= { upsSmartBattery 5 }
+
+
+upsSmartBatteryFullChargeVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The fully charged battery voltage of the battery system
+ used in the UPS, expressed in tenths of a volt."
+ ::= { upsSmartBattery 6 }
+
+
+upsSmartBatteryCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current battery current expressed in percent of
+ maximum current."
+ ::= { upsSmartBattery 7 }
+
+
+-- the upsBaseInput group
+
+upsBaseInputPhase OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current AC input phase."
+ ::= { upsBaseInput 1 }
+
+
+-- the upsSmartInput group
+
+upsSmartInputLineVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current utility line voltage in 1/10 VAC."
+ ::= { upsSmartInput 1 }
+
+
+upsSmartInputMaxLineVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum utility line voltage in 1/10 VAC over the
+ previous 1 minute period."
+ ::= { upsSmartInput 2 }
+
+
+upsSmartInputMinLineVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The minimum utility line voltage in 1/10 VAC over the
+ previous 1 minute period."
+ ::= { upsSmartInput 3 }
+
+
+upsSmartInputFrequency OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current input frequency to the UPS system in 1/10 Hz."
+ ::= { upsSmartInput 4 }
+
+
+upsSmartInputLineFailCause OBJECT-TYPE
+ SYNTAX INTEGER {
+ noTransfer(1),
+ highLineVoltage(2),
+ brownout(3),
+ blackout(4),
+ smallMomentarySag(5),
+ deepMomentarySag(6),
+ smallMomentarySpike(7),
+ largeMomentarySpike(8) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The reason for the occurrence of the last transfer
+ to UPS battery power. The variable is set to
+ noTransfer(1) if there is no transfer yet. The variable
+ is set to highLineVoltage(2) if the transfer to battery is
+ caused by an over voltage greater than the high transfer
+ voltage. The variable is set to brownout(3) if the duration
+ of the outage is greater than five seconds and the line
+ voltage is between 40 percent of the rated output voltage and
+ the low transfer voltage. The variable is set to blackout(4)
+ if the duration of the outage is greater than five seconds and
+ the line voltage is between 40 percent of the rated output voltage
+ and ground. The variable is set to smallMomentarySag(5)
+ if the duration of the outage is less than five seconds and
+ the line voltage is between 40 percent of the rated output voltage
+ and the low transfer voltage. The variable is set to
+ deepMomentarySag(6) if the duration of the outage is less
+ than five seconds and the line voltage is between 40 percent of the
+ rated output voltage and ground."
+ ::= { upsSmartInput 5 }
+
+
+-- the upsBaseOutput group
+
+upsBaseOutputStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(1),
+ onLine(2),
+ onBattery(3),
+ onBoost(4),
+ sleeping(5),
+ onBypass(6),
+ rebooting(7),
+ standBy(8),
+ onBuck(9) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current state of the UPS. If the UPS is unable
+ to determine the state of the UPS this variable is set
+ to unknown(1)."
+ ::= { upsBaseOutput 1 }
+
+
+upsBaseOutputPhase OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current output phase."
+ ::= { upsBaseOutput 2 }
+
+
+-- the upsSmartOutput group
+
+upsSmartOutputVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The output voltage of the UPS system in 1/10 VAC."
+ ::= { upsSmartOutput 1 }
+
+
+upsSmartOutputFrequency OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current output frequency of the UPS system in 1/10 Hz."
+ ::= { upsSmartOutput 2 }
+
+
+upsSmartOutputLoad OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current UPS load expressed in percent
+ of rated capacity."
+ ::= { upsSmartOutput 3 }
+
+
+-- the upsBaseConfig group
+
+upsBaseConfigNumDevices OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of devices that are plugged into the UPS."
+ ::= { upsBaseConfig 1 }
+
+
+upsBaseConfigDeviceTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF UpsBaseConfigDeviceEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of devices that are plugged into the UPS. The
+ number of entries is given by the value of
+ upsBaseConfigNumDevices."
+ ::= { upsBaseConfig 2 }
+
+
+upsBaseConfigDeviceEntry OBJECT-TYPE
+ SYNTAX UpsBaseConfigDeviceEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The devices plugged in to the UPS."
+ INDEX {
+ indexOfDevice }
+ ::= { upsBaseConfigDeviceTable 1 }
+
+
+UpsBaseConfigDeviceEntry ::= SEQUENCE {
+ indexOfDevice INTEGER,
+ nameOfDevice DisplayString,
+ vaRatingOfDevice INTEGER,
+ deviceAccept INTEGER }
+
+
+indexOfDevice OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index of the device that is plugged into the UPS."
+ ::= { upsBaseConfigDeviceEntry 1 }
+
+
+nameOfDevice OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The name/description of the device plugged into the UPS."
+ ::= { upsBaseConfigDeviceEntry 2 }
+
+
+vaRatingOfDevice OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The volt-amp rating of the device plugged into the UPS."
+ ::= { upsBaseConfigDeviceEntry 3 }
+
+
+deviceAccept OBJECT-TYPE
+ SYNTAX INTEGER {
+ yes(1),
+ no(2) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "An entry is added if yes, the entry is deleted if no."
+ ::= { upsBaseConfigDeviceEntry 4 }
+
+
+-- the upsSmartConfig group
+
+upsSmartConfigRatedOutputVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The nominal output voltage from the UPS in 1/10 VAC.
+ Possible values are 1000, 1200, 2080, 2200, 2250, 2300
+ and 2400.
+
+ NOTE: Only units that are 2200, 2250, 2300 and 2400 can
+ be changed. Allowable values are 2200, 2250, 2300 and
+ 2400.
+
+ For these adjustable units, if a value other than
+ a supported value is provided in a set request, the
+ UPS interprets it as the next lower acceptable value.
+ If the provided value is lower than the lowest acceptable
+ value, the lowest acceptable value is used."
+ ::= { upsSmartConfig 1 }
+
+
+upsSmartConfigHighTransferVolt OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum line voltage in 1/10 VAC allowed before the
+ UPS system transfers to battery backup.
+
+ Allowed value depend on the UPS used:
+ 120 Volt units allow settings of 1290, 1320, 1350, 1380.
+ 100 Volt units allow settings of 1080, 1100, 1120, 1140.
+ 230 Volt units allow settings of 2530, 2640, 2710, 2800.
+ 208 Volt units allow settings of 2240, 2290, 2340, 2390.
+
+ If a value other than a supported value is provided in a
+ set request, the UPS interprets it as the next lower
+ acceptable value. If the provided value is lower than
+ the lowest acceptable value, the lowest acceptable
+ value is used."
+ ::= { upsSmartConfig 2 }
+
+
+upsSmartConfigLowTransferVolt OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The minimum line voltage in 1/10 VAC allowed before the
+ UPS system transfers to battery backup.
+
+ Allowable values depend on the UPS used:
+ 120 Volt units allow settings of 970, 1000, 1030, 1060.
+ 100 Volt units allow settings of 810, 830, 850, 870.
+ 230 Volt units allow settings of 1880, 1960, 2040, 2080.
+ 208 Volt units allow settings of 1680, 1720, 1770, 1820.
+
+ If a value other than a supported value is provided in a
+ set request, the UPS interprets it as a the next higher
+ acceptable value. If the provided value is higher than
+ the highest acceptable value, the highest acceptable
+ value is used."
+ ::= { upsSmartConfig 3 }
+
+
+upsSmartConfigAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ timed(1),
+ atLowBattery(2),
+ never(3) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A flag indicating how the UPS should handle audible line fail
+ alarms."
+ ::= { upsSmartConfig 4 }
+
+
+upsSmartConfigAlarmTimer OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The time in seconds after initial line failure at which the
+ UPS begins emitting audible alarms (beeping). This timer is
+ observerd only if the value of extControlAlarm is timed(2).
+ Allowed values are 0 or 30 seconds.
+
+ If a value other than a supported value is provided in a
+ set request, the UPS interprets it as a the next lower
+ acceptable value. If the provided value is lower than
+ the lowest acceptable value, the lowest acceptable
+ value is used."
+ ::= { upsSmartConfig 5 }
+
+
+upsSmartConfigMinReturnCapacity OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The minimum battery capacity as a percent of full capacity
+ required before the UPS will return from a low battery
+ shutdown condition. In other words, the UPS will not
+ re-energize the output until the battery capacity is equal
+ to this value. Allowed values are 0, 10, 25, or 90 percent.
+
+ If a value other than a supported value is provided in a
+ set request, the UPS interprets it as a the next higher
+ acceptable value. If the provided value is higher than
+ the highest acceptable value, the highest acceptable
+ value is used."
+ ::= { upsSmartConfig 6 }
+
+
+upsSmartConfigSensitivity OBJECT-TYPE
+ SYNTAX INTEGER {
+ auto(1),
+ low(2),
+ medium(3),
+ high(4) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The sensitivity of the UPS to utility line abnormalities
+ or noises."
+ ::= { upsSmartConfig 7 }
+
+
+upsSmartConfigLowBatteryRunTime OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The desired run time in seconds once the low battery
+ condition is reached. Allowed values are 120, 300, 420,
+ or 600 seconds. During this time the UPS will produce a
+ constant warning tone which can not be disabled.
+
+ If a value other than a supported value is provided in a
+ set request, the UPS interprets it as a the next higher
+ acceptable value. If the provided value is higher than
+ the highest acceptable value, the highest acceptable
+ value is used."
+ ::= { upsSmartConfig 8 }
+
+
+upsSmartConfigReturnDelay OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The delay in seconds after utility line power returns
+ before the UPS will turn on. This value is also used
+ when the UPS comes out of a reboot and before the UPS
+ wakes up from 'sleep' mode. Allowed values are 0, 60,
+ 180 and 300 seconds.
+
+ If a value other than a supported value is provided in a
+ set request, the UPS interprets it as a the next higher
+ acceptable value. If the provided value is higher than
+ the highest acceptable value, the highest acceptable
+ value is used."
+ ::= { upsSmartConfig 9 }
+
+
+upsSmartConfigShutoffDelay OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The delay in seconds the UPS remains on after being told
+ to turn off. Allowed values are 12, 18, 24, 30, 36, 42,
+ 48, 54, 60, 120, 180, 240, 300, 360, 420, 480, 540, and
+ 600 seconds.
+
+ If a value other than a supported value is provided in a
+ set request, the UPS interprets it as next higher acceptable
+ value. If the provided value is higher than the highest
+ acceptable value, the highest acceptable value is used."
+ ::= { upsSmartConfig 10 }
+
+
+upsSmartConfigUpsSleepTime OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The time in minutes for the UPS to go to 'sleep' when
+ instructed. When in sleep mode, the UPS will not provide
+ output power regardless of the input line state. Once the
+ specified time has elapsed, output power will be restored.
+
+ This is a configuration setting. The UPS will not go to
+ sleep until told to do so by the manager from a management
+ station.
+
+ Any input value is allowed, however the UPS only recognizes
+ 0 - 9999 minutes in one minute increments.
+
+ If the provided value is higher than the highest acceptable
+ value, the highest acceptable value is used."
+ ::= { upsSmartConfig 11 }
+
+
+upsSmartConfigSetEEPROMDefaults OBJECT-TYPE
+ SYNTAX INTEGER {
+ noSetEEPROMDefaults(1),
+ setEEPROMDefaults(2) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "WRITE: Resets the UPS EEPROM variables to default values.
+ READ: returns 0"
+ ::= { upsSmartConfig 12 }
+
+
+-- the upsBaseControl group
+
+upsBaseControlConserveBattery OBJECT-TYPE
+ SYNTAX INTEGER {
+ noTurnOffUps(1),
+ turnUpsOffToConserveBattery(2),
+ turnUpsOffToConserveBatteryDelay(3) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this variable to turnUpsOffToConserveBattery(2)
+ causes a UPS on battery to be put into 'sleep' mode immediately.
+ The (10) means suspending time(10 minutes) before turn off UPS.
+ UPS will turn back on when utility power is restored.
+ Attempting to turn off a UPS that is not on battery will
+ result in a badValue error.
+
+ Setting this value to noTurnOffUps(1) has no
+ effect.
+
+ The value noTurnOffUps(1) will always be returned
+ when the variable is read."
+ ::= { upsBaseControl 1 }
+
+
+-- the upsSmartControl group
+
+upsSmartControlUpsOff OBJECT-TYPE
+ SYNTAX INTEGER {
+ noTurnUpsOff(1),
+ turnUpsOff(2) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this variable to turnUpsOff(2) causes
+ the UPS to shut off. When in this state, the UPS
+ will not provide output power regardless of the input
+ line state. The on/off switch on the UPS
+ must be toggled for the UPS to return to operation.
+
+ Setting this value to noTurnUpsOff(1) has no
+ effect.
+
+ The value noTurnUpsOff(1) will always be returned
+ when the variable is read."
+ ::= { upsSmartControl 1 }
+
+
+upsSmartControlRebootUps OBJECT-TYPE
+ SYNTAX INTEGER {
+ noRebootUps(1),
+ rebootUps(2) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this variable to rebootUps(2) causes the
+ UPS to shut off and turn back on.
+
+ Setting this value to noRebootUps(1) has no effect.
+
+ The value noRebootUps(1) will always be returned
+ when the variable is read."
+ ::= { upsSmartControl 2 }
+
+
+upsSmartControlUpsSleep OBJECT-TYPE
+ SYNTAX INTEGER {
+ noPutUpsToSleep(1),
+ putUpsToSleep(2) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this variable to putUpsToSleep(2) causes
+ the UPS to go to sleep for the time specified by
+ upsSmartConfigUpsSleepTime.
+
+ When in sleep mode, the UPS will not provide output
+ power regardless of the input line state. Once the
+ specified time has elapsed, output power will be
+ restored.
+
+ Setting this value to noPutUpsToSleep(1) has no
+ effect.
+
+ The value noPutUpsToSleep(1) will always be returned
+ when the variable is read."
+ ::= { upsSmartControl 3 }
+
+
+upsSmartControlSimulatePowerFail OBJECT-TYPE
+ SYNTAX INTEGER {
+ noSimulatePowerFailure(1),
+ simulatePowerFailure(2) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this variable to simulatePowerFailure(2) causes
+ the UPS switch to battery power.
+
+ Setting this value to noSimulatePowerFailure(1) has no
+ effect.
+
+ The value noSimulatePowerFailure(1) will always be returned
+ when the variable is read."
+ ::= { upsSmartControl 4 }
+
+
+upsSmartControlFlashAndBeep OBJECT-TYPE
+ SYNTAX INTEGER {
+ noFlashAndBeep(1),
+ flashAndBeep(2) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "UPS to identify itself by lighting all indicators
+ and beeping.
+
+ Setting this variable to FlashAndBeep(2) causes
+ the UPS lights all panel indicators and beeps.
+
+ Setting this value to noFlashAndBeep(1) has no
+ effect.
+
+ The value noFlashAndBeep(1) will always be returned
+ when the variable is read."
+ ::= { upsSmartControl 5 }
+
+
+upsSmartControlTurnOnUpsLoad OBJECT-TYPE
+ SYNTAX INTEGER {
+ noUpsSmartControlTurnOnUpsLoad(1),
+ upsSmartControlTurnOnUpsLoad(2) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this variable to upsSmartControlTurnOnUpsLoad(2)
+ causes the UPS switch back to utility power if utility
+ power is present.
+
+ Setting this value to noUpsSmartControlTurnOnUpsLoad(1)
+ has no effect.
+
+ The value noUpsSmartControlTurnOnUpsLoad(1) will always
+ be returned when the variable is read."
+ ::= { upsSmartControl 6 }
+
+
+-- the upsBaseTest group
+-- the upsSmartTest group
+
+upsSmartTestDiagnosticSchedule OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(1),
+ biweekly(2),
+ weekly(3),
+ never(4) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The UPS system's automatic battery test schedule."
+ ::= { upsSmartTest 1 }
+
+
+upsSmartTestDiagnostics OBJECT-TYPE
+ SYNTAX INTEGER {
+ noTestDiagnostics(1),
+ testDiagnostics(2) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this variable to testDiagnostics(2) causes
+ the UPS to perform a diagnostic self test.
+
+ Setting this value to noTestDiagnostics(1) has no
+ effect.
+
+ The value noTestDiagnostics(1) will always be returned
+ when the variable is read."
+ ::= { upsSmartTest 2 }
+
+
+upsSmartTestDiagnosticsResults OBJECT-TYPE
+ SYNTAX INTEGER {
+ ok(1),
+ failed(2),
+ invalidTest(3),
+ testInProgress(4) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The results of the last UPS diagnostics test performed."
+ ::= { upsSmartTest 3 }
+
+
+upsSmartTestLastDiagnosticsDate OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The date the last UPS diagnostics test was performed in
+ mm/dd/yy format."
+ ::= { upsSmartTest 4 }
+
+
+upsSmartTestIndicators OBJECT-TYPE
+ SYNTAX INTEGER {
+ noTestIndicators(1),
+ testIndicators(2) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this variable to testIndicators(2) causes
+ the UPS to perform a front panel indicator (lights) test.
+
+ Setting this value to noTestIndicators(1) has no effect.
+
+ The value noTestIndicators(1) will always be returned
+ when the variable is read."
+ ::= { upsSmartTest 5 }
+
+
+upsSmartTestRuntimeCalibration OBJECT-TYPE
+ SYNTAX INTEGER {
+ noPerformCalibration(1),
+ performCalibration(2),
+ cancelCurrentCalibration(3) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this variable to performCalibration(2) causes
+ the UPS to discharge to calibrate the UPS.
+ The test will only start if the battery capacity is 100 percent.
+ The test runs until capacity is less than 25 percent.
+
+ Setting this variable to cancelCurrentCalibration(3)
+ after setting performCalibration(2) will cancel the
+ current discharge.
+
+ Setting this variable to noPerformCalibration(1)
+ will have no effect.
+
+ The value noPerformCalibration(1) will always be returned
+ when the variable is read.
+
+ The result of the calibration will be saved in
+ upsSmartTestCalibrationResult."
+ ::= { upsSmartTest 6 }
+
+
+upsSmartTestCalibrationResults OBJECT-TYPE
+ SYNTAX INTEGER {
+ ok(1),
+ invalidTest(2),
+ calibrationInProgress(3) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The results of the last runtime calibration.
+
+ Value ok(1) means a successful runtime calibration.
+
+ Value invalidTest(2) indicates last calibration did
+ not take place since the battery capacity was below
+ 100 percent.
+
+ Value calibrationInProgress(3) means a calibration
+ is occurring now."
+ ::= { upsSmartTest 7 }
+
+
+upsSmartTestCalibrationDate OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The date the last UPS runtime calibration was
+ performed in mm/dd/yy format."
+ ::= { upsSmartTest 8 }
+
+
+-----------------------
+--ups ThreePhase group-
+-----------------------
+upsThreePhaseBatteryVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Battery Voltage"
+ ::= { upsThreePhaseBatteryGrp 1 }
+
+
+upsThreePhaseBatteryCapacityPercentage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Battery Capacity Percentage"
+ ::= { upsThreePhaseBatteryGrp 2 }
+
+
+upsThreePhaseBatteryTimeRemain OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Battery Time Remain (unit is Minute)"
+ ::= { upsThreePhaseBatteryGrp 3 }
+
+
+upsThreePhaseBatteryCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Battery Electric Current"
+ ::= { upsThreePhaseBatteryGrp 4 }
+
+
+upsThreePhaseBatteryTemperature OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Battery Temperature"
+ ::= { upsThreePhaseBatteryGrp 5 }
+
+
+upsThreePhaseInputFrequency OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Input Frequency"
+ ::= { upsThreePhaseInputGrp 1 }
+
+
+upsThreePhaseInputVoltageR OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Input VoltageR"
+ ::= { upsThreePhaseInputGrp 2 }
+
+
+upsThreePhaseInputVoltageS OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Input VoltageS"
+ ::= { upsThreePhaseInputGrp 3 }
+
+
+upsThreePhaseInputVoltageT OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Input VoltageT"
+ ::= { upsThreePhaseInputGrp 4 }
+
+
+upsThreePhaseOutputFrequency OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Output Frequency"
+ ::= { upsThreePhaseOutputGrp 1 }
+
+
+upsThreePhaseOutputVoltageR OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Output VoltageR"
+ ::= { upsThreePhaseOutputGrp 2 }
+
+
+upsThreePhaseOutputVoltageS OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Output VoltageS"
+ ::= { upsThreePhaseOutputGrp 3 }
+
+
+upsThreePhaseOutputVoltageT OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Output VoltageT"
+ ::= { upsThreePhaseOutputGrp 4 }
+
+
+upsThreePhaseOutputLoadPercentageR OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Load PercentageR"
+ ::= { upsThreePhaseOutputGrp 5 }
+
+
+upsThreePhaseOutputLoadPercentageS OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Load PercentageS"
+ ::= { upsThreePhaseOutputGrp 6 }
+
+
+upsThreePhaseOutputLoadPercentageT OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Load PercentageT"
+ ::= { upsThreePhaseOutputGrp 7 }
+
+
+upsThreePhaseBypassSourceFrequency OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Bypass Frequency"
+ ::= { upsThreePhaseBypassGrp 1 }
+
+
+upsThreePhaseBypssSourceVoltageR OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Bypass VoltageR"
+ ::= { upsThreePhaseBypassGrp 2 }
+
+
+upsThreePhaseBypssSourceVoltageS OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Bypass VoltageS"
+ ::= { upsThreePhaseBypassGrp 3 }
+
+
+upsThreePhaseBypssSourceVoltageT OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Bypass VoltageT"
+ ::= { upsThreePhaseBypassGrp 4 }
+
+
+upsThreePhaseDCandRectifierStatusRecRotError OBJECT-TYPE
+ SYNTAX INTEGER {
+ yes(14),
+ no(16) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Rectifier Rotation Error"
+ ::= { upsThreePhaseDCandRectifierStatusGrp 1 }
+
+
+upsThreePhaseDCandRectifierStatusLowBatteryShutdown OBJECT-TYPE
+ SYNTAX INTEGER {
+ yes(14),
+ no(16) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Low Battery Shutdown"
+ ::= { upsThreePhaseDCandRectifierStatusGrp 2 }
+
+
+upsThreePhaseDCandRectifierStatusLowBattery OBJECT-TYPE
+ SYNTAX INTEGER {
+ yes(14),
+ no(16) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Low Battery"
+ ::= { upsThreePhaseDCandRectifierStatusGrp 3 }
+
+
+upsThreePhaseDCandRectifierStatusInAndOut OBJECT-TYPE
+ SYNTAX INTEGER {
+ threeInOneOut(2),
+ threeInThreeOut(3) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "In And Put"
+ ::= { upsThreePhaseDCandRectifierStatusGrp 4 }
+
+
+upsThreePhaseDCandRectifierStatusBatteryStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ backup(4),
+ acnormal(5) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Back Status"
+ ::= { upsThreePhaseDCandRectifierStatusGrp 5 }
+
+
+upsThreePhaseDCandRectifierStatusChargeStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ boost(6),
+ float(7),
+ no(16) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Charge Status"
+ ::= { upsThreePhaseDCandRectifierStatusGrp 6 }
+
+
+upsThreePhaseDCandRectifierStatusRecOperating OBJECT-TYPE
+ SYNTAX INTEGER {
+ yes(14),
+ no(16) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Rectifier Operating"
+ ::= { upsThreePhaseDCandRectifierStatusGrp 7 }
+
+
+upsThreePhaseUPSStatusBypassFreqFail OBJECT-TYPE
+ SYNTAX INTEGER {
+ yes(14),
+ no(16) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Bypass Status"
+ ::= { upsThreePhaseUPSStatusGrp 1 }
+
+
+upsThreePhaseUPSStatusManualBypassBreaker OBJECT-TYPE
+ SYNTAX INTEGER {
+ close(8),
+ open(9) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Breaker Status"
+ ::= { upsThreePhaseUPSStatusGrp 2 }
+
+
+upsThreePhaseUPSStatusACStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(10),
+ abnormal(11) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "AC Status"
+ ::= { upsThreePhaseUPSStatusGrp 3 }
+
+
+upsThreePhaseUPSStaticSwitchMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ invermode(12),
+ bypassmode(13) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Switch Mode"
+ ::= { upsThreePhaseUPSStatusGrp 4 }
+
+
+upsThreePhaseUPSStatusInverterOperating OBJECT-TYPE
+ SYNTAX INTEGER {
+ yes(14),
+ no(16) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Operating"
+ ::= { upsThreePhaseUPSStatusGrp 5 }
+
+
+upsThreePhaseFaultStatusEmergencyStop OBJECT-TYPE
+ SYNTAX INTEGER {
+ yes(14),
+ no(16) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Emergency Stop"
+ ::= { upsThreePhaseFaultStatusGrp 1 }
+
+
+upsThreePhaseFaultStatusHighDCShutdown OBJECT-TYPE
+ SYNTAX INTEGER {
+ yes(14),
+ no(16) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "High DC Shutdown"
+ ::= { upsThreePhaseFaultStatusGrp 2 }
+
+
+upsThreePhaseFaultStatusBypassBreaker OBJECT-TYPE
+ SYNTAX INTEGER {
+ yes(14),
+ no(16) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Bypass Breaker"
+ ::= { upsThreePhaseFaultStatusGrp 3 }
+
+
+upsThreePhaseFaultStatusOverLoad OBJECT-TYPE
+ SYNTAX INTEGER {
+ yes(14),
+ no(16) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Over Load"
+ ::= { upsThreePhaseFaultStatusGrp 4 }
+
+
+upsThreePhaseFaultStatusInverterOutputFail OBJECT-TYPE
+ SYNTAX INTEGER {
+ yes(14),
+ no(16) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Output Fail"
+ ::= { upsThreePhaseFaultStatusGrp 5 }
+
+
+upsThreePhaseFaultStatusOverTemperature OBJECT-TYPE
+ SYNTAX INTEGER {
+ yes(14),
+ no(16) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Over Temperature"
+ ::= { upsThreePhaseFaultStatusGrp 6 }
+
+
+upsThreePhaseFaultStatusShortCircuit OBJECT-TYPE
+ SYNTAX INTEGER {
+ yes(14),
+ no(16) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Short Circuit"
+ ::= { upsThreePhaseFaultStatusGrp 7 }
+
+
+upsThreePhaseRatingRectifierVoltage OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Rectifier Voltage"
+ ::= { upsThreePhaseRatingGrp 1 }
+
+
+upsThreePhaseRatingRectifierFrequency OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Rectifier Frequency"
+ ::= { upsThreePhaseRatingGrp 2 }
+
+
+upsThreePhaseRatingBypassVoltage OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Bypass Voltage"
+ ::= { upsThreePhaseRatingGrp 3 }
+
+
+upsThreePhaseRatingBypassFrequency OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Bypass Frequency"
+ ::= { upsThreePhaseRatingGrp 4 }
+
+
+upsThreePhaseRatingOutputVoltage OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Output Voltage"
+ ::= { upsThreePhaseRatingGrp 5 }
+
+
+upsThreePhaseRatingOutputFrequency OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Output Frequency"
+ ::= { upsThreePhaseRatingGrp 6 }
+
+
+upsThreePhaseRatingBatteryVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Battery Voltage"
+ ::= { upsThreePhaseRatingGrp 7 }
+
+
+upsThreePhaseRatingPower OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Power Rating"
+ ::= { upsThreePhaseRatingGrp 8 }
+
+
+-----------------------
+-----------------------
+
+upsEnvStatus OBJECT IDENTIFIER ::= { upsEnvironment 1 }
+
+upsEnvTemperature OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The ambient environment temperature."
+ ::= { upsEnvStatus 1 }
+
+
+upsEnvHumidity OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The environment humidity."
+ ::= { upsEnvStatus 2 }
+
+
+upsEnvOverTemperature OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Alarm dupsAlarmOverTemperature on when the environment
+ temperature over the value."
+ ::= { upsEnvSetting 1 }
+
+
+upsEnvOverHumidity OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Alarm dupsAlarmOverHumidity on when the environment
+ humidity over the value."
+ ::= { upsEnvSetting 3 }
+
+
+upsEnvSecurity1 OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(1),
+ abnormal(2) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Security status"
+ ::= { upsEnvStatus 5 }
+
+
+upsEnvSecurity2 OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(1),
+ abnormal(2) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Security status"
+ ::= { upsEnvStatus 6 }
+
+
+upsEnvSecurity3 OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(1),
+ abnormal(2) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Security status"
+ ::= { upsEnvStatus 7 }
+
+
+upsEnvSecurity4 OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(1),
+ abnormal(2) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Security status"
+ ::= { upsEnvStatus 8 }
+
+
+upsEnvSecurity5 OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(1),
+ abnormal(2) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Security status"
+ ::= { upsEnvStatus 9 }
+
+
+upsEnvSecurity6 OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(1),
+ abnormal(2) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Security status"
+ ::= { upsEnvStatus 10 }
+
+
+upsEnvSecurity7 OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(1),
+ abnormal(2) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Security status"
+ ::= { upsEnvStatus 11 }
+
+
+upsEnvWater OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(1),
+ abnormal(2) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Water status"
+ ::= { upsEnvStatus 3 }
+
+
+upsEnvSmoke OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(1),
+ abnormal(2) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Smoke status"
+ ::= { upsEnvStatus 4 }
+
+
+upsEnvSetting OBJECT IDENTIFIER ::= { upsEnvironment 2 }
+
+upsEnvUnderTemperature OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Alarm dupsAlarmUnderTemperature on when the environment
+ temperature below the value."
+ ::= { upsEnvSetting 2 }
+
+
+upsEnvUnderHumidity OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Alarm dupsAlarmUnderHumidity on when the environment
+ humidity below the value."
+ ::= { upsEnvSetting 4 }
+
+
+
+communicationLost TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "SEVERE: Communication to the UPS has been lost. Steps
+ to reestablish communication are in progress."
+ --#TYPE "PPC UPS: Communication failure"
+ --#SUMMARY "Communication to the UPS has been lost."
+ --#ARGUMENTS { }
+ --#SEVERITY CRITICAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 1
+
+
+
+upsOverLoad TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "SEVERE: The UPS has sensed a load greater than 100 percent
+ of its rated capacity."
+ --#TYPE "PPC UPS: UPS overload"
+ --#SUMMARY "The UPS has sensed a load greater than 100 percent of its rated capacity."
+ --#ARGUMENTS { }
+ --#SEVERITY CRITICAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 2
+
+
+
+upsDiagnosticsFailed TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "SEVERE: The UPS failed its internal diagnostic self-test."
+ --#TYPE "PPC UPS: Failed self-test"
+ --#SUMMARY "The UPS has failed its internal diagnostic self-test."
+ --#ARGUMENTS { }
+ --#SEVERITY CRITICAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 3
+
+
+
+upsDischarged TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "SEVERE: The UPS just started a runtime calibration
+ discharge. The UPS batteries are being discharged."
+ --#TYPE "PPC UPS: Deep discharge"
+ --#SUMMARY "The UPS has just started a runtime calibration discharge."
+ --#ARGUMENTS { }
+ --#SEVERITY CRITICAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 4
+
+
+
+upsOnBattery TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: The UPS has switched to battery backup power."
+ --#TYPE "PPC UPS: On battery"
+ --#SUMMARY "The UPS has switched to battery backup power."
+ --#ARGUMENTS { }
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 5
+
+
+
+boostOn TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: The UPS has enabled Boost."
+ --#TYPE "PPC UPS: SmartBoost"
+ --#SUMMARY "The UPS has enabled Boost."
+ --#ARGUMENTS { }
+ --#SEVERITY MINOR
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 6
+
+
+
+lowBattery TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "SEVERE: The UPS batteries are low and will soon be exhausted.
+ If utility power is not restored the UPS will put itself
+ to 'sleep' and immediately cut power to the load."
+ --#TYPE "PPC UPS: Low battery"
+ --#SUMMARY "The UPS batteries are low and will soon be exhausted."
+ --#ARGUMENTS { }
+ --#SEVERITY CRITICAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 7
+
+
+
+communicationEstablished TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "INFORMATION: Communication with the UPS has been
+ established."
+ --#TYPE "PPC UPS: Communication established"
+ --#SUMMARY "Communication with the UPS has been established."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 8
+
+
+
+powerRestored TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "INFORMATION: Utility power has been restored."
+ --#TYPE "PPC UPS: Utility restored"
+ --#SUMMARY "Normal power has been restored to the UPS."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 9
+
+
+
+upsDiagnosticsPassed TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "INFORMATION: The UPS passed its internal self-test."
+ --#TYPE "PPC UPS: Passed self-test"
+ --#SUMMARY "The UPS has passed its internal self-test."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 10
+
+
+
+returnFromLowBattery TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "INFORMATION: The UPS has returned from a low battery
+ condition."
+ --#TYPE "PPC UPS: Battery normal"
+ --#SUMMARY "The UPS has returned from a low battery condition."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 11
+
+
+
+upsTurnedOff TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: The UPS has been turned 'off' by the
+ management station."
+ --#TYPE "PPC UPS: Switching off"
+ --#SUMMARY "The UPS is being switched off by a management station."
+ --#ARGUMENTS { }
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 12
+
+
+
+upsSleeping TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: The UPS is entering 'sleep' mode. Power
+ to the load will be cut off."
+ --#TYPE "PPC UPS: Going to sleep"
+ --#SUMMARY "The UPS is going into sleep mode."
+ --#ARGUMENTS { }
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 13
+
+
+
+upsWokeUp TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "INFORMATION: The UPS woke up from 'sleep' mode. Power
+ to the load has been restored."
+ --#TYPE "PPC UPS: Wake up"
+ --#SUMMARY "The UPS has woke up from sleep mode."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 14
+
+
+
+upsRebootStarted TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: The UPS has started its reboot sequence. After
+ the specified delay the UPS will perform a reboot."
+ --#TYPE "PPC UPS: Starting reboot"
+ --#SUMMARY "The UPS has started its reboot sequence."
+ --#ARGUMENTS { }
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 15
+
+
+envOverTemperature TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: The environment temperature exceed the normal value."
+ ::= 16
+
+
+envTemperatureNormal TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "INFORMATION: The environment temperature is normal."
+ ::= 17
+
+
+envOverHumidity TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: The environment humidity exceed the normal value."
+ ::= 18
+
+
+envHumidityNormal TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "INFORMATION: The environment humidity is normal."
+ ::= 19
+
+
+envSmokeAbnormal TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: Smoke is abnormal."
+ ::= 20
+
+
+envWaterAbnormal TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: Water is abnormal."
+ ::= 21
+
+
+envSecurityAbnormal TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: Security is abnormal."
+ ::= 22
+
+
+--envSmokeNormal TRAP-TYPE
+-- ENTERPRISE ppc
+-- DESCRIPTION
+-- "INFORMATION: Smoke is normal."
+-- ::= 23
+
+
+envWaterNormal TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "INFORMATION: Water is normal."
+ ::= 24
+
+
+--envSecurityNormal TRAP-TYPE
+-- ENTERPRISE ppc
+-- DESCRIPTION
+-- "INFORMATION: Security is normal."
+-- ::= 25
+
+
+envGasAbnormal TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: Gas Alarm"
+ ::= 26
+
+
+upsTemp TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: UPS Temperature Overrun"
+ ::= 27
+
+
+upsLoadNormal TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: UPS Load Normal"
+ ::= 28
+
+
+upsTempNormal TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: UPS temperature Normal"
+ ::= 29
+
+
+envUnderTemperature TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: The environment temperature below the normal value."
+ ::= 30
+
+
+envUnderHumidity TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: The environment humidity below the normal value."
+ ::= 31
+
+
+upsBypass TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: The UPS is entering 'bypass' mode."
+ ::= 32
+
+
+envSecurity1 TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: Security1 Alarm."
+ ::= 33
+
+
+envSecurity2 TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: Security2 Alarm."
+ ::= 34
+
+
+envSecurity3 TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: Security3 Alarm."
+ ::= 35
+
+
+envSecurity4 TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: Security4 Alarm."
+ ::= 36
+
+
+envSecurity5 TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: Security5 Alarm."
+ ::= 37
+
+
+envSecurity6 TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: Security6 Alarm."
+ ::= 38
+
+
+envSecurity7 TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: Security7 Alarm."
+ ::= 39
+
+
+--envSecurity1Return TRAP-TYPE
+-- ENTERPRISE ppc
+-- DESCRIPTION
+-- "WARNING: Security1 Normal."
+-- ::= 40
+
+
+--envSecurity2Return TRAP-TYPE
+-- ENTERPRISE ppc
+-- DESCRIPTION
+-- "WARNING: Security2 Normal"
+-- ::= 41
+
+
+--envSecurity3Return TRAP-TYPE
+-- ENTERPRISE ppc
+-- DESCRIPTION
+-- "WARNING: Security3 Normal."
+-- ::= 42
+
+
+--envSecurity4Return TRAP-TYPE
+-- ENTERPRISE ppc
+-- DESCRIPTION
+-- "WARNING: Security4 Normal."
+-- ::= 43
+
+
+--envSecurity5Return TRAP-TYPE
+-- ENTERPRISE ppc
+-- DESCRIPTION
+-- "WARNING: Security5 Normal."
+-- ::= 44
+
+
+--envSecurity6Return TRAP-TYPE
+-- ENTERPRISE ppc
+-- DESCRIPTION
+-- "WARNING: Security6 Normal."
+-- ::= 45
+
+
+--envSecurity7Return TRAP-TYPE
+-- ENTERPRISE ppc
+-- DESCRIPTION
+-- "WARNING: Security7 Normal."
+-- ::= 46
+
+
+upsRecroterror TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: Rectifier Rotation Error"
+ ::= 47
+
+
+upsBypassFreFail TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: Bypass Frequency Fail"
+ ::= 48
+
+
+upsBypassacnormal TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: Bypass AC Normal"
+ ::= 49
+
+
+upsBypassacabnormal TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: Bypass AC Abnormal"
+ ::= 50
+
+
+upsTest TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: UPS Test"
+ ::= 51
+
+
+upsScheduleShutdown TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: UPS Schedule Shutdown"
+ ::= 52
+
+upsBypassReturn TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "The UPS return from Bypass Mode"
+ ::= 53
+
+upsShortCircuitShutdown TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "The UPS Short Circuit Shutdown"
+ ::= 54
+
+upsInverterOutputFailShutdown TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "The UPS Inverter Output Fail Shutdown"
+ ::= 55
+
+upsBypassBreadkerOnShutdown TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "The UPS Manual Bypass Breaker on Shutdown"
+ ::= 56
+
+upsHighDCShutdown TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "The UPS High DC Shutdown"
+ ::= 57
+
+upsEmergencyStop TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "The UPS Emergency Stop"
+ ::= 58
+
+upsInverterMode TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "The UPS Static Switch in Inverter Mode"
+ ::= 59
+
+upsBypassMode TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "The UPS Static Switch in Bypass Mode"
+ ::= 60
+
+upsOverTemperatureShutdown TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "The UPS Over Temperature Shutdown"
+ ::= 61
+
+upsOverLoadShutdown TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "The UPS Overload Shutdown"
+ ::= 62
+
+upsCapacityUnderrun TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "The UPS Capacity Underrun"
+ ::= 63
+
+upsCapacityNormal TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "The UPS Capacity Normal"
+ ::= 64
+
+upsLowBatteryShutdown TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "The UPS Low Battery Shutdown"
+ ::= 67
+
+END
diff --git a/mibs/logmaster/UPSMATE-MIB b/mibs/logmaster/UPSMATE-MIB
new file mode 100644
index 0000000000..55f4a2a060
--- /dev/null
+++ b/mibs/logmaster/UPSMATE-MIB
@@ -0,0 +1,2367 @@
+--PPC-MIB { iso(1) org(3) dod(6) internet(1) private(4)
+-- enterprises(1) ppc(935) }
+-- Title: PPC TOP LEVEL MIB
+-- Date: January 07, 1994 Version 1.00
+--
+-- Date: January 17, 1994 Version 1.01
+--
+-- Date: July 14, 1994 Version 1.02
+--
+-- Date: May 16, 2003 Version 2.00
+
+XPPC-MIB DEFINITIONS ::= BEGIN
+
+IMPORTS
+ TRAP-TYPE
+ FROM RFC-1215
+ DisplayString
+ FROM RFC1213-MIB
+ OBJECT-TYPE
+ FROM RFC-1212
+ enterprises,
+ IpAddress
+ FROM RFC1155-SMI;
+
+
+ppc OBJECT IDENTIFIER
+ ::= { enterprises 935 }
+
+products OBJECT IDENTIFIER
+ ::= { ppc 1 }
+
+ppcmgmt OBJECT IDENTIFIER
+ ::= { ppc 2 }
+
+hardware OBJECT IDENTIFIER
+ ::= { products 1 }
+
+mconfig OBJECT IDENTIFIER
+ ::= { ppcmgmt 1 }
+
+ups OBJECT IDENTIFIER
+ ::= { hardware 1 }
+
+upsIdentp OBJECT IDENTIFIER
+ ::= { ups 1 }
+
+upsBatteryp OBJECT IDENTIFIER
+ ::= { ups 2 }
+
+upsInputp OBJECT IDENTIFIER
+ ::= { ups 3 }
+
+upsOutputp OBJECT IDENTIFIER
+ ::= { ups 4 }
+
+upsConfigp OBJECT IDENTIFIER
+ ::= { ups 5 }
+
+upsControlp OBJECT IDENTIFIER
+ ::= { ups 6 }
+
+upsTestp OBJECT IDENTIFIER
+ ::= { ups 7 }
+
+upsThreePhase OBJECT IDENTIFIER
+ ::= { ups 8 }
+
+upsEnvironment OBJECT IDENTIFIER
+ ::= { ups 9 }
+
+upsBaseIdent OBJECT IDENTIFIER
+ ::= { upsIdentp 1 }
+
+upsSmartIdent OBJECT IDENTIFIER
+ ::= { upsIdentp 2 }
+
+upsBaseBattery OBJECT IDENTIFIER
+ ::= { upsBatteryp 1 }
+
+upsSmartBattery OBJECT IDENTIFIER
+ ::= { upsBatteryp 2 }
+
+upsBaseInput OBJECT IDENTIFIER
+ ::= { upsInputp 1 }
+
+upsSmartInput OBJECT IDENTIFIER
+ ::= { upsInputp 2 }
+
+upsBaseOutput OBJECT IDENTIFIER
+ ::= { upsOutputp 1 }
+
+upsSmartOutput OBJECT IDENTIFIER
+ ::= { upsOutputp 2 }
+
+upsBaseConfig OBJECT IDENTIFIER
+ ::= { upsConfigp 1 }
+
+upsSmartConfig OBJECT IDENTIFIER
+ ::= { upsConfigp 2 }
+
+upsBaseControl OBJECT IDENTIFIER
+ ::= { upsControlp 1 }
+
+upsSmartControl OBJECT IDENTIFIER
+ ::= { upsControlp 2 }
+
+upsBaseTest OBJECT IDENTIFIER
+ ::= { upsTestp 1 }
+
+upsSmartTest OBJECT IDENTIFIER
+ ::= { upsTestp 2 }
+
+upsThreePhaseBatteryGrp OBJECT IDENTIFIER
+ ::= { upsThreePhase 1 }
+
+upsThreePhaseInputGrp OBJECT IDENTIFIER
+ ::= { upsThreePhase 2 }
+
+upsThreePhaseOutputGrp OBJECT IDENTIFIER
+ ::= { upsThreePhase 3 }
+
+upsThreePhaseBypassGrp OBJECT IDENTIFIER
+ ::= { upsThreePhase 4 }
+
+upsThreePhaseDCandRectifierStatusGrp OBJECT IDENTIFIER
+ ::= { upsThreePhase 5 }
+
+upsThreePhaseUPSStatusGrp OBJECT IDENTIFIER
+ ::= { upsThreePhase 6 }
+
+upsThreePhaseFaultStatusGrp OBJECT IDENTIFIER
+ ::= { upsThreePhase 7 }
+
+upsThreePhaseRatingGrp OBJECT IDENTIFIER
+ ::= { upsThreePhase 8 }
+
+-- object types
+-- the ppcmgmt group
+-- the mconfig group
+
+mconfigTrapsReceiversNum OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of managers to send traps to."
+ ::= { mconfig 1 }
+
+
+mconfigTrapsReceiversTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF MconfigTrapsReceiversEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of managers to send traps to. The number of
+ entries is given by the value of mconfigNumTrapReceivers"
+ ::= { mconfig 2 }
+
+
+mconfigTrapsReceiversEntry OBJECT-TYPE
+ SYNTAX MconfigTrapsReceiversEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The managers to send traps to."
+ INDEX {
+ trapsIndex }
+ ::= { mconfigTrapsReceiversTable 1 }
+
+
+MconfigTrapsReceiversEntry ::= SEQUENCE {
+ trapsIndex INTEGER,
+ trapsReceiverAddr IpAddress,
+ receiverCommunityString DisplayString,
+ severityLevel INTEGER,
+ receiverAccept INTEGER }
+
+
+trapsIndex OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index to a trap receiver entry."
+ ::= { mconfigTrapsReceiversEntry 1 }
+
+
+trapsReceiverAddr OBJECT-TYPE
+ SYNTAX IpAddress
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The IP address of the manager to send a trap to."
+ ::= { mconfigTrapsReceiversEntry 2 }
+
+
+receiverCommunityString OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The community name to use in the trap when
+ sent to the manager."
+ ::= { mconfigTrapsReceiversEntry 3 }
+
+
+severityLevel OBJECT-TYPE
+ SYNTAX INTEGER {
+ information(1),
+ warning(2),
+ severe(3) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The severity threshold of traps to send to the manager.
+ traps are labeled in severity as informational(1), warning(2),
+ severe(3). Only traps of equal or greater severity than
+ this value are sent to the manager."
+ ::= { mconfigTrapsReceiversEntry 4 }
+
+
+receiverAccept OBJECT-TYPE
+ SYNTAX INTEGER {
+ yes(1),
+ no(2) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "An entry will become active if yes, and will
+ be deleted if no."
+ ::= { mconfigTrapsReceiversEntry 5 }
+
+
+-- the ups group
+-- the upsBaseIdent group
+
+upsBaseIdentModel OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The UPS model name (e.g. 'Intelligent 8000E 900VA')."
+ ::= { upsBaseIdent 1 }
+
+
+upsBaseIdentUpsName OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "An 8 byte ID string identifying the UPS. This object
+ can be set by the administrator."
+ ::= { upsBaseIdent 2 }
+
+
+-- the upsSmartIdent group
+
+upsSmartIdentFirmwareRevision OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The firmware revision of the UPS system."
+ ::= { upsSmartIdent 1 }
+
+
+upsSmartIdentDateOfManufacture OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The date when the UPS was manufactured in mm/dd/yy format."
+ ::= { upsSmartIdent 2 }
+
+
+upsSmartIdentUpsSerialNumber OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "An 8-character string identifying the serial number of
+ the UPS internal microprocessor. This number is set at
+ the factory. NOTE: This number does NOT correspond to
+ the serial number on the rear of the UPS."
+ ::= { upsSmartIdent 3 }
+
+
+upsSmartIdentAgentFirmwareRevision OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The firmware revision of the UPS SNMP Proxy agent."
+ ::= { upsSmartIdent 4 }
+
+
+-- the upsBaseBattery group
+
+upsBaseBatteryStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(1),
+ batteryNormal(2),
+ batteryLow(3) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The status of the UPS batteries. A batteryLow(3)
+ value indicates the UPS will be unable to sustain the
+ current load, and its services will be lost if power is
+ not restored. The amount of run time in reserve at the
+ time of low battery can be configured by the
+ upsSmartConfigLowBatteryRunTime."
+ ::= { upsBaseBattery 1 }
+
+
+upsBaseBatteryTimeOnBattery OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The elapsed time in seconds since the UPS has switched
+ to battery power."
+ ::= { upsBaseBattery 2 }
+
+
+upsBaseBatteryLastReplaceDate OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The date when the UPS system's batteries were last replaced
+ in mm/dd/yy format. For UPS models, this value is originally
+ set in the factory. When the UPS batteries are replaced,
+ this value should be reset by the administrator."
+ ::= { upsBaseBattery 3 }
+
+
+-- the upsSmartBattery group
+
+upsSmartBatteryCapacity OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The remaining battery capacity expressed in
+ percent of full capacity."
+ ::= { upsSmartBattery 1 }
+
+
+upsSmartBatteryVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current battery voltage expressed in 1/10 VDC."
+ ::= { upsSmartBattery 2 }
+
+
+upsSmartBatteryTemperature OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current internal UPS temperature expressed in tenths of
+ a Celsius degree."
+ ::= { upsSmartBattery 3 }
+
+
+upsSmartBatteryRunTimeRemaining OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The UPS battery run time remaining before battery
+ exhaustion, in seconds."
+ ::= { upsSmartBattery 4 }
+
+
+upsSmartBatteryReplaceIndicator OBJECT-TYPE
+ SYNTAX INTEGER {
+ noBatteryNeedsReplacing(1),
+ batteryNeedsReplacing(2) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Indicates whether the UPS batteries need replacing."
+ ::= { upsSmartBattery 5 }
+
+
+upsSmartBatteryFullChargeVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The fully charged battery voltage of the battery system
+ used in the UPS, expressed in tenths of a volt."
+ ::= { upsSmartBattery 6 }
+
+
+upsSmartBatteryCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current battery current expressed in percent of
+ maximum current."
+ ::= { upsSmartBattery 7 }
+
+
+-- the upsBaseInput group
+
+upsBaseInputPhase OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current AC input phase."
+ ::= { upsBaseInput 1 }
+
+
+-- the upsSmartInput group
+
+upsSmartInputLineVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current utility line voltage in 1/10 VAC."
+ ::= { upsSmartInput 1 }
+
+
+upsSmartInputMaxLineVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum utility line voltage in 1/10 VAC over the
+ previous 1 minute period."
+ ::= { upsSmartInput 2 }
+
+
+upsSmartInputMinLineVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The minimum utility line voltage in 1/10 VAC over the
+ previous 1 minute period."
+ ::= { upsSmartInput 3 }
+
+
+upsSmartInputFrequency OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current input frequency to the UPS system in 1/10 Hz."
+ ::= { upsSmartInput 4 }
+
+
+upsSmartInputLineFailCause OBJECT-TYPE
+ SYNTAX INTEGER {
+ noTransfer(1),
+ highLineVoltage(2),
+ brownout(3),
+ blackout(4),
+ smallMomentarySag(5),
+ deepMomentarySag(6),
+ smallMomentarySpike(7),
+ largeMomentarySpike(8) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The reason for the occurrence of the last transfer
+ to UPS battery power. The variable is set to
+ noTransfer(1) if there is no transfer yet. The variable
+ is set to highLineVoltage(2) if the transfer to battery is
+ caused by an over voltage greater than the high transfer
+ voltage. The variable is set to brownout(3) if the duration
+ of the outage is greater than five seconds and the line
+ voltage is between 40 percent of the rated output voltage and
+ the low transfer voltage. The variable is set to blackout(4)
+ if the duration of the outage is greater than five seconds and
+ the line voltage is between 40 percent of the rated output voltage
+ and ground. The variable is set to smallMomentarySag(5)
+ if the duration of the outage is less than five seconds and
+ the line voltage is between 40 percent of the rated output voltage
+ and the low transfer voltage. The variable is set to
+ deepMomentarySag(6) if the duration of the outage is less
+ than five seconds and the line voltage is between 40 percent of the
+ rated output voltage and ground."
+ ::= { upsSmartInput 5 }
+
+
+-- the upsBaseOutput group
+
+upsBaseOutputStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(1),
+ onLine(2),
+ onBattery(3),
+ onBoost(4),
+ sleeping(5),
+ onBypass(6),
+ rebooting(7),
+ standBy(8),
+ onBuck(9) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current state of the UPS. If the UPS is unable
+ to determine the state of the UPS this variable is set
+ to unknown(1)."
+ ::= { upsBaseOutput 1 }
+
+
+upsBaseOutputPhase OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current output phase."
+ ::= { upsBaseOutput 2 }
+
+
+-- the upsSmartOutput group
+
+upsSmartOutputVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The output voltage of the UPS system in 1/10 VAC."
+ ::= { upsSmartOutput 1 }
+
+
+upsSmartOutputFrequency OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current output frequency of the UPS system in 1/10 Hz."
+ ::= { upsSmartOutput 2 }
+
+
+upsSmartOutputLoad OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The current UPS load expressed in percent
+ of rated capacity."
+ ::= { upsSmartOutput 3 }
+
+
+-- the upsBaseConfig group
+
+upsBaseConfigNumDevices OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The number of devices that are plugged into the UPS."
+ ::= { upsBaseConfig 1 }
+
+
+upsBaseConfigDeviceTable OBJECT-TYPE
+ SYNTAX SEQUENCE OF UpsBaseConfigDeviceEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "A list of devices that are plugged into the UPS. The
+ number of entries is given by the value of
+ upsBaseConfigNumDevices."
+ ::= { upsBaseConfig 2 }
+
+
+upsBaseConfigDeviceEntry OBJECT-TYPE
+ SYNTAX UpsBaseConfigDeviceEntry
+ ACCESS not-accessible
+ STATUS mandatory
+ DESCRIPTION
+ "The devices plugged in to the UPS."
+ INDEX {
+ indexOfDevice }
+ ::= { upsBaseConfigDeviceTable 1 }
+
+
+UpsBaseConfigDeviceEntry ::= SEQUENCE {
+ indexOfDevice INTEGER,
+ nameOfDevice DisplayString,
+ vaRatingOfDevice INTEGER,
+ deviceAccept INTEGER }
+
+
+indexOfDevice OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The index of the device that is plugged into the UPS."
+ ::= { upsBaseConfigDeviceEntry 1 }
+
+
+nameOfDevice OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The name/description of the device plugged into the UPS."
+ ::= { upsBaseConfigDeviceEntry 2 }
+
+
+vaRatingOfDevice OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The volt-amp rating of the device plugged into the UPS."
+ ::= { upsBaseConfigDeviceEntry 3 }
+
+
+deviceAccept OBJECT-TYPE
+ SYNTAX INTEGER {
+ yes(1),
+ no(2) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "An entry is added if yes, the entry is deleted if no."
+ ::= { upsBaseConfigDeviceEntry 4 }
+
+
+-- the upsSmartConfig group
+
+upsSmartConfigRatedOutputVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The nominal output voltage from the UPS in 1/10 VAC.
+ Possible values are 1000, 1200, 2080, 2200, 2250, 2300
+ and 2400.
+
+ NOTE: Only units that are 2200, 2250, 2300 and 2400 can
+ be changed. Allowable values are 2200, 2250, 2300 and
+ 2400.
+
+ For these adjustable units, if a value other than
+ a supported value is provided in a set request, the
+ UPS interprets it as the next lower acceptable value.
+ If the provided value is lower than the lowest acceptable
+ value, the lowest acceptable value is used."
+ ::= { upsSmartConfig 1 }
+
+
+upsSmartConfigHighTransferVolt OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The maximum line voltage in 1/10 VAC allowed before the
+ UPS system transfers to battery backup.
+
+ Allowed value depend on the UPS used:
+ 120 Volt units allow settings of 1290, 1320, 1350, 1380.
+ 100 Volt units allow settings of 1080, 1100, 1120, 1140.
+ 230 Volt units allow settings of 2530, 2640, 2710, 2800.
+ 208 Volt units allow settings of 2240, 2290, 2340, 2390.
+
+ If a value other than a supported value is provided in a
+ set request, the UPS interprets it as the next lower
+ acceptable value. If the provided value is lower than
+ the lowest acceptable value, the lowest acceptable
+ value is used."
+ ::= { upsSmartConfig 2 }
+
+
+upsSmartConfigLowTransferVolt OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The minimum line voltage in 1/10 VAC allowed before the
+ UPS system transfers to battery backup.
+
+ Allowable values depend on the UPS used:
+ 120 Volt units allow settings of 970, 1000, 1030, 1060.
+ 100 Volt units allow settings of 810, 830, 850, 870.
+ 230 Volt units allow settings of 1880, 1960, 2040, 2080.
+ 208 Volt units allow settings of 1680, 1720, 1770, 1820.
+
+ If a value other than a supported value is provided in a
+ set request, the UPS interprets it as a the next higher
+ acceptable value. If the provided value is higher than
+ the highest acceptable value, the highest acceptable
+ value is used."
+ ::= { upsSmartConfig 3 }
+
+
+upsSmartConfigAlarm OBJECT-TYPE
+ SYNTAX INTEGER {
+ timed(1),
+ atLowBattery(2),
+ never(3) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "A flag indicating how the UPS should handle audible line fail
+ alarms."
+ ::= { upsSmartConfig 4 }
+
+
+upsSmartConfigAlarmTimer OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The time in seconds after initial line failure at which the
+ UPS begins emitting audible alarms (beeping). This timer is
+ observerd only if the value of extControlAlarm is timed(2).
+ Allowed values are 0 or 30 seconds.
+
+ If a value other than a supported value is provided in a
+ set request, the UPS interprets it as a the next lower
+ acceptable value. If the provided value is lower than
+ the lowest acceptable value, the lowest acceptable
+ value is used."
+ ::= { upsSmartConfig 5 }
+
+
+upsSmartConfigMinReturnCapacity OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The minimum battery capacity as a percent of full capacity
+ required before the UPS will return from a low battery
+ shutdown condition. In other words, the UPS will not
+ re-energize the output until the battery capacity is equal
+ to this value. Allowed values are 0, 10, 25, or 90 percent.
+
+ If a value other than a supported value is provided in a
+ set request, the UPS interprets it as a the next higher
+ acceptable value. If the provided value is higher than
+ the highest acceptable value, the highest acceptable
+ value is used."
+ ::= { upsSmartConfig 6 }
+
+
+upsSmartConfigSensitivity OBJECT-TYPE
+ SYNTAX INTEGER {
+ auto(1),
+ low(2),
+ medium(3),
+ high(4) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The sensitivity of the UPS to utility line abnormalities
+ or noises."
+ ::= { upsSmartConfig 7 }
+
+
+upsSmartConfigLowBatteryRunTime OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The desired run time in seconds once the low battery
+ condition is reached. Allowed values are 120, 300, 420,
+ or 600 seconds. During this time the UPS will produce a
+ constant warning tone which can not be disabled.
+
+ If a value other than a supported value is provided in a
+ set request, the UPS interprets it as a the next higher
+ acceptable value. If the provided value is higher than
+ the highest acceptable value, the highest acceptable
+ value is used."
+ ::= { upsSmartConfig 8 }
+
+
+upsSmartConfigReturnDelay OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The delay in seconds after utility line power returns
+ before the UPS will turn on. This value is also used
+ when the UPS comes out of a reboot and before the UPS
+ wakes up from 'sleep' mode. Allowed values are 0, 60,
+ 180 and 300 seconds.
+
+ If a value other than a supported value is provided in a
+ set request, the UPS interprets it as a the next higher
+ acceptable value. If the provided value is higher than
+ the highest acceptable value, the highest acceptable
+ value is used."
+ ::= { upsSmartConfig 9 }
+
+
+upsSmartConfigShutoffDelay OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The delay in seconds the UPS remains on after being told
+ to turn off. Allowed values are 12, 18, 24, 30, 36, 42,
+ 48, 54, 60, 120, 180, 240, 300, 360, 420, 480, 540, and
+ 600 seconds.
+
+ If a value other than a supported value is provided in a
+ set request, the UPS interprets it as next higher acceptable
+ value. If the provided value is higher than the highest
+ acceptable value, the highest acceptable value is used."
+ ::= { upsSmartConfig 10 }
+
+
+upsSmartConfigUpsSleepTime OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The time in minutes for the UPS to go to 'sleep' when
+ instructed. When in sleep mode, the UPS will not provide
+ output power regardless of the input line state. Once the
+ specified time has elapsed, output power will be restored.
+
+ This is a configuration setting. The UPS will not go to
+ sleep until told to do so by the manager from a management
+ station.
+
+ Any input value is allowed, however the UPS only recognizes
+ 0 - 9999 minutes in one minute increments.
+
+ If the provided value is higher than the highest acceptable
+ value, the highest acceptable value is used."
+ ::= { upsSmartConfig 11 }
+
+
+upsSmartConfigSetEEPROMDefaults OBJECT-TYPE
+ SYNTAX INTEGER {
+ noSetEEPROMDefaults(1),
+ setEEPROMDefaults(2) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "WRITE: Resets the UPS EEPROM variables to default values.
+ READ: returns 0"
+ ::= { upsSmartConfig 12 }
+
+
+-- the upsBaseControl group
+
+upsBaseControlConserveBattery OBJECT-TYPE
+ SYNTAX INTEGER {
+ noTurnOffUps(1),
+ turnUpsOffToConserveBattery(2),
+ turnUpsOffToConserveBatteryDelay(3) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this variable to turnUpsOffToConserveBattery(2)
+ causes a UPS on battery to be put into 'sleep' mode immediately.
+ The (10) means suspending time(10 minutes) before turn off UPS.
+ UPS will turn back on when utility power is restored.
+ Attempting to turn off a UPS that is not on battery will
+ result in a badValue error.
+
+ Setting this value to noTurnOffUps(1) has no
+ effect.
+
+ The value noTurnOffUps(1) will always be returned
+ when the variable is read."
+ ::= { upsBaseControl 1 }
+
+
+-- the upsSmartControl group
+
+upsSmartControlUpsOff OBJECT-TYPE
+ SYNTAX INTEGER {
+ noTurnUpsOff(1),
+ turnUpsOff(2) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this variable to turnUpsOff(2) causes
+ the UPS to shut off. When in this state, the UPS
+ will not provide output power regardless of the input
+ line state. The on/off switch on the UPS
+ must be toggled for the UPS to return to operation.
+
+ Setting this value to noTurnUpsOff(1) has no
+ effect.
+
+ The value noTurnUpsOff(1) will always be returned
+ when the variable is read."
+ ::= { upsSmartControl 1 }
+
+
+upsSmartControlRebootUps OBJECT-TYPE
+ SYNTAX INTEGER {
+ noRebootUps(1),
+ rebootUps(2) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this variable to rebootUps(2) causes the
+ UPS to shut off and turn back on.
+
+ Setting this value to noRebootUps(1) has no effect.
+
+ The value noRebootUps(1) will always be returned
+ when the variable is read."
+ ::= { upsSmartControl 2 }
+
+
+upsSmartControlUpsSleep OBJECT-TYPE
+ SYNTAX INTEGER {
+ noPutUpsToSleep(1),
+ putUpsToSleep(2) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this variable to putUpsToSleep(2) causes
+ the UPS to go to sleep for the time specified by
+ upsSmartConfigUpsSleepTime.
+
+ When in sleep mode, the UPS will not provide output
+ power regardless of the input line state. Once the
+ specified time has elapsed, output power will be
+ restored.
+
+ Setting this value to noPutUpsToSleep(1) has no
+ effect.
+
+ The value noPutUpsToSleep(1) will always be returned
+ when the variable is read."
+ ::= { upsSmartControl 3 }
+
+
+upsSmartControlSimulatePowerFail OBJECT-TYPE
+ SYNTAX INTEGER {
+ noSimulatePowerFailure(1),
+ simulatePowerFailure(2) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this variable to simulatePowerFailure(2) causes
+ the UPS switch to battery power.
+
+ Setting this value to noSimulatePowerFailure(1) has no
+ effect.
+
+ The value noSimulatePowerFailure(1) will always be returned
+ when the variable is read."
+ ::= { upsSmartControl 4 }
+
+
+upsSmartControlFlashAndBeep OBJECT-TYPE
+ SYNTAX INTEGER {
+ noFlashAndBeep(1),
+ flashAndBeep(2) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "UPS to identify itself by lighting all indicators
+ and beeping.
+
+ Setting this variable to FlashAndBeep(2) causes
+ the UPS lights all panel indicators and beeps.
+
+ Setting this value to noFlashAndBeep(1) has no
+ effect.
+
+ The value noFlashAndBeep(1) will always be returned
+ when the variable is read."
+ ::= { upsSmartControl 5 }
+
+
+upsSmartControlTurnOnUpsLoad OBJECT-TYPE
+ SYNTAX INTEGER {
+ noUpsSmartControlTurnOnUpsLoad(1),
+ upsSmartControlTurnOnUpsLoad(2) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this variable to upsSmartControlTurnOnUpsLoad(2)
+ causes the UPS switch back to utility power if utility
+ power is present.
+
+ Setting this value to noUpsSmartControlTurnOnUpsLoad(1)
+ has no effect.
+
+ The value noUpsSmartControlTurnOnUpsLoad(1) will always
+ be returned when the variable is read."
+ ::= { upsSmartControl 6 }
+
+
+-- the upsBaseTest group
+-- the upsSmartTest group
+
+upsSmartTestDiagnosticSchedule OBJECT-TYPE
+ SYNTAX INTEGER {
+ unknown(1),
+ biweekly(2),
+ weekly(3),
+ never(4) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "The UPS system's automatic battery test schedule."
+ ::= { upsSmartTest 1 }
+
+
+upsSmartTestDiagnostics OBJECT-TYPE
+ SYNTAX INTEGER {
+ noTestDiagnostics(1),
+ testDiagnostics(2) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this variable to testDiagnostics(2) causes
+ the UPS to perform a diagnostic self test.
+
+ Setting this value to noTestDiagnostics(1) has no
+ effect.
+
+ The value noTestDiagnostics(1) will always be returned
+ when the variable is read."
+ ::= { upsSmartTest 2 }
+
+
+upsSmartTestDiagnosticsResults OBJECT-TYPE
+ SYNTAX INTEGER {
+ ok(1),
+ failed(2),
+ invalidTest(3),
+ testInProgress(4) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The results of the last UPS diagnostics test performed."
+ ::= { upsSmartTest 3 }
+
+
+upsSmartTestLastDiagnosticsDate OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The date the last UPS diagnostics test was performed in
+ mm/dd/yy format."
+ ::= { upsSmartTest 4 }
+
+
+upsSmartTestIndicators OBJECT-TYPE
+ SYNTAX INTEGER {
+ noTestIndicators(1),
+ testIndicators(2) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this variable to testIndicators(2) causes
+ the UPS to perform a front panel indicator (lights) test.
+
+ Setting this value to noTestIndicators(1) has no effect.
+
+ The value noTestIndicators(1) will always be returned
+ when the variable is read."
+ ::= { upsSmartTest 5 }
+
+
+upsSmartTestRuntimeCalibration OBJECT-TYPE
+ SYNTAX INTEGER {
+ noPerformCalibration(1),
+ performCalibration(2),
+ cancelCurrentCalibration(3) }
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Setting this variable to performCalibration(2) causes
+ the UPS to discharge to calibrate the UPS.
+ The test will only start if the battery capacity is 100 percent.
+ The test runs until capacity is less than 25 percent.
+
+ Setting this variable to cancelCurrentCalibration(3)
+ after setting performCalibration(2) will cancel the
+ current discharge.
+
+ Setting this variable to noPerformCalibration(1)
+ will have no effect.
+
+ The value noPerformCalibration(1) will always be returned
+ when the variable is read.
+
+ The result of the calibration will be saved in
+ upsSmartTestCalibrationResult."
+ ::= { upsSmartTest 6 }
+
+
+upsSmartTestCalibrationResults OBJECT-TYPE
+ SYNTAX INTEGER {
+ ok(1),
+ invalidTest(2),
+ calibrationInProgress(3) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The results of the last runtime calibration.
+
+ Value ok(1) means a successful runtime calibration.
+
+ Value invalidTest(2) indicates last calibration did
+ not take place since the battery capacity was below
+ 100 percent.
+
+ Value calibrationInProgress(3) means a calibration
+ is occurring now."
+ ::= { upsSmartTest 7 }
+
+
+upsSmartTestCalibrationDate OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The date the last UPS runtime calibration was
+ performed in mm/dd/yy format."
+ ::= { upsSmartTest 8 }
+
+
+-----------------------
+--ups ThreePhase group-
+-----------------------
+upsThreePhaseBatteryVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Battery Voltage"
+ ::= { upsThreePhaseBatteryGrp 1 }
+
+
+upsThreePhaseBatteryCapacityPercentage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Battery Capacity Percentage"
+ ::= { upsThreePhaseBatteryGrp 2 }
+
+
+upsThreePhaseBatteryTimeRemain OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Battery Time Remain (unit is Minute)"
+ ::= { upsThreePhaseBatteryGrp 3 }
+
+
+upsThreePhaseBatteryCurrent OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Battery Electric Current"
+ ::= { upsThreePhaseBatteryGrp 4 }
+
+
+upsThreePhaseBatteryTemperature OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Battery Temperature"
+ ::= { upsThreePhaseBatteryGrp 5 }
+
+
+upsThreePhaseInputFrequency OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Input Frequency"
+ ::= { upsThreePhaseInputGrp 1 }
+
+
+upsThreePhaseInputVoltageR OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Input VoltageR"
+ ::= { upsThreePhaseInputGrp 2 }
+
+
+upsThreePhaseInputVoltageS OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Input VoltageS"
+ ::= { upsThreePhaseInputGrp 3 }
+
+
+upsThreePhaseInputVoltageT OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Input VoltageT"
+ ::= { upsThreePhaseInputGrp 4 }
+
+
+upsThreePhaseOutputFrequency OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Output Frequency"
+ ::= { upsThreePhaseOutputGrp 1 }
+
+
+upsThreePhaseOutputVoltageR OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Output VoltageR"
+ ::= { upsThreePhaseOutputGrp 2 }
+
+
+upsThreePhaseOutputVoltageS OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Output VoltageS"
+ ::= { upsThreePhaseOutputGrp 3 }
+
+
+upsThreePhaseOutputVoltageT OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Output VoltageT"
+ ::= { upsThreePhaseOutputGrp 4 }
+
+
+upsThreePhaseOutputLoadPercentageR OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Load PercentageR"
+ ::= { upsThreePhaseOutputGrp 5 }
+
+
+upsThreePhaseOutputLoadPercentageS OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Load PercentageS"
+ ::= { upsThreePhaseOutputGrp 6 }
+
+
+upsThreePhaseOutputLoadPercentageT OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Load PercentageT"
+ ::= { upsThreePhaseOutputGrp 7 }
+
+
+upsThreePhaseBypassSourceFrequency OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Bypass Frequency"
+ ::= { upsThreePhaseBypassGrp 1 }
+
+
+upsThreePhaseBypssSourceVoltageR OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Bypass VoltageR"
+ ::= { upsThreePhaseBypassGrp 2 }
+
+
+upsThreePhaseBypssSourceVoltageS OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Bypass VoltageS"
+ ::= { upsThreePhaseBypassGrp 3 }
+
+
+upsThreePhaseBypssSourceVoltageT OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Bypass VoltageT"
+ ::= { upsThreePhaseBypassGrp 4 }
+
+
+upsThreePhaseDCandRectifierStatusRecRotError OBJECT-TYPE
+ SYNTAX INTEGER {
+ yes(14),
+ no(16) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Rectifier Rotation Error"
+ ::= { upsThreePhaseDCandRectifierStatusGrp 1 }
+
+
+upsThreePhaseDCandRectifierStatusLowBatteryShutdown OBJECT-TYPE
+ SYNTAX INTEGER {
+ yes(14),
+ no(16) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Low Battery Shutdown"
+ ::= { upsThreePhaseDCandRectifierStatusGrp 2 }
+
+
+upsThreePhaseDCandRectifierStatusLowBattery OBJECT-TYPE
+ SYNTAX INTEGER {
+ yes(14),
+ no(16) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Low Battery"
+ ::= { upsThreePhaseDCandRectifierStatusGrp 3 }
+
+
+upsThreePhaseDCandRectifierStatusInAndOut OBJECT-TYPE
+ SYNTAX INTEGER {
+ threeInOneOut(2),
+ threeInThreeOut(3) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "In And Put"
+ ::= { upsThreePhaseDCandRectifierStatusGrp 4 }
+
+
+upsThreePhaseDCandRectifierStatusBatteryStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ backup(4),
+ acnormal(5) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Back Status"
+ ::= { upsThreePhaseDCandRectifierStatusGrp 5 }
+
+
+upsThreePhaseDCandRectifierStatusChargeStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ boost(6),
+ float(7),
+ no(16) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Charge Status"
+ ::= { upsThreePhaseDCandRectifierStatusGrp 6 }
+
+
+upsThreePhaseDCandRectifierStatusRecOperating OBJECT-TYPE
+ SYNTAX INTEGER {
+ yes(14),
+ no(16) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Rectifier Operating"
+ ::= { upsThreePhaseDCandRectifierStatusGrp 7 }
+
+
+upsThreePhaseUPSStatusBypassFreqFail OBJECT-TYPE
+ SYNTAX INTEGER {
+ yes(14),
+ no(16) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Bypass Status"
+ ::= { upsThreePhaseUPSStatusGrp 1 }
+
+
+upsThreePhaseUPSStatusManualBypassBreaker OBJECT-TYPE
+ SYNTAX INTEGER {
+ close(8),
+ open(9) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Breaker Status"
+ ::= { upsThreePhaseUPSStatusGrp 2 }
+
+
+upsThreePhaseUPSStatusACStatus OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(10),
+ abnormal(11) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "AC Status"
+ ::= { upsThreePhaseUPSStatusGrp 3 }
+
+
+upsThreePhaseUPSStaticSwitchMode OBJECT-TYPE
+ SYNTAX INTEGER {
+ invermode(12),
+ bypassmode(13) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Switch Mode"
+ ::= { upsThreePhaseUPSStatusGrp 4 }
+
+
+upsThreePhaseUPSStatusInverterOperating OBJECT-TYPE
+ SYNTAX INTEGER {
+ yes(14),
+ no(16) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Operating"
+ ::= { upsThreePhaseUPSStatusGrp 5 }
+
+
+upsThreePhaseFaultStatusEmergencyStop OBJECT-TYPE
+ SYNTAX INTEGER {
+ yes(14),
+ no(16) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Emergency Stop"
+ ::= { upsThreePhaseFaultStatusGrp 1 }
+
+
+upsThreePhaseFaultStatusHighDCShutdown OBJECT-TYPE
+ SYNTAX INTEGER {
+ yes(14),
+ no(16) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "High DC Shutdown"
+ ::= { upsThreePhaseFaultStatusGrp 2 }
+
+
+upsThreePhaseFaultStatusBypassBreaker OBJECT-TYPE
+ SYNTAX INTEGER {
+ yes(14),
+ no(16) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Bypass Breaker"
+ ::= { upsThreePhaseFaultStatusGrp 3 }
+
+
+upsThreePhaseFaultStatusOverLoad OBJECT-TYPE
+ SYNTAX INTEGER {
+ yes(14),
+ no(16) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Over Load"
+ ::= { upsThreePhaseFaultStatusGrp 4 }
+
+
+upsThreePhaseFaultStatusInverterOutputFail OBJECT-TYPE
+ SYNTAX INTEGER {
+ yes(14),
+ no(16) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Output Fail"
+ ::= { upsThreePhaseFaultStatusGrp 5 }
+
+
+upsThreePhaseFaultStatusOverTemperature OBJECT-TYPE
+ SYNTAX INTEGER {
+ yes(14),
+ no(16) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Over Temperature"
+ ::= { upsThreePhaseFaultStatusGrp 6 }
+
+
+upsThreePhaseFaultStatusShortCircuit OBJECT-TYPE
+ SYNTAX INTEGER {
+ yes(14),
+ no(16) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Short Circuit"
+ ::= { upsThreePhaseFaultStatusGrp 7 }
+
+
+upsThreePhaseRatingRectifierVoltage OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Rectifier Voltage"
+ ::= { upsThreePhaseRatingGrp 1 }
+
+
+upsThreePhaseRatingRectifierFrequency OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Rectifier Frequency"
+ ::= { upsThreePhaseRatingGrp 2 }
+
+
+upsThreePhaseRatingBypassVoltage OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Bypass Voltage"
+ ::= { upsThreePhaseRatingGrp 3 }
+
+
+upsThreePhaseRatingBypassFrequency OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Bypass Frequency"
+ ::= { upsThreePhaseRatingGrp 4 }
+
+
+upsThreePhaseRatingOutputVoltage OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Output Voltage"
+ ::= { upsThreePhaseRatingGrp 5 }
+
+
+upsThreePhaseRatingOutputFrequency OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Output Frequency"
+ ::= { upsThreePhaseRatingGrp 6 }
+
+
+upsThreePhaseRatingBatteryVoltage OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Battery Voltage"
+ ::= { upsThreePhaseRatingGrp 7 }
+
+
+upsThreePhaseRatingPower OBJECT-TYPE
+ SYNTAX DisplayString
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Power Rating"
+ ::= { upsThreePhaseRatingGrp 8 }
+
+
+-----------------------
+-----------------------
+
+upsEnvStatus OBJECT IDENTIFIER ::= { upsEnvironment 1 }
+
+upsEnvTemperature OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The ambient environment temperature."
+ ::= { upsEnvStatus 1 }
+
+
+upsEnvHumidity OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "The environment humidity."
+ ::= { upsEnvStatus 2 }
+
+
+upsEnvOverTemperature OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Alarm dupsAlarmOverTemperature on when the environment
+ temperature over the value."
+ ::= { upsEnvSetting 1 }
+
+
+upsEnvOverHumidity OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Alarm dupsAlarmOverHumidity on when the environment
+ humidity over the value."
+ ::= { upsEnvSetting 3 }
+
+
+upsEnvSecurity1 OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(1),
+ abnormal(2) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Security status"
+ ::= { upsEnvStatus 5 }
+
+
+upsEnvSecurity2 OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(1),
+ abnormal(2) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Security status"
+ ::= { upsEnvStatus 6 }
+
+
+upsEnvSecurity3 OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(1),
+ abnormal(2) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Security status"
+ ::= { upsEnvStatus 7 }
+
+
+upsEnvSecurity4 OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(1),
+ abnormal(2) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Security status"
+ ::= { upsEnvStatus 8 }
+
+
+upsEnvSecurity5 OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(1),
+ abnormal(2) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Security status"
+ ::= { upsEnvStatus 9 }
+
+
+upsEnvSecurity6 OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(1),
+ abnormal(2) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Security status"
+ ::= { upsEnvStatus 10 }
+
+
+upsEnvSecurity7 OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(1),
+ abnormal(2) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Security status"
+ ::= { upsEnvStatus 11 }
+
+
+upsEnvWater OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(1),
+ abnormal(2) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Water status"
+ ::= { upsEnvStatus 3 }
+
+
+upsEnvSmoke OBJECT-TYPE
+ SYNTAX INTEGER {
+ normal(1),
+ abnormal(2) }
+ ACCESS read-only
+ STATUS mandatory
+ DESCRIPTION
+ "Smoke status"
+ ::= { upsEnvStatus 4 }
+
+
+upsEnvSetting OBJECT IDENTIFIER ::= { upsEnvironment 2 }
+
+upsEnvUnderTemperature OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Alarm dupsAlarmUnderTemperature on when the environment
+ temperature below the value."
+ ::= { upsEnvSetting 2 }
+
+
+upsEnvUnderHumidity OBJECT-TYPE
+ SYNTAX INTEGER
+ ACCESS read-write
+ STATUS mandatory
+ DESCRIPTION
+ "Alarm dupsAlarmUnderHumidity on when the environment
+ humidity below the value."
+ ::= { upsEnvSetting 4 }
+
+
+
+communicationLost TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "SEVERE: Communication to the UPS has been lost. Steps
+ to reestablish communication are in progress."
+ --#TYPE "PPC UPS: Communication failure"
+ --#SUMMARY "Communication to the UPS has been lost."
+ --#ARGUMENTS { }
+ --#SEVERITY CRITICAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 1
+
+
+
+upsOverLoad TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "SEVERE: The UPS has sensed a load greater than 100 percent
+ of its rated capacity."
+ --#TYPE "PPC UPS: UPS overload"
+ --#SUMMARY "The UPS has sensed a load greater than 100 percent of its rated capacity."
+ --#ARGUMENTS { }
+ --#SEVERITY CRITICAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 2
+
+
+
+upsDiagnosticsFailed TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "SEVERE: The UPS failed its internal diagnostic self-test."
+ --#TYPE "PPC UPS: Failed self-test"
+ --#SUMMARY "The UPS has failed its internal diagnostic self-test."
+ --#ARGUMENTS { }
+ --#SEVERITY CRITICAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 3
+
+
+
+upsDischarged TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "SEVERE: The UPS just started a runtime calibration
+ discharge. The UPS batteries are being discharged."
+ --#TYPE "PPC UPS: Deep discharge"
+ --#SUMMARY "The UPS has just started a runtime calibration discharge."
+ --#ARGUMENTS { }
+ --#SEVERITY CRITICAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 4
+
+
+
+upsOnBattery TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: The UPS has switched to battery backup power."
+ --#TYPE "PPC UPS: On battery"
+ --#SUMMARY "The UPS has switched to battery backup power."
+ --#ARGUMENTS { }
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 5
+
+
+
+boostOn TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: The UPS has enabled Boost."
+ --#TYPE "PPC UPS: SmartBoost"
+ --#SUMMARY "The UPS has enabled Boost."
+ --#ARGUMENTS { }
+ --#SEVERITY MINOR
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 6
+
+
+
+lowBattery TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "SEVERE: The UPS batteries are low and will soon be exhausted.
+ If utility power is not restored the UPS will put itself
+ to 'sleep' and immediately cut power to the load."
+ --#TYPE "PPC UPS: Low battery"
+ --#SUMMARY "The UPS batteries are low and will soon be exhausted."
+ --#ARGUMENTS { }
+ --#SEVERITY CRITICAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE DEGRADED
+ ::= 7
+
+
+
+communicationEstablished TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "INFORMATION: Communication with the UPS has been
+ established."
+ --#TYPE "PPC UPS: Communication established"
+ --#SUMMARY "Communication with the UPS has been established."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 8
+
+
+
+powerRestored TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "INFORMATION: Utility power has been restored."
+ --#TYPE "PPC UPS: Utility restored"
+ --#SUMMARY "Normal power has been restored to the UPS."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 9
+
+
+
+upsDiagnosticsPassed TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "INFORMATION: The UPS passed its internal self-test."
+ --#TYPE "PPC UPS: Passed self-test"
+ --#SUMMARY "The UPS has passed its internal self-test."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 10
+
+
+
+returnFromLowBattery TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "INFORMATION: The UPS has returned from a low battery
+ condition."
+ --#TYPE "PPC UPS: Battery normal"
+ --#SUMMARY "The UPS has returned from a low battery condition."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 11
+
+
+
+upsTurnedOff TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: The UPS has been turned 'off' by the
+ management station."
+ --#TYPE "PPC UPS: Switching off"
+ --#SUMMARY "The UPS is being switched off by a management station."
+ --#ARGUMENTS { }
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 12
+
+
+
+upsSleeping TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: The UPS is entering 'sleep' mode. Power
+ to the load will be cut off."
+ --#TYPE "PPC UPS: Going to sleep"
+ --#SUMMARY "The UPS is going into sleep mode."
+ --#ARGUMENTS { }
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 13
+
+
+
+upsWokeUp TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "INFORMATION: The UPS woke up from 'sleep' mode. Power
+ to the load has been restored."
+ --#TYPE "PPC UPS: Wake up"
+ --#SUMMARY "The UPS has woke up from sleep mode."
+ --#ARGUMENTS { }
+ --#SEVERITY INFORMATIONAL
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE OPERATIONAL
+ ::= 14
+
+
+
+upsRebootStarted TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: The UPS has started its reboot sequence. After
+ the specified delay the UPS will perform a reboot."
+ --#TYPE "PPC UPS: Starting reboot"
+ --#SUMMARY "The UPS has started its reboot sequence."
+ --#ARGUMENTS { }
+ --#SEVERITY MAJOR
+ --#TIMEINDEX 1
+ --#HELP ""
+ --#HELPTAG 0
+ --#STATE NONOPERATIONAL
+ ::= 15
+
+
+envOverTemperature TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: The environment temperature exceed the normal value."
+ ::= 16
+
+
+envTemperatureNormal TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "INFORMATION: The environment temperature is normal."
+ ::= 17
+
+
+envOverHumidity TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: The environment humidity exceed the normal value."
+ ::= 18
+
+
+envHumidityNormal TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "INFORMATION: The environment humidity is normal."
+ ::= 19
+
+
+envSmokeAbnormal TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: Smoke is abnormal."
+ ::= 20
+
+
+envWaterAbnormal TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: Water is abnormal."
+ ::= 21
+
+
+envSecurityAbnormal TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: Security is abnormal."
+ ::= 22
+
+
+--envSmokeNormal TRAP-TYPE
+-- ENTERPRISE ppc
+-- DESCRIPTION
+-- "INFORMATION: Smoke is normal."
+-- ::= 23
+
+
+envWaterNormal TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "INFORMATION: Water is normal."
+ ::= 24
+
+
+--envSecurityNormal TRAP-TYPE
+-- ENTERPRISE ppc
+-- DESCRIPTION
+-- "INFORMATION: Security is normal."
+-- ::= 25
+
+
+envGasAbnormal TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: Gas Alarm"
+ ::= 26
+
+
+upsTemp TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: UPS Temperature Overrun"
+ ::= 27
+
+
+upsLoadNormal TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: UPS Load Normal"
+ ::= 28
+
+
+upsTempNormal TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: UPS temperature Normal"
+ ::= 29
+
+
+envUnderTemperature TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: The environment temperature below the normal value."
+ ::= 30
+
+
+envUnderHumidity TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: The environment humidity below the normal value."
+ ::= 31
+
+
+upsBypass TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: The UPS is entering 'bypass' mode."
+ ::= 32
+
+
+envSecurity1 TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: Security1 Alarm."
+ ::= 33
+
+
+envSecurity2 TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: Security2 Alarm."
+ ::= 34
+
+
+envSecurity3 TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: Security3 Alarm."
+ ::= 35
+
+
+envSecurity4 TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: Security4 Alarm."
+ ::= 36
+
+
+envSecurity5 TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: Security5 Alarm."
+ ::= 37
+
+
+envSecurity6 TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: Security6 Alarm."
+ ::= 38
+
+
+envSecurity7 TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: Security7 Alarm."
+ ::= 39
+
+
+--envSecurity1Return TRAP-TYPE
+-- ENTERPRISE ppc
+-- DESCRIPTION
+-- "WARNING: Security1 Normal."
+-- ::= 40
+
+
+--envSecurity2Return TRAP-TYPE
+-- ENTERPRISE ppc
+-- DESCRIPTION
+-- "WARNING: Security2 Normal"
+-- ::= 41
+
+
+--envSecurity3Return TRAP-TYPE
+-- ENTERPRISE ppc
+-- DESCRIPTION
+-- "WARNING: Security3 Normal."
+-- ::= 42
+
+
+--envSecurity4Return TRAP-TYPE
+-- ENTERPRISE ppc
+-- DESCRIPTION
+-- "WARNING: Security4 Normal."
+-- ::= 43
+
+
+--envSecurity5Return TRAP-TYPE
+-- ENTERPRISE ppc
+-- DESCRIPTION
+-- "WARNING: Security5 Normal."
+-- ::= 44
+
+
+--envSecurity6Return TRAP-TYPE
+-- ENTERPRISE ppc
+-- DESCRIPTION
+-- "WARNING: Security6 Normal."
+-- ::= 45
+
+
+--envSecurity7Return TRAP-TYPE
+-- ENTERPRISE ppc
+-- DESCRIPTION
+-- "WARNING: Security7 Normal."
+-- ::= 46
+
+
+upsRecroterror TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: Rectifier Rotation Error"
+ ::= 47
+
+
+upsBypassFreFail TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: Bypass Frequency Fail"
+ ::= 48
+
+
+upsBypassacnormal TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: Bypass AC Normal"
+ ::= 49
+
+
+upsBypassacabnormal TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: Bypass AC Abnormal"
+ ::= 50
+
+
+upsTest TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: UPS Test"
+ ::= 51
+
+
+upsScheduleShutdown TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: UPS Schedule Shutdown"
+ ::= 52
+
+upsBypassReturn TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "The UPS return from Bypass Mode"
+ ::= 53
+
+upsShortCircuitShutdown TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "The UPS Short Circuit Shutdown"
+ ::= 54
+
+upsInverterOutputFailShutdown TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "The UPS Inverter Output Fail Shutdown"
+ ::= 55
+
+upsBypassBreadkerOnShutdown TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "The UPS Manual Bypass Breaker on Shutdown"
+ ::= 56
+
+upsHighDCShutdown TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "The UPS High DC Shutdown"
+ ::= 57
+
+upsEmergencyStop TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "The UPS Emergency Stop"
+ ::= 58
+
+upsInverterMode TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "The UPS Static Switch in Inverter Mode"
+ ::= 59
+
+upsBypassMode TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "The UPS Static Switch in Bypass Mode"
+ ::= 60
+
+upsOverTemperatureShutdown TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "The UPS Over Temperature Shutdown"
+ ::= 61
+
+upsOverLoadShutdown TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "The UPS Overload Shutdown"
+ ::= 62
+
+upsCapacityUnderrun TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "The UPS Capacity Underrun"
+ ::= 63
+
+upsCapacityNormal TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "The UPS Capacity Normal"
+ ::= 64
+
+upsLowBatteryShutdown TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "The UPS Low Battery Shutdown"
+ ::= 67
+
+buckOn TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: The UPS has enabled Buck."
+ ::= 68
+
+returnFromBuck TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: The UPS has return from Buck."
+ ::= 69
+
+returnFromBoost TRAP-TYPE
+ ENTERPRISE ppc
+ DESCRIPTION
+ "WARNING: The UPS has return from Boost."
+ ::= 70
+
+END
diff --git a/tests/snmpsim/logmaster.snmprec b/tests/snmpsim/logmaster.snmprec
new file mode 100644
index 0000000000..b575ff86c0
--- /dev/null
+++ b/tests/snmpsim/logmaster.snmprec
@@ -0,0 +1,2 @@
+1.3.6.1.2.1.1.1.0|4|LogWeb
+1.3.6.1.2.1.1.2.0|6|.1.3.6.1.4.1.935