mirror of
https://github.com/librenms/librenms.git
synced 2024-09-21 18:38:25 +00:00
move RADLAN mibs to mib root
git-svn-id: http://www.observium.org/svn/observer/trunk@1570 61d68cd4-352d-0410-923a-c4978735b2b8
This commit is contained in:
parent
6b9d05653c
commit
4a48d283b3
File diff suppressed because it is too large
Load Diff
@ -1,439 +0,0 @@
|
||||
ENTITY-SENSOR-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
-- draft-ietf-entmib-sensor-mib-02.txt
|
||||
|
||||
IMPORTS
|
||||
rlEnv FROM RADLAN-MIB
|
||||
MODULE-IDENTITY, OBJECT-TYPE,
|
||||
Integer32, Unsigned32, mib-2
|
||||
FROM SNMPv2-SMI
|
||||
MODULE-COMPLIANCE, OBJECT-GROUP
|
||||
FROM SNMPv2-CONF
|
||||
TEXTUAL-CONVENTION, TimeStamp
|
||||
FROM SNMPv2-TC
|
||||
entPhysicalIndex, entityPhysicalGroup
|
||||
FROM ENTITY-MIB
|
||||
SnmpAdminString
|
||||
FROM SNMP-FRAMEWORK-MIB;
|
||||
|
||||
entitySensorMIB MODULE-IDENTITY
|
||||
LAST-UPDATED "200210160000Z"
|
||||
ORGANIZATION "IETF Entity MIB Working Group"
|
||||
CONTACT-INFO
|
||||
" Andy Bierman
|
||||
Cisco Systems, Inc.
|
||||
Tel: +1 408-527-3711
|
||||
E-mail: abierman@cisco.com
|
||||
Postal: 170 West Tasman Drive
|
||||
San Jose, CA USA 95134
|
||||
|
||||
Dan Romascanu
|
||||
Avaya Communication
|
||||
Tel: +972-3-645-8414
|
||||
Email: dromasca@avaya.com
|
||||
Postal: Atidim technology Park, Bldg. #3
|
||||
Tel Aviv, Israel, 61131
|
||||
|
||||
K.C. Norseth
|
||||
L-3 Communications
|
||||
Tel: +1 801-594-2809
|
||||
Email: kenyon.c.norseth@L-3com.com
|
||||
Postal: 640 N. 2200 West.
|
||||
Salt Lake City, Utah 84116-0850
|
||||
|
||||
Send comments to <entmib@ietf.org>
|
||||
Mailing list subscription info:
|
||||
http://www.ietf.org/mailman/listinfo/entmib "
|
||||
DESCRIPTION
|
||||
"This module defines Entity MIB extensions for physical
|
||||
sensors."
|
||||
REVISION "200210160000Z"
|
||||
DESCRIPTION
|
||||
"Initial version of the Entity Sensor MIB module, published
|
||||
as RFC xxxx." -- RFC Editor assigns xxxx
|
||||
-- ::= { mib-2 xxx } ## IANA needs to assign xxx
|
||||
::= { rlEnv 2 }
|
||||
|
||||
entitySensorObjects OBJECT IDENTIFIER
|
||||
::= { entitySensorMIB 1 }
|
||||
-- entitySensorNotifications OBJECT IDENTIFIER
|
||||
-- ::= { entitySensorMIB 2 }
|
||||
entitySensorConformance OBJECT IDENTIFIER
|
||||
::= { entitySensorMIB 3 }
|
||||
|
||||
--
|
||||
-- Textual Conventions
|
||||
--
|
||||
|
||||
EntitySensorDataType ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An object using this data type represents the Entity Sensor
|
||||
measurement data type associated with a physical sensor
|
||||
value. The actual data units are determined by examining an
|
||||
object of this type together with the associated
|
||||
EntitySensorDataScale object.
|
||||
|
||||
An object of this type SHOULD be defined together with
|
||||
objects of type EntitySensorDataScale and
|
||||
EntitySensorPrecision. Together, associated objects of
|
||||
these three types are used to identify the semantics of an
|
||||
object of type EntitySensorValue.
|
||||
|
||||
Valid values are:
|
||||
|
||||
other(1): a measure other than those listed below
|
||||
unknown(2): unknown measurement, or arbitrary,
|
||||
relative numbers
|
||||
voltsAC(3): electric potential
|
||||
voltsDC(4): electric potential
|
||||
amperes(5): electric current
|
||||
watts(6): power
|
||||
hertz(7): frequency
|
||||
celsius(8): temperature
|
||||
percentRH(9): percent relative humidity
|
||||
rpm(10): shaft revolutions per minute
|
||||
cmm(11),: cubic meters per minute (airflow)
|
||||
truthvalue(12): value takes { true(1), false(2) }
|
||||
|
||||
"
|
||||
SYNTAX INTEGER {
|
||||
other(1),
|
||||
unknown(2),
|
||||
voltsAC(3),
|
||||
voltsDC(4),
|
||||
amperes(5),
|
||||
watts(6),
|
||||
hertz(7),
|
||||
celsius(8),
|
||||
percentRH(9),
|
||||
rpm(10),
|
||||
cmm(11),
|
||||
truthvalue(12)
|
||||
}
|
||||
|
||||
EntitySensorDataScale ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An object using this data type represents a data scaling
|
||||
factor, represented with an International System of Units
|
||||
(SI) prefix. The actual data units are determined by
|
||||
examining an object of this type together with the
|
||||
associated EntitySensorDataType object.
|
||||
|
||||
An object of this type SHOULD be defined together with
|
||||
objects of type EntitySensorDataType and
|
||||
EntitySensorPrecision. Together, associated objects of
|
||||
these three types are used to identify the semantics of an
|
||||
object of type EntitySensorValue."
|
||||
REFERENCE
|
||||
"TBD"
|
||||
SYNTAX INTEGER {
|
||||
yocto(1), -- 10^-24
|
||||
zepto(2), -- 10^-21
|
||||
atto(3), -- 10^-18
|
||||
femto(4), -- 10^-15
|
||||
pico(5), -- 10^-12
|
||||
nano(6), -- 10^-9
|
||||
micro(7), -- 10^-6
|
||||
milli(8), -- 10^-3
|
||||
units(9), -- 10^0
|
||||
kilo(10), -- 10^3
|
||||
mega(11), -- 10^6
|
||||
giga(12), -- 10^9
|
||||
tera(13), -- 10^12
|
||||
exa(14), -- 10^15
|
||||
peta(15), -- 10^18
|
||||
zetta(16), -- 10^21
|
||||
yotta(17) -- 10^24
|
||||
}
|
||||
|
||||
EntitySensorPrecision ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An object using this data type represents a sensor
|
||||
precision range.
|
||||
|
||||
An object of this type SHOULD be defined together with
|
||||
objects of type EntitySensorDataType and
|
||||
EntitySensorDataScale. Together, associated objects of
|
||||
these three types are used to identify the semantics of an
|
||||
object of type EntitySensorValue.
|
||||
|
||||
If an object of this type contains a value in the range 1 to
|
||||
9, it represents the number of decimal places in the
|
||||
fractional part of an associated EntitySensorValue fixed-
|
||||
point number.
|
||||
|
||||
If an object of this type contains a value in the range -8
|
||||
to -1, it represents the number of accurate digits in the
|
||||
associated EntitySensorValue fixed-point number.
|
||||
|
||||
The value zero indicates the associated EntitySensorValue
|
||||
object is not a fixed-point number.
|
||||
|
||||
Agent implementors must choose a value for the associated
|
||||
EntitySensorPrecision object so that the precision and
|
||||
accuracy of the associated EntitySensorValue object is
|
||||
correctly indicated.
|
||||
|
||||
For example, a physical entity representing a temperature
|
||||
sensor that can measure 0 degrees to 100 degrees C in 0.1
|
||||
degree increments, +/- 0.05 degrees, would have an
|
||||
EntitySensorPrecision value of '1', an EntitySensorDataScale
|
||||
value of 'units(9)', and an EntitySensorValue ranging from
|
||||
'0' to '1000'. The EntitySensorValue would be interpreted
|
||||
as 'degrees C * 10'."
|
||||
SYNTAX Integer32 (-8..9)
|
||||
|
||||
EntitySensorValue ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An object using this data type represents an Entity Sensor
|
||||
value.
|
||||
An object of this type SHOULD be defined together with
|
||||
objects of type EntitySensorDataType, EntitySensorDataScale
|
||||
and EntitySensorPrecision. Together, associated objects of
|
||||
those three types are used to identify the semantics of an
|
||||
object of this data type.
|
||||
|
||||
The semantics of an object using this data type are
|
||||
determined by the value of the associated
|
||||
EntitySensorDataType object.
|
||||
|
||||
If the associated EntitySensorDataType object is equal to
|
||||
'voltsAC(3)', 'voltsDC(4)', 'amperes(5)', 'watts(6),
|
||||
'hertz(7)', 'celsius(8)', or 'cmm(11)', then an object of
|
||||
this type MUST contain a fixed point number ranging from
|
||||
-999,999,999 to +999,999,999. The value -1000000000
|
||||
indicates an underflow error. The value +1000000000
|
||||
indicates an overflow error. The EntitySensorPrecision
|
||||
indicates how many fractional digits are represented in the
|
||||
associated EntitySensorValue object.
|
||||
|
||||
If the associated EntitySensorDataType object is equal to
|
||||
'percentRH(9)', then an object of this type MUST contain a
|
||||
number ranging from 0 to 100.
|
||||
|
||||
If the associated EntitySensorDataType object is equal to
|
||||
'rpm(10)', then an object of this type MUST contain a number
|
||||
ranging from -999,999,999 to +999,999,999.
|
||||
|
||||
If the associated EntitySensorDataType object is equal to
|
||||
'truthvalue(12)', then an object of this type MUST contain
|
||||
either the value 'true(1)' or the value 'false(2)'.
|
||||
|
||||
If the associated EntitySensorDataType object is equal to
|
||||
'other(1)' or unknown(2)', then an object of this type MUST
|
||||
contain a number ranging from -1000000000 to 1000000000."
|
||||
SYNTAX Integer32 (-1000000000..1000000000)
|
||||
|
||||
EntitySensorStatus ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An object using this data type represents the operational
|
||||
status of a physical sensor.
|
||||
|
||||
The value 'ok(1)' indicates that the agent can obtain the
|
||||
sensor value.
|
||||
|
||||
The value 'unavailable(2)' indicates that the agent
|
||||
presently cannot obtain the sensor value.
|
||||
|
||||
The value 'nonoperational(3)' indicates that the agent
|
||||
believes the sensor is broken. The sensor could have a hard
|
||||
failure (disconnected wire), or a soft failure such as out-
|
||||
of-range, jittery, or wildly fluctuating readings."
|
||||
SYNTAX INTEGER {
|
||||
ok(1),
|
||||
unavailable(2),
|
||||
nonoperational(3)
|
||||
}
|
||||
|
||||
--
|
||||
-- Entity Sensor Table
|
||||
--
|
||||
|
||||
entPhySensorTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF EntPhySensorEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This table contains one row per physical sensor represented
|
||||
by an associated row in the entPhysicalTable."
|
||||
::= { entitySensorObjects 1 }
|
||||
|
||||
entPhySensorEntry OBJECT-TYPE
|
||||
SYNTAX EntPhySensorEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Information about a particular physical sensor.
|
||||
|
||||
An entry in this table describes the present reading of a
|
||||
sensor, the measurement units and scale, and sensor
|
||||
operational status.
|
||||
|
||||
Entries are created in this table by the agent. An entry
|
||||
for each physical sensor SHOULD be created at the same time
|
||||
as the associated entPhysicalEntry. An entry SHOULD be
|
||||
destroyed if the associated entPhysicalEntry is destroyed."
|
||||
INDEX { entPhysicalIndex } -- SPARSE-AUGMENTS
|
||||
::= { entPhySensorTable 1 }
|
||||
|
||||
EntPhySensorEntry ::= SEQUENCE {
|
||||
entPhySensorType EntitySensorDataType,
|
||||
entPhySensorScale EntitySensorDataScale,
|
||||
entPhySensorPrecision EntitySensorPrecision,
|
||||
entPhySensorValue EntitySensorValue,
|
||||
entPhySensorOperStatus EntitySensorStatus,
|
||||
entPhySensorUnitsDisplay SnmpAdminString,
|
||||
entPhySensorValueTimeStamp TimeStamp,
|
||||
entPhySensorValueUpdateRate Unsigned32
|
||||
}
|
||||
|
||||
entPhySensorType OBJECT-TYPE
|
||||
SYNTAX EntitySensorDataType
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The type of data returned by the associated
|
||||
entPhySensorValue object.
|
||||
|
||||
This object SHOULD be set by the agent during entry
|
||||
creation, and the value SHOULD NOT change during operation."
|
||||
::= { entPhySensorEntry 1 }
|
||||
|
||||
entPhySensorScale OBJECT-TYPE
|
||||
SYNTAX EntitySensorDataScale
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The exponent to apply to values returned by the associated
|
||||
entPhySensorValue object.
|
||||
|
||||
This object SHOULD be set by the agent during entry
|
||||
creation, and the value SHOULD NOT change during operation."
|
||||
::= { entPhySensorEntry 2 }
|
||||
|
||||
entPhySensorPrecision OBJECT-TYPE
|
||||
SYNTAX EntitySensorPrecision
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The number of decimal places of precision in fixed-point
|
||||
sensor values returned by the associated entPhySensorValue
|
||||
object.
|
||||
|
||||
This object SHOULD be set to '0' when the associated
|
||||
entPhySensorType value is not a fixed-point type: e.g.,
|
||||
'percentRH(9)', 'rpm(10)', 'cmm(11)', or 'truthvalue(12)'.
|
||||
|
||||
This object SHOULD be set by the agent during entry
|
||||
creation, and the value SHOULD NOT change during operation."
|
||||
::= { entPhySensorEntry 3 }
|
||||
|
||||
entPhySensorValue OBJECT-TYPE
|
||||
SYNTAX EntitySensorValue
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The most recent measurement obtained by the agent for this
|
||||
sensor.
|
||||
|
||||
To correctly interpret the value of this object, the
|
||||
associated entPhySensorType, entPhySensorScale, and
|
||||
entPhySensorPrecision objects must also be examined."
|
||||
::= { entPhySensorEntry 4 }
|
||||
|
||||
entPhySensorOperStatus OBJECT-TYPE
|
||||
SYNTAX EntitySensorStatus
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The operational status of the sensor."
|
||||
::= { entPhySensorEntry 5 }
|
||||
|
||||
entPhySensorUnitsDisplay OBJECT-TYPE
|
||||
SYNTAX SnmpAdminString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A textual description of the data units that should be used
|
||||
in the display of entPhySensorValue."
|
||||
::= { entPhySensorEntry 6 }
|
||||
|
||||
entPhySensorValueTimeStamp OBJECT-TYPE
|
||||
SYNTAX TimeStamp
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The value of sysUpTime at the time the status and/or value
|
||||
of this sensor was last obtained by the agent."
|
||||
::= { entPhySensorEntry 7 }
|
||||
|
||||
entPhySensorValueUpdateRate OBJECT-TYPE
|
||||
SYNTAX Unsigned32
|
||||
UNITS "milliseconds"
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An indication of the frequency that the agent updates the
|
||||
associated entPhySensorValue object, representing in
|
||||
milliseconds.
|
||||
|
||||
The value zero indicates:
|
||||
|
||||
- the sensor value is updated on demand (e.g.,
|
||||
when polled by the agent for a get-request),
|
||||
- the sensor value is updated when the sensor
|
||||
value changes (event-driven),
|
||||
- the agent does not know the update rate.
|
||||
|
||||
"
|
||||
::= { entPhySensorEntry 8 }
|
||||
|
||||
--
|
||||
-- Conformance Section
|
||||
--
|
||||
|
||||
entitySensorCompliances OBJECT IDENTIFIER
|
||||
::= { entitySensorConformance 1 }
|
||||
entitySensorGroups OBJECT IDENTIFIER
|
||||
::= { entitySensorConformance 2 }
|
||||
|
||||
entitySensorCompliance MODULE-COMPLIANCE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Describes the requirements for conformance to the Entity
|
||||
Sensor MIB module."
|
||||
MODULE -- this module
|
||||
MANDATORY-GROUPS { entitySensorValueGroup }
|
||||
|
||||
MODULE ENTITY-MIB
|
||||
MANDATORY-GROUPS { entityPhysicalGroup }
|
||||
|
||||
::= { entitySensorCompliances 1 }
|
||||
|
||||
-- Object Groups
|
||||
|
||||
entitySensorValueGroup OBJECT-GROUP
|
||||
OBJECTS {
|
||||
entPhySensorType,
|
||||
entPhySensorScale,
|
||||
entPhySensorPrecision,
|
||||
entPhySensorValue,
|
||||
entPhySensorOperStatus,
|
||||
entPhySensorUnitsDisplay,
|
||||
entPhySensorValueTimeStamp,
|
||||
entPhySensorValueUpdateRate
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A collection of objects representing physical entity sensor
|
||||
information."
|
||||
::= { entitySensorGroups 1 }
|
||||
|
||||
END
|
||||
|
||||
|