mirror of
https://github.com/librenms/librenms.git
synced 2024-09-21 10:28:13 +00:00
Put all Eaton mibs in the same subdir, update mibs, update YAML-files (#12197)
* put all Eaton mibs in the same subdir (common dependencies on EATON-OIDS, avoid file duplicates) * update all mibs (for which a more recent version was found) * update relevant YAML-files, so mib_dir points at eaton/.
This commit is contained in:
parent
b5d94c38a6
commit
45788130a0
@ -4,7 +4,7 @@ group: ups
|
||||
type: power
|
||||
icon: apc
|
||||
rfc1628_compat: true
|
||||
mib_dir: mge
|
||||
mib_dir: eaton
|
||||
over:
|
||||
- { graph: device_current, text: Current }
|
||||
- { graph: device_voltage, text: Voltage }
|
||||
|
@ -4,7 +4,7 @@ group: ups
|
||||
type: power
|
||||
icon: eaton
|
||||
rfc1628_compat: true
|
||||
mib_dir: mge
|
||||
mib_dir: eaton
|
||||
over:
|
||||
- { graph: device_current, text: Current }
|
||||
- { graph: device_voltage, text: Voltage }
|
||||
|
@ -6,7 +6,7 @@ over:
|
||||
- { graph: device_voltage, text: Voltage }
|
||||
- { graph: device_current, text: Current }
|
||||
- { graph: device_frequency, text: Frequencies }
|
||||
mib_dir: ups
|
||||
mib_dir: eaton
|
||||
discovery:
|
||||
-
|
||||
sysObjectID: .1.3.6.1.4.1.534.1
|
||||
|
@ -2,7 +2,7 @@ os: mgepdu
|
||||
text: 'Eaton MGE PDU'
|
||||
type: power
|
||||
icon: eaton
|
||||
mib_dir: mge
|
||||
mib_dir: eaton
|
||||
over:
|
||||
- { graph: device_current, text: Current }
|
||||
discovery:
|
||||
|
@ -3,7 +3,7 @@ EATON-EPDU-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
OBJECT-TYPE, NOTIFICATION-TYPE, MODULE-IDENTITY,
|
||||
Counter32, Unsigned32, Integer32
|
||||
Counter32, Unsigned32, Integer32, enterprises
|
||||
FROM SNMPv2-SMI
|
||||
NOTIFICATION-GROUP, OBJECT-GROUP, MODULE-COMPLIANCE
|
||||
FROM SNMPv2-CONF
|
||||
@ -12,8 +12,15 @@ IMPORTS
|
||||
pduAgent
|
||||
FROM EATON-OIDS;
|
||||
|
||||
-- The 3 assignments below are redundant with the one declared in the import file EATON-OIDS.txt
|
||||
-- because of the compatibility with some SNMP host software that do not support manufacturer import files.
|
||||
-- Take care not to diverge from the import file.
|
||||
eaton OBJECT IDENTIFIER ::= { enterprises 534 }
|
||||
products OBJECT IDENTIFIER ::= { eaton 6 }
|
||||
pduAgent OBJECT IDENTIFIER ::= { products 6 }
|
||||
|
||||
eatonEpdu MODULE-IDENTITY
|
||||
LAST-UPDATED "201312181200Z"
|
||||
LAST-UPDATED "201805301500Z"
|
||||
ORGANIZATION
|
||||
"Eaton Corporation"
|
||||
CONTACT-INFO
|
||||
@ -21,6 +28,27 @@ eatonEpdu MODULE-IDENTITY
|
||||
DESCRIPTION
|
||||
"The MIB module for Eaton ePDUs (Enclosure Power Distribution Units)."
|
||||
|
||||
REVISION "201805301500Z"
|
||||
DESCRIPTION
|
||||
"- Add information about architecture of the ePDU.
|
||||
- Add outlet automatic shutoff."
|
||||
|
||||
REVISION "201709111200Z"
|
||||
DESCRIPTION
|
||||
"- Add physical name for input, outlet and gang.
|
||||
- Add friendly name for input.
|
||||
- Add input identification for outlet.
|
||||
- Add the nominal power for ePDU input.
|
||||
- Add a new outlet type sdg300 (31)."
|
||||
|
||||
REVISION "201704201200Z"
|
||||
DESCRIPTION
|
||||
"Add color codes for each input and group. Color codes are decimal values."
|
||||
|
||||
REVISION "201502231200Z"
|
||||
DESCRIPTION
|
||||
"Fix compatibility with some SNMP host software by adding some assignments."
|
||||
|
||||
REVISION "201409291200Z"
|
||||
DESCRIPTION
|
||||
"Added outletControlSwitchable and outletControlShutoffDelay object."
|
||||
@ -74,7 +102,6 @@ eatonEpdu MODULE-IDENTITY
|
||||
"Initial release."
|
||||
::= { pduAgent 7 }
|
||||
|
||||
|
||||
UnixTimeStamp ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
@ -339,6 +366,8 @@ UnitEntry ::= SEQUENCE {
|
||||
INTEGER,
|
||||
unitType
|
||||
INTEGER,
|
||||
systemType
|
||||
INTEGER,
|
||||
inputCount
|
||||
Integer32,
|
||||
groupCount
|
||||
@ -452,7 +481,9 @@ unitType OBJECT-TYPE
|
||||
switched (1),
|
||||
advancedMonitored (2),
|
||||
managed (3),
|
||||
monitored (4)
|
||||
monitored (4),
|
||||
basic (5),
|
||||
inlineMonitored (6)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
@ -461,9 +492,22 @@ unitType OBJECT-TYPE
|
||||
Monitored (MI) - input and usually section/group monitoring.
|
||||
Advanced Monitored (AM) - input, section/group, and outlet monitoring.
|
||||
Switched (SW) - input and section/group monitoring, outlet switching.
|
||||
Managed (MA) - input, section/group, and outlet monitoring plug outlet switching."
|
||||
Basic (BA) - no communication card.
|
||||
Inline Monitored (IL) - input and usually one section/group monitoring."
|
||||
::= { unitEntry 10 }
|
||||
|
||||
systemType OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
unknown (0),
|
||||
g3ePDU (1),
|
||||
g3HDePDU (2)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Architecture of the ePDU electronic."
|
||||
::= { unitEntry 11 }
|
||||
|
||||
inputCount OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
@ -661,7 +705,11 @@ InputEntry ::= SEQUENCE {
|
||||
inputPowerCount
|
||||
Integer32,
|
||||
inputPlugType
|
||||
INTEGER
|
||||
INTEGER,
|
||||
inputFeedColor
|
||||
Unsigned32,
|
||||
inputFeedName
|
||||
OCTET STRING
|
||||
}
|
||||
|
||||
inputIndex OBJECT-TYPE
|
||||
@ -778,6 +826,25 @@ inputPlugType OBJECT-TYPE
|
||||
"Identifies which plug is on the input."
|
||||
::= { inputEntry 8 }
|
||||
|
||||
inputFeedColor OBJECT-TYPE
|
||||
SYNTAX Unsigned32 (0..16777215)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Color code of the input feed."
|
||||
::= { inputEntry 9 }
|
||||
|
||||
inputFeedName OBJECT-TYPE
|
||||
SYNTAX OCTET STRING (SIZE(1..31))
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A descriptive name for the input."
|
||||
::= { inputEntry 10 }
|
||||
|
||||
|
||||
|
||||
|
||||
inputVoltageTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF InputVoltageEntry
|
||||
MAX-ACCESS not-accessible
|
||||
@ -902,6 +969,8 @@ inputVoltageThUpperCritical OBJECT-TYPE
|
||||
that this object is not available."
|
||||
::= { inputVoltageEntry 8 }
|
||||
|
||||
|
||||
|
||||
inputCurrentTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF InputCurrentEntry
|
||||
MAX-ACCESS not-accessible
|
||||
@ -944,7 +1013,9 @@ InputCurrentEntry ::= SEQUENCE {
|
||||
inputCurrentCrestFactor
|
||||
Integer32,
|
||||
inputCurrentPercentLoad
|
||||
Integer32
|
||||
Integer32,
|
||||
inputPhaseDesignator
|
||||
DisplayString
|
||||
}
|
||||
|
||||
inputCurrentIndex OBJECT-TYPE
|
||||
@ -1058,6 +1129,17 @@ inputCurrentPercentLoad OBJECT-TYPE
|
||||
value indicates that this object is not available."
|
||||
::= { inputCurrentEntry 11 }
|
||||
|
||||
inputPhaseDesignator OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE(2..4))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Alphanumeric physical name for the input."
|
||||
::= { inputCurrentEntry 12 }
|
||||
|
||||
|
||||
|
||||
|
||||
inputPowerTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF InputPowerEntry
|
||||
MAX-ACCESS not-accessible
|
||||
@ -1209,6 +1291,8 @@ InputTotalPowerEntry ::= SEQUENCE {
|
||||
inputTotalPowerFactor
|
||||
Integer32,
|
||||
inputTotalVAR
|
||||
Integer32,
|
||||
inputPowerCapacity
|
||||
Integer32
|
||||
}
|
||||
|
||||
@ -1267,6 +1351,14 @@ inputTotalVAR OBJECT-TYPE
|
||||
that this object is not available."
|
||||
::= { inputTotalPowerEntry 8 }
|
||||
|
||||
inputPowerCapacity OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Typical power capacity of the input. A negative value indicates that
|
||||
the hardware current capacity is unknown."
|
||||
::= { inputTotalPowerEntry 9 }
|
||||
|
||||
|
||||
|
||||
@ -1301,6 +1393,12 @@ GroupEntry ::= SEQUENCE {
|
||||
groupBreakerStatus
|
||||
INTEGER,
|
||||
groupChildCount
|
||||
Integer32,
|
||||
groupColor
|
||||
Unsigned32,
|
||||
groupDesignator
|
||||
DisplayString,
|
||||
groupInputIndex
|
||||
Integer32
|
||||
}
|
||||
|
||||
@ -1365,6 +1463,33 @@ groupChildCount OBJECT-TYPE
|
||||
"Number of children for this group."
|
||||
::= { groupEntry 6 }
|
||||
|
||||
groupColor OBJECT-TYPE
|
||||
SYNTAX Unsigned32 (0..16777215)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Background color code of the group. Color codes are decimal values."
|
||||
::= { groupEntry 7 }
|
||||
|
||||
groupDesignator OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE(2..4))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Alphanumeric physical name for the group. This value may be written
|
||||
on the face of the unit."
|
||||
::= { groupEntry 8 }
|
||||
|
||||
groupInputIndex OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Identifies the input on which the group is connected."
|
||||
::= { groupEntry 9 }
|
||||
|
||||
|
||||
|
||||
groupChildTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF GroupChildEntry
|
||||
MAX-ACCESS not-accessible
|
||||
@ -1773,7 +1898,7 @@ GroupControlEntry ::= SEQUENCE {
|
||||
INTEGER,
|
||||
groupControlOffCmd
|
||||
Integer32,
|
||||
groupControl0nCmd
|
||||
groupControlOnCmd
|
||||
Integer32,
|
||||
groupControlRebootCmd
|
||||
Integer32
|
||||
@ -1810,7 +1935,7 @@ groupControlOffCmd OBJECT-TYPE
|
||||
commands. These will respond with an error if a command value of > 0 is written to this object."
|
||||
::= { groupControlEntry 3 }
|
||||
|
||||
groupControl0nCmd OBJECT-TYPE
|
||||
groupControlOnCmd OBJECT-TYPE
|
||||
SYNTAX Integer32 (-1..99999)
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
@ -1875,6 +2000,10 @@ OutletEntry ::= SEQUENCE {
|
||||
outletParentCount
|
||||
Integer32,
|
||||
outletType
|
||||
INTEGER,
|
||||
outletDesignator
|
||||
DisplayString,
|
||||
outletPhaseID
|
||||
INTEGER
|
||||
}
|
||||
|
||||
@ -1927,8 +2056,9 @@ outletType OBJECT-TYPE
|
||||
nema620 (26),
|
||||
nemaL620 (27),
|
||||
nemaL630 (28),
|
||||
nemaL715 (29),
|
||||
rf203p277 (30)
|
||||
nemaL715 (29),
|
||||
rf203p277 (30),
|
||||
sdg300 (31)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
@ -1936,6 +2066,41 @@ outletType OBJECT-TYPE
|
||||
"The physical type of outlet."
|
||||
::= { outletEntry 5 }
|
||||
|
||||
outletDesignator OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE(2..4))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Alphanumeric physical name for the outlet."
|
||||
::= { outletEntry 6 }
|
||||
|
||||
outletPhaseID OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
singlePhase (1),
|
||||
phase1toN (2),
|
||||
phase2toN (3),
|
||||
phase3toN (4),
|
||||
phase1to2 (5),
|
||||
phase2to3 (6),
|
||||
phase3to1 (7),
|
||||
phase12N (8),
|
||||
phase23N (9),
|
||||
phase31N (10),
|
||||
phase123 (11),
|
||||
phase123N (12)
|
||||
}
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Value indicates which phases are connected to each outlet in this table row - single phase
|
||||
voltage, phase 1 to neutral, phase 2 to neutral, phase 3 to neutral, phase 1 to phase 2,
|
||||
phase 2 to phase 3, phase 3 to phase 1, split-phase with phases 1 and 2, split phase
|
||||
with phases 2 and 3, split phase with phases 3 and 1, three-phase delta, and three-phase wye."
|
||||
::= { outletEntry 7 }
|
||||
|
||||
|
||||
|
||||
|
||||
outletParentTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF OutletParentEntry
|
||||
MAX-ACCESS not-accessible
|
||||
@ -2152,7 +2317,8 @@ outletCurrentThStatus OBJECT-TYPE
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Status of the measured outlet current relative to the configured thresholds."
|
||||
"Status of the measured outlet current relative to the configured thresholds.
|
||||
A negative value indicates that this object is not available."
|
||||
::= { outletCurrentEntry 4 }
|
||||
|
||||
outletCurrentThLowerWarning OBJECT-TYPE
|
||||
@ -2462,6 +2628,47 @@ outletControlShutoffDelay OBJECT-TYPE
|
||||
then write it to the command outletControlOffCmd."
|
||||
::= { outletControlEntry 10 }
|
||||
|
||||
|
||||
outletGlobalTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF OutletGlobalEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A list of globlal configuration on all outlets."
|
||||
::= { outlets 7 }
|
||||
|
||||
outletGlobalEntry OBJECT-TYPE
|
||||
SYNTAX OutletGlobalEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An entry for a global variable on all outlets."
|
||||
INDEX { strappingIndex
|
||||
}
|
||||
::= { outletGlobalTable 1 }
|
||||
|
||||
OutletGlobalEntry ::= SEQUENCE {
|
||||
outletAutomaticShutoff
|
||||
INTEGER
|
||||
}
|
||||
|
||||
outletAutomaticShutoff OBJECT-TYPE
|
||||
SYNTAX INTEGER {
|
||||
notApplicable (0),
|
||||
keepTheCurrentPosition (1),
|
||||
shutoffTheOutlets (2)
|
||||
}
|
||||
MAX-ACCESS read-write
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Determines the state of all outlets when the unit is power off:
|
||||
0 : not applicable (read only)
|
||||
1 : Keep the outlet relays in the current position when the PDU is powered down
|
||||
2 : Makes the outlet relays go to the position that shutoffs the outlets when the PDU is powered down"
|
||||
::= { outletGlobalEntry 2 }
|
||||
|
||||
|
||||
|
||||
temperatureTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF TemperatureEntry
|
||||
MAX-ACCESS not-accessible
|
||||
@ -2824,10 +3031,12 @@ epduOptionalGroup OBJECT-GROUP
|
||||
contactName,
|
||||
contactProbeStatus,
|
||||
contactState,
|
||||
groupChildCount,
|
||||
groupBreakerStatus,
|
||||
groupChildCount,
|
||||
groupChildOID,
|
||||
groupChildType,
|
||||
groupControl0nCmd,
|
||||
groupColor,
|
||||
groupControlOnCmd,
|
||||
groupControlOffCmd,
|
||||
groupControlRebootCmd,
|
||||
groupControlStatus,
|
||||
@ -2841,10 +3050,11 @@ epduOptionalGroup OBJECT-GROUP
|
||||
groupCurrentThStatus,
|
||||
groupCurrentThUpperCritical,
|
||||
groupCurrentThUpperWarning,
|
||||
groupDesignator,
|
||||
groupID,
|
||||
groupIndex,
|
||||
groupInputIndex,
|
||||
groupName,
|
||||
groupBreakerStatus,
|
||||
groupPowerFactor,
|
||||
groupType,
|
||||
groupVA,
|
||||
@ -2882,13 +3092,23 @@ epduOptionalGroup OBJECT-GROUP
|
||||
inputCurrentThStatus,
|
||||
inputCurrentThUpperCritical,
|
||||
inputCurrentThUpperWarning,
|
||||
inputFeedColor,
|
||||
inputFeedName,
|
||||
inputFrequency,
|
||||
inputFrequencyStatus,
|
||||
inputIndex,
|
||||
inputPhaseDesignator,
|
||||
inputPlugType,
|
||||
inputPowerCapacity,
|
||||
inputPowerCount,
|
||||
inputPowerFactor,
|
||||
inputPowerMeasType,
|
||||
inputTotalPowerFactor,
|
||||
inputTotalVA,
|
||||
inputTotalVAR,
|
||||
inputTotalWatts,
|
||||
inputTotalWh,
|
||||
inputTotalWhTimer,
|
||||
inputType,
|
||||
inputVA,
|
||||
inputVAR,
|
||||
@ -2904,16 +3124,11 @@ epduOptionalGroup OBJECT-GROUP
|
||||
inputWatts,
|
||||
inputWh,
|
||||
inputWhTimer,
|
||||
inputTotalVA,
|
||||
inputTotalWatts,
|
||||
inputTotalWh,
|
||||
inputTotalWhTimer,
|
||||
inputTotalPowerFactor,
|
||||
inputTotalVAR,
|
||||
internalStatus,
|
||||
lcdControl,
|
||||
outletControlSwitchable,
|
||||
outletControlShutoffDelay,
|
||||
outletAutomaticShutoff,
|
||||
outletControlSwitchable,
|
||||
outletControlShutoffDelay,
|
||||
outletControlOffCmd,
|
||||
outletControlOnCmd,
|
||||
outletControlPowerOnState,
|
||||
@ -2925,18 +3140,20 @@ epduOptionalGroup OBJECT-GROUP
|
||||
outletCurrent,
|
||||
outletCurrentCapacity,
|
||||
outletCurrentCrestFactor,
|
||||
outletCurrentPercentLoad,
|
||||
outletCurrentPercentLoad,
|
||||
outletCurrentThLowerCritical,
|
||||
outletCurrentThLowerWarning,
|
||||
outletCurrentThStatus,
|
||||
outletCurrentThUpperCritical,
|
||||
outletCurrentThUpperWarning,
|
||||
outletDesignator,
|
||||
outletID,
|
||||
outletIndex,
|
||||
outletName,
|
||||
outletParentCount,
|
||||
outletParentOID,
|
||||
outletParentType,
|
||||
outletPhaseID,
|
||||
outletPowerFactor,
|
||||
outletType,
|
||||
outletVA,
|
||||
@ -2955,12 +3172,12 @@ epduOptionalGroup OBJECT-GROUP
|
||||
serialNumber,
|
||||
strappingIndex,
|
||||
strappingStatus,
|
||||
systemType,
|
||||
temperatureCount,
|
||||
temperatureIndex,
|
||||
temperatureName,
|
||||
temperatureProbeStatus,
|
||||
temperatureScale,
|
||||
unitType,
|
||||
temperatureThLowerCritical,
|
||||
temperatureThLowerWarning,
|
||||
temperatureThStatus,
|
||||
@ -2971,7 +3188,8 @@ epduOptionalGroup OBJECT-GROUP
|
||||
unitControlOnCmd,
|
||||
unitName,
|
||||
unitsPresent,
|
||||
userName }
|
||||
unitType,
|
||||
userName }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Most objects in this MIB are optional."
|
||||
|
@ -6,7 +6,7 @@ IMPORTS
|
||||
TEXTUAL-CONVENTION FROM SNMPv2-TC;
|
||||
|
||||
eaton MODULE-IDENTITY
|
||||
LAST-UPDATED "201402190000Z"
|
||||
LAST-UPDATED "201811130000Z"
|
||||
ORGANIZATION "Eaton Corporation"
|
||||
CONTACT-INFO
|
||||
"Eaton Power Quality Technical Support (PQTS) group
|
||||
@ -23,6 +23,10 @@ eaton MODULE-IDENTITY
|
||||
Copyright (C) Powerware Corporation 1999-2004
|
||||
Copyright (C) Eaton Corporation (2005-)."
|
||||
|
||||
REVISION "201811130000Z"
|
||||
DESCRIPTION
|
||||
"Added assignments for eatonSensor MIB."
|
||||
|
||||
REVISION "201402190000Z"
|
||||
DESCRIPTION
|
||||
"Added assignments for stsMIB."
|
||||
@ -118,6 +122,12 @@ products OBJECT IDENTIFIER ::= {eaton 6}
|
||||
-- Defined in EATON-EPDU-MIB.txt
|
||||
-- eatonEpdu OBJECT IDENTIFIER ::= {pduAgent 7}
|
||||
|
||||
sensorAgent OBJECT IDENTIFIER ::= {products 8}
|
||||
-- sensorAgent product assignments
|
||||
-- MIB for Eaton Sensors
|
||||
-- Defined in EATON-SENSOR-MIB.txt
|
||||
-- eatonSensor OBJECT IDENTIFIER ::= {sensorAgent 1}
|
||||
|
||||
|
||||
dataCenter OBJECT IDENTIFIER ::= {products 7}
|
||||
-- dataCenter product assignments
|
||||
@ -180,3 +190,4 @@ sts OBJECT IDENTIFIER ::= {eaton 10}
|
||||
|
||||
|
||||
END
|
||||
|
||||
|
1574
mibs/eaton/EATON-SENSOR-MIB
Normal file
1574
mibs/eaton/EATON-SENSOR-MIB
Normal file
File diff suppressed because it is too large
Load Diff
@ -13,6 +13,14 @@ MG-SNMP-UPS-MIB DEFINITIONS ::= BEGIN
|
||||
-- Author: MGE UPS SYSTEMS - PV
|
||||
-- Release: V1.7 AC - Add compatibility with SMI V2
|
||||
|
||||
-- Date: December 19, 2006
|
||||
-- Author: MGE UPS SYSTEMS
|
||||
-- Release: V1.7 AD - Add traps 65 and 66 about Redundancy
|
||||
|
||||
-- Date: August 21, 2012
|
||||
-- Author: EATON POWER QUALITY
|
||||
-- Release: V1.7 AE - Add traps 67 and 68 about Protection Lost
|
||||
|
||||
IMPORTS
|
||||
enterprises,IpAddress,TimeTicks
|
||||
FROM RFC1155-SMI
|
||||
@ -2736,6 +2744,38 @@ upsmgEnvironInput2Open TRAP-TYPE
|
||||
--#SEVERITY INFORMATIONAL
|
||||
::= 64
|
||||
|
||||
-- AD Release on 2006/12/19 : Traps 65 and 66 added about redundancy.
|
||||
|
||||
upsRedundancyLost TRAP-TYPE
|
||||
ENTERPRISE upsmgTraps
|
||||
DESCRIPTION
|
||||
"Redundancy Lost."
|
||||
--#SEVERITY MAJOR
|
||||
::= 65
|
||||
|
||||
upsRedundancyOK TRAP-TYPE
|
||||
ENTERPRISE upsmgTraps
|
||||
DESCRIPTION
|
||||
"Redundancy Recovered."
|
||||
--#SEVERITY INFORMATIONAL
|
||||
::= 66
|
||||
|
||||
-- AE Release on 2012/08/21 : Traps 67 and 68 added about protection lost.
|
||||
|
||||
upsProtectionLost TRAP-TYPE
|
||||
ENTERPRISE upsmgTraps
|
||||
DESCRIPTION
|
||||
"Protection Lost."
|
||||
--#SEVERITY MAJOR
|
||||
::= 67
|
||||
|
||||
upsProtectionOK TRAP-TYPE
|
||||
ENTERPRISE upsmgTraps
|
||||
DESCRIPTION
|
||||
"Protection Recovered."
|
||||
--#SEVERITY INFORMATIONAL
|
||||
::= 68
|
||||
|
||||
|
||||
|
||||
----------------------
|
2703
mibs/eaton/XUPS-MIB
Normal file
2703
mibs/eaton/XUPS-MIB
Normal file
File diff suppressed because it is too large
Load Diff
@ -1,183 +0,0 @@
|
||||
EATON-OIDS DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
MODULE-IDENTITY, enterprises FROM SNMPv2-SMI
|
||||
Integer32 FROM SNMPv2-SMI
|
||||
TEXTUAL-CONVENTION FROM SNMPv2-TC;
|
||||
|
||||
eaton MODULE-IDENTITY
|
||||
LAST-UPDATED "201402190000Z"
|
||||
ORGANIZATION "Eaton Corporation"
|
||||
CONTACT-INFO
|
||||
"Eaton Power Quality Technical Support (PQTS) group
|
||||
www.eaton.com/powerxpert
|
||||
Technical Resource Center phone numbers
|
||||
United States: 1.800.843.9433 or 919.870.3028
|
||||
Canada: 1.800.461.9166 ext. 260
|
||||
All other countries: Call your local service representative."
|
||||
DESCRIPTION
|
||||
"Assigns major branches from the root of
|
||||
Eaton's OID tree (534).
|
||||
|
||||
Copyright (C) Exide Electronics 1992-98
|
||||
Copyright (C) Powerware Corporation 1999-2004
|
||||
Copyright (C) Eaton Corporation (2005-)."
|
||||
|
||||
REVISION "201402190000Z"
|
||||
DESCRIPTION
|
||||
"Added assignments for stsMIB."
|
||||
|
||||
REVISION "201001240000Z"
|
||||
DESCRIPTION
|
||||
"Added assignments for eatonEpdu and eatonEpduMa."
|
||||
|
||||
REVISION "200906180000Z"
|
||||
DESCRIPTION
|
||||
"Added assignments for powerCmnd and OSDCIIMIB."
|
||||
|
||||
|
||||
REVISION "200708060000Z"
|
||||
DESCRIPTION
|
||||
"Added assignments for pcdMIB and pxmMIB.
|
||||
Added common Textual Conventions for Integers."
|
||||
|
||||
REVISION "200707050000Z"
|
||||
DESCRIPTION
|
||||
"Added assignment for eatonEpduMIB.
|
||||
Cleaned up file for public consumption."
|
||||
|
||||
REVISION "200610150000Z"
|
||||
DESCRIPTION
|
||||
"Added assignments for powerChain and pxgMIB."
|
||||
|
||||
REVISION "200605250000Z"
|
||||
DESCRIPTION
|
||||
"Revised from the original assignments in XUPS-MIB.txt.
|
||||
Note that enterprises.534. was originally assigned to Exide
|
||||
Electronics before Powerware was acquired by Eaton."
|
||||
|
||||
::= { enterprises 534 }
|
||||
|
||||
-- EATON-OIDS { iso org(3) dod(6) internet(1) private(4)
|
||||
-- enterprises(1) eaton(534) }
|
||||
|
||||
|
||||
-- The Powerware "PowerMIB" for UPSs
|
||||
xupsMIB OBJECT IDENTIFIER ::= {eaton 1}
|
||||
-- Define the Environment group here since it is used in the Eaton-EMP-MIB as well
|
||||
xupsEnvironment OBJECT IDENTIFIER ::= {xupsMIB 6}
|
||||
|
||||
--
|
||||
-- The root of the list of Object Identifiers that are used to
|
||||
-- distinguish Eaton's SNMP agents (for use in sysObjId):
|
||||
xupsObjectId OBJECT IDENTIFIER ::= {eaton 2}
|
||||
powerwareEthernetSnmpAdapter OBJECT IDENTIFIER ::= {xupsObjectId 1}
|
||||
powerwareNetworkSnmpAdapterEther OBJECT IDENTIFIER ::= {xupsObjectId 2}
|
||||
powerwareNetworkSnmpAdapterToken OBJECT IDENTIFIER ::= {xupsObjectId 3}
|
||||
onlinetDaemon OBJECT IDENTIFIER ::= {xupsObjectId 4}
|
||||
connectUPSAdapterEthernet OBJECT IDENTIFIER ::= {xupsObjectId 5}
|
||||
powerwareNetworkDigitalIOEther OBJECT IDENTIFIER ::= {xupsObjectId 6}
|
||||
connectUPSAdapterTokenRing OBJECT IDENTIFIER ::= {xupsObjectId 7}
|
||||
simpleSnmpAdapter OBJECT IDENTIFIER ::= {xupsObjectId 8}
|
||||
powerwareEliSnmpAdapter OBJECT IDENTIFIER ::= {xupsObjectId 9}
|
||||
powerwareBasicEmbeddedEthernet OBJECT IDENTIFIER ::= {xupsObjectId 10}
|
||||
eatonPowerChainGateway OBJECT IDENTIFIER ::= {xupsObjectId 11}
|
||||
eatonPowerChainDevice OBJECT IDENTIFIER ::= {xupsObjectId 12}
|
||||
eatonPowerXpertMeter OBJECT IDENTIFIER ::= {xupsObjectId 13}
|
||||
|
||||
|
||||
-- Digital IO MIB (deprecated)
|
||||
-- File XUPSIOV1.MIB
|
||||
xupsIoMIB OBJECT IDENTIFIER ::= {eaton 3}
|
||||
|
||||
-- DataTrax Forseer and Powervision branch
|
||||
powerVision OBJECT IDENTIFIER ::= {eaton 4}
|
||||
|
||||
-- orphaned: BEEP (Basic Embedded Ethernet Product)
|
||||
-- File XUPS-BASIC-MIB.txt
|
||||
--xupsBasic OBJECT IDENTIFIER ::= {eaton 5}
|
||||
|
||||
-- A branch for Powerware Product MIBs
|
||||
products OBJECT IDENTIFIER ::= {eaton 6}
|
||||
-- Product assignments
|
||||
|
||||
pduAgent OBJECT IDENTIFIER ::= {products 6}
|
||||
-- pduAgent product assignments
|
||||
-- File MIB_hdpdu.mib for HD PDU
|
||||
hdpdu OBJECT IDENTIFIER ::= {pduAgent 2}
|
||||
|
||||
-- MIB for Eaton PDU, first for 9315's 3-phase PDU
|
||||
-- Defined in EATON-PDU-MIB.txt
|
||||
eatonPdu OBJECT IDENTIFIER ::= {pduAgent 4}
|
||||
|
||||
-- MIB for Eaton Powerware first-generation Managed ePDUs
|
||||
-- Defined in EATON-EPDU-MA-MIB.txt
|
||||
-- eatonEpduMa OBJECT IDENTIFIER ::= {pduAgent 6}
|
||||
|
||||
-- MIB for Eaton Powerware ePDUs
|
||||
-- Defined in EATON-EPDU-MIB.txt
|
||||
-- eatonEpdu OBJECT IDENTIFIER ::= {pduAgent 7}
|
||||
|
||||
|
||||
dataCenter OBJECT IDENTIFIER ::= {products 7}
|
||||
-- dataCenter product assignments
|
||||
environmentalMonitor OBJECT IDENTIFIER ::= {dataCenter 1}
|
||||
|
||||
|
||||
-- A branch for Eaton IT Department
|
||||
itProjects OBJECT IDENTIFIER ::= {eaton 7}
|
||||
pki OBJECT IDENTIFIER ::= {itProjects 1}
|
||||
|
||||
-- A branch for PowerChain Product MIBs
|
||||
powerChain OBJECT IDENTIFIER ::= {eaton 8}
|
||||
-- Product assignments
|
||||
|
||||
-- MIB to support Alarms and Events in PowerXpert toolkit-enabled
|
||||
-- Devices, Gateways, PXMeters
|
||||
-- Defined in file EATON-PXG-MIB.txt
|
||||
-- pxgMIB OBJECT IDENTIFIER ::= {powerChain 1}
|
||||
|
||||
-- MIB to support common measures in Power Chain Devices
|
||||
-- Defined in file EATON-PCD-MIB.txt
|
||||
-- pcdMIB OBJECT IDENTIFIER ::= {powerChain 2}
|
||||
|
||||
-- MIB to support power measures in Power Meters
|
||||
-- Defined in file EATON-PWR-MTR-MIB.txt
|
||||
-- pxmMIB OBJECT IDENTIFIER ::= {powerChain 3}
|
||||
|
||||
-- A branch for powercomand commercial control Product MIBs
|
||||
powerCmnd OBJECT IDENTIFIER ::= {eaton 9}
|
||||
|
||||
-- Product assignments
|
||||
-- MIB to support the OSDCII controller
|
||||
-- Defined in file EATON-OSDCII-MIB.txt
|
||||
-- osdcMIB OBJECT IDENTIFIER ::= {powerCmnd 1}
|
||||
|
||||
-- A branch for Eaton STS devices MIBs
|
||||
sts OBJECT IDENTIFIER ::= {eaton 10}
|
||||
|
||||
-- Product assignments
|
||||
-- MIB to support the data in STS devices
|
||||
-- Defined in file Eaton-STS.MIB
|
||||
-- stsMIB OBJECT IDENTIFIER ::= {ats 1}
|
||||
|
||||
-- Define some common Textual Conventions
|
||||
-- PositiveInteger and NonNegativeInteger are borrowed from RFC1628
|
||||
PositiveInteger ::= TEXTUAL-CONVENTION
|
||||
DISPLAY-HINT "d"
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This data type is a non-zero and non-negative value."
|
||||
SYNTAX Integer32 (1..2147483647)
|
||||
|
||||
NonNegativeInteger ::= TEXTUAL-CONVENTION
|
||||
DISPLAY-HINT "d"
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"This data type is a non-negative value."
|
||||
SYNTAX Integer32 (0..2147483647)
|
||||
|
||||
|
||||
|
||||
END
|
||||
|
2379
mibs/ups/XUPS-MIB
2379
mibs/ups/XUPS-MIB
File diff suppressed because it is too large
Load Diff
Loading…
Reference in New Issue