mirror of
https://github.com/librenms/librenms.git
synced 2024-09-28 22:06:25 +00:00
Merge pull request #1815 from laf/issue-1790
Adds basic FortiOS support
This commit is contained in:
commit
03d1d84d10
BIN
html/images/icons/appliance.png
Normal file
BIN
html/images/icons/appliance.png
Normal file
Binary file not shown.
After Width: | Height: | Size: 555 B |
BIN
html/images/os/fortios.png
Normal file
BIN
html/images/os/fortios.png
Normal file
Binary file not shown.
After Width: | Height: | Size: 22 KiB |
@ -1284,6 +1284,18 @@ $config['os'][$os]['icon'] = 'generic';
|
||||
$config['os'][$os]['over'][0]['graph'] = 'device_bits';
|
||||
$config['os'][$os]['over'][0]['text'] = 'Traffic';
|
||||
|
||||
// Appliances
|
||||
$os = 'fortios';
|
||||
$config['os'][$os]['text'] = 'FortiOS';
|
||||
$config['os'][$os]['type'] = 'appliance';
|
||||
$config['os'][$os]['icon'] = 'fortios';
|
||||
$config['os'][$os]['over'][0]['graph'] = 'device_bits';
|
||||
$config['os'][$os]['over'][0]['text'] = 'Traffic';
|
||||
$config['os'][$os]['over'][1]['graph'] = 'device_processor';
|
||||
$config['os'][$os]['over'][1]['text'] = 'CPU Usage';
|
||||
$config['os'][$os]['over'][2]['graph'] = 'device_mempool';
|
||||
$config['os'][$os]['over'][2]['text'] = 'Memory Usage';
|
||||
|
||||
// Graph Types
|
||||
require_once $config['install_dir'].'/includes/load_db_graph_types.inc.php';
|
||||
|
||||
@ -1638,6 +1650,11 @@ if (isset($config['enable_printers']) && $config['enable_printers']) {
|
||||
$config['device_types'][$i]['icon'] = 'printer.png';
|
||||
}
|
||||
|
||||
$i++;
|
||||
$config['device_types'][$i]['text'] = 'Appliance';
|
||||
$config['device_types'][$i]['type'] = 'appliance';
|
||||
$config['device_types'][$i]['icon'] = 'appliance.png';
|
||||
|
||||
//
|
||||
// No changes below this line #
|
||||
//
|
||||
|
7
includes/discovery/os/fortios.inc.php
Normal file
7
includes/discovery/os/fortios.inc.php
Normal file
@ -0,0 +1,7 @@
|
||||
<?php
|
||||
|
||||
if (!$os) {
|
||||
if (strstr($sysObjectId, '.1.3.6.1.4.1.12356.103.3')) {
|
||||
$os = 'fortios';
|
||||
}
|
||||
}
|
3
includes/polling/os/fortios.inc.php
Normal file
3
includes/polling/os/fortios.inc.php
Normal file
@ -0,0 +1,3 @@
|
||||
<?php
|
||||
|
||||
$serial = snmp_get($device, 'fnSysSerial', '-OQv', 'FORTINET-FORTIANALYZER-MIB');
|
538
mibs/FORTINET-FORTIANALYZER-MIB.mib
Executable file
538
mibs/FORTINET-FORTIANALYZER-MIB.mib
Executable file
@ -0,0 +1,538 @@
|
||||
|
||||
FORTINET-FORTIANALYZER-MIB DEFINITIONS ::= BEGIN
|
||||
|
||||
IMPORTS
|
||||
FnIndex, fnGenTrapMsg, fnSysSerial, fortinet, fnTrapsPrefix
|
||||
FROM FORTINET-CORE-MIB
|
||||
InetPortNumber
|
||||
FROM INET-ADDRESS-MIB
|
||||
sysName
|
||||
FROM SNMPv2-MIB
|
||||
MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
|
||||
FROM SNMPv2-CONF
|
||||
Counter32, Gauge32, Integer32, IpAddress, MODULE-IDENTITY,
|
||||
NOTIFICATION-TYPE, OBJECT-TYPE
|
||||
FROM SNMPv2-SMI
|
||||
DisplayString, TEXTUAL-CONVENTION
|
||||
FROM SNMPv2-TC;
|
||||
|
||||
fnFortiAnalyzerMib MODULE-IDENTITY
|
||||
LAST-UPDATED "200909210000Z"
|
||||
ORGANIZATION
|
||||
"Fortinet Technologies, Inc."
|
||||
CONTACT-INFO
|
||||
"
|
||||
Technical Support
|
||||
email: support@fortinet.com
|
||||
http://www.fortinet.com"
|
||||
DESCRIPTION
|
||||
"MIB module for Fortinet FortiAnalyzer devices."
|
||||
REVISION "200909210000Z"
|
||||
DESCRIPTION
|
||||
"Fix syntax errors."
|
||||
REVISION "200902050000Z"
|
||||
DESCRIPTION
|
||||
"Initial version of FORTINET-FORTIANALYZER-MIB."
|
||||
::= { fortinet 102 }
|
||||
|
||||
FaSessProto ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"data type for session protocols"
|
||||
SYNTAX INTEGER { ip(0), icmp(1), igmp(2), ipip(4), tcp(6),
|
||||
egp(8), pup(12), udp(17), idp(22), ipv6(41),
|
||||
rsvp(46), gre(47), esp(50), ah(51), ospf(89),
|
||||
pim(103), comp(108), raw(255) }
|
||||
|
||||
FaRAIDStatusCode ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Enumerated list of RAID status codes."
|
||||
SYNTAX INTEGER { arrayOK(1), arrayDegraded(2), arrayInoperable(3),
|
||||
arrayRebuilding(4), arrayRebuildingStarted(5),
|
||||
arrayRebuildingFinished(6), arrayInitializing(7),
|
||||
arrayInitializingStarted(8), arrayInitializingFinished(9),
|
||||
diskOK(10), diskDegraded(11), diskFailEvent(12) }
|
||||
|
||||
FaSysEventCode ::= TEXTUAL-CONVENTION
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Enumerated list of system events."
|
||||
SYNTAX INTEGER { systemHalt(1), systemReboot(2),
|
||||
upgradeConfig(3), systemUpgrade(4), logdiskFormat(5) }
|
||||
|
||||
faTraps OBJECT IDENTIFIER
|
||||
::= { fnFortiAnalyzerMib 0 }
|
||||
|
||||
faTrapPrefix OBJECT IDENTIFIER
|
||||
::= { faTraps 0 }
|
||||
|
||||
faTrapObject OBJECT IDENTIFIER
|
||||
::= { faTraps 1 }
|
||||
|
||||
faSystemEvent OBJECT-TYPE
|
||||
SYNTAX FaSysEventCode
|
||||
MAX-ACCESS accessible-for-notify
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Type of system event that triggered notification."
|
||||
::= { faTrapObject 1 }
|
||||
|
||||
faRAIDStatus OBJECT-TYPE
|
||||
SYNTAX FaRAIDStatusCode
|
||||
MAX-ACCESS accessible-for-notify
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"New RAID state associated with a RAID status change event."
|
||||
::= { faTrapObject 2 }
|
||||
|
||||
faRAIDDevIndex OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE(0..32))
|
||||
MAX-ACCESS accessible-for-notify
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Name/index of a RAID device relating to the event."
|
||||
::= { faTrapObject 3 }
|
||||
|
||||
faGenAlert OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Detail of defined event alert sent from FortiAnalyzer"
|
||||
::= { faTrapObject 4 }
|
||||
|
||||
faModel OBJECT IDENTIFIER
|
||||
::= { fnFortiAnalyzerMib 1 }
|
||||
|
||||
faz100 OBJECT IDENTIFIER
|
||||
::= { faModel 1000 }
|
||||
|
||||
faz100A OBJECT IDENTIFIER
|
||||
::= { faModel 1001 }
|
||||
|
||||
faz100B OBJECT IDENTIFIER
|
||||
::= { faModel 1002 }
|
||||
|
||||
faz100C OBJECT IDENTIFIER
|
||||
::= { faModel 1003 }
|
||||
|
||||
faz400 OBJECT IDENTIFIER
|
||||
::= { faModel 4000 }
|
||||
|
||||
faz400B OBJECT IDENTIFIER
|
||||
::= { faModel 4002 }
|
||||
|
||||
faz800 OBJECT IDENTIFIER
|
||||
::= { faModel 8000 }
|
||||
|
||||
faz800B OBJECT IDENTIFIER
|
||||
::= { faModel 8002 }
|
||||
|
||||
faz1000B OBJECT IDENTIFIER
|
||||
::= { faModel 10002 }
|
||||
|
||||
faz2000 OBJECT IDENTIFIER
|
||||
::= { faModel 20000 }
|
||||
|
||||
faz2000A OBJECT IDENTIFIER
|
||||
::= { faModel 20001 }
|
||||
|
||||
faz4000 OBJECT IDENTIFIER
|
||||
::= { faModel 40000 }
|
||||
|
||||
faz4000A OBJECT IDENTIFIER
|
||||
::= { faModel 40001 }
|
||||
|
||||
|
||||
faInetProto OBJECT IDENTIFIER
|
||||
::= { fnFortiAnalyzerMib 2 }
|
||||
|
||||
faInetProtoInfo OBJECT IDENTIFIER
|
||||
::= { faInetProto 1 }
|
||||
|
||||
faInetProtoTables OBJECT IDENTIFIER
|
||||
::= { faInetProto 2 }
|
||||
|
||||
faIpSessTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF FaIpSessEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Information on the IP sessions active on the device"
|
||||
::= { faInetProtoTables 1 }
|
||||
|
||||
faIpSessEntry OBJECT-TYPE
|
||||
SYNTAX FaIpSessEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Information on a specific session, including source and destination"
|
||||
INDEX { faIpSessIndex }
|
||||
::= { faIpSessTable 1 }
|
||||
|
||||
FaIpSessEntry ::= SEQUENCE {
|
||||
faIpSessIndex FnIndex,
|
||||
faIpSessProto FaSessProto,
|
||||
faIpSessFromAddr IpAddress,
|
||||
faIpSessFromPort InetPortNumber,
|
||||
faIpSessToAddr IpAddress,
|
||||
faIpSessToPort InetPortNumber,
|
||||
faIpSessExp Counter32
|
||||
}
|
||||
|
||||
faIpSessIndex OBJECT-TYPE
|
||||
SYNTAX FnIndex
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"An index value that uniquely identifies
|
||||
an IP session within the faIpSessTable"
|
||||
::= { faIpSessEntry 1 }
|
||||
|
||||
faIpSessProto OBJECT-TYPE
|
||||
SYNTAX FaSessProto
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The protocol the session is using (IP, TCP, UDP, etc.)"
|
||||
::= { faIpSessEntry 2 }
|
||||
|
||||
faIpSessFromAddr OBJECT-TYPE
|
||||
SYNTAX IpAddress
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Source IP address (IPv4 only) of the session"
|
||||
::= { faIpSessEntry 3 }
|
||||
|
||||
faIpSessFromPort OBJECT-TYPE
|
||||
SYNTAX InetPortNumber
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Source port number (UDP and TCP only) of the session"
|
||||
::= { faIpSessEntry 4 }
|
||||
|
||||
faIpSessToAddr OBJECT-TYPE
|
||||
SYNTAX IpAddress
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Destination IP address (IPv4 only) of the session"
|
||||
::= { faIpSessEntry 5 }
|
||||
|
||||
faIpSessToPort OBJECT-TYPE
|
||||
SYNTAX InetPortNumber
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Destination Port number (UDP and TCP only) of the session"
|
||||
::= { faIpSessEntry 6 }
|
||||
|
||||
faIpSessExp OBJECT-TYPE
|
||||
SYNTAX Counter32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Number of seconds remaining before the session expires (if idle)"
|
||||
::= { faIpSessEntry 7 }
|
||||
|
||||
fa300Compat OBJECT IDENTIFIER
|
||||
::= { fnFortiAnalyzerMib 99 }
|
||||
|
||||
faHwSensors OBJECT IDENTIFIER
|
||||
::= { fa300Compat 1 }
|
||||
|
||||
faHwSensorCount OBJECT-TYPE
|
||||
SYNTAX Integer32
|
||||
MAX-ACCESS read-only
|
||||
STATUS deprecated
|
||||
DESCRIPTION
|
||||
"The number of entries in faHwSensorTable"
|
||||
::= { faHwSensors 1 }
|
||||
|
||||
faHwSensorTable OBJECT-TYPE
|
||||
SYNTAX SEQUENCE OF FaHwSensorEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS deprecated
|
||||
DESCRIPTION
|
||||
"A list of device specific hardware sensors and values. Because different devices have different hardware sensor capabilities, this table may or may not contain any values."
|
||||
::= { faHwSensors 2 }
|
||||
|
||||
faHwSensorEntry OBJECT-TYPE
|
||||
SYNTAX FaHwSensorEntry
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS deprecated
|
||||
DESCRIPTION
|
||||
"An entry containing the name, value, and alarm status of a given hardware sensor"
|
||||
INDEX { faHwSensorEntIndex }
|
||||
::= { faHwSensorTable 1 }
|
||||
|
||||
FaHwSensorEntry ::= SEQUENCE {
|
||||
faHwSensorEntIndex FnIndex,
|
||||
faHwSensorEntName DisplayString,
|
||||
faHwSensorEntValue DisplayString,
|
||||
faHwSensorEntAlarmStatus INTEGER
|
||||
}
|
||||
|
||||
faHwSensorEntIndex OBJECT-TYPE
|
||||
SYNTAX FnIndex
|
||||
MAX-ACCESS not-accessible
|
||||
STATUS deprecated
|
||||
DESCRIPTION
|
||||
"A unique identifier within the faHwSensorTable"
|
||||
::= { faHwSensorEntry 1 }
|
||||
|
||||
faHwSensorEntName OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS deprecated
|
||||
DESCRIPTION
|
||||
"A string identifying the sensor by name"
|
||||
::= { faHwSensorEntry 2 }
|
||||
|
||||
faHwSensorEntValue OBJECT-TYPE
|
||||
SYNTAX DisplayString
|
||||
MAX-ACCESS read-only
|
||||
STATUS deprecated
|
||||
DESCRIPTION
|
||||
"A string representation of the value of the sensor. Because sensors can present data in different formats, string representation is most general format. Interpretation of the value (units of measure, for example) is dependent on the individual sensor."
|
||||
::= { faHwSensorEntry 3 }
|
||||
|
||||
faHwSensorEntAlarmStatus OBJECT-TYPE
|
||||
SYNTAX INTEGER { false(0), true(1) }
|
||||
MAX-ACCESS read-only
|
||||
STATUS deprecated
|
||||
DESCRIPTION
|
||||
"If the sensor has an alarm threshold and has exceeded it, this will indicate its status. Not all sensors have alarms."
|
||||
::= { faHwSensorEntry 4 }
|
||||
|
||||
|
||||
|
||||
fa300System OBJECT IDENTIFIER
|
||||
::= { fa300Compat 2 }
|
||||
|
||||
fa300SysSerial OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE(0..32))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Serial number of the device"
|
||||
::= { fa300System 1 }
|
||||
|
||||
fa300SysVersion OBJECT-TYPE
|
||||
SYNTAX DisplayString (SIZE(0..128))
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Firmware version of the device"
|
||||
::= { fa300System 2 }
|
||||
|
||||
fa300SysCpuUsage OBJECT-TYPE
|
||||
SYNTAX Gauge32 (0..100)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Current CPU usage (percentage)"
|
||||
::= { fa300System 3 }
|
||||
|
||||
fa300SysMemUsage OBJECT-TYPE
|
||||
SYNTAX Gauge32 (0..100)
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Current memory utilization (percentage)"
|
||||
::= { fa300System 4 }
|
||||
|
||||
fa300SysSesCount OBJECT-TYPE
|
||||
SYNTAX Gauge32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Number of active sessions on the device"
|
||||
::= { fa300System 5 }
|
||||
|
||||
fa300SysDiskCapacity OBJECT-TYPE
|
||||
SYNTAX Gauge32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Total hard disk capacity (MB), if disk is present"
|
||||
::= { fa300System 6 }
|
||||
|
||||
fa300SysDiskUsage OBJECT-TYPE
|
||||
SYNTAX Gauge32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Current hard disk usage (MB), if disk is present"
|
||||
::= { fa300System 7 }
|
||||
|
||||
fa300SysMemCapacity OBJECT-TYPE
|
||||
SYNTAX Gauge32
|
||||
MAX-ACCESS read-only
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Total physical memory (RAM) installed (KB)"
|
||||
::= { fa300System 8 }
|
||||
|
||||
|
||||
|
||||
|
||||
faMIBConformance OBJECT IDENTIFIER
|
||||
::= { fnFortiAnalyzerMib 100 }
|
||||
|
||||
faTrapSystemEvent NOTIFICATION-TYPE
|
||||
OBJECTS { fnSysSerial, faSystemEvent }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"A system event occured. The specific type of event is indecated by the faSystemEvent parameter."
|
||||
::= { faTrapPrefix 1001 }
|
||||
|
||||
faTrapRAIDStatusChange NOTIFICATION-TYPE
|
||||
OBJECTS { fnSysSerial, faRAIDStatus, faRAIDDevIndex }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Trap is sent when there is a change in the status of the RAID array, if present."
|
||||
::= { faTrapPrefix 1002 }
|
||||
|
||||
faTrapGenAlert NOTIFICATION-TYPE
|
||||
OBJECTS { fnSysSerial, fnGenTrapMsg }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Trap sent when FortiAnalyzer event parameter
|
||||
exceeds configured limit. Event description
|
||||
included in trap."
|
||||
::= { faTrapPrefix 1003 }
|
||||
|
||||
|
||||
faTrapLogRateThreshold NOTIFICATION-TYPE
|
||||
OBJECTS { fnSysSerial, sysName }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates that the incoming log rate has exceeded the configured threshold."
|
||||
::= { fnTrapsPrefix 1005 }
|
||||
|
||||
faTrapDataRateThreshold NOTIFICATION-TYPE
|
||||
OBJECTS { fnSysSerial, sysName }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Indicates that the incoming data rate has exceeded the configured threshold."
|
||||
::= { fnTrapsPrefix 1006 }
|
||||
|
||||
|
||||
|
||||
faSystemComplianceGroup OBJECT-GROUP
|
||||
OBJECTS {
|
||||
fa300SysSerial,
|
||||
fa300SysVersion,
|
||||
fa300SysCpuUsage,
|
||||
fa300SysMemUsage,
|
||||
fa300SysDiskCapacity,
|
||||
fa300SysDiskUsage,
|
||||
fa300SysMemCapacity,
|
||||
fa300SysSesCount,
|
||||
faSystemEvent
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION "System related instrumentation"
|
||||
::= { faMIBConformance 1 }
|
||||
|
||||
|
||||
faTrapsComplianceGroup NOTIFICATION-GROUP
|
||||
NOTIFICATIONS { faTrapSystemEvent, faTrapRAIDStatusChange,
|
||||
faTrapGenAlert, faTrapLogRateThreshold, faTrapDataRateThreshold }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Event notifications"
|
||||
::= { faMIBConformance 2 }
|
||||
|
||||
|
||||
faSessionComplianceGroup OBJECT-GROUP
|
||||
OBJECTS {
|
||||
faIpSessProto,
|
||||
faIpSessFromAddr,
|
||||
faIpSessFromPort,
|
||||
faIpSessToAddr,
|
||||
faIpSessToPort,
|
||||
faIpSessExp
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION "Session related instrumentation"
|
||||
::= { faMIBConformance 3 }
|
||||
|
||||
faMiscComplianceGroup OBJECT-GROUP
|
||||
OBJECTS {
|
||||
faGenAlert
|
||||
|
||||
}
|
||||
STATUS current
|
||||
DESCRIPTION "Miscellanious instrumentation"
|
||||
::= { faMIBConformance 4 }
|
||||
|
||||
faHwSensorComplianceGroup OBJECT-GROUP
|
||||
OBJECTS {
|
||||
faHwSensorCount,
|
||||
faHwSensorEntName,
|
||||
faHwSensorEntValue,
|
||||
faHwSensorEntAlarmStatus
|
||||
}
|
||||
STATUS deprecated
|
||||
DESCRIPTION "Hardware sensor related information"
|
||||
::= { faMIBConformance 5 }
|
||||
|
||||
faNotificationObjectsComplianceGroup OBJECT-GROUP
|
||||
OBJECTS { faSystemEvent, faRAIDStatus, faRAIDDevIndex }
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"Object identifiers used in notifications"
|
||||
::= { faMIBConformance 6 }
|
||||
|
||||
|
||||
|
||||
|
||||
faMIBCompliance MODULE-COMPLIANCE
|
||||
STATUS current
|
||||
DESCRIPTION
|
||||
"The compliance statement for the application MIB."
|
||||
|
||||
MODULE -- this module
|
||||
|
||||
GROUP faSystemComplianceGroup
|
||||
DESCRIPTION "System related instrumentation"
|
||||
|
||||
GROUP faSessionComplianceGroup
|
||||
DESCRIPTION
|
||||
"Session related instrumentation"
|
||||
|
||||
GROUP faMiscComplianceGroup
|
||||
DESCRIPTION "Miscellanious instrumentation"
|
||||
|
||||
GROUP faTrapsComplianceGroup
|
||||
DESCRIPTION
|
||||
"Traps are optional. Not all models support all traps. Consult product literature to see which traps are supported."
|
||||
|
||||
GROUP faNotificationObjectsComplianceGroup
|
||||
DESCRIPTION
|
||||
"Object identifiers used in notifications. Objects are required if their containing trap is implemented."
|
||||
|
||||
::= { faMIBConformance 100 }
|
||||
|
||||
|
||||
|
||||
faObsoleteMIBCompliance MODULE-COMPLIANCE
|
||||
STATUS deprecated
|
||||
DESCRIPTION
|
||||
"The compliance statement of deprecated objects for the application MIB, they may still be used by older models."
|
||||
|
||||
MODULE -- this module
|
||||
|
||||
GROUP faHwSensorComplianceGroup
|
||||
DESCRIPTION
|
||||
"Traps are optional. Not all models support all traps. Consult product literature to see which traps are supported."
|
||||
|
||||
::= { faMIBConformance 101 }
|
||||
|
||||
|
||||
END -- end of module FORTINET-FORTIANALYZER-MIB.
|
Loading…
Reference in New Issue
Block a user